PP - 515 INDUSTRY DR - ELEMENT HOTEL - PERMITS AND PLANS
515 INDUSTRY DR ASSOCIATED PERMITS 19-F-135 19-S-229 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Permit No.: Date: Reviewer: Element Hotel by Westin 515 Industry Drive 19-S-229 December 2, 2019 Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe. Section 18.5.5. • Minimum clearance around pipes: 2 " for 1 "-3.5", 4" for 4" and larger, see 4 exceptions. Section 18.4 • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line. Section 18.5.6. • Provide lateral and longitudinal bracing for changes in pipe direction per section 18.5.7. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement. Section 18.6. • Restraints for branch lines shall be at intervals per table 18.6.4 (a)(b) and section 18.6 and restrain sprig ups greater than 4'. Section 18.6.6. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Elevator hoistways shall comply with NFPA 13 Section 9.3.6. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • All interior control valves shall be readily accessible, labeled and located not more than 6 ft. above the floor. • Provide sprinkler protection beneath all stairs per NFPA 13, 9.3.4. • Each floor of a multi -story building shall have sectional control valves and waterflow switches. • In lieu of the required hose cabinets and hose, a Tukwila High -Rise Kit shall be installed in the fire control room. • Install Knox locking caps on all dry standpipe hose connections and FDC's. • The FDC's shall be within 50 ft. of a fire hydrant and shall be accessible for fire department use. • The drain(s) shall be plumbed to sanitary sewer. • Maintain a 4ft. clearance around the sprinkler riser for emergency access. • When the sprinkler riser is located inside a room, the door to the room shall have a sign with one -inch letters which reads "SPRINKLER RISER". • Provide a spare sprinkler head and wrench box at the riser. • An electrically supervised post indicating or wall indicating (PIV,WIV) is required, the height shall be 36 inches above grade. • FDC's and PIV's shall have the building number served by the FDC/PIV stenciled vertically in 3 -inch high white numbers on a "safety red" background, facing the direction of vehicular access. • The height of the fire department connection (FDC) shall be 36 to 48 inches above grade. • When subject to vehicular damage, protective guard posts or curbs are required around sprinkler valves and hydrants. Posts and curbs are to be painted yellow. • All exterior components of sprinkler systems to be painted red. • All control, drain, and test connection valves shall be provided with permanently marked weather-proof metal or rigid plastic identification signs. • FDC's shall be appropriately labeled per NFPA 13 and NFPA 14. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more sprinkler heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. • A flow test will be required at the most remote standpipe hose connection on the roof to confirm the minimum flow of 500 gpm at 100 psi required by NFPA 14 Section 7.10.0 for class 1 automatic wet standpipes. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2019 Edition. FIRE DEPARTMENT FIRE ALARM PLAN REVIEW COMMENTS Project Name: Permit No.: Date: Reviewer: Element Hotel 515 Industry Drive 19-F-135 July 10, 2019 Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Install a breaker handle clamp on fire alarm control panel and power supplies dedicated circuit breakers. • Manual pull stations shall be installed at ALL exterior exits and at ALL stair entrances on ALL floor levels. • Guest room smoke detectors shall annunciate by room number at a panel at the front desk in a constantly attended location and not report to central station. • All fire alarm functions and controls shall be available at the main panel (FACP-1) in the fire control room. • Install an exterior weather-proof bell/strobe facing the direction of fire department access. • Place "You Are Here" labels on smoke control panel building outline graphics. • The voice evacuation announcement shall be intelligible in all areas. • The minimum sound level in the bedrooms to be 75 decibels at the pillow and shall be low frequency. • Carbon monoxide detection shall be installed as required per International Building Code section 915.1.1 as amended by Washington State. • The location of the branch disconnecting means shall be permanently identified at the control unit. • System circuit disconnecting means shall be permanently identified as to its purpose with the marking "FIRE ALARM" in red. • All fire alarm control panels shall be fully addressable and report individual address points at central station. • A smoke detector shall be located above all fire alarm control equipment . • Fire Department Knox key boxes shall be provided for access to all fire alarm control panels. • U.L. central station supervision is required for all fire alarm systems. • Remote indicator lights are required on all above ceiling smoke/heat detectors. • Remote alarm annunciator is required at the main entrance if the fire alarm control panel is not visible from the main entrance. • When the fire alarm control panel is located inside a room, the door to the room shall have a sign with one -inch letters which reads "Fire Alarm" or "Fire Alarm Control". • The Fire Command Center door shall be labeled with minimum one -inch letters on contrasting background red on white or white on red. • The height of the display on fire alarm control panel/annunciator shall be between 60 to 70 inches above finished floor. • Duct detectors shall send a supervisory signal only upon activation. • All fire alarm work requires an electrical permit from the City of Tukwila Building Dept. • Fire alarm system shall comply with Tukwila City Ordinance #'s 2437 and 2330. • Final approval pending approval and commissioning of smoke control permit/system. M -F- IS c Reliance Electric 4795 Oakland Street, Denver, CO 80239 (720) 749-2850 element BY WESTIN 515 Industry Drive Tukwila, WA 98188 Kidde Vigilant Voltage Drop / Battery Calculations Project: Tukwila Element Panel Type: VM -1S Panel Name: FACP1 Circuit: NAC1 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms / 1000' 0 14 3.07 0 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 Totals: 0 0 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: • 0 Point to Point Method 0 Distance: End Line Voltage: Voltage Drop:: 0.00 of 20.40 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 Distance: 0 Voltage Drop: End of Line Voltage: 20.40 0.00 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 End of Line Method 0 Distance: Voltage Drop: End of Line Voltage: 20.40 0.00 Project: Tukwila Element Panel Type: VM -1S Panel Name: FACP1 Circuit: NAC2 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 0 14 3.07 0 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop END Z 0.000 0 I 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0,000 0 20.400 0.000 0.0000 T+I40:Q42otals: 0 0 CIRCUIT IS WITHIN LIMITS Percent Point to Point Method Current: 0 Drop: 0.00% 0 20.40 Distance: Voltage Drop: End of Line Voltage: 0.00 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Load Centering Method Current: 0 0 20.40 Distance: Voltage Drop: End of Line Voltage: 0.00 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% End of Line Method Current: 0 0 20.40 Distance: Voltage Drop: End of Line Voltage: 0.00 Project: Tukwila Element Panel Type: VM -1S Panel Name: FACP1 Circuit: NAC3 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guaae Ohms/ 1000' 0 14 3.07 0 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 Totals: 0 0 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 Point to Point Method Distance: 0 Voltage Drop: End of Line Voltage: 20.40 0.00 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 Load Centering Method Distance: 0 Voltage Drop: End of Line Voltage: 20.40 0.00 CIRCUIT 1S WITHIN LIMITS Percent Drop: 0.00% Current: 0 End of Line Method Distance: End Line Voltage: 0 20.40 Voltage Drop: 0.00 of Protect: Tukwila Element Panel Type: VM -1S Panel Name: FACP1 Circuit: NAC4 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guage Ohms/ 1000' 3.07 3.07 0 14 0 14 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 Totals: 0 0 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: Distance: 0 0 Voltage Drop: End of Line Voltage: 20.40 0.00 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 0 20.40 Distance: Voltage Drop: End of Line Voltage: 0.00 End of Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 0 Distance: Voltage Drop: End of Line Voltage: 20.40 0.00 Project: Tukwila Element Panel Type: vM-1 S Panel Name: FACP1 Battery Calculations Standy Alarm Circuit / Device Current Current Qty Total Standy Current Total Alarm Current Base Panel 381 481 VM -SLC" 120 132 VM-ETH1 42 54 VM-MFK 37 39 VM-NOC 98 98 VM -PMI 23 29 NAC Power NAC1 0 0 NAC2 0 0 NAC3 0 0 NAC4 0 0 1 3 1 1 1 1 0 0 0 0 1 1 1 1 381 360 42 37 98 23 0 0 0 0 0 0 0 0 481 396 54 39 98 29 0 0 0 0 0 0 0 0 TOTALS: 941 1097 Total Standby Current (Amps): 0.941 X 24 Hours 22.58 Amphours in Standby Total Alarm Current (Amps): 1.097 X 15 Mins: 0.27 Amphours in Alarm 22.86 Required Amphours +200/0 Safety Required Amphours: 22.86 Margin 27.43 Total Am hours p (2) 12V 28Ah Batteries Required. * VM -SLC is calculated at 100% capacity. (125 detectors & 125 modules per loop) DEVICE LEGEND Devices Current (Milliamps) Designator Part Number Description Light Ouput 0 15cd 30cd 75cd 95cd 110cd 177cd A B C D E F G H I J K L M N 0 P Q R S T U V W X Y SB4U SB4U-LF GSA-SBT SIGA-AB4G-LF INT-7ATW INT-8ATW EG1F-HD EG1F-VM EG1F-HDVM EGCF-VM EGCF-VMH EGCF-HDVM EGCF-HDVMH G4LFWF-H G4LFWF-HVM G4HFWF-S7VMC GCHFWF-S7VMC INT-4ASW XXXX DHF-24120C C01224T XXXX XXXX XXXX XXXX Sounder Base for V Series Detectors 520Hz Sounder Base for V Series Detectors Sounder Base for PCOS Detectors 520Hz Sounder Base for PCOS Detectors WP Wall Mount Horn/Strobe WP Wall Mount Horn/Strobe Wall Mount Horn Wall Mount Strobe Wall Mount Horn/Strobe Ceiling Mount Strobe Ceiling Mount High Candela Strobe Ceiling Mount Horn/Strobe Ceiling Mount High Candela Horn/Strobe Wall Mount 520Hz Horn Wall Mount 520Hz Horn/Strobe Wall Mount Speaker/Strobe Ceiling Mount Speaker/Strobe Weatherproof Speaker/Strobe XXXX Magnetic Door Hold-Open Carbon Monoxide Detector XXXX XXXX XXXX XXXX 28 92 52 92 180 90 22 85 127 245 _ 246 285 309 102 135 160 94 140 273 325 333 .551 111 152 281 333 324 554 166 219 266 381 437 78 101 188 245 94 140 273 325 551 159 15 75 Z N/A END OF CIRCUIT Protect: Tukwila Element Panel Type: vM-1S Panel Name: FACP2 Circuit: NAC1 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 0 14 3.07 0 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 Totals: 0 0 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop:0.00% Current:. 0 Distance: 0 End Line Voltage: 20.40 Voltage Drop: 0.00 of CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: I 0 Load Centering Method Distance:___0 20.40 End of Line Voltage: Voltage Drop: 0.00 End of Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: End Line Voltage: 0.00% Current:' 0 Distance: 0 20.40 Volta 9 a Dro 0.00 p:, of Project: Tukwila Element Panel Type: vM-IS Panel Name: FACP2 Circuit: NAC2 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms / 1000' 0 14 3.07 0 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 T+I40:Q42otals: 0 0 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Point to Point Method Current: 0 0 20.40 Distance: Voltage Drop: End of Line Voltage: 0.00 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Load Centering Method Current: 0 0 20.40 Distance: Voltage Drop: End of Line Voltage: 0.00 CIRCUIT IS WITHIN LIMITS Percent End Line Method Current: 0 Drop: 0.00% of Distance: 0 Voltage Drop: End of Line Voltage: 20.40 0.00 Project: Tukwila Element Panel Type: vM-IS Panel Name: FACP2 Circuit: NAC3 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Cuaae Ohms/ 1000' 0 14 3.07 0 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 Totals: 0 0 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent 0.00% Current: Drop: 0 Distance: 0 End Line Voltage: Voltage Drop: of 0.00 20.40 CIRCUIT IS WITHIN LIMITS 0.00% Current: Percent Drop: 0 Load Centering Method 0 End Line Voltage: 20.40 Distance: Voltage Drop: of 0.00 End of Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 0 End Line Distance: Voltage Drop: of Voltage: 0.00 20.40 Project: Tukwila Element Panel Type: vM-1S Panel Name: FACP2 Circuit: NAC4 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guage 0 14 0 14 Ohms/ 1000' 3.07 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 Totals: 0 0 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 Point to Point Method 0 20.40 Distance: End of Line Voltage: 0.00 Voltage Drop: CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 Load Centering Method 0 20.40 Distance: End of Line Voltage: 0.00 Voltage Drop: CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 End of Line Method 0 20.40 Distance: Voltage Drop: End of Line Voltage: 0.00 Protect: Tukwila Element Panel Type: vM-1S Panel Name: FACP2 Battery Calculations Standy Circuit / Device Current Alarm Current Qty Total Standy Current Total Alarm Current Base Panel 381 481 1 381 481 VM -SLC* 120 132 2 240 264 VM-NOC 98 98 1 98 98 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 NAC Power NAC1 0 0 1 0 0 NAC2 0 0 1 0 0 NAC3 0 0 1 0 0 NAC4 0 0 1 0 0 TOTALS: 719 843 otal Standby Current (Amps): 0.719 X 24 Hours 17.26 Amphours in Standby Total Alarm Current (Amps): 0.843 X 15 Mins: 0.21 Amphours in Alarm 17.47 Required Amphours Required Amphours: +20% Safety 17.47 96 Margin 20. Total Am hours p (2) 12V 26Ah Batteries Required. * VM -SLC is calculated at 100% capacity. (125 detectors & 125 modules per loop) DEVICE LEGEND Devices Current (Milliamps) Designator Part Number Description LightOuput 0 15cd 30cd 75cd 95cd 110cd 177cd A B C D E F G H I J K L M N 0 P Q R S T U V W X Y SB4U SB4U-LF GSA-SBT SIGA-AB4G-LF INT-7ATW INT-8ATW EG1F-HD EG1F-VM EG1F-HDVM EGCF-VM EGCF-VMH EGCF-HDVM EGCF-HDVMH G4LFWF-H G4LFWF-HVM G4HFWF-S7VMC GCHFWF-S7VMC INT-4ASW XXXX DHF-24120C C01224T XXXX XXXX XXXX XXXX Sounder Base for V Series Detectors 520Hz Sounder Base for V Series Detectors Sounder Base for PCOS Detectors 520Hz Sounder Base for PCOS Detectors WP Wall Mount Horn/Strobe WP Wall Mount Horn/Strobe Wall Mount Horn Wall Mount Strobe Wall Mount Horn/Strobe Ceiling Mount Strobe Ceiling Mount High Candela Strobe Ceiling Mount Horn/Strobe Ceiling Mount High Candela Horn/Strobe Wall Mount 520Hz Horn Wall Mount 520Hz Horn/Strobe Wall Mount Speaker/Strobe Ceiling Mount Speaker/Strobe Weatherproof Speaker/Strobe XXXX Magnetic Door Hold-Open Carbon Monoxide Detector XXXX XXXX XXXX XXXX 28 92 52 92 180 90 22 85 102 127 245 285 135 160 246 309 94 140 273 325 333 551 111 152 281 333 324 554 166 219 266 381 437 78 101 188 245 94 140 273 325 551 159 15 75 Z N/A END OF CIRCUIT Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP1 Circuit: NAC1 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.659 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 33 14 3.07 284 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 1.1.1 Q 30 0.140 33 20.064 0.336 0.0165 1.1.2 P 15 0.078 22 19.859 0.541 0.0265 1.1.3 P 15 0.078 17 19.708 0.692 0.0339 1.1.4 P 15 0.078 11 19.616 0.784 0.0384 1.1.5 P 15 0.078 6 19.569 0.831 0.0407 1.1.6 P 15 0.078 20 19.421 0.979 0.0480 1.1.7 P 30 0.101 19 19.289 1.111 0.0545 1.1.8 Q 30 0.140 29 19.106 1.294 0.0634 1.1.9 Q 30 0.140 17 19.013 1.387 0.0680 1.1.10 Q 15 0.094 31 18.871 1.529 0.0750 1.1.11 Q 15 0.094 17 18.803 1.597 0.0783 1.1.12 Q 30 0.140 19 18.737 1.663 0.0815 1.1.13 Q 30 0.140 18 18.691 1.709 0.0838 1.1.14 Q 30 0.140 35 18.631 1.769 0.0867 1.1.15 Q 30 0.140 23 18.611 1.789 0.0877 END Z 0.000 0 18.611 1.789 0.0877 END Z 0.000 0 18.611 1.789 0.0877 END Z 0.000 0 18.611 1.789 0.0877 END Z 0.000 0 18.611 1.789 0.0877 END Z 0.000 0 18.611 1.789 0.0877 END Z 0.000 0 18.611 1.789 0.0877 Totals: 1.659 317 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 8.77% Current: 1.659 Distance: 317 End Line Voltage: Voltage Drop:! 1.79 of 18.61 CIRCUIT IS WITHIN LIMITS Load Centering Method Percent Drop:7.91% Current:! 1.659 Distance: 317 End of Line Voltage: 18.79 Volta 9 a Dro 1.61 p:, End of Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 15.83% Current: 1.659 Distance:; 317 End of Line Voltage: 17.17 Voltage Drop: j 3.23 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP1 Circuit: NAC2 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.675 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 75 14 3.07 304 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 1.2.1 P 15 0.078 75 19.629 0.771 0.0378 1.2.2 Q 30 0.140 30 19.334 1.066 0.0522 1.2.3 P 15 0.078 31 19.057 1.343 0.0658 1.2.4 Q 75 0.273 25 18.845 1.555 0.0762 1.2.5 Q 30 0.140 43 18.553 1.847 0.0905 1.2.6 Q 75 0.273 38 18.328 2.072 0.1016 1.2.7 P 15 0.078 20 18.243 2.157 0.1057 1.2.8 P 15 0.078 30 18.130 2.270 0.1113 1.2.9 J 30 0.140 13 18.087 2.313 0.1134 1.2.10 J 30 0.140 16 18.048 2.352 0.1153 1.2.11 P 15 0.078 14 18.026 2.374 0.1164 1.2.12 P 15 0.078 17 18.007 2.393 0.1173 1.2.13 P 30 0.101 27 17.990 2.410 0.1181 END Z 0.000 0 17.990 2.410 0.1181 END Z 0.000 0 17.990 2.410 0.1181 END Z 0.000 0 17.990 2.410 0.1181 END Z 0.000 0 17.990 2.410 0.1181 END Z 0.000 0 17.990 2.410 0.1181 END Z 0.000 0 17.990 2.410 0.1181 END Z 0.000 0 17.990 2.410 0.1181 END Z 0.000 0 17.990 2.410 0.1181 T+I40:Q42otals: 1.675 379 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 11.81% Current: 1.675 Distance: 379 End Line Voltage: 17.99 Voltage Drop: 2.41 of CIRCUIT IS WITHIN LIMITS Percent Drop: 9.55% Load Centering Method Current: 1.675 379 18.45 Distance: Voltage Drop: End of Line Voltage: 1.95 CIRCUIT IS WITHIN LIMITS Percent Drop: 19.11% End of Line Method Current: 1.675 379 16.50 Distance: Voltage Drop: End of Line Voltage: 3.90 Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP1 Circuit: NAC3 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.773 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Ohms / V uaae 1000' 11 14 3.07 265 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 1.3.1 P 30 0.101 11 20.280 0.120 0.0059 1.3.2 Q 30 0.140 38 19.890 0.510 0.0250 1.3.3 H 15 0.085 28 19.627 0.773 0.0379 1.3.4 P 30 0.101 12 19.520 0.880 0.0431 1.3.5 Q 75 0.273 28 19.289 1.111 0.0545 1.3.6 Q 75 0.273 14 19.197 1.203 0.0590 1.3.7 P 15 0.078 30 19.049 1.351 0.0662 1.3.8 P 15 0.078 11 19.000 1.400 0.0686 1.3.9 H 15 0.085 22 18.913 1.487 0.0729 1.3.10 R 75 0.159 7 18.889 1.511 0.0741 1.3.11 R 75 0.159 41 18.789 1.611 0.0790 1.3.12 Q 30 0.140 23 18.755 1.645 0.0807 1.3.13 P 30 0.101 11 18.748 1.652 0.0810 END Z 0.000 0 18.748 1.652 0.0810 END Z 0.000 0 18.748 1.652 0.0810 END Z 0.000 0 18.748 1.652 0.0810 END Z 0.000 0 18.748 1.652 0.0810 END Z 0.000 0 18.748 1.652 0.0810 END Z 0.000 0 18.748 1.652 0.0810 END Z 0.000 0 18.748 1.652 0.0810 END Z 0.000 0 18.748 1.652 0.0810 Totals: 1.773 276 CIRCUIT IS WITHIN LIMITS( Percent Drop: Current: 1.773 8.10% Point to Point Method Distance: End Line Voltage: 276 18.75 Voltage Drop: 1.65 of Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 7.36% Current: 1.773 276 18.90 Distance: Voltage Drop: End of Line Voltage: 1.50 End Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 14.73% Current: 1.773 of Distance: 276 End Line Voltage: 17.40 Voltage Drop: 3.00 of Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP1 Circuit: NAC4 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guaae Ohms/ 1000' 0 14 3.07 0 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 Totals: 0 0 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Point to Point Method Current: 0 0 20.40 Distance: Voltage Drop: End of Line Voltage: 0.00 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 0 20.40 Distance: Voltage Drop: End of Line Voltage: 0.00 End of Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 Distance: 0 End Voltage Drop: 0.00 of Line Voltage: 20.40 Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP1 Battery Calculations Standy Circuit / Device Current Alarm Current Qty Total Standy Current Total Alarm Current Power Supply 70 70 1 70 70 NAC Power NAC1 0 1659 1 0 1659 NAC2 0 1675 1 0 1675 NAC3 0 1773 1 0 1773 NAC4 0 0 0 0 0 200 mA Aux Power Aux 0 0 0 0 0 Aux 0 0 0 0 0 Aux 0 0 0 0 0 TOTALS: 70 5177 Total Standy Current (Amps): 0.07 X 24 Hours: 1.68 Amphours in Standy Total Alarm Current (Amps): 5.177 X 15 Mins: 1.29 Amphours in Alarm 2.97 Required Amphours Required Amphours: +20% Safety 2.97 3'57 Total Margin Am hours p (2) 12V 8Ah Batteries Required. *Magnetic Door Holders are not included in the battery calculations. Power to these devices will be automatically disconnected upon Toss of NC power to reduce battery size. DEVICE LEGEND Devices Current (Milliamps) Designator Part Number Description Light Ouput 0 15cd 30cd 75cd 95cd 110cd 177cd A B C D E F G H I J K L M N 0 P Q R S T U V W X Y SB4U SB4U-LF GSA-SBT SIGA-AB4G-LF INT-7ATW INT-8ATW EG1F-HD EG1F-VM EG1F-HDVM EGCF-VM EGCF-VMH EGCF-HDVM EGCF-HDVMH G4LFWF-H G4LFWF-HVM G4HFWF-S7VMC GCHFWF-S7VMC INT-4ASW XXXX DHF -24120C C01224T XXXX XXXX XXXX XXXX Sounder Base for V Series Detectors 520Hz Sounder Base for V Series Detectors Sounder Base for PCOS Detectors 520Hz Sounder Base for PCOS Detectors WP Wall Mount Horn/Strobe WP Wall Mount Horn/Strobe Wall Mount Horn Wall Mount Strobe Wall Mount Horn/Strobe Ceiling Mount Strobe Ceiling Mount High Candela Strobe Ceiling Mount Horn/Strobe Ceiling Mount High Candela Horn/Strobe Wall Mount 520Hz Horn Wall Mount 520Hz Horn/Strobe Wall Mount Speaker/Strobe Ceiling Mount Speaker/Strobe Weatherproof Speaker/Strobe XXXX Magnetic Door Hold -Open Carbon Monoxide Detector XXXX XXXX XXXX XXXX 28 92 52 92 180 90 22 85 127 245 285 102 135 160 246 309 94 140 273 325 333 551 111 152 281 333 324 554 166 219 266 381 437 78 101 188 245 94 140 273 325 551 159 15 75 Z N/A END OF CIRCUIT Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP2 Circuit: NAC1 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0.82 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Ouaae Ohms/ 1000' 140 14 3.07 65 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 2.1.1 P 110 0.245 140 19.695 0.705 0.0346 2.1.2 P 110 0.245 19 19.628 0.772 0.0378 2.1.3 H 15 0.085 10 19.608 0.792 0.0388 2.1.4 P 110 0.245 36 19.554 0.846 0.0415 END Z 0.000 0 19.554 0.846 0.0415 END Z 0.000 0 19.554 0.846 0.0415 END Z 0.000 0 19.554 0.846 0.0415 END Z 0.000 0 19.554 0.846 0.0415 END Z 0.000 0 19.554 0.846 0.0415 END Z 0.000 0 19.554 0.846 0.0415 END Z 0.000 0 19.554 0.846 0.0415 END Z 0.000 0 19.554 0.846 0.0415 END Z 0.000 0 19.554 0.846 0.0415 END Z 0.000 0 19.554 0.846 0.0415 END Z 0.000 0 19.554 0.846 0.0415 END Z 0.000 0 19.554 0.846 0.0415 END Z 0.000 0 19.554 0.846 0.0415 END Z 0.000 0 19.554 0.846 0.0415 END Z 0.000 0 19.554 0.846 0.0415 END Z 0.000 0 19.554 0.846 0.0415 END Z 0.000 0 19.554 0.846 0.0415 Totals: 0.82 205 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 4.15% Current: 0.82 Distance: 205 End Line Voltage: Voltage Drop:', 0.85 of 19.55 CIRCUIT IS WITHIN LIMITS Load Centering Method Percent Drop: 2.53% Current: 0.82 Distance:' 205 End Line Voltage: 19.88 Voltage Drop: 0.52 of End Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 5.06% Current: 0.82 of Distance: 205 End Line Voltage: Voltage Drop: 1.03 of 19.37 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP2 Circuit: NAC2 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guage Ohms/ 1000' 0 14 3.07 0 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 T+I40:Q42otals: 0 0 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Point to Point Method Current: 0 Distance: 0 Voltage Drop: End of Line Voltage: 20.40 0.00 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Load Centering Method Current: 0 0 20.40 Distance: Voltage Drop: End of Line Voltage: 0.00 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% End of Line Method Current: 0 0 20.40 Distance: Voltage Drop: End of Line Voltage: 0.00 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP2 Circuit: NAC3 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.555 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guaae Ohms / 1000" 11 14 3.07 129 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 2.3.1 P 110 0.245 11 20.295 0.105 0.0051 2.3.2 P 110 0.245 9 20.223 0.177 0.0087 2.3.3 P 110 0.245 34 20.000 0.400 0.0196 2.3.4 P 110 0.245 23 19.884 0.516 0.0253 2.3.5 P 110 0.245 25 19.796 0.604 0.0296 2.3.6 P 110 0.245 24 19.748 0.652 0.0320 2.3.7 H 15 0.085 14 19.740 0.660 0.0323 END Z 0.000 0 19.740 0.660 0.0323 END Z 0.000 0 19.740 0.660 0.0323 END Z 0.000 0 19.740 0.660 0.0323 END Z 0.000 0 19.740 0.660 0.0323 END Z 0.000 0 19.740 0.660 0.0323 END Z 0.000 0 19.740 0.660 0.0323 END Z 0.000 0 19.740 0.660 0.0323 END Z 0.000 0 19.740 0.660 0.0323 END Z 0.000 0 19.740 0.660 0.0323 END Z 0.000 0 19.740 0.660 0.0323 END Z 0.000 0 19.740 0.660 0.0323 END Z 0.000 0 19.740 0.660 0.0323 END Z 0.000 0 19.740 0.660 0.0323 END Z 0.000 0 19.740 0.660 0.0323 Totals: 1.555 140 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 3.23% Current: 1.555 Distance: 140 Voltage Drop: End of Line Voltage: 19.74 0.66 CIRCUIT IS WITHIN LIMITS Percent Drop: 3.28% Load Centering Method Current: 1.555 Distance: Voltage Drop: 140 End of Line Voltage: 19.73 0.67 End of Line Method CIRCUIT IS WITHIN LIMITS' Percent Drop: 6.55% Current: 1.555 Distance: 140 End Line Voltage Drop: 1.34 "� of Voltage: 19.06 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP2 Circuit: NAC4 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0.828 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Ouaae Ohms/ 1000' 7 14 3.07 195 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 2.4.1 D 0.092 7 20.364 0.036 0.0017 2.4.2 D 0.092 20 20.274 0.126 0.0062 2.4.3 D 0.092 15 20.215 0.185 0.0091 2.4.4 D 0.092 30 20.113 0.287 0.0141 2.4.5 D 0.092 17 20.065 0.335 0.0164 2.4.6 D 0.092 26 20.006 0.394 0.0193 2.4.7 D 0.092 32 19.952 0.448 0.0220 2.4.8 D 0.092 27 19.922 0.478 0.0235 2.4.9 D 0.092 28 19.906 0.494 0.0242 END Z 0.000 0 19.906 0.494 0.0242 END Z 0.000 0 19.906 0.494 0.0242 END Z 0.000 0 19.906 0.494 0.0242 END Z 0.000 0 19.906 0.494 0.0242 END Z 0.000 0 19.906 0.494 0.0242 END Z 0.000 0 19.906 0.494 0.0242 END Z 0.000 0 19.906 0.494 0.0242 END Z 0.000 0 19.906 0.494 0.0242 END Z 0.000 0 19.906 0.494 0.0242 END Z 0.000 0 19.906 0.494 0.0242 END Z 0.000 0 19.906 0.494 0.0242 END Z 0.000 0 19.906 0.494 0.0242 Totals: 0.828 202 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 2.42% Current: 0.828 Distance: 202 Voltage Drop: End of Line Voltage: 19.91 0.49 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 2.52% Current: 0.828 Distance: 202 Voltage Drop: End of Line Voltage: 19.89 0.51 End of Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 5.03% Current: 0.828 202 Distance: Voltage Drop: End of Line Voltage: 19.37 1.03 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP2 Battery Calculations Standy Circuit / Device Current Alarm Current Qty Total Standy Current Total Alarm Current Power Supply 70 70 1 70 70 NAC Power NAC1 0 820 1 0 820 NAC2 0 0 0 0 0 NAC3 0 1555 1 0 1555 NAC4 54 828 1 54 0 200 mA Aux Power Aux 0 0 0 0 0 Aux 0 0 0 0 0 Aux 0 0 0 0 0 TOTALS: 124 2445 Total Standy Current (Amps): 0.124 X 24 Hours: 2.976 Amphours in Standy Total Alarm Current (Amps): 2.445 X 15 Mins: 0.61 Amphours in Alarm 3.59 Required Amphours +20% Safety Total Required Amphours: 3.59 Margin 4.30 Amp hours (2) 12V 8Ah Batteries Required. "Magnetic Door Holders are not included in the battery calculations. Power to these devices will be automatically disconnected upon loss of A/C power to reduce battery size. DEVICE LEGEND Devices Current (Milliamps) Designator Part Number Description Light Ouput 0 15cd 30cd 75cd 95cd 110cd 177cd A B C D E F G H I J K L M N 0 P Q R S T U V W X Y SB4U SB4U-LF GSA-SBT SIGA-AB4G-LF INT-7ATW INT-8ATW EG1F-HD EG1F-VM EG1F-HDVM EGCF-VM EGCF-VMH EGCF-HDVM EGCF-HDVMH G4LFWF-H G4LFWF-HVM G4HFWF-S7VMC GCHFWF-S7VMC INT-4ASW XXXX DHF -24120C CO1224T XXXX )(XXX XXXX XXXX Sounder Base for V Series Detectors 520Hz Sounder Base for V Series Detectors Sounder Base for PCOS Detectors 520Hz Sounder Base for PCOS Detectors WP Wall Mount Horn/Strobe WP Wall Mount Horn/Strobe Wall Mount Horn Wall Mount Strobe Wall Mount Horn/Strobe Ceiling Mount Strobe Ceiling Mount High Candela Strobe Ceiling Mount Horn/Strobe Ceiling Mount High Candela Horn/Strobe Wall Mount 520Hz Horn Wall Mount 520Hz Horn/Strobe Wall Mount Speaker/Strobe Ceiling Mount Speaker/Strobe Weatherproof Speaker/Strobe XXXX Magnetic Door Hold -Open Carbon Monoxide Detector XXXX XXXX XXXX XXXX 28 92 52 92 180 90 22 85 102 127 135 245 160 246 285 309 94 140 273 325 333 551 111 152 281 333 324 554 166 219 266 381 437 78 101 188 245 94 140 273 325 551 159 15 75 Z N/A END OF CIRCUIT Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP3 Circuit: NAC1 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.065 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 33 14 3.07 69 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 3.1.1 P 110 0.245 33 20.184 0.216 0.0106 3.1.2 P 110 0.245 23 20.068 0.332 0.0163 3.1.3 P 110 0.245 9 20.037 0.363 0.0178 3.1.4 H 15 0.085 8 20.020 0.380 0.0186 3.1.5 P 110 0.245 29 19.977 0.423 0.0207 END Z 0.000 0 19.977 0.423 0.0207 END Z 0.000 0 19.977 0.423 0.0207 END Z 0.000 0 19.977 0.423 0.0207 END Z 0.000 0 19.977 0.423 0.0207 END Z 0.000 0 19.977 0.423 0.0207 END Z 0.000 0 19.977 0.423 0.0207 END Z 0.000 0 19.977 0.423 0.0207 END Z 0.000 0 19.977 0.423 0.0207 END Z 0.000 0 19.977 0.423 0.0207 END Z 0.000 0 19.977 0.423 0.0207 END Z 0.000 0 19.977 0.423 0.0207 END Z 0.000 0 19.977 0.423 0.0207 END Z 0.000 0 19.977 0.423 0.0207 END Z 0.000 0 19.977 0.423 0.0207 END Z 0.000 0 19.977 0.423 0.0207 END Z 0.000 0 19.977 0.423 0.0207 Totals: 1.065 102 CIRCUIT IS WITHIN LIMITS Percent Drop: 2.07% Point to Point Method Current:' 1.065 102 19.98 Distance:1 Voltage Drop:, End of Line Voltage: 0.42 CIRCUIT IS WITHIN LIMITS Percent Drop: 1.63% Load Centering Method Current: 1.065 Distance: Voltage Drop: 102 End of Line Voltage: 20.07 0.33 End of Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 3.27% Current:', 1.065 Distance: 1 102 End Voltage Drop: 0.67 of Line Voltage: 19.73 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP3 Circuit: NAC2 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.47 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guage Ohms/ 1000' 80 14 3.07 103 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 3.2.1 P 110 0.245 80 19.678 0.722 0.0354 3.2.2 P 110 0.245 21 19.520 0.880 0.0431 3.2.3 P 110 0.245 22 19.388 1.012 0.0496 3.2.4 P 110 0.245 20 19.297 1.103 0.0541 3.2.5 P 110 0.245 19 19.240 1.160 0.0569 3.2.6 P 110 0.245 21 19.209 1.191 0.0584 END Z 0.000 0 19.209 1.191 0.0584 END Z 0.000 0 19.209 1.191 0.0584 END Z 0.000 0 19.209 1.191 0.0584 END Z 0.000 0 19.209 1.191 0.0584 END Z 0.000 0 19.209 1.191 0.0584 END Z 0.000 0 19.209 1.191 0.0584 END Z 0.000 0 19.209 1.191 0.0584 END Z 0.000 0 19.209 1.191 0.0584 END Z 0.000 0 19.209 1.191 0.0584 END Z 0.000 0 19.209 1.191 0.0584 END Z 0.000 0 19.209 1.191 0.0584 END Z 0.000 0 19.209 1.191 0.0584 END Z 0.000 0 19.209 1.191 0.0584 END Z 0.000 0 19.209 1.191 0.0584 END Z 0.000 0 19.209 1.191 0.0584 T+I40:Q42otals: 1.47 183 CIRCUIT IS WITHIN LIMITS Percent Drop: 5.84% Point to Point Method Current: 1.47 183 19.21 Distance: Voltage Drop: End of Line Voltage: 1.19 CIRCUIT IS WITHIN LIMITS Percent Drop: 4.05% Load Centering Method Current: 1.47 183 19.57 Distance: Voltage Drop: End of Line Voltage: 0.83 CIRCUIT IS WITHIN LIMITS Percent Drop: 8.10% End Line Method Current: 1.47 of Distance: 183 Voltage Drop: End of Line Voltage: 18.75 1.65 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP3 Circuit: NAC3 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0.413 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Ouaae Ohms/ 1000' 9 14 3.07 138 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 3.3.1 P 30 0.101 9 20.377 0.023 0.0011 3.3.2 P 15 0.078 3 20.371 0.029 0.0014 3.3.3 P 15 0.078 52 20.297 0.103 0.0051 3.3.4 P 15 0.078 52 20.247 0.153 0.0075 3.3.5 P 15 0.078 31 20.232 0.168 0.0082 END Z 0.000 0 20.232 0.168 0.0082 END Z 0.000 0 20.232 0.168 0.0082 END Z 0.000 0 20.232 0.168 0.0082 END Z 0.000 0 20.232 0.168 0.0082 END Z 0.000 0 20.232 0.168 0.0082 END Z 0.000 0 20.232 0.168 0.0082 END Z 0.000 0 20.232 0.168 0.0082 END Z 0.000 0 20.232 0.168 0.0082 END Z 0.000 0 20.232 0.168 0.0082 END Z 0.000 0 20.232 0.168 0.0082 END Z 0.000 0 20.232 0.168 0.0082 END Z 0.000 0 20.232 0.168 0.0082 END Z 0.000 0 20.232 0.168 0.0082 END Z 0.000 0 20.232 0.168 0.0082 END Z 0.000 0 20.232 0.168 0.0082 END Z 0.000 0 20.232 0.168 0.0082 Totals: 0.413 147 CIRCUIT IS WITHIN LIMITS 0.82% Percent Drop: Point to Point Method Current: 0.413 147 End 20.23 Distance: Voltage Drop: of Line Voltage: 0.17 Load Centering Method CIRCUIT IS WITHIN LIMITS 0.91% Current: Percent Drop: 0.413 I Distance: 147 End Line Voltage Drop: of Voltage: 0.19 20.21 End of Line Method CIRCUIT IS WITHIN LIMITS 1.83% Current: Percent Drop: 0.413 Distance: 147 End Line Voltage: Voltage Drop: of 0.37 20.03 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP3 Circuit: NAC4 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0.92 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guage Ohms/ 1000' 37 14 3.07 186 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 3.4.1 D 0.092 37 20.191 0.209 0.0102 3.4.2 D 0.092 22 20.079 0.321 0.0157 3.4.3 D 0.092 21 19.984 0.416 0.0204 3.4.4 D 0.092 18 19.913 0.487 0.0239 3.4.5 D 0.092 20 19.845 0.555 0.0272 3.4.6 D 0.092 25 19.775 0.625 0.0307 3.4.7 D 0.092 21 19.727 0.673 0.0330 3.4.8 D 0.092 19 19.695 0.705 0.0346 3.4.9 D 0.092 19 19.674 0.726 0.0356 3.4.10 D 0.092 21 19.662 0.738 0.0362 END Z 0.000 0 19.662 0.738 0.0362 END Z 0.000 0 19.662 0.738 0.0362 END Z 0.000 0 19.662 0.738 0.0362 END Z 0.000 0 19.662 0.738 0.0362 END Z 0.000 0 19.662 0.738 0.0362 END Z 0.000 0 19.662 0.738 0.0362 END Z 0.000 0 19.662 0.738 0.0362 END Z 0.000 0 19.662 0.738 0.0362 END Z 0.000 0 19.662 0.738 0.0362 END Z 0.000 0 19.662 0.738 0.0362 END Z 0.000 0 19.662 0.738 0.0362 Totals: 0.92 223 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 3.62% Current: 0.92 Distance: 223 Voltage Drop: End of Line Voltage: 19.66 0.74 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 3.09% Current: 0.92 Distance: 223 Voltage Drop: End of Line Voltage: 19.77 0.63 End Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 6.17% Current: 0.92 of Distance: 223 Voltage Drop: End of Line Voltage: 19.14 1.26 Prosect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP3 Battery Calculations Standy Circuit / Device Current Alarm Current Qty Total Standy Current Total Alarm Current Power Supply 70 70 1 70 70 NAC Power NAC1 0 1065 1 0 1065 NAC2 0 1470 1 0 1470 NAC3 0 413 1 0 413 NAC4 60 920 1 60 0 200 mA Aux Power Aux 0 0 0 0 0 Aux 0 0 0 0 0 Aux 0 0 0 0 0 TOTALS: 130 3018 Total Standy Current (Amps): 0.13 X 24 Hours: 3.12 Amphours in Standy Total Alarm Current (Amps): 3.018 X 15 Mins: 0.75 Amphours in Alarm 3.87 Required Amphours Required Amphours: +20% Safety 3.87 4.65 Total Margin Arn hours p (2) 12V 8Ah Batteries Required. *Magnetic Door Holders are not included in the battery calculations. Power to these devices will be automatically disconnected upon Toss of NC power to reduce battery size. DEVICE LEGEND Devices Current (Milliamps) Designator Part Number Description LightOuput 0 15cd 30cd 75cd 95cd 110cd 177cd A B C D E F G H I J K L M N 0 P Q R S T U V W X Y SB4U SB4U-LF GSA-SBT SIGA-AB4G-LF INT-7ATW INT-8ATW EG1F-HD EG1F-VM EG1F-HDVM EGCF-VM EGCF-VMH EGCF-HDVM EGCF-HDVMH G4LFWF-H G4LFWF-HVM G4HFWF-S7VMC GCHFWF-S7VMC INT-4ASW XXXX DHF -24120C C01224T XXXX XXXX XXXX XXXX Sounder Base for V Series Detectors 520Hz Sounder Base for V Series Detectors Sounder Base for PCOS Detectors 520Hz Sounder Base for PCOS Detectors WP Wall Mount Horn/Strobe WP Wall Mount Horn/Strobe Wall Mount Horn Wall Mount Strobe Wall Mount Horn/Strobe Ceiling Mount Strobe Ceiling Mount High Candela Strobe Ceiling Mount Horn/Strobe Ceiling Mount High Candela Horn/Strobe Wall Mount 520Hz Horn Wall Mount 520Hz Horn/Strobe Wall Mount Speaker/Strobe Ceiling Mount Speaker/Strobe Weatherproof Speaker/Strobe XXXX Magnetic Door Hold -Open Carbon Monoxide Detector XXXX XXXX XXXX XXXX 28 92 52 92 180 90 22 85 127 245 285 102 135 160 246 309 94 140 273 325 333 551 111 152 281 333 324 554 166 219 266 381 437 78 101 188 245 94 140 273 325 551 159 15 75 Z N/A END OF CIRCUIT Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP4 Circuit: NAC1 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.225 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 152 14 3.07 78 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 4.1.1 P 110 0.245 152 19.257 1.143 0.0560 4.1.2 P 110 0.245 20 19.136 1.264 0.0619 4.1.3 P 110 0.245 10 19.091 1.309 0.0642 4.1.4 P 110 0.245 42 18.965 1.435 0.0703 4.1.5 P 110 0.245 6 18.956 1.444 0.0708 END Z 0.000 0 18.956 1.444 0.0708 END Z 0.000 0 18.956 1.444 0.0708 END Z 0.000 0 18.956 1.444 0.0708 END Z 0.000 0 18.956 1.444 0.0708 END Z 0.000 0 18.956 1.444 0.0708 END Z 0.000 0 18.956 1.444 0.0708 END Z 0.000 0 18.956 1.444 0.0708 END Z 0.000 0 18.956 1.444 0.0708 END Z 0.000 0 18.956 1.444 0.0708 END Z 0.000 0 18.956 1.444 0.0708 END Z 0.000 0 18.956 1.444 0.0708 END Z 0.000 0 18.956 1.444 0.0708 END Z 0.000 0 18.956 1.444 0.0708 END Z 0.000 0 18.956 1.444 0.0708 END Z 0.000 0 18.956 1.444 0.0708 END Z 0.000 0 18.956 1.444 0.0708 Totals: 1.225 230 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 7.08% Current: 1.225 Distance: 230 End Line Voltage: 18.96 Voltage Drop: 1.44 of Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 4.24% Current: 1.225 Distance: 230 Voltage Drop: End of Line Voltage: 19.54 0.86 End Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 8.48% Current: 1.225 of Distance: 230 End Line Voltage: Voltage Drop: 1.73 of 18.67 Prosect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP4 Circuit: NAC2 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.555 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guage Ohms/ 1000' 103 14 3.07 128 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 4.2.1 P 110 0.245 103 19.417 0.983 0.0482 4.2.2 P 110 0.245 26 19.207 1.193 0.0585 4.2.3 P 110 0.245 17 19.096 1.304 0.0639 4.2.4 P 110 0.245 37 18.910 1.490 0.0730 4.2.5 P 110 0.245 17 18.850 1.550 0.0760 4.2.6 H 15 0.085 8 18.834 1.566 0.0768 4.2.7 P 110 0.245 23 18.799 1.601 0.0785 END Z 0.000 0 18.799 1.601 0.0785 END Z 0.000 0 18.799 1.601 0.0785 END Z 0.000 0 18.799 1.601 0.0785 END Z 0.000 0 18.799 1.601 0.0785 END Z 0.000 0 18.799 1.601 0.0785 END Z 0.000 0 18.799 1.601 0.0785 END Z 0.000 0 18.799 1.601 0.0785 END Z 0.000 0 18.799 1.601 0.0785 END Z 0.000 0 18.799 1.601 0.0785 END Z 0.000 0 18.799 1.601 0.0785 END Z 0.000 0 18.799 1.601 0.0785 END Z 0.000 0 18.799 1.601 0.0785 END Z 0.000 0 18.799 1.601 0.0785 END Z 0.000 0 18.799 1.601 0.0785 T+I40:Q42otals: 1.555 231 CIRCUIT IS WITHIN LIMITS Percent Drop: 7.85% Point to Point Method Current: 1.555 231 18.80 Distance: Voltage Drop: End of Line Voltage: 1.60 CIRCUIT IS WITHIN LIMITS Percent Drop: 5.41% Load Centering Method Current: 1.555 231 19.30 Distance: Voltage Drop: End of Line Voltage: 1.10 CIRCUIT IS WITHIN LIMITS Percent Drop: 10.81% End of Line Method Current: 1.555 231 18.19 Distance: Voltage Drop: End of Line Voltage: 2.21 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP4 Circuit: NAC3 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.225 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guaae Ohms/ 1000' 15 14 3.07 94 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 4.3.1 P 110 0.245 15 20.287 0.113 0.0055 4.3.2 P 110 0.245 23 20.149 0.251 0.0123 4.3.3 P 110 0.245 33 20.000 0.400 0.0196 4.3.4 P 110 0.245 9 19.973 0.427 0.0209 4.3.5 P 110 0.245 29 19.929 0.471 0.0231 END Z 0.000 0 19.929 0.471 0.0231 END Z 0.000 0 19.929 0.471 0.0231 END Z 0.000 0 19.929 0.471 0.0231 END Z 0.000 0 19.929 0.471 0.0231 END Z 0.000 0 19.929 0.471 0.0231 END Z 0.000 0 19.929 0.471 0.0231 END Z 0.000 0 19.929 0.471 0.0231 END Z 0.000 0 19.929 0.471 0.0231 END Z 0.000 0 19.929 0.471 0.0231 END Z 0.000 0 19.929 0.471 0.0231 END Z 0.000 0 19.929 0.471 0.0231 END Z 0.000 0 19.929 0.471 0.0231 END Z 0.000 0 19.929 0.471 0.0231 END Z 0.000 0 19.929 0.471 0.0231 END Z 0.000 0 19.929 0.471 0.0231 END Z 0.000 0 19.929 0.471 0.0231 Totals: 1.225 109 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 2.31% Current: 1.225 Distance: 109 Voltage Drop: End of Line Voltage: 19.93 0.47 CIRCUIT IS WITHIN LIMITS Percent Drop: 2.01% Load Centering Method Current: 1.225 109 19.99 Distance: Voltage Drop: End of Line Voltage: 0.41 CIRCUIT IS WITHIN LIMITS Percent End of Line Method Current: 1.225 Drop: 4.02% Distance: Voltage Drop: 109 1 End of Line Voltage: 19.58 ---1 0.82 Proiect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP4 Circuit: NAC4 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.012 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guaoe Ohms/ 1000' 17 14 3.07 239 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 4.4.1 D 0.092 17 20.294 0.106 0.0052 4.4.2 D 0.092 25 20.153 0.247 0.0121 4.4.3 D 0.092 23 20.036 0.364 0.0178 4.4.4 D 0.092 22 19.937 0.463 0.0227 4.4.5 D 0.092 22 19.850 0.550 0.0270 4.4.6 D 0.092 26 19.762 0.638 0.0313 4.4.7 D 0.092 17 19.714 0.686 0.0336 4.4.8 D 0.092 24 19.659 0.741 0.0363 4.4.9 D 0.092 27 19.614 0.786 0.0385 4.4.10 D 0.092 28 19.582 0.818 0.0401 4.4.11 D 0.092 25 19.568 0.832 0.0408 END Z 0.000 0 19.568 0.832 0.0408 END Z 0.000 0 19.568 0.832 0.0408 END Z 0.000 0 19.568 0.832 0.0408 END Z 0.000 0 19.568 0.832 0.0408 END Z 0.000 0 19.568 0.832 0.0408 END Z 0.000 0 19.568 0.832 0.0408 END Z 0.000 0 19.568 0.832 0.0408 END Z 0.000 0 19.568 0.832 0.0408 END Z 0.000 0 19.568 0.832 0.0408 END Z 0.000 0 19.568 0.832 0.0408 Totals: 1.012 256 CIRCUIT IS WITHIN LIMITS Percent Drop: 4.08% Current: 1.012 Point to Point Method 256 19.57 Distance: Voltage Drop: End of Line Voltage: 0.83 CIRCUIT IS WITHIN LIMITS Percent Drop: 3.90% Current: 1.012 Load Centering Method 256 19.60 Distance: Voltage Drop: End of Line Voltage: 0.80 CIRCUIT IS WITHIN LIMITS Percent Drop: 7.80% Current: 1.012 End of Line Method Distance: 256 Voltage Drop: End of Line Voltage: 18.81 1.59 Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP4 Battery Calculations Standy Circuit / Device Current Alarm Current Qty Total Standy Current Total Alarm Current Power Supply 70 70 1 70 70 NAC Power NAC1 0 1225 1 0 1225 NAC2 0 1555 1 0 1555 NAC3 0 1225 1 0 1225 NAC4 66 1012 1 66 0 200 mA Aux Power Aux 0 0 0 0 0 Aux 0 0 0 0 0 Aux 0 0 0 0 0 TOTALS: 136 4075 Total Standy Current (Amps): 0.136 X 24 Hours: 3.264 Amphours in Standy Total Alarm Current (Amps): 4.075 X 15 Mins: 1.02 Amphours in Alarm 4.28 Required Amphours Required Amphours: +20% Safety 4.28 5.14 Total Margin Am hours p (2) 12V 8Ah Batteries Required. *Magnetic Door Holders are not included in the battery calculations. Power to these devices will be automatically disconnected upon loss of A/C power to reduce battery size. DEVICE LEGEND Devices Current (Milliamps) Designator Part Number Description Light ouput 0 15cd 30cd 75cd 95cd 110cd 177cd A B C D E F G H I J K L M N 0 P Q R S T U V W X Y SB4U SB4U-LF GSA-SBT SIGA-AB4G-LF INT-7ATW INT-8ATW EG1F-HD EG1 F -VM EG1F-HDVM EGCF-VM EGCF-VMH EGCF-HDVM EGCF-HDVMH G4LFWF-H G4LFWF-HVM G4HFWF-S7VMC GCHFWF-S7VMC INT-4ASW XXXX DHF -24120C CO1224T XXXX XXXX XXXX XXXX Sounder Base for V Series Detectors 520Hz Sounder Base for V Series Detectors Sounder Base for PCOS Detectors 520Hz Sounder Base for PCOS Detectors WP Wall Mount Horn/Strobe WP Wall Mount Horn/Strobe Wall Mount Horn Wall Mount Strobe Wall Mount Horn/Strobe Ceiling Mount Strobe Ceiling Mount High Candela Strobe Ceiling Mount Horn/Strobe Ceiling Mount High Candela Horn/Strobe Wall Mount 520Hz Horn Wall Mount 520Hz Horn/Strobe Wall Mount Speaker/Strobe Ceiling Mount Speaker/Strobe Weatherproof Speaker/Strobe XXXX Magnetic Door Hold -Open Carbon Monoxide Detector XXXX XXXX XXXX XXXX 28 92 52 92 180 90 22 85 102 127 135 245 160 246 285 309 94 140 273 325 333 551 111 152 281 333 324 554 166 219 266 381 437 78 101 188 245 94 140 273 325 551 159 15 75 Z N/A END OF CIRCUIT Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP5 Circuit: NAC1 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 f 1.47 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guaae Ohms/ 1000' 38 14 3.07 98 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 5.1.1 P 110 0.245 38 20.057 0.343 0.0168 5.1.2 P 110 0.245 17 19.929 0.471 0.0231 5.1.3 P 110 0.245 24 19.785 0.615 0.0302 5.1.4 P 110 0.245 16 19.713 0.687 0.0337 5.1.5 P 110 0.245 24 19.640 0.760 0.0372 5.1.6 P 110 0.245 17 19.615 0.785 0.0385 END Z 0.000 0 19.615 0.785 0.0385 END Z 0.000 0 19.615 0.785 0.0385 END Z 0.000 0 19.615 0.785 0.0385 END Z 0.000 0 19.615 0.785 0.0385 END Z 0.000 0 19.615 0.785 0.0385 END Z 0.000 0 19.615 0.785 0.0385 END Z 0.000 0 19.615 0.785 0.0385 END Z 0.000 0 19.615 0.785 0.0385 END Z 0.000 0 19.615 0.785 0.0385 END Z 0.000 0 19.615 0.785 0.0385 END Z 0.000 0 19.615 0.785 0.0385 END Z 0.000 0 19.615 0.785 0.0385 END Z 0.000 0 19.615 0.785 0.0385 END Z 0.000 0 19.615 0.785 0.0385 END Z 0.000 0 19.615 0.785 0.0385 Totals: 1.47 136 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 3.85% Current:, 1.47 Distance: 136 19.61 End of Line Voltage: Voltage Drop:; 0.79 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 3.01% Current: 1.47 Distance: 136 19.79 End of Line Voltage: Voltage Drop: 0.61 End Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 6.02% Current: 1.47 of Distance: 136 End Line Voltage: 19.17 Volta 9 e Dro 1.23 p:, of Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP5 Circuit: NAC2 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.47 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guage Ohms/ 1000' 185 14 3.07 76 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 5.2.1 P 110 0.245 185 18.730 1.670 0.0819 5.2.2 P 110 0.245 22 18.565 1.835 0.0900 5.2.3 P 110 0.245 9 18.511 1.889 0.0926 5.2.4 P 110 0.245 29 18.380 2.020 0.0990 5.2.5 P 110 0.245 7 18.359 2.041 0.1001 5.2.6 P 110 0.245 9 18.345 2.055 0.1007 END Z 0.000 0 18.345 2.055 0.1007 END Z 0.000 0 18.345 2.055 0.1007 END Z 0.000 0 18.345 2.055 0.1007 END Z 0.000 0 18.345 2.055 0.1007 END Z 0.000 0 18.345 2.055 0.1007 END Z 0.000 0 18.345 2.055 0.1007 END Z 0.000 0 18.345 2.055 0.1007 END Z 0.000 0 18.345 2.055 0.1007 END Z 0.000 0 18.345 2.055 0.1007 END Z 0.000 0 18.345 2.055 0.1007 END Z 0.000 0 18.345 2.055 0.1007 END Z 0.000 0 18.345 2.055 0.1007 END Z 0.000 0 18.345 2.055 0.1007 END Z 0.000 0 18.345 2.055 0.1007 END Z 0.000 0 18.345 2.055 0.1007 T+140:Q42otals: 1.47 261 CIRCUIT IS WITHIN LIMITS Percent Drop: 10.07% Point to Point Method Current: 1.47 261 Distance: Voltage Drop: End of Line Voltage: 18.35 2.05 CIRCUIT IS WITHIN LIMITS Percent Drop: 5.77% Load Centering Method Current: 1.47 261 19.22 Distance: Voltage Drop: End of Line Voltage: 1.18 CIRCUIT IS WITHIN LIMITS Percent Drop: 11.55% End of Line Method Current: 1.47 261 18.04 Distance: Voltage Drop: End of Line Voltage: 2.36 Proiect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP5 Circuit: NAC3 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.555 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guaae Ohms/ 1000' 64 1 14 3.07 158 i 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 5.3.1 P 110 0.245 64 19.789 0.611 0.0300 5.3.2 P 110 0.245 9 19.717 0.683 0.0335 5.3.3 H 15 0.085 7 19.671 0.729 0.0357 5.3.4 P 110 0.245 20 19.550 0.850 0.0416 5.3.5 P 110 0.245 19 19.465 0.935 0.0458 5.3.6 P 110 0.245 23 19.395 1.005 0.0492 5.3.7 P 110 0.245 80 19.275 1.125 0.0551 END Z 0.000 0 19.275 1.125 0.0551 END Z 0.000 0 19.275 1.125 0.0551 END Z 0.000 0 19.275 1.125 0.0551 END Z 0.000 0 19.275 1.125 0.0551 END Z 0.000 0 19.275 1.125 0.0551 END Z 0.000 0 19.275 1.125 0.0551 END Z 0.000 0 19.275 1.125 0.0551 END Z 0.000 0 19.275 1.125 0.0551 END Z 0.000 0 19.275 1.125 0.0551 END Z 0.000 0 19.275 1.125 0.0551 END Z 0.000 0 19.275 1.125 0.0551 END Z 0.000 0 19.275 1.125 0.0551 END Z 0.000 0 19.275 1.125 0.0551 END Z 0.000 0 19.275 1.125 0.0551 Totals: 1.555 222 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent 5.51% Current: Drop: 1.555 Distance: 222 End Line Voltage: Voltage Drop: 19.28 of 1.12 CIRCUIT IS WITHIN LIMITS 5.20% Percent Drop: Load Centering Method Current: 1.555 222 End Line Voltage: 19.34 Distance: Voltage Drop: of 1.06 End Line Method CIRCUIT IS WITHIN LIMITS Percent 10.39% Current: Drop: 1.555 of Distance: 222 End Line Voltage: Voltage Drop: of 2.12 18.28 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP5 Circuit: NAC4 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.012 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guaae Ohms / 1000' 37 14 3.07 212 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 5.4.1 D 0.092 37 20.170 0.230 0.0113 5.4.2 D 0.092 17 20.074 0.326 0.0160 5.4.3 D 0.092 24 19.952 0.448 0.0220 5.4.4 D 0.092 16 19.880 0.520 0.0255 5.4.5 D 0.092 24 19.785 0.615 0.0302 5.4.6 D 0.092 17 19.727 0.673 0.0330 5.4.7 D 0.092 19 19.674 0.726 0.0356 5.4.8 D 0.092 24 19.619 0.781 0.0383 5.4.9 D 0.092 22 19.582 0.818 0.0401 5.4.10 D 0.092 29 19.549 0.851 0.0417 5.4.11 D 0.092 20 19.538 0.862 0.0423 END Z 0.000 0 19.538 0.862 0.0423 END Z 0.000 0 19.538 0.862 0.0423 END Z 0.000 0 19.538 0.862 0.0423 END Z 0.000 0 19.538 0.862 0.0423 END Z 0.000 0 19.538 0.862 0.0423 END Z 0.000 0 19.538 0.862 0.0423 END Z 0.000 0 19.538 0.862 0.0423 END Z 0.000 0 19.538 0.862 0.0423 END Z 0.000 0 19.538 0.862 0.0423 END Z 0.000 0 19.538 0.862 0.0423 Totals: 1.012 249 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 4.23% Current: 1.012 Distance: 249 Voltage Drop: End of Line Voltage: 19.54 0.86 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 3.79% Current: 1.012 249 19.63 Distance: Voltage Drop: End of Line Voltage: 0.77 End Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 7.58% Current: 1.012 of Distance: 249 Voltage Drop: End of Line Voltage: 18.85 1.55 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP5 Battery Calculations Standy Circuit / Device Current Alarm Current Qty Total Standy Current Total Alarm Current Power Supply 70 70 1 70 70 NAC Power NAC1 0 1470 1 0 1470 NAC2 0 1470 1 0 1470 NAC3 0 1555 1 0 1555 NAC4 66 1012 1 66 0 200 mA Aux Power Aux 0 0 0 0 0 Aux 0 0 0 0 0 Aux 0 0 0 0 0 TOTALS: 136 4565 Total Standy Current (Amps): 0.136 X 24 Hours: 3.264 Amphours in Standy Total Alarm Current (Amps): 4.565 X 15 Mins: 1.14 Amphours in Alarm 4.41 Required Amphours Required Amphours: +20% Safety 4.41 5'29 Total Margin Am hours p (2) 12V 8Ah Batteries Required. *Magnetic Door Holders are not included in the battery calculations. Power to these devices will be automatically disconnected upon loss of NC power to reduce battery size. DEVICE LEGEND Devices Current (Milliamps) Designator Part Number Description Light Ouput 0 15cd 30cd 75cd 95cd 110cd 177cd A B C D E F G H I J K L M N 0 P Q R S T U V W X Y SB4U SB4U-LF GSA-SBT SIGA-AB4G-LF INT-7ATW INT-8ATW EG1F-HD EG1F-VM EG1F-HDVM EGCF-VM EGCF-VMH EGCF-HDVM EGCF-HDVMH G4LFWF-H G4LFWF-HVM G4HFWF-S7VMC GCHFWF-S7VMC INT-4ASW XXXX DHF -24120C C01224T XXXX XXXX XXXX XXXX Sounder Base for V Series Detectors 520Hz Sounder Base for V Series Detectors Sounder Base for PCOS Detectors 520Hz Sounder Base for PCOS Detectors WP Wall Mount Horn/Strobe WP Wall Mount Horn/Strobe Wall Mount Horn Wall Mount Strobe Wall Mount Horn/Strobe Ceiling Mount Strobe Ceiling Mount High Candela Strobe Ceiling Mount Horn/Strobe Ceiling Mount High Candela Horn/Strobe Wall Mount 520Hz Horn Wall Mount 520Hz Horn/Strobe Wall Mount Speaker/Strobe Ceiling Mount Speaker/Strobe Weatherproof Speaker/Strobe )(XXX Magnetic Door Hold -Open Carbon Monoxide Detector XXXX XXXX XXXX XXXX 28 92 52 92 180 90 22 85 127 245 285 102 135 160 246 309 94 140 273 325 333 551 111 152 281 333 324 554 166 219 266 381 437 78 101 188 245 94 140 273 325 551 159 15 75 Z N/A END OF CIRCUIT Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP6 Circuit: NAC1 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0.491 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms / 1000' 8 14 3.07 210 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 6.1.1 P 15 0.078 8 20.376 0.024 0.0012 6.1.2 P 30 0.101 28 20.305 0.095 0.0047 6.1.3 P 15 0.078 29 20.249 0.151 0.0074 6.1.4 P 15 0.078 52 20.175 0.225 0.0110 6.1.5 P 15 0.078 50 20.127 0.273 0.0134 6.1.6 P 15 0.078 51 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 Totals: 0.491 218 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 1.46% Current: 0.491 Distance: 218 End Line Voltage: Voltage Drop: 0.30 of 20.10 CIRCUIT IS WITHIN LIMITS Percent Drop: 1.61% Load Centering Method Current: 0.491 Distance: Voltage Drop: 218 End of Line Voltage: 20.07 0.33 End of Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 3.22% Current: I 0.491 Distance: 218 Voltage Drop: End of Line Voltage: 19.74 0.66 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP6 Circuit: NAC2 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 2.13 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guage Ohms/ 1000' 31 14 3.07 123 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 6.2.1 P 110 0.245 31 19.995 0.405 0.0199 6.2.2 P 110 0.245 9 19.890 0.510 0.0250 6.2.3 H 15 0.085 19 19.699 0.701 0.0344 6.2.4 P 110 0.245 8 19.623 0.777 0.0381 6.2.5 P 110 0.245 7 19.566 0.834 0.0409 6.2.6 P 110 0.245 9 19.508 0.892 0.0437 6.2.7 H 15 0.085 12 19.447 0.953 0.0467 6.2.8 P 110 0.245 43 19.253 1.147 0.0562 6.2.9 P 110 0.245 9 19.226 1.174 0.0575 6.2.10 P 110 0.245 7 19.215 1.185 0.0581 END Z 0.000 0 19.215 1.185 0.0581 END Z 0.000 0 19.215 1.185 0.0581 END Z 0.000 0 19.215 1.185 0.0581 END Z 0.000 0 19.215 1.185 0.0581 END Z 0.000 0 19.215 1.185 0.0581 END Z 0.000 0 19.215 1.185 0.0581 END Z 0.000 0 19.215 1.185 0.0581 END Z 0.000 0 19.215 1.185 0.0581 END Z 0.000 0 19.215 1.185 0.0581 END Z 0.000 0 19.215 1.185 0.0581 END Z 0.000 0 19.215 1.185 0.0581 T+ I40 : Q42 ota l s : 2.13 154 CIRCUIT IS WITHIN LIMITS Percent Drop: 5.81% Current: 2.13 Point to Point Method 154 19.22 Distance: Voltage Drop: End of Line Voltage: 1.18 CIRCUIT IS WITHIN LIMITS Percent Drop: 4.94% Load Centering Method Current: 2.13 154 19.39 Distance: Voltage Drop: End of Line Voltage: 1.01 CIRCUIT IS WITHIN LIMITS Percent Drop: 9.87% Current: 2.13 End of Line Method 154 18.39 Distance: Voltage Drop: End of Line Voltage: 2.01 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP6 Circuit: NAC3 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guaae Ohms/ 1000' 0 14 3.07 0 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 Totals: 0 0 Point to Point Method CIRCUIT IS WITHIN LIMITS' Percent Drop: 0.00% Current: 0 0 Distance: End Line Voltage: Voltage Drop: 0.00 of 20.40 CIRCUIT IS WITHIN LIMITS Load Centering Method Percent Drop: 0.00% Current: 0 0 20.40 Distance: Voltage Drop: End of Line Voltage: 0.00 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 End of Line Method 0 20.40 Distance: Voltage Drop: End of Line Voltage: 0.00 PrOlect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP6 Circuit: NAC4 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.288 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guage Ohms/ 1000' 28 14 3.07 326 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 6.4.1 D 0.092 28 20.179 0.221 0.0109 6.4.2 D 0.092 21 20.024 0.376 0.0184 6.4.3 D 0.092 16 19.916 0.484 0.0237 6.4.4 D 0.092 21 19.785 0.615 0.0301 6.4.5 D 0.092 24 19.650 0.750 0.0368 6.4.6 D 0.092 19 19.553 0.847 0.0415 6.4.7 D 0.092 23 19.449 0.951 0.0466 6.4.8 D 0.092 81 19.129 1.271 0.0623 6.4.9 D 0.092 20 19.061 1.339 0.0656 6.4.10 D 0.092 25 18.991 1.409 0.0691 6.4.11 D 0.092 21 18.943 1.457 0.0714 6.4.12 D 0.092 12 18.923 1.477 0.0724 6.4.13 D 0.092 21 18.899 1.501 0.0736 6.4.14 D 0.092 22 18.887 1.513 0.0742 END Z 0.000 0 18.887 1.513 0.0742 END Z 0.000 0 18.887 1.513 0.0742 END Z 0.000 0 18.887 1.513 0.0742 END Z 0.000 0 18.887 1.513 0.0742 END Z 0.000 0 18.887 1.513 0.0742 END Z 0.000 0 18.887 1.513 0.0742 END Z 0.000 0 18.887 1.513 0.0742 Totals: 1.288 354 CIRCUIT IS WITHIN LIMITS Percent Drop: 7.42% Current: 1.288 Point to Point Method 354 18.89 Distance: Voltage Drop: End of Line Voltage: 1.51 CIRCUIT IS WITHIN LIMITS Percent Drop: 6.86% Current: 1.288 Load Centering Method 354 19.00 Distance: Voltage Drop: End of Line Voltage: 1.40 CIRCUIT IS WITHIN LIMITS Percent Drop: 13.72% Current: 1.288 End of Line Method 354 17.60 Distance: Voltage Drop: End of Line Voltage: 2.80 Prosect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP6 Battery Calculations Standy Circuit / Device Current Alarm Current Qty Total Standy Current Total Alarm Current Power Supply 70 70 1 70 70 NAC Power NAC1 0 491 1 0 491 NAC2 0 2130 1 0 2130 NAC3 0 0 0 0 0 NAC4 84 1288 1 84 0 200 mA Aux Power Aux 0 0 0 0 0 Aux 0 0 0 0 0 Aux 0 0 0 0 0 TOTALS: 154 2691 Total Standy Current (Amps): 0.154 X 24 Hours: 3.696 Amphours in Standy Total Alarm Current (Amps): 2.691 X 15 Mins: 0.67 Amphours in Alarm 4.37 Required Amphours Required Amphours: +20% Safety 4.37 5'24 Total Margin Am hours p (2) 12V 8Ah Batteries Required. *Magnetic Door Holders are not included in the battery calculations. Power to these devices will be automatically disconnected upon Toss of NC power to reduce battery size. DEVICE LEGEND Devices Current (Milliamps) Designator Part Number Description Light Ouput 0 15cd 30cd 75cd 95cd 110cd 177cd A B C D E F G H I J K L M N O P Q R S T U V W X Y SB4U SB4U-LF GSA-SBT SIGA-AB4G-LF INT-7ATW INT-8ATW EG1F-HD EG1F-VM EG1F-HDVM EGCF-VM EGCF-VMH EGCF-HDVM EGCF-HDVMH G4LFWF-H G4LFWF-HVM G4HFWF-S7VMC GCHFWF-S7VMC INT-4ASW XXXX DHF -24120C C01224T XXXX XXXX XXXX XXXX Sounder Base for V Series Detectors 520Hz Sounder Base for V Series Detectors Sounder Base for PCOS Detectors 520Hz Sounder Base for PCOS Detectors WP Wall Mount Horn/Strobe WP Wall Mount Horn/Strobe Wall Mount Horn Wall Mount Strobe Wall Mount Horn/Strobe Ceiling Mount Strobe Ceiling Mount High Candela Strobe Ceiling Mount Horn/Strobe Ceiling Mount High Candela Horn/Strobe Wall Mount 520Hz Horn Wall Mount 520Hz Horn/Strobe Wall Mount Speaker/Strobe Ceiling Mount Speaker/Strobe Weatherproof Speaker/Strobe XXXX Magnetic Door Hold -Open Carbon Monoxide Detector XXXX )(XXX XXXX XXXX 28 92 52 92 180 90 22 85 127 135 245 160 285 102 246 309 94 140 273 325 333 551 111 152 281 333 324 554 166 219 266 381 437 78 101 188 245 94 140 273 325 551 159 15 75 Z N/A END OF CIRCUIT Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP7 Circuit: NAC1 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.225 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 136 14 3.07 81 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 7.1.1 P 110 0.245 136 19.377 1.023 0.0501 7.1.2 P 110 0.245 22 19.245 1.155 0.0566 7.1.3 P 110 0.245 19 19.159 1.241 0.0608 7.1.4 P 110 0.245 22 19.093 1.307 0.0641 7.1.5 P 110 0.245 18 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 Totals: 1.225 217 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 6.54% Current: 1.225 Distance: 217 End Line Voltage: Voltage Drop: 1.33 of 19.07 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 4.00% Current: 1.225 217 19.58 Distance: Voltage Drop: End of Line Voltage: 0.82 End of Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 8.00% Current: 1.225 217 18.77 Distance: Voltage Drop: End of Line Voltage: 1.63 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP7 Circuit: NAC2 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.225 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 56 14 3.07 101 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 7.2.1 P 110 0.245 56 19.979 0.421 0.0206 7.2.2 P 110 0.245 32 19.786 0.614 0.0301 7.2.3 P 110 0.245 9 19.746 0.654 0.0321 7.2.4 P 110 0.245 35 19.640 0.760 0.0372 7.2.5 P 110 0.245 25 19.603 0.797 0.0391 END Z 0.000 0 19.603 0.797 0.0391 END Z 0.000 0 19.603 0.797 0.0391 END Z 0.000 0 19.603 0.797 0.0391 END Z 0.000 0 19.603 0.797 0.0391 END Z 0.000 0 19.603 0.797 0.0391 END Z 0.000 0 19.603 0.797 0.0391 END Z 0.000 0 19.603 0.797 0.0391 END Z 0.000 0 19.603 0.797 0.0391 END Z 0.000 0 19.603 0.797 0.0391 END Z 0.000 0 19.603 0.797 0.0391 END Z 0.000 0 19.603 0.797 0.0391 END Z 0.000 0 19.603 0.797 0.0391 END Z 0.000 0 19.603 0.797 0.0391 END Z 0.000 0 19.603 0.797 0.0391 END Z 0.000 0 19.603 0.797 0.0391 END Z 0.000 0 19.603 0.797 0.0391 T+I40:Q42otals: 1.225 157 CIRCUIT IS WITHIN LIMITS Percent Drop: 3.91% Point to Point Method Current: 1.225 157 19.60 Distance: Voltage Drop: End of Line Voltage: 0.80 CIRCUIT IS WITHIN LIMITS Percent Drop: 2.89% Load Centering Method Current: 1.225 157 19.81 Distance: Voltage Drop: End of Line Voltage: 0.59 CIRCUIT IS WITHIN LIMITS Percent Drop: 5.79% Current: 1.225 End of Line Method 157 19.22 Distance: Voltage Drop: End of Line Voltage: 1.18 Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP7 Circuit: NAC3 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0.491 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guaae Ohms/ 1000' 6 14 3.07 205 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 7.3.1 P 30 0.101 6 20.382 0.018 0.0009 7.3.2 P 15 0.078 16 20.344 0.056 0.0028 7.3.3 P 15 0.078 52 20.244 0.156 0.0076 7.3.4 P 15 0.078 53 20.168 0.232 0.0114 7.3.5 P 15 0.078 54 20.116 0.284 0.0139 7.3.6 P 15 0.078 30 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 Totals: 0.491 211 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent 1.46% Current: Drop: 0.491 Distance: 211 End Line Voltage: Voltage Drop: 20.10 of 0.30 Load Centering Method CIRCUIT IS WITHIN LIMITS 1.56% Current: Percent Drop: 0.491 211 End Line Voltage: 20.08 Distance: Voltage Drop: of 0.32 End Line Method CIRCUIT IS WITHIN LIMITS Percent 3.12% Current: Drop: 0.491 of Distance: 211 End Line Voltage Drop: of Voltage: 0.64 19.76 Proiect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP7 Circuit: NAC4 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guaae Ohms/ 1000' 0 14 3.07 0 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 Totals: 0 0 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 Point to Point Method 0 20.40 Distance: Voltage Drop: End of Line Voltage: 0.00 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 Distance: 0 Voltage Drop: End of Line Voltage: 20.40 0.00 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 End of Line Method 0 20.40 Distance: Voltage Drop: End of Line Voltage: 0.00 Prosect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP7 Battery Calculations Circuit / Device Standy Current Alarm Current Qty Total Standy Current Total Alarm Current Power Supply 70 70 1 70 70 NAC Power NAC1 0 1225 1 0 1225 NAC2 0 1225 1 0 1225 NAC3 0 491 1 0 491 NAC4 0 0 0 0 0 200 mA Aux Power Aux 0 0 0 0 0 Aux 0 0 0 0 0 Aux 0 0 0 0 0 TOTALS: 70 3011 Total Standy Current (Amps): 0.07 X 24 Hours: 1.68 Amphours in Standy Total Alarm Current (Amps): 3.011 X 15 Mins: 0.75 Amphours in Alarm 2.43 Required Amphours +20% Safety Total Required Amphours: 2.43 Margin 2.92 hours Amphours (2) 12V 3Ah Batteries Required. "Magnetic Door Holders are not included in the battery calculations. Power to these devices will be automatically disconnected upon loss of A/C power to reduce battery size. DEVICE LEGEND Devices Current (Milliamps) Designator Part Number Description Light Ouput 0 15cd 30cd 75cd 95cd 110cd 177cd A B C D E F G H I J K L M N 0 P Q R S T U V W X Y SB4U SB4U-LF GSA-SBT SIGA-AB4G-LF INT-7ATW INT-8ATW EG1F-HD EG1F-VM EG1F-HDVM EGCF-VM EGCF-VMH EGCF-HDVM EGCF-HDVMH G4LFWF-H G4LFWF-HVM G4HFWF-S7VMC GCHFWF-S7VMC INT-4ASW XXXX DHF-24120C C01224T XXXX XXXX XXXX XXXX Sounder Base for V Series Detectors 520Hz Sounder Base for V Series Detectors Sounder Base for PCOS Detectors 520Hz Sounder Base for PCOS Detectors WP Wall Mount Horn/Strobe WP Wall Mount Horn/Strobe Wall Mount Horn Wall Mount Strobe Wall Mount Horn/Strobe Ceiling Mount Strobe Ceiling Mount High Candela Strobe Ceiling Mount Horn/Strobe Ceiling Mount High Candela Horn/Strobe Wall Mount 520Hz Horn Wall Mount 520Hz Horn/Strobe Wall Mount Speaker/Strobe Ceiling Mount Speaker/Strobe Weatherproof Speaker/Strobe XXXX Magnetic Door Hold-Open Carbon Monoxide Detector )(XXX XXXX XXXX XXXX 28 92 52 92 180 90 22 85 127 135 245 160 246 285 102 309 94 140 273 325 333 551 111 152 281 333 324 554 166 219 266 381 437 78 101 188 245 94 140 273 325 551 159 15 75 Z N/A END OF CIRCUIT Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP8 Circuit: NAC1 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.47 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 103 14 3.07 128 14 3.07 I Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 8.1.1 P 110 0.245 103 19.470 0.930 0.0456 8.1.2 P 110 0.245 26 19.275 1.125 0.0552 8.1.3 P 110 0.245 21 19.148 1.252 0.0614 8.1.4 P 110 0.245 37 18.981 1.419 0.0695 8.1.5 P 110 0.245 21 18.918 1.482 0.0726 8.1.6 P 110 0.245 23 18.884 1.516 0.0743 END Z 0.000 0 18.884 1.516 0.0743 END Z 0.000 0 18.884 1.516 0.0743 END Z 0.000 0 18.884 1.516 0.0743 END Z 0.000 0 18.884 1.516 0.0743 END Z 0.000 0 18.884 1.516 0.0743 END Z 0.000 0 18.884 1.516 0.0743 END Z 0.000 0 18.884 1.516 0.0743 END Z 0.000 0 18.884 1.516 0.0743 END Z 0.000 0 18.884 1.516 0.0743 END Z 0.000 0 18.884 1.516 0.0743 END Z 0.000 0 18.884 1.516 0.0743 END Z 0.000 0 18.884 1.516 0.0743 END Z 0.000 0 18.884 1.516 0.0743 END Z 0.000 0 18.884 1.516 0.0743 END Z 0.000 0 18.884 1.516 0.0743 Totals: 1.47 231 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 7.43% Current: 1.47 Distance: 231 End Line Voltage Drop: 1.52 of Voltage: 18.88 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 5.11% Current: 1.47 Distance: 231 Voltage Drop: End of Line Voltage: 19.36 1.04 End Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 10.22% Current:' 1.47 of Distance: 231 End Line Voltage: 18.32 Voltage Drop: 2.08 of Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP8 Circuit: NAC2 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.31 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 12 14 3.07 106 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 8.2.1 P 110 0.245 12 20.303 0.097 0.0047 8.2.2 P 110 0.245 26 20.133 0.267 0.0131 8.2.3 P 110 0.245 22 20.023 0.377 0.0185 8.2.4 P 110 0.245 9 19.991 0.409 0.0201 8.2.5 P 110 0.245 41 19.908 0.492 0.0241 8.2.6 H 15 0.085 8 19.904 0.496 0.0243 END Z 0.000 0 19.904 0.496 0.0243 END Z 0.000 0 19.904 0.496 0.0243 END Z 0.000 0 19.904 0.496 0.0243 END Z 0.000 0 19.904 0.496 0.0243 END Z 0.000 0 19.904 0.496 0.0243 END Z 0.000 0 19.904 0.496 0.0243 END Z 0.000 0 19.904 0.496 0.0243 END Z 0.000 0 19.904 0.496 0.0243 END Z 0.000 0 19.904 0.496 0.0243 END Z 0.000 0 19.904 0.496 0.0243 END Z 0.000 0 19.904 0.496 0.0243 END Z 0.000 0 19.904 0.496 0.0243 END Z 0.000 0 19.904 0.496 0.0243 END Z 0.000 0 19.904 0.496 0.0243 END Z 0.000 0 19.904 0.496 0.0243 T+140:Q42otals: 1.31 118 CIRCUIT IS WITHIN LIMITS Percent Drop: 2.43% Point to Point Method Current: 1.31 118 19.90 Distance: Voltage Drop: End of Line Voltage: 0.50 CIRCUIT IS WITHIN LIMITS Percent Drop: 2.33% Load Centering Method Current: 1.31 118 19.93 Distance: Voltage Drop: End of Line Voltage: 0.47 CIRCUIT IS WITHIN LIMITS Percent Drop: 4.65% End of Line Method Current: 1.31 118 19.45 Distance: Voltage Drop: End of Line Voltage: 0.95 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP8 Circuit: NAC3 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.225 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guaae Ohms/ 1000' 152 14 3.07 76 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 8.3.1 P 110 0.245 152 19.257 1.143 0.0560 8.3.2 P 110 0.245 19 19.142 1.258 0.0616 8.3.3 P 110 0.245 9 19.102 1.298 0.0636 8.3.4 P 110 0.245 39 18.984 1.416 0.0694 8.3.5 P 110 0.245 9 18.971 1.429 0.0701 END Z 0.000 0 18.971 1.429 0.0701 END Z 0.000 0 18.971 1.429 0.0701 END Z 0.000 0 18.971 1.429 0.0701 END Z 0.000 0 18.971 1.429 0.0701 END Z 0.000 0 18.971 1.429 0.0701 END Z 0.000 0 18.971 1.429 0.0701 END Z 0.000 0 18.971 1.429 0.0701 END Z 0.000 0 18.971 1.429 0.0701 END Z 0.000 0 18.971 1.429 0.0701 END Z 0.000 0 18.971 1.429 0.0701 END Z 0.000 0 18.971 1.429 0.0701 END Z 0.000 0 18.971 1.429 0.0701 END Z 0.000 0 18.971 1.429 0.0701 END Z 0.000 0 18.971 1.429 0.0701 END Z 0.000 0 18.971 1.429 0.0701 END Z 0.000 0 18.971 1.429 0.0701 Totals: 1.225 228 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 7.01% Current: 1.225 Distance: 228 End Line Voltage: Voltage Drop: 1.43 of 18.97 CIRCUIT IS WITHIN LIMITS Percent Drop: 4.20% Load Centering Method Current: 1.225 228 19.54 Distance: Voltage Drop: End of Line Voltage: 0.86 CIRCUIT IS WITHIN LIMITS Percent Drop: 8.41% End of Line Method Current: 1.225 228 18.69 Distance: Voltage Drop: End of Line Voltage: 1.71 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP8 Circuit: NAC4 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.012 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guaae Ohms/ 1000' 16 14 3.07 241 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 8.4.1 D 0.092 16 20.301 0.099 0.0049 8.4.2 D 0.092 18 20.199 0.201 0.0099 8.4.3 D 0.092 31 20.041 0.359 0.0176 8.4.4 D 0.092 15 19.974 0.426 0.0209 8.4.5 D 0.092 23 19.883 0.517 0.0254 8.4.6 D 0.092 28 19.788 0.612 0.0300 8.4.7 D 0.092 18 19.737 0.663 0.0325 8.4.8 D 0.092 27 19.676 0.724 0.0355 8.4.9 D 0.092 28 19.628 0.772 0.0378 8.4.10 D 0.092 24 19.601 0.799 0.0392 8.4.11 D 0.092 29 19.585 0.815 0.0400 END Z 0.000 0 19.585 0.815 0.0400 END Z 0.000 0 19.585 0.815 0.0400 END Z 0.000 0 19.585 0.815 0.0400 END Z 0.000 0 19.585 0.815 0.0400 END Z 0.000 0 19.585 0.815 0.0400 END Z 0.000 0 19.585 0.815 0.0400 END Z 0.000 0 19.585 0.815 0.0400 END Z 0.000 0 19.585 0.815 0.0400 END Z 0.000 0 19.585 0.815 0.0400 END Z 0.000 0 19.585 0.815 0.0400 Totals: 1.012 257 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 4.00% Current: 1.012 Distance: 257 Voltage Drop: End of Line Voltage: 19.58 0.82 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 3.91% Current: 1.012 Distance: 257 Voltage Drop: End of Line Voltage: 19.60 0.80 End Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 7.83% Current: 1.012 of Distance: 257 Voltage Drop: End of Line Voltage: 18.80 1.60 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP8 Battery Calculations Standy Circuit / Device Current Alarm Current Qty Total Standy Current Total Alarm Current Power Supply 70 70 1 70 70 NAC Power NAC1 0 1470 1 0 1470 NAC2 0 1310 1 0 1310 NAC3 0 1225 1 0 1225 NAC4 66 1012 1 66 0 200 mA Aux Power Aux 0 0 0 0 0 Aux 0 0 0 0 0 Aux 0 0 0 0 0 TOTALS: 136 4075 Total Standy Current (Amps): 0.136 X 24 Hours: 3.264 Amphours in Standy Total Alarm Current (Amps): 4.075 X 15 Mins: 1.02 Amphours in Alarm 4.28 Required Amphours Required Amphours: +20% Safety 4.28 5'14 Total Margin Am hours p (2) 12V 8Ah Batteries Required. *Magnetic Door Holders are not included in the battery calculations. Power to these devices will be automatically disconnected upon Toss of A/C power to reduce battery size. DEVICE LEGEND Devices Current (Milliamps) Designator Part Number Description LightOuput 0 15cd 30cd 75cd 95cd 110cd 177cd A B C D E F G H I J K L M N 0 P Q R S T U V W X Y SB4U SB4U-LF GSA-SBT SIGA-AB4G-LF INT-7ATW INT-8ATW EG1F-HD EG1 F -VM EG1F-HDVM EGCF-VM EGCF-VMH EGCF-HDVM EGCF-HDVMH G4LFWF-H G4LFWF-HVM G4HFWF-S7VMC GCHFWF-S7VMC INT-4ASW XXXX DHF -24120C C01224T XXXX )(XXX XXXX XXXX Sounder Base for V Series Detectors 520Hz Sounder Base for V Series Detectors Sounder Base for PCOS Detectors 520Hz Sounder Base for PCOS Detectors WP Wall Mount Horn/Strobe WP Wall Mount Horn/Strobe Wall Mount Horn Wall Mount Strobe Wall Mount Horn/Strobe Ceiling Mount Strobe Ceiling Mount High Candela Strobe Ceiling Mount Horn/Strobe Ceiling Mount High Candela Horn/Strobe Wall Mount 520Hz Horn Wall Mount 520Hz Horn/Strobe Wall Mount Speaker/Strobe Ceiling Mount Speaker/Strobe Weatherproof Speaker/Strobe )(XXX Magnetic Door Hold -Open Carbon Monoxide Detector )(XXX XXXX XXXX XXXX 28 92 52 92 180 90 22 8.5 102 127 135 _ 245 160 _ 246 _ 285 309 94 140 273 325 333 551 111 152 281 333 324 554 166 219 266 381 437 78 101 188 245 94 140 273 325 551 159 15 75 Z N/A END OF CIRCUIT PrOiect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP9 Circuit: NAC1 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.47 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 36 14 3.07 104 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 9.1.1 P 110 0.245 36 20.075 0.325 0.0159 9.1.2 P 110 0.245 20 19.925 0.475 0.0233 9.1.3 P 110 0.245 22 19.792 0.608 0.0298 9.1.4 P 110 0.245 20 19.702 0.698 0.0342 9.1.5 P 110 0.245 23 19.633 0.767 0.0376 9.1.6 P 110 0.245 19 19.604 0.796 0.0390 END Z 0.000 0 19.604 0.796 0.0390 END Z 0.000 0 19.604 0.796 0.0390 END Z 0.000 0 19.604 0.796 0.0390 END Z 0.000 0 19.604 0.796 0.0390 END Z 0.000 0 19.604 0.796 0.0390 END Z 0.000 0 19.604 0.796 0.0390 END Z 0.000 0 19.604 0.796 0.0390 END Z 0.000 0 19.604 0.796 0.0390 END Z 0.000 0 19.604 0.796 0.0390 END Z 0.000 0 19.604 0.796 0.0390 END Z 0.000 0 19.604 0.796 0.0390 END Z 0.000 0 19.604 0.796 0.0390 END Z 0.000 0 19.604 0.796 0.0390 END Z 0.000 0 19.604 0.796 0.0390 END Z 0.000 0 19.604 0.796 0.0390 Totals: 1.47 140 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 3.90% Current: 1.47 Distance: 140 End Line Voltage: Voltage Drop: 0.80 of 19.60 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 3.10% Current: 1, 1.47 � 140 19.77 Distance: Voltage Drop:1 End of Line Voltage: 0.63 CIRCUIT IS WITHIN LIMITS Percent Drop: 6.19% End of Line Method Current: 1.47 140 19.14 Distance: Voltage Drop:, End of Line Voltage: 1.26 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP9 Circuit: NAC2 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.715 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guage Ohms/ 1000' 167 14 3.07 95 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 9.2.1 P 110 0.245 167 18.641 1.759 0.0862 9.2.2 P 110 0.245 19 18.470 1.930 0.0946 9.2.3 P 110 0.245 18 18.335 2.065 0.1012 9.2.4 P 110 0.245 9 18.280 2.120 0.1039 9.2.5 P 110 0.245 33 18.132 2.268 0.1112 9.2.6 P 110 0.245 9 18.104 2.296 0.1125 9.2.7 P 110 0.245 7 18.094 2.306 0.1130 END Z 0.000 0 18.094 2.306 0.1130 END Z 0.000 0 18.094 2.306 0.1130 END Z 0.000 0 18.094 2.306 0.1130 END Z 0.000 0 18.094 2.306 0.1130 END Z 0.000 0 18.094 2.306 0.1130 END Z 0.000 0 18.094 2.306 0.1130 END Z 0.000 0 18.094 2.306 0.1130 END Z 0.000 0 18.094 2.306 0.1130 END Z 0.000 0 18.094 2.306 0.1130 END Z 0.000 0 18.094 2.306 0.1130 END Z 0.000 0 18.094 2.306 0.1130 END Z 0.000 0 18.094 2.306 0.1130 END Z 0.000 0 18.094 2.306 0.1130 END Z 0.000 0 18.094 2.306 0.1130 T+I40:Q42otals: 1.715 262 CIRCUIT IS WITHIN LIMITS Percent Drop: 11.30% Current: 1.715 Point to Point Method 262 18.09 Distance: Voltage Drop: End of Line Voltage: 2.31 CIRCUIT IS WITHIN LIMITS Percent Drop: 6.76% Load Centering Method Current: 1.715 262 19.02 Distance: Voltage Drop: End of Line Voltage: 1.38 CIRCUIT IS WITHIN LIMITS End of Line Method Percent Drop: 13.52% Current: 1.715 262 17.64 Distance: Voltage Drop: End of Line Voltage: 2.76 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP9 Circuit: NAC3 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.225 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guaae Ohms/ 1000' 135 14 3.07 84 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 9.3.1 P 110 0.245 135 19.385 1.015 0.0498 9.3.2 P 110 0.245 23 19.246 1.154 0.0566 9.3.3 P 110 0.245 20 19.156 1.244 0.0610 9.3.4 P 110 0.245 19 19.099 1.301 0.0638 9.3.5 P 110 0.245 22 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 Totals: 1.225 219 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 6.54% Current: 1.225 Distance: 219 End Line Voltage: Voltage Drop: 1.33 of 19.07 CIRCUIT IS WITHIN LIMITS Percent Drop: 4.04% Load Centering Method Current: 1.225 219 19.58 Distance: Voltage Drop: End of Line Voltage: 0.82 CIRCUIT IS WITHIN LIMITS Percent Drop: 8.07% End of Line Method Current: 1.225 219 18.75 Distance: Voltage Drop: End of Line Voltage: 1.65 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP9 Circuit: NAC4 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.012 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guaae Ohms/ 1000' 34 14 3.07 206 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 9.4.1 D 0.092 34 20.189 0.211 0.0104 9.4.2 D 0.092 20 20.076 0.324 0.0159 9.4.3 D 0.092 21 19.969 0.431 0.0211 9.4.4 D 0.092 20 19.879 0.521 0.0256 9.4.5 D 0.092 23 19.788 0.612 0.0300 9.4.6 D 0.092 19 19.723 0.677 0.0332 9.4.7 D 0.092 19 19.670 0.730 0.0358 9.4.8 D 0.092 22 19.620 0.780 0.0382 9.4.9 D 0.092 19 19.588 0.812 0.0398 9.4.10 D 0.092 25 19.559 0.841 0.0412 9.4.11 D 0.092 18 19.549 0.851 0.0417 END Z 0.000 0 19.549 0.851 0.0417 END Z 0.000 0 19.549 0.851 0.0417 END Z 0.000 0 19.549 0.851 0.0417 END Z 0.000 0 19.549 0.851 0.0417 END Z 0.000 0 19.549 0.851 0.0417 END Z 0.000 0 19.549 0.851 0.0417 END Z 0.000 0 19.549 0.851 0.0417 END Z 0.000 0 19.549 0.851 0.0417 END Z 0.000 0 19.549 0.851 0.0417 END Z 0.000 0 19.549 0.851 0.0417 Totals: 1.012 240 CIRCUIT IS WITHIN LIMITS Percent Drop: 4.17% Current: 1.012 Point to Point Method 240 19.55 Distance: End of Line Voltage: 0.85 Voltage Drop: CIRCUIT IS WITHIN LIMITS Percent Drop: 3.66% Current: 1.012 Load Centering Method 240 19.65 Distance: End of Line Voltage: 0.75 Voltage Drop: CIRCUIT IS WITHIN LIMITS Percent Drop: 7.31% Current: 1.012 End of Line Method 240 18.91 Distance: End of Line Voltage: 1.49 Voltage Drop: Plroiect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP9 Battery Calculations Standy Circuit / Device Current Alarm Current Qty Total Standy Current Total Alarm Current Power Supply 70 70 1 70 70 NAC Power NAC1 0 1470 1 0 1470 NAC2 0 1715 1 0 1715 NAC3 0 1225 1 0 1225 NAC4 66 1012 1 66 0 200 mA Aux Power Aux 0 0 0 0 0 Aux 0 0 0 0 0 Aux 0 0 0 0 0 TOTALS: 136 4480 Total Standy Current (Amps): 0.136 X 24 Hours: 3.264 Amphours in Standy Total Alarm Current (Amps): 4.48 X 15 Mins: 1.12 Amphours in Alarm 4.38 Required Amphours Required Amphours: +20% Safety 4.38 5.26 Total Margin Am hours p (2) 12V 8Ah Batteries Required. *Magnetic Door Holders are not included in the battery calculations. Power to these devices will be automatically disconnected upon Toss of NC power to reduce battery size. DEVICE LEGEND Devices Current (Milliamps) Designator Part Number Description Light Ouput 0 15cd 30cd 75cd 95cd 110cd 177cd A B C D E F G H I J K L M N 0 P Q R S T U V W X Y SB4U SB4U-LF GSA-SBT SIGA-AB4G-LF INT-7ATW INT-8ATW EG1F-HD EG1F-VM EG1F-HDVM EGCF-VM EGCF-VMH EGCF-HDVM EGCF-HDVMH G4LFWF-H G4LFWF-HVM G4HFWF-S7VMC GCHFWF-S7VMC INT-4ASW XXXX DHF-24120C CO1224T XXXX )(XXX XXXX XXXX Sounder Base for V Series Detectors 520Hz Sounder Base for V Series Detectors Sounder Base for PCOS Detectors 520Hz Sounder Base for PCOS Detectors WP Wall Mount Horn/Strobe WP Wall Mount Horn/Strobe Wall Mount Horn Wall Mount Strobe Wall Mount Horn/Strobe Ceiling Mount Strobe Ceiling Mount High Candela Strobe Ceiling Mount Horn/Strobe Ceiling Mount High Candela Horn/Strobe Wall Mount 520Hz Horn Wall Mount 520Hz Horn/Strobe Wall Mount Speaker/Strobe Ceiling Mount Speaker/Strobe Weatherproof Speaker/Strobe )(XXX Magnetic Door Hold-Open Carbon Monoxide Detector X00( XXXX XXXX X00( 28 92 52 92 180 90 22 85 127 245 285 102 135 160 246 309 94 140 273 325 333 551 111 152 281 333 324 554 166 219 266 381 437 78 101 188 245 94 140 273 325 551 159 15 75 Z N/A END OF CIRCUIT Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP10 Circuit: NAC1 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0.491 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 36 14 3.07 207 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 10.1.1 P 15 0.078 36 20.291 0.109 0.0053 10.1.2 P 30 0.101 25 20.228 0.172 0.0084 10.1.3 P 15 0.078 30 20.171 0.229 0.0112 10.1.4 P 15 0.078 52 20.096 0.304 0.0149 10.1.5 P 15 0.078 50 20.048 0.352 0.0173 10.1.6 P 15 0.078 50 20.024 0.376 0,0184 END Z 0.000 0 20.024 0.376 0.0184 END Z 0.000 0 20.024 0.376 0.0184 END Z 0.000 0 20.024 0.376 0.0184 END Z 0.000 0 20.024 0.376 0.0184 END Z 0.000 0 20.024 0.376 0.0184 END Z 0.000 0 20.024 0.376 0.0184 END Z 0.000 0 20.024 0.376 0.0184 END Z 0.000 0 20.024 0.376 0.0184 END Z 0.000 0 20.024 0.376 0.0184 END Z 0.000 0 20.024 0.376 0.0184 END Z 0.000 0 20.024 0.376 0.0184 END Z 0.000 0 20.024 0.376 0.0184 END Z 0.000 0 20.024 0.376 0.0184 END Z 0.000 0 20.024 0.376 0.0184 END Z 0.000 0 20.024 0.376 0.0184 Totals: 0.491 243 CIRCUIT IS WITHIN LIMITS Percent Drop: 1.84% Current: 0.491 Point to Point Method Distance: End Line Voltage: 243 Voltage Drop:; 0.38 of 20.02 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 1.80% Current: 0.491 243 20.03 Distance: End Line Voltage: Voltage Drop: 0.37 of End of Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 3.59% Current: 0.491 243 Distance: Voltage Drop: End of Line Voltage: 19.67 0.73 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP10 Circuit: NAC2 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.8 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 37 14 3.07 124 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 10.2.1 P 110 0.245 37 19.991 0.409 0.0200 10.2.2 P 110 0.245 9 19.905 0.495 0.0243 10.2.3 P 110 0.245 23 19.720 0.680 0.0333 10.2.4 P 110 0.245 20 19.589 0.811 0.0397 10.2.5 P 110 0.245 22 19.479 0.921 0.0452 10.2.6 P 110 0.245 23 19.397 1.003 0.0491 10.2.7 H 15 0.085 7 19.383 1.017 0.0498 10.2.8 P 110 0.245 20 19.353 1.047 0.0513 END Z 0.000 0 19.353 1.047 0.0513 END Z 0.000 0 19.353 1.047 0.0513 END Z 0.000 0 19.353 1.047 0.0513 END Z 0.000 0 19.353 1.047 0.0513 END Z 0.000 0 19.353 1.047 0.0513 END Z 0.000 0 19.353 1.047 0.0513 END Z 0.000 0 19.353 1.047 0.0513 END Z 0.000 0 19.353 1.047 0.0513 END Z 0.000 0 19.353 1.047 0.0513 END Z 0.000 0 19.353 1.047 0.0513 END Z 0.000 0 19.353 1.047 0.0513 END Z 0.000 0 19.353 1.047 0.0513 END Z 0.000 0 19.353 1.047 0.0513 T+140: Q42otals: 1.8 161 CIRCUIT IS WITHIN LIMITS Point to Point Method Percent Drop: 5.13% Current: 1.8 161 19.35 Distance: Voltage Drop: End of Line Voltage: 1.05 CIRCUIT IS WITHIN LIMITS Percent Drop: 4.36% Load Centering Method Current: 1.8 161 19.51 Distance: Voltage Drop: End of Line Voltage: 0.89 End of Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 8.72% Current: 1.8 161 18.62 Distance: Voltage Drop: End of Line Voltage: 1.78 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP10 Circuit: NAC3 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.96 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guaae Ohms/ 1000' 32 14 3.07 106 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 10.3.1 P 110 0.245 32 20.015 0.385 0.0189 10.3.2 P 110 0.245 9 19.920 0.480 0.0235 10.3.3 P 110 0.245 20 19.740 0.660 0.0324 10.3.4 P 110 0.245 7 19.687 0.713 0.0350 10.3.5 P 110 0.245 9 19.633 0.767 0.0376 10.3.6 P 110 0.245 45 19.430 0.970 0.0476 10.3.7 P 110 0.245 9 19.403 0.997 0.0489 10.3.8 P 110 0.245 7 19.392 1.008 0.0494 END Z 0.000 0 19.392 1.008 0.0494 END Z 0.000 0 19.392 1.008 0.0494 END Z 0.000 0 19.392 1.008 0.0494 END Z 0.000 0 19.392 1.008 0.0494 END Z 0.000 0 19.392 1.008 0.0494 END Z 0.000 0 19.392 1.008 0.0494 END Z 0.000 0 19.392 1.008 0.0494 END Z 0.000 0 19.392 1.008 0.0494 END Z 0.000 0 19.392 1.008 0.0494 END Z 0.000 0 19.392 1.008 0.0494 END Z 0.000 0 19.392 1.008 0.0494 END Z 0.000 0 19.392 1.008 0.0494 END Z 0.000 0 19.392 1.008 0.0494 Totals: 1.96 138 CIRCUIT IS WITHIN LIMITS Percent Drop: Current: 1.96 4.94% Point to Point Method Distance: 138 End Line Voltage: Voltage Drop: of 1.01 19.39 CIRCUIT IS WITHIN LIMITS 4.07% Current: Percent Drop: 1.96 Load Centering Method Distance: 138 End Line Voltage: Voltage Drop: of 0.83 19.57 CIRCUIT IS WITHIN LIMITS Percent Drop: 8.14% Current: 1.96 End of Line Method Distance: 138 End Line Voltage: Voltage Drop: 18.74 of 1.66 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP10 Circuit: NAC4 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.472 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guaae Ohms/ 1000' 28 14 3.07 296 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 10.4.1 D 0.092 28 20.147 0.253 0.0124 10.4.2 D 0.092 19 19.986 0.414 0.0203 10.4.3 D 0.092 15 19.867 0.533 0.0261 10.4.4 D 0.092 20 19.720 0.680 0.0333 10.4.5 D 0.092 26 19.544 0.856 0.0420 10.4.6 D 0.092 20 19.420 0.980 0.0480 10.4.7 D 0.092 21 19.301 1.099 0.0539 10.4.8 D 0.092 22 19.189 1.211 0.0593 10.4.9 D 0.092 19 19.104 1.296 0.0635 10.4.10 D 0.092 20 19.025 1.375 0.0674 10.4.11 D 0.092 19 18.960 1.440 0.0706 10.4.12 D 0.092 22 18.898 1.502 0.0736 10.4.13 D 0.092 21 18.851 1.549 0.0760 10.4.14 D 0.092 11 18.832 1.568 0.0769 10.4.15 D 0.092 22 18.807 1.593 0.0781 10.4.16 D 0.092 19 18.796 1.604 0.0786 END Z 0.000 0 18.796 1.604 0.0786 END Z 0.000 0 18.796 1.604 0.0786 END Z 0.000 0 18.796 1.604 0.0786 END Z 0.000 0 18.796 1.604 0.0786 END Z 0.000 0 18.796 1.604 0.0786 Totals: 1.472 324 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 7.86% Current: 1.472 Distance: 324 Voltage Drop: End of Line Voltage: 18.80 1.60 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 7.18% Current: 1.472 Distance: 324 End Line Voltage: 18.94 Voltage Drop: 1.46 of End Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 14.35% Current: 1.472 of Distance: 324 Voltage Drop: End of Line Voltage: 17.47 2.93 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP10 Battery Calculations Circuit / Device Standy Current Alarm Current Qty Total Standy Current Total Alarm Current Power Supply 70 70 1 70 70 NAC Power NAC1 0 491 1 0 491 NAC2 0 1800 1 0 1800 NAC3 0 1960 1 0 1960 NAC4 96 1472 1 96 0 200 mA Aux Power Aux 0 0 0 0 0 Aux 0 0 0 0 0 Aux 0 0 0 0 0 TOTALS: 166 4321 Total Standy Current (Amps): 0.166 X 24 Hours: 3.984 Amphours in Standy Total Alarm Current (Amps): 4.321 X 15 Mins: 1.08 Amphours in Alarm 5.06 Required Amphours +20% Safety Total Required Amphours: 5.06 Margin 6.08 Amphours hours (2) 12V 8Ah Batteries Required. *Magnetic Door Holders are not included in the battery calculations. Power to these devices will be automatically disconnected upon Toss of NC power to reduce battery size. DEVICE LEGEND Devices Current (Milliamps) Designator Part Number Description Light Ouput 0 15cd 30cd 75cd 95cd 110cd 177cd A B C D E F G H I J K L M N 0 P Q R S T U V W X Y SB4U SB4U-LF GSA-SBT SIGA-AB4G-LF INT-7ATW INT-8ATW EG1F-HD EG1F-VM EG1F-HDVM EGCF-VM EGCF-VMH EGCF-HDVM EGCF-HDVMH G4LFWF-H G4LFWF-HVM G4HFWF-S7VMC GCHFWF-S7VMC INT-4ASW XXXX DHF-24120C CO1224T XXXX XXXX XXXX XXXX Sounder Base for V Series Detectors 520Hz Sounder Base for V Series Detectors Sounder Base for PCOS Detectors 520Hz Sounder Base for PCOS Detectors WP Wall Mount Horn/Strobe WP Wall Mount Horn/Strobe Wall Mount Horn Wall Mount Strobe Wall Mount Horn/Strobe Ceiling Mount Strobe Ceiling Mount High Candela Strobe Ceiling Mount Horn/Strobe Ceiling Mount High Candela Horn/Strobe Wall Mount 520Hz Horn Wall Mount 520Hz Horn/Strobe Wall Mount Speaker/Strobe Ceiling Mount Speaker/Strobe Weatherproof Speaker/Strobe XXXX Magnetic Door Hold-Open Carbon Monoxide Detector XXXX XXXX XXXX XXXX 28 92 52 92 180 90 22 85 102 127 135 245 160 246 285 309 94 140 273 325 333 551 111 152 281 333 324 554 166 219 266 381 437 78 101 188 245 94 140 273 325 551 159 15 75 Z N/A END OF CIRCUIT Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP11 Circuit: NAC1 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.31 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 56 14 3.07 101 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 11.1.1 P 110 0.245 56 19.950 0.450 0.0221 11.1.2 H 15 0.085 8 19.897 0.503 0.0246 11.1.3 P 110 0.245 29 19.723 0.677 0.0332 11.1.4 P 110 0.245 9 19.682 0.718 0.0352 11.1.5 P 110 0.245 29 19.595 0.805 0.0395 11.1.6 P 110 0.245 26 19.556 0.844 0.0414 END Z 0.000 0 19.556 0.844 0.0414 END Z 0.000 0 19.556 0.844 0.0414 END Z 0.000 0 19.556 0.844 0.0414 END Z 0.000 0 19.556 0.844 0.0414 END Z 0.000 0 19.556 0.844 0.0414 END Z 0.000 0 19.556 0.844 0.0414 END Z 0.000 0 19.556 0.844 0.0414 END Z 0.000 0 19.556 0.844 0.0414 END Z 0.000 0 19.556 0.844 0.0414 END Z 0.000 0 19.556 0.844 0.0414 END Z 0.000 0 19.556 0.844 0.0414 END Z 0.000 0 19.556 0.844 0.0414 END Z 0.000 0 19.556 0.844 0.0414 END Z 0.000 0 19.556 0.844 0.0414 END Z 0.000 0 19.556 0.844 0.0414 Totals: 1.31 157 CIRCUIT IS WITHIN LIMITS Percent Drop: 4.14% Current: 1.31 Point to Point Method Distance: End Line Voltage: 157 19.56 Voltage Drop: 0.84 of CIRCUIT IS WITHIN LIMITS Percent Drop: 3.10% Load Centering Method Current: 1.31 157 19.77 Distance: Voltage Drop: End of Line Voltage: 0.63 CIRCUIT IS WITHIN LIMITS Percent Drop: 6.19% Current: 1.31 End of Line Method Distance: End Line Voltage: 157 19.14 Voltage Drop: 1.26 of Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP11 Circuit: NAC2 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0.491 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 26 14 3.07 229 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 11.2.1 P 30 0.101 26 20.322 0.078 0.0038 11.2.2 P 15 0.078 15 20.286 0.114 0.0056 11.2.3 P 15 0.078 52 20.186 0.214 0.0105 11.2.4 P 15 0.078 55 20.107 0.293 0.0144 11.2.5 P 15 0.078 52 20.057 0.343 0.0168 11.2.6 P 15 0.078 55 20.031 0.369 0.0181 END Z 0.000 0 20.031 0.369 0.0181 END Z 0.000 0 20.031 0.369 0.0181 END Z 0.000 0 20.031 0.369 0.0181 END Z 0.000 0 20.031 0.369 0.0181 END Z 0.000 0 20.031 0.369 0.0181 END Z 0.000 0 20.031 0.369 0.0181 END Z 0.000 0 20.031 0.369 0.0181 END Z 0.000 0 20.031 0.369 0.0181 END Z 0.000 0 20.031 0.369 0.0181 END Z 0.000 0 20.031 0.369 0.0181 END Z 0.000 0 20.031 0.369 0.0181 END Z 0.000 0 20.031 0.369 0.0181 END Z 0.000 0 20.031 0.369 0.0181 END Z 0.000 0 20.031 0.369 0.0181 END Z 0.000 0 20.031 0.369 0.0181 T+I40:Q42otals: 0.491 255 CIRCUIT IS WITHIN LIMITS Point to Point Method Percent Drop: 1.81 % Current: 0.491 255 20.03 Distance: Voltage Drop: End of Line Voltage: 0.37 CIRCUIT IS WITHIN LIMITS Percent Drop: 1.88% Load Centering Method Current: 0.491 255 20.02 Distance: Voltage Drop: End of Line Voltage: 0.38 CIRCUIT IS WITHIN LIMITS Percent Drop: 3.77% Current: 0.491 End of Line Method 255 Distance: Voltage Drop: End of Line Voltage: 19.63 0.77 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP11 Circuit: NAC3 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guaae Ohms/ 1000' 0 14 3.07 0 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 Totals: 0 0 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 Point to Point Method Distance: 0 Voltage Drop: End of Line Voltage: 20.40 0.00 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 0 20.40 Distance: Voltage Drop: End of Line Voltage: 0.00 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 End of Line Method Distance: End Line Voltage: 0 Voltage Drop: 0.00 of 20.40 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP11 Circuit: NAC4 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.472 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guaae Ohms / 1000' 37 14 3.07 307 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 11.4.1 D 0.092 37 20.066 0.334 0.0164 11.4.2 D 0.092 23 19.871 0.529 0.0259 11.4.3 D 0.092 27 19.657 0.743 0.0364 11.4.4 D 0.092 13 19.562 0.838 0.0411 11.4.5 D 0.092 22 19.413 0.987 0.0484 11.4.6 D 0.092 20 19.288 1.112 0.0545 11.4.7 D 0.092 18 19.187 1.213 0.0595 11.4.8 D 0.092 22 19.075 1.325 0.0650 11.4.9 D 0.092 19 18.989 1.411 0.0692 11.4.10 D 0.092 22 18.902 1.498 0.0734 11.4.11 D 0.092 25 18.817 1.583 0.0776 11.4.12 D 0.092 22 18.755 1.645 0.0806 11.4.13 D 0.092 22 18.705 1.695 0.0831 11.4.14 D 0.092 19 18.673 1.727 0.0846 11.4.15 D 0.092 19 18.652 1.748 0.0857 11.4.16 D 0.092 14 18.644 1.756 0.0861 END Z 0.000 0 18.644 1.756 0.0861 END Z 0.000 0 18.644 1.756 0.0861 END Z 0.000 0 18.644 1.756 0.0861 END Z 0.000 0 18.644 1.756 0.0861 END Z 0.000 0 18.644 1.756 0.0861 Totals: 1.472 344 CIRCUIT IS WITHIN LIMITS Point to Point Method Percent Drop: 8.61% Current: 1.472 Distance: 344 Voltage Drop: End of Line Voltage: 18.64 1.76 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 7.62% Current: 1.472 Distance: 344 Voltage Drop: End of Line Voltage: 18.85 1.55 CIRCUIT IS WITHIN LIMITS Percent Drop: 15.24% Current: 1.472 End of Line Method 344 17.29 Distance: Voltage Drop: End of Line Voltage: 3.11 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP11 Battery Calculations Standy Circuit / Device Current Alarm Current Qty Total Standy Current Total Alarm Current Power Supply 70 70 1 70 70 NAC Power NAC1 0 1310 1 0 1310 NAC2 0 491 1 0 491 NAC3 0 0 0 0 0 NAC4 96 1472 1 96 0 200 mA Aux Power Aux 0 0 0 0 0 Aux 0 0 0 0 0 Aux 0 0 0 0 0 TOTALS: 166 1871 Total Standy Current (Amps): 0.166 X 24 Hours: 3.984 Amphours in Standy Total Alarm Current (Amps): 1.871 X 15 Mins: 0.47 Amphours in Alarm 4.45 Required Amphours Required Amphours: +20% Safety 4.45 5.34 Total Margin Am hours p (2) 12V 8Ah Batteries Required. *Magnetic Door Holders are not included in the battery calculations. Power to these devices will be automatically disconnected upon loss of A/C power to reduce battery size. DEVICE LEGEND Devices Current (Milliamps) Designator Part Number Description Light Ouput 0 15cd 30cd 75cd 95cd 110cd 177cd A B C D E F G H I J K L M N 0 P Q R S T U V W X Y SB4U SB4U-LF GSA-SBT SIGA-AB4G-LF INT-7ATW INT-8ATW EG1F-HD EG1F-VM EG1F-HDVM EGCF-VM EGCF-VMH EGCF-HDVM EGCF-HDVMH G4LFWF-H G4LFWF-HVM G4HFWF-S7VMC GCHFWF-S7VMC INT-4ASW XXXX DHF -24120C CO1224T XXXX XXXX XXXX XXXX Sounder Base for V Series Detectors 520Hz Sounder Base for V Series Detectors Sounder Base for PCOS Detectors 520Hz Sounder Base for PCOS Detectors WP Wall Mount Horn/Strobe WP Wall Mount Horn/Strobe Wall Mount Horn Wall Mount Strobe Wall Mount Horn/Strobe Ceiling Mount Strobe Ceiling Mount High Candela Strobe Ceiling Mount Horn/Strobe Ceiling Mount High Candela Horn/Strobe Wall Mount 520Hz Horn Wall Mount 520Hz Horn/Strobe Wall Mount Speaker/Strobe Ceiling Mount Speaker/Strobe Weatherproof Speaker/Strobe XXXX Magnetic Door Hold -Open Carbon Monoxide Detector XXXX XXXX XXXX XXXX 28 92 52 92 180 90 22 85 127 245 285 102 135 160 246 309 94 140 273 325 333 551 111 152 281 333 324 554 166 219 266 381 437 78 101 188 245 94 140 273 325 551 159 15 75 Z N/A END OF CIRCUIT Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP12 Circuit: NAC1 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.225 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 148 14 3.07 80 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 12.1.1 P 110 0.245 148 19.287 1.113 0.0546 12.1.2 P 110 0.245 22 19.154 1.246 0.0611 12.1.3 P 110 0.245 19 19.069 1.331 0.0653 12.1.4 P 110 0.245 19 19.012 1.388 0.0681 12.1.5 P 110 0.245 20 18.981 1.419 0.0695 END Z 0.000 0 18.981 1.419 0.0695 END Z 0.000 0 18.981 1.419 0.0695 END Z 0.000 0 18.981 1.419 0.0695 END Z 0.000 0 18.981 1.419 0.0695 END Z 0.000 0 18.981 1.419 0.0695 END Z 0.000 0 18.981 1.419 0.0695 END Z 0.000 0 18.981 1.419 0.0695 END Z 0.000 0 18.981 1.419 0.0695 END Z 0.000 0 18.981 1.419 0.0695 END Z 0.000 0 18.981 1.419 0.0695 END Z 0.000 0 18.981 1.419 0.0695 END Z 0.000 0 18.981 1.419 0.0695 END Z 0.000 0 18.981 1.419 0.0695 END Z 0.000 0 18.981 1.419 0.0695 END Z 0.000 0 18.981 1.419 0.0695 END Z 0.000 0 18.981 1.419 0.0695 Totals: 1.225 228 CIRCUIT IS WITHIN LIMITS Percent Drop: 6.95% Current:' 1.225 Point to Point Method Distance: End Line 228 Voltage Drop: 1.42 of Voltage: 18.98 CIRCUIT IS WITHIN LIMITS Percent Drop: 4.20% Load Centering Method Current: 1.225 228 19.54 Distance:: Voltage Drop: End of Line Voltage: 0.86 End of Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 8.41% Current:; 1.225 228 18.69 Distance: Voltage Drop: End of Line Voltage: 1.71 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP12 Circuit: NAC2 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.225 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 69 14 3.07 93 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 12.2.1 P 110 0.245 69 19.881 0.519 0.0254 12.2.2 P 110 0.245 23 19.743 0.657 0.0322 12.2.3 P 110 0.245 9 19.702 0.698 0.0342 12.2.4 P 110 0.245 38 19.588 0.812 0.0398 12.2.5 P 110 0.245 23 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 Totals: 1.225 162 CIRCUIT IS WITHIN LIMITS Percent Drop: 4.15% Current: 1.225 Point to Point Method 162 19.55 Distance: End of Line Voltage: 0.85 Voltage Drop: CIRCUIT IS WITHIN LIMITS Percent Drop: 2.99% Load Centering Method Current: 1.225 162 19.79 Distance: Voltage Drop: End of Line Voltage: 0.61 CIRCUIT IS WITHIN LIMITS Percent Drop: 5.97% Current: 1.225 End of Line Method 162 19.18 Distance: Voltage Drop: End of Line Voltage: 1.22 Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP12 Circuit: NAC3 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 2.13 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 44 14 3.07 138 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 12.3.1 P 110 0.245 44 19.825 0.575 0.0282 12.3.2 P 110 0.245 9 19.720 0.680 0.0333 12.3.3 P 110 0.245 19 19.529 0.871 0.0427 12.3.4 P 110 0.245 6 19.478 0.922 0.0452 12.3.5 P 110 0.245 9 19.414 0.986 0.0483 12.3.6 P 110 0.245 42 19.181 1.219 0.0598 12.3.7 P 110 0.245 11 19.136 1.264 0.0620 12.3.8 H 15 0.085 10 19.111 1.289 0.0632 12.3.9 P 110 0.245 25 19.060 1.340 0.0657 12.3.10 H 15 0.085 7 19.056 1.344 0.0659 END Z 0.000 0 19.056 1.344 0.0659 END Z 0.000 0 19.056 1.344 0.0659 END Z 0.000 0 19.056 1.344 0.0659 END Z 0.000 0 19.056 1.344 0.0659 END Z 0.000 0 19.056 1.344 0.0659 END Z 0.000 0 19.056 1.344 0.0659 END Z 0.000 0 19.056 1.344 0.0659 END Z 0.000 0 19.056 1.344 0.0659 END Z 0.000 0 19.056 1.344 0.0659 END Z 0.000 0 19.056 1.344 0.0659 END Z 0.000 0 19.056 1.344 0.0659 Totals: 2.13 182 CIRCUIT IS WITHIN LIMITS Percent Drop: 6.59% Current: 2.13 Point to Point Method Distance: End Line Voltage: 182 Voltage Drop: 1.34 of 19.06 CIRCUIT IS WITHIN LIMITS Percent Drop: 5.83% Load Centering Method Current: 2.13 182 19.21 Distance: Voltage Drop: End of Line Voltage: 1.19 CIRCUIT IS WITHIN LIMITS Percent Drop: 11.67% Current: 2.13 End of Line Method Distance: End Line Voltage: 182 Voltage Drop: 2.38 of 18.02 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP12 Circuit: NAC4 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.472 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guage Ohms/ 1000' 39 14 3.07 295 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 12.4.1 D 0.092 39 20.048 0.352 0.0173 12.4.2 D 0.092 20 19.878 0.522 0.0256 12.4.3 D 0.092 16 19.752 0.648 0.0318 12.4.4 D 0.092 20 19.605 0.795 0.0390 12.4.5 D 0.092 25 19.435 0.965 0.0473 12.4.6 D 0.092 19 19.317 1.083 0.0531 12.4.7 D 0.092 22 19.193 1.207 0.0592 12.4.8 D 0.092 20 19.091 1.309 0.0642 12.4.9 D 0.092 22 18.992 1.408 0.0690 12.4.10 D 0.092 18 18.921 1.479 0.0725 12.4.11 D 0.092 21 18.849 1.551 0.0760 12.4.12 D 0.092 19 18.796 1.604 0.0786 12.4.13 D 0.092 21 18.748 1.652 0.0810 12.4.14 D 0.092 11 18.730 1.670 0.0819 12.4.15 D 0.092 22 18.705 1.695 0.0831 12.4.16 D 0.092 19 18.694 1.706 0.0836 END Z 0.000 0 18.694 1.706 0.0836 END Z 0.000 0 18.694 1.706 0.0836 END Z 0.000 0 18.694 1.706 0.0836 END Z 0.000 0 18.694 1.706 0.0836 END Z 0.000 0 18.694 1.706 0.0836 Totals: 1.472 334 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 8.36% Current: 1.472 Distance: 334 Voltage Drop: End of Line Voltage: 18.69 1.71 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 7.40% Current: 1.472 Distance: 334 Voltage Drop: End of Line Voltage: 18.89 1.51 End of Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 14.80% Current: Distance: 1.472 334 Voltage Drop: End of Line Voltage: 17.38 3.02 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP12 Battery Calculations Standy Circuit / Device Current Alarm Current Qty Total Standy Current Total Alarm Current Power Supply 70 70 1 70 70 NAC Power NAC1 0 1225 1 0 1225 NAC2 0 1225 1 0 1225 NAC3 0 2130 1 0 2130 NAC4 96 1472 1 96 0 200 mA Aux Power Aux 0 0 0 0 0 Aux 0 0 0 0 0 Aux 0 0 0 0 0 TOTALS: 166 4650 Total Standy Current (Amps): 0.166 X 24 Hours: 3.984 Amphours in Standy Total Alarm Current (Amps): 4.65 X 15 Mins: 1.16 Amphours in Alarm 5.15 Required Amphours Required Amphours: +20% Safety 5.15 6'18 Tota! Margin Am hours p (2) 12V 8Ah Batteries Required. *Magnetic Door Holders are not included in the battery calculations. Power to these devices will be automatically disconnected upon Toss of NC power to reduce battery size. DEVICE LEGEND Devices Current (Milliamps) Designator Part Number Description Light Ouput 0 15cd 30cd 75cd 9Scd 110cd 177cd A B C D E F G H I J K L M N O P Q R S T U V W X Y SB4U SB4U-LF GSA-SBT SIGA-AB4G-LF INT-7ATW INT-8ATW EG1F-HD EG1F-VM EG1F-HDVM EGCF-VM EGCF-VMH EGCF-HDVM EGCF-HDVMH G4LFWF-H G4LFWF-HVM G4HFWF-S7VMC GCHFWF-S7VMC INT-4ASW XXXX DHF -24120C CO1224T XXXX XXXX XXXX XXXX Sounder Base for V Series Detectors 520Hz Sounder Base for V Series Detectors Sounder Base for PCOS Detectors 520Hz Sounder Base for PCOS Detectors WP Wall Mount Horn/Strobe WP Wall Mount Horn/Strobe Wall Mount Horn Wall Mount Strobe Wall Mount Horn/Strobe Ceiling Mount Strobe Ceiling Mount High Candela Strobe Ceiling Mount Horn/Strobe Ceiling Mount High Candela Horn/Strobe Wall Mount 520Hz Horn Wall Mount 520Hz Horn/Strobe Wall Mount Speaker/Strobe Ceiling Mount Speaker/Strobe Weatherproof Speaker/Strobe XXXX Magnetic Door Hold -Open Carbon Monoxide Detector XXXX XXXX XXXX XXXX 28 92 52 92 180 90 22 85 127 245 285 102 135 160 246 309 94 140 273 325 333 551 111 152 281 333 324 554 166 219 266 381 437 78 101 188 245 94 140 273 325 551 159 15 75 Z N/A END OF CIRCUIT Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP13 Circuit: NAC1 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0.569 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guage Ohms/ 1000' 27 14 3.07 218 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 13.1.1 P 15 0.078 27 20.306 0.094 0.0046 13.1.2 P 15 0.078 7 20.285 0.115 0.0057 13.1.3 P 30 0.101 29 20.211 0.189 0.0093 13.1.4 P 15 0.078 30 20.154 0.246 0.0121 13.1.5 P 15 0.078 52 20.079 0.321 0.0157 13.1.6 P 15 0.078 50 20.031 0.369 0.0181 13.1.7 P 15 0.078 50 20.007 0.393 0.0193 END Z 0.000 0 20.007 0.393 0.0193 END Z 0.000 0 20.007 0.393 0.0193 END Z 0.000 0 20.007 0.393 0.0193 END Z 0.000 0 20.007 0.393 0.0193 END Z 0.000 0 20.007 0.393 0.0193 END Z 0.000 0 20.007 0.393 0.0193 END Z 0.000 0 20.007 0.393 0.0193 END Z 0.000 0 20.007 0.393 0.0193 END Z 0.000 0 20.007 0.393 0.0193 END Z 0.000 0 20.007 0.393 0.0193 END Z 0.000 0 20.007 0.393 0.0193 END Z 0.000 0 20.007 0.393 0.0193 END Z 0.000 0 20.007 0.393 0.0193 END Z 0.000 0 20.007 0.393 0.0193 Totals: 0.569 245 CIRCUIT IS WITHIN LIMITS Percent Drop: 1.93% Current: 0.569 Point to Point Method End Line Distance: 245 Volta 9 e Dro 0.39 p: of Voltage: 20.01 CIRCUIT IS WITHIN LIMITS Percent Drop: 2.10% Load Centering Method Current: 0.569 I Distance:1 245 19.97 End of Line Voltage: Voltage Drop: 0.43 CIRCUIT IS WITHIN LIMITS Percent Drop: 4.20% Current: 0.569 End of Line Method End Line Voltage: Distance: 245 Volta 9 e Dro 0.86 p: of 19.54 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP13 Circuit: NAC2 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.715 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guage Ohms/ 1000' 35 14 3.07 114 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 13.2.1 P 110 0.245 35 20.031 0.369 0.0181 13.2.2 P 110 0.245 9 19.950 0.450 0.0220 13.2.3 P 110 0.245 22 19.785 0.615 0.0302 13.2.4 P 110 0.245 19 19.670 0.730 0.0358 13.2.5 P 110 0.245 22 19.571 0.829 0.0406 13.2.6 P 110 0.245 20 19.511 0.889 0.0436 13.2.7 P 110 0.245 22 19.478 0.922 0.0452 END Z 0.000 0 19.478 0.922 0.0452 END Z 0.000 0 19.478 0.922 0.0452 END Z 0.000 0 19.478 0.922 0.0452 END Z 0.000 0 19.478 0.922 0.0452 END Z 0.000 0 19.478 0.922 0.0452 END Z 0.000 0 19.478 0.922 0.0452 END Z 0.000 0 19.478 0.922 0.0452 END Z 0.000 0 19.478 0.922 0.0452 END Z 0.000 0 19.478 0.922 0.0452 END Z 0.000 0 19.478 0.922 0.0452 END Z 0.000 0 19.478 0.922 0.0452 END Z 0.000 0 19.478 0.922 0.0452 END Z 0.000 0 19.478 0.922 0.0452 END Z 0.000 0 19.478 0.922 0.0452 Totals: 1.715 149 CIRCUIT IS WITHIN LIMITS Percent Point to Point Method Current: 1.715 Drop: 4.52% Distance: 149 Voltage Drop: End of Line Voltage: 19.48 0.92 CIRCUIT IS WITHIN LIMITS Percent Drop: 3.85% Load Centering Method Current: 1.715 149 19.62 Distance: Voltage Drop: End of Line Voltage: 0.78 CIRCUIT IS WITHIN LIMITS Percent Drop: 7.69% End of Line Method Current: 1.715 149 18.83 Distance: Voltage Drop: End of Line Voltage: 1.57 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP13 Circuit: NAC3 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.8 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 152 14 3.07 104 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 13.3.1 P 110 0.245 152 18.720 1.680 0.0823 13.3.2 P 110 0.245 21 18.520 1.880 0.0922 13.3.3 P 110 0.245 16 18.391 2.009 0.0985 13.3.4 P 110 0.245 9 18.332 2.068 0.1014 13.3.5 H 15 0.085 7 18.297 2.103 0.1031 13.3.6 P 110 0.245 35 18.139 2.261 0.1108 13.3.7 P 110 0.245 9 18.112 2.288 0.1122 13.3.8 P 110 0.245 7 18.101 2.299 0.1127 END Z 0.000 0 18.101 2.299 0.1127 END Z 0.000 0 18.101 2.299 0.1127 END Z 0.000 0 18.101 2.299 0.1127 END Z 0.000 0 18.101 2.299 0.1127 END Z 0.000 0 18.101 2.299 0.1127 END Z 0.000 0 18.101 2.299 0.1127 END Z 0.000 0 18.101 2.299 0.1127 END Z 0.000 0 18.101 2.299 0.1127 END Z 0.000 0 18.101 2.299 0.1127 END Z 0.000 0 18.101 2.299 0.1127 END Z 0.000 0 18.101 2.299 0.1127 END Z 0.000 0 18.101 2.299 0.1127 END Z 0.000 0 18.101 2.299 0.1127 Totals: 1.8 256 CIRCUIT IS WITHIN LIMITS Percent Drop: 11.27% Current: 1.8 Point to Point Method Distance: End Line Voltage: 256 18.10 Voltage Drop: 2.30 of CIRCUIT IS WITHIN LIMITS Percent Drop: 6.93% Current: 1.8 Load Centering Method Distance: End Line 256 Voltage Drop: 1.41 of Voltage: 18.99 CIRCUIT IS WITHIN LIMITS Percent Drop: 13.87% Current: 1.8 End of Line Method Distance: End Line Voltage: 256 Voltage Drop: 2.83 of 17.57 Proiect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP13 Circuit: NAC4 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.012 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms / 1000' 48 14 3.07 207 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 13.4.1 D 0.092 48 20.102 0.298 0.0146 13.4.2 D 0.092 19 19.994 0.406 0.0199 13.4.3 D 0.092 22 19.883 0.517 0.0254 13.4.4 D 0.092 19 19.797 0.603 0.0296 13.4.5 D 0.092 23 19.706 0.694 0.0340 13.4.6 D 0.092 19 19.641 0.759 0.0372 13.4.7 D 0.092 18 19.591 0.809 0.0397 13.4.8 D 0.092 22 19.541 0.859 0.0421 13.4.9 D 0.092 20 19.507 0.893 0.0438 13.4.10 D 0.092 26 19.478 0.922 0.0452 13.4.11 D 0.092 19 19.467 0.933 0.0457 END Z 0.000 0 19.467 0.933 0.0457 END Z 0.000 0 19.467 0.933 0.0457 END Z 0.000 0 19.467 0.933 0.0457 END Z 0.000 0 19.467 0.933 0.0457 END Z 0.000 0 19.467 0.933 0.0457 END Z 0.000 0 19.467 0.933 0.0457 END Z 0.000 0 19.467 0.933 0.0457 END Z 0.000 0 19.467 0.933 0.0457 END Z 0.000 0 19.467 0.933 0.0457 END Z 0.000 0 19.467 0.933 0.0457 Totals: 1.012 255 CIRCUIT IS WITHIN LIMITS Point to Point Method Percent Drop: 4.57% Current: 1.012 Distance: 255 Voltage Drop: End of Line Voltage: 19.47 0.93 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 3.88% Current: 1.012 255 19.61 Distance: Voltage Drop: End of Line Voltage: 0.79 CIRCUIT IS WITHIN LIMITS Percent Drop: 7.77% Current: 1.012 End of Line Method 255 18.82 Distance: Voltage Drop: End of Line Voltage: 1.58 Prosect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP13 Battery Calculations Standy Circuit / Device Current Alarm Current Qty Total Standy Current Total Alarm Current Power Supply 70 70 1 70 70 NAC Power NAC1 0 569 1 0 569 NAC2 0 1715 1 0 1715 NAC3 0 1800 1 0 1800 NAC4 66 1012 1 66 0 200 mA Aux Power Aux 0 0 0 0 0 Aux 0 0 0 0 0 Aux 0 0 0 0 0 TOTALS: 136 4154 Total Standy Current (Amps): 0.136 X 24 Hours: 3.264 Amphours in Standy Total Alarm Current (Amps): 4.154 X 15 Mins: 1.04 Amphours in Alarm 4.30 Required Amphours Required Amphours: +20% Safety 4.30 5.16 Total Margin Am hours p (2) 12V 8Ah Batteries Required. *Magnetic Door Holders are not included in the battery calculations. Power to these devices will be automatically disconnected upon Toss of A/C power to reduce battery size. DEVICE LEGEND Devices Current (Milliamps) Designator Part Number Description LightOuput 0 15cd 30cd 75cd 95cd 110cd 177cd A B C D E F G H I J K L M N O P Q R S T U V W X Y SB4U SB4U-LF GSA-SBT SIGA-AB4G-LF INT-7ATW INT-8ATW EG1F-HD EG1F-VM EG1F-HDVM EGCF-VM EGCF-VMH EGCF-HDVM EGCF-HDVMH G4LFWF-H G4LFWF-HVM G4HFWF-S7VMC GCHFWF-S7VMC INT-4ASW XXXX DHF-24120C C01224T XXXX XXXX XXXX XXXX Sounder Base for V Series Detectors 520Hz Sounder Base for V Series Detectors Sounder Base for PCOS Detectors 520Hz Sounder Base for PCOS Detectors WP Wall Mount Horn/Strobe WP Wall Mount Horn/Strobe Wall Mount Horn Wall Mount Strobe Wall Mount Horn/Strobe Ceiling Mount Strobe Ceiling Mount High Candela Strobe Ceiling Mount Horn/Strobe Ceiling Mount High Candela Horn/Strobe Wall Mount 520Hz Horn Wall Mount 520Hz Horn/Strobe Wall Mount Speaker/Strobe Ceiling Mount Speaker/Strobe Weatherproof Speaker/Strobe XXXX Magnetic Door Hold-Open Carbon Monoxide Detector XXXX XXXX XXXX XXXX 28 92 52 92 180 90 22 85 127 245 285 102 135 160 246 309 94 140 273 325 333 551 111 152 281 333 324 554 166 219 266 381 437 78 101 188 245 94 140 273 325 551 159 15 75 Z N/A END OF CIRCUIT Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP14 Circuit: NAC1 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.47 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000` 37 14 3.07 103 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 14.1.1 P 110 0.245 37 20.066 0.334 0.0164 14.1.2 P 110 0.245 19 19.923 0.477 0.0234 14.1.3 P 110 0.245 22 19.791 0.609 0.0299 14.1.4 P 110 0.245 19 19.705 0.695 0.0341 14.1.5 P 110 0.245 23 19.636 0.764 0.0375 14.1.6 P 110 0.245 20 19.606 0.794 0.0389 END Z 0.000 0 19.606 0.794 0.0389 END Z 0.000 0 19.606 0.794 0.0389 END Z 0.000 0 19.606 0.794 0.0389 END Z 0.000 0 19.606 0.794 0.0389 END Z 0.000 0 19.606 0.794 0.0389 END Z 0.000 0 19.606 0.794 0.0389 END Z 0.000 0 19.606 0.794 0.0389 END Z 0.000 0 19.606 0.794 0.0389 END Z 0.000 0 19.606 0.794 0.0389 END Z 0.000 0 19.606 0.794 0.0389 END Z 0.000 0 19.606 0.794 0.0389 END Z 0.000 0 19.606 0.794 0.0389 END Z 0.000 0 19.606 0.794 0.0389 END Z 0.000 0 19.606 0.794 0.0389 END Z 0.000 0 19.606 0.794 0.0389 Totals: 1.47 140 CIRCUIT IS WITHIN LIMITS Percent Drop: 3.89% Current:' 1.47 Point to Point Method End Line Voltage: Distance: i 140 Voltage Drop: 0.79 of 19.61 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 3.10% Current: 1.47 Distance: ! 140 19.77 End of Line Voltage: Voltage Drop: 0.63 CIRCUIT IS WITHIN LIMITS Percent Drop: 6.19% Current: 1.47 End of Line Method End Line Voltage: Distance: 140 Voltage Drop: 1.26 of 19.14 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP14 Circuit: NAC2 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.225 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 152 14 3.07 76 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 14.2.1 P 110 0.245 152 19.257 1.143 0.0560 14.2.2 P 110 0.245 18 19.148 1.252 0.0614 14.2.3 P 110 0.245 9 19.108 1.292 0.0633 14.2.4 P 110 0.245 40 18.987 1.413 0.0692 14.2.5 P 110 0.245 9 18.974 1.426 0.0699 END Z 0.000 0 18.974 1.426 0.0699 END Z 0.000 0 18.974 1.426 0.0699 END Z 0.000 0 18.974 1.426 0.0699 END Z 0.000 0 18.974 1.426 0.0699 END Z 0.000 0 18.974 1.426 0.0699 END Z 0.000 0 18.974 1.426 0.0699 END Z 0.000 0 18.974 1.426 0.0699 END Z 0.000 0 18.974 1.426 0.0699 END Z 0.000 0 18.974 1.426 0.0699 END Z 0.000 0 18.974 1.426 0.0699 END Z 0.000 0 18.974 1.426 0.0699 END Z 0.000 0 18.974 1.426 0.0699 END Z 0.000 0 18.974 1.426 0.0699 END Z 0.000 0 18.974 1.426 0.0699 END Z 0.000 0 18.974 1.426 0.0699 END Z 0.000 0 18.974 1.426 0.0699 Totals: 1.225 228 CIRCUIT IS WITHIN LIMITS Percent Drop: 6.99% Point to Point Method Current: 1.225 228 18.97 Distance: End of Line Voltage: 1.43 Voltage Drop: CIRCUIT IS WITHIN LIMITS Percent Drop: 4.20% Load Centering Method Current: 1.225 228 19.54 Distance: Voltage Drop: End of Line Voltage: 0.86 CIRCUIT IS WITHIN LIMITS Percent Drop: 8.41% Current: 1.225 End of Line Method 228 18.69 Distance: Voltage Drop: End of Line Voltage: 1.71 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP14 Circuit: NAC3 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.47 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 101 14 3.07 119 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 14.3.1 P 110 0.245 101 19.488 0.912 0.0447 14.3.2 P 110 0.245 29 19.270 1.130 0.0554 14.3.3 P 110 0.245 17 19.168 1.232 0.0604 14.3.4 P 110 0.245 34 19.015 1.385 0.0679 14.3.5 P 110 0.245 16 18.966 1.434 0.0703 14.3.6 P 110 0.245 23 18.932 1.468 0.0720 END Z 0.000 0 18.932 1.468 0.0720 END Z 0.000 0 18.932 1.468 0.0720 END Z 0.000 0 18.932 1.468 0.0720 END Z 0.000 0 18.932 1.468 0.0720 END Z 0.000 0 18.932 1.468 0.0720 END Z 0.000 0 18.932 1.468 0.0720 END Z 0.000 0 18.932 1.468 0.0720 END Z 0.000 0 18.932 1.468 0.0720 END Z 0.000 0 18.932 1.468 0.0720 END Z 0.000 0 18.932 1.468 0.0720 END Z 0.000 0 18.932 1.468 0.0720 END Z 0.000 0 18.932 1.468 0.0720 END Z 0.000 0 18.932 1.468 0.0720 END Z 0.000 0 18.932 1.468 0.0720 END Z 0.000 0 18.932 1.468 0.0720 Totals: 1.47 220 CIRCUIT IS WITHIN LIMITS Percent Drop: 7.20% Current: 1.47 Point to Point Method Distance: End Line 220 Voltage Drop: 1.47 of Voltage: 18.93 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 4.87% Current: 1.47 220 19.41 Distance: Voltage Drop: End of Line Voltage: 0.99 CIRCUIT IS WITHIN LIMITS Percent Drop: 9.73% Current: 1.47 End of Line Method Distance: End Line Voltage: 220 Voltage Drop: 1.99 of 18.41 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP14 Circuit: NAC4 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.472 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaoe Ohms/ 1000' 49 14 3.07 303 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 14.4.1 D 0.092 49 19.957 0.443 0.0217 14.4.2 D 0.092 19 19.796 0.604 0.0296 14.4.3 D 0.092 25 19.598 0.802 0.0393 14.4.4 D 0.092 14 19.496 0.904 0.0443 14.4.5 D 0.092 18 19.374 1.026 0.0503 14.4.6 D 0.092 16 19.274 1.126 0.0552 14.4.7 D 0.092 19 19.167 1.233 0.0604 14.4.8 D 0.092 28 19.025 1.375 0.0674 14.4.9 D 0.092 17 18.948 1.452 0.0712 14.4.10 D 0.092 20 18.869 1.531 0.0751 14.4.11 D 0.092 23 18.791 1.609 0.0789 14.4.12 D 0.092 22 18.729 1.671 0.0819 14.4.13 D 0.092 23 18.677 1.723 0.0845 14.4.14 D 0.092 19 18.644 1.756 0.0861 14.4.15 D 0.092 19 18.623 1.777 0.0871 14.4.16 D 0.092 21 18.611 1.789 0.0877 END Z 0.000 0 18.611 1.789 0.0877 END Z 0.000 0 18.611 1.789 0.0877 END Z 0.000 0 18.611 1.789 0.0877 END Z 0.000 0 18.611 1.789 , 0.0877 END Z 0.000 0 18.611 1.789 0.0877 Totals: 1.472 352 CIRCUIT IS WITHIN LIMITS Percent Drop: 8.77% Current: 1.472 Point to Point Method Distance: 352 Voltage Drop: End of Line Voltage: 18.61 1.79 CIRCUIT IS WITHIN LIMITS Percent Drop: 7.80% Current: 1.472 Load Centering Method 352 18.81 Distance: Voltage Drop: End of Line Voltage: 1.59 CIRCUIT IS WITHIN LIMITS Percent Drop: 15.60% Current: 1.472 End of Line Method 352 17.22 Distance: Voltage Drop: End of Line Voltage: 3.18 Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP14 Battery Calculations Standy Circuit / Device Current Alarm Current Qty Total Standy Current Total Alarm Current Power Supply 70 70 1 70 70 NAC Power NAC1 0 1470 1 0 1470 NAC2 0 1225 1 0 1225 NAC3 0 1470 1 0 1470 NAC4 96 1472 1 96 0 200 mA Aux Power Aux 0 0 0 0 0 Aux 0 0 0 0 0 Aux 0 0 0 0 0 TOTALS: 166 4235 Total Standy Current (Amps): 0.166 X 24 Hours: 3.984 Amphours in Standy Total Alarm Current (Amps): 4.235 X 15 Mins: 1.06 Amphours in Alarm 5.04 Required Amphours Required Amphours: +20% Safety 5.04 6.05 Total Margin Am hours p (2) 12V 8Ah Batteries Required. *Magnetic Door Holders are not included in the battery calculations. Power to these devices will be automatically disconnected upon loss of A/C power to reduce battery size. DEVICE LEGEND Devices Current (Milliamps) Designator Part Number Description LightOuput 0 15cd 30cd 75cd 95cd 110cd 177cd -<X*< c H (n71O-J O z K r T. — 2 O m m O n O> SB4U SB4U-LF GSA-SBT SIGA-AB4G-LF INT-7ATW INT-8ATW EG1F-HD EG1 F-VM EG1F-HDVM EGCF-VM EGCF-VMH EGCF-HDVM EGCF-HDVMH G4LFWF-H G4LFWF-HVM G4HFWF-S7VMC GCHFWF-S7VMC INT-4ASW XXXX DHF-24120C C01224T XXXX XXXX XXXX )(XXX Sounder Base for V Series Detectors 520Hz Sounder Base for V Series Detectors Sounder Base for PCOS Detectors 520Hz Sounder Base for PCOS Detectors WP Wall Mount Horn/Strobe WP Wall Mount Horn/Strobe Wall Mount Horn Wall Mount Strobe Wall Mount Horn/Strobe Ceiling Mount Strobe Ceiling Mount High Candela Strobe Ceiling Mount Horn/Strobe Ceiling Mount High Candela Horn/Strobe Wall Mount 520Hz Horn Wall Mount 520Hz Horn/Strobe Wall Mount Speaker/Strobe Ceiling Mount Speaker/Strobe Weatherproof Speaker/Strobe XXXX Magnetic Door Hold-Open Carbon Monoxide Detector XXXX XXXX XXXX XXXX 28 92 52 92 180 90 22 85 127 245 285 102 135 160 246 309 94 140 273 325 333 551 111 152 281 333 324 554 166 219 266 381 437 78 101 188 245 94 140 273 325 551 159 15 75 Z N/A END OF CIRCUIT Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP15 Circuit: NAC1 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.225 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 11 14 3.07 93 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 15.1.1 P 110 0.245 11 20.317 0.083 0.0041 15.1.2 P 110 0.245 27 20.155 0.245 0.0120 15.1.3 P 110 0.245 27 20.033 0.367 0.0180 15.1.4 P 110 0.245 9 20.006 0.394 0.0193 15.1.5 P 110 0.245 30 19.961 0.439 0.0215 END Z 0.000 0 19.961 0.439 0.0215 END Z 0.000 0 19.961 0.439 0.0215 END Z 0.000 0 19.961 0.439 0.0215 END Z 0.000 0 19.961 0.439 0.0215 END Z 0.000 0 19.961 0.439 0.0215 END Z 0.000 0 19.961 0.439 0.0215 END Z 0.000 0 19.961 0.439 0.0215 END Z 0.000 0 19.961 0.439 0.0215 END Z 0.000 0 19.961 0.439 0.0215 END Z 0.000 0 19.961 0.439 0.0215 END Z 0.000 0 19.961 0.439 0.0215 END Z 0.000 0 19.961 0.439 0.0215 END Z 0.000 0 19.961 0.439 0.0215 END Z 0.000 0 19.961 0.439 0.0215 END Z 0.000 0 19.961 0.439 0.0215 END Z 0.000 0 19.961 0.439 0.0215 Totals: 1.225 104 CIRCUIT IS WITHIN LIMITS Percent Drop: 2.15% Current: 1.225 Point to Point Method Distance: End Line Voltage: 104 19.96 Voltage Drop: 0.44 of CIRCUIT IS WITHIN LIMITS Percent Drop: 1.92% Load Centering Method Current: 1.225 104 20.01 Distance: Voltage Drop: End of Line Voltage: 0.39 End of Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 3.83% Current: ; 1.225 104 19.62 Distance: Voltage Drop: End of Line Voltage: 0.78 PrOlect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP15 Circuit: NAC2 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0.491 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms / 1000' 7 14 3.07 237 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 15.2.1 P 30 0.101 7 20.379 0.021 0.0010 15.2.2 P 15 0.078 24 20.321 0.079 0.0039 15.2.3 P 15 0.078 52 20.222 0.178 0.0087 15.2.4 P 15 0.078 55 20.143 0.257 0.0126 15.2.5 P 15 0.078 52 20.093 0.307 0.0150 15.2.6 P 15 0.078 54 20.067 0.333 0.0163 END Z 0.000 0 20.067 0.333 0.0163 END Z 0.000 0 20.067 0.333 0.0163 END Z 0.000 0 20.067 0.333 0.0163 END Z 0.000 0 20.067 0.333 0.0163 END Z 0.000 0 20.067 0.333 0.0163 END Z 0.000 0 20.067 0.333 0.0163 END Z 0.000 0 20.067 0.333 0.0163 END Z 0.000 0 20.067 0.333 0.0163 END Z 0.000 0 20.067 0.333 0.0163 END Z 0.000 0 20.067 0.333 0.0163 END Z 0.000 0 20.067 0.333 0.0163 END Z 0.000 0 20.067 0.333 0.0163 END Z 0.000 0 20.067 0.333 0.0163 END Z 0.000 0 20.067 0.333 0.0163 END Z 0.000 0 20.067 0.333 0.0163 Totals: 0.491 244 CIRCUIT IS WITHIN LIMITS Point to Point Method Percent Drop: 1.63% Current: 0.491 244 20.07 Distance: Voltage Drop: End of Line Voltage: 0.33 CIRCUIT IS WITHIN LIMITS Load Centering Method Current: 0.491 Percent Drop: 1.80% 244 20.03 Distance: Voltage Drop: End of Line Voltage: 0.37 CIRCUIT IS WITHIN LIMITS End of Line Method Percent Drop: 3.61% Current: 0.491 244 19.66 Distance: Voltage Drop: End of Line Voltage: 0.74 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP15 Circuit: NAC3 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 0 14 3.07 0 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 Totals: 0 0 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 Point to Point Method Distance: End 0 Voltage Drop: 0.00 of Line Voltage: 20.40 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 0 20.40 Distance: Voltage Drop: End of Line Voltage: 0.00 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 End of Line Method Distance: End Line Voltage: 0 Voltage Drop: 0.00 of 20.40 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP15 Circuit: NAC4 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.012 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guage Ohms/ 1000' 15 14 3.07 230 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 15.4.1 D 0.092 15 20.307 0.093 0.0046 15.4.2 D 0.092 19 20.199 0.201 0.0098 15.4.3 D 0.092 29 20.052 0.348 0.0171 15.4.4 D 0.092 21 19.957 0.443 0.0217 15.4.5 D 0.092 15 19.898 0.502 0.0246 15.4.6 D 0.092 27 19.806 0.594 0.0291 15.4.7 D 0.092 19 19.753 0.647 0.0317 15.4.8 D 0.092 25 19.696 0.704 0.0345 15.4.9 D 0.092 27 19.650 0.750 0.0367 15.4.10 D 0.092 24 19.623 0.777 0.0381 15.4.11 D 0.092 24 19.610 0.790 0.0387 END Z 0.000 0 19.610 0.790 0.0387 END Z 0.000 0 19.610 0.790 0.0387 END Z 0.000 0 19.610 0.790 0.0387 END Z 0.000 0 19.610 0.790 0.0387 END Z 0.000 0 19.610 0.790 0.0387 END Z 0.000 0 19.610 0.790 0.0387 END Z 0.000 0 19.610 0.790 0.0387 END Z 0.000 0 19.610 0.790 0.0387 END Z 0.000 0 19.610 0.790 0.0387 END Z 0.000 0 19.610 0.790 0.0387 Totals: 1.012 245 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 3.87% Current: Distance: 1.012 245 Voltage Drop: End of Line Voltage: 19.61 0.79 CIRCUIT IS WITHIN LIMITS Percent Drop: 3.73% Current: 1.012 Load Centering Method 245 Distance: Voltage Drop: End of Line Voltage: 19.64 0.76 CIRCUIT IS WITHIN LIMITS Percent Drop: 7.46% Current: 1.012 End of Line Method 245 18.88 Distance: Voltage Drop: End of Line Voltage: 1.52 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP15 Battery Calculations Standy Circuit / Device Current Alarm Current Qty Total Standy Current Total Alarm Current Power Supply 70 70 1 70 70 NAC Power NAC1 0 1225 1 0 1225 NAC2 0 491 1 0 491 NAC3 0 0 0 0 0 NAC4 66 1012 1 66 0 200 mA Aux Power Aux 0 0 0 0 0 Aux 0 0 0 0 0 Aux 0 0 0 0 0 TOTALS: 136 1786 Total Standy Current (Amps): 0.136 X 24 Hours: 3.264 Amphours in Standy Total Alarm Current (Amps): 1.786 X 15 Mins: 0.45 Amphours in Alarm 3.71 Required Amphours Required Amphours: +20% Safety 3.71 4.45 Total Margin Am hours p (2) 12V 8Ah Batteries Required. *Magnetic Door Holders are not included in the battery calculations. Power to these devices will be automatically disconnected upon loss of NC power to reduce battery size. DEVICE LEGEND Devices Current (Milliamps) Designator Part Number Description Light Ouput 0 15cd 30cd 75cd 95cd 110cd 177cd A B C D E F G H I J K L M N 0 P Q R S T U V W X Y SB4U SB4U-LF GSA-SBT SIGA-AB4G-LF INT-7ATW INT-8ATW EG1F-HD EG1F-VM EG1F-HDVM EGCF-VM EGCF-VMH EGCF-HDVM EGCF-HDVMH G4LFWF-H G4LFWF-HVM G4HFWF-S7VMC GCHFWF-S7VMC INT-4ASW XXXX DHF -24120C CO1224T XXXX )(XXX XXXX XXXX Sounder Base for V Series Detectors 520Hz Sounder Base for V Series Detectors Sounder Base for PCOS Detectors 520Hz Sounder Base for PCOS Detectors WP Wall Mount Horn/Strobe WP Wall Mount Horn/Strobe Wall Mount Horn Wall Mount Strobe Wall Mount Horn/Strobe Ceiling Mount Strobe Ceiling Mount High Candela Strobe Ceiling Mount Horn/Strobe Ceiling Mount High Candela Horn/Strobe Wall Mount 520Hz Horn Wall Mount 520Hz Horn/Strobe Wall Mount Speaker/Strobe Ceiling Mount Speaker/Strobe Weatherproof Speaker/Strobe )(XXX Magnetic Door Hold -Open Carbon Monoxide Detector XXXX XXXX XXXX XXXX 28 92 52 92 180 90 22 85 127 245 285 102 135 160 246 309 94 140 273 325 333 551 111 152 281 333 324 554 166 219 266 381 437 78 101 188 245 94 140 273 325 551 159 15 75 Z N/A END OF CIRCUIT Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP16 Circuit: NAC1 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.715 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 165 14 3.07 96 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 16.1.1 P 110 0.245 165 18.663 1.737 0.0852 16.1.2 P 110 0.245 19 18.491 1.909 0.0936 16.1.3 P 110 0.245 18 18.356 2.044 0.1002 16.1.4 P 110 0.245 9 18.302 2.098 0.1029 16.1.5 P 110 0.245 34 18.148 2.252 0.1104 16.1.6 P 110 0.245 9 18.121 2.279 0.1117 16.1.7 P 110 0.245 7 18.110 2.290 0.1122 END Z 0.000 0 18.110 2.290 0.1122 END Z 0.000 0 18.110 2.290 0.1122 END Z 0.000 0 18.110 2.290 0.1122 END Z 0.000 0 18.110 2.290 0.1122 END Z 0.000 0 18.110 2.290 0.1122 END Z 0.000 0 18.110 2.290 0.1122 END Z 0.000 0 18.110 2.290 0.1122 END Z 0.000 0 18.110 2.290 0.1122 END Z 0.000 0 18.110 2.290 0.1122 END Z 0.000 0 18.110 2.290 0.1122 END Z 0.000 0 18.110 2.290 0.1122 END Z 0.000 0 18.110 2.290 0.1122 END Z 0.000 0 18.110 2.290 0.1122 END Z 0.000 0 18.110 2.290 0.1122 Totals: 1.715 261 CIRCUIT IS WITHIN LIMITS Percent Drop: 11.22% Current: 1.715 Point to Point Method Distance: 261 Voltage Drop: End of Line Voltage: 18.11 2.29 CIRCUIT IS WITHIN LIMITS Percent Drop: 6.74% Current: 1.715 Load Centering Method Distance: End Line Voltage: 261 Voltage Drop:; 1.37 of 19.03 CIRCUIT IS WITHIN LIMITS Percent Drop: 13.47% Current: 1.715 End of Line Method Distance: End Line Voltage: 261 17.65 Voltage Drop: 2.75 of Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP16 Circuit: NAC2 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 2.13 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guage Ohms/ 1000' 41 14 3.07 131 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 16.2.1 P 110 0.245 41 19.864 0.536 0.0263 16.2.2 P 110 0.245 9 19.760 0.640 0.0314 16.2.3 H 15 0.085 20 19.558 0.842 0.0413 16.2.4 P 110 0.245 12 19.444 0.956 0.0469 16.2.5 P 110 0.245 9 19.371 1.029 0.0504 16.2.6 P 110 0.245 6 19.332 1.068 0.0524 16.2.7 H 15 0.085 8 19.292 1.108 0.0543 16.2.8 P 110 0.245 51 19.062 1.338 0.0656 16.2.9 P 110 0.245 7 19.041 1.359 0.0666 16.2.10 P 110 0.245 9 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0,0673 Totals: 2.13 172 CIRCUIT IS WITHIN LIMITS Percent Drop: 6.73% Current: 2.13 Point to Point Method 172 19.03 Distance: End of Line Voltage: 1.37 Voltage Drop: CIRCUIT IS WITHIN LIMITS Percent Drop: 5.51% Load Centering Method Current: 2.13 172 19.28 Distance: Voltage Drop: End of Line Voltage: 1.12 CIRCUIT IS WITHIN LIMITS Percent Drop: 11.03% Current: 2.13 End of Line Method 172 18.15 Distance: Voltage Drop: End of Line Voltage: 2.25 Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP16 Circuit: NAC3 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.8 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms / 1000' 48 14 3.07 123 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 16.3.1 P 110 0.245 48 19.870 0.530 0.0260 16.3.2 P 110 0.245 9 19.784 0.616 0.0302 16.3.3 P 110 0.245 22 19.607 0.793 0.0389 16.3.4 H 15 0.085 9 19.548 0.852 0.0418 16.3.5 P 110 0.245 20 19.427 0.973 0.0477 16.3.6 P 110 0.245 22 19.328 1.072 0.0525 16.3.7 P 110 0.245 20 19.268 1.132 0.0555 16.3.8 P 110 0.245 21 19.236 1.164 0.0570 END Z 0.000 0 19.236 1.164 0.0570 END Z 0.000 0 19.236 1.164 0.0570 END Z 0.000 0 19.236 1.164 0.0570 END Z 0.000 0 19.236 1.164 0.0570 END Z 0.000 0 19.236 1.164 0.0570 END Z 0.000 0 19.236 1.164 0.0570 END Z 0.000 0 19.236 1.164 0.0570 END Z 0.000 0 19.236 1.164 0.0570 END Z 0.000 0 19.236 1.164 0.0570 END Z 0.000 0 19.236 1.164 0.0570 END Z 0.000 0 19.236 1.164 0.0570 END Z 0.000 0 19.236 1.164 0.0570 END Z 0.000 0 19.236 1.164 0.0570 Totals: 1.8 171 CIRCUIT IS WITHIN LIMITS Percent Drop: 5.70% Current: 1.8 Point to Point Method Distance: End Line Voltage: 171 Voltage Drop: 1.16 of 19.24 CIRCUIT IS WITHIN LIMITS Percent Drop: 4.63% Current: 1.8 Load Centering Method Distance: End Line Voltage: 171 19.46 Voltage Drop: 0.94 of CIRCUIT IS WITHIN LIMITS Percent Drop: 9.26% Current: 1.8 End of Line Method Distance: End Line Voltage: 171 Voltage Drop: 1.89 of 18.51 Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP16 Circuit: NAC4 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.472 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 41 14 3.07 312 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 16.4.1 D 0.092 41 20.029 0.371 0.0182 16.4.2 D 0.092 27 19.801 0.599 0.0294 16.4.3 D 0.092 16 19.674 0.726 0.0356 16.4.4 D 0.092 20 19.527 0.873 0.0428 16.4.5 D 0.092 26 19.351 1.049 0.0514 16.4.6 D 0.092 20 19.227 1.173 0.0575 16.4.7 D 0.092 22 19.102 1.298 0.0636 16.4.8 D 0.092 20 19.001 1.399 0.0686 16.4.9 D 0.092 21 18.906 1.494 0.0732 16.4.10 D 0.092 22 18.819 1.581 0.0775 16.4.11 D 0.092 19 18.755 1.645 0.0807 16.4.12 D 0.092 23 18.690 1.710 0.0838 16.4.13 D 0.092 21 18.642 1.758 0.0862 16.4.14 D 0.092 12 18.622 1.778 0.0872 16.4.15 D 0.092 23 18.596 1.804 0.0884 16.4.16 D 0.092 20 18.584 1.816 0.0890 END Z 0.000 0 18.584 1.816 0.0890 END Z 0.000 0 18.584 1.816 0.0890 END Z 0.000 0 18.584 1.816 0.0890 END Z 0.000 0 18.584 1.816 0.0890 END Z 0.000 0 18.584 1.816 0.0890 Totals: 1.472 353 CIRCUIT IS WITHIN LIMITS Percent Drop: 8.90% Current: 1.472 Point to Point Method 353 18.58 Distance: Voltage Drop: End of Line Voltage: 1.82 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 7.82% Current: 1.472 Distance: 353 Voltage Drop: End of Line Voltage: 18.80 1.60 CIRCUIT IS WITHIN LIMITS Percent Drop: 15.64% Current: 1.472 End of Line Method 353 17.21 Distance: Voltage Drop: End of Line Voltage: 3.19 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP16 Battery Calculations Standy Circuit / Device Current Alarm Current Qty Total Standy Current Total Alarm Current Power Supply 70 70 1 70 70 NAC Power NAC1 0 1715 1 0 1715 NAC2 0 2130 1 0 2130 NAC3 0 1800 1 0 1800 NAC4 96 1472 1 96 0 200 mA Aux Power Aux 0 0 0 0 0 Aux 0 0 0 0 0 Aux 0 0 0 0 0 TOTALS: 166 5715 Total Standy Current (Amps): 0.166 X 24 Hours: 3.984 Amphours in Standy Total Alarm Current (Amps): 5.715 X 15 Mins: 1.43 Amphours in Alarm 5.41 Required Amphours Required Amphours: +20% Safety 5.41 6.50 Tota! Margin Am hours p (2) 12V 8Ah Batteries Required. *Magnetic Door Holders are not included in the battery calculations. Power to these devices will be automatically disconnected upon Toss of A/C power to reduce battery size. DEVICE LEGEND Devices Current (Milliamps) Designator Part Number Description Light Ouput 0 15cd 30cd 75cd 95cd 110cd 177cd A B C D E F G H I J K L M N 0 P Q R S T U V W X Y SB4U SB4U-LF GSA-SBT SIGA-AB4G-LF INT-7ATW INT-8ATW EG1F-HD EG1F-VM EG1 F-HDVM EGCF-VM EGCF-VMH EGCF-HDVM EGCF-HDVMH G4LFWF-H G4LFWF-HVM G4HFWF-S7VMC GCHFWF-S7VMC INT-4ASW XXXX DHF -24120C CO1224T XXXX XXXX XXXX XXXX Sounder Base for V Series Detectors 520Hz Sounder Base for V Series Detectors Sounder Base for PCOS Detectors 520Hz Sounder Base for PCOS Detectors WP Wall Mount Horn/Strobe WP Wall Mount Horn/Strobe Wall Mount Horn Wall Mount Strobe Wall Mount Horn/Strobe Ceiling Mount Strobe Ceiling Mount High Candela Strobe Ceiling Mount Horn/Strobe Ceiling Mount High Candela Horn/Strobe Wall Mount 520Hz Horn Wall Mount 520Hz Horn/Strobe Wall Mount Speaker/Strobe Ceiling Mount Speaker/Strobe Weatherproof Speaker/Strobe XXXX Magnetic Door Hold -Open Carbon Monoxide Detector XXXX XXXX XXXX XXXX 28 92 52 92 180 90 22 85 102 127 135 245 285 160 246 309 94 140 273 325 333 551 111 152 281 333 324 554 166 219 266 381 437 78 101 188 245 94 140 273 325 551 159 15 75 Z N/A END OF CIRCUIT Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP17 Circuit: NAC1 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0.468 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 15 14 3.07 223 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 17.1.1 P 15 0.078 15 20.357 0.043 0.0021 17.1.2 P 15 0.078 10 20.333 0.067 0.0033 17.1.3 P 15 0.078 52 20.233 0.167 0.0082 17.1.4 P 15 0.078 55 20.154 0.246 0.0120 17.1.5 P 15 0.078 52 20.105 0.295 0.0145 17.1.6 P 15 0.078 54 20.079 0.321 0.0158 END Z 0.000 0 20.079 0.321 0.0158 END Z 0.000 0 20.079 0.321 0.0158 END Z 0.000 0 20.079 0.321 0.0158 END Z 0.000 0 20.079 0.321 0.0158 END Z 0.000 0 20.079 0.321 0.0158 END Z 0.000 0 20.079 0.321 0.0158 END Z 0.000 0 20.079 0.321 0.0158 END Z 0.000 0 20.079 0.321 0.0158 END Z 0.000 0 20.079 0.321 0.0158 END Z 0.000 0 20.079 0.321 0.0158 END Z 0.000 0 20.079 0.321 0.0158 END Z 0.000 0 20.079 0.321 0.0158 END Z 0.000 0 20.079 0.321 0.0158 END Z 0.000 0 20.079 0.321 0.0158 END Z 0.000 0 20.079 0.321 0.0158 Totals: 0.468 238 CIRCUIT IS WITHIN LIMITS Percent Drop: 1.58% Current: 0.468 Point to Point Method Distance: End Line Voltage: 238 Voltage Drop: 0.32 of 20.08 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 1.68% Current: 0.468 238 20.06 Distance: Voltage Drop: End of Line Voltage: 0.34 CIRCUIT IS WITHIN LIMITS Percent Drop: 3.35% Current:, 0.468 End of Line Method Distance: End Line Voltage: 238 19.72 Voltage Drop: 0.68 of Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP17 Circuit: NAC2 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.225 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 147 14 3.07 74 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 17.2.1 P 110 0.245 147 19.294 1.106 0.0542 17.2.2 P 110 0.245 16 19.198 1.202 0.0589 17.2.3 P 110 0.245 19 19.112 1.288 0.0631 17.2.4 P 110 0.245 18 19.058 1.342 0.0658 17.2.5 P 110 0.245 21 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 Totals: 1.225 221 CIRCUIT IS WITHIN LIMITS Percent Drop: 6.73% Point to Point Method Current: 1.225 Distance: 221 Voltage Drop: End of Line Voltage: 19.03 1.37 CIRCUIT IS WITHIN LIMITS Load Centering Method Current: 1.225 Percent Drop: 4.07% 221 19.57 Distance: Voltage Drop: End of Line Voltage: 0.83 CIRCUIT IS WITHIN LIMITS Percent Drop: 8.15% Current: 1.225 End of Line Method 221 18.74 Distance: Voltage Drop: End of Line Voltage: 1.66 Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP17 Circuit: NAC3 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.31 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms / 1000' 65 14 3.07 102 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 17.3.1 P 110 0.245 65 19.877 0.523 0.0256 17.3.2 P 110 0.245 33 19.661 0.739 0.0362 17.3.3 P 110 0.245 9 19.616 0.784 0.0384 17.3.4 P 110 0.245 29 19.514 0.886 0.0434 17.3.5 H 15 0.085 8 19.497 0.903 0.0442 17.3.6 P 110 0.245 23 19.463 0.937 0.0459 END Z 0.000 0 19.463 0.937 0.0459 END Z 0.000 0 19.463 0.937 0.0459 END Z 0.000 0 19.463 0.937 0.0459 END Z 0.000 0 19.463 0.937 0.0459 END Z 0.000 0 19.463 0.937 0.0459 END Z 0.000 0 19.463 0.937 0.0459 END Z 0.000 0 19.463 0.937 0.0459 END Z 0.000 0 19.463 0.937 0.0459 END Z 0.000 0 19.463 0.937 0.0459 END Z 0.000 0 19.463 0.937 0.0459 END Z 0.000 0 19.463 0.937 0.0459 END Z 0.000 0 19.463 0.937 0.0459 END Z 0.000 0 19.463 0.937 0.0459 END Z 0.000 0 19.463 0.937 0.0459 END Z 0.000 0 19.463 0.937 0.0459 Totals: 1.31 167 CIRCUIT IS WITHIN LIMITS Percent Drop: 4.59% Current: 1.31 Point to Point Method Distance: 167 Voltage Drop: End of Line Voltage: 19.46 0.94 CIRCUIT IS WITHIN LIMITS Percent Drop: 3.29% Current: 1.31 Load Centering Method Distance: 167 Voltage Drop: End of Line Voltage: 19.73 0.67 End of Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 6.58% Current: 1.31 167 Distance: Voltage Drop: End of Line Voltage: 19.06 1.34 PrOiect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP17 Circuit: NAC4 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.472 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guage Ohms/ 1000' 71 14 3.07 302 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 17.4.1 D 0.092 71 19.758 0.642 0.0315 17.4.2 D 0.092 20 19.589 0.811 0.0398 17.4.3 D 0.092 19 19.439 0.961 0.0471 17.4.4 D 0.092 20 19.292 1.108 0.0543 17.4.5 D 0.092 17 19.176 1.224 0.0600 17.4.6 D 0.092 21 19.046 1.354 0.0664 17.4.7 D 0.092 18 18.944 1.456 0.0714 17.4.8 D 0.092 23 18.827 1.573 0.0771 17.4.9 D 0.092 19 18.742 1.658 0.0813 17.4.10 D 0.092 19 18.666 1.734 0.0850 17.4.11 D 0.092 25 18.582 1.818 0.0891 17.4.12 D 0.092 17 18.534 1.866 0.0915 17.4.13 D 0.092 25 18.477 1.923 0.0943 17.4.14 D 0.092 19 18.445 1.955 0.0958 17.4.15 D 0.092 19 18.423 1.977 0.0969 17.4.16 D 0.092 21 18.412 1.988 0.0975 END Z 0.000 0 18.412 1.988 0.0975 END Z 0.000 0 18.412 1.988 0.0975 END Z 0.000 0 18.412 1.988 0.0975 END Z 0.000 0 18.412 1.988 0.0975 END Z 0.000 0 18.412 1.988 0.0975 Totals: 1.472 373 CIRCUIT IS WITHIN LIMITS Point to Point Method Percent Drop: 9.75% Current: 1.472 Distance: 373 Voltage Drop: End of Line Voltage: 18.41 1.99 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 8.26% Current: 1.472 Distance: 373 Voltage Drop: End of Line Voltage: 18.71 1.69 CIRCUIT IS WITHIN LIMITS Percent Drop: 16.53% Current: 1.472 End of Line Method 373 17.03 Distance: Voltage Drop: End of Line Voltage: 3.37 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP17 Battery Calculations Standy Circuit / Device Current Alarm Current Qty Total Standy Current Total Alarm Current Power Supply 70 70 1 70 70 NAC Power NAC1 0 468 1 0 468 NAC2 0 1225 1 0 1225 NAC3 0 1310 1 0 1310 NAC4 96 1472 1 96 0 200 mA Aux Power Aux 0 0 0 0 0 Aux 0 0 0 0 0 Aux 0 0 0 0 0 TOTALS: 166 3073 Total Standy Current (Amps): 0.166 X 24 Hours: 3.984 Amphours in Standy Total Alarm Current (Amps): 3.073 X 15 Mins: 0.77 Amphours in Alarm 4.75 Required Amphours Required Amphours: +20% Safety 4.75 5'70 Total Margin Am hours p (2) 12V 8Ah Batteries Required. *Magnetic Door Holders are not included in the battery calculations. Power to these devices will be automatically disconnected upon loss of NC power to reduce battery size. DEVICE LEGEND Devices Current (Milliamps) Designator Part Number Description LightOuput 0 15cd 30cd 75cd 95cd 110cd 177cd A B C D E F G H I J K L M N 0 P Q R S T U V W X Y SB4U SB4U-LF GSA-SBT SIGA-AB4G-LF INT-7ATW INT-8ATW EG1F-HD EG1F-VM EG1F-HDVM EGCF-VM EGCF-VMH EGCF-HDVM EGCF-HDVMH G4LFWF-H G4LFWF-HVM G4HFWF-S7VMC GCHFWF-S7VMC INT-4ASW XXXX DHF -24120C C01224T XXXX )(XXX XXXX XXXX Sounder Base for V Series Detectors 520Hz Sounder Base for V Series Detectors Sounder Base for PCOS Detectors 520Hz Sounder Base for PCOS Detectors WP Wall Mount Horn/Strobe WP Wall Mount Horn/Strobe Wall Mount Horn Wall Mount Strobe Wall Mount Horn/Strobe Ceiling Mount Strobe Ceiling Mount High Candela Strobe Ceiling Mount Horn/Strobe Ceiling Mount High Candela Horn/Strobe Wall Mount 520Hz Horn Wall Mount 520Hz Horn/Strobe Wall Mount Speaker/Strobe Ceiling Mount Speaker/Strobe Weatherproof Speaker/Strobe XXXX Magnetic Door Hold -Open Carbon Monoxide Detector XXXX XXXX )(XXX XXXX 28 92 52 92 180 90 22 85 127 245 285 102 135 160 246 309 94 140 273 325 333 551 111 152 281 333 324 554 166 219 266 381 437 78 101 188 245 94 140 273 325 551 159 15 75 Z N/A END OF CIRCUIT Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP18 Circuit: NAC1 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.47 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 34 14 3.07 103 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 18.1.1 P 110 0.245 34 20.093 0.307 0.0150 18.1.2 P 110 0.245 19 19.950 0.450 0.0220 18.1.3 P 110 0.245 23 19.812 0.588 0.0288 18.1.4 P 110 0.245 19 19.726 0.674 0.0330 18.1.5 P 110 0.245 22 19.660 0.740 0.0363 18.1.6 P 110 0.245 20 19.630 0.770 0.0378 END Z 0.000 0 19.630 0.770 0.0378 END Z 0.000 0 19.630 0.770 0.0378 END Z 0.000 0 19.630 0.770 0.0378 END Z 0.000 0 19.630 0.770 0.0378 END Z 0.000 0 19.630 0.770 0.0378 END Z 0.000 0 19.630 0.770 0.0378 END Z 0.000 0 19.630 0.770 0.0378 END Z 0.000 0 19.630 0.770 0.0378 END Z 0.000 0 19.630 0.770 0.0378 END Z 0.000 0 19.630 0.770 0.0378 END Z 0.000 0 19.630 0.770 0.0378 END Z 0.000 0 19.630 0.770 0.0378 END Z 0.000 0 19.630 0.770 0.0378 END Z 0.000 0 19.630 0.770 0.0378 END Z 0.000 0 19.630 0.770 0.0378 Totals: 1.47 137 CIRCUIT IS WITHIN LIMITS Percent Drop: 3.78% Current: 1.47 Point to Point Method Distance: End Line Voltage: 137 Voltage Drop: 0.77 of 19.63 CIRCUIT IS WITHIN LIMITS Percent Drop: 3.03% Current: 1.47 Load Centering Method Distance: 137 Voltage Drop: End of Line Voltage: 19.78 0.62 End of Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 6.06% Current: ', 1.47 137 19.16 Distance: Voltage Drop: End of Line Voltage: 1.24 PrOiect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP18 Circuit: NAC2 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0.592 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guage Ohms/ 1000' 5 14 3.07 219 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 18.2.1 P 30 0.101 5 20.382 0.018 0.0009 18.2.2 P 15 0.078 8 20.358 0.042 0.0021 18.2.3 P 30 0.101 29 20.284 0.116 0.0057 18.2.4 P 15 0.078 30 20.227 0.173 0.0085 18.2.5 P 15 0.078 52 20.152 0.248 0.0122 18.2.6 P 15 0.078 50 20.104 0.296 0.0145 18.2.7 P 15 0.078 50 20.080 0.320 0.0157 END Z 0.000 0 20.080 0.320 0.0157 END Z 0.000 0 20.080 0.320 0.0157 END Z 0.000 0 20.081) 0.320 0.0157 END Z 0.000 0 20.080 0.320 0.0157 END Z 0.000 0 20.080 0.320 0.0157 END Z 0.000 0 20.080 0.320 0.0157 END Z 0.000 0 20.080 0.320 0.0157 END Z 0.000 0 20.080 0.320 0.0157 END Z 0.000 0 20.080 0.320 0.0157 END Z 0.000 0 20.080 0.320 0.0157 END Z 0.000 0 20.080 0.320 0.0157 END Z 0.000 0 20.080 0.320 0.0157 END Z 0.000 0 20.080 0.320 0.0157 END Z 0.000 0 20.080 0.320 0.0157 Totals: 0.592 224 CIRCUIT IS WITHIN LIMITS Point to Point Method Percent Drop: 1.57% Current: 0.592 224 20.08 Distance: Voltage Drop: End of Line Voltage: 0.32 CIRCUIT IS WITHIN LIMITS Percent Drop: 2.00% Load Centering Method Current: 0.592 224 19.99 Distance: Voltage Drop: End of Line Voltage: 0.41 CIRCUIT IS WITHIN LIMITS Percent Drop: 3.99% Current: 0.592 End of Line Method 224 19.59 Distance: Voltage Drop: End of Line Voltage: 0.81 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP18 Circuit: NAC3 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.225 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 152 14 3.07 77 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 18.3.1 P 110 0.245 152 19.257 1.143 0.0560 18.3.2 P 110 0.245 19 19.142 1.258 0.0616 18.3.3 P 110 0.245 9 19.102 1.298 0.0636 18.3.4 P 110 0.245 40 18.981 1.419 0.0695 18.3.5 P 110 0.245 9 18.968 1.432 0.0702 END Z 0.000 0 18.968 1.432 0.0702 END Z 0.000 0 18.968 1.432 0.0702 END Z 0.000 0 18.968 1.432 0.0702 END Z 0.000 0 18.968 1.432 0.0702 END Z 0.000 0 18.968 1.432 0.0702 END Z 0.000 0 18.968 1.432 0.0702 END Z 0.000 0 18.968 1.432 0.0702 END Z 0.000 0 18.968 1.432 0.0702 END Z 0.000 0 18.968 1.432 0.0702 END Z 0.000 0 18.968 1.432 0.0702 END Z 0.000 0 18.968 1.432 0.0702 END Z 0.000 0 18.968 1.432 0.0702 END Z 0.000 0 18.968 1.432 0.0702 END Z 0.000 0 18.968 1.432 0.0702 END Z 0.000 0 18.968 1.432 0.0702 END Z 0.000 0 18.968 1.432 0.0702 Totals: 1.225 229 CIRCUIT IS WITHIN LIMITS Percent Drop: 7.02% Current: 1.225 Point to Point Method Distance: End Line Voltage: 229 Voltage Drop: 1.43 of 18.97 CIRCUIT IS WITHIN LIMITS Load Centering Method Percent Drop: 4.22% Current: 1.225 229 Distance: End Line Voltage: Voltage Drop: 0.86 of 19.54 End of Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 8.44% Current: 1.225 229 Distance: Voltage Drop: End of Line Voltage: 18.68 1.72 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP18 Circuit: NAC4 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.012 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 33 14 3.07 212 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 18.4.1 D 0.092 33 20.195 0.205 0.0101 18.4.2 D 0.092 19 20.088 0.312 0.0153 18.4.3 D 0.092 22 19.976 0.424 0.0208 18.4.4 D 0.092 19 19.890 0.510 0.0250 18.4.5 D 0.092 22 19.803 0.597 0.0293 18.4.6 D 0.092 20 19.735 0.665 0.0326 18.4.7 D 0.092 19 19.681 0.719 0.0352 18.4.8 D 0.092 22 19.632 0.768 0.0377 18.4.9 D 0.092 22 19.594 0.806 0.0395 18.4.10 D 0.092 27 _ 19.564 0.836 0.0410 18.4.11 D 0.092 20 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 Totals: 1.012 245 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 4.15% Current: 1.012 Distance: 245 Voltage Drop: End of Line Voltage: 19.55 0.85 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 3.73% Current: 1.012 245 19.64 Distance: Voltage Drop: End of Line Voltage: 0.76 End Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 7.46% Current: 1.012 of Distance: 245 Voltage Drop: End of Line Voltage: 18.88 1.52 Prosect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP18 Battery Calculations Standy Circuit / Device Current Alarm Current Qty Total Standy Current Total Alarm Current Power Supply 70 70 1 - 70 70 NAC Power NAC1 0 1470 1 0 1470 NAC2 0 592 1 0 592 NAC3 0 1225 1 0 1225 NAC4 66 1012 1 66 0 200 mA Aux Power Aux 0 0 0 0 0 Aux 0 0 0 0 0 Aux 0 0 0 0 0 TOTALS: 136 3357 Total Standy Current (Amps): 0.136 X 24 Hours: 3.264 Amphours in Standy Total Alarm Current (Amps): 3.357 X 15 Mins: 0.84 Amphours in Alarm 4.10 Required Amphours +20% Safety Total Required Amphours: 4.10 Margin 4'92 hours Amphours (2) 12V 8Ah Batteries Required. *Magnetic Door Holders are not included in the battery calculations. Power to these devices will be automatically disconnected upon loss of NC power to reduce battery size. DEVICE LEGEND Devices Current (Milliamps) Designator Part Number Description Light0uput 0 15cd 30cd 75cd 95cd 110cd 177cd A B C D E F G H J K L M N 0 P Q R S T U V W X Y SB4U SB4U-LF GSA-SBT SIGA-AB4G-LF INT-7ATW INT-8ATW EG1F-HD EG1F-VM EG1F-HDVM EGCF-VM EGCF-VMH EGCF-HDVM EGCF-HDVMH G4LFWF-H G4LFWF-HVM G4HFWF-S7VMC GCHFWF-S7VMC INT-4ASW XXXX DHF-24120C CO1224T XXXX XXXX XXXX XXXX Sounder Base for V Series Detectors 520Hz Sounder Base for V Series Detectors Sounder Base for PCOS Detectors 520Hz Sounder Base for PCOS Detectors WP Wall Mount Horn/Strobe WP Wall Mount Horn/Strobe Wall Mount Horn Wall Mount Strobe Wall Mount Horn/Strobe Ceiling Mount Strobe Ceiling Mount High Candela Strobe Ceiling Mount Horn/Strobe Ceiling Mount High Candela Horn/Strobe Wall Mount 520Hz Horn Wall Mount 520Hz Horn/Strobe Wall Mount Speaker/Strobe Ceiling Mount Speaker/Strobe Weatherproof Speaker/Strobe XXXX Magnetic Door Hold-Open Carbon Monoxide Detector XXXX XXXX XXXX XXXX 28 92 52 92 180 90 22 85 127 135 245 285 309 102 160 246 94 140 273 325 333 551 111 152 281 333 324 554 166 219 266 381 437 78 101 188 245 94 140 273 325 551 159 15 75 Z N/A END OF CIRCUIT Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP19 Circuit: NAC1 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.225 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms / 1000' 12 14 3.07 88 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 19.1.1 P 110 0.245 12 20.310 0.090 0.0044 19.1.2 P 110 0.245 25 20.159 0.241 0.0118 19.1.3 P 110 0.245 23 20.056 0.344 0.0169 19.1.4 P 110 0.245 9 20.028 0.372 0.0182 19.1.5 P 110 0.245 31 19.982 0.418 0.0205 END Z 0.000 0 19.982 0.418 0.0205 END Z 0.000 0 19.982 0.418 0.0205 END Z 0.000 0 19.982 0.418 0.0205 END Z 0.000 0 19.982 0.418 0.0205 END Z 0.000 0 19.982 0.418 0.0205 END Z 0.000 0 19.982 0.418 0.0205 END Z 0.000 0 19.982 0.418 0.0205 END Z 0.000 0 19.982 0.418 0.0205 END Z 0.000 0 19.982 0.418 0.0205 END Z 0.000 0 19.982 0.418 0.0205 END Z 0.000 0 19.982 0.418 0.0205 END Z 0.000 0 19.982 0.418 0.0205 END Z 0.000 0 19.982 0.418 0.0205 END Z 0.000 0 19.982 0.418 0.0205 END Z 0.000 0 19.982 0.418 0.0205 END Z 0.000 0 19.982 0.418 0.0205 Totals: 1.225 100 CIRCUIT IS WITHIN LIMITS Percent Drop: 2.05% Current: 1.225 Point to Point Method Distance: End Line 100 Voltage Drop: 0.42 of Voltage: 19.98 CIRCUIT IS WITHIN LIMITS Percent Drop: 1.84% Load Centering Method Current: 1.225 100 20.02 Distance: Voltage Drop: End of Line Voltage: 0.38 End of Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 3.69% Current: 1.225 100 19.65 Distance: Voltage Drop: End of Line Voltage: 0.75 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP19 Circuit: NAC2 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.47 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 102 14 3.07 115 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 19.2.1 P 110 0.245 102 19.479 0.921 0.0451 19.2.2 P 110 0.245 21 19.321 1.079 0.0529 19.2.3 P 110 0.245 22 19.189 1.211 0.0594 19.2.4 P 110 0.245 32 19.045 1.355 0.0664 19.2.5 P 110 0.245 16 18.996 1.404 0.0688 19.2.6 P 110 0.245 24 18.960 1.440 0.0706 END Z 0.000 0 18.960 1.440 0.0706 END Z 0.000 0 18.960 1.440 0.0706 END Z 0.000 0 18.960 1.440 0.0706 END Z 0.000 0 18.960 1.440 0.0706 END Z 0.000 0 18.960 1.440 0.0706 END Z 0.000 0 18.960 1.440 0.0706 END Z 0.000 0 18.960 1.440 0.0706 END Z 0.000 0 18.960 1.440 0.0706 END Z 0.000 0 18.960 1.440 0.0706 END Z 0.000 0 18.960 1.440 0.0706 END Z 0.000 0 18.960 1.440 0.0706 END Z 0.000 0 18.960 1.440 0.0706 END Z 0.000 0 18.960 1.440 0.0706 END Z 0.000 0 18.960 1.440 0.0706 END Z 0,000 0 18.960 1.440 0.0706 Totals: 1.47 217 CIRCUIT IS WITHIN LIMITS Percent Drop: 7.06% Current: 1.47 Point to Point Method 217 18.96 Distance: Voltage Drop: End of Line Voltage: 1.44 CIRCUIT IS WITHIN LIMITS Percent Drop: 4.80% Load Centering Method Current: 1.47 217 19.42 Distance: Voltage Drop: End of Line Voltage: 0.98 CIRCUIT IS WITHIN LIMITS Percent Drop: 9.60% Current: Distance: 1.47 End of Line Method 217 Voltage Drop: 1.96 End of Line Voltage: 18.44 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP19 Circuit: NAC3 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Ohms / Cuaae 1000' 0 14 3.07 0 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 Totals: 0 0 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 Point to Point Method Distance: End Line Voltage: 0 20.40 Voltage Drop: 0.00 of Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 0 20.40 Distance: Voltage Drop: End of Line Voltage: 0.00 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 End of Line Method Distance: 0 Voltage Drop: End of Line Voltage: 20.40 0.00 Proiect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP19 Circuit: NAC4 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.012 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 16 14 3.07 229 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 19.4.1 D 0.092 16 20.301 0.099 0.0049 19.4.2 D 0.092 17 20.205 0.195 0.0096 19.4.3 D 0.092 24 20.083 0.317 0.0156 19.4.4 D 0.092 21 19.988 0.412 0.0202 19.4.5 D 0.092 16 19.924 0.476 0.0233 19.4.6 D 0.092 27 19.833 0.567 0.0278 19.4.7 D 0.092 24 19.765 0.635 0.0311 19.4.8 D 0.092 23 19.713 0.687 0.0337 19.4.9 D 0.092 27 19.667 0.733 0.0359 19.4.10 D 0.092 24 19.640 0.760 0.0372 19.4.11 D 0.092 26 19.626 0.774 0.0380 END Z 0.000 0 19.626 0.774 0.0380 END Z 0.000 0 19.626 0.774 0.0380 END Z 0.000 0 19.626 0.774 0.0380 END Z 0.000 0 19.626 0.774 0.0380 END Z 0.000 0 19.626 0.774 0.0380 END Z 0.000 0 19.626 0.774 0.0380 END Z 0.000 0 19.626 0.774 0.0380 END Z 0.000 0 19.626 0.774 0.0380 END Z 0.000 0 19.626 0.774 0.0380 END Z 0.000 0 19.626 0.774 0.0380 Totals: 1.012 245 CIRCUIT IS WITHIN LIMITS Point to Point Method Percent Drop: 3.80% Current: 1.012 Distance: 245 Voltage Drop: End of Line Voltage: 19.63 0.77 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 3.73% Current: 1.012 245 19.64 Distance: Voltage Drop: End of Line Voltage: 0.76 End Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 7.46% Current: 1.012 of Distance: 245 Voltage Drop: End of Line Voltage: 18.88 1.52 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP19 Battery Calculations Standy Circuit / Device Current Alarm Current Qty Total Standy Current Total Alarm Current Power Supply 70 70 1 70 70 NAC Power NAC1 0 1225 1 0 1225 NAC2 0 1470 1 0 1470 NAC3 0 0 0 0 0 NAC4 66 1012 1 66 0 200 mA Aux Power Aux 0 0 0 0 0 Aux 0 0 0 0 0 Aux 0 0 0 0 0 TOTALS: 136 2765 Total Standy Current (Amps): 0.136 X 24 Hours: 3.264 Amphours in Standy Total Alarm Current (Amps): 2.765 X 15 Mins: 0.69 Amphours in Alarm 3.96 Required Amphours Required Amphours: +20% Safety 3.96 4'75 Tota! Margin Am hours p (2) 1 2V 8Ah Batteries Required. "Magnetic Door Holders are not included in the battery calculations. Power to these devices will be automatically disconnected upon loss of A/C power to reduce battery size. DEVICE LEGEND Devices Current (Milliamps) Designator Part Number Description Light Ouput 0 15cd 30cd 75cd 95cd 110cd 177cd A B C D E F G H I J K L M N 0 P ,. Q ' R S T U V W X Y SB4U SB4U-LF GSA-SBT SIGA-AB4G-LF INT-7ATW INT-8ATW EG1F-HD EG1F-VM EG1F-HDVM EGCF-VM EGCF-VMH EGCF-HDVM EGCF-HDVMH G4LFWF-H G4LFWF-HVM G4HFWF-S7VMC GCHFWF-S7VMC INT-4ASW XXXX DHF-24120C C01224T XXXX XXXX XXXX XXXX Sounder Base for V Series Detectors 520Hz Sounder Base for V Series Detectors Sounder Base for PCOS Detectors 520Hz Sounder Base for PCOS Detectors WP Wall Mount Horn/Strobe WP Wall Mount Horn/Strobe Wall Mount Horn Wall Mount Strobe Wall Mount Horn/Strobe Ceiling Mount Strobe Ceiling Mount High Candela Strobe Ceiling Mount Horn/Strobe Ceiling Mount High Candela Horn/Strobe Wall Mount 520Hz Horn Wall Mount 520Hz Horn/Strobe Wall Mount Speaker/Strobe Ceiling Mount Speaker/Strobe Weatherproof Speaker/Strobe XXXX Magnetic Door Hold-Open Carbon Monoxide Detector XXXX XXXX XXXX XXXX 28 92 52 92 180 90 22 85 102 127 135 245 160 285 246 309 94 140 273 325 333 551 111 152 281 333 324 554 166 219 266 381 437 78 101 188 245 94 140 273 325 551 159 15 75 Z N/A END OF CIRCUIT Reliance Electric 4795 Oakland Street, Denver, CO 80239 (720) 749-2850 element BY WEST I N 515 Industry Drive Tukwila, WA 98188 Kidde Vigilant Voltage Drop / Battery Calculations Proiect: Tukwila Element Panel Type: vM-1S Panel Name: FACP1 Circuit: NAC1 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms / 1000' 0 14 3.07 0 14 3.07 Low Frequency Device Device Address Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0,000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20,400 0.000 0.0000 Totals: 0 0 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Point to Point Method Current:) 0 Distance: 0 End of Line Voltage: 20.40 Voltage Drop: 0.00 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 Distance: 0 20.40 End of Line Voltage: Voltage Drop:, 0.00 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 End of Line Method Distance: 0 20.40 End of Line Voltage: Voltage Drop: 0.00 Protect: Tukwila Element Panel Type: VM -1S Panel Name: FACP1 Circuit: NAC2 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 0 14 3.07 0 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 T+140:Q42otals: 0 0 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Point to Point Method Current: 0 0 20.40 Distance: Voltage Drop: End of Line Voltage: 0.00 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Load Centering Method Current: 0 0 20.40 Distance: Voltage Drop: End of Line Voltage: 0.00 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% End of Line Method Current: 0 0 20.40 Distance: Voltage Drop: End of Line Voltage: 0.00 Project: Tukwila Element Panel Type: VM -1S Panel Name: FACP1 Circuit: NAC3 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guaae Ohms/ 1000' 0 14 3.07 0 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 Totals: 0 0 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Point to Point Method Current: 0 Distance: Voltage Drop: 0 End of Line Voltage: 20.40 0.00 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Load Centering Method Current: 0 Distance: Voltage Drop: 0 End of Line Voltage: 20.40 0.00 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% End of Line Method Current: 0 Distance: Voltage Drop: 0 End of Line Voltage: 20.40 0.00 Proiect: Tukwila Element Panel Type: VM -1S Panel Name: FACP1 Circuit: NAC4 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0 Distance to 1st Device: Remaining Distance: Amps System Type: 0 Wire Ohms / Guage 1000' 3.07 3.07 14 0 14 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 Totals: 0 0 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 Point to Point Method 0 20.40 Distance: Voltage Drop: End of Line Voltage: 0.00 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 Load Centering Method 0 Distance: Voltage Drop: End of Line Voltage: 20.40 0.00 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 End of Line Method 0 20.40 Distance: Voltage Drop: End of Line Voltage: 0.00 Prosect: Tukwila Element Panel Type: vM-1S Panel Name: FACP1 Battery Calculations Standy Alarm Total Standy Total Alarm Circuit / Device Current Current Qty Current Current Base Panel 381 481 1 381 481 VM -SLC* 120 132 3 360 396 VM-ETH1 42 54 1 42 54 VM-MFK 37 39 1 37 39 VM-NOC 98 98 1 98 98 VM -PMI 23 29 1 23 29 0 0 0 0 0 0 0 0 0 0 0 0 NAC Power NAC1 0 0 1 0 0 NAC2 0 0 1 0 0 NAC3 0 0 1 0 0 NAC4 0 0 1 0 0 TOTALS: 941 1097 otal Standby Current (Amps): 0.941 X 24 Hours 22.58 Amphours in Standby Total Alarm Current (Amps): 1.097 X 15 Mins: 0.27 Amphours in Alarm 22.86 Required Amphours Required Amphours: +20% Safety 22.86 27'43 Total Margin Am hours p (2) 12V 28Ah Batteries Required. * VM -SLC is calculated at 100% capacity. (125 detectors & 125 modules per loop) DEVICE LEGEND Devices Current (Milliamps) Designator Part Number Description Light Ouput 0 15cd 30cd 75cd 95cd 110cd 177cd A B C D E F G H 1 J K L M N 0 P Q R S T U V W X Y SB4U SB4U-LF GSA-SBT SIGA-AB4G-LF INT-7ATW INT-8ATW EG1F-HD EG1 F-VM EG1F-HDVM EGCF-VM EGCF-VMH EGCF-HDVM EGCF-HDVMH G4LFWF-H G4LFWF-HVM G4HFWF-S7VMC GCHFWF-S7VMC INT-4ASW XXXX DHF-24120C CO1224T XXXX XXXX XXXX XXXX Sounder Base for V Series Detectors 520Hz Sounder Base for V Series Detectors Sounder Base for PCOS Detectors 520Hz Sounder Base for PCOS Detectors WP Wall Mount Horn/Strobe WP Wall Mount Horn/Strobe Wall Mount Horn Wall Mount Strobe Wall Mount Horn/Strobe Ceiling Mount Strobe Ceiling Mount High Candela Strobe Ceiling Mount Horn/Strobe Ceiling Mount High Candela Horn/Strobe Wall Mount 520Hz Horn Wall Mount 520Hz Horn/Strobe Wall Mount Speaker/Strobe Ceiling Mount Speaker/Strobe Weatherproof Speaker/Strobe XXXX Magnetic Door Hold-Open Carbon Monoxide Detector XXXX XXXX XXXX XXXX 28 92 52 92 180 90 22 85 127 245 246 285 1 309 102 135 160 94 140 273 325 333 551 111 152 281 333 324 554 166 219 266 381 437 78 101 188 245 94 140 273 325 551 159 15 75 Z N/A END OF CIRCUIT Project: Tukwila Element Panel Type: vM-1 s Panel Name: FACP2 Circuit: NAC1 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guage Ohms/ 1000' 0 14 3.07 0 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 Totals: 0 0 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current:1 0 Distance: 0 End Line Voltage: 20.40 Voltage Drop: 0.00 of CIRCUIT IS WITHIN LIMITS Load Centering Method Percent Drop: 0.00% Current:' 0 Distance: I 0 End Line Voltage: 20.40 Voltage Drop: 0.00 of End Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current:1 0 of Distance: 0 End Line Voltage: 20.40 Voltage Drop: 0.00 of Project: Tukwila Element Panel Type: VM -1S Panel Name: FACP2 Circuit: NAC2 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 0 14 3.07 0 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 T+140:Q42otals: 0 0 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 Point to Point Method 0 20.40 Distance: Voltage Drop: End of Line Voltage: 0.00 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Load Centering Method Current: 0 0 20.40 Distance: Voltage Drop: End of Line Voltage: 0.00 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% End Line Method Current: 0 of Distance: 0 Voltage Drop: End of Line Voltage: 20.40 0.00 Project: Tukwila Element Panel Type: vM-1s Panel Name: FACP2 Circuit: NAC3 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guaae Ohms/ 1000' 0 14 3.07 0 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 Totals: 0 0 Point to Point Method CIRCUIT IS WITHIN LIM TS Percent Drop: 0.00% Current: 0 Distance: 0 End Voltage Drop: 0.00 of Line Voltage: 20.40 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Load Centering Method Current: 0 Distance: Voltage Drop: 0 End of Line Voltage: 20.40 0.00 End of Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 Distance: 0 End Line Voltage: Voltage Drop: 0.00 of 20.40 Project: Tukwila Element Panel Type: VM -1S Panel Name: FACP2 Circuit: NAC4 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guage Ohms/ 1000' 3.07 3.07 0 14 0 14 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 Totals: 0 0 CIRCUIT IS WITHIN LIMITS Point to Point Method Percent Drop: 0.00% Current: 0 Distance: 0 Voltage Drop: End of Line Voltage: 20.40 0.00 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 Load Centering Method 0 20.40 Distance: Voltage Drop: End of Line Voltage: 0.00 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 End of Line Method 0 20.40 Distance: Voltage Drop: End of Line Voltage: 0.00 Prosect: Tukwila Element Panel Type: vM-1 s Panel Name: FACP2 Battery Calculations Standy Alarm Total Standy Total Alarm Circuit / Device Current Current Qty Current Current Base Panel 381 481 1 381 481 VM -SLC" 120 132 2 240 264 VM-NOC 98 98 1 98 98 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 NAC Power NAC1 0 0 1 0 0 NAC2 0 0 1 0 0 NAC3 0 0 1 0 0 NAC4 0 0 1 0 0 TOTALS: 719 843 Total Standby Current (Amps): 0.719 X 24 Hours 17.26 Amphours in Standby Total Alarm Current (Amps): 0.843 X 15 Mins: 0.21 Amphours in Alarm 17.47 Required Amphours +20% Safety Total Required Amphours: 17.47 Margin 20'96 hours Amphours (2) 12V 26Ah Batteries Required. * VM -SLC is calculated at 100% capacity. (125 detectors & 125 modules per loop) DEVICE LEGEND Devices Current (Milliamps) Designator Part Number Description Light Ouput 0 15cd 30cd 75cd 95cd 110cd 177cd A B C D E F G H J K L M N 0 P Q R S T U V W X Y SB4U SB4U-LF GSA-SBT SIGA-AB4G-LF INT-7ATW INT-8ATW EG1F-HD EG1F-VM EG1F-HDVM EGCF-VM EGCF-VMH EGCF-HDVM EGCF-HDVMH G4LFWF-H G4LFWF-HVM G4HFWF-S7VMC GCHFWF-S7VMC INT-4ASW XXXX DHF -24120C C01224T XXXX XXXX XXXX XXXX Sounder Base for V Series Detectors 520Hz Sounder Base for V Series Detectors Sounder Base for PCOS Detectors 520Hz Sounder Base for PCOS Detectors WP Wall Mount Horn/Strobe WP Wall Mount Horn/Strobe Wall Mount Horn Wall Mount Strobe Wall Mount Horn/Strobe Ceiling Mount Strobe Ceiling Mount High Candela Strobe Ceiling Mount Horn/Strobe Ceiling Mount High Candela Horn/Strobe Wall Mount 520Hz Horn Wall Mount 520Hz Horn/Strobe Wall Mount Speaker/Strobe Ceiling Mount Speaker/Strobe Weatherproof Speaker/Strobe XXXX Magnetic Door Hold -Open Carbon Monoxide Detector XXXX XXXX XXXX XXXX 28 92 52 92 180 90 22 85 102 127 135 245 160 246 285 309 94 140 273 325 333 551 111 152 281 333 324 554 166 219 266 381 437 78 101 188 245 94 140 273 325 551 159 15 75 Z N/A END OF CIRCUIT Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP1 Circuit: NAC1 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.659 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 33 14 3.07 284 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 1.1.1 Q 30 0.140 33 20.064 0.336 0.0165 1.1.2 P 15 0.078 22 19.859 0.541 0.0265 1.1.3 P 15 0.078 17 19.708 0.692 0.0339 1.1.4 P 15 0.078 11 19.616 0.784 0.0384 1.1.5 P 15 0.078 6 19.569 0.831 0.0407 1.1.6 P 15 0.078 20 19.421 0,979 0.0480 1.1.7 P 30 0.101 19 19.289 1.111 0.0545 1.1.8 Q 30 0.140 29 19.106 1.294 0.0634 1.1.9 Q 30 0.140 17 19.013 1.387 0.0680 1.1.10 Q 15 0.094 31 18.871 1.529 0.0750 1.1.11 Q 15 0.094 17 18.803 1.597 0.0783 1.1.12 Q 30 0.140 19 18.737 1.663 0.0815 1.1.13 Q 30 0.140 18 18.691 1.709 0.0838 1.1.14 Q 30 0.140 35 18.631 1.769 0.0867 1.1.15 Q 30 0.140 23 18.611 1.789 0.0877 END Z 0.000 0 18.611 1.789 0.0877 END Z 0.000 0 18.611 1.789 0.0877 END Z 0.000 0 18.611 1.789 0.0877 END Z 0.000 0 18.611 1.789 0.0877 END Z 0.000 0 18.611 1.789 0.0877 END Z 0.000 0 18.611 1.789 0.0877 Totals: 1.659 317 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 8.77% Current: 1.659 Distance: 317 End Line Voltage: 18.61 Voltage Drop: 1.79 of Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 7.91% Current: 1.659 317 18.79 Distance: Voltage Drop: End of Line Voltage: 1.61 End Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 15.83% Current: 1.659 of Distance: 317 Volta 9 a Dro p:' End of Line Voltage: 17.17 3.23 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP1 Circuit: NAC2 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.675 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 75 14 3.07 304 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 1.2.1 P 15 0.078 75 19.629 0.771 0.0378 1.2.2 Q 30 0.140 30 19.334 1.066 0.0522 1.2.3 P 15 0.078 31 19.057 1.343 0.0658 1.2.4 Q 75 0.273 25 18.845 1.555 0.0762 1.2.5 Q 30 0.140 43 18.553 1.847 0.0905 1.2.6 Q 75 0.273 38 18.328 2.072 0.1016 1.2.7 P 15 0.078 20 18.243 2.157 0.1057 1.2.8 P 15 0.078 30 18.130 2.270 0.1113 1.2.9 J 30 0.140 13 18.087 2.313 0.1134 1.2.10 J 30 0.140 16 18.048 2.352 0.1153 1.2.11 P 15 0.078 14 18.026 2.374 0.1164 1.2.12 P 15 0.078 17 18.007 2.393 0.1173 1.2.13 P 30 0.101 27 17.990 2.410 0.1181 END Z 0.000 0 17.990 2.410 0.1181 END Z 0.000 0 17.990 2.410 0.1181 END Z 0.000 0 17.990 2.410 0.1181 END Z 0.000 0 17.990 2.410 0.1181 END Z 0.000 0 17.990 2.410 0.1181 END Z 0.000 0 17.990 2.410 0.1181 END Z 0.000 0 17.990 2.410 0.1181 END Z 0.000 0 17.990 2.410 0.1181 T+140:Q42otals: 1.675 379 CIRCUIT IS WITHIN LIMITS Percent Drop: 11.81% Point to Point Method Current: 1.675 Distance: 379 End Line Voltage: 17.99 Voltage Drop: 2.41 of CIRCUIT IS WITHIN LIMITS Percent Drop: 9.55% Load Centering Method Current: 1.675 379 18.45 Distance: Voltage Drop: End of Line Voltage: 1.95 CIRCUIT IS WITHIN LIMITS Percent Drop: 19.11% Current: 1.675 End of Line Method 379 16.50 Distance: Voltage Drop: End of Line Voltage: 3.90 Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP1 Circuit: NAC3 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.773 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guaae Ohms/ 1000' 11 14 3.07 265 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 1.3.1 P 30 0.101 11 20.280 0.120 0.0059 1.3.2 Q 30 0.140 38 19.890 0.510 0.0250 1.3.3 H 15 0.085 28 19.627 0.773 0.0379 1.3.4 P 30 0.101 12 19.520 0.880 0.0431 1.3.5 Q 75 0.273 28 19.289 1.111 0.0545 1.3.6 Q 75 0.273 14 19.197 1.203 0.0590 1.3.7 P 15 0.078 30 19.049 1.351 0.0662 1.3.8 P 15 0.078 11 19.000 1.400 0.0686 1.3.9 H 15 0.085 22 18.913 1.487 0.0729 1.3.10 R 75 0.159 7 18.889 1.511 0.0741 1.3.11 R 75 0.159 41 18.789 1.611 0.0790 1.3.12 Q 30 0.140 23 18.755 1.645 0.0807 1.3.13 P 30 0.101 11 18.748 1.652 0.0810 END Z 0.000 0 18.748 1.652 0.0810 END Z 0.000 0 18.748 1.652 0.0810 END Z 0.000 0 18.748 1.652 0.0810 END Z 0.000 0 18.748 1.652 0.0810 END Z 0.000 0 18.748 1.652 0.0810 END Z 0.000 0 18.748 1.652 0.0810 END Z 0.000 0 18.748 1.652 0.0810 END Z 0.000 0 18.748 1.652 0.0810 Totals: 1.773 276 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 8.10% Current: 1.773 Distance: 276 Voltage Drop: End of Line Voltage: 18.75 1.65 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 7.36% Current: 1.773 276 18.90 Distance: End Line Voltage: Voltage Drop: 1.50 of End of Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 14.73% Current: 1.773 276 17.40 Distance: End Line Voltage: Voltage Drop: 3.00 of Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP1 Circuit: NAC4 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Ohms / �uaae 1000' 0 14 3.07 0 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop END END END END END END END END END END END END END END END END END END END END END Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Totals: 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0 0 20.400 0.000 20.400 0.000 20.400 0.000 20.400 0.000 20.400 0.000 20.400 0.000 20.400 0.000 20.400 0.000 20.400 0.000 20.400 0.000 20.400 0.000 20.400 0.000 20.400 0.000 20.400 0.000 20.400 0.000 20.400 0.000 20.400 0.000 20.400 0.000 20.400 0.000 20.400 0.000 20.400 0.000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: End of Line Voltage: 0.00% Current: Distance: Voltage Drop: 0 0 20.40 0.00 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: End of Line Voltage: 0.00% Current: Distance: Voltage Drop: 0 0 20.40 0.00 End of Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: End of Line Voltage: 0.00% Current: Distance: Voltage Drop: 0 0 20.40 0.00 Prosect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP1 Battery Calculations Standy Circuit / Device Current Alarm Current Qty Total Standy Current Total Alarm Current Power Supply 70 70 1 70 70 NAC Power NAC1 0 1659 1 0 1659 NAC2 0 1675 1 0 1675 NAC3 0 1773 1 0 1773 NAC4 0 0 0 0 0 200 mA Aux Power Aux 0 0 0 0 0 Aux 0 0 0 0 0 Aux 0 0 0 0 0 TOTALS: 70 5177 Total Standy Current (Amps): 0.07 X 24 Hours: 1.68 Amphours in Standy Total Alarm Current (Amps): 5.177 X 15 Mins: 1.29 Amphours in Alarm 2.97 Required Amphours Required Amphours: +20% Safety 2.97 3'57 Total Margin Am hours p (2) 12V 8Ah Batteries Required. *Magnetic Door Holders are not included in the battery calculations. Power to these devices will be automatically disconnected upon loss of NC power to reduce battery size. DEVICE LEGEND Devices Current (Milliamps) Designator Part Number Description Light Ouput 0 15cd 30cd 75cd 95cd 110cd 177cd A B C D E F G H I J K L M N 0 P Q R S T U V W X Y SB4U SB4U-LF GSA-SBT SIGA-AB4G-LF INT-7ATW INT-8ATW EG1F-HD EG1F-VM EG1F-HDVM EGCF-VM EGCF-VMH EGCF-HDVM EGCF-HDVMH G4LFWF-H G4LFWF-HVM G4HFWF-S7VMC GCHFWF-S7VMC INT-4ASW XXXX DHF-24120C CO1224T XXXX XXXX XXXX XXXX Sounder Base for V Series Detectors 520Hz Sounder Base for V Series Detectors Sounder Base for PCOS Detectors 520Hz Sounder Base for PCOS Detectors WP Wall Mount Horn/Strobe WP Wall Mount Horn/Strobe Wall Mount Horn Wall Mount Strobe Wall Mount Horn/Strobe Ceiling Mount Strobe Ceiling Mount High Candela Strobe Ceiling Mount Horn/Strobe Ceiling Mount High Candela Horn/Strobe Wall Mount 520Hz Horn Wall Mount 520Hz Horn/Strobe Wall Mount Speaker/Strobe Ceiling Mount Speaker/Strobe Weatherproof Speaker/Strobe XXXX Magnetic Door Hold-Open Carbon Monoxide Detector XXXX XXXX XXXX XXXX 28 92 52 92 180 90 22 85 127 245 285 102 135 160 246 309 94 140 273 325 333 551 111 152 281 333 324 554 166 219 266 381 437 78 101 188 245 94 140 273 325 551 159 15 75 Z N/A END OF CIRCUIT Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP2 Circuit: NAC1 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0.82 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 140 14 3.07 65 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 2.1.1 P 110 0.245 140 19.695 0.705 0.0346 2.1.2 P 110 0.245 19 19.628 0.772 0.0378 2.1.3 H 15 0.085 10 19.608 0.792 0.0388 2.1.4 P 110 0.245 36 19.554 0.846 0.0415 END Z 0.000 0 19.554 0.846 0.0415 END Z 0.000 0 19.554 0.846 0.0415 END Z 0.000 0 19.554 0.846 0.0415 END Z 0.000 0 19.554 0.846 0.0415 END Z 0.000 0 19.554 0.846 0.0415 END Z 0.000 0 19.554 0.846 0.0415 END Z 0.000 0 19.554 0.846 0.0415 END Z 0.000 0 19.554 0.846 0.0415 END Z 0.000 0 19.554 0.846 0.0415 END Z 0.000 0 19.554 0.846 0.0415 END Z 0.000 0 19.554 0.846 0.0415 END Z 0.000 0 19.554 0.846 0.0415 END Z 0.000 0 19.554 0.846 0.0415 END Z 0.000 0 19.554 0.846 0.0415 END Z 0.000 0 19.554 0.846 0.0415 END Z 0.000 0 19.554 0.846 0.0415 END Z 0.000 0 19.554 0.846 0.0415 Totals: 0.82 205 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 4.15% Current: 0.82 Distance:, 205 End Line Voltage: Voltage Drop: 0.85 of 19.55 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 2.53% Current: ! 0.82 Distance: 205 19.88 End of Line Voltage: Voltage Drop: 0.52 End Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 5.06% Current: 0.82 of Distance: 205 End Line Voltage: Voltage Drop:; 1.03 of 19.37 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP2 Circuit: NAC2 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 0 14 3.07 0 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop END Z 0.000 0 I 20.400 0.000 0.0000 END Z 0.000 0 I 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 T+140:Q42otals: 0 0 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Point to Point Method Current: 0 0 20.40 Distance: Voltage Drop: End of Line Voltage: 0.00 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Load Centering Method Current: 0 0 20.40 Distance: Voltage Drop: End of Line Voltage: 0.00 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% End of Line Method Current: 0 0 20.40 Distance: Voltage Drop: End of Line Voltage: 0.00 Prosect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP2 Circuit: NAC3 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.555 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guaae Ohms/ 1000' 11 14 3.07 129 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 2.3.1 P 110 0.245 11 20.295 0.105 0.0051 2.3.2 P 110 0.245 9 20.223 0.177 0.0087 2.3.3 P 110 0.245 34 20.000 0.400 0.0196 2.3.4 P 110 0.245 23 19.884 0.516 0.0253 2.3.5 P 110 0.245 25 19.796 0.604 0.0296 2.3.6 P 110 0.245 24 19.748 0.652 0.0320 2.3.7 H 15 0.085 14 19.740 0.660 0.0323 END Z 0.000 0 19.740 0.660 0.0323 END Z 0.000 0 19.740 0.660 0.0323 END Z 0.000 0 19.740 0.660 0.0323 END Z 0.000 0 19.740 0.660 0.0323 END Z 0.000 0 19.740 0.660 0.0323 END Z 0.000 0 19.740 0.660 0.0323 END Z 0.000 0 19.740 0.660 0.0323 END Z 0.000 0 19.740 0.660 0.0323 END Z 0.000 0 19.740 0.660 0.0323 END Z 0.000 0 19.740 0.660 0.0323 END Z 0.000 0 19.740 0.660 0.0323 END Z 0.000 0 19.740 0.660 0.0323 END Z 0.000 0 19.740 0.660 0.0323 END Z 0.000 0 19.740 0.660 0.0323 Totals: 1.555 140 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 3.23% Current: 1.555 Distance: 140 Voltage Drop: End of Line Voltage: 19.74 0.66 Load Centering Method CIRCUIT IS WITHIN LIMITSI Percent Drop: 3.28% Current: 1.555 140 19.73 Distance: Voltage Drop: End of Line Voltage: 0.67 CIRCUIT IS WITHIN LIMITS Percent Drop: 6.55% End of Line Method Current: 1.555 140 19.06 Distance: Voltage Drop: End of Line Voltage: 1.34 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP2 Circuit: NAC4 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0.828 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guage Ohmsi 1000' 7 14 3.07 195 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 2.4.1 D 0.092 7 20.364 0.036 0.0017 2.4.2 D 0.092 20 20.274 0.126 0.0062 2.4.3 D 0.092 15 20.215 0.185 0.0091 2.4.4 D 0.092 30 20.113 0.287 0.0141 2.4.5 D 0.092 17 20.065 0.335 0.0164 2.4.6 D 0.092 26 20.006 0.394 0.0193 2.4.7 D 0.092 32 19.952 0.448 0.0220 2.4.8 D 0.092 27 19.922 0.478 0.0235 2.4.9 D 0.092 28 19.906 0.494 0.0242 END Z 0.000 0 19.906 0.494 0.0242 END Z 0.000 0 19.906 0.494 0.0242 END Z 0.000 0 19.906 0.494 0.0242 END Z 0.000 0 19.906 0.494 0.0242 END Z 0.000 0 19.906 0.494 0.0242 END Z 0.000 0 19.906 0.494 0.0242 END Z 0.000 0 19.906 0.494 0.0242 END Z 0.000 0 19.906 0.494 0.0242 END Z 0.000 0 19.906 0.494 0.0242 END Z 0.000 0 19.906 0.494 0.0242 END Z 0.000 0 19.906 0.494 0.0242 END Z 0,000 0 19.906 0.494 0.0242 Totals: 0.828 202 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 2.42% Current: 0.828 Distance: 202 Voltage Drop: End of Line Voltage: 19.91 0.49 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 2.52% Current: 0.828 202 Distance: Voltage Drop: End of Line Voltage: 19.89 0.51 End of Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 5.03% Current: Distance: 0.828 202 Voltage Drop: End of Line Voltage: 19.37 1.03 Prosect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP2 Battery Calculations Standy Circuit / Device Current Alarm Current Qty Total Standy Current Total Alarm Current Power Supply 70 70 1 70 70 NAC Power NAC1 0 820 1 0 820 NAC2 0 0 0 0 0 NAC3 0 1555 1 0 1555 NAC4 54 828 1 54 0 200 mA Aux Power Aux 0 0 0 0 0 Aux 0 0 0 0 0 Aux 0 0 0 0 0 TOTALS: 124 2445 Total Standy Current (Amps): 0.124 X 24 Hours: 2.976 Amphours in Standy Total Alarm Current (Amps): 2.445 X 15 Mins: 0.61 Amphours in Alarm 3.59 Required Amphours Required Amphours: +20% Safety 3.59 4.30 Total Margin Am hours P (2) 12V 8Ah Batteries Required. "Magnetic Door Holders are not included in the battery calculations. Power to these devices will be automatically disconnected upon loss of A/C power to reduce battery size. V DEVICE LEGEND Devices Current (Milliamps) Designator Part Number Description LightOuput 0 15cd 30cd 75cd 95cd 110cd 177cd A B C D E F G H 1 J K L M N 0 P Q R S T U V W X Y SB4U SB4U-LF GSA-SBT SIGA-AB4G-LF INT-7ATW INT-8ATW EG1 F -HD EG1F-VM EG1F-HDVM EGCF-VM EGCF-VMH EGCF-HDVM EGCF-HDVMH G4LFWF-H G4LFWF-HVM G4HFWF-S7VMC GCHFWF-S7VMC INT-4ASW XXXX DHF -24120C C01224T XXXX XXXX XXXX XXXX Sounder Base for V Series Detectors 520Hz Sounder Base for V Series Detectors Sounder Base for PCOS Detectors 520Hz Sounder Base for PCOS Detectors WP Wall Mount Horn/Strobe WP Wall Mount Horn/Strobe Wall Mount Horn Wall Mount Strobe Wall Mount Horn/Strobe Ceiling Mount Strobe Ceiling Mount High Candela Strobe Ceiling Mount Horn/Strobe Ceiling Mount High Candela Horn/Strobe Wall Mount 520Hz Horn Wall Mount 520Hz Horn/Strobe Wall Mount Speaker/Strobe Ceiling Mount Speaker/Strobe Weatherproof Speaker/Strobe XXXX Magnetic Door Hold -Open Carbon Monoxide Detector XXXX XXXX XXXX XXXX 28 92 52 92 180 90 22 85 127 245 285 102 135 160 246 309 94 140 273 325 333 551 111 152 281 333 324 554 166 219 266 381 437 78 101 188 245 94 140 273 325 551 159 15 75 Z N/A END OF CIRCUIT V Prosect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP3 Circuit: NAC1 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.065 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 33 14 3.07 69 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 3.1.1 P 110 0.245 33 20.184 0.216 0.0106 3.1.2 P 110 0.245 23 20.068 0.332 0.0163 3.1.3 P 110 0.245 9 20.037 0.363 0.0178 3.1.4 H 15 0.085 8 20.020 0.380 0.0186 3.1.5 P 110 0.245 29 19.977 0.423 0.0207 END Z 0.000 0 19.977 0.423 0.0207 END Z 0.000 0 19.977 0.423 0.0207 END Z 0.000 0 19.977 0.423 0.0207 END Z 0.000 0 19.977 0.423 0.0207 END Z 0.000 0 19.977 0.423 0.0207 END Z 0.000 0 19.977 0.423 0.0207 END Z 0.000 0 19.977 0.423 0.0207 END Z 0.000 0 19.977 0.423 0.0207 END Z 0.000 0 19.977 0.423 0.0207 END Z 0.000 0 19.977 0.423 0.0207 END Z 0.000 0 19.977 0.423 0.0207 END Z 0.000 0 19.977 0.423 0.0207 END Z 0.000 0 19.977 0.423 0.0207 END Z 0.000 0 19.977 0.423 0.0207 END Z 0.000 0 19.977 0.423 0.0207 END Z 0.000 0 19.977 0.423 0.0207 Totals: 1.065 102 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 2.07% Current: I 1.065 Distance: 102 End Line Voltage: 19.98 Voltage Drop: 0.42 of CIRCUIT IS WITHIN LIMITS Load Centering Method Current:' 1.065 Percent Drop: 1.63% Distance: 102 End of Line Voltage: 20.07 Voltage Drop: 0.33 End Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 3.27% Current: 1.065 of Distance: 102 End Line Voltage: 19.73 Volta 9 a Dro 0.67 p:, of Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP3 Circuit: NAC2 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.47 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 80 14 3.07 103 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 3.2.1 P 110 0.245 80 19.678 0.722 0.0354 3.2.2 P 110 0.245 21 19.520 0.880 0.0431 3.2.3 P 110 0.245 22 19.388 1.012 0.0496 3.2.4 P 110 0.245 20 19.297 1.103 0.0541 3.2.5 P 110 0.245 19 19.240 1.160 0.0569 3.2.6 P 110 0.245 21 19.209 1.191 0.0584 END Z 0.000 0 19.209 1.191 0.0584 END Z 0.000 0 19.209 1.191 0.0584 END Z 0.000 0 19.209 1.191 0.0584 END Z 0.000 0 19.209 1.191 0.0584 END Z 0.000 0 19.209 1.191 0.0584 END Z 0.000 0 19.209 1.191 0.0584 END Z 0.000 0 19.209 1.191 0.0584 END Z 0.000 0 19.209 1.191 0.0584 END Z 0.000 0 19.209 1.191 0.0584 END Z 0.000 0 19.209 1.191 0.0584 END Z 0.000 0 19.209 1.191 0.0584 END Z 0.000 0 19.209 1.191 0.0584 END Z 0.000 0 19.209 1.191 0.0584 END Z 0.000 0 19.209 1.191 0.0584 END Z 0.000 0 19.209 1.191 0.0584 T +I40:Q42otals: 1.47 183 CIRCUIT IS WITHIN LIMITS Percent Drop: 5.84% Point to Point Method Current: 1.47 Distance: 183 Voltage Drop: End of Line Voltage: 19.21 1.19 CIRCUIT IS WITHIN LIMITS Load Centering Method Current: 1.47 Percent Drop: 4.05% 183 19.57 Distance: Voltage Drop: End of Line Voltage: 0.83 CIRCUIT IS WITHIN LIMITS Percent Drop: 8.10% End of Line Method Current: 1.47 183 18.75 Distance: Voltage Drop: End of Line Voltage: 1.65 Proiect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP3 Circuit: NAC3 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0.413 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guaae Ohms / 1000' 9 I 14 3.07 138 3.3.1 3.3.2 3.3.3 3.3.4 3.3.5 END END END END END END END END END END END END END END END END 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 3.3.1 3.3.2 3.3.3 3.3.4 3.3.5 END END END END END END END END END END END END END END END END P 30 P 15 P 15 P 15 P 15 Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Totals: 0.101 9 0.078 3 0.078 52 0.078 52 0.078 31 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.413 147 20.377 0.023 20.371 0.029 20.297 0.103 20.247 0.153 20.232 0.168 20.232 0.168 20.232 0.168 20.232 0.168 20.232 0.168 20.232 0.168 20.232 0.168 20.232 0.168 20.232 0.168 20.232 0.168 20.232 0.168 20.232 0.168 20.232 0.168 20.232 0.168 20.232 0.168 20.232 0.168 20.232 0.168 0.0011 0.0014 0.0051 0.0075 0.0082 0.0082 0.0082 0.0082 0.0082 0.0082 0.0082 0.0082 0.0082 0.0082 0.0082 0.0082 0.0082 0.0082 0.0082 0.0082 0.0082 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: End of Line Voltage: 0.82% Current: Distance: Voltage Drop: 0.413 147 20.23 0.17 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: End of Line Voltage: 0.91% Current: Distance: Voltage Drop: 0.413 147 20.21 0.19 End of Line Method CIRCUIT IS WITHIN LIMITSI Percent Drop: End of Line Voltage: j 1.83% Current: Distance: Voltage Drop: 0.413 147 20.03 0.37 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP3 Circuit: NAC4 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0.92 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guaae Ohms/ 1000' 37 14 3.07 186 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 3.4.1 D 0.092 37 20.191 0.209 0.0102 3.4.2 D 0.092 22 20.079 0.321 0.0157 3.4.3 D 0.092 21 19.984 0.416 0.0204 3.4.4 D 0.092 18 19.913 0.487 0.0239 3.4.5 D 0.092 20 19.845 0.555 0.0272 3.4.6 D 0.092 25 19.775 0.625 0.0307 3.4.7 D 0.092 21 19.727 0.673 0.0330 3.4.8 D 0.092 19 19.695 0.705 0.0346 3.4.9 D 0.092 19 19.674 0.726 0.0356 3.4.10 D 0.092 21 19.662 0.738 0.0362 END Z 0.000 0 19.662 0.738 0.0362 END Z 0.000 0 19.662 0.738 0.0362 END Z 0.000 0 19.662 0.738 0.0362 END Z 0.000 0 19.662 0.738 0.0362 END Z 0.000 0 19.662 0.738 0.0362 END Z 0.000 0 19.662 0.738 0.0362 END Z 0.000 0 19.662 0.738 0.0362 END Z 0.000 0 19.662 0.738 0.0362 END Z 0.000 0 19.662 0.738 0.0362 END Z 0.000 0 19.662 0.738 0.0362 END Z 0.000 0 19.662 0.738 0.0362 Totals: 0.92 223 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 3.62% Current: 0.92 Distance: 223 Voltage Drop: End of Line Voltage: 19.66 0.74 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 3.09% Current: 0.92 Distance: 223 Voltage Drop: End of Line Voltage: 19.77 0.63 End of Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 6.17% Current: Distance: 0.92 223 Voltage Drop: End of Line Voltage: 19.14 1.26 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP3 Battery Calculations Standy Alarm Circuit / Device Current Current Qty Total Standy Current Total Alarm Current Power Supply 70 70 1 70 70 NAC Power NAC1 0 1065 1 0 1065 NAC2 0 1470 1 0 1470 NAC3 0 413 1 0 413 NAC4 60 920 1 60 0 200 mA Aux Power Aux 0 0 0 0 0 Aux 0 0 0 0 0 Aux 0 0 0 0 0 TOTALS: 130 3018 Total Standy Current (Amps): 0.13 X 24 Hours: 3.12 Amphours in Standy Total Alarm Current (Amps): 3.018 X 15 Mins: 0.75 Amphours in Alarm 3.87 Required Amphours +20% Safety Tota! Required Amphours: 3.87 4.65 Margin Am hours p (2) 12V 8Ah Batteries Required. *Magnetic Door Holders are not included in the battery calculations. Power to these devices will be automatically disconnected upon Toss of A/C power to reduce battery size. DEVICE LEGEND Devices Current (Milliamps) Designator Part Number Description Light Ouput 0 15cd 30cd 75cd 95cd 110cd 177cd -<X*<C—ICn7JO'oOzKr c--IG)mmOC)oo> SB4U SB4U-LF GSA-SBT SIGA-AB4G-LF INT-7ATW INT-8ATW EG1F-HD EG1F-VM EG1F-HDVM EGCF-VM EGCF-VMH EGCF-HDVM EGCF-HDVMH G4LFWF-H G4LFWF-HVM G4HFWF-S7VMC GCHFWF-S7VMC INT-4ASW XXXX DHF-24120C C01224T XXXX XXXX XXXX XXXX Sounder Base for V Series Detectors 520Hz Sounder Base for V Series Detectors Sounder Base for PCOS Detectors 520Hz Sounder Base for PCOS Detectors WP Wall Mount Horn/Strobe WP Wall Mount Horn/Strobe Wall Mount Horn Wall Mount Strobe Wall Mount Horn/Strobe Ceiling Mount Strobe Ceiling Mount High Candela Strobe Ceiling Mount Horn/Strobe Ceiling Mount High Candela Horn/Strobe Wall Mount 520Hz Horn Wall Mount 520Hz Horn/Strobe Wall Mount Speaker/Strobe Ceiling Mount Speaker/Strobe Weatherproof Speaker/Strobe XXXX Magnetic Door Hold-Open Carbon Monoxide Detector XXXX XXXX XXXX XXXX 28 92 52 92 180 90 22 85 102 127 135 245 285 309 160 246 94 140 273 325 333 551 111 152 281 333 324 554 166 219 266 381 437 78 101 188 245 94 140 273 325 551 159 15 75 Z N/A END OF CIRCUIT Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP4 Circuit: NAC1 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.225 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 152 14 3.07 78 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 4.1.1 P 110 0.245 152 19.257 1.143 0.0560 4.1.2 P 110 0.245 20 19.136 1.264 0.0619 4.1.3 P 110 0.245 10 19.091 1.309 0.0642 4.1.4 P 110 0.245 42 18.965 1.435 0.0703 4.1.5 P 110 0.245 6 18.956 1.444 0.0708 END Z 0.000 0 18.956 1.444 0.0708 END Z 0.000 0 18.956 1.444 0.0708 END Z 0.000 0 18.956 1.444 0.0708 END Z 0.000 0 18.956 1.444 0.0708 END Z 0.000 0 18.956 1.444 0.0708 END Z 0.000 0 18.956 1.444 0.0708 END Z 0.000 0 18.956 1.444 0.0708 END Z 0.000 0 18.956 1.444 0.0708 END Z 0.000 0 18.956 1.444 0.0708 END Z 0.000 0 18.956 1.444 0.0708 END Z 0.000 0 18.956 1.444 0.0708 END Z 0.000 0 18.956 1.444 0.0708 END Z 0.000 0 18.956 1.444 0.0708 END Z 0.000 0 18.956 1.444 0.0708 END Z 0.000 0 18.956 1.444 0.0708 END Z 0.000 0 18.956 1.444 0.0708 Totals: 1.225 230 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 7.08% Current: !, 1.225 Distance: 230 End of Line Voltage: 18.96 Voltage Drop: 1.44 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 4.24% Current: 1.225 Distance: 230 End of Line Voltage: 19.54 Voltage Drop: 0.86 End of Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 8.48% Current: 1.225 Distance: 230 18.67 End of Line Voltage: Voltage Drop: 1.73 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP4 Circuit: NAC2 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.555 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms / 1000' 103 14 3.07 128 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 4.2.1 P 110 0.245 103 19.417 0.983 0.0482 4.2.2 P 110 0.245 26 19.207 1.193 0.0585 4.2.3 P 110 0.245 17 19.096 1.304 0.0639 4.2.4 P 110 0.245 37 18.910 1.490 0.0730 4.2.5 P 110 0.245 17 18.850 1.550 0.0760 4.2.6 H 15 0.085 8 18.834 1.566 0.0768 4.2.7 P 110 0.245 23 18.799 1.601 0.0785 END Z 0.000 0 18.799 1.601 0.0785 END Z 0.000 0 18.799 1.601 0.0785 END Z 0.000 0 18.799 1.601 0.0785 END Z 0.000 0 18.799 1.601 0.0785 END Z 0.000 0 18.799 1.601 0.0785 END Z 0.000 0 18.799 1.601 0.0785 END Z 0.000 0 18.799 1.601 0.0785 END Z 0.000 0 18.799 1.601 0.0785 END Z 0.000 0 18.799 1.601 0.0785 END Z 0.000 0 18.799 1.601 0.0785 END Z 0.000 0 18.799 1.601 0.0785 END Z 0.000 0 18.799 1.601 0.0785 END Z 0.000 0 18.799 1.601 0.0785 END Z 0.000 0 18.799 1.601 0.0785 T+I40:Q42otals: 1.555 231 CIRCUIT IS WITHIN LIMITS Percent Drop: 7.85% Current: 1.555 Point to Point Method 231 18.80 Distance: Voltage Drop: End of Line Voltage: 1.60 CIRCUIT IS WITHIN LIMITS Percent Drop: 5.41% Load Centering Method Current: 1.555 231 19.30 Distance: Voltage Drop: End of Line Voltage: 1.10 CIRCUIT IS WITHIN LIMITS Percent Drop: 10.81% Current: 1.555 End of Line Method 231 18.19 Distance: Voltage Drop: End of Line Voltage: 2.21 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP4 Circuit: NAC3 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.225 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guaae Ohms/ 1000' 15 14 3.07 94 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Percent Device Source Drop 4.3.1 P 110 0.245 15 20.287 0.113 0.0055 4.3.2 P 110 0.245 23 20.149 0.251 0.0123 4.3.3 P 110 0.245 33 20.000 0.400 0.0196 4.3.4 P 110 0.245 9 19.973 0.427 0.0209 4.3.5 P 110 0.245 29 19.929 0.471 0.0231 END Z 0.000 0 19.929 0.471 0.0231 END Z 0.000 0 19.929 0.471 0.0231 END Z 0.000 0 19.929 0.471 0.0231 END Z 0.000 0 19.929 0.471 0.0231 END Z 0.000 0 19.929 0.471 0.0231 END Z 0.000 0 19.929 0.471 0.0231 END Z 0.000 0 19.929 0.471 0.0231 END Z 0.000 0 19.929 0.471 0.0231 END Z 0.000 0 19.929 0.471 0.0231 END Z 0.000 0 19.929 0.471 0.0231 END Z 0.000 0 19.929 0.471 0.0231 END Z 0.000 0 19.929 0.471 0.0231 END Z 0.000 0 19.929 0.471 0.0231 END Z 0.000 0 19.929 0.471 0.0231 END Z 0.000 0 19.929 0.471 0.0231 END Z 0.000 0 19.929 0.471 0.0231 Totals: 1.225 109 CIRCUIT IS WITHIN LIMITS I Percent Drop:2.31% Current: 1.225 Point to Point Method Distance: End 109 Voltage Drop: 0.47 of Line Voltage: 19.93 CIRCUIT IS WITHIN LIMITS Percent Drop: 2.01% Load Centering Method Current: 1.225 I Distance: Voltage Drop: 109 End of Line Voltage: 19.99 0.41 CIRCUIT IS WITHIN LIMITS 1.225 Percent Drop:4.02% Current: End of Line Method Distance: End Line Voltage: 109 Voltage Drop: 0.82 of 19.58 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP4 Circuit: NAC4 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.012 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guaae Ohms/ 1000' 17 14 3.07 239 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 4.4.1 D 0.092 17 20.294 0.106 0.0052 4.4.2 D 0.092 25 20.153 0.247 0.0121 4.4.3 D 0.092 23 20.036 0.364 0.0178 4.4.4 D 0.092 22 19.937 0.463 0.0227 4.4.5 D 0.092 22 19.850 0.550 0.0270 4.4.6 D 0.092 26 19.762 0.638 0.0313 4.4.7 D 0.092 17 19.714 0.686 0.0336 4.4.8 D 0.092 24 19.659 0.741 0.0363 4.4.9 D 0.092 27 19.614 0.786 0.0385 4.4.10 D 0.092 28 19.582 0.818 0.0401 4.4.11 D 0.092 25 19.568 0.832 0.0408 END Z 0.000 0 19.568 0.832 0.0408 END Z 0.000 0 19.568 0.832 0.0408 END Z 0.000 0 19.568 0.832 0.0408 END Z 0.000 0 19.568 0.832 0.0408 END Z 0.000 0 19.568 0.832 0.0408 END Z 0.000 0 19.568 0.832 0.0408 END Z 0.000 0 19.568 0.832 0.0408 END Z 0.000 0 19.568 0.832 0.0408 END Z 0.000 0 19.568 0.832 0.0408 END Z 0.000 0 19.568 0.832 0.0408 Totals: 1.012 256 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 4.08% Current: 1.012 Distance: 256 Voltage Drop: End of Line Voltage: 19.57 0.83 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 3.90% Current: 1.012 Distance: 256 Voltage Drop: End of Line Voltage: 19.60 0.80 CIRCUIT IS WITHIN LIMITS Percent Drop: 7.80% Current: 1.012 End of Line Method 256 18.81 Distance: Voltage Drop: End of Line Voltage: 1.59 Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP4 Battery Calculations Standy Circuit / Device Current Alarm Current Qty Total Standy Current Total Alarm Current Power Supply 70 70 1 70 70 NAC Power NAC1 0 1225 1 0 1225 NAC2 0 1555 1 0 1555 NAC3 0 1225 1 0 1225 NAC4 66 1012 1 66 0 200 mA Aux Power Aux 0 0 0 0 0 Aux 0 0 0 0 0 Aux 0 0 0 0 0 TOTALS: 136 4075 Total Standy Current (Amps): 0.136 X 24 Hours: 3.264 Amphours in Standy Total Alarm Current (Amps): 4.075 X 15 Mins: 1.02 Amphours in Alarm 4.28 Required Amphours Required Amphours: +20% Safety 4.28 5.14 Total Margin Am hours p (2) 12V 8Ah Batteries Required. *Magnetic Door Holders are not included in the battery calculations. Power to these devices will be automatically disconnected upon loss of NC power to reduce battery size. DEVICE LEGEND Devices Current (Milliamps) Designator Part Number Description Light Ouput 0 15cd 30cd 75cd 95cd 110cd 177cd A B C D E F G H I J K L M N 0 P Q R S T U V W X Y SB4U SB4U-LF GSA-SBT SIGA-AB4G-LF INT-7ATW INT-8ATW EG1F-HD EG1F-VM EG1F-HDVM EGCF-VM EGCF-VMH EGCF-HDVM EGCF-HDVMH G4LFWF-H G4LFWF-HVM G4HFWF-S7VMC GCHFWF-S7VMC INT-4ASW XXXX DHF -24120C C01224T XXXX XXXX XXXX XXXX Sounder Base for V Series Detectors 520Hz Sounder Base for V Series Detectors Sounder Base for PCOS Detectors 520Hz Sounder Base for PCOS Detectors WP Wall Mount Horn/Strobe WP Wall Mount Horn/Strobe Wall Mount Horn Wall Mount Strobe Wall Mount Horn/Strobe Ceiling Mount Strobe Ceiling Mount High Candela Strobe Ceiling Mount Horn/Strobe Ceiling Mount High Candela Horn/Strobe Wall Mount 520Hz Horn Wall Mount 520Hz Horn/Strobe Wall Mount Speaker/Strobe Ceiling Mount Speaker/Strobe Weatherproof Speaker/Strobe )(XXX Magnetic Door Hold -Open Carbon Monoxide Detector )(XXX XXXX XXXX XXXX 28 92 52 92 180 90 22 85 127 245 285 102 135 160 246 309 94 140 273 325 333 551 111 152 281 333 324 554 166 219 266 381 437 78 101 188 245 94 140 273 325 551 159 15 75 Z N/A END OF CIRCUIT Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP5 Circuit: NAC1 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.47 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 38 14 3.07 98 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 5.1.1 P 110 0.245 38 20.057 0.343 0.0168 5.1.2 P 110 0.245 17 19.929 0.471 0.0231 5.1.3 P 110 0.245 24 19.785 0.615 0.0302 5.1.4 P 110 0.245 16 19.713 0.687 0.0337 5.1.5 P 110 0.245 24 19.640 0.760 0.0372 5.1.6 P 110 0.245 17 19.615 0.785 0.0385 END Z 0.000 0 19.615 0.785 0.0385 END Z 0.000 0 19.615 0.785 0.0385 END Z 0.000 0 19.615 0.785 0.0385 END Z 0.000 0 19.615 0.785 0.0385 END Z 0.000 0 19.615 0.785 0.0385 END Z 0.000 0 19.615 0.785 0.0385 END Z 0.000 0 19.615 0.785 0.0385 END Z 0.000 0 19.615 0.785 0.0385 END Z 0.000 0 19.615 0.785 0.0385 END Z 0.000 0 19.615 0.785 0.0385 END Z 0.000 0 19.615 0.785 0.0385 END Z 0.000 0 19.615 0.785 0.0385 END Z 0.000 0 19.615 0.785 0.0385 END Z 0.000 0 19.615 0.785 0.0385 END Z 0.000 0 19.615 0.785 0.0385 Totals: 1.47 136 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop 3.85% Current:: 1.47 Distance: 136 End of Line Voltage: 19.61 Voltage Drop: 0.79 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop 3.01% Current:; 1.47 Distance: 136 End Line Voltage: Voltage Drop: 0.61 of 19.79 End of Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 6.02% Current:, 1.47 Distance: i 136 19.17 End of Line Voltage: Voltage Drop: 1.23 Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP5 Circuit: NAC2 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.47 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 185 14 3.07 76 14 3.07 Low Frequency Device Device Distance Device from Voltage Drop Address Type / Current Previous Voltage at Drop From Percent Candela (Amps) Device Device Source Drop 5.2.1 P 110 0.245 185 18.730 1.670 0.0819 5.2.2 P 110 0.245 22 18.565 1.835 0.0900 5.2.3 P 110 0.245 9 18.511 1.889 0.0926 5.2.4 P 110 0.245 29 18.380 2.020 0.0990 5.2.5 P 110 0.245 7 18.359 2.041 0.1001 5.2.6 P 110 0.245 9 18.345 2.055 0.1007 END Z 0.000 0 18.345 2.055 0.1007 END Z 0.000 0 18.345 2.055 0.1007 END Z 0.000 0 18.345 2.055 0.1007 END Z 0.000 0 18.345 2.055 0.1007 END Z 0.000 0 18.345 2.055 0.1007 END Z 0.000 0 18.345 2.055 0.1007 END Z 0.000 0 18.345 2.055 0.1007 END Z 0.000 0 18.345 2.055 0.1007 END Z 0.000 0 18.345 2.055 0.1007 END Z 0.000 0 18.345 2.055 0.1007 END Z 0.000 0 18.345 2.055 0.1007 END Z 0.000 0 18.345 2.055 0.1007 END Z 0.000 0 18.345 2.055 0.1007 END Z 0.000 0 18.345 2.055 0.1007 END Z 0.000 0 18.345 2.055 0.1007 T+I40:Q42otals: 1.47 261 CIRCUIT IS WITHIN LIMITS Percent Drop: 10.07% Current: 1.47 Point to Point Method 261 18.35 Distance: Voltage Drop: End of Line Voltage: 2.05 CIRCUIT IS WITHIN LIMITS Load Centering Method Current: 1.47 Percent Drop: 5.77% 261 19.22 Distance: Voltage Drop: End of Line Voltage: 1.18 CIRCUIT IS WITHIN LIMITS Percent Drop: 11.55% End of Line Method Current: 1.47 261 18.04 Distance: Voltage Drop: End of Line Voltage: 2.36 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP5 Circuit: NAC3 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.555 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guaae Ohms/ 1000' 64 14 3.07 158 14 3.07 Low Frequency Device Device Address Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 5.3.1 P 110 0.245 64 19.789 0.611 0.0300 5.3.2 P 110 0.245 9 19.717 0.683 0.0335 5.3.3 H 15 0.085 7 19.671 0.729 0.0357 5.3.4 P 110 0.245 20 19.550 0.850 0.0416 5.3.5 P 110 0.245 19 19.465 0.935 0.0458 5.3.6 P 110 0.245 23 19.395 1.005 0.0492 5.3.7 P 110 0.245 80 19.275 1.125 0.0551 END Z 0.000 0 19.275 1.125 0.0551 END Z 0.000 0 19.275 1.125 0.0551 END Z 0.000 0 19.275 1.125 0.0551 END Z 0.000 0 19.275 1.125 0.0551 END Z 0.000 0 19.275 1.125 0.0551 END Z 0.000 0 19.275 1.125 0.0551 END Z 0.000 0 19.275 1.125 0.0551 END Z 0.000 0 19.275 1.125 0.0551 END Z 0.000 0 19.275 1.125 0.0551 END Z 0.000 0 19.275 1.125 0.0551 END Z 0.000 0 19.275 1.125 0.0551 END Z 0.000 019.275 1.125 0.0551 END Z 0.000 0 19.275 1.125 0.0551 END Z 0.000 C 19.275 1.125 0.0551 Totals: 1.555 222 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 5.51% Current: 1.555 Distance: Voltage Drop: 222 1 End of Line Voltage: 19.28 1.12 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 5.20% Current: 1.555 Distance: 222 Voltage Drop: End of Line Voltage: 19.34 1.06 End Line Method CIRCUIT 1S WITHIN LIMITS Percent Drop: 10.39% Current: 1.555 of Distance: 222 End Line Voltage: Voltage Drop: 2.12 of 18.28 Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP5 Circuit: NAC4 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.012 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Ouaae Ohms/ 1000' 37 14 3.07 212 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 5.4.1 D 0.092 37 20.170 0.230 0.0113 5.4.2 D 0.092 17 20.074 0.326 0.0160 5.4.3 D 0.092 24 19.952 0.448 0.0220 5.4.4 D 0.092 16 19.880 0.520 0.0255 5.4.5 D 0.092 24 19.785 0.615 0.0302 5.4.6 D 0.092 17 19.727 0.673 0.0330 5.4.7 D 0.092 19 19.674 0.726 0.0356 5.4.8 D 0.092 24 19.619 0.781 0.0383 5.4.9 D 0.092 22 19.582 0.818 0.0401 5.4.10 D 0.092 29 19.549 0.851 0.0417 5.4.11 D 0.092 20 19.538 0.862 0.0423 END Z 0.000 0 19.538 0.862 0.0423 END Z 0.000 0 19.538 0.862 0.0423 END Z 0.000 0 19.538 0.862 0.0423 END Z 0.000 0 19.538 0.862 0.0423 END Z 0.000 0 19.538 0.862 0.0423 END Z 0.000 0 19.538 0.862 0.0423 END Z 0.000 0 19.538 0.862 0.0423 END Z 0.000 0 19.538 0.862 0.0423 END Z 0.000 0 19.538 0.862 0.0423 END Z 0.000 0 19.538 0.862 0.0423 Totals: 1.012 249 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 4.23% Current: 1.012 Distance: 249 Voltage Drop: End of Line Voltage: 19.54 0.86 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 3.79% Current: 1.012 Distance: 249 Voltage Drop: End of Line Voltage: 19.63 0,77 End Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 7.58% Current: 1.012 of Distance: 249 Voltage Drop: End of Line Voltage: 18.85 1.55 Proiect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP5 Battery Calculations Standy Circuit / Device Current Alarm Current Qty Total Standy Current Total Alarm Current Power Supply 70 70 1 70 70 NAC Power NAC1 0 1470 1 0 1470 NAC2 0 1470 1 0 1470 NAC3 0 1555 1 0 1555 NAC4 66 1012 1 66 0 200 mA Aux Power Aux 0 0 0 0 0 Aux 0 0 0 0 0 Aux 0 0 0 0 0 TOTALS: 136 4565 Total Standy Current (Amps): 0.136 X 24 Hours: 3.264 Amphours in Standy Total Alarm Current (Amps): 4.565 X 15 Mins: 1.14 Amphours in Alarm 4.41 Required Amphours +20% Safety Total Required Amphours: 4.41 Margin 5'29 Amphours (2) 12V 8Ah Batteries Required. *Magnetic Door Holders are not included in the battery calculations. Power to these devices will be automatically disconnected upon Toss of A/C power to reduce battery size. DEVICE LEGEND Devices Current (Milliamps) Designator Part Number Description LightOuput 0 15cd 30cd 75cd 95cd 110cd 177cd A B C D E F G H I J K L M N 0 P Q R S T U V W X Y SB4U SB4U-LF GSA-SBT SIGA-AB4G-LF INT-7ATW INT-8ATW EG1F-HD EG1F-VM EG1F-HDVM EGCF-VM EGCF-VMH EGCF-HDVM EGCF-HDVMH G4LFWF-H G4LFWF-HVM G4HFWF-S7VMC GCHFWF-S7VMC INT-4ASW XXXX DHF-24120C C01224T XXXX XXXX XXXX XXXX Sounder Base for V Series Detectors 520Hz Sounder Base for V Series Detectors Sounder Base for PCOS Detectors 520Hz Sounder Base for PCOS Detectors WP Wall Mount Horn/Strobe WP Wall Mount Horn/Strobe Wall Mount Horn Wall Mount Strobe Wall Mount Horn/Strobe Ceiling Mount Strobe Ceiling Mount High Candela Strobe Ceiling Mount Horn/Strobe Ceiling Mount High Candela Horn/Strobe Wall Mount 520Hz Horn Wall Mount 520Hz Horn/Strobe Wall Mount Speaker/Strobe Ceiling Mount Speaker/Strobe Weatherproof Speaker/Strobe XXXX Magnetic Door Hold-Open Carbon Monoxide Detector XXXX XXXX XXXX XXXX 28 92 52 92 180 90 22 85 127 245 285 102 135 160 246 309 94 140 273 325 333 551 111 152 281 333 324 554 166 219 266 381 437 78 101 188 245 94 140 273 325 551 159 15 75 Z N/A END OF CIRCUIT Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP6 Circuit: NAC1 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0.491 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms / 1000' 8 14 3.07 210 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 6.1.1 P 15 0.078 8 20.376 0.024 0.0012 6.1.2 P 30 0.101 28 20.305 0.095 0.0047 6.1.3 P 15 0.078 29 20.249 0.151 0.0074 6.1.4 P 15 0.078 52 20.175 0.225 0.0110 6.1.5 P 15 0.078 50 20.127 0.273 0.0134 6.1.6 P 15 0.078 51 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 Totals: 0.491 218 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 1.46% Current:' 0.491 Distance: 218 End Line Voltage: Voltage Dro 0.30 9 p:1 of 20.10 CIRCUIT IS WITHIN LIMITS Percent Drop: 1.61% Load Centering Method Current: ! 0.491 Distance: 218 20.07 End of Line Voltage: Voltage Drop: 0.33 End Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 3.22% Current:' 0.491 of Distance: 218 End of Line Voltage: 19.74 Volta 9 a Dro 0.66 p:; Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP6 Circuit: NAC2 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 2.13 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guage Ohms/ 1000' 31 14 3.07 123 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 6.2.1 P 110 0.245 31 19.995 0.405 0.0199 6.2.2 P 110 0.245 9 19.890 0.510 0.0250 6.2.3 H 15 0.085 19 19.699 0.701 0.0344 6.2.4 P 110 0.245 8 19.623 0.777 0.0381 6.2.5 P 110 0.245 7 19.566 0.834 0.0409 6.2.6 P 110 0.245 9 19.508 0.892 0.0437 6.2.7 H 15 0.085 12 19.447 0.953 0.0467 6.2.8 P 110 0.245 43 19.253 1.147 0.0562 6.2.9 P 110 0.245 9 19.226 1.174 0.0575 6.2.10 P 110 0.245 7 19.215 1.185 0.0581 END Z 0.000 0 19.215 1.185 0.0581 END Z 0.000 0 19.215 1.185 0.0581 END Z 0.000 0 19.215 1.185 0.0581 END Z 0.000 0 19.215 1.185 0.0581 END Z 0.000 0 19.215 1.185 0.0581 END Z 0.000 0 19.215 1.185 0.0581 END Z 0.000 0 19.215 1.185 0.0581 END Z 0.000 0 19.215 1.185 0.0581 END Z 0.000 0 19.215 1.185 0.0581 END Z 0.000 0 19.215 1.185 0.0581 END Z 0.000 0 19.215 1.185 0.0581 T+I40:Q42otals: 2.13 154 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 5.81% Current: 2.13 Distance: 154 Voltage Drop: End of Line Voltage: 19.22 1.18 CIRCUIT IS WITHIN LIMITS Percent Drop: 4.94% Load Centering Method Current: 2.13 154 19.39 Distance: Voltage Drop: End of Line Voltage: 1.01 CIRCUIT IS WITHIN LIMITS Percent Drop: 9.87% End Line Method Current: 2.13 of Distance: 154 Voltage Drop: End of Line Voltage: 18.39 2.01 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP6 Circuit: NAC3 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guaae Ohms / 1000' 0 14 3.07 0 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 Totals: 0 0 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 Point to Point Method Distance: End Line 0 Voltage Drop: 0.00 of Voltage: 20.40 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Load Centering Method Current: 0 0 20.40 Distance: Voltage Drop: End of Line Voltage: 0.00 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 End of Line Method Distance: End Line 0 Voltage Drop: 0.00 of Voltage: 20.40 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP6 Circuit: NAC4 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.288 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guage Ohms/ 1000' 28 14 3.07 326 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 6.4.1 D 0.092 28 20.179 0.221 0.0109 6.4.2 D 0.092 21 20.024 0.376 0.0184 6.4.3 D 0.092 16 19.916 0.484 0.0237 6.4.4 D 0.092 21 19.785 0.615 0.0301 6.4.5 D 0.092 24 19.650 0.750 0.0368 6.4.6 D 0.092 19 19.553 0.847 0.0415 6.4.7 D 0.092 23 19.449 0.951 0.0466 6.4.8 D 0.092 81 19.129 1.271 0.0623 6.4.9 D 0.092 20 19.061 1.339 0.0656 6.4.10 D 0.092 25 18.991 1.409 0.0691 6.4.11 D 0.092 21 18.943 1.457 0.0714 6.4.12 D 0.092 12 18.923 1.477 0.0724 6.4.13 D 0.092 21 18.899 1.501 0.0736 6.4.14 D 0.092 22 18.887 1.513 0.0742 END Z 0.000 0 18.887 1.513 0.0742 END Z 0.000 0 18.887 1.513 0.0742 END Z 0.000 0 18.887 1.513 0.0742 END Z 0.000 0 18.887 1.513 0.0742 END Z 0.000 0 18.887 1.513 0.0742 END Z 0.000 0 18.887 1.513 0.0742 END Z 0.000 0 18.887 1.513 0.0742 Totals: 1.288 354 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 7.42% Current: 1.288 Distance: 354 Voltage Drop: End of Line Voltage: 18.89 1.51 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 6.86% Current: 1.288 Distance: 354 End Line Voltage: 19.00 Voltage Drop: 1.40 of End Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 13.72% Current: 1.288 of Distance: 354 Voltage Drop: End of Line Voltage: 17.60 2.80 PrOiect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP6 Battery Calculations Standy Circuit / Device Current Alarm Current Qty Total Standy Current Total Alarm Current Power Supply 70 70 1 70 70' NAC Power NAC1 0 491 1 0 491 NAC2 0 2130 1 0 2130 NAC3 0 0 0 0 0 NAC4 84 1288 1 84 0 200 mA Aux Power Aux 0 0 0 0 0 Aux 0 0 0 0 0 Aux 0 0 0 0 0 TOTALS: 154 2691 Total Standy Current (Amps): 0.154 X 24 Hours: 3.696 Amphours in Standy Total Alarm Current (Amps): 2.691 X 15 Mins: 0.67 Amphours in Alarm 4.37 Required Amphours +20% Safety Total Required Amphours: 4.37 5'24 Margin Am hours p (2) 12V 8Ah Batteries Required. *Magnetic Door Holders are not included in the battery calculations. Power to these devices will be automatically disconnected upon loss of NC power to reduce battery size. DEVICE LEGEND Devices Current (Milliamps) Designator Part Number Description Light Ouput 0 15cd 30cd 75cd 95cd 110cd 177cd A B C D E F G H I J K L M N 0 P Q R S T U V W X Y SB4U SB4U-LF GSA-SBT SIGA-AB4G-LF INT-7ATW INT-8ATW EG1F-HD EG1F-VM EG1F-HDVM EGCF-VM EGCF-VMH EGCF-HDVM EGCF-HDVMH G4LFWF-H G4LFWF-HVM G4HFWF-S7VMC GCHFWF-S7VMC INT-4ASW XXXX DHF-24120C C01224T XXXX XXXX XXXX XXXX Sounder Base for V Series Detectors 520Hz Sounder Base for V Series Detectors Sounder Base for PCOS Detectors 520Hz Sounder Base for PCOS Detectors WP Wall Mount Horn/Strobe WP Wall Mount Horn/Strobe Wall Mount Horn Wall Mount Strobe Wall Mount Horn/Strobe Ceiling Mount Strobe Ceiling Mount High Candela Strobe Ceiling Mount Horn/Strobe Ceiling Mount High Candela Horn/Strobe Wall Mount 520Hz Horn Wall Mount 520Hz Horn/Strobe Wall Mount Speaker/Strobe Ceiling Mount Speaker/Strobe Weatherproof Speaker/Strobe XXXX Magnetic Door Hold-Open Carbon Monoxide Detector XXXX XXXX XXXX XXXX 28 92 I 52 92 180 90 22 85 127 245 246 285 102 135 160 309 94 140 273 325 333 551 111 152 281 333 324 554 166 219 266 381 437 78 101 188 245 94 140 273 325 551 159 15 75 Z N/A END OF CIRCUIT Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP7 Circuit: NAC1 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.225 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 136 14 3.07 81 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 7.1.1 P 110 0.245 136 19.377 1.023 0.0501 7.1.2 P 110 0.245 22 19.245 1.155 0.0566 7.1.3 P 110 0.245 19 19.159 1.241 0.0608 7.1.4 P 110 0.245 22 19.093 1.307 0.0641 7.1.5 P 110 0.245 18 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 Totals: 1.225 217 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 6.54% Current: 1 1.225 Distance: 217 Voltage Drop: End of Line Voltage: 19.07 1.33 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 4.00% Current: 1.225 Distance: 217 End Line Voltage: 19.58 Voltage Drop: 0.82 of End Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 8.00% Current: 1.225 of Distance: 217 Voltage Drop: End of Line Voltage: 18.77 1.63 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP7 Circuit: NAC2 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.225 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000` 56 14 3.07 101 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 7.2.1 P 110 0.245 56 19.979 0.421 0.0206 7.2.2 P 110 0.245 32 19.786 0.614 0.0301 7.2.3 P 110 0.245 9 19.746 0.654 0.0321 7.2.4 P 110 0.245 35 19.640 0.760 0.0372 7.2.5 P 110 0.245 25 19.603 0.797 0.0391 END Z 0.000 0 19.603 0.797 0.0391 END Z 0.000 0 19.603 0.797 0.0391 END Z 0.000 0 19.603 0.797 0.0391 END Z 0.000 0 19.603 0.797 0.0391 END Z 0.000 0 19.603 0.797 0.0391 END Z 0.000 0 19.603 0.797 0.0391 END Z 0.000 0 19.603 0.797 0.0391 END Z 0.000 0 19.603 0.797 0.0391 END Z 0.000 0 19.603 0.797 0.0391 END Z 0.000 0 19.603 0.797 0.0391 END Z 0.000 0 19.603 0.797 0.0391 END Z 0.000 0 19.603 0.797 0.0391 END Z 0.000 0 19.603 0.797 0.0391 END Z 0.000 0 19.603 0.797 0.0391 END Z 0.000 0 19.603 0.797 0.0391 END Z 0.000 0 19.603 0.797 0.0391 T+I40:Q42otals: 1.225 157 1 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 3.91% Current: 1.225 157 19.60 Distance: Voltage Drop: End of Line Voltage: 0.80 CIRCUIT IS WITHIN LIMITS Percent Drop: 2.89% Load Centering Method Current: 1.225 157 19.81 Distance: Voltage Drop: End of Line Voltage: 0.59 CIRCUIT IS WITHIN LIMITS Percent Drop: 5.79% Current: 1.225 End of Line Method 157 19.22 Distance: Voltage Drop: End of Line Voltage: 1.18 Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP7 Circuit: NAC3 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0.491 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guaae Ohms / 1000' 6 I 14 3.07 205 ; 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 7.3.1 P 30 0.101 6 20.382 0.018 0.0009 7.3.2 P 15 0.078 16 20.344 0.056 0.0028 7.3.3 P 15 0.078 52 20.244 0.156 0.0076 7.3.4 P 15 0.078 53 20.168 0.232 0.0114 7.3.5 P 15 0.078 54 20.116 0.284 0.0139 7.3.6 P 15 0.078 30 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 Totals: 0.491 211 CIRCUIT IS WITHIN LIMITS Percent Drop: 1.46% Point to Point Method Current: 0.491 211 20.10 Distance: Voltage Drop: End of Line Voltage: 0.30 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 1.56% Current: 0.491 211 Distance: End Line Voltage: Voltage Drop: 0.32 of 20.08 CIRCUIT IS WITHIN LIMITS Percent Drop: 3.12% End of Line Method Current: 0.491 211 19.76 Distance: Voltage Drop: End of Line Voltage: 0.64 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP7 Circuit: NAC4 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guaae Ohms/ 1000' 0 14 3.07 0 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 Totals: 0 0 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 Distance: 0 Voltage Drop: End of Line Voltage: 20.40 0.00 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 Distance: 0 Voltage Drop: End of Line Voltage: 20.40 0.00 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% End of Line Method Current: 0 0 20.40 Distance: Voltage Drop: End of Line Voltage: 0.00 Prosect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP7 Battery Calculations Circuit / Device Standy Current Alarm Current Qty Total Standy Current Total Alarm Current Power Supply 70 70 1 70 70 NAC Power NAC1 0 1225 1 0 1225 NAC2 0 1225 1 0 1225 NAC3 0 491 1 0 491 NAC4 0 0 0 0 0 200 mA Aux Power Aux 0 0 0 0 0 Aux 0 0 0 0 0 Aux 0 0 0 0 0 TOTALS: 70 3011 Total Standy Current (Amps): 0.07 X 24 Hours: 1.68 Amphours in Standy Total Alarm Current (Amps): 3.011 X 15 Mins: 0.75 Amphours in Alarm 2.43 Required Amphours Required Amphours: +20% Safety 2.43 2.92 Total Margin Am hours p (2) 12V 3Ah Batteries Required. "Magnetic Door Holders are not included in the battery calculations. Power to these devices will be automatically disconnected upon loss of NC power to reduce battery size. DEVICE LEGEND Devices Current (Milliamps) Designator Part Number Description Light Ouput 0 15cd 30cd 75cd 95cd 110cd 177cd A B C D E F G H J K L M N 0 P Q R S T U V W X Y SB4U SB4U-LF GSA-SBT SIGA-AB4G-LF INT-7ATW INT-8ATW EG1F-HD EG1F-VM EG1F-HDVM EGCF-VM EGCF-VMH EGCF-HDVM EGCF-HDVMH G4LFWF-H G4LFWF-HVM G4HFWF-S7VMC GCHFWF-S7VMC INT-4ASW XXXX DHF -24120C C01224T XXXX XXXX XXXX XXXX Sounder Base for V Series Detectors 520Hz Sounder Base for V Series Detectors Sounder Base for PCOS Detectors 520Hz Sounder Base for PCOS Detectors WP Wall Mount Horn/Strobe WP Wall Mount Horn/Strobe Wall Mount Horn Wall Mount Strobe Wall Mount Horn/Strobe Ceiling Mount Strobe Ceiling Mount High Candela Strobe Ceiling Mount Horn/Strobe Ceiling Mount High Candela Horn/Strobe Wall Mount 520Hz Horn Wall Mount 520Hz Horn/Strobe Wall Mount Speaker/Strobe Ceiling Mount Speaker/Strobe Weatherproof Speaker/Strobe )(XXX Magnetic Door Hold -Open Carbon Monoxide Detector XXXX XXXX XXXX XXXX 28 92 52 92 180 90 22 85 127 245 285 102 135 160 246 309 94 140 273 325 333 551 111 152 281 333 324 554 166 219 266 381 437 78 101 188 245 94 140 273 325 551 159 15 75 Z N/A END OF CIRCUIT Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP8 Circuit: NAC1 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.47 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 103 14 3.07 128 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 8.1.1 P 110 0.245 103 19.470 0.930 0.0456 8.1.2 P 110 0.245 26 19.275 1.125 0.0552 8.1.3 P 110 0.245 21 19.148 1.252 0.0614 8.1.4 P 110 0.245 37 18.981 1.419 0.0695 8.1.5 P 110 0.245 21 18.918 1.482 0.0726 8.1.6 P 110 0.245 23 18.884 1.516 0.0743 END Z 0.000 0 18.884 1.516 0.0743 END Z 0.000 0 18.884 1.516 0.0743 END Z 0.000 0 18.884 1.516 0.0743 END Z 0.000 0 18.884 1.516 0.0743 END Z 0.000 0 18.884 1.516 0.0743 END Z 0.000 0 18.884 1.516 0.0743 END Z 0.000 0 18.884 1.516 0.0743 END Z 0.000 0 18.884 1.516 0.0743 END Z 0.000 0 18.884 1.516 0.0743 END Z 0.000 0 18.884 1.516 0.0743 END Z 0.000 0 18.884 1.516 0.0743 END Z 0.000 0 18.884 1.516 0.0743 END Z 0.000 0 18.884 1.516 0.0743 END Z 0.000 0 18.884 1.516 0.0743 END Z 0.000 0 18.884 1.516 0.0743 Totals: 1.47 231 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: End Line Voltage: 7.43% Current: I 1.47 Distance: 231 18.88 Voltage Drop:, 1.52 of Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop.5.11% Current:'I 1.47 Distance: j 231 End Line Voltage: Voltage Drop: j 1.04 of 19.36 End Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 10.22% Current: 1.47 of Distance: 231 End of Line Voltage: 18.32 Voltage Drop: 2.08 Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP8 Circuit: NAC2 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.31 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Ohms / Guacie 1000' 12 14 3.07 106 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 8.2.1 P 110 0.245 12 20.303 0.097 0.0047 8.2.2 P 110 0.245 26 20.133 0.267 0.0131 8.2.3 P 110 0.245 22 20.023 0.377 0.0185 8.2.4 P 110 0.245 9 19.991 0.409 0.0201 8.2.5 P 110 0.245 41 19.908 0.492 0.0241 8.2.6 H 15 0.085 8 19.904 0.496 0.0243 END Z 0.000 0 19.904 0.496 0.0243 END Z 0.000 0 19.904 0.496 0.0243 END Z 0.000 0 19.904 0.496 0.0243 END Z 0.000 0 19.904 0.496 0.0243 END Z 0.000 0 19.904 0.496 0.0243 END Z 0.000 0 19.904 0.496 0.0243 END Z 0.000 0 19.904 0.496 0.0243 END Z 0.000 0 19.904 0.496 0.0243 END Z 0.000 0 19.904 0.496 0.0243 END Z 0.000 0 19.904 0.496 0.0243 END Z 0.000 0 19.904 0.496 0.0243 END Z 0.000 0 19.904 0.496 0.0243 END Z 0.000 0 19.904 0.496 0.0243 END Z 0.000 0 19.904 0.496 0.0243 END Z 0.000 0 19.904 0.496 0.0243 T+I40:Q42otals: 1.31 118 CIRCUIT IS WITHIN LIMITS Percent Drop: 2.43% Point to Point Method Current: 1.31 118 19.90 Distance: Voltage Drop: End of Line Voltage: 0.50 CIRCUIT IS WITHIN LIMITS Percent Drop: 2.33% Load Centering Method Current: 1.31 118 19.93 Distance: Voltage Drop: End of Line Voltage: 0.47 CIRCUIT IS WITHIN LIMITS Percent Drop: 4.65% End of Line Method Current: 1.31 118 19.45 Distance: Voltage Drop: End of Line Voltage: 0.95 Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP8 Circuit: NAC3 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.225 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guaae Ohms/ 1000' 152 14 3.07 76 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 8.3.1 P 110 0.245 152 19.257 1.143 0.0560 8.3.2 P 110 0.245 19 19.142 1.258 0.0616 8.3.3 P 110 0.245 9 19.102 1.298 0.0636 8.3.4 P 110 0.245 39 18.984 1.416 0.0694 8.3.5 P 110 0.245 9 18.971 1.429 0.0701 END Z 0.000 0 18.971 1.429 0.0701 END Z 0.000 0 18.971 1.429 0.0701 END Z 0.000 0 18.971 1.429 0.0701 END Z 0.000 0 18.971 1.429 0.0701 END Z 0.000 0 18.971 1.429 0.0701 END Z 0.000 0 18.971 1.429 0.0701 END Z 0.000 0 18.971 1.429 0.0701 END Z 0.000 0 18.971 1.429 0.0701 END Z 0.000 0 18.971 1.429 0.0701 END Z 0.000 0 18.971 1.429 0.0701 END Z 0.000 0 18.971 1.429 0.0701 END Z 0.000 0 18.971 1.429 0.0701 END Z 0.000 0 18.971 1.429 0.0701 END Z 0.000 0 18.971 1.429 0.0701 END Z 0.000 0 18.971 1.429 0.0701 END Z 0.000 0 18.971 1.429 0.0701 Totals: 1.225 228 CIRCUIT IS WITHIN LIMITS Percent Drop: 7.01% Current: 1.225 Point to Point Method Distance: 228 End Line Voltage: Voltage Drop: 18.97 of 1.43 CIRCUIT IS WITHIN LIMITS 4.20% Current: Percent Drop: 1.225 Load Centering Method Distance: 228 End Line Voltage: Voltage Drop: of 0.86 19.54 CIRCUIT IS WITHIN LIMITS Percent Drop: 8.41% Current: 1.225 End of Line Method Distance: 228 End Line Voltage: 18.69 Voltage Drop: of 1.71 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP8 Circuit: NAC4 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.012 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guage Ohms/ 1000' 16 14 3.07 241 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 8.4.1 D 0.092 16 20.301 0.099 0.0049 8.4.2 D 0.092 18 20.199 0.201 0.0099 8.4.3 D 0.092 31 20.041 0.359 0.0176 8.4.4 D 0.092 15 19.974 0.426 0.0209 8.4.5 D 0.092 23 19.883 0.517 0.0254 8.4.6 D 0.092 28 19.788 0.612 0.0300 8.4.7 D 0.092 18 19.737 0.663 0.0325 8.4.8 D 0.092 27 19.676 0.724 0.0355 8.4.9 D 0.092 28 19.628 0.772 0.0378 8.4.10 D 0.092 24 19.601 0.799 0.0392 8.4.11 D 0.092 29 19.585 0.815 0.0400 END Z 0.000 0 19.585 0.815 0.0400 END Z 0.000 0 19.585 0.815 0.0400 END Z 0.000 0 19.585 0.815 0.0400 END Z 0.000 0 19.585 0.815 0.0400 END Z 0.000 0 19.585 0.815 0.0400 END Z 0.000 0 19.585 0.815 0.0400 END Z 0.000 0 19.585 0.815 0.0400 END Z 0.000 0 19.585 0.815 0.0400 END Z 0.000 0 19.585 0.815 0.0400 END Z 0.000 0 19.585 0.815 0.0400 Totals: 1.012 257 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 4.00% Current: 1.012 Distance: 257 Voltage Drop: End of Line Voltage: 19.58 0.82 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 3.91% Current: 1.012 257 - 19.60 Distance: Voltage Drop: End of Line Voltage: 0.80 End Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 7.83% Current: 1.012 of Distance: 257 Voltage Drop: End of Line Voltage: 18.80 1.60 Prosect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP8 Battery Calculations Standy Circuit / Device Current Alarm Current Qty Total Standy Current Total Alarm Current Power Supply 70 70 1 70 70 NAC Power NAC1 0 1470 1 0 1470 NAC2 0 1310 1 0 1310 NAC3 0 1225 1 0 1225 NAC4 66 1012 1 66 0 200 mA Aux Power Aux 0 0 0 0 0 Aux 0 0 0 0 0 Aux 0 0 0 0 0 TOTALS: 136 4075 Total Standy Current (Amps): 0.136 X 24 Hours: 3.264 Amphours in Standy Total Alarm Current (Amps): 4.075 X 15 Mins: 1.02 Amphours in Alarm 4.28 Required Amphours Required Amphours: +20% Safety 4.28 5.14 Total Margin Am hours p (2) 12V 8Ah Batteries Required. *Magnetic Door Holders are not included in the battery calculations. Power to these devices will be automatically disconnected upon loss of NC power to reduce battery size. DEVICE LEGEND Devices Current (Milliamps) Designator Part Number Description LightOuput 0 15cd 30cd 75cd 95cd 110cd 177cd < m U o W U 2-- Y-1g z O a O CCW H.> x>- SB4U SB4U-LF GSA-SBT SIGA-AB4G-LF INT-7ATW INT-8ATW EG1F-HD EG1F-VM EG1F-HDVM EGCF-VM EGCF-VMH EGCF-HDVM EGCF-HDVMH G4LFWF-H G4LFWF-HVM G4HFWF-S7VMC GCHFWF-S7VMC INT-4ASW XXXX DHF-24120C CO1224T XXXX XXXX XXXX XXXX Sounder Base for V Series Detectors 520Hz Sounder Base for V Series Detectors Sounder Base for PCOS Detectors 520Hz Sounder Base for PCOS Detectors WP Wall Mount Horn/Strobe WP Wall Mount Horn/Strobe Wall Mount Horn Wall Mount Strobe Wall Mount Horn/Strobe Ceiling Mount Strobe Ceiling Mount High Candela Strobe Ceiling Mount Horn/Strobe Ceiling Mount High Candela Horn/Strobe Wall Mount 520Hz Horn Wall Mount 520Hz Horn/Strobe Wall Mount Speaker/Strobe Ceiling Mount Speaker/Strobe Weatherproof Speaker/Strobe XXXX Magnetic Door Hold-Open Carbon Monoxide Detector XXXX XXXX XXXX )(XXX 28 92 52 92 180 90 22 85 102 127 245 285 135 160 246 309 94 140 273 325 333 551 111 152 281 333 324 554 166 219 266 381 437 78 101 188 245 94 140 273 325 551 159 15 75 Z N/A END OF CIRCUIT Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP9 Circuit: NAC1 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.47 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guacie Ohms/ 1000' 36 14 3.07 104 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Percent Device Source Drop 9.1.1 P 110 0.245 36 20.075 0.325 0.0159 9.1.2 P 110 0.245 20 19.925 0.475 0.0233 9.1.3 P 110 0.245 22 19.792 0.608 0.0298 9.1.4 P 110 0.245 20 19.702 0.698 0.0342 9.1.5 P 110 0.245 23 19.633 0.767 0.0376 9.1.6 P 110 0.245 19 19.604 0.796 0.0390 END Z 0.000 0 19.604 0.796 0.0390 END Z 0.000 0 19.604 0.796 0.0390 END Z 0.000 0 19.604 0.796 0.0390 END Z 0.000 0 19.604 0.796 0.0390 END Z 0.000 0 19.604 0.796 0.0390 END Z 0.000 0 19.604 0.796 0.0390 END Z 0.000 0 19.604 0.796 0.0390 END Z 0.000 0 19.604 0.796 0.0390 END Z 0.000 0 19.604 0.796 0.0390 END Z 0.000 0 19.604 0.796 0.0390 END Z 0.000 0 19.604 0.796 0.0390 END Z 0.000 0 19.604 0.796 0.0390 END Z 0.000 0 19.604 0.796 0.0390 END Z 0.000 0 19.604 0.796 0.0390 END Z 0.000 0 19.604 0.796 0.0390 Totals: 1.47 140 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 3.90% Current: 1.47 Distance: 140 End Line Voltage: Voltage Drop:, 0.80 of 19.60 CIRCUIT IS WITHIN LIMITS Percent Drop:3.10% Load Centering Method Current: 1.47 Distance: 140 19.77 End of Line Voltage: Voltage Drop: 0.63 End of Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 6.19% Current: 1.47 Distance: 140 End Line Voltage: 19.14 Volta 9 e Dro 1.26 p: of Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP9 Circuit: NAC2 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.715 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 167 14 3.07 95 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 9.2.1 P 110 0.245 167 18.641 1.759 0.0862 9.2.2 P 110 0.245 19 18.470 1.930 0.0946 9.2.3 P 110 0.245 18 18.335 2.065 0.1012 9.2.4 P 110 0.245 9 18.280 2.120 0.1039 9.2.5 P 110 0.245 33 18.132 2.268 0.1112 9.2.6 P 110 0.245 9 18.104 2.296 0.1125 9.2.7 P 110 0.245 7 18.094 2.306 0.1130 END Z 0.000 0 18.094 2.306 0.1130 END Z 0.000 0 18.094 2.306 0.1130 END Z 0.000 0 18.094 2.306 0.1130 END Z 0.000 0 18.094 2.306 0.1130 END Z 0.000 0 18.094 2.306 0.1130 END Z 0.000 0 18.094 2.306 0.1130 END Z 0.000 0 18.094 2.306 0.1130 END Z 0.000 0 18.094 2.306 0.1130 END Z 0.000 0 18.094 2.306 0.1130 END Z 0.000 0 18.094 2.306 0.1130 END Z 0.000 0 18.094 2.306 0.1130 END Z 0.000 0 18.094 2.306 0.1130 END Z 0.000 0 18.094 2.306 0.1130 END Z 0.000 0 18.094 2.306 0.1130 T+140:Q42otais: 1.715 262 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 11.30% Current: 1.715 Distance: 262 Voltage Drop: End of Line Voltage: 18.09 2.31 CIRCUIT IS WITHIN LIMITS Percent Drop: 6.76% Load Centering Method Current: 1.715 262 19.02 Distance: Voltage Drop: End of Line Voltage: 1.38 CIRCUIT IS WITHIN LIMITS Percent Drop: 13.52% End of Line Method Current: 1.715 262 17.64 Distance: Voltage Drop: End of Line Voltage: 2.76 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP9 Circuit: NAC3 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.225 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guaae Ohms/ 1000' 135 14 3.07 84 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 9.3.1 P 110 0.245 135 19.385 1.015 0.0498 9.3.2 P 110 0.245 23 19.246 1.154 0.0566 9.3.3 P 110 0.245 20 19.156 1.244 0.0610 9.3.4 P 110 0.245 19 19.099 1.301 0.0638 9.3.5 P 110 0.245 22 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 Totals: 1.225 219 Point to Point Method CIRCUIT IS WITHIN LIMITS 1 Percent Drop: 6.54% Current: 1.225 Distance: 219 End Line Voltage: Voltage Drop: 1.33 of 19.07 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 4.04% Current: 1.225 219 19.58 Distance: Voltage Drop: 1 End of Line Voltage: 0.82 End Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 8.07% Current: 1.225 of Distance: 219 Voltage Drop: End of Line Voltage: 18.75 1.65 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP9 Circuit: NAC4 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.012 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guage Ohms/ 1000' 34 14 3.07 206 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 9.4.1 D 0.092 34 20.189 0.211 0.0104 9.4.2 D 0.092 20 20.076 0.324 0.0159 9.4.3 D 0.092 21 19.969 0.431 0.0211 9.4.4 D 0.092 20 19.879 0.521 0.0256 9.4.5 D 0.092 23 19.788 0.612 0.0300 9.4.6 D 0.092 19 19.723 0.677 0.0332 9.4.7 D 0.092 19 19.670 0.730 0.0358 9.4.8 D 0.092 22 19.620 0.780 0.0382 9.4.9 D 0.092 19 19.588 0.812 0.0398 9.4.10 D 0.092 25 19.559 0.841 0.0412 9.4.11 D 0.092 18 19.549 0.851 0.0417 END Z 0.000 0 19.549 0.851 0.0417 END Z 0.000 0 19.549 0.851 0.0417 END Z 0.000 0 19.549 0.851 0.0417 END Z 0.000 0 19.549 0.851 0.0417 END Z 0.000 0 19.549 0.851 0.0417 END Z 0.000 0 19.549 0.851 0.0417 END Z 0.000 0 19.549 0.851 0.0417 END Z 0.000 0 19.549 0.851 0.0417 END Z 0.000 0 19.549 0.851 0.0417 END Z 0.000 0 19.549 0.851 0.0417 Totals: 1.012 240 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 4.17% Current: 1.012 Distance: 240 Voltage Drop: End of Line Voltage: 19.55 0.85 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 3.66% Current: 1.012 240 19.65 Distance: Voltage Drop: End of Line Voltage: 0.75 CIRCUIT IS WITHIN LIMITS Percent Drop: 7.31% End of Line Method Current: 1.012 240 18.91 Distance: Voltage Drop: End of Line Voltage: 1.49 Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP9 Battery Calculations Standy Circuit / Device Current Alarm Current Qty Total Standy Current Total Alarm Current Power Supply 70 70 1 70 70 NAC Power NAC1 0 1470 1 0 1470 NAC2 0 1715 1 0 1715 NAC3 0 1225 1 0 1225 NAC4 66 1012 1 66 0 200 mA Aux Power Aux 0 0 0 0 0 Aux 0 0 0 0 0 Aux 0 0 0 0 0 TOTALS: 136 4480 Total Standy Current (Amps): 0.136 X 24 Hours: 3.264 Amphours in Standy Total Alarm Current (Amps): 4.48 X 15 Mins: 1.12 Amphours in Alarm 4.38 Required Amphours +20% Safety Total Required Amphours: 4.38 Margin 5.26 hours Amphours (2) 12V 8Ah Batteries Required. *Magnetic Door Holders are not included in the battery calculations. Power to these devices will be automatically disconnected upon loss of NC power to reduce battery size. DEVICE LEGEND Devices Current (Milliamps) Designator Part Number Description Light ouput 0 15cd 30cd 75cd 95cd 110cd 177cd A B C D E F G H I J K L M N 0 P Q R S T U V W X Y SB4U SB4U-LF GSA-SBT SIGA-AB4G-LF INT-7ATW INT-8ATW EG1F-HD EG1F-VM EG1F-HDVM EGCF-VM EGCF-VMH EGCF-HDVM EGCF-HDVMH G4LFWF-H G4LFWF-HVM G4HFWF-S7VMC GCHFWF-S7VMC INT-4ASW XXXX DHF-24120C CO1224T XXXX XXXX XXXX XXXX Sounder Base for V Series Detectors 520Hz Sounder Base for V Series Detectors Sounder Base for PCOS Detectors 520Hz Sounder Base for PCOS Detectors WP Wall Mount Horn/Strobe WP Wall Mount Horn/Strobe Wall Mount Horn Wall Mount Strobe_ Wall Mount Horn/Strobe Ceiling Mount Strobe Ceiling Mount High Candela Strobe Ceiling Mount Horn/Strobe Ceiling Mount High Candela Horn/Strobe Wall Mount 520Hz Horn Wall Mount 520Hz Horn/Strobe Wall Mount Speaker/Strobe Ceiling Mount Speaker/Strobe Weatherproof Speaker/Strobe XXXX Magnetic Door Hold-Open Carbon Monoxide Detector XXXX XXXX XXXX )(XXX 28 92 52 92 180 90 22 85 102 127 135 245 160 246 285 309 94 140 273 325 333 551 111 152 281 333 324 554 166 219 266 381 437 78 101 188 245 94 140 273 325 551 159 15 75 Z N/A END OF CIRCUIT Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP10 Circuit: NAC1 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0.491 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 36 14 3.07 207 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 10.1.1 P 15 0.078 36 20.291 0.109 0.0053 10.1.2 P 30 0.101 25 20.228 0.172 0.0084 10.1.3 P 15 0.078 30 20.171 0.229 0.0112 10.1.4 P 15 0.078 52 20.096 0.304 0.0149 10.1.5 P 15 0.078 50 20.048 0.352 0.0173 10.1.6 P 15 0.078 50 20.024 0.376 0.0184 END Z 0.000 0 20.024 0.376 0.0184 END Z 0.000 0 20.024 0.376 0.0184 END Z 0.000 0 20.024 0.376 0.0184 END Z 0.000 0 20.024 0.376 0.0184 END Z 0.000 0 20.024 0.376 0.0184 END Z 0.000 0 20.024 0.376 0.0184 END Z 0.000 0 20.024 0.376 0.0184 END Z 0.000 0 20.024 0.376 0.0184 END Z 0.000 0 20.024 0.376 0.0184 END Z 0.000 0 20.024 0.376 0.0184 END Z 0.000 0 20.024 0.376 0.0184 END Z 0.000 0 20.024 0.376 0.0184 END Z 0.000 0 20.024 0.376 0.0184 END Z 0.000 0 20.024 0.376 0.0184 END Z 0.000 0 20.024 0.376 0.0184 Totals: 0.491 243 CIRCUIT IS WITHIN LIMITS Percent Drop: 1.84% Current: 0.491 Point to Point Method End Line Voltage: Distance:! 243 Voltage Drop: 0.38 of 20.02 CIRCUIT IS WITHIN LIMITS Percent Drop: 1.80% Current: 0.491 Load Centering Method End Line Voltage: Distance: 243 20.03 Volta 9 e Dro 0.37 p:, of CIRCUIT IS WITHIN LIMITS Percent Drop: 3.59% Current:' 0.491 End of Line Method Distance: 243 End of Line Voltage: 19.67 Voltage Drop: 0.73 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP10 Circuit: NAC2 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.8 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Ouaae Ohms/ 1000' 37 14 3.07 124 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 10.2.1 P 110 0.245 37 19.991 0.409 0.0200 10.2.2 P 110 0.245 9 19.905 0.495 0.0243 10.2.3 P 110 0.245 23 19.720 0.680 0.0333 10.2.4 P 110 0.245 20 19.589 0.811 0.0397 10.2.5 P 110 0.245 22 19.479 0.921 0.0452 10.2.6 P 110 0.245 23 19.397 1.003 0.0491 10.2.7 H 15 0,085 7 19.383 1.017 0.0498 10.2.8 P 110 0.245 20 19.353 1.047 0.0513 END Z 0.000 0 19.353 1.047 0.0513 END Z 0.000 0 19.353 1.047 0.0513 END Z 0.000 0 19.353 1.047 0.0513 END Z 0.000 0 19.353 1.047 0.0513 END Z 0.000 0 19.353 1.047 0.0513 END Z 0.000 0 19.353 1.047 0.0513 END Z 0.000 0 19.353 1.047 0.0513 END Z 0.000 0 19.353 1.047 0.0513 END Z 0.000 0 19.353 1.047 0.0513 END Z 0.000 0 19.353 1.047 0.0513 END Z 0.000 0 19.353 1.047 0.0513 END Z 0.000 0 19.353 1.047 0.0513 END Z 0.000 0 19.353 1.047 0.0513 T+I40: Q42otals: 1.8 161 CIRCUIT IS WITHIN LIMITS Point to Point Method Percent Drop: 5.13% Current: 1.8 161 19.35 Distance: End of Line Voltage: 1.05 Voltage Drop: CIRCUIT IS WITHIN LIMITS Percent Drop: 4.36% Load Centering Method Current: 1.8 161 19.51 Distance: End of Line Voltage: 0.89 Voltage Drop: CIRCUIT IS WITHIN LIMITS Percent Drop: 8.72% Current: 1.8 End of Line Method 161 18.62 Distance: End of Line Voltage: 1.78 Voltage Drop: Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP10 Circuit: NAC3 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.96 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guaae Ohms/ 1000' 32 14 3.07 106 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 10.3.1 P 110 0.245 32 20.015 0.385 0.0189 10.3.2 P 110 0.245 9 19.920 0.480 0.0235 10.3.3 P 110 0.245 20 19.740 0.660 0.0324 10.3.4 P 110 0.245 7 19.687 0.713 0.0350 10.3.5 P 110 0.245 9 19.633 0.767 0.0376 10.3.6 P 110 0.245 45 19.430 0.970 0.0476 10.3.7 P 110 0.245 9 19.403 0.997 0.0489 10.3.8 P 110 0.245 7 19.392 1.008 0.0494 END Z 0.000 0 19.392 1.008 0.0494 END Z 0.000 0 19.392 1.008 0.0494 END Z 0.000 0 19.392 1.008 0.0494 END Z 0.000 0 19.392 1.008 0.0494 END Z 0.000 0 19.392 1.008 0.0494 END Z 0.000 0 19.392 1.008 0.0494 END Z 0.000 0 19.392 1.008 0.0494 END Z 0.000 0 19.392 1.008 0.0494 END Z 0.000 0 19.392 1.008 0.0494 END Z 0.000 0 19.392 1.008 0.0494 END Z 0.000 0 19.392 1.008 0.0494 END Z 0.000 0 19.392 1.008 0.0494 END Z 0.000 0 19.392 1.008 0.0494 Totals: 1.96 138 CIRCUIT IS WITHIN LIMITS Percent Drop: 4.94% Current: 1.96 Point to Point Method Distance: End Line Voltage: 138 Voltage Drop: 1.01 of 19.39 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 4.07% Current: 1.96 138 19.57 Distance: Voltage Drop: End of Line Voltage: 0.83 CIRCUIT IS WITHIN LIMITS Percent Drop: 8.14% Current: 1.96 End of Line Method Distance: End Line Voltage: 138 18.74 Voltage Drop: 1.66 of Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP10 Circuit: NAC4 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.472 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guaae Ohms/ 1000' 28 14 3.07 296 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 10.4.1 D 0.092 28 20.147 0.253 0.0124 10.4.2 D 0.092 19 19.986 0.414 0.0203 10.4.3 D 0.092 15 19.867 0.533 0.0261 10.4.4 D 0.092 20 19.720 0.680 0.0333 10.4.5 D 0.092 26 19.544 0.856 0.0420 10.4.6 D 0.092 20 19.420 0.980 0.0480 10.4.7 D 0.092 21 19.301 1.099 0.0539 10.4.8 D 0.092 22 19.189 1.211 0.0593 10.4.9 D 0.092 19 19.104 1.296 0.0635 10.4.10 D 0.092 20 19.025 1.375 0.0674 10.4.11 D 0.092 19 18.960 1.440 0.0706 10.4.12 D 0.092 22 18.898 1.502 0.0736 10.4.13 D 0.092 21 18.851 1.549 0.0760 10.4.14 D 0.092 11 18.832 1.568 0.0769 10.4.15 D 0.092 22 18.807 1.593 0.0781 10.4.16 D 0.092 19 18.796 1.604 0.0786 END Z 0.000 0 18.796 1.604 0.0786 END Z 0.000 0 18.796 1.604 0.0786 END Z 0.000 0 18.796 1.604 0.0786 END Z 0.000 0 18.796 1.604 0.0786 END Z 0.000 0 18.796 1.604 0.0786 Totals: 1.472 324 CIRCUIT IS WITHIN LIMITS Point to Point Method Percent Drop: 7.86% Current: 1.472 Distance: 324 Voltage Drop: End of Line Voltage: 18.80 1.60 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 7.18% Current: 1.472 324 18.94 Distance: Voltage Drop: End of Line Voltage: 1.46 End Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 14.35% Current: 1.472 of Distance: 324 Voltage Drop: End of Line Voltage: 17.47 2.93 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP1O Battery Calculations Standy Circuit / Device Current Alarm Current Qty Total Standy Current Total Alarm Current Power Supply 70 70 1 70 70 NAC Power NAC1 0 491 1 0 491 NAC2 0 1800 1 0 1800 NAC3 0 1960 1 0 1960 NAC4 96 1472 1 96 0 200 mA Aux Power Aux 0 0 0 0 0 Aux 0 0 0 0 0 Aux 0 0 0 0 0 TOTALS: 166 4321 Total Standy Current (Amps): 0.166 X 24 Hours: 3.984 Amphours in Standy Total Alarm Current (Amps): 4.321 X 15 Mins: 1.08 Amphours in Alarm 5.06 Required Amphours +20% Safety Total Required Amphours: 5.06 Margin 6.08 hours Amphours (2) 12V 8Ah Batteries Required. *Magnetic Door Holders are not included in the battery calculations. Power to these devices will be automatically disconnected upon loss of NC power to reduce battery size. DEVICE LEGEND Devices Current (Milliamps) Designator Part Number Description Light Ouput 0 15cd 30cd 75cd 95cd 110cd 177cd A B C D E F G H I J K L M N 0 P Q R S T U V W X Y SB4U SB4U-LF GSA-SBT SIGA-AB4G-LF INT-7ATW INT-8ATW EG1F-HD EG1F-VM EG1F-HDVM EGCF-VM EGCF-VMH EGCF-HDVM EGCF-HDVMH G4LFWF-H G4LFWF-HVM G4HFWF-S7VMC GCHFWF-S7VMC INT-4ASW XXXX DHF -24120C C01224T XXXX XXXX XXXX XXXX Sounder Base for V Series Detectors 520Hz Sounder Base for V Series Detectors Sounder Base for PCOS Detectors 520Hz Sounder Base for PCOS Detectors WP Wall Mount Horn/Strobe WP Wall Mount Horn/Strobe Wall Mount Horn Wall Mount Strobe Wall Mount Horn/Strobe Ceiling Mount Strobe Ceiling Mount High Candela Strobe Ceiling Mount Horn/Strobe Ceiling Mount High Candela Horn/Strobe Wall Mount 520Hz Horn Wall Mount 520Hz Horn/Strobe Wall Mount Speaker/Strobe Ceiling Mount Speaker/Strobe Weatherproof Speaker/Strobe XXXX Magnetic Door Hold -Open Carbon Monoxide Detector XXXX XXXX XXXX XXXX 28 92 52 92 180 90 22 85 127 245 285 102 135 160 246 309 94 140 273 325 333 551 111 152 281 333 324 554 166 219 266 381 437 78 101 188 245 94 140 273 325 551 159 15 75 Z N/A END OF CIRCUIT Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP11 Circuit: NAC1 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.31 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 56 14 3.07 101 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 11.1.1 P 110 0.245 56 19.950 0.450 0.0221 11.1.2 H 15 0.085 8 19.897 0.503 0.0246 11.1.3 P 110 0.245 29 19.723 0.677 0.0332 11.1.4 P 110 0.245 9 19.682 0.718 0.0352 11.1.5 P 110 0.245 29 19.595 0.805 0.0395 11.1.6 P 110 0.245 26 19.556 0.844 0.0414 END Z 0.000 0 19.556 0.844 0.0414 END Z 0.000 0 19.556 0.844 0.0414 END Z 0.000 0 19.556 0.844 0.0414 END Z 0.000 0 19.556 0.844 0.0414 END Z 0.000 0 19.556 0.844 0.0414 END Z 0.000 0 19.556 0.844 0.0414 END Z 0.000 0 19.556 0.844 0.0414 END Z 0.000 0 19.556 0.844 0.0414 END Z 0.000 0 19.556 0.844 0.0414 END Z 0.000 0 19.556 0.844 0.0414 END Z 0.000 0 19.556 0.844 0.0414 END Z 0.000 0 19.556 0.844 0.0414 END Z 0.000 0 19.556 0.844 0.0414 END Z 0.000 0 19.556 0.844 0.0414 END Z 0.000 0 19.556 0.844 0.0414 Totals: 1.31 157 CIRCUIT IS WITHIN LIMITS Percent Drop: 4.14% Current: 1.31 Point to Point Method Distance: End Line Voltage: 157 19.56 Voltage Drop: 0.84 of Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 3.10% Current: 1.31 157 19.77 Distance:! End Line Voltage: Voltage Drop:, 0.63 of End of Line Method _CIRCUIT IS WITHIN LIMITS Percent Drop: 6.19% Current: 1 1.31 157 19.14 Distance:: End Line Voltage: Voltage Drop:; 1.26 of Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP11 Circuit: NAC2 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0.491 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guage Ohms/ 1000' 26 14 3.07 229 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 11.2.1 P 30 0.101 26 20.322 0.078 0.0038 11.2.2 P 15 0.078 15 20.286 0.114 0.0056 11.2.3 P 15 0.078 52 20.186 0.214 0.0105 11.2.4 P 15 0.078 55 20.107 0.293 0.0144 11.2.5 P 15 0.078 52 20.057 0.343 0.0168 11.2.6 P 15 0.078 55 20.031 0.369 0.0181 END Z 0.000 0 20.031 0.369 0.0181 END Z 0.000 0 20.031 0.369 0.0181 END Z 0.000 0 20.031 0.369 0.0181 END Z 0.000 0 20.031 0.369 0.0181 END Z 0.000 0 20.031 0.369 0.0181 END Z 0.000 0 20.031 0.369 0.0181 END Z 0.000 0 20.031 0.369 0.0181 END Z 0.000 0 20.031 0.369 0.0181 END Z 0.000 0 20.031 0.369 0.0181 END Z 0.000 0 20.031 0.369 0.0181 END Z 0.000 0 20.031 0.369 0.0181 END Z 0.000 0 20.031 0.369 0.0181 END Z 0.000 0 20.031 0.369 0.0181 END Z 0.000 0 20.031 0.369 0.0181 END Z 0.000 0 20.031 0.369 0.0181 T+I40:Q42otals: 0.491 255 CIRCUIT IS WITHIN LIMITS Percent Drop: 1.81% Point to Point Method Current: 0.491 Distance: 255 Voltage Drop: End of Line Voltage: 20.03 0.37 CIRCUIT IS WITHIN LIMITS Load Centering Method Current: 0.491 Percent Drop: 1.88% Distance: 255 Voltage Drop: End of Line Voltage: 20.02 0.38 CIRCUIT IS WITHIN LIMITS Percent Drop: End Line Method Current: 0.491 3.77% of Distance: 255 Voltage Drop: End of Line Voltage: 19.63 0.77 PrOiect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP11 Circuit: NAC3 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guaae Ohms/ 1000' 0 14 3.07 0 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 Totals: 0 0 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 Point to Point Method Distance: End Line Voltage: 0 Voltage Drop: 0.00 of 20.40 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 0 20.40 Distance: Voltage Drop: End of Line Voltage: 0.00 End of Line Method CIRCUIT IS WITHIN LIMITS I Percent Drop: 0.00% Current: 0 0 20.40 Distance: End Line Voltage: Voltage Drop: 0.00 of Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP11 Circuit: NAC4 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.472 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guaae Ohms/ 1000' 37 14 3.07 307 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 11.4.1 D 0.092 37 20.066 0.334 0.0164 11.4.2 D 0.092 23 19.871 0.529 0.0259 11.4.3 D 0.092 27 19.657 0.743 0.0364 11.4.4 D 0.092 13 19.562 0.838 0.0411 11.4.5 D 0.092 22 19.413 0.987 0.0484 11.4.6 D 0.092 20 19.288 1.112 0.0545 11.4.7 D 0.092 18 19.187 1.213 0.0595 11.4.8 D 0.092 22 19.075 1.325 0.0650 11.4.9 D 0.092 19 18.989 1.411 0.0692 11.4.10 D 0.092 22 18.902 1.498 0.0734 11.4.11 D 0.092 25 18.817 1.583 0.0776 11.4.12 D 0.092 22 18.755 1.645 0.0806 11.4.13 D 0.092 22 18.705 1.695 0.0831 11.4.14 D 0.092 19 18.673 1.727 0.0846 11.4.15 D 0.092 19 18.652 1.748 0.0857 11.4.16 D 0.092 14 18.644 1.756 0.0861 END Z 0.000 0 18.644 1.756 0.0861 END Z 0.000 0 18.644 1.756 0.0861 END Z 0.000 0 18.644 1.756 0.0861 END Z 0.000 0 18.644 1.756 0.0861 END Z 0.000 0 18.644 1.756 0.0861 Totals: 1.472 344 CIRCUIT IS WITHIN LIMITS Point to Point Method Current: 1.472 Percent Drop: 8.61% Distance: 344 Voltage Drop: End of Line Voltage:, 18.64 1.76 CIRCUIT IS WITHIN LIMITS Percent Drop: 7.62% Load Centering Method Current: 1.472 344 18.85 Distance: Voltage Drop: End of Line Voltage: 1.55 End Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 15.24% Current: 1.472 of Distance: 344 Voltage Drop: End of Line Voltage: 17.29 3.11 Prosect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP11 Battery Calculations Standy Circuit / Device Current Alarm Current Qty Total Standy Current Total Alarm Current Power Supply 70 70 1 70 70 NAC Power NAC1 0 1310 1 0 1310 NAC2 0 491 1 0 491 NAC3 0 0 0 0 0 NAC4 96 1472 1 96 0 200 mA Aux Power Aux 0 0 0 0 0 Aux 0 0 0 0 0 Aux 0 0 0 0 0 TOTALS: 166 1871 Total Standy Current (Amps): 0.166 X 24 Hours: 3.984 Amphours in Standy Total Alarm Current (Amps): 1.871 X 15 Mins: 0.47 Amphours in Alarm 4.45 Required Amphours Required Amphours: +20% Safety 4.45 6.34 Total Margin Am hours p (2) 12V 8Ah Batteries Required. "Magnetic Door Holders are not included in the battery calculations. Power to these devices will be automatically disconnected upon loss of NC power to reduce battery size. DEVICE LEGEND Devices Current (Milliamps) Designator Part Number Description Light Ouput 0 15cd 30cd 75cd 95cd 110cd 177cd A B C D E F G H I J K L M N 0 P Q R S T U V W X Y SB4U SB4U-LF GSA-SBT SIGA-AB4G-LF INT-7ATW INT-8ATW EG1F-HD EG1F-VM EG1F-HDVM EGCF-VM EGCF-VMH EGCF-HDVM EGCF-HDVMH G4LFWF-H G4LFWF-HVM G4HFWF-S7VMC GCHFWF-S7VMC INT-4ASW XXXX DHF-24120C C01224T XXXX XXXX XXXX XXXX Sounder Base for V Series Detectors 520Hz Sounder Base for V Series Detectors Sounder Base for PCOS Detectors 520Hz Sounder Base for PCOS Detectors WP Wall Mount Horn/Strobe WP Wall Mount Horn/Strobe Wall Mount Horn Wall Mount Strobe Wall Mount Horn/Strobe Ceiling Mount Strobe Ceiling Mount High Candela Strobe Ceiling Mount Horn/Strobe Ceiling Mount High Candela Horn/Strobe Wall Mount 520Hz Horn Wall Mount 520Hz Horn/Strobe Wall Mount Speaker/Strobe Ceiling Mount Speaker/Strobe Weatherproof Speaker/Strobe XXXX Magnetic Door Hold-Open Carbon Monoxide Detector XXXX XXXX XXXX XXXX 28 92 52 92 180 90 22 85 102 127 245 285 135 160 246 309 94 140 273 325 333 551 111 152 281 333 324 554 166 219 266 381 437 78 101 188 245 94 140 273 325 551 159 15 75 Z N/A END OF CIRCUIT Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP12 Circuit: NAC1 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.225 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms / 1000' 148 14 3.07 80 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 12.1.1 P 110 0.245 148 19.287 1.113 0.0546 12.1.2 P 110 0.245 22 19.154 1.246 0.0611 12.1.3 P 110 0.245 19 19.069 1.331 0.0653 12.1.4 P 110 0.245 19 19.012 1.388 0.0681 12.1.5 P 110 0.245 20 18.981 1.419 0.0695 END Z 0.000 0 18.981 1.419 0.0695 END Z 0.000 0 18.981 1.419 0.0695 END Z 0.000 0 18.981 1.419 0.0695 END Z 0.000 0 18.981 1.419 0.0695 END Z 0.000 0 18.981 1.419 0.0695 END Z 0.000 0 18.981 1.419 0.0695 END Z 0.000 0 18.981 1.419 0.0695 END Z 0.000 0 18.981 1.419 0.0695 END Z 0.000 0 18.981 1.419 0.0695 END Z 0.000 0 18.981 1.419 0.0695 END Z 0.000 0 18.981 1.419 0.0695 END Z 0.000 0 18.981 1.419 0.0695 END Z 0.000 0 18.981 1.419 0.0695 END Z 0.000 0 18.981 1.419 0.0695 END Z 0.000 0 18.981 1.419 0.0695 END Z 0.000 0 18.981 1.419 0.0695 Totals: 1.225 228 CIRCUIT IS WITHIN LIMITS Percent Drop: 6.95% Current: 1.225 Point to Point Method End Line Voltage: Distance: 228 Voltage Drop: 1.42 of 18.98 CIRCUIT IS WITHIN LIMITS Percent Drop: 4.20% Current: 1.225 Load Centering Method Distance: 228 End of Line Voltage: 19.54 Voltage Drop: 0.86 CIRCUIT IS WITHIN LIMITS Percent Drop: 8.41% Current: 1.225 End of Line Method End Line Voltage: Distance:' 228 18.69 Voltage Drop: r 1.71 of Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP12 Circuit: NAC2 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.225 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaoe Ohms/ 1000' 69 14 3.07 93 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 12.2.1 P 110 0.245 69 19.881 0.519 0.0254 12.2.2 P 110 0.245 23 19.743 0.657 0.0322 12.2.3 P 110 0.245 9 19.702 0.698 0.0342 12.2.4 P 110 0.245 38 19.588 0.812 0.0398 12.2.5 P 110 0.245 23 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 Totals: 1.225 162 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 4.15% Current: 1.225 Distance: 162 Voltage Drop: End of Line Voltage: 19.55 0.85 CIRCUIT IS WITHIN LIMITS Percent Drop: 2.99% Load Centering Method Current: 1.225 162 19.79 Distance: Voltage Drop: End of Line Voltage: 0.61 CIRCUIT IS WITHIN LIMITS Percent Drop: 5.97% End of Line Method Current: 1.225 162 19.18 Distance: Voltage Drop: End of Line Voltage: 1.22 Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP12 Circuit: NAC3 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 2.13 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guaae Ohms/ 1000' 44 14 3.07 138 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 12.3.1 P 110 0.245 44 19.825 0.575 0.0282 12.3.2 P 110 0.245 9 19.720 0.680 0.0333 12.3.3 P 110 0.245 19 19.529 0.871 0.0427 12.3.4 P 110 0.245 6 19.478 0.922 0.0452 12.3.5 P 110 0.245 9 19.414 0.986 0.0483 12.3.6 P 110 0.245 42 19.181 1.219 0.0598 12.3.7 P 110 0.245 11 19.136 1.264 0.0620 12.3.8 H 15 0.085 10 19.111 1.289 0.0632 12.3.9 P 110 0.245 25 19.060 1.340 0.0657 12.3.10 H 15 0.085 7 19.056 1.344 0.0659 END Z 0.000 0 19.056 1.344 0.0659 END Z 0.000 0 19.056 1.344 0.0659 END Z 0.000 0 19.056 1.344 0.0659 END Z 0.000 0 19.056 1.344 0.0659 END Z 0.000 0 19.056 1.344 0.0659 END Z 0.000 0 19.056 1.344 0.0659 END Z 0.000 0 19.056 1.344 0.0659 END Z 0.000 0 19.056 1.344 0.0659 END Z 0.000 0 19.056 1.344 0.0659 END Z 0.000 0 19.056 1.344 0.0659 END Z 0.000 0 19.056 1.344 0.0659 Totals: 2.13 182 CIRCUIT IS WITHIN LIMITS Percent Drop: 6.59% Current: 2.13 Point to Point Method Distance: End Line Voltage: 182 Voltage Drop: 1.34 of 19.06 CIRCUIT IS WITHIN LIMITS Percent Drop: 5.83% Load Centering Method Current: 2.13 182 19.21 Distance: Voltage Drop: End of Line Voltage: 1.19 CIRCUIT IS WITHIN LIMITS Percent Drop: 11.67% Current: 2.13 End of Line Method 182 18.02 Distance: Voltage Drop: End of Line Voltage: 2.38 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP12 Circuit: NAC4 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.472 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guage Ohms/ 1000` 39 14 3.07 295 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 12.4.1 D 0.092 39 20.048 0.352 0.0173 12.4.2 D 0.092 20 19.878 0.522 0.0256 12.4.3 D 0.092 16 19.752 0.648 0.0318 12.4.4 D 0.092 20 19.605 0.795 0.0390 12.4.5 D 0.092 25 19.435 0.965 0.0473 12.4.6 D 0.092 19 19.317 1.083 0.0531 12.4.7 D 0.092 22 19.193 1.207 0.0592 12.4.8 D 0.092 20 19.091 1.309 0.0642 12.4.9 D 0.092 22 18.992 1.408 0.0690 12.4.10 D 0.092 18 18.921 1.479 0.0725 12.4.11 D 0.092 21 18.849 1.551 0.0760 12.4.12 D 0.092 19 18.796 1.604 0.0786 12.4.13 D 0.092 21 18.748 1.652 0.0810 12.4.14 D 0.092 11 18.730 1.670 0.0819 12.4.15 D 0.092 22 18.705 1.695 0.0831 12.4.16 D 0.092 19 18.694 1.706 0.0836 END Z 0.000 0 18.694 1.706 0.0836 END Z 0.000 0 18.694 1.706 0.0836 END Z 0.000 0 18.694 1.706 0.0836 END Z 0.000 0 18.694 1.706 0.0836 END Z 0,000 0 18.694 1.706 0.0836 Totals: 1.472 334 CIRCUIT IS WITHIN LIMITS Point to Point Method Percent Drop: 8.36% Current: 1.472 Distance: 334 Voltage Drop: End of Line Voltage: 18.69 1.71 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 7.40% Current: 1.472 Distance: 334 Voltage Drop: End of Line Voltage: 18.89 1.51 End Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 14.80% Current: 1.472 of Distance: 334 Voltage Drop: End of Line Voltage: 17.38 3.02 Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP12 Battery Calculations Standy Circuit / Device Current Alarm Current Qty Total Standy Current Total Alarm Current Power Supply 70 70 1 70 70 NAC Power NAC1 0 1225 1 0 1225 NAC2 0 1225 1 0 1225 NAC3 0 2130 1 0 2130 NAC4 96 1472 1 96 0 200 mA Aux Power Aux 0 0 0 0 0 Aux 0 0 0 0 0 Aux 0 0 0 0 0 TOTALS: 166 4650 Total Standy Current (Amps): 0.166 X 24 Hours: 3.984 Amphours in Standy Total Alarm Current (Amps): 4.65 X 15 Mins: 1.16 Amphours in Alarm 5.15 Required Amphours +20% Safety Total Required Amphours: 5.15 Margin 6'18 hours Amphours (2) 12V 8Ah Batteries Required. *Magnetic Door Holders are not included in the battery calculations. Power to these devices will be automatically disconnected upon loss of NC power to reduce battery size. DEVICE LEGEND Devices Current (Milliamps) Designator Part Number Description Light Ouput 0 15cd 30cd 75cd 95cd 110cd 177cd A B C D E F G H I J K L M N 0 P Q R S T U V W X Y SB4U SB4U-LF GSA-SBT SIGA-AB4G-LF INT-7ATW INT-8ATW EG1 F-HD EG1F-VM EG1F-HDVM EGCF-VM EGCF-VMH EGCF-HDVM EGCF-HDVMH G4LFWF-H G4LFWF-HVM G4HFWF-S7VMC GCHFWF-S7VMC INT-4ASW XXXX DHF-24120C C01224T XXXX XXXX XXXX XXXX Sounder Base for V Series Detectors 520Hz Sounder Base for V Series Detectors Sounder Base for PCOS Detectors 520Hz Sounder Base for PCOS Detectors WP Wall Mount Horn/Strobe WP Wall Mount Horn/Strobe Wall Mount Horn Wall Mount Strobe Wall Mount Horn/Strobe Ceiling Mount Strobe Ceiling Mount High Candela Strobe Ceiling Mount Horn/Strobe Ceiling Mount High Candela Horn/Strobe Wall Mount 520Hz Horn Wall Mount 520Hz Horn/Strobe Wall Mount Speaker/Strobe Ceiling Mount Speaker/Strobe Weatherproof Speaker/Strobe XXXX Magnetic Door Hold-Open Carbon Monoxide Detector XXXX XXXX XXXX XXXX 28 92 52 92 180 90 22 85 127 245 246 285 309 102 135 160 94 140 273 325 333 551 111 152 281 333 324 554 166 219 266 381 437 78 101 188 245 94 140 273 325 551 159 15 75 Z N/A END OF CIRCUIT Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP13 Circuit: NAC1 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0.569 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 27 14 3.07 218 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 13.1.1 P 15 0.078 27 20.306 0.094 0.0046 13.1.2 P 15 0.078 7 20.285 0.115 0.0057 13.1.3 P 30 0.101 29 20.211 0.189 0.0093 13.1.4 P 15 0.078 30 20.154 0.246 0.0121 13.1.5 P 15 0.078 52 20.079 0.321 0.0157 13.1.6 P 15 0.078 50 20.031 0.369 0.0181 13.1.7 P 15 0.078 50 20.007 0.393 0.0193 END Z 0.000 0 20.007 0.393 0.0193 END Z 0.000 0 20.007 0.393 0.0193 END Z 0.000 0 20.007 0.393 0.0193 END Z 0.000 0 20.007 0.393 0.0193 END Z 0.000 0 20.007 0.393 0.0193 END Z 0.000 0 20.007 0.393 0.0193 END Z 0.000 0 20.007 0.393 0.0193 END Z 0.000 0 20.007 0.393 0.0193 END Z 0.000 0 20.007 0.393 0.0193 END Z 0.000 0 20.007 0.393 0.0193 END Z 0.000 0 20.007 0.393 0.0193 END Z 0.000 0 20.007 0.393 0.0193 END Z 0.000 0 20.007 0.393 0.0193 END Z 0.000 0 20.007 0.393 0.0193 Totals: 0.569 245 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 1.93% Current: 0.569 Distance: 245 20.01 End Line Voltage: Voltage Drop: 0.39 of CIRCUIT IS WITHIN LIMITS Percent Drop: 2.10% Current: 0.569 Load Centering Method Distance: 245 End of Line Voltage: 19.97 Volta 9 a Dro 0.43 p: CIRCUIT IS WITHIN LIMITS Percent Drop: 4.20% Current: T 0.569 End of Line Method Distance: 245 End of Line Voltage: 19.54 Voltage Drop: 0.86 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP13 Circuit: NAC2 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.715 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaoe Ohms/ 1000' 35 14 3.07 114 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 13.2.1 P 110 0.245 35 20.031 0.369 0.0181 13.2.2 P 110 0.245 9 19.950 0.450 0.0220 13.2.3 P 110 0.245 22 19.785 0.615 0.0302 13.2.4 P 110 0.245 19 19.670 0.730 0.0358 13.2.5 P 110 0.245 22 19.571 0.829 0.0406 13.2.6 P 110 0.245 20 19.511 0.889 0.0436 13.2.7 P 110 0.245 22 19.478 0.922 0.0452 END Z 0.000 0 19.478 0.922 0.0452 END Z 0.000 0 19.478 0.922 0.0452 END Z 0.000 0 19.478 0.922 0.0452 END Z 0.000 0 19.478 0.922 0.0452 END Z 0.000 0 19.478 0.922 0.0452 END Z 0.000 0 19.478 0.922 0.0452 END Z 0.000 0 19.478 0.922 0.0452 END Z 0.000 0 19.478 0.922 0.0452 END Z 0.000 0 19.478 0.922 0.0452 END Z 0.000 0 19.478 0.922 0.0452 END Z 0.000 0 19.478 0.922 0.0452 END Z 0.000 0 19.478 0.922 0.0452 END Z 0.000 0 19.478 0.922 0.0452 END Z 0.000 0 19.478 0.922 0.0452 Totals: 1.715 149 CIRCUIT IS WITHIN LIMITS Point to Point Method Current: 1.715 Percent Drop: 4.52% Distance: 149 End Line Voltage: 19.48 Voltage Drop: 0.92 of CIRCUIT IS WITHIN LIMITS Percent Drop: 3.85% Load Centering Method Current: 1.715 149 19.62 Distance: Voltage Drop: End of Line Voltage: 0.78 CIRCUIT IS WITHIN LIMITS Percent Drop: 7.69% End of Line Method Current: 1.715 149 18.83 Distance: Voltage Drop: End of Line Voltage: 1.57 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP13 Circuit: NAC3 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.8 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 152 14 3.07 104 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 13.3.1 P 110 0.245 152 18.720 1.680 0.0823 13.3.2 P 110 0.245 21 18.520 1.880 0.0922 13.3.3 P 110 0.245 16 18.391 2.009 0.0985 13.3.4 P 110 0.245 9 18.332 2.068 0.1014 13.3.5 H 15 0.085 7 18.297 2.103 0.1031 13.3.6 P 110 0.245 35 18.139 2.261 0.1108 13.3.7 P 110 0.245 9 18.112 2.288 0.1122 13.3.8 P 110 0.245 7 18.101 2.299 0.1127 END Z 0.000 0 18.101 2.299 0.1127 END Z 0.000 0 18.101 2.299 0.1127 END Z 0.000 0 18.101 2.299 0.1127 END Z 0.000 0 18.101 2.299 0.1127 END Z 0.000 0 18.101 2.299 0.1127 END Z 0.000 0 18.101 2.299 0.1127 END Z 0.000 0 18.101 2.299 0.1127 END Z 0.000 0 18.101 2.299 0.1127 END Z 0.000 0 18.101 2.299 0.1127 END Z 0.000 0 18.101 2.299 0.1127 END Z 0.000 0 18.101 2.299 0.1127 END Z 0.000 0 18.101 2.299 0.1127 END Z 0.000 0 18.101 2.299 0.1127 Totals: 1.8 256 CIRCUIT IS WITHIN LIMITS Percent Drop: 11.27% Current: 1.8 Point to Point Method Distance: 256 Voltage Drop: End of Line Voltage: 18.10 2.30 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 6.93% Current: 1.8 256 18.99 Distance: Voltage Drop: End of Line Voltage: 1.41 CIRCUIT IS WITHIN LIMITS Percent Drop: 13.87% Current: 1.8 End of Line Method Distance: 256 Voltage Drop: End of Line Voltage: 17.57 2.83 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP13 Circuit: NAC4 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.012 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 48 14 3.07 207 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 13.4.1 D 0.092 48 20.102 0.298 0.0146 13.4.2 D 0.092 19 19.994 0.406 0.0199 13.4.3 D 0.092 22 19.883 0.517 0.0254 13.4.4 D 0.092 19 19.797 0.603 0.0296 13.4.5 D 0.092 23 19.706 0.694 0.0340 13.4.6 0 0.092 19 19.641 0.759 0.0372 13.4.7 D 0.092 18 19.591 0.809 0.0397 13.4.8 D 0.092 22 19.541 0.859 0.0421 13.4.9 D 0.092 20 19.507 0.893 0.0438 13.4.10 D 0.092 26 19.478 0.922 0.0452 13.4.11 D 0.092 19 19.467 0.933 0.0457 END Z 0.000 0 19.467 0.933 0.0457 END Z 0.000 0 19.467 0.933 0.0457 END Z 0.000 0 19.467 0.933 0.0457 END Z 0.000 0 19.467 0.933 0.0457 END Z 0.000 0 19.467 0.933 0.0457 END Z 0.000 0 19.467 0.933 0.0457 END Z 0.000 0 19.467 0.933 0.0457 END Z 0.000 0 19.467 0.933 0.0457 END Z 0.000 0 19.467 0.933 0.0457 END Z 0.000 0 19.467 0.933 0.0457 Totals: 1.012 255 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 4.57% Current: 1.012 Distance: 255 Voltage Drop: End of Line Voltage: 19.47 0.93 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 3.88% Current: 1.012 Distance: 255 Voltage Drop: End of Line Voltage: 19.61 0.79 CIRCUIT IS WITHIN LIMITS Percent Drop: 7.77% End of Line Method Current: 1.012 255 18.82 Distance: Voltage Drop: End of Line Voltage: 1.58 Prosect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP13 Battery Calculations Circuit / Device Standy Current Alarm Current Qty Total Standy Current Total Alarm Current Power Supply 70 70 1 70 70 NAC Power NAC1 0 569 1 0 569 NAC2 0 1715 1 0 1715 NAC3 0 1800 1 0 1800 NAC4 66 1012 1 66 0 200 mA Aux Power Aux 0 0 0 0 0 Aux 0 0 0 0 0 Aux 0 0 0 0 0 TOTALS: 136 4154 Total Standy Current (Amps): 0.136 X 24 Hours: 3.264 Amphours in Standy Total Alarm Current (Amps): 4.154 X 15 Mins: 1.04 Amphours in Alarm 4.30 Required Amphours +20% Safety Total Required Amphours: 4.30 Margin 5.16 Amphours (2) 12V 8Ah Batteries Required. *Magnetic Door Holders are not included in the battery calculations. Power to these devices will be automatically disconnected upon loss of NC power to reduce battery size. DEVICE LEGEND Devices Current (Milliamps) Designator Part Number Description Light Ouput 0 15cd 30cd 75cd 95cd 110cd 177cd A 6 C D E F G H J K L M N 0 P Q R S T U V W X Y SB4U SB4U-LF GSA-SBT SIGA-AB4G-LF INT-7ATW INT-8ATW EG1F-HD EG1F-VM EG1F-HDVM EGCF-VM EGCF-VMH EGCF-HDVM EGCF-HDVMH G4LFWF-H G4LFWF-HVM G4HFWF-S7VMC GCHFWF-S7VMC INT-4ASW XXXX DHF -24120C C01224T XXXX XXXX XXXX XXXX Sounder Base for V Series Detectors 520Hz Sounder Base for V Series Detectors Sounder Base for PCOS Detectors 520Hz Sounder Base for PCOS Detectors WP Wall Mount Horn/Strobe WP Wall Mount Horn/Strobe Wall Mount Horn Wall Mount Strobe Wall Mount Horn/Strobe Ceiling Mount Strobe Ceiling Mount High Candela Strobe Ceiling Mount Horn/Strobe Ceiling Mount High Candela Horn/Strobe Wall Mount 520Hz Horn Wall Mount 520Hz Horn/Strobe Wall Mount Speaker/Strobe Ceiling Mount Speaker/Strobe Weatherproof Speaker/Strobe XXXX Magnetic Door Hold -Open Carbon Monoxide Detector XXXX XXXX XXXX XXXX 28 92 52 92 180 90 22 85 127 245 285 102 135 160 246 309 94 140 273 325 333 551 111 152 281 333 324 554 166 219 266 381 437 78 101 188 245 94 140 273 325 551 159 15 75 Z N/A END OF CIRCUIT Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP14 Circuit: NAC1 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.47 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guage Ohms/ 1000' 37 14 3.07 103 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 14.1.1 P 110 0.245 37 20.066 0.334 0.0164 14.1.2 P 110 0.245 19 19.923 0.477 0.0234 14.1.3 P 110 0.245 22 19.791 0.609 0.0299 14.1.4 P 110 0.245 19 19.705 0.695 0.0341 14.1.5 P 110 0.245 23 19.636 0.764 0.0375 14.1.6 P 110 0.245 20 19.606 0.794 0.0389 END Z 0.000 0 19.606 0.794 0.0389 END Z 0.000 0 19.606 0.794 0.0389 END Z 0.000 0 19.606 0.794 0.0389 END Z 0.000 0 19.606 0.794 0.0389 END Z 0.000 0 19.606 0.794 0.0389 END Z 0.000 0 19.606 0.794 0.0389 END Z 0.000 0 19.606 0.794 0.0389 END Z 0.000 0 19.606 0.794 0.0389 END Z 0.000 0 19.606 0.794 0.0389 END Z 0.000 0 19.606 0.794 0.0389 END Z 0.000 0 19.606 0.794 0.0389 END Z 0.000 0 19.606 0.794 0.0389 END Z 0.000 0 19.606 0.794 0.0389 END Z 0.000 0 19.606 0.794 0.0389 END Z 0.000 0 19.606 0.794 0.0389 Totals: 1.47 140 CIRCUIT IS WITHIN LIMITS Percent Drop: 3.89% Current:' 1.47 Point to Point Method Distance: 140 End of Line Voltage: 19.61 Voltage Drop: 0.79 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop:. 3.10% Current:' 1.47 Distance: 140 19.77 End of Line Voltage: Voltage Drop: 0.63 CIRCUIT IS WITHIN LIMITS Percent Drop: 6.19% Current:) 1.47 End of Line Method End Line Voltage: Distance: 140 19.14 Voltage Drop: j 1.26 of Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP14 Circuit: NAC2 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.225 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 152 14 3.07 76 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 14.2.1 P 110 0.245 152 19.257 1.143 0.0560 14.2.2 P 110 0.245 18 19.148 1.252 0.0614 14.2.3 P 110 0.245 9 19.108 1.292 0.0633 14.2.4 P 110 0.245 40 18.987 1.413 0.0692 14.2.5 P 110 0.245 9 18.974 1.426 0.0699 END Z 0.000 0 18.974 1.426 0.0699 END Z 0.000 0 18.974 1.426 0.0699 END Z 0.000 0 18.974 1.426 0.0699 END Z 0.000 0 18.974 1.426 0.0699 END Z 0.000 0 18.974 1.426 0.0699 END Z 0.000 0 18.974 1.426 0.0699 END Z 0.000 0 18.974 1.426 0.0699 END Z 0.000 0 18.974 1.426 0.0699 END Z 0.000 0 18.974 1.426 0.0699 END Z 0.000 0 18.974 1.426 0.0699 END Z 0.000 0 18.974 1.426 0.0699 END Z 0.000 0 18.974 1.426 0.0699 END Z 0.000 0 18.974 1.426 0.0699 END Z 0.000 0 18.974 1.426 0.0699 END Z 0.000 0 18.974 1.426 0.0699 END Z 0.000 0 18.974 1.426 0.0699 Totals: 1.225 228 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 6.99% Current: 1.225 Distance: 228 End Line Voltage: 18.97 Voltage Drop: 1.43 of CIRCUIT IS WITHIN LIMITS Percent Drop: 4.20% Load Centering Method Current: 1.225 228 19.54 Distance: Voltage Drop: End of Line Voltage: 0.86 CIRCUIT IS WITHIN LIMITS Percent End Line Method Current: 1.225 Drop: 8.41% of Distance: 228 Voltage Drop: End of Line Voltage: 18.69 1.71 Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP14 Circuit: NAC3 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.47 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaoe Ohms/ 1000' 101 14 3.07 119 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 14.3.1 P 110 0.245 101 19.488 0.912 0.0447 14.3.2 P 110 0.245 29 19.270 1.130 0.0554 14.3.3 P 110 0.245 17 19.168 1.232 0.0604 14.3.4 P 110 0.245 34 19.015 1.385 0.0679 14.3.5 P 110 0.245 16 18.966 1.434 0.0703 14.3.6 P 110 0.245 23 18.932 1.468 0.0720 END Z 0.000 0 18.932 1.468 0.0720 END Z 0.000 0 18.932 1.468 0.0720 END Z 0.000 0 18.932 1.468 0.0720 END Z 0.000 0 18.932 1.468 0.0720 END Z 0.000 0 18.932 1.468 0.0720 END Z 0.000 0 18.932 1.468 0.0720 END Z 0.000 0 18.932 1.468 0.0720 END Z 0.000 0 18.932 1.468 0.0720 END Z 0.000 0 18.932 1.468 0.0720 END Z 0.000 0 18.932 1.468 0.0720 END Z 0.000 0 18.932 1.468 0.0720 END Z 0.000 0 18.932 1.468 0.0720 END Z 0.000 0 18.932 1.468 0.0720 END Z 0.000 0 18.932 1.468 0.0720 END Z 0.000 0 18.932 1.468 0.0720 Totals: 1.47 220 CIRCUIT IS WITHIN LIMITS Percent Drop: 7.20% Current: 1.47 Point to Point Method Distance: End Line 220 Voltage Drop: 1.47 of Voltage: 18.93 CIRCUIT IS WITHIN LIMITS Percent Drop: 4.87% Load Centering Method Current: 1.47 Distance: Voltage Drop: 220 End of Line Voltage: 19.41 0.99 CIRCUIT IS WITHIN LIMITS Percent Drop: 9.73% Current: 1.47 End of Line Method Distance: End Line Voltage: 220 Voltage Drop: 1.99 of 18.41 Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP14 Circuit: NAC4 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.472 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 49 14 3.07 303 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 14.4.1 D 0.092 49 19.957 0.443 0.0217 14.4.2 D 0.092 19 19.796 0.604 0.0296 14.4.3 D 0.092 25 19.598 0.802 0.0393 14.4.4 D 0.092 14 19.496 0.904 0.0443 14.4.5 D 0.092 18 19.374 1.026 0.0503 14.4.6 D 0.092 16 19.274 1.126 0.0552 14.4.7 D 0.092 19 19.167 1.233 0.0604 14.4.8 D 0.092 28 19.025 1.375 0.0674 14.4.9 D 0.092 17 18.948 1.452 0.0712 14.4.10 D 0.092 20 18.869 1.531 0.0751 14.4.11 D 0.092 23 18.791 1.609 0.0789 14.4.12 D 0.092 22 18.729 1.671 0.0819 14.4.13 D 0.092 23 18.677 1.723 0.0845 14.4.14 D 0.092 19 18.644 1.756 0.0861 14.4.15 D 0.092 19 18.623 1.777 0.0871 14.4.16 D 0.092 21 18.611 1.789 0.0877 END Z 0.000 0 18.611 1.789 0.0877 END Z 0.000 0 18.611 1.789 0.0877 END Z 0.000 0 18.611 1.789 0.0877 END Z 0.000 0 18.611 1.789 0.0877 END Z 0.000 0 18.611 1.789 0.0877 Totals: 1.472 352 CIRCUIT IS WITHIN LIMITS Percent Drop: 8.77% Current: 1.472 Point to Point Method Distance: 352 Voltage Drop: End of Line Voltage: 18.61 1.79 CIRCUIT IS WITHIN LIMITS Percent Drop: 7.80% Load Centering Method Current: 1.472 352 18.81 Distance: Voltage Drop: End of Line Voltage: 1.59 CIRCUIT IS WITHIN LIMITS Percent Drop: 15.60% Current: 1.472 End of Line Method Distance: 352 Voltage Drop: End of Line Voltage: 17.22 3.18 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP14 Battery Calculations Standy Circuit / Device Current Alarm Current Qty Total Standy Current Total Alarm Current Power Supply 70 70 1 70 70 NAC Power NAC1 0 1470 1 0 1470 NAC2 0 1225 1 0 1225 NAC3 0 1470 1 0 1470 NAC4 96 1472 1 96 0 200 mA Aux Power Aux 0 0 0 0 0 Aux 0 0 0 0 0 Aux 0 0 0 0 0 TOTALS: 166 4235 Total Standy Current (Amps): 0.166 X 24 Hours: 3.984 Amphours in Standy Total Alarm Current (Amps): 4.235 X 15 Mins: 1.06 Amphours in Alarm 5.04 Required Amphours Required Amphours: +20% Safety 5.04 6.05 Total Margin Am hours P (2) 12V 8Ah Batteries Required. *Magnetic Door Holders are not included in the battery calculations. Power to these devices will be automatically disconnected upon loss of A/C power to reduce battery size. DEVICE LEGEND Devices Current (Milliamps) Designator Part Number Description Light Ouput 0 15cd 30cd 75cd 95cd 110cd 177cd A B C D E F G H 1 J K L M N 0 P Q R S T U V W X Y SB4U SB4U-LF GSA-SBT SIGA-AB4G-LF INT-7ATW INT-8ATW EG1F-HD EG1F-VM EG1F-HDVM EGCF-VM EGCF-VMH EGCF-HDVM EGCF-HDVMH G4LFWF-H G4LFWF-HVM G4HFWF-S7VMC GCHFWF-S7VMC INT-4ASW XXXX DHF -24120C C01224T XXXX XXXX )(XXX XXXX Sounder Base for V Series Detectors 520Hz Sounder Base for V Series Detectors Sounder Base for PCOS Detectors 520Hz Sounder Base for PCOS Detectors WP Wall Mount Horn/Strobe WP Wall Mount Horn/Strobe Wall Mount Horn Wall Mount Strobe Wall Mount Horn/Strobe Ceiling Mount Strobe Ceiling Mount High Candela Strobe Ceiling Mount Horn/Strobe Ceiling Mount High Candela Horn/Strobe Wall Mount 520Hz Horn Wall Mount 520Hz Horn/Strobe Wall Mount Speaker/Strobe Ceiling Mount Speaker/Strobe Weatherproof Speaker/Strobe XXXX Magnetic Door Hold -Open Carbon Monoxide Detector XXXX XXXX XXXX XXXX 28 92 52 92 180 90 22 85 102 127 135 245 285 160 246 309 94 140 273 325 333 551 111 152 281 333 324 554 166 219 266 381 437 78 101 188 245 94 140 273 325 551 159 15 75 Z N/A END OF CIRCUIT Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP15 Circuit: NAC1 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.225 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms / 1000' 11 14 3.07 93 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 15.1.1 P 110 0.245 11 20.317 0.083 0.0041 15.1.2 P 110 0.245 27 20.155 0.245 0.0120 15.1.3 P 110 0.245 27 20.033 0.367 0.0180 15.1.4 P 110 0.245 9 20.006 0.394 0.0193 15.1.5 P 110 0.245 30 19.961 0.439 0.0215 END Z 0.000 0 19.961 0.439 0.0215 END Z 0.000 0 19.961 0.439 0.0215 END Z 0.000 0 19.961 0.439 0.0215 END Z 0.000 0 19.961 0.439 0.0215 END Z 0.000 0 19.961 0.439 0.0215 END Z 0.000 0 19.961 0.439 0.0215 END Z 0.000 0 19.961 0.439 0.0215 END Z 0.000 0 19.961 0.439 0.0215 END Z 0.000 0 19.961 0.439 0.0215 END Z 0.000 0 19.961 0.439 0.0215 END Z 0.000 0 19.961 0.439 0.0215 END Z 0.000 0 19.961 0.439 0.0215 END Z 0.000 0 19.961 0.439 0.0215 END Z 0.000 0 19.961 0.439 0.0215 END Z 0.000 0 19.961 0.439 0.0215 END Z 0.000 0 19.961 0.439 0.0215 Totals: 1.225 104 CIRCUIT IS WITHIN LIMITS Percent Drop: 2.15% Current: 1.225 Point to Point Method Distance: 104 End of Line Voltage: 19.96 Voltage Drop: 0.44 CIRCUIT IS WITHIN LIMITS Percent Drop: 1.92% Load Centering Method Current: 1.225 H Distance:1 104 20.01 End of Line Voltage: Voltage Drop: 0.39 End of Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 3.83% Current: 1.225 Distance: 104 19.62 End of Line Voltage: Voltage Drop: 0.78 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP15 Circuit: NAC2 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0.491 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 7 14 3.07 237 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 15.2.1 P 30 0.101 7 20.379 0.021 0.0010 15.2.2 P 15 0.078 24 20.321 0.079 0.0039 15.2.3 P 15 0.078 52 20.222 0.178 0.0087 15.2.4 P 15 0.078 55 20.143 0.257 0.0126 15.2.5 P 15 0.078 52 20.093 0.307 0.0150 15.2.6 P 15 0.078 54 20.067 0.333 0.0163 END Z 0.000 0 20.067 0.333 0.0163 END Z 0.000 0 20.067 0.333 0.0163 END Z 0.000 0 20.067 0.333 0.0163 END Z 0.000 0 20.067 0.333 0.0163 END Z 0.000 0 20.067 0.333 0.0163 END Z 0.000 0 20.067 0.333 0.0163 END Z 0.000 0 20.067 0.333 0.0163 END Z 0.000 0 20.067 0.333 0.0163 END Z 0.000 0 20.067 0.333 0.0163 END Z 0.000 0 20.067 0.333 0.0163 END Z 0.000 0 20.067 0.333 0.0163 END Z 0.000 0 20.067 0.333 0.0163 END Z 0.000 0 20.067 0.333 0.0163 END Z 0.000 0 20.067 0.333 0.0163 END Z 0.000 0 20.067 0.333 0.0163 Totals: 0.491 244 CIRCUIT IS WITHIN LIMITS Percent Drop: 1.63% Point to Point Method Current: 0.491 Distance: 244 Voltage Drop: End of Line Voltage: 20.07 0.33 CIRCUIT IS WITHIN LIMITS Load Centering Method Current: 0.491 Percent Drop: 1.80% 244 20.03 Distance: Voltage Drop: End of Line Voltage: 0.37 CIRCUIT IS WITHIN LIMITS Percent Drop: 3.61% End of Line Method Current: 0.491 244 19.66 Distance: Voltage Drop: End of Line Voltage: 0.74 Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP15 Circuit: NAC3 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms / 1000' 0 14 3.07 0 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 Totals: 0 0 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 Point to Point Method Distance: 0 Voltage Drop: End of Line Voltage: 20.40 0.00 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 Load Centering Method Distance: End Line Voltage: 0 Voltage Drop: 0.00 of 20.40 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 End of Line Method 0 20.40 Distance: Voltage Drop: End of Line Voltage: 0.00 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP15 Circuit: NAC4 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.012 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guage Ohms/ 1000' 15 14 3.07 230 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 15.4.1 D 0.092 15 20.307 0.093 0.0046 15.4.2 D 0.092 19 20.199 0.201 0.0098 15.4.3 D 0.092 29 20.052 0.348 0.0171 15.4.4 D 0.092 21 19.957 0.443 0.0217 15.4.5 D 0.092 15 19.898 0.502 0.0246 15.4.6 D 0.092 27 19.806 0.594 0.0291 15.4.7 D 0.092 19 19.753 0.647 0.0317 15.4.8 D 0.092 25 19.696 0.704 0.0345 15.4.9 D 0.092 27 19.650 0.750 0.0367 15.4.10 D 0.092 24 19.623 0.777 0.0381 15.4.11 D 0.092 24 19.610 0.790 0.0387 END Z 0.000 0 19.610 0.790 0.0387 END Z 0.000 0 19.610 0.790 0.0387 END Z 0.000 0 19.610 0.790 0.0387 END Z 0.000 0 19.610 0.790 0.0387 END Z 0.000 0 19.610 0.790 0.0387 END Z 0.000 0 19.610 0.790 0.0387 END Z 0.000 0 19.610 0.790 0.0387 END Z 0.000 0 19.610 0.790 0.0387 END Z 0.000 0 19.610 0.790 0.0387 END Z 0.000 0 19.610 0.790 0.0387 Totals: 1.012 245 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 3.87% Current: 1.012 Distance: 245 Voltage Drop: End of Line Voltage: 19.61 0.79 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 3.73% Current: 1.012 245 19.64 Distance: Voltage Drop: End of Line Voltage: 0.76 CIRCUIT IS WITHIN LIMITS Percent Drop: 7.46% Current: 1.012 End of Line Method 245 18.88 Distance: Voltage Drop: End of Line Voltage: 1.52 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP15 Battery Calculations Standy Circuit / Device Current Alarm Current Qty Total Standy Current Total Alarm Current Power Supply 70 70 1 70 70 NAC Power NAC1 0 1225 1 0 1225 NAC2 0 491 1 0 491 NAC3 0 0 0 0 0 NAC4 66 1012 1 66 0 200 mA Aux Power Aux 0 0 0 0 0 Aux 0 0 0 0 0 Aux 0 0 0 0 0 TOTALS: 136 1786 Total Standy Current (Amps): 0.136 X 24 Hours: 3.264 Amphours in Standy Total Alarm Current (Amps): 1.786 X 15 Mins: 0.45 Amphours in Alarm 3.71 Required Amphours +20% Safety Tota! Required Amphours: 3.71 Margin 4.45 Amphours (2) 12V 8Ah Batteries Required. *Magnetic Door Holders are not included in the battery calculations. Power to these devices will be automatically disconnected upon loss of NC power to reduce battery size. DEVICE LEGEND Devices Current (Milliamps) Designator Part Number Description Light Ouput 0 15cd 30cd 75cd 95cd 110cd 177cd A B C D E F G H I J K L M N 0 P Q R S T U V W X Y SB4U SB4U-LF GSA-SBT SIGA-AB4G-LF INT-7ATW INT-8ATW EG1F-HD EG1F-VM EG1F-HDVM EGCF-VM EGCF-VMH EGCF-HDVM EGCF-HDVMH G4LFWF-H G4LFWF-HVM G4HFWF-S7VMC GCHFWF-S7VMC INT-4ASW XXXX DHF -24120C C01224T XXXX XXXX XXXX XXXX Sounder Base for V Series Detectors 520Hz Sounder Base for V Series Detectors Sounder Base for PCOS Detectors 520Hz Sounder Base for PCOS Detectors WP Wall Mount Horn/Strobe WP Wall Mount Horn/Strobe Wall Mount Horn Wall Mount Strobe Wall Mount Horn/Strobe Ceiling Mount Strobe Ceiling Mount High Candela Strobe Ceiling Mount Horn/Strobe Ceiling Mount High Candela Horn/Strobe Wall Mount 520Hz Horn Wall Mount 520Hz Horn/Strobe Wall Mount Speaker/Strobe Ceiling Mount Speaker/Strobe Weatherproof Speaker/Strobe XXXX Magnetic Door Hold -Open Carbon Monoxide Detector XXXX XXXX XXXX XXXX 28 92 52 92 180 90 22 85 127 245 285 102 135 160 246 309 94 140 273 325 333 551 111 152 281 333 324 554 166 219 266 381 437 78 101 188 245 94 140 273 325 551 159 15 75 Z N/A END OF CIRCUIT Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP16 Circuit: NAC1 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.715 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 165 14 3.07 96 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 16.1.1 P 110 0.245 165 18.663 1.737 0.0852 16.1.2 P 110 0.245 19 18.491 1.909 0.0936 16.1.3 P 110 0.245 18 18.356 2.044 0.1002 16.1.4 P 110 0.245 9 18.302 2.098 0.1029 16.1.5 P 110 0.245 34 18.148 2.252 0.1104 16.1 .6 P 110 0.245 9 18.121 2.279 0.1117 16.1.7 P 110 0.245 7 18.110 2.290 0.1122 END Z 0.000 0 18.110 2.290 0.1122 END Z 0.000 0 18.110 2.290 0.1122 END Z 0.000 0 18.110 2.290 0.1122 END Z 0.000 0 18.110 2.290 0.1122 END Z 0.000 0 18.110 2.290 0.1122 END Z 0.000 0 18.110 2.290 0.1122 END Z 0.000 0 18.110 2.290 0.1122 END Z 0.000 0 18.110 2.290 0.1122 END Z 0.000 0 18.110 2.290 0.1122 END Z 0.000 0 18.110 2.290 0.1122 END Z 0.000 0 18.110 2.290 0.1122 END Z 0.000 0 18.110 2.290 0.1122 END Z 0.000 0 18.110 2.290 0.1122 END Z 0.000 0 18.110 2.290 0.1122 Totals: 1.715 261 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 11.22% Current: 1.715 261 Distance: Voltage Drop: End of Line Voltage: 18.11 2.29 CIRCUIT IS WITHIN LIMITS Percent Drop: 6.74% Current: 1.715 Load Centering Method Distance: End Line Voltage: 261 19.03 Voltage Drop:; 1.37 of CIRCUIT IS WITHIN LIMITS Percent Drop: 13.47% Current: 1.715 End of Line Method Distance: End Line Voltage: 261 17.65 Voltage Drop: 2.75 of Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP16 Circuit: NAC2 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 2.13 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 41 14 3.07 131 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 16.2.1 P 110 0.245 41 19.864 0.536 0.0263 16.2.2 P 110 0.245 9 19.760 0.640 0.0314 16.2.3 H 15 0.085 20 19.558 0.842 0.0413 16.2.4 P 110 0.245 12 19.444 0.956 0.0469 16.2.5 P 110 0.245 9 19.371 1.029 0.0504 16.2.6 P 110 0.245 6 19.332 1.068 0.0524 16.2.7 H 15 0.085 8 19.292 1.108 0.0543 16.2.8 P 110 0.245 51 19.062 1.338 0.0656 16.2.9 P 110 0.245 7 19.041 1.359 0.0666 16.2.10 P 110 0.245 9 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 Totals: 2.13 172 CIRCUIT IS WITHIN LIMITS Percent Drop: 6.73% Current: 2.13 Point to Point Method 172 19.03 Distance: Voltage Drop: End of Line Voltage: 1.37 CIRCUIT IS WITHIN LIMITS Percent Drop: 5.51% Load Centering Method Current: 2.13 172 19.28 Distance: Voltage Drop: End of Line Voltage: 1.12 CIRCUIT IS WITHIN LIMITS Percent Drop: 11.03% End of Line Method Current: 2.13 172 18.15 Distance: Voltage Drop: End of Line Voltage: 2.25 Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP16 Circuit: NAC3 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.8 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 48 14 3.07 123 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 16.3.1 P 110 0.245 48 19.870 0.530 0.0260 16.3.2 P 110 0.245 9 19.784 0.616 0.0302 16.3.3 P 110 0.245 22 19.607 0.793 0.0389 16.3.4 H 15 0.085 9 19.548 0.852 0.0418 16.3.5 P 110 0.245 20 19.427 0.973 0.0477 16.3.6 P 110 0.245 22 19.328 1.072 0.0525 16.3.7 P 110 0.245 20 19.268 1.132 0.0555 16.3.8 P 110 0.245 21 19.236 1.164 0.0570 END Z 0.000 0 19.236 1.164 0.0570 END Z 0.000 0 19.236 1.164 0.0570 END Z 0.000 0 19.236 1.164 0.0570 END Z 0.000 0 19.236 1.164 0.0570 END Z 0.000 0 19.236 1.164 0.0570 END Z 0.000 0 19.236 1.164 0.0570 END Z 0.000 0 19.236 1.164 0.0570 END Z 0.000 0 19.236 1.164 0.0570 END Z 0.000 0 19.236 1.164 0.0570 END Z 0.000 0 19.236 1.164 0.0570 END Z 0.000 0 19.236 1.164 0.0570 END Z 0.000 0 19.236 1.164 0.0570 END Z 0.000 0 19.236 1.164 0.0570 Totals: 1.8 171 CIRCUIT IS WITHIN LIMITS Percent Drop: 5.70% Current: 1.8 Point to Point Method Distance: 171 Voltage Drop: End of Line Voltage: 19.24 1.16 CIRCUIT IS WITHIN LIMITS Percent Drop: 4.63% Current: 1.8 Load Centering Method Distance: End Line Voltage: 171 Voltage Drop: 0.94 of 19.46 CIRCUIT IS WITHIN LIMITS Percent Drop: 9.26% Current: 1.8 End of Line Method Distance: End Line Voltage: 171 18.51 Voltage Drop: 1.89 of Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP16 Circuit: NAC4 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.472 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000` 41 14 3.07 312 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 16.4.1 D 0.092 41 20.029 0.371 0.0182 16.4.2 D 0.092 27 19.801 0.599 0.0294 16.4.3 D 0.092 16 19.674 0.726 0.0356 16.4.4 D 0.092 20 19.527 0.873 0.0428 16.4.5 D 0.092 26 19.351 1.049 0.0514 16.4.6 D 0.092 20 19.227 1.173 0.0575 16.4.7 D 0.092 22 19.102 1.298 0.0636 16.4.8 D 0.092 20 19.001 1.399 0.0686 16.4.9 D 0.092 21 18.906 1.494 0.0732 16.4.10 D 0.092 22 18.819 1.581 0.0775 16.4.11 D 0.092 19 18.755 1.645 0.0807 16.4.12 D 0.092 23 18.690 1.710 0.0838 16.4.13 D 0.092 21 18.642 1.758 0.0862 16.4.14 D 0.092 12 18.622 1.778 0.0872 16.4.15 D 0.092 23 18.596 1.804 0.0884 16.4.16 D 0.092 20 18.584 1.816 0.0890 END Z 0.000 0 18.584 1.816 0.0890 END Z 0.000 0 18.584 1.816 0.0890 END Z 0.000 0 18.584 1.816 0.0890 END Z 0.000 0 18.584 1.816 0.0890 END Z 0.000 0 18.584 1.816 0.0890 Totals: 1.472 353 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 8.90% Current: 1.472 Distance: 353 Voltage Drop: End of Line Voltage: 18.58 1.82 CIRCUIT IS WITHIN LIMITS Percent Drop: 7.82% Current: 1.472 Load Centering Method Distance: 353 Voltage Drop: End of Line Voltage: 18.80 1.60 End of Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 15.64% Current: 1.472 Distance: 353 Voltage Drop: End of Line Voltage: 17.21 3.19 Prosect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP16 Battery Calculations Standy Circuit / Device Current Alarm Current Qty Total Standy Current Total Alarm Current Power Supply 70 70 1 70 70 NAC Power NAC1 0 1715 1 0 1715 NAC2 0 2130 1 0 2130 NAC3 0 1800 1 0 1800 NAC4 96 1472 1 96 0 200 mA Aux Power Aux 0 0 0 0 0 Aux 0 0 0 0 0 Aux 0 0 0 0 0 TOTALS: 166 5715 Total Standy Current (Amps): 0.166 X 24 Hours: 3.984 Amphours in Standy Total Alarm Current (Amps): 5.715 X 15 Mins: 1.43 Amphours in Alarm 5.41 Required Amphours Required Amphours: 5.41 +20% Safety 6.50 Margin Total Amphours (2) 12V 8Ah Batteries Required. *Magnetic Door Holders are not included in the battery calculations. Power to these devices will be automatically disconnected upon loss of NC power to reduce battery size. DEVICE LEGEND Devices Current (Milliamps) Designator Part Number Description Light Ouput 0 15cd 30cd 75cd 95cd 110cd 177cd A B C D E F G H I J K L SB4U SB4U-LF GSA-SBT SIGA-AB4G-LF INT-7ATW INT-8ATW EG1F-HD EG1F-VM EG1F-HDVM EGCF-VM EGCF-VMH EGCF-HDVM Sounder Base for V Series Detectors 520Hz Sounder Base for V Series Detectors Sounder Base for PCOS Detectors 520Hz Sounder Base for PCOS Detectors WP Wall Mount Horn/Strobe WP Wall Mount Horn/Strobe Wall Mount Horn Wall Mount Strobe Wall Mount Horn/Strobe Ceiling Mount Strobe Ceiling Mount High Candela Strobe Ceiling Mount Horn/Strobe 28 92 52 92 180 90 22 85 127 245 285 309 102 135 160 246 94 140 273 325 333 551 - 111 152 281 333 -� M N 0 P Q R S T U V W X Y EGCF-HDVMH G4LFWF-H G4LFWF-HVM G4HFWF-S7VMC GCHFWF-S7VMC INT-4ASW XXXX DHF-24120C C01224T XXXX XXXX )(XXX XXXX Ceiling Mount High Candela Horn/Strobe Wall Mount 520Hz Horn Wall Mount 520Hz Horn/Strobe Wall Mount Speaker/Strobe Ceiling Mount Speaker/Strobe Weatherproof Speaker/Strobe XXXX Magnetic Door Hold-Open Carbon Monoxide Detector XXXX XXXX XXXX XXXX --- 324 .. 219 266 381 437 78 101 188 245 94 140 273 325 551 159 15 75 Z N/A END OF CIRCUIT Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP17 Circuit: NAC1 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0.468 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 15 14 3.07 223 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 17.1.1 P 15 0.078 15 20.357 0.043 0.0021 17.1.2 P 15 0.078 10 20.333 0.067 0.0033 17.1.3 P 15 0.078 52 20.233 0.167 0.0082 17.1.4 P 15 0.078 55 20.154 0.246 0.0120 17.1.5 P 15 0.078 52 20.105 0.295 0.0145 17.1.6 P 15 0.078 54 20.079 0.321 0.0158 END Z 0.000 0 20.079 0.321 0.0158 END Z 0.000 0 20.079 0.321 0.0158 END Z 0.000 0 20.079 0.321 0.0158 END Z 0.000 0 20.079 0.321 0.0158 END Z 0.000 0 20.079 0.321 0.0158 END Z 0.000 0 20.079 0.321 0.0158 END Z 0.000 0 20.079 0.321 0.0158 END Z 0.000 0 20.079 0.321 0.0158 END Z 0.000 0 20.079 0.321 0.0158 END Z 0.000 0 20.079 0.321 0.0158 END Z 0.000 0 20.079 0.321 0.0158 END Z 0.000 0 20.079 0.321 0.0158 END Z 0.000 0 20.079 0.321 0.0158 END Z 0.000 0 20.079 0.321 0.0158 END Z 0.000 0 20.079 0.321 0.0158 Totals: 0.468 238 CIRCUIT IS WITHIN LIMITS Percent Drop: 1.58% Current: 0.468 Point to Point Method End Line Voltage: Distance: 238 Voltage Drop: 0.32 of 20.08 CIRCUIT IS WITHIN LIMITS Load Centering Method Percent Drop: 1.68% Current: 0.468 Distance: 238 End Line Voltage Drop: 0.34 of Voltage: 20.06 End of Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 3.35% Current: 0.468 Distance: 238 19.72 End Line Voltage: Volta 9 a Dro 0.68 p:; of Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP17 Circuit: NAC2 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.225 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000° 147 14 3.07 74 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 17.2.1 P 110 0.245 147 19.294 1.106 0.0542 17.2.2 P 110 0.245 16 19.198 1.202 0.0589 17.2.3 P 110 0.245 19 19.112 1.288 0.0631 17.2.4 P 110 0.245 18 19.058 1.342 0.0658 17.2.5 P 110 0.245 21 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0,000 0 19.027 1.373 0.0673 Totals: 1.225 221 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 6.73% Current: 1.225 Distance: 221 End Line Voltage: 19.03 Voltage Drop: 1.37 of CIRCUIT IS WITHIN LIMITS Percent Drop: 4.07% Load Centering Method Current: 1.225 221 19.57 Distance: Voltage Drop: End of Line Voltage: 0.83 CIRCUIT IS WITHIN LIMITS Percent Drop: 8.15% End of Line Method Current: 1.225 221 18.74 Distance: Voltage Drop: End of Line Voltage: 1.66 Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP17 Circuit: NAC3 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.31 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 65 14 3.07 102 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 17.3.1 P 110 0.245 65 19.877 0.523 0.0256 17.3.2 P 110 0.245 33 19.661 0.739 0.0362 17.3.3 P 110 0.245 9 19.616 0.784 0.0384 17.3.4 P 110 0.245 29 19.514 0.886 0.0434 17.3.5 H 15 0.085 8 19.497 0.903 0.0442 17.3.6 P 110 0.245 23 19.463 0.937 0.0459 END Z 0.000 0 19.463 0.937 0.0459 END Z 0.000 0 19.463 0.937 0.0459 END Z 0.000 0 19.463 0.937 0.0459 END Z 0.000 0 19.463 0.937 0.0459 END Z 0.000 0 19.463 0.937 0.0459 END Z 0.000 0 19.463 0.937 0.0459 END Z 0.000 0 19.463 0.937 0.0459 END Z 0.000 0 19.463 0.937 0.0459 END Z 0.000 0 19.463 0.937 0.0459 END Z 0.000 0 19.463 0.937 0.0459 END Z 0.000 0 19.463 0.937 0.0459 END Z 0.000 0 19.463 0.937 0.0459 END Z 0.000 0 19.463 0.937 0.0459 END Z 0.000 0 19.463 0.937 0.0459 END Z 0.000 0 19.463 0.937 0.0459 Totals: 1.31 167 CIRCUIT IS WITHIN LIMITS Percent Drop: 4.59% Current: 1.31 Point to Point Method Distance: 167 Voltage Drop: End of Line Voltage: 19.46 0.94 CIRCUIT IS WITHIN LIMITS Percent Drop: 3.29% Current: 1.31 Load Centering Method Distance: End Line Voltage: 167 19.73 Voltage Drop: 0.67 of CIRCUIT IS WITHIN LIMITS Percent Drop: 6.58% Current: 1.31 End of Line Method Distance: End Line Voltage: 167 19.06 Voltage Drop: 1.34 of Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP17 Circuit: NAC4 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.472 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 71 14 3.07 302 14 3.07 Low Frequency Device Device Address Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 17.4.1 D 0.092 71 19.758 0.642 0.0315 17.4.2 D 0.092 20 19.589 0.811 0.0398 17.4.3 D 0.092 19 19.439 0.961 0.0471 17.4.4 D 0.092 20 19.292 1.108 0.0543 17.4.5 D 0.092 17 19.176 1.224 0.0600 17.4.6 D 0.092 21 19.046 1.354 0.0664 17.4.7 D 0.092 18 18.944 1.456 0.0714 17.4.8 D 0.092 23 18.827 1.573 0.0771 17.4.9 D 0.092 19 18.742 1.658 0.0813 17.4.10 D 0.092 19 18.666 1.734 0.0850 17.4.11 D 0.092 25 18.582 1.818 0.0891 17.4.12 D 0.092 17 18.534 1.866 0.0915 17.4.13 D 0.092 25 18.477 1.923 0.0943 17.4.14 D 0.092 19 18.445 1.955 0.0958 17.4.15 D 0.092 19 18.423 1.977 0.0969 17.4.16 D 0.092 21 18.412 1.988 0.0975 END Z 0.000 0 18.412 1.988 0.0975 END Z 0.000 0 18.412 1.988 0.0975 END Z 0.000 0 18.412 1.988 0.0975 END Z 0.000 0 18.412 1.988 0.0975 END Z 0.000 0 18.412 1.988 0.0975 Totals: 1.472 373 CIRCUIT IS WITHIN LIMITS Percent Drop: 9.75% Current: 1.472 Point to Point Method Distance: 373 End Line Voltage: 18.41 Voltage Drop: 1.99 of CIRCUIT IS WITHIN LIMITS Percent Drop: 8.26% Current: 1.472 Load Centering Method Distance: End Line Voltage: 373 18.71 Voltage Drop: 1.69 of CIRCUIT IS WITHIN LIMITS Percent Drop: 16.53% Current: 1.472 End of Line Method Distance: End Line Voltage: 373 17.03 Voltage Drop: 3.37 of Proiect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP17 Battery Calculations Circuit / Device Standy Current Alarm Current Qty Total Standy Current Total Alarm Current Power Supply 70 70 1 70 70 NAC Power NAC1 0 468 1 0 468 NAC2 0 1225 1 0 1225 NAC3 0 1310 1 0 1310 NAC4 96 1472 1 96 0 200 mA Aux Power Aux 0 0 0 0 0 Aux 0 0 0 0 0 Aux 0 0 0 0 0 TOTALS: 166 3073 Total Standy Current (Amps): 0.166 X 24 Hours: 3.984 Amphours in Standy Total Alarm Current (Amps): 3.073 X 15 Mins: 0.77 Amphours in Alarm 4.75 Required Amphours +20% Safety Total Required Amphours: 4.75 Margin 5'70 hours Amphours (2) 12V 8Ah Batteries Required. *Magnetic Door Holders are not included in the battery calculations. Power to these devices will be automatically disconnected upon loss of NC power to reduce battery size. DEVICE LEGEND Devices Current (Milliamps) Designator Part Number Description Light ouput 0 15cd 30cd 75cd 95cd 110cd 177cd A B C D E F G H J K L M N 0 P Q R S T U V W X Y SB4U SB4U-LF GSA-SBT SIGA-AB4G-LF INT-7ATW INT-8ATW EG1F-HD EG1F-VM EG1F-HDVM EGCF-VM EGCF-VMH EGCF-HDVM EGCF-HDVMH G4LFWF-H G4LFWF-HVM G4HFWF-S7VMC GCHFWF-S7VMC INT-4ASW XXXX DHF-24120C CO1224T XXXX XXXX XXXX XXXX Sounder Base for V Series Detectors 520Hz Sounder Base for V Series Detectors Sounder Base for PCOS Detectors 520Hz Sounder Base for PCOS Detectors WP Wall Mount Horn/Strobe WP Wall Mount Horn/Strobe Wall Mount Horn Wall Mount Strobe Wall Mount Horn/Strobe Ceiling Mount Strobe Ceiling Mount High Candela Strobe Ceiling Mount Horn/Strobe Ceiling Mount High Candela Horn/Strobe Wall Mount 520Hz Horn Wall Mount 520Hz Horn/Strobe Wall Mount Speaker/Strobe Ceiling Mount Speaker/Strobe Weatherproof Speaker/Strobe XXXX Magnetic Door Hold-Open Carbon Monoxide Detector XXXX XXXX XXXX XXXX 28 92 52 92 180 90 22 85 127 245 285 309 102 135 160 246 94 140 273 325 333 551 111 152 281 333 324 554 166 219 266 381 437 78 101 188 245 94 140 273 325 551 159 15 75 Z N/A END OF CIRCUIT Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP18 Circuit: NAC1 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.47 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 34 14 3.07 103 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 18.1.1 18.1.2 18.1.3 18.1.4 18.1.5 18.1.6 END END END END END END END END END END END END END END END P 110 P 110 P 110 P 110 P 110 P 110 Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Totals: 0.245 34 0.245 19 0.245 23 0.245 19 0.245 22 0.245 20 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 1.47 137 20.093 0.307 19.950 0.450 19.812 0.588 19.726 0.674 19.660 0.740 19.630 0.770 19.630 0.770 19.630 0.770 19.630 0.770 19.630 0.770 19.630 0.770 19.630 0.770 19.630 0.770 19.630 0.770 19.630 0.770 19.630 0.770 19.630 0.770 19.630 0.770 19.630 0.770 19.630 0.770 19.630 0.770 0.0150 0.0220 0.0288 0.0330 0.0363 0.0378 0.0378 0.0378 0.0378 0.0378 0.0378 0.0378 0.0378 0.0378 0.0378 0.0378 0.0378 0.0378 0.0378 0.0378 0.0378 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: End of Line Voltage: 3.78% Current: 1.47 Distance:1 137 19.63 Voltage Drop: 0.77 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: End of Line Voltage: 3.03% Current:! 1.47 Distance: 137 19.78 Voltage Drop: 0.62 End of Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: End of Line Voltage: 6.06% Current: 1.47 Distance: 137 19.16 Voltage Drop: 1.24 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP18 Circuit: NAC2 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0.592 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000° 5 14 3.07 219 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 18.2.1 P 30 0.101 5 20.382 0.018 0.0009 18.2.2 P 15 0.078 8 20.358 0.042 0.0021 18.2.3 P 30 0.101 29 20.284 0.116 0.0057 18.2.4 P 15 0.078 30 20.227 0.173 0.0085 18.2.5 P 15 0.078 52 20.152 0.248 0.0122 18.2.6 P 15 0.078 50 20.104 0.296 0.0145 18.2.7 P 15 0.078 50 20.080 0.320 0.0157 END Z 0.000 0 20.080 0.320 0.0157 END Z 0.000 0 20.080 0.320 0.0157 END Z 0.000 0 20.080 0.320 0.0157 END Z 0.000 0 20.080 0.320 0.0157 END Z 0.000 0 20.080 0.320 0.0157 END Z 0.000 0 20.080 0.320 0.0157 END Z 0.000 0 20.080 0.320 0.0157 END Z 0.000 0 20.080 0.320 0.0157 END Z 0.000 0 20.080 0.320 0.0157 END Z 0.000 0 20.080 0.320 0.0157 END Z 0.000 0 20.080 0.320 0.0157 END Z 0.000 0 20.080 0.320 0.0157 END Z 0.000 0 20.080 0.320 0.0157 END Z 0.000 0 20.080 0.320 0.0157 Totals: 0.592 224 CIRCUIT IS WITHIN LIMITS Point to Point Method Percent Drop: 1.57% Current: 0.592 224 20.08 Distance: Voltage Drop: End of Line Voltage: 0.32 CIRCUIT IS WITHIN LIMITS Percent Drop: 2.00% Load Centering Method Current: 0.592 224 19.99 Distance: Voltage Drop: End of Line Voltage: 0.41 CIRCUIT IS WITHIN LIMITS Percent Drop: 3.99% Current: 0.592 End of Line Method 224 19.59 Distance: Voltage Drop: End of Line Voltage: 0.81 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP18 Circuit: NAC3 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.225 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 152 14 3.07 77 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 18.3.1 P 110 0.245 152 19.257 1.143 0.0560 18.3.2 P 110 0.245 19 19.142 1.258 0.0616 18.3.3 P 110 0.245 9 19.102 1.298 0.0636 18.3.4 P 110 0.245 40 18.981 1.419 0.0695 18.3.5 P 110 0.245 9 18.968 1.432 0.0702 END Z 0.000 0 18.968 1.432 0.0702 END Z 0.000 0 18.968 1.432 0.0702 END Z 0.000 0 18.968 1.432 0.0702 END Z 0.000 0 18.968 1.432 0.0702 END Z 0.000 0 18.968 1.432 0.0702 END Z 0.000 0 18.968 1.432 0.0702 END Z 0.000 0 18.968 1.432 0.0702 END Z 0.000 0 18.968 1.432 0.0702 END Z 0.000 0 18.968 1.432 0.0702 END Z 0.000 0 18.968 1.432 0.0702 END Z 0.000 0 18.968 1.432 0.0702 END Z 0.000 0 18.968 1.432 0.0702 END Z 0.000 0 18.968 1.432 0.0702 END Z 0.000 0 18.968 1.432 0.0702 END Z 0.000 0 18.968 1.432 0.0702 END Z 0.000 0 18.968 1.432 0.0702 Totals: 1.225 229 CIRCUIT IS WITHIN LIMITS Percent Drop: 7.02% Current: 1.225 Point to Point Method Distance: 229 Voltage Drop: End of Line Voltage: 18.97 1.43 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 4.22% Current: 1.225 229 19.54 Distance: Voltage Drop: End of Line Voltage: 0.86 CIRCUIT IS WITHIN LIMITS Percent Drop: 8.44% Current: 1.225 End of Line Method 229 18.68 Distance: Voltage Drop: End of Line Voltage: 1.72 Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP18 Circuit: NAC4 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.012 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 33 14 3.07 212 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 18.4.1 D 0.092 33 20.195 0.205 0.0101 18.4.2 D 0.092 19 20.088 0.312 0.0153 18.4.3 D 0.092 22 19.976 0.424 0.0208 18.4.4 D 0.092 19 19.890 0.510 0.0250 18.4.5 D 0.092 22 19.803 0.597 0.0293 18.4.6 D 0.092 20 19.735 0.665 0.0326 18.4.7 D 0.092 19 19.681 0.719 0.0352 18.4.8 D 0.092 22 19.632 0.768 0.0377 18.4.9 D 0.092 22 19.594 0.806 0.0395 18.4.10 D 0.092 27 19.564 0.836 0.0410 18.4.11 D 0.092 20 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 Totals: 1.012 245 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 4.15% Current: 1.012 Distance: 245 Voltage Drop: End of Line Voltage: 19.55 0.85 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 3.73% Current: 1.012 245 19.64 Distance: Voltage Drop: End of Line Voltage: 0.76 End Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 7.46% Current: 1.012. of Distance: 245 Voltage Drop: End of Line Voltage: 18.88 1.52 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP18 Battery Calculations Circuit / Device Standy Current Alarm Current Qty Total Standy Current Total Alarm Current Power Supply 70 70 1 70 70 NAC Power NAC1 0 1470 1 0 1470 NAC2 0 592 1 0 592 NAC3 0 1225 1 0 1225 NAC4 66 1012 1 66 0 200 mA Aux Power Aux 0 0 0 0 0 Aux 0 0 0 0 0 Aux 0 0 0 0 0 TOTALS: 136 3357 Total Standy Current (Amps): 0.136 X 24 Hours: 3.264 Amphours in Standy Total Alarm Current (Amps): 3.357 X 15 Mins: 0.84 Amphours in Alarm 4.10 Required Amphours +20% Safety Total Required Amphours: 4.10 Margin 4.92 hours Amphours (2) 12V 8Ah Batteries Required. *Magnetic Door Holders are not included in the battery calculations. Power to these devices will be automatically disconnected upon Toss of NC power to reduce battery size. DEVICE LEGEND Devices Current (Milliamps) Designator Part Number Description Light Ouput 0 15cd 30cd 75cd 95cd 110cd 177cd A B C D E F G H I J K L M N 0 P Q R S T U V W X Y SB4U SB4U-LF GSA-SBT SIGA-AB4G-LF INT-7ATW INT-8ATW EG1F-HD EG1F-VM EG1F-HDVM EGCF-VM EGCF-VMH EGCF-HDVM EGCF-HDVMH G4LFWF-H G4LFWF-HVM G4HFWF-S7VMC GCHFWF-S7VMC INT-4ASW XXXX DHF -24120C C01224T XXXX XXXX XXXX XXXX Sounder Base for V Series Detectors 520Hz Sounder Base for V Series Detectors Sounder Base for PCOS Detectors 520Hz Sounder Base for PCOS Detectors WP Wall Mount Horn/Strobe WP Wall Mount Horn/Strobe Wall Mount Horn Wall Mount Strobe Wall Mount Horn/Strobe Ceiling Mount Strobe Ceiling Mount High Candela Strobe Ceiling Mount Horn/Strobe Ceiling Mount High Candela Horn/Strobe Wall Mount 520Hz Horn Wall Mount 520Hz Horn/Strobe Wall Mount Speaker/Strobe Ceiling Mount Speaker/Strobe Weatherproof Speaker/Strobe XXXX Magnetic Door Hold -Open Carbon Monoxide Detector XXXX )(XXX XXXX XXXX 28 92 52 92 180 90 22 85 127 135 245 285 102 160 246 309 94 140 273 325 333 551 111 152 281 333 324 554 166 219 266 381 437 78 101 188 245 94 140 273 325 551 159 15 75 Z N/A END OF CIRCUIT Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP19 Circuit: NAC1 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.225 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 12 14 3.07 88 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 19.1.1 P 110 0.245 12 20.310 0.090 0.0044 19.1.2 P 110 0.245 25 20.159 0.241 0.0118 19.1.3 P 110 0.245 23 20.056 0.344 0.0169 19.1.4 P 110 0.245 9 20.028 0.372 0.0182 19.1.5 P 110 0.245 31 19.982 0.418 0.0205 END Z 0.000 0 19.982 0.418 0.0205 END Z 0.000 0 19.982 0.418 0.0205 END Z 0.000 0 19.982 0.418 0.0205 END Z 0.000 0 19.982 0.418 0.0205 END Z 0.000 0 19.982 0.418 0.0205 END Z 0.000 0 19.982 0.418 0.0205 END Z 0.000 0 19.982 0.418 0.0205 END Z 0.000 0 19.982 0.418 0.0205 END Z 0.000 0 19.982 0.418 0.0205 END Z 0.000 0 19.982 0.418 0.0205 END Z 0.000 0 19.982 0.418 0.0205 END Z 0.000 0 19.982 0.418 0.0205 END Z 0.000 0 19.982 0.418 0.0205 END Z 0.000 0 19.982 0.418 0.0205 END Z 0.000 0 19.982 0.418 0.0205 END Z 0.000 0 19.982 0.418 0.0205 Totals: 1.225 100 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 2.05% Current: 1.225 Distance: 100 Voltage Drop: End of Line Voltage: 19.98 0.42 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 1.84% Current: 1.225 100 Distance:1 Volta 9 a Dro p: End of Line Voltage: 20.02 0.38 End Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 3.69% Current:! 1.225 of Distance: 100 Voltage Drop: End of Line Voltage: 19.65 j 0.75 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP19 Circuit: NAC2 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.47 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000` 102 14 3.07 115 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 19.2.1 P 110 0.245 102 19.479 0.921 0.0451 19.2.2 P 110 0.245 21 19.321 1.079 0.0529 19.2.3 P 110 0.245 22 19.189 1.211 0.0594 19.2.4 P 110 0.245 32 19.045 1.355 0.0664 19.2.5 P 110 0.245 16 18.996 1.404 0.0688 19.2.6 P 110 0.245 24 18.960 1.440 0.0706 END Z 0.000 0 18.960 1.440 0.0706 END Z 0.000 0 18.960 1.440 0.0706 END Z 0.000 0 18.960 1.440 0.0706 END Z 0.000 0 18.960 1.440 0.0706 END Z 0.000 0 18.960 1.440 0.0706 END Z 0.000 0 18.960 1.440 0.0706 END Z 0.000 0 18.960 1.440 0.0706 END Z 0.000 0 18.960 1.440 0.0706 END Z 0.000 0 18.960 1.440 0.0706 END Z 0.000 0 18.960 1.440 0.0706 END Z 0.000 0 18.960 1.440 0.0706 END Z 0.000 0 18.960 1.440 0.0706 END Z 0.000 0 18.960 1.440 0.0706 END Z 0.000 0 18.960 1.440 0.0706 END Z 0.000 0 18.960 1.440 0.0706 Totals: 1.47 217 CIRCUIT IS WITHIN LIMITS Percent Drop: 7.06% Current: 1.47 Point to Point Method 217 18.96 Distance: Voltage Drop: End of Line Voltage: 1.44 CIRCUIT IS WITHIN LIMITS Percent Drop: 4.80% Load Centering Method Current: 1.47 217 19.42 Distance: Voltage Drop: End of Line Voltage: 0.98 CIRCUIT IS WITHIN LIMITS Percent Drop: 9.60% End of Line Method Current: 1.47 217 18.44 Distance: Voltage Drop: End of Line Voltage: 1.96 Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP19 Circuit: NAC3 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000" 0 14 3.07 0 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z. 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 Totals: 0 0 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 Point to Point Method Distance: End Line Voltage: 0 Voltage Drop: 0.00 of 20.40 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 0 20.40 Distance: Voltage Drop: End of Line Voltage: 0.00 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 End of Line Method Distance: 0 Voltage Drop: End of Line Voltage: 20.40 0.00 Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP19 Circuit: NAC4 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.012 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Ouaae Ohms/ 1000' 16 14 3.07 229 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 19.4.1 D 0.092 16 20.301 0.099 0.0049 19.4.2 D 0.092 17 20.205 0.195 0.0096 19.4.3 D 0.092 24 20.083 0.317 0.0156 19.4.4 D 0.092 21 19.988 0.412 0.0202 19.4.5 D 0.092 16 19.924 0.476 0.0233 19.4.6 D 0.092 27 19.833 0.567 0.0278 19.4.7 D 0.092 24 19.765 0.635 0.0311 19.4.8 D 0.092 23 19.713 0.687 0.0337 19.4.9 D 0.092 27 19.667 0.733 0.0359 19.4.10 D 0.092 24 19.640 0.760 0.0372 19.4.11 D 0.092 26 19.626 0.774 0.0380 END Z 0.000 0 19.626 0.774 0.0380 END Z 0.000 0 19.626 0.774 0.0380 END Z 0.000 0 19.626 0.774 0.0380 END Z 0.000 0 19.626 0.774 0.0380 END Z 0.000 0 19.626 0.774 0.0380 END Z 0.000 0 19.626 0.774 0.0380 END Z 0.000 0 19.626 0.774 0.0380 END Z 0.000 0 19.626 0.774 0.0380 END Z 0.000 0 19.626 0.774 0.0380 END Z 0.000 0 19.626 0.774 0.0380 Totals: 1.012 245 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 3.80% Current: 1.012 Distance: 245 Voltage Drop: End of Line Voltage: 19.63 0.77 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 3.73% Current: 1.012 245 19.64 Distance: Voltage Drop: End of Line Voltage: 0.76 End Line Method CIRCUIT IS WITHIN LIMITS Percent Drop:7.46% Current: 1.012 of Distance: 245 Voltage Drop: End of Line Voltage: 18.88 1.52 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP19 Battery Calculations Standy Circuit / Device Current Alarm Current 70 Qty Total Standy Current Total Alarm Current Power Supply 70 1 70 70 NAC Power NAC1 0 1225 1 0 1225 NAC2 0 1470 1 0 1470 NAC3 0 0 0 0 0 NAC4 66 1012 1 66 0 200 mA Aux Power Aux 0 0 0 0 0 Aux 0 0 0 0 0 Aux 0 0 0 0 0 TOTALS: 136 2765 Total Standy Current (Amps): 0.136 X 24 Hours: 3.264 Amphours in Standy Total Alarm Current (Amps): 2.765 X 15 Mins: 0.69 Amphours in Alarm 3.96 Required Amphours Required Amphours: +20% Safety 3.96 Margin et' 4.75 Total Amphours (2) 12V 8Ah Batteries Required. *Magnetic Door Holders are not included in the battery calculations. Power to these devices will be automatically disconnected upon Toss of NC power to reduce battery size. DEVICE LEGEND Devices Current (Milliamps) Designator Part Number Description LightOuput 0 15cd 30cd 75cd 95cd 110cd 177cd A B C D E F G H I J K L M N 0 P Q R S T U V W X Y SB4U SB4U-LF GSA-SBT SIGA-AB4G-LF INT-7ATW INT-8ATW EG1F-HD EG1F-VM EG1F-HDVM EGCF-VM EGCF-VMH EGCF-HDVM EGCF-HDVMH G4LFWF-H G4LFWF-HVM G4HFWF-S7VMC GCHFWF-S7VMC INT-4ASW XXXX DHF -24120C C01224T XXXX )(XXX XXXX XXXX Sounder Base for V Series Detectors 520Hz Sounder Base for V Series Detectors Sounder Base for PCOS Detectors 520Hz Sounder Base for PCOS Detectors WP Wall Mount Horn/Strobe WP Wall Mount Horn/Strobe Wall Mount Horn Wall Mount Strobe Wall Mount Horn/Strobe Ceiling Mount Strobe Ceiling Mount High Candela Strobe Ceiling Mount Horn/Strobe Ceiling Mount High Candela Horn/Strobe Wall Mount 520Hz Horn Wall Mount 520Hz Horn/Strobe Wall Mount Speaker/Strobe Ceiling Mount Speaker/Strobe Weatherproof Speaker/Strobe XXXX Magnetic Door Hold -Open Carbon Monoxide Detector XXXX XXXX X00( XXXX 28 92 52 92 180 90 22 85 102 127 135 245 160 285 _ 309 246 94 140 273 325 333 551 111 152 281 333 324 554 166 219 266 381 437 78 101 188 245 94 140 273 325 551 159 15 75 Z N/A END OF CIRCUIT � Re/lance Electric ect c 4795 Oakland Street, Denver, CO 80239 (720) 749-2850 element BY WEST I N 515 Industry Drive Tukwila, WA 98188 Kidde Vigilant Voltage Drop / Battery Calculations Project: Tukwila Element Panel Type: VM -1S Panel Name: FACP1 Circuit: NAC1 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 0 14 3.07 0 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 Totals: 0 0 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 0 Distance: End Line Voltage Drop: 0.00 of Voltage: 20.40 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: ' 0 0 20.40 Distance: Voltage Drop: End of Line Voltage: 0.00 End of Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 Distance: 0 End Line Voltage: Voltage Drop: 0.00 of 20.40 Project: Tukwila Element Panel Type: VM -1S Panel Name: FACP1 Circuit: NAC2 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Ouaae Ohms/ 1000' 0 14 3.07 0 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 T+140:Q42otals: 0 0 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Point to Point Method Current: 0 0 20.40 Distance: Voltage Drop: End of Line Voltage: 0.00 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Load Centering Method Current: 0 0 20.40 Distance: Voltage Drop: End of Line Voltage: 0.00 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% End Line Method Current: 0 of Distance: 0 Voltage Drop: End of Line Voltage: 20.40 0.00 Protect: Tukwila Element Panel Type: vM-1s Panel Name: FACP1 Circuit: NAC3 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guacie Ohms / 1000' 0 14 3.07 0 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 Totals: 0 0 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 Distance: 0 Voltage Drop: End of Line Voltage: 20.40 0.00 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 0 20.40 Distance: Voltage Drop: End of Line Voltage: 0.00 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 End of Line Method 0 20.40 Distance: Voltage Drop: End of Line Voltage: 0.00 Prosect: Tukwila Element Panel Type: VM -1S Panel Name: FACP1 Circuit: NAC4 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0 Distance to 1st Device: Remaining Distance: Amps System Type: 0 Wire Ohms / Guage 1000' 3.07 3.07 14 0 14 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 Totals: 0 0 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 Distance: 0 Voltage Drop: End of Line Voltage: 20.40 0.00 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 0 20.40 Distance: Voltage Drop: End of Line Voltage: 0.00 End of Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: Distance: 0 0 Voltage Drop: End of Line Voltage: 20.40 0.00 Prosect: Tukwila Element Panel Type: VM -IS Panel Name: FACP1 Battery Calculations Standy Alarm Circuit / Device Current Current Qty Total Standy Current Total Alarm Current Base Panel 381 481 VM -SLC* 120 132 VM-ETH1 42 54 VM-MFK 37 39 VM-NOC 98 98 VM -PMI 23 29 NAC Power NAC1 0 0 NAC2 0 0 NAC3 0 0 NAC4 0 0 1 3 1 1 1 1 0 0 0 0 1 1 1 1 381 360 42 37 98 23 0 0 0 0 0 0 0 0 481 396 54 39 98 29 0 0 0 0 0 0 0 0 TOTALS: 941 1097 Total Standby Current (Amps): 0.941 X 24 Hours 22.58 Amphours in Standby Total Alarm Current (Amps): 1.097 X 15 Mins: 0.27 Amphours in Alarm 22.86 Required Amphours +20% Safety Required Amphours: 22.86 Margin 27.43 Total Am hours p (2) 12V 28Ah Batteries Required. * VM -SLC is calculated at 100% capacity. (125 detectors & 125 modules per loop) DEVICE LEGEND Devices Current (Milliamps) Designator Part Number Description LightOuput 0 15cd 30cd 75cd 95cd 110cd 177cd A B C D E F G H I J K L M N O P Q R S T U V W X Y SB4U SB4U-LF GSA-SBT SIGA-AB4G-LF INT-7ATW INT-8ATW EG1F-HD EG1F-VM EG1F-HDVM EGCF-VM EGCF-VMH EGCF-HDVM EGCF-HDVMH G4LFWF-H G4LFWF-HVM G4HFWF-S7VMC GCHFWF-S7VMC INT-4ASW XXXX DHF -24120C C01224T XXXX XXXX XXXX XXXX Sounder Base for V Series Detectors 520Hz Sounder Base for V Series Detectors Sounder Base for PCOS Detectors 520Hz Sounder Base for PCOS Detectors WP Wall Mount Horn/Strobe WP Wall Mount Horn/Strobe Wall Mount Horn Wall Mount Strobe Wall Mount Horn/Strobe Ceiling Mount Strobe Ceiling Mount High Candela Strobe Ceiling Mount Horn/Strobe Ceiling Mount High Candela Horn/Strobe Wall Mount 520Hz Horn Wall Mount 520Hz Horn/Strobe Wall Mount Speaker/Strobe Ceiling Mount Speaker/Strobe Weatherproof Speaker/Strobe XXXX Magnetic Door Hold -Open Carbon Monoxide Detector XXXX XXXX XXXX XXXX 28 92 52 92 180 90 22 85 127 245 246 285 102 135 160 309 94 140 273 325 333 551 111 152 281 333 324 554 166 219 266 381 437 78 101 188 245 94 140 273 325 551 159 15 75 Z N/A END OF CIRCUIT Project: Tukwila Element Panel Type: vM-1s Panel Name: FACP2 Circuit: NAC1 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 0 14 3.07 0 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop END END END END END END END END END END END END END END END END END END END END END Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Totals: 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0.000 0 0 0 20.400 0.000 20.400 0.000 20.400 0.000 20.400 0.000 20.400 0.000 20.400 0.000 20.400 0.000 20.400 0.000 20.400 0.000 20.400 0.000 20.400 0.000 20.400 0.000 20.400 0.000 20.400 0.000 20.400 0.000 20.400 0.000 20.400 0.000 20.400 0.000 20.400 0.000 20.400 0.000 20.400 0.000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: End of Line Voltage: 0.00% Current: 0 Distance: 0 20.40 Volta 9 a Dro 0.00 p: Load Centering Method • CIRCUIT IS WITHIN LIMITS Percent Drop: End of Line Voltage: 0.00% Current: 0 Distance: 0 20.40 Voltage Drop: 0.00 End of Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: End of Line Voltage: 0.00% Current: 0 Distance:I 0 20.40 Voltage Drop: j 0.00 Project: Tukwila Element Panel Type: VM -1s Panel Name: FACP2 Circuit: NAC2 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 0 14 3.07 0 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 T+140:Q42otals: 0 0 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Point to Point Method Current: 0 0 20.40 Distance: Voltage Drop: End of Line Voltage: 0.00 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Load Centering Method Current: 0 0 20.40 Distance: Voltage Drop: End of Line Voltage: 0.00 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% End Line Method Current: 0 of Distance: 0 End Line Voltage: 20.40 Voltage Drop: 0.00 of Project: Tukwila Element Panel Type: vM-1S Panel Name: FACP2 Circuit: NAC3 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guaae Ohms/ 1000' 0 14 3.07 0 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 Totals: 0 0 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 Point to Point Method Distance: 0 End Line Voltage Drop: of Voltage: 0.00 20.40 Load Centering Method CIRCUIT IS WITHIN LIMITS 0.00% Current: Percent Drop: 0 0 End Line Voltage: 20.40 Distance: Voltage Drop: of 0.00 CIRCUIT 1S WITHIN LIMITS Current: 0 Percent Drop: 0.00% End of Line Method Distance: 0 End Line Voltage: 20.40 Voltage Drop: of 0.00 Project: Tukwila Element Panel Type: vM-1S Panel Name: FACP2 Circuit: NAC4 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guage Ohms/ 1000' 3.07 3.07 0 14 0 14 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 Totals: 0 0 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 Distance: 0 Voltage Drop: End of Line Voltage: 20.40 0.00 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 0 20.40 Distance: Voltage Drop: End of Line Voltage: 0.00 End Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 of Distance: 0 Voltage Drop: End of Line Voltage: 20.40 0.00 Prosect: Tukwila Element Panel Type: VM -1S Panel Name: FACP2 Battery Calculations Standy Alarm Circuit / Device Current Current Qty Total Standy Current Total Alarm Current Base Panel 381 481 VM -SLC* 120 132 VM-NOC 98 98 NAC Power NAC1 0 0 NAC2 0 0 NAC3 0 0 NAC4 0 0 O O O O O O CO - 381 240 98 0 0 0 0 0 0 0 0 0 0 0 481 264 98 0 0 0 0 0 0 0 0 0 0 0 TOTALS: 719 843 otal Standby Current (Amps): 0.719 X 24 Hours 17.26 Amphours in Standby Total Alarm Current (Amps): 0.843 X 15 Mins: 0.21 Amphours in Alarm 17.47 Required Amphours Required Amphours: 17.47 +20% Safety 20.96 Margin Total Amphours (2) 12V 26Ah Batteries Required. * VM -SLC is calculated at 100% capacity. (125 detectors & 125 modules per loop) DEVICE LEGEND Devices Current (Milliamps) Designator Part Number Description LightOuput 0 15cd 30cd 75cd 95cd 110cd 177cd A B C D E F G H I J K L M N 0 P Q R S T U V W X Y SB4U SB4U-LF GSA-SBT SIGA-AB4G-LF INT-7ATW INT-8ATW EG1F-HD EG1F-VM EG1F-HDVM EGCF-VM EGCF-VMH EGCF-HDVM EGCF-HDVMH G4LFWF-H G4LFWF-HVM G4HFWF-S7VMC GCHFWF-S7VMC INT-4ASW XXXX DHF-24120C C01224T XXXX XXXX XXXX XXXX Sounder Base for V Series Detectors 520Hz Sounder Base for V Series Detectors Sounder Base for PCOS Detectors 520Hz Sounder Base for PCOS Detectors WP Wall Mount Horn/Strobe WP Wall Mount Horn/Strobe Wall Mount Horn Wall Mount Strobe Wall Mount Horn/Strobe Ceiling Mount Strobe Ceiling Mount High Candela Strobe Ceiling Mount Horn/Strobe Ceiling Mount High Candela Horn/Strobe Wall Mount 520Hz Horn Wall Mount 520Hz Horn/Strobe Wall Mount Speaker/Strobe Ceiling Mount Speaker/Strobe Weatherproof Speaker/Strobe XXXX Magnetic Door Hold-Open Carbon Monoxide Detector XXXX XXXX XXXX XXXX 28 92 52 92 180 90 22 85 127 245 246 285 309 102 135 160 94 140 273 325 333 551 111 152 281 333 324 554 166 219 266 381 437 78 101 188 245 94 140 273 325 551 159 15 75 Z N/A END OF CIRCUIT Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP1 Circuit: NAC1 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.659 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaoe Ohms/ 1000' 33 14 3.07 284 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 1.1.1 Q 30 0.140 33 20.064 0.336 0.0165 1.1.2 P 15 0.078 22 19.859 0.541 0.0265 1.1.3 P 15 0.078 17 19.708 0.692 0.0339 1.1.4 P 15 0.078 11 19.616 0.784 0.0384 1.1.5 P 15 0.078 6 19.569 0.831 0.0407 1.1.6 P 15 0.078 20 19.421 0.979 0.0480 1.1.7 P 30 0.101 19 19.289 1.111 0.0545 1.1.8 Q 30 0.140 29 19.106 1.294 0.0634 1.1.9 Q 30 0.140 17 19.013 1.387 0.0680 1.1.10 Q 15 0.094 31 18.871 1.529 0.0750 1.1.11 Q 15 0.094 17 18.803 1.597 0.0783 1.1.12 Q 30 0.140 19 18.737 1.663 0.0815 1.1.13 Q 30 0.140 18 18.691 1.709 0.0838 1.1.14 Q 30 0.140 35 18.631 1.769 0.0867 1.1.15 Q 30 0.140 23 18.611 1.789 0.0877 END Z 0.000 0 18.611 1.789 0.0877 END Z 0.000 0 18.611 1.789 0.0877 END Z 0.000 0 18.611 1.789 0.0877 END Z 0.000 0 18.611 1.789 0.0877 END Z 0.000 0 18.611 1.789 0.0877 END Z 0.000 0 18.611 1.789 0.0877 Totals: 1.659 317 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 8.77% Current: 1.659 Distance: 317 End Line Voltage: Voltage Drop: 1.79 of 18.61 CIRCUIT IS WITHIN LIMITS Percent Drop: 7.91% Load Centering Method Current: 1.659 Distance: Voltage Drop: 317 End of Line Voltage: 18.79 1.61 End of Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 15.83% Current: 1.659 Distance: 317 End Line Voltage: Voltage Drop: 3.23 of 17.17 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP1 Circuit: NAC2 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.675 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaoe Ohms/ 1000' 75 14 3.07 304 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 1.2.1 P 15 0.078 75 19.629 0.771 0.0378 1.2.2 Q 30 0.140 30 19.334 1.066 0.0522 1.2.3 P 15 0.078 31 19.057 1.343 0.0658 1.2.4 Q 75 0.273 25 18.845 1.555 0.0762 1.2.5 Q 30 0.140 43 18.553 1.847 0.0905 1.2.6 Q 75 0.273 38 18.328 2.072 0.1016 1.2.7 P 15 0.078 20 18.243 2.157 0.1057 1.2.8 P 15 0.078 30 18.130 2.270 0.1113 1.2.9 J 30 0.140 13 18.087 2.313 0.1134 1.2.10 J 30 0.140 16 18.048 2.352 0.1153 1.2.11 P 15 0.078 14 18.026 2.374 0.1164 1.2.12 P 15 0.078 17 18.007 2.393 0.1173 1.2.13 P 30 0.101 27 17.990 2.410 0.1181 END Z 0.000 0 17.990 2.410 0.1181 END Z 0.000 0 17.990 2.410 0.1181 END Z 0.000 0 17.990 2.410 0.1181 END Z 0.000 0 17.990 2.410 0.1181 END Z 0.000 0 17.990 2.410 0.1181 END Z 0.000 0 17.990 2.410 0.1181 END Z 0.000 0 17.990 2.410 0.1181 END Z 0.000 0 17.990 2.410 0.1181 T+I40:Q42otals: 1.675 379 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 11.81% Current: 1.675 Distance: 379 Voltage Drop: End of Line Voltage: 17.99 2.41 CIRCUIT IS WITHIN LIMITS Percent Drop: 9.55% Load Centering Method Current: 1.675 379 18.45 Distance: Voltage Drop: End of Line Voltage: 1.95 CIRCUIT IS WITHIN LIMITS Percent Drop: 19.11% Current: 1.675 End of Line Method 379 16.50 Distance: Voltage Drop: End of Line Voltage: 3.90 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP1 Circuit: NAC3 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.773 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guaae Ohms/ 1000' 11 14 3.07 265 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 1.3.1 P 30 0.101 11 20.280 0.120 0.0059 1.3.2 Q 30 0.140 38 19.890 0.510 0.0250 1.3.3 H 15 0.085 28 19.627 0.773 0.0379 1.3.4 P 30 0.101 12 19.520 0.880 0.0431 1.3.5 Q 75 0.273 28 19.289 1.111 0.0545 1.3.6 Q 75 0.273 14 19.197 1.203 0.0590 1.3.7 P 15 0.078 30 19.049 1.351 0.0662 1.3.8 P 15 0.078 11 19.000 1.400 0.0686 1.3.9 H 15 0.085 22 18.913 1.487 0.0729 1.3.10 R 75 0.159 7 18.889 1.511 0.0741 1.3.11 R 75 0.159 41 18.789 1.611 0.0790 1.3.12 Q 30 0.140 23 18.755 1.645 0.0807 1.3.13 P 30 0.101 11 18.748 1.652 0.0810 END Z 0.000 0 18.748 1.652 0.0810 END Z 0.000 0 18.748 1.652 0.0810 END Z 0.000 0 18.748 1.652 0.0810 END Z 0.000 0 18.748 1.652 0.0810 END Z 0.000 0 18.748 1.652 0.0810 END Z 0.000 0 18.748 1.652 0.0810 END Z 0.000 0 18.748 1.652 0.0810 END Z 0.000 0 18.748 1.652 0.0810 Totals: 1.773 276 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 8.10% Current: 1.773 Distance: 276 End Line Voltage: 18.75 Voltage Drop: 1.65 of CIRCUIT IS WITHIN LIMITS Percent Drop: 7.36% Load Centering Method Current: 1.773 276 18.90 Distance: Voltage Drop: End of Line Voltage: 1.50 End of Line Method CIRCUIT IS WITHIN LIMITSI Percent Drop: 14.73% Current: 1.773 Distance: 276 End Line Voltage: 17.40 Voltage Drop: 3.00 of Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP1 Circuit: NAC4 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guaae Ohms/ 1000' 0 14 3.07 0 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 Totals: 0 0 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 Point to Point Method 0 20.40 Distance: End of Line Voltage: 0.00 Voltage Drop: CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 Load Centering Method 0 20.40 Distance: End of Line Voltage: 0.00 Voltage Drop: CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 End of Line Method 0 20.40 Distance: Voltage Drop: End of Line Voltage: 0.00 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP1 Battery Calculations Standy Circuit / Device Current Alarm Current Qty Total Standy Current Total Alarm Current Power Supply 70 70 1 70 70 NAC Power NAC1 0 1659 1 0 1659 NAC2 0 1675 1 0 1675 NAC3 0 1773 1 0 1773 NAC4 0 0 0 0 0 200 mA Aux Power Aux 0 0 0 0 0 Aux 0 0 0 0 0 Aux 0 0 0 0 0 TOTALS: 70 5177 Total Standy Current (Amps): 0.07 X 24 Hours: 1.68 Amphours in Standy Total Alarm Current (Amps): 5.177 X 15 Mins: 1.29 Amphours in Alarm 2.97 Required Amphours Required Amphours: +20% Safety 2.97 3'57 Total Margin Am hours p (2) 12V 8Ah Batteries Required. "Magnetic Door Holders are not included in the battery calculations. Power to these devices will be automatically disconnected upon Toss of NC power to reduce battery size. DEVICE LEGEND Devices Current (Milliamps) Designator Part Number Description Light Ouput 0 15cd 30cd 75cd 95cd 110cd 177cd A B C D E F G H I J K L M N O P Q R S T U V W X Y SB4U SB4U-LF GSA-SBT SIGA-AB4G-LF INT-7ATW INT-8ATW EG1F-HD EG1F-VM EG1F-HDVM EGCF-VM EGCF-VMH EGCF-HDVM EGCF-HDVMH G4LFWF-H G4LFWF-HVM G4HFWF-S7VMC GCHFWF-S7VMC INT-4ASW XXXX DHF -24120C C01224T XXXX XXXX XXXX XXXX Sounder Base for V Series Detectors 520Hz Sounder Base for V Series Detectors) Sounder Base for PCOS Detectors 520Hz Sounder Base for PCOS Detectors WP Wall Mount Horn/Strobe WP Wall Mount Horn/Strobe Wall Mount Horn Wall Mount Strobe Wall Mount Horn/Strobe Ceiling Mount Strobe Ceiling Mount High Candela Strobe Ceiling Mount Horn/Strobe Ceiling Mount High Candela Horn/Strobe Wall Mount 520Hz Horn Wall Mount 520Hz Horn/Strobe Wall Mount Speaker/Strobe Ceiling Mount Speaker/Strobe Weatherproof Speaker/Strobe XXXX Magnetic Door Hold -Open Carbon Monoxide Detector XX CX XXXX XXXX XXXX 28 92 52 92 180 90 22 85 127 245 246 285 309 102 135 160 94 140 273 325 333 551 111 152 281 333 324 554 166 219 266 381 437 78 101 188 245 94 140 273 325 551 159 15 75 Z N/A END OF CIRCUIT Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP2 Circuit: NAC1 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0.82 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 140 14 3.07 65 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 2.1.1 P 110 0.245 140 19.695 0.705 0.0346 2.1.2 P 110 0.245 19 19.628 0.772 0.0378 2.1.3 H 15 0.085 10 19.608 0.792 0.0388 2.1.4 P 110 0.245 36 19.554 0.846 0.0415 END Z 0.000 0 19.554 0.846 0.0415 END Z 0.000 0 19.554 0.846 0.0415 END Z 0.000 0 19.554 0.846 0.0415 END Z 0.000 0 19.554 0.846 0.0415 END Z 0.000 0 19.554 0.846 0.0415 END Z 0.000 0 19.554 0.846 0.0415 END Z 0.000 0 19.554 0.846 0.0415 END Z 0.000 0 19.554 0.846 0.0415 END Z 0.000 0 19.554 0.846 0.0415 END Z 0.000 0 19.554 0.846 0.0415 END Z 0.000 0 19.554 0.846 0.0415 END Z 0.000 0 19.554 0.846 0.0415 END Z 0.000 0 19.554 0.846 0.0415 END Z 0.000 0 19.554 0.846 0.0415 END Z 0.000 0 19.554 0.846 0.0415 END Z 0.000 0 19.554 0.846 0.0415 END Z 0.000 0 19.554 0.846 0.0415 Totals: 0.82 205 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 4.15% Current: 0.82 Distance: 205 End Line Voltage Drop: 0.85 of Voltage: 19.55 CIRCUIT IS WITHIN LIMITS Percent Drop: 2.53% Load Centering Method Current: 0.82 205 19.88 Distance: Voltage Drop: End of Line Voltage: 1 0.52 CIRCUIT IS WITHIN LIMITS Percent Drop: 5.06% End of Line Method Current: 0.82 205 19.37 Distance: Voltage Drop: End of Line Voltage: 1.03 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP2 Circuit: NAC2 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaoe Ohms/ 1000' 0 14 3.07 0 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 T+140:Q42otals: 0 0 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 Point to Point Method 0 20.40 Distance: Voltage Drop: End of Line Voltage: 0.00 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Load Centering Method Current: 0 0 20.40 Distance: Voltage Drop: End of Line Voltage: 0.00 End Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 of Distance: 0 Voltage Drop: End of Line Voltage: 20.40 0.00 Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP2 Circuit: NAC3 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.555 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guaae Ohms/ 1000' 11 14 3.07 129 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 2.3.1 P 110 0.245 11 20.295 0.105 0.0051 2.3.2 P 110 0.245 9 20.223 0.177 0.0087 2.3.3 P 110 0.245 34 20.000 0.400 0.0196 2.3.4 P 110 0.245 23 19.884 0.516 0.0253 2.3.5 P 110 0.245 25 19.796 0.604 0.0296 2.3.6 P 110 0.245 24 19.748 0.652 0.0320 2.3.7 H 15 0.085 14 19.740 0.660 0.0323 END Z 0.000 0 19.740 0.660 0.0323 END Z 0.000 0 19.740 0.660 0.0323 END Z 0.000 0 19.740 0.660 0.0323 END Z 0.000 0 19.740 0.660 0.0323 END Z 0.000 0 19.740 0.660 0.0323 END Z 0.000 0 19.740 0.660 0.0323 END Z 0.000 0 19.740 0.660 0.0323 END Z 0.000 0 19.740 0.660 0.0323 END Z 0.000 0 19.740 0.660 0.0323 END Z 0.000 0 19.740 0.660 0.0323 END Z 0.000 0 19.740 0.660 0.0323 END Z 0.000 0 19.740 0.660 0.0323 END Z 0.000 0 19.740 0.660 0.0323 END Z 0.000 0 19.740 0.660 0.0323 Totals: 1.555 140 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 3.23% Current: 1.555 Distance: 140 End Line Voltage: Voltage Drop: 0.66 of 19.74 CIRCUIT IS WITHIN LIMITS Percent Drop: 3.28% Load Centering Method Current: 1.555 Distance: Voltage Drop: 140 End of Line Voltage: 19.73 0.67 End of Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 6.55% Current: 1.555 Distance: 140 End Line Voltage: Voltage Drop: 1.34 of 19.06 Proiect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP2 Circuit: NAC4 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0.828 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guacie Ohms/ 1000' 7 14 3.07 195 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 2.4.1 D 0.092 7 20.364 0.036 0.0017 2.4.2 D 0.092 20 20.274 0.126 0.0062 2.4.3 D 0.092 15 20.215 0.185 0.0091 2.4.4 D 0.092 30 20.113 0.287 0.0141 2.4.5 D 0.092 17 20.065 0.335 0.0164 2.4.6 D 0.092 26 20.006 0.394 0.0193 2.4.7 D 0.092 32 19.952 0.448 0.0220 2.4.8 D 0.092 27 19.922 0.478 0.0235 2.4.9 D 0.092 28 19.906 0.494 0.0242 END Z 0.000 0 19.906 0.494 0.0242 END Z 0.000 0 19.906 0.494 0.0242 END Z 0.000 0 19.906 0.494 0.0242 END Z 0.000 0 19.906 0.494 0.0242 END Z 0.000 0 19.906 0.494 0.0242 END Z 0.000 0 19.906 0.494 0.0242 END Z 0.000 0 19.906 0.494 0.0242 END Z 0.000 0 19.906 0.494 0.0242 END Z 0.000 0 19.906 0.494 0.0242 END Z 0.000 0 19.906 0.494 0.0242 END Z 0.000 0 19.906 0.494 0.0242 END Z 0.000 0 19.906 0.494 0.0242 Totals: 0.828 202 CIRCUIT IS WITHIN LIMITS Percent Drop: 2.42% Current: 0.828 Point to Point Method 202 19.91 Distance: Voltage Drop: End of Line Voltage: 0.49 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 2.52% Current: 0.828 202 19.89 Distance: Voltage Drop: End of Line Voltage: 0.51 CIRCUIT IS WITHIN LIMITS Percent Drop: 5.03% Current: 0.828 End of Line Method 202 19.37 Distance: Voltage Drop: End of Line Voltage: 1.03 Prosect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP2 Battery Calculations Standy Circuit / Device Current Alarm Current Qty Total Standy Current Total Alarm Current Power Supply 70 70 1 70 70 NAC Power NAC1 0 820 1 0 820 NAC2 0 0 0 0 0 NAC3 0 1555 1 0 1555 NAC4 54 828 1 54 0 200 mA Aux Power Aux 0 0 0 0 0 Aux 0 0 0 0 0 Aux 0 0 0 0 0 TOTALS: 124 2445 Total Standy Current (Amps): 0.124 X 24 Hours: 2.976 Amphours in Standy Total Alarm Current (Amps): 2.445 X 15 Mins: 0.61 Amphours in Alarm 3.59 Required Amphours Required Amphours: +20% Safety 3.59 4.30 Total Margin Am hours P (2) 12V 8Ah Batteries Required. *Magnetic Door Holders are not included in the battery calculations. Power to these devices will be automatically disconnected upon Toss of A/C power to reduce battery size. DEVICE LEGEND Devices Current (Milliamps) Designator Part Number Description LightOuput 0 15cd 30cd 75cd 95cd 110cd 177cd A B C D E F G H I J K L M N 0 P Q R S T U V W X Y SB4U SB4U-LF GSA-SBT SIGA-AB4G-LF INT-7ATW INT-8ATW EG1 F-HD EG1F-VM EG1F-HDVM EGCF-VM EGCF-VMH EGCF-HDVM EGCF-HDVMH G4LFWF-H G4LFWF-HVM G4HFWF-S7VMC GCHFWF-S7VMC INT-4ASW XXXX DHF-24120C C01224T XXXX XXXX XXXX XXXX Sounder Base for V Series Detectors 520Hz Sounder Base for V Series Detectors Sounder Base for PCOS Detectors 520Hz Sounder Base for PCOS Detectors WP Wall Mount Horn/Strobe WP Wall Mount Horn/Strobe Wall Mount Horn Wall Mount Strobe Wall Mount Horn/Strobe Ceiling Mount Strobe Ceiling Mount High Candela Strobe Ceiling Mount Horn/Strobe Ceiling Mount High Candela Horn/Strobe Wall Mount 520Hz Horn Wall Mount 520Hz Horn/Strobe Wall Mount Speaker/Strobe Ceiling Mount Speaker/Strobe Weatherproof Speaker/Strobe XXXX Magnetic Door Hold-Open Carbon Monoxide Detector )(XXX XXXX XXXX XXXX 28 92 52 92 180 90 22 85 127 245 285 102 135 160 246 309 94 140 273 325 333 551 111 152 281 333 324 554 166 219 266 381 437 78 101 188 245 94 140 273 325 551 159 15 75 Z N/A END OF CIRCUIT Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP3 Circuit: NAC1 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.065 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guacie Ohms/ 1000' 33 14 3.07 69 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 3.1.1 P 110 0.245 33 20.184 0.216 0.0106 3.1.2 P 110 0.245 23 20.068 0.332 0.0163 3.1.3 P 110 0.245 9 20.037 0.363 0.0178 3.1.4 H 15 0.085 8 20.020 0.380 0.0186 3.1.5 P 110 0.245 29 19.977 0.423 0.0207 END Z 0.000 0 19.977 0.423 0.0207 END Z 0.000 0 19.977 0.423 0.0207 END Z 0.000 0 19.977 0.423 0.0207 END Z 0.000 0 19.977 0.423 0.0207 END Z 0.000 0 19.977 0.423 0.0207 END Z 0.000 0 19.977 0.423 0.0207 END Z 0.000 0 19.977 0.423 0.0207 END Z 0.000 0 19.977 0.423 0.0207 END Z 0.000 0 19.977 0.423 0.0207 END Z 0.000 0 19.977 0.423 0.0207 END Z 0.000 0 19.977 0.423 0.0207 END Z 0.000 0 19.977 0.423 0.0207 END Z 0.000 0 19.977 0.423 0.0207 END Z 0.000 0 19.977 0.423 0.0207 END Z 0.000 0 19.977 0.423 0.0207 END Z 0.000 0 19.977 0.423 0.0207 Totals: 1.065 102 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 2.07% Current: 1.065 Distance: 102 End Line Voltage: 19.98 Voltage Drop: 0.42 of Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 1.63% Current: 1.065 Distance: 102 End Line Voltage Drop: i 0.33 of Voltage: 20.07 End Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 3.27% Current: 1.065 of Distance: 102 End Voltage Drop: 0.67 of Line Voltage: 19.73 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP3 Circuit: NAC2 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.47 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms / 1000' 80 14 3.07 103 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 3.2.1 P 110 0.245 80 19.678 0.722 0.0354 3.2.2 P 110 0.245 21 19.520 0.880 0.0431 3.2.3 P 110 0.245 22 19.388 1.012 0.0496 3.2.4 P 110 0.245 20 19.297 1.103 0.0541 3.2.5 P 110 0.245 19 19.240 1.160 0.0569 3.2.6 P 110 0.245 21 19.209 1.191 0.0584 END Z 0.000 0 19.209 1.191 0.0584 END Z 0.000 0 19.209 1.191 0.0584 END Z 0.000 0 19.209 1.191 0.0584 END Z 0.000 0 19.209 1.191 0.0584 END Z 0.000 0 19.209 1.191 0.0584 END Z 0.000 0 19.209 1.191 0.0584 END Z 0.000 0 19.209 1.191 0.0584 END Z 0.000 0 19.209 1.191 0.0584 END Z 0.000 0 19.209 1.191 0.0584 END Z 0.000 0 19.209 1.191 0.0584 END Z 0.000 0 19.209 1.191 0.0584 END Z 0.000 0 19.209 1.191 0.0584 END Z 0.000 0 1 19.209 1.191 0.0584 END Z 0.000 0 19.209 1.191 0.0584 END Z 0.000 0 19.209 1.191 0.0584 T+140:Q42otals: 1.47 183 CIRCUIT IS WITHIN LIMITS Percent Drop: 5.84% Point to Point Method Current: 1.47 183 19.21 Distance: Voltage Drop: End of Line Voltage: 1.19 CIRCUIT IS WITHIN LIMITS Percent Drop: 4.05% Load Centering Method Current: 1.47 183 19.57 Distance: Voltage Drop: End of Line Voltage: 0.83 CIRCUIT IS WITHIN LIMITS Percent Drop: 8.10% End of Line Method Current: 1.47 183 18.75 Distance: Voltage Drop: End of Line Voltage: 1.65 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP3 Circuit: NAC3 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0.413 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guaae Ohms / 1000' 9 14 3.07 138 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 3.3.1 P 30 0.101 9 20.377 0.023 - 0.0011 3.3.2 P 15 0.078 3 20.371 0.029 0.0014 3.3.3 P 15 0.078 52 20.297 0.103 0.0051 3.3.4 P 15 0.078 52 20.247 0.153 0.0075 3.3.5 P 15 0.078 31 20.232 0.168 0.0082 END Z 0.000 0 20.232 0.168 0.0082 END Z 0.000 0 20.232 0.168 0.0082 END Z 0.000 0 20.232 0.168 0.0082 END Z 0.000 0 20.232 0.168 0.0082 END Z 0.000 0 20.232 0.168 0.0082 END Z 0.000 0 20.232 0.168 0.0082 END Z 0.000 0 20.232 0.168 0.0082 END Z 0.000 0 20.232 0.168 0.0082 END Z 0.000 0 20.232 0.168 0.0082 END Z 0.000 0 20.232 0.168 0.0082 END Z 0.000 0 20.232 0.168 0.0082 END Z 0.000 0 20.232 0.168 0.0082 END Z 0.000 0 20.232 0.168 0.0082 END Z 0.000 0 20.232 0.168 0.0082 END Z 0.000 0 20.232 0.168 0.0082 END Z 0.000 0 20.232 0.168 0.0082 Totals: 0.413 147 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 0.82% Current: 0.413 Distance: 147 End Line Voltage: Voltage Drop: 0.17 of 20.23 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.91% Load Centering Method Current: 0.413 Distance: Voltage Drop: 147 i End of Line Voltage: 20.21 0.19 CIRCUIT IS WITHIN LIMITS Percent Drop: 1.83% End of Line Method Current: 0.413 147 20.03 Distance: Voltage Drop: End of Line Voltage: 0.37 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP3 Circuit: NAC4 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0.92 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guage Ohms/ 1000' 37 14 3.07 186 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 3.4.1 • D 0.092 37 20.191 0.209 0.0102 3.4.2 D 0.092 22 20.079 0.321 0.0157 3.4.3 D 0.092 21 19.984 0.416 0.0204 3.4.4 D 0.092 18 19.913 0.487 0.0239 3.4.5 D 0.092 20 19.845 0.555 0.0272 3.4.6 D 0.092 25 19.775 0.625 0.0307 3.4.7 D 0.092 21 19.727 0.673 0.0330 3.4.8 D 0.092 19 19.695 0.705 0.0346 3.4.9 D 0.092 19 19.674 0.726 0.0356 3.4.10 D 0.092 21 19.662 0.738 0.0362 END Z 0.000 0 19.662 0.738 0.0362 END Z 0.000 0 19.662 0.738 0.0362 END Z 0.000 0 19.662 0.738 0.0362 END Z 0.000 0 19.662 0.738 0.0362 END Z 0.000 0 19.662 0.738 0.0362 END Z 0.000 0 19.662 0.738 0.0362 END Z 0.000 0 19.662 0.738 0.0362 END Z 0.000 0 19.662 0.738 0.0362 END Z 0.000 0 19.662 0.738 0.0362 END Z 0.000 0 19.662 0.738 0.0362 END Z 0.000 0 19.662 0.738 0.0362 Totals: 0.92 223 Method CIRCUIT IS WITHIN LIMITS Percent Drop: 3.62% Current: 0.92 Point to Point Distance: 223 Voltage Drop: End of Line Voltage: 19.66 0.74 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 3.09% Current: 0.92 Distance: 223 Voltage Drop: End of Line Voltage: 19.77 0.63 End Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 6.17% Current: 0.92 of Distance: 223 Voltage Drop: End of Line Voltage: 19.14 1.26 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP3 Battery Calculations Standy Circuit / Device Current Alarm Current Qty Total Standy Current Total Alarm Current Power Supply 70 70 1 70 70 NAC Power NAC1 0 1065 1 0 1065 NAC2 0 1470 1 0 1470 NAC3 0 413 1 0 413 NAC4 60 920 1 60 0 200 mA Aux Power Aux 0 0 0 0 0 Aux 0 0 0 0 0 Aux 0 0 0 0 0 TOTALS: 130 3018 Total Standy Current (Amps): 0.13 X 24 Hours: 3.12 Amphours in Standy Total Alarm Current (Amps): 3.018 X 15 Mins: 0.75 Amphours in Alarm 3.87 Required Amphours Required Amphours: +20% Safety 3.87 4.65 Total Margin Am hours p (2) 12V 8Ah Batteries Required. *Magnetic Door Holders are not included in the battery calculations. Power to these devices will be automatically disconnected upon loss of NC power to reduce battery size. DEVICE LEGEND Devices Current (Milliamps) Designator Part Number Description Light Ouput 0 15cd 30cd 75cd 95cd 110cd 177cd A B C D E F G H I J K L M N 0 P Q R S T U V W X Y SB4U SB4U-LF GSA-SBT SIGA-AB4G-LF INT-7ATW INT-8ATW EG1 F -HD EG1F-VM EG1F-HDVM EGCF-VM EGCF-VMH EGCF-HDVM EGCF-HDVMH G4LFWF-H G4LFWF-HVM G4HFWF-S7VMC GCHFWF-S7VMC INT-4ASW XXXX DHF -24120C C01224T XXXX XXXX XXXX XXXX Sounder Base for V Series Detectors 520Hz Sounder Base for V Series Detectors Sounder Base for PCOS Detectors 520Hz Sounder Base for PCOS Detectors WP Wall Mount Horn/Strobe WP Wall Mount Horn/Strobe Wall Mount Horn Wall Mount Strobe Wall Mount Horn/Strobe Ceiling Mount Strobe Ceiling Mount High Candela Strobe Ceiling Mount Horn/Strobe Ceiling Mount High Candela Horn/Strobe Wall Mount 520Hz Horn Wall Mount 520Hz Horn/Strobe Wall Mount Speaker/Strobe Ceiling Mount Speaker/Strobe Weatherproof Speaker/Strobe XXXX Magnetic Door Hold -Open Carbon Monoxide Detector XXXX XXXX XXXX XXXX 28 92 52 92 180 90 22 8.5 102 127 245 285 309 135 160 246 94 140 273 325 333 551 111 152 281 333 324 554 166 219 266 381 437 78 101 188 245 94 140 273 325 551 159 15 75 Z N/A END OF CIRCUIT Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP4 Circuit: NAC1 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.225 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 152 14 3.07 78 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 4.1.1 P 110 0.245 152 19.257 1.143 0.0560 4.1.2 P 110 0.245 20 19.136 1.264 0.0619 4.1.3 P 110 0.245 10 19.091 1.309 0.0642 4.1.4 P 110 0.245 42 18.965 1.435 0.0703 4.1.5 P 110 0.245 6 18.956 1.444 0.0708 END Z 0.000 0 18.956 1.444 0.0708 END Z 0.000 0 18.956 1.444 0.0708 END Z 0.000 0 18.956 1.444 0.0708 END Z 0.000 0 18.956 1.444 0.0708 END Z 0.000 0 18.956 1.444 0.0708 END Z 0.000 0 18.956 1.444 0.0708 END Z 0.000 0 18.956 1.444 0.0708 END Z 0.000 0 18.956 1.444 0.0708 END Z 0.000 0 18.956 1.444 0.0708 END Z 0.000 0 18.956 1.444 0.0708 END Z 0.000 0 18.956 1.444 0.0708 END Z 0.000 0 18.956 1.444 0.0708 END Z 0.000 0 18.956 1.444 0.0708 END Z 0.000 0 18.956 1.444 0.0708 END Z 0.000 0 18.956 1.444 0.0708 END Z 0.000 0 18.956 1.444 0.0708 Totals: 1.225 230 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 7.08% Current: 1.225 Distance: i 230 End Line Voltage: Voltage Drop: 1.44 of 18.96 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 4.24% Current: 1.225 230 19.54 Distance: Voltage Drop: End of Line Voltage: j 0.86 End of Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 8.48% Current: 1.225 230 18.67 Distance: Voltage Drop: End of Line Voltage: 1 1.73 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP4 Circuit: NAC2 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.555 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaoe Ohms/ 1000' 103 14 3.07 128 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 4.2.1 P 110 0.245 103 19.417 0.983 0.0482 4.2.2 P 110 0.245 26 19.207 1.193 0.0585 4.2.3 P 110 0.245 17 19.096 1.304 0.0639 4.2.4 P 110 0.245 37 18.910 1.490 0.0730 4.2.5 P 110 0.245 17 18.850 1.550 0.0760 4.2.6 H 15 0.085 8 18.834 1.566 0.0768 4.2.7 P 110 0.245 23 18.799 1.601 0.0785 END Z 0.000 0 18.799 1.601 0.0785 END Z 0.000 0 18.799 1.601 0.0785 END Z 0.000 0 18.799 1.601 0.0785 END Z 0.000 0 18.799 1.601 0.0785 END Z 0.000 0 18.799 1.601 0.0785 END Z 0.000 0 18.799 1.601 0.0785 END Z 0.000 0 18.799 1.601 0.0785 END Z 0.000 0 18.799 1.601 0.0785 END Z 0.000 0 18.799 1.601 0.0785 END Z 0.000 0 18.799 1.601 0.0785 END Z 0.000 0 18.799 1.601 0.0785 END Z 0.000 0 18.799 1.601 0.0785 END Z 0.000 0 18.799 1.601 0.0785 END Z 0,000 0 18.799 1.601 0.0785 T+I40:Q42otals: 1.555 231 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 7.85% Current: 1.555 Distance: 231 Voltage Drop: End of Line Voltage: 18.80 1.60 CIRCUIT IS WITHIN LIMITS Percent Drop: 5.41% Load Centering Method Current: 1.555 231 19.30 Distance: Voltage Drop: End of Line Voltage: 1.10 CIRCUIT IS WITHIN LIMITS Percent Drop: 10.81% End of Line Method Current: 1.555 231 18.19 Distance: Voltage Drop: End of Line Voltage: 2.21 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP4 Circuit: NAC3 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.225 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guaae Ohms/ 1000' 15 14 3.07 94 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 4.3.1 P 110 0.245 15 20.287 0.113 0.0055 4.3.2 P 110 0.245 23 20.149 0.251 0.0123 4.3.3 P 110 0.245 33 20.000 0.400 0.0196 4.3.4 P 110 0.245 9 19.973 0.427 0.0209 4.3.5 P 110 0.245 29 19.929 0.471 0.0231 END Z 0.000 0 19.929 0.471 0.0231 END Z 0.000 0 19.929 0.471 0.0231 END Z 0.000 0 19.929 0.471 0.0231 END Z 0.000 0 19.929 0.471 0.0231 END Z 0.000 0 19.929 0.471 0.0231 END Z 0.000 0 19.929 0.471 0.0231 END Z 0.000 0 19.929 0.471 0.0231 END Z 0.000 0 19.929 0.471 0.0231 END Z 0.000 0 19.929 0.471 0.0231 END Z 0.000 0 19.929 0.471 0.0231 END Z 0.000 0 19.929 0.471 0.0231 END Z 0.000 0 19.929 0.471 0.0231 END Z 0.000 0 19.929 0.471 0.0231 END Z 0.000 0 19.929 0.471 0.0231 END Z 0.000 0 19.929 0.471 0.0231 END Z 0.000 0 19.929 0.471 0.0231 Totals: 1.225 109 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 2.31% Current: 1.225 Distance: 109 End Voltage Drop: 0.47 of Line Voltage: 19.93 CIRCUIT IS WITHIN LIMITS Percent Drop: 2.01% Load Centering Method Current: 1.225 109 19.99 Distance: Voltage Drop: End of Line Voltage: 0.41 End of Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 4.02% Current: 1.225 Distance: 109 End Line Voltage: Voltage Drop: 0.82 of 19.58 Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP4 Circuit: NAC4 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.012 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guage Ohms/ 1000' 17 14 3.07 239 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 4.4.1 D 0.092 17 20.294 0.106 0.0052 4.4.2 D 0.092 25 20.153 0.247 0.0121 4.4.3 D 0.092 23 20.036 0.364 0.0178 4.4.4 D 0.092 22 19.937 0.463 0.0227 4.4.5 D 0.092 22 19.850 0.550 0.0270 4.4.6 D 0.092 26 19.762 0.638 0.0313 4.4.7 D 0.092 17 19.714 0.686 0.0336 4.4.8 D 0.092 24 19.659 0.741 0.0363 4.4.9 D 0.092 27 19.614 0.786 0.0385 4.4.10 D 0.092 28 19.582 0.818 0.0401 4.4.11 D 0.092 25 19.568 0.832 0.0408 END Z 0.000 0 19.568 0.832 0.0408 END Z 0.000 0 19.568 0.832 0.0408 END Z 0.000 0 19.568 0.832 0.0408 END Z 0.000 0 19.568 0.832 0.0408 END Z 0.000 0 19.568 0.832 0.0408 END Z 0.000 0 19.568 0.832 0.0408 END Z 0.000 0 19.568 0.832 0.0408 END Z 0.000 0 19.568 0.832 0.0408 END Z 0.000 0 19.568 0.832 0.0408 END Z 0.000 0 19.568 0.832 0.0408 Totals: 1.012 256 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 4.08% Current: 1.012 Distance: 256 Voltage Drop: End of Line Voltage: 19.57 0.83 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 3.90% Current: 1.012 256 19.60 Distance: Voltage Drop: End of Line Voltage: 0.80 End Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 7.80% Current: 1.012 of Distance: 256 Voltage Drop: End of Line Voltage: 18.81 1.59 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP4 Battery Calculations Standy Circuit / Device Current Alarm Current Qty Total Standy Current Total Alarm Current Power Supply 70 70 1 70 70 NAC Power NAC1 0 1225 1 0 1225 NAC2 0 1555 1 0 1555 NAC3 0 1225 1 0 1225 NAC4 66 1012 1 66 0 200 mA Aux Power Aux 0 0 0 0 0 Aux 0 0 0 0 0 Aux 0 0 0 0 0 TOTALS: 136 4075 Total Standy Current (Amps): 0.136 X 24 Hours: 3.264 Amphours in Standy Total Alarm Current (Amps): 4.075 X 15 Mins: 1.02 Amphours in Alarm 4.28 Required Amphours Required Amphours: +20% Safety 4.28 5.14 Total Margin Am hours p (2) 12V 8Ah Batteries Required. *Magnetic Door Holders are not included in the battery calculations. Power to these devices will be automatically disconnected upon loss of A/C power to reduce battery size. DEVICE LEGEND Devices Current (Milliamps) Designator Part Number Description Light Ouput 0 15cd 30cd 75cd 95cd 110cd 177cd A B C D E F G H I J K L M N 0 P Q R S T U V W X Y SB4U SB4U-LF GSA-SBT SIGA-AB4G-LF INT-7ATW INT-8ATW EG1F-HD EG1F-VM EG1F-HDVM EGCF-VM EGCF-VMH EGCF-HDVM EGCF-HDVMH G4LFWF-H G4LFWF-HVM G4HFWF-S7VMC GCHFWF-S7VMC INT-4ASW XXXX DHF -24120C CO1224T XXXX XXXX XXXX XXXX Sounder Base for V Series Detectors 520Hz Sounder Base for V Series Detectors Sounder Base for PCOS Detectors 520Hz Sounder Base for PCOS Detectors WP Wall Mount Horn/Strobe WP Wall Mount Horn/Strobe Wall Mount Horn Wall Mount Strobe Wall Mount Horn/Strobe Ceiling Mount Strobe Ceiling Mount High Candela Strobe Ceiling Mount Horn/Strobe Ceiling Mount High Candela Horn/Strobe Wall Mount 520Hz Horn Wall Mount 520Hz Horn/Strobe Wall Mount Speaker/Strobe Ceiling Mount Speaker/Strobe Weatherproof Speaker/Strobe XXXX Magnetic Door Hold -Open Carbon Monoxide Detector XXXX XXXX XXXX XXXX 28 92 52 92 180 90 22 85 127 245 285 102 135 160 246 309 94 140 273 325 333 551 111 152 281 333 324 554 166 219 266 381 437 78 101 188 245 94 140 273 325 551 159 15 75 Z N/A END OF CIRCUIT Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP5 Circuit: NAC1 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.47 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 38 14 3.07 98 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 5.1.1 P 110 0.245 38 20.057 0.343 0.0168 5.1.2 P 110 0.245 17 19.929 0.471 0.0231 5.1.3 P 110 0.245 24 19.785 0.615 0.0302 5.1.4 P 110 0.245 16 19.713 0.687 0.0337 5.1.5 P 110 0.245 24 19.640 0.760 0.0372 5.1.6 P 110 0.245 17 19.615 0.785 0.0385 END Z 0.000 0 19.615 0.785 0.0385 END Z 0.000 0 19.615 0.785 0.0385 END Z 0.000 0 19.615 0.785 0.0385 END Z 0.000 0 19.615 0.785 0.0385 END Z 0.000 0 19.615 0.785 0.0385 END Z 0.000 0 19.615 0.785 0.0385 END Z 0.000 0 19.615 0.785 0.0385 END Z 0.000 0 19.615 0.785 0.0385 END Z 0.000 0 19.615 0.785 0.0385 END Z 0.000 0 19.615 0.785 0.0385 END Z 0.000 0 19.615 0.785 0.0385 END Z 0.000 0 19.615 0.785 0.0385 END Z 0.000 0 19.615 0.785 0.0385 END Z 0.000 0 19.615 0.785 0.0385 END Z 0.000 0 19.615 0.785 0.0385 Totals: 1.47 136 CIRCUIT IS WITHIN LIMITS Percent Drop: 3.85% Current: 1.47Distance: Point to Point Method 136 End of Line Voltage: 19.61 Voltage Drop: 0.79 CIRCUIT IS WITHIN LIMITS Load Centering Method Current:' 1.47 Percent Drop: 3.01 % Distance: 136 19.79 End of Line Voltage: Voltage Drop: 0.61 CIRCUIT IS WITHIN LIMITS Percent Drop: 6.02% Current: 1.47 End of Line Method End Line Voltage: Distance: 136 Voltage Drop:; 1.23 of 19.17 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP5 Circuit: NAC2 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.47 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 185 14 3.07 76 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 5.2.1 P 110 0.245 185 18.730 1.670 0.0819 5.2.2 P 110 0.245 22 18.565 1.835 0.0900 5.2.3 P 110 0.245 9 18.511 1.889 0.0926 5.2.4 P 110 0.245 29 18.380 2.020 0.0990 5.2.5 P 110 0.245 7 18.359 2.041 0.1001 5.2.6 P 110 0.245 9 18.345 2.055 0.1007 END Z 0.000 0 18.345 2.055 0.1007 END Z 0.000 0 18.345 2.055 0.1007 END Z 0.000 0 18.345 2.055 0.1007 END Z 0.000 0 18.345 2.055 0.1007 END Z 0.000 0 18.345 2.055 0.1007 END Z 0.000 0 18.345 2.055 0.1007 END Z 0.000 0 18.345 2.055 0.1007 END Z 0.000 0 18.345 2.055 0.1007 END Z 0.000 0 18.345 2.055 0.1007 END Z 0.000 0 18.345 2.055 0.1007 END Z 0.000 0 18.345 2.055 0.1007 END Z 0.000 0 18.345 2.055 0.1007 END Z 0.000 0 18.345 2.055 0.1007 END Z 0.000 0 18.345 2.055 0.1007 END Z 0.000 0 18.345 2.055 0.1007 T+I40:Q42otals: 1.47 261 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 10.07% Current: 1.47 Distance: 261 Voltage Drop: End of Line Voltage: 18.35 2.05 CIRCUIT IS WITHIN LIMITS Percent Drop: 5.77% Load Centering Method Current: 1.47 261 19.22 Distance: Voltage Drop: End of Line Voltage: 1.18 CIRCUIT 1S WITHIN LIMITS Percent Drop: 11.55% End of Line Method Current: 1.47 261 18.04 Distance: Voltage Drop: End of Line Voltage: 2.36 Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP5 Circuit: NAC3 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.555 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guaae Ohms/ 1000' 64 14 3.07 158 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 5.3.1 P 110 0.245 64 19.789 0.611 0.0300 5.3.2 P 110 0.245 9 19.717 0.683 0.0335 5.3.3 H 15 0.085 7 19.671 0.729 0.0357 5.3.4 P 110 0.245 20 19.550 0.850 0.0416 5.3.5 P 110 0.245 19 19.465 0.935 0.0458 5.3.6 P 110 0.245 23 19.395 1.005 0.0492 5.3.7 P 110 0.245 80 19.275 1.125 0.0551 END Z 0.000 0 19.275 1.125 0.0551 END Z 0.000 0 19.275 1.125 0.0551 END Z 0.000 0 19.275 1.125 0.0551 END Z 0.000 0 19.275 1.125 0.0551 END Z 0.000 0 19.275 1.125 0.0551 END Z 0.000 0 19.275 1.125 0.0551 END Z 0.000 0 19.275 1.125 0.0551 END Z 0.000 0 19.275 1.125 0.0551 END Z 0.000 0 19.275 1.125 0.0551 END Z 0.000 0 19.275 1.125 0.0551 END Z 0.000 0 19.275 1.125 0.0551 END Z 0.000 0 19.275 1.125 0.0551 END Z 0.000 0 19.275 1.125 0.0551 END Z 0.000 0 19.275 1.125 0.0551 Totals: 1.555 222 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 5.51% Current: 1.555 Distance: 222 End Line Voltage: Voltage Drop: 1.12 of 19.28 CIRCUIT IS WITHIN LIMITS Percent Drop: 5.20% Load Centering Method Current: 1.555 Distance: Voltage Drop: 222 End of Line Voltage: 19.34 1.06 CIRCUIT IS WITHIN LIMITS Percent Drop: 10.39% End of Line Method Current: 1.555 222 18.28 Distance: Voltage Drop: End of Line Voltage: 2.12 PrOiect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP5 Circuit: NAC4 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.012 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guaae Ohms/ 1000' 37 14 3.07 212 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device. Voltage Drop Voltage at Drop From Device Source Percent Drop 5.4.1 D 0.092 37 20.170 0.230 0.0113 5.4.2 D 0.092 17 20.074 0.326 0.0160 5.4.3 D 0.092 24 19.952 0.448 0.0220 5.4.4 D 0.092 16 19.880 0.520 0.0255 5.4.5 D 0.092 24 19.785 0.615 0.0302 5.4.6 D 0.092 17 19.727 0.673 0.0330 5.4.7 D 0.092 19 19.674 0.726 0.0356 5.4.8 D 0.092 24 19.619 0.781 0.0383 5.4.9 D 0.092 22 19.582 0.818 0.0401 5.4.10 D 0.092 29 19.549 0.851 0.0417 5.4.11 D 0.092 20 19.538 0.862 0.0423 END Z 0.000 0 19.538 0.862 0.0423 END Z 0.000 0 19.538 0.862 0.0423 END Z 0.000 0 19.538 0.862 0.0423 END Z 0.000 0 19.538 0.862 0.0423 END Z 0.000 0 19.538 0.862 0.0423 END Z 0.000 0 19.538 0.862 0.0423 END Z 0.000 0 19.538 0.862 0.0423 END Z 0.000 0 19.538 0.862 0.0423 END Z 0.000 0 19.538 0.862 0.0423 END Z 0.000 0 19.538 0.862 0.0423 Totals: 1.012 249 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 4.23% Current: 1.012 Distance: 249 Voltage Drop: End of Line Voltage: 19.54 0.86 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 3.79% Current: 1.012 Distance: 249 Voltage Drop: End of Line Voltage: 19.63 0.77 End Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 7.58% Current: 1.012 of Distance: 249 Voltage Drop: End of Line Voltage: 18.85 1.55 Pr01ect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP5 Battery Calculations Standy Circuit / Device Current Alarm Current Qty Total Standy Current Total Alarm Current Power Supply 70 70 1 70 70 NAC Power NAC1 0 1470 1 0 1470 NAC2 0 1470 1 0 1470 NAC3 0 1555 1 0 1555 NAC4 66 1012 1 66 0 200 mA Aux Power Aux 0 0 0 0 0 Aux 0 0 0 0 0 Aux 0 0 0 0 0 TOTALS: 136 4565 Total Standy Current (Amps): 0.136 X 24 Hours: 3.264 Amphours in Standy Total Alarm Current (Amps): 4.565 X 15 Mins: 1.14 Amphours in Alarm 4.41 Required Amphours +20% Safety Total Required Amphours: 4.41 Margin 5'29 Amphours hours (2) 12V 8Ah Batteries Required. `Magnetic Door Holders are not included in the battery calculations. Power to these devices will be automatically disconnected upon loss of NC power to reduce battery size. DEVICE LEGEND Devices Current (Milliamps) Designator Part Number Description LightOuput 0 15cd 30cd 75cd 95cd 110cd 177cd -<X*<c-iw O-0OZKr c--=Ommo0aoD SB4U SB4U-LF GSA-SBT SIGA-AB4G-LF INT-7ATW INT-8ATW EG1 F-HD EG1F-VM EG1F-HDVM EGCF-VM EGCF-VMH EGCF-HDVM EGCF-HDVMH G4LFWF-H G4LFWF-HVM G4HFWF-S7VMC GCHFWF-S7VMC INT-4ASW XXXX DHF-24120C C01224T XXXX XXXX XXXX XXXX Sounder Base for V Series Detectors 520Hz Sounder Base for V Series Detectors Sounder Base for PCOS Detectors 520Hz Sounder Base for PCOS Detectors WP Wall Mount Horn/Strobe WP Wall Mount Horn/Strobe Wall Mount Horn Wall Mount Strobe Wall Mount Horn/Strobe Ceiling Mount Strobe Ceiling Mount High Candela Strobe Ceiling Mount Horn/Strobe Ceiling Mount High Candela Horn/Strobe Wall Mount 520Hz Horn Wall Mount 520Hz Horn/Strobe Wall Mount Speaker/Strobe Ceiling Mount Speaker/Strobe Weatherproof Speaker/Strobe XXXX Magnetic Door Hold-Open Carbon Monoxide Detector XXXX XXXX XXXX XXXX 28 92 52 92 180 90 22 85 127 245 285 102 135 160 246 309 94 140 273 325 333 551 111 152 281 333 324 554 166 219 266 381 437 78 101 188 245 94 140 273 325 551 159 15 75 Z N/A END OF CIRCUIT Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP6 Circuit: NAC1 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0.491 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 8 14 3.07 210 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Percent Device Source Drop 6.1.1 P 15 0.078 8 20.376 0.024 0.0012 6.1.2 P 30 0.101 28 20.305 0.095 0.0047 6.1.3 P 15 0.078 29 20.249 0.151 0.0074 6.1.4 P 15 0.078 52 20.175 0.225 0.0110 6.1.5 P 15 0.078 50 20.127 0.273 0.0134 6.1.6 P 15 0.078 51 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 Totals: 0.491 218 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 1.46% Current: 0.491 Distance: 218 End Line Voltage Drop: 0.30 of Voltage: 20.10 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop:1.61% Current: I 0.491 1 218 20.07 Distance:1 Voltage Drop: End of Line Voltage: 0.33 End of Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 3.22% Current:; 0.491 Distance: 218 End Volta 9 a Dro p:, 0.66 of Line Voltage: 19.74 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP6 Circuit: NAC2 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 2.13 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 31 14 3.07 123 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 6.2.1 P 110 0.245 31 19.995 0.405 0.0199 6.2.2 P 110 0.245 9 19.890 0.510 0.0250 6.2.3 H 15 0.085 19 19.699 0.701 0.0344 6.2.4 P 110 0.245 8 19.623 0.777 0.0381 6.2.5 P 110 0.245 7 19.566 0.834 0.0409 6.2.6 P 110 0.245 9 19.508 0.892 0.0437 6.2.7 H 15 0.085 12 19.447 0.953 0.0467 6.2.8 P 110 0.245 43 19.253 1.147 0.0562 6.2.9 P 110 0.245 9 19.226 1.174 0.0575 6.2.10 P 110 0.245 7 19.215 1.185 0.0581 END Z 0.000 0 19.215 1.185 0.0581 END Z 0.000 0 19.215 1.185 0.0581 END Z 0.000 0 19.215 1.185 0.0581 END Z 0.000 0 19.215 1.185 0.0581 END Z 0.000 0 19.215 1.185 0.0581 END Z 0.000 0 19.215 1.185 0.0581 END Z 0.000 0 19.215 1.185 0.0581 END Z 0.000 0 19.215 1.185 0.0581 END Z 0.000 0 19.215 1.185 0.0581 END Z 0.000 0 19.215 1.185 0.0581 END Z 0.000 0 19.215 1.185 0.0581 T+I40:Q42otals: 2.13 154 CIRCUIT IS WITHIN LIMITS Percent Drop: 5.81% Point to Point Method Current: 2.13 154 19.22 Distance: Voltage Drop: End of Line Voltage: 1.18 CIRCUIT IS WITHIN LIMITS Percent Drop: 4.94% Load Centering Method Current: 2.13 154 19.39 Distance: Voltage Drop: End of Line Voltage: 1.01 CIRCUIT IS WITHIN LIMITS Percent Drop: 9.87% End of Line Method Current: 2.13 154 18.39 Distance: Voltage Drop: End of Line Voltage: 2.01 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP6 Circuit: NAC3 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guaae Ohms/ 1000' 0 14 3.07 0 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 Totals: 0 0 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 Distance: 0 End Line Voltage: Voltage Drop: 0.00 of 20.40 Load Centering Method CIRCUIT IS WITHIN LIMITSI Percent Drop: 0.00% Current: 0 0 20.40 Distance: Voltage Drop: End of Line Voltage: 0.00 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% End of Line Method Current: 0 0 20.40 Distance: Voltage Drop: End of Line Voltage: 0.00 Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP6 Circuit: NAC4 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.288 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guaae Ohms/ 1000' 28 14 3.07 326 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 6.4.1 D 0.092 28 20.179 0.221 0.0109 6.4.2 D 0.092 21 20.024 0.376 0.0184 6.4.3 D 0.092 16 19.916 0.484 0.0237 6.4.4 D 0.092 21 19.785 0.615 0.0301 6.4.5 D 0.092 24 19.650 0.750 0.0368 6.4.6 D 0.092 19 19.553 0.847 0.0415 6.4.7 D 0.092 23 19.449 0.951 0.0466 6.4.8 D 0.092 81 19.129 1.271 0.0623 6.4.9 D 0.092 20 19.061 1.339 0.0656 6.4.10 D 0.092 25 18.991 1.409 0.0691 6.4.11 D 0.092 21 18.943 1.457 0.0714 6.4.12 D 0.092 12 18.923 1.477 0.0724 6.4.13 D 0.092 21 18.899 1.501 0.0736 6.4.14 D 0.092 22 18.887 1.513 0.0742 END Z 0.000 0 18.887 1.513 0.0742 END Z 0.000 0 18.887 1.513 0.0742 END Z 0.000 0 18.887 1.513 0.0742 END Z 0.000 0 18.887 1.513 0.0742 END Z 0.000 0 18.887 1.513 0.0742 END Z 0.000 0 18.887 1.513 0.0742 END Z 0.000 0 18.887 1.513 0.0742 Totals: 1.288 354 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 7.42% Current: 1.288 Distance: 354 Voltage Drop: End of Line Voltage: 18.89 1.51 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 6.86% Current: 1.288 Distance: 354 Voltage Drop: End of Line Voltage: 19.00 1.40 End Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 13.72% Current: 1.288 of Distance: 354 Voltage Drop: End of Line Voltage: 17.60 _ 2.80 Prosect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP6 Battery Calculations Standy Circuit / Device Current Alarm Current Qty Total Standy Current Total Alarm Current Power Supply 70 70 1 70 70 NAC Power NAC1 0 491 1 0 491 NAC2 0 2130 1 0 2130 NAC3 0 0 0 0 0 NAC4 84 1288 1 84 0 200 mA Aux Power Aux 0 0 0 0 0 Aux 0 0 0 0 0 Aux 0 0 0 0 0 TOTALS: 154 2691 Total Standy Current (Amps): 0.154 X 24 Hours: 3.696 Amphours in Standy Total Alarm Current (Amps): 2.691 X 15 Mins: 0.67 Amphours in Alarm 4.37 Required Amphours Required Amphours: +20% Safety 4.37 5'24 Total Margin Am hours p (2) 12V 8Ah Batteries Required. "Magnetic Door Holders are not included in the battery calculations. Power to these devices will be automatically disconnected upon loss of A/C power to reduce battery size. DEVICE LEGEND Devices Current (Milliamps) Designator Part Number Description Light Ouput 0 15cd 30cd 75cd 95cd 110cd 177cd A B C D E F G H I J K L M N 0 P Q R S T U V W X Y SB4U SB4U-LF GSA-SBT SIGA-AB4G-LF INT-7ATW INT-8ATW EG1F-HD EG1F-VM EG1F-HDVM EGCF-VM EGCF-VMH EGCF-HDVM EGCF-HDVMH G4LFWF-H G4LFWF-HVM G4HFWF-S7VMC GCHFWF-S7VMC INT-4ASW XXXX DHF-24120C C01224T XXXX XXXX XXXX XXXX Sounder Base for V Series Detectors 520Hz Sounder Base for V Series Detectors Sounder Base for PCOS Detectors 520Hz Sounder Base for PCOS Detectors WP Wall Mount Horn/Strobe WP Wall Mount Horn/Strobe Wall Mount Horn Wall Mount Strobe Wall Mount Horn/Strobe Ceiling Mount Strobe Ceiling Mount High Candela Strobe Ceiling Mount Horn/Strobe Ceiling Mount High Candela Horn/Strobe Wall Mount 520Hz Horn Wall Mount 520Hz Horn/Strobe Wall Mount Speaker/Strobe Ceiling Mount Speaker/Strobe Weatherproof Speaker/Strobe XXXX Magnetic Door Hold-Open Carbon Monoxide Detector XXXX XXXX XXXX XXXX 28 92 52 92 180 90 22 85 127 245 285 102 135 160 246 309 94 140 273 325 333 551 111 152 281 333 324 554 166 219 266 381 437 78 101 188 245 94 140 273 325 551 159 15 75 Z N/A END OF CIRCUIT Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP7 Circuit: NAC1 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.225 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 136 14 3.07 81 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 7.1.1 P 110 0.245 136 19.377 1.023 0.0501 7.1.2 P 110 0.245 22 19.245 1.155 0.0566 7.1.3 P 110 0.245 19 19.159 1.241 0.0608 7.1.4 P 110 0.245 22 19.093 1.307 0.0641 7.1.5 P 110 0.245 18 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 Totals: 1.225 217 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 6.54% Current:. 1.225 Distance: 217 End Line Voltage: Voltage Drop: 1.33 of 19.07 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 4.00% Current:! 1.225 217 19.58 Distance: Voltage Drop: End of Line Voltage: 0.82 End of Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 8.00% Current: 1.225 Distance: 217 End Line Voltage: 18.77 Voltage Drop: 1.63 of Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP7 Circuit: NAC2 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.225 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guage Ohms/ 1000' 56 14 3.07 101 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 7.2.1 P 110 0.245 56 19.979 0.421 0.0206 7.2.2 P 110 0.245 32 19.786 0.614 0.0301 7.2.3 P 110 0.245 9 19.746 0.654 0.0321 7.2.4 P 110 0.245 35 19.640 0.760 0.0372 7.2.5 P 110 0.245 25 19.603 0.797 0.0391 END Z 0.000 0 19.603 0.797 0.0391 END Z 0.000 0 19.603 0.797 0.0391 END Z 0.000 0 19.603 0.797 0.0391 END Z 0.000 0 19.603 0.797 0.0391 END Z 0.000 0 19.603 0.797 0.0391 END Z 0.000 0 19.603 0.797 0.0391 END Z 0.000 0 19.603 0.797 0.0391 END Z 0.000 0 19.603 0.797 0.0391 END Z 0.000 0 19.603 0.797 0.0391 END Z 0.000 0 19.603 0.797 0.0391 END Z 0.000 0 19.603 0.797 0.0391 END Z 0.000 0 19.603 0.797 0.0391 END Z 0.000 0 19.603 0.797 0.0391 END Z 0.000 0 19.603 0.797 0.0391 END Z 0.000 0 19.603 0.797 0.0391 END Z 0.000 0 19.603 0.797 0.0391 T+I40:Q42otals: 1.225 157 CIRCUIT IS WITHIN LIMITS Percent Drop: 3.91% Current: 1.225 Point to Point Method 157 19.60 Distance: Voltage Drop: End of Line Voltage: 0.80 CIRCUIT IS WITHIN LIMITS Percent Drop: 2.89% Load Centering Method Current: 1.225 157 19.81 Distance: Voltage Drop: End of Line Voltage: 0.59 CIRCUIT IS WITHIN LIMITS Percent Drop: 5.79% End of Line Method Current: 1.225 157 19.22 Distance: Voltage Drop: End of Line Voltage: 1.18 Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP7 Circuit: NAC3 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0.491 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guaae Ohms/ 1000' 6 14 3.07 205 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 7.3.1 P 30 0.101 6 20.382 0.018 0.0009 7.3.2 P 15 0.078 16 20.344 0.056 0.0028 7.3.3 P 15 0.078 52 20.244 0.156 0.0076 7.3.4 P 15 0.078 53 20.168 0.232 0.0114 7.3.5 P 15 0.078 54 20.116 0.284 0.0139 7.3.6 P 15 0.078 30 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 END Z 0.000 0 20.102 0.298 0.0146 Totals: 0.491 211 CIRCUIT IS WITHIN LIMITS 1.46% Current: Percent Drop: 0.491 Point to Point Method Distance: 211 End Line Voltage: Voltage Drop: 20.10 of 0.30 Load Centering Method CIRCUIT IS WITHIN LIMITS 1.56% Current: Percent Drop: 0.491 211 End Line Voltage: 20.08 Distance: Voltage Drop: of 0.32 CIRCUIT IS WITHIN LIMITS Percent 3.12% Current: Drop: 0.491 1 End of Line Method Distance: 211 End Line Voltage: Voltage Drop: of 0.64 19.76 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP7 Circuit: NAC4 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guaae Ohms/ 1000' 0 14 3.07 0 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 Totals: 0 0 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 Distance: 0 Voltage Drop: End of Line Voltage: 20.40 0.00 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 Distance: 0 _ Voltage Drop: End of Line Voltage: 20.40 0.00 End Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 of Distance: 0 Voltage Drop: End of Line Voltage: 20.40 0.00 Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP7 Battery Calculations Circuit / Device Standy Current Alarm Current Qty Total Standy Current Total Alarm Current Power Supply 70 70 1 70 70 NAC Power NAC1 0 1225 1 0 1225 NAC2 0 1225 1 0 1225 NAC3 0 491 1 0 491 NAC4 0 0 0 0 0 200 mA Aux Power Aux 0 0 0 0 0 Aux 0 0 0 0 0 Aux 0 0 0 0 0 TOTALS: 70 3011 Total Standy Current (Amps): 0.07 X 24 Hours: 1.68 Amphours in Standy Total Alarm Current (Amps): 3.011 X 15 Mins: 0.75 Amphours in Alarm 2.43 Required Amphours Required Amphours: +20% Safety 2.43 2'92 Total Margin Am hours p (2) 12V 3Ah Batteries Required. *Magnetic Door Holders are not included in the battery calculations. Power to these devices will be automatically disconnected upon loss of NC power to reduce battery size. DEVICE LEGEND Devices Current (Milliamps) Designator Part Number Description Light Ouput 0 15cd 30cd 75cd 95cd 110cd 177cd A B C D E F G H I J K L M N O P Q R S T U V W X Y SB4U SB4U-LF GSA-SBT SIGA-AB4G-LF INT-7ATW INT-8ATW EG1F-HD EG1F-VM EG1F-HDVM EGCF-VM EGCF-VMH EGCF-HDVM EGCF-HDVMH G4LFWF-H G4LFWF-HVM G4HFWF-S7VMC GCHFWF-S7VMC INT-4ASW XXXX DHF-24120C CO1224T XXXX XXXX XXXX XXXX Sounder Base for V Series Detectors 520Hz Sounder Base for V Series Detectors Sounder Base for PCOS Detectors 520Hz Sounder Base for PCOS Detectors WP Wall Mount Horn/Strobe WP Wall Mount Horn/Strobe Wall Mount Horn Wall Mount Strobe Wall Mount Horn/Strobe Ceiling Mount Strobe Ceiling Mount High Candela Strobe Ceiling Mount Horn/Strobe Ceiling Mount High Candela Horn/Strobe Wall Mount 520Hz Horn Wall Mount 520Hz Horn/Strobe Wall Mount Speaker/Strobe Ceiling Mount Speaker/Strobe Weatherproof Speaker/Strobe XXXX Magnetic Door Hold-Open Carbon Monoxide Detector XXXX XXXX XXXX XXXX 28 92 52 92 180 90 22 85 127 245 285 309 102 135 160 246 94 140 273 325 333 551 111 152 281 333 324 554 166 219 266 381 437 78 101 188 245 94 140 273 325 551 159 15 75 Z N/A END OF CIRCUIT Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP8 Circuit: NAC1 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.47 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 103 14 3.07 128 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 8.1.1 P 110 0.245 103 19.470 0.930 0.0456 8.1.2 P 110 0.245 26 19.275 1.125 0.0552 8.1.3 P 110 0.245 21 19.148 1.252 0.0614 8.1.4 P 110 0.245 37 18.981 1.419 0.0695 8.1.5 P 110 0.245 21 18.918 1.482 0.0726 8.1.6 P 110 0.245 23 18.884 1.516 0.0743 END Z 0.000 0 18.884 1.516 0.0743 END Z 0.000 0 18.884 1.516 0.0743 END Z 0.000 0 18.884 1.516 0.0743 END Z 0.000 0 18.884 1.516 0.0743 END Z 0.000 0 18.884 1.516 0.0743 END Z 0.000 0 18.884 1.516 0.0743 END Z 0.000 0 18.884 1.516 0.0743 END Z 0.000 0 18.884 1.516 0.0743 END Z 0.000 0 18.884 1.516 0.0743 END Z 0.000 0 18.884 1.516 0.0743 END Z 0.000 0 18.884 1.516 0.0743 END Z 0.000 0 18.884 1.516 0.0743 END Z 0.000 0 18.884 1.516 0.0743 END Z 0.000 0 18.884 1.516 0.0743 END Z 0.000 0 18.884 1.516 0.0743 Totals: 1.47 231 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 7.43% Current: 1.47 Distance: 231 End Line Voltage: Voltage Drop: 1.52 of 18.88 CIRCUIT IS WITHIN LIMITS Load Centering Method Current:'. 1.47 Percent Drop: 5.11 % 231 19.36 Distance: Voltage Drop: End of Line Voltage: 1.04 CIRCUIT IS WITHIN LIMITS Percent Drop: 10.22% End of Line Method Current: 1.47 231 18.32 Distance: Voltage Drop: End of Line Voltage: 2.08 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP8 Circuit: NAC2 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.31 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guage Ohms/ 1000' 12 14 3.07 106 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 8.2.1 P 110 0.245 12 20.303 0.097 0.0047 8.2.2 P 110 0.245 26 20.133 0.267 0.0131 8.2.3 P 110 0.245 22 20.023 0.377 0.0185 8.2.4 P 110 0.245 9 19.991 0.409 0.0201 8.2.5 P 110 0.245 41 19.908 0.492 0.0241 8.2.6 H 15 0.085 8 19.904 0.496 0.0243 END Z 0.000 0 19.904 0.496 0.0243 END Z 0.000 0 19.904 0.496 0.0243 END Z 0.000 0 19.904 0.496 0.0243 END Z 0.000 0 19.904 0.496 0.0243 END Z 0.000 0 19.904 0.496 0.0243 END Z 0.000 0 19.904 0.496 0.0243 END Z 0.000 0 19.904 0.496 0.0243 END Z 0.000 0 19.904 0.496 0.0243 END Z 0.000 0 19.904 0.496 0.0243 END Z 0.000 0 19.904 0.496 0.0243 END Z 0.000 0 19.904 0.496 0.0243 END Z 0.000 0 19.904 0.496 0.0243 END Z 0.000 0 19.904 0.496 0.0243 END Z 0.000 0 19.904 0.496 0.0243 END Z 0.000 0 19.904 0.496 0.0243 T+I40:Q42otals: 1.31 118 CIRCUIT IS WITHIN LIMITS Percent Drop: 2.43% Point to Point Method Current: 1.31 118 19.90 Distance: Voltage Drop: End of Line Voltage: 0.50 CIRCUIT IS WITHIN LIMITS Percent Drop: 2.33% Load Centering Method Current: 1.31 118 19.93 Distance: Voltage Drop: End of Line Voltage: 0.47 CIRCUIT IS WITHIN LIMITS Percent Drop: 4.65% Current: 1.31 End of Line Method 118 19.45 Distance: Voltage Drop: End of Line Voltage: 0.95 Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP8 Circuit: NAC3 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.225 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guacie Ohms/ 1000" 152 14 3.07 76 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 8.3.1 P 110 0.245 152 19.257 1.143 0.0560 8.3.2 P 110 0.245 19 19.142 1.258 0.0616 8.3.3 P 110 0.245 9 19.102 1.298 0.0636 8.3.4 P 110 0.245 39 18.984 1.416 0.0694 8.3.5 P 110 0.245 9 18.971 1.429 0.0701 END Z 0.000 0 18.971 1.429 0.0701 END Z 0.000 0 18.971 1.429 0.0701 END Z 0.000 0 18.971 1.429 0.0701 END Z 0.000 0 18.971 1.429 0.0701 END Z 0.000 0 18.971 1.429 0.0701 END Z 0.000 0 18.971 1.429 0.0701 END Z 0.000 0 18.971 1.429 0.0701 END Z 0.000 0 18.971 1.429 0.0701 END Z 0.000 0 18.971 1.429 0.0701 END Z 0.000 0 18.971 1.429 0.0701 END Z 0.000 0 18.971 1.429 0.0701 END Z 0.000 0 18.971 1.429 0.0701 END Z 0.000 0 18.971 1.429 0.0701 END Z 0.000 0 18.971 1.429 0.0701 END Z 0.000 0 18.971 1.429 0.0701 END Z 0.000 0 18.971 1.429 0.0701 Totals: 1.225 228 CIRCUIT IS WITHIN LIMITS Percent Drop: 7.01% Point to Point Method Current: 1.225 228 18.97 Distance: Voltage Drop: End of Line Voltage: 1.43 CIRCUIT IS WITHIN LIMITS Percent Drop: 4.20% Load Centering Method Current: 1.225 Distance: Voltage Drop: 228 End of Line Voltage: 19.54 0.86 End of Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 8.41% Current: 1.225 Distance: 228 Voltage Drop: End of Line Voltage: 18.69 1.71 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP8 Circuit: NAC4 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.012 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guaae Ohms / 1000' 16 14 3.07 241 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 8.4.1 D 0.092 16 20.301 0.099 0.0049 8.4.2 D 0.092 18 20.199 0.201 0.0099 8.4.3 D 0.092 31 20.041 0.359 0.0176 8.4.4 D 0.092 15 19.974 0.426 0.0209 8.4.5 D 0.092 23 19.883 0.517 0.0254 8.4.6 D 0.092 28 19.788 0.612 0.0300 8.4.7 D 0.092 18 19.737 0.663 0.0325 8.4.8 D 0.092 27 19.676 0.724 0.0355 8.4.9 D 0.092 28 19.628 0.772 0.0378 8.4.10 D 0.092 24 19.601 0.799 0.0392 8.4.11 D 0.092 29 19.585 0.815 0.0400 END Z 0.000 0 19.585 0.815 0.0400 END Z 0.000 0 19.585 0.815 0.0400 END Z 0.000 0 19.585 0.815 0.0400 END Z 0.000 0 19.585 0.815 0.0400 END Z 0.000 0 19.585 0.815 0.0400 END Z 0.000 0 19.585 0.815 0.0400 END Z 0.000 0 19.585 0.815 0.0400 END Z 0.000 0 19.585 0.815 0.0400 END Z 0.000 0 19.585 0.815 0.0400 END Z 0.000 0 19.585 0.815 0.0400 Totals: 1.012 257 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 4.00% Current: Distance: 1.012 257 Voltage Drop: End of Line Voltage: 19.58 0.82 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 3.91% Current: 1.012 Distance: 257 Voltage Drop: End of Line Voltage: 19.60 0.80 End of Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 7.83% Current: Distance: 1.012 257 Voltage Drop: End of Line Voltage: 18.80 1.60 Prosect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP8 Battery Calculations Standy Circuit / Device Current Alarm Current Qty Total Standy Current Total Alarm Current Power Supply 70 70 1 70 70 NAC Power NAC1 0 1470 1 0 1470 NAC2 0 1310 1 0 1310 NAC3 0 1225 1 0 1225 NAC4 66 1012 1 66 0 200 mA Aux Power Aux 0 0 0 0 0 Aux 0 0 0 0 0 Aux 0 0 0 0 0 TOTALS: 136 4075 Total Standy Current (Amps): 0.136 X 24 Hours: 3.264 Amphours in Standy Total Alarm Current (Amps): 4.075 X 15 Mins: 1.02 Amphours in Alarm 4.28 Required Amphours Required Amphours: +20% Safety 4.28 5.14 Total Margin Am hours p (2) 12V 8Ah Batteries Required. "Magnetic Door Holders are not included in the battery calculations. Power to these devices will be automatically disconnected upon Toss of A/C power to reduce battery size. DEVICE LEGEND Devices Current (Milliamps) Designator Part Number Description LightOuput 0 15cd 30cd 75cd 95cd 110cd 177cd A B C D E F G H I J K L M N 0 P Q R S T U V W X Y SB4U SB4U-LF GSA-SBT SIGA-AB4G-LF INT-7ATW INT-8ATW EG1F-HD EG1F-VM EG1F-HDVM EGCF-VM EGCF-VMH EGCF-HDVM EGCF-HDVMH G4LFWF-H G4LFWF-HVM G4HFWF-S7VMC GCHFWF-S7VMC INT-4ASW XXXX DHF-24120C C01224T XXXX XXXX )(XXX XXXX Sounder Base for V Series Detectors 520Hz Sounder Base for V Series Detectors Sounder Base for PCOS Detectors 520Hz Sounder Base for PCOS Detectors WP Wall Mount Horn/Strobe WP Wall Mount Horn/Strobe Wall Mount Horn Wall Mount Strobe Wall Mount Horn/Strobe Ceiling Mount Strobe Ceiling Mount High Candela Strobe Ceiling Mount Horn/Strobe Ceiling Mount High Candela Horn/Strobe Wall Mount 520Hz Horn Wall Mount 520Hz Horn/Strobe Wall Mount Speaker/Strobe Ceiling Mount Speaker/Strobe Weatherproof Speaker/Strobe XXXX Magnetic Door Hold-Open Carbon Monoxide Detector )(XXX )(XXX )00( )(XXX 28 92 52 92 180 90 22 _ 85 127 245 285 102 135 160 246 309 94 140 273 325 333 551 111 152 281 333 324 554 166 219 266 381 437 78 101 188 245 94 140 273 325 551 159 15 75 Z N/A END OF CIRCUIT Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP9 Circuit: NAC1 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.47 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 36 14 3.07 104 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 9.1.1 P 110 0.245 36 20.075 0.325 0.0159 9.1.2 P 110 0.245 20 19.925 0.475 0.0233 9.1.3 P 110 0.245 22 19.792 0.608 0.0298 9.1.4 P 110 0.245 20 19.702 0.698 0.0342 9.1.5 P 110 0.245 23 19.633 0.767 0.0376 9.1.6 P 110 0.245 19 19.604 0.796 0.0390 END Z 0.000 0 19.604 0.796 0.0390 END Z 0.000 0 19.604 0.796 0.0390 END Z 0.000 0 19.604 0.796 0.0390 END Z 0.000 0 19.604 0.796 0.0390 END Z 0.000 0 19.604 0.796 0.0390 END Z 0.000 0 19.604 0.796 0.0390 END Z 0.000 0 19.604 0.796 0.0390 END Z 0.000 0 19.604 0.796 0.0390 END ' Z 0.000 0 19.604 0.796 0.0390 END Z 0.000 0 19.604 0.796 0.0390 END Z 0.000 0 19.604 0.796 0.0390 END Z 0.000 0 19.604 0.796 0.0390 END Z 0.000 0 19.604 0.796 0.0390 END Z 0.000 0 19.604 0.796 0.0390 END Z 0.000 0 19.604 0.796 0.0390 Totals: 1.47 140 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 3.90% Current: 1.47 Distance: 140 End Line Voltage Drop: 0.80 of Voltage: 19.60 CIRCUIT IS WITHIN LIMITS Percent Drop: 3.10% Load Centering Method Current: 1.47 140 19.77 Distance: Voltage Drop: End of Line Voltage: 0.63 End of Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 6.19% Current: 1.47 Distance: 140 End Line Voltage: Voltage Drop: 1.26 of 19.14 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP9 Circuit: NAC2 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.715 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 167 14 3.07 95 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 9.2.1 P 110 0.245 167 18.641 1.759 0.0862 9.2.2 P 110 0.245 19 18.470 1.930 0.0946 9.2.3 P 110 0.245 18 18.335 2.065 0.1012 9.2.4 P 110 0.245 9 18.280 2.120 0.1039 9.2.5 P 110 0.245 33 18.132 2.268 0.1112 9.2.6 P 110 0.245 9 18.104 2.296 0.1125 9.2.7 P 110 0.245 7 18.094 2.306 0.1130 END Z 0.000 0 18.094 2.306 0.1130 END Z 0.000 0 18.094 2.306 0.1130 END Z 0.000 0 18.094 2.306 0.1130 END Z 0.000 0 18.094 2.306 0.1130 END Z 0.000 0 18.094 2.306 0.1130 END Z 0.000 0 18.094 2.306 0.1130 END Z 0.000 0 18.094 2.306 0.1130 END Z 0.000 0 18.094 2.306 0.1130 END Z 0.000 0 18.094 2.306 0.1130 END Z 0.000 0 18.094 2.306 0.1130 END Z 0.000 0 18.094 2.306 0.1130 END Z 0.000 0 18.094 2.306 0.1130 END Z 0.000 0 18.094 2.306 0.1130 END Z 0.000 0 18.094 2.306 0.1130 T+I40:Q42otais: 1.715 262 CIRCUIT IS WITHIN LIMITS Percent Drop: 11.30% Current: 1.715 Point to Point Method 262 18.09 Distance: Voltage Drop: End of Line Voltage: 2.31 CIRCUIT IS WITHIN LIMITS Percent Drop: 6.76% Load Centering Method Current: 1.715 262 19.02 Distance: End of Line Voltage: 1.38 Voltage Drop: CIRCUIT IS WITHIN LIMITS Percent Drop: 13.52% Current: 1.715 End of Line Method 262 17.64 Distance: Voltage Drop: End of Line Voltage: 2.76 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP9 Circuit: NAC3 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.225 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guaae Ohms/ 1000' 135 14 3.07 84 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 9.3.1 P 110 0.245 135 19.385 1.015 0.0498 9.3.2 P 110 0.245 23 19.246 1.154 0.0566 9.3.3 P 110 0.245 20 19.156 1.244 0.0610 9.3.4 P 110 0.245 19 19.099 1.301 0.0638 9.3.5 P 110 0.245 22 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 END Z 0.000 0 19.066 1.334 0.0654 Totals: 1.225 219 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 6.54% Current: 1.225 Distance: 219 End Line Voltage: Voltage Drop: 1.33 of 19.07 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 4.04% Current: 1.225 Distance: 219 End Line Voltage Drop: 0.82 of Voltage: 19.58 End Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 8.07% Current: 1.225 of Distance: 219 End Line Voltage: Voltage Drop: 1.65 of 18.75 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP9 Circuit: NAC4 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.012 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guaae Ohms / 1000' 34 14 3.07 206 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 9.4.1 D 0.092 34 20.189 0.211 0.0104 9.4.2 D 0.092 20 20.076 0.324 0.0159 9.4.3 D 0.092 21 19.969 0.431 0.0211 9.4.4 D 0.092 20 19.879 0.521 0.0256 9.4.5 D 0.092 23 19.788 0.612 0.0300 9.4.6 D 0.092 19 19.723 0.677 0.0332 9.4.7 D 0.092 19 19.670 0.730 0.0358 9.4.8 D 0.092 22 19.620 0.780 0.0382 9.4.9 D 0.092 19 19.588 0.812 0.0398 9.4.10 D 0.092 25 19.559 0.841 0.0412 9.4.11 D 0.092 18 19.549 0.851 0.0417 END Z 0.000 0 19.549 0.851 0.0417 END Z 0.000 0 19.549 0.851 0.0417 END Z 0.000 0 19.549 0.851 0.0417 END Z 0.000 0 19.549 0.851 0.0417 END Z 0.000 0 19.549 0.851 0.0417 END Z 0.000 0 19.549 0.851 0.0417 END Z 0.000 0 19.549 0.851 0.0417 END Z 0.000 0 19.549 0.851 0.0417 END Z 0.000 0 19.549 0.851 0.0417 END Z 0.000 0 19.549 0.851 0.0417 Totals: 1.012 240 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 4.17% Current: 1.012 Distance: 240 Voltage Drop: End of Line Voltage: 19.55 0.85 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 3.66% Current: 1.012 Distance: 240 Voltage Drop: End of Line Voltage: 19.65 0.75 End Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 7.31% Current: 1.012 of Distance: 240 Voltage Drop: End of Line Voltage: 18.91 1.49 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP9 Battery Calculations Standy Circuit / Device Current Alarm Current Qty Total Standy Current Total Alarm Current Power Supply 70 70 1 70 70 NAC Power NAC1 0 1470 1 0 1470 NAC2 0 1715 1 0 1715 NAC3 0 1225 1 0 1225 NAC4 66 1012 1 66 0 200 mA Aux Power Aux 0 0 0 0 0 Aux 0 0 0 0 0 Aux 0 0 0 0 0 TOTALS: 136 4480 Total Standy Current (Amps): 0.136 X 24 Hours: 3.264 Amphours in Standy Total Alarm Current (Amps): 4.48 X 15 Mins: 1.12 Amphours in Alarm 4.38 Required Amphours Required Amphours: +20% Safety 4.38 5'26 Total Margin Am hour's p (2) 12V 8Ah Batteries Required. *Magnetic Door Holders are not included in the battery calculations. Power to these devices will be automatically disconnected upon loss of NC power to reduce battery size. DEVICE LEGEND Devices Current (Milliamps) Designator Part Number Description Light Ouput 0 15cd 30cd 75cd 95cd 110cd 177cd A B C D E F G H I J K L M N 0 P Q R S T U V W X Y SB4U SB4U-LF GSA-SBT SIGA-AB4G-LF INT-7ATW INT-8ATW EG1F-HD EG1 F-VM EG1F-HDVM EGCF-VM EGCF-VMH EGCF-HDVM EGCF-HDVMH G4LFWF-H G4LFWF-HVM G4HFWF-S7VMC GCHFWF-S7VMC INT-4ASW XXXX DHF-24120C C01224T XXXX XXXX XXXX XXXX Sounder Base for V Series Detectors 520Hz Sounder Base for V Series Detectors Sounder Base for PCOS Detectors 520Hz Sounder Base for PCOS Detectors WP Wall Mount Horn/Strobe WP Wall Mount Horn/Strobe Wall Mount Horn Wall Mount Strobe Wall Mount Horn/Strobe Ceiling Mount Strobe Ceiling Mount High Candela Strobe Ceiling Mount Horn/Strobe Ceiling Mount High Candela Horn/Strobe Wall Mount 520Hz Horn Wall Mount 520Hz Horn/Strobe Wall Mount Speaker/Strobe Ceiling Mount Speaker/Strobe Weatherproof Speaker/Strobe XXXX Magnetic Door Hold-Open Carbon Monoxide Detector )00)( )(XXX XXXX )(XX)( 28 92 52 92 180 90 22 85 102 127 135 245 160 246 285 309 94 140 273 325 333 551 111 152 281 333 324 554 166 219 266 381 437 78 101 188 245 94 140 273 325 551 159 15 75 Z N/A END OF CIRCUIT Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP10 Circuit: NAC1 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0.491 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 36 14 3.07 207 14 3.07 Low Frequency Device Device Address Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 10.1.1 P 15 0.078 36 20.291 0.109 0.0053 10.1.2 P 30 0.101 25 20.228 0.172 0.0084 10.1.3 P 15 0.078 30 20.171 0.229 0.0112 10.1.4 P 15 0.078 52 20.096 0.304 0.0149 10.1.5 P 15 0.078 50 20.048 0.352 0.0173 10.1.6 P 15 0.078 50 20.024 0.376 0.0184 END Z 0.000 0 20.024 0.376 0.0184 END Z 0.000 0 20.024 0.376 0.0184 END Z 0.000 0 20.024 0.376 0.0184 END Z 0.000 0 20.024 0.376 0.0184 END Z 0.000 0 20.024 0.376 0.0184 END Z 0.000 0 20.024 0.376 0.0184 END Z 0.000 0 20.024 0.376 0.0184 END Z 0.000 0 20.024 0.376 0.0184 END Z 0.000 0 20.024 0.376 0.0184 END Z 0.000 0 20.024 0.376 0.0184 END Z 0.000 0 20.024 0.376 0.0184 END Z 0.000 0 20.024 0.376 0.0184 END Z 0.000 0 20.024 0.376 0.0184 END Z 0.000 0 20.024 0.376 0.0184 END Z 0.000 0 20.024 0.376 0.0184 Totals: 0.491 243 CIRCUIT IS WITHIN LIMITS Percent Drop: 1.84% Current: 0.491 Point to Point Method Distance: End Line Voltage: 243 20.02 Voltage Drop: 0.38 of CIRCUIT IS WITHIN LIMITS Percent Drop: 1.80% Load Centering Method Current: 0.491 243 20.03 Distance: Voltage Drop: End of Line Voltage: 0.37 CIRCUIT IS WITHIN LIMITS Percent Drop: 3.59% Current: 0.491 End of Line Method Distance: End Line Voltage: 243 19.67 Volta 9 e Dro p:, 0.73 of Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP10 Circuit: NAC2 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.8 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000` 37 14 3.07 124 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 10.2.1 P 110 0.245 37 19.991 0.409 0.0200 10.2.2 P 110 0.245 9 19.905 0.495 0.0243 10.2.3 P 110 0.245 23 19.720 0.680 0.0333 10.2.4 P 110 0.245 20 19.589 0.811 0.0397 10.2.5 P 110 0.245 22 19.479 0.921 0.0452 10.2.6 P 110 0.245 23 19.397 1.003 0.0491 10.2.7 H 15 0.085 7 19.383 1.017 0.0498 10.2.8 P 110 0.245 20 19.353 1.047 0.0513 END Z 0.000 0 19.353 1.047 0.0513 END Z 0.000 0 19.353 1.047 0.0513 END Z 0.000 0 19.353 1.047 0.0513 END Z 0.000 0 19.353 1.047 0.0513 END Z 0.000 0 19.353 1.047 0.0513 END Z 0.000 0 19.353 1.047 0.0513 END Z 0.000 0 19.353 1.047 0.0513 END Z 0.000 0 19.353 1.047 0.0513 END Z 0.000 0 19.353 1.047 0.0513 END Z 0.000 0 19.353 1.047 0.0513 END Z 0.000 0 19.353 1.047 0.0513 END Z 0.000 0 19.353 1.047 0.0513 END Z 0.000 0 19.353 1.047 0.0513 T+140:Q42otais: 1.8 161 CIRCUIT IS WITHIN LIMITS Percent Drop: 5.13% Point to Point Method Current: 1.8 161 19.35 Distance: Voltage Drop: End of Line Voltage: 1.05 CIRCUIT IS WITHIN LIMITS Percent Drop: 4.36% Load Centering Method Current: 1.8 161 19.51 Distance: Voltage Drop: End of Line Voltage: 0.89 CIRCUIT IS WITHIN LIMITS Percent Drop: 8.72% Current: 1.8 End of Line Method 161 18.62 Distance: Voltage Drop: End of Line Voltage: 1.78 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP10 Circuit: NAC3 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.96 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Ohms / vuaae 1000' 32 14 3.07 106 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 10.3.1 P 110 0.245 32 20.015 0.385 0.0189 10.3.2 P 110 0.245 9 19.920 0.480 0.0235 10.3.3 P 110 0.245 20 19.740 0.660 0.0324 10.3.4 P 110 0.245 7 19.687 0.713 0.0350 10.3.5 P 110 0.245 9 19.633 0.767 0.0376 10.3.6 P 110 0.245 45 19.430 0.970 0.0476 10.3.7 P 110 0.245 9 19.403 0.997 0.0489 10.3.8 P 110 0.245 7 19.392 1.008 0.0494 END Z 0.000 0 19.392 1.008 0.0494 END Z 0.000 0 19.392 1.008 0.0494 END Z 0.000 0 19.392 1.008 0.0494 END Z 0.000 0 19.392 1.008 0.0494 END Z 0.000 0 19.392 1.008 0.0494 END Z 0.000 0 19.392 1.008 0.0494 END Z 0.000 0 19.392 1.008 . 0.0494 END Z 0.000 0 19.392 1.008 0.0494 END Z 0.000 0 19.392 1.008 0.0494 END Z 0.000 0 19.392 1.008 0.0494 END Z 0.000 0 19.392 1.008 0.0494 END Z 0.000 0 19.392 1.008 0.0494 END Z 0.000 0 19.392 1.008 0.0494 Totals: 1.96 138 CIRCUIT IS WITHIN LIMITS Percent Drop: 4.94% Current: 1.96 Point to Point Method Distance: End Line Voltage: 138 Voltage Drop: 1.01 of 19.39 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 4.07% Current: 1.96 138 19.57 Distance: Voltage Drop: End of Line Voltage: 0.83 CIRCUIT IS WITHIN LIMITS Percent Drop: 8.14% Current: 1.96 End of Line Method Distance: End Line Voltage: 138 Voltage Drop: 1.66 of 18.74 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP10 Circuit: NAC4 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.472 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guaae Ohms/ 1000' 28 14 3.07 296 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 10.4.1 D 0.092 28 20.147 0.253 0.0124 10.4.2 D 0.092 19 19.986 0.414 0.0203 10.4.3 D 0.092 15 19.867 0.533 0.0261 10.4.4 D 0.092 20 19.720 0.680 0.0333 10.4.5 D 0.092 26 19.544 0.856 0.0420 10.4.6 D 0.092 20 19.420 0.980 0.0480 10.4.7 D 0.092 21 19.301 1.099 0.0539 10.4.8 D 0.092 22 19.189 1.211 0.0593 10.4.9 D 0.092 19 19.104 1.296 0.0635 10.4.10 D 0.092 20 19.025 1.375 0.0674 10.4.11 D 0.092 19 18.960 1.440 0.0706 10.4.12 D 0.092 22 18.898 1.502 0.0736 10.4.13 D 0.092 21 18.851 1.549 0.0760 10.4.14 D 0.092 11 18.832 1.568 0.0769 10.4.15 D 0.092 22 18.807 1.593 0.0781 10.4.16 D 0.092 19 18.796 1.604 0.0786 END Z 0.000 0 18.796 1.604 0.0786 END Z 0.000 0 18.796 1.604 0.0786 END Z 0.000 0 18.796 1.604 0.0786 END Z 0.000 0 18.796 1.604 0.0786 END Z 0.000 0 18.796 1.604 0.0786 Totals: 1.472 324 CIRCUIT IS WITHIN LIMITS Point Point Method Percent Drop: 7.86% Current: 1.472 to Distance: 324 Voltage Drop: End of Line Voltage: 18.80 1.60 CIRCUIT IS WITHIN LIMITS Percent Drop: 7.18% Current: 1.472 Load Centering Method 324 18.94 Distance: Voltage Drop: End of Line Voltage: 1.46 CIRCUIT IS WITHIN LIMITS Percent Drop: 14.35% Current: 1.472 End of Line Method 324 17.47 Distance: Voltage Drop: End of Line Voltage: 2.93 Prosect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP1O Battery Calculations Standy Circuit / Device Current Alarm Current Qty Total Standy Current Total Alarm Current Power Supply 70 70 1 70 70 NAC Power NAC1 0 491 1 0 491 NAC2 0 1800 1 0 1800 NAC3 0 1960 1 0 1960 NAC4 96 1472 1 96 0 200 mA Aux Power Aux 0 0 0 0 0 Aux 0 0 0 0 0 Aux 0 0 0 0 0 TOTALS: 166 4321 Total Standy Current (Amps): 0.166 X 24 Hours: 3.984 Amphours in Standy Total Alarm Current (Amps): 4.321 X 15 Mins: 1.08 Amphours in Alarm 5.06 Required Amphours s' +20%Mar Totai Required Amphours: 5.06 5inafe`' 6.08 Am hours (2) 12V 8Ah Batteries Required. *Magnetic Door Holders are not included in the battery calculations. Power to these devices will be automatically disconnected upon loss of NC power to reduce battery size. DEVICE LEGEND Devices Current (Milliamps) Designator Part Number Description Light Ouput 0 15cd 30cd 75cd 95cd 110cd 177cd A B C D E F G H I J K L M N 0 P Q R S T U V W X Y SB4U SB4U-LF GSA-SBT SIGA-AB4G-LF INT-7ATW INT-8ATW EG1F-HD EG1F-VM EG1F-HDVM EGCF-VM EGCF-VMH EGCF-HDVM EGCF-HDVMH G4LFWF-H G4LFWF-HVM G4HFWF-S7VMC GCHFWF-S7VMC INT-4ASW XXXX DHF-24120C C01224T XXXX XXXX XXXX XXXX Sounder Base for V Series Detectors 520Hz Sounder Base for V Series Defectors Sounder Base for PCOS Detectors 520Hz Sounder Base for PCOS Detectors WP Wall Mount Horn/Strobe WP Wall Mount Horn/Strobe Wall Mount Horn Wall Mount Strobe Wall Mount Horn/Strobe Ceiling Mount Strobe Ceiling Mount High Candela Strobe Ceiling Mount Horn/Strobe Ceiling Mount High Candela Horn/Strobe Wall Mount 520Hz Horn Wall Mount 520Hz Horn/Strobe Wall Mount Speaker/Strobe Ceiling Mount Speaker/Strobe Weatherproof Speaker/Strobe XXXX Magnetic Door Hold-Open Carbon Monoxide Detector XXXX XXXX XXXX XXXX 28 92 52 92 180 90 22 85 127 245 285 309 102 135 160 246 94 140 273 325 333 551 111 152 281 333 324 554 166 219 266 381 437 78 101 188 245 94 140 273 325 551 159 15 75 Z N/A END OF CIRCUIT Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP11 Circuit: NAC1 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.31 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 56 14 I 3.07 101 14 I 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 11.1.1 P 110 0.245 56 19.950 0.450 0.0221 11.1.2 H 15 0.085 8 19.897 0.503 0.0246 11.1.3 P 110 0.245 29 19.723 0.677 0.0332 11.1.4 P 110 0.245 9 19.682 0.718 0.0352 11.1.5 P 110 0.245 29 19.595 0.805 0.0395 11.1.6 P 110 0.245 26 19.556 0.844 0.0414 END Z 0.000 0 19.556 0.844 0.0414 END Z 0.000 0 19.556 0.844 0.0414 END Z 0.000 0 19.556 0.844 0.0414 END Z 0.000 0 19.556 0.844 0.0414 END Z 0.000 0 19.556 0.844 0.0414 END Z 0.000 0 19.556 0.844 0.0414 END Z 0.000 0 19.556 0.844 0.0414 END Z 0.000 0 19.556 0.844 0.0414 END Z 0.000 0 19.556 0.844 0.0414 END Z 0.000 0 19.556 0.844 0.0414 END Z 0.000 0 19.556 0.844 0.0414 END Z 0.000 0 19.556 0.844 0.0414 END Z 0.000 0 19.556 0.844 0.0414 END Z 0.000 0 19.556 0.844 0.0414 END Z 0.000 0 19.556 0.844 0.0414 Totals: 1.31 157 CIRCUIT IS WITHIN LIMITS Current: 1.31 Percent Drop: 4.14% Point to Point Method End Line Distance: 157 Voltage Drop: 0.84 of Voltage: 19.56 CIRCUIT IS WITHIN LIMITS Percent Drop: 3.10% Current: 1.31 Load Centering Method Distance: 157 End of Line Voltage: 19.77 Voltage Drop: 0.63 CIRCUIT IS WITHIN LIMITS Percent Drop: 6.19% Current: 1.31 End of Line Method Distance: 157 End of Line Voltage: 19.14 Volta 9 e Dro 1.26 p: Proiect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP11 Circuit: NAC2 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0.491 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 26 14 3.07 229 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device '• Voltage Drop Voltage at Drop From Device Source Percent Drop 11.2.1 P 30 0.101 26 20.322 0.078 0.0038 11.2.2 P 15 0.078 15 20.286 0.114 0.0056 11.2.3 P 15 0.078 52 20.186 0.214 0.0105 11.2.4 P 15 0.078 55 20.107 0.293 0.0144 11.2.5 P 15 0.078 52 20.057 0.343 0.0168 11.2.6 P 15 0.078 55 20.031 0.369 0.0181 END Z 0.000 0 20.031 0.369 0.0181 END Z 0.000 0 20.031 0.369 0.0181 END Z 0.000 0 20.031 0.369 0.0181 END Z 0.000 0 20.031 0.369 0.0181 END Z 0.000 0 20.031 0.369 0.0181 END Z 0.000 0 20.031 0.369 0.0181 END Z 0.000 0 20.031 0.369 0.0181 END Z 0.000 0 20.031 0.369 0.0181 END Z 0.000 0 20.031 0.369 0.0181 END Z 0.000 0 20.031 0.369 0.0181 END Z 0.000 0 20.031 0.369 0.0181 END Z 0.000 0 20.031 0.369 0.0181 END Z 0.000 0 20.031 0.369 0.0181 END Z 0.000 0 20.031 0.369 0.0181 END Z 0.000 0 20.031 0.369 0.0181 T+140:Q42otals: 0.491 255 CIRCUIT IS WITHIN LIMITS Point to Point Method Percent Drop: 1.81 % Current: 0.491 255 20.03 Distance: Voltage Drop: End of Line Voltage: 0.37 CIRCUIT IS WITHIN LIMITS Percent Drop: 1.88% Load Centering Method Current: 0.491 255 20.02 Distance: Voltage Drop: End of Line Voltage: 0.38 CIRCUIT IS WITHIN LIMITS Percent Drop: 3.77% Current: 0.491 End of Line Method 255 19.63 Distance: Voltage Drop: End of Line Voltage: 0.77 Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP11 Circuit: NAC3 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guaae Ohms/ 1000' 0 14 3.07 0 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 Totals: 0 0 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 Point to Point Method 0 20.40 Distance: Voltage Drop: End of Line Voltage: 0.00 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 0 20.40 Distance: Voltage Drop: End of Line Voltage: 0.00 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 End of Line Method 0 , 20.40 Distance: Voltage Drop: End of Line Voltage: 0.00 Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP11 Circuit: NAC4 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.472 Distance to 1st Device: Remaining Distance: Amps System Type: Wire Guage Ohms/ 1000' 37 14 3.07 307 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 11.4.1 D 0.092 37 20.066 0.334 0.0164 11.4.2 D 0.092 23 19.871 0.529 0.0259 11.4.3 D 0.092 27 19.657 0.743 0.0364 11.4.4 D 0.092 13 19.562 0.838 0.0411 11.4.5 D 0.092 22 19.413 0.987 0.0484 11.4.6 D 0.092 20 19.288 1.112 0.0545 11.4.7 D 0.092 18 19.187 1.213 0.0595 11.4.8 D 0.092 22 19.075 1.325 0.0650 11.4.9 D 0.092 19 18.989 1.411 0.0692 11.4.10 D 0.092 22 18.902 1.498 0.0734 11.4.11 D 0.092 25 18.817 1.583 0.0776 11.4.12 D 0.092 22 18.755 1.645 0.0806 11.4.13 D 0.092 22 18.705 1.695 0.0831 11.4.14 D 0.092 19 18.673 1.727 0.0846 11.4.15 D 0.092 19 18.652 1.748 0.0857 11.4.16 D 0.092 14 18.644 1.756 0.0861 END Z 0.000 0 18.644 1.756 0.0861 END Z 0.000 0 18.644 1.756 0.0861 END Z 0.000 0 18.644 1.756 0.0861 END Z 0.000 0 18.644 1.756 0.0861 END Z 0.000 0 18.644 1.756 0.0861 Totals: 1.472 344 CIRCUIT IS WITHIN LIMITS Point to Point Method Percent Drop: 8.61% Current: 1.472 Distance: 344 Voltage Drop: End of Line Voltage: 18.64 1.76 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 7.62% Current: 1.472 Distance: 344 Voltage Drop: End of Line Voltage: 18.85 1.55 End Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 15.24% Current: 1.472 of Distance: 344 Voltage Drop: End of Line Voltage: 17.29 3.11 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP11 Battery Calculations Standy Circuit / Device Current Alarm Current Qty Total Standy Current Total Alarm Current Power Supply 70 70 1 70 70 NAC Power NAC1 0 1310 1 0 1310 NAC2 0 491 1 0 491 NAC3 0 0 0 0 0 NAC4 96 1472 1 96 0 200 mA Aux Power Aux 0 0 0 0 0 Aux 0 0 0 0 0 Aux 0 0 0 0 0 TOTALS: 166 1871 Total Standy Current (Amps): 0.166 X 24 Hours: 3.984 Amphours in Standy Total Alarm Current (Amps): 1.871 X 15 Mins: 0.47 Amphours in Alarm 4.45 Required Amphours Required Amphours: 4.45 +20% afety 5.34 MarginAmphours (2) 12V 8Ah Batteries Required. `Magnetic Door Holders are not included in the battery calculations. Power to these devices will be automatically disconnected upon loss of NC power to reduce battery size. DEVICE LEGEND Devices Current (Milliamps) Designator Part Number Description Light Ouput 0 15cd 30cd 75cd 95cd 110cd 177cd <O000 W lio2—'-Y_12ZOdoW ctl-D> X>- SB4U SB4U-LF GSA-SBT SIGA-AB4G-LF INT-7ATW INT-8ATW EG1 F-HD EG1F-VM EG1F-HDVM EGCF-VM EGCF-VMH EGCF-HDVM EGCF-HDVMH G4LFWF-H G4LFWF-HVM G4HFWF-S7VMC GCHFWF-S7VMC INT-4ASW XXXX DHF-24120C C01224T XXXX XXXX XXXX XXXX Sounder Base for V Series Detectors 520Hz Sounder Base for V Series Detectorsi Sounder Base for PCOS Detectors 520Hz Sounder Base for PCOS Detectors WP Wall Mount Horn/Strobe WP Wall Mount Horn/Strobe Wall Mount Horn Wall Mount Strobe Wall Mount Horn/Strobe Ceiling Mount Strobe Ceiling Mount High Candela Strobe Ceiling Mount Horn/Strobe Ceiling Mount High Candela Horn/Strobe Wall Mount 520Hz Horn Wall Mount 520Hz Horn/Strobe Wall Mount Speaker/Strobe Ceiling Mount Speaker/Strobe Weatherproof Speaker/Strobe XXXX Magnetic Door Hold-Open Carbon Monoxide Detector XXXX XXXX XXXX XXXX 28 92 52 92 180 90 22 85 102 127 135 245 160 246 285 309 94 140 273 325 333 551 111 152 281 333 324 554 166 219 266 381 437 78 101 188 245 94 140 273 325 551 159 15 75 Z N/A END OF CIRCUIT Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP12 Circuit: NAC1 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.225 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaoe Ohms/ 1000' 148 14 3.07 80 14 3.07 Low Frequency Device Device Address Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 12.1.1 P 110 0.245 148 19.287 1.113 0.0546 12.1.2 P 110 0.245 22 19.154 1.246 0.0611 12.1.3 P 110 0.245 19 19.069 1.331 0.0653 12.1.4 P 110 0.245 19 19.012 1.388 0.0681 12.1.5 P 110 0.245 20 18.981 1.419 0.0695 END Z 0.000 0 18.981 1.419 0.0695 END Z 0.000 0 18.981 1.419 0.0695 END Z 0.000 0 18.981 1.419 0.0695 END Z 0.000 0 18.981 1.419 0.0695 END Z 0.000 0 18.981 1.419 0.0695 END Z 0.000 0 18.981 1.419 0.0695 END Z 0.000 0 18.981 1.419 0.0695 END Z 0.000 0 18.981 1.419 0.0695 END Z 0.000 0 18.981 1.419 0.0695 END Z 0.000 0 18.981 1.419 0.0695 END Z 0.000 0 18.981 1.419 0.0695 END Z 0.000 0 18.981 1.419 0.0695 END Z 0.000 0 18.981 1.419 0.0695 END Z 0.000 0 18.981 1.419 0.0695 END Z 0.000 0 18.981 1.419 0.0695 END Z 0.000 0 18.981 1.419 0.0695 Totals: 1.225 228 CIRCUIT IS WITHIN LIMITS Percent Drop: 6.95% Current: 1.225 Point to Point Method Distance: End Line Voltage: 228 Voltage Drop: 1.42 of 18.98 CIRCUIT IS WITHIN LIMITS Percent Drop: 4.20% Current: 1.225 Load Centering Method Distance: End 228 Voltage Drop: 0.86 of Line Voltage: 19.54 CIRCUIT IS WITHIN LIMITS Percent Drop: 8.41% Current:' 1.225 End of Line Method Distance: End Line Voltage: 228 18.69 Voltage Drop: 1.71 of Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP12 Circuit: NAC2 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.225 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 69 14 3.07 93 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 12.2.1 P 110 0.245 69 19.881 0.519 0.0254 12.2.2 P 110 0.245 23 19.743 0.657 0.0322 12.2.3 P 110 0.245 9 19.702 0.698 0.0342 12.2.4 P 110 0.245 38 19.588 0.812 0.0398 12.2.5 P 110 0.245 23 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 Totals: 1.225 162 CIRCUIT IS WITHIN LIMITS Percent Drop: 4.15% Current: 1.225 Point to Point Method 162 19.55 Distance: Voltage Drop: End of Line Voltage: _ _ 0.85 CIRCUIT IS WITHIN LIMITS Percent Drop: 2.99% Load Centering Method Current: 1.225 162 19.79 Distance: Voltage Drop: End of Line Voltage: 0.61 CIRCUIT IS WITHIN LIMITS Percent Drop: 5.97% End of Line Method Current: 1.225 162 19.18 Distance: Voltage Drop: End of Line Voltage: 1.22 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP12 Circuit: NAC3 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 2.13 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 44 14 3.07 138 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 12.3.1 P 110 0.245 44 19.825 0.575 0.0282 12.3.2 P 110 0.245 9 19.720 0.680 0.0333 12.3.3 P 110 0.245 19 19.529 0.871 0.0427 12.3.4 P 110 0.245 6 19.478 0.922 0.0452 12.3.5 P 110 0.245 9 19.414 0.986 0.0483 12.3.6 P 110 0.245 42 19.181 1.219 0.0598 12.3.7 P 110 0.245 11 19.136 1.264 0.0620 12.3.8 H 15 0.085 10 19.111 1.289 0.0632 12.3.9 P 110 0.245 25 19.060 1.340 0.0657 12.3.10 H 15 0.085 7 19.056 1.344 0.0659 END Z 0.000 0 19.056 1.344 0.0659 END Z 0.000 0 19.056 1.344 0.0659 END Z 0.000 0 19.056 1.344 0.0659 END Z 0.000 0 19.056 1.344 0.0659 END Z 0.000 0 19.056 1.344 0.0659 END Z 0.000 0 19.056 1.344 0.0659 END Z 0.000 0 19.056 1.344 0.0659 END Z 0.000 0 19.056 1.344 0.0659 END Z 0.000 0 19.056 1.344 0.0659 END Z 0.000 0 19.056 1.344 0.0659 END Z 0.000 0 19.056 1.344 0.0659 Totals: 2.13 182 CIRCUIT IS WITHIN LIMITS Percent Drop: 6.59% Current: 2.13 Point to Point Method Distance: End Line Voltage: 182 Voltage Drop: 1.34 of 19.06 CIRCUIT IS WITHIN LIMITS Percent Drop: 5.83% Current: 2.13 Load Centering Method Distance: End Line Voltage: 182 19.21 Voltage Drop: 1.19 of CIRCUIT IS WITHIN LIMITS Percent Drop: 11.67% Current: 2.13 End of Line Method Distance: End Line Voltage: 182 18.02 Voltage Drop: 2.38 of Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP12 Circuit: NAC4 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.472 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 39 14 3.07 295 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 12.4.1 D 0.092 39 20.048 0.352 0.0173 12.4.2 D 0.092 20 19.878 0.522 0.0256 12.4.3 D 0.092 16 19.752 0.648 0.0318 12.4.4 D 0.092 20 19.605 0.795 0.0390 12.4.5 D 0.092 25 19.435 0.965 0.0473 12.4.6 D 0.092 19 19.317 1.083 0.0531 12.4.7 D 0.092 22 19.193 1.207 0,0592 12.4.8 D 0.092 20 19.091 1.309 0.0642 12.4.9 D 0.092 22 18.992 1.408 0.0690 12.4.10 D 0.092 18 18.921 1.479 0.0725 12.4.11 D 0.092 21 18.849 1.551 0.0760 12.4.12 D 0.092 19 18.796 1.604 0.0786 12.4.13 D 0.092 21 18.748 1.652 0.0810 12.4.14 D 0.092 11 18.730 1.670 0.0819 12.4.15 D 0.092 22 18.705 1.695 0.0831 12.4.16 D 0.092 19 18.694 1.706 0.0836 END Z 0.000 0 18.694 1.706 0.0836 END Z 0.000 0 18.694 1.706 0.0836 END Z 0.000 0 18.694 1.706 0.0836 END Z 0.000 0 18.694 1.706 0.0836 END Z 0.000 0 18.694 1.706 0.0836 Totals: 1.472 334 CIRCUIT IS WITHIN LIMITS Percent Drop: 8.36% Current: 1.472 Point to Point Method 334 18.69 Distance: End of Line Voltage: 1.71 Voltage Drop: CIRCUIT IS WITHIN LIMITS Percent Drop: 7.40% Current: 1.472 Load Centering Method 334 18.89 Distance: End of Line Voltage: 1.51 Voltage Drop: CIRCUIT IS WITHIN LIMITS Percent Drop: 14.80% Current: 1.472 End of Line Method 334 17.38 Distance: Voltage Drop: End of Line Voltage: 3.02 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP12 Battery Calculations Standy Circuit / Device Current Alarm Current Qty Total Standy Current Total Alarm Current Power Supply 70 70 1 70 70 NAC Power NAC1 0 1225 1 0 1225 NAC2 0 1225 1 0 1225 NAC3 0 2130 1 0 2130 NAC4 96 1472 1 96 0 200 mA Aux Power Aux 0 0 0 0 0 Aux 0 0 0 0 0 Aux 0 0 0 0 0 TOTALS: 166 4650 Total Standy Current (Amps): 0.166 X 24 Hours: 3.984 Amphours in Standy Total Alarm Current (Amps): 4.65 X 15 Mins: 1.16 Amphours in Alarm 5.15 Required Amphours Required Amphours: 5.15 +20% Safety 6.18 Margin Total Amphours (2) 12V 8Ah Batteries Required. *Magnetic Door Holders are not included in the battery calculations. Power to these devices will be automatically disconnected upon loss of A/C power to reduce battery size. DEVICE LEGEND Devices Current (Milliamps) Designator Part Number Description Light Ouput 0 15cd 30cd 75cd 95cd 110cd 177cd A B C D E F G H I J K L M N 0 P Q R S T U V W X Y SB4U SB4U-LF GSA-SBT SIGA-AB4G-LF INT-7ATW INT-8ATW EG1F-HD EG1F-VM EG1F-HDVM EGCF-VM EGCF-VMH EGCF-HDVM EGCF-HDVMH G4LFWF-H G4LFWF-HVM G4HFWF-S7VMC GCHFWF-S7VMC INT-4ASW XXXX DHF -24120C CO1224T XXXX XXXX )(XXX XXXX Sounder Base for V Series Detectors 520Hz Sounder Base for V Series Detectors Sounder Base for PCOS Detectors 520Hz Sounder Base for PCOS Detectors WP Wall Mount Horn/Strobe WP Wall Mount Horn/Strobe Wall Mount Horn Wall Mount Strobe Wall Mount Horn/Strobe Ceiling Mount Strobe Ceiling Mount High Candela Strobe Ceiling Mount Horn/Strobe Ceiling Mount High Candela Horn/Strobe Wall Mount 520Hz Horn Wall Mount 520Hz Horn/Strobe Wall Mount Speaker/Strobe Ceiling Mount Speaker/Strobe Weatherproof Speaker/Strobe XXXX Magnetic Door Hold -Open Carbon Monoxide Detector XXXX XXXX XXXX XXXX 28 92 52 92 180 90 22 85 127 245 285 102 135 160 246 309 94 140 273 325 333 551 111 152 281 333 324 554 166 219 266 381 437 78 101 188 245 94 140 273 325 551 159 15 75 Z N/A END OF CIRCUIT PrOiect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP13 Circuit: NAC1 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0.569 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Ouaae Ohms/ 1000' 27 14 3.07 218 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 13.1.1 P 15 0.078 27 20.306 0.094 0.0046 13.1.2 P 15 0.078 7 20.285 0.115 0.0057 13.1.3 P 30 0.101 29 20.211 0.189 0.0093 13.1.4 P 15 0.078 30 20.154 0.246 0.0121 13.1.5 P 15 0.078 52 20.079 0.321 0.0157 13.1.6 P 15 0.078 50 20.031 0.369 0.0181 13.1.7 P 15 0.078 50 20.007 0.393 0.0193 END Z 0.000 0 20.007 0.393 0.0193 END Z 0.000 0 20.007 0.393 0.0193 END Z 0.000 0 20.007 0.393 0.0193 END Z 0.000 0 20.007 0.393 0.0193 END Z 0.000 0 20.007 0.393 0.0193 END Z 0.000 0 20.007 0.393 0.0193 END Z 0.000 0 20.007 0.393 0.0193 END Z 0.000 0 20.007 0.393 0.0193 END Z 0.000 0 20.007 0.393 0.0193 END Z 0.000 0 20.007 0.393 0.0193 END Z 0.000 0 20.007 0.393 0.0193 END Z 0.000 0 20.007 0.393 0.0193 END Z 0.000 0 20.007 0.393 0.0193 END Z 0.000 0 20.007 0.393 0.0193 Totals: 0.569 245 CIRCUIT IS WITHIN LIMITS Percent Drop: 1.93% Current: 0.569 Point to Point Method End Line Voltage: Distance: 245 20.01 Volta 9 a Dro 0.39 p:, of Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 2.10% Current:! 0.569 Distance:' 245 19.97 End of Line Voltage: Voltage Drop:• 0.43 CIRCUIT IS WITHIN LIMITS Percent Drop: 4.20% Current: 0.569 End of Line Method Distance: 245 19.54 End Line Voltage: Voltage Drop: 0.86 of Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP13 Circuit: NAC2 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.715 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms / 1000' 35 14 3.07 114 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 13.2.1 P 110 0.245 35 20.031 0.369 0.0181 13.2.2 P 110 0.245 9 19.950 0.450 0.0220 13.2.3 P 110 0.245 22 19.785 0.615 0.0302 13.2.4 P 110 0.245 19 19.670 0.730 0.0358 13.2.5 P 110 0.245 22 19.571 0.829 0.0406 13.2.6 P 110 0.245 20 19.511 0.889 0.0436 13.2.7 P 110 0.245 22 19.478 0.922 0.0452 END Z 0.000 0 19.478 0.922 0.0452 END Z 0.000 0 19.478 0.922 0.0452 END Z 0.000 0 19.478 0.922 0.0452 END Z 0.000 0 19.478 0.922 0.0452 END Z 0.000 0 19.478 0.922 0.0452 END Z 0.000 0 19.478 0.922 0.0452 END Z 0.000 0 19.478 0.922 0.0452 END Z 0.000 0 19.478 0.922 0.0452 END Z 0.000 0 19.478 0.922 0.0452 END Z 0.000 0 19.478 0.922 0.0452 END Z 0.000 0 19.478 0.922 0.0452 END Z 0.000 0 19.478 0.922 0.0452 END Z 0.000 0 19.478 0.922 0.0452 END Z 0.000 0 19.478 0.922 0.0452 Totals: 1.715 149 CIRCUIT IS WITHIN LIMITS Point to Point Method Percent Drop: 4.52% Current: 1.715 149 19.48 Distance: Voltage Drop: End of Line Voltage: 0.92 CIRCUIT IS WITHIN LIMITS Percent Drop: 3.85% Load Centering Method Current: 1.715 149 19.62 Distance: Voltage Drop: End of Line Voltage: 0.78 CIRCUIT IS WITHIN LIMITS End of Line Method Percent Drop: 7.69% Current: 1.715 149 18.83 Distance: Voltage Drop: End of Line Voltage: 1.57 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP13 Circuit: NAC3 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.8 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaoe Ohms/ 1000' 152 14 3.07 104 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 13.3.1 P 110 0.245 152 18.720 1.680 0.0823 13.3.2 P 110 0.245 21 18.520 1.880 0.0922 13.3.3 P 110 0.245 16 18.391 2.009 0.0985 13.3.4 P 110 0.245 9 18.332 2.068 0.1014 13.3.5 H 15 0.085 7 18.297 2.103 0.1031 13.3.6 P 110 0.245 35 18.139 2.261 0.1108 13.3.7 P 110 0.245 9 18.112 2.288 0.1122 13.3.8 P 110 0.245 7 18.101 2.299 0.1127 END Z 0.000 0 18.101 2.299 0.1127 END Z 0.000 0 18.101 2.299 0.1127 END Z 0.000 0 18.101 2.299 0.1127 END Z 0.000 0 18.101 2.299 0.1127 END Z 0.000 0 18.101 2.299 0.1127 END Z 0.000 0 18.101 2.299 0.1127 END Z 0.000 0 18.101 2.299 0.1127 END Z 0.000 0 18.101 2.299 0.1127 END Z 0.000 0 18.101 2.299 0.1127 END Z 0.000 0 18.101 2.299 0.1127 END Z 0.000 0 18.101 2.299 0.1127 END Z 0.000 0 18.101 2.299 0.1127 END Z 0.000 0 18.101 2.299 0.1127 Totals: 1.8 256 CIRCUIT IS WITHIN LIMITS Percent Drop: 11.27% Current: 1.8 Point to Point Method Distance: 256 Voltage Drop: End of Line Voltage: 18.10 2.30 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 6.93% Current: 1.8 256 18.99 Distance: Voltage Drop: End of Line Voltage: 1.41 CIRCUIT IS WITHIN LIMITS Percent Drop: 13.87% Current: 1.8 End of Line Method Distance: End Line Voltage: 256 17.57 Voltage Drop: 2.83 of Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP13 Circuit: NAC4 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.012 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Ouaae Ohms/ 1000' 48 14 3.07 207 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 13.4.1 D 0.092 48 20.102 0.298 0.0146 13.4.2 D 0.092 19 19.994 0.406 0.0199 13.4.3 D 0.092 22 19.883 0.517 0.0254 13.4.4 D 0.092 19 19.797 0.603 0.0296 13.4.5 D 0.092 23 19.706 0.694 0.0340 13.4.6 D 0.092 19 19.641 0.759 0.0372 13.4.7 D 0.092 18 19.591 0.809 0.0397 13.4.8 D 0.092 22 19.541 0.859 0.0421 13.4.9 D 0.092 20 19.507 0.893 0.0438 13.4.10 D 0.092 26 19.478 0.922 0.0452 13.4.11 D 0.092 19 19.467 0.933 0.0457 END Z 0.000 0 19.467 0.933 0.0457 END Z 0.000 0 19.467 0.933 0.0457 END Z 0.000 0 19.467 0.933 0.0457 END Z 0.000 0 19.467 0.933 0.0457 END Z 0.000 0 19.467 0.933 0.0457 END Z 0.000 0 19.467 0.933 0.0457 END Z 0.000 0 19.467 0.933 0.0457 END Z 0.000 0 19.467 0.933 0.0457 END Z 0.000 0 19.467 0.933 0.0457 END Z 0.000 0 19.467 0.933 0.0457 Totals: 1.012 255 CIRCUIT IS WITHIN LIMITS Percent Drop: 4.57% Current: 1.012 Point to Point Method 255 19.47 Distance: End of Line Voltage: 0.93 Voltage Drop: CIRCUIT IS WITHIN LIMITS Percent Drop: 3.88% Current: 1.012 Load Centering Method 255 19.61 Distance: End of Line Voltage: 0.79 Voltage Drop: CIRCUIT IS WITHIN LIMITS Percent Drop: 7.77% Current: 1.012 End of Line Method 255 18.82 Distance: Voltage Drop: End of Line Voltage: 1.58 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP13 Battery Calculations Standy Circuit / Device Current Alarm Current Qty Total Standy Current Total Alarm Current Power Supply 70 70 1 70 70 NAC Power NAC1 0 569 1 0 569 NAC2 0 1715 1 0 1715 NAC3 0 1800 1 0 1800 NAC4 66 1012 1 66 0 200 mA Aux Power Aux 0 0 0 0 0 Aux 0 0 0 0 0 Aux 0 0 0 0 0 TOTALS: 136 4154 Total Standy Current (Amps): 0.136 X 24 Hours: 3.264 Amphours in Standy Total Alarm Current (Amps): 4.154 X 15 Mins: 1.04 Amphours in Alarm 4.30 Required Amphours Required Amphours: +20% Safety 4.30 516. Total Margin Am hours P (2) 12V 8Ah Batteries Required. *Magnetic Door Holders are not included in the battery calculations. Power to these devices will be automatically disconnected upon loss of NC power to reduce battery size. DEVICE LEGEND Devices Current (Milliamps) Designator Part Number Description Light Ouput 0 15cd 30cd 75cd 95cd 110cd 177cd A B C D E F G H I J K L M N 0 P Q R S T U V W X Y SB4U SB4U-LF GSA-SBT SIGA-AB4G-LF INT-7ATW INT-8ATW EG1F-HD EG1F-VM EG1F-HDVM EGCF-VM EGCF-VMH EGCF-HDVM EGCF-HDVMH G4LFWF-H G4LFWF-HVM G4HFWF-S7VMC GCHFWF-S7VMC INT-4ASW XXXX DHF-24120C C01224T XXXX XXXX XXXX XXXX Sounder Base for V Series Detectors 520Hz Sounder Base for V Series Detectors Sounder Base for PCOS Detectors 520Hz Sounder Base for PCOS Detectors WP Wall Mount Horn/Strobe WP Wall Mount Horn/Strobe Wall Mount Horn Wall Mount Strobe Wall Mount Horn/Strobe Ceiling Mount Strobe Ceiling Mount High Candela Strobe Ceiling Mount Horn/Strobe Ceiling Mount High Candela Horn/Strobe Wall Mount 520Hz Horn Wall Mount 520Hz Horn/Strobe Wall Mount Speaker/Strobe Ceiling Mount Speaker/Strobe Weatherproof Speaker/Strobe XXXX Magnetic Door Hold-Open Carbon Monoxide Detector XXXX XXXX XXXX XXXX 28 92 52 92 180 90 22 85 127 245 285 102 135 160 246 309 94 140 273 325 333 551 111 152 281 333 324 554 166 219 266 381 437 78 101 188 245 94 140 273 325 551 159 15 75 Z N/A END OF CIRCUIT Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP14 Circuit: NAC1 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.47 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Ouaae Ohms/ 1000' 37 14 3.07 103 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 14.1.1 P 110 0.245 37 20.066 0.334 0.0164 14.1.2 P 110 0.245 19 19.923 0.477 0.0234 14.1.3 P 110 0.245 22 19.791 0.609 0.0299 14.1.4 P 110 0.245 19 19.705 0.695 0.0341 14.1.5 P 110 0.245 23 19.636 0.764 0.0375 14.1.6 P 110 0.245 20 19.606 0.794 0.0389 END Z 0.000 0 19.606 0.794 0.0389 END Z 0.000 0 19.606 0.794 0.0389 END Z 0.000 0 19.606 0.794 0.0389 END Z 0.000 0 19.606 0.794 0.0389 END Z 0.000 0 19.606 0.794 0.0389 END Z 0.000 0 19.606 0.794 0.0389 END Z 0.000 0 19.606 0.794 0.0389 END Z 0.000 0 19.606 0.794 0.0389 END Z 0.000 0 19.606 0.794 0.0389 END Z 0.000 0 19.606 0.794 0.0389 END Z 0.000 0 19.606 0.794 0.0389 END Z 0.000 0 19.606 0.794 0.0389 END Z 0.000 0 19.606 0.794 0.0389 END Z 0.000 0 19.606 0.794 0.0389 END Z 0.000 0 19.606 0.794 0.0389 Totals: 1.47 140 CIRCUIT IS WITHIN LIMITS Point to Point Method Percent Drop: 3.89% Current: 1.47 140 Distance:. End Line Voltage Drop:; 0.79 of Voltage: 19.61 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 3.10% Current: 1.47 140 19.77 Distance: Voltage Drop: End of Line Voltage: 0.63 CIRCUIT IS WITHIN LIMITS Percent Drop: 6.19% Current: 1.47 End of Line Method Distance: End Line Voltage: 140 Volta 9 e Dro p:; 1.26 of 19.14 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP14 Circuit: NAC2 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.225 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 152 14 3.07 76 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 14.2.1 P 110 0.245 152 19.257 1.143 0.0560 14.2.2 P 110 0.245 18 19.148 1.252 0.0614 14.2.3 P 110 0.245 9 19.108 1.292 0.0633 14.2.4 P 110 0.245 40 18.987 1.413 0.0692 14.2.5 P 110 0.245 9 18.974 1.426 0.0699 END Z 0.000 0 18.974 1.426 0.0699 END Z 0.000 0 18.974 1.426 0.0699 END Z 0.000 0 18.974 1.426 0.0699 END Z 0.000 0 18.974 1.426 0.0699 END Z 0.000 0 18.974 1.426 0.0699 END Z 0.000 0 18.974 1.426 0.0699 END Z 0.000 0 18.974 1.426 0.0699 END Z 0.000 0 18.974 1.426 0.0699 END Z 0.000 0 18.974 1.426 0.0699 END Z 0.000 0 18.974 1.426 0.0699 END Z 0.000 0 18.974 1.426 0.0699 END Z 0.000 0 18.974 1.426 0.0699 END Z 0.000 0 18.974 1.426 0.0699 END Z 0.000 0 18.974 1.426 0.0699 END Z 0.000 0 18.974 1.426 0.0699 END Z 0.000 0 18.974 1.426 0.0699 Totals: 1.225 228 CIRCUIT IS WITHIN LIMITS Point to Point Method Percent Drop: 6.99% Current: 1.225 228 18.97 Distance: End of Line Voltage: 1.43 Voltage Drop: CIRCUIT IS WITHIN LIMITS Percent Drop: 4.20% Load Centering Method Current: 1.225 228 19.54 Distance: End of Line Voltage: 0.86 Voltage Drop: CIRCUIT IS WITHIN LIMITS Percent Drop: 8.41% Current: 1.225 End of Line Method 228 18.69 Distance: Voltage Drop: End of Line Voltage: 1.71 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP14 Circuit: NAC3 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.47 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 101 14 3.07 119 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 14.3.1 P 110 0.245 101 19.488 0.912 0.0447 14.3.2 P 110 0.245 29 19.270 1.130 0.0554 14.3.3 P 110 0.245 17 19.168 1.232 0.0604 14.3.4 P 110 0.245 34 19.015 1.385 0.0679 14.3.5 P 110 0.245 16 18.966 1.434 0.0703 14.3.6 P 110 0.245 23 18.932 1.468 0.0720 END Z 0.000 0 18.932 1.468 0.0720 END Z 0.000 0 18.932 1.468 0.0720 END Z 0.000 0 18.932 1.468 0.0720 END Z 0.000 0 18.932 1.468 0.0720 END Z 0.000 0 18.932 1.468 0.0720 END Z 0.000 0 18.932 1.468 0.0720 END Z 0.000 0 18.932 1.468 0.0720 END Z 0.000 0 18.932 1.468 0.0720 END Z 0.000 0 18.932 1.468 0.0720 END Z 0.000 0 18.932 1.468 0.0720 END Z 0.000 0 18.932 1.468 0.0720 END Z 0.000 0 18.932 1.468 0.0720 END Z 0.000 0 18.932 1.468 0.0720 END Z 0.000 0 18.932 1.468 0.0720 END Z 0.000 0 18.932 1.468 0.0720 Totals: 1.47 220 CIRCUIT IS WITHIN LIMITS Percent Drop: 7.20% Current: 1.47 Point to Point Method Distance: 220 Voltage Drop: End of Line Voltage: 18.93 1.47 CIRCUIT IS WITHIN LIMITS Percent Drop: 4.87% Load Centering Method Current: 1.47 Distance: Voltage Drop: 220 End of Line Voltage: 19.41 0.99 CIRCUIT IS WITHIN LIMITS Percent Drop: 9.73% Current: 1.47 End of Line Method Distance: End Line Voltage: 220 Voltage Drop: 1.99 of 18.41 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP14 Circuit: NAC4 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.472 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guage Ohms/ 1000' 49 14 3.07 303 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 14.4.1 D 0.092 49 19.957 0.443 0.0217 14.4.2 D 0.092 19 19.796 0.604 0.0296 14.4.3 D 0.092 25 19.598 0.802 0.0393 14.4.4 D 0.092 14 19.496 0.904 0.0443 14.4.5 D 0.092 18 19.374 1.026 0.0503 14.4.6 D 0.092 16 19.274 1.126 0.0552 14.4.7 D 0.092 19 19.167 1.233 0.0604 14.4.8 D 0.092 28 19.025 1.375 0.0674 14.4.9 D 0.092 17 18.948 1.452 0.0712 14.4.10 D 0.092 20 18.869 1.531 0.0751 14.4.11 D 0.092 23 18.791 1.609 0.0789 14.4.12 D 0.092 22 18.729 1.671 0.0819 14.4.13 D 0.092 23 18.677 1.723 0.0845 14.4.14 D 0.092 19 18.644 1.756 0.0861 14.4.15 D 0.092 19 18.623 1.777 0.0871 14.4.16 D 0.092 21 18.611 1.789 0.0877 END Z 0.000 0 18.611 1.789 0.0877 END Z 0.000 0 18.611 1.789 0.0877 END Z 0.000 0 18.611 1.789 0.0877 END Z 0.000 0 18.611 1.789 0.0877 END Z 0.000 0 18.611 1.789 0.0877 Totals: 1.472 352 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 8.77% Current: 1.472 Distance: 352 Voltage Drop: End of Line Voltage: 18.61 1.79 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 7.80% Current: 1.472 Distance: 352 Voltage Drop: End of Line Voltage: 18.81 1.59 End Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 15.60% Current: 1.472 of Distance: 352 Voltage Drop: End of Line Voltage: 17.22 3.18 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP14 Battery Calculations Standy Circuit / Device Current Alarm Current Qty Total Standy Current Total Alarm Current Power Supply 70 70 1 70 70 NAC Power NAC1 0 1470 1 0 1470 NAC2 0 1225 1 0 1225 NAC3 0 1470 1 0 1470 NAC4 96 1472 1 96 0 200 mA Aux Power Aux 0 0 0 0 0 Aux 0 0 0 0 0 Aux 0 0 0 0 0 TOTALS: 166 4235 Total Standy Current (Amps): 0.166 X 24 Hours: 3.984 Amphours in Standy Total Alarm Current (Amps): 4.235 X 15 Mins: 1.06 Amphours in Alarm 5.04 Required Amphours +20% Safetyr Tota! Required Amphours: 5.04 Margin 6.05 hours Amphours (2) 12V 8Ah Batteries Required. `Magnetic Door Holders are not included in the battery calculations. Power to these devices will be automatically disconnected upon Toss of NC power to reduce battery size. DEVICE LEGEND Devices Current (Milliamps) Designator Part Number Description LightOuput 0 15cd 30cd 75cd 95cd 110cd 177cd A B C D E F G H I J K L M N O P Q R S T U V W X Y SB4U SB4U-LF GSA-SBT SIGA-AB4G-LF INT-7ATW INT-8ATW EG1F-HD EG1 F-VM EG1F-HDVM EGCF-VM EGCF-VMH EGCF-HDVM EGCF-HDVMH G4LFWF-H G4LFWF-HVM G4HFWF-S7VMC GCHFWF-S7VMC INT-4ASW XXXX DHF-24120C C01224T XXXX XXXX XXXX XXXX Sounder Base for V Series Detectors 520Hz Sounder Base for V Series Detectors Sounder Base for PCOS Detectors 520Hz Sounder Base for PCOS Detectors WP Wall Mount Horn/Strobe WP Wall Mount Horn/Strobe Wall Mount Horn Wall Mount Strobe Wall Mount Horn/Strobe Ceiling Mount Strobe Ceiling Mount High Candela Strobe Ceiling Mount Horn/Strobe Ceiling Mount High Candela Horn/Strobe Wall Mount 520Hz Horn Wall Mount 520Hz Horn/Strobe Wall Mount Speaker/Strobe Ceiling Mount Speaker/Strobe Weatherproof Speaker/Strobe XXXX Magnetic Door Hold-Open Carbon Monoxide Detector XXXX XXXX XXXX XXXX 28 92 52 92 180 90 22 85 102 127 135 245 160 246 285 309 94 140 273 325 333 551 111 152 281 333 324 554 166 219 266 381 437 78 101 188 245 94 140 273 325 551 159 15 75 Z N/A END OF CIRCUIT Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP15 Circuit: NAC1 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.225 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 11 14 3.07 93 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 15.1.1 P 110 0.245 11 20.317 0.083 0.0041 15.1.2 P 110 0.245 27 20.155 0.245 0.0120 15.1.3 P 110 0.245 27 20.033 0.367 0.0180 15.1.4 P 110 0.245 9 20.006 0.394 0.0193 15.1.5 P 110 0.245 30 19.961 0.439 0.0215 END Z 0.000 0 19.961 0.439 0.0215 END Z 0.000 0 19.961 0.439 0.0215 END Z 0.000 0 19.961 0.439 0.0215 END Z 0.000 0 19.961 0.439 0.0215 END Z 0.000 0 19.961 0.439 0.0215 END Z 0.000 0 19.961 0.439 0.0215 END Z 0.000 0 19.961 0.439 0.0215 END Z 0.000 0 19.961 0.439 0.0215 END Z 0.000 0 19.961 0.439 0.0215 END Z 0.000 0 19.961 0.439 0.0215 END Z 0.000 0 19.961 0.439 0.0215 END Z 0.000 0 19.961 0.439 0.0215 END Z 0.000 0 19.961 0.439 0.0215 END Z 0.000 0 19.961 0.439 0.0215 END Z 0.000 0 19.961 0.439 0.0215 END Z 0.000 0 19.961 0.439 0.0215 Totals: 1.225 104 Point to Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 2.15% Current: 1.225 104 Distance: End Voltage Drop: 0.44 of Line Voltage: 19.96 CIRCUIT IS WITHIN LIMITS Percent Drop: 1.92% Load Centering Method Current: 1.225 Distance: Voltage Drop: 104 End of Line Voltage: 20.01 0.39 CIRCUIT IS WITHIN LIMITS Percent Drop: 3.83% Current: 1.225 End of Line Method Distance: End 104 Voltage Drop: 0.78 of Line Voltage: 19.62 PrOiect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP15 Circuit: NAC2 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0.491 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 7 14 3.07 237 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 15.2.1 P 30 0.101 7 20.379 0.021 0.0010 15.2.2 P 15 0.078 24 20.321 0.079 0.0039 15.2.3 P 15 0.078 52 20.222 0.178 0.0087 15.2.4 P 15 0.078 55 20.143 0.257 0.0126 15.2.5 P 15 0.078 52 20.093 0.307 0.0150 15.2.6 P 15 0.078 54 20.067 0.333 0.0163 END Z 0.000 0 20.067 0.333 0.0163 END Z 0.000 0 20.067 0.333 0.0163 END Z 0.000 0 20.067 0.333 0.0163 END Z 0.000 0 20.067 0.333 0.0163 END Z 0.000 0 20.067 0.333 0.0163 END Z 0.000 0 20.067 0.333 0.0163 END Z 0.000 0 20.067 0.333 0.0163 END Z 0.000 0 20.067 0.333 0.0163 END Z 0.000 0 20.067 0.333 0.0163 END Z 0.000 0 20.067 0.333 0.0163 END Z 0.000 0 20.067 0.333 0.0163 END Z 0.000 0 20.067 0.333 0.0163 END Z 0.000 0 20.067 0.333 0.0163 END Z 0.000 0 20.067 0.333 0.0163 END Z 0.000 0 20.067 0.333 0.0163 Totals: 0.491 244 CIRCUIT IS WITHIN LIMITS Percent Drop: 1.63% Current: 0.491 Point to Point Method 244 20.07 Distance: End of Line Voltage: 0.33 Voltage Drop: CIRCUIT IS WITHIN LIMITS Percent Drop: 1.80% Load Centering Method Current: 0.491 244 20.03 Distance: End of Line Voltage: 0.37 Voltage Drop: CIRCUIT IS WITHIN LIMITS Percent Drop: 3.61% Current: 0.491 End of Line Method 244 19.66 Distance: Voltage Drop: End of Line Voltage: 0.74 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP15 Circuit: NAC3 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 0 14 3.07 0 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 Totals: 0 0 CIRCUIT IS WITHIN LIMITS Percent Drop: Current: 0 0.00% Point to Point Method Distance: End Line Voltage: 0 20.40 Voltage Drop: 0.00 of Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 0 20.40 Distance: Voltage Drop: End of Line Voltage: 0.00 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 End of Line Method 0 20.40 Distance: Voltage Drop: End of Line Voltage: 0.00 Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP15 Circuit: NAC4 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.012 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 15 14 3.07 230 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 15.4.1 D 0.092 15 20.307 0.093 0.0046 15.4.2 D 0.092 19 20.199 0.201 0.0098 15.4.3 D 0.092 29 20.052 0.348 0.0171 15.4.4 D 0.092 21 19.957 0.443 0.0217 15.4.5 D 0.092 15 19.898 0.502 0.0246 15.4.6 D 0.092 27 19.806 0.594 0.0291 15.4.7 D 0.092 19 19.753 0.647 0.0317 15.4.8 D 0.092 25 19.696 0.704 0.0345 15.4.9 D 0.092 27 19.650 0.750 0.0367 15.4.10 D 0.092 24 19.623 0.777 0.0381 15.4.11 D 0.092 24 19.610 0.790 0.0387 END Z 0.000 0 19.610 0.790 0.0387 END Z 0.000 0 19.610 0.790 0.0387 END Z 0.000 0 19.610 0.790 0.0387 END Z 0.000 0 19.610 0.790 0.0387 END Z 0.000 0 19.610 0.790 0.0387 END Z 0.000 0 19.610 0.790 0.0387 END Z 0.000 0 19.610 0.790 0.0387 END Z 0.000 0 19.610 0.790 0.0387 END Z 0.000 0 19.610 0.790 0.0387 END Z 0.000 0 19.610 0.790 0.0387 Totals: 1.012 245 CIRCUIT IS WITHIN LIMITS Percent Drop: 3.87% Current: 1.012 Point to Point Method 245 19.61 Distance: End of Line Voltage: 0.79 Voltage Drop: CIRCUIT IS WITHIN LIMITS Percent Drop: 3.73% Current: 1.012 Load Centering Method 245 19.64 Distance: End of Line Voltage: 0.76 Voltage Drop: CIRCUIT IS WITHIN LIMITS Percent Drop: 7.46% Current: 1.012 End of Line Method 245 18.88 Distance: End of Line Voltage: 1.52 Voltage Drop: Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP15 Battery Calculations Standy Circuit / Device Current Alarm Current Qty Total Standy Current Total Alarm Current Power Supply 70 70 1 70 70 NAC Power NAC1 0 1225 1 0 1225 NAC2 0 491 1 0 491 NAC3 0 0 0 0 0 NAC4 66 1012 1 66 0 200 mA Aux Power Aux 0 0 0 0 0 Aux 0 0 0 0 0 Aux 0 0 0 0 0 TOTALS: 136 1786 Total Standy Current (Amps): 0.136 X 24 Hours: 3.264 Amphours in Standy Total Alarm Current (Amps): 1.786 X 15 Mins: 0.45 Amphours in Alarm 3.71 Required Amphours Required Amphours: +20% Safety 3.71 4.45 Total Margin Am hours P (2) 12V 8Ah Batteries Required. *Magnetic Door Holders are not included in the battery calculations. Power to these devices will be automatically disconnected upon loss of NC power to reduce battery size. DEVICE LEGEND Devices Current (Milliamps) Designator Part Number Description Light0uput 0 15cd 30cd 75cd 95cd 110cd 177cd -<X*<CHcnXODOzKr c_-2G)mmcJOo0> SB4U SB4U-LF GSA-SBT SIGA-AB4G-LF INT-7ATW INT-8ATW EG1F-HD EG1F-VM EG1F-HDVM EGCF-VM EGCF-VMH EGCF-HDVM EGCF-HDVMH G4LFWF-H G4LFWF-HVM G4HFWF-S7VMC GCHFWF-S7VMC INT-4ASW XXXX DHF-24120C CO1224T XXXX XXXX XXXX XXXX Sounder Base for V Series Detectors 520Hz Sounder Base for V Series Detectors Sounder Base for PCOS Detectors 520Hz Sounder Base for PCOS Detectors WP Wall Mount Horn/Strobe WP Wall Mount Horn/Strobe Wall Mount Horn Wall Mount Strobe Wall Mount Horn/Strobe Ceiling Mount Strobe Ceiling Mount High Candela Strobe Ceiling Mount Horn/Strobe Ceiling Mount High Candela Horn/Strobe Wall Mount 520Hz Horn Wall Mount 520Hz Horn/Strobe Wall Mount Speaker/Strobe Ceiling Mount Speaker/Strobe Weatherproof Speaker/Strobe XXXX Magnetic Door Hold-Open Carbon Monoxide Detector XXXX XXXX XXXX XXXX 28 92 52 92 180 _ 90 22 85 127 135 245 160 246 285 309 102 94 140 273 325 333 551 111 152 281 333 324 554 166 219 266 381 437 78 101 188 245 94 140 273 325 551 159 15 75 Z N/A END OF CIRCUIT Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP16 Circuit: NAC1 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.715 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 165 14 3.07 96 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 16.1.1 P 110 0.245 165 18.663 1.737 0.0852 16.1.2 P 110 0.245 19 18.491 1.909 0.0936 16.1.3 P 110 0.245 18 18.356 2.044 0.1002 16.1.4 P 110 0.245 9 18.302 2.098 0.1029 16.1.5 P 110 0.245 34 18.148 2.252 0.1104 16.1.6 P 110 0.245 9 18.121 2.279 0.1117 16.1.7 P 110 0.245 7 18.110 2.290 0.1122 END Z 0.000 0 18.110 2.290 0.1122 END Z 0.000 0 18.110 2.290 0.1122 END Z 0.000 0 18.110 2.290 0.1122 END Z 0.000 0 18.110 2.290 0.1122 END Z 0.000 0 18.110 2.290 0.1122 END Z 0.000 0 18.110 2.290 0.1122 END Z 0.000 0 18.110 2.290 0.1122 END Z 0.000 0 18.110 2.290 0.1122 END Z 0.000 0 18.110 2.290 0.1122 END Z 0.000 0 18.110 2.290 0.1122 END Z 0.000 0 18.110 2.290 0.1122 END Z 0.000 0 18.110 2.290 0.1122 END Z 0.000 0 18.110 2.290 0.1122 END Z 0.000 0 18.110 2.290 0.1122 Totals: 1.715 261 CIRCUIT IS WITHIN LIMITS Percent Drop: 11.22% Current: 1.715 Point to Point Method Distance: 261 18.11 End of Line Voltage: Voltage Drop: 2.29 CIRCUIT IS WITHIN LIMITS Percent Drop: 6.74% Load Centering Method Current: 1.715 Distance: 261 End of Line Voltage: 19.03 Voltage Drop: 1.37 CIRCUIT IS WITHIN LIMITS Percent Drop: 13.47% Current: 1 1.715 End of Line Method End Line Voltage: Distance:' 261 Voltage Drop: 2.75 of 17.65 Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP16 Circuit: NAC2 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 2.13 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 41 14 3.07 131 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 16.2.1 P 110 0.245 41 19.864 0.536 0.0263 16.2.2 P 110 0.245 9 19.760 0.640 0.0314 16.2.3 H 15 0.085 20 19.558 0.842 0.0413 16.2.4 P 110 0.245 12 19.444 0.956 0.0469 16.2.5 P 110 0.245 9 19.371 1.029 0.0504 16.2.6 P 110 0.245 6 19.332 1.068 0.0524 16.2.7 H 15 0.085 8 19.292 1.108 0.0543 16.2.8 P 110 0.245 51 19.062 1.338 0.0656 16.2.9 P 110 0.245 7 19.041 1.359 0.0666 16.2.10 P 110 0.245 9 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 Totals: 2.13 172 CIRCUIT IS WITHIN LIMITS Percent Drop: 6.73% Point to Point Method Current: 2.13 Distance: 172 End Line Voltage: 19.03 Voltage Drop: 1.37 of CIRCUIT IS WITHIN LIMITS Percent Drop: 5.51% Load Centering Method Current: 2.13 172 19.28 Distance: Voltage Drop: End of Line Voltage: 1.12 CIRCUIT IS WITHIN LIMITS Percent Drop: 11.03% Current: 2.13 End of Line Method 172 18.15 Distance: Voltage Drop: End of Line Voltage: 2.25 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP16 Circuit: NAC3 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.8 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 48 14 3.07 123 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 16.3.1 P 110 0.245 48 19.870 0.530 0.0260 16.3.2 P 110 0.245 9 19.784 0.616 0.0302 16.3.3 P 110 0.245 22 19.607 0.793 0.0389 16.3.4 H 15 0.085 9 19.548 0.852 0.0418 16.3.5 P 110 0.245 20 19.427 0.973 0.0477 16.3.6 P 110 0.245 22 19.328 1.072 0.0525 16.3.7 P 110 0.245 20 19.268 1.132 0.0555 16.3.8 P 110 0.245 21 19.236 1.164 0.0570 END Z 0.000 0 19.236 1.164 0.0570 END Z 0.000 0 19.236 1.164 0.0570 END Z 0.000 0 19.236 1.164 0.0570 END Z 0.000 0 19.236 1.164 0.0570 END Z 0.000 0 19.236 1.164 0.0570 END Z 0.000 0 19.236 1.164 0.0570 END Z 0.000 0 19.236 1.164 0.0570 END Z 0.000 0 19.236 1.164 0.0570 END Z 0.000 0 19.236 1.164 0.0570 END Z 0.000 0 19.236 1.164 0.0570 END Z 0.000 0 19.236 1.164 0.0570 END Z 0.000 0 19.236 1.164 0.0570 END Z 0.000 0 19.236 1.164 0.0570 Totals: 1.8 171 CIRCUIT IS WITHIN LIMITS Percent Drop: 5.70% Current: 1.8 Point to Point Method Distance: End Line Voltage: 171 Voltage Drop: 1.16 of 19.24 CIRCUIT IS WITHIN LIMITS Percent Drop: 4.63% Load Centering Method Current: 1.8 171 19.46 Distance: Voltage Drop: End of Line Voltage: 0.94 CIRCUIT IS WITHIN LIMITS Percent Drop: 9.26% Current: 1.8 End of Line Method Distance: End Line Voltage: 171 Voltage Drop: 1.89 of 18.51 Proiect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP16 Circuit: NAC4 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.472 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guage Ohms/ 1000' 41 14 3.07 312 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 16.4.1 D 0.092 41 20.029 0.371 0.0182 16.4.2 D 0.092 27 19.801 0.599 0.0294 16.4.3 D 0.092 16 19.674 0.726 0.0356 16.4.4 D 0.092 20 19.527 0.873 0.0428 16.4.5 D 0.092 26 19.351 1.049 0.0514 16.4.6 D 0.092 20 19.227 1.173 0.0575 16.4.7 D 0.092 22 19.102 1.298 0.0636 16.4.8 D 0.092 20 19.001 1.399 0.0686 16.4.9 D 0.092 21 18.906 1.494 0.0732 16.4.10 D 0.092 22 18.819 1.581 0.0775 16.4.11 D 0.092 19 18.755 1.645 0.0807 16.4.12 D 0.092 23 18.690 1.710 0.0838 16.4.13 D 0.092 21 18.642 1.758 0.0862 16.4.14 D 0.092 12 18.622 1.778 0.0872 16.4.15 D 0.092 23 18.596 1.804 0.0884 16.4.16 D 0.092 20 18.584 1.816 0.0890 END Z 0.000 0 18.584 1.816 0.0890 END Z 0.000 0 18.584 1.816 0.0890 END Z 0.000 0 18.584 1.816 0.0890 END Z 0.000 0 18.584 1.816 0.0890 END Z 0.000 0 18.584 1.816 0.0890 Totals: 1.472 353 Point Method CIRCUIT IS WITHIN LIMITS Percent Drop: 8.90% Current: 1.472 Point to Distance: 353 Voltage Drop: End of Line Voltage: 18.58 1.82 CIRCUIT IS WITHIN LIMITS Percent Drop: 7.82% Current: 1.472 Load Centering Method Distance: 353 Voltage Drop: End of Line Voltage: 18.80 1.60 CIRCUIT IS WITHIN LIMITS End Line Method Percent Drop: 15.64% Current: 1.472 of Distance: 353 Voltage Drop: End of Line Voltage: 17.21 3.19 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP16 Battery Calculations Standy Circuit / Device Current Alarm Current Qty Total Standy Current Total Alarm Current Power Supply 70 70 1 70 70 NAC Power NAC1 0 1715 1 0 1715 NAC2 0 2130 1 0 2130 NAC3 0 1800 1 0 1800 NAC4 96 1472 1 96 0 200 mA Aux Power Aux 0 0 0 0 0 Aux 0 0 0 0 0 Aux 0 0 0 0 0 TOTALS: 166 5715 Total Standy Current (Amps): 0.166 X 24 Hours: 3.984 Amphours in Standy Total Alarm Current (Amps): 5.715 X 15 Mins: 1.43 Amphours in Alarm 5.41 Required Amphours Required Amphours: 5.41 +20% Safety 6.50 Total Margin Amphours (2) 12V 8Ah Batteries Required. "Magnetic Door Holders are not included in the battery calculations. Power to these devices will be automatically disconnected upon loss of NC power to reduce battery size. DEVICE LEGEND Devices Current (Milliamps) Designator Part Number Description LightOuput 0 15cd 30cd 75cd 95cd 110cd 177cd A B C D E F G H I J K L M N 0 P Q R S T U V W X Y SB4U SB4U-LF GSA-SBT SIGA-AB4G-LF INT-7ATW INT-8ATW EG1F-HD EG1F-VM EG1F-HDVM EGCF-VM EGCF-VMH EGCF-HDVM EGCF-HDVMH G4LFWF-H G4LFWF-HVM G4HFWF-S7VMC GCHFWF-S7VMC INT-4ASW XXXX DHF -24120C C01224T )(XXX XXXX XXXX XXXX Sounder Base for V Series Detectors 520Hz Sounder Base for V Series Detectors Sounder Base for PCOS Detectors 520Hz Sounder Base for PCOS Detectors WP Wall Mount Horn/Strobe WP Wall Mount Horn/Strobe Wall Mount Horn Wall Mount Strobe Wall Mount Horn/Strobe Ceiling Mount Strobe Ceiling Mount High Candela Strobe Ceiling Mount Horn/Strobe Ceiling Mount High Candela Horn/Strobe Wall Mount 520Hz Horn Wall Mount 520Hz Horn/Strobe Wall Mount Speaker/Strobe Ceiling Mount Speaker/Strobe Weatherproof Speaker/Strobe XXXX Magnetic Door Hold -Open Carbon Monoxide Detector XXXX XXXX XXXX XXXX 28 92 52 92 180 90 22 85 102 127 135 245 160 246 285 309 94 140 273 325 333 551 111 152 281 333 324 554 166 219 266 381 437 78 101 188 245 94 140 273 325 551 159 15 75 Z N/A END OF CIRCUIT Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP17 Circuit: NAC1 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0.468 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaoe Ohms/ 1000' 15 14 3.07 223 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 17.1.1 P 15 0.078 15 20.357 0.043 0.0021 17.1.2 P 15 0.078 10 20.333 0.067 0.0033 17.1.3 P 15 0.078 52 20.233 0.167 0.0082 17.1.4 P 15 0.078 55 20.154 0.246 0.0120 17.1.5 P 15 0.078 52 20.105 0.295 0.0145 17.1.6 P 15 0.078 54 20.079 0.321 0.0158 END Z 0.000 0 20.079 0.321 0.0158 END Z 0.000 0 20.079 0.321 0.0158 END Z 0.000 0 20.079 0.321 0.0158 END Z 0.000 0 20.079 0.321 0.0158 END Z 0.000 0 20.079 0.321 0.0158 END Z 0.000 0 20.079 0.321 0.0158 END Z 0.000 0 20.079 0.321 0.0158 END Z 0.000 0 20.079 0.321 0.0158 END Z 0.000 0 20.079 0.321 0.0158 END Z 0.000 0 20.079 0.321 0.0158 END Z 0.000 0 20.079 0.321 0.0158 END Z 0.000 0 20.079 0.321 0.0158 END Z 0.000 0 20.079 0.321 0.0158 END Z 0.000 0 20.079 0.321 0.0158 END Z 0.000 0 20.079 0.321 0.0158 Totals: 0.468 238 CIRCUIT IS WITHIN LIMITS Percent Drop: 1.58% Current: 0.468 Point to Point Method 238 20.08 Distance: Voltage Drop: End of Line Voltage: 0.32 CIRCUIT IS WITHIN LIMITS Percent Drop: 1.68% Load Centering Method Current: 0.468 Distance: Voltage Drop: 238 End of Line Voltage: 20.06 0.34 CIRCUIT IS WITHIN LIMITS Percent Drop: 3.35% Current: 0.468 End of Line Method Distance: End 238 Voltage Drop: 0.68 of Line Voltage: 19.72 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP17 Circuit: NAC2 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.225 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 147 14 3.07 74 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 17.2.1 P 110 0.245 147 19.294 1.106 0.0542 17.2.2 P 110 0.245 16 19.198 1.202 0.0589 17.2.3 P 110 0.245 19 19.112 1.288 0.0631 17.2.4 P 110 0.245 18 19.058 1.342 0.0658 17.2.5 P 110 0.245 21 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 END Z 0.000 0 19.027 1.373 0.0673 Totals: 1.225 221 CIRCUIT IS WITHIN LIMITS Percent Drop: 6.73% Point to Point Method Current: 1.225 Distance: 221 Voltage Drop: End of Line Voltage: 19.03 1.37 CIRCUIT IS WITHIN LIMITS Percent Drop: 4.07% Load Centering Method Current: 1.225 221 19.57 Distance: Voltage Drop: End of Line Voltage: 0.83 CIRCUIT IS WITHIN LIMITS Percent Drop: 8.15% Current: 1.225 End of Line Method 221 18.74 Distance: Voltage Drop: End of Line Voltage: 1.66 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP17 Circuit: NAC3 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.31 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 65 14 3.07 102 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 17.3.1 P 110 0.245 65 19.877 0.523 0.0256 17.3.2 P 110 0.245 33 19.661 0.739 0.0362 17.3.3 P 110 0.245 9 19.616 0.784 0.0384 17.3.4 P 110 0.245 29 19.514 0.886 0.0434 17.3.5 H 15 0.085 8 19.497 0.903 0.0442 17.3.6 P 110 0.245 23 19.463 0.937 0.0459 END Z 0.000 0 19.463 0.937 0.0459 END Z 0.000 0 19.463 0.937 0.0459 END Z 0.000 0 19.463 0.937 0.0459 END Z 0.000 0 19.463 0.937 0.0459 END Z 0.000 0 19.463 0.937 0.0459 END Z 0.000 0 19.463 0.937 0.0459 END Z 0.000 0 19.463 0.937 0.0459 END Z 0.000 0 19.463 0.937 0.0459 END Z 0.000 0 19.463 0.937 0.0459 END Z 0.000 0 19.463 0.937 0.0459 END Z 0.000 0 19.463 0.937 0.0459 END Z 0.000 0 19.463 0.937 0.0459 END Z 0.000 0 19.463 0.937 0.0459 END Z 0.000 0 19.463 0.937 0.0459 END Z 0.000 0 19.463 0.937 0.0459 Totals: 1.31 167 CIRCUIT IS WITHIN LIMITS Percent Drop: 4.59% Current: 1.31 Point to Point Method Distance: End Line Voltage: 167 Voltage Drop: 0.94 of 19.46 CIRCUIT IS WITHIN LIMITS Percent Drop: 3.29% Load Centering Method Current: 1.31 Distance: Voltage Drop: 167 End of Line Voltage: 19.73 0.67 CIRCUIT IS WITHIN LIMITS Percent Drop: 6.58% Current: 1.31 End of Line Method Distance: End Line Voltage: 167 19.06 Voltage Drop: 1.34 of Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP17 Circuit: NAC4 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.472 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guage Ohms/ 1000' 71 14 3.07 302 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 17.4.1 D 0.092 71 19.758 0.642 0.0315 17.4.2 D 0.092 20 19.589 0.811 0.0398 17.4.3 D 0.092 19 19.439 0.961 0.0471 17.4.4 D 0.092 20 19.292 1.108 0.0543 17.4.5 D 0.092 17 19.176 1.224 0.0600 17.4.6 D 0.092 21 19.046 1.354 0.0664 17.4.7 D 0.092 18 18.944 1.456 0.0714 17.4.8 D 0.092 23 18.827 1.573 0.0771 17.4.9 D 0.092 19 18.742 1.658 0.0813 17.4.10 D 0.092 19 18.666 1.734 0.0850 17.4.11 D 0.092 25 18.582 1.818 0.0891 17.4.12 D 0.092 17 18.534 1.866 0.0915 17.4.13 D 0.092 25 18.477 1.923 0.0943 17.4.14 D 0.092 19 18.445 1.955 0.0958 17.4.15 D 0.092 19 18.423 1.977 0.0969 17.4.16 D 0.092 21 18.412 1.988 0.0975 END Z 0.000 0 18.412 1.988 0.0975 END Z 0.000 0 18.412 1.988 0.0975 END Z 0.000 0 18.412 1.988 0.0975 END Z 0.000 0 18.412 1.988 0.0975 END Z 0.000 0 18.412 1.988 0.0975 Totais: 1.472 373 CIRCUIT IS WITHIN LIMITS Point to Point Method Percent Drop: 9.75% Current: 1.472 Distance: 373 Voltage Drop: End of Line Voltage: 18.41 1.99 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 8.26% Current: 1.472 373 18.71 Distance: Voltage Drop: End of Line Voltage: 1.69 End Line Method CIRCUIT IS WITHIN LIMITS Percent Drop: 16.53% Current: 1.472 of Distance: 373 Voltage Drop: End of Line Voltage: 17.03 3.37 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP17 Battery Calculations Circuit / Device Standy Alarm Current Current Qty Total Standy Current Total Alarm Current Power Supply 70 70 1 70 70 NAC Power NAC1 0 468 1 0 468 NAC2 0 1225 1 0 1225 NAC3 0 1310 1 0 1310 NAC4 96 1472 1 96 0 200 mA Aux Power Aux 0 0 0 0 0 Aux 0 0 0 0 0 Aux 0 0 0 0 0 TOTALS: 166 3073 Total Standy Current (Amps): 0.166 X 24 Hours: 3.984 Amphours in Standy Total Alarm Current (Amps): 3.073 X 15 Mins: 0.77 Amphours in Alarm 4.75 Required Amphours +20% Safety Total Required Amphours: 4.75 Margin 5'70 Amphours hours (2) 12V 8Ah Batteries Required. *Magnetic Door Holders are not included in the battery calculations. Power to these devices will be automatically disconnected upon loss of NC power to reduce battery size. DEVICE LEGEND Devices Current (Milliamps) Designator Part Number Description Light Ouput 0 15cd 30cd 75cd 95cd 110cd 177cd A B C D E F G H I J K L M N 0 P Q R S T U V W X Y SB4U SB4U-LF GSA-SBT SIGA-AB4G-LF INT-7ATW INT-8ATW EG1F-HD EG1F-VM EG1F-HDVM EGCF-VM EGCF-VMH EGCF-HDVM EGCF-HDVMH G4LFWF-H G4LFWF-HVM G4HFWF-S7VMC GCHFWF-S7VMC INT-4ASW XXXX DHF -24120C CO1224T XXXX XXXX XXXX XXXX Sounder Base for V Series Detectors 520Hz Sounder Base for V Series Detectors Sounder Base for PCOS Detectors 520Hz Sounder Base for PCOS Detectors WP Wall Mount Horn/Strobe WP Wall Mount Horn/Strobe Wall Mount Horn Wall Mount Strobe Wall Mount Horn/Strobe Ceiling Mount Strobe Ceiling Mount High Candela Strobe Ceiling Mount Horn/Strobe Ceiling Mount High Candela Horn/Strobe Wall Mount 520Hz Horn Wall Mount 520Hz Horn/Strobe Wall Mount Speaker/Strobe Ceiling Mount Speaker/Strobe Weatherproof Speaker/Strobe XXXX Magnetic Door Hold -Open Carbon Monoxide Detector XXXX XXXX XXXX XXXX 28 92 52 92 180 90 22 85 127 245 285 102 135 160 246 309 94 140 273 325 333 551 111 152 281 333 324 554 166 219 266 381 437 78 101 188 245 94 140 273 325 551 159 15 75 Z N/A END OF CIRCUIT Prosect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP18 Circuit: NAC1 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.47 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 34 14 3.07 103 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 18.1.1 P 110 0.245 34 20.093 0.307 0.0150 18.1.2 P 110 0.245 19 19.950 0.450 0.0220 18.1.3 P 110 0.245 23 19.812 0.588 0.0288 18.1.4 P 110 0.245 19 19.726 0.674 0.0330 18.1.5 P 110 0.245 22 19.660 0.740 0.0363 18.1.6 P 110 0.245 20 19.630 0.770 0.0378 END Z 0.000 0 19.630 0.770 0.0378 END Z 0.000 0 19.630 0.770 0.0378 END Z 0.000 0 19.630 0.770 0.0378 END Z 0.000 0 19.630 0.770 0.0378 END Z 0.000 0 19.630 0.770 0.0378 END Z 0.000 0 19.630 0.770 0.0378 END Z 0.000 0 19.630 0.770 0.0378 END Z 0.000 0 19.630 0.770 0.0378 END- Z 0.000 0 19.630 0.770 0.0378 END Z 0.000 0 19.630 0.770 0.0378 END Z 0.000 0 19.630 0.770 0.0378 END Z 0.000 0 19.630 0.770 0.0378 END Z 0.000 0 19.630 0.770 0.0378 END Z 0.000 0 19.630 0.770 0.0378 END Z 0.000 0 19.630 0.770 0.0378 Totals: 1.47 137 CIRCUIT IS WITHIN LIMITS Percent Drop: 3.78% Current: 1.47 Point to Point Method Distance: End Line Voltage: 137 Voltage Drop: 0.77 of 19.63 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 3.03% Current: 1.47 137 19.78 Distance: Voltage Drop: End of Line Voltage: 0.62 CIRCUIT IS WITHIN LIMITS Percent Drop: 6.06% Current: 1.47 End of Line Method Distance: End Line 137 Voltage Drop: 1.24 of Voltage: 19.16 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP18 Circuit: NAC2 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0.592 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 5 14 3.07 219 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 18.2.1 P 30 0.101 5 20.382 0.018 0.0009 18.2.2 P 15 0.078 8 20.358 0.042 0.0021 18.2.3 P 30 0.101 29 20.284 0.116 0.0057 18.2.4 P 15 0.078 30 20.227 0.173 0.0085 18.2.5 P 15 0.078 52 20.152 0.248 0.0122 18.2.6 P 15 0.078 50 20.104 0.296 0.0145 18.2.7 P 15 0.078 50 20.080 0.320 0.0157 END Z 0.000 0 20.080 0.320 0.0157 END Z 0.000 0 20.080 0.320 0.0157 END Z 0.000 0 20.080 0.320 0.0157 END Z 0.000 0 20.080 0.320 0.0157 END Z 0.000 0 20.080 0.320 0.0157 END Z 0.000 0 20.080 0.320 0.0157 END Z 0.000 0 20.080 0.320 0.0157 END Z 0.000 0 20.080 0.320 0.0157 END Z 0.000 0 20.080 0.320 0.0157 END Z 0.000 0 20.080 0.320 0.0157 END Z 0.000 0 20.080 0.320 0.0157 END Z 0.000 0 20.080 0.320 0.0157 END Z 0.000 0 20.080 0.320 0.0157 END Z 0.000 0 20.080 0.320 0.0157 Totals: 0.592 224 CIRCUIT IS WITHIN LIMITS Point to Point Method Percent Drop: 1.57% Current: 0.592 224 20.08 Distance: End of Line Voltage: 0.32 Voltage Drop: CIRCUIT IS WITHIN LIMITS Percent Drop: 2.00% Load Centering Method Current: 0.592 224 19.99 Distance: End of Line Voltage: 0.41 Voltage Drop: CIRCUIT IS WITHIN LIMITS Percent Drop: 3.99% Current: 0.592 End of Line Method 224 19.59 Distance: End of Line Voltage: 0.81 Voltage Drop: Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP18 Circuit: NAC3 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.225 Amps Distance to 1st Device: Remaining Distance: System Type: Wire GGuaae Ohms/ 1000' 152 14 3.07 77 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 18.3.1 P 110 0.245 152 19.257 1.143 0.0560 18.3.2 P 110 0.245 19 19.142 1.258 0.0616 18.3.3 P 110 0.245 9 19.102 1.298 0.0636 18.3.4 P 110 0.245 40 18.981 1.419 0.0695 18.3.5 P 110 0.245 9 18.968 1.432 0.0702 END Z 0.000 0 18.968 1.432 0.0702 END Z 0.000 0 18.968 1.432 0.0702 END Z 0.000 0 18.968 1.432 0.0702 END Z 0.000 0 18.968 1.432 0.0702 END Z 0.000 0 18.968 1.432 0.0702 END Z 0.000 0 18.968 1.432 0.0702 END Z 0.000 0 18.968 1.432 0.0702 END Z 0.000 0 18.968 1.432 0.0702 END Z 0.000 0 18.968 1.432 0.0702 END Z 0.000 0 18.968 1.432 0.0702 END Z 0.000 0 18.968 1.432 0.0702 END Z 0.000 0 18.968 1.432 0.0702 END Z 0.000 0 18.968 1.432 0.0702 END Z 0.000 0 18.968 1.432 0.0702 END Z 0.000 0 18.968 1.432 0.0702 END Z 0.000 0 18.968 1.432 0.0702 Totals: 1.225 229 CIRCUIT IS WITHIN LIMITS Percent Drop: 7.02% Current: 1.225 Point to Point Method Distance: End Line Voltage: 229 Voltage Drop: 1.43 of 18.97 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 4.22% Current: 1.225 229 19.54 Distance: Voltage Drop: End of Line Voltage: 0.86 CIRCUIT IS WITHIN LIMITS Percent Drop: 8.44% Current: 1.225 End of Line Method Distance: End Line Voltage: 229 Voltage Drop: 1.72 of 18.68 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP18 Circuit: NAC4 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.012 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 33 14 3.07 212 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 18.4.1 D 0.092 33 20.195 0.205 0.0101 18.4.2 D 0.092 19 20.088 0.312 0.0153 18.4.3 D 0.092 22 19.976 0.424 0.0208 18.4.4 D 0.092 19 19.890 0.510 0.0250 18.4.5 D 0.092 22 19.803 0.597 0.0293 18.4.6 D 0.092 20 19.735 0.665 0.0326 18.4.7 D 0.092 19 19.681 0.719 0.0352 18.4.8 D 0.092 22 19.632 0.768 0.0377 18.4.9 D 0.092 22 19.594 0.806 0.0395 18.4.10 D 0.092 27 19.564 0.836 0.0410 18.4.11 D 0.092 20 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 END Z 0.000 0 19.553 0.847 0.0415 Totals: 1.012 245 CIRCUIT IS WITHIN LIMITS Percent Drop: 4.15% Current: 1.012 Point to Point Method 245 19.55 Distance: End of Line Voltage: 0.85 Voltage Drop: CIRCUIT IS WITHIN LIMITS Percent Drop: 3.73% Current: 1.012 Load Centering Method 245 19.64 Distance: End of Line Voltage: 0.76 Voltage Drop: CIRCUIT IS WITHIN LIMITS Percent Drop: 7.46% Current: 1.012 End of Line Method 245 18.88 Distance: Voltage Drop: End of Line Voltage: 1.52 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP18 Battery Calculations Standy Alarm Circuit / Device Current Current Qty Total Standy Current Total Alarm Current Power Supply 70 70 1 70 70 NAC Power NAC1 0 1470 1 0 1470 NAC2 0 592 1 0 592 NAC3 0 1225 1 0 1225 NAC4 66 1012 1 66 0 200 mA Aux Power Aux 0 0 0 0 0 Aux 0 0 0 0 0 Aux 0 0 0 0 0 TOTALS: 136 3357 Total Standy Current (Amps): 0.136 X 24 Hours: 3.264 Amphours in Standy Total Alarm Current (Amps): 3.357 X 15 Mins: 0.84 Amphours in Alarm 4.10 Required Amphours +20% Safety Total Required Amphours: 4.10 4'92 Margin Am hours p (2) 12V 8Ah Batteries Required. *Magnetic Door Holders are not included in the battery calculations. Power to these devices will be automatically disconnected upon Toss of A/C power to reduce battery size. DEVICE LEGEND Devices Current (Milliamps) Designator Part Number Description Light Ouput 0 15cd 30cd 75cd 95cd 110cd 177cd A B C D E F G H I J K L M N 0 P Q R S T U V W X Y SB4U SB4U-LF GSA-SBT SIGA-AB4G-LF INT-7ATW INT-8ATW EG1F-HD EG1F-VM EG1F-HDVM EGCF-VM EGCF-VMH EGCF-HDVM EGCF-HDVMH G4LFWF-H G4LFWF-HVM G4HFWF-S7VMC GCHFWF-S7VMC INT-4ASW XXXX DHF -24120C C01224T XXXX XXXX )(XXX XXXX Sounder Base for V Series Detectors 520Hz Sounder Base for V Series Detectors Sounder Base for PCOS Detectors 520Hz Sounder Base for PCOS Detectors WP Wall Mount Horn/Strobe WP Wall Mount Horn/Strobe Wall Mount Horn Wall Mount Strobe Wall Mount Horn/Strobe Ceiling Mount Strobe Ceiling Mount High Candela Strobe Ceiling Mount Horn/Strobe Ceiling Mount High Candela Horn/Strobe Wall Mount 520Hz Horn Wall Mount 520Hz Horn/Strobe Wall Mount Speaker/Strobe Ceiling Mount Speaker/Strobe Weatherproof Speaker/Strobe XXXX Magnetic Door Hold -Open Carbon Monoxide Detector XXXX )(XXX XXXX XXXX 28 92 52 92 180 90 22 85 127 245 285 102 135 160 246 309 94 140 273 325 333 551 111 152 281 333 324 554 166 219 266 381 437 78 101 188 245 94 140 273 325 551 159 15 75 Z N/A END OF CIRCUIT Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP19 Circuit: NAC1 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.225 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000` 12 14 3.07 88 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 19.1.1 P 110 0.245 12 20.310 0.090 0.0044 19.1.2 P 110 0.245 25 20.159 0.241 0.0118 19.1.3 P 110 0.245 23 20.056 0.344 0.0169 19.1.4 P 110 0.245 9 20.028 0.372 0.0182 19.1.5 P 110 0.245 31 19.982 0.418 0.0205 END Z 0.000 0 19.982 0.418 0.0205 END Z 0.000 0 19.982 0.418 0.0205 END Z 0.000 0 19.982 0.418 0.0205 END Z 0.000 0 19.982 0.418 0.0205 END Z 0.000 0 19.982 0.418 0.0205 END Z 0.000 0 19.982 0.418 0.0205 END Z 0.000 0 19.982 0.418 0.0205 END Z 0.000 0 19.982 0.418 0.0205 END Z 0.000 0 19.982 0.418 0.0205 END Z 0.000 0 19.982 0.418 0.0205 END Z 0.000 0 19.982 0.418 0.0205 END Z 0.000 0 19.982 0.418 0.0205 END Z 0.000 0 19.982 0.418 0.0205 END Z 0.000 0 19.982 0.418 0.0205 END Z 0.000 0 19.982 0.418 0.0205 END Z 0.000 0 19.982 0.418 0.0205 Totals: 1.225 100 CIRCUIT IS WITHIN LIMITS Percent Drop: 2.05% Current:' 1.225 Point to Point Method , 100 Distance: End Line Voltage: Voltage Drop: 0.42 of 19.98 CIRCUIT IS WITHIN LIMITS Percent Drop: 1.84% Load Centering Method Current: 1.225 Distance: Voltage Drop:, 100 End of Line Voltage: 20.02 0.38 CIRCUIT IS WITHIN LIMITS Percent Drop: 3.69% Current: 1.225 End of Line Method 100 19.65 Distance: Voltage Drop:; End of Line Voltage: 0.75 Protect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP19 Circuit: NAC2 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.47 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guage Ohms/ 1000' 102 14 3.07 115 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 19.2.1 P 110 0.245 102 19.479 0.921 0.0451 19.2.2 P 110 0.245 21 19.321 1.079 0.0529 19.2.3 P 110 0.245 22 19.189 1.211 0.0594 19.2.4 P 110 0.245 32 19.045 1.355 0.0664 19.2.5 P 110 0.245 16 j 18.996 1.404 0.0688 19.2.6 P 110 0.245 24 18.960 1.440 0.0706 END Z 0.000 0 18.960 1.440 0.0706 END Z 0.000 0 18.960 1.440 0.0706 END Z 0.000 0 18.960 1.440 0.0706 END Z 0.000 0 18.960 1.440 0.0706 END Z 0.000 0 18.960 1.440 0.0706 END Z 0.000 0 18.960 1.440 0.0706 END Z 0.000 0 18.960 1.440 0.0706 END Z 0.000 0 18.960 1.440 0.0706 END Z 0.000 0 18.960 1.440 0.0706 END Z 0.000 0 18.960 1.440 0.0706 END Z 0.000 0 18.960 1.440 0.0706 END Z 0.000 0 18.960 1.440 0.0706 END Z 0.000 0 18.960 1.440 0.0706 END Z 0.000 0 18.960 1.440 0.0706 END Z 0.000 0 18.960 1.440 0.0706 Totals: 1.47 217 CIRCUIT IS WITHIN LIMITS Percent Drop: 7.06% Point to Point Method Current: 1.47 217 18.96 Distance: Voltage Drop: End of Line Voltage: 1.44 CIRCUIT IS WITHIN LIMITS Percent Drop: 4.80% Load Centering Method Current: 1.47 217 19.42 Distance: Voltage Drop: End of Line Voltage: 0.98 CIRCUIT IS WITHIN LIMITS Percent Drop: 9.60% Current: 1.47 End of Line Method 217 Distance: Voltage Drop: End of Line Voltage: 18.44 1.96 Proiect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP19 Circuit: NAC3 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 0 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaae Ohms/ 1000' 0 14 3.07 0 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 END Z 0.000 0 20.400 0.000 0.0000 Totals: 0 0 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 Point to Point Method Distance: End 0 Voltage Drop: 0.00 of Line Voltage: 20.40 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 0 20.40 Distance: Voltage Drop: End of Line Voltage: 0.00 CIRCUIT IS WITHIN LIMITS Percent Drop: 0.00% Current: 0 End of Line Method 0 20.40 Distance: Voltage Drop: End of Line Voltage: 0.00 PrOiect: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP19 Circuit: NAC4 Minimum Panel Operating Voltage: Minimum Device Voltage: Total Circuit Current: 20.4 16 1.012 Amps Distance to 1st Device: Remaining Distance: System Type: Wire Guaoe Ohms/ 1000' 16 14 3.07 229 14 3.07 Low Frequency Device Address Device Type / Candela Distance Device from Current Previous (Amps) Device Voltage Drop Voltage at Drop From Device Source Percent Drop 19.4.1 D 0.092 16 20.301 0.099 0.0049 19.4.2 D 0.092 17 20.205 0.195 0.0096 19.4.3 D 0.092 24 20.083 0.317 0.0156 19.4.4 D 0.092 21 19.988 0.412 0.0202 19.4.5 D 0.092 16 19.924 0.476 0.0233 19.4.6 D 0.092 27 19.833 0.567 0.0278 19.4.7 D 0.092 24 19.765 0.635 0.0311 19.4.8 D 0.092 23 19.713 0.687 0.0337 19.4.9 D 0.092 27 19.667 0.733 0.0359 19.4.10 D 0.092 24 19.640 0.760 0.0372 19.4.11 D 0.092 26 19.626 0.774 0.0380 END Z 0.000 0 19.626 0.774 0.0380 END Z 0.000 0 19.626 0.774 0.0380 END Z 0.000 0 19.626 0.774 0.0380 END Z 0.000 0 19.626 0.774 0.0380 END Z 0.000 0 19.626 0.774 0.0380 END Z 0.000 0 19.626 0.774 0.0380 END Z 0.000 0 19.626 0.774 0.0380 END Z 0.000 0 19.626 0.774 0.0380 END Z 0.000 0 19.626 0.774 0.0380 END Z 0.000 0 19.626 0.774 0.0380 Totals: 1.012 245 CIRCUIT IS WITHIN LIMITS Percent Drop: 3.80% Current: 1.012 Point to Point Method Distance: 245 Voltage Drop: End of Line Voltage: 19.63 0.77 Load Centering Method CIRCUIT IS WITHIN LIMITS Percent Drop: 3.73% Current: 1.012 245 19.64 Distance: Voltage Drop: End of Line Voltage: 0.76 CIRCUIT IS WITHIN LIMITS Percent Drop: 7.46% Current: 1.012 End of Line Method 245 18.88 Distance: Voltage Drop: End of Line Voltage: 1.52 Project: Tukwila Element Panel Type: MIRBPS6A Panel Name: FAPP19 Battery Calculations Standy Circuit / Device Current Alarm Current Qty Total Standy Current Total Alarm Current Power Supply 70 70 1 70 70 NAC Power NAC1 0 1225 1 0 1225 NAC2 0 1470 1 0 1470 NAC3 0 0 0 0 0 NAC4 66 1012 1 66 0 200 mA Aux Power Aux 0 0 0 0 0 Aux 0 0 0 0 0 Aux 0 0 0 0 0 TOTALS: 136 2765 Total Standy Current (Amps): 0.136 X 24 Hours: 3.264 Amphours in Standy Total Alarm Current (Amps): 2.765 X 15 Mins: 0.69 Amphours in Alarm 3.96 Required . Amphours Required Amphours: +20% Safety 3.96 4'75 Total Margin Am hours p (2) 12V 8Ah Batteries Required. "Magnetic Door Holders are not included in the battery calculations. Power to these devices will be automatically disconnected upon loss of NC power to reduce battery size. DEVICE LEGEND Devices Current (Milliamps) Designator Part Number Description Light Ouput 0 15cd 30cd 75cd 95cd 110cd 177cd A B C D E F G H I J K L M N 0 P Q R S T U V W X Y SB4U SB4U-LF GSA-SBT SIGA-AB4G-LF INT-7ATW INT-8ATW EG1F-HD EG1F-VM EG1F-HDVM EGCF-VM EGCF-VMH EGCF-HDVM EGCF-HDVMH G4LFWF-H G4LFWF-HVM G4HFWF-S7VMC GCHFWF-S7VMC INT-4ASW XXXX DHF-24120C C01224T XXXX XXXX XXXX XXXX Sounder Base for V Series Detectors 520Hz Sounder Base for V Series Detectors Sounder Base for PCOS Detectors 520Hz Sounder Base for PCOS Detectors WP Wall Mount Horn/Strobe WP Wall Mount Horn/Strobe Wall Mount Horn Wall Mount Strobe Wall Mount Horn/Strobe Ceiling Mount Strobe Ceiling Mount High Candela Strobe Ceiling Mount Horn/Strobe Ceiling Mount High Candela Horn/Strobe Wall Mount 520Hz Horn Wall Mount 520Hz Horn/Strobe Wall Mount Speaker/Strobe Ceiling Mount Speaker/Strobe Weatherproof Speaker/Strobe XXXX Magnetic Door Hold-Open Carbon Monoxide Detector XXXX XXXX XXXX XXXX 28 92 52 92 180 90 22 85 127 245 246 285 309 102 135 160 94 140 273 325 333 551 111 152 281 333 324 554 166 219 266 381 437 78 101 188 245 94 140 273 325 551 159 15 75 Z N/A END OF CIRCUIT Element By Westin Job Name: oLocation: ;,Drawing Date: Contractor: Drawing Date:1-14-19 6/ 6/19 10:15 HYDRAULIC DESIGN INFORMATION SHEET Element By Westin 515 Industry Drive Tukwila, WA 99188 1-14-19 Total Fire Protection 1004 7th Ave. North Brandon, SD 57005 Designer: Greg Lindholm Calculated By:SprinkCAD www.sprinkcad.com 451 N. Cannon Ave. Lansdale, PA 19446 Construction: Reviewing Authorities: Remote Area Number: 1 Telephone:605-582-2400 Occupancy: SYSTEM DESIGN Code:NFPA 13 Hazard:Light System Type:WET Area of Sprinkler Oper. Density (gpm/sq ft) Area per Sprinkler Hose Allowance Inside Hose Allowance Outside RM Design) 0.150 204.0 sq ftl 0 gpm I 100 gpm 1 Sprinkler or Nozzle Make: Viking Model: VK484 K -Factor: 5.80 Temperature Rating: 155 CALCULATION SUMMARY 7 Flowing Outlets ••� Required: 346.9 psi Required: 106.0 @ Source WER SUPPLY Water Flow Test Date of Test 12-17-18 Static Pressure 150.0 psi Residual Pres 125.0 psi At a Flow of 8001 gpm Elevation 0" Pump Data Rated Capacity Rated Pressure Elevation Make: Model: 0 gpm 0.0 psi 0 Location: Source of Information: Tukwila Public Works SYSTEM VOLUME 1422 Gallons Notes: Element By Westin Drawing Date:1-14-19 6/ 6/19 10:15 HYDRAULIC CALCULATION DETAILS QTY DESCRIPTION Hydr Ref 1 3" Grvd 1 3" Grvd 1 4" Grvd 1 6" Grvd 1 8" Flngd HYDRAULIC LENGTH C ID W Required at Hyd Area 1 Butterfly Valve Tyco BFV- 9' 120 Check Valve Tyco CV-1FR CHART LOSS Butterfly Valve Tyco BFV- 5' 120 Butterfly Valve Tyco BFV- 11' 120 Back Flow Valve Deringe CHART LOSS Fixed Flow Flow Loss Elevation Change -6'0" FLOW gpm LOSS psi TOTALS 247 100.7 psi 3.068 247 0.6 247 0.9 4.026 247 0.1 6.065 247 0.0 247 6.2 100 gpm -2.6 Hydr Ref R1 Required at Source 347 106.0 psi Water Source150.0 psi static,125.0 psi residual @ 8001 gpm 347 gpm 149.9 psi SAFETY PRESSURE 43.9 psi Available Pressure of 149.9 psi Exceeds Required Pressure of 106.0 psi This is a safety margin of 43.9 psi or 29 % of Supply Maximum Water Velocity is 22.9 fps O 0 Element By Westin Drawing Date:l-14-19 6/ 6/19 10:15 Page 3 0 FITTING NAME TABLE ABBREV. NAME C Coupling E 90' Standard Elbow F 45' Elbow S Straight Flow Thru Tee T 90' Flow Thru Tee ✓ Valve LEGEND HYD REF Hydraulic reference. Refer to accompanying flow diagram. _ K FACTOR Flow factor for open head or path where Flow (gpm) = K x -\/P Qa Flow added or subtracted Qt Total flow DIA Actual internal diameter of pipe C Hazen Williams pipe roughness factor Pf/ft Friction loss per foot of pipe PIPE Length of pipe FTNG'S Number of fittings. See table above. TOTAL Total length (PIPE + FTNG'S) Pt Total pressure (psi) at fitting Pe Pressure due to change in elevation where Pe = 0.433 x change in elevation Friction loss (psi) to fitting where Pf = 1 x 4.52 x (Q/C)^1.85 / ID^4.87 Pv Velocity pressure (psi) where Pv = 0.001123 x Q^2/IDA4 Pn Normal pressure (psi), where Pn = Pt - Pv NOTES: - Pressures are balanced to 0.01 psi. Pressures are listed to 0.1 psi. Addition may vary by 0.1 psi due to accumulation of round off. - Calculations conform to NFPA 13. - Velocity Pressures are not considered in these Calculations Element By Westin Drawing Date:1-14-19 6/ 6/19 10:15 Page 4 NODE ELEVATION SPRINKLER PRESSURE ACTUAL MINIMUM ACTUAL NUMBER K -FACTOR FLOW FLOW DENSITY (FT) (GPM/(PSI^)) (PSI) (GPM) (GPM) (GPM/SQ.FT) 0 101 53.50 5.80 37.5 35.5 30.6 0.17 102 53.50 5.80 41.6 37.4 30.6 0.18 103 53.50 5.80 27.8 30.6 30.6 0.15 104 53.50 5.80 27.8 30.6 30.6 0.15 105 53.50 5.80 43.3 38.2 30.6 0.19 107 53.50 5.60 44.3 37.3 19.5 0.29 108 53.50 5.60 44.5 37.3 19.5 0.29 610 44.33 44.8 611 53.50 29.3 614 44.33 53.5 640 44.33 47.6 650 44.33 53.9 651 44.33 54.0 652 53.50 43.7 653 44.33 53.8 654 44.33 53.0 A2 44.33 54.8 A3 44.33 54.9 A4 44.33 55.1 A5 44.33 55.5 A6 44.33 77.5 A7 13.00 91.8 A8 13.00 92.0 A9 13.00 92.3 A10 -6.00 100.7 B6 14.00 91.1 B7 14.00 91.1 B8 14.00 91.1 B9 14.00 91.1 B10 14.00 91.1 G1 14.00 91.1 H2 44.33 54.8 I1 44.33 54.9 I2 44.33 54.9 J1 44.33 55.4 W -6.00 100.7 Max velocity of 22.94 occurs in the pipe from 610 TO 611 0 0 Element By Westin Drawing Date:1-14-19 6/ 6/19 Tyco Fire Products 10:15 Page 5 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv ******* NOTES ******* •INT Qt Pf/ft TOTAL Pf Pn PATH 1 FROM HYDRAULIC REFERENCE 104 TO W (PRIMARY PATH) 30.60 1.049 1T 0.15 27.8 27.8 K = 5.80 104 0=120 5.00 0.0 0.0 30.60 0.286 5.15 1.5 27.8 Vel = 11.47 30.60 1.049 1E 611 C=120 61.20 1.030 9.17 29.3 29.3 2.00 4.0 0.0 See PATH 2 11.17 11.5 29.3 Vel = 22.94 610 1.442 C=120 61.20 0.219 12.93 44.8 44.8 0.00 0.0 0.0 12.93 2.8 44.8 Vel = 12.14 35.52 1.442 1T 640 C=120 96.72 0.510 6.56 47.6 47.6 7.43 0.0 0.0 See PATH 3 14.00 7.1 47.6 Vel = 19.19 37.29 3.260 5.83 54.8 54.8 A2 C=120 0.00 0.0 0.0 See PATH 6 134.01 0.018 5.83 0.1 54.8 Vel = 5.20 G3 3.260 C=120 134.01 0.018 0.42 54.9 54.9 0.00 0.0 0.0 0.42 0.0 54.9 Vel = 5.20 I1 37.34 3.260 C=120 171.35 0.028 1.67 54.9 54.9 0.00 0.0 0.0 See PATH 7 1.67 0.0 54.9 Vel = 6.65 3.260 7.10 54.9 54.9 12 C=120 0.00 0.0 0.0 171.35 0.028 7.10 0.2 54.9 Vel = 6.65 37.39 3.260 6.65 55.1 55.1 A4 C=120 0.00 0.0 0.0 See PATH 4 208.74 0.040 6.65 0.3 55.1 Vel = 8.10 J1 38.16 3.260 C=120 246.90 0.054 2.88 55.4 55.4 0.00 0.0 0.0 See PATH 5 2.88 0.2 55.4 Vel = 9.58 3.260 1E 354.22 55.5 55.5 A5 0=120 2T 49.73 0.0 0.0 246.90 0.054 403.95 22.0 55.5 Vel = 9.58 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) Element By Westin Drawing Date:1-14-19 6/ 6/19 Tyco Fire Products 10:15 Page 6 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv ******* NOTES ******* POINT Qt Pf/ft TOTAL Pf Pn0 PATH 1 FROM HYDRAULIC REFERENCE 104 TO W (PRIMARY PATH) 4.260 30.33 77.5 77.5 A6 C=120 0.00 13.1 0.0 246.90 0.015 30.33 0.4 77.5 Vel = 5.61 G1 4.260 1E C=120 246.90 0.015 1.00 91.1 91.1 13.17 0.4 0.0 14.17 0.2 91.1 Vel = 5.61 4.260 1E 1.76 91.8 91.8 A7 C=120 13.17 0.0 0.0 246.90 0.015 14.93 0.2 91.8 Vel = 5.61 6.357 1T 101.14 92.0 92.0 A8 C=120 37.72 0.0 0.0 246.90 0.002 138.86 0.3 92.0 Vel = 2.52 6.357 2E 44.79 92.3 92.3 A9 C=120 35.21 8.2 0.0 246.90 0.002 79.99 0.2 92.3 Vel = 2.52 8.488 1E 113.62 100.7 100.7 A10 0=140 1F 45.89 0.0 0.0 246.90 0.000 159.51 0.1 100.7 Vel = 1.41 W 246.90 100.7 K = 24.60 PATH 2 FROM HYDRAULIC REFERENCE 103 TO 611 30.60 1.049 1T 103 C=120 30.60 0.286 0.15 27.8 27.8 K = 5.80 5.00 0.0 0.0 5.15 1.5 27.8 Vel = 11.47 611 30.60 29.3 K = 5.65 PATH 3 FROM HYDRAULIC REFERENCE 101 TO 640 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) 0 0 Element By Westin Drawing Date:1-14-19 6/ 6/19 10:15 Tyco Fire Products Page 7 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv ******* NOTES ******* LINT Qt Pf/ft TOTAL Pf Pn PATH 3 FROM HYDRAULIC REFERENCE 101 TO 640 CONTINUED 35.52 1.049 1E 9.32 37.5 37.5 K = 5.80 101 C=120 1T 7.00 4.0 0.0 35.52 0.377 16.32 6.1 37.5 Vel = 13.31 640 35.52 47.6 K = 5.15 PATH 4 FROM HYDRAULIC REFERENCE 102 TO A4 37.39 1.049 1T 102 C=120 37.39 0.414 0.15 41.6 41.6 K = 5.80 5.00 0.0 0.0 5.15 2.1 41.6 Vel = 14.02 1.049 1T 652 C=120 37.39 0.414 9.17 43.7 43.7 5.00 4.0 0.0 14.17 5.9 43.7 Vel = 14.02 ®614 1.442 1T 10.50 53.5 53.5 C=120 7.43 0.0 0.0 37.39 0.088 17.93 1.6 53.5 Vel = 7.42 A4 37.39 55.1 K = 5.04 PATH 5 FROM HYDRAULIC REFERENCE 105 TO J1 38.16 1.049 2E 105 C=120 38.16 0.430 9.42 43.3 43.3 K = 5.80 4.00 4.0 0.0 13.42 5.8 43.3 Vel = 14.30 654 1.442 C=120 38.16 0.091 8.16 53.0 53.0 0.00 0.0 0.0 8.16 0.7 53.0 Vel = 7.57 1.442 1T 10.08 53.8 53.8 653 C=120 7.43 0.0 0.0 38.16 0.091 17.51 1.6 53.8 Vel = 7.57 itSTS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) Element By Westin Drawing Date:1-14-19 6/ 6/19 Tyco Fire Products 10:15 Page 8 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv ******* NOTES ******* POINT Qt Pf/ft TOTAL Pf Pn0 J1 38.16 55.4 K = 5.13 PATH 6 FROM HYDRAULIC REFERENCE 107 TO A2 37.29 1.049 2E 9.42 44.3 44.3 K = 5.60 107 C=120 4.00 4.0 0.0 37.29 0.412 13.42 5.5 44.3 Vel = 13.98 1.442 1T 650 C=120 37.29 0.088 2.80 53.9 53.9 7.43 0.0 0.0 10.24 0.9 53.9 Vel = 7.40 3.260 3.76 54.8 54.8 H2 C=120 0.00 0.0 0.0 37.29 0.002 3.76 0.0 54.8 Vel = 1.45 A2 37.29 54.8 K = 5.04 PATH 7 FROM HYDRAULIC REFERENCE 108 TO I1 i+ 37.34 1.049 2E 108 C=120 37.34 0.413 9.42 44.5 44.5 K = 5.60 4.00 4.0 0.0 13.42 5.5 44.5 Vel = 14.00 1.442 1T 651 C=120 37.34 0.088 2.80 54.0 54.0 7.43 0.0 0.0 10.24 0.9 54.0 Vel = 7.41 I1 37.34 54.9 K = 5.04 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) 0 0 rn rn 000 Q— O d O o .i..; =ak N O. 0. N N G. 0) O) 0. C. ON-r-0ao O N M N N N a)a)� ooaa • ALL= w cr w CO ss - m L (0 13 acncncn= 0. a 7 (1) • 100 gpm hose CO N CD N r co am - 1.00 0 0 O O. O a) M 3 0 LL O O M 0 N 0 0 N Element By Westin Drawing Date:1-14-19 6/ 6/19 10:16 HYDRAULIC DESIGN INFORMATION SHEET Job Name: Element By Westin Location: 515 Industry Drive Tukwila, WA 99188 D,kawing Date: 1-14-19 Contractor: Total Fire Protection 1004 7th Ave. North Brandon, SD 57005 Designer: Greg Lindholm Calculated By:SprinkCAD www.sprinkcad.com 451 N. Cannon Ave. Lansdale, PA 19446 Construction: Reviewing Authorities: Remote Area Number: 2 Telephone:605-582-2400 Occupancy: SYSTEM DESIGN Code:NFPA 13 Hazard:Light System Type:WET Area of Sprinkler Oper. Density (gpm/sq ft) Area per Sprinkler Hose Allowance Inside Hose Allowance Outside RM Design' 0.150 324.0 sq ftl 0 gpm 100 gpm Sprinkler or Nozzle Make: Viking Model: VK472 K -Factor: 7.40 Temperature Rating: 155 CALCULATION SUMMARY cm Required: 438.1 WATER SUPPLY 7 Flowing Outlets psi Required: 130.2 @ Source Water Flow Test Date of Test 12-17-18 Static Pressure 150.0 psi Residual Pres 125.0 psi At a Flow of 8001 gpm Elevation 0" Pump Data Rated Capacity 0 gpm Rated Pressure 0.0 psi Elevation 0 Make: Model: Location: Source of Information: Tukwila Public Works SYSTEM VOLUME 1422 Gallons Notes: Element By Westin Drawing Date:1-14-19 6/ 6/19 10:16 HYDRAULIC CALCULATION DETAILS QTY DESCRIPTION HYDRAULIC FLOW LOSS LENGTH C ID gpm psi TOTALS Hydr Ref W Required at Hyd Area 2 338 123.9 psi 1 3" Grvd Butterfly Valve Tyco BFV- 9' 120 3.068 338 1.1 1 3" Grvd Check Valve Tyco CV-1FR CHART LOSS 338 1.3 1 4" Grvd Butterfly Valve Tyco BFV- 5' 120 4.026 338 0.2 1 6" Grvd Butterfly Valve Tyco BFV- 11' 120 6.065 338 0.1 1 8" Flngd Back Flow Valve Deringe CHART LOSS 338 6.2 Fixed Flow Flow Loss 100 gpm Elevation Change -6'0" -2.6 Hydr Ref R1 Required at Source 438 130.2 psi Water Source150.0 psi static,125.0 psi residual @ 8001 gpm 438 gpm 149.9 psi SAFETY PRESSURE 19.7 psi Available Pressure of 149.9 psi Exceeds Required Pressure of 130.2 psi This is a safety margin of 19.7 psi or 13 % of Supply Maximum Water Velocity is 20.3 fps 0 0 Element By Westin Drawing Date:1-14-19 6/ 6/19 10:16 Page 3 0 FITTING NAME TABLE ABBREV. NAME C Coupling E 90' Standard Elbow F 45' Elbow S Straight Flow Thru Tee T 90' Flow Thru Tee ✓ Valve LEGEND HYD REF Hydraulic reference. Refer to accompanying flow diagram. _ K FACTOR Flow factor for open head or path where Flow (gpm) = K x -\/P Qa Flow added or subtracted Qt Total flow DIA Actual internal diameter of pipe C Hazen Williams pipe roughness factor Pf/ft Friction loss per foot of pipe PIPE Length of pipe FTNG'S Number of fittings. See table above. TOTAL Total length (PIPE + FTNG'S) Pt Total pressure (psi) at fitting Pe Pressure due to change in elevation where Pe = 0.433 x change in elevation 4111, Friction loss (psi) to fitting where Pf = 1 x 4.52 x (Q/C)^1.85 / ID^4.87 Pv Velocity pressure (psi) where Pv = 0.001123 x QA2/IDA4 Pn Normal pressure (psi), where Pn = Pt - Pv NOTES: - Pressures are balanced to 0.01 psi. Pressures are listed to 0.1 psi. Addition may vary by 0.1 psi due to accumulation of round off. - Calculations conform to NFPA 13. - Velocity Pressures are not considered in these Calculations 0 Element By Westin Drawing Date:1-14-19 6/ 6/19 10:16 Page 4 NODE ELEVATION SPRINKLER PRESSURE ACTUAL MINIMUM ACTUAL NUMBER K -FACTOR FLOW FLOW DENSITY (FT) (GPM/(PSI^'-)) (PSI) (GPM) (GPM) (GPM/SQ.FT) 201 44.33 45.5 2015 43.00 7.40 44.3 202 44.33 44.4 2025 43.00 7.40 43.1 203 44.33 52.5 2035 43.00 7.40 48.8 204 44.33 50.8 2045 43.00 7.40 47.2 205 44.33 54.9 2055 43.00 7.40 53.3 207 44.33 5.60 55.8 208 44.33 5.60 56.1 612 44.33 50.1 613 44.33 48.8 614 44.33 56.3 Al 44.33 58.5 A2 44.33 58.6 A3 44.33 58.8 A4 44.33 59.4 A5 44.33 60.3 A6 44.33 99.6 A7 13.00 114.4 A8 13.00 114.8 A9 13.00 115.3 A10 -6.00 123.8 B6 14.00 113.6 B7 14.00 113.6 B8 14.00 113.6 B9 14.00 113.6 B10 14.00 113.6 G1 14.00 113.6 H1 44.33 58.6 H2 44.33 58.6 I1 44.33 58.8 I2 44.33 58.9 J1 44.33 60.0 W -6.00 123.9 49.2 48.6 51.7 50.8 54.0 41.8 41.9 Max velocity of 20.33 occurs in the pipe from 203 TO Al 48.6 48.6 48.6 48.6 48.6 14.8 14.8 Nodes with "S" indicate a node at the top of a sprig or bottom of drop pendent. The node without an "S" is on the branch. 0.15 0.15 0.16 0.16 0.17 0.50 0.50 0 0 Element By Westin Drawing Date:1-14-19 6/ 6/19 Tyco Fire Products 10:16 Page 5 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv ******* NOTES ******* POINT Qt Pf/ft TOTAL Pf Pn PATH 1 FROM HYDRAULIC REFERENCE 202 TO W (PRIMARY PATH) 48.60 1.101 1E 1.33 43.1 43.1 K = 7.40 202S 0=150 3.83 -0.6 0.0 48.60 0.352 5.16 1.8 43.1 Vel = 16.54 1.049 1T 1.66 44.4 44.4 EqK = 7.30 202 0=120 5.00 0.0 0.0 48.60 0.673 6.66 4.5 44.4 Vel = 18.22 613 1.442 C=120 48.60 0.143 9.00 48.8 48.8 0.00 0.0 0.0 9.00 1.3 48.8 Vel = 9.64 49.23 1.442 1T 612 C=120 97.83 0.521 9.11 50.1 50.1 7.43 0.0 0.0 See PATH 2 16.55 8.6 50.1 Vel = 19.41 144.33 3.260 0.42 58.8 58.8 A3 C=120 0.00 0.0 0.0 See PATH 3 242.16 0.052 0.42 0.0 58.8 Vel = 9.40 0 I1 3.260 C=120 242.16 0.052 1.67 58.8 58.8 0.00 0.0 0.0 1.67 0.1 58.8 Vel = 9.40 41.93 3.260 7.10 58.9 58.9 I2 C=120 0.00 0.0 0.0 See PATH 6 284.09 0.070 7.10 0.5 58.9 Vel = 11.03 54.03 3.260 6.65 59.4 59.4 A4 C=120 0.00 0.0 0.0 See PATH 4 338.12 0.097 6.65 0.6 59.4 Vel = 13.12 J1 3.260 C=120 338.12 0.097 2.88 60.0 60.0 0.00 0.0 0.0 2.88 0.3 60.0 Vel = 13.12 3.260 1E 354.22 60.3 60.3 A5 0=120 2T 49.73 0.0 0.0 338.12 0.097 403.95 39.3 60.3 Vel = 13.12 UNITS - DIAMETER (INCH) LENGTH (FOOT) 0 FLOW (GPM) PRESSURE (PSI) Element By Westin Drawing Date:l-14-19 6/ 6/19 Tyco Fire Products 10:16 Page 6 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv ******* NOTES ******* POINT Qt Pf/ft TOTAL Pf Pn PATH 1 FROM HYDRAULIC REFERENCE 202 TO W (PRIMARY PATH) 4.260 30.33 99.6 99.6 A6 C=120 0.00 13.1 0.0 338.12 0.026 30.33 0.8 99.6 Vel = 7.69 G1 4.260 1E 1.00 113.6 113.6 C=120 13.17 0.4 0.0 338.12 0.026 14.17 0.4 113.6 Vel = 7.69 4.260 1E 1.76 114.4 114.4 A7 C=120 13.17 0.0 0.0 338.12 0.026 14.93 0.4 114.4 Vel = 7.69 6.357 1T 101.14 114.8 114.8 A8 C=120 37.72 0.0 0.0 338.12 0.004 138.86 0.5 114.8 Vel = 3.45 6.357 2E 44.79 115.3 115.3 A9 C=120 35.21 8.2 0.0 338.12 0.004 79.99 0.3 115.3 Vel = 3.45 8.488 1E 113.62 123.8 123.8 A10 C=140 1F 45.89 0.0 0.0 338.12 0.001 159.51 0.1 123.8 Vel = 1.94 W 338.12 123.9 K = 30.37 PATH 2 FROM HYDRAULIC REFERENCE 201 TO 612 49.23 1.101 1E 1.33 44.3 44.3 K = 7.40 201S C=150 3.83 -0.6 0.0 49.23 0.360 5.16 1.9 44.3 Vel = 16.75 1.049 1T 1.66 45.5 45.5 EqK = 7.30 201 C=120 5.00 0.0 0.0 49.23 0.689 6.66 4.6 45.5 Vel = 18.46 612 49.23 50.1 K = 6.95 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) 0 0 Element By Westin Drawing Date:1-14-19 6/ 6/19 Tyco Fire Products 10:16 Page 7 0 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv ******* NOTES ******* POINT Qt Pf/ft TOTAL Pf Pn PATH 3 FROM HYDRAULIC REFERENCE 204 TO A3 2045 50.82 1.101 1T C=150 50.82 0.382 1.33 47.2 47.2 K = 7.40 9.56 -0.6 0.0 10.90 4.2 47.2 Vel = 17.29 204 1.442 C=120 50.82 0.155 11.21 50.8 50.8 EqK = 7.13 0.00 0.0 0.0 11.21 1.7 50.8 Vel = 10.08 51.68 1.442 lE 203 C=120 102.50 0.568 6.91 52.5 52.5 EqK = 7.13 3.72 0.0 0.0 10.63 6.0 52.5 Vel = 20.33 Al 3.260 2.94 58.5 58.5 C=120 0.00 0.0 0.0 102.50 0.011 2.94 0.0 58.5 Vel = 3.98 H1 41.82 3.260 C=120 144.33 0.020 0.33 58.6 58.6 0.00 0.0 0.0 See PATH 5 0.33 0.0 58.6 Vel = 5.60 0 H2 3.260 3.76 58.6 58.6 C=120 0.00 0.0 0.0 144.33 0.020 3.76 0.1 58.6 Vel = 5.60 3.260 5.83 58.6 58.6 A2 C=120 0.00 0.0 0.0 144.33 0.020 5.83 0.1 58.6 Vel = 5.60 A3 144.33 58.8 K = 18.83 51.68 1.101 1T 1.33 48.8 48.8 K = 7.40 2035 C=150 9.56 -0.6 0.0 51.68 0.394 10.90 4.3 48.8 Vel = 17.59 203 51.68 52.5 K = 7.13 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) Element By Westin Drawing Date:1-14-19 6/ 6/19 10:16 Tyco Fire Products Page 8 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv ******* NOTES ******* POINT Qt Pf/ft TOTAL Pf Pn PATH 4 FROM HYDRAULIC REFERENCE 205 TO A4 54.03 1.101 1E 1.33 53.3 53.3 K = 7.40 205S 0=150 3.83 -0.6 0.0 54.03 0.428 5.16 2.2 53.3 Vel = 18.38 1.442 7.62 54.9 54.9 EqK = 7.29 205 0=120 0.00 0.0 0.0 54.03 0.174 7.62 1.3 54.9 Vel = 10.72 1.442 1T 10.50 56.3 56.3 614 0=120 7.43 0.0 0.0 54.03 0.174 17.93 3.1 56.3 Vel = 10.72 A4 54.03 59.4 K = 7.01 PATH 5 FROM HYDRAULIC REFERENCE 207 TO H1 41.82 1.049 1T 0.47 55.8 55.8 K = 5.60 207 0=120 5.00 0.0 0.0 41.82 0.509 5.47 2.8 55.8 Vel = 15.68 H1 41.82 58.6 K = 5.47 PATH 6 FROM HYDRAULIC REFERENCE 208 TO I2 41.93 1.049 1T 208 C=120 41.93 0.512 0.47 56.1 56.1 K = 5.60 5.00 0.0 0.0 5.47 2.8 56.1 Vel = 15.72 12 41.93 58.9 K = 5.47 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) 0 0 0 d u 3 rn rn poo a— O m Ti yal (0 as (0 0. 0) 0) O. 0. NOOOON.N M M N e- a) a) a) m• �3oaa 3 (LL= �W cr N y 0) i.- >. >.. CU -0 Q..�c/)�I _a 00.0) CO 001- 0 10 8 rc00 a) 03 "0)N �0rn .. 3N Q of a) C =O O Nr m WLnHCe • N N0 100 gpm hose C144 J, 7 • N d N N N 00O0 0 0 O (0 v O 0 O 0 M 0 (t) N 0 0 N 0 O O Element By Westin 0 Job Name: Location: Drawing Date: -4 Contractor: Drawing Date:1-14-19 6/ 6/19 10:18 HYDRAULIC DESIGN INFORMATION SHEET Element By Westin 515 Industry Drive Tukwila, WA 99188 1-14-19 Total Fire Protection 1004 7th Ave. North Brandon, SD 57005 Designer: Greg Lindholm Calculated By:SprinkCAD www.sprinkcad.com 451 N. Cannon Ave. Lansdale, PA 19446 Construction: Reviewing Authorities: Remote Area Number: 3 Telephone:605-582-2400 Occupancy: SYSTEM DESIGN Code:NFPA 13 Hazard:Ord. Grp. I System Type:WET Area of Sprinkler Oper. Density (gpm/sq ft) Area per Sprinkler Hose Allowance Inside Hose Allowance Outside 953 sq ftl 0.150 130.0 sq ftl 0 gpm I 250 gpm I Sprinkler or Nozzle Make: Viking Model: VK302 K -Factor: 5.60 Temperature Rating: 155 CALCULATION SUMMARY cfm Required: 452.6 WATER SUPPLY 10 Flowing Outlets psi Required: 128.9 @ Source Water Flow Test Date of Test 12-17-18 Static Pressure 150.0 psi Residual Pres 125.0 psi At a Flow of 8001 gpm Elevation 0" Pump Data Rated Capacity 0 gpm Rated Pressure 0.0 psi Elevation 0 Make: Model: Location: Source of Information: Tukwila Public Works SYSTEM VOLUME 1422 Gallons Notes: Element By Westin Drawing Date:1-14-19 6/ 6/19 10:18 HYDRAULIC CALCULATION DETAILS QTY DESCRIPTION HYDRAULIC FLOW LOSS LENGTH C ID gpm psi TOTALS Hydr Ref W Required at Hyd Area 3 203 1 3" Grvd Butterfly Valve Tyco BFV- 9' 120 3.068 203 0.4 1 3" Grvd Check Valve Tyco CV-1FR CHART LOSS 203 0.8 1 4" Grvd Butterfly Valve Tyco BFV- 5' 120 4.026 203 0.1 1 6" Grvd Butterfly Valve Tyco BFV- 11' 120 6.065 203 0.0 1 8" Flngd Back Flow Valve Deringe CHART LOSS 203 5.1 Fixed Flow Flow Loss 250 gpm Elevation Change -6'0" -2.6 125.1 psi Hydr Ref R1 Required at Source 453 128.9 psi Water Source150.0 psi static,125.0 psi residual @ 8001 gpm 453 gpm 149.9 psi SAFETY PRESSURE 21.0 psi Available Pressure of 149.9 psi Exceeds Required Pressure of 128.9 psi This is a safety margin of 21.0 psi or 14 % of Supply Maximum Water Velocity is 18.0 fps 0 0 Element By Westin Drawing Date:1-14-19 6/ 6/19 10:18 Page 3 HYD REF K FACTOR Qa Qt DIA C Pf/ft PIPE FTNG'S TOTAL Pt Pe Pv Pn NOTES: ABBREV. FITTING NAME TABLE NAME C Coupling E 90' Standard Elbow F 45' Elbow S Straight Flow Thru Tee T 90' Flow Thru Tee V Valve LEGEND Hydraulic reference. Refer to accompanying flow diagram. _ Flow factor for open head or path where Flow (gpm) = K x -\/P Flow added or subtracted Total flow Actual internal diameter of pipe Hazen Williams pipe roughness factor Friction loss per foot of pipe Length of pipe Number of fittings. See table above. Total length (PIPE + FTNG'S) Total pressure (psi) at fitting Pressure due to change in elevation where Pe = 0.433 x change in elevation Friction loss (psi) to fitting where Pf = 1 x 4.52 x (Q/C)^1.85 / ID^4.87 Velocity pressure (psi) where Pv = 0.001123 x QA2/IDA4 Normal pressure (psi), where Pn = Pt - Pv - Pressures are balanced to 0.01 psi. Pressures are listed to 0.1 psi. Addition may vary by 0.1 psi due to accumulation of round off. - Calculations conform to NFPA 13. - Velocity Pressures are not considered in these Calculations Element By Westin Drawing Date:1-14-19 6/ 6/19 10:18 Page 4 NODE ELEVATION SPRINKLER PRESSURE ACTUAL MINIMUM ACTUAL NUMBER K -FACTOR FLOW FLOW DENSITY (FT) (GPM/(PSI^'1)) (PSI) (GPM) (GPM) (GPM/SQ.FT) 301 14.00 302 14.00 303 14.00 3035 8.00 304 14.00 3045 8.00 305 14.00 3055 8.00 306 14.00 3065 8.00 307 14.00 3075 8.00 308 14.00 3085 8.00 309 14.00 3095 8.00 310 14.00 3105 8.00 616 14.00 617 14.00 618 14.00 619 14.00 620 14.00 621 14.00 622 14.00 623 14.00 624 14.00 625 14.00 A7 13.00 A8 13.00 A9 13.00 A10 -6.00 B1 14.00 B2 14.00 B3 14.00 B4 14.00 B5 14.00 B6 14.00 B7 14.00 B8 14.00 B9 14.00 B10 14.00 G1 14.00 W -6.00 5.60 5.60 5.60 5.60 5.60 5.60 5.60 5.60 5.60 5.60 15.8 16.2 11.4 12.9 11.7 13.2 10.7 12.3 11.0 12.6 10.3 11.9 10.6 12.2 10.2 11.9 10.5 12.1 11.3 11.0 11.4 11.1 11.8 11.5 12.5 12.2 17.2 16.8 116.3 116.5 116.7 125.1 13.1 13.2 13.7 14.5 19.6 22.2 28.6 53.7 68.2 112.4 115.8 125.1 22.3 19.5 22.6 19.5 20.1 20.4 19.6 19.9 19.3 19.6 19.3 19.5 Max velocity of 17.96 occurs in the pipe from B5 TO B6 19.5 19.5 18.0 19.5 18.0 19.5 14.8 19.5 Nodes with "S" indicate a node at the top of a sprig or bottom of drop pendent. The node without an "S" is on the branch. 0.17 0.17 0.15 0.16 0.16 0.15 0.16 0.15 0.20 0.15 0 0 Element By Westin Drawing Date:1-14-19 6/ 6/19 Tyco Fire Products 10:18 Page 5 HYD. Qa DIA. FITTING PIPE Pt Pt 0 REF "C" TYPES FTNG'S Pe Pv ******* NOTES ******* POINT Qt Pf/ft TOTAL Pf Pn PATH 1 FROM HYDRAULIC REFERENCE 309 TO W (PRIMARY PATH) 309S 19.28 1.049 1E C=120 19.28 0.122 6.00 11.9 11.9 K = 5.60 2.00 -2.6 0.0 8.00 1.0 11.9 Vel = 7.23 1.049 1T 1.14 10.2 10.2 EqK = 6.03 309 C=120 5.00 0.0 0.0 19.28 0.122 6.14 0.7 10.2 Vel = 7.23 617 1.442 C=120 19.28 0.026 12.00 11.0 11.0 0.00 0.0 0.0 12.00 0.3 11.0 Vel = 3.82 19.50 1.442 1T 11.85 11.3 11.3 616 C=120 7.43 0.0 0.0 See PATH 3 38.78 0.094 19.28 1.8 11.3 Vel = 7.69 B1 2.157 8.00 13.1 13.1 C=120 0.00 0.0 0.0 38.78 0.013 8.00 0.1 13.1 Vel = 3.44 0 B2 38.91 2.157 C=120 77.69 0.048 10.00 13.2 13.2 0.00 0.0 0.0 See PATH 2 10.00 0.5 13.2 Vel = 6.89 39.51 2.157 8.00 13.7 13.7 B3 C=120 0.00 0.0 0.0 See PATH 5 117.20 0.102 8.00 0.8 13.7 Vel = 10.39 40.51 2.157 2E 16.61 14.5 14.5 B4 C=120 12.31 0.0 0.0 See PATH 7 157.71 0.177 28.92 5.1 14.5 Vel = 13.98 44.85 2.157 9.11 19.6 19.6 B5 C=120 0.00 0.0 0.0 See PATH 9 202.56 0.282 9.11 2.6 19.6 Vel = 17.96 -74.86 2.157 53.54 22.2 22.2 B6 C=120 0.00 0.0 0.0 See PATH 11 127.70 0.120 53.54 6.4 22.2 Vel = 11.32 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) Element By Westin Drawing Date:1-14-19 6/ 6/19 Tyco Fire Products 10:18 Page 6 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv ******* NOTES ******* POINT Qt Pf/ft TOTAL Pf Pn PATH 1 FROM HYDRAULIC REFERENCE 309 TO W (PRIMARY PATH) 74.86 2.157 1T 76.59 28.6 28.6 B7 C=120 12.31 0.0 0.0 See PATH 11 202.56 0.282 88.90 25.1 28.6 Vel = 17.96 2.157 1T 39.27 53.7 53.7 B8 C=120 12.31 0.0 0.0 202.56 0.282 51.57 14.5 53.7 Vel = 17.96 2.157 1E 138.26 68.2 68.2 B9 C=120 1T 18.46 0.0 0.0 202.56 0.282 156.72 44.2 68.2 Vel = 17.96 2.635 1E 7.30 112.4 112.4 B10 C=120 1T 24.71 0.0 0.0 202.56 0.106 32.01 3.4 112.4 Vel = 12.03 G1 4.260 1E C=120 202.56 0.010 1.00 115.8 115.8 13.17 0.4 0.0 14.17 0.1 115.8 Vel = 4.60 4.260 1E 1.76 116.3 116.3 A7 C=120 13.17 0.0 0.0 202.56 0.010 14.93 0.2 116.3 Vel = 4.60 6.357 1T 101.14 116.5 116.5 A8 C=120 37.72 0.0 0.0 202.56 0.001 138.86 0.2 116.5 Vel = 2.07 6.357 2E 44.79 116.7 116.7 A9 C=120 35.21 8.2 0.0 202.56 0.001 79.99 0.1 116.7 Vel = 2.07 8.458 1E 113.62 125.1 125.1 A10 C=140 1F 45.89 0.0 0.0 202.56 0.000 159.51 0.0 125.1 Vel = 1.16 W 202.56 125.1 K = 18.11 PATH 2 FROM HYDRAULIC REFERENCE 307 TO B2 19.35 1.049 1E 6.00 11.9 11.9 K = 5.60 307S C=120 2.00 -2.6 0.0 19.35 0.122 8.00 1.0 11.9 Vel = 7.25 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) 0 a 0 Element By Westin Drawing Date:l-14-19 6/ 6/19 Tyco Fire Products 10:18 Page 7 HYD. Qa DIA. FITTING PIPE Pt Pt 0 REF "C" TYPES FTNG'S Pe Pv ******* NOTES ******* POINT Qt Pf/ft TOTAL Pf Pn PATH 2 FROM HYDRAULIC REFERENCE 307 TO B2 CONTINUED 1.049 1T 1.14 10.3 10.3 EqK = 6.03 307 0=120 5.00 0.0 0.0 19.35 0.122 6.14 0.8 10.3 Vel = 7.25 619 1.442 C=120 19.35 0.026 12.00 11.1 11.1 0.00 0.0 0.0 12.00 0.3 11.1 Vel = 3.84 19.57 1.442 1T 618 C=120 38.91 0.095 11.85 11.4 11.4 7.43 0.0 0.0 See PATH 4 19.28 1.8 11.4 Vel = 7.72 B2 38.91 13.2 K = 10.71 PATH 3 FROM HYDRAULIC REFERENCE 310 TO 616 19.50 1.049 1E 6.00 12.1 12.1 K = 5.60 310S 0=120 2.00 -2.6 0.0 0 19.50 0.124 8.00 1.0 12.1 Vel = 7.31 1.049 1T 1.14 10.5 10.5 EqK = 6.01 310 0=120 5.00 0.0 0.0 19.50 0.124 6.14 0.8 10.5 Vel = 7.31 616 19.50 11.3 K = 5.81 PATH 4 FROM HYDRAULIC REFERENCE 308 TO 618 19.57 1.049 1E 6.00 12.2 12.2 K = 5.60 308S 0=120 2.00 -2.6 0.0 19.57 0.125 8.00 1.0 12.2 Vel = 7.33 1.049 1T 1.14 10.6 10.6 EqK = 6.01 308 0=120 5.00 0.0 0.0 19.57 0.125 6.14 0.8 10.6 Vel = 7.33 UNITS - DIAMETER (INCH) LENGTH (FOOT) 0 FLOW (GPM) PRESSURE (PSI) Element By Westin Drawing Date:1-14-19 6/ 6/19 10:18 Tyco Fire Products Page 8 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv ******* NOTES ******* POINT Qt Pf/ft TOTAL Pf Pn 618 19.57 11.4 K = 5.80 PATH 5 FROM HYDRAULIC REFERENCE 305 TO B3 19.64 1.049 1E 6.00 12.3 12.3 K = 5.60 305S 0=120 2.00 -2.6 0.0 19.64 0.126 8.00 1.0 12.3 Vel = 7.36 1.049 1T 305 C=120 19.64 0.126 1.14 10.7 10.7 EqK = 6.00 5.00 0.0 0.0 6.14 0.8 10.7 Vel = 7.36 1.442 12.00 11.5 11.5 621 0=120 0.00 0.0 0.0 19.64 0.027 12.00 0.3 11.5 Vel = 3.90 19.87 1.442 1T 11.85 11.8 11.8 620 C=120 7.43 0.0 0.0 See PATH 6 39.51 0.097 19.28 1.9 11.8 Vel = 7.84 B3 39.51 13.7 K = 10.68 PATH 6 FROM HYDRAULIC REFERENCE 306 TO 620 19.87 1.049 1E 6.00 12.6 12.6 K = 5.60 306S 0=120 2.00 -2.6 0.0 19.87 0.129 8.00 1.0 12.6 Vel = 7.45 1.049 1T 1.14 11.0 11.0 EqK = 5.99 306 0=120 5.00 0.0 0.0 19.87 0.129 6.14 0.8 11.0 Vel = 7.45 620 19.87 11.8 K = 5.78 PATH 7 FROM HYDRAULIC REFERENCE 303 TO B4 20.14 1.049 1E 6.00 12.9 12.9 K = 5.60 303S 0=120 2.00 -2.6 0.0 20.14 0.132 8.00 1.0 12.9 Vel = 7.55 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) Element By Westin Drawing Date:1-14-19 6/ 6/19 Tyco Fire Products 10:18 Page 9 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv ******* NOTES ******* POINT Qt Pf/ft TOTAL Pf Pn PATH 7 FROM HYDRAULIC REFERENCE 303 TO B4 CONTINUED 1.049 1T 1.14 11.4 11.4 EqK = 5.97 303 0=120 5.00 0.0 0.0 20.14 0.132 6.14 0.8 11.4 Vel = 7.55 1.442 12.00 12.2 12.2 623 0=120 0.00 0.0 0.0 20.14 0.028 12.00 0.3 12.2 Vel = 4.00 20.37 1.442 1T 622 C=120 40.51 0.102 11.85 12.5 12.5 7.43 0.0 0.0 See PATH 8 19.28 2.0 12.5 Vel = 8.04 B4 40.51 14.5 K = 10.64 PATH 8 FROM HYDRAULIC REFERENCE 304 TO 622 20.37 1.049 1E 6.00 13.2 13.2 K = 5.60 304S 0=120 2.00 -2.6 0.0 0 20.37 0.135 8.00 1.1 13.2 Vel = 7.64 1.049 1T 1.14 11.7 11.7 EqK = 5.95 304 0=120 5.00 0.0 0.0 20.37 0.135 6.14 0.8 11.7 Vel = 7.64 622 20.37 12.5 K = 5.75 PATH 9 FROM HYDRAULIC REFERENCE 301 TO B5 22.28 1.049 1T 1.00 15.8 15.8 K = 5.60 301 0=120 5.00 0.0 0.0 22.28 0.159 6.00 1.0 15.8 Vel = 8.35 625 1.442 C=120 22.28 0.034 12.90 16.8 16.8 0.00 0.0 0.0 12.90 0.4 16.8 Vel = 4.42 UNITS - DIAMETER (INCH) LENGTH (FOOT) a FLOW (GPM) PRESSURE (PSI) Element By Westin Drawing Date:1-14-19 6/ 6/19 10:18 Tyco Fire Products Page 10 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv ******* NOTES ******* POINT Qt Pf/ft TOTAL Pf Pn PATH 9 FROM HYDRAULIC REFERENCE 301 TO B5 CONTINUED 22.57 1.442 1T 12.06 17.2 17.2 624 C=120 7.43 0.0 0.0 See PATH 10 44.85 0.123 19.49 2.4 17.2 Vel = 8.90 B5 44.85 19.6 K = 10.13 PATH 10 FROM HYDRAULIC REFERENCE 302 TO 624 22.57 1.049 1T 1.00 16.2 16.2 K = 5.60 302 C=120 5.00 0.0 0.0 22.57 0.163 6.00 1.0 16.2 Vel = 8.46 624 22.57 17.2 K = 5.44 PATH 11 FROM HYDRAULIC REFERENCE B6 TO B7 74.86 2.157 2E 106.89 22.2 22.2 B6 C=120 2T 36.92 0.0 0.0 See PATH 1 74.86 0.045 143.81 6.4 22.2 Vel = 6.64 B7 74.86 28.6 K = 13.99 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) m 3 rnrn 0 0 0— < N • ao y > o0 -a E E o m� -3WinHQ • O. O. CO 250 gpm hose a co coCD Cco s! N r O O O O u) O O 0. a M 3 0 LL O O O LO N O O N O LO O O Element By Westin 0 Job Name: Location: Drawing Date: Contractor: Drawing Date:1-14-19 6/ 6/19 10:18 HYDRAULIC DESIGN INFORMATION SHEET Element By Westin 515 Industry Drive Tukwila, WA 99188 1-14-19 Total Fire Protection 1004 7th Ave. North Brandon, SD 57005 Designer: Greg Lindholm Calculated By:SprinkCAD www.sprinkcad.com 451 N. Cannon Ave. Lansdale, PA 19446 Construction: Reviewing Authorities: Remote Area Number: 4 Telephone:605-582-2400 Occupancy: SYSTEM DESIGN Code:NFPA 13 Hazard:Ord. Grp. 1 System Type:WET Area of Sprinkler Oper. Density (gpm/sq ft) Area per Sprinkler Hose Allowance Inside Hose Allowance Outside 1138 sq ftl 0.150 1 130.0 sq ftl 0 gpm 1 250 gpm 1 Sprinkler or Nozzle Make: Viking Model: VK302 K -Factor: 5.60 Temperature Rating: 155 CALCULATION SUMMARY em Required: 481.8 WATER SUPPLY 11 Flowing Outlets psi Required: 123.1 @ Source Water Flow Test Date of Test 12-17-18 Static Pressure 150.0 psi Residual Pres 125.0 psi At a Flow of 8001 gpm Elevation 0" Pump Data Rated Capacity Rated Pressure Elevation Make: Model: 0 gpm 0.0 psi 0 Location: Source of Information: Tukwila Public Works SYSTEM VOLUME 1422 Gallons Notes: 0 Element By Westin Drawing Date:1-14-19 6/ 6/19 10:18 HYDRAULIC CALCULATION DETAILS QTY DESCRIPTION HYDRAULIC FLOW LOSS LENGTH C ID gpm psi TOTALS Hydr Ref W Required at Hyd Area 4 232 118.3 psi 1 3" Grvd Butterfly Valve Tyco BFV- 9' 120 3.068 232 0.6 1 3" Grvd Check Valve Tyco CV-1FR CHART LOSS 232 0.9 1 4" Grvd Butterfly Valve Tyco BFV- 5' 120 4.026 232 0.1 1 6" Grvd Butterfly Valve Tyco BFV- 11' 120 6.065 232 0.0 1 8" Flngd Back Flow Valve Deringe CHART LOSS 232 5.8 Fixed Flow Flow Loss 250 gpm Elevation Change -6'0" -2.6 Hydr Ref R1 Required at Source 482 123.1 psi Water Source150.0 psi static,125.0 psi residual @ 8001 gpm 482 gpm 149.9 psi SAFETY PRESSURE 26.8 psi Available Pressure of 149.9 psi Exceeds Required Pressure of 123.1 psi This is a safety margin of 26.8 psi or 18 % of Supply Maximum Water Velocity is 20.6 fps 0 Element By Westin Drawing Date:1-14-19 6/ 6/19 10:18 Page 3 FITTING NAME TABLE ABBREV. NAME C Coupling E 90' Standard Elbow F 45' Elbow S Straight Flow Thru Tee T 90' Flow Thru Tee ✓ Valve LEGEND HYD REF Hydraulic reference. Refer to accompanying flow diagram. _ K FACTOR Flow factor for open head or path where Flow (gpm) = K x -\/P Qa Flow added or subtracted Qt Total flow DIA Actual internal diameter of pipe C Hazen Williams pipe roughness factor Pf/ft Friction loss per foot of pipe PIPE Length of pipe FTNG'S Number of fittings. See table above. TOTAL Total length (PIPE + FTNG'S) Pt Total pressure (psi) at fitting Pe Pressure due to change in elevation where Pe = 0.433 x change in elevation Friction loss (psi) to fitting where Pf = 1 x 4.52 x (Q/C)^1.85 / ID^4.87 Pv Velocity pressure (psi) where Pv = 0.001123 x QA2/IDA4 Pn Normal pressure (psi), where Pn = Pt - Pv NOTES: - Pressures are balanced to 0.01 psi. Pressures are listed to 0.1 psi. Addition may vary by 0.1 psi due to accumulation of round off. - Calculations conform to NFPA 13. - Velocity Pressures are not considered in these Calculations Element By Westin Drawing Date:1-14-19 6/ 6/19 10:18 Page 4 NODE ELEVATION SPRINKLER PRESSURE ACTUAL MINIMUM ACTUAL NUMBER K -FACTOR FLOW FLOW DENSITY (FT) (GPM/(PSI^'-1)) (PSI) (GPM) (GPM) (GPM/SQ.FT) 401 14.00 402 14.00 403 14.00 404 14.00 405 14.00 406 14.00 407 14.00 408 14.00 409 14.00 410 14.00 411 14.00 A7 13.00 A8 13.00 A9 13.00 A10 -6.00 B6 14.00 B7 14.00 B8 14.00 B9 14.00 B10 14.00 C1 14.00 C2 14.00 C3 14.00 G1 14.00 w -6.00 5.60 5.60 5.60 5.60 5.60 5.60 5.60 5.60 5.60 5.60 5.60 12.1 12.4 13.3 15.4 12.5 12.8 13.8 16.0 15.3 15.7 16.9 109.4 109.6 109.9 118.3 29.1 29.1 29.1 47.8 104.4 19.0 19.6 21.9 108.8 118.3 19.5 19.7 20.5 22.0 19.8 20.0 20.8 22.4 21.9 22.2 23.0 Max velocity of 20.55 occurs in the pipe from B8 TO C3 19.5 19.5 19.5 19.5 19.5 19.5 19.5 19.5 19.5 19.5 19.5 0.15 0.15 0.16 0.17 0.15 0.15 0.16 0.17 0.17 0.17 0.18 0 0 Element By Westin Drawing Date:1-14-19 6/ 6/19 Tyco Fire Products 10:18 Page 5 HYD. Qa DIA. FITTING PIPE Pt Pt 0 REF "C" TYPES FTNG'S Pe Pv ******* NOTES ******* POINT Qt Pf/ft TOTAL Pf Pn PATH 1 FROM HYDRAULIC REFERENCE 401 TO W (PRIMARY PATH) 401 19.50 1.442 C=120 19.50 0.026 10.00 12.1 12.1 K = 5.60 0.00 0.0 0.0 10.00 0.3 12.1 Vel = 3.87 19.71 1.442 10.00 12.4 12.4 K = 5.60 402 0=120 0.00 0.0 0.0 39.21 0.096 10.00 1.0 12.4 Vel = 7.78 20.46 1.442 10.00 13.3 13.3 K = 5.60 403 0=120 0.00 0.0 0.0 59.67 0.209 10.00 2.1 13.3 Vel = 11.84 22.00 1.442 1T 2.06 15.4 15.4 K = 5.60 404 0=120 7.43 0.0 0.0 81.67 0.373 9.49 3.5 15.4 Vel = 16.20 01 2.157 12.00 19.0 19.0 C=120 0.00 0.0 0.0 81.67 0.052 12.00 0.6 19.0 Vel = 7.24 0 C2 83.05 2.157 C=120 164.72 0.192 12.00 19.6 19.6 0.00 0.0 0.0 See PATH 2 12.00 2.3 19.6 Vel = 14.60 67.09 2.157 1T 7.59 21.9 21.9 C3 C=120 12.31 0.0 0.0 See PATH 3 231.81 0.362 19.90 7.2 21.9 Vel = 20.55 2.157 1T 39.27 29.1 29.1 B8 C=120 12.31 0.0 0.0 231.81 0.362 51.57 18.7 29.1 Vel = 20.55 2.157 lE 138.26 47.8 47.8 B9 0=120 1T 18.46 0.0 0.0 231.81 0.362 156.72 56.7 47.8 Vel = 20.55 2.635 1E 7.30 104.4 104.4 B10 0=120 1T 24.71 0.0 0.0 231.81 0.136 32.01 4.4 104.4 Vel = 13.77 G1 4.260 1E C=120 231.81 0.013 1.00 108.8 108.8 13.17 0.4 0.0 14.17 0.2 108.8 Vel = 5.27 UNITS - DIAMETER (INCH) LENGTH (FOOT) 0 FLOW (GPM) PRESSURE (PSI) Element By Westin Drawing Date:1-14-19 6/ 6/19 Tyco Fire Products 10:18 Page 6 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv ******* NOTES ******* POINT Qt Pf/ft TOTAL Pf Pn PATH 1 FROM HYDRAULIC REFERENCE 401 TO W (PRIMARY PATH) 4.260 1E 1.76 109.4 109.4 A7 C=120 13.17 0.0 0.0 231.81 0.013 14.93 0.2 109.4 Vel = 5.27 6.357 1T 101.14 109.6 109.6 A8 C=120 37.72 0.0 0.0 231.81 0.002 138.86 0.3 109.6 Vel = 2.37 6.357 2E 44.79 109.9 109.9 A9 C=120 35.21 8.2 0.0 231.81 0.002 79.99 0.1 109.9 Vel = 2.37 8.488 1E 113.62 118.3 118.3 A10 C=140 1F 45.89 0.0 0.0 231.81 0.000 159.51 0.1 118.3 Vel = 1.33 W 231.81 118.3 K = 21.31 PATH 2 FROM HYDRAULIC REFERENCE 405 TO C2 405 19.83 1.442 C=120 19.83 0.027 10.00 12.5 12.5 K = 5.60 0.00 0,0 0.0 10.00 0..3 12.5 Vel = 3.93 20.04 1.442 10.00 12„8 12.8 K = 5.60 406 C=120 0.00 0,0 0.0 39.88 0.099 10.00 1„0 12.8 Vel = 7.91 407 20.80 1.442 C=120 60.68 0.215 10.00 13„8 13.8 K = 5.60 0.00 0„0 0.0 10.00 2,2 13.8 Vel = 12.04 22.37 1.442 1T 408 C=120 83.05 0.385 2.06 16.0 16.0 K = 5.60 7.43 0.0 0.0 9.49 3.7 16.0 Vel = 16.48 C2 83.05 19.6 K = 18.75 PATH 3 FROM HYDRAULIC REFERENCE 409 TO C3 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) 0 0 Element By Westin Drawing Date:1-14-19 6/ 6/19 Tyco Fire Products 10:18 Page 7 HYD. Qa DIA. FITTING PIPE Pt Pt OREF "C" TYPES FTNG'S Pe Pv ******* NOTES ******* POINT Qt Pf/ft TOTAL Pf Pn PATH 3 FROM HYDRAULIC REFERENCE 409 TO C3 CONTINUED 409 21.93 1.442 C=120 21.93 0.033 10.00 15.3 15.3 K = 5.60 0.00 0.0 0.0 10.00 0.3 15.3 Vel = 4.35 22.17 1.442 10.00 15.7 15.7 K = 5.60 410 C=120 0.00 0.0 0.0 44.10 0.119 10.00 1.2 15.7 Vel = 8.75 22.99 1.442 1T 12.06 16.9 16.9 K = 5.60 411 C=120 7.43 0.0 0.0 67.09 0.259 19.49 5.1 16.9 Vel = 13.31 C3 67.09 21.9 K = 14.33 0 UNITS - DIAMETER (INCH) LENGTH (FOOT) 0 FLOW (GPM) PRESSURE (PSI) 3rnrn °0—o < N w n 2 EO E E ._ ._ o aaw CO arnrnaa �NNaOt� Nc corn N • 4) N r as x.223 ai CO tomb 3cnwo_1 (1) CO foo a c v ei a; N = 0 a E�nY E o nwin1-X 0 CO 0 N 0 0 N 0 CC) acn- 0 N 0 OD 0 • gpm hose >. a a c Q -c w 0 CO 0 N 0 0 N 0 CC) acn- 0 N 0 OD 0 Element By Westin 0 Job Name: Location: Drawing Date: Contractor: Drawing Date:1-14-19 6/ 6/19 10:19 HYDRAULIC DESIGN INFORMATION SHEET Element By Westin 515 Industry Drive Tukwila, WA 99188 1-14-19 Total Fire Protection 1004 7th Ave. North Brandon, SD 57005 Designer: Greg Lindholm Calculated By:SprinkCAD www.sprinkcad.com 451 N. Cannon Ave. Lansdale, PA 19446 Construction: Reviewing Authorities: Remote Area Number: 5 Telephone:605-582-2400 Occupancy: SYSTEM DESIGN Code:NFPA 13 Hazard:Ord. Grp. I System Type:WET Area of Sprinkler Oper. Density (gpm/sq ft) Area per Sprinkler Hose Allowance Inside Hose Allowance Outside 933 sq ftl 0.150 1 130.0 sq ft) 0 gpm 1 250 gpm 1 Sprinkler or Nozzle Make: Viking Model: VK302 K -Factor: 5.60 Temperature Rating: 155 CALCULATION SUMMARY ityom Required: 547.1 psi 15 Flowing Outlets Required: 133.5 @ Source WATER SUPPLY Water Flow Test Date of Test Static Pressure Residual Pres At a Flow of Elevation 12-17-18 150.0 psi 125.0 psi 8001 gpm 0" Pump Data Rated Capacity 0 gpm Rated Pressure 0.0 psi Elevation 0 Make: Model: Location: Source of Information: Tukwila Public Works SYSTEM VOLUME 1422 Gallons Notes: tx- Element By Westin Drawing Date:1-14-19 6/ 6/19 10:19 HYDRAULIC CALCULATION DETAILS QTY DESCRIPTION HYDRAULIC FLOW LOSS LENGTH C ID gpm psi TOTALS Hydr Ref W Required at Hyd Area 5 297 127.6 psi Hydr Ref W Required at Hyd Area 5 338 99.7 psi Hydr Ref W Required at Hyd Area 5 338 99.7 psi Hydr Ref W Required at Hyd Area 5 338 99.7 psi Hydr Ref W Required at Hyd Area 5 338 99.7 psi 1 3" Grvd Butterfly Valve Tyco BFV- 9' 120 3.068 297 0.9 1 3" Grvd Check Valve Tyco CV-1FR CHART LOSS 297 1.1 1 4" Grvd Butterfly Valve Tyco BFV- 5' 120 4.026 297 0.1 1 6" Grvd Butterfly Valve Tyco BFV- 11' 120 6.065 297 0.0 1 8" Flngd Back Flow Valve Deringe CHART LOSS 297 6.2 Fixed Flow Flow Loss 250 gpm Elevation Change -6'0" -2.6 Hydr Ref R1 Required at Source 547 133.5 psi Water Source150.0 psi static,125.0 psi residual @ 8001 gpm 547 gpm 149.8 psi SAFETY PRESSURE 16.4 psi Available Pressure of 149.8 psi Exceeds Required Pressure of 133.5 psi This is a safety margin of 16.4 psi or 11 % of Supply Maximum Water Velocity is 26.3 fps 0 0 Element By Westin Drawing Date:1-14-19 6/ 6/19 10:19 Page 3 HYD REF K FACTOR Qa Qt DIA C Pf/ft PIPE FTNG'S TOTAL Pt Pe c> Pv Pn NOTES: c ABBREV. FITTING NAME TABLE NAME C Coupling E 90' Standard Elbow F 45' Elbow S Straight Flow Thru Tee T 90' Flow Thru Tee ✓ Valve LEGEND Hydraulic reference. Refer to accompanying flow diagram. _ Flow factor for open head or path where Flow (gpm) = K x -\/P Flow added or subtracted Total flow Actual internal diameter of pipe Hazen Williams pipe roughness factor Friction loss per foot of pipe Length of pipe Number of fittings. See table above. Total length (PIPE + FTNG'S) Total pressure (psi) at fitting Pressure due to change in elevation where Pe = 0.433 x change in elevation Friction loss (psi) to fitting where Pf = 1 x 4.52 x (Q/C)^1.85 / ID^4.87 Velocity pressure (psi) where Pv = 0.001123 x Q^2/ID^4 Normal pressure (psi), where Pn = Pt - Pv - Pressures are balanced to 0.01 psi. Pressures are listed to 0.1 psi. Addition may vary by 0.1 psi due to accumulation of round off. - Calculations conform to NFPA 13. - Velocity Pressures are not considered in these Calculations Element By Westin Drawing Date:1-14-19 6/ 6/19 10:19 Page 4 NODE ELEVATION SPRINKLER PRESSURE ACTUAL MINIMUM ACTUAL NUMBER K -FACTOR FLOW FLOW DENSITY (FT) (GPM/(PSI^'1)) (PSI) (GPM) (GPM) (GPM/SQ.FT) 501 14.00 501S 8.00 502 14.00 5025 8.00 503 14.00 5035 8.00 504 14.00 5045 8.00 505 14.00 5055 8.00 506 14.00 5065 8.00 507 14.00 5075 8.00 508 14.00 508S 8.00 509 14.00 5095 8.00 510 14.00 5105 8.00 511 14.00 511S 8.00 512 14.00 512S 8.00 513 14.00 513S 8.00 514 14.00 514S 8.00 515 14.00 515S 8.00 626 14.00 627 14.00 628 14.00 629 14.00 630 14.00 631 14.00 632 14.00 633 14.00 634 14.00 635 14.00 636 14.00 A7 13.00 A8 13.00 A9 13.00 A10 -6.00 B6 14.00 B7 14.00 B8 14.00 B9 14.00 B10 14.00 El 14.00 5.60 5.60 5.60 5.60 5.60 5.60 5.60 5.60 5.60 5.60 5.60 5.60 5.60 5.60 5.60 13.8 15.2 12.5 13.9 11.7 13.2 11.4 13.0 11.5 13.0 11.1 12.7 10.8 12.4 10.3 11.9 10.9 12.5 10.9 12.1 11.7 12.8 9.5 11.2 9.3 11.0 10.3 11.6 9.8 11.5 10.5 10.2 10.0 11.0 11.9 11.6 12.3 13.3 12.5 12.2 14.7 118.3 118.6 119.1 127.5 21.0 21.0 21.0 21.0 110.7 11.2 21.8 20.9 20.4 20.2 20.2 19.9 19.7 19.3 19.8 19.5 20.1 18.7 18.6 19.1 19.0 19.5 19.5 19.5 19.5 19.5 18.0 15.0 18.0 18.0 19.5 19.5 18.0 14.8 14.8 14.8 0.17 0.16 0.16 0.16 0.16 0.17 0.20 0.16 0.17 0.15 0.15 0.16 0.23 0.31 0.22 Element By Westin Drawing Date:1-14-19 6/ 6/19 10:19 Page 5 NODE ELEVATION SPRINKLER PRESSURE ACTUAL MINIMUM ACTUAL 04UMBER K -FACTOR FLOW FLOW DENSITY (FT) (GPM/(PSI^;1)) (PSI) (GPM) (GPM) (GPM/SQ.FT) E2 14.00 11.3 E3 14.00 11.3 E4 14.00 11.6 E5 14.00 11.7 E6 14.00 12.1 E7 14.00 12.7 E8 14.00 15.2 G1 14.00 117.6 W -6.00 127.6 Max velocity of 26.34 occurs in the pipe from E8 TO B9 Nodes with "S" indicate a node at the top of a sprig or bottom of drop pendent. The node without an "S" is on the branch. 0 Element By Westin Drawing Date:1-14-19 6/ 6/19 10:19 Tyco Fire Products Page 6 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv ******* NOTES ******* POINT Qt Pf/ft TOTAL Pf Pn PATH 1 FROM HYDRAULIC REFERENCE 513 TO W (PRIMARY PATH) 513S 18.57 1.049 1E C=120 18.57 0.113 6.00 11.0 11.0 K = 5.60 2.00 -2.6 0.0 8.00 0.9 11.0 Vel = 6.96 1.049 1T 1.17 9.3 9.3 EqK = 6.09 513 0=120 5.00 0.0 0.0 18.57 0.113 6.17 0.7 9.3 Vel = 6.96 628 1.442 C=120 18.57 0.024 8.00 10.0 10.0 0.00 0.0 0.0 8.00 0.2 10.0 Vel = 3.68 18.72 1.442 1T 5.21 10.2 10.2 627 C=120 7.43 0.0 0.0 See PATH 2 37.29 0.087 12.65 1.1 10.2 Vel = 7.40 38.04 2.157 0.21 11.3 11.3 E2 C=120 0.00 0.0 0.0 See PATH 3 75.33 0.045 0.21 0.0 11.3 Vel = 6.68 19.50 2.157 3.45 11.3 11.3 E3 C=120 0.00 0.0 0.0 See PATH 7 94.83 0.069 3.45 0.2 11.3 Vel = 8.41 19.32 2.157 1.17 11.6 11.6 E4 C=120 0.00 0.0 0.0 See PATH 4 114.15 0.098 1.17 0.1 11.6 Vel = 10.12 19.81 2.157 3.39 11.7 11.7 E5 C=120 0.00 0.0 0.0 See PATH 8 133.96 0.131 3.39 0.4 11.7 Vel = 11.88 20.06 2.157 3.61 12.1 12.1 E6 0=120 0.00 0.0 0.0 See PATH 12 154.01 0.170 3.61 0.6 12.1 Vel = 13.65 59.83 2.157 8.00 12.7 12.7 E7 C=120 0.00 0.0 0.0 See PATH 6 AND 11 213.85 0.312 8.00 2.5 12.7 Vel = 18.96 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) 0 0 0 Element By Westin Drawing Date:1-14-19 6/ 6/19 Tyco Fire Products 10:19 Page 7 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv ******* NOTES ******* POINT Qt Pf/ft TOTAL Pf Pn PATH 1 FROM HYDRAULIC REFERENCE 513 TO W (PRIMARY PATH) 83.24 2.157 10.09 15.2 15.2 E8 C=120 0.00 0.0 0.0 See PATH 10 AND 15 297.08 0.572 10.09 5.8 15.2 Vel = 26.34 2.157 1E 138.26 21.0 21.0 B9 C=120 1T 18.46 0.0 0.0 297.08 0.572 156.72 89.7 21.0 Vel = 26.34 2.635 1E 7.30 110.7 110.7 B10 C=120 1T 24.71 0.0 0.0 297.08 0.216 32.01 6.9 110.7 Vel = 17.65 G1 4.260 1E C=120 297.08 0.021 1.00 117.6 117.6 13.17 0.4 0.0 14.17 0.3 117.6 Vel = 6.75 4.260 1E 1.76 118.3 118.3 A7 C=120 13.17 0.0 0.0 297.08 0.021 14.93 0.3 118.3 Vel = 6.75 0 A8 6.357 1T 101.14 118.6 118.6 C=120 37.72 0.0 0.0 297.08 0.003 138.86 0.4 118.6 Vel = 3.03 6.357 2E 44.79 119.1 119.1 A9 C=120 35.21 8.2 0.0 297.08 0.003 79.99 0.2 119.1 Vel = 3.03 8.488 1E 113.62 127.5 127.5 A10 C=140 1F 45.89 0.0 0.0 297.08 0.001 159.51 0.1 127.5 Vel = 1.70 w 297.08 127.6 K = 26.30 PATH 2 FROM HYDRAULIC REFERENCE 512 TO 627 18.72 1.049 1E 6.00 11.2 11.2 K = 5.60 512S C=120 2.00 -2.6 0.0 18.72 0.115 8.00 0.9 11.2 Vel = 7.02 UNITS - DIAMETER (INCH) LENGTH (FOOT) 0 FLOW (GPM) PRESSURE (PSI) Element By Westin Drawing Date:1-14-19 6/ 6/19 10:19 Tyco Fire Products Page 8 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv ******* NOTES ******* POINT Qt Pf/ft TOTAL Pf Pn PATH 2 FROM HYDRAULIC REFERENCE 512 TO 627 CONTINUED 1.049 1T 512 C=120 18.72 0.115 1.17 9.5 9.5 EqK = 6.08 5.00 0.0 0.0 6.17 0.7 9.5 Vel = 7.02 627 18.72 10.2 K = 5.86 PATH 3 FROM HYDRAULIC REFERENCE 515 TO E2 18.98 1.049 lE 6.00 11.5 11.5 K = 5.60 515S 0=120 2.00 -2.6 0.0 18.98 0.118 8.00 0.9 11.5 Vel = 7.12 1.049 1T 0.65 9.8 9.8 EqK = 6.05 515 0=120 5.00 0.0 0.0 18.98 0.118 5.65 0.7 9.8 Vel = 7.12 19.06 1.442 1T 0.79 10.5 10.5 626 C=120 7.43 0.0 0.0 See PATH 5 38.04 0.091 8.22 0.7 10.5 Vel = 7.55 El 2.157 4.52 11.2 11.2 C=120 0.00 0.0 0.0 38.04 0.013 4.52 0.1 11.2 Vel = 3.37 E2 38.04 11.3 K = 11.31 PATH 4 FROM HYDRAULIC REFERENCE 508 TO E4 19.32 1.049 lE 6.00 11.9 11.9 K = 5.60 508S C=120 2.00 -2.6 0.0 19.32 0.122 8.00 1.0 11.9 Vel = 7.24 1.049 1T 1.17 10.3 10.3 EqK = 6.03 508 0=120 5.00 0.0 0.0 19.32 0.122 6.17 0.8 10.3 Vel = 7.24 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) 0 Element By Westin Drawing Date:1-14-19 6/ 6/19 Tyco Fire Products 10:19 Page 9 HYD. Qa DIA. FITTING PIPE Pt Pt IDREF "C" TYPES FTNG'S Pe Pv ******* NOTES ******* POINT Qt Pf/ft TOTAL Pf Pn PATH 4 FROM HYDRAULIC REFERENCE 508 TO E4 CONTINUED 1.442 1T 13.02 11.0 11.0 629 0=120 7.43 0.0 0.0 19.32 0.026 20.45 0.5 11.0 Vel = 3.83 E4 19.32 11.6 K = 5.68 PATH 5 FROM HYDRAULIC REFERENCE 514 TO 626 514S 19.06 1.049 1T C=120 19.06 0.119 6.00 11.6 11.6 K = 5.60 5.00 -2.6 0.0 11.00 1.3 11.6 Vel = 7.14 514 1.442 C=120 19.06 0.025 8.59 10.3 10.3 EqK = 5.94 0.00 0.0 0.0 8.59 0.2 10.3 Vel = 3.78 4:, 626 19.06 10.5 K = 5.88 PATH 6 FROM HYDRAULIC REFERENCE 507 TO E7 507S 19.70 1.049 lE C=120 19.70 0.127 6.00 12.4 12.4 K = 5.60 2.00 -2.6 0.0 8.00 1.0 12.4 Vel = 7.38 1.049 1T 507 C=120 19.70 0.127 1.83 10.8 10.8 EqK = 6.00 5.00 0.0 0.0 6.83 0.9 10.8 Vel = 7.38 631 1.442 C=120 19.70 0.027 8.76 11.6 11.6 0.00 0.0 0.0 8.76 0.2 11.6 Vel = 3.91 19.93 1.442 1T 1.21 11.9 11.9 630 C=120 7.43 0.0 0.0 See PATH 9 39.63 0.098 8.65 0.8 11.9 Vel = 7.86 UNITS - DIAMETER (INCH) LENGTH (FOOT) 0 FLOW (GPM) PRESSURE (PSI) Element By Westin Drawing Date:1-14-19 6/ 6/19 10:19 Tyco Fire Products Page 10 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv ******* NOTES ******* POINT Qt Pf/ft TOTAL Pf Pn E7 39.63 12.7 K = 11.11 PATH 7 FROM HYDRAULIC REFERENCE 510 TO E3 19.50 1.049 1T 6.00 12.1 12.1 K = 5.60 510S 0=120 5.00 -2.6 0.0 19.50 0.124 11.00 1.4 12.1 Vel = 7.31 1.442 1T 510 C=120 19.50 0.026 8.79 10.9 10.9 EqK = 5.91 7.43 0.0 0.0 16.22 0.4 10.9 Vel = 3.87 E3 19.50 11.3 K = 5.80 PATH 8 FROM HYDRAULIC REFERENCE 509 TO E5 19.81 1.049 1E 6.00 12.5 12.5 K = 5.60 509S 0=120 2.00 -2.6 0.0 19.81 0.128 8.00 1.0 12.5 Vel = 7.42 1.049 1T 0.79 10.9 10.9 EqK = 5.99 509 0=120 5.00 0.0 0.0 19.81 0.128 5.79 0.7 10.9 Vel = 7.42 E5 19.81 11.7 K = 5.80 PATH 9 FROM HYDRAULIC REFERENCE 506 TO 630 506S 19.93 1.049 1E C=120 19.93 0.129 6.00 12.7 12.7 K = 5.60 2.00 -2.6 0.0 8.00 1.0 12.7 Vel = 7.47 1.049 1T 1.00 11.1 11.1 EqK = 5.98 506 0=120 5.00 0.0 0.0 19.93 0.129 6.00 0.8 11.1 Vel = 7.47 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) 0 0 0 Element By Westin Drawing Date:1-14-19 6/ 6/19 10:19 Tyco Fire Products Page 11 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv ******* NOTES ******* POINT Qt Pf/ft TOTAL Pf Pn 630 19.93 11.9 K = 5.78 PATH 10 FROM HYDRAULIC REFERENCE 504 TO E8 504S 20.17 1.049 1E C=120 20.17 0.132 6.00 13.0 13.0 K = 5.60 2.00 -2.6 0.0 8.00 1.1 13.0 Vel = 7.56 1.049 1T 504 C=120 20.17 0.132 1.00 11.4 11.4 EqK = 5.97 5.00 0.0 0.0 6.00 0.8 11.4 Vel = 7.56 635 1.442 C=120 20.17 0.028 10.00 12.2 12.2 0.00 0.0 0.0 10.00 0.3 12.2 Vel = 4.00 634 20.36 1.442 C=120 40.53 0.102 8.00 12.5 12.5 0.00 0.0 0.0 See PATH 13 8.00 0.8 12.5 Vel = 8.04 633 20.91 1.442 1T C=120 61.43 0.220 1.21 13.3 13.3 7.43 0.0 0.0 See PATH 14 8.65 1.9 13.3 Vel = 12.19 E8 61.43 15.2 K = 15.75 PATH 11 FROM HYDRAULIC REFERENCE 505 TO E7 505S 20.20 1.049 1E C=120 20.20 0.133 6.00 13.0 13.0 K = 5.60 2.00 -2.6 0.0 8.00 1.1 13.0 Vel = 7.57 1.049 1T 1.00 11.5 11.5 EqK = 5.96 505 C=120 5.00 0.0 0.0 20.20 0.133 6.00 0.8 11.5 Vel = 7.57 1.442 1T 632 C=120 20.20 0.028 8.79 12.3 12.3 7.43 0.0 0.0 16.22 0.5 12.3 Vel = 4.01 UNITS - DIAMETER (INCH) LENGTH (FOOT) 0 FLOW (GPM) PRESSURE (PSI) Element By Westin Drawing Date:1-14-19 6/ 6/19 10:19 Tyco Fire Products Page 12 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv ******* NOTES ******* POINT Qt Pf/ft TOTAL Pf Pn E7 20.20 12.7 K = 5.66 PATH 12 FROM HYDRAULIC REFERENCE 511 TO E6 20.06 1.049 1T 6.00 12.8 12.8 K = 5.60 511S C=120 5.00 -2.6 0.0 20.06 0.131 11.00 1.4 12.8 Vel = 7.52 1.442 1T 8.79 11.7 11.7 EqK = 5.87 511 C=120 7.43 0.0 0.0 20.06 0.028 16.22 0.5 11.7 Vel = 3.98 E6 20.06 12„1 K = 5.76 PATH 13 FROM HYDRAULIC REFERENCE 503 TO 634 20.36 1.049 1E 6.00 13.2 13.2 K = 5.60 503S C=120 2.00 -2.6 0.0 20.36 0.134 8.00 1.1 13.2 Vel = 7.63 1.049 1T 503 C=120 20.36 0.134 1.00 11.7 11.7 EqK = 5.95 5.00 0.0 0.0 6.00 0.8 11.7 Vel = 7.63 634 20.36 12.5 K = 5.76 PATH 14 FROM HYDRAULIC REFERENCE 502 TO 633 20.91 1.049 1E 6.00 13.9 13.9 K = 5.60 502S C=120 2.00 -2.6 0.0 20.91 0.141 8.00 1.1 13.9 Vel = 7.84 1.049 1T 1.00 12.5 12.5 EqK = 5.92 502 C=120 5.00 0.0 0.0 20.91 0.141 6.00 0.8 12.5 Vel = 7.84 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) v 0 0 Element By Westin Drawing Date:1-14-19 6/ 6/19 10:19 Tyco Fire Products Page 13 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv ******* NOTES ******* POINT Qt Pf/ft TOTAL Pf Pn 633 20.91 13.3 K = 5.73 PATH 15 FROM HYDRAULIC REFERENCE 501 TO E8 21.80 1.049 1E 6.00 15.2 15.2 K = 5.60 501S 0=120 2.00 -2.6 0.0 21.80 0.153 8.00 1.2 15.2 Vel = 8.17 1.049 1T 501 C=120 21.80 0.153 1.00 13.8 13.8 EqK = 5.87 5.00 0.0 0.0 6.00 0.9 13.8 Vel = 8.17 1.442 1T 8.79 14.7 14.7 636 0=120 7.43 0.0 0.0 21.80 0.032 16.22 0.5 14.7 Vel = 4.33 E8 21.80 15.2 K = 5.59 0 UNITS - DIAMETER (INCH) LENGTH (FOOT) 0 FLOW (GPM) PRESSURE (PSI) 0 3rnrn oo0— < N O x50 N) 0. 0. (n V) 0. 0) 0) 0. 0 V el CV If) vi N N o•3oaa w- r > aa)) m >.>.c�coovCL CD CO CO N N 0- 0- 0. 0. 0) 0) 00) o co N 3 C0 of a) N C — O .12 EE O r- 7 a) —� LU CL O 0 N O N 0 O N av)— O N O CO 0 • •3 W Spm hose O ID N 11 co O 0 N O N 0 O N av)— O N O CO 0 Element By Westin 0 Job Name: Location: _Drawing Date: Contractor: Drawing Date:1-14-19 6/ 6/19 10:20 HYDRAULIC DESIGN INFORMATION SHEET Element By Westin 515 Industry Drive Tukwila, WA 99188 1-14-19 Total Fire Protection 1004 7th Ave. North Brandon, SD 57005 Designer: Greg Lindholm Calculated By:SprinkCAD www.sprinkcad.com 451 N. Cannon Ave. Lansdale, PA 19446 Construction: Reviewing Authorities: Remote Area Number: 6 Telephone:605-582-2400 Occupancy: SYSTEM DESIGN Code:NFPA 14 Hazard:Standpipe System Type:WET Area of Sprinkler Oper. Density (gpm/sq ft) Area per Sprinkler Hose Allowance Inside Hose Allowance Outside 750 sq ftl 1.000 250.0 sq ftl 0 gpm 1 0 gpm I Sprinkler or Nozzle Make: KENEDY Model: HOSE K-Factor:25.00 Temperature Rating: 0 CALCULATION SUMMARY 3 Flowing Outlets Cr Required: 766.7 psi Required: 137.0 @ Source WATER SUPPLY Water Flow Test Date of Test 12-17-18 Static Pressure 150.0 psi Residual Pres 125.0 psi At a Flow of 8001 gpm Elevation 0" Pump Data Rated Capacity 0 gpm Rated Pressure 0.0 psi Elevation 0 Make: Model: Location: Source of Information: Tukwila Public Works SYSTEM VOLUME 1422 Gallons Notes: Element By Westin Drawing Date:1-14-19 6/ 6/19 10:20 HYDRAULIC CALCULATION DETAILS QTY DESCRIPTION HYDRAULIC FLOW LOSS LENGTH C ID gpm psi TOTALS Hydr Ref W Required at Hyd Area 6 767 138.2 psi 2 4" Grvd Butterfly Valve Tyco BFV- 9' 120 4.026 767 1.4 Elevation Change -6'0" -2.6 Hydr Ref R1 Required at Source 767 137.0 psi Water Source150.0 psi static,125.0 psi residual @ 8001 gpm 767 gpm 149.7 psi SAFETY PRESSURE 12.7 psi Available Pressure of 149.7 psi Exceeds Required Pressure of 137.0 psi This is a safety margin of 12.7 psi or 8 % of Supply Maximum Water Velocity is 17.7 fps 0 Element By Westin Drawing Date:1-14-19 6/ 6/19 10:20 Page 3 HYD REF K FACTOR Qa Qt DIA C Pf/ft PIPE FTNG'S TOTAL Pt Pe 0 Pv Pn NOTES: ei ABBREV. FITTING NAME TABLE NAME C Coupling E 90' Standard Elbow F 45' Elbow S Straight Flow Thru Tee T 90' Flow Thru Tee ✓ Valve LEGEND Hydraulic reference. Refer to accompanying flow diagram. _ Flow factor for open head or path where Flow (gpm) = K x -\/P Flow added or subtracted Total flow Actual internal diameter of pipe Hazen Williams pipe roughness factor Friction loss per foot of pipe Length of pipe Number of fittings. See table above. Total length (PIPE + FTNG'S) Total pressure (psi) at fitting Pressure due to change in elevation where Pe = 0.433 x change in elevation Friction loss (psi) to fitting where Pf = 1 x 4.52 x (Q/C)^1.85 / ID^4.87 Velocity pressure (psi) where Pv = 0.001123 x Q^2/ID^4 Normal pressure (psi), where Pn = Pt - Pv - Pressures are balanced to 0.01 psi. Pressures are listed to 0.1 psi. Addition may vary by 0.1 psi due to accumulation of round off. - Calculations conform to NFPA 13. - Velocity Pressures are not considered in these Calculations Element By Westin Drawing Date:1-14-19 6/ 6/19 10:20 Page 4 NODE ELEVATION SPRINKLER PRESSURE ACTUAL MINIMUM ACTUAL NUMBER K -FACTOR FLOW FLOW DENSITY (FT) (GPM/(PSI^'-1)) (PSI) (GPM) (GPM) (GPM/SQ.FT) 601 59.00 25.00 100.0 250.0 250.0 1.00 602 47.92 25.00 103.6 254.5 250.0 1.02 603 47.92 25.00 110.0 262.2 250.0 1.05 A6 44.33 113.2 A7 13.00 127.5 A8 13.00 127.8 A9 13.00 128.1 A10 -6.00 137.7 B6 14.00 126.8 B7 14.00 126.8 B8 14.00 126.8 B9 14.00 126.8 B10 14.00 126.8 D1 59.00 101.4 D2 47.92 106.4 D3 13.00 125.0 F1 47.92 111.6 G1 14.00 126.8 W -6.00 138.2 Max velocity of 17.74 occurs in the pipe from 603 TO Fl 0 0 Element By Westin Drawing Date:1-14-19 6/ 6/19 Tyco Fire Products 10:20 Page 5 HYD. Qa DIA. FITTING PIPE Pt Pt IDREF "C" TYPES FTNG'S Pe Pv ******* NOTES ******* POINT Qt Pf/ft TOTAL Pf Pn PATH 1 FROM HYDRAULIC REFERENCE 602 TO W (PRIMARY PATH) 254.46 2.469 1T 602 C=120 254.46 0.223 0.50 103.6 103.6 K = 25.00 12.00 0.0 0.0 12.50 2.8 103.6 Vel = 17.22 250.00 4.260 2E 36.91 106.4 106.4 D2 C=120 26.33 15.1 0.0 See PATH 2 504.45 0.055 63.24 3.5 106.4 Vel = 11.47 6.357 5E 259.96 125.0 125.0 D3 C=120 1T 125.73 0.0 0.0 504.45 0.008 385.70 3.0 125.0 Vel = 5.15 262.24 6.357 2E 44.79 128.1 128.1 A9 C=120 35.21 8.2 0.0 See PATH 3 766.69 0.017 79.99 1.4 128.1 Vel = 7.83 8.488 1E 113.62 137.7 137.7 A10 C=140 1F 45.89 0.0 0.0 766.69 0.003 159.51 0.5 137.7 Vel = 4.39 766.69 138.2 K = 65.22 PATH 2 FROM HYDRAULIC REFERENCE 601 TO D2 250.00 2.469 lE 601 C=120 250.00 0.215 0.50 100.0 100.0 K = 25.00 6.00 0.0 0.0 6.50 1.4 100.0 Vel = 16.92 D1 4.260 C=120 250.00 0.015 11.08 101.4 101.4 0.00 4.8 0.0 11.08 0.2 101.4 Vel = 5.68 D2 250.00 106.4 K = 24.24 PATH 3 FROM HYDRAULIC REFERENCE 603 TO A9 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) Element By Westin Drawing Date:1-14-19 6/ 6/19 10:20 Tyco Fire Products Page 6 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv ******* NOTES ******* POINT Qt Pf/ft TOTAL Pf Pn PATH 3 FROM HYDRAULIC REFERENCE 603 TO A9 CONTINUED 262.24 2.469 1E 603 C=120 262.24 0.235 0.50 110.0 110.0 K = 25.00 6.00 0.0 0.0 6.50 1.5 110.0 Vel = 17.74 F1 4.260 3.58 111.6 111.6 C=120 0.00 1.6 0.0 262.24 0.017 3.58 0.1 111.6 Vel = 5.96 4.260 30.33 113.2 113.2 A6 C=120 0.00 13.1 0.0 262.24 0.017 30.33 0.5 113.2 Vel = 5.96 G1 4.260 1E C=120 262.24 0.017 1.00 126.8 126.8 13.17 0.4 0.0 14.17 0.2 126.8 Vel = 5.96 4.260 1E 1.76 127.5 127.5 A7 C=120 13.17 0.0 0.0 262.24 0.017 14.93 0.2 127.5 Vel = 5.96 6.357 1T 101.14 127.8 127.8 A8 C=120 37.72 0.0 0.0 262.24 0.002 138.86 0.3 127.8 Vel = 2.68 A9 262.24 128.1 K = 23.17 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) 0 innovation • Engineering • alM • Eabtication A iltifiat.a0/ Tim= Contractor Speatin 0 1 Contractor: TOTAL FIRE PROTECTION Project: ELEMENT BY WESTIN WA • 16 17 12 13 14 15 SEISMIC ATTACHMENT DETAILS LOC KIT I.D. BRACED UTILITY BRACEWEIGHT UTILITY WEIGHT BRACE UTILITY -1" 15% PER NFPA BRACE ORIENTATION ATTACHMENT TYPE MAX. HANGER SPACING BASED ON TRIBUTARY LENGTH MAX. BRACE SPACING SEISMIC INSTALLATION DETAIL MIN ROD DIA. BRACE ARM ELEMENT HORIZONTAL ACCELERATION MAX. SEISMIC BRACE REACTION MAX. BRACE REACTION FROM FP TRIBUTARY LENGTH CUMULATIVE MAX BRACE REACTION ROE) DEAD LOAD (Itts) 5 X ROD DEAD LOAD -1- 250 LBS PER NEPA (s) 1A6 MIN BRACE ARM DECK ANCHORAGE MIN BRACE ANCHORAGE DETAIL Single Hung Pipe Rer°, to FG 2' Pipe 4.93 5.67 T (1 -WAY) 10' 20' B1.0.1P 3f3- 1-1/4" Sch. 40 Steel Pipe 0.65g 104# 392# 496# 57# 537# CONNECTION TO Z PURLIN D5.2 FG -L 2" Pipe 4_93 5.67 L (1 -WAY) 10' 40' B1_0_1P 3/8 1-1/4" Sch_ 40 Steel Pipe 0..65g 208# 283# 491# 57# 537# CONNECTION TO Z PURLIN D5_Z FH 2" Pipe 4.93 5.67 T/L (2 -WAY) 10' 40' 61.8.1P 3/8" 1-1/4" Sch. 40 Steel Pipe 0.65g 208# 283# 491# 57# 537# CONNECTION TO Z PURLIN D51 FK 3" Pipe 8.60 9.89 T (1 -WAY) 7 10' 30' B1.0_1P 3/8" 1-1/4" Sch. 40 Steel Pipe 0_65g 273# 220# 493# 100# 751# CONNECTION TO Z PURUN 052 FK -L 3" Pipe 8.60 9.89 L (1 -WAY) 10' 30' B1.0.1P 3/8" 1-1/4" Sch. 40 Steel Pipe 0.65g 273# 220# 493# 100# 751# CONNECTION TO Z PURLIN D5.2 FL 3" Pipe 8_60 9_89 T/L (2 -WAY) 7 10' 30' BI .8_1P 3/8" 1-1/4" Sch_ 40 Steel Pipe 0_65g 273# 220# 493# 100# 751# CONNECTION TO Z PURLIN 051 FM 4" Pipe 14.31 16.46 T (1 -WAY) 10' 32' B1.0.IP 5/8" 1-1/4" Sch. 40 Steel Pipe 0.65g 484# 0# 484# 167# 1084# CONNECTION TO Z PURLIN D5.Z FN 4" Pipe 14.31 16.46 Tit (2 -WAY) 10' 32' Bl_ 8_ 1P 5/8' 1-1/4" Sch_ 40 Steel Pipe 0_65g 484# 0# 484# 167# 1084# CONNECTION TO Z PURLIN D5_Z FQ 6" Pipe 26.02 r 29.92 T (1 -WAY) T 18' B1.0.1P 1/2" 1-1/4" Sch. 40 Steel Pipe 0.65g 495# 0# 495# 212# 1312# CONNECTION TO Z PURLIN 052 FQ-L 6" Pipe 26.02 ' 29.92 L (1 -WAY) 7' 18' B1_0_1P 1/2" 1-1/4" Sch_ 40 Steel Pipe 0.65g 495# 0# 495# 212# 1312 CONNECTION TO Z PURUN D5_2 FR 6" Pipe 26.02 29_92 TR_ (2 -WAY) 7' 18" 61.8.1P 1/2" 1-1/4" Sch_ 40 Steel Pipe 0.65g 495# 0# 495# 212# 1312# CONNECTION TO Z PURLIN 05.2 UNLESS OTHERWISE INDICATED, THE SCOPE OF THE ATTACHED DESIGN IS UMITED TO THE SEIS4vIIC RESTRAINT OF THE HORIZONTAL RUNS OF THE SUSPENDED SERVICES AS LISTED IN THE ACCOMPANYING ISAT SEISMIC RESTRAINT LEGEND_ REFER TO BRACING NOTES ON SHEET 6/12/2019 Zone of Influence / TributaryCale it 1 ;Kit ID=FG Sprinkler Sytem Load Calculation (Fp,,=CpWp) C- P 0.65 Diameter Type Total length (ft) Weight/ft Weight 1 1/2 Sch. 10 125 2.97 371.25 207.90 (5.64) 1A6 (0. ,66) steseit.t......._* 3/8' thick Rer°, to SCH 40 Pipe ..13:1,;1°25514') :11E14'''''''200011 st Source Drawing: Subtotal Weight 371.25 1 Wp Incl. (15%) 426.94 Total (F .a.) 277.51 Tributary Brace Reaction 392.40 - - 1 - - - - Zone of Influence/Tributary Calc#2 Kit ID= FG -L& FH Sprinkler Sytem Load Calculation (F ,= CWp) r C= 0.65 Diameter Type Total length (ft) Weight/ft Weight 1 1/2 Sch. 10 90 2.97 257.30 207.90 1070 (4.75) PHD 12 Gases 4.9"-50r 1440 (640) Strut Channel 1001 & 1201 W.1"-74° 1740 Source Drawing: Subtotal Weight 267.30 207.90 Wp Incl. (15%) 307.40 Total (FT") 199.81 Tributary Brace Reaction 282.53 1 Zone of Influence/Tributary Calett3 1Kit ID=FK Sprinkler Sytem Load Calculation I P - (F a = CpWp) MATERIAL: Ductile Iron and Low Carbon Steel INSTALL: Insert brace element into fitting against back of jaw. Tighten set screw finger tight, then tighten until hex head breaks off. Adjust attachment to proper brace angle and mount to structure. Diameter Type Total length (ft) Weight/ft Weight 11/2 Sch. 10 70 2.97 207.90 (5.64) 1A6 (0. ,66) steseit.t......._* 3/8' thick Rer°, to SCH 40 Pipe ..13:1,;1°25514') :11E14'''''''200011 st 0 Source Drawing: Subtotal Weight 207.90 s.ieser.S5udu.a.... Wp Incl. (15%) 23 . 9 Total (F . 155.41 Tributary Brace Reaction 219.74 Zone of Influence/Tributary Cale # 4 Kit ID= FK -L & FL Sprinkler Sytem Load Calculation (Fpw =CWp) Cp= 0.65 Diameter Type Total length (ft) Weight/ft Weight 11/2 Sch. 10 70 2.97 207.90 1070 (4.75) PHD 12 Gases 4.9"-50r 1440 (640) Strut Channel 1001 & 1201 W.1"-74° 1740 (7.73) Source Drawing: Subtotal Weight 207.90 (8.62) Wp Incl. (15%) 239.09 Total (F .} 155.41 Tributary Brace Reaction 219.74 FROM STRUCTURAL INFO NOTES: The design of the vertical supports and their anchorage to structure is not included in this submittal. Sway bracing of branch lines shall be addressed by others. 2. EARTHQUAKE DESIGN DATA: a SEISMIC IMPORTANCE FACTOR - 1.0 b. SPECTRAL. RESPONSE COEFFICIENTS : G. SITE CLASS: E d. SPECTRAL- RESPONSE COEFFICIENTS: S(PS) 0.565; s(, 1) - 0.858 e. SEISMIC. DESIGN CATEGORY: 5(5) • 1.4420; 5(1) • 0.56.34 FROM NFPA 9.3.5.9.3 The horizontal force, Fp,„, acting on the brace shall be taken as Fp,„ = Cp147p, where is the seismic coefficient selected in Table 9.3.5.9.3 utilizing the short period response parameter, S. Table 9.3.5.9.3 Seismic Coefficient Table 0.33 or less 0.4 0.5 0.6 0.7 0.8 0.9 1 1.1 1.2 1.3 0.35 0.38 0.4 0.42 0.42 0.44 0.48 0.51 0.54 0.57 0.61 1.4 0.65 1.5 1.6 1.7 1.8 1.9 2 2.1 0.7 0.75 0.79 0.84 0.89 0.93 0.98 2.2 2.3 2.4 2.6 2.7 2.8 2.9 3 3.1 3.2 3.6 3.7 3.8 3.9 4 1.07 1.12 1.17 1.21 1.26 1.4 1.45 1.49 1.54 1.59 1.63 1.68 1.73 1.77 1.82 1.87 CLEVlS HANGER, PAGE H3.3 FOR BRACE SPACING, RIGID BRACE ASSEMBLY, THREADED SUPPORT ROD AND DECK ANCHORAGE REQUIREMENTS SEE AT PROJECT LEGEND PHD FIG 030 & 031 COMPONENTS MTH INTEGRAL 'SHEAR -OFF HEX HEAD I NU' TRANSVERSE BRACE FOR BRACE SPACING, RIGID BRACE ASSEMBLY, THREADED SUPPORT ROD AND DECK ANCHORAGE REQUIREMENTS SEE ISAT PROJECT LEGEND TRANSVERSE BRACE 1 CLEVE HANGal, PAM H33 LONGITUDINAL BRACE OVERHEAD VIEW OVERHEAD VIEW PHD FIG. 030, C -CLAMP STRUCTURAL ATTACHMENT. TIGHTEN SET SCREW TIL HEX HEAD SHEARS OFF. 45° NOM. TRANSVERSE BRACE SCH. 40 STEEL PIPE, PAGE EID OR PHD 1001SERIES STRUT, PACE El E. (MAY BE INSTALLED 180' OPPOSITE AS NEEDED) CLEVE HANGER (BEYOND) PAGE H3.3 THREADED ROD, PAGE H1. S I NG REQUIREMENTS, PAGE 01. TRANSVERSE BRACE SCH. 40 STEEL PPE, PAGE ED OR P1101001 SERES STRUT, PAGE El E. (MAY BE INSTALLED 187 OPPOSITE) PIPE PHD FIG. 030, C -CLAMP STRUCTURAL ATTACHMENT, TYP (2) TIGHTEN SET SCREW ILL HEX HEAD SHEARS CFF. FUNCTION: Designed for bracing pipe against sway and seismic disturbances. Universal swivel design allows for attachment at any surface angle combined with concentric loading. Structure attachment fitting designed to use r thru 2' SCH 40 pipe, structural steel, and PHD 12 gauge strut channel (1001 dr 1201) as sway bracing elements. No bracing member thicker than 3/£2 can be used in conjunction with this product Utilize the Fig. 030 with a PHD Manufacturing pipe attachment fitting and a bracing element to form a complete sway brace assembly. Sway brace assemblies are intended to be installed in accordance with NFPA 13 and the manufacturer's installation instructions. SIZE: ur mounting hole. Braces up to 8" PipeMAX FINISH: Electro -galvanized MATERIAL: Ductile Iron and Low Carbon Steel INSTALL: Insert brace element into fitting against back of jaw. Tighten set screw finger tight, then tighten until hex head breaks off. Adjust attachment to proper brace angle and mount to structure. APPROVALS: Underwriters Laboratories listed for LYS and Canada. Factory Mutual approved. Listed for use with NFPA fastener tables and PHD sway brace components only ORDERING: Specify figure number 45' NOM. CLEVIS HANGER, PAGE H3.3. LONGITUDINAL BRACE 501. 40 STEEL PIPE, PAGE EID OR PHD 1001 SERIES STRUT, PAGE Et E. UL Desi'mt4aa$ to a* fokrti &i.ar'''°'**A""thiles(UP Member Me,nber: ildeEness MeiobarLetigOt lb. 145 Brace member Ea' B.so 1- Thrs 2. P'1". SC1122HG.40... 30* -44' 1270 (5.64) 1A6 (0. ,66) steseit.t......._* 3/8' thick Rer°, to SCH 40 Pipe ..13:1,;1°25514') :11E14'''''''200011 st 0 s.0,,, 2015 (8.95) s.ieser.S5udu.a.... 2740 se.Refer.chctoh.:NdaFpFseiselPAA.1133 202020111555 (8.95)(803.-9956)) TIGHTEN HEX NUT TILL IT SHEARS OFF TYR/ PHD FIG. 031, CLAMPING PIPE ATTACHMENT. INSTALL VATHIN 24'0F SUPPORT HANGER. 2' DIA. THRU 8' DIA. PIPE (STEEL, COPPER, CAST PON) PHD FE. 031 , BRACE PPE ATTACHMENT. NSTALL WITHIN 240F SUPPORT HANGER. TIGHTEN HEX NUTS TILL THEY SHEAR OFF. a 24' 24' MAX MAX SIDE VIEW PHD FIG. 031, CLAMPING PPE ATTACHMENT. LOCATE ITHIN 24OF HANGER. TIGHTEN SET SCREW TILL HEX HEAD SHEARS OFF. 2' DIA. THRU IPDIA.PITE (STEEL, COPPER, CAST IRON) SINGLE HUNG PIPE 1 -WAY TRANSVERSE RIGID BRACE PHD FIG. 030 & 031 FM APPROVED COMPONENTS A Division of TomorsoControctor Specialties International &drank Application Technology 14848 Northam Stroud La mhos. CA 90638 877-099-4726 (Tel Free) 714-523-0845 (fax) vomv.isatsb.com SINGLE HUNG PIPE WITH CLEVIS HANGER 2 -WAY TRANSVERSE - LONGITUDINAL RIGID BRACING PHD FIG. 030 & 031 FM APPROVED COMPONENTS REV -3 05118/16 Page B1.0.1P A Division of Tamara, Commie. Specialties Intematbnal Seim* Applca'don Technology 14848 Northam Street, La Mirada, CA 90638 677-999-4728 (Tol Free) 714-523-0845 (tax) www.leateb.wm REV -1 05119/16 Page B1.8.IP aection of loadpe,pendiaikzrto buildfrigstruciorre FM Mwdm,ze Design Load For Itraeltit$0810.4419FlowPirw FINISH: Electro -galvanized MATERIAL: Ductile Iron and Low Carbon Steel, Grade 5 damping bolts =Angle. ertIcal APPROVALS: Underwriters Laboratories listed for US and Canada Factory Mutual approved. Listed for use with PHD sway brace components only ORDERING: Specify figure number and sprinkler pipe size Brace member tOertreet tbs. Ate Member Length lbs. 30* -44' 1270 (5.64) .1..rhf. 2. (GE1/3091. 45.-59- 2040 18.07) SCH 40 Pipe ..13:1,;1°25514') 62-74" 2423 (1009) See Cheri Below 2015 75* -93' 2740 (12.18) See Chart Below 30* -44" 900 (4.05) I/4 Tn. 319' Thick 45'59" 1280 (5.69) 2",,,,n0 Steel 69'-74. 1570 (698) 2900 75•-5f 1750 (7.78) 30'-44' 30* -44. 1070 (4.75) PHD 12 Gases 4.9"-50r 1440 (640) Strut Channel 1001 & 1201 W.1"-74° 1740 (7.73) 75,90' 75-90° 1840 (8.62) FUNCTION: Designed for bracing pipe against sway and seisnuc disturbance Versatile design allows for attachment at any angle and the ability lobe used in a lateral or longitudinal bracing configuration. The pipe attachment component of a sway brace system used in conjunction with a PHD Manufacturing structural attachment fitting and joined together with a bracing element form a complete sway brace assembly. Sway brace assemblies are intended to be installed in accordance with NFPA 13 and the manufacturer's installation instructions. SIZE Pipe sizes 2 Urn 8". Can use 2 thru 2' SCH 40 pipe, structural steel, and PHD 12 gauge strut channel (1001 dr 1201) as sway bracing elements. FINISH: Electro -galvanized MATERIAL: Ductile Iron and Low Carbon Steel, Grade 5 damping bolts INSTALL: Place attachment around pipe to be braced, positioning brace attachment as needed, then tighten damping bolts and nuts finger tight Insert brace component into fitting against back of jaw. Tighten set screw finger tight, adjust brace angle as needed, then tighten set screw until hex head breaks off. Then evenly torque damping bolts until het portion of damping nuts break off. APPROVALS: Underwriters Laboratories listed for US and Canada Factory Mutual approved. Listed for use with PHD sway brace components only ORDERING: Specify figure number and sprinkler pipe size tA. Maolmuet 08918.9 Loads ..... Alt P8181188es,„1113.180&40 1(2 SCH 40 only) Sracelingle FtWOVORICat 113611009 In Member era lbs. 105 Snow Meader 'lldctaesa Member Length lbs. SN 1' Thea 2" Pipe SCH 40 Rater to NFPA13 2015 (8.98) Structural Steel 114' & 342 thick Refer to NFPA13 2415(890) 0.199 1001 Series Strut 12 Ga. See Cheri Below 2015 (8.96) 1201 Series Strut 12 Ga. See Chart Below 2015 (8.96) Fig. 031 CLAMPING PIPE ATTACHMENT Strut Flg.# there: 1' Mill 7.$0340Ptivit 1CINT36111.1041921514.04.19034541 P1W Strut 0190044 Matdmum Horlaontui Load 00' From VertIcal Sracelingle FtWOVORICat 113611009 In r era lbs. 105 250 380 2 lateral mm 1370 (suit Max lbs. 149 Max lbs. 1114 Max tb. 1114 1001 0.199 (48011 75,92 58' (1473.2) 4670 128771 1161(29484) 1165 (618) 1741(44196) 518 (2,30) 1201 0.033 (0238) 38 196521 18001(8451 76 1(1906.0) 495 (2.16) 112 (28448) 218 (0.97) Unless °atomise specified, dmensions en drawings end in charts are in inches and dimensions shown in parentheses are in maimeters. PM MasImurn 014446 Lood there: 1' Mill 7.$0340Ptivit 1CINT36111.1041921514.04.19034541 nut Sky SCM 10,40 &PlowPlpe Sracelingle FtWOVORICat 113611009 Strut Fg.k Slice Member Direetton lbs. Igt lbs. kg 2 lateral 3cr-44' 1370 (suit 260 (1.18) 49'.59' 1930 (828) (53) 60,74. 2370 (10.54) 75,92 2810 (12491 21/2 ,., 30,44" 1500 (6.67) 2.77 (126) 45,52 2120 (943) 6,,°' 612-74. 2800 (1(59) 75,92 2900 (12.89) 33.00 (6.40) 30'-44' 1370 (8.09) 75,90' (1.38) 45,59' 1930 (8.511) 63°) 60'-74' 2370 (1054) 75,90' 2810 (12.49) 3 35 32-44' 1370 (8.09) 113 (1.42) 49'-59' 1930 (858) 31/2 PC° 80,74' 2370 (10.64) 75,92 2810 (12.49) 4 30,44' 1370 (8.09) (.1.50) 45,59" 1930 (8.58) C103) 93,74. 2370 ((0.54) 8,, 75,92 2910 ((2.49) 6 (126) 30,44' 1370 (6.09) 4.57 (2.07) 45"-52 1930 (8.581 e0'.74. 2370 ((024) 75,90° 2810 ((2.49) 8 30.44' 1410 (827) „A6) ' 45,59' 2000 (8.89) ((66) 60,74' 2450 (10.89) 5.42 75'-90' 2730 (12.(4) 8 , (2°°' 30* -44' 1320 (527) r.,..86) '- 45,59' 1870 (231) so. -74. 2290 (10.18) 8.52 75,90° 2550 (1(34) Unless otherwise specified, all dimensions on drawings and in charts ere in inches end dmensions shown in parentheses are in managers PM Maxt,ttum Dub:steed Skeet - itier- INIERNATICaVAL APOUCA a ........ Project Name: Location: ISAT Project APPROVED BY: PittiStret Criarittril fautkeurefteezrairal Leadee•From Witted Strut Fg.k Slice Member Direetton Angle fDeg,eesl Ills. 149 1' Thru 2' 3CH 413 P'''' (GB/730W, • EN10255H, cc JI933454) lateral 30'-44* 1170 (5.64) 45,52 2040 (007) 80,74' 2450 (10.89) 75,92 2740 (12.18) 1/4' Tien 3/8' Tiidc Struchsral Steel Lateral & L°^94.F.41 30,44" 900 (4.00) 48'ol2 1280 (5.69) 60,74* 1570 (6.98) 75,90" 1750 (7.78) ."- RID 12 Gauge Strut Channel 1001 & 1201 Lateral & Lonflfier11841 30"-44° 1070 (4.75) 45,52 1440 (6.40) 60,74. 1740 (7.73) 75,90' 1940 (8ez) PIPE ATTACHMENT 11/05/2019 Unless otherwise specified, all dimensions co drawings and in charts we in inches and dmensions shown et parentheses we in mffimaters. PHD Manufacturing, Inc. PHD Manufacturing, Inc. ROOFING BY OTHERS EH/3 A307 THRU BOLT TO MATCH BRACKETS HOLE DIAMETER ISAT GENERAL NOTES INTERNATIONAL SEISMIC APPLICATION TECHNOLOGY a Division of ',mon= Contractor Spedskirs BLOCKING BY OTHERS Z PURLIN BY OTHERS MAX BRACE LOAD = 500 LBS (ENGINEER OF RECORD TO CONFIRM SUITABILITY OF STRUCTURE TO ACCOMMODATE THE LOADS) DESIGN AND DETAILING OF BLOCKING REQUIRED FOR STRUCTURAL STABILITY AND TIES TO HORIZONTAL DIAPHRAGM ARE TO BE BY THE STRUCTURAL ENGINEER OF RECORD SEISMIC BRACE TO Z PURLIN CONNECTION International Seismk Appketion Technology 14848 Northam Street, La Mirada, CA 90638 877-999-4728 (Tol Free) 714-523-0845 (fax) www.isatsb.com 1. All Seismic Bracing shall be installed in accordance with the ' NFPA 13' 2. Brace all mains and cross mains regardless of size and branch lines and other piping 2-1/2' and greater. 3. See ISAT 'F' Details for rigid brace arm members. a)7'-0" Max for 1' Diam. Sch. 40 Steel Pipe b) 3-0' Max(o 1-114' Diem. Sch. 40 Steel Pipe 4. Brace forces calculated in the ISAT Bracing Legend are for an inclination angle of 45 degrees from horizontal. 5. Rigid brace aims can be rotated 180 degrees from true transverse or longitudinal. 6. Transverse Brace arms must be perpendicular to the Pipe run (on either side of the ATR) and spaced no more than 40 feet Longitudinal Brace arms must be parallel to the Pipe run (on either side of the ATR) and spaced no more than 80 feet 7. Transverse braces may act as longitudinal braces as long as they are placed within 24 inches of the joint and are 2-1/2' or larger pipe. 8. The distance from the last brace to the end of the run shall not exceed 6 feet and the last longitudinal brace to the end of the pipe shall not exceed 40 feet. 9. Braces are to be placed within 24 inches of a flexible coupling. 10. Seismic Bracing can be moved to the next hanger in either direction from the designated location as long as the maximum brace spacing is not exceeded. See ISAT SEISMIC RESTRAINT LEGEND for maximum brace spacing. 11. Verification of the adequacy of the structural and architectural components is by others. 12. All Existing Utilities are Outside !SATs Scope of Work 13. If Seismic Bracing is NOT Shown, then one of the following conditions exist for the entire length of the run: a)The Rod Hangers are less than 6' from the the top of the Utility or Component to the Bottom of the Structure.(Longitudinal Braces are required when the distance to the structure is less than 6'- NFPA 9.3.5.3.7) b) The length of the run is lessthan 12. 14. Kit ID 7X -L' designates a Transverse Brace used for Longitudinal Restraint 15. The Registered Professional Engineer Stamp that appears on the drawings Apples ONLY to the Approval of ISAT Seismic Bracing Associated with the Utilities Shown and Delineated in the Seismic Restraint Legend. 16. The Seismic Design Shown on these drawings is in Conformance with the Project's Seismic Specification and Building Code. Modification to the Design and / or Layout may be required due to field conditions. 17. Seisnic Bracing for Suspended Equipment will be addressed in a separate submittal. 18. Rod dead load includes an allowance for pipe fittings estimated as the pipe weight times 1.15 (NFPA 9.3.5.6.1). An additional 250 pound load (NFPA 9.1.1.2) is also included but is not used for the seismic bracing calculations. Rev. 0 10/13/17 Page D52 - itier- INIERNATICaVAL APOUCA a ........ Project Name: Location: ISAT Project APPROVED BY: PittiStret Criarittril fautkeurefteezrairal Leadee•From Witted Strut Fg.k DATE: 10/7/2019 r Or= 100 200 250 Note: The following Seismic Criteria was obtained from the structural portion of the project documents. Information not provided in the project documents has been derived from the code sections or tables noted below. Design spectral response acceleration (5% Damped) at short periods (ASCE 7-10, Section 1t4A) Ste = 0.97 Component Importance Factor (ASCE 7-10, Section 13.1.3) to = 1.50 Average Roof Height of Structure Relative to the Base Elevation h = 56.00 Factors vary depending on the utility service and materials of construction. See Table 3 below for values. Component Amplification Factor (ASCE 7-10, Table 13.6-1) 8,, = See Table 3 Component Response Modification Factor (ASCE 7-10, Table 13.6-1) R0 = See Table 3 Seismic Design Category (ASCE 7-10, Table 11.6-1) Seismic Design category = D 1455 lbs. (di Mao lbs. 814 Man lbs. 614 1001 0.189 (4801) Level 58' (1473.2) 4670 (20.77) 116' (29484) 1165 (5.19) 174" (4419.6) 518 (2.30) 1201 0.033 (0.838) 38' (965.2) 1900 (8.45) 72 (1905.0) 485 (2.16) 112 (2844.8) 218 (0.97) 11/05/2019 Unless otherwise specified, all dimensions co drawings and in charts we in inches and dmensions shown et parentheses we in mffimaters. PHD Manufacturing, Inc. PHD Manufacturing, Inc. ROOFING BY OTHERS EH/3 A307 THRU BOLT TO MATCH BRACKETS HOLE DIAMETER ISAT GENERAL NOTES INTERNATIONAL SEISMIC APPLICATION TECHNOLOGY a Division of ',mon= Contractor Spedskirs BLOCKING BY OTHERS Z PURLIN BY OTHERS MAX BRACE LOAD = 500 LBS (ENGINEER OF RECORD TO CONFIRM SUITABILITY OF STRUCTURE TO ACCOMMODATE THE LOADS) DESIGN AND DETAILING OF BLOCKING REQUIRED FOR STRUCTURAL STABILITY AND TIES TO HORIZONTAL DIAPHRAGM ARE TO BE BY THE STRUCTURAL ENGINEER OF RECORD SEISMIC BRACE TO Z PURLIN CONNECTION International Seismk Appketion Technology 14848 Northam Street, La Mirada, CA 90638 877-999-4728 (Tol Free) 714-523-0845 (fax) www.isatsb.com 1. All Seismic Bracing shall be installed in accordance with the ' NFPA 13' 2. Brace all mains and cross mains regardless of size and branch lines and other piping 2-1/2' and greater. 3. See ISAT 'F' Details for rigid brace arm members. a)7'-0" Max for 1' Diam. Sch. 40 Steel Pipe b) 3-0' Max(o 1-114' Diem. Sch. 40 Steel Pipe 4. Brace forces calculated in the ISAT Bracing Legend are for an inclination angle of 45 degrees from horizontal. 5. Rigid brace aims can be rotated 180 degrees from true transverse or longitudinal. 6. Transverse Brace arms must be perpendicular to the Pipe run (on either side of the ATR) and spaced no more than 40 feet Longitudinal Brace arms must be parallel to the Pipe run (on either side of the ATR) and spaced no more than 80 feet 7. Transverse braces may act as longitudinal braces as long as they are placed within 24 inches of the joint and are 2-1/2' or larger pipe. 8. The distance from the last brace to the end of the run shall not exceed 6 feet and the last longitudinal brace to the end of the pipe shall not exceed 40 feet. 9. Braces are to be placed within 24 inches of a flexible coupling. 10. Seismic Bracing can be moved to the next hanger in either direction from the designated location as long as the maximum brace spacing is not exceeded. See ISAT SEISMIC RESTRAINT LEGEND for maximum brace spacing. 11. Verification of the adequacy of the structural and architectural components is by others. 12. All Existing Utilities are Outside !SATs Scope of Work 13. If Seismic Bracing is NOT Shown, then one of the following conditions exist for the entire length of the run: a)The Rod Hangers are less than 6' from the the top of the Utility or Component to the Bottom of the Structure.(Longitudinal Braces are required when the distance to the structure is less than 6'- NFPA 9.3.5.3.7) b) The length of the run is lessthan 12. 14. Kit ID 7X -L' designates a Transverse Brace used for Longitudinal Restraint 15. The Registered Professional Engineer Stamp that appears on the drawings Apples ONLY to the Approval of ISAT Seismic Bracing Associated with the Utilities Shown and Delineated in the Seismic Restraint Legend. 16. The Seismic Design Shown on these drawings is in Conformance with the Project's Seismic Specification and Building Code. Modification to the Design and / or Layout may be required due to field conditions. 17. Seisnic Bracing for Suspended Equipment will be addressed in a separate submittal. 18. Rod dead load includes an allowance for pipe fittings estimated as the pipe weight times 1.15 (NFPA 9.3.5.6.1). An additional 250 pound load (NFPA 9.1.1.2) is also included but is not used for the seismic bracing calculations. Rev. 0 10/13/17 Page D52 A Division of Tomarco Contractor Specialties International Seismic Application Technology 1020 CREWS ROAD, SUITE Q, MATTHEWS, NC 28105 704-841-4080 (PHONE) 704-841-4089 (FAX) www.isatsb.com PROPRIETARY STATEMENT THESE DRAWINGS/DOCUMENTS HEREIN ATTACHED ARE THE PROPERTY OF !.SAT. ANY REUSE OR REPRODUCTION OF THESE DOCUMENTS WITHOUT WRITTEN PERMISSION OF LSAT. IS STRICTLY FORBIDDEN. ALL RIGHTS RESERVED. DRAWN BY: SW - itier- INIERNATICaVAL APOUCA a ........ Project Name: Location: ISAT Project APPROVED BY: JOB NO: SEISMIC DESIGN FORCE (SOF) CALCULATION WORKSHEET NFPA /3 INTERNATIONAL SEISMIC APPLJCATION TECHNOLOGY 1020 Crews Road, Suite Q, Matthews, NC 28105 PHONE 704-841-4080 I FAX 704-841-4089 Date: 10/04/19 DATE: 10/7/2019 - - T10111 TeCHNOLOGY r.....A.e................. No. SESSIWIC Element by Westin Tukwila, WA NC21506 TABLE 1- PROJECT SEISMIC ENGINEERING PARAMETERS Note: The following Seismic Criteria was obtained from the structural portion of the project documents. Information not provided in the project documents has been derived from the code sections or tables noted below. Design spectral response acceleration (5% Damped) at short periods (ASCE 7-10, Section 1t4A) Ste = 0.97 Component Importance Factor (ASCE 7-10, Section 13.1.3) to = 1.50 Average Roof Height of Structure Relative to the Base Elevation h = 56.00 Factors vary depending on the utility service and materials of construction. See Table 3 below for values. Component Amplification Factor (ASCE 7-10, Table 13.6-1) 8,, = See Table 3 Component Response Modification Factor (ASCE 7-10, Table 13.6-1) R0 = See Table 3 Seismic Design Category (ASCE 7-10, Table 11.6-1) Seismic Design category = D TABLE 2- SEISMIC DESIGN' FORCE EQUATIONS (FROM ASCE 7-10 CHAPTER 13) F,, CALCULATION (Eq. 13.3-1) F‘,..„ - MAXIMUM OMIT (Eq. 13.3-2) F,„,,,„ -MINIMUM LAIIT (Eq. 13.3-3) F,, = 0.4a „x Se s x W„x (1 +2(c/1)) x0.7 Fp need not be greater than XI,, zW, x0.7 = 1.62 Fp shall not be less than 0.3xSpexl,yrW, x0.7 = 0.30 (R,/I,)1.6xS,, NOTE: Values in Table 2 are multiplied by 0.7 for conversion to "Allowable Stress Design' (ASCE 7-10, Section 2A.1) TABLE 3- SEISMIC DESIGN FORCE F,, Level Mechanical Pipe Carbon Steel, Copper Mechanical Pipe Low Deformabillty Plumbing Cast Ductile Iron HVAC Ductwork and Equipment Electrical Conduit Cable Tray Equip. Vibration Isolation Distributed Systems Equipment Level G is at or Below Grade ap = 2.5 R, = 4.5 ap = 2.5 R,, a 3.0 a,, .. 1.0 R,, = 2,5 at, = 2.5 R,, = 6.0 ap = 2.5 R,, - 6.0 8,, - 2.5 R,, = 2.5 G 0 0-30 0.34 030 030 0.30 0.41 1 15 0.35 0.52 0.30 0.30 0.30 0.82 2 25 0.43 0.84 0.31 0.32 0.32 0.77 3 35 0.51 0.76 0.36 0.38 0.38 0.91 4 45 0.59 0.88 0.42 0.44 0.44 1.06 NOTE: Values in Table 3 are the resultant after comparing Fp with Fp.max and Fp.min. Vertical Acceleration = 0.2 x 0.7x Sos F pv - 0.14 • Fire protecttonand natural gas always has an Importance Factor Ip = 1.6. z = Overhead Deck Elevation From Grade (ft.) Fp values on this SDF Worksheet are "Allowable Stress Design". Use this value In conjunction with ISAT Bracing Legends. A Division of Tomarco Contractor Specialties International Seismic Application Technology 1020 CREWS ROAD, SUITE Q, MATTHEWS, NC 28105 704-841-4080 (PHONE) 704-841-4089 (FAX) www.isatsb.com PROPRIETARY STATEMENT THESE DRAWINGS/DOCUMENTS HEREIN ATTACHED ARE THE PROPERTY OF !.SAT. ANY REUSE OR REPRODUCTION OF THESE DOCUMENTS WITHOUT WRITTEN PERMISSION OF LSAT. IS STRICTLY FORBIDDEN. ALL RIGHTS RESERVED. DRAWN BY: SW CHECKED BY: NB APPROVED BY: JOB NO: ENG PKG NO: DATE: 10/7/2019 OSHPD: ISCALE: N.T.S. REVISION: REV. BY ISSUE COMMENTS DATE A SW ISSUED FOR CONSTRUCTION 10/7/2019 A A A A SHEET TITLE: RESTRAINT LEGEND SEISMIC DETAILS & SDF DRAWING NO. : SB -1 "A Company Designed To Streamline Seismic Building Code Compliance" 5A CONSTRUCT! SPRWLERS NOT FEOUIFED OVERHANG Id I I �I��1�I�u���iull�i��l�l�llhl!I��I�!il�lhil�illlil��l! 11101111.1 Remote Area 4 Flowing Heads 11 Start Head PSI 127 Start Head GPM 130 SOFT per Head 130 Wet / Dry WET Hazard Ord. Grp. 1 Code NFPA 13 Construction (c1) Elev-Hd to Riser (') 240 PSI -Hd to Riser 8.66 Source Name or Location Source PSI Avail at Source 150 PSI Req'd at Source 123 Safety PSI 26.8 GPM Req'd at Source 482 Inside Hose 0.000 Duration of Source 0.000 (Outside Hose 250 Req'd Source Volume 0.000 i N 4 Max Density Available 0.166 GPM at Max Available Density 532 PSI loss - TOR to Source 4.74 Rack Demand 0.000 ■V 0 __Si 408) (407 4 11 114 112 ion 2-0 I 10-0 114. 0, Remote Area 4 Flowing Heads 11 Start Head PSI 127 Start Head GPM 130 SOFT per Head 130 Wet / Dry WET Hazard Ord. Grp. 1 Code NFPA 13 Construction Density 0.150 Area 1138 Len/WId Ratio 1.20 Max Velocity 20.6 Elev-Hd to Riser (') 240 PSI -Hd to Riser 8.66 Source Name or Location Source PSI Avail at Source 150 PSI Req'd at Source 123 Safety PSI 26.8 GPM Req'd at Source 482 Inside Hose 0.000 Duration of Source 0.000 (Outside Hose 250 Req'd Source Volume 0.000 Pressure Summary Available Pressure of 149.9 psi Exceeds Required Pressure of 123.1 psi This is a safety margin of 26.8 psi or 18 7. of Supply Advanced Summary Max Density Available 0.166 GPM at Max Available Density 532 PSI loss - TOR to Source 4.74 Rack Demand 0.000 6-512 pARDROO VI 109 t-.1:7) Density 0.150 Area 933 Len/Wiid Ratio 1.20 Max Velocity 26.3 11'-8' 114 11-4'& Cid `l) TELE CONF 4 IU•UIF:t0 DEM Hili' 1■■■I I■■■■L�1�►la UNISEX RR iI■ _`' ■•E©■■M■' •'• • ■A■ ■1 IMO ■I 1■ ►�I���� ■ ■■1; IIIMMENt I 10 ELF ■■■ j■ o ■■PURI 1 111•1111101111111111�■ ■■i_ I.ii■1 `�' ■ ■■■■I ��a ■ ■ 1D ■I ' ■ 01 ( an 4 4 tarp' EE ■-■i �1a ■I� o I■�■_i■1 ■■ ■■■11■ n,t o ■I 1 111111L1•�I■ ■E��I:ni>s�['�1>f�i ii En i 1� ■I IIIIII 1111111111111111 rmarn mE ilii.(■ '4 ®■I I■ ■■ A MEi - �■■■■�� 1■■■■■■MI MEM NMI 3' Remote Area 5 Flowing Heads 15 Start Head PSI 127 Start Head GPM 80.0 SOFT per Head 130 Wet / Dry WET Hazard Ord. Grp. I Code NFPA 13 Construction Density 0.150 Area 933 Len/Wiid Ratio 1.20 Max Velocity 26.3 Elev-Hd to Riser (') 240 PSI -Hd to Riser 8.66 Source Name or Location Source PSI Avail at Source 150 PSI Req'd at Source 133 Safety PSI 16.4 GPM Req'd at Source 547 Inside Hose 0.000 Duration of Source 0.000 (Outside Hose 250 Req'd Source Volume 0.000 Pressure I Available Pressure of 149.8 psi Exceeds Required Pressure of 133.5 psi Summary This is a safety margin of 16.4 psi at 11 X of Supply AdvancedMax Density Available 0.159 PSI loss - TOR to Source 5.8.3 Summary ( GPM at Max Available Density 580 (Rack Demand 0.000 MATCH LINE MATCH LINE - 1 IIire I Magri rAd re PA P FrAi 600A AlloWAOTOW 4 (625) (301) o0. 153 FR I Mit AIM/ 12-0 illal IN 19 ■ t ■ Ana f ■� (c ` I ■■■■■t2-° ■■[I 440 710 18' - 10 3/4" MATCH LINE MATCH LI WASHINGTON ATE CERTIFICATE OF COMPETENCY FIRE PROTECTION SPRINKLER SYSTEMS MATCH LINE MATCH LINE FIST ELOO� ■ L47s1 44 1.11. fitallillital Start Head PSI 127 Start Head GPM 96.0 SOFT per Head 130 Wet / Dry WET Hazard Ord. Grp. I Code NFPA 13 Construction Density 0.150 Area 953 Len/Wid Ratio 1.20 Max Velocity 18.0 mpg Source Name or Location Source PSI Avail at Source 150 PSI Req'd at Source 129 Safety PSI 21.0 , 1111 Available Pressure of 149.9 psi Exceeds Required Pressure of 128.9 psi This is a safety margin of 21.0 psi or 14 7b of Supply Advanced Summary 2-0 PSI loss - TOR to Source 3.76 Rack Demand 0.000 ■V __Si Ini•3)�--'(�■■ ion I.NI,mi 114. w.,i _MN !FREITAMIIPPE AUTOMATIC1 URRUiR 0 I ■■■■■■■■■ ■■■■U■■■,114 ■ t ■■■ck m■■L 5-° 4 ■■■■■■■■■ ■■■■�■■■■ ■■■i r• 1 4 ^ 114 13-812 f 0 0 0 0 r) 114 ^a� -I 11111 Cgt 111W.1101 111111111111111 114 114 5-012 - 8- mommantramtuommottelmomommatommommtemol CJ 111 12-0 -512 1 AUX. DRAIN NBTPECT'ORB TEST r-omanamottosouterammtmal CH LINE MATCH LINE 111,01111-1• LEGEND 1. FLOW SWITCH 2. 3" SUPERVISED BUTTERFLY VALVE 3. PRESSURE GAUGE 4. 3" CHECK VALVE 5. 1 1/4" AGF TEST/DRAIN 6. 1 1/4" CHECK VALVE 2 1/2" CONNECTION TYPICAL COMRINATION STANDPIPE Remote Area 3 Flowing Heads 10 Start Head PSI 127 Start Head GPM 96.0 SOFT per Head 130 Wet / Dry WET Hazard Ord. Grp. I Code NFPA 13 Construction Density 0.150 Area 953 Len/Wid Ratio 1.20 Max Velocity 18.0 Elev-Hd to Riser (') 240 PSI -Hd to Riser 8.66 Source Name or Location Source PSI Avail at Source 150 PSI Req'd at Source 129 Safety PSI 21.0 GPM Reid at Source 453 Inside Hose 0.000 Duration of Source 0.000 (Outside Hose 250 Req'd Source Volume 0.000 Pressure Summary Available Pressure of 149.9 psi Exceeds Required Pressure of 128.9 psi This is a safety margin of 21.0 psi or 14 7b of Supply Advanced Summary Max Density Available 0.162 GPM at Max Available Density 488 PSI loss - TOR to Source 3.76 Rack Demand 0.000 The Registered Professional Engineer stamp No. 50294 and signature that appear on this drawing apply only to approval of the 1SAT seismic bracing associated with the utilities shown on this drawing as delineated within the adjoining Seismic Bracing -Legend. S.I.N HEAD NOTES SYM. NO. PIPING DESCRIPTION REVISIONS D ATE VK462 VK458 VIKING VK462 5.6 1/2" 155' WHITE PENDENT CONCEALED VIKING VK458 7.4 3/4" 155' WHITE PENDENT 20X20 • 0 227 540 PENDENT ON CONCEALED PIPING PENDENT ON CONCEALED PIPING CONCEALED WHITE ESC. SEMI -RECESSED WHITE ESC. VK305 VK460 VK302 VK302 VIKING VK305 5.6 1/2" 155' WHITE SIDEWALL VIKING VK460 5.8 1/2" 155' WHITE SIDEWALL 16x16 16x20 1/6dwn VIKING VK302 5.6 1/2" 155' WHITE PENDENT 4 75 138 SIDEWALL ON CONCEALED PIPING SIDEWALL ON CONCEALED PIPING SEMI -RECESSED WHITE ESC. SEMI -RECESSED WHITE ESC. A TOTAL FIRE PROTECTION INC. 1004 7TH AVE. NORTH P.O. BOX 680 BRANDON SD. 57005 (605) 582-2400 e-mail: cbrandt@tfpsd.com DESIGN INSTALLER OWNER 86 PENDENT ON CONCEALED PIPING SEMI -RECESSED WHITE ESC. /g\ VIKING VK302 5.6 1/2" 155' WHITE PENDENT ENT COATING 0 22 PENDENT ON CONCEALED PIPING SEMI -RECESSED WHITE ESC. A A TOTAL RO'TECTION KI04 7TH AVE. NORTH P.O BOX 680 BRAIW:40N SD. 57005 ( 582-2400 T T L P�CTION INC. 1004 7TH AVE. NORTH P.O. BOX 680 EON & 57005 (605) 582-2400 INSTALL Building Permit #DW18-0295 Element By Westin 515 Industry Drive Tukwila, WA 99188 1 /8"=1'-0" Greg Lindholm Level Ill DRAWN BY: GREG LINDHOLM DATE 5-7-19 TOTAL A.S. 1088 SCALE: AS NOTED CHECKED BY: SHEET NO. 2oF6 FIRE PREVENTION DIVISION MATCH LINE MATCH LINE 1 -BED STUDIO K STUDIO K 10'-10" STUDIO K STA DARDII U STAN DAR ARD K 10' 10" 3' 9" FL I -P2 3-3 1 2 trl 114 114 12-0 3'-9" 10' 10" 10' 10" 3' 9" STUDIO Q STUDIO QQ STUDIO K STUDIO K 7' 7" STA " DAR $_ STUDIO QQ COMMONS SU E ELEV. LO X219 114 1141 ` 1 11-012 9-111 ! 7-10 7-212 6-2 7'-7" a1 tn 114 1ri1 ST a; DIO QQ 216 7-212 6-2 10-11 10-11 10-11 STUDIO 10-11 MATCH LINE WASHINGTON STATE CERTIFICATE OF COMPETENCY FIRE PROTECTION SPRINKLER SYSTEMS H LINE SECO\D FLOO� SGHE. 1/8=I-0" S.I.N VK462 HEAD NOTES SYM. NO. PIPING DESCRIPTION REVISIONS N itt LEGEND 1110111-1. FLOW SWITCH 3" SUPERVISED BUTTERFLY VALVE PRESSURE GAUGE 3" CHECK VALVE 1 1/4" AGF TEST/DRAIN 1 1/4" CHECK VALVE 1/2" CONNECTION TYPICAL y COMBINATION STANDPIPE LATCH LINE LATCH LINE AAI'A411411 -Aar. ....., Fr, ir. , ., . ,.............,.....,............................s.INAA- rairAmmiorAm Ar ArerAIMIA wireffor Apr .. is___ 1,9P - fir AirAmipp-ArtarailiwirAtrAikirrAimterimitr‘ Aso K III II BIRD K Mi) 11-212 11-012 1 -BED ADA TS AIA. DRAIN N{BTPECTORB TEST LINE ATCH LINE STAIR #1 ST -1 The Registered Professional Engineer stamp No. 50294 and signature that appear on this drawing apply only to approval of the ISAT seismic bracing associated with the utilities shown on this drawing as delineated within the adjoining Seismic Bracing Legend. DATE VK458 VIKING VK462 5.6 1/2" 155° WHITE PENDENT CONCEALED VIKING VK458 7.4 3/4" 155' WHITE PENDENT 20X20 VK305 VK460 VK302 VK302 VIKING VK305 5.6 1/2" 155' WHITE SIDEWALL • 227 540 75 PENDENT ON CONCEALED PIPING PENDENT ON CONCEALED PIPING SIDEWALL ON CONCEALED PIPING CONCEALED WHITE ESC. SEMI—RECESSED WHITE ESC. SEMI—RECESSED WHITE ESC. A VIKING VK460 5.8 1/2" 155' WHITE SIDEWALL 16x16 16x20 1/6dwn VIKING VK302 5.6 1/2" 155' WHITE PENDENT VIKING VK302 5.6 1/2" 155° WHITE PENDENT ENT COATING 138 SIDEWALL ON CONCEALED PIPING SEMI—RECESSED WHITE ESC. TOTAL FIRE PROTECTION INC. 1004 7TH AVE. NORTH P.O. BOX 680 BRANDON SD. 57005 (605) 582-2400 e—mail: cbrandt@tfpsd.com DESIGN INSTALLER OWNER 86 PENDENT ON CONCEALED PIPING SEMI—RECESSED WHITE ESC. A 0 22 PENDENT ON CONCEALED PIPING SEMI—RECESSED WHITE ESC. A A TOTAL ��tC TECTION 1004 7TH AVE. NORTH P.O. BOX 680 ERANDCW M 57005 (605) 582-2400 DEER: CECT UNDHOLM NIAL PROTECTION IN 1004 711-1 AVE NORTH P.O BOX 680 BRANDON SD. 57005 (605) 582-2400 NSTALLEFt Building Permit #DW18-0295 Element By Westin 515 Industry Drive Tukwila, WA 99188 .i N N N N Si fi M M W M ii. W Mi M 1 /8"=11-0" Greg Lwcl'dm Level III DRAWN BY: GREG LINDHOLM DATE 5-7-19 TOTAL A.S. 1088 SCALE: AS NOTED CHECKED BY: SHEET NO. 3 of 6 FIRE PREVENTION DIVISION MATCH LINE MATCH LINE 1O'-10"--;'--4' -6" 0 n 11111L 1 10-11 111111111•11111111111111111 WASHINGTON STATE CERTIFICATE OF COMPETENCY FIRE PROTECTION SPRINKLER SYSTEMS THIRD FLOO� xALE iib=r-o Cl 1 1. FLOW SWITCH 0 2. 3" SUPERVISED BUTTERFLY VALVE 3. PRESSURE GAUGE 4. 3" CHECK VALVE 5. 1 1/4" AGF TEST/DRAIN 6. 1 1/4" CHECK VALVE 2 1/2" CONNECTION TYPICAL COMBINATION STANDPIPE MATCH LINE MATCH LINE ory or oprer. Az"Jr. rimy . ,.,w ww.. -Alr,.*--td,m: 3 AI AMAIA0r1 4 ZrA":0 . .2, . 7,.........wrof A 1 i 1 1 -7 Freop rm - A „A _ illr e" A wow - r_ AA,. .44,7r Age -r.1-= Al ArAtedcarr AraimraparAwar.p_______N-Abeim_ qr-,-.2w A S 7' 7" ANDARD K 7' 7" STANDAR 9-114 11-012 11-041 AUX. DRAW WBTPECTORB TEST TCH LINE MATCH 'LINE The Registered Professional Engineer stamp No. 50294 and signature that appear on this drawing apply only to approval of the ISAT seismic bracing associated with the utilities shown on this drawing as delineated within the adjoining Seismic Bracing Legend. S.I.N HEAD NOTES VK462 VK458 VIKING VK462 5.6 1/2" 155° WHITE VIKING VK458 7.4 3/4" 155' WHITE PENDENT CONCEALED PENDENT 20X20 SYM. NO. 0 227 540 PIPING DESCRIPTION PENDENT ON CONCEALED PIPING PENDENT ON CONCEALED PIPING CONCEALED WHITE ESC. SEMI—RECESSED WHITE ESC. REVISIONS A DATE VK305 VK 460 VK302 VK302 VIKING VK305 5.6 1/2" 155' WHITE SIDEWALL VIKING VK460 5.8 1/2" 155' WHITE SIDEWALL 16x16 16x20 1/6dwn VIKING VK302 5.6 1/2" 155° WHITE PENDENT VIKING VK302 5.6 1/2" 155' WHITE PENDENT ENT COATING a 41 75 138 SIDEWALL ON CONCEALED PIPING SIDEWALL ON CONCEALED PIPING SEMI—RECESSED WHITE ESC. SEMI—RECESSED WHITE ESC. A TOTAL FIRE PROTECTION INC. 1004 7TH AVE. NORTH P.O. BOX 680 BRANDON SD. 57005 (605) 582-2400 e—mail: cbrandt@tfpsd.com DESIGN! INSTALLER OWNER 86 PENDENT ON CONCEALED PIPING SEMI—RECESSED WHITE ESC. A 22 PENDENT ON CONCEALED PIPING SEMI—RECESSED WHITE ESC. A A NROTECTION 5004 7TH AVE NORTH P.O. BOX 680 SON SD. 57005 (605) 582-2400 DE • GREG UNDHOLM T -A-AL FI CTION IN 1004 7TH AVE NORTH P.O. BOX 680 BRANDas1 M. 57005 (605) 582-2400 Building Permit #DW18-0295 Element By Westin 515 Industry Drive Tukwila, WA 99188 H K M M K M N !. ►{ IF. Y° IM W M Greg Lindholm 11144600 Level Ill DRAWN BY: GREG LINDHOLM DATE 5-7-19 TOTAL A.S. 1088 SCALE: AS NOTED CHECKED BY: SHEET NO. 4OF6 FIRE PREVENTION DIVISION MATCH LINE MATCH LINE STUDIO QQ N STUDIO K Iii I�1 STUDIO K STUDIO K 442 7-10'2 7' 5" 7' 9" re 4 NGINEER'S OFFICE 7-22LINEN-92 3-101s STUDIO QQ = STUDIO QQ STUDIO K STUDIO K = STUDIO K STANDARD K = STUDIO QQ STUDIO QQ 11-012 6-2 10-11 O® STUDIO ■III;OUII-1' 10-1012 ST DIOQQ 416 TUDIOQ LEGEND 1. FLOW SWITCH ANDARD 2. 3" SUPERVISED BUTTERFLY VALVE 3. PRESSURE GAUGE 4. 3" CHECK VALVE 5. 1 1/4" AGF TEST/DRAIN 6. 1 1/4" CHECK VALVE 2 1/2" CONNECTION TYPICAL y COMBING MATCH LINE MATCH LINE rimy 4 _Ai A. Ail i�/ �� Ai.i .....44ISI / i�4011 /..1ir .• A, iii,riA ,Aira Air 51E `% 2.11i8'1I% �A .tH LINE -10'2 S 407 10-11 0 Mt ST STUDIO • UDIO K 410 MII =a STUDIO 409 K MATCH LINE • (205) TCH LINE (613 114 11 -�I (A2) 1-BEi 401 WASHINGTON STATE CERTIFICATE OF CONPEsTENCY FIRE PROTECTION SPRINKLER 3Y3TE FOUTH TLOO� Remote Area 2 Flowing Heads 7 Start Head PSI 113 Start Head GPM 324 SOFT per Head 324 Wet / Dry WET Hazard Light Code NFPA 13 Construction Density 0.150 Area RM Design Len/Md Ratio 1.20 Max Velocity 20.3 Elev—Hd to Riser (') 604 PSI —Hd to Riser 21.8 Source Name or Location Source PSI Avail at Source 150 PSI Req'd at Source 130 Safety PSI 19.7 GPM Req'd at Source 438 (Inside Hose 0.000 Duration of Source 0.000 Outside Hose 100 Req'd Source Volume 0.000 Pressure Summary Available Pressure of 149.9 psi Exceeds Required Pressure of 130.2 psi This is a safety margin of 19.7 psi or 13 % of Supply Advanced Summary Max Density Available 0.161 GPM at Max Available Density 470 PSI loss — TOR to Source 6.25 Rack Demand 0.000 FL n: . FK 114 11-2'2 — 51 AREA G7 AUX. DRAIN NSTPECTORS TEST MATCH LINE The Registered Professional Engineer stamp No. 50294 and signature that appear on this drawing apply only to approval of the ISAT seismic bracing associated with the utilities shown on this drawing as delineated within the adjoining Seismic Bracing Legend. S.I.N VK462 HEAD NOTES VIKING VK462 5.6 1/2" 155 SYM. NO. PIPING • WHITE PENDENT CONCEALED 227 PENDENT ON DESCRIPTION CONCEALED PIPING VK458 VIKING VK458 7.4 3/4" 155 ' WHITE PENDENT 20X20 540 PENDENT ON CONCEALED PIPING VK 305 VK 460 VK302 VIKING VK305 5.6 1/2" 155' WHITE VIKING VK460 5.8 1/2" 155' WHITE VIKING VK302 5.6 1_/2" 155' WHITE SIDEWALL SIDEWALL PENDENT 75 SIDEWALL ON CONCEALED PIPING 16x16 16x20 1/6dwn 138 86 SIDEWALL ON CONCEALED PIPING PENDENT ON CONCEALED PIPING VK302 VIKING VK302 5.6 1/2" 155° WHITE PENDENT ENT COATING • 22 PENDENT ON CONCEALED PIPING CONCEALED WHITE ESC. SEMI—RECESSED WHITE ESC. SEMI—RECESSED WHITE ESC. SEMI—RECESSED WHITE ESC. SEMI—RECESSED WHITE ESC. SEMI—RECESSED WHITE ESC. REVISIONS e DATE TOTAL FIRE PROTECTION INC. 1004 7TH AVE. NORTH P.O. BOX 680 BRANDON SD. 57005 (605) 582-2400 e—mail: cbrandt@tfpsd.com 4 DESIGN INSTALLER OWNER A 6 OL �ECTION 1004 7TH AVE. NORTH P.O. MX 680 BRANDON SD. 57005 (605) 582-2400 DESI 4ER: WEG UNDHOL M TAL ColECTION 1004 7TH AVE. NORTH P.O. BOX 680 ERANDON W. 57005 (605) 582-2400 UsISTALIEft Building Permit #DW18-0295 Element By Westin 515' Industry Drive Tukwila, WA 99188 M.° 4. M1141 M }. M M ... F. aro tYil M M 1 /8"=l'-0" (keg Litcholm 1144600 Level III DRAWN BY: GREG LINDHOLM DATE 5-7-19 TOTAL A.S. 1088 SCALE: AS NOTED CHECKED BY: SHEET NO. 5 OF 6 FIRE PREVENTION DIVISION FIRE ALARM AND SMOKE CONTROL SHOP DRAWINGS FOR A NEW FACILITY: PROJECT LOCATION BY WEST N SITE ADDRESS: 515 INDUSTRY DRIVE TUKWILA, WA 98188 5;52ni St .__....._ S 152nd SI kl.+,f. C ane hAtryTal_ 'SW 16th St: - Nonpbn.:n- :... SextlloSnt:^.cL^.±_ J'etden Stay .. nnerica:. �� I Sa-1li1 pg hunala W.t .... '1.0033c E>WaY City n,:rrseiiiivy: { ‘ierho SfY�Rr SOUthrtes Ma?I oe ne ^t .. of Fnrk Strander BI,d 51Slndnstry Dr, ruts it. WA4818� SWV 2C a rF,t; roa.rr: CTrcn n+kra:un. SW 35th St..... _... Ham r!-ae Se,±r Trilar [St -- Cnoccler n Oer_z, The Homy i4Cot.. S 180th St -.tv : ti m Cr'.ei'"vt Cate :MrtCbmo'...... -MCI weenrejorieSS - V ' BUILDING INFORMATION FLOORS: 5 SQ. FT.: 116,665 OCCUPANCY: R1 UNITS: 177 BUILDING TYPE: V-A SPRINKLERED: YES FA -5 FLOOR 1 INITIATING ANDKE_ ......SMO CONTROL PLAN.... FA -6 FLOOR 2 INITIATING AND SMOKE CONTROL PLAN AC 'et ❑ Without Comments ❑ As Noted in Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptance is subject to errors and omissions which do noc authorize violations of adopted eafaer standards and ordinances. The responsibility for the adequacy of design rests totally with die designer. Additions, deletions on revisions to these drawings after this date will void this acceptance and will require a • resubmittal of revised drawings for subsequent approval, Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: 7-1°1 cl. By: s'7 J Fire Permit Number Iq-F-1.s To schedule inspections call 206-575-4407 110TICE A complete:-\, signed Tukwila Fire Department Pre-test Certificate must'ae presented to the Inspector prior to commencement of Acceptance. Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing DRAWINGS PREPARED BY: 'Re/lance /zt1c 4795 OAKLAND STREET DENVER, CO 80239 (720) 749-2850 WWW. RELIANCETEAM.COM FIRE ALARM SCOPE OF WORK FIRE ALARM AND SMOKE CONTROL SYSTEMS FOR A 5 FLOOR, 116,665 SQUARE FOOT ELEMENT HOTEL BY WESTIN. THE SYSTEM SHALL INCLUDE CLUDE AUTOMATI DETECTION PER MARRIOTT LIFE SAFETY STANDARDS AND THE INTERNATIONAL FIRE CODE, SPRINKLER MONITORING, VOICE EVACUATION, FIRE-FIGHTER TELEPHONES AND THE CONTROL AND MONITORING FOR THE PRESSURIZED STAIRWELLS AND SMOKE EXHAUST SYSTEMS AND SHALL COMPLY WITH ALL APPLICABLE CODES AND STANDARDS INCLUDING CITY OF TUKWILA CITY ORDINANCES AND THE CODE AMENDMENTS FROM CITY OF TUKWILA AND WASHINGTON STATE. PROJECT CONTACTS PAGE NO. BUILDING OWNER GENERAL CONTRACTOR ELECTRICAL ENGINEER SMOKE CONTROL ENGINEER AUTHORITY HAVING JURISDICTION TUKWILA HOTEL GROUP, LLC 1735 S 19TH AVENUE, SUITE B BOZEMAN, MT 59718 KEY CONSTRUCTION 263 19515 KNKASSELMAN@KEYCONSTRUCTION.COM r ROBINSON ENGINEERING, INC.(316) (206) 364-3343 UNITED BUILDING & ENGINEERING SVCS (425) 591-4633 BOB LONG UNITEDBES.COM CITY OF TUKWILA FIRE MARSHAL'S OFFICE (206) 575-4407 FIREMARSHAL@TUKWILAWA.GOV Drawing/Document prepared by: Ephriam J. Bistline NICET Certification No. 136272 Fire Alarm Systems - Level IV Certification Expires: 05/01/2019 SHEET INDEX PAGE NO. PAGE NAME iCOVER COVER SHEET FA -1 FIRE ALARM GENERAL INFORMATION FA -2 FIRE ALARM SLC & BAKCBONE RISER FA -3 FIRE ALARM NAC RISER FA -4 SMOKE CONTROL RISER AND DETAILS FA -5 FLOOR 1 INITIATING ANDKE_ ......SMO CONTROL PLAN.... FA -6 FLOOR 2 INITIATING AND SMOKE CONTROL PLAN FA -7 FLOOR 3 INITIATING AND SMOKE CONTROL PLAN FA -8 FLOOR 4 INITIATING AND SMOKE CONTROL PLAN FA -9 FLOOR 5 INITIATING AND SMOKE CONTROL PLAN FA -10 ROOF INITIATING AND SMOKE CONTROL PLAN FA -11 FLOOR 1 NOTIFICATION PLAN FA -12 FLOOR 2 NOTIFICATION PLAN FA -13 FLOOR 3 NOTIFICATION PLAN FA -14 FLOOR 4 NOTIFICATION PLAN FA -15 FLOOR 5 NOTIFICATION PLAN FA -16 FIRE SMOKE CONTROL PANEL RELIANCE ELECTRIC CONTACTS DRAWINGS PREPARED BY DRAWINGS CHECKED BY RELIANCE PROJECT MANAGER EJ BISTLINE (702) 343-3674 EJ.BISTLINE@RELIANCETEAM.COM RULON MUSSER - (720) 250-7675 RULON.MUSSER@RELIANCETEAM.COM RULON MUSSER - (720) 250-7675 RULON.MUSSER@RELIANCETEAM.COM ?pro ip 1 ri)19 TUFIRE SYMBOL LEGEND QTY SYMBOL DESCRIPTION MANUFACTURER PART NUMBER MOUNTING CONTROL / POWER PANELS 2 18/2 FIRE ALARM CONTROL PANEL KIDDE VS4-GD BACKBOX I ACP SLC CIRCUITS 19 MC CABLE FIRE ALARM REMOTE POWER PANEL KIDDE MIRBPS10A BACKBOX FAPPx SLC4 SLC4 5 e FIRE ALARM REMOTE AMPLIFIER KIDDE APS10A / SIGA-AA50 BACKBOX AMPx NACI NACI 2 (FAA) FIRE ALARM REMOTE ANNUNCIATOR PANEL KIDDE K-RLCD-C 4S BOX FPLR* INITIATING DEVICES 135 O SMOKE DETECTOR WITH STANDARD BASE KIDDE KI -PD / KI -SB 3" ROUND BOX 233 SB SMOKE DETECTOR WITH LOW FREQUENCY SOUNDER BASE KIDDE KI -PD / KI-ABLT 4S BOX. 13 OH HEAT DETECTOR WITH STANDARD BASE KIDDE KI-HRD / KI -SB 3" ROUND BOX 4 % DUCT SMOKE DETECTOR KIDDE GSA -SD N/A 2 N/A MANUAL PULL STATION KIDDE GSA -M278 1 GANG BOX F • 3 CO CARBON MONOXIDE DETECTOR SYSTEM SENSOR CO -1224T / CO-1224TR I GANG BOX MONITORING / CONTROL MODULES 4 e FIRE ALARM CONTROL RELAY KIDDE GSA -CR 1 GANG BOX 35 41:H FIRE ALARM HIGH VOLTAGE CONTROL RELAY KIDDE GSA -CRH 4S BOX 12 SINGLE INPUT MODULE KIDDE GSA -CTI 1 GANG BOX 42 62 DUAL INPUT MODULE KIDDE GSA-CT2 1 GANG BOX 16 413,REMOTE MONITOR MODULE KIDDE GSA -RMI 2 GANG BOX 194 ® SIGNAL CONTROL MODULE KIDDE GSA -CCI 2 GANG BOX NOTIFICATION DEVICES 306 15 1W WALL MOUNT SPEAKER STROBE (CANDELA AND WATTAGE INDICATED) KIDDE G4HFWF-S7VMC 4S BOX 0 o 17 15 1W p c CEILING MOUNT SPEAKER STROBE (CANDELA AND WATTAGE INDICATED) KIDDE GCHFWF-S7VMC 4S BOX 2 WP • WEATHER PROOF SPEAKER STROBE (CANDELA AND WATTAGE INDICATED) KIDDE INT-4ASW BACKBOX OIs 19 '�`15 WALL MOUNT STROBE (CANDELA INDICATED) KIDDE EG1 F -VM 1 GANG BOX 1 10ON WEATHERPROOF HORN STROBE AND BACKBOX (CANDELA INDICATED) KIDDE INT-8ATW / INT-WBW BACKBOX • • DEVICES FOR AUXILIARY FUNCTIONS 15I FIREFIGHTER PHONE JACK KIDDE 6833-4 1 GANG BOX I J 29 MAGNETIC DOOR HOLDER INTERLOGIX DHF -24120C 1 GANG BOX DH o 16 o FIRE / SMOKE DAMPER (SUPPLIED AND INSTALLED BY OTHERS) N/A N/A N/A (Fso) WIRE LEGEND LINETYPE DESCRIPTION WIRE SIZE /-NO OF CONDUCTORS JACKET JACKET COLOR CONDUIT Original Drawing SMOKE CONTROL CIRCUITS 18/2 2 HR CI RATED RED EMT sc sc 0 SLC CIRCUITS 18/2 MC CABLE RED NONE SLCI SLCI SLC3 SLC3 SLC4 SLC4 SLCS RCS e NOTIFICATION CIRCUITS 14/2 FPLR RED NONE NACI NACI NAC NAC NU NAC3 NAC4 NAC4 • SPEAKER CIRCUITS 16/2 SHIELDED FPLR* ORANGE NONE* SPKR Sari • DATA BUS CIRCUITS 18/4 2 HR CI RATED RED EMT DBMS DBMS NICET Certification No. 136272 SENS Circuits 18/4 2 HR CI RATED RED EMT SL,,S segs AR 24V AUXILIARY POWER CIRCUITS 18/2 ZIP WHITE NONE AUX Aux PM-- 120V CIRCUITS** N/A N/A N/A N/A 120V 120V *Speaker circuits between control panels and amplifiers shall be CI Rated and enclosed in metal raceways. **120V Circuits shown for reference only. These will be supplied, installed and terminated by the electrical contractor. INPUT / OUTPUT MATRIX Control Unit Annunciation Notification Control Smoke Control Open Circuit 0 0 Date Revision Notes • • Original Drawing 0 2019/04/23 • 2 • Device relocations per Owner 0 0 o 4 5 • o e 0 • 1 2 Circuit Short • o • • • • 12 • 1 • • • Drawing/Document prepared by: Ephriam J. Bistline NICET Certification No. 136272 Fire Alarm Systems - Level IV Certification Expires: 05/01/2019 _____Z4Zsi________ • • o o • 2 System Ground Fault • • • e o o • o o • • 0 0 o • 3 AC Power Fail o • • • o • 0 0 • 0 • • • • • 0 4 Fire Alarm System Low Battery • o 0 o • o • o • • o • • • o 0 5 Device Fail o o • • o o• • o • • o o o o • 6 Device Missing 0 o • • o • o • 0 • o • • o • o 7 Device Out of Tolerance • • • • o o • 0 • • o o • o o 0 8 Common Area Smoke Detector 0 0 Date Revision Notes 0 2018/12/26 Original Drawing 0 2019/04/23 • 2 2019/05/08 Device relocations per Owner 0 0 o 4 5 • o e 0 • 10 E cis < Heat Detector • o 10 • • 12 1 • • • Drawing/Document prepared by: Ephriam J. Bistline NICET Certification No. 136272 Fire Alarm Systems - Level IV Certification Expires: 05/01/2019 _____Z4Zsi________ • • o o • 11 Manual Pull Station • • o o o o • • 0 0 o • 12 1st Floor Elevator Lobby Smoke Detector o • o • 0 • 0 • • • • • 0 13 2nd - 5th Floors Elevator Lobby Smoke Detector • o • o f,: o • • o • • • o 0 14 Elevator Hoistway Smoke Detector o o o o• o • • o o o o • 15 Elevator Hoistway Heat Detector 0 o o • • 0 • o • • o • o 16 Elevator Equipment Room Smoke Detector • • o o 0 • • o o • o o 0 17 Elevator Equipment Room Heat Detector • • 0 0 o • • o • • o • • 18 Fire Sprinkler Waterflow 0 o e 0 o o 0 • 0 0 • • 19 20 Fire Sprinkler Valve Tamper • 0 0 21 Guest Suite Smoke Detector 0 0 0 0 22 Duct Smoke Detector • 0 • • 23 Carbon Monoxide Detector • 0 • 24 FAPP ROUGH -IN DETAIL 9 0 C 5'-6" AFF / / FINISHED FLOOR MOUNTING HEIGHTS CEILING LINE RAU 42" Min 48" Max V 80" Min 6" 6" Min 96" Max 90" Min V / / / mm© / A 60" 66" / / / FINISHED FLOOR FAPP / AMP ROUGH -IN DETAIL Power stub on left side of stud 5'-0" AFF Fire Alarm wire stub on right side of stud *Protect stubbed wires and cables from physical damage using conduit or nail and tape. / / FINISHED FLOOR FIRE ALARM GENERAL NOTES 1. Fire alarm contractor will coordinate with fire sprinkler contractor to ensure that all waterflow devices and all required valves are monitored. This includes the PIV if applicable. 2. Smoke / heat detectors located next to fire alarm control units, remote power supplies and amplifier panels shall be located directly above the panel as much as possible. 3. Ensure all smoke detectors are located not less than 36" from HVAC air vents and diffusers. 4. No smoke detectors shall be installed until after construction clean-up of all trades is complete. 5. The electrical circuit breaker for all fire alarm control panels, power supplies and amplifier panels shall be red in color, clearly marked "Fire Alarm" and a breaker lock shall be installed. 6. Magnetic Door Holder power shall be discontinued in the event of A/C power loss to prevent excessive battery usage. 7. Monitor modules / control relays for outside HVAC units shall either be installed inside the building in an accessible location or in weatherproof enclosures. 8. Fire Alarm contractor shall provide a printer for the fire alarm system. APPLICABLE CODES AND STANDARDS 1. 2015 International Building Code (IBC) with Tukwila City Amendments 2. 2015 International Fire Code (IFC) with Tukwila City Amendments 3. 2016 NFPA 72 Fire Alarm and Signaling Code 4. 2017 National Electric Code (NEC) 5. Tukwila City Ordinance No. 2437 6. Tukwila City Ordinance No. 2330 7. Marriott Module 14 Life Safety Standards TERMINAL WIRING METHODS INCORRECT CORRECT DETECTOR MOUNTING DETAIL CEILING Acceptable here Top of detector acceptable within 12" of ceiling Never below here Note: Measurements shown are to the closest edge of the detector co O N SIDEWALL Example of Proper Detector Mounting NFPA 72 2016 A.17.6.3.1.3.1 a) a) ��-EAA+ VJ (o CD 0 LC)C) 1.0 I C) M N cD CO 0 -oCo 0 0 U 1- a) a) 0 ianceteam.com awn By: EJB Checked By: JPJ Job #: 1903 Revisions: # Date Revision Notes 0 2018/12/26 Original Drawing 1 2019/04/23 Changes for Smoke Control / HVAC Coordination 2 2019/05/08 Device relocations per Owner 3 4 5 6 7 8 9 10 11 12 Engineers Stamp: Drawing/Document prepared by: Ephriam J. Bistline NICET Certification No. 136272 Fire Alarm Systems - Level IV Certification Expires: 05/01/2019 _____Z4Zsi________ This Drawing is the exclusive Property Of Reliance Electric, and was prepared for the exclusive use of Reliance Electric and its affiliates, for the services performed by Reliance Electric. No use, reproduction or duplication of this drawing or associated documents, in part or whole may be made without the written consent of Reliance Electric. This Drawing does not constitute an enaineers or architP_cts annrnval but is nnnsiriarari a shnn rirawinn for installation purposes of Reliance Electric. Sheet Number: FA -1 Fire Alarm General Information � Backbone Riser Diagram Dedicated 120V from building electrical system. Panel and circuit to be field assigned. Power Supply MIRBPS6A SLA Batteries FAPP16 120V Dedicated 120V from building electrical system. Panel and circuit to be field assigned. Power Supply MIRBPS6A SLA Batteries FAPP17 Power Supply MIRBPS6A SLA Batteries FAPP18 120/ Dedicated 120V from building electrical system. Panel and circuit to be field assigned. Power Supply MIRBPS6A SLA Batteries FAPP19 Floor 5 Dedicated 120V from building electrical system. Panel and circuit to be field assigned. CC Dedicated 120V from building electrical system. Panel and circuit to be field �— assigned. FACP2 SLA Batteries Power Supply MIRBPS6A SLA Batteries FAPP15 1202 Dedicated 120V from building electrical system. Panel and circuit to be field assigned. Power Supply MIRBPS6A SLA Batteries FAPP14 Power Supply MIRBPS6A 120V Dedicated 120V from building electrical system. Panel and circuit to be field assigned. SLA Batteries FAPP13 Power Supply MIRBPS6A SLA Batteries FAPP12 Floor 4 Dedicated 120V from building electrical system. Panel and circuit to be field assigned. AMP6 AMPS 1202 Power Supply SLA Batteries ten Cel Power Supply MIRBPS6A SLA Batteries FAPP8 120V Dedicated 120V from building electrical system. Panel and circuit to be field assigned. Power Supply MIRBPS6A SLA Batteries FAPP9 Power Supply MIRBPS6A 120/ Dedicated 120V from building electrical system. Panel and circuit to be field assigned. SLA Batteries FAPP10 Power Supply MIRBPS6A SLA Batteries FAPP11 LIS Floor 3 Dedicated 120V from building electrical system. Panel and circuit to be field assigned. AMP4 AMPS Power —1202 --l_ Supply SLA Batteries CO 3/3 CO Power Supply MIRBPS6A SLA Batteries FAPP7 120V Dedicated 120V from building electrical system. Panel and circuit to be field assigned. Power Supply MIRBPS6A SLA Batteries FAPP6 Power Supply MIRBPS6A SLA =atteries FAPP5 1201 Dedicated 120V from building electrical system. Panel and circuit to be field assigned. Power Supply MIRBPS6A SLAB tteries FAPP4 Floor 2 Dedicated 120V from building electrical system. Panel and circuit to be field assigned. 120V Dedicated 120V from building electrical system. Panel and circuit to be field assigned. Dedicated 120V from building electrical system. Panel and circuit to be field assigned. Connection to AES radio for off-site monitoring. Power Supply MIRBPS6A SLA Batteries FAPP1 Dedicated 120V from building electrical system. Panel and circuit to be field assigned. Power Supply MIRBPS6A SLA Batteries FAPP2 120/ Power Supply MIRBPS6A SLA atteries FAPP3 Floor 1 Riser Notes 1. All smoke control circuit cabling shall be 2 -hour fire rated cable enclosed in metallic raceway. Raceway provided and installed by Electrical Contractor. 2. All SLC circuit cabling shall be MC cable listed for use as fire alarm cabling. 3. All fire alarm control/monitor modules for units/dampers on roof shall be suitably protected from the weather. This shall be accomplished by either providing a weatherproof enclosure or installing the devices inside the building. SLC and Smoke Control Riser Diagram O ©SBO ©SBO 0 ® O 0 OSB O O ©SB 0 © O ©SBO 0 OSB ® OSB © ©SB O ©SB ©SB O OSB © OSB X2 X2 X2 x2 X2 ©SB © ©SB ® ©SB ®SB O ©SB O ©SB 0 ©SB ® ©SB O ©SB ® ©SB O © ©SB O ©SB 0 ©SB O ®2 © ©SB O X2 X3 X2 X2 X2 X2 O OSB ©SB O ©SB ©B ® © OSB OOSB O © ® ©SB O ID O © O X2 X2SB X2 FAPP X4 AMP O OSBO OSBO 0 SBO OSB® 0 SLCS 0E5 SLCS 0,3 LIZ ® ©SBO OSB ® OSB ® OSB O OSB ®O ® OSB ® © OSB ®O ® OSB ®O ©SB ® O OSB ® OSB © OSB ® ©SB OSB ® OSB OSB ® OSB ® ©SB ® OSB t3� O X2 X2 X2 X2 X2 X2 X2 X3 X2 X2 X2 X2 X2 XZ X2 OSB ® OSB ® OSB ® OSB t3� OSB ® OSB ® ©SB ® ©SB ® ©B 420 O ® OSB ® ©SB © C2 ©SB it O ® OSB O ©SB ® OSB O OSB ® OSB O ® OSB O OSB ® © X3 X2 X2 X2 X2 X2 0E4 FAPP X4 SLC4 5124 FACP2 SLA Batteries OSB ® OSB ® OSB O OSB ® ©SB ® OSB O ©SB ®©® ©SB ®© ©SB ® O ® ©SB ®O OSB X3 X2 X2 X2 X2 00000000004,000000060 0 OSB 0 ©SB 0 ©SB 0 ©SB ® © ©SB ® ©SB 0 ©SB © ®2 © ©SB ® OSB© OSB 0 OSB X2 X2 X2 X2 O 0 OSB ® 02sX2B ® OSB® 0BO OSB0 ©B0 ©SB® OSB® OSBtat X3 2 X2 X2 X2 O ® OsB ® OSB ® o OSB ® OSB 43 X2 X2 X2 X4 SLC3 5123 SLC3 OSB ® OSB ® OSB ® OSB OSB ©SB © ©SB ID OSB O ® OSB t3� O O ©SB © ® ©SBO ® OSB to OSB O ©SB OSB OSB O OSB ® OSB ® OSB ® OSB ® OSB X2 X2 X3 X2 X2 X2 X4 X3 X2 X2 OSB ® OSB ® OSB ©SB ® ©B ® SSB ® ©SB OSB O ® ©SB 4:2 O ©SB 40 OSB O ©SB ® O ©B ® © ©SB ® ©SB © ©SB ® OSB CD 0 X2 X2 AMP FAPP X4 ©0 Oo 0 ©.SB X2 S X2 SLC2 SLC2 Cil 000 0SBID®0OSBO©SB®©SBIDOSB®OSBOOSB00SB00SB®OSBO©O©OIDO © O X2 X2 X5 OSB O OSB O O OSB ®O ® OSB O ©SB t3� OSB O FAPP X2 O CP Vii1V O 3 AMP FAPP X24 X4 X2 X3 C►©eOO©O©O X4 X2 X5 SLCI SLCI 1,3 0.3 Fyr I" � FACP1 SLA Batteries Smoke Control Circuit Roof Floor 5 Floor 4 Floor 3 Floor 2 Floor 1 0) C V 0 VJ I, CD CO LC)0 0) LS) O TT1 0) CO 0 CO 0 0 U a) n� W 0 E t0 V E co a) a) U co awn Bv: EJB Checked By: JPJ Job #: 1903 Revisions: ElevatorroperRelief Date FSD FSD FSD �� ) Damper t FSD ( FSD) ( FSD) ( FSD) FSD Original Drawing 1 I I I I 2 2019/05/08 Device relocations per Owner 3 4 5 6 7 8 9 10 02 CoH 11 02 0H SC 0 02 0H 0H 02 0 02 0H Fire Alarm Systems - Level IV Certification Expires: 05/01/2019 AOM H�H 02 This Drawing is the exclusive Property Of Reliance Electric, and was prepared for the exclusive use of Reliance Electric and its affiliates, for the services performed by Reliance Electric. No use, reproduction or duplication of this drawing or associated documents, in part or whole may be made without the written consent of Reliance Electric. This Drawing does not constitute an Pnninaarc nr arrthitartc annrnual hitt is rnnciriarari a chnn rirauiinn 02 �.J 02 O 0 4H 5/ 0H _ 0 0 --( FSD) 2 H 02 OHFSD 0 0 —( FSD) 0H 02� FSD) 0 0 -( FSD) 2 H L9 02 OH—( FSD) 02 0H--( FSD) 02 OH FSD 0 OH—( FSD) -( FSD) 2 H y C1 C7 0 0 —( FSD) 2 H 02 C)H— ( FSD) 6' 02 •'®H--( FSD) 02 OH FSD 0 • ®H FSD 2 y 5 2 0 0H<) h 02 OHFSD 0 OH-( FSD) OH 02 FSD 0 • ®H FSD 6 02 OH --( FSD) 02 O--( FSD) O 0 Makeup Ai Damper r H 2 0 0 --1 Motorized Door CI -(FSD) SC SC SC SC SC SC SC SC SC SC SC Roof Floor 5 Floor 4 Floor 3 Floor 2 Floor 1 0) C V 0 VJ I, CD CO LC)0 0) LS) O TT1 0) CO 0 CO 0 0 U a) n� W 0 E t0 V E co a) a) U co awn Bv: EJB Checked By: JPJ Job #: 1903 Revisions: # Date Revision Notes 0 2018/12/26 Original Drawing 1 2019/04/23 Changes for Smoke Control / HVAC Coordination 2 2019/05/08 Device relocations per Owner 3 4 5 6 7 8 9 10 11 12 Engineers Stamp: Drawing/Document prepared by: Ephriam J. Bistline NICET Certification No. 136272 Fire Alarm Systems - Level IV Certification Expires: 05/01/2019 4.--,./7.----4----, This Drawing is the exclusive Property Of Reliance Electric, and was prepared for the exclusive use of Reliance Electric and its affiliates, for the services performed by Reliance Electric. No use, reproduction or duplication of this drawing or associated documents, in part or whole may be made without the written consent of Reliance Electric. This Drawing does not constitute an Pnninaarc nr arrthitartc annrnual hitt is rnnciriarari a chnn rirauiinn for installation purposes of Reliance Electric. Sheet Number: FA -2 Fire Alarm SLC & Smoke Control Risers Floors 1-3 Notification Riser Diagram Floor 3 NAC3 NAC3 NAC3 X15 1W 1W • NACI NACI NAC3 NACI NACI 1W 15 1W 30 X2 X2 X2 ,15 1W ,Q. Power Supply MIRBPS6A SLA Batteries FAPP11 Power Supply X3 NAC X2 NAC X2 Power Supply X2 NACI NACI 1W 110 1W NACI 1W 110 Q SLA Batteries FAPP8 Floor 2 NAC Power Supply NAC3 NAC3 NAC3 1W 110 _ 1W 110 1W . 110 1W NACI NACI 1W 110 1W NACI 15 Power Supply NAC3 ©sB X11 Power Supply X3 NAC 1W 110 0 X2 X2 ® Ss X11 NAC3 1W 110 X2 NACI 1W10 411, FAPP5 Power Supply MIRBPS6A SLA Batteries FAPP4 Floor 1 NAC 1WA10 Power Supply NAC NACI X2 Power Supply 2W 15 1W 15 2W 75 1W 30 2W 75 1W 15 1W 30 iCI CI 0 0 �Oi O X2 X2 X2 Power Supply MIRBPS6A SLA Batteries FAPP1 Floors 4-5 Notification Riser Diagram Floor 5 ©SB X11 NAC3 NAG NACI X2 C2 Power Supply MIRBPS6A SLA `Batteries FAPP19 Power Supply SLA Batteries FAPP18 Power Supply 1W 110 1w 0 NAC NAC3 NAC3 NAC3 NAC2 NAC2 le ©SB X16 ` /15 1W 110 X3 X2 Power Supply MIRBPS6A SLA Batteries FAPP16 Floor 4 NAEI X2 ® ©SB X16 NACI NAEI 1W 110 1W NACI NAC3 X2 NAC X2 NACI 1W 110 Power Supply MIRBPS6A SLA Batteries FAPP14 X3 Power Supply NACI • NAC X2 1W 110 NAC3 X3 NAC3 1W C17. 110 iso X2 X2 ®SB X16 X2 Power Supply MIRBPS6A SLA Batteries FAPP12 Speaker Riser Diagram Floor 5 1W 1101W 15 1W 110 1W ivv lib 00 EtI X16 X4 X11 Floor 4 X11 X5 X16 X16 X4 X11 X2 Floor 3 X�30 1W y15 1W 110 X14 X4 X11 Floor 2 1W 110 1W 15 1W110 1W 1101W v.15 1W 1101W X12 X4 X11 Floor 1 2W 75 WP 1W X2 ljX2 0 15 1 X10 X4 75 1W 15 1W 30 1W 15 2W 75 1W v 30 2W 75 1W 15 1W 30 1W ' 30 1W ir 15 1W tyr.30 1If,W 30 1W 15 1Wir3 W 01 30 1W X2 c 0 X4 X4 X2 X2• X5 X2 0 1 0 X9 AM P2 30 AMP1 1 SLA Batteries ki% 44 co Q 41f cc %1•4.a) 0 J V ) O 0) M N O CO 0 L _0 0 U a) 0 E 0 0 E (l3 a) 0 Drawn Bv: EJB Checked By: JPJ Job #: 1903 Revisions: # Date Revision Notes 0 2018/12/26 Original Drawing 1 2019/04/23 Changes for Smoke Control / HVAC Coordination 2 2019/05/08 Device relocations per Owner 3 4 5 6 7 8 9 10 11 12 Engineers Stamp: Drawing/Document prepared by: Ephriam J. Bistline NICET Certification No. 136272 Fire Alarm Systems - Level IV Certification Expires: 05/01/2019 This Drawing is the exclusive Property Of Reliance Electric, and was prepared for the exclusive use of Reliance Electric and its affiliates, for the services performed by Reliance Electric. No use, reproduction or duplication of this drawing or associated documents, in part or whole may be made without the written consent of Reliance Electric. This Drawing does not constitute an engineers or architects aoproval but is considered a shoo drawing for installation purposes of Reliance Electric. Sheet Number: FA -3 Fire Alarm Notification Riser Diagrams Riser Notes 1 All smoke control circuit cabling shall be 2 -hour fire rated cable enclosed in metallic raceway. Raceway provided and installed by Electrical Contractor. 2. All SLC circuit cabling shall be MC cable listed for use as fire alarm cabling. 3. All fire alarm control/monitor modules for units/dampers on roof shall be suitably protected from the weather. This shall be accomplished by either providing a weatherproof enclosure or installing the devices inside the building. 4. All HVAC equipment / sensors will be provided and installed by others. 5. Current transformers and switches required for HVAC control and monitoring for smoke control functions will be provided and installed by others. 6. Fire alarm contractor to coordinate with all other contractors involved to ensure all smoke control systems and devices will function properly with provided equipment. 7. Fire alarm duct smoke detectors will be provided and installed by fire alarm contractor. 8. Coordinate with mechanical smoke control drawings to ensure all required functions are performed. Smoke Control Riser Diagram SEF -1 FLOOR 5 FLOOR 4 FLOOR 3 FLOOR 2 C/) 0 FLOOR 1 Typical Fire/Smoke damper with open and close confirmation switches. Provided and installed by others. 1200 12011 120V (By EC) 120V (By EC) Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit SLC Circuit 18/2 MC Cable Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 120V (By EC) 120V (By EC) Corridor Makeup Air 120V 120V SLC Circuit 18/2 MC Cable Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 120V (By EC) 120V (By EC) 120V 1200 SLC Circuit 18/2 MC Cable Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 120V (By EC) 120V (By EC) 120V 120V SLC Circuit 18/2 MC Cable Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 120V (By EC) 120V (By EC) 1200 South Wing Power From Disconnect VFD)— (By EC) Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 12011 1200 Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 120V (By EC) Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 120V (By EC) SPF -1 ( CT ) ( AF) Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 120V (By EC) ,200 Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 120V (By EC) HVAC Shaft 1200 Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 120V (By EC) 1200 SLC Circuit 18/2 MC Cable Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 120V (By EC) Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit Motorized door for corridor smoke exhaust makeup air Elevator Relief Damper No pressurization in elevator hoistway. Elevator Alternate Recall Floor Elevator Primary Recall Floor 120V (By EC) AHU-1 SEF -3 Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 1200 1201 00 120V (By EC) 1200 Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 120V (By EC) 1200 Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 120V (By EC) 1200 Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 120V (By EC) East Wing Power From Disconnect { VFDj-- (By EC) Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit SPF -2 C CT ) Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 120V (By EC) Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit SO AF ) z z 1200 Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 120V (By EC) 1200 Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 120V (By EC) CORRIDOR 120V (By EC) STAIR #1 ELEVATOR Makeup air intake for corridor smoke exhaust system Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 120V (By EC) Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit SLC Circuit 18/2 MC Cable Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 1200 SEF -2 (9 120V (By EC) 120V SLC Circuit 18/2 MC Cable Smoke Control SLC Circuit 18/2 Cl Rated Cable enclosed in metallic conduit 120V (By EC) 1200 SLC Circuit 18/2 MC Cable Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 120V (By EC) 1200 SLC Circuit 18/2 MC Cable Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 120V (By EC) 1200 STAIR #2 SLC Circuit 18/2 MC Cable Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 120V (By EC) 1200 CORRIDOR >> -0 CI) CCS 0 a.) C) CO 0 1u (t) 41: t) (tub ul N i) (7 Co CD 0 LC) C3") LC) LO O 9 C3) C) N 00 0 E2 O 0 N C a) 0 E O V E Co a) a) U C co a) CD COLC) N C3) d' CD N awn Bv: EJB Checked By: JPJ Job*: 1903 Revisions: # Date Revision Notes 0 2018/12/26 Original Drawing 1 2019/04/23 Changes for Smoke Control / HVAC Coordination 2 2019/05/08 Device relocations per Owner 3 4 5 6 7 8 9 10 11 12 Engineers Stamp: Drawing/Document prepared by: Ephriam J. Bistline NICET Certification No. 136272 Fire Alarm Systems - Level IV Certification Expires: 05/01/2019 GrG_ This Drawing is the exclusive Property Of Reliance Electric, and was prepared for the exclusive use of Reliance Electric and its affiliates, for the services performed by Reliance Electric. No use, reproduction or duplication of this drawing or associated documents, in part or whole may be made without the written consent of Reliance Electric. This Drawing does not constitute an engineers or architects ennrnval but is cnnsirierPri a shun drawinn for installation purposes of Reliance Electric. Sheet Number: FA -4 Smoke Control Riser Diagram II Pool Equip. IttlXtf/R 1.0.51011..1.2f i Pool/Spa (1) Pool HVAC Control relay/monitoring of outside air intake for smoke I exhaust from corridors. Vestibule sC H \XX PH jX PH -1 fUX DiR AUX PWR rr Washroom mu imul1111 moN,C BEE NMI/. ex.; as.11-1.1% Itor SLCI SLCI 0 5151 !Eh Fitness SLCI SID 0 oor 2 0 SLCI PBX / Server / Tel SICI,SLCI SLCI 0 Tele Conf. SIC lkhJ SID AUX IVR XXX Fa 5151 SID AUX LIWLI Hi OLinen S oom WAI.11 E ( EP Floor 2 CC1 Elev. Eqip. j AIM 04 Elevevator Lobby SLCI II1A3 4:D F PLICILE F -PHONE SLCI 1:1114 CE Motorized door to open upon activation of corridor smoke exhaust system. Door and motor supplied and installed by others. CE PPC-c3PPP 0 Bar rNrr / v I 11_1 SLCI Bar Storage —74,1 SLCI HVAC Fi4AAP • Unisex RR— Break Room Sales Office SC flk SIC H SLCI FSCP I FACP1 FCC r o\) LE Studib Q 28 1-Dx Ice AUX MILLI AUX SC ' 0 SC 1 rj 5151 Mechanical ( Laundry Room SLCI 11 SC" ------S; La - es. '1 I Stidlo K seeSB Q ,t ! 0 1111 1 ,c 0? , , L 1-1 Lt, L \ II XX MIX XXX Ila - 7 4, i ! 1 00 NO Main Fire Sprinkler Flow/Tamper and Fire Pump monitor modules. Coordinate with Fire Sprinkler contractor. Electrical SLCI IL Nome • 0 SIC' 1 E E Studio ,00 Studio K ADA RIS 136 SI -4_ F II 1 , i A SC , SC , , SC SC --1--, '—'' SC - r S LIt — Corridor IC2 -1 i 1 :IX 'Irak Li 0 SB —7 A fire alarm printer will be provided near FACP1 in the Fire Command Center. SLCI SC SLCI GM SICF _J SID Corridor i Womens Jr k?i Mens 00 SC SC 0 0 SICI SLCI Reception CE Storage SC SC SC ru Floor 2 CM 5151 Luggage Re -Store a ID Breakfast ID U. I Vestibule ,72, F oor 2 Kitchen ID EMI SLCI 1:21- 1:11I SLCI Floor 2 rtti I I T 1 I I I I I I I I 1 1 I I .iStair #1 I 1 I I I I! I I I I I I I 1 I , I 1 I ST -1 Meeting AV fl 1 -Bed 129 I SB 0 SICI 0 0 III 1=7"' SID -.41-1.11111"- an 0. I: 0 ICI 1,38 IMP 71 F. 0 r A XX -K SB SICI Ole SB nn, Standa SC AUX MIX 0 1 4 • Studio K 131 NORTH Studio K 133 5,D rTh 1rTn D SBL__F. tl t1 'r I tandard K 142 Floor 2 UX tt Floor Da) Studio K 135 Standard K 137 Floor 1 SLC and Smoke Control Plan SCALE: 1/8" = 2' 4' 8' 16' 32' ST -2 SB n 11=7,1 i0 .4,•••• cm° 1 1 1 SB SLCI Floor 2 Standard K 139 CI] Standard ADA RIS'LT±F SB 4040 SB Studio QQ ADA 141 SIC ,TET 0 o "0 08 SLCI Corn ons Suit ADA INF 143 Drawing Prepared By: awn By: EJB Checked By: JPJ Job #: 1903 Revisions: Date Revision Notes 2018/12/26 Original Drawing 1 2019/04/23 Changes for Smoke Control / HVAC Coordination e7 2019/05/08 SID 3 4 5 6 i Ali' 8 SID AUX IVR XXX Fa 5151 SID AUX LIWLI Hi OLinen S oom WAI.11 E ( EP Floor 2 CC1 Elev. Eqip. j AIM 04 Elevevator Lobby SLCI II1A3 4:D F PLICILE F -PHONE SLCI 1:1114 CE Motorized door to open upon activation of corridor smoke exhaust system. Door and motor supplied and installed by others. CE PPC-c3PPP 0 Bar rNrr / v I 11_1 SLCI Bar Storage —74,1 SLCI HVAC Fi4AAP • Unisex RR— Break Room Sales Office SC flk SIC H SLCI FSCP I FACP1 FCC r o\) LE Studib Q 28 1-Dx Ice AUX MILLI AUX SC ' 0 SC 1 rj 5151 Mechanical ( Laundry Room SLCI 11 SC" ------S; La - es. '1 I Stidlo K seeSB Q ,t ! 0 1111 1 ,c 0? , , L 1-1 Lt, L \ II XX MIX XXX Ila - 7 4, i ! 1 00 NO Main Fire Sprinkler Flow/Tamper and Fire Pump monitor modules. Coordinate with Fire Sprinkler contractor. Electrical SLCI IL Nome • 0 SIC' 1 E E Studio ,00 Studio K ADA RIS 136 SI -4_ F II 1 , i A SC , SC , , SC SC --1--, '—'' SC - r S LIt — Corridor IC2 -1 i 1 :IX 'Irak Li 0 SB —7 A fire alarm printer will be provided near FACP1 in the Fire Command Center. SLCI SC SLCI GM SICF _J SID Corridor i Womens Jr k?i Mens 00 SC SC 0 0 SICI SLCI Reception CE Storage SC SC SC ru Floor 2 CM 5151 Luggage Re -Store a ID Breakfast ID U. I Vestibule ,72, F oor 2 Kitchen ID EMI SLCI 1:21- 1:11I SLCI Floor 2 rtti I I T 1 I I I I I I I I 1 1 I I .iStair #1 I 1 I I I I! I I I I I I I 1 I , I 1 I ST -1 Meeting AV fl 1 -Bed 129 I SB 0 SICI 0 0 III 1=7"' SID -.41-1.11111"- an 0. I: 0 ICI 1,38 IMP 71 F. 0 r A XX -K SB SICI Ole SB nn, Standa SC AUX MIX 0 1 4 • Studio K 131 NORTH Studio K 133 5,D rTh 1rTn D SBL__F. tl t1 'r I tandard K 142 Floor 2 UX tt Floor Da) Studio K 135 Standard K 137 Floor 1 SLC and Smoke Control Plan SCALE: 1/8" = 2' 4' 8' 16' 32' ST -2 SB n 11=7,1 i0 .4,•••• cm° 1 1 1 SB SLCI Floor 2 Standard K 139 CI] Standard ADA RIS'LT±F SB 4040 SB Studio QQ ADA 141 SIC ,TET 0 o "0 08 SLCI Corn ons Suit ADA INF 143 Drawing Prepared By: awn By: EJB Checked By: JPJ Job #: 1903 Revisions: Date Revision Notes 2018/12/26 Original Drawing 1 2019/04/23 Changes for Smoke Control / HVAC Coordination 2 2019/05/08 Device relocations per Owner 3 4 5 6 7 8 9 10 11 12 Engineers Stamp. Drawing/Document prepared by: Ephriam J. Bistline NICET Certification No. 136272 Fire Alarm Systems - Level IV Certification Expires: 05/01/2019 -- Z This Drawing is the exclusive Property Of Reliance Electric, and was prepared for the exclusive use of Reliance Electric and its affiliates, for the services performed by Reliance Electric. No use, reproduction or duplication of this drawing or associated documents, in part or whole may be made without the written consent of Reliance Electric. This Drawing does not constitute an engineers or architects approval but is considered a shoo drawina for installation purposes of Reliance Electric. Sheet Number: FAMIMIMI05 Floor 1 SLC Smoke Control Plan Standa StandaV Standar mmons rro i (u SB II 1 SB r A r SLC2 SLC2 ® Roof Floor 3 44 Floor 1L i ii Floor 3 �. Floor 1 2nd Floor Fire Sprinkler FlowPFamper monitor. Floor 3 SLC2 Ali ro SLC2 SLC SLC2 Stair #2 Sta dard K ommons Suite Floor 1 1 J Floor 1 Studio QQ I Studio QQ 1 -Bed 1 -Bed 229 Studio K Elev. Lobby Studio QQ St dio QQ Studio QQ Studio QQ Studio K Studio K SLC2, N Studio K Studio K 2']8 Studio K SLC2 SLC2 StandarK dard K Floor Floor 3 Stair #1 OOH L SLC2 Floor 1 J 231 NORTH Studio K 233 Studio K 235 Standard K 237 Floor 2 SLC and Smoke Control Plan SCALE: 1 /8" =1' V 2' 4' 8' 16' 32' ca Q) LCo`V W ) 0) C V a Lf) O 1 ) M N Q3 O a) C° O VJ c O co O Co.U rt al - LO'^ ` LT ♦ / C r awn Bv: EJB Checked By: JPJ Job #: 1903 Revisions: # Date Revision Notes o 2018/12/26 Original Drawing 1 2019/04/23 Changes for Smoke Control / HVAC Coordination 2 2019/05/08 Device relocations per Owner 3 4 5 6 7 8 9 10 11 12 Engineers Stamp: Drawing/Document prepared by: Ephriam J. Bistline NICET Certification No. 136272 Fire Alarm Systems - Level IV Certification Expires: 05/01/2019 This Drawing is the exclusive Property Of Reliance Electric, and was prepared for the exclusive use of Reliance Electric and its affiliates, for the services performed by Reliance Electric. No use, reproduction or duplication of this drawing or associated documents, in part or whole may be made without the written consent of Reliance Electric. This Drawing does not constitute an engineers or architects approval but is considered a shoo drawing for installation purposes of Reliance Electric. Sheet Number: FA Floor 2 SLC & Smoke Control Plan dard K -Stan4 rd K 342 tandard K Corridor SLC3 SLC3 Floor 2 Floor 4 Floor 3rd Floor Fire Sprinkler Flow/Tamper monitor. Floor 2 Stand • rd K Floor 4 Stair #2 Stan•ard K udio QQ DH t Studio QQ SLC3 325 Studio QQ 327 1 -Bed 329 Studio K 331 Elev. Lobby 319 Floor 2 St dio QQ Studio QQ H • _ Studio QQ Studio QQ ADA TS Studio K Studio K 313 1 St dio QQ SLC cabl io and from thFACP shall be r9uted no less than mart. Studio K SBO SLC3 00 ri- o 00 St Studio K Studio K 0 101 SLC3 ice- St- dard K Stand • d K Floor Floor 2 Stair #1 SLC3„ Floor -2 lo; NORTH Studio K 333 335 Floor 3 SLC and Smoke Control Plan SCALE: 1/8" = 1' V 2' 4' 8' 16' 32' 0 04u O d M N ▪ O O r n��-o c o co O ▪ U co 4-; ▪ i (▪ D 0 E O U E I) U co On coco N 0) O awn Bv: EJB , Checked By: JPJ Job #: 1903 Revisions: # Date Revision Notes 0 2018/12/26 Original Drawing 1 2019/04/23 Changes for Smoke Control / HVAC Coordination 2 2019/05/08 Device relocations per Owner 3 4 5 6 7 8 9 10 11 12 Engineers Stamp: Drawing/Document prepared by: Ephriam J. Bistline NICET Certification No. 136272 Fire Alarm Systems - Level IV Certification Expires: 05/01/2019 This Drawing is the exclusive Property Of Reliance Electric, and was prepared for the exclusive use of Reliance Electric and its affiliates, for the services performed by Reliance Electric. No use, reproduction or duplication of this drawing or associated documents, in part or whole may be made without the written consent of Reliance Electric. This Drawing does not constitute an enaineers or architects annrnval but is considered a shop drawinn for installation purposes of Reliance Electric. Sheet Number: FA -7 Floor 3 SLC & Smoke Control Plan r Standar Standard Standard 81.C4 SLC4 'tt 070 SB CD! :;-St 4 ;; tL SB 1 L;11 SB SB Corridor Iti ;I 7 !Li 0 0 l 1 i I i I 1 : E LI, S E---- 0 a: 0 J q" z...._. , \ L j ,i r----- ; 1 H ; 11 n 1 1 n L ...._..... --i--;i_l_J}.J) 1 _ J I __ i J , q 7 [.---7 il / ri / .---; ____.---/ II I 1 a ___ / ' I ( ['.- '1__. - 1 L -I J [-- -, I— _ - E.: Engineer's Office Floor 5 SLC4 SLC4 SLC4 SLC4 SLC4 SLC4 Floor 5 Floor 3 I nL ij Floor 3 AMP7,8 FACP2 Linen FAPP12 FAPP13 FAPP14 FAPP15 0 0 0 0 4th Floor Fire Sprinkler tramper monitor. Floor 5 SLC4 SLC4 SB Floor 3 ard Floor 3 Stud'o tidio K Stair #2 tan ard K 21! Elev. Lobby SLC4 7+41-- [C4 V I Floor 5 Studio QQ tudio QQ S udio QQ I 416 Studio QQ 4 H, 1LJ SLC4 B ri 00 tudlo K Li ii LL = Studio K Studio QQ 425 Oe SB r SLC4 St 4 1=0 j 00 171 Studio K 10 0 4 Studio K Studio K SLC4 SLC4 Standard K 405 FAPP1 NAC4 Stair #1 Floor 5 !\\ 402 1 -Bed Studio QQ 427 1 -Bed 429 NORTH Floor 4 SLC and Smoke Control Plan SCALE: 1/8" = 2' 4' 8' 16' 32' -0 co a) L.. 0) CL CO a LO 0!) Ca, Co 0 CO s- 0 0 a) a) a E 0 E Co a) a) co 1.12 c:D CO C\1 0) "cr 0 C\I awn By: EJB Checked By: JPJ Job #: 1903 Revisions: # Date Revision Notes o 2018/12/26 Original Drawing 1 2019/04/23 Changes for Smoke Control / HVAC Coordination 2 2019/05/08 Device relocations per Owner 3 4 5 6 7 8 9 10 11 12 Engineers Stamp: Drawing/Document prepared by: Ephriam J. Bistline NICET Certification No. 136272 Fire Alarm Systems - Level IV Certification Expires: 05/01/2019 Z.-- ..._..._...?-- This Drawing is the exclusive Property Of Reliance Electric, and was prepared for the exclusive use of Reliance Electric and its affiliates, for the services performed by Reliance Electric. No use, reproduction or duplication of this drawing or associated documents, in part or whole may be made without the written consent of Reliance Electric. This Drawing does not constitute an Pnnin pa rq nr =rnhitarste annrnval hitt ie rrincirlearcal n ehnn rirowinn for installation purposes of Reliance Electric. Sheet Number: FA Floor 4 SLC Smoke Control Plan �tudio'QQ 528 ndard 1 -Bed: Corridor Roof Guest Laundry Floor 4 Floor 4 SLC5 SITS SLC5 i SLC5 FAPP19 NAC4 nr-'r- L UNC {PHONE. a' I I C Floor 4 44 r FACP2 1 SLC cables to and J --from-the FACP shalte_routed'no 9iessth ) 6' apart. Linen FAPP16 FAPP17 FAPP18 FAPP19 Floor 4 audio 1 -Bed Studio Stand St-ndard K Stair #2 F -PHONE Elev. Lobby Floor 4 St dig QQ Studio Q 1 i Studio QQ Studio K Studio QQ Sttrdfo K Studi Sta dard K Standar s K Floor Stair #1 Floor 4 SLC5 Floor 4 li SB NORTH Floor 5SLC and Smoke Control Plan SCALE: 1/8" =1' 2' 4' 16' 32' (1) E 0 0. t) Ico Ck L. -F5 >,. 03 44 in c CO t) o) 92 co • d) -16 o W co Co 65,22 zCU Wth CO o (;I co O a) h. 2 V, iN 0 o �aN awn Bv: EJB Checked By: JPJ Job #: 1903 Revisions: # Date Revision Notes 0 2018/12/26 Original Drawing 1 2019/04/23 Changes for Smoke Control / HVAC Coordination 2 2019/05/08 Device relocations per Owner 3 4 5 6 7 8 9 10 11 12 Engineers Stamp: Drawing/Document prepared by: Ephriam J. Bistline NICET Certification No. 136272 Fire Alarm Systems - Level IV Certification Expires: 05/01/2019 This Drawing is the exclusive Property Of Reliance Electric, and was prepared for the exclusive use of Reliance Electric and its affiliates, for the services performed by Reliance Electric. No use, reproduction or duplication of this drawing or associated documents, in part or whole may be made without the written consent of Reliance Electric. This Drawing does not constitute an engineers or architects aooroval but is considered a shoo drawina for installation purposes of Reliance Electric. Sheet Number: FA -9 Floor 5 SLC Smoke Control Plan r L Outside Air Supply Shaft to Corridors 0 U [ AHU-1 0 Floor 5 Floor 5 Elevator Hoistway Vent Damper See Smoke Control Riser (FA -4) for device functions. Coordinate with mechanical smoke control drawings and mechanical contractor on to ensure all required smoke control functions are performed. rei 1 00 Fel 00 See Smoke Control Riser (FA -4) for device functions. SPF -1 RTU -1 Floor 5 Floor 5 Coordinate with mechanical smoke control drawings and mechanical contractor on to ensure all required smoke control functions are performed. Floor 5 SG Floor 5 J SEF -1 1 0 0 Floor 2 SEF -3 sc..-:->• Floor 5 H 1 0 rTh 0 RTU -2 Floor 5 SPF -2 Floor 5 0 Floor 5 sc See Smoke Control Riser (FA -4) for device functions. Coordinate with mechanical smoke control drawings and mechanical contractor on to ensure all required smoke control functions are performed. ci SEF -2 NORTH Roof SLC and Smoke Control Plan SCALE: 1/8" = 1' ' 4' 8' 16' 32' a) a) Co Co 0 0) 9 0) CN Co 0 C:3 Co 00 a) a) 0 E 0 E a) 0 a) CO a) Lr) Co CN 0) wd- t• C:) CN awn By: EJB Checked By: JPJ Job #: 1903 Revisions: # Date Revision Notes 0 Original Drawing 1 220011981/01421/2236 Changes for Smoke Control / HVAC Coordination 2 2019/05/08 Device relocations per Owner 3 4 5 6 7 8 9 10 11 12 Engineers Stamp: Drawing/Document prepared by: Ephriam J. Bistline NICET Certification No. 136272 Fire Alarm Systems - Level IV Certification Expires: 05/01/2019 --T,L------- Z- This Drawing is the exclusive Property Of Reliance Electric, and was prepared for the exclusive use of Reliance Electric and its affiliates, for the services performed by Reliance Electric. No use, reproduction or duplication of this drawing or associated documents, in part or whole may be made without the written consent of Reliance Electric. This Drawing does not constitute an enoineers or architects aooroval but is considered a shoo drawing for installation purposes of Reliance Electric. Sheet Number: FA I 0 Roof SLC Smoke Control Plan L Studio QQ 128 130 4.- 1W hA [11 11' Studio K 13 Studi9 )34 SB NAE4 tMC4 SB 110 1w ; 1 * NAC 041t SB NACI // 15 Wh• SPKR ; LI 0 '0° 2W 75 TWP SPKR SPKR 7 2W 5wp .441.111 IgG3 'AIM—. " —JILL lam NAC3 SPK SPKR Washroom 7' Hi 75 1W Fitness E- g 75 1W 11 arco3.m PBX/11 NAC 3 ( SPKR NAC3 Ice SPKR NAC3 Ai? 2 SPKR NAC3 SPKR NAC3 SPKR NAC3 LAI 11 SPKR NAC3 0:! f ; I SP Studio K ADA RIS 136 2Z1 Standar Standard ADA RIS a 144 =TN NAC4 t wvoio SPKR L SPKR NAC3 Corridor SPKR NAC3 SPKR NAM SPKR NAC3 U SPKR SPKR 0, LI JL 1 1 11 j SPKR NAC3 SPKR NAC3 ( SPKR ss----SPKR NAC3 jL SPKR LI NAL'3 SPKR NA3 SPKR SPKR NAC3 SPKR SPKR Server/Tel SPKR , SPKR NAC RAC NAC3 NAC3 E-ve or ob NAC3 1W FAPP1 NAC2 Sales SPKR 15 1w 111 tACP1 AC2-- NAC2 SPKR SPKR Lobby ( See FA- .2 for smok detector coverage in the. bb u SPKR F / 1 1 v I 15 1W NAC SPKR Bar Storage 30 30 Mens Storage SPKR SPKR NACI SPKR NACI Meeting F -F77771717177-11 I I I I I II II II 11 Stair #1 ST -1 ! 1 I _1 L Vestibule 11 AV SPKR NAM c-3 30 AC3 Mechanical Electrical NAE3 30 00 1W MP1 SPKR1 FAPP1 NAC3 1 -Bed 129 Studio K 131 Studio K 133 Floor 1 Notification Studio K 135 Standard K 137 NORTH SCALE: 1/8" = 1' V .4.M117 v 2' 4' 8' 16' 32' Sta r #2 CO) NAC4 NAC4 AD Commons Suite ADA 4-1 143 °a— Standard K 139 Studio QQ ADA 141 -o CO 0 • awn By: EJB Checked By: JPJ Job #: 1903 Revisions: Date Revision Notes o 2018/12/26 Original Drawing 1 2019/04/23 Changes for Smoke Control / HVAC Coordination 2 2019/05/08 Device relocations per Owner 3 4 5 6 7 8 9 10 11 12 Engineers • Stamp: Drawing/Document prepared by: Ephriam J. Bistline NICET Certification No. 136272 Fire Alarm Systems - Level IV Certification Expires: 05/01/2019 ---- Z This Drawing is the exclusive Property Of Reliance Electric, and was prepared for the exclusive use of Reliance Electric and its affiliates, for the services performed by Reliance Electric. No use, reproduction or duplication of this drawing or associated documents, in part or whole may be made without the written consent of Reliance Electric. This Drawing does not constitute an ermineers or a mhitents A nnmval hid- ic nnneiriarari a chnn riroutinn for installation purposes of Reliance Electric. •.• a GA vlif II IU Sheet Number: Floor 1 Fire Alarm Notification Plan —r Standa Stand Standar mmons NAC4 NAC4 rr ILOJj rrol .o ,.,.----1SPKR � 110 ;ao � • CD 1W NAC4 COOSB NAC4 ,1d FAPP7 NAC4 NAC4 110 110 IAC2 AC2 HAD AG2 AC2= - -SPKR > O r.sPKR NAC2-- NRI:? Corridor FAPP6 NAC4 NAM NAM NAC3 NAC3 NAC3 NAC3 NAC3 SPKR SPKR SPKR SPKR SPKR SPKR SPKR NAC3 NAC3 NAC3 NAC3 NAC3 NAC3 KR SPKR SPKR SPKR SPKR SPKR SPKR NAM NAC3 NAC3 NAC3 NAC3 NAC3 NACA NAC3 SPKR SPKR SPKR SPKR SPKR SPKR SPKR NAM NAC3 SPKR SPKR SPKR SPAR l AMP4 SPKR1 FAPP6 1W 15 ( NACI FAPP7 NAC3 AMP3 SPKR1 Linen SPKR -- SPKR NAC4 I% to NAC2 (o NAC4 NAC4 AC4 NAC4 -APP4 NAC3 NAC4 NAC4 ommons Suite Studio QQ Studio QQ 1 -Bed 1 -Bed 229 Studio K 231 SPAR NACI SPKR SPAR NACI NACI NACI NACI NACI SPKR.--.. Studio QQ 217 St dio QQ 110-11 No Am Lo Studio QQ Studio QQ 216 Studio K Studio K MA//w i } a 7 Studio K 209 Studio K NAM Studio K Sta dard K tandar K o NORTH Studio K 233 Floor 2 Notification SCALE: 1%8" =1' Studio K 235 Standard K 237 Standard K 0) MIME CO 0 a) 0 Ci) ) 0 J (1) J � c ; CO o"t C L N O cu 0 co N = 0 ca z awn Bv: EJB Checked By: JPJ Job #: 1903 Revisions: # r� Revision Notes 0 2018/12/26 Original Drawing 1 2019/04/23 Changes for Smoke Control / HVAC Coordination 2 2019/05/08 Device relocations per Owner NAC4 NAC4 ommons Suite Studio QQ Studio QQ 1 -Bed 1 -Bed 229 Studio K 231 SPAR NACI SPKR SPAR NACI NACI NACI NACI NACI SPKR.--.. Studio QQ 217 St dio QQ 110-11 No Am Lo Studio QQ Studio QQ 216 Studio K Studio K MA//w i } a 7 Studio K 209 Studio K NAM Studio K Sta dard K tandar K o NORTH Studio K 233 Floor 2 Notification SCALE: 1%8" =1' Studio K 235 Standard K 237 Standard K 0) MIME CO 0 a) 0 Ci) ) 0 J (1) J � c ; CO o"t C L N O cu 0 co N = 0 ca z awn Bv: EJB Checked By: JPJ Job #: 1903 Revisions: # Date Revision Notes 0 2018/12/26 Original Drawing 1 2019/04/23 Changes for Smoke Control / HVAC Coordination 2 2019/05/08 Device relocations per Owner 3 4 5 6 7 8 9 10 11 12 Engineers Stamp: Drawing/Document prepared by: Ephriam J. Bistline NICET Certification No. 136272 Fire Alarm Systems - Level IV Certification Expires: 05/01/2019 This Drawing is the exclusive Property Of Reliance Electric, and was prepared for the exclusive use of Reliance Electric and its affiliates, for the services performed by Reliance Electric. No use, reproduction or duplication of this drawing or associated documents, in part or whole may be made without the written consent of Reliance Electric. This Drawing does not constitute an enaineers or architects approval but is considered a shoo drawing for installation purposes of Reliance Electric. Sheet Number: FA -12 Floor 2 Fire Alarm Notification Plan — Stud NAC4 NAC4 dard K Standard�K i andard K NAC4 NAC3 FAPP9 NACI —41 Pi flu•t) • 11 NA NAC4 SPKR .1f1M1W' SPKR 4•WO SPKR SPKR SPKRcZ 11011RI 44 Corridor NAC2--- NAC2-- NAC2 NAC2 NACI NAC NAC2 SPKR SPKR SPKR SPKR SPKR SPKR NAC?-- NAC2 NAC2 NAG NAC NAG 1W y 15 NAC NAC2-- NAC2 NACC NAC2`— NAC2 NAC SPAR SPKR SPAR SPKR SPKR SPAR SPKR SPAR SPKR SPAR SPKR SPAR SPKR SPKR SPKR NAC2 NAC2 NAC2 NAC2 NAC2 NAC2 NAG SPKR SPKR SPKR SPAR SPAR SPKR SPKR FAPP11 NAC4 -SPAR- pity NC3 AMP1 SPKR1 l - 1W 15 !1� 1 FAPP10 NAC1 FAPP11 NAC2 AMP5 SPKR1 NAC4 NACI NAC4 FAPP8 NAC4 FAPP8 NAC1 NAC4 FAPP8 NACI NAC4 III Elev Lobb NAC2 NAC4 Stand • rd K 33! NACI NAC4 SPAR NACI SPAR NACI SPKR NACI NACI NACI NACI SPKR NAC4 Studio QQ Studio QQ Studio QQ ADA TS vipp te a a IL IJ T L3 2a CM Studio K Studio QQ 325 SB r ie 110`1W 0 ion 011W- • ■ Sttadio QQ 12— Studio K 2 2II ill IH LS Studio K FAPP9 NAC2 Studio K 308 Standard K St dard K tair #1 Studio QQ 327 1 -Bed 329 Studio K 331 NORTH Studio K 333 Floor 3 Notification SCALE: X1/8 =1' Studio K 335 2' 4' 8' 16' 32' ca no co EL) 0 0) CO 0 E 0 U E con , aW ) V J o ' ■ W ■ W 65 'V 2 L w J CES o cv COU0 4-; NCD - awn Bv: EJB Checked By: JPJ Job #: 1903 Revisions: # Date Revision Notes 0 2018/12/26 Original Drawing ! p, 2 6 Device relocations per Owner 3 4 1I im Elev Lobb NAC2 NAC4 Stand • rd K 33! NACI NAC4 SPAR NACI SPAR NACI SPKR NACI NACI NACI NACI SPKR NAC4 Studio QQ Studio QQ Studio QQ ADA TS vipp te a a IL IJ T L3 2a CM Studio K Studio QQ 325 SB r ie 110`1W 0 ion 011W- • ■ Sttadio QQ 12— Studio K 2 2II ill IH LS Studio K FAPP9 NAC2 Studio K 308 Standard K St dard K tair #1 Studio QQ 327 1 -Bed 329 Studio K 331 NORTH Studio K 333 Floor 3 Notification SCALE: X1/8 =1' Studio K 335 2' 4' 8' 16' 32' ca no co EL) 0 0) CO 0 E 0 U E con , aW ) V J o ' ■ W ■ W 65 'V 2 L w J CES o cv COU0 4-; NCD - awn Bv: EJB Checked By: JPJ Job #: 1903 Revisions: # Date Revision Notes 0 2018/12/26 Original Drawing 1 2019/04/23 Changes for Smoke Control / HVAC Coordination 2 2019/05/08 Device relocations per Owner 3 4 5 6 7 8 9 10 11 12 Engineers Stamp: Drawing/Document prepared by: Ephriam J. Bistline NICET Certification No. 136272 Fire Alarm Systems - Level IV Certification Expires: 05/01/2019 This Drawing is the exclusive Property Of Reliance Electric, and was prepared for the exclusive use of Reliance Electric and its affiliates, for the services performed by Reliance Electric. No use, reproduction or duplication of this drawing or associated documents, in part or whole may be made without the written consent of Reliance Electric. This Drawing does not constitute an engineers or architects aooroval but is considered a shun drawinn for installation purposes of Reliance Electric. Sheet Number: FA -13 Floor 3 Fire Alarm Notification Plan o QQ —� Standard NAC4 Standard NC4 NAC4 NAC4 NAC4 SPKR CCI NAC3 —1W 110 1W CCI SPKR ACI, 110 SPKR SPKR SPKR SPKR SPKR SPKR SPKR NAC2-- NAC2-- NAC2--- NACI— NAC2—NAC2NAC NAC2 SPKR SPKR SPKR SPKR SPKR NAC2 NAC2---- NACI— NAC2-- NAC2 SPKR SPKR SPKR SPKR NAC2---- NAC RAC NAC2 SPKR NAC2 SPKR NAC2 SPKR SPKR SPKR SPKR SPKR NAC2-- NACI NAC2-- NACI— RACS SPKR SPKR NAC2NAC Engineer's Office AC2 421 A \\ SPKR — - AMP7 SPKR1 AMP7,8 FACP2 FAPP12 FAPP13 FAPP14 FAPP15 FAPP15 NAC4 FAPP13 Linen 'AC1 A)4 FAPP15 NAC2 SPKR CCI SPKR CCI NAC3 4 Sta r #2 Stud Elev. Lobby SPKR NACI SPKR NACI SPKR NACI PP13 NAC4 Studio QQ tudio QQ S udio QQ Studio QQ Stud o K 414 Studio K Studio QQ 425 Sud QQ Studio K Studio K FAPP13. NAC3 Studio K Stair #1 1 -Bed Studio QQ 427 1 -Bed 429 NORTH Floor 4 Notification SCALE: 1/8" = 1' 2' 4' 8' 16' 32' CcE ■ Ez2 0 1t) ct RI 44 (I) W IZ` Y I E 0 E n� W W 0 • 111110 0 CO N O N wn Bv: EJB Checked By: JPJ Job #: 1903 la # Date Revision Notes 0 2018/12/26 Original Drawing 1 2019/04/23 Changes for Smoke Control / HVAC Coordination 2 2019/05/08 Device relocations per Owner 3 4 Sta r #2 Stud Elev. Lobby SPKR NACI SPKR NACI SPKR NACI PP13 NAC4 Studio QQ tudio QQ S udio QQ Studio QQ Stud o K 414 Studio K Studio QQ 425 Sud QQ Studio K Studio K FAPP13. NAC3 Studio K Stair #1 1 -Bed Studio QQ 427 1 -Bed 429 NORTH Floor 4 Notification SCALE: 1/8" = 1' 2' 4' 8' 16' 32' CcE ■ Ez2 0 1t) ct RI 44 (I) W IZ` Y I E 0 E n� W W 0 • 111110 0 CO N O N wn Bv: EJB Checked By: JPJ Job #: 1903 Revisions: # Date Revision Notes 0 2018/12/26 Original Drawing 1 2019/04/23 Changes for Smoke Control / HVAC Coordination 2 2019/05/08 Device relocations per Owner 3 4 5 6 7 8 9 10 11 12 Engineers Stamp: Drawing/Document prepared by: Ephriam J. Bistline NICET Certification No. 136272 Fire Alarm Systems - Level IV Certification Expires: 05/01/2019 This Drawing is the exclusive Property Of Reliance Electric, and was prepared for the exclusive use of Reliance Electric and its affiliates, for the services performed by Reliance Electric. No use, reproduction or duplication of this drawing or associated documents, in part or whole may be made without the written consent of Reliance Electric. This Drawing does not constitute an i enaineers or architects annrnval hilt is rtnnsiriarnri a chnn dr-mut/in for installation purposes of Reliance Electric. 9 Sheet Number: FA -14 Floor 4 Fire Alarm Notification Plan 4 1 -Bed e— Stuck 2 hAC4 Standa Standa Ctandard K NAC4 NAC4 110 771 1 S040 B NAC3 FAPP17 NAC2 FAPP16 FAPP16 NAC4 P16 C2 SPKR SPKR SPKR SPKR SPKR SPKR SPKR NACI NACI NACI NACI NACI NACI NACI FAPP18 NAC2 FAPP17 tAC1-- Guest Laundry SPKR SPKR SPKR SPKR SPKR SPKR SPKR SPKR , 1W 15 NACI NACI NACI NACI NACI NACI NACI MCI SPKR SPKR SPKR SPKR SPKR SPKR SPKR MCI MCI MCI MCI NACI NACI NACI SPKR SPKR SPKR SPKR SPKR SPKR SPKR NACI NACI MCI MCI MCI MCI MCI NACI L —� FAPP16 FAPP17 FAPP18 FAPP19 FAPP19 NAC4 I SPKR 0 _ ,15 SPKR AAC2 AMP9 SPKR1 PP19 NiAC1 NAC4 NAC4 NAC4 • EIa Lobbv Studio QQ 525 Studio QQ 527 SPKR AC2 SPKR NAC2 NAC2---- NAC2---- NAG .—SPKR— FAPP1 NAC4 Studio QQ Studio QQ Studio QQ 515 Studio K 1 Studio K Studio QQ 512 511 SB Studio K ADA TS Studio K 509 Studio K 'mu 10 1W I Stair #1 I 1 -Bed 529 Studio K 531 NORTH Floor 5 Notification SCALE:! 1/8" = 1' 2' 4' 8' 16' 32' Stair #2 Standard K 539 co -01) co 0 0 (I) RI 44 "A% t) YI awn By: EJB Checked By: JPJ Job #: 1903 Revisions: # Date Revision Notes 0 2018/12/26 Original Drawing 1 2019/04/23 Changes for Smoke Control / HVAC Coordination 2 2019/05/08 Device relocations per Owner 3 4 5 6 7 8 9 10 11 12 Engineers Stamp: Drawing/Document prepared by: Ephriam J. Bistline NICET Certification No. 136272 Fire Alarm Systems - Level IV Certification Expires: 05/01/2019 ilw. i This Drawing is the exclusive Property Of Reliance Electric, and was prepared for the exclusive use of Reliance Electric and its affiliates, for the services performed by Reliance Electric. No use, reproduction or duplication of this drawing or associated documents, in part or whole may be made without the written consent of Reliance Electric. This Drawing does not constitute an engineers or architer_ts annrnval hnt is r r ncirtornr1 o chnn rirn a,inn for installation purposes of Reliance Electric. Sheet Number: FA -15 Floor 5 Fire Alarm Notification Plan SOUTH WING EAST WING DESCRIPTION OF OPERATION THIS BUILDING IS EQUIPPED WITH STAIRWELL PRESSURIZATION AND CORRIDOR EXHAUST. A FIRE EVENT ANYWHERE IN THE BUILDING WILL: - ACTIVATE FULL BUILDING ALARM - ACTIVATE STAIRWELL PRESSURIZATION SYSTEMS - CLOSE ALL FIRE DOORS - CLOSE HVAC DAMPERS NOT ASSOCIATED WITH SMOKE CONTROL - ACTIVATE CORRIDOR EXHAUST ON ALL FLOORS O SYSTEM NORMAL Q ELEVATOR LOBBY SMOKE OR SMOKE DETECTOR RO HEAT DETECTOR DUCT DETECTOR OR WATERFLOW Q MANUAL STATION • POWER DISCONNECT GENERATOR RUNNING SOUTH WING CORRIDOR EXHAUST AUTO STAIR #1 PRESSURIZATION AUTO ELEVATOR HOISTWAY VENT DAMPER STAIR #2 PRESSURIZATION AUTO CLOSE ON OFF FAULT ON OFF FAULT OPEN CLOSED FAULT ON OFF FAULT 0 OPEN ® CLOSED FAULT O OPEN ® CLOSED FAULT Q OPEN ® CLOSED FAULT FLOOR CONTROL OPEN Q CLOSED ® FAULT DUCT DETECTOR FLOOR 5 CORRIDOR FLOOR 4 CORRIDOR FLOOR 3 CORRIDOR OPEN CLOSED FAULT OPEN CLOSED FAULT OPEN CLOSED FAULT OPEN ® CLOSED ® FAULT OPEN O CLOSED ® FAULT OPEN CLOSED FAULT OPEN CLOSED FAULT © OPEN ® CLOSED FAULT © OPEN ® CLOSED FAULT OPEN CLOSED FAULT FLOOR 2 CORRIDOR Elevator Alternate Recall Floor © OPEN ® CLOSED FAULT OPEN CLOSED FAULT ® OPEN ® CLOSED FAULT Motorized door for corridor smoke exhaust air intake FLOOR 1 CORRIDOR Elevator Primary Recall Floor OPEN CLOSED FAULT I 1 LVL 5 WATERFLOW 0 SMOKE DET PULL STATION ® # WATERFLOW ® 0 SMOKE DET ® LVL 4 PULL STATION ® 2 WATERFLOW ® 3 SMOKE DET ® LVL 3 PULL STATION ® 5 WATERFLOW ® 6 SMOKE DET ® LVL 2 PULL STATION ® 8 WATERFLOW ® 9 SMOKE DET ® LVL 1 PULL STATION ® DUCT DETECTOR EXHAUST AUTO FLOOR 4 CORRIDOR FLOOR 3 CORRIDOR FLOOR 2 CORRIDOR Makeup air intake for corridor smoke exhaust system FLOOR 1 CORRIDOR FAULT OPEN CLOSED O FAULT OPEN O CLOSED FAULT OPEN 0 CLOSED ® FAULT STAIR #1 ELEVATOR STAIR #2 OG OPEN ® CLOSED FAULT OPEN CLOSED FAULT EAST WING LAMP TEST (1) t) RI 44 co h W 0 E 0 U E CCS CI) !n d) � U tt) � O 22 N C() §O CO 0 � • O LC) O CO O CV 0 O a)�`' > O O CV awn Bv: EJB Checked By: JPJ Job #: 1903 Revisions: # Date Revision Notes 0 2018/12/26 Original Drawing 1 2019/04/23 Changes for Smoke Control / HVAC Coordination 2 2019/05/08 Device relocations per Owner 3 4 5 6 7 8 9 10 11 12 Engineers Stamp: Drawing/Document prepared by: Ephriam J. Bistline NICET Certification No. 136272 Fire Alarm Systems - Level IV Certification Expires: 05/01/2019 This Drawing is the exclusive Property Of Reliance Electric, and was prepared for the exclusive use of Reliance Electric and its affiliates, for the services performed by Reliance Electric. No use, reproduction or duplication of this drawing or associated documents, in part or whole may be made without the written consent of Reliance Electric. This Drawing does not constitute an i enaineers nr arnhitentc annrnval hitt ie enneiriernri m ch.,n rir.*ar,n for installation purposes of Reliance Electric. Sheet Number: FA -16 Smoke Control Panel Detail FIRE ALARM AND SMOKE CONTROL SHOP DRAWINGS FOR A NEW FACILITY: BY WEST 1 N SITE ADDRESS: 515 INDUSTRY DRIVE TUKWILA, WA 98188 PROJECT LOCATION 4 ,-.. Ccr ter, SI t,c+iwi._. i a. L ye is L tor940 t url"CLQ Ott t-. Mirr,o?•. aumrrov Stluthcenter stall. E trrq tooty�Jn.. t w..r a! ss Industry e, Tukwila, WA'98 Golden ME Cu;ry :� e e Srene rc%tiJ Yr R2-4CRengo. A. SW 34th St Ta itm `^te tit -F&G tas,Norte S_,^crto,. attic wmltret ® meti•o.,e zkaot S 180th St Yls tr aq CTe,trut C.ir BUILDING INFORMATION FLOORS: 5 SQ. FT.: 116,665 OCCUPANCY: R1 UNITS: 177 BUILDING TYPE: V-A SPRINKLERED: YES FA -5 FLOOR 1 INITIATING AND SMOKE CONTROL PLAN FA -6 FLOOR 2 INITIATING AND SMOKE CONTROL PLAN CLEFTED 0 Without Comments O As Noted in Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for cc.riformance with current City standards. Acceps e C: Abbject to errors and omissions which iLtr, t R .71.,"r. -prize violations of adopted standards and responsibility for the adequacy of desig': the designer. Additions, deletion;t ,y a vis,\ ;s to these drawings after this date will vold t} i-.rcceptano and will require a resubmittal of revised drawings kW. subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: 7-i o -l 9 By: )'1f Fire Permit Number To schedule inspections call 206-575-4407 4`4OTIC tplete- signed, T Fire Department Pre-test Oartificate must°be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result kt a Re -inspection Fee and termination of the to DRAWINGS PREPARED BY: Re/lance Lie c tric 4795 OAKLAND STREET DENVER, CO 80239 (720) 749-2850 WWW. RELIANCETEAM.COM FIRE ALARM SCOPE OF WORK FIRE ALARM AND SMOKE CONTROL SYSTEMS FOR A 5 FLOOR, 116,665 SQUARE FOOT ELEMENT HOTEL BY WESTIN. THE SYSTEM SHALL INCLUDE AUTOMATIC DETECTION PER MARRIOTT LIFE SAFETY STANDARDS AND THE INTERNATIONAL FIRE CODE, SPRINKLER MONITORING, VOICE EVACUATION, FIRE-FIGHTER TELEPHONES AND THE CONTROL AND MONITORING FOR THE PRESSURIZED STAIRWELLS AND SMOKE EXHAUST SYSTEMS AND SHALL COMPLY WITH ALL APPLICABLE CODES AND STANDARDS INCLUDING CITY OF TUKWILA CITY ORDINANCES AND THE CODE AMENDMENTS FROM CITY OF TUKWILA AND WASHINGTON STATE. PROJECT CONTACTS PAGE NO. BUILDING OWNER GENERAL CONTRACTOR ELECTRICAL ENGINEER SMOKE CONTROL ENGINEER AUTHORITY HAVING JURISDICTION TUKWILA HOTEL GROUP, LLC 1735 S 19TH AVENUE, SUITE B BOZEMAN, MT 59718 KEY CONSTRUCTION (316) 263-9515 KNKASSELMAN@KEYCONSTRUCTION.COM ROBINSON ENGINEERING, INC: 206 364-3343 6) UNITED BUILDING & ENGINEERING SVCS (425) 591-4633 BOB.LONG UNITEDBES.COM CITY OF TUKWILA FIRE MARSHAL'S OFFICE (206) 575-4407 FIREMARSHAL@TUKWILAWA.GOV Adzs-rid vj Drawing/Document prepared by: Ephriam J. Bistline NICET Certification No. 136272 Fire Alarm Systems - Level IV Certification Expires: 05/01/2019 SHEET INDEX PAGE NO. PAGE NAME COVER COVER SHEET FA -1 FIRE ALARM GENERAL INFORMATION FA -2 FIRE ALARM SLC & BAKCBONE RISER FA -3 FIRE ALARM NAC RISER FA -4 SMOKE CONTROL RISER AND DETAILS FA -5 FLOOR 1 INITIATING AND SMOKE CONTROL PLAN FA -6 FLOOR 2 INITIATING AND SMOKE CONTROL PLAN FA -7 FLOOR 3 INITIATING AND SMOKE CONTROL PLAN FA -8 FLOOR 4 INITIATING AND SMOKE CONTROL PLAN FA -9 FLOOR 5 INITIATING AND SMOKE CONTROL PLAN FA -10 ROOF INITIATING AND SMOKE CONTROL PLAN FA -11 FLOOR 1 NOTIFICATION PLAN FA -12 FLOOR 2 NOTIFICATION PLAN FA -13 FLOOR 3 NOTIFICATION PLAN FA -14 FLOOR 4 NOTIFICATION PLAN FA -15 FLOOR 5 NOTIFICATION PLAN FA -16 FIRE SMOKE CONTROL PANEL RELIANCE ELECTRIC CONTACTS DRAWINGS PREPARED BY DRAWINGS CHECKED BY RELIANCE PROJECT MANAGER EJ BISTLINE (702) 343-3674 EJ.BISTLINE@RELIANCETEAM.COM RULON MUSSER (720) 250-7675 RULON.MUSSER@RELIANCETEAM.COM RULON MUSSER (720) 250-7675 RULON.MUSSER@RELIANCETEAM.COM to • 19 '019 FOS SYMBOL LEGEND QTY SYMBOL DESCRIPTION MANUFACTURER PART NUMBER MOUNTING CONTROL / POWER PANELS 2 rFACP FIRE ALARM CONTROL PANEL KIDDE VS4-GD BACKBOX 3 19 18/2 FIRE ALARM REMOTE POWER PANEL KIDDE MIRBPSI OA BACKBOX FAPPx s SIC3 5 SLC5 SLCS FIRE ALARM REMOTE AMPLIFIER KIDDE APS10A / SIGA-AA50 BACKBOX AMPx NONE 2 NCC NAC2-- FIRE ALARM REMOTE ANNUNCIATOR PANEL KIDDE K-RLCD-C 4S BOX (FAA) INITIATING DEVICES 135 O SMOKE DETECTOR WITH STANDARD BASE KIDDE KI -PD / KI -SB 3" ROUND BOX 233 SB SMOKE DETECTOR WITH LOW FREQUENCY SOUNDER BASE KIDDE KI -PD / KI-ABLT 4S BOX 13 HEAT DETECTOR WITH STANDARD BASE KIDDE KI-HRD / KI -SB 3" ROUND BOX 4 / DUCT SMOKE DETECTOR KIDDE GSA -SD N/A 2 120V CIRCUITS** MANUAL PULL STATION KIDDE GSA -M278 1 GANG BOX F *Speaker circuits between control panels and amplifiers shall be CI Rated and enclosed in metal raceways. **120V Circuits shown for reference only. These will be supplied, installed and terminated by the electrical contractor. 3 CO CARBON MONOXIDE DETECTOR SYSTEM SENSOR CO -1224T / CO-1224TR 1 GANG BOX MONITORING / CONTROL MODULES 4 onn FIRE ALARM CONTROL RELAY KIDDE GSA -CR 1 GANG BOX 35 4H FIRE ALARM HIGH VOLTAGE CONTROL RELAY KIDDE GSA -CRH 4S BOX 12 Z SINGLE INPUT MODULE KIDDE GSA -CTI 1 GANG BOX 42 02 DUAL INPUT MODULE KIDDE GSA-CT2 1 GANG BOX 16 42 REMOTE MONITOR MODULE KIDDE GSA -RMI 2 GANG BOX 194 ® SIGNAL CONTROL MODULE KIDDE GSA-CC1 2 GANG BOX NOTIFICATION DEVICES 306 15 1w WALL MOUNT SPEAKER STROBE (CANDELA AND WATTAGE INDICATED) KIDDE G4HFWF-S7VMC 4S BOX 17 15 1W O c CEILING MOUNT SPEAKER STROBE (CANDELA AND WATTAGE INDICATED) KIDDE GCHFWF-S7VMC 4S BOX 2 vuP 15 WEATHER PROOF SPEAKER STROBE (CANDELA AND WATTAGE INDICATED) KIDDE INT-4ASW BACKBOX 19 �Q/S WALL MOUNT STROBE (CANDELA INDICATED) KIDDE EGIF-VM 1 GANG BOX 1 WP 1110 WEATHERPROOF HORN STROBE AND BACKBOX (CANDELA INDICATED) KIDDE INT-8ATW / INT-WBW BACKBOX , DEVICES FOR AUXILIARY FUNCTIONS 15 • FIREFIGHTER PHONE JACK KIDDE 6833-4 1 GANG BOX C J 29 MAGNETIC DOOR HOLDER INTERLOGIX DHF -24120C 1 GANG BOX DH 16 (FSD) FIRE / SMOKE DAMPER (SUPPLIED AND INSTALLED BY OTHERS) N/A N/A N/A WIRE LEGEND LINETYPE DESCRIPTION WIRE SIZE / NO OF CONDUCTORS JACKET JACKET COLOR CONDUIT,- GH SMOKE CONTROL CIRCUITS 18/2 2 HR CI RATED RED EMT SC SC 3 SLC CIRCUITS 18/2 MC CABLE RED NONE SLCI SLCI C3 s SIC3 SLC4 SLC4 SLC5 SLCS Y NOTIFICATION CIRCUITS 14/2 FPLR RED NONE NACI NACI NCC NAC2-- NAC3 NAC3 NAC4 NAC4 • SPEAKER CIRCUITS 16/2 SHIELDED FPLR* ORANGE NONE* SPKR SPKR 0 DATA BUS CIRCUITS 18/4 2 HR CI RATED RED EMT OHS DENS NICET Certification No. 136272 SENS Circuits 18/4 2 HR CI RATED RED EMT SE :,S Ss;, 24V AUXILIARY POWER CIRCUITS 18/2 ZIP WHITE NONE AUX PAR AUX Fi a-- 120V CIRCUITS** N/A N/A N/A N/A 12UV 120V *Speaker circuits between control panels and amplifiers shall be CI Rated and enclosed in metal raceways. **120V Circuits shown for reference only. These will be supplied, installed and terminated by the electrical contractor. INPUT / OUTPUT MATRIX Control Unit Annunciation Notification Control Smoke Control v FAPP ROUGH -IN DETAIL 0 5'-6" AFF / / / FINISHED FLOOR MOUNTING HEIGHTS CEILING LINE FRE A 42" Min 48" Max MEE 80" Min 6" 6" Min 96" Max 90" Min vir V V V I mmm 60 66" / / / FINISHED FLOOR FAPP / AMP ROUGH -IN DETAIL Power stub on left side of stud 5'-0" AFF Fire Alarm wire stub on right side of stud *Protect stubbed wires and cables from physical damage using conduit or nail and tape. / / / / / / FINISHED FLOOR FIRE ALARM GENERAL NOTES 1. Fire alarm contractor will coordinate with fire sprinkler contractor to ensure that all waterflow devices and all required valves are monitored. This includes the PIV if applicable. 2. Smoke / heat detectors located next to fire alarm control units, remote power supplies and amplifier panels shall be located directly above the panel as much as possible. 3. Ensure all smoke detectors are located not less than 36" from HVAC air vents and diffusers. 4. No smoke detectors shall be installed until after construction clean-up of all trades is complete. 5. The electrical circuit breaker for all fire alarm control panels, power supplies and amplifier panels shall be red in color, clearly marked "Fire Alarm" and a breaker lock shall be installed. 6. Magnetic Door Holder power shall be discontinued in the event of NC power loss to prevent excessive battery usage. 7. Monitor modules / control relays for outside HVAC units shall either be installed inside the building in an accessible location or in weatherproof enclosures. 8. Fire Alarm contractor shall provide a printer for the fire alarm system. APPLICABLE CODES AND STANDARDS 1. 2015 International Building Code (IBC) with Tukwila City Amendments 2. 2015 International Fire Code (IFC) with Tukwila City Amendments 3. 2016 NFPA 72 Fire Alarm and Signaling Code 4. 2017 National Electric Code (NEC) 5. Tukwila City Ordinance No. 2437 6. Tukwila City Ordinance No. 2330 7. Marriott Module 14 Life Safety Standards TERMINAL WIRING METHODS INCORRECT CORRECT DETECTOR MOUNTING DETAIL CEILING Acceptable here Top of detector acceptable within 12" of ceiling Never below here Note: Measurements shown are to the closest edge of the detector SIDEWALL Example of Proper Detector Mounting NFPA 72 2016 A.17.6.3.1.3.1 C I a E O U E co a) a) U CO c) CO N 0) CD N Drawn Bv: Checked By: JPJ Job #: 1903 A B CD Revision Notes E F GH 1 I J K L MN 3 O P Q R S T U V WX Y ZAA 8 Open Circuit 9 • • 11 12 0 Engineers Stamp: Drawing/Document prepared by: Ephriam J. Bistline NICET Certification No. 136272 Fire Alarm Systems - Level IV Certification Expires: 05/01/2019 This Drawing is the exclusive Property Of Reliance Electric, and was prepared for the exclusive use of Reliance Electric and its affiliates, for the services performed by Reliance Electric. No use, reproduction or duplication of this drawing or associated documents, in part or whole may be made without the written consent of Reliance Electric. This Drawing does not constitute an enaineers or architects anoroval but is considered a shoe drawing 1 Trouble Circuit Short 0 0 0 2 System Ground Fault • • • 3 AC Power Fail • • • 4 Fire Alarm System Low Battery • • 0 5 Device Fail 0 o • 6 Device Missing 0 • • 7 Device Out of Tolerance 0 o • 8 9 Common Area Smoke Detector 0 • 0 0 • 0 0 0 • o • 0 10 E Q Heat Detector • • • • 0 • 0 • 0 0 0 • 11 Manual Pull Station 0 • 0 0 0 0 0 0 • 0 0 0 12 1st Floor Elevator Lobby Smoke Detector 0 • 0 • 0 0 0 • • • • • 0 13 2nd - 5th Floors Elevator Lobby Smoke Detector • • o • 0 0 0 0 • 0 0 0 • 14 Elevator Hoistway Smoke Detector 0 • • • • • • 0 • • • 0 0 15 Elevator Hoistway Heat Detector 0 0 • • 0 0 0 0 o • • 0 • 16 Elevator Equipment Room Smoke Detector • • • • • • • • • • • 0 0 17 Elevator Equipment Room Heat Detector 0 0 • • 0 • • • 0 0 • 0 • 18 Fire Sprinkler Waterflow 0 • 0 0 • 0 0 0 • 0 0 • 19 20 Fire Sprinkler Valve Tamper • 0 0 21 Supervisory Guest Suite Smoke Detector 0 0 0 0 22 Duct Smoke Detector • • 0 0 23 Carbon Monoxide Detector • o 0 24 FAPP ROUGH -IN DETAIL 0 5'-6" AFF / / / FINISHED FLOOR MOUNTING HEIGHTS CEILING LINE FRE A 42" Min 48" Max MEE 80" Min 6" 6" Min 96" Max 90" Min vir V V V I mmm 60 66" / / / FINISHED FLOOR FAPP / AMP ROUGH -IN DETAIL Power stub on left side of stud 5'-0" AFF Fire Alarm wire stub on right side of stud *Protect stubbed wires and cables from physical damage using conduit or nail and tape. / / / / / / FINISHED FLOOR FIRE ALARM GENERAL NOTES 1. Fire alarm contractor will coordinate with fire sprinkler contractor to ensure that all waterflow devices and all required valves are monitored. This includes the PIV if applicable. 2. Smoke / heat detectors located next to fire alarm control units, remote power supplies and amplifier panels shall be located directly above the panel as much as possible. 3. Ensure all smoke detectors are located not less than 36" from HVAC air vents and diffusers. 4. No smoke detectors shall be installed until after construction clean-up of all trades is complete. 5. The electrical circuit breaker for all fire alarm control panels, power supplies and amplifier panels shall be red in color, clearly marked "Fire Alarm" and a breaker lock shall be installed. 6. Magnetic Door Holder power shall be discontinued in the event of NC power loss to prevent excessive battery usage. 7. Monitor modules / control relays for outside HVAC units shall either be installed inside the building in an accessible location or in weatherproof enclosures. 8. Fire Alarm contractor shall provide a printer for the fire alarm system. APPLICABLE CODES AND STANDARDS 1. 2015 International Building Code (IBC) with Tukwila City Amendments 2. 2015 International Fire Code (IFC) with Tukwila City Amendments 3. 2016 NFPA 72 Fire Alarm and Signaling Code 4. 2017 National Electric Code (NEC) 5. Tukwila City Ordinance No. 2437 6. Tukwila City Ordinance No. 2330 7. Marriott Module 14 Life Safety Standards TERMINAL WIRING METHODS INCORRECT CORRECT DETECTOR MOUNTING DETAIL CEILING Acceptable here Top of detector acceptable within 12" of ceiling Never below here Note: Measurements shown are to the closest edge of the detector SIDEWALL Example of Proper Detector Mounting NFPA 72 2016 A.17.6.3.1.3.1 C I a E O U E co a) a) U CO c) CO N 0) CD N Drawn Bv: Checked By: JPJ Job #: 1903 Revisions: # Date Revision Notes 0 2018/12/26 Original Drawing 1 2019/04/23 Changes for Smoke Control / HVAC Coordination 2 2019/05/08 Device relocations per Owner 3 4 5 6 7 8 9 10 11 12 Engineers Stamp: Drawing/Document prepared by: Ephriam J. Bistline NICET Certification No. 136272 Fire Alarm Systems - Level IV Certification Expires: 05/01/2019 This Drawing is the exclusive Property Of Reliance Electric, and was prepared for the exclusive use of Reliance Electric and its affiliates, for the services performed by Reliance Electric. No use, reproduction or duplication of this drawing or associated documents, in part or whole may be made without the written consent of Reliance Electric. This Drawing does not constitute an enaineers or architects anoroval but is considered a shoe drawing for installation purposes of Reliance Electric. Sheet Number: FA -1 Fire Alarm General Information Backbone Riser Diagram Dedicated 120V from building electrical system. Panel and circuit to be field assigned. Power Supply MIRBPS6A 1211V Dedicated 120V from building electrical system. Panel and circuit to be field assigned. SLA Batteries FAPP16 Power Supply MIRBPS6A SLA Batteries FAPP17 Power Supply MIRBPS6A 120V Dedicated 120V from building electrical system. Panel and circuit to be field assigned. SLA Batteries FAPP18 Power Supply MIRBPS6A SLA Batteries FAPP19 Floor 5 Dedicated 120V from building electrical system. Panel and circuit to be field assigned. Dedicated 120V from building electrical system. Panel and circuit to be field assigned. Power Supply SLA Batteries Dedicated 120V from building electrical system. Panel and circuit to be field assigned. VS III FACP2 SLA Batteries Power Supply MIRBPS6A 120V Power Supply MIRBPS6A SLA Batteries FAPP15 120V Dedicated 120V from building electrical system. Panel and circuit to be field assigned. Dedicated 120V from building electrical system. Panel and circuit to be field assigned. SLA Batteries FAPPB Power Supply MIRBPS6A SLA Batteries FAPP9 Power Supply MIRBPS6A SLA Batteries FAPP14 Power Supply MIRBPS6A SLA Batteries FAPP10 120V Power Supply MIRBPS6A SLA Batteries FAPP13 120V Dedicated 120V from building electrical system. Panel and circuit to be field assigned. Dedicated 120V from building electrical system. Panel and circuit to be field assigned. Power Supply MIRBPS6A SLA B-tteries FAPP11 SHS Power Supply MIRBPS6A SLA Batteries FAPP12 Sb ] Floor 4 Floor 3 Dedicated 120V from building electrical system. Panel and circuit to be field assigned. Power Supply MIRBPS6A 120V Dedicated 120V from building electrical system. Panel and circuit to be field assigned. SLA Batteries FAPP7 Power Supply MIRBPS6A SLA Batteries FAPP6 Power Supply MIRBPS6A SLA Batteries FAPP5 120V Dedicated 120V from building electrical system. Panel and circuit to be field assigned. Power Supply MIRBPS6A SLA Batteries FAPP4 Floor 2 Dedicated 120V from building electrical system. Panel and circuit to be field assigned. 121V IAMP2t— I AMP1 CS- N Power I Supply SLA Batteries FAA FAA SPKR SPKR 120V Dedicated 120V from building electrical system. Panel and circuit to be field assigned. FACP1 SLA Batteries Dedicated 120V from building electrical system. Panel and circuit to be field assigned. Connection to AES radio for off-site monitoring. Power Supply MIRBPS6A SLA Batteries FAPP1 Dedicated 120V from building electrical system. Panel and circuit to be field assigned. Power Supply MIRBPS6A SLA Batteries FAPP2 120V Power Supply MIRBPS6A SLA tteries FAPP3 Floor 1 Riser Notes 1. All smoke control circuit cabling shall be 2 -hour fire rated cable enclosed in metallic raceway. Raceway provided and installed by Electrical Contractor. 2. All SLC circuit cabling shall be MC cable listed for use as fire alarm cabling. 3. All fire alarm control/monitor modules for units/dampers on roof shall be suitably protected from the weather. This shall be accomplished by either providing a weatherproof enclosure or installing the devices inside the building. SLC and Smoke Control Riser Diagram it ©®©© 0 0 0 Oe©©0 0X2 0 0 ©a© 0®© © © O SBSB SB SB®s6 X2SB SB B X2SB ®X2 X2 ©SB 40 ©SB 0 ©SB eSB 0 ©SB 0 eSB 0 ©SB 0 eSB ® ©SB 0SB ® 0 OSB 4� ©SB ® OSB 0 � 0 OSB 0 0 OB 0 0 X3 X2 X2 X2 X2 X2 ©SB 40 ©s6 X2 eee®0SB011:1e©e X2SB X2 X2SB X2 FAPP X4 AMP ©SB a ©SB ® eSB e ® ©SB © ©SB ® e SLC5 SLC5 SLC5 ® ©SB a ©SB 40 eSB ® eSB a eSB ®©® eSB ® e eSB 40 e ® ©SB ® e ®SB 43 e eSB ® eSB a ©SB ® eSB ® ©SB i eSB ® Os s eSB ® ©SB 41# eSB ® e X2 X2 X2 X2 X2 X2 X2 X3 X2 X2 X2 X2 X2 X2 X2 gg ©S ® ©SB ® esB ® eSB ® Gk ® ©SB ©SB ® eSB ® e ® ® eSB ©SBC, ® eSB 41 e ©SB a Os ® eSB a eSB ® eSB © ® eSB © OSB ® e X3 X2 X2 X2 X2 X2 AMP SLC4 FAPP X4 SLC4 SLC4 Std::1"' FACP2 SLA Batteries SB 40 ® eSB ©SB eSB © e©CD © a ee ee © CD e © e 0 e ee®e e e e 0 ® esB ©SB X3 X2 SB®X2SB SB SB SBitSB ®s6 X2 X2 X2 X2 X2 X3SB SB SB Os ® Ow ® AB2SB ® © esB esB ® eSB a I2 a eSB O.a es,„® ©SB ® e OsB ®e ® ©SB a eSB X2 X2 X2 X2sB AMP FAPP X4 © eSB O OSB X2 X2 X2 SLC3 SLC3 SLC3 ® ©SB O OSB ©SBI OSB t3� eSB ID eSB ® fa ® ®SB a ©SB ©SB e ® ©SB ®e 4t ©SB e ® eSB e ® eSB 4� eSB a eSB 43 eSB ® eSB a eSB ® eSB ® eSB ® ©SB ® ©SB X2 X3 X2 X2 X2 X4 X3 X2 X2 SB ® eSB ® eSB ® ©B ® Os ® ©SB 40 a ®©SB ► a ©SB eSB a eSB 4t a ©SB ®e eSB ® ©SB a ©SB 43eSB ® e X2 X2 AMP JFAPP X4 0 0 ©SB ® ©SB X2 X2 X2 SLC2 SLC2 C e2 N w 0 0 ® 420 eSB eSB ® eSB ® 0SB ® ©SB 41 eSB 43e ©B © ©SB e e ®©SB 0 a tar 0SB a 0SB 0 0SB FAPP X2 SB O ©SBSB e 0 0 0 3 AMP 00ID©etre ® p X5 X24 X4 X2 X3 FAPP X4 X5 SLCI SLCI L FACP1 SIA Batteries Smoke Control Circuit Roof Floor 5 Floor 4 Floor 3 Floor 2 Floor 1 E O U E Cts a) CU U a) CD 1.0 Co N 0) ti O N rawn Bv: EJB Checked By: JPJ Job #: 1903 Revisions: Elevator Relief Date FSD` FSD FSD Damper ( FSD) FSD FSD FSO FSD Original Drawing 1 2019/04/23 Changes for Smoke Control / HVAC Coordination 2 2019/05/08 Device relocations per Owner 3 4 5 6 7 8 S 9 10 0 2 12 0 2 SC e C, 2 0 H NICET Certification No. 136272 Fire Alarm Systems - Level IV H 41-7_3747..A____ H This Drawing is the exclusive Property Of Reliance Electric, and was prepared for the exclusive use of Reliance Electric and its affiliates, for the services performed by Reliance Electric. Nouse, reproduction or duplication of this drawing or associated documents, in part or whole may be made without the written consent of Reliance Electric. This Drawing does not constitute an engineers nr architects annrnval but is considered a shop drawing H 02 a 02 ® ® ®H 0 0 02 02 02 0H ®H y 0 •® -( FSD) CS 2 H 02 0H FSD 02 OH—( FSD) OH 02 FSD 0 2 • �H - (FSD) 02 0 -( FSD) 0 • ® F SD 2 H - 02 OH--( FSD) 0 ''OH-( FSD) 0 0 -( FSD) 05 2 H Cl v 0 O -( FSD) 02 0H-( FSD) 02 OHI ` FSD) 02 0H-( FSD) 0 0 -( FSD) 2 H y LI Ll 0 0 -( FSD) 2 H 02 OH FSD 02 COH--(FSD) 0H 021---( FSD) 0 0 --( FSD) 2 H 02 0H-( FSD) •FSD 2 H 0 02 H Makeup . Damper H 2 CO 1 --1 MotodzedDoor1 02 0H FSD) SC SC Sc Sc SC SE SC SC SC SC SC Roof Floor 5 Floor 4 Floor 3 Floor 2 Floor 1 E O U E Cts a) CU U a) CD 1.0 Co N 0) ti O N rawn Bv: EJB Checked By: JPJ Job #: 1903 Revisions: # Date Revision Notes 0 2018/12/26 Original Drawing 1 2019/04/23 Changes for Smoke Control / HVAC Coordination 2 2019/05/08 Device relocations per Owner 3 4 5 6 7 8 9 10 11 12 Engineers Stamp: Drawing/Document prepared by: Ephriam J. Bistline NICET Certification No. 136272 Fire Alarm Systems - Level IV Certification Expires: 05/01/2019 41-7_3747..A____ This Drawing is the exclusive Property Of Reliance Electric, and was prepared for the exclusive use of Reliance Electric and its affiliates, for the services performed by Reliance Electric. Nouse, reproduction or duplication of this drawing or associated documents, in part or whole may be made without the written consent of Reliance Electric. This Drawing does not constitute an engineers nr architects annrnval but is considered a shop drawing for installation purposes of Reliance Electric. Sheet Number: FA -2 Fire Alarm SLC & Smoke Control Risers Floors 1-3 Notification Riser Diagram Floor 3 NAC3 NAC3 ♦ ,15 1W ,Q♦ X2 NAC3 X3 X3 X2 Power Supply NACI NAC3 Power Supply X3 NAC X2 NACI 1W 110 ©SB X11 X2 Power Supply X2 Floor 2 NACI NAC 1W NAC 1W 151W 15 1W 15 1W 30 X2 X2 A 1W 1W AC2 X2 SB X14 Power Supply MIRBPS6A $LA Batteries FAPP7 X3 NAC3 NAC3 1W110 1W 110 _ 1W X3 X2 NAC3 X3 X2 AC2 SB X11 NAC2 NAC3 Power Supply MIRBPS6A SLA Batteries FAPP6 s6 X11 X2 Power Supply MIRBPS6A SLA Batteries FAPPS Power Supply X2 NACI X2 Floor 1 Power Supply NAC 2W NACI NAC X2 1W 110 C2 411'SB X9 110 1W43, X2 NACI 1W 110 el AC2 Power Supply MIRBPS6A SLA Batteries FAPP2 15 0 1 • 0 0 ►iii 0 _ ►yL� X2 X2 X2 52W 75 1W 30 2W 75 1W 151W 30 1W15 Power Supply 2 1W I, 30 1W v 15 1W v30 1W 30 1W 15 1W v 30 2C ..� Floors 4-5 Notification Riser Diagram Floor 5 Power Supply NAC NACI X2 NAC3 NAC3 1W 110 _ 1W 110 _ 1W X2 Power Supply Power Supply NAC NAC3 NAC3 NAC3 1W 110 1W 110 1W 110 1W X3 X3 NACI NAC2— NAC2 1w 110 1W NAC3 NAC3 ♦ i15 1W NAC2 NAC2— NAC2— ..„..„(1 5 1W 110 ` X15 .♦ O\ ..y., X3 NACI X2 Power Supply MIRBPS6A SLA Batteries FAPP16 Floor 4 1W110 NAC3 NACI Power Supply X2 NAC3 fitsB X16 X2 NAC X2 X3 NAC3 NACI 1W 110 a Power Supply MIRBPS6A SLA Batteries FAPP14 X2 Power Supply MIRBPS6A SIA Batteries FAPP13 ♦ i15 1W .♦ X2 110 Power Supply Speaker Riser Diagram Floor 5 1W 110 1W 15 1W 110 X11 X6 X16 X16 X4 X11 AMP10 I AMP9I SLA Batteries Floor 4 X11 15 i:110 X5 X16 X16 X4 X11 X2 AMP8 AM P7 SLA Batteries Floor 3 X11 X5 X18 15 1W:110 1W 30 1W 1 0 o X4 X11 AMP6 AMP5 "} SLA Batteries Floor 2 X12 X4 X11 Floor 1 30 1W 5 2W' 75 1W 30 2W 75 1W .. 15 1W 30 1W 30 1W 15 1W 30 1 c C C c X4 X4c X2c X2c N 6-5 CO (130 LO C) I�- d' O 9 C) co N O co 0 0 0 a) a) 0 E 00 E Cts CU U a) LC ) CO N C) r• - (NI N ti awn Bv: EJB Checked By: JPJ Job #: 1903 Revisions: # Date Revision Notes 0 2018/12/26 Original Drawing 1 2019/04/23 Changes for Smoke Control / HVAC Coordination 2 2019/05/08 Device relocations per Owner 3 4 5 6 7 8 9 10 11 12 Engineers Stamp: Drawing/Document prepared by: Ephriam J. Bistline NICET Certification No. 136272 Fire Alarm Systems - Level IV Certification Expires: 05/01/2019 This Drawing is the exclusive Property Of Reliance Electric, and was prepared for the exclusive use of Reliance Electric and its affiliates, for the services performed by Reliance Electric. No use, reproduction or duplication of this drawing or associated documents, in part or whole may be made without the written consent of Reliance Electric. This Drawing does not constitute an enaineers nr architects annrnval hut is nnnsiriarari a shnn rirawinn for installation purposes of Reliance Electric. Sheet Number: FA -3 Fire Alarm Notification Riser Diagrams Riser Notes 1. All smoke control circuit cabling shall be 2 -hour fire rated cable enclosed in metallic raceway. Raceway provided and installed by Electrical Contractor. 2. All SLC circuit cabling shall be MC cable listed for use as fire alarm cabling. 3. All fire alarm control/monitor modules for units/dampers on roof shall be suitably protected from the weather. This shall be accomplished by either providing a weatherproof enclosure or installing the devices inside the building. 4. All HVAC equipment / sensors will be provided and installed by others. 5. Current transformers and switches required for HVAC control and monitoring for smoke control functions will be provided and installed by others. 6. Fire alarm contractor to coordinate with all other contractors involved to ensure all smoke control systems and devices will function properly with provided equipment. 7. Fire alarm duct smoke detectors will be provided and installed by fire alarm contractor. 8. Coordinate with mechanical smoke control drawings to ensure all required functions are performed. Smoke Control Riser Diagram SEF -1 FLOOR 5 FLOOR 4 FLOOR 3 FLOOR 2 FLOOR 1 Typical Fire/Smoke damper with open and close confirmation switches. Provided and i installed by others. 1211V AIM 120V (By EC) 2 120V 120V (By EC) Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit SLC Circuit 18/2 MC Cable Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 120V (By EC) 120V (By EC) Corridor Makeup Air 120V AOM 11 120V SLC Circuit 18/2 MC Cable Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 120V (By EC) 120V (By EC) 1201 120V SLC Circuit 18/2 MC Cable Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 120V (By EC) 120V (By EC) 120V 120V SLC Circuit 18/2 MC Cable Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 120V (By EC) 120V (By EC) 120V HVAC Shaft South Wing Power From Disconnect _ (VFD) - (By EC) Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 120V SPF -1 CT Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 120V (By EC) Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 120V (By EC) ( AF CM I20V Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 1 20V (By EC) 120V Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 120V (By EC) 120V Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 120V (By EC) 120V SLC Circuit 18/2 MC Cable Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 120V (By EC) Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit Motorized door for corridor smoke exhaust makeup air A\\ O Elevator Relief Damper No pressurization in elevator hoistway. Elevator Alternate Recall Floor Elevator Primary Recall Floor 120V (By EC) AHU-1 SEF -3 Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit C!) 0 120V 120V 121V SC 120V (By EC) 120V Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 120V (By EC) 120V Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 120V (By EC) 120V Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 120V (By EC) East Wing Power From Disconnect VFD)— (By EC) Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 120V (By EC) Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit SC SPF -2 CT ) ( AF) z z 120V Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 120V (By EC) 120V Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 120V (By EC) 120V (By EC) CORRIDOR STAIR #1 ELEVATOR Makeup air intake for corridor smoke exhaust system 120V (By EC) 120V Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 120V (By EC) Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit SLC Circuit 18/2 MC Cable Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 120V (By EC) 120V SEF -2 120V SLC Circuit 18/2 MC Cable Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 120V (By EC) 120V SLC Circuit 18/2 MC Cable Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 120V (By EC) 120V (oT� SLC Circuit 18/2 MC Cable Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 120V (By EC) 120V nr--1 STAIR #2 SLC Circuit 18/2 MC Cable Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 120V (By EC) 120V 0 CORRIDOR 15,1 -0 co 0 0 0) co 0 awn Bv: EJB Checked By: JPJ Job #: 1903 Revisions: # Date Revision Notes 0 2018/12/26 Original Drawing 1 2019/04/23 Changes for Smoke Control / HVAC Coordination 2 2019/05/08 Device relocations per Owner 3 4 5 6 7 8 9 10 11 12 Engineers Stamp: Drawing/Document prepared by: Ephriam J. Bistline NICET Certification No. 136272 Fire Alarm Systems - Level IV Certification Expires: 05/01/2019 E.-/ �„ - This Drawing is the exclusive Property Of Reliance Electric, and was prepared for the exclusive use of Reliance Electric and its affiliates, for the services performed by Reliance Electric. No use, reproduction or duplication of this drawing or associated documents, in part or whole may be made without the written consent of Reliance Electric. This Drawing does not constitute an enaineers or architects aooroval but is considered a shoo drawing for installation purposes of Reliance Electric. Sheet Number: FA -4 Smoke Control Riser Diagram Control relay/monitoring of outside air intake for smoke exhaust from corridors. n Studio K ADA RIS. j 136 I ✓T� Studio QQ Standa tandard K Standard ADA RIS Vestibule ti ail F -rte Pool 1 Spa Floor 2 Corridor Floor 2 Pool Equip. CO AUXiINRId 11 AUX PWR API PWR AUX PWR AUX PWR AUX PWR Washroom AUX Rift AUX MR AUX MR Aa -P AUX YAR AUX- ALX SLCI SLCI SLCI SIC Floor J Mechanical 1-7 SLCI I U Linen Room SICI SLCI SLCI Floor 2 j Elev. Equip. © t fid us Laundry Room Stair #2 Froor 2 J Main Fire Spnnkler Flow/Tamper and Fire Pump monitor modules. _ Coordinate with Fire Sprinkler contractor. Commons Suit ADA ST -2 -Bed Elevevator Lobby ❑ I Fitness F -PHONE F -PHONE FAIR NIA n L / SLCI 48,1 Unisex RR Electrical Break Room SLC! PBX I Server I Tel Sales I FSCPJ FACP i SLCI A fire alarm printer will be provided near FACP1 in the Fire Command Center. ICI Tele Conf. FCC SICI Office SC SLCI SID SLC CI 0 CIO ® co Reception SLCI SLCI Luggage Re -Store Lobby ii al Vestibule 11 CZ Corridor Bar SID Bar Storage SID HVAC Womens Eel SC SC Kitchen Motorized door to open upon activation of corridor smoke exhaust system. Door and motor supplied ( and installed by others. Floor 2 SLCI SID Floor 2 SID Storage Stair #1 I ST -1 SLCI SICI SLCI Meeting 129 Studio K 131 NORTH Studio K 133 Studio K 135 Standard K 137 Floor 1 SLC and Smoke Control Plan 2' 4' 8' 16' 32' Standard K 139 Studio QQ ADA 141 C2c33 01) o tn. -.(3 c 0 Ca 0 CD 0 43 ED - CO EJB Checked By: JPJ Revisions: # Date Revision Notes o 2018/12/26 Original Drawing 1 2019/04/23 Changes for Smoke Control / HVAC Coordination 2 2019/05/08 Device relocations per Owner 3 4 5 6 7 8 9 10 11 12 Engineers Stamp. Drawing/Document prepared by: Ephriam J. Bistline NICET Certification No. 136272 Fire Alarm Systems - Level IV Certification Expires: 05/01/2019 This Drawing is the exclusive Property Of Reliance Electric, and was prepared for the exclusive use of Reliance Electric and its affiliates, for the services performed by Reliance Electric. No use, reproduction or duplication of this drawing or associated documents, in part or whole may be made without the written consent of Reliance Electric. This Drawing does not constitute an for installation purposes of Reliance Electric. Sheet Number: FA 5 Floor 1 SLC Smoke Control Plan a), 0, A r r 0 I Ili sL2 SLC2 SE li'd. 2 -Bed ADA TS 225 I Standa Stand40 Standar mmons Corridor SLC2 r O Floor 3 Floor Floor 3 Floor SLC2 Floor 3 Stair #2 dard K ommons Suite Studio Floor 1 I -, Studio QQ 1 -Bed 225 Studio QQ 227 1 -Bed 229 Studio K 231 Studio QQ 217 St dio QQ Studio QQ Stu • io QQ Studio K Studio K L J Studio K Studio K Studio K Sta dard K o1 Floor Floor 3 DN U 2 -Bed rWM Oil Floor 1 I 1 -Bed ADA 201 NORTH Studio K 233 Studio K 235 Standard K 237 Floor 2 SLC and Smoke Control Plan SCALE: 1/8" = 1' V 2' 4' 8' 16' 32' a,t` co -o CU co W )Ea)0 Cts 0 CD sd) CO N O co L O VJ -a_ — �o O U W ,^^ \ L ♦ / O � d' D E O U E CO a) co d3 U co a) O Co N C) O N awn Bv: EJB Checked By: JPJ Job #: 1903 Revisions: Stair #1 Revision Notes 0 2018/12/26 I ST -1 1 2019/04/23 Changes for Smoke Control / HVAC Coordination 2 -Bed rWM Oil Floor 1 I 1 -Bed ADA 201 NORTH Studio K 233 Studio K 235 Standard K 237 Floor 2 SLC and Smoke Control Plan SCALE: 1/8" = 1' V 2' 4' 8' 16' 32' a,t` co -o CU co W )Ea)0 Cts 0 CD sd) CO N O co L O VJ -a_ — �o O U W ,^^ \ L ♦ / O � d' D E O U E CO a) co d3 U co a) O Co N C) O N awn Bv: EJB Checked By: JPJ Job #: 1903 Revisions: # Date Revision Notes 0 2018/12/26 Original Drawing 1 2019/04/23 Changes for Smoke Control / HVAC Coordination 2 2019/05/08 Device relocations per Owner 3 4 5 6 7 8 9 10 11 12 Engineers Stamp: Drawing/Document prepared by: Ephriam J. Bistline NICET Certification No. 136272 Fire Alarm Systems - Level IV Certification Expires: 05/01/2019 This Drawing is the exclusive Property Of Reliance Electric, and was prepared for the exclusive use of Reliance Electric and its affiliates, for the services performed by Reliance Electric. No use, reproduction or duplication of this drawing or associated documents, in part or whole may be made without the written consent of Reliance Electric. This Drawing does not constitute an engineers or architects aooroval but is considered a shop drawing for installation purposes of Reliance Electric. Sheet Number: FA Floor 2 SLC & Smoke Control Plan tudio Qa Stan4ard Standard K c"tandard K Corridor SlC3 5E3 Floor 2 Floor 4 Floor 4 Floor Floor 2 Stand rd K Floor 4 3rd Floor Fire Sprinkler Flow/Tamper monitor. Stan•ard K Floor 4 Studio QQ Elev. Lobby Floor 2 St dio QQ St dio QQ Studio QQ Studio QQ ADA TS Studio K 325 dio QQ Studio K C3 SI G3 Studio K Studio K Studio K 308 SLC31 �SLC3 St-ndard K Stand- d K Floor 2 Stair #1 Floor -2 , SB dor 4 Studio QQ 1 -Bed 327 329 Studio K 331 NORTH Studio K 333 Studio K 335 Floor 3 SLC and Smoke Control Plan SCALE: 1 /8" = 1' 2' 8' 16' 32' u u C L LO 15: M 4 L.0 cs -072 t W .4.6 04 n 6Ni, coCD_ 65 "C3ED. 'CI EC-5CZ 0 0) Et?, U Ot Q) Q E 0 U E Co a) a) Co 13. Q L.c) co N 0) N wn Bv: EJB Checked By: JPJ Job #: 1903 Revisions: # Date Revision Notes 0 2018/12/26 Original Drawing 1 2019/04/23 Changes for Smoke Control / HVAC Coordination \VAI 2019/05/08 Device relocations per Owner 3 Stair #2 4 ST -2 5 Stan•ard K Floor 4 Studio QQ Elev. Lobby Floor 2 St dio QQ St dio QQ Studio QQ Studio QQ ADA TS Studio K 325 dio QQ Studio K C3 SI G3 Studio K Studio K Studio K 308 SLC31 �SLC3 St-ndard K Stand- d K Floor 2 Stair #1 Floor -2 , SB dor 4 Studio QQ 1 -Bed 327 329 Studio K 331 NORTH Studio K 333 Studio K 335 Floor 3 SLC and Smoke Control Plan SCALE: 1 /8" = 1' 2' 8' 16' 32' u u C L LO 15: M 4 L.0 cs -072 t W .4.6 04 n 6Ni, coCD_ 65 "C3ED. 'CI EC-5CZ 0 0) Et?, U Ot Q) Q E 0 U E Co a) a) Co 13. Q L.c) co N 0) N wn Bv: EJB Checked By: JPJ Job #: 1903 Revisions: # Date Revision Notes 0 2018/12/26 Original Drawing 1 2019/04/23 Changes for Smoke Control / HVAC Coordination 2 2019/05/08 Device relocations per Owner 3 4 5 6 7 8 9 10 11 12 Engineers Stamp: Drawing/Document prepared by: Ephriam J. Bistline NICET Certification No. 136272 Fire Alarm Systems - Level IV Certification Expires: 05/01/2019 This Drawing is the exclusive Property Of Reliance Electric, and was prepared for the exclusive use of Reliance Electric and its affiliates, for the services performed by Reliance Electric. No use, reproduction or duplication of this drawing or associated documents, in part or whole may be made without the written consent of Reliance Electric. This Drawing does not constitute an enaineers or architects aooroval but is considered a shoo drawino for installation purposes of Reliance Electric. Sheet Number: FA -7 Floor 3 SLC Smoke Control Plan j Standar Standard Standard an•ar. ADA TS ro 1 ui J SB Corridor Engineer's Office Floor 5 SLC4 SLC4 Floor 3 Floor AMP7,8 FAPP12 FAPP13 FAPP14 FAPP15 Floor 5 ®•©SB Floor 3 CDStudi Stair #2 Floor 3 SLC4 Floor 5 tudio QQ S udio QQ Elev. Lobby 419 Studio QQ Studio QQ tudio K Studio K Studio QQ 425 m Studio QQ Studio K Studio K Studio K SLC4 all rd -K SLC4 FAPP1 NAC4 or 3 Floors tair #1 Floor 5 'Floor -5 11)2 SB L t �i! Studio QQ 427 1 -Bed 429 NORTH Floor 4SLC and Smoke Control Plan SCALE. 1/8" =1' 2' 4' 8' 16' 32' C Co E2 0 E O U E CO C) CI) U CO CU CD L CO N C) N- CD CV awn By: EJB Checked By: JPJ Job #: 1903 Revisions: # Date Revision Notes 0 2018/12/26 Original Drawing 1 2019/04/23 Changes for Smoke Control / HVAC Coordination 2 2019/05/08 Device relocations per Owner 3 4 5 6 7 8 9 10 11 12 Engineers Stamp: Drawing/Document prepared by: Ephriam J. Bistline NICET Certification No. 136272 Fire Alarm Systems - Level IV Certification Expires: 05/01/2019 This Drawing is the exclusive Property Of Reliance Electric, and was prepared for the exclusive use of Reliance Electric and its affiliates, for the services performed by Reliance Electric. No use, reproduction or duplication of this drawing or associated documents, in part or whole may be made without the written consent of Reliance Electric. This Drawing does not constitute an enaineers or architects annrnval but is nnnairiararl a ChoP riraw nn for installation purposes of Reliance Electric. Sheet Number: FA -8 Floor 4 SLC & Smoke Control Plan % 4M1111111'7 tudio QqQ 528 taridard K SLC5 Corridor Roof Guest Laundry Floor 4 SLC5 5105 SLC5 i SLC5 FAPP19 NAC4 H F-PH[NE F PHfNE - 0'E ° ON Floor 4 r FACbP2 -iSLC cab es to and L from-th FACP sha Lberouted-no lessttr 6' apart. FAPP16 FAPP17 FAPP18 FAPP19 Roof Roof ® i CC1 — F PHONE F-PHBNE Elev. Lobby ra , Floor 4 a ,'io QQ I Floor 4 St dio QQ Studio Q r 1r Studio QQ Studio QQ Studio k ��r 1 105 . SLC Studio QQ I 512 5E5 ' SLC5 SLCSI J 5 IIS dard K Floor J Stair #1 U Floor 4 A SB Roof 2 H SLC5 0' Floor 4 1 5105 SB L NORTH Floor 5 SLC and Smoke Control Plan SCALE: 1/8" = 1' rl 2' 4' 8' 16' 32' Stair #2 E CD 0 ‚Jo t)t/ %111% co C k i . 0 a) U t 44 L O -2 CO _ 8,2 co .,.: Ns L. ID tb , co , a) -4CZ C:0 -a5 co O. -fes 1 aco O � 2 o opo u . . . a3 p c\I 0)�Ua) c d -0ti h- 0) C O N. W 'Cr 0 CO E2 0 awn Bv: EJB Checked By: JPJ Job #: 1903 Revisions: # Date Revision Notes 0 2018/12/26 Original Drawing 1 2019/04/23 Changes for Smoke Control / HVAC Coordination 2 2019/05/08 Device relocations per Owner 3 4 5 6 7 8 9 10 11 12 Engineers Stamp: - Drawing/Document prepared by: Ephriam J. Bistline NICET Certification No. 136272 Fire Alarm Systems - Level IV Certification Expires: 05/01/2019 This Drawing is the exclusive Property Of Reliance Electric, and was prepared for the exclusive use of Reliance Electric and its affiliates, for the services performed by Reliance Electric. No use, reproduction or duplication of this drawing or associated documents, in part or whole may be made without the written consent of Reliance Electric. This Drawing does not constitute an P_nO1r1P_P_rS nr architPrtc annrnval hilt iC ennciriarari a chnn dr -outline -1 for installation purposes of Reliance Electric. Sheet Number: FA -9 Floor 5 SLC Smoke Control Plan 1 11 ; 1 1 ! I 1 ; 1 1 • • AHU-1 Floor 5 Outside Air Supply/ Shaft to Corridors Floor 5 Elevator Hoistway Verit Damper See Smoke Control Riser (FA -4) for device functions. Coordinate with mechanical smoke control drawings and mechanical contractor on to ensure all required smoke control functions are performed. 11 0 10 0 Te7 See Smoke Control Riser (FA -4) for device functions. SPF -1 Floor 5 RTU -1 Floor 5 Coordinate with mechanical smoke control drawings and mechanical contractor on to ensure all required smoke control functions are performed. Floor 5 SC J SEF -1 H 0 0 Floor 2 41: SEF -3 Floor 5 0 R-1 ; 0 [0 RTU -2 SPF -2 0 Floor 5 Floor 5 0 See Smoke Control Riser (FA -4) for device functions. Coordinate with mechanical smoke control drawings and mechanical contractor on to ensure all required smoke control functions are performed. SEF -2 NORTH Roof SLC and Smoke Control Plan SCALE: 1/8" = 1' V AINIIIV 2' 4' 8' 16' 32' 0) co 0 E 0 E co a) 0 4-64 0) co csJ 0) c\I wn B : EJB Checked By: JPJ Job #: 1903 . Revisions: # Date Revision Notes 0 2018/12/26 Original Drawing 1 2019/04/23 Changes for Smoke Control / HVAC Coordination 2 2019/05/08 Device relocations per Owner 3 4 5 6 7 8 9 10 11 12 Engineers Stamp: Drawing/Document prepared by: Ephriam J. Bistline NICET Certification No. 136272 Fire Alarm Systems - Level IV Certification Expires: 05/01/2019 4&17 This Drawing is the exclusive Property Of Reliance Electric, and was prepared for the exclusive use of Reliance Electric and its affiliates, for the services performed by Reliance Electric. No use, reproduction or duplication of this drawing or associated documents, in part or whole may be made without the written consent of Reliance Electric. This Drawing does not constitute an enaineers or architects aooroval but is considered a shnn drawinn for installation purposes of Reliance Electric. Sheet Number: FA 1 0 Roof SLC & Smoke Control Plan • Pool / Spa Vestibule \ L Studio QQ 128 CE L I S udio K Studio K ADA RIS 136 13 ) Studio 34 tan da Standar 42 © Standard ADA RIS 144 k CC1 SB NAC -74 — SPIT SPK 1 I, I +- o °c; SPKR NAC3 I NACI * 1!—,C)L44W° , 15 11 " SPKR NAC3 SPKR NAC3 SPKR SPKR NAC3 NAC3 '079 L.) 2 01 , o :I 1WZ15 Wirt110 SPKR LI ;2.2:- i• P N ' 4 L • ti7!) I L Corridor SPKR SPKR SPKR LiJ I PKR C.= SPKR SPKR SPKR SPKR NAC3 NAC3 NAC3 NAC3 NAC3 NAC3 NAC3 SPKR NAC3 . SPKR NAC3 NAC3 SPKR Washroom/ Ice 30 0 Linen pal rdroom PBX Server I Tel SPKR SPKR NAC NAG 1WT 30 AC2--- NAC2-- NAC SPKR SPKR Tele Conf. 1W 401 RP IP See FA- .2 for sm ke detector coverage in hei.bb • Got Go G FAPP1 NAC2 Sales SPKR 15 1W Admin 00 1W LFSCPJ IZACPJ U FCC 30 1W GM Reception SPKR Corridor Bar Storage Storage SPKR 15 1W 0 8 1W 30 0 Kitchen Luggage Re -Store Vestibule f Fr ! ! I I I I ptair #1 ST -1 ! VT SPKR SPKR SPKR NACI NACI NAB Meeting AV LJ h Mechanical Q.0 a. a- < Electrical NAC3 NAC3 :4J4. 110 < 30k1W SPKR1 AMP1 N, FAPP1 NAC3 1 -Bed 129 Studio K 131 NORTH Studio K 133 Floor 1 Notification SCALE: 1/8" = 1' 135 137 111.1111=11.1=111 2' 4' 8' 16' 32' 139 NAC4 -T-3111.111 Studio QQ ADA 141 Commons Suite ADA 2143 awn By: EJB Checked By: JPJ Job #: 1903 Revisions: # Date Revision Notes o 2018/12/26 Original Drawing 1 2019/04/23 Changes for Smoke Control / HVAC Coordination 2 2019/05/08 Device relocations per Owner 3 4 5 6 7 8 9 10 11 12 Engineers Stamp: Drawing/Document prepared by: Ephriam J. Bistline NICET Certification No. 136272 Fire Alarm Systems - Level IV Certification Expires: 05/01/2019 This Drawing is the exclusive Property Of Reliance Electric, and was prepared for the exclusive use of Reliance Electric and its affiliates, for the services performed by Reliance Electric. No use, reproduction or duplication of this drawing or associated documents, in part or whole may be made without the written consent of Reliance Electric. This Drawing does not constitute an enoineers or architects anumval hilt is nnncitiorari a a Kiln rira..Ar.,,, for installation purposes of Reliance Electric. Sheet Number: FA -Il Floor 1 Fire Alarm Notification Plan Standa Standgl Standar mmons CoJ SPKR CCI FAPP7 N"C4 NAC4 NAC4 SAD I 17-7, 1' SPKR `-� �, SPKR 110 Whi FAPP7 NAC4 110 1w O©SB FAPP6 NAC4 1W 1s ( 1W ' 15 AC3 NAC3 NAC3 NAC3 NAC3 NAC3 NAC3 �7y NAC3 C / SPKR SPKR SPKR SPKR SPKR SPKR SPKR SPKR NAC3 NAC3 NAC3 NAC3 NAC3 ( 1 NAC3 NAC3 NAC3 NAC3 NAC3 NAC3 NAC3 SPKR SPKR SPKR SPKR SPKR SPKR / SPKR SPKR SPKR SPKR SPKRSPKR SPKR l; I AMP4 i SPKR1 FAPP6 1W 15 d NAC1 FAPP7 NAC3 AMP3 SPKR1 FAPP4 NAC4 NAC4 FAPP4 NAC3 NAC4 NAC4 Stair #2 ommons Suite Sta dard K Studio Studio QQ Studio QQ 1 -Bed El -v. L 1 -Bed I 229 1 SPKR SPKR SPKR NACI NACI NACI FAPP5 NAC3 NACI SPKR Studio QQ Studio QQ Studio QQ Studio QQ Studio K Studio K /1 0 a Studio K 209 Studio K Studio K FAP +5 NA 2 Stalidard K tandar1 K tair #1 ST -1 1 0 1 -Bed ' DA !0 Studio K 231 NORTH Studio K 233 Floor 2 Notification SCALE: 1/8" = 1' Studio K 235 Standard K 237 2' 4' 8' 16' 32' 5is ca (1) Co lnr�f,� 0 0) Co E2 a f',)14) cZ 4", tl Q) CC` Y' LC) LO O A-i C) M N W W 0 VJ �. 1-- 0 0 CD 0 U E 0 U E ca W U a) O,^ CO Co N C) N awn Bv: EJB Checked By: JPJ Job #: 1903 Revisions: # Date Revision Notes 0 2018/12/26 Original Drawing 1 2019/04/23 Changes for Smoke Control / HVAC Coordination 2 2019/05/08 Device relocations per Owner 3 4 5 6 7 8 9 10 11 12 Engineers Stamp: Drawing/Document prepared by: Ephriam J. Bistline NICET Certification No. 136272 Fire Alarm Systems - Level IV Certification Expires: 05/01/2019 This Drawing is the exclusive Property Of Reliance Electric, and was prepared for the exclusive use of Reliance Electric and its affiliates, for the services performed by Reliance Electric. No use, reproduction or duplication of this drawing or associated documents, in part or whole may be made without the written consent of Reliance Electric. This Drawing does not constitute an engineers or architects aooroval but is CnnsirinrP_ri a Chnn rirawinn for installation purposes of Reliance Electric. Sheet Number: FA -12 Floor 2 Fire Alarm Notification Plan NAC4 tandard K andard K NAC4 NAC4 --P41 4C1 NAGS NAC4 FAPP9 NAC1 SPAR CCI FAPP11 NAC4_, SPKR SPKR SPKR SPKR NAc3 Corridor NO NAC2--- NAG 2 SACS--- MACS NAC2 NAC2 SPKR SPKR SPKR SPKR SPKR SPKR SPKR 1w 15 +lAC2---- NAC NAC2--- NAC2– MAC NAG NAC2 NAC �W 15 NAC2— NAC2NAC2---- NAC2- NAGS-- NACI NAC SPKR SPKR SPKR SPKR SPKR SPKR SPKR SPKR SPKR SPKR SPKR SPKR SPAR SPKR SPKR C NAC2 NAC2 NAC2 NAGS NAC2 NAC2 MAC SPKR SPKR SPKR SPKR SPKR SPKR SPKR SPAR FAPP11 NAC4 ) 'L_-___-�❑ \©) FAPP11 NAC2 AMP5 SPKR1 NACI NAC4 FAPP8 NAC4 FAPP8 NACI. NAC4 NAC4 FAPP8 NAC1 NACI N C4 NACNAC NAGS NAC4 NAC4 Stand rd K NA NACI NAC4 ._ NAC4 Studio QQ 325 Studio QQ 327 1 -Bed 329 Studio K Studio K 331 SPKR SPKR SPKR NACI NACI NACI NAC4 NACI NACI ro 01 FAPP9- FAPP9 St'dio QQ Studio QQ Studio QQ ADA TS -5; Studio K 313 Studio K Sa® G Studio K FAPP9 NAC2 Studio K 308 Standard K Sta dard K 306 1W Stair #1 ST -1 1 ©sa NORTH 333 Floor 3 Notification SCALE: 1/8" = 1' Studio K 335 2' 4' 8' 16' 32' Stair #2 Studio Q Co 0 43 EL2V ) -o co co 0 LTC) V gct 0 co N O Co 0 -oCo 0 0 a) n� W 0 E 0 U E a) a) 0 0 LC) oo V J 0 N awn By: EJB Checked By: JPJ Job #: 1903 Revisions: # Date Revision Notes 0 2018/12/26 Original Drawing 1 2019/04/23 Changes for Smoke Control / HVAC Coordination 2 2019/05/08 Device relocations per Owner 3 4 5 6 7 8 9 10 11 12 Engineers Stamp: Drawing/Document prepared by: Ephriam J. Bistline NICET Certification No. 136272 Fire Alarm Systems - Level IV Certification Expires: 05/01/2019 This Drawing is the exclusive Property Of Reliance Electric, and was prepared for the exclusive use of Reliance Electric and its affiliates, for the services performed by Reliance Electric. No use, reproduction or duplication of this drawing or associated documents, in part or whole may be made without the written consent of Reliance Electric. This Drawing does not constitute an i enaineers or architects annrnval hut is r_nnciriarpri a ehnn rirn,..inr, for installation purposes of Reliance Electric. Sheet Number: FA -13 Floor 3 Fire Alarm Notification Plan NAC4 NAC4 NU C4 NAC4 4AC4 NAC4 Standar 436 NAC4 Standard Standard ADA TS SPKR ' II CO ISPKR SB SPKR L1lI f / ---NACI NAM V f.j FAPP12 i •' AC3 Corridor oil FAPP12 110 1w ®©se IL AI 4 3PKR C4---.-----.1 f SPKR SPKR SPKR SPKR SPKR SPKR NAC NAC2-- NAC2— NAC2---- NAC2— NAC SPS SPKR SPKR SPKR SPKR SPKR SPKR S KR SPKR SPKR SPKR SPKR SPKR SPKR SPKR NA 2 NAC2— NAC2— NAC2 NAC2 NAG NAC t 2 C NAC I— NAC2-•• ---NAC2'— NAC2---- NAC2----- NAC2- NAC2 SPKR SPKR SPKR SPKR SPKR SPKR SPKR NAC2-- NAC2 NAC2 NAC2 NAC2 NAC2— NAC • Engineer's Office �421A� AC2 SPKR 1 AMP7 SPKR1 AMP7,8 FACP2 FAPP12 FAPP13 FAPP14 FAPP15 FAPP15 NAC4 FAPP15 NAC2 SPKR CCI SPKR W4UN CCI SPKR SPKR NAC3 —rte NAC3 NAC4 Elev. Lobby NAC4 NAC4 NAC4 tanci NAC4 NAC4 —�� 435 U.. Stair #2 tan•ard K Stud'o SPKR NAC1 SPKR NAC1 SPKR NAM NAM NAM RP FAP 13 NAC1 NAC4 S udio QQ Studio QQ Studio QQ 0 tud o K Studio K 413 S udie QQ 412 Studio QQ Studio K 1_r J Inl Studio K 425 FAPP13 NAC3 Studio K Stan•arp K tair #1 ST -1 110 a lI 1 -fed, 401 0 Studio QQ 427 1 -Bed 429 NORTH Floor 4 Notification SCALE: 1 /8" =1' 1c i9 CQ 443 2' 4' 16' 32' 0) ■ 0 �M C'♦ N WO a) w � O v/ co CO 0 O �U C 0 s' ^ W �J c 0 E 0 U E Co a) U a) 0 co N C) 0 N 0 LL W CO CD_ a. CO a co Lo I- 0 wn By: EJB Checked By: JPJ Job #: 1903 Revisions: # i I Revision Notes 0 2018/12/26 Original Drawing 1 2019/04/23 Changes for Smoke Control / HVAC Coordination 2 __U._ Device relocations per Owner 3 Elev. Lobby NAC4 NAC4 NAC4 tanci NAC4 NAC4 —�� 435 U.. Stair #2 tan•ard K Stud'o SPKR NAC1 SPKR NAC1 SPKR NAM NAM NAM RP FAP 13 NAC1 NAC4 S udio QQ Studio QQ Studio QQ 0 tud o K Studio K 413 S udie QQ 412 Studio QQ Studio K 1_r J Inl Studio K 425 FAPP13 NAC3 Studio K Stan•arp K tair #1 ST -1 110 a lI 1 -fed, 401 0 Studio QQ 427 1 -Bed 429 NORTH Floor 4 Notification SCALE: 1 /8" =1' 1c i9 CQ 443 2' 4' 16' 32' 0) ■ 0 �M C'♦ N WO a) w � O v/ co CO 0 O �U C 0 s' ^ W �J c 0 E 0 U E Co a) U a) 0 co N C) 0 N 0 LL W CO CD_ a. CO a co Lo I- 0 wn By: EJB Checked By: JPJ Job #: 1903 Revisions: # Date Revision Notes 0 2018/12/26 Original Drawing 1 2019/04/23 Changes for Smoke Control / HVAC Coordination 2 2019/05/08 Device relocations per Owner 3 4 5 6 7 8 9 10 11 12 Engineers Stamp: Drawing/Document prepared by: Ephriam J. Bistline NICET Certification No. 136272 Fire Alarm Systems - Level IV Certification Expires: 05/01/2019 This Drawing is the exclusive Property Of Reliance Electric, and was prepared for the exclusive use of Reliance Electric and its affiliates, for the services performed by Reliance Electric. No use, reproduction or duplication of this drawing or associated documents, in part or whole may be made without the written consent of Reliance Electric. This Drawing does not constitute an enaineers or architects annrnvai hitt is r_nnciriamti o chnn riroiaiinn for installation purposes of Reliance Electric. Sheet Number: FA -14 Floor 4 Fire Alarm � Notification Plan 1 -Bed & Stua Standa Standee Itandard K I°NAC4 1W SPKR C11lWllfatCC1 SSB Corridor SPKR NACI SPKR NACI SPKR NACI SPKR NACI SPKR NACI SPKR NACI SPKR NACI SPKR NACI SPAR NACI SPKR NACI SPKR NACI SPAR NACI SPKR NACI SPKR NACI SPAR NACI SPAR NACI SPKR NACI SPKR NACI SPKR NACI SPKR NACI SPKR NACI SPKR NACI SPKR NACI SPKR RACI SPAR NACI SPKR NACI SPKR NACI FAPP18 NAC2 FAPP17 ►L�A T, .� F Rei IG r 1 I FAPP16 FAPP17 FAPP18 FAPP19 FAPP19 NAC4 Linen AMP9 SPKR1 NAC4 i 1(-)NAC4 NAC4 NAC4 NAC4 NAC4 Studio NAC4 HAD FAPP19 �LN�1C2 Standard K St Stair #2 ndard K 539 Elev. Lobby Studio QQ 525 Studio QQ 527 1 -Bed 529 SPAR C2 SPKR AC2 SPAR AC2 NACI- NACC NAC ]L g1oI 1W o FAR FAPP10 NACI NAC4 C St dio QQ L 1II tudio QQ Studio QQ 517 Studio QQ Studio K 110 1W Studio QQ Studio K ADA TS Studio K 511 Studio K ®---{ 509 Studio K Standard K = 505 Stair #1 ST -1 1 Studio K 531 NORTH Floor 5 Notification SCALE: 1/8" = 1' 2' 4' 8' 16' 32' CO 0 O d) co CV 1-6 O a) Co " 0 Ets- V J 0 U-- Co 0 z,-; A `W L ) > c I E 0 0 E CQ a) W 0 1E5_ LO CCS 0 Co N. 0 CV awn By: EJB Checked By: JPJ Job #: 1903 Revisions: # Date Revision Notes 0 2018/12/26 Original Drawing 1 2019/04/23 Changes for Smoke Control / HVAC Coordination 2 2019/05/08 Device relocations per Owner 3 4 5 6 7 8 9 10 11 12 Engineers Stamp: Drawing/Document prepared by: Ephriam J. Bistline NICET Certification No. 136272 Fire Alarm Systems - Level IV Certification Expires: 05/01/2019 This Drawing is the exclusive Property Of Reliance Electric, and was prepared for the exclusive use of Reliance Electric and its affiliates, for the services performed by Reliance Electric. No use, reproduction or duplication of this drawing or associated documents, in part or whole may be made without the written consent of Reliance Electric. This Drawing does not constitute an i enaineers or architects annrnval hit is t nnciriarari a chnn rirn,*,inr, for installation purposes of Reliance Electric. Sheet Number: FA -15 Floor 5 Fire Alarm Notification Plan i Revisions: # Date Revision Notes 0 2018/12/26 Original Drawing 1 2019/04/23 Changes for Smoke Control / HVAC Coordination 2 2019/05/08 Device relocations per Owner 3 SOUTH WING EAST WING 5 6 DESCRIPTION OF OPERATION 7 w SYSTEM NORMAL 0 8 9 10 THIS BUILDING IS EQUIPPED WITH STAIRWELL ' 11 12 ® ELEVATOR LOBBY SMOKE ® SMOKE DETECTOR Engineers Stamp: Drawing/Document prepared by: Ephriam J. Bistline NICET Certification No. 136272 Fire Alarm Systems - Level IV PRESSURIZATION AND CORRIDOR EXHAUST. % Z/ This Drawing is the exclusive Property Of Reliance Electric, and was prepared for the exclusive use of Reliance Electric and its affiliates, for the services performed by Reliance Electric. No use, reproduction or duplication of this drawing or associated documents, in part or whole may be made without the written consent of Reliance Electric. This Drawing does not constitute an engineers or architects aooroval but is rnncirlarc. n ehnn rirv,erinn � p a East Wing L ® HEAT DETECTOR DUCT DETECTOR A FIRE EVENT ANYWHERE IN THE BUILDING WILL: - ACTIVATE FULL BUILDING ALARM - ACTIVATE STAIRWELL PRESSURIZATION SYSTEMS - CLOSE ALL FIRE DOORS CLOSE HVAC DAMPERS NOT ASSOCIATED WITH SMOKE CONTROL ACTIVATE CORRIDOR EXHAUST ON ALL FLOORS South Wing Elevator Stair #2 Elevator Stair#2 R 0 WATERFLOW ® MANUAL STATION ® POWER DISCONNECT GENERATOR RUNNING - 0 /Stair Stair #1 #1 —' NORTH NORTH SOUTH CORRIDOR AUTO ON1� © ON OFF WING EXHAUST OFF 0 FAULT STAIR PRESSURIZATION AUTO ON 410 © ON OFF #1 1� OFF ® FAULT ELEVATOR VENT AUTO OPEN 11 0 OPEN CLOSED HOISTWAY DAMPER ;i� CLOSE ® FAULT STAIR #2 PRESSURIZATION AUTO ON OFF 41041- 0 ® ON OFF FAULT EAST WING CORRIDOR EXHAUST AUTO ON OFF t104; 0 ON OFF FAULT Outside Air Supply to Corridors i SPF -1 SPF -2 SEF -1 © OPEN ® OPEN SEF -3 © OPEN OPEN © SEF -2 ® CLOSED ® CLOSED ® CLOSED I FLOOR CONTROL CLOSED ® FAULT \\\\ FAULT FAULT FAULT DUCT DETECTOR / DUCT DETECTOR \ \ 1\A Q OPEN F\A\ OPEN © © OPEN , 1 © OPEN r WATERFLOW ® � EXHAUST 1—\\\\ OPEN © SMOKE DET ® AUTO — ® CLOSED FLOOR 5 FLOOR 5 ` CORRIDOR FAULT CLOSED ®i FAULT ® CLOSED FAULT —� ® CLOSED FAULT PULL STATION ' R LV4"5 O OFF CLOSED 0%--.;" CORRIDOR FAULT ---- OPEN OPEN © © OPEN © OPEN WATERFLOW ® EXHAUST OPEN SMOKE DET ® • AUTO CO CLOSED FLOOR 4 CLOSED i ® CLOSED —� ® CLOSED FLOOR 4 i— FAULT CORRIDOR ® FAULT FAULT \ FAULT LVL 4 PULL STATION ® OFF CLOSED ® CORRIDOR FAULT OPEN OPEN © © OPEN © OPEN WATERFLOW ® \ EXHAUST OPEN © SMOKE DET ® • AUTO —� ® CLOSED FLOOR 3 CLOSED ®� ® CLOSED — > � ® FLOOR 3 FAULT CORRIDOR FAULT FAULT CLOSED C FAULT LVL 3 PULL STATION ® OFF CLOSED ® CORRIDOR FAULT — © OPEN Elevator OPEN © © OPEN © OPEN WATERFLOW ® EXHAUST --`` OPEN FLOOR Alternate Recall R SMOKE DET ® C • AUTO —� ® CLOSED 2 FAULT CORRIDOR Floor CLOSED ®i FAULT ® CLOSED FAULT —� ® CLOSED FAULT PULL STATION ® LVL 2 OFF FLOOR 2 CLOSED ®*— CORRIDOR FAULT © OPEN Motorized door for corridor smoke exhaust air intake Elevator © OPEN` WATERFLOW ® EXHAUST ��` Makeup air intake for corridor OPEN © Primary Recall SMOKE DET ® = AUTO smoke exhaust system OFLOOR 1 R CLOSED FAULT CORRIDOR t Floor .—� R O CLOSED \ FAULT LVL- 1 PULL STATION ® `►of OFF _ FLOOR 1 CLOSED ®i— CORRIDOR FAULT / STAIR #1 \ ELEVATOR STAIR #2 © OPEN ® CLOSED FAULT OPEN © CLOSED ® FAULT CT) LAMP TEST OVERALL MANUAL OVERRIDE ON OFF SOUTH WING EAST WING 1 r1 RI 44 co ILD2 W 92 ca 0 co co O 0 ti Lf) O C3) ce) C\I Co O -o Co O 0 U a) d- 0 E O U E co a) a) U Co c) O 1.0 CO N N- N / Drawn Bv: EJB Checked By: JPJ Job #: 1903 Revisions: # Date Revision Notes 0 2018/12/26 Original Drawing 1 2019/04/23 Changes for Smoke Control / HVAC Coordination 2 2019/05/08 Device relocations per Owner 3 4 5 6 7 8 9 10 11 12 Engineers Stamp: Drawing/Document prepared by: Ephriam J. Bistline NICET Certification No. 136272 Fire Alarm Systems - Level IV Certification Expires: 05/01/2019 This Drawing is the exclusive Property Of Reliance Electric, and was prepared for the exclusive use of Reliance Electric and its affiliates, for the services performed by Reliance Electric. No use, reproduction or duplication of this drawing or associated documents, in part or whole may be made without the written consent of Reliance Electric. This Drawing does not constitute an engineers or architects aooroval but is rnncirlarc. n ehnn rirv,erinn for installation purposes of Reliance Electric. Sheet Number: FA -1 6 Smoke Control Panel Detail FIRE ALARM AND SMOKE CONTROL SHOP DRAWINGS FOR A NEW FACILITY: BY WEST N SITE ADDRESS: 515 INDUSTRY DRIVE TUKWILA, WA 98188 PROJECT LOCATION MunitIpat a C itay Arlet,Ca- Long3aae; way`:`. ^hairy acf.cn Bakes Btvd r•Tf, spt�f au:hcenter_ Mast Treck Dr 515 Industry Dr. Tukwila,. WA 98188 SW 2 Wig Blvd •Wit, "col. inantre Cufrt ri BrF34: ra ncalq S .. SCticU.' ,recex:c C ran kttttew'�.. : wf .r1we:'or Lev' BUILDING INFORMATION PAGE NO. FLOORS: GENERAL CONTRACTOR 5 SQ.FT.: AUTHORITY HAVING JURISDICTION 116,665 OCCUPANCY: ` R1 UNITS: SMOKE CONTROL RISER AND DETAILS 177 BUILDING TYPE: FA -6 V-A SPRINKLERED: FLOOR 3 INITIATING AND SMOKE CONTROL PLAN YES FLOOR 4 INITIATING AND SMOKE CONTROL PLAN FA -9 FLOOR 5 INITIATING AND SMOKE CONTROL PLAN FA -10 ROOF INITIATING AND SMOKE CONTROL PLAN FA -11 ACCsT 0 Without Comments p -- As Noted in Rel • Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau sr conformance with current City standards. AcceP- 5ubject to errors and omissions which cr 1,Cc authorize violations of adopted ' ardards and ordinFl.Yl_. ,. The responsibility for the adequacy of desi..: yr + totally with the designer. Additions, deletions =;t. revisions to these drawings after this date will void this acceptance and will require a resubmittal -of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bu eau Date: 7 -10 - 1 1 By: sly Fire Permit Number To schedule inspections call 206-575-4407 NOTICE A complete 4, signed, Tukwib Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the•testirp • DRAWINGS PREPARED BY: ;Reliance Electric 4795 OAKLAND STREET DENVER, CO 80239 (720) 749-2850 WWW.RELIANCETEAM.COM FIRE ALARM SCOPE OF WORK FIRE ALARM AND SMOKE CONTROL SYSTEMS FOR A 5 FLOOR, 116,665 SQUARE FOOT ELEMENT HOTEL BY WESTIN. THE SYSTEM SHALL INCLUDE AUTOMATIC DETECTION PER MARRIOTT LIFE SAFETY STANDARDS AND THE INTERNATIONAL FIRE CODE, SPRINKLER MONITORING, VOICE EVACUATION, FIRE-FIGHTER TELEPHONES AND THE CONTROL AND MONITORING FOR THE PRESSURIZED STAIRWELLS AND SMOKE EXHAUST SYSTEMS AND SHALL COMPLY WITH ALL APPLICABLE CODES AND STANDARDS INCLUDING CITY OF TUKWILA CITY ORDINANCES AND THE CODE AMENDMENTS FROM CITY OF TUKWILA AND WASHINGTON STATE. PROJECT CONTACTS PAGE NO. BUILDING OWNER GENERAL CONTRACTOR ELECTRICAL ENGINEER SMOKE CONTROL ENGINEER AUTHORITY HAVING JURISDICTION TUKWILA HOTEL GROUP, LLC 1735 S 19TH AVENUE, SUITE B BOZEMAN, MT 59718 KEY CONSTRUCTION (316) 263-9515 KNKASSELMAN@KEYCONSTRUCTION.COM ROBINSON ENGINEERING INC. (206) 364-3343 UNITED BUILDING & ENGINEERING SVCS (425) 591-4633 BOB.LONG UNITEDBES.COM CITY OF TUKWILA FIRE MARSHAL'S OFFICE (206) 575-4407 FIREMARSHAL@TUKWILAWA.GOV Drawing/Document prepared by: Ephriam J. Bistline NICET Certification No. 136272 Fire Alarm Systems - Level IV Certification Expires: 05/01/2019 SHEET INDEX PAGE NO. PAGE NAME COVER COVER SHEET FA -1 FIRE ALARM GENERAL INFORMATION FA -2 FIRE ALARM SLC & BAKCBONE RISER FA -3 FIRE ALARM NAC RISER FA -4 SMOKE CONTROL RISER AND DETAILS FA -5 5 FL O R1 O INITIATING AND SMOKE CONTROL PLAN FA -6 FLOOR 2 INITIATING AND SMOKE CONTROL PLAN FA -7 FLOOR 3 INITIATING AND SMOKE CONTROL PLAN FA -8 FLOOR 4 INITIATING AND SMOKE CONTROL PLAN FA -9 FLOOR 5 INITIATING AND SMOKE CONTROL PLAN FA -10 ROOF INITIATING AND SMOKE CONTROL PLAN FA -11 FLOOR 1 NOTIFICATION PLAN FA -12 FLOOR 2 NOTIFICATION PLAN FA -13 FLOOR 3 NOTIFICATION PLAN FA -14 FLOOR 4 NOTIFICATION PLAN FA -15 FLOOR 5 NOTIFICATION PLAN FA -16 FIRE SMOKE CONTROL PANEL RELIANCE ELECTRIC CONTACTS DRAWINGS PREPARED BY DRAWINGS CHECKED BY RELIANCE PROJECT MANAGER EJ BISTLINE (702) 343-3674 EJ.BISTLINE@RELIANCETEAM.COM RULON MUSSER (720) 250-7675 RULON.MUSSER@RELIANCETEAM.COM RULON MUSSER (720) 250-7675 RULON.MUSSER@RELIANCETEAM.COM PAID SYMBOL LEGEND QTY SYMBOL DESCRIPTION MANUFACTURER PART NUMBER MOUNTING CONTROL / POWER PANELS 2 18/2 FIRE ALARM CONTROL PANEL KIDDE VS4-GD BACKBOX [ AC 1 SLC CIRCUITS 19 MC CABLE FIRE ALARM REMOTE POWER PANEL KIDDE MIRBPSI OA BACKBOX FAPPx SLC4 SLC4 5 FIRE ALARM REMOTE AMPLIFIER KIDDE APS10A / SIGA-AA50 BACKBOX AMPx NACI NACI 2 (FAA) FIRE ALARM REMOTE ANNUNCIATOR PANEL KIDDE K-RLCD-C 4S BOX INITIATING DEVICES 135 O SMOKE DETECTOR WITH STANDARD BASE KIDDE KI -PD / KI -SB 3" ROUND BOX 233 QB SMOKE DETECTOR WITH LOW FREQUENCY SOUNDER BASE KIDDE KI -PD / KI-ABLT 4S BOX 13 OHEAT DETECTOR WITH STANDARD BASE KIDDE KI-HRD / KI -SB 3" ROUND BOX 4 s DUCT SMOKE DETECTOR KIDDE GSA -SD N/A 2 120V CIRCUITS** MANUAL PULL STATION KIDDE GSA -M278 1 GANG BOX F *Speaker circuits between control panels and amplifiers shall be CI Rated and enclosed in metal raceways. **120V Circuits shown for reference only. These will be supplied, installed and terminated by the electrical contractor. 3 CO CARBON MONOXIDE DETECTOR SYSTEM SENSOR CO -1224T / CO-1224TR 1 GANG BOX MONITORING / CONTROL MODULES 4 00 FIRE ALARM CONTROL RELAY KIDDE GSA -CR 1 GANG BOX 35 aH FIRE ALARM HIGH VOLTAGE CONTROL RELAY KIDDE GSA -CRH 4S BOX 12 SINGLE INPUT MODULE KIDDE GSA -CTI 1 GANG BOX 42 02 DUAL INPUT MODULE KIDDE GSA-CT2 1 GANG BOX 16 la REMOTE MONITOR MODULE KIDDE GSA-RM1 2 GANG BOX 194 ® SIGNAL CONTROL MODULE KIDDE GSA -CCI 2 GANG BOX NOTIFICATION DEVICES 306 15 1W WALL MOUNT SPEAKER STROBE (CANDELA AND WATTAGE INDICATED) KIDDE G4HFWF-S7VMC 4S BOX 17 15 1W O c CEILING MOUNT SPEAKER STROBE (CANDELA AND WATTAGE INDICATED) KIDDE GCHFWF-S7VMC 4S BOX 2 1 15 WEATHER PROOF SPEAKER STROBE (CANDELA AND WATTAGE INDICATED) KIDDE INT-4ASW BACKBOX WP 19..2.WALL • /15 MOUNT STROBE (CANDELA INDICATED) KIDDE EG1 F -VM 1 GANG BOX 1 WP 110 WEATHERPROOF HORN STROBE AND BACKBOX (CANDELA INDICATED) KIDDE INT-8ATW /INT-WBW BACKBOX wJ DEVICES FOR AUXILIARY FUNCTIONS 15 0 FIREFIGHTER PHONE JACK KIDDE 6833-4 1 GANG BOX I ®I J 29 MAGNETIC DOOR HOLDER INTERLOGIX DHF -24120C 1 GANG BOX DH 16 (FSD) FIRE / SMOKE DAMPER (SUPPLIED AND INSTALLED BY OTHERS) N/A N/A N/A WIRE LEGEND LINETYPE DESCRIPTION WIRE SIZE / NO OF CONDUCTORS JACKET JACKET COLOR CONDUIT I SMOKE CONTROL CIRCUITS 18/2 2 HR CI RATED RED EMT SC se 3 SLC CIRCUITS 18/2 MC CABLE RED NONE SLCI SW SIC3 sirs SLC4 SLC4 SLC5 SLC5 - NOTIFICATION CIRCUITS 14/2 FPLR RED NONE NACI NACI NNAc2 --- NAC3 C3 NAC3 NAC4 NAC4 • SPEAKER CIRCUITS 16/2 SHIELDED FPLR* ORANGE NONE" SPKR SPRR 0 DATA BUS CIRCUITS 18/4 2 HR CI RATED RED EMT Deus Deus NICET Certification No. 136272 SENS Circuits 18/4 2 HR CI RATED RED EMT SESb SE ,S 24V AUXILIARY POWER CIRCUITS 18/2 ZIP WHITE NONE AUX PIAN Aux PWR 120V CIRCUITS** N/A N/A N/A N/A 12111 120V *Speaker circuits between control panels and amplifiers shall be CI Rated and enclosed in metal raceways. **120V Circuits shown for reference only. These will be supplied, installed and terminated by the electrical contractor. INPUT / OUTPUT MATRIX Control Unit Annunciation Notification Control Smoke Control FAPP ROUGH -IN DETAIL A 5'-6" AFF / FINISHED FLOOR MOUNTING HEIGHTS CEILING LINE FIRE 42" Min 48" Max V 80" Min 6" 96" Max V 6" Min 90" Min mmo 3= 0 60" A 66" / / / FINISHED FLOOR FAPP / AMP ROUGH -IN DETAIL Power stub on left side of stud 5'-0" AFF Fire Alarm wire stub on right side of stud *Protect stubbed wires and cables from physical damage using conduit or nail and tape. / FINISHED FLOOR FIRE ALARM GENERAL NOTES 1. Fire alarm contractor will coordinate with fire sprinkler contractor to ensure that all waterflow devices and all required valves are monitored. This includes the PIV if applicable. 2. Smoke / heat detectors located next to fire alarm control units, remote power supplies and amplifier panels shall be located directly above the panel as much as possible. 3. Ensure all smoke detectors are located not less than 36" from HVAC air vents and diffusers. 4. No smoke detectors shall be installed until after construction clean-up of all trades is complete. 5. The electrical circuit breaker for all fire alarm control panels, power supplies and amplifier panels shall be red in color, clearly marked "Fire Alarm" and a breaker lock shall be installed. 6. Magnetic Door Holder power shall be discontinued in the event of A/C power loss to prevent excessive battery usage. 7. Monitor modules / control relays for outside HVAC units shall either be installed inside the building in an accessible location or in weatherproof enclosures. 8. Fire Alarm contractor shall provide a printer for the fire alarm system. APPLICABLE CODES AND STANDARDS 1. 2015 International Building Code (IBC) with Tukwila City Amendments 2. 2015 International Fire Code (IFC) with Tukwila City Amendments 3. 2016 NFPA 72 Fire Alarm and Signaling Code 4. 2017 National Electric Code (NEC) 5. Tukwila City Ordinance No. 2437 6. Tukwila City Ordinance No. 2330 7. Marriott Module 14 Life Safety Standards TERMINAL WIRING METHODS INCORRECT CORRECT DETECTOR MOUNTING DETAIL CEILING Acceptable here Top of detector acceptable within 12" of ceiling Never below here Note: Measurements shown are to the closest edge of the detector M O SIDEWALL Example of Proper Detector Mounting NFPA 72 2016 A.17.6.3.1.3.1 a) C!) Ca Co 0 Lf) 0) ti Lt) Lf') (3-) co CV O 00 0 -oCo O O 0 a) > a) a E O U E co a) a) U CO Cp LC) Co CV 0 N. CD N awn By: EJB Checked By: JpJ Job #: 1903 ABCDEFGH # Date Revision Notes 0 2018/12/26 I / • I J KLMNOPQRSTUVWXYZAA 2019/05/08 Device relocations per Owner 3 4 5 6 7 8 Open Circuit 9 • • 11 12 0 Engineers Stamp: Drawing/Document prepared by: Ephriam J. Bistline NICET Certification No. 136272 Fire Alarm Systems - Level IV Certification Expires: 05/01/2019 4.-Ecw:t- This Drawing is the exclusive Property Of Reliance Electric, and was prepared for the exclusive use of Reliance Electric and its affiliates, for the services performed by Reliance Electric. No use, reproduction or duplication of this drawing or associated documents, in part or whole may be made without the written consent of Reliance Electric. This Drawing does not constitute an enaineers or architects arum -oval hut is cnnsidarari a chnn rirawinn 1 Trouble Circuit Short • • • 2 System Ground Fault 0 0 0 3 AC Power Fail • • • 4 Fire Alarm System Low Battery 0 0 0 5 Device Fail • • • 6 Device Missing o 0 • 7 Device Out of Tolerance • • 0 8 9 Common Area Smoke Detector • • 0 • • • • 0 0 • 0 • 10 E CO < Heat Detector 0 • 0 0 • 0 • 0 0 0 • • 11 Manual Pull Station • 0 0 0 • • 0 • 0 0 • • 12 1st Floor Elevator Lobby Smoke Detector 0 • 0 0 • • • • • • 0 0 • 13 2nd - 5th Floors Elevator Lobby Smoke Detector 0 • 0 0 0 • • • 0 0 0 0 0 14 Elevator Hoistway Smoke Detector 0 0 • 0 0 • 0 0 0 0 0 0 0 15 Elevator Hoistway Heat Detector • • 0 o • • • 0 • • • 0 • 16 Elevator Equipment Room Smoke Detector 0 o 0 • • • 0 • • 0 • • • 17 Elevator Equipment Room Heat Detector 0 • • 0 0 • 0 0 • • • 0 • 18 Fire Sprinkler Waterflow • 0 • • • o 0 • • • 0 • 19 20 Fire Sprinkler Valve Tamper • • o 21 Supervisory Guest Suite Smoke Detector 0 0 • • 22 Duct Smoke Detector • • 0 0 23 Carbon Monoxide Detector 0 o • 24 FAPP ROUGH -IN DETAIL A 5'-6" AFF / FINISHED FLOOR MOUNTING HEIGHTS CEILING LINE FIRE 42" Min 48" Max V 80" Min 6" 96" Max V 6" Min 90" Min mmo 3= 0 60" A 66" / / / FINISHED FLOOR FAPP / AMP ROUGH -IN DETAIL Power stub on left side of stud 5'-0" AFF Fire Alarm wire stub on right side of stud *Protect stubbed wires and cables from physical damage using conduit or nail and tape. / FINISHED FLOOR FIRE ALARM GENERAL NOTES 1. Fire alarm contractor will coordinate with fire sprinkler contractor to ensure that all waterflow devices and all required valves are monitored. This includes the PIV if applicable. 2. Smoke / heat detectors located next to fire alarm control units, remote power supplies and amplifier panels shall be located directly above the panel as much as possible. 3. Ensure all smoke detectors are located not less than 36" from HVAC air vents and diffusers. 4. No smoke detectors shall be installed until after construction clean-up of all trades is complete. 5. The electrical circuit breaker for all fire alarm control panels, power supplies and amplifier panels shall be red in color, clearly marked "Fire Alarm" and a breaker lock shall be installed. 6. Magnetic Door Holder power shall be discontinued in the event of A/C power loss to prevent excessive battery usage. 7. Monitor modules / control relays for outside HVAC units shall either be installed inside the building in an accessible location or in weatherproof enclosures. 8. Fire Alarm contractor shall provide a printer for the fire alarm system. APPLICABLE CODES AND STANDARDS 1. 2015 International Building Code (IBC) with Tukwila City Amendments 2. 2015 International Fire Code (IFC) with Tukwila City Amendments 3. 2016 NFPA 72 Fire Alarm and Signaling Code 4. 2017 National Electric Code (NEC) 5. Tukwila City Ordinance No. 2437 6. Tukwila City Ordinance No. 2330 7. Marriott Module 14 Life Safety Standards TERMINAL WIRING METHODS INCORRECT CORRECT DETECTOR MOUNTING DETAIL CEILING Acceptable here Top of detector acceptable within 12" of ceiling Never below here Note: Measurements shown are to the closest edge of the detector M O SIDEWALL Example of Proper Detector Mounting NFPA 72 2016 A.17.6.3.1.3.1 a) C!) Ca Co 0 Lf) 0) ti Lt) Lf') (3-) co CV O 00 0 -oCo O O 0 a) > a) a E O U E co a) a) U CO Cp LC) Co CV 0 N. CD N awn By: EJB Checked By: JpJ Job #: 1903 Revisions: # Date Revision Notes 0 2018/12/26 Original Drawing 1 2019/04/23 Changes for Smoke Control / HVAC Coordination 2 2019/05/08 Device relocations per Owner 3 4 5 6 7 8 9 10 11 12 Engineers Stamp: Drawing/Document prepared by: Ephriam J. Bistline NICET Certification No. 136272 Fire Alarm Systems - Level IV Certification Expires: 05/01/2019 4.-Ecw:t- This Drawing is the exclusive Property Of Reliance Electric, and was prepared for the exclusive use of Reliance Electric and its affiliates, for the services performed by Reliance Electric. No use, reproduction or duplication of this drawing or associated documents, in part or whole may be made without the written consent of Reliance Electric. This Drawing does not constitute an enaineers or architects arum -oval hut is cnnsidarari a chnn rirawinn for installation purposes of Reliance Electric. Sheet Number: FA -1 Fire Alarm General Information Backbone Riser Diagram Dedicated 120V from building electrical system. Panel and circuit to be field assigned. Power Supply MIRBPS6A SLA Batteries FAPP16 120V Dedicated 120V from building electrical system. Panel and circuit to be field assigned. Power Supply MIRBPS6A SLA Batteries FAPP17 Power Supply MIRBPS6A SLA Batteries FAPP18 1202 Dedicated 120V from building electrical system. Panel and circuit to be field assigned. Power Supply MIRBPS6A SLA Batteries FAPP19 Floor 5 Dedicated 120V from building electrical system. Panel and circuit to be field assigned. —1202 —I—I r -- Power Supply SLA Batteries Dedicated 120V from building electrical system. Panel and circuit to be field assigned. FACP2 SLA Batteries Power Supply MIRBPS6A 1202 Dedicated 120V from building electrical system. Panel and circuit to be field assigned. SLA B-tteries FAPP15 Power Supply MIRBPS6A SLA Batteries FAPP14 Power Supply MIRBPS6A SLA Batteries FAPP13 120V Dedicated 120V from building electrical system. Panel and circuit to be field assigned. Power Supply MIRBPS6A SLA B-tteries FAPP12 Floor 4 Dedicated 120V from building electrical system. Panel and circuit to be field assigned. —1202 —I -I Power Supply SLA Batteries Cel CO CO CO Power Supply MIRBPS6A SLA .tteries FAPP8 1202 Dedicated 120V from building electrical system. Panel and circuit to be field assigned. Power Supply MIRBPS6A SLA Batteries FAPP9 Power Supply MIRBPS6A SLA Batteries FAPP10 1202 Dedicated 120V from building electrical system. Panel and circuit to be field assigned. I I Power Supply MIRBPS6A SLA Batteries FAPP11 SJIS Floor 3 Dedicated 120V from building electrical system. Panel and circuit to be field assigned. CO Power Supply MIRBPS6A 120V Dedicated 120V from building electrical system. Panel and circuit to be field assigned. SLA Batteries FAPP7 Power Supply MIRBPS6A SLA Batteries FAPP6 Power Supply MIRBPS6A SLA Batteries FAPP5 120V Dedicated 120V from building electrical system. Panel and circuit to be field assigned. Power Supply MIRBPS6A SLA Batteries FAPP4 Floor 2 Dedicated 120V from building electrical system. Panel and circuit to be field assigned. 1202 AMP2 f- t AMP1 I Power Supply SLA Batteries FAA FAA SPKR SPKR Dedicated 120V from building electrical system. Panel and circuit to be field assigned. 61�.7111 FACP1 SLA Batteries SL°CS Dedicated 120V from building electrical system. Panel and circuit to be field assigned. Connection to AES radio for off-site monitoring. Power Supply MIRBPS6A SLA Batteries FAPP1 Dedicated 120V from building electrical system. Panel and circuit to be field assigned. Power Supply MIRBPS6A SLA Batteries FAPP2 120V Power Supply MIRBPS6A SLA B.tteries FAPP3 Floor 1 Riser Notes 1. All smoke control circuit cabling shall be 2 -hour fire rated cable enclosed in metallic raceway. Raceway provided and installed by Electrical Contractor. 2. All SLC circuit cabling shall be MC cable listed for use as fire alarm cabling. 3. All fire alarm control/monitor modules for units/dampers on roof shall be suitably protected from the weather. This shall be accomplished by either providing a weatherproof enclosure or installing the devices inside the building. SLC and Smoke Control Riser Diagram ®©® ©SB a eSB ®e CoeSB G e ©SB a Go ®e ©SB ® 0 a eSB eSB 0 ® eSB a eSB l © SB a eSB Co ©® eSB 411,eSB e © e © e X2SB X2 X2 X2 X2 X2 X2 X2SB X2 X2 X2 FAPP X4 AMP eSB © ©SB ® ©sB eSB ® ©sB ® ©SB ©SB ® ©SB ® ©sB ®0 4110 0 eSB eSB © Co2 a eSB ®e ©SB G © eSB ® ©SB a eSB ®0 a eSB a eSB illo e X2 X3 X2 X2 X2 X2 X2 eSB © eSB ®0 a eSB a 0 ® 0 ®©SB It a eSB ® e ito 0 ®e eSB ® e eSB Go eSB a 0 ® eSB Z eSB Ito ©SB ® ©S eSB ® ©SB ® ©® 0 X2 X2 X2SB X2 X2 X2 X2 X3 X2 X2 X2 X2 X2 X2SB 0SB ®©SB ® ©SB ®Go ® ©SB ® eSB ®0 SB ®SB ® AB ®e ®® eSB ®0 SB a C2 eSB ®e ® eSB a Go ® eSB a ©SB ® ©SB e ® eSB a eSBollo X3 X2 X2 X2 X2 ©SB Co eSB ® 0 a eSB ®0 X2 SB Go esg aSB e ® OSB ® e eSB ® ® eSB ® e eSB ® e eSB Go eSB ® eSB eSB eS B e a X3 X2 X2 X2 X3 X2 ® eSB ® 0 ® eSB ® 0SB ® ©SB G ® eSB ® ©SB ® ©SB a ®2 a eSB ® eSB a eSB o SB ® e eSB ®e ® eSB eSB 4111, X2 X2 X2 AMP FAPP X4 X2 X2 AMP SI C5 SLC4 FAPP X4 B ® 0SB ®0 SB X2 X2 X2 e©SB 41 SB t: ."' X2 X2 SLC5 SLC4 SLC4 RCS 5153 51.53 FACP2 SLA Batteries ,r SLC3 Smoke Control Circuit FSD FSD 411:0 Co FSD) -(FSD) Co Co FSD SC 15 Elevator Relief FSD I Damper FSD —(FSD) —( FSD) —{ FSD) —( FSD) — � FSD) FSD) FSD (FSD) Clto Co Co 0 FSD —(FSD) Co Co FSD Roof Floor 5 Floor 4 Floor 3 ® ©SB ® ©SB eSB eSB ® S6 eSB a s6 ©SB a CD ©S6 to a eto fit © ® eSB a to ©sB ©SB a eSB 411, eSB ©SB a ©SB ©SB ©sB ©SB ® esg X2 X2 X3 X2 X2 X2 X4 X3 X2 X7 ©SB ©SB • AB ek eSB ® OSB 421°©SB AB ® eSB ® 0 ©s9 �2 0 eSB ® Os 0 OSB t� 0 OSB alka B ® eSB a ©5B t� B it e ® eSB B X2 X4 X2 X2 5LC2 SLC2 w eto 0 ilto es6 ®ollto eSB Ito es6 ® eSB ® eSB ® eSB 411, ©SB ® esB 41 eSB t3� O. 0 © © e ©0 © e X2 X2 X2 X5 00©SBt3�aCo0 a 000S64�00 SB SB FAPP X2 tlito C►n ► 0 3 AMP FAPP X24 X4 X2 X3 Co Co e e ©e © e X4 X5 SIC1 SIC/ y N FSD — (FSD) —(FSD) FSD Floor 2 i ®P111 FACP1 ISOLA Btteries —( FSD) Makeup Air I Damper —(FSD) SC SC SC Sc SC SC SC SC SC SC SC Co Co FSD - --) Motorized Door Floor 1 t) t 44 co Cb Q N ^L 0-) V a ED_ C J Co CCS 0 LC)) LC) LC) 0 M N Co Co 0 Co 0 0 U W 0 E 0 U E a) CU U co awn By: EJB Checked By: JPJ Job #: 1903 Revisions: # Date Revision Notes 0 2018/12/26 Original Drawing 1 2019/04/23 Changes for Smoke Control / HVAC Coordination 2 2019/05/08 Device relocations per Owner 3 4 5 6 7 8 9 10 11 12 Engineers Stamp: Drawing/Document prepared by: Ephriam J. Bistline NICET Certification No. 136272 Fire Alarm Systems - Level IV Certification Expires: 05/01/2019 This Drawing is the exclusive Property Of Reliance Electric, and was prepared for the exclusive use of Reliance Electric and its affiliates, for the services performed by Reliance Electric. No use, reproduction or duplication of this drawing or associated documents, in part or whole may be made without the written consent of Reliance Electric. This Drawing does not constitute an engineers or architects aooroval but is considered a shoo drawinn for installation purposes of Reliance Electric. Sheet Number: FA -2 Fire Alarm SLC & Smoke Control Risers • Floors 1-3 Notification Riser Diagram Floor 3 NAC3 NACI NACI 1W _110 — 1W 1W X2 X2 X2 ,15 1W • Power Supply MIRBPS6A SLA Batteries FAPP11 Power Supply NACI 1W�110 X3 X2 X2 NAC X2 AC2 NACI NACI 1W 110 _ 1W X2 ® OSB X11 1W110 AC2 0 1W 110 NACI 1W 110 0 fit Power Supply MIRBPS6A SLA Batteries FAPP8 Floor 2 NAC Power Supply NACI NACI 1W 110 _ 1W 110 X3 NACI NACI 1W',bio OS B X14 NAC3 AC2 Power Supply MIRBPS6A SLA Batteries FAPP6 ti Power Supply NACI Power Supply X2 Floor 1 NAC Power Supply X2 Power Supply 2W NACI Power Supply X2 X2 X2 1W 30 1W 15 1W 30 Floors 4-5 Notification Riser Diagram Floor 5 NAC X2 'a SB X1X11 MAC MAC >w 110 1wir,110 ►�;LI NACI 1WV110 ,O\ NACI 1W 110 0 C2 Power Supply MIRBPS6A SLA Batteries FAPP19 Power Supply NAC3 NAC3 ,15 1W ,2 0 110 43. Power Supply NAC3 NAC3 1W 110 _ 1W NAC3 NAC3 ` /15 1W X3 X3 NACI X3 X2 NACI 1W NAC3 1W NAC2 1W SB X16 X2 X2 Power Supply MIRBPS6A SLA Batteries FAPP16 Floor 4 X2 NACI X2 NACI NACI 1W 110 1W X3 NAC3 NAC ® OB X16 NAC3 1W 110 C2 1W 110 0 Power Supply MIRBPS6A X2 X2 X2 NACI 1W 110 0 ® OSB X11 NAC3 1W'110 NACI 0 1W 110 0 X2 420 1W 151W 15 1 30 1W 15 c X3 NAC3 1Win110 1310 X3 NAC3 0 X2 ®SB X16 1W 110 0 X2 X2 NACI 1W110 4110 NACI 1W 110 0 Power Supply MIRBPS6A SLA Batteries FAPP13 Power Supply MIRBPS6A SLA Batteries FAPP12 Speaker Riser Diagram Floor 5 1W110 1w� 5 1W O X16 X4 X11 Floor 4 X11 X5 X16 X16 X4 X11 X2 Floor 3 X14 X4 X11 Floor 2 X12 X4 X11 Floor 1 X2 X2 5 1W 15 1W 30 1W 15 2W 75 1W 30 2W - . 75 iW 15 1W 30 1W 30 1W X2 co to 0 1101W-30 1W 15 1W X10 X4 X9 X4 X4c X2c X2c CI) t) U C 4 Z LC) r . Lo 1co -0 0 m6 02 4) Ca -16 0 CNI a nr. 1._ 0 65 .0 2 -0 Co co o 0) C 0 w c d- a E 0 U E co N a) U as CD LC)Co N 0 0 C\1 awn Bv: Checked By: JPJ Job #: 1903 Revisions: # Date Revision Notes 0 2018/12/26 Original Drawing 1 2019/04/23 Changes for Smoke Control / HVAC Coordination 2 2019/05/08 Device relocations per Owner 3 4 5 6 7 8 9 10 11 12 Engineers Stamp: - Drawing/Document prepared by: Ephriam J. Bistline NICET Certification No. 136272 Fire Alarm Systems - Level IV Certification Expires: 05/01/2019 This Drawing is the exclusive Property Of Reliance Electric, and was prepared for the exclusive use of Reliance Electric and its affiliates, for the services performed by Reliance Electric. No use, reproduction or duplication of this drawing or associated documents, in part or whole may be made without the written consent of Reliance Electric. This Drawing does not constitute an anninaars nr arrhitants annrnval hut is i nnsiriarari a shnn drawinn for installation purposes of Reliance Electric. Sheet Number: FA -3 Fire Alarm Notification Riser Diagrams t,. Riser Notes 1. All smoke control circuit cabling shall be 2 -hour fire rated cable enclosed in metallic raceway. Raceway provided and installed by Electrical Contractor. 2. All SLC circuit cabling shall be MC cable listed for use as fire alarm cabling. 3. All fire alarm control/monitor modules for units/dampers on roof shall be suitably protected from the weather. This shall be accomplished by either providing a weatherproof enclosure or installing the devices inside the building. 4. All HVAC equipment / sensors will be provided and installed by others. 5. Current transformers and switches required for HVAC control and monitoring for smoke control functions will be provided and installed by others. 6. Fire alarm contractor to coordinate with all other contractors involved to ensure all smoke control systems and devices will function properly with provided equipment. 7. Fire alarm duct smoke detectors will be provided and installed by fire alarm contractor. 8. Coordinate with mechanical smoke control drawings to ensure all required functions are performed. Smoke Control Riser Diagram SEF -1 FLOOR 5 FLOOR 4 FLOOR 3 FLOOR 2 FLOOR 1 HVAC Shaft 2°b Typical Fire/Smoke damper with open and close confirmation switches. Provided and i installed by others. 12011 120V (By EC) 0 H AIM 2 120V 120V (By EC) Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit SLC Circuit 18/2 MC Cable Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 120V (By EC) 120V (By EC) Corridor Makeup Air •)• 1211V n 12011 0 120V SLC Circuit 18/2 MC Cable Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 120V (By EC) 120V (By EC) 120V 0 12011 SLC Circuit 18/2 MC Cable Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 120V (By EC) 120V (By EC) C) 120V 120V SLC Circuit 18/2 MC Cable Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 120V (By EC) 120V (By EC) 121V HVAC Shaft 0 South Wing Power From Disconnect VFD}— (By EC) Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 121V H SPF -1 ( CT) Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 120V (By EC) Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 120V (By EC) AF ) Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 120V (By EC) 0 Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 120V (By EC) 0 12011 Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 120V (By EC) 2J 120V SLC Circuit 18/2 MC Cable Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 120V (By EC) Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit Motorized door for corridor smoke exhaust makeup air O Elevator Relief Damper No pressurization in elevator hoistway. Elevator Alternate Recall Floor Elevator Primary Recall Floor 120V (By EC) AHU-1 I SEF -3 R Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit HVAC Shaft 120V 120V 120V SC 12011 120V (By EC) Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 120V (By EC) 12[1V Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 120V (By EC) 1201/ Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 120V (By EC) East Wing Power From Disconnect VFD)— (By EC) Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit SPF -2 (CT) AF) 120V (By EC) Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit SC 120V Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 120V (By EC) 120V Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 120V (By EC) CORRIDOR 120V (By EC) STAIR #1 ELEVATOR Makeup air intake for corridor smoke exhaust system 120V 120V (By EC) H kl] 120V (By EC) Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit SLC Circuit 18/2 MC Cable Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 120V (By EC) 120V 0 SLC Circuit 18/2 MC Cable Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 120V (By EC) 1211V SEF -2 0 \\ SLC Circuit 18/2 MC Cable Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 120V (By EC) SLC Circuit 18/2 MC Cable Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 1211V 120V (By EC) 120V SLC Circuit 18/2 MC Cable Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit 120V (By EC) 120V 0 HVAC Shaft Smoke Control SLC Circuit 18/2 CI Rated Cable enclosed in metallic conduit STAIR #2 -r CORRIDOR "rz co 0 a Q 17)1 cu CO• LO E - L 0 U- 0 a) 0 co a) 0 _I a) Q a) Q 0 c: 0) ) _ = t6 ♦on VJ 00 LC)0) F - Co E a) N CO awn By: EJB Checked By: JPJ Job #: 1903 Revisions: # Date Revision Notes 0 2018/12/26 Original Drawing 1 2019/04/23 Changes for Smoke Control / HVAC Coordination 2 2019/05/08 Device relocations per Owner 3 4 5 6 7 8 9 10 11 12 Engineers Stamp: Drawing/Document prepared by: Ephriam J. Bistline NICET Certification No. 136272 Fire Alarm Systems - Level IV Certification Expires: 05/01/2019 4-___,g,4______>—. This Drawing is the exclusive Property Of Reliance Electric, and was prepared for the exclusive use of Reliance Electric and its affiliates, for the services performed by Reliance Electric. No use, reproduction or duplication of this drawing or associated documents, in part or whole may be made without the written consent of Reliance Electric. This Drawing does not constitute an engineers or architects aanrnval but is rnnciriPrPri a chnn rirw.winr, for installation purposes of Reliance Electric. Sheet Number: FA -4 Smoke Control Riser Diagram Ii _1 Pool Equip. (CJ t•ilqVIR 1! ! Pool / Spa AUX Rilt I 1 Washroom Pool HVAC 4i4 SLCI '13 RR -1 MX FV 1ll 101 Fitness SLCI — SLCI Boardroom SLCI SLCI AUX MR AUX PM; SLCI Control relay/monitoring of outside air intake for smoke exhaust from corridors. ,',UX AUX PH SLCI SIC Sc L_ Roe- Rci 11 Ic e AUX-PO 0 SC rl SLCI - , p L .1„,„ 116 I r C. Studio K 13a) Lip E iSIC1 .,1 ,! Ir SLCI SC SESC Studio Studio K ADA RIS 136 Standagtk-- 138 stEEPID SB Corridor Mechanical SLCI Elevevator Lobby F -PHONE SLCI FSD SLCI SLCI PBX/ Server / Tel SLCI Tele Conf. Cg2 Sales F -PHONE SLCI ;Sin Break Room er SLCI Main Fire Sprinkler Flow/Tamper and Fire Pump monitor modules. Coordinate with Fire Sprinkler contractor. Electrical SID SLCI FSCPJ L.FACtlj-fEl FCC Office SG 7 0 Admin Reception La SC SID A fire alarm printer will be provided near FACP1 in the Fire Command Center. SLCI, SID , I I I SLCI /- Luggage SID Re -Store Vestibule Breakfast 2 Motorized door to open upon activation of corridor smoke exhaust system. Door and motor supplied and installed by others. fH SID Bar Storage I r SID HVAC SC SC 1 .1111 I I I I I I1 I II IIIII C SLCI Meeting 1 -Bed 129 CE OA ID SB / I!, — 11 11,1 {! AU7AU [ 0 EL Ii 0 0 XXX PHI Sc SLCI 10 SLCI LEI J SBL' L andard K Floor 2 1 1c. AUX AUX PW! , AUX RI' 0 II -'S F. 1 Standard ADA RIS 144 1--1 Stair #2 1 11 Studio K 131 NORTH Studio K 133 Studio K 135 Standard K 137 Floor 1 SLC and Smoke Control Plan SCALE: 1/8" = 1' 2' 4' 8' 16' 32' ST -2 SLCI 04D r I GAD I 00— FSD Et Standard K 139 Studio QQ ADA 141 ....f---t2,•-•••••••••••••—•••/•••••m CO CO a) a) CO Drawn By: EJB Checked By: jpj Job #: 1903 Revisions: # Date . -...---;i........;.0.--.., 2018/12/26 Original Drawing 1 1 , • 2 SLCI / SIC 4 5 — 6 ir 7 8 Cg2 Sales F -PHONE SLCI ;Sin Break Room er SLCI Main Fire Sprinkler Flow/Tamper and Fire Pump monitor modules. Coordinate with Fire Sprinkler contractor. Electrical SID SLCI FSCPJ L.FACtlj-fEl FCC Office SG 7 0 Admin Reception La SC SID A fire alarm printer will be provided near FACP1 in the Fire Command Center. SLCI, SID , I I I SLCI /- Luggage SID Re -Store Vestibule Breakfast 2 Motorized door to open upon activation of corridor smoke exhaust system. Door and motor supplied and installed by others. fH SID Bar Storage I r SID HVAC SC SC 1 .1111 I I I I I I1 I II IIIII C SLCI Meeting 1 -Bed 129 CE OA ID SB / I!, — 11 11,1 {! AU7AU [ 0 EL Ii 0 0 XXX PHI Sc SLCI 10 SLCI LEI J SBL' L andard K Floor 2 1 1c. AUX AUX PW! , AUX RI' 0 II -'S F. 1 Standard ADA RIS 144 1--1 Stair #2 1 11 Studio K 131 NORTH Studio K 133 Studio K 135 Standard K 137 Floor 1 SLC and Smoke Control Plan SCALE: 1/8" = 1' 2' 4' 8' 16' 32' ST -2 SLCI 04D r I GAD I 00— FSD Et Standard K 139 Studio QQ ADA 141 ....f---t2,•-•••••••••••••—•••/•••••m CO CO a) a) CO Drawn By: EJB Checked By: jpj Job #: 1903 Revisions: # Date Revision Notes 2018/12/26 Original Drawing 1 2019/04/23 Changes for Smoke Control / HVAC Coordination 2 2019/05/08 Device relocations per Owner 3 4 5 6 7 8 9 10 11 12 Engineers Stamp' Drawing/Document prepared by: Ephriam J. Bistline NICET Certification No. 136272 Fire Alarm Systems - Level IV Certification Expires: 05/01/2019 This Drawing is the exclusive Property Of Reliance Electric, and was prepared for the exclusive use of Reliance Electric and its affiliates, for the services performed by Reliance Electric. No use, reproduction or duplication of this drawing or associated documents, in part or whole may be made without the written consent of Reliance Electric. This Drawing does not constitute an enaineers or architects approval but is considered a shoo drawina for installation purposes of Reliance Electric. Sheet Number: FA 5 Floor 1 SLC Smoke Control Plan Standar St dio Q \; 228 mmons SLE2 , Corridor SLC2 SLC2 —170T1 Floor 1 4 Floor 3 Floor 3 Floor 1 r-- � J, SLC2 2nd Floor Fre Sprinkler --Flow/Tamper monitor. Floor 3 Sta dard K ommons Suite Floor 1 CtE Studio QQ Studio QQ -Bed 1 -Bed 229 Studio K Studio QQ St dio QQ Studio QQ Studio QQ 216 Studio K Studio K SLC2, rrl L 0-1 o� O T f o Studio K Studio K Studio K 207 dard K Standar SLC2 Floor Floor 3 tair #1 Floor 1 n I U 231 NORTH Studio K 233 Studio K 235 Standard K 237 Floor 2 SLC and Smoke Control Plan SCALE: 1/8" = 1' 2' 4' 8' 16' 32' Stud o 1 E5, co 0 n W co W E 0 U E co a) L.r) � U OCO•� MI ED_ CV S N co L (II CD tic 0" 001r) co 0 CO v VJ O 43 h - d' C O �ti O ti awn By: EJB Checked By: JPJ Job #: 1903 Revisions: # Date Revision Notes 0 2018/12/26 Original Drawing 1 2019/04/23 Changes for Smoke Control / HVAC Coordination 2 2019/05/08 Device relocations per Owner 3 4 5 6 7 8 9 10 11 12 Engineers Stamp: Drawing/Document prepared by: Ephriam J. Bistline NICET Certification No. 136272 Fire Alarm Systems - Level IV Certification Expires: 05/01/2019 4 --_,<_____>--- This Drawing is the exclusive Property Of Reliance Electric, and was prepared for the exclusive use of Reliance Electric and its affiliates, for the services performed by Reliance Electric. No use, reproduction or duplication of this drawing or associated documents, in part or whole may be made without the written consent of Reliance Electric. This Drawing does not constitute an engineers or architects aooroval but is considered a shon drawinn for installation purposes of Reliance Electric. Sheet Number: FA Floor 2 SLC & Smoke Control Plan -Bed 324 LL IL] 1 • 0 322 IRL I, I SB 10001 SB SLC3 LI 0 0 0 I 1 I 1 OSB TI (°Ij 1 Bed 320 • SB St SLC3 Corridor 300 0 0 0 0 I elt) SB 51.C3 _J I 0 0 9)6 SB 9 jrvi 2 -Be 0 LL j- J1H 326 1: 5C3 WO' E 51C31 71 L , , I 'Ice SB LI frol!! — , LISC SC SC \N,.....Floor 4 Sir 0 0 SLC3 St A% —ea S 3 I. I r St dio QQ S [ a Th 171 • • S Stuc 0°I io K 3' 4 SB r-71 t dio QQ T2 sicp 510 SLC3 lt SBO Floor 2 -< 0 caC ill 00 SL ' LmJ r SLC1 I I I 1 — I I 7 - Sic 0 0 S io K 07 0'0 sic [-p 0 01 I SB St ndard K 306 SLC3[ j JL1 0 5E3 1 - 0 I- Ce3 SB I, I I MIN t IOTA SB [) 0'0 SB SLC3 U 5E3 .111 U 2 -Bed 41Mob `111r OSB 11F0 llb 0 Floor 2 fl gal Linen 321 0 2 sr SC OH Floor 4 0 Elev. Lobby 319 sici r.n 00 1-7 r mm alM1111. 4111b* SB 0 L F SLC3 t dio Qt WW1. 411111 SB • 1 -Bed I/ 30 Floor 2 Floor 4 0•0: ft -r SB T ccl 5E3 0 0 SB 0 • 00 M • 0 SB 0 ---------- I 7 cio K 0'0 SB j1 0'0 SB „armiipail/NRINIP • • 51E3 • 7-\ IL.!! \ \.C. 0 9 ( ) s• Studio QQ 325 Studio QQ $110:.M SB DD L_J 0 {fj I mm eve SB I. 317 Studio QQ ADA TS 315 Studio K I 313 —FIEO FA lo S C cablizSTOI, and from thF/1/2P shall be ruted no less than a rt. 40v0 SB oO Studio K 4) 00 ! ! OVSB Stand^ d K 0 Floor2. 311 Studio K 309 111 1111111171 30 Ii Studio K 308 411 H Stair #1 EBB iN Floor -2 I- 1 1-Bcd 30 sE72.:J___111, I Studio QQ 327 1 -Bed 329 0.0 SB 510 L72.71 'I Stud 4 05B 0 0 I I I SIM ucio K 0'0 SB [Li rj '1 1 5E3 LI I' 1 0'0 SB 7 LI III E kr- 111•10111•111...masuralla Studio K 331 NORTH @I. Studio K 333 0'40 SB 510 .1 dard K 338 SB U7J1 ?1 UEi 11 I SLC3 HT 0 Int a 340 Bill 1 1.7r--. _ I j M SLE3 Floor 2 ijij 71. por Floor Stand rd K SB r1111111 13. • NfTn Co 3rd Floor Fire Sprinkler Flow/Tamper monitor. DN Stair #2 ST -2 SIC3 Floor 4 IIIU 111 SB ard K 342 Ovfa ,„ SB k11 11 tandard K 44 V° SBe L717} Li Floor 2 7 IL. Standard K 339 5E3 SC Olt SLC3 SlC3 tudio MIMed 03 Floor 4 LJJ • 0v0 LIII •udio 0 MaeMer411.11111. Studio K 335 Floor 3 SLC and Smoke Control Plan SCALE: 1/8" = V 11111111v 4111110101M/ z Vj V / / 2' 4' 8' 16' 32' Co a) CO awn By: EJB Checked By: JPJ Job #: 1903 Revisions: Date Revision Notes 2018/12/26 Original Drawing 1 2019/04/23 Changes for Smoke Control / HVAC Coordination 2 2019/05/08 Device relocations per Owner 3 4 5 6 7 8 9 10 11 12 Engineers Stamp" Drawing/Document prepared by: Ephriam J. Bistline NICET Certification No. 136272 Fire Alarm Systems - Level IV Certification Expires: 05/01/2019 Z-- This Drawing Drawing is the exclusive Property Of Reliance Electric, and was prepared for the exclusive use of Reliance Electric and its affiliates, for the services performed by Reliance Electric. No use, reproduction or duplication of this drawing or associated documents, in part or whole may be made without the written consent of Reliance Electric. This Drawing does not constitute an enoineers or architects approval but is considered a short cirawinn for installation purposes of Reliance Electric. Sheet Number: FA 7 Floor 3 SLC Smoke Control Plan `futio QQ Standar Standard Standard Corridor IF �. Floor 5 SLC4 SLC4 SLC4 Floor 5 Floor 3 n AMP7,8 FAPP12 FAPP13 FAPP14 FAPP15 4th Floor Fire Sprinkler Flow/Tamper monitor. Floor 5 SG Sr Floor 3 Floor 3 Stud'o �dioK Studio 435 Sta r #2 SLC4 L-- Floor 3 SLC4 Studio QQ 425 Elev. Lobby Floor 5 Studio QQ tudio QQ S udio QQ Studio QQ tudio K Studio K udio QQ Studio K Studio K 409 Studio K SLC4 SLC4 Standard -K SLC4 Standard K Stair #1 Floor 5 Floor -5 0 J Studio QQ 427 1 -Bed 429 NORTH Floor 4 SLC and Smoke Control Plan SCALE: 1 /8" = 1' V 2' 4' 8' 16' 32' CI) .5.1 RI 44 co - 0 Q N ▪ MINIM CO L Lf) T-"" LC) O 6) M CV O Co 0 0 CO 0 0 0 n� a) a) a E O U E C a) U CO C L�' ) Co 0) d- N awn Bv: EJB Checked By: JPJ Job #: 1903 Revisions: # Date Revision Notes 0 2018/12/26 Original Drawing 1 2019/04/23 Changes for Smoke Control / HVAC Coordination 2 2019/05/08 Device relocations per Owner 3 4 5 6 7 8 9 10 11 12 Engineers Stamp: Drawing/Document prepared by: Ephriam J. Bistline NICET Certification No. 136272 Fire Alarm Systems - Level IV Certification Expires: 05/01/2019 This Drawing is the exclusive Property Of Reliance Electric, and was prepared for the exclusive use of Reliance Electric and its affiliates, for the services performed by Reliance Electric. No use, reproduction or duplication of this drawing or associated documents, in part or whole may be made without the written consent of Reliance Electric. This Drawing does not constitute an engineers or architects approval but is considered a shnn drawinn for installation purposes of Reliance Electric. Sheet Number: FA -8 Floor 4 SLC & Smoke Control Plan tudio SLC5 L[§1 Floor Guest Laundry Floor 4 Floor 4 SLC5 SLC5 FAPP19 NAC4 9 H F-PHLNE 111 FP sr4 iiL' c Floor4 FACP2I SLC cables to and u from the FACP sha tte routedno alesalffa i 6' apart. L — = /Tamper monitor. Floor Fire Sprinkler FAPP16 FAPP17 FAPP18 FAPP19 Studio Stand rd K L Stair #2 St.ndard K dio as Floor 4 F PHONE F -PHONE St dio QQ Studio Q 1 1 Studio QQ K 513 Studio Studio QQ Studio K IADAS SLC5�� Standar. K Floor Stair #1 Floor 4 Floor 4 NORTH Floor 5 SLC and Smoke Control Plan SCALE: 1/8" = 1' ,, AIME'//,,,,,,, A Iii , i/ 2' 4' 16' 32' J Li) O 6) N QM W 0 CO 0 O 0 `) d) 0 awn By: EJB Checked By: JPJ Job #: 1903 Revisions: # Date Revision Notes 0 2018/12/26 Original Drawing 1 2019/04/23 Changes for Smoke Control / HVAC Coordination 2 2019/05/08 Device relocations per Owner 3 4 5 6 7 8 9 10 11 12 Engineers Stamp: Drawing/Document prepared by: Ephriam J. Bistline NICET Certification No. 136272 Fire Alarm Systems - Level IV Certification Expires: 05/01/2019 ZI , r This Drawing is the exclusive Property Of Reliance Electric, and was prepared for the exclusive use of Reliance Electric and its affiliates, for the services performed by Reliance Electric. No use, reproduction or duplication of this drawing or associated documents, in part or whole may be made without the written consent of Reliance Electric. This Drawing does not constitute an engineers or architects approval but is considered a shnn drawl nn for installation purposes of Reliance Electric. Sheet Number: FA -9 Floor 5 SLC Smoke Control Plan Outside Air Supply Shaft to Corridors ! i 1 AHU- _ 1 Floor 5 0 00 Floor 2 e I Floor 5 Elevator Hoistway Vent Damper See Smoke Control Riser (FA -4) for device functions. Coordinate with mechanical smoke control drawings and mechanical contractor on to ensure all required smoke control functions are performed. LJ o 2 0 0 See Smoke Control Riser (FA -4) for device functions. SPF -1 RTU -1 Floor 5 Coordinate with mechanical smoke control drawings and mechanical contractor on to ensure all required smoke control functions are performed. Floor 5 Floor 5 SEF -1 SEF -3 0 0 H - sc---0. Floor 5 Hal RTU -2 SPF -2 10 Floor 5 Floor 5 fl rH reTI Floor 5 SC See Smoke Control Riser (FA -4) for device functions. Coordinate with mechanical smoke control drawings and mechanical contractor on to ensure all required smoke control functions are performed. SEF -2 11 NORTH Roof SLC and Smoke Control Plan SCALE: 1/8" = 1' 2' 4' 8' 16' 32' E E co a) Lo 9 C\1 CO 0 co Cs L.- LO 0 CO —0- 0 0) a) c a) C\1 0 awn By: EJB Checked By: JPJ Job #: 1903 Revisions: # Date Revision Notes 0 2018/12/26 Original Drawing 1 2019/04/23 Changes for Smoke Control / HVAC Coordination 2 2019/05/08 Device relocations per Owner 3 4 5 6 7 8 9 10 11 12 Engineers Stamp: Drawing/Document prepared by: Ephriam J. Bistline NICET Certification No. 136272 Fire Alarm Systems - Level IV Certification Expires: 05/01/2019 This Drawing Drawing is the exclusive Property Of Reliance Electric, and was prepared for the exclusive use of Reliance Electric and its affiliates, for the services performed by Reliance Electric. No use, reproduction or duplication of this drawing or associated documents, in part or whole may be made without the written consent of Reliance Electric. This Drawing does not constitute an enaineers or architects annmval hilt ic rrtneirictreari n cl-trin rirtalirtel for installation purposes of Reliance Electric. Sheet Number: FA 1 0 Roof SLC Smoke Control Plan I ri Pool/Spa 2W 2W Vestibule Studio K ADA RIS Studio QQ rir 128 1, FAPP NAC1 tan da I 1138 nJ Standa Standar © Standard K_ ADA RIS 144 SPKR SPKR 14 IT 1W NAC4 NAC4 NAC4 NAC4 NACI LQ 1-10 NAT=A '‘ANAL 15 _ CI Hri TI - , I SPKR -z-‘- -)`1 SPKR Corridor IL ! = 0 SPKR NAC3 SPKR NAC3 SPKR NAC3 SPKR NAC3 SPKR NAC3 SPKR NAC3 SPK SPKR NAC3 SPKR NAC3 SPKR NAC3 SPKR NAC3 SPKR NAC3 SPKR NAC3 SPKR NAC3 NAC3 SP 75 WVVP Pool Equip. Pool HVAC NAC3 J RAO SPKR WWiroom SPKR SPIT Ice NAC3 15 1W 4V# 30 1W SPKR AMF2 PKR2 1W\ FAPP' NAC3 SPKR NAC3 1W Linen Room Mechanical a_ a_ u. SPKR CC! FAPP2 NAC1 1W NAC4 111 "RAC -I NAC4 JAIL -H-- Stair #2 75 1W C C/1 = Et Fitness Laundryo / 30 30 NAC3 C/3 75 1W C NAC3 SPKR SPXR IL Unisex Linen Electrical 15 NAC3 FAPPt NAC1 AMP1 SPKR1 iw 1=M-- FAPP1 NAC3 30 Lt lo=m PBX / 1 Server/Tel r NAC RAC SPKR FAPP1 NAC2 Sales reak Room SPKR SPKR NAC2*-----7-- RAC NAC2---- SPKR 15 SPKR 15 1W SPKR MEL_ NAC2 1W Tele Conf. SPKR NAC2 15 FSCP I IFACP1 15 1W SPKR 15 1W 15 MACI SPKR 1W Office Admin 0 0 Reception 30 1W ( Luggage t 1W 30 SPKR Lobby a a a 11111111111 See FA- .2 for srriok detector coverage in the( fae. Go Go Go MAC Oltr 75 0411)0000 1)111110 0 0 E SPKR 15 1W NAC2 SPKR Bar Storage SPKR t Corridor SPKR HVAC IR 12 30 sc,i5 Womens Lit 0 0 riiv '11.* MAC 30 Mens f r SPAR SPKR 1W 15 1W Storage 30 vu iffis4 SPKR 15 SPKR NAC2 1W C/3 SPKR SPKR NACI - SPKR NACI Breakfast I 1 I I I 11 II 11 Stair #1 Re -Store Vestibule Meeting UP SPIT NACI ST -1 AV 1 -Bed 129 Studio K 131 Studio K 133 Floor 1 Notification SCALE: 1/8" — 1' NORTH Studio K 135 Standard K 137 2' 4' 8' 16' 32' Standard K 139 Studio QQ ADA 141 Ia CO 9 a) CN CO 0 Ti CO 0 a) a) awn By: EJB 12 Checked By: JPJ Job #: 1903 Revisions: Date Revision Notes 2018/12/26 Original Drawing 1 2019/04/23 Changes for Smoke Control / HVAC Coordination 2 2019/05/08 Device relocations per Owner 3 4 5 6 7 8 9 10 11 12 Engineers Stamp: Drawing/Document prepared by: Ephriam J. Bistline NICET Certification No. 136272 Fire Alarm Systems - Level IV Certification Expires: 05/01/2019 Z.------:;,—__ This Drawing is the exclusive Property Of Reliance Electric, and was prepared for the exclusive use of Reliance Electric and its affiliates, for the services performed by Reliance Electric. No use, reproduction or duplication of this drawing or associated documents, in part or whole may be made without the written consent of Reliance Electric. This Drawing does not constitute an enaineers or architects approval Put iR nnnsiriprpri a Chnn tirautfi nn for installation purposes of Reliance Electric. Sheet Number: Floor 1 Fire Alarm Notification Plan O� rr, Stand41 Standar NAC4 SPKR CCI NACI 110 NAC4 SPKR- FAPP7 NAC4 FAPP6 NAC4 `NAC3 NAC3 SPKR SPKR NAC3 NAC3 NAC3 NAC3 NAC3 SPKR SPKR SPKR SPKR SPKR NAC3 NAC3 NAC3 NAC3 NAC3 SPKR SPKR SPKR SPKR SPKR NAC3 NAM i frn. 1 NAC3 NAC3 NAC3 NAC3 NAM NAC3 NAC3 SPKR SPKR SPKR SPKR SPKR SPKR SPKR SPKR SPKR r CI EL J<< ) FAPP6 NAC1 FAPP7 NAC3 SPKR SPKR AM P3 SPKR1 NAC4 APP4 NAC3 NAC4 NAC4 ommons Suite Stair #2 Star dard K Studio QQ Studio QQ 1 -Bed EI- . L. •b L. 219 1w >--SPKR SPKR SPKR / NACI NACI NACI 30 FAPP5 ( NAC3 NACI NACI NACI J CPKG ll i 1 -Bed 229 Studio K 231 Studio QQ 217 11 Studio QQ Studio QQ 216 Studio K Studio K 0 0 Studio K Studio K Tip 208 Studio K _APP4. NACI dard K tandarK T 1 -Bed ADA NORTH Studio K 233 Floor 2 Notification SCALE: 1 /8" = 1' Studio K 235 Standard K 237 2' 4' 8' 16' 32' 11, II%It, RI 44 co •% a_ L 4795 Oakland Street LC) O C� C1) C\1 Co MO 0 CO 0 0 U W n� C1) 0 E 0 0 E 03 Ci) W U • Co �) V Co CTV C3) CDJ awn Bv: EJB , Checked By: JPJ Job #: 1903 Revisions: # Date Revision Notes 0 2018/12/26 Original Drawing 1 2019/04/23 Changes for Smoke Control / HVAC Coordination 2 2019/05/08 Device relocations per Owner 3 4 5 6 7 8 9 10 11 12 Engineers Stamp: Drawing/Document prepared by: Ephriam J. Bistline NICET Certification No. 136272 Fire Alarm Systems - Level IV Certification Expires: 05/01/2019 This Drawing is the exclusive Property Of Reliance Electric, and was prepared for the exclusive use of Reliance Electric and its affiliates, for the services performed by Reliance Electric. No use, reproduction or duplication of this drawing or associated documents, in part or whole may be made without the written consent of Reliance Electric. This Drawing does not constitute an engineers or architects aooroval but is considerP-f a shnn drawinn for installation purposes of Reliance Electric. Sheet Number: FA -12 Floor 2 Fire Alarm Notification Plan _ yeio K NAC4 dard K 1 I Stand, rd Standard K tandard K SPKR CCI FAPP9 NAC1 SPKR L ,w • s I 1,o Temiio NAC4 SPKR SPKR � f ---SPKR-- Corridor NAC2-- NAC2-- NAC2---- NAC2--- NAC2-'-- NAC2 SPKR SPKR SPKR SPKR SPKR SPKR G2-- NAC2- NAC2 NAC2 NAC2 NAC2-- NAC2- NAC NACI— NAC2- NAC2' NAC2- NAC SPKR SPKR SPKR SPKR SPKR SPKR SPKR SPKR SPKR SPKR SPKR SPKR SPKR SPKR NAC2 IAC2 NAC2 NAC2 NAC2 NAC2 NAC SPKR SPKR SPKR SPKR SPKR SPKR SPKR SPKR AMP1 to'WNV' / SPKR1 FAPP10 NACI FAPP11 NAC2 I� AMP5 SPKR1 NAC4 SPKI 1 SPKR FAPP8 NAC4 SPKR 'iii SPKR FAPP8 NAC1 NAC4 Betr. Lobby FAPP8 NAC1 ' 4 -041110 SB „ dYIAM NACI C4 NAC2 NAC4 Standard K Stair #2 NAC4 ' NACI NAC4 Studio QQ 325 Studio QQ 327 1 -Bed 329 Studio K SPKR NACI SPKR NACI SPKR NACI NACI NACI - NACI SPKR 331 FAPP9— FAPP9 Studio QQ St dio QQ Studio QQ ADA TS Studio K Studio K dio K Studio K FAPP9 NAC2 Studio K FAPP 1w NAC Standard K Sta dard K NAC4 Stair #1 NORTH Studio K 333 Floor 3 Notification SCALE: 1 /8" = 1' Studio K 335 7 2' 4' 8' 16' 32' NAC NAC4 NACI NAC4 �l 1 tudio QQ ©-- Studio Q t--I--r—; 0 4) (1) -o co 0 V , ti L.r) LC) L O TT� C ) N 00 0 D co O O 0 a\) Q) 0 E O U E co W U awn By: EJB Checked By: JpJ Job #: 1903 Revisions: # Date Revision Notes 0 2018/12/26 Original Drawing 6 2019/04/23 I 6 2019/05/08 Device relocations per Owner 3 4 i Betr. Lobby FAPP8 NAC1 ' 4 -041110 SB „ dYIAM NACI C4 NAC2 NAC4 Standard K Stair #2 NAC4 ' NACI NAC4 Studio QQ 325 Studio QQ 327 1 -Bed 329 Studio K SPKR NACI SPKR NACI SPKR NACI NACI NACI - NACI SPKR 331 FAPP9— FAPP9 Studio QQ St dio QQ Studio QQ ADA TS Studio K Studio K dio K Studio K FAPP9 NAC2 Studio K FAPP 1w NAC Standard K Sta dard K NAC4 Stair #1 NORTH Studio K 333 Floor 3 Notification SCALE: 1 /8" = 1' Studio K 335 7 2' 4' 8' 16' 32' NAC NAC4 NACI NAC4 �l 1 tudio QQ ©-- Studio Q t--I--r—; 0 4) (1) -o co 0 V , ti L.r) LC) L O TT� C ) N 00 0 D co O O 0 a\) Q) 0 E O U E co W U awn By: EJB Checked By: JpJ Job #: 1903 Revisions: # Date Revision Notes 0 2018/12/26 Original Drawing 1 2019/04/23 Changes for Smoke Control / HVAC Coordination 2 2019/05/08 Device relocations per Owner 3 4 5 6 7 8 9 10 11 12 Engineers Stamp: Drawing/Document prepared by: Ephriam J. Bistline NICET Certification No. 136272 Fire Alarm Systems - Level IV Certification Expires: 05/01/2019 This Drawing is the exclusive Property Of Reliance Electric, and was prepared for the exclusive use of Reliance Electric and its affiliates, for the services performed by Reliance Electric. No use, reproduction or duplication of this drawing or associated documents, in part or whole may be made without the written consent of Reliance Electric. This Drawing does not constitute an enaineers or architects approval but is consirlarAri a chnP drawin for installation purposes of Reliance Electric. 9 Sheet Number: FA -13 Floor 3 Fire Alarm Notification Plan NAC4 NlIC4 NAC4 Standar 43.8 Standard Standard andard K ADA TS r� NAC4 NAC4 NAC3 AMP8 FAPP14 SPKR1 NAC4 i 1 - ___/ , 1 �LJ JI J oo �I - `J FAH QVAC3 Corridor 0 0� 400 =PP12 110 .-_1w ®©SB .NAC4 II SPKR Engineer's Office 421A 110 1w .,W# 1w15 l SPKR SPKR SPKR SPKR SPKR SPKR SPKR ( 1w 15 NAC2---- NAG NAG2 NAC2--- NAG2 NAC2- NAC c SPKR 2 NAC2 SPKR SPKR SPAR SPAR SPKR S KR 1w15 NAC NAC2-- NAG2---- NACU NAC2' N C2 {1c SPKR SPKR SPAR SPKR SPKR SPKR SPKR NAG? NAG NAC2--- NAG? NAC2-- NAG NAC2 SPKR SPKR SPKR SPAR SPKR SPAR SPAR NAG NAG NAG NAC NAC2-- NAC2NAG AC2 SPKR AMP7 SPKR1 NAG' FAPP12 FAPP13 FAPP14 FAPP15 FAPP15 NAC4 --FAPP13 Linen FAPP15 _ = � 1 421 NAC2 SPAR CCI SPKR CCI SPKR SPAR NAC4 NAC4 NAC4 NAN NAC4 NAC4 Stair #2 tandard K F Elev. Lobby 419 SPKR SPKR SPKR NACI NACI NACI NACI NACI PAPP -1 NAC1 FAPP1; NAC4 tudio QQ 418 S udio QQ 416 Studio QQ Studio QQ Studio K 413 Studio QQ 425 1wiio Studio K Studio K FAPP13 NAC3 Studio K Stair #1 Studio QQ 427 1 -Bed 429 NORTH Floor 4 Notification SCALE: 1/8" = 1' / 2' 4' 8' 16' 32' Co L 0 L.r) L N W O L vJ CO CZ p - U CO W L /^ W gq- Q E O V E nO W W U co awn By: EJB Checked By: JpJ Job #: 1903 Revisions: # Date Revision Notes 0 2018/12/26 Original Drawing 1 2019/04/23 Changes for Smoke Control / HVAC Coordination 2 2019/05/08 Device relocations per Owner 3 4 5 6 7 8 9 10 11 12 Engineers Stamp: Drawing/Document prepared by: Ephriam J. Bistline NICET Certification No. 136272 Fire Alarm Systems - Level IV Certification Expires: 05/01/2019 Z-g,'4v--- This Drawing is the exclusive Property Of Reliance Electric, and was prepared for the exclusive use of Reliance Electric and its affiliates, for the services performed by Reliance Electric. No use, reproduction or duplication of this drawing or associated documents, in part or whole may be made without the written consent of Reliance Electric. This Drawing does not constitute an engineers or architects aooroval hilt is rtnnciriarari 9 chr,r, dr,..,;.,,, for installation purposes of Reliance Electric. Sheet Number: FA 14 Floor 4 Fire Alarm Notification Plan 1 -Bed Standa Standee C.andard K FAPP17 =NAe4 P. NAC4 NAC4 FAPP17 .NAC2 NAC4 Corridor NAC4 1w y15 SPAR SPAR SPKR SPAR SPKR SPKR SPKR \ 1W 15 SPKR SPAR SPAR SPAR SPAR SPAR SPAR SPAR 1W 15 `� SPAR SPAR SPAR SPKR SPAR SPAR SPAR ►�+C NACI NACI NACI NACI NACI NACI NACI � NACI NACI NACI NACI NACI - NACI NACI NACI c I NACI NACI NACI MO NACI NACI NACI i SPAR SPAR SPAR SPAR SPAR SPKR SPAR NACI NACI NACI NACI NACI NACI NACI SPAR- SPKR SPKR- FAPP18 NAC2 FAPP17 Guest Laundry PKR SPKR FMP9,10I FAPP16 FAPP17 FAPP18 FAPP19 FAPP19 NAC4 AMP9 -SPKR1 NAC4 !.`iV .. NACI NAC4 Elev Lobb NAC4 NAC4 Studio I Stand rd K Stair #2 SPAR SPKR C2 --NAC2 SPAR NAC2 NAC2-- NAC NAC tudio QQ Studio QQ 517 Studio QQ 515 Studio K Studio QQ 525 Studio K Studio QQ Studio K ADA TS 510 I Studio K 509 Studio K 507 I041 1W N C4 w Stair #1 ST -1 2 -Bed H i.' 502 8 Studio QQ 527 1 -Bed 529 J Studio K 531 NORTH Floor 5 Notification SCALE: 1/8 1' 2' 4' 8' 16' 32' 1t) ct T, 4", (I) L V Lc.) O cr) 1 C) N Q CO 0 0 CO 0 0 U a) W` a) 0 E 0 E a)o W U .`V a) 0 Lt) Co N C Q N awn By: EJB Checked By: JpJ Job #: 1903 Revisions: # Date i 1 pr J 2018/12/26 Original Drawing r I ( Changes for Smoke Control / HVAC Coordination 2 2019/05/08 Device relocations per Owner 3 Elev Lobb NAC4 NAC4 Studio I Stand rd K Stair #2 SPAR SPKR C2 --NAC2 SPAR NAC2 NAC2-- NAC NAC tudio QQ Studio QQ 517 Studio QQ 515 Studio K Studio QQ 525 Studio K Studio QQ Studio K ADA TS 510 I Studio K 509 Studio K 507 I041 1W N C4 w Stair #1 ST -1 2 -Bed H i.' 502 8 Studio QQ 527 1 -Bed 529 J Studio K 531 NORTH Floor 5 Notification SCALE: 1/8 1' 2' 4' 8' 16' 32' 1t) ct T, 4", (I) L V Lc.) O cr) 1 C) N Q CO 0 0 CO 0 0 U a) W` a) 0 E 0 E a)o W U .`V a) 0 Lt) Co N C Q N awn By: EJB Checked By: JpJ Job #: 1903 Revisions: # Date Revision Notes 0 2018/12/26 Original Drawing 1 2019/04/23 Changes for Smoke Control / HVAC Coordination 2 2019/05/08 Device relocations per Owner 3 4 5 6 7 8 9 10 11 12 Engineers Stamp: Drawing/Document prepared by: Ephriam J. Bistline NICET Certification No. 136272 Fire Alarm Systems - Level IV Certification Expires: 05/01/2019 This Drawing is the exclusive Property Of Reliance Electric, and was prepared for the exclusive use of Reliance Electric and its affiliates, for the services performed by Reliance Electric. No use, reproduction or duplication of this drawing or associated documents, in part or whole may be made without the written consent of Reliance Electric. This Drawing does not constitute an engineers or architects annrnval hnt is r nnciriararl n 0E,.,,, a...,:.,,. for installation purposes of Reliance Electric. Sheet Number: FA -15 Floor 5 Fire Alarm Notification Plan , Revisions: # Date Revision Notes 0 2018/12/26 Original Drawing 1 2019/04/23 Changes for Smoke Control / HVAC Coordination 2 2019/05/08 Device relocations per Owner 3 SOUTH WINGEAST WING 5 6 DESCRIPTION OF OPERATION ® SYSTEM NORMAL 9 10 EQUIPPED WITH STAIRWELL 12 i Engineers 0 ELEVATOR LOBBY SMOKE 0 SMOKE DETECTOR Drawing/Document prepared by: Ephriam J. Bistline NICET Certification No. 136272 Fire Alarm Systems - Level IV Certification Expires: 05/01/2019 THIS BUILDING IS PRESSURIZATION AND CORRIDOR EXHAUST. V, Al// • . East Wing 0 HEAT DETECTOR DUCT DETECTOR A FIRE EVENT ANYWHERE IN THE BUILDING WILL: - ACTIVATE FULL BUILDING ALARM - ACTIVATE STAIRWELL PRESSURIZATION SYSTEMS CLOSE ALL FIRE DOORS CLOSE HVAC DAMPERS NOT ASSOCIATED WITH SMOKE CONTROL c South Wing Elevator Stair #2 t Elevator Stair #2 O WATERFLOW © MANUAL STATION ® POWER DISCONNECT GENERATOR RUNNING - ACTIVATE CORRIDOR EXHAUST ON ALL FLOORS / Stair #1 Stair #1 \ NORTH NORTH SOUTH WING CORRIDOR EXHAUST AUTO ON.� I�� OFF 4�� ©0 ON OFF FAULT STAIR PRESSURIZATION AUTO ON 010 © ON OFF #1 l� OFF 0 FAULT ELEVATOR VENT AUTO OPEN t41" C. OPEN CLOSED HOISTWAY DAMPER j1 CLOSE 0 FAULT z�,WI IiiVt) y� — 'kv- STAIR #2 PRESSURIZATION AUTO ON . OFF t_101;4. © 0 ON OFF FAULT EAST WING CORRIDOR EXHAUST AUTO ONj� OFF til#4- © 0 ON OFF FAULT Outside Air Supply to Corridors SPF -1 SPF -2 SEF -1 © OPEN © OPEN SEF -3 © OPEN OPEN © SEF -2 0 CLOSED 0 CLOSED QR CLOSED FLOOR CONTROL CLOSED Q FAULT \\A FAULT FAULT FAULT / DUCT DETECTOR / 1 DUCT DETECTOR ---\\I\\`\— ` © OPEN OPEN © © OPEN — \`\\ © OPEN WATERFLOW 0 EXHAUST OPEN r � SMOKE DET 0 AUTO --� ® CLOSED FLOOR 5 FLOOR 5 CLOSED O -- FAULT CORRIDOROFF CLOSED Q FAULT 0 CLOSED FAULT —� 0 CLOSED FAULT LVL 5 PULL STATION R CORRIDOR FAULT © OPEN OPEN © © OPEN © OPEN WATERFLOW 0 EXHAUST �N OPEN SMOKE DET 0 �� AUTO —� O CLOSED FLOOR 4 CLOSED 0 O CLOSED ---------0 CLOSED FLOOR 4 CLOSED Q -- CORRIDOR FAULT FAULT FAULT FAULT LVL 4 PULL STATION © v', OFF CORRIDOR FAULT © OPEN OPEN © ® OPEN © OPEN WATERFLOW OR EXHAUST OPEN © FLOOR SMOKE DET O I •- AUTO —� O CLOSED 3CLOSED CORRIDOR FAULT R O FAULT i � R CLOSED 0 FAULT — ` R O CLOSED < ` FAULT 7 LVL � PULL STATION 0 3 OFF FLOOR 3 CLOSED R CORRIDOR FAULT i © OPEN Elevator OPEN © © OPEN © OPEN WATERFLOW QR EXHAUST OPEN Alternate Recall SMOKE DET 0 CO •AUTO R CLOSED FLOOR 2 Floor CLOSED O O FLOOR 2 CLOSEDFAULT R CORRIDOR FAULT R j FAULT \ R CLOSED O FAULT —� R CLOSED FAULT LVL 2 PULL STATION 0 OFF CORRIDOR �— G OPEN Osmoke Motorized door for corridor exhaust air intake Elevator © OPEN WATERFLOW 0 EXHAUST Makeup air intake for corridor OPEN FLOOR Prima Recap SMOKE DET ORO • AUTO smoke exhaust system -� © CLOSED 1 FAULT CORRIDOR — I Floor -` 0 CLOSED FAULT LVL 1 PULL STATION 0 OFF FLOOR 1 CLOSED OR j- CORRIDOR FAULT / STAIR #1 \ ELEVATOR STAIR #2 © OPEN 0 CLOSED FAULT OPEN © CLOSED 0 FAULT \0 LAMP TEST OVERALL MANUAL OVERRIDE ON CO OFF SOUTH WING EAST WING CI) RI 44 co 4% n QUO rilo% "% T. LC) Lf) O 9 4) M N O 00 Q) L O-E-r 13 Cs2 c _O CO p -U Co O 45 - Lf) C awn By: EJB Checked By: JPJ Job #: 1903 Revisions: # Date Revision Notes 0 2018/12/26 Original Drawing 1 2019/04/23 Changes for Smoke Control / HVAC Coordination 2 2019/05/08 Device relocations per Owner 3 4 5 6 7 8 9 10 11 12 Engineers Stamp: Drawing/Document prepared by: Ephriam J. Bistline NICET Certification No. 136272 Fire Alarm Systems - Level IV Certification Expires: 05/01/2019 This Drawing is the exclusive Property Of Reliance Electric, and was prepared for the exclusive use of Reliance Electric and its affiliates, for the services performed by Reliance Electric. No use, reproduction or duplication of this drawing or associated documents, in part or whole may be made without the written consent of Reliance Electric. This Drawing does not constitute an engineers or architects annrnval hitt is nonciriarar1 n chrm d yawi for installation purposes of Reliance Electric. ng ly Sheet Number: FA -16 Smoke Control Panel Detail GIS- 1 lJout W-_. CORRIDOR 500 CORRIDOR 400 I CORRIDOR 300 CORRIDOR 200 1 23 12" DI OR INDUSTRY DRIVE PROPOSED BUILDING FFE: +0-00 HORN STROBE. FIRE SPRINKLER FLANGE G Al e" DI FLOW INFO. DATE PERFDRMSD: 12/47/2018 PERFORMED B7 Tukwila Public Work. STATIC PRESSOR& 160.0 Pal 1 LOWEIS 125.0 PSI 8001 GPM 12" DI WASHINGTON ATE CERTIFICATE OF COMPETENCY FIRE PROTECTION INKLER SYSTE Site ID C building Section SCALE: NONE FDC LOCATION 5" STORZ CONNECTION W/ 30• ANGLE DEN n SCALE: NONE 12" DI COR IDOR 124 GENERAL NOTES STRUCTURE: c EXTERIOR WALLS ARE TO BE STEEL STUDS OR WOOD c INTERIOR WALLS TO BE WOOD WITH GYPSUM BOARD OR BLOCK. CRITERIA: • BUILDING TO BE PROTECTED BY A WET PIPE SYSTEM DESIGNED TO NFPA-13, 2019 • ALL PIPING SYSTEM TO BE HYDROSTATICALLY TESTED AT 200 PSI FOR 2 HOURS. C ALL TESTS TO BE WITNESSED BY THE FIRE DEPARTMENT ALL CONTROL VALVES TO HAVE TAMPER SWITCHES. MATERIALS: O ALL MATERIALS TO BE NEW AND MEET NFPA, U.L. AND FM STANDARDS. o ALL HANGERS TO BE IN ACCORDANCE WITH NFPA-13, 2019 STANDARDS. C STEEL PIPING TO BE SCH.10 AND SCH.40 INSTALLATION • ALL ELEVATIONS ARE TAKEN FROM TOP OF FINISHED FLOOR (ASSUME 0'0"). O FIRE DEPARTMENT VALVES. AND DRAINS SHALL BE READILY ACCESSIBLE AT ALL TIMES. PROVIDE 36" CLEARANCE. SYMBOLIZES HYDRAULIC CALCULATION REFERENCE POINTS. TO SOURCE 8" U U- 0 tzt- 8" T 0 J 5 m O C%ALE: NOW VALVE PIT DETAIL Fire Permit Number l-S-� To schedule; in,p ion s coif 206-575-4407 " CO 11T U fNSITE ADA \i/ SPRINKLER PIPE H. MBE EIRAP FOOD FROND NGER DETAIL GALE: NONE HANGER NOTE: SPACING — STEEL PIPE 1 — 114 EVERY 12'- 112 — LARGER EVERY 15'— HANGER NOTE: SPACING — CPVC PIPE 1 114 112 2 EVERY 6'-0" EVERY 6'-6" EVERY 7'-0". EVERY 8'-0" HANGER NOTE: SPACING — CPVC PIPE HEAD DROP END LINE ELBOW 1 114 112 — 2 12" MAX. 16" MAX. 24" MAX. HANGER NOTE: SPACING CPVC PIPE HEAD DROP INLINE TEE 1 14 112 — 2 R ❑ Without Comments -g As Noted in Red Per The Attached Letter These plans have hen reviewed by The Tukwila Fire Prevention Bureauconformance with current City c'I:andards. Accepta.c,:;:e: subject to errors and omissions which (..<.; a thon•ize violations of adopted c:tandards and ordimanccs. Me responsibility for the adequacy of design to a iy the designer. Additions, deletions o:revi::io rs to these drawings after this date will void tip:; :. tE9ce and will require a resubmittal ofe;.... i)ssequent approval. Final acceptance is sub act ix i eid test and inspection by The Tukwila Fire Prevention Bureau. /5 5'—O" MAX. 6'-0" MAX. 7'-0" MAX. 1. 8" OS&Y (BY OTHERS) 2. 8" DOUBLE CHECK (BY OTHERS) 3. FLOW SWITCH 4. PRESSURE GU AGE 5_ 2" INSPECTORS TEST AND DRAIN VALVE 6. HYDRAULIC NAMEPLATE 7. SPARE HEAD CABINET 8. 4" CHECK VALVE FOR FDC (BY OTHERS) 9. SUPERVISED BUTTERFLY VALVE 10. 8X6 REDUCER 11. 5" STORZ FDC W/30o ANGLE DOWN (BY OTHERS) AND PROVIDE A WATERPROOF RISER ZONE MAP. 12. PROVIDE RISER ZONE MAP C RISE DETAIL %ALE: NONE ROOF 56' - 1 114" LEVEL 5 ' 11 44 '- 44' - 11' LEVEL 3 24' -11 " 00 -- LEVEL 1 0" FOUNDATION -10" NIBCO INDICATOR 4- POST ASSEMBLY 90 W/BALL DRIP 2 DRAIN UNE 150' HOSE CABINET 1-3/4 DOUBLE HOSE WI 1-1/2 NST COUPLING FWE DEPARTMENT USE ONLY. 5TH FLOOR U 4TH FLOOR 150' HOSE CAMET 1-3/4 DOUSE HOSE W/ 1-1/2 NST COUPLING FFE DEPARTMENT USE ONLY. 3RD FLOOR 2ND FLOOR I I HI COMBINATION STANDPIPE SCALE 1/4"=1'—O" 4" COMBINATION STANDPIPE BACK TO WATER SERVICE WITH ISOLATION VALVE 2" MAIN DRAIN TO OUTSIDE 1ST FLOOR S.I.N HEAD NOTES SYM. NO. PIPING DESCRIPTION REVISIONS DATE VK462 VK458 VIKING VK462 5.6 1/2" 155' WHITE PENDENT CONCEALED 227 PENDENT ON CONCEALED PIPING CONCEALED WHITE ESC. VIKING VK458 7.4 3/4" 155' WHITE PENDENT 20X20 540 PENDENT ON CONCEALED PIPING SEMI—RECESSED WHITE ESC. VK305 VIKING VK305 5.6 1/2" 155' WHITE SIDEWALL 75 SIDEWALL ON CONCEALED PIPING SEMI—RECESSED WHITE ESC. a TOTAL FIRE PROTECTION INC. 1004 7TH AVE. NORTH P.O. BOX 680 BRANDON SD. 5705 (605) 582-2400 e—mail: cbrandt©tfpsd.com VK460 VK302 VK302 VIKING VK460 5.8 1/2" 155' WHITE SIDEWALL 16x16 16x20 1/6dwn VIKING VK302 5.6 1/2" 155' WHITE PENDENT VIKING VK302 5.6 1/2" 155' WHITE PENDENT. 'ENT COATING 00 138 86 22 SIDEWALL ON CONCEALED PIPING PENDENT ON CONCEALED PIPING PENDENT ON CONCEALED PIPING SEMI—RECESSED WHITE ESC. SEMI—RECESSED WHITE ESC. SEMI—RECESSED WHITE ESC. DESIGN INSTALLER OWNER A A A OVA,kL keT'ECTION 1004 7TH AVE. NORTH P.O. BOX 680 BRANDON SD. 57005 (605) 582-2400} DEMMER: GREG OLM NTT L.. Ffft H TECTION 1004 7TH AVE NORTH P.O. BOX 680 BRAIMON SD. 57C (605) 582-2400 BkISTALLER Element By Westin 515 Industry Drive Tukwila, WA 99188 71'84 .... w O'.. w w. w.www C -eg m Level III DRAWN BY: GREG LINDHOLM DATE 5-7-19 TOTAL A.S. 1088 SCALE: AS NOTED CHECKED BY: SHEET NO. 1 OF 6 FIRE PREVENTION DIVISION 5A 0 Remote Area 4 Rowing Heads 11 Start Head PSI 127 Start Head GPM 130 SQFT per Head 130 Wet / Dry WET Hazard Ord. Grp. 1 Code NFPA 13 Construction Density 0.150 Area 1138 Len/Wid Ratio 1.20 Max Velocity 20.6 Elev-Hd to Riser (') 240 PSI -Hd to Riser &66 Source Name or Location Source PSI Avail at Source 150 PSI Req'd at Source 123 Safety PSI 26.8 GPM Req'd at Source 482 Duration of Source 0.000 Req'd Source Volume 0.000 Inside Hose 0.000 Outside Hose 250 Pressure Summary Available Pressure of 149.9 psi Exceeds Required Pressure of 123.1 psi This is a safety margin of 26.8 psi or 18 % of Supply Advanced Summary Max Density Available 0.166 GPM at Max Available Density 532 PSI loss - TOR to Source 4.74 Rack Demand 0.000 REQUIRED MATCH LINE MATCH LINE WASH) TON STATE CERTIFICATE OF COMPETENCY FIRE PROTECTION SPRINKLER SYSTE 2 2 I l' 6 ; Cil 11=42' Source Name or Location Source PSI Avail at Source 150 PSI Req'd at Source 133 Safety PSI 16.4 2 i 01 I IPSI loss - TOR to Source 5.83 Rack Demand 0.000 o 3-2 of (408� ■ 407 4 11 114 ■ 112 2-4'r 10-0 N C2 2 2 I I 6 2 11=42' Source Name or Location Source PSI Avail at Source 150 PSI Req'd at Source 133 Safety PSI 16.4 2 3-4 - 7-612 o_i 4-312 IPSI loss - TOR to Source 5.83 Rack Demand 0.000 o 3-2 of 30-31 ■ '■ 4% .ES] (Inc ■ i EN RE ammo maimE1111 fim-21,WELPTEIN WIN -■i�" ■I indi _M■ r_ II MIL►' > C■! E► `�'. MI wzmoll. NMI ow o ' 116,I, �� ' �e .,:=' �;-� tail MP Me - ■,moi ■�i�. ��. _ �■_ 6-512 10'-0" 1-0 UNISEX RR o® • ARDROO 109 7J Wet / Dry WET Hazard Ord. Grp. I Code NFPA 13 Construction 11' - 8" 11 11=42' Source Name or Location Source PSI Avail at Source 150 PSI Req'd at Source 133 Safety PSI 16.4 )X1l11 Pressure IAvailable Pressure of 149.8 psi Exceeds Required Pressure of 133.5 psi Summary This Is a safety margin of 16.4 psi or 11 X of Supply Advanced Summary I Max Density Available 0.159 GPM at Max Available Density 580 • Remote Area 5 Flowing Heads 15 Start Head PSI 127 Start Head GPM 80.0 SOFT per Head 130 Wet / Dry WET Hazard Ord. Grp. I Code NFPA 13 Construction Density 0.150 Area 933 Len/Wid Ratio 1.20 Max Velocity 26.3 Elev-Hd to Riser (') 240 PSI -Hd to Riser 8.66 Source Name or Location Source PSI Avail at Source 150 PSI Req'd at Source 133 Safety PSI 16.4 GPM Req'd at Source 547 (Inside Hose 0.000 Duration of Source 0.000 Outside Hose 250 Req'd Source Volume 0.000 Pressure IAvailable Pressure of 149.8 psi Exceeds Required Pressure of 133.5 psi Summary This Is a safety margin of 16.4 psi or 11 X of Supply Advanced Summary I Max Density Available 0.159 GPM at Max Available Density 580 • IPSI loss - TOR to Source 5.83 Rack Demand 0.000 ■ of ■ ■ '■ 4% .ES] (Inc ■ i 2 ' -OFFtCEI 411d7 0 ±,i Remote Area 5 Flowing Heads 15 Start Head PSI 127 Start Head GPM 80.0 SOFT per Head 130 Wet / Dry WET Hazard Ord. Grp. I Code NFPA 13 Construction Density 0.150 Area 933 Len/Wid Ratio 1.20 Max Velocity 26.3 Elev-Hd to Riser (') 240 PSI -Hd to Riser 8.66 Source Name or Location Source PSI Avail at Source 150 PSI Req'd at Source 133 Safety PSI 16.4 GPM Req'd at Source 547 (Inside Hose 0.000 Duration of Source 0.000 Outside Hose 250 Req'd Source Volume 0.000 Pressure IAvailable Pressure of 149.8 psi Exceeds Required Pressure of 133.5 psi Summary This Is a safety margin of 16.4 psi or 11 X of Supply Advanced Summary I Max Density Available 0.159 GPM at Max Available Density 580 • IPSI loss - TOR to Source 5.83 Rack Demand 0.000 MATCH LINE MATCH LINE 7 d 0 1kiiiiouv, • meman omitLffl, I i rekr. s IWell ' MIME 4 .cm)■t 14 1 114 " LI -1- 11 c3-91^, 2 Co 18' - 10 3/4" e ogramemesmnaummunneneessemusmsom e 0 0 12-11 00 MATCH LINE MATCH LINE FIST FLOO� 6-11 C. O 0 2 12-0 0 Ca) CJ `LL �-� \ -- r104 2 7-9 100B B 4.1 N R STOR. 153 114 J 9-812 114 5-10 0 114 0 114 B o o O 7114 3-5 .C. 114 I 114 8-8 o° `G 114 012-0 24) 302) 114 a 11 0 0 12-11 (625) 301) o z; 304) c' 114 623 303 1 13-3 WOM NS - 12' -0" 0 7-312 MENS 61 155 12'-0" 0 114 12-10 0 fi N � 11 12-0 `306, 114 ., 4-91 ©(B2 c1, 741 B1 114 14-0 14 6-19 12'-0" STORAGE 157 13. 9..r� 14 15-012 C 11 5- 4 I 0 O 114 13-31 O 77 1114 0 114 5-012 O 0 11 114 2-0 O /\ ITCHEN 151`x, 618 i@E 2< 114 10- 2-0 0- MATCH LINE MATCH LINE 114 5-012 L 0 114 114 -TING 114 /7 11\4\ Oft 8-6 MEI;CLO. 114 114 13-812 X12 vci 8- 11 4 - 114 12-0 -512 AWL DRAIN INSTPECTORS Tarr 1 LEGEND 1. 0 2. 3. 4. 5. 6. FLOW SWITCH 3" SUPERVISED BUTTERFLY VALVE PRESSURE GAUGE 3" CHECK VALVE 1 1 1/4" CHECKSSTVALVEAIN 2 1/2" CONNECTION TYPICAL COMRINATION STANDPIPE Remote Area 3 Flowing Heads 10 Start Head PSI 127 Start Head GPM 96.0 SOFT per Head 130 Wet / Dry WET Hazard Ord. Grp. I Code NFPA 13 Construction Density 0.150 Area 953 Len/Md Ratio 1.20 Max Velocity 18.0 Elev-Hd to Riser (') 240 PSI -Hd to Riser 8.66 Source Name or Location Source PSI Avail at Source 150 PSI Req'd at Source 129 Safety PSI 21.0 GPM Req'd at Source 453 Duration of Source 0.000 Req'd Source Volume 0.000 Inside Hose 0.000 Outside Hose 250 Pressure IAvalable Pressure of 149.9 psi Exceeds Required Pressure of 128.9 psi Summary This is a safety margin of 21.0 psi or 14 % of Supply Advanced Summary I Max Density Available 0.162 (PSI loss - TOR to Source 3.76 GPM at Max Available Density 488 Rack Demand 0.000 of 6z1� 26' 4% / \ (Inc `306, 114 ., 4-91 ©(B2 c1, 741 B1 114 14-0 14 6-19 12'-0" STORAGE 157 13. 9..r� 14 15-012 C 11 5- 4 I 0 O 114 13-31 O 77 1114 0 114 5-012 O 0 11 114 2-0 O /\ ITCHEN 151`x, 618 i@E 2< 114 10- 2-0 0- MATCH LINE MATCH LINE 114 5-012 L 0 114 114 -TING 114 /7 11\4\ Oft 8-6 MEI;CLO. 114 114 13-812 X12 vci 8- 11 4 - 114 12-0 -512 AWL DRAIN INSTPECTORS Tarr 1 LEGEND 1. 0 2. 3. 4. 5. 6. FLOW SWITCH 3" SUPERVISED BUTTERFLY VALVE PRESSURE GAUGE 3" CHECK VALVE 1 1 1/4" CHECKSSTVALVEAIN 2 1/2" CONNECTION TYPICAL COMRINATION STANDPIPE Remote Area 3 Flowing Heads 10 Start Head PSI 127 Start Head GPM 96.0 SOFT per Head 130 Wet / Dry WET Hazard Ord. Grp. I Code NFPA 13 Construction Density 0.150 Area 953 Len/Md Ratio 1.20 Max Velocity 18.0 Elev-Hd to Riser (') 240 PSI -Hd to Riser 8.66 Source Name or Location Source PSI Avail at Source 150 PSI Req'd at Source 129 Safety PSI 21.0 GPM Req'd at Source 453 Duration of Source 0.000 Req'd Source Volume 0.000 Inside Hose 0.000 Outside Hose 250 Pressure IAvalable Pressure of 149.9 psi Exceeds Required Pressure of 128.9 psi Summary This is a safety margin of 21.0 psi or 14 % of Supply Advanced Summary I Max Density Available 0.162 (PSI loss - TOR to Source 3.76 GPM at Max Available Density 488 Rack Demand 0.000 FOt. St)!(.,. ,yAvtAa h S.I.N VK462 VK458 HEAD NOTES VIKING VK462 5.6 1/2" 155' WHITE PENDENT CONCEALED VIKING VK458 7.4 3/4" 155' WHITE PENDENT SYM. o NO. 227 PIPING DESCRIPTION PENDENT ON CONCEALED PIPING CONCEALED WHITE ESC. REVISIONS DATE 0 20X20 0 540 PENDENT ON CONCEALED PIPING SEMI -RECESSED WHITE ESC. VK305 VIKING VK305 5.6 1/2" 155' WHITE SIDEWALL 75 SIDEWALL ON CONCEALED PIPING SEMI -RECESSED WHITE ESC. A VK460 VK302 VK302 VIKING VK460 5.8 1/2" 155' WHITE SIDEWALL 16x16 16x20 1/6dwn VIKING VK302 5.6 1/2" 155' WHITE PENDENT 138 SIDEWALL ON CONCEALED PIPING SEMI -RECESSED WHITE ESC. TOTAL FIRE PROTECTION INC. 1004 7TH AVE. NORTH P.O. BOX 680 BRANDON SD. 57005 (605) 582-240U e-mail: cbrandt@tfpsd.com DESIGN INSTALLER OWNER 86 PENDENT ON CONCEALED PIPING SEMI -RECESSED WHITE ESC. VIKING VK302 5.6 1/2" 155' WHITE PENDENT ENT COATING 0 22 PENDENT ON CONCEALED PIPING SEMI -RECESSED WHITE ESC. A T L ECTION 1004 7TH AVE. NORTH P.O. BOX 680 BRANDON3. 57005 (605) 582-2400 DESIGNER c u LIQ kECTION C. 1004 7TH AVE NORTH P.O. BOX 680 BRANDON SD. 57005 (605) 582-2400 Element By VTestin 515 Industry Drive Tukwila, WA 99188 ......... w w w w w w 1 /8"=12-4f1144600 Greg Lindholm Level III DRAWN BY: GREG LINDHOLM DATE 5-7-19 TOTAL A.S. 1088 SCALE: AS NOTED CHECKED BY: SHEET NO. 2of6 FIRE PREVENTION DIVISION MATCH LINE MATCH LINE 1 -BED STUDIO QQ STUDIO K STUDIO K II=�L�II STANDAR RD K 6-7' 10-10 3 10-10 114 H 114 114 12-0 STUDIO Q STUDIO QQ STUDIO K STUDIO K STUDIO K alAd �I®At 3,-9" STUDIO QQ COMMONS SUI r � TAN ARD i 241 .1 UDIO QQ ST STUD! 213 STUDIO STUDIO K = 10-11 co f SXA RD K WASHINGTON STATE CERTIFICATE OF COMPETENCY FIRE PROTECTION SPRINKLER SYSTEMS 1'4 10-11 MATCH LINE MATCH LINE SECO\I FLOO� xALEii8=1-0' N LEGEND 3 111:01111 - FLOW SWITCH 3" SUPERVISED BUTTERFLY VALVE PRESSURE GAUGE 3" CHECK VALVE 1 1/4" AGF TEST/DRAIN 1 1/4" CHECK VALVE 2 1/2" CONNECTION TYPICAL COMBINATIOn LATCH LINE LATCH LINE STAI\DPIPR 114 J MO, MEV 7' 7" 1 .._..�. �— MATCH LINE MATCH LINE K 114 1 4/ 114 RD K 114 114 9-1112 D 7,-7" 1'4 °D 9-0 114 2 7' 7" 5-10" rn 11-212 114 0=0._ I 11-0'2 1 -BED ADA TS I AUX. DRAN INEOPECTORB C) STAIR #1 ST -1 S.I.N HEAD NOTES VK462 VIKING VK462 5.6 1/2" 155' WHITE PENDENT CONCEALED SYM. 0 NO. 227 PIPING DESCRIPTION PENDENT ON CONCEALED PIPING CONCEALED WHITE ESC. REVISIONS DATE VK458 VIKING VK458 7.4 3/4" 155' WHITE PENDENT 20X20 • 540 PENDENT ON CONCEALED PIPING SEMI—RECESSED WHITE ESC. VK305 VIKING VK305 5.6 1/2" 155° WHITE SIDEWALL 75 SIDEWALL ON CONCEALED PIPING SEMI—RECESSED WHITE ESC. e TOTAL FIRE PROTECTION INC. 1004 7TH AVE. NORTH P.O. BOX 680 BRANDON SD. 57005 (605) 582-2400 e—mail: cbrandt@tfpsd.com VK460 VK302 VK302 VIKING VK460 5.8 1/2" 155° WHITE SIDEWALL 16x16 16x20 1/6dwn VIKING VK302 5.6 1/2" 155' WHITE PENDENT VIKING VK302 5.6 1/2" 155' WHITE PENDENT ENT COATING 0 138 86 22 SIDEWALL ON PENDENT ON PENDENT ON CONCEALED PIPING CONCEALED PIPING CONCEALED PIPING SEMI—RECESSED WHITE ESC. SEMI—RECESSED WHITE ESC. SEMI—RECESSED WHITE ESC. A A DESIGN INSTALLER OWNER L ECTION 1004 7TH AVE. NORTH P.O. BOX 680 BRANDON W. 57005 (605) 582-2400 DESKWE:I: G LINDHOLM TO AL ECTION 1004 7TH AVE. NORTH P.O. BOX 680 BRANDON SD. 57005 (605) 582-2400 INSTALLER Element 3y Westin 515 Industry Drive Tukwila, WA 99188 1 /8"=1'-0" 4CM alcholm 014Level III DRAWN BY: GREG LINDHOLM DATE 5-7-19 TOTAL A.S. 1088 SCALE: AS NOTED CHECKED BY: SHEET NO. 3 OF 6 FIRE PREVENTION DIVISION MATCH LINE MATCH LINE STUDIO QQ STUDIO K _ STUDIO K 1 336 r STA DAR DK 6—r: 10-10 5'-1 e" 114 114 114 12-0 10'-10" 3' 9" 3'-9" 10'-10" 4'-6" STUDIO Q STUDIO QQ STUDIO K STUDIO K :STUDIO K STANDARD K r 1-7' 7" TUDIO Q TS ADA 1' 4 10-11 o STUDIO O TUDIO K b STUDI -c.12 309 WA$H1N0TON STATE CERTIFICATE OF COMPETENCY FIRE PROTECTION SPRINKLER SYSTEMS TUDIO K STUDI K 1 P MATCH LINE MATCH LINE THRD FLOO zca.e 1/54-m C4 LEGEND 3 6 STUDIO QQ STANDA' FLOW SWITCH 3" SUPERVISED BUTTERFLY VALVE PRESSURE GAUGE 3" CHECK VALVE 1 1/ 4" CHECKSSTVALVEAIN --'----2 1/2" CONNECTION TYPICAL l COMBINATION STANDPIPE STUDIO QQ Ent S.I.N HEAD NOTES SYM. NO. PIPING DESCRIPTION REVISIONS DATE VK462 VIKING VK462 5.6 1/2" 155' WHITE PENDENT CONCEALED • 227 PENDENT ON CONCEALED PIPING CONCEALED WHITE ESC. VK458 VIKING VK458 7.4 3/4" 155' WHITE PENDENT 20X20 • 540 PENDENT ON CONCEALED PIPING SEMI -RECESSED WHITE ESC. VK305 VIKING VK305 5.6 1/2" 155' WHITE SIDEWALL 75 SIDEWALL ON CONCEALED PIPING SEMI -RECESSED WHITE ESC. TOTAL FIRE PROTECTION INC. 1004 7TH AVE. NORTH P.O. BOX 680 BRANDON SD. 57005 (605) 582-2400 e-mail: cbrandt@tfpsd.cam VK460 VIKING VK460 5.8 1/2" 155' WHITE SIDEWALL 16x16 16x20 1/6dwn 138 SIDEWALL ON CONCEALED PIPING SEMI -RECESSED WHITE ESC. VK302 VIKING VK302 5.6 1/2" 155' WHITE PENDENT 86 PENDENT ON CONCEALED PIPING SEMI -RECESSED WHITE ESC. A VK302 VIKING VK302 5.6 1/2" 155' WHITE PENDENT ENT COATING 0 22 PENDENT ON CONCEALED PIPING SEMI -RECESSED WHITE ESC. 48. A DESIGN1 TOTAL irg8TECTION INSTALLER OWNER MO4 77'H AVE. NORTH P.O. BOX 680 BRANDON SD. 57005 ( ) 582-2400 DEMMER c G LUNIEOLM rr'L ECTION 1004 7TH AVE NORTH P.O BOX 680 BRANDON SD. 57005 (605) 582-2400 84STALLER Element 3y YTestin 515 Industry Drive Tukwila, WA 99188 M N MM M M H ii K iii W M M Ki M 1 /8"=1'—" Greg Lkolm 1144600 Level III DRAWN BY: GREG LINDHOLM DATE 5-7-19 TOTAL A.S. 1088 SCALE: AS NOTED CHECKED BY: SHEET NO. 4OF6 FIRE PREVENTION DIVISION Remote Area 2 Flowing Heads 7 Start Head PSI 113 Start Head GPM 324 SQFT per Head 324 Wet / Dry WET Hazard Light Code NFPA 13 Construction Density 0.150 Area RM Design Len/Wld Ratio 1.20 Max Velocity 20.3 Elev—Hd to Riser (") 604 PSI —Hd to Riser 21.8 Source Name or Location Source PSI Avail at Source 150 Req'd at Source 438 Hose 0.000 (GPM (Inside PSi Req'd at Source 130 Duration of Source 0.000 Outside Hose 100 Safety PSI 19.7 Req'd Source Volume 0.000 Pressure Available Pressure of 149.9 psi Exceeds Required Pressure of 130.2 psi Summary This is a safety margin of 19.7 psl or 13 % of Supply Advanced Max Density Available 0.161 I PSI loss — TOR to Source 6.25 Summary GPM at Max Available Density 470 Rack Demand 0.000 MATCH LINE .MATC-1.1 LINE WASH' _ TON A CERTIFICATE OF COMPETENCY FIRE PROTECTION STUDIO K 0 STUDIO STUDIO K 536 STUDIO Q STANDARD K CORRIDOR STUDIO CLQ STUDIO STUD OQQ 510 8' 0" STUDIO 8' 0" STUDIO QQ UDOK 511_1 STUDIO K 50 STUDIO K A 1 TS ' S.I.N VK462 HEAD NOTES VIKING VK462 5.6 1/2" 155' STUDIO WHITE PENDENT CONCEALED SYM. NO. VK458 VIKING VK458 7.4 3/4" 155' WHITE PENDENT 20X20 0 • 227 L[ATerz 'Limn MATCH LINE FIFTH FLOO� xALE: o=r -0 MATCH LINE MATCH LINE Remote Area 1 Flowing Heads 7 Start Head PSI 113 Start Head GPM 204 SOFT per Head 204 Wet / Dry WET Hazara - ugnt Code NFPA 13 Construction Density 0.150 Area RM Design LenfMd Ratio 1.20 Max Velocity 22.9 Bev—Hd to Riser (') 714 PSI —Hd to Riser 25.8 Source Name or Location Source PSI Avail at Source 150 PSI Req'd at Source 106 Safety PSI 43.9 GPM Req'd at Source 347 'Inside Hose 0.000 Duration of Source 0.000 Outside Hose 100 Req'd Source Volume 0.000 Pressure Summary Available Pressure of 149.9 psi Exceeds Required Pressure of 106.0 psi This is a safety margin of 43.9 psi or 29 X of Supply Advanced Summary Max Density Available 0.178 IPS loss — TOR to Source 5.29 GPM at Max Available Density 412 Rack Demand 0.000 508 STAN DARD K = 8' 0 6 7' 1 -BED 6'-6" 504 REMOTE AREA 1 (105) REMOTE AREA 1 652 102 2 -BED 611 02 53'6_ 101 103 6'-3" (104 REMOTE AFPA 1 0 .r ' co co 0 44-1 0 1, TUDIO K 507 A STUDIO K 8'-0"— / 8' 0" D2 STANDARD K STANDARD K STUDIO QQ 1 -BED 503 8' 0" 7' 4" r., (602) 0 0 14441 108.7 0 107 WET > hiliTyNC 1W HOSE CABINET OUBLE HCGE /WNST ICY. ,/ v ACrtrr> COUPLI DRY ST' USE CNL x 1 -BED 501 ‘2t 6' 6" —7' 4" 1 MATCH LINE MATCH LINE Remote Area 6 Flowing Heads 3 Start Head PSI 100.0 Start Head GPM 250 SOFT per Head 250 Wet / Dry WET Hazard Standpipe Code NFPA 14 Construction Density 1.00 Area 750 Lend Ratio 1.20 Max Velocity 17.7 Elev—Hd to Riser (') 780 PSI —Hd to Riser 28.1 Source Name or Location Source PSI Avail at Source 150 PSI Req'd at Source 137 Safety PSI 12.7 GPM Req'd at Source 767 'Inside Hose 0.000 Duration of Source 0.000 Outside Hose 0.000 Req'd Source Volume 0.000 Pressure Summary Available Pressure of 149.7 psi Exceeds Required Pressure of 137.0 psi This is a safety margin of 12.7 psi or 8 X of Supply Advanced Summary Max Density Available 1.05 IPS! loss — TOR to Source —1.173 GPM at Max Available Density 801 Rack Demand 0.000 FREE—STANDING STANDPIPE PPE CEPART1+1ENT CONNECTION W/ PRESSURE COME • TOR STAIR #1 PN TO CONTROL ROOF ACCESS FREE—BTAND:40 FDC OOF ACCESS PIPING DESCRIPTION PENDENT ON CONCEALED PIPING CONCEALED WHITE ESC. REVISIONS DATE 540 PENDENT ON CONCEALED PIPING SEMI—RECESSED WHITE ESC. A VK305 VIKING VK305 5.6 1/2" 155' WHITE SIDEWALL 75 SIDEWALL ON CONCEALED PIPING SEMI—RECESSED WHITE ESC. e TOTAL FIRE PROTECTION INC. 1004 7TH AVE. NORTH P.O. BOX 680 BRANDON SD. 57005 (605) 582-2400 e—mail: cbrandt@tfpsd.com VK460, VK302\ VK302', VIKING VK460 5.8 1 /2" 155' WHITE SIDEWALL 16x16 16x20 1/6dwn VIKING VK302 5.6 1/2" 155' VIKING VK302 5.6 1/2" 155' WHITE PENDENT 138 SIDEWALL ON CONCEALED PIPING SEMI—RECESSED WHITE ESC. DESIGN INSTALLER OWNER 86 PENDENT ON CONCEALED PIPING SEMI—RECESSED WHITE ESC. A WHITE PENDENT ENT COATING • 22 PENDENT ON CONCEALED PIPING SEMI—RECESSED WHITE ESC. A A "LAL ECTION TOAAL rN?TECTION 1004 7TH AVE. NORTH P.O. BOX 680 1004 7TH AVE. NORTH P.O. BOX 680 BRANDON SD. 57005 (605) 582-2400 BRANDON SD. 57005 (605) 582-2400 DEQ GREG LINDHOLM INSTALLER= Element BY Westin 515 Industry Drive Tukwila, WA 99188 WI 64 *. s. W 4. 1 /8"=1'-0" Greg Unctholm Level III DRAWN BY: GREG LINDHOLM DATE 5-7-19 TOTAL A.S. 1088 SCALE: AS NOTED CHECKED BY: SHEET NO. 6 OF 6 FIRE PREVENTION DIVISION