Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D18-0350 - STERLING SOUTHCENTER- SALES OFFICE - MARKETING CENTER
STERLING SOUTHCENTER- SALES OFFICE 406 BAKER BLVD 160 D18-0350 Parcel No: Address: Project Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 0223100037 406 BAKER BLVD 160 STERLING SOUTHCENTER- SALES OFFICE Permit Number: Issue Date: Permit Expires On: D18-0350 12/10/2018 6/8/2019 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: EILAT MANAGEMENT 650 S ORCAS ST #210 ICG REALTY LLC, SEATTLE„ 98104 ALEX DALZELL Phone: (206) 676-5649 ALLIANCE PACIFIC NW BLDRS LLC Phone: (206) 330-0618 2525 E CAMELBACK ROAD SUITE 500, PHOENIX, AZ, 85016 ALLIAPN871LK Expiration Date: 6/12/2019 1938 FAIRVIEW AVE E, SUITE 100 , , , NATIONAL BANK OF ARIZONA 6001 NORTH 24TH STREET, PHOENIX, AZ, 85016 DESCRIPTION OF WORK: THIS IS FOR A TENANT IMPROVEMENT PERMIT TO REFINISH AN EXISTING SPACE TO MAKE A MARKETING CENTER. THE SCOPE INCLUDES; DEMOLITION OF EXISTING INTERIOR WALLS, NEW INTERIOR PARTITIONS, NEW FLOOR FINISHES, ELECTRICAL OUTLET LOCATION REVISIONS. Project Valuation: $120,000.00 Type of Fire Protection: Sprinklers: YES Fire Alarm: YES Type of Construction: VB Electrical Service Provided by: TUKWILA Fees Collected: $3,029.12 Occupancy per IBC: B Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: IOC Date: 12 � " fl_/ I hearby certify that I have read and examined is permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regul ing construction or the performance of work. I am authorized to sign and obtain this development per d agree to thditions attached to this permit. SignaturN. Print Name: C.�,...v Date: ) Z7/61/ This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: New suspended ceiling grid and light fixture installations shall meet the seismic design requirements for nonstructural components. ASCE 7, Chapter 13. 5: Partition walls shall not be tied to a suspended ceiling grid. All partitions greater than 6 feet in height shall be laterally braced to the building structure. Such bracing shall be independent of any ceiling splay bracing. 6: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 7: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 8: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 9: Every occupied space other than enclosed parking garages and buildings used for repair of automobiles shall be ventilated in accordance with the applicable provisions of the International Mechanical Code. 10: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 11: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 12: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 13: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 17: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 14: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 15: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 16: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 7.2, 7.3) 18: Maintain fire extinguisher coverage throughout. 19: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1010.1.9) 20: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 21: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 22: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1010.1.9.1) 26: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards. (IFC 901.4) 24: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA 13-8.6.5.3.3) /� � J n 23: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 27: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #2437. 29: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 28: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 30: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 31: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.11 of the International Building Code. 32: In order to provide you with the fastest police and fire protection under emergency conditions, please post your suite, room or apartment number in a conspicuous place near the main entry door. 25: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 33: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 34: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 1400 FIRE FINAL 0409 FRAMING 0606 GLAZING 0406 SUSPENDED CEILING CITY OF TUK( LA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TulcwilaWA.gov Building Permit No. 1 (� " (2 3,5-0 Project No. Date Application Accepted: 11— J� _ l U Date Application Expires: IT - 19 (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 406 Baker Boulevard Tenant Name: Marvelle at Southcenter - Sales Office King Co Assessor's Tax No.: 0223100037 Suite Number: 160 Floor: N/A PROPERTY OWNER Name: Alex Dalzell Name: ICG Realty, LLC City: Seattle State: WA Zip: 98102 Address: 650 S. Orcas St, Suite 210 Email: alexd@urbalarchitecture.com City: Seattle State: WA Zip: 98108 CONTACT PERSON — person receiving all project communication Name: Alex Dalzell Address: 1938 Fairview Ave W Suite 100 City: Seattle State: WA Zip: 98102 Phone: (206) 676-5649 Fax: Email: alexd@urbalarchitecture.com GENERAL CONTRACTOR INFORMATION Company Name: Alliance Pacific Northwest Builders Address: 1325 4 th Ave Suite 1005 City: Seattle State: WA Zip: 98101 Phone: (206) 330-0618 Fax: Contr Reg No.: ALLIAPN871LK Exp Date: 06/12/2019 Tukwila Business License No.: BUS -0998381 H:4lpplications\Forms-Applications On Line\2011 Applications\Permit Application Revised - 8-9-1 I.docx Revised: August 2011 bh New Tenant: ❑ Yes ..No ARCHITECT OF RECORD Company Name: Urbal Architecture Architect Name: Chad Lorentz Address: 1938 Fairview Ave W, Suite 100 City: Seattle State: WA zip: 98102 Phone: (206) 257-0972 Fax: Email: chadl@urbalarchitecture.com ENGINEER OF RECORD Name: National Bank of Arizona Address: 6001 North 24th Street Company Name: Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: National Bank of Arizona Address: 6001 North 24th Street City: Phoenix State: AZ Zip: 85016 Page 1 of 4 BUILDING PERMIT INFORMATI(- 206-431-3670 sine Valuation of Project (contractor's bid price): $ 120,000 Describe the scope of work (please provide detailed information): This for a tenant improvement permit to refinish an existing space to make a marketing center. The scope includes; demolition of existing interior walls, new interior partitions, new floor finishes, electrical outlet location revisions Existing Building Valuation: $ Will there be new rack storage? 0 Yes VI.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ill No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: None of the fire protection features are going to be altered 121 Sprinklers ® Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flanunable, combustible or hazardous materials in the building? ❑ Yes 171 No If `yes ; attach list of materials and storage locations on a separate 8-1/2"x 11 "paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Fonns-Applications On Line\2011 Applic tions\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1a Floor 15,740 2,498 Type VA B rd Floor 3`d Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ill No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: None of the fire protection features are going to be altered 121 Sprinklers ® Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flanunable, combustible or hazardous materials in the building? ❑ Yes 171 No If `yes ; attach list of materials and storage locations on a separate 8-1/2"x 11 "paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Fonns-Applications On Line\2011 Applic tions\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of 4 PUBLIC WORKS PERMIT INFO ON — 206-433-0179 Scope of Work (please provide detailed information): No Utility revisions are in the scope Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ..• .Tukwila ❑ ...Water District #125 O ...Water Availability Provided Sewer District 0 ...Tukwila O ...Sewer Use Certificate ❑ .. Highline ❑...Valley View 0 .. Renton ❑ ... Sewer Availability Provided ❑ .. Renton ❑ .. Seattle Septic System: O On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): 0 ...Civil Plans (Maximum Paper Size — 22" x 34") ❑ ...Technical Information Report (Storm Drainage) O ...Bond 0 .. Insurance 0 .. Easement(s) Proposed Activities (mark boxes that apply): ❑ ...Right-of-way Use - Nonprofit for less than 72 hours 0 ...Right-of-way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right-of-way ❑ Non Right-of-way 0 ❑ ...Total Cut ❑ ...Total Fill cubic yards cubic yards ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities 0 ...Frontage Improvements ❑ ...Traffic Control O ...Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ .. Geotechnical Report O .. Maintenance Agreement(s) ❑ ...Traffic Impact Analysis ❑ ...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) ❑ .. Right-of-way Use - Profit for less than 72 hours ❑ .. Right-of-way Use — Potential Disturbance O .. Work in Flood Zone ❑ .. Storm Drainage ❑ .. Abandon Septic Tank ❑ .. Curb Cut O .. Pavement Cut ❑ .. Looped Fire Line ❑ ...Permanent Water Meter Size... WO # ❑ ...Temporary Water Meter Size .. WO # ❑ ...Water Only Meter Size WO # ❑ ...Sewer Main Extension Public 0 Private 0 ❑ ...Water Main Extension Public 0 Private 0 0 .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding 0 ...Deduct Water Meter Size 91 FINANCE INFORMATION Fire Line Size at Property Line O ...Water 0 ...Sewer 0 ...Sewage Treatment Monthly Service Billing to: Name: Number of Public Fire Hydrant(s) Day Telephone: Mailing Address: City State Zip Water Meter Refund/Billing: Name: Day Telephone: Mailing Address: City State Zip H:Applications \Forms -Applications On Line\2011 Applications\Public Works Permit Application Revised 8-9-11.docx Revised: May 2011 bh Page 2 of 3 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0` ' OR AU 1 ORIZED AGENT: Signature: Date: (! /2/ cd Print Name:`v T) L� � — Day Telephone: Z c C1 — 23-7-0117 Z G Mailing Address: (-1Si Pk%lew Ave- F LA% o SEATTLE tAlk 11002. City H:\ Applications\Forms-Applications On Line \2011 Applications\Pertnit Application Revised - 8-9-11.docx Revised: August 2011 bh State Zip Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK J ACCOUNT 1 QUANTITY I PAID $1,880.77 D18-0350 Address: 406 BAKER BLVD 160 Apn: 0223100037 $1,880.77 Credit Card Fee $54.78 Credit Card Fee R000.369.908.00.00 0.00 $54.78 DEVELOPMENT $1,740.23 PERMIT FEE R000.322.100.00.00 0.00 $1,715.23 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $25.00 TECHNOLOGY FEE $85.76 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R15999 R000.322.900.04.00 0.00 $85.76 $1,880.77 Date Paid: Friday, December 07, 2018 Paid By: JAMES WANDER Pay Method: CREDIT CARD 07771D Printed: Friday, December 07, 2018 3:40 PM 1 of 1 SYSTEMS CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA 0017340000802374464500 Date: 12/07/2018 03:39:25 PM CREDIT CARD SALE VISA CARD NUMBER: **********7272 K TRAN AMOUNT: $1,880.77 APPROVAL CD: 07771D RECORD #: 000 CLERK ID: Bill X {CARDHOLDER'S SIGNATURE} I AGREE TO PAY THE ABOVE TOTAL AMOUNT ACCORDING TO THE CARD ISSUER AGREEMENT (MERCHANT AGREEMENT IF CREDIT VOUCHER) Thank you! Merchant Copy Page 1 of 2 https://classic.convergepay. com/V irtualMerchant/transaction.do?dispatchMethod=printTra... 12/7/2018 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT , QUANTITY PAID $1,148.35 D18-0350 Address: 406 BAKER BLVD 160 Apn: 0223100037 $1,148.35 Credit Card Fee $33.45 Credit Card Fee R000.369.908.00.00 0.00 $33.45 DEVELOPMENT $1,114.90 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R15760 R000.345.830.00.00 0.00 $1,114.90 51,148.35 Date Paid: Monday, November 05, 2018 Paid By: EVAN LAWLER Pay Method: CREDIT CARD 06862D Printed: Monday, November 05, 2018 8:11 AM 1 of 1 SYSTEMS CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA Date: 11/05/2018 08:10:46 AM CREDIT CARD SALE VISA CARD NUMBER: **********9668 K TRAN AMOUNT: $1,148.35 APPROVAL CD: 06862D RECORD #: 000 CLERK ID: Bill Thank you! Customer Copy Page 2 of 2 https://classic. convergepay.com/VirtualMerchant/transaction.do?dispatchMethod=printTra... 11/5/2018 INSPECTION NO, INSPECTION RECORD Retain a copy with permit a PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: 6/..Jer 64 Type of Inspection: c&)/L&4 f - hc-- Address: t4®!o A 2 644/B Date Called: Special Instructions: ^ aT1 Date Wanted: a.m. Requester: .N € Phone No: C0 e9e 00437 pproved per applicable codes. Corrections required prior to approval. COMMENTS: (/ii1I—V., Afr Inspector: <a) ( ` )� l Date: / 29. zoo REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit t13 0350 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: 3Th t 4 Type of Inspection: 44-0t--z-q04 Address: 'fib BAga, A 0LON Date Called: Special Instructions: !V4i i Date Wanted:! 1.- 19 P.m. ett' -E5 Requester: Phone No: KMMApproved per applicable codes. Corrections required prior to approval. MENTS: Inspector: ea_) Date: ZD/7 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 b)31 ))s -o Project: 6-64,-./4 1. apex Type of Inspection: l/OPW90A deW4evt Address: 1 4K - !3 t 004 1 o Date Called: Special Instructions: Date Wanted: /13-9 a.en: Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. OMMENTS: 5 svmo ?►espl[.r.✓S Date: REINSPECTI N FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 outhcenter Blvd., Suite 100. Call to schedule reinspection. Inspector: INSPECTION NO. INSPECTION RECORD Retain a copy with permit JsI2?'ro PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: Adjedress: 401, EvelVat,8,-,14 %4o Date Called: Special Instructions: Date Wanted: /2 -Z7 a.m. - 'P.m. Requester: Phone Ni: Approved per applicable codes. COMMENTS: 611,0 en rrections raired prior to approval. Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 0 Project: 67 -Citi -01%. Type of Inspection: -17200L-Ikk. Address: lap 1541414 ilk eD P.74V Date Called: Special Instructions: lALsS Atrffc6 Date Wanted: i Z 'c( . IS p.m. Requester: Phone No: ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: l Orreee Inspector: Date:/2 ✓/'/� REINSP!CTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Gall to schedule reinspection. PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D18-0350 DATE: 11/05/18 PROJECT NAME: STERLING SOUTHCENTER- SALES OFFICE SITE ADDRESS: 406 BAKER BLVD SUITE 160 X Original Plan Submittal Revision # before Permit Issued Revision # after Permit Issued Response to Correction Letter # DEPARTMENTS: PFJ U lo\( Building Division mM NPS li \k`6 Public Works Al" kW C 1134-10 NL Fire Prevention Fire Prevention Structural Mc, M2 * Planning Division nPermit Coordinator NI PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 11/06/18 Structural Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: Approved Corrections Required n (corrections entered in Reviews) Approved with Conditions Denied ., p (ie: Zoning Issues) �j Notation: r/\ � - r(A (0 f l ` cor DUE DATE: 12/04/18 n REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire 0 Ping ❑ PW 0 Staff Initials: 12/18/2013 ALLIANCE PACIFIC NW BLDR,/,LC Washington State department of Labor & Industries C :Home Espanol Contact Safety & Health Claims & Insurance Page 1 of 3 Search L&I A -Z Index Workplace Rights ALLIANCE PACIFIC NW BLDRS LLC Owner or tradesperson HARRISON, BRETT ROBERT Principals HARRISON, BRETT ROBERT, PARTNER/MEMBER CT CORPORATION, AGENT WA UBI No. 603 221 710 2525 E. Camelback Road Suite 500 PHOENIX, AZ 85016 206-330-0618 Business type Limited Liability Company License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. ALLIAPN871 LK Effective — expiration 06/12/2013— 06/12/2019 Bond Cincinnati Ins Co Bond account no. 0548995 Received by L&I 06/12/2013 Active. Meets current requirements. $12,000.00 Effective date 07/12/2012 Expiration date Until Canceled Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=603221710&LIC=ALLIAPN871 LK&SAW= 12/10/2018 ALLIANCE PACIFIC NW BLDRS LLC Insurance r Gemini Ins Co Policy no. VGGP003077 $1,000,000.00 Received by L&I Effective date 01/31/2018 01/31/2018 Expiration date 01/31/2019 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts Page 2 of 3 No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp No active workers' comp accounts during the previous 6 year period. Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 02/08/2017 Inspection no. 317943117 Location 1001 James street Seattle, WA 98104 Inspection results date 01/29/2016 Inspection no. 317939075 Location No violations No violations Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=603221710&LIC=ALLIAPN871LK&SAW= 12/10/2018 ALLIANCE PACIFIC NW BLDLC 124 Denny Way Seattle, WA 98109 0 Page 3 of 3 © Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=603221710&LIC=ALLIAPN871LK&SAW= 12/10/2018 P MARVELLE MARKETING CENTER TENANT IMPROVEMENT PERMIT 11/2/2018 APPLICABLE CODES 2015 TUKWILA MUNICIPAL CODES (TMC) 2015 INTERNATIONAL BUILDING CODES (IBC) 2015 WASHINGTON STATE BUILDING CODE (SBCC) 2015 UNIFORM PLUMBING CODES (UPC) 2015 INTERNATIONAL MECHANICAL CODES (IMC) 2017 NATIONAL ELECTRICAL CODES (NEC) 2015 WASHINGTON STATE ENERGY CODES (WSEC) 2014 LIQUEFIED PETROLEUM GAS CODE (NFPA 58) 2015 NATIONAL FUEL GAS CODE (NFPA 54) (FOR LP GAS INSTALLATION ONLY) 2009 ICC/ANSI A117.1 (BARRIER FREE CODES) ZONING INFORMATION APPLICABLE CODE: 2015 TUKWILA MUNICIPAL CODES (TMC) PROJECT ZONE: TUC TUKWILA URBAN CENTER & TOD TRANSIT ORIENTED DEVELOPEMENT DRAWING INDEX 0 - ARCH DATA A0.01 A0.10 A0.11 4 - ARCHITECTURAL A1.01 A1.02 A6.01 A9.01 GENERAL NOTES AND LEGENDS GENERAL ACCESSIBILITY REQUIREMENTS GENERAL ACCESSIBILITY REQUIREMENTS FLOOR PLAN - DEMO PLAN FLOOR PLAN - LEVEL 1 WINDOW, DOOR TYPES & SCHEDULES DETAILS & WALL TYPES L_ ADDRESS 406 BAKER BOULEVARD, SUITE 160 TUKWILA, WA 98188 ASSESSOR'S PARCEL NUMBER 0223100037 LEGAL DESCRIPTION ANDOVER INDUSTRIAL PARK # 2 BEG ON S LN 250 FT E OF SW COR TH N 01-05-06 E 214 FT TH S 88-25-27 E 152.01 FT TH S 01-05-06 W 214 FT TO SD S LN TH W 152.01 FT TO BEG PROJECT DIRECTORY OWNER/DEVELOPER ALLIANCE RESIDENTIAL COMPANY 1325 4TH AVE., STE. 1005 SEATTLE, WA 98101 PHONE: 206.567.7230 CONTACT: EVAN LAWLER E-MAIL: elawler@allresco.com ARCHITECT URBAL ARCHITECTURE 1938 FAIRVIEW AVE E, SUITE 100 SEATTLE, WA 98102 PHONE: 206.676.5649 CONTACT: ALEX DALZELL E-MAIL: alexd@urbalarchitecture.com PROJECT DESCRIPTION & DATA DESCRIPTION A 2,498 GROSS SQUARE FLOOR TENANT IMPROVEMENT OF AN EXISTING RETAIL SUITE. TENANT IMPROVEMENT IS TO DEMOLISH INTERIOR SPACE DIVIDING WALLS WITHIN THE SUITE AND CONSTRUCT NEW PARTIAL HEIGHT PARTITIONS TO SIMULATE THE LAYOUT OF A RESIDENTIAL UNIT FOR MARKETING PURPOSES ONLY. NO ALTERATIONS ARE PROPOSED TO THE SITE, PARKING, REFUSE COLLECTION, PLANTINGS, STRUCTURE, FIRE/SPRINKLER SYSTEMS, EXITING SIGNAGE OR TO THE EXTERIOR OF THE BUILDING. ZONING: TUKWILA URBAN CENTER, TRANSIT ORIENTED DEVELOPMENT, TUC-TOD CONSTRUCTION TYPE: TYPE VA OCCUPANCY CLASSIFICATION: BUSINESS GROUP B (NO PROPOSED CHANGE) GROSS FLOOR AREA: 2498 SQ.FT. (NO PROPOSED CHANGE) OCCUPANCY LOAD FACTOR: 100 GROSS (PER TABLE 1004.1.2 IBC 2015 TOTAL OCCUPANT LOAD: 25 OCCUPANTS PROPERTY LINE 7'-0" 27'-3" ADDRESS: 406 BAKER BLVD a M ZONE: TUC-TOD PARCEL NO.: 0223100037 SEPARATE PERMIT RE_ gUIRED FOR: MechaniCal EY Electrical 12' Plumbing E3/Gara/Gas Piping City of Tukwila BUILDING DIVISION ADJACENT BUILDING Qc�� No changes shall be made to the scope of work wltnout prior approval of the - Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review. EXISTING 32 PARKING STALLS LEGEND AREA OF WORK NN\NNN% SITE A0.0, 1" = 20'-0" PLANNING APPROVED No changes can be madeto these plans without approval from the Planning Division of DCD Approved By: S BAKER BLVD FIL COPY Permit No. Plan review approval is subject to errors and omissions Approval of construction documents does not authorize the violation of any adopted code or ordinance Receipt of approved Fiera Copy and conditions nowledged Date:, "+ By:, Date: OCCUPANT LOAD CALCULATION BUSINESS OCCUPANCY GROUP 2498 SG.FT. GROSS OCCUPANT LOAD FACTOR = 100 GSF OCCUPANT LOAD = 25 OCCUPANT LOAD DOES NOT EXCEED 49. ONLY ONE EXIT REQUIRED PER IBC TABLE 1006.2.1 EXIT LOAD KEY EXIT LOAD (1/2 OF OCCUPANT LOAD IF 2 EXITS EXIT CAPACITY 0.3" PER OCCUPANT FOR STAIRS 0.2" PER OCCUPANT FOR ALL OTHER COMPONENTS TYP DOOR WIDTH: 36" THEREFRORE 36/0.2=180 EXIT CAPACITY REVIEWED FOR CODE COMPLIANCE APPROVED nn DEC 052010tA� T� [Alk City of Tukwila BUILDING DIVISION 6\ LEVEL 1 OCCUPANCY/EXITING A0.0, 1/8" = 1'-0" URBALO ARCHITECTURE URBANIRURAL 1938 Fairview Avenue East SUITE 100 Seattle, WA 98102 info@urbalarchitecture.com www.urbalarchitecture.com T 206-257-0972 license 9776 REGISTERED ARCHITECT CHAD A. ENTZ STATE OF WASHINGTO 11.02.2018 consultant logo project name MARVELLE SOUTHCENTER, SALES OFFICE 406 BAKER BOULEVARD, TUKWILA, WA 98188 submittals/revisions TENANT IMPROVEMENT APPLICATION 11.02.2018 drawing title TITLE SHEET drawing information DATE 11.02.2018 SCALE As indicated DRAWN AJD JOB # 18-034 copyright © 2017 Urbal Architecture, PLLC Urbal Architecture, PLLC reserves common law copyright and other property rights in this document. All drawn and written information incorporated herein, is an instrument of Urbal Architecture PLLC's professional practice and shall not to be used in whole or in part without the written authorization of Urbal Architecture, PLLC. A0000 RECEIVED CITY OF TUKWILA NUV 0 5 2018 PERMIT CENTER GENERAL ABBREVIATIONS: URBAL GENERAL ABBREVIATIONS FACE OF MASONRY F.O.S. AB ANCHOR BOLT ABV ABOVE ACCUS ACOUSTICAL ACT ACOUSTICAL CEILING OLE AD AREA DRAIN ADDL ADDITIONAL ADJ ADJUSTABLE AFF ABOVE FINISH FLOOR AG ALUMINUM &GLASS ALC ALUMINUM CLAD ALT ALTERNATE PLUM ALUMINUM ALV ALUMINUM CLAD VINYL ALW ALUMINUM CLAD WOOD AN ANODIZED APPROX - APPROXIMATE APT APARTMENT ARCH ARCHITECTURAL AS ALUMINUM STOREFRONT AVG AVERAGE AVN AWNING B.O. BOTTOM OF BA BATH BC BOTTOM OF CURB BD BOARD BLW BELOW BITUM BITUMINOUS BLDG BUILDING BLKG BLOCKING BLW BELOW BM BEAM BSMT BASEMENT sir BETWEEN BUR BUILT-UP ROOFING BYD BEYOND C CASEMENT C&G CURB AND GUTTER CAB CABINET CB CATCH BASIN CC CENTER TO CENTER CIP CAST IN PLACE CIRC CIRCULATION CL CENTERLINE CLG CEILING CLR CLEAR CLR FIN CLEAR FINISH CMU CONCRETE MASONRY UNIT CO CLEAN OUT COL COLUMN CONC CONCRETE CONT CONTINUOUS CORR CORRIDOR CPT CARPET CT CERAMIC TILE CTB CERAMIC OLE BASE CTR CENTER CW COLD WATER CWG CLEAR W RED GLASS CVG CLEAR VERTICAL GRAIN D DRYER DBL DOUBLE DE DELAYED EGRESS DEMO DEMOLITION 01-1 DOUBLE HUNG DIA DIAMETER DR DOOR(S) DS DOWNSPOUT DW DISHWASHER DWG DRAWING EA EACH EB EXPANSION BOLT EF EACH FACE EL ELEVATION ELEC ELECTRIC(AL) ELEV ELEVATOR EMER EMERGENCY ENCL ENCLOSURE EP ELECTRICAL PANEL EQ EQUAL EQUIP EQUIPMENT ESCAL ESCALATOR ESMT EASEMENT EXH EXHAUST EXST - EXISTING EXT EXTERIOR F FIXED FA FIRE ALARM FAF FACTORY APPLIED FINISH FAP -. FIRE ALARM CONTROL PANEL FAPB - FIRE ALARM PULL BOX FB FLAT BAR FBG FIBERGLASS FC FIBER CEMENT FD FLOOR DRAIN FDC FIRE DEPARTMENT CONNECTION FDN FOUNDATION FDR FRENCH DOORS FE ARE EXTINGUISHER FEC FIRE EXTINGUISHER CABINET FF FINISHED FLOOR FIN FINISH FL FLUSH FLR FLOOR F.O.C. FACE OF CONCRETE F.O.F. FACE OF FINISH F.O.M. FACE OF MASONRY F.O.S. FACE OF STUDS FPL FIREPLACE FR FRAMING FRP - FIBER REINFORCED PLASTIC . FRT FIRE RETARDANT FRTW FIRE RETARDANT TREATED WOOD FT FOOT(ORFEET) FTG FOOTING FURR FURRING FUT FUTURE GA GAUGE GALV GALVANIZED GAR GARAGE GB GRAB BAR GC GENERAL CONTRACTOR GFRC GLASS FIBER REINFORCED CONCRETE GL CLASS GLB CLULAMINATEDBEAM GLZ GLAZING GND GROUND GS GARAGE SECTIONAL DOOR GSF GROSS SQUARE FEET GWB GYPSUM WALL BOARD HB HOSE BIB HC HOLLOW CORE HCW HOLLOW CORE WOOD HD HEAD HDO HIGH DENSITY OVERLAY HDWD HARDWOOD HM HOLLOW METAL HORIZ HORIZONTAL HVAC HEATING VENTILATION AR CONDITIONING HW HOT WATER HYDR HYDRAULIC , IBC INTERNATIONAL BUILDING CODE ID INTERIOR DESIGN LIC IMPACT ISOLATION CLASS IN INCH(ES) INCL INCLUDING INS INSULATION INT INTERIOR JAN JANITOR KB KEY BOX/KNOXBOX KD KNOCK DOWN KIT - KITCHEN KO KNOCKOUT KW - KILOWATTS LAM LAMINATE LAV LAVATORY LB POUND LE LINEAR FEET LOC LOCATION LTG LIGHTING LOW -E LOW GLAZING LVR LOUVER MAINT MAINTENANCE MAS MASONRY MAIL MATERIAL MAX MAXIMUM MB MACHINE BOLT MED MEDICINE MDF MEDIUM DENSITY FIBERBOARD MDO MEDIUM DENSITY OVERLAY MECH MECHANICAL MED MEDIUM MEMB MEMBRANE MEZZ MEZZANINE MFR MANUFACTURER MGR MANAGER MH MANHOLE MIN MINIMUM MIRR MIRROR MISC - MISCELLANEOUS MK MARK MP METAL, PAINTED MTD MOUNTED MTL METAL MULL MULLION NIC NOT IN CONTRACT NOM NOMINAL NSF NET SQUARE FEET NTS NOT TO SCALE 0/ OVER OA OVERALL OC ON CENTER OD OVERFLOW ROOF DRAIN OFCI OWNER FURNISHED/ CONTRACTOR INSTALLED - OFF OFFICE OF01 OWNER FURNISHED /OWNER INSTALLED OPP OPPOSITE OVHD OVERHEAD OZ OUNCE PB PARTICLE BOARD PC PRECAST CONCRETE PCF POUNDS PER CUBIC FOOD PED PEDESTAL PERF PERFORATED PERP PERPENDICULAR PIC PICTURE(WINDOW) PIV POST INDICATORVALV PL PROPERTY LINE PLAM PLASTIC LAMINATE PLAS PLASTER PLYWD PLYWOOD POLY POLYETHYLENE PREFAB PREFABRICATED PREFIN PREFINISHED PRKG PARKING PROP PROPERTY PRV PRESSURE REDUCING VALVE PSF POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH PNT POINT PT PRESSURE TREATED PTO PAINTED PJC POLYVINYLCILORIDE PVMT PAVEMENT QTY QUANTITY R RISER RA RETURN AIR RAD RADIUS RC RESILIENT CHANNEL RCP REFLECTED CEILING PLAN RD - ROOF DRAIN REFR REFRIGERATOR. REINF REINFORCE REQD REQUIRE RESIL RESILIENT RL (INTERIOR) RELITE RSTRM RESTROOM RET RETAINING RO ROUGH OPENING ROW RIGHT OF WAY RW. RAIN WATER LEADER SA SUPPLY AIR SAF SAFETY LAMINATED SC SOLID CORE SCW SOLID CORE WOOD SECT SECTION SH SINGLE HUNG SHT SHEET SHTHG SHEATHING SIM SIMILAR SL SLIDING SLD SLIDING DOOR • SOG SLAB ON GRADE SP STANDPIPE SPG SPANDREL GLAZING SPEC SPECIFICATON SSTL STAINLESS STEEL ST STAINED STA STATION STAG STAGGERED STC SOUND TRANSMISSION CLASS STD STANDARD STL STEEL STM STEEL CHANNEL MEMBER STOR STORAGE STRUCT STRUCTURE (STRUCTURAL) SUSP SUSPENDED SV SHEET VINYL SYST SYSTEM T TEMPERED T&G TONGUE AND GROOVE T.O.B. TOP OF BEAM T.O.C. TOP OF CURB TD TRENCH DRAIN TEMP TEMPORARY T.O.F. TOP OF FOOTING T.O.F.F. TOP OF FINISH FLOOR THK THICKNESS) T.O.J. TOP OF JOIST T.O. TOP OF T.O.C. TOP OF CONCRETE T.O.P. TOP OF PARAPET T.O.W. TOP OF WALL TOPO TOPOGRAPHIC TP TOP OF PAVEMENT TR TREAD TRANS TRANSLUCENT GAZING TRTD TREATED TSTAT THERMOSTAT TV TELEVISION TYP TYPICAL UNEX • UNEXCAVATED UNFIN UNFINISHED UNO - UNLESS NOTED OTHERWISE UTL UTILITIY (OR UTILITIES) VB VINYL BASE VCT VINYL COMPOSITION TILE VEH VEHICLE VENT VENTILATION VERT VERTICAL VEST VESTIBULE VG VERTICAL GRAN V VINYL VIF VERIFYINFIELD VNF VINYL NAL -FLANGE VP VENEER PLASTER VTR VENT THROUGH ROOF W WASHING MACHINE WC WATER CLOSET WD WJOD W/D WASHER/DRYER WG WOOD &GLASS WCL WREGLASS WH WATER HEATER W/O WTHOUT. W.P. WORKING POINT WP WATER PROOF WRB WATR-RESISTIVE BARRIER WDW WINDOW(S) SYMBOLS LEGEND VIEW REFERENCES OBJECT REFERENCES T 206-257-0972 license BUILDING SECTION ROOM TAG SIM 1 DETAIL # ON SHEET ROOM NAME ROOM NAM submittals/revisions —" 101 ROOM # 150 SF� A10 ROOM (NET) SQUARE FOOTAGE SHEET # DETAIL CUT DOOR TAG DETAIL# ON SHEET SIM drawing title GENERAL NOTES AND LEGENDS DOOR It; REFER TO DOOR SCHEDULE Al 0 SHEET # ENLARGED PLAN OR DETAIL WINDOW TAG 1/SIM DETAIL # ON SHEET WINDOW #; REFER TO 4 WINDOW SCHEDULE , ''ABV A101 1 J SHEET # BUILDING ELEVATION 1 Ref MATERIAL TAG MATERIAL PER LEGEND PT -X MTRL moo. 4-- DETAIL #, TYP w rx 1 a A101 a 1 SHEET # 1 Ref PAINT COLOR PER LEGEND INTERIOR ELEVATION 1 Ref DETAIL #, WALL TAG WALL TYPE / *REFER TO SHEET A9.01 A FOR WALL ASSEMBLIES TYP 1 A101 > 1 SHEET # 1 Ref HIDDEN ELEVATION ROOF/FLOOR/CEILING TAG DETAIL # ON SHEET IM n.xx ROOF/ FLOOR/ CEILING TYPE A101 SHEET # REVISION TAG REVISION # GENERAL NOTES 1. THE DRAWINGS ARE INTENDED TO DESCRIBE THE OVERALL SCOPE OF WORK. IT IS THE INTENT OF THE CONTRACT DOCUMENTS THAT ALL WORK COMPLY WITH ALL APPLICABLE CODES AND REGULATIONS OF THE JURISDICTIONS HAVING AUTHORITY. NOTHING IN THE DRAWINGS SHALL BE CONSTRUED TO PERMIT AN INSTALLATION IN VIOLATION OF APPLICABLE CODES AND/OR RESTRICTIONS. SHOULD ANY CHANGE IN THE DRAWINGS BE NECESSARY IN ORDER TO COMPLY WITH THE APPLICABLE CODES AND/OR REQUIREMENTS, THE CONTRACTOR SHALL NOTIFY THE OWNERS REPRESENTATIVE AT ONCE AND CEASE WORK ON ALL PARTS OF THE CONTRACT WHICH ARE AFFECTED. THE WORK TO BE PERFORMED UNDER THIS CONTRACT SHALL BE IN FULL ACCORDANCE WITH THE LATEST RULES, REGULATIONS, RESTRICTIONS, REQUIREMENTS AND CODES. WORK PERFORMED IN VIOLATION OF SUCH SHALL BE CORRECTED AT NO EXPENSE TO'THE OWNER. 2. PRIOR TO COMMENCEMENT OF ANY PORTION OF THE WORK, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT OF DISCREPANCIES NOTED AMONG OR BETWEEN THE CONTRACT DOCUMENTS, OWNER - PROVIDED INFORMATION, SITE CONDITIONS, MANUFACTURER RECOMMENDATIONS, CODES OR REGULATIONS OF AUTHORITIES HAVING JURISDICTION. 3. PRIOR TO COMMENCEMENT OF ANY PORTION OF THE WORK, THE CONTRACTOR SHALL BECOME FAMILIAR WITH THE CONTRACT DOCUMENTS, OWNER -PROVIDED INFORMATION AND SITE CONDITIONS, INCLUDING TAKING FIELD MEASUREMENTS. 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF EXISTING UTILITIES. EXISTING UTILITIES SHOWN HAVE BEEN OBTAINED FROM AVAILABLE RECORDS AND ARE SHOWN FOR CONVENIENCE ONLY. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ADDITIONAL UTILITY LOCATIONS NOT SHOWN. 5. DIMENSIONS OF SITE CONDITIONS ARE FROM SURVEY BY OTHERS. ARCHITECT BEARS NO RESPONSIBILITY FOR ACCURACY OF THE SAME. DIMENSIONS ARE TO FACE OF EXTERIOR FRAMING, FACE OF CONCRETE, OR CENTER OF INTERIOR WALL STUD, UNLESS OTHERWISE NOTED. NOTIFY ARCHITECT OF ANY DISCREPANCIES FOUND. DO NOT SCALE DRAWINGS. 6. ALL DOORS LOCATED ADJACENT TO A PERPENDICULAR PARTITION AND NOT LOCATED BY DIMENSION ON PLANS, INTERIOR ELEVATIONS, OR DETAILS SHALL BE 5" FROM FACE OF STUD TO EDGE OF DOOR OPENINGS. 7. REPETITIVE ELEMENTS: TYPICAL WALL SECTIONS, FINISHES AND DETAILS ARE NOT INDICATED EVERYWHERE THEY OCCUR ON PLANS, ELEVATIONS AND SECTIONS. REFER TO DETAILED DRAWINGS. CONTRACTOR TO PROVIDE AS IF DRAWN IN FULL EVERYWHERE. 8. THE CONTRACTOR SHALL CONSULT THE PLANS OF ALL TRADES FOR OPENINGS THROUGH SLABS, WALLS, CEILINGS AND ROOFS FOR DUCTS, PIPES, CONDUIT, CABINETS AND EQUIPMENT, AND SHALL VERIFY THE SIZES AND LOCATIONS WITH SUBCONTRACTORS. 9. ABBREVIATIONS: THROUGHOUT THE PLANS ARE ABBREVIATIONS WHICH ARE IN COMMON USE. THE ARCHITECT WILL DEFINE THE INTENT OF ANY ABBREVIATION IN QUESTION. SEE SHEET A0.01 FOR GENERAL ABBREVIATIONS. ABBREVIATIONS OR PARTIAL CODE SECTIONS NOTED ON THIS PLAN AND PLAN REVIEW LIST ARE INTENDED TO INDICATE THE NATURE OF THE PLANS OR GIVE ADDITIONAL INFORMATION. THE FULL TEXT OF THE CODE ALWAYS APPLIES. 10. VERIFY ALL ROUGH -IN DIMENSIONS (HORIZONTAL AND VERTICAL) FOR ALL EQUIPMENT PROVIDED IN THE CONTRACT DOCUMENTS. VERIFY WITH THE OWNER'S REPRESENTATIVE THE SIZE, SHAPE AND UTILITY REQUIREMENTS OF EQUIPMENT PROVIDED BY OTHERS. 11. CONTRACTOR/ SUB -CONTRACTOR TO PROVIDE SOLID BACKING FOR ALL ATTACHED HARDWARE RODS, HANDRAILS AND GRAB BARS. l 8 REVIEWED FOR CODE COMPLIANCE APPROVED DEC 052018 City of Tukwila BUILDING DIVISION 0 3 50 L_ URBALr44 ARCHITECTURE URBANIRURAL 1938 Fairview Avenue East SUITE 100 Seattle, WA 98102 info@urbalarchitecture.com www.urbalarchitecture.com T 206-257-0972 license 9776 REGISTERED ARCHITECT n CHAD A. ENTZ STATE OF WASHINGTO 11.02.2018 consultant logo project name MARVELLE SOUTHCENTER, SALES OFFICE 406 BAKER BOULEVARD, TUKWILA, WA 98188 submittals/revisions TENANT IMPROVEMENT APPLICATION 11.02.2018 drawing title GENERAL NOTES AND LEGENDS drawing information DATE 11.02.2018 SCALE As indicated DRAWN Author JOB # 18-034 copyright © 2017 Urbal Architecture, PLLC Urbal Architecture, PLLC reserves common law copyright and other property rights in this document. All drawn and written information incorporated herein, is an instrument of Urbal Architecture PLLC's professional practice and shall not to be used in whole or in part without the written authorization of Urbal Architecture, PLLC. A0.01 RECEIVED CITY OF TUKWILA NOV 0 5 2018 PERMIT CENTER SIDE ELEVATION VIE1/11 48" - 60" A.F.F. 48" MIN A.F.F. 5/8" -2" LETTERING, SANS- SERIF, RAISED 1/32", TEXT PER PLANS EXIT ROUTE 1/10" I t 00 00 1/20" 00 00 00 semen TYP. BRAILLE (NTS1 /12 \ TACTILE EXIT SIGN A�5 3" = 1'-0" o M SEE IIC A117.1 703.3 FOR ADDITIONAL INFORMATION GRADE 2 BRAILLE DOMED OR ROUNDED DOTS, RAISED cco 0 0 ELECTRICAU DATA OUTLET OVER BASE CABINET ELECTRICAU DATA OUTLET 6 TYP. MOUNTING HEIGHTS 0 (44" WHEN OVER A BASE CAB SWITCHES, THERMOSTAT. EMERGENCY CALLS & OTHER CONTROLS 8" • BACKGROUND COLOR: BLUE NO. 15090 PER FEDERAL STANDARD 595B FIGURE COLOR: WHITE BORDER COLOR: WHITE SEE IBC 1110 FOR ADDITIONAL INFORMATION INT'L SYMBOL OF ACCESSIBILITY 3" = 1'-0" 42" MAX. 24" MIN. n TP DISPENSER SEAT COVER DISPENSER PAPER TOWEL DISPENSER/ TRASH RECEPTACLE 48" MAX TO OPENING ao 0 SEE 8/A0.10 FOR W.C. ELEVATIONS FLUSH CONTROLS ON WIDE SIDE OF W.C. WALL -MOUNTED SINK, INSULATE OR COVER LAVATORY TAILPIPE AND HOT WATER LINES CLEAR FLOOR SPACE, FORWARD APPROACH • T • • k • • •-�-, J • = E10� COMMON USE SINGLE BATHROOM ko.ic 1/2" = 1'-0" SOAP DISPENSER 44" MAX TO BUTTON TOWEL BAR 3 CO 0 BOTTOM EDGE LAVATORY/ VANITY MIRROR OTHER FIXTURES NOT ALLOWED IN THIS AREA TURNING CIRCLE WALL -MOUNTED LAVATORY 1-1/4" -2" DIAMETER RETURN ENDS TO WALL TYP. GRAB— BAR SECTION FLUSH CONTROLS URINAL A�•" 1/2" = 1'-0" INSULATE OR COVER LAVATORY TAILPIPE AND HOT WATER LINES TO T.O. SINK RIM 0) ti N KNEE & TOE SPACE 6" 17" -25" CLEAR FLOOR SPLACE, FORWARD APPROACH 17" -25" _t s -- r 1 CO PLAN VIEW COMMON USE LAVATORY \A0.10 1/2" = 1'-0" GRAB BAR FRONT ELEVATION VIEW 39" -41" 54" MIN. GRAB BAR 12" MAX 42" MIN. .To 0 M 8� COMMON USE ACCESSIBLE WC COMPARTMENT r 18" 32" MIN. CLR. J DOOR WIDTH 12" i REQ'D IF DOOR HAS LATCH AND CLOSER FRONT APPROACHES r X=36" MIN. IF Y=60" X=42" MIN. IF Y=54" 1 L I 32" MIN. CLR. 22" 48" IF DOOR HAS LATCH AND CLOSER J J DOOR WIDTH 1 12" 1jr r REQ D IF DOOR HAS / LATCH AND CLOSER HINGE APPROACHES DOOR CLR AT PUBLIC/COMMON AREAS 3/8" = 1'-0" 59" MIN CO J FLUSH CONTROLS ON WIDE SIDE OF W.C. 102" 34" MIN. PLAN VIEW A0.10 1/2" = 1'-0" L- 54" IF DOOR HAS A CLOSER a 24" L 48" IF DOOR HAS A CLOSER LATCH APPROACHES J • • •� TURNING SPACE 48" r i i CLEAR FLOOR SPACE 60" 12" 12" N CLEAR FLOOR SPACES r 3/8" = 1'-0" 1 32" MIN. CLR. L J DOOR WIDTH POCKET DOOR r L T -SHAPED TURNING SPACE NOTE: ACCESSIBLE DOOR SURFACE TO MAINTAIN A SMOOTH SURFACE ON THE PUSH SIDE EXTENDING THE FULL WIDTH OF THE DOOR AS PER ANSI AAA7 A AAA '111 N B- REVIEWIED FOR CODE COMPLIANCE . APPROVED DEC 05 2018 City of Tukwila BUILDING DIVISION 35d URBALe ARCHITECTURE URBANIRURAL 1938 Fairview Avenue East SUITE 100 Seattle, WA 98102 info@urbalarchitecture.com www.urbalarchitecture.com T 206-257-0972 license 9776 REGISTERED ARCHITECT \ CHAD A. ENTZ STATE OF WASHINGTO 11.02.2018 consultant logo project name MARVELLE SOUTH CENTER, SALES OFFICE 406 BAKER BOULEVARD, TUKWILA, WA 98188 submittals/revisions TENANT IMPROVEMENT APPLICATION 11.02.2018 drawing title GENERAL ACCESSIBILITY REQUIREMENTS drawing information DATE 11.02.2018 SCALE As indicated DRAWN AR JOB # / 18-034 copyright © 2017 Urbal Architecture, PLLC Urbal Architecture, PLLC reserves common law copyright and other property rights in this document. All drawn and written information incorporated herein, is an instrument of Urbal Architecture PLLC's professional practice and shall not to be used in whole or in part without the written authorization of Urbal Architecture, PLLC. A0.10 RECEIVED CITY OF TUKWILA NUV 0 5 2018 PERMIT CENTER L • 00 Al f MAX A X LIMITS OF PROTRUDING OBJECTS 1/2" = 1'-0" >10"-25" MAX SIDE REACH 6 OBSTRUCTED RACH TYP. \+ • 10" MAX 4. SIDE REACH CO \ \ FORWARD REACH FORWARD REACH A0.11 1/2" = 1'-0" 10" MAX 4. SIDE REACH FORWARD REACH UNOBSTRUCTED REACH, TYP. 1/2" = 1'-0" REVIEWED FOR CODE COMPLIANCE APPROVED DEC 0 5 2018 City of Tukwila BUILDING DIVISION 1 8- c:.3..;.5i URBALP ARCHITECTURE URBANIRURAL 1938 Fairview Avenue East SUITE 100 Seattle, WA 98102 info@urbalarchitecture.com www.urbalarchitecture.com T 206-257-0972 license 9776 REGISTERED ARCHITECT CHAD A. ENTZ STATE OF WASHINGTO 11.02.2018 consultant logo project name MARVELLE SOUTHCENTER, SALES OFFICE 406 BAKER BOULEVARD, TUKWILA, WA 98188 submittals/revisions TENANT IMPROVEMENT APPLICATION 11.02.2018 drawing title GENERAL ACCESSIBILITY REQUIREMENTS drawing information DATE 11.02.2018 SCALE 1/2" = 1'-0" DRAWN AR JOB # 18-034 copyright © 2017 Urbal Architecture, PLLC Urbal Architecture, PLLC reserves common law copyright and other property rights in this document. All drawn and written information incorporated herein, is an instrument of Urbal Architecture PLLC's professional practice and shall not to be used In whole or in part without the written authorization of Urbal Architecture, PLLC. A0.11 RECEIVED CITY OF TUKWILA NUV 0 5 2018 PERIL IT CENTER ADJACENT TENANT SPACE 2 ' ZZZZ7� CLEREST0RYAB0VE-, 79 14 14 1/1 • EXISTING COLUMN TO REMAIN 011-1=ZZZ��0 IA -==9 rs� zL rZ1Z172 IA 14 Id VI H id ri I I 01 1/1 IAIA O Id IA r,, r, id,i 0 vi 0 o U 11 � VI Id N I),0 ii/J r , rrlF7Z2Z �'Tl'�Z2ZZZ II II II (11I / \-11 II II ISI 1�1 1�1 1/ EXISTING FLOOR DRAIN TO IA BE CAPPED AND FLUSH WITH 14 FLOOR 1 DEMOLITION PLAN - LEVEL 1 I A� 1/4" = 1'-0" L_ DEMOLITION PLAN LEGEND 6= INDICATES EXISTING WALL TO BE DEMOLISHED INDICATES EXISTING WALL TO REMAIN REVIEWED FOR CODE COMPLIANCE APPROVED DEC 0 5 2018 City of Tukwila BUILDING DIVISION l:9- O35O Li L ARCHITECTURE URBANIRURAL 1938 Fairview Avenue East SUITE 100 Seattle, WA 98102 info@urbalarchitecture.com www.urbalarchitecture.com T 206-257-0972 license 9776 REGISTERED ARCHITECT CHAD A. ENTZ STATE OF WASHINGTO 11.02.2018 consultant logo project name MARVELLE SOUTHCENTER, SALES OFFICE 406 BAKER BOULEVARD, TUKWILA, WA 98188 submittals/revisions TENANT IMPROVEMENT APPLICATION 11.022018 drawing title FLOOR PLAN - DEMO PLAN drawing information DATE 11.02.2018 SCALE As indicated DRAWN AJD JOB # 18-034 copyright © 2017 Urbal Architecture, PLLC Urbal Architecture, PLLC reserves common law copyright and other property rights in this document. All drawn and written information incorporated herein, is an instrument of Urbal Architecture PLLC's professional practice and shall not to be used in whole or in part without the written authorization of Urbal Architecture, PLLC. A100 1 RECEIVED CITY OF TUKWILA NUV 0 5 2018 PERMIT CENTER P L_ 10'-6 10'-6" 12-0" 8'-65/8" 8'-13/4"' 9'-0" 6' - 8" 10'-73/4" ADJACENT TENANT USE: TOBACCO SUPPLY STORE EXISTING STORAGE CLOSET 59 SF' EXISTING W.C. 53 SF W.C. 53 SF EXISTING KITCHENETTE OFFICE 140 SF OFFICE 135 SF 8'-8" AFF TYP.4, MEETING RM 169 SF ALL UNIT MOCKUP A, PLUMBING FIXTURES ARE co TO BE NON-FUNCTIONING, CC AESTHETIC ONLY 8' 8° AFF TYP. EXISTING ACT CEILING @ 14'-0" ABOVE FINISH FLOOR 10'911/16" 2'-115/8" 3'-21/2" NEW OPEN FRAME SUSPENDED CEILING 13'-27/16" 3' - 2 13/16" 4' - 1 5/8" M CV FEVIEWED FOR CODE COMPLIANCE APPROVED PLAN NOTES: 1. ALL NEW WALLS ARE NOT FULL HEIGHT. FOR ALL PROPOSED WALLS, 7 ENCLOSURES THAT ARE PERMITTED TO BE PENETRATED BY DUCTS 11, INTERIOR DOORS SHALL BE 4" MIN FROM ADJACENT WALLS UNLESS AND AIR TRANSFER OPENINGS SHALL BE PROTECTED WITH APPROVED NOTED OTHERWISE. FIRE AND SMOKE DAMPERS TOP OF WALL ELEVATION IS TO BE 8'-8" SEE SHEET A9.01 FOR WALL TYPE DETAILS. 8 SHAFT ENCLOSURES THAT ARE PERMITTED TO BE PENETRATED BY SEE SHEETS A6.01 FOR DOOR AND WINDOW SCHEDULES. DUCTS AND AIR TRANSFER OPENINGS SHALL BE PROTECTED WITH APPROVED FIRE AND SMOKE DAMPERS SEE SHEETS A0.10 - A0.11 FOR GENERAL ACCESSIBILITY REQUIREMENTS. 9. DUCT PENETRATIONS IN FIRE PARTITIONS SHALL BE PROTECTED WITH APPROVED FIRE DAMPERS. SEE SHEET A0.00 FOR OCCUPANCY AND EXITING DIAGRAMS. 10. LISTED SMOKE DAMPER SHALL BE PROVIDED AT EACH POINT A DUCT OCCUPANT LOAD OF ASSEMBLY OCCUPANCIES OR SPACES SHALL BE OR AIR TRANSFER OPENING PENETRATES A CORRIDOR ENCLOSURE POSTED IN A CONSPICUOUS PLACE, NEAR THE MAIN EXIT FROM SPACE. REQUIRED TO HAVE SMOKE AND DRAFT CONTROL DOORS. VIALUHATCH LEGEND: FRAMED WALL EXISTING WALL SIGNAGE LEGEND: DEC 052018 City of Tukwila BUILDING DIVISION �Exl EXIT SIGN W/ EMERGENCY LIGHTING EMERGENCY LIGHTING FIRE EXTINGUISHER CABINET IFECI b18-00 Q350 URBAL ARCHITECTURE URBANIRURAL 1938 Fairview Avenue East SUITE 100 Seattle, WA 98102 info@urbalarchitecture.com www.urbalarchitecture.com T 206-257-0972 license 9776 REGISTERED ��,, ARCHITECT CHAD A. ENTZ STATE OF WASHINGTO 11.02.2018 consultant logo project name MARVELLE SOUTHCENTER, SALES OFFICE 406 BAKER BOULEVARD, TUKWILA, WA 98188 submittals/revisions TENANT IMPROVEMENT APPLICATION 11.02.2018 drawing title FLOOR PLAN - LEVEL 1 drawing information DATE 11.02.2018 SCALE As indicated DRAWN AJD JOB # 18-034 copyright © 2017 Urbal Architecture, PLLC Urbal Architecture, PLLC reserves common law copyright and other property rights in this document. All drawn and written information incorporated herein, is an instrument of Urbal Architecture PLLC's professional practice and shall not to be used in whole or in part without the written authorization of Urbal Architecture, PLLC. A1.02 nECEIVED CITY OF TUKWILA NOV 0 5 2010 PERMIT CENTER P DOOR SCHEDULE (NON RES) DOOR LOCATION TYPE LEAF SIZE CONSTRUCTION FRAME FINISH GLAZING FIRE RATING U -VALUE AREA (SF) NOTES LEVEL 1 101 OFFICE C 3'-0" x 7'-0" AG AL FAF CL FINISH FRAME COLOR PANEL COLOR L4, P4, P5 102 OFFICE C 3'-0" x 7'-0" AG AL FAF CL HM AS P L4, P4, P5 103 MEETING RM C 3'-0" x 7'-0" AG AL FAF CL HCW WD P4, P5 DOOR SCHEDULE (RES MOCK-UP) DOOR LOCATION TYPE LEAF SIZE CONSTRUCTION FRAME GLAZING FINISH FRAME COLOR PANEL COLOR FIRE RATING U -VALUE NOTES 1- SWING R1 UNIT ENTRY H 3'-0" x T-0" SCW HM AS P PER ID PER ID P4, P5 R2 BATHROOM A 3'-0" x 6'-8" HCW WD P PER ID PER ID drawing information P4, P5 R4 BEDROOM A 3'-0" x 6'-8" HCW WD / P PER ID PER ID copyright © 2017 Urbal Architecture, PLLC Urbal Architecture, PLLC reserves common law copyright and other property rights in this document. All drawn and written information incorporated herein, is an instrument of Urbal Architecture PLLC's professional practice and shall not to be used in whole or in part without the written authorization of Urbal Architecture, PLLC. \. P4, P5 R5 BEDRM. CLOSET A 3'-0" x 6'-8" HCW WD P PER ID PER ID P4, P5 R7 UTILITY ROOM M 3'-O" x 6'-8" HCW WD P PER ID PER ID P4, P5 WINDOW SCHEDULE - RELITES MARK STYLE FRAME GLASS FINISH U -VALUE SHGC AREA (SF) NOTES COMMENTS R1 AS AL T FAF, BLACK WHITE 0.26 44 SF 39 SF DESIGN PER ID R1 AS AL T FAF, BLACK FAF WHITE 44 SF 0.22 DESIGN PER ID R2 AS AL T FAF, BLACK 44 SF DESIGN PER ID WINDOW SCHEDULE (VNL)1 MARK STYLE FRAME GLAZING FINISH COLOR U -VALUE SHGC AREA NOTES COMMENTS A2 C VNF INS FAF WHITE 0.26 0.18 39 SF 9776 REGISTERED ARCHITECT El SL VNF INS, T FAF WHITE 0.29 0.22 64 SF L ABBREVIATIONS A AWNING AL ALUMINUM AS ALUMINUM STOREFRONT C CASEMENT CL CLEAR FINISH DH DOUBLE HUNG F FIXED FAF FACTORY APPLIED FINISH FBG FIBERGLASS INS INSULATED - LOW E P PICTURE PTD PAINTED RL INTERIOR RELITE SAF SAFETY LAMINATE SH SINGLE HUNG SL SLIDING T TEMPERED TRANS TRANSLUCENT GLAZING VNF VINYL NAIL -FLANGE WC WOOD -CLAD W WOOD DOOR HARDWARE NOTES: LI DEADBOLT L2 AUTOMATIC FLUSH BOLTS L3 MANUAL FLUSH BOLTS L4 PRIVACY LOCK L5 SELF-LOCKING L6 ELECTRIC LOCK L9 PANIC HARDWARE L10 PASSAGE HARDWARE LI1 PUSH PLATE/PULLS, NO LATCH L12 AUTO CLOSURE, TIED TO SMOKE ALARM Cl CLOSER C2 SPRING HINGE C3 MAGNETIC DOOR HOLDER ACTIVATED BY SMOKE ALARM C4 MOTION SENSOR AUTOMATIC DOOR OPENER; DOORS SHALL BE MANUALLY OPERABLE DURING POWER FAILURE C5 ACCESSIBLE POWER OPERATOR P1 THRESHOLD P2 FULL WEATHER STRIP P3 DOOR SWEEP P4 KICK PLATE P5 DOOR STOP Al SMOKE GASKET A2 SILENCER A5 INTERCOM A6 VIEWPORT (PROVIDE TWO AT TYPE A UNITS) A7 DOOR CHIME A8 FULL PERIMETER SOUND SEAL M1 BYPASS HARDWARE M2 BARN DOOR HARDWARE NOTE: ALL PANES ON WINDOWS El AND A2 TO HAVE A TRANSLUCENT FILM APPLIED TO THE NON -UNIT SIDE OF THE WINDOW • FINISH FLOOR 6'-0" 3'-0" 3'-0" 0 FIXED W/ CASEMENT 1/4"=1'-0" 1 1" FINISH FLOOR 2 ARCHITECTURE URBANIRURAL 1938 Fairview Avenue East SUITE 100 Seattle, WA 98102 `, SG SG license ,' FINISH FLOOR LEVEL 1 28' - 0" RELITE WINDOW 1/4" = 1'-0" GLASS PANEL FINISH FLOOR 2 ARCHITECTURE URBANIRURAL 1938 Fairview Avenue East SUITE 100 Seattle, WA 98102 `, T 206-257-0972 license ,' 9776 REGISTERED ARCHITECT CHAD A. ENTZ STATE OF WASHINGTO 11.02.2018 / project name MARVELLE SOUTHCENTER, SALES OFFICE 406 BAKER BOULEVARD, TUKWILA, WA 98188 / submittals/revisions / SG SG / / / drawing title WINDOW, DOOR TYPES & SCHEDULES drawing information / SCALE As indicated DRAWN AJD / copyright © 2017 Urbal Architecture, PLLC Urbal Architecture, PLLC reserves common law copyright and other property rights in this document. All drawn and written information incorporated herein, is an instrument of Urbal Architecture PLLC's professional practice and shall not to be used in whole or in part without the written authorization of Urbal Architecture, PLLC. \. A6001 RECEIVED CITY OF TUKWILA NUV 0 5 2018 PERMIT CENTER 8G \, • SG LEVEL 1 28' - 0" RELITE WINDOW 1/4" = 1'-0" GLASS PANEL FINISH FLOOR LEVEL 1 28'-0" 41 RELITE WINDOW 1/4" = 1'-0" FLUSH 1/4"=1'-0" FINISH FLOOR METAL LOUVER, SIZED PER MECHANICAL; PAINT TO MATCH DOOR FINISH FLOOR SWING W/ LOUVER 1/4"=1'-0" REVIEWED FOR CODE COMPLIANCE APPROVED DEC 0 5 2018 City of Tukwila BUILDING DIVISION X18- 0350 2 ARCHITECTURE URBANIRURAL 1938 Fairview Avenue East SUITE 100 Seattle, WA 98102 `, T 206-257-0972 license / 9776 REGISTERED ARCHITECT CHAD A. ENTZ STATE OF WASHINGTO 11.02.2018 / project name MARVELLE SOUTHCENTER, SALES OFFICE 406 BAKER BOULEVARD, TUKWILA, WA 98188 / submittals/revisions TENANT IMPROVEMENT APPLICATION 11.02.2018 SG SG LEVEL 1 28'-0" 41 RELITE WINDOW 1/4" = 1'-0" FLUSH 1/4"=1'-0" FINISH FLOOR METAL LOUVER, SIZED PER MECHANICAL; PAINT TO MATCH DOOR FINISH FLOOR SWING W/ LOUVER 1/4"=1'-0" REVIEWED FOR CODE COMPLIANCE APPROVED DEC 0 5 2018 City of Tukwila BUILDING DIVISION X18- 0350 2 ARCHITECTURE URBANIRURAL 1938 Fairview Avenue East SUITE 100 Seattle, WA 98102 info@urbalarchitecture.com www.urbalarchitecture.com T 206-257-0972 license 9776 REGISTERED ARCHITECT CHAD A. ENTZ STATE OF WASHINGTO 11.02.2018 consultant logo project name MARVELLE SOUTHCENTER, SALES OFFICE 406 BAKER BOULEVARD, TUKWILA, WA 98188 submittals/revisions TENANT IMPROVEMENT APPLICATION 11.02.2018 drawing title WINDOW, DOOR TYPES & SCHEDULES drawing information DATE 11.02.2018 SCALE As indicated DRAWN AJD JOB # 18-034 copyright © 2017 Urbal Architecture, PLLC Urbal Architecture, PLLC reserves common law copyright and other property rights in this document. All drawn and written information incorporated herein, is an instrument of Urbal Architecture PLLC's professional practice and shall not to be used in whole or in part without the written authorization of Urbal Architecture, PLLC. \. A6001 RECEIVED CITY OF TUKWILA NUV 0 5 2018 PERMIT CENTER r L_ WALL ASSEMBLIES ASSEMBLY TYPE DETAIL info@urbalarchitecture.com www.urbalarchitecture.com T 206-257-0972 license 9776 REGISTERED ARCHITECT DESCRIPTION FIRE RATING SOUND RATING INTERIOR WALLS - WOOD FRAMED TENANT IMPROVEMENT APPLICATION 11.02.2018 A l �''i•• TYP. INTERIOR PARTITION drawing title DETAILS & WALL TYPES drawing information DATE 11.02.2018 SCALE 1 1/2" = 1'-0" DRAWN Author • • 1/2" GWB 2X4 WOOD STUDS 1/2" GWB copyright © 2017 Urbal Architecture, PLLC Urbal Architecture, PLLC reserves common law copyright and other property rights in this document. All drawn and written information Incorporated herein, is an instrument of Urbal Architecture PLLC's professional practice and shall not to be used in whole or in part without the written authorization of Urbal Architecture, PLLC. NOT RATED T T A3• INTERIOR PARTITION • • 1/2" GWB 2X6 WOOD STUDS 1/2" GWB NOT RATED ` B 4 v VTAC ENCLOSURE (NON LOAD BEARING) • • • • • 5/8" TYPE X GWB 1 5/8" STEEL STUDS @ 24" O.C. R-8 BATT INSULATION 5/8"TYPEXGWB NOT RATED NOT RATED .._ , ..:. :. ,...... .. .:. , : " 1--�'......-... . ... . ...... ..... • 4T TOP OF WALL FINISH PER ID WALL TYPE PER PLANS A9.01 1 1/2" = 1'-0" TC 9 ` . 4 WALL TYPE PER PLANS ANCHOR BOTTOM PLATES TO SLAB EXISTING CONCRETE SLAB ON GRADE NON BEARING WALL @ CONCRETE SLAB 1 1/2" = 1'-0" 1'-3" 3T TOP OF UNIT WALL OVERHANG OPEN FRAME SUSPENDED CEILING PER SEISMIC AND MANUFACTURERS REQUIREMENTS. PAINTED PER ID 8'-2" AFF FINISH PER ID WALL TYPE PER PLANS A9.01 1 1/2" 1'-0" REVIEWED FOR CODE COMPLIANCE APPROVED DEC 0 5 2018 City of Tukwila BUILDING DIVISION bi963s0 URBALO ARCHITECTURE URBANIRURAL 1938 Fairview Avenue East SUITE 100 Seattle, WA 98102 info@urbalarchitecture.com www.urbalarchitecture.com T 206-257-0972 license 9776 REGISTERED ARCHITECT CHAD A. ENTZ STATE OF WASHINGTO 11.02.2018 consultant logo project name MARVELLE SOUTHCENTER, SALES OFFICE 406 BAKER BOULEVARD, TUKWILA, WA 98188 submittals/revisions TENANT IMPROVEMENT APPLICATION 11.02.2018 drawing title DETAILS & WALL TYPES drawing information DATE 11.02.2018 SCALE 1 1/2" = 1'-0" DRAWN Author JOB # 18-034 copyright © 2017 Urbal Architecture, PLLC Urbal Architecture, PLLC reserves common law copyright and other property rights in this document. All drawn and written information Incorporated herein, is an instrument of Urbal Architecture PLLC's professional practice and shall not to be used in whole or in part without the written authorization of Urbal Architecture, PLLC. A9 El 0 1 lECr ElvE CITY OF TUKWILA NOV 0 5 2018 PERMIT CENTER