Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit PG17-0144 - BOEING #9-110 - RESTROOM, DRINKING FOUNTAINS, SERVICE SINK
BOEING #9-110 9725 E MARGINAL WAY S PGI 7-0144 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov PLUMBING/GAS PIPING PERMIT 0003400018 Permit Number: PG17-0144 9725 E MARGINAL WAY S BLDG 9-110 Issue Date: 11/20/2017 Permit Expires On: 5/19/2018 Project Name: BOEING #9-110 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: BOEING COMPANY THE PO BOX 3707 M/C 20-00 PROPERTY TAX DEPT, SEATTLE, WA, 98124 CONNIE HARDIN 4600 S 134 PL , SEATTLE, WA, 98168 HOLADAY PARKS INC 4600 S 134 PL , SEATTLE, WA, 98168 HOLADPI379NO II I Phone: (206) 250-4530 Phone: (206) 248-9700 Expiration Date: 9/3/2019 DESCRIPTION OF WORK: INSTALLING 6 LAVS, 2 URINALS, 4 TOILETS, 2 FLOOR DRAINS, 2 DRINKING FOUNTAINS, 1 SERVICE SINK Valuation of Work: $25,000.00 Water District: TUKWILA Sewer District: VALLEY VIEW,TUKWILA Fees Collected: $439.10 Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Permit Center Authorized Signature: Date: /to 11 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or lo al aws-r-egul t ng construction or the performance of work. I am authorized to sign and obtain this developm; nt p:'r t ar dd .:ree ti the condi on attached to this permit. Signature: Print Name: Date: ((-—(� This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 gauge. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments 15: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 16: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 17: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 18: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 19: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 20: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 21: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 22: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 gauge. 23: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 24: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 25: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 26: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 27: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 28: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 8004 GROUNDWORK 1900 PLUMBING FINAL 8005 ROUGH -IN PLUMBING V3 / 314 0 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: //www. Tukwi 1 a W A. gov \/1-0\k/M Plumbing/Gas Permit No. `" 1 id/gig Project No. Date Application Accepted: Date Application Expires: (For o,j ice us onl 1 PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax: **Please Print** SITE LOCATION Ki Co Assessor's Tax No.: 003/460/Site Address: ! �Z���A Suite Number: Floor: Dikr.-cre T..l— f Tenant Name: CONTACT PERSON — person receiving all project communication Name:65.), �n� Je' - , 01 lie C► Address:s { AZ ! ` „[14 _W"y City: State: Zip: / /O Phone: Fax: Email: New Tenant: ❑ Yes [L}elffo PLUMBING CONTRACTOR INFO TION Company Name: fril Li. �i "fel ! Address j // obs / 7 Vkli b Ci Sta Zi / /O Phon7Z 77)'Iax: Contr Reg No Dit3' Exp Date: p Tukwila Business License No.: Valuation of Project (contractor's bid price): $ 2-(' `, ) Scope of Work (please provide detailed information): S � La 2 •r q r4,63, Building Use (per Int'l Building Code) - Occupancy (per Intl Building Code): Utility Purveyor: Water: Sewer \ApplicationsTovm-Applications On Line \201 I Applications\Plumbing Permit Application Revised 8-9-11 .doe: Revised: August 2011 bh Page 1 of 2 Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain % Shower, single head trap G�� Sinks / Rain water system — per drain (inside building) Grease interceptor for commercial kitchen (>750 gallon capacity) Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Fixture Type Qty Bidet Drinking fountain or water % cooler (per head) G�� Lavatory LP Urinal Water heater and/or vent Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial ZisoFloor Wash fountain Water closet Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers overt inch (51 mm) diameter Gas piping outlets Fixture Type Qty Dental unit, cuspidor drain ZisoFloor Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY ' THE T..AWS OF TE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDI Signature: UT 0 ZED AGE Print Name: rr.).CI Mailing Address: 14 V DD S ( 3 Pi H:1Applications\Forms-Applications On Line \2011 Applications\Plumbing Permit Application Revised 8-9-11.docx Revised: August 2011 bh Date: I 1/34 Day Telephone: ZsZ Z '.1-3 a �.� d i City 4tIState Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS I PermitTRAK ACCOUNT 1 QUANTITY PAID $439.10 PG17-0144 Address: 9725 E MARGINAL WAY S BLDG 9-110 Apn: 0003400018 $439.10 Credit Card Fee $12.79 Credit Card Fee R000.369.908.00.00 0.00 $12.79 PLUMBING $409.91 PERMIT FEE R000.322.100.00.00 0.00 $294.78 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PLAN CHECK FEE R000.322.103.00.00 0.00 $81.98 TECHNOLOGY FEE $16.40 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R12734 R000.322.900.04.00 0.00 $16.40 $439.10 Date Paid: Monday, November 06, 2017 Paid By: CONNIE HARDIN Pay Method: CREDIT CARD 08654G Printed: Monday, November 06, 2017 12:22 PM 1 of 1 CSYSTEMS INSPECTION NO. INSPECTION RECORD Retain a copy with permit /4./7-a'y� PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: Address: `772x_- /dfm M-L Date ailed: s Special Instructions: 14-P/r1BO/ /71 t. Date Wanted: 1-1 ?-./8 CD p.m. Requester: P/041) Phone No: Irj Approved per applicable codes. Corrections required prior to approval. COMMENTS: ;a ft,G — Pkt VSiA/G- Inspector: Date: 9._ 18 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 7'617- oil' Projec : 0-/ fC- 9-//0 Type of Inspection: Pi..044 ,g„. /9N0 = Address: 9725 e ; /di,L • AitY Date Called: Special Instructions: Date Wanted: --/ -le a.m. p.m. Requester: MO 0 Qtc R 5 Phone No: VS.meq-/L/4 Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: ?A 0 - RA- irGodtA Inspector: Date: _/cf REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection., INSPECTION NO. INSPECTION RECORD Retain a copy with permit r7- Digr. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Proj ct: `� %/!V — 21 Type of Inspection: P[ vm,B/x& Address: Date Called: Special Instructions: Date Wanted: a.m. o._2-11 -18 p.m. Requester: ML/PV p/4.KS fP Pg4 Phone No: 2.6.--- (??9 -/9-9,2- -i - 21 Approved per applicable codes. Corrections required prior to approval. COMMENTS: 6K- Rots6/4 p �( v e,Aw Inspector: Date REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG17-0144 DATE: 11/07/17 PROJECT NAME: BOEING #9-110 SITE ADDRESS: 9725 E MARGINAL WAY S #9-110 X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: /rS C it --9-(-7 Building Division Fire Prevention Jas A-? Public Works Structural ❑ Planning Division ❑ ❑ Permit Coordinator ❑ PRELIMINARY REVIEW: DATE: 11/07/17 Not Applicable ❑ Structural Review Required (no approval/review required) REVIEWER06 INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions DUE DATE: 12/05/17 Corrections Required ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWERo6 INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 HOLADAY PARKS INC Home Espanol Contact Search L&I Page 1 of 3 A -Z Index Help My Safety & Health Claims & Insurance Workplace Rights Trades & Licensing 0 Washington State Department of Labor & industries HOLADAY PARKS INC Owner or tradesperson BECK, DAVID CARL Principals BECK, DAVID CARL, PRESIDENT CONNELL, DANIEL A, PRESIDENT GIRI, BIJIT, PRESIDENT PIZZEY, GRACE K, VICE PRESIDENT FREEL, JERRY LEE, VICE PRESIDENT PARKS, GERALD T JR, PRESIDENT (End: 08/12/2015) NAILON, JUNE ANNETTE, VICE PRESIDENT (End: 08/12/2015) O'CONNOR, BONNY K, SECRETARY (End: 08/12/2015) BECK, DAVID CLARENCE, TREASURER (End: 08/12/2015) VAN DER VEEN, ERIC M, VICE PRESIDENT (End: 08/14/2013) PIZZEY, GRACE KATHERINE, VICE PRESIDENT (End: 08/14/2013) VAN DER VEEN, JULIE ELIZABETH, MEMBER (End: 08/14/2013) CONNELL, DANIEL AARON, MEMBER (End: 08/14/2013) GIRI, BUIT, MEMBER (End: 08/14/2013) KIEL, RINALD HOWARD, MEMBER (End: 08/14/2013) WHITMYRE, CHRISTIAN, MEMBER (End: 08/14/2013) NELSON, MICHAEL, SECRETARY (End: 11/04/2010) PARKS, DAVID L, TREASURER (End: 11/04/2010) TALBOT, PAUL, TREASURER (End: 11/04/2010) WA UBI No. 578 004 089 4600 S 134TH PL SEATTLE, WA 98168 206-248-9700 KING County Business type Corporation License Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=578004089&LIC=HOLADPI379N0&SAW= 11/17/2017 HOLADAY PARKS INC Verify the contractor's active registration / licen Construction Contractor License specialties GENERAL License no. HOLADPI379NO Effective — expiration 01/2111983— 09/03/2019 Bond LIBERTY MUTUAL INS CO Bond account no. 23000452 ?rtification (depending on trade) and any past violations Active. Meets current requirements. $12,000.00 Received by L&I Effective date 08/23/2002 09/01/2002 Expiration date Until Canceled Insurance Charter Oak Fire Ins Co Policy no. DTCO1 F465357C0F17 $1,000,000.00 Received by L&I Effective date 10/31/2017 11/01/2017 Expiration date 11/01/2018 Insurance history Savings ................ No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID Account is current. 177,231-00 Doing business as HOLADAY PARKS INC Estimated workers reported Quarter 3 of Year 2017 "Greater than,100 Workers" L&I account contact T4 / CASSANDRA SMITH (360)902-5632 - Email: SMCA235©Ini.wa.gov Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 09/22/2016 Inspection no. No violations Page 2 of 3 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=578004089&LIC=HOLADPI379N0&SAW= 11/17/2017 VICI\ITY NAP PROJECT SITE FROM DOWNTOWN SEATTLE 900 99 EXIT 158 EXIT 157 99 EAST MARGINAL WAY CORPORATE PARK FROM SEATTLE -TACOMA AIRPORT DEVELC D 599 TUKWILA \/E\TAL CE\ITH FROM KENT Sc AUBURN NO SCALE 900 BOEING WORKPLACE SERVICES BUILDING 9-110 OFFICE TENANT IMPROVEMENT #34424 BOEING DEVELOPMENTAL CENTER 9725 EAST MARGINAL WAY SOUTH TUKWILA, WASHINGTON 98108 A EA V AP 3UILD1\G ADDESS: 9725 EAST VAGI\AL WAY SOUTH TU<WILA, WASHI\GTO\ PROJECT SITE It COPY VG1-7- ['ALI is a :;tO icm d of any adopted code and omissi& not authorize ordinance. Receipt acknowledged: 0 Date: 1 J --I City of Tukwila BUILDING DIVISION 9-110 3UILDI \G LO CAT SEPARATE PERMIT R QUIREU FOR: CgdViechanical tectricai 0 F,Limbing i2Gas Piping City of Tukwila BUILDING DIVISION 0\ NO SCALE GE \RAL \CIES CONSTRUCTION SET OF DOCUMENTS, REVIEWED AND STAMPED BY CITY OF TUKWILA MUST BE ON SITE DURING CONSTRUCTION. DO NOT PROCEED WITH CONSTRUCTION WITHOUT ABOVE MENTIONED SET OF DOCUMENTS. 1. VERIFY ALL DIMENSIONS AND CONNECTIONS BEFORE ANY WORK. 2. NOTIFY FACILITY ENGINEERS SHOULD EXISTING CONDITIONS REQUIRE DESIGN REVISIONS. 3. COORDINATE WORK WITH OTHER CRAFTS. 4. RETURN THIS SAME SET TO JOHN MURDOCH AT BUILDING .D9-051.2 COLUMN M/2, AFTER COMPLETION OF THIS CONSTRUCTION. REVISIONS No chances shall be made to the scope of work without prior approval of Tut(r•Jila Building Division. 1 f' O T Z-: F;svisic ns will require a new plan submittal I and may include additional plan review fees. 1 SCOPE OF WO INTERIOR TENANT IMPROVEMENT OF APPROXIMATELY 8,636 SF OF EXISTING OFFICE AREA. INCLUDES DEMOLITION OF NON -LOAD BEARING WALLS, RESTROOM RENOVATIONS, KITCHENLIIE, AND REPLACEMENT OF FLOOR FINISHES, ACOUSTICAL CEILING TILES, AND PAINTING THROUGHOUT, WITH MINOR ELECTRICAL AND MECHANICAL MODIFICATIONS. THERE WILL BE NO CHANGES TO THE EXISTING BUILDING CONSTRUCTION TYPE OR OCCUPANCY GROUP CLASSIFICATION. THE OCCUPANT LOAD HAS BEEN INCREASED DUE TO THE ADDITION OF A CONFERENCE ROOM - REFER TO THE EXITING PLAN FOR THE EXITING SYSTEM. CODE SUN vAY LAND USE CODE BUILDING CODES TUKWILA 2015 I.B.C., U.F.C., U.P.C., AND THE WAC 51-20 AS ADAPTED OR AMENDED BY LOCAL ORDINANCES, AND COMPLIANCE WITH CITY OF TUKWILA ZONING. OCCUPANCY GROUP GROUP B (OFFICE) CONSTRUCTION TYPE FLOOR AREAS: BUILDING FOOTPRINT, GROSS AND FIRST FLOOR BUILDING HEIGHT STORIES OCCUPANT LOAD: HANDICAPPED REQUIREMENTS FIRE PROTECTION SEISMIC ZONE TYPE VB SEPARATION 60 FEET (MINIMUM THREE SIDES) 8,636 S.F. 18 FT. 1 SEE 1A01 FOR EXITING PLAN ARCHITECT'S INTENT: FOR 2015 IBC WORK DESIGN WILL MAINTAIN EXISTING LIKE KIND MATERIALS AND ASSEMBLIES PER 97 UBC REQUIREMENTS. BARRIER FREE FULLY AUTOMATIC, F/S CLASS 1 SPRINKLERS THROUGHOUT 3 DAWI\G I\DEX SHEET NO. DRAWING NO. SHEET TITLE REV NO. DATE GO 9 -110 -GO TITLE SHEET - 10.31.17 Al 9-110-A1 GENERAL ARCHITECTURAL NOTES AND CODE SUMMARY - 10.31.17 1A01 9-110-1A01 FIRST FLOOR EXITING PLAN C 10.31.17 1 Al OR 9-110-1 Al OR FLOOR PLAN - REMOVAL - 10.31.17 1A10 9-110-1A10 FLOOR PLAN F 10.31.17 1A280R 9-110-1A280R REFLECTED CEILING PLAN - REMOVAL - 10.31.17 1A280 9-110-1A280 REFLECTED CEILING PLAN - 10.31.17 1A450 9-110-1A450 ENLARGED FLOOR PLANS - 10.31.17 1A451 9-110-1A451 ENLARGED FLOOR PLANS - 10.31.17 A350 9-110-A350 SCHEDULES - 10.31.17 A371 9-110-A371 INTERIOR ELEVATIONS - 10.31.17 A372 9-110-A372 INTERIOR ELEVATIONS - 10.31.17 A504 9-110-A504 MISC SECTIONS AND DETAILS - 10.31.17 A505 9-110-A505 MISC SECTIONS AND DETAILS - 10.31.17 A506 9-110-A506 MISC SECTIONS AND DETAILS - 10.31.17 A507 9-110-A507 MISC SECTIONS AND DETAILS - 10.31.17 M 1 R 9-110-M 1 R SCHEDULES - REMOVAL B 10.31.17 1 M1 OR 9-110-1 M1 OR HVAC FIRST FLOOR PLAN - REMOVAL E 10.31.17 1 M11 OR 9-110-1 M11 OR PLUMBING PLAN - REMOVAL C 10.31.17 M450R 9-110-M450R PARTIAL PLAN - REMOVAL A 10.31.17 RFM1OR 9-110-RFM1OR HVAC ROOF PLAN - REMOVAL A 10.31.17 M1 9-110-M1 SCHEDULES B 10.31.17 1M10 9-110-1M10 HVAC FIRST FLOOR PLAN E 10.31.17 1M110 9-110-1M110 PLUMBING PLAN B 10.31.17 1M260 9-110-1M260 FIRE PROTECTION FIRST FLOOR PLAN D 10.31.17 M450 9-110-M450 PARTIAL PLAN A 10.31.17 RFM 10 9-110-RFM 10 HVAC ROOF PLAN A 10.31.17 E4R 9-110-E4R ONE LINE DIAGRAM - REMOVAL A 10.31.17 1 E1 OR 9-110-1 E1 OR LIGHTING FLOOR PLAN - REMOVAL E 10.31.17 1E6OR 9-110-1E6OR 120/208 VAC PLAN - REMOVAL M 10.31.17 1 E41 OR 9-110-1 E41 OR NETWORK PLAN - REMOVAL - 10.31.17 E4 9-110-E4 ONE LINE DIAGRAM G A 10.31.17 REVIEWED FOR 1E10 9-110-1E10 LIGHTING FLOOR PLAN CODE COMPLIANCE APPROVED E 10.31.17 1E60 9-110-1E60 120/208 VAC PLAN � NOV 14 2011 M 10.31.17 1E410 9-110-1E410 NETWORK PLAN kl- x City I ttl '{la - 10.31.17 E501 9-110-E501 MISCELLANEOUS DETAILS of 13U1 ' k ' ` A 10.31.17 E5XX 9-110-E5XX LIGHTING DETAILS - 10.31.17 j RECEIVED CITY OF TUKWILA t`J p 6 2017 PERMIT CENTER 90% DESIGN REVIEW OCTOBER 31, 2017 SITTS & HILL ENGINEERS, INC. CIVIL • STRUCTURAL • -SURVEYING 4815 CENTER STREET I TACOMA, WA. 98409 PHONE: (253) 474-9449 1 FAX: (253) 474-9449 http://www.sitts-hill-engineers.com/ Project No.: 18002 Project Mgr.: BKL Proj. Engineer. DCB Proj. Drafter: LAM SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE EXTRS: RELOCATE IR SIGN LAB (21-01) J#190105-02 GMM 09.20.00 RELOCATE OS1 TO 9-110 J#120706-02 GMM 10.22.02 RELOCATE OS1 TO 9-110 (CONSTRUCTION) J#120706-02 GMM 10.30.02 ADD GATES Ar41S1 FENCE J#545680-02 GMM 04.30.04 OFFICE TENANT IMPROVEMENT 34224. SITTS BKL. 10.31.17 0:Lim.Efir.e.mv”° ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN G.MILLER DATE CHECKED SUBTITLE TITLE SHEET CURRENT REVISION 34224 SYMBOL DATE 10.31.17 ENGINEER G.MILLER CHECKED 09.20.00 APPROVED APPROVED TITLE OFFICE TENANT IMPROVEMENT ARCHITECTURAL MASTER BUILDING 9-110 DEV. CENTER, WA SHEET GO JOB NO. COMP NO. DWG NO. 09 -110 -GO DUARTEE: 9/26/2013 6:17:46 AM DOCUNINT C 'PALLETPA 1. 40X,23„ 40X,23 iDELTA I 12 PLUGGED OULET %2' PLU GED OU 1" PLUGGED OULET Iry HI -ROSS COOLING UNIT ELECTRICAL BALL LVE 1" GAS UP R - OOR Vit J -XX FIST FLOO PLA\ SCALE: 1/8"=1 —0" SEE ENLARGE PLAN ON SHEET M450R REMOVAL -1 90% SUBMITTAL OCTOBER 31, 2017 LEGE\J GE EAL \OTES EFEE\ CE DAWI\;S EvOVAL. \ orfs REMOVE AIR PIPING, AND SUPPORTS BACK TO ISOLATION VALVE IN MECHANICAL ROOM. SHUT ISOLATION VALVE AND PROVIDE CAP. REMOVE AIR COMPRESSOR. RECEIVED CITY OF TUKVVILA NOV p 6 2017 PERMIT CENTER 0 4 REVIEWED FOR CODE COMPLIANCE APPROVED NOV 14 2011 City o TukwIIa BUIL IN9 DIVISION 8 16 24 ■ ■EM NI NI,.;MEI SCALE: 1/8"= 1 '-0" FSi consulting engineers Seattle, Washington Solutions & Service REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE IR SIGNATURE LAB J#190105-02 C HARRAH RWS 10.29.00 REMOVE PLUMBING LINES J#120706-02 DMV 9-110 DENSIFICATION 34224 FSi AWL 10.31.17 10.29.02 Q�BOE/NG° �y- ACC EPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DRAWN K BUN CHECKED C HARRAH DATE 9.20.00 10.29.00 SUBTITLE PLUMBING PLAN CURRENT REVISION 34224 SYMBOL 3 DATE 10.31.17 TITLE 9-110 DENSIFICATION CHECKED BUILDING 9-110 10.31.17 VP 1) APPROVED MECHANICAL MASTFR COL. A—DD / 1-4 D.0 DWG NO. 120706-02 COMP NO. 9-110-1M11OR (1 CC REMOVAL LEGE\D CE\HAL \OTES 1. ASBESTOS NOTIFICATION: A GOOD FAITH SURVEY OF THE WORK AREA HAS BEEN CONDUCTED AND ASBESTOS CONTAINING MATERIAL WAS NOT DISCOVERED THAT WOULD BE INVOLVED IN THE CONSTRUCTION OF THIS PROJECT. DO NOT REMOVE, DAMAGE OR DISTURB ANY ASBESTOS MATERIAL ADJACENT TO THE WORK AREA. PLEASE CONTACT BOEING FACILITIES DEPARTMENT IF ASBESTOS CONTAINING MATERIAL IS DAMAGED OR DISCOVERED THAT IS REQUIRED TO BE REMOVED TO SUPPORT WORK. THE FOLLOWING MATERIALS IN THE AREAS ADJACENT TO THIS JOB ARE ASSUMED TO BE POSITIVE FOR ASBESTOS: 1. FLOOR TILE AND MASTIC (12" x 12" WHITE) 2. CARPET MASTIC 3. FIRE DOOR INSULATION vOVAL \OTES REMOVE LAV, FAUCET, STOPS AND WASTE PIPE BACK TO MAIN. REMOVE WATER CLOSET, VENT TO ROOF AND WASTE PIPING BACK TO MAIN. REMOVE URINAL, VENT TO ROOF AND WASTE PIPING BACK TO MAIN. REMOVE DRINKING FOUNTAIN, VENT TO ROOF AND WASTE PIPING BACK TO MAIN. DEMO DOMESTIC COLD WATER, DOMESTIC HOT WATER, VENT AND SANITARY FROM PLUMBING CHASE. 90% SUBMITTAL OCTOBER 31, 2017 4' REVIEWED FOR CODE COMPLIANCE APPROVED NOV 14211 CI' of Tu to BUIDI# DLV . RECEIVED CITY OF TUKWILA NOV o 6 2017 PERMIT CENTER 2' 0 2' 4' 8' SCALE: 1/4"=1'-0" FSi consulting engineers Seattle, Washington Solutions & Service SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE A 9-110 DENSIFICATION 34224 FSi AWL 10.31.17 Q� BOE/NG° 10.31.17 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN D. VILLA DATE CHECKED SUBTITLE PARTIAL PLAN CURRENT REVISION 34224 SYMBOL A DATE 10.31.17 APPROVED BY DEPT. DATE ENGINEER D. VILLA 09.20.00 CHECKED APPROVED APPROVED TITLE MECHANICAL MAgTrR 9-110 DENSIFICATION BUILDING 9-110.1 COL. P—CC/4 D SHEET M450R JOB NO. 34224 COMP NO. DWG NO. 9-110—M450R 'PALLET R K "PALE" RACK 4QX123„ 40x123, HI -ROSS COOLING UNIT LEGE\ D GE\HAL \OTES EFE E\CE NAM \GS CO\STUCTO\. \OTES ELECTRICAL PROVIDE 1/2" CW CONNECTION TO COFFEE MAKER. COORDINATE LOCATION WITH ARCHITECT. koj3 J -XX 1" GAS UP THRU FLOOR FIST FL0ICH PLA\ SCALE: 1/8"=1 —0" SEE ENLARGE PLAN ON SHEET M450 90% SUBMITTAL OCTOBER 31, 2017 REVIEWED FOR CODE COMPLIANCE APPROVED NOV 14 2017 • City of Tukwila BUILDINt D!y SIO RECEIVED ,IT' QF tJ(V'11L'' NOV 06 217 0 4 8 16 24 ■£ ■,=Irf� ■ ■ = FY SCALE: 1 /8"=1'-0" • FSi consulting engineers Seattle, Washington Solutions & Service SYM A REVISION B C IR SIGNATURE LAB J#190105-02 REMOVE PLUMBING LINES J#120706-02 9-110 DENSIFICATION 34224 BY C HARRAH DMV FSi APPROVED DATE SYM REVISION BY APPROVED DATE RWS 10.29.00 AWL 10.31.17 10.29.02 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DRAWN K BUN DATE 9.20.00 SUBTITLE 10.29.00 PLUMBING PLAN DATE TITLE CHECKED BUILDING 9-110 10.31.17 APPROVED MECHANICAL MASTER COL. A—DD / 1-4 D.C. CURRENT REVISION 34224 SHEET JOB NO. DWG NO. SYMBOL 1 M1 1 0 120706-02 3 DATE 10.31.17 COMP NO. 9-110-1M110 PLUV 3I\G FIXTURE SCHEDULE MARK FIXTURE DESCRIPTION BRANCH PIPE SIZE — INCHES DIA. : ADDITIONAL COMPONENTS BASIS OF - DESIGN REMARKS COLD WATER HOT WATER WASTE VENT MANUFACTURER MODEL LAV -1 COUNTERTOP—MOUNTED LAVATORY 1/2" 1/2" 1 1/2" 1 1/4" FAUCET: CHICAGO 116.606.AB.1, GRID STRAINER AMERICAN STANDARD 9482.000 WC -1 WALL—HUNG WATER CLOSET WITH FLUSH VALVE, ADA 1" — 3" 1 1/2" SLOAN ROYAL OPTIMA SMO MODEL 111 FLUSH VALVE; MIN. SEAT HEIGHT AT 17" FOR ADA ACCESSIBLE INSTALLATION, CARRIER J.R. SMITH KOHLER K-4323 ADJUSTABLE HEIGHT CARRIER SHALL BE SET FOR H/C OR STD. OPEN FRONT SEAT LESS COVERT. UR -1 WALL—HUNG URINAL WITH FLUSH VALVE, ADA 3/4" — 2" 1 1/2" SLOAN ROYAL OPTIMA SMO MODEL 186-1 FLUSH VALVE; CARRIER J.R. SMITH KOHLER K-5016—ET FD -1 FLOOR DRAIN — — 2" 1 1/2" NO HUB ROUND TOP, 1/2" TRAP PRIMER CONNECTION JAY R. SMITH 2005Y-050 SS -1 SERVICE SINK 3/4" 3/4" 3" 1 1/2". FAUCET: CHICAGO 897—CP MUSTEE 63M WITH REMOVABLE VINYL COATED RIM GUARD LEGE\D GE\RAL \OTES 1. ASBESTOS NOTIFICATION: A GOOD FAITH SURVEY OF THE WORK AREA HAS BEEN CONDUCTED AND ASBESTOS CONTAINING MATERIAL WAS NOT DISCOVERED THAT WOULD BE INVOLVED IN THE CONSTRUCTION OF THIS PROJECT. DO NOT REMOVE, DAMAGE OR DISTURB ANY ASBESTOS MATERIAL ADJACENT TO THE WORK AREA. PLEASE CONTACT BOEING FACILITIES DEPARTMENT IF ASBESTOS CONTAINING MATERIAL IS DAMAGED OR DISCOVERED THAT IS REQUIRED TO BE REMOVED TO SUPPORT WORK. THE FOLLOWING MATERIALS IN THE AREAS ADJACENT TO THIS JOB ARE ASSUMED TO BE POSITIVE FOR ASBESTOS: 1. FLOOR TILE AND MASTIC (12" x 12" WHITE) 2. CARPET MASTIC 3. FIRE DOOR INSULATION CO\ S-RUCTIO\ \OTES CONNECT SEWER LINE TO EXISTING OUTSIDE OF RESTROOM. ROUTE COLD WATER, HOT WATER, WASTE AND VENT PIPING TO JANITORS SINK. ROUTE COLD WATER, WASTE AND VENT PIPING TO DRINKING FOUNTAINS. PROVIDE CONNECTION TO PLUMBING FIXTURES. SEE FIXTURE SCHEDULE FOR SIZE. PROVIDE FLOOR DRAIN AND CONNECT TO SANITARY MAIN. 90% SUBMITTAL OCTOBER 31, 2017 4' 2' REVIEWED FOR CODE COMPLIANCE APPROVED NOV 14 2011 City of Tukwila BUILISl N REGEIV EC) CITY OF TUKWILA tOV p 6 2017 PERMIT CENTER 0 2' 4 8' SCALE: 1 /4"=1 '-0" • FSi consulting engineers Seattle, Washington Solutions & Service SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE A 9-110 DENSIFICATION 34224 FSi AWL 10.31.17 E rr- ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DRAWN D. VILLA CHECKED ENGINEER D. VILLA DATE SUBTITLE CURRENT REVISION PARTIAL PLAN SYMBOL 34224 TITLE 9-110 DENSIFICATION 10.31.17 APPROVED MECHANICAL MASTER BUILDING 9-110.1 COL. P—CC/4 D.0 DWG NO. 34224 DATE 10.31.17 COMP NO. 9-110—M450