Loading...
HomeMy WebLinkAboutPermit EL18-0135 - HOSTWINDS DATA - ADD 300 KVA TRANSFORER, 400A DISC, 4-200A PANELSHOSTWINDS DATA 3355 S 120 PL ELI 8-0135 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 1023049082 3355 S 120TH PL BLDG 5 Project Name: HOSTWINDS DATA ELECTRICAL PERMIT Permit Number: EL18-0135 Issue Date: 3/2/2018 Permit Expires On: 8/29/2018 Owner: Name: Address: Contact Person: Name: SABEY CORPORATION 12201 TUKWILA INTL BLVD 4TH FL , SEATTLE„ WA, 98168 BILL WYTHES Address: 6412 S 196TH ST, KENT, WA, 98032 Contractor: Name: E C COMPANY Address: PO BOX 10286 , PORTLAND, OR, 97296 License No: ECCOM**148BA Lender: Name: Address: !I/ Phone: (206) 375-3367 Phone: (503) 224-3511 Expiration Date: 6/30/2018 DESCRIPTION OF WORK: ADD 300 KVA TRANSFORER, 400A DISC, 4-200A PANELS Valuation of single family: $0.00 Valuation of mf/comm: $80,000.00 Type of Work: NEW Fees Collected: $1,865.94 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: 125 Sewer District: VALLEY VIEW Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Permit Center Authorized Signature: �A,�vla�r Ylii(�r✓1 Date: �8 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local la regulating construction or the performance of work. I am authorized to sign and obtain this development per it and a:ree to the conditions attached to this permit. Signature: Print Name: - 1 V This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***ELECTRICAL PERMIT CONDITIONS*** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC and the Washington Cities Electrical Code. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKWIL A Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov f Electrical Permit No. �vV1 Project No. Date Application Accepted: '1 ��// 1 Date Application Expires: et I 191 (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 92?,\c- '50V1-4-4: (2E t Tenant Name: i l 1 bS King Co Assessor's Tax No.: 7v1' L.04 '1,,(A1 Suite Number: "").-2-6 PROPERTY OWNER Name: 13 i cl w1/4//4145 Name: .569 [ (4 c.r.i- City: 1/..A. Address: lti1D� `rVY_tNtu1+, (N1L . (3U/0 City: State: tiiQ Zip: 9f L CONTACT PERSON — person receiving all project communication Name: 13 i cl w1/4//4145 Address: tc:„k-12 �'- --t, SI City: 1/..A. State: WA Zip: qcb yy Phone: r2 ,;(,7 3,13- 331x,7 Fax: Email: poi(,l . C� e7 C G PO PJ bt PE- ucivl Floor: New Tenant: 1 1 Yes ELECTRICAL CONTRACTOR INFORMATION Company Name: — (yam e/V`-'V Address: (e4(-2._ 5 lci L: -Ft. -4, 5..1. City:rv� State: (..„3,e, Zip: Phone: zac et_s ,, C.,,c, g Fax: Contr Reg No.:ct(4a4 f g- 31 Exp Date: Tukwila Business License No.; 605 `,) 9S3sit Valuation of Project (contractor's bid price): $ \© Scope of Work (please provide detailed information): "":CC) k -J t,L NsF0f 1)— 6) i Will service be altered? ❑ Yes No Adding more than 50 amps? Yes ❑ No Type of Use: Type of work: New 0 Addition 0 Service Change 0 Remodel Tenant Improvement ❑ Low Voltage ❑ Generator 0 Fire Alarm 0 Telecommunication 0 Temporary Service Property Served by: ❑ Puget Sound Energy Seattle City Light W:11'ernit Center Applications-Handouts\Pennit Applicatioos1Word'Electrical Permit Application Revised 1-1-2017.docx Revised: January 2017 bh Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $155.91 (including an attached garage) ❑ Garages, pools, spas and outbuildings $83.54 ea ❑ Low voltage systems (alarm, furnace thermostat) $61.05 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $83.54 (no added/altered circuits) ❑ Service change with added/altered circuits $83.54 number of added circuits $812.00 ea ❑ Circuits added/altered without service change $55.69 (up to 5 circuits) Circuits added/altered without service change $55.69 (6 or more circuits) $7.65 ea ❑ Meter/mast repair $69.62 ❑ Low voltage systems $61.05 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $66.30 ❑ Temporary service (generator) $82.52 ❑ Manufactured/mobile home service $87.98 (excluding garage or outbuilding) ❑ Carnivals $82.21 Number of concessions $11.02 ea Each ride and generator truck $11.02 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules, Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Date: "24 (3 I Print Name: i 1 „W),4 W T , S Day Telephone: -L',6 4-3k CJk' Mailing Address: 1-/-- S (Q.CM W:\Permit CenterlApplications-Handows\Pennit Applications \Word\Electrical Permit Application Revised 1.1-2017.docx Revised: January 2017 bh /bC WA /�(� > City Slate Zip Page 2 of 2 Register Recel City of Tukwila 1 DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY I ' PAID $1,865.94 EL18-0135 Address: 3355 S 120TH PL BLDG 5 Apn: 1023049082 $1,865.94 Credit Card Fee $54,35 Credit Card Fee R000.369,908.00.00 0.00 $54.35 ELECTRICAL $1,741.91 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $1,393.53 PLAN CHECK FEE R000.345.832.00.00 0.00 $348.38 TECHNOLOGY FEE $69.68 TECHNOLOGY FEE I TOTAL FEES PAID BY RECEIPT: R13775 R000.322.900.04.00 0.00 •-, .,. t $69.68 $1,865.94 Date Paid: Tuesday, February 13, 2018 Paid By: EC COMPANY Pay Method: CREDIT CARD 092581 Printed: Tuesday, February 13, 2018 10:27 AM 1 of 1 !SYSTEMS Z INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-36 Project:Type I S; (91(05 of Inspection: t �..� Address: Date Called: Special Instructions: klAdri�iP03Requester: Date Wanted: 3/07 4r5,n. Phone No: Approved per applicable codes. LJ Corrections required prior to approval. OM M ENTS: k,Q-cg`104_5 a Inspector: Date: Q3 fl7 fr REINSPECTION' FEE REQUIRED. Prior to next inspectio , fee ust be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36 Permit Inspection Request Line (206) 438-9350 Project: STL,J/ 1k 1. 0 Type of Inspection: c '4041 Address: . ?cc „.... ,}) --) • e.) /4-0 . Date Called: Special Instructions: Date Wanted: 7 a.m. Requester: Tb A & " it fri, ‘&14b . Phone No: 25-3 6-4 Approved per applicable codes. Corrections required prior to approval. COMMENTS: /ION' II 5e6 4,11)J111 T6 4& ffilk sf-E4)frib t-iiil iot,i140,vio(A/A) Tb A & " it fri, ‘&14b . 5f) A-C'C 11C- civ61.0 ro I D VbSiPt-T-1 Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. /, ?ERIC COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL18-0135 PROJECT NAME: HOSTWINDS DATA SITE ADDRESS: 3355 S 120TH PL X Original Plan Submittal Response to Correction Letter # DATE: 02/14/18 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Building Division Public Works C Fire Prevention Structural r Planning Division r Permit Coordinator LI PRELIMINARY REVIEW: Not Applicable ri (no approval/review required) DATE: 02/15/18 Structural Review Required REVIEWERc6 INITIALS: DATE: LI APPROVALS OR CORRECTIONS: DUE DATE: 03/15/18 Approved 111 Approved with Conditions El] Corrections Required n Denied E (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWERc6 INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials-. 12/18/2013 E C COMPANY Home Espanol Contact Safety & Health Claims & Insurance Washington State Department of Labor & Industries Search L&I Page 1 of 3 A -Z Index Help My L&1 Workplace Rights Trades & Licensing E C COMPANY Owner or tradesperson Principals ADAMS, GEORGE HARRY SCROGGY, JOEL J JANIK, STEPHEN THOMAS, VICE PRESIDENT BOCK, JAMES ARTHUR, VICE PRESIDENT BUSINESS FILINGS INCORPORATED, AGENT GOLDSTONE-SCHULLER, LEAH, MEMBER TRAPP, STEVEN C, MEMBER SCHMITZ, STEVEN D, MEMBER BALL, ROBERT SPENCER, MEMBER DESHLER, WILLIAM K (End: 06/28/2010) KELLY, RAYMOND THEODORE (End: 06/28/2010) PRENTICE-HALL CORP, AGENT (End: 06/28/2010) Doing business as E C COMPANY WA UBI No. 601 107 330 PO BOX 10286 PORTLAND, OR 97296 503-224-3511 Business type Corporation Governing persons WILLIAM K DESHLER ROBERT S BALL; STEPHEN T JANIK; MALERIN F HAWLEY; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active. Meets current requirements. License specialties GENERAL License no. ECCOM**148BA Effective — expiration 01/01/1986— 06/30/2018 Designated administrator BAKER, DON E Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601107330&LIC=ECCOM* * 148BA&SAW= 2/23/2018 PANEL P FMR LOCATION: SERVING: FED FROM: 480/277 VOLT 800 AMP MAIN LUGS ONLY 3 PHASE 4 WIRE MOUNTING: SURFACE DISCONNECT OCT LOAD DESCRIPTION TYPE KVA A/P PHASE NP KVA TYPE LOAD DESCRIPTION CKT 1 PANEL HW P1 - - P - - 60.240 -- - 200/3 - A 200/3 - - 60.000 - - P - - PANEL HW P3 2 3 B 4 5 C 6 7 PANEL HW P2 - - P - - 60.000 -- - 200/3 - A 200/3 - - 60.000 - - P - - PANEL HW P4 - 8 9 B 10 11 C 12 PHASE LOAD PHASE A= 88.00 KVA PHASE B= 80.06 KVA PHASE C= 72.18 KVA LOAD TYPE L R M H WH D A K LM TOTAL LOADS PANEL P-XFMR KVA AMP PANEL HW P1 0.06 0.18 60.00 60.24 KVA 72.46 AMP PANELHWP2 60.00 60.00 KVA 72.17 AMP PANEL HW P2 60.00 60.00 KVA 72.17 AMP PANEL HW P2 60.00 60.00 KVA 72.17 AMP CONN. LOAD 0.06 0.18 240.00 240.24 KVA 288.96 AMP CALC. LOAD 0.08 0.18 240.00 240.26 KVA 288.98 AMP NOTES: USED FOR PRIMARY SIDE TRANSFORMER LOAD CALCULATION ONLY. PANEL S-XFMR LOCATION: SERVING: FED FROM: 208/120 VOLT 800 AMP MAIN LUGS ONLY 3 PHASE 4 WIRE MOUNTING: SURFACE DISCONNECT CKT LOAD DESCRIPTION TYPE KVA A!P PHASE A!P KVA TYPE LOAD DESCRIPTION CKT 1 PANEL HW P1 - - P - - 60.240 - - 200/3 - - A 200/3 - - 60.000 - - P - - PANEL HW P3 2 3 B 4 5 C 6 7 PANEL HW P2 - - P - - 60.000 - - 200/3 - - A 200/3 - - 60.000 - - p - - PANEL HW P4 - 8 9 B 10 11 C 12 PHASE LOAD PHASE A= 88.00 KVA PHASE B= 80.06 KVA PHASE C= 72.18 KVA LOAD TYPE L R M H WH D A K LM TOTAL LOADS PANEL S-XFMR KVA AMP PANEL HW P1 0.06 0.18 60.00 60.24 KVA 167.21 AMP PANEL HW P2 60.00 60.00 KVA 166.54 AMP PANEL HW P2 60.00 60.00 KVA 166.54 AMP PANEL HW P2 60.00 60.00 KVA 166.54 AMP CONN. LOAD 0.06 0.18 240.00 240.24 KVA 666.84 AMP CALC. LOAD 0.08 0.18 240.00 240.26 KVA 666.88 AMP NOTES: USED FOR SECONDARY SIDE TRANSFORMER LOAD CALCULATION ONLY. (E)DISTRIBUTION SECTION_ r � BUS BAR (E)4 SETS '500KCMIL, 3/OG CU ' ii-E)Dlid (E)PULL BOX i ( 480/ I 277V I1200AFI © L - 1400AS (E)4 SETS 500KCMIL, 310G CU JUNCTION BOX 00 2 SETS (4)250KCMIL r AL, 1G AL ---J DISC 480/ 277V 400AF 400AS 1 GENERAL NOTES 1. PANELS HW P1 THROUGH HW P4 ARE WITHIN 10FT OF TRANSFORMER. PLAN NOTES O INTERCEPT EXISTING 1200A FEEDER. PROVIDE JUNCTION BOX WITH CONNECTOR BLOCKS AND TERMINATE EXISTING 1200A FEEDER. REMOVE ALL WIRE BEYOND NEW JUNCTION BOX LOCATION AND RETURN TO OWNER. PROVIDE ALL APPURTENANCES FOR COMPLETE OPERATION. O PROVIDE TERMINATION OF (2)SETS OF [(4)250KCMIL, (1)#1G] TO CONNECTOR BLOCK FOR NEW 400A FEEDER. O PROVIDE UNISTRUT RACK FOR NEW 400A FEEDER. O PROVIDE LEVITON VERIFEYE SERIES 2000 METER. PROVIDE ALL APPURTENANCES FOR COMPLETE OPERATION O REPLACE EXISTING 1200A FUSES WITH NEW 400A FUSES UNISTRUT RACK (4)250KCMIL AL, #4G AL o$C (2) LED STRIPS 9,396 AIC-/ J 2 SETS (3)250KCMIL AL, #1G AL HW P1 208/ 120V I FILE COPY Permit Ido. UIS' 1.)11 Plan review approval is subject to errors and omissions. Approval of construction documents doss not authorize the violation of ar, a . •pled code or ordinance. Roccipt of approved Field •p an jconns is acknowledged: 11, By: / Date: City of Tukwila BUILDING DIVISION 10/3 MC GABLE W/GROUID POWER DIST. STRIP TYP. OF 15 200A MCB (4)250KCMIL AL, #4G AL 9,392 AIC-/ HW P2 208/ 120V 200A MCB 0 10/3 MC CABL� W/GROUND POWER DIST. STRIP TYP. OF 15 (4)250KCMIL AL, #4G rAL -#1G AL 9,392 AIC-" (4)250KCMIL AL, #4G AL HW P3 208/ 120V 200A MCB 10/3 fv1C CABLE fl W/GIIIOUND 1 POWER DIST. 1 STRIP TYP. OF 15 I10/3 MC CABLE IJV/GROUND POWER DIST. I STRIP TYP. OF 15 9,396 AIC-/ HW P4 208/ 120V 200A MCB 0 TO PAD MOUNTED c) SCL TRANSFORMER EXISTING 1 ELECTRICAL ONE -LINE DIAGRAM E1.0 SCALE NONE RE/A ; ;1: i�hIschanical 0 iectr:cal umbing Gas Piping City of Tukwila B1.i `°.. , DIVISION rREVISIONS 1 No changes shall he made to the scope of work witho!it prior approval of NOTE: Revisions will rcquiro r;=..'r plan submlttai and may in zluda ad anal pian r .i r! f: E CITY OF TUKWIVED FEB REC13 2018ILA PERMIT CENTER 01 E 0 re'l"tA TRES WEST ENGINEERS TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com 2/12/18 PROJECT TITLE HOSTWINDS PROJECT ADDRESS 3355 S 120TH PLACE TUKWILA, WA 98168 1E1fIEWED FOR COMPLIANCE WITH NFPA70-NEC FEB 2 2 2018 pf2. City of Tukwila BUILDING DIVISIOk REVISION DATE CONSTRUCTION SET 2/12/18 ISSUED SHEET TITLE ELECTRICAL ONE -LINE DIAGRAM DRAWN CHECKED TWE JOB # CLIENT JOB # SHEET SCALE MLG MLG NONE SHEET NUMBER E1.0 r PANEL HW Pi LOCATION: SERVING: FED FROM: 208/120 VOLT 225 AMP BUS RATING SCCR: 10,000 A 3 PHASE 200 AMP MAIN BREAKER AFC: 9,396 A 4 WIRE MOUNTING: SURFACE SERVING: TRANSFORMER TRANSFORMER CKT LOAD DESCRIPTION TYPE KVA A/P PHASE NP KVA TYPE LOAD DESCRIPTION CKT 1 POWER DISTRIBUTION STRIP #1 - D - 4.000 - 30/2 A 30/2 - 4.000 - D - POWER DISTRIBUTION STRIP #9 - 2 3 - B 4 5 RACK MOUNTED PLUG STRIP #2 - D - 4.000 - 30/2 - C 30/2 - 4.000 - D - POWER DISTRIBUTION STRIP #10 - 6 7 A 8 9 RACK MOUNTED PLUG STRIP #3 - D - 4.000 - 30/2 - B 30/2 - 4.000 - D - POWER DISTRIBUTION STRIP #11 - 10 11 C 12 13 RACK MOUNTED PLUG STRIP #4 - D - 4.000 - 30/2 - A 30/2 - 4.000 - D - POWER DISTRIBUTION STRIP #12 - 14 15 B 16 17 RACK MOUNTED PLUG STRIP #5 - D - 4.000 - 30/2 - C 30/2 - 4.000 - D - POWER DISTRIBUTION STRIP #13 - 18 19 A 20 21 RACK MOUNTED PLUG STRIP #6 - D - 4.000 - 30/2 - B 30/2 - 4.000 - D - POWER DISTRIBUTION STRIP #14 - 22 23 C 24 25 RACK MOUNTED PLUG STRIP #7 - D - 4.000 - 30/2 - A 30/2 - 4.000 - D - POWER DISTRIBUTION STRIP #15 - 26 27 B 28 29 RACK MOUNTED PLUG STRIP #8 - D - 4.000 - 30/2 - C 20/1 0.180 R REC - MAINTENANCE 30 31 A - - S SPACE 32 33 LIGHTING L 0.060 20/1 B - - S SPACE 34 35 SPACE S - - C - - S SPACE 36 37 SPACE S - - A - - S SPACE 38 39 SPACE S - - B - - S SPACE 40 41 SPACE S - -C S - - S SPACE 42 S SPACE 42 PHASE LOAD PHASE A= PHASE LOAD PHASE A= 22.00 KVA PHASE B= 20.06 KVA PHASE C= 18.18 KVA KVA PHASE C= 18.00 KVA LOAD TYPE L R M H WH M D A K LM TOTAL LOADS CONN. LOAD 0.06 0.18 CONN. LOAD 60.00 60.00 60.00 60.00 60.24 KVA 167.21 AMP CALC. LOAD 0.08 0.18 CALC. LOAD 60.00 60.00 60.00 60.00 60.26 KVA 167.25 AMP 166.54 AMP NOTES: 166.54 AMP NOTES: PANEL HW P2 LOCATION: 208/120 VOLT 225 AMP BUS RATING SCCR: 10,000 A 3 PHASE 200 AMP MAIN BREAKER AFC: 9,392 A 4 WIRE MOUNTING: SURFACE SERVING: FED FROM: TRANSFORMER TRANSFORMER CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 POWER DISTRIBUTION STRIP #16 - D - 4.000 - 30/2 A 30/2 - 4.000 - D - POWER DISTRIBUTION STRIP #24 - 2 3 - B 4 5 RACK MOUNTED PLUG STRIP #17 - D - 4.000 - 30/2 C 30/2 - 4.000 - D - POWER DISTRIBUTION STRIP #25 - 6 7 - A 8 9 RACK MOUNTED PLUG STRIP #18 - D - 4.000 - 30/2 B 30/2 - 4.000 - D - POWER DISTRIBUTION STRIP #26 - 10 11 - C 12 13 RACK MOUNTED PLUG STRIP #19 - D - 4.000 - 30/2 A 30/2 - 4.000 - D - POWER DISTRIBUTION STRIP #27 - 14 15 - B 16 17 RACK MOUNTED PLUG STRIP #20 - D - 4.000 - 30/2 - C 30/2 - 4.000 - D - POWER DISTRIBUTION STRIP #28 - 18 19 A 20 21 RACK MOUNTED PLUG STRIP #21 - D - 4.000 - 30/2 - B 30/2 - 4.000 - D - POWER DISTRIBUTION STRIP #29 - 22 23 C 24 25 RACK MOUNTED PLUG STRIP #22 - D - 4.000 - 30/2 - A 30/2 - 4.000 - D - POWER DISTRIBUTION STRIP #30 - 26 27 B 28 29 RACK MOUNTED PLUG STRIP #23 - D - 4.000 - 30/2 - C - - S SPACE 30 31 A - - S SPACE 32 33 SPACE S - - B - - S SPACE 34 35 SPACE S - - C - - S SPACE 36 37 SPACE S - - A - - S SPACE 38 39 SPACE S - - B - - S SPACE 40 41 SPACE S - - C - - S SPACE 42 PHASE LOAD PHASE A= 22.00 PHASE LOAD PHASE A= 22.00 PHASE LOAD PHASE A= 22.00 KVA PHASE B= 20.00 KVA PHASE C= 18.00 KVA L LOAD TYPE L LOAD TYPE L R M H WH A D A K LM TOTAL LOADS CONN. LOAD 60.00 60.00 60.00 166.54 AMP 60.00 KVA 166.54 AMP 60.00 KVA 166.54 AMP CALC. LOAD 60.00 60.00 60.00 166.54 AMP 60.00 KVA 166.54 AMP 60.00 KVA 166.54 AMP NOTES: PANEL HW P3 LOCATION: 208/120 VOLT 225 AMP BUS RATING SCCR: 10,000 A 3 PHASE 200 AMP MAIN BREAKER AFC: 9,392 A 4 WIRE MOUNTING: SURFACE SERVING: FED FROM: TRANSFORMER CKT CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 POWER DISTRIBUTION STRIP #31 - D - 4.000 - 30/2 A 30/2 - 4.000 - D - POWER DISTRIBUTION STRIP #39 - 2 3 - B 4 5 RACK MOUNTED PLUG STRIP #32 - D - 4.000 - 30/2 - C 30/2 - 4.000 - D - POWER DISTRIBUTION STRIP #40 - 6 7 A 8 9 RACK MOUNTED PLUG STRIP #33 - D - 4.000 - 30/2 - B 30/2 - 4.000 - D - POWER DISTRIBUTION STRIP #41 - 10 11 C 12 13 RACK MOUNTED PLUG STRIP #34 - D - 4.000 - 30/2 - A 30/2 - 4.000 - D - POWER DISTRIBUTION STRIP #42 - 14 15 B 16 17 RACK MOUNTED PLUG STRIP #35 - 0 - 4.000 - 30/2 - C 30/2 - 4.000 - 0 - POWER DISTRIBUTION STRIP #43 - 18 19 A 20 21 RACK MOUNTED PLUG STRIP #36 - D - 4.000 - 30/2 - B 30/2 - 4.000 - D - POWER DISTRIBUTION STRIP #44 - 22 23 C 24 25 RACK MOUNTED PLUG STRIP #37 - D - 4.000 - 30/2 - A 30/2 - 4.000 - D - POWER DISTRIBUTION STRIP #45 - 26 27 B 28 29 RACK MOUNTED PLUG STRIP #38 - D - 4.000 - 30/2 - C - - S SPACE 30 31 A - - S SPACE 32 33 SPACE S - - B - - S SPACE 34 35 SPACE S - - C - - S SPACE 36 37 SPACE S - - A - - S SPACE 38 39 SPACE S - - B - - S SPACE 40 41 SPACE S - - C - - S SPACE 42 PHASE LOAD PHASE A= 22.00 PHASE LOAD PHASE A= 22.00 KVA PHASE B= 20.00 KVA PHASE C= 18.00 KVA LOAD TYPE L LOAD TYPE L R M H WH A D A K LM TOTAL LOADS CONN. LOAD 60.00 60.00 60.00 KVA 166.54 AMP 60.00 KVA 166.54 AMP CALC. LOAD 60.00 60.00 60.00 KVA 166.54 AMP 60.00 KVA 166.54 AMP NOTES: PANEL HW P4 LOCATION: SERVING: FED FROM: 208/120 VOLT 225 AMP BUS RATING SCCR: 10,000 A 3 PHASE 200 AMP MAIN BREAKER AFC: 9,396 A 4 WIRE MOUNTING: SURFACE TRANSFORMER CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 POWER DISTRIBUTION STRIP #46 - D - 4.000 - 30/2 - A 30/2 - 4.000 - D - POWER DISTRIBUTION STRIP #54 - 2 3 B 4 5 RACK MOUNTED PLUG STRIP #47 - D - 4.000 - 30/2 - C 30/2 - 4.000 - D - POWER DISTRIBUTION STRIP #55 - 6 7 A 8 9 RACK MOUNTED PLUG STRIP #48 - D - 4.000 - 30/2 - B 30/2 - 4.000 - D - POWER DISTRIBUTION STRIP #56 - 10 11 C 12 13 RACK MOUNTED PLUG STRIP #49 - 0 - 4.000 - 30/2 - A 30/2 - 4.000 - D - POWER DISTRIBUTION STRIP #57 - 14 15 B 16 17 RACK MOUNTED PLUG STRIP #50 - D - 4.000 - 30/2 - C 30/2 - 4.000 - D - POWER DISTRIBUTION STRIP #58 - 18 19 A 20 21 RACK MOUNTED PLUG STRIP #51 - D - 4.000 - 30/2 - B 30/2 - 4.000 - D - POWER DISTRIBUTION STRIP #59 - 22 23 C 24 25 RACK MOUNTED PLUG STRIP #52 - 0 - 4.000 - 30/2 - A 30/2 - 4.000 - D - POWER DISTRIBUTION STRIP #60 - 26 27 B 28 29 RACK MOUNTED PLUG STRIP #53 - D - 4.000 - 30/2 - C - - S SPACE 30 31 A - - S SPACE 32 33 SPACE S - - B - - S SPACE 34 35 SPACE S - - C - - S SPACE 36 37 SPACE S - - A - - S SPACE 38 39 SPACE S - - B - - S SPACE 40 41 SPACE S - - C - - S SPACE 42 PHASE LOAD PHASE A= 22.00 KVA PHASE B= 20.00 KVA PHASE C= 18.00 KVA LOAD TYPE L R M H WH 0 A K LM TOTAL LOADS CONN. LOAD 60.00 60.00 KVA 166.54 AMP CALC. LOAD 60.00 60.00 KVA 166.54 AMP NOTES: RECEIVED CITY OF TUKWILA FEB 132018 PERMIT CENTER TRES WEST ENGINEERS TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com 2/13/18 PROJECT TITLE HOSTWINDS PROJECT ADDRESS 3355 S 120TH PLACE TUKWILA, WA 98168 REVIEWED FOR COMPLIANCE WITH NFPA 70 m NEC FEB 2 2 2010 City of Tukwila BUILDING DIVISION.. REVISION DATE CONSTRUCTION SET 2/13/18 ISSUED SHEET TITLE ELECTRICAL PANEL SCHEDULES DRAWN MLG CHECKED MLG TWE JOB # CLIENT JOB # SHEET SCALE NONE SHEET NUMBER E2.0