Loading...
HomeMy WebLinkAboutPermit PG18-0097 - LEO STELLA - CIRCULATION PUMP, LAVATORY, SINK, SHOWER, DISHWASHER, WATER FILTER, ELECTRIC WATER HEATER ETCLEO STELLA 12501 E MARGINAL WAY S PGI 8-0097 Parcel No: Address: \ City of Tukwila ,� Deportment -^-_—_''-^--'--,.--- 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 VVebsite:http://www.TukwUaVVA'Rov PLUMBING/GAS PIPING PERMIT 7345600580 12501 E MARGINAL WAY S Project Name: LEO STELLA Permit Number: PG18-0097 Issue Date: Permit Expires On: 9/17/2018 3/16/2019 Owner: Name: INTERNATIONAL GATEWAY EAST Address: 122O1TUKVV|LA|NTRNTNLBL4TH , SEATTLE, WA, 98168 Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: KAYLENE NELSON 1ZZlSECOND AVE N,KENT, WA, 98032 HERMANSON COMPANY LLP (GENERAL) 1ZZI2ND AVE N'KENT, WA, 98032' 2945 HE0NA[0U0 ' Phone: (253) 359-7147 Phone: O06 575-9700 Expiration Date: 8/25/2020 DESCRIPTION OF WORK: PROVIDE AND INSTALL (I)CIRCULATION PUMP, (l)LAVATORY, (l) SINK, (Z)SHOWERS, (1)DISHWASHER, (l) COFFEEE MAKER, (1) INSTA-HOT, (1) WATER FILTER, (1) ELECTRIC WEATER HEATER, (1) EXPANSION TANK, (2) FLOOR DRAINS, (1) TRAP SEAL, (2) WALL CLEANOUTS AND (1) MIXING VALVE. Valuation of Work: $55,000.00 Water District: 125 Sewer District: VALLEY VIEW Fees Collected: $439.10 Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2015International Fuel Gas Code: 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 / Permit Center Authorized Signature: ri Date: I hearby certify that I have read and examined this permit and knovd'the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Date: oh -7116` Print Name r ( L J'P so \ This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 gauge. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27,170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 8004 GROUNDWORK 1900 PLUMBING FINAL 8005 ROUGH -IN PLUMBING I \ CITY OF TUKWL Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Plumbing/Gas Permit No. PG10- o Qom'( 7 Project No. Date Application Accepted: Date Application Expires: t--19-[ (For office use only) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION 1250\ King Co Assessor's Tax No.: 734560-0385 Site Address: O1 E Marginal Way S Suite Number: Floor: Tenant Name: Leo Stella PROPERTY OWNER Name: Kaylene Nelson Address: 1221 2nd Avenue N Name: Group Heath Phone: (253) 359-7147 Fax: Email: KAYLENE.NELSON@Hermanson.com Address: 3530 S 126TH ST City: Tukwila State: WA Zip: 98168 CONTACT PERSON — person receiving all project communication Name: Kaylene Nelson Address: 1221 2nd Avenue N City: Kent State: WA Zip: 98032 Phone: (253) 359-7147 Fax: Email: KAYLENE.NELSON@Hermanson.com New Tenant: 0 Yes ❑ .. No PLUMBING CONTRACTOR INFORMATION Company Name: Hermanson Company Address: 1221 2nd Avenue N City: Kent State: WA Zip: 98032 Phone: (253) 359-7147 Fax: Contr Reg No.:HERMAC005BJ Exp Date: 08/25/2018 Tukwila Business License No_: BUS0994464 Valuation of Project (contractor's bid price): $ 55,000 Scope of Work (please provide detailed information): Provide and install (1) Circ Pump, (1) Lav, (1) Sink, (2) Showers, (1) Dishwasher, (1) Coffee Maker, (1) Insta Hot, (1) Water Filter, (1) Electric Water Heater, (1) Expansion Tank, (2) Floor Drains, (1) Trap Seal, (2) Wall Cleanouts and (1) Mixing Valve. Building Use (per Int'l Building Code): 2015 Occupancy (per Int'l Building Code): Utility Purveyor: Water: H: Applications Forms -Applications On Line 2011 Applications Plumbing Permit Application Revised 8-9-1 l.docx Revised: August 2011 bh Sewer. Page 1 of 2 Indicate type of plumbing fixtures and/or `gas -piping outlets being installed and the quantity \. -,.low: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain 6 Shower, single head trap 2 Sinks 2 Rain water system — per drain (inside building) 3 Grease interceptor for commercial kitchen (>750 gallon capacity) Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Fixture Type Qty Bidet Drinking fountain or water cooler (per he) 6 Lavatory Urinal Water heater and/or vent 3 Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atnnospheric- type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial 6 Wash fountain Water closet Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets Fixture Type Qty Dental unit, cuspidor Floor drain 6 Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of tirne for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 Signature: UTHORIZED AGENT: Print Name: Kaylene Nelson Mailing Address: 1221 2nd Avenue N H: Applications Forms -Applications On Line 2011 Applications Plumbing Permit Application Revised 8-9-11.docx Revised: August 2011 bh Date: Day Telephone: (253) 359-7147 Kent WA 98032 City State Zip Page 2 of 2 DESCRIPTIONS ACCOUNT PermitTRAK PG18-0097 Address: 12501 E MARGINAL WAY 5 Apn: 7345600580 Credit Card Fee Credit Card Fee PLUMBING ADDITIONAL PLAN REVIEW TOTAL. FEES PAID BY RECEIPT: R QUANTITY PAID 6158 R000.369.908.00.00 R000.345.830.00.00 0.00 1.00 $68.83 $68.83 $2.00 $2.00 $66.83 $66.83 $68.83 Date Paid: Tuesday, December 18, 2018 Paid By: KAYLENE NELSON Pay Method: CREDIT CARD 586744 Printed: Tuesday, December 18, 2018 9:50 AM 1 of 1 4 Ii I SYSTEMS DESCRIPTIONS ACCOUNT QUANTITY 1 PAID PermitTRAK $354.66 PG18-0097 Address: 12501 E MARGINAL WAY S Apn: 7345600580 $354.66 Credit Card Fee $10.33 Credit Card Fee R000.369.908.00.00 0.00 $10.33 PLUMBING $327.93 PERMIT FEE R000.322.100.00.00 0.00 $294.78 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 TECHNOLOGY FEE $16.40 TECHNOLOGY FEE R000.322.900.04.00 0.00 $16.40 TOTAL FEES PAID BY RECEIPT: R 5411 $354.66 Date Paid: Monday, September 17, 2018 Paid By: KAYLENE NELSON Pay Method: CREDIT CARD 155893 Printed: Monday, September 17, 2018 12:24 PM 1 of 1 YSTEMS DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK $717.66 M18-0094 Address: 12501 E MARGINAL WAY S Apn: 7345600580 $633.22 Credit Card Fee $18.44 Credit Card Fee R000.369.908.00.00 0.00 $18.44 MECHANICAL $614.78 PLAN CHECK FEE R000.322.102.00.00 0.00 $614.78 PG18-0097 Address: 12501 E MARGINAL WAY S Apn: 7345600580 $84.44 Credit Card Fee $2.46 Credit Card Fee R000.369.908.00.00 0.00 $2.46 PLUMBING $81.98 PLAN CHECK FEE 4982 R000.322.103.00.00 0.00 $81.98 $717.66 TOTAL FEES PAID BY RECEIPT: R Date Paid: Thursday, July 19, 2018 Paid By: SYDNEY LOWERY Pay Method: CREDIT CARD 541823 Printed: Thursday, July 19, 2018 10:40 AM 1 of 1 SYSTEMS Page 1 of 2 CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA 0017340000802374464500 Date: 12/18/2018 09:50:29 AM CREDIT CARD SALE VISA CARD NUMBER: **********0057 K TRAN AMOUNT: $68.83 APPROVAL CD: 586744 RECORD #: 000 CLERK ID: Rachelle X {CARDHOLDER'S SIGNATURE} I AGREE TO PAY THE ABOVE TOTAL AMOUNT ACCORDING TO THE CARD ISSUER AGREEMENT (MERCHANT AGREEMENT IF CREDIT VOUCHER) Thank you! Merchant Copy https://classic.convergepay.com/VirtualMerchant/transaction.do?dispatchMethod=printTr... 12/18/2018 / CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA Date: 12/18/2018 09:50:29 AM CREDIT CARD SALE VISA CARD NUMBER: **********0057 K TRAN AMOUNT: $68.83 APPROVAL CD: 586744 RECORD #: 000 CLERK ID: Rachelle Thank you! Customer Copy Page 2 of 2 https://classic. convergepay.com/V irtualMerchant/transaction.do?dispatchMethod=printTr... 12/18/2018 Page 2 of 2 CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA Date: 09/17/2018 12:23:50 PM CREDIT CARD SALE VISA CARD NUMBER: **********0057 K TRAN AMOUNT: $354.66 APPROVAL CD: 155893 RECORD #: 000 CLERK ID: Rachelle Thank you! Customer Copy https://classic.convergepay.com/Virt:ualMerchant/transaction.do?dispatchMethod=printTra... 9/17/2018 / CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA 0017340000802374464500 Date: 09/17/2018 12:23:50 PM CREDIT CARD SALE VISA CARD NUMBER: **********0057 K TRAN AMOUNT: $354.66 APPROVAL CD: 155893 RECORD #: 000 CLERK ID: Rachelle X (CARDHOLDER'S SIGNATURE} I AGREE TO PAY THE ABOVE TOTAL AMOUNT ACCORDING TO THE CARD ISSUER AGREEMENT (MERCHANT AGREEMENT IF CREDIT VOUCHER) Thank you! Merchant Copy Page 1 of 2 https://classic.convergepay.comNirtualMerehant/transaction.do?dispatchMethod=printTra... 9/17/2018 f CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA 0017340000802374464500 Date: 07/19/2018 10:39:54 AM CREDIT CARD SALE VISA CARD NUMBER: **********4691 K TRAN AMOUNT: $717.66 APPROVAL CD: 541823 RECORD #: 000 CLERK ID: Bill X {CARDHOLDER'S SIGNATURE} I AGREE TO PAY THE ABOVE TOTAL AMOUNT ACCORDING TO THE CARD ISSUER AGREEMENT (MERCHANT AGREEMENT IF CREDIT VOUCHER) Thank you! Merchant Copy Page 1 of 2 https: //classic. convergepay. com/V irtualMerchant/transaction. do?dispatchMethod=printTra... 7/19/2018 INSPECTION RECORD Retain a copy with permit P4ie 617 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project: FO at-catilt Type of Inspection: Q../ rri (3 0.1d Date:, Address: IZ5°1 6 IiikACIA-alt- ti.44/ Date Date Called: ate Wanted: Special Instructions: 130 pm. p.m. Requester: Xid Phone No: Z€&57/ 7,e3o Approved per applicable codes. Corrections required prior to approval. COMMENTS: 9(-g70 Inspector: 0l 171_ a . Date:, REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF 'TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: I-ro ofet4A Type of Inspection: p4/47004 Date Called: --4 • 76'44C''' Address: '2- irol t— Arl if ',, Special Instructions: 'ate Wanted: /-16, tei P rrl• Requester: Phone No: LJApproved per applicable codes. orrections required prior to approval. ALee Pto L J LA) S AGO ,Y1 • _...tiv11-- 0213 lnsp REINSPECTION FEE REGIUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit faidit6 PERMIT NO. 97 CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pro ec : Type of Inspection: • ; Address: /257.; itif I- it, Special ns uc ons: i.r PrZ Date W. • ed: — . a. p- • Requester: Phone No: le-K- aw Approved per applicable codes. Corrections required prior to approval. COMMENTS: v 0 AZ. , Ae=ke_d 0 dre errktod IAAViev. /1.1244-jee- le-K- aw P spill( a., M -r 4 /7°,4- hot- cvi rtii,6 a4S'ein b 1 .-7-..-/- R + r /ono (61 kilk! t_61c.5. REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter E3lvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: LZO 6 -M -1-i-4 Type of Inspection: 76ogifJ1-, T -i -A9 4 Address: 12-5,01 a MAR./dom._ S Date Called: Special Instructions: Date Wanted: il - Ili- Lot a . •.m. Requester: Phone No: ElApproved per applicable codes. COMMENTS: .7, Nt* r 14, oval. n pet or: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit P�1'-0% INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Leo sreLCJ1- Type of Inspection: Address: /23-P/ £,/rd 4Yr¢c. /ay Date Called: Special Instructions: /ZaJ6 k -IN PLO 111 6/116-/ Date Wanted:3130 7-/� _ p.m. Requester: Phone No: Approved per applicable codes. L Corrections required prior to approval. COMMENTS: pe avials/N&�-- Foy 4- 1n( ,Q/43 // / C-1) /LCA i elft nspector: res Date: /6 -/ 7-h9 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 41) INSPECTION NO. INSPECTION RECORD im Retain a copy with permit "N-007 PERMIT NO. CITY OF: TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Leo STeLIA4 T e of Inspection: Q_ /111 al4nArj y12 , N. Address: 1 250 1 . Special n u ion : Date ailed: cr Date Wanted:a.m. /0 -4s-- zair p.m. Reque5Ier, Izi ///1 Phone No: ZO — 552 33W — / 2L. - Approved per applicable codes. Corrections required prior to approval. •NT5 N. iiifiN 1/04(2., Izi ///1 ki A:: — / 2L. - -,,,,, -=—• '—'. , Ntjammerm. Inspector: 9 ate: 0 15-- REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. C9 INSPECTION RECORD Retain a copy with permit INSPECTION NO, PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Projec-.. Lo 1 A li_rt E Type of Inspection: G ro.....r.rie o rtc .1 ii Address: / 230 E.. ftl4 Special Instructions: ... an e.. /0- 6 - 2-0 a. . p• • Req ter: /- Phone No: Z or° -552 33 2- 0 Approved per applicable codes. Corrections required prior to approval. COMMENTS: te 110(A)e4r_i/ nspector: Date:/o REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection, W1 LIU/ ( n I))ADJUST NG & BALANCI\G CERTIFIED REPORT RECEIVED CITY OF TUKWILA Leo Stella TI — Air Balance Report APR 16 2019 »I'Iernianson 12501, Suite # 1B — Phase #2 PERMIT CENTER Project Name: Address: Leo Stella TI 12501 East Marginal Way South Suite # 1B Tukwila, WA 98168 Design Engineer: Hermanson Company LLP Hermanson Number: 21-18-13166 This is to certify that Hermanson Company, LLP has Tested, Adjusted, and Balanced the systems described herein to their best possible performance capabilities. Data presented is a record of measurements and adjustments at the time the work was performed. This test and the associated balancing was performed in accordance with the TABB Procedural Guide (2003) and other industry standards. This work is warrantied for and expires ninety days from the report date unless otherwise stated in contract documents specific to this project. Submitted and certified by: Kevin R. Gibson, TABB and IAQ Technician Date: 04/15/2019 Certir/cat/ '83 ANSI Kevin Gibson TABB Technician B810 -73893T June 30, 2020 Probed. or.rvmre /Tied Tecr / I. /41143 Kevin Gibson indoor Air Quality Technician 1AQ1073893T June 30, 2020 Printed. envie.e TESTING ADJUSTING AND BALANCING BUREAU THE PROFESSIONAL'S CHOICE" »Hermanson 1221 2nd Avenue North, Kent WA 98032 Tel: 206 575-9700 Fax: 206.575.9800 I HERMANSON COM REPORT SUMMARY 1) General Information a) This report is based on actual field readings taken during operation unless otherwise noted. Work for Phase #1 was completed on: 04/15/19 b) Equipment is inspected for proper and safe operation unless noted in this summary or the associated data contain herein. c) Work requiring adjustments will be performed to +/-10% of the design value unless other specifications require increased/decreased tolerances and approval by the Engineer of Record (EOR) or Authority Having Jurisdiction (AHJ). Flow rates were measured with calibrated instruments and are listed on the tool summary. d) All suggestions to further improve performance or function need to be fully vetted and verified by all interested parties (i.e. Engineer, Owner, Tenant, Contractor) e) Deficiencies noted throughout this report are the responsibility of the parties having an interest in them and are not to be corrected by the TAB team unless instructed in the contract documents. Notes are added for clarification as applicable. f) Design information is drawn from various sources to include, but not limited to: Drawings, specifications, user manuals, shop drawings, submittals, service history, legacy documents, and oral & photographic information. Additionally, unspecified values may be field determined as required in the absence of engineered values, based on current best practices. 2) Scope of the Project (Overview) a) Inspection of the newly installed equipment: (25) VAV Units, (4) Supply Air Fans, (5) Humidifiers, (1) Package HP with Power Exhaust, (1) Fan Coil Unit/HP, and Distech Controls System for proper installation and safe operation. b) Verify airflows and offer suggestions as required. c) Correct any deficiencies if possible; Repaired VAV Unit's Factory Wiring. d) Provide the owner with a certified Final TAB report, demonstrating the actual airflow. 3) System Description a) 1- Ground Mounted Packaged Heat Pump with Duct Mounted Power Exhaust b) 25- FP VAV Boxes c) 6- Humidifiers d) 1- Exhaust Fans e) 4- Supply Fans f) 1- Heat Pump / Fan Coil Unit 33Herrnanson 1221 2nd Avenue North h f1 NA 9802 Tel 21:6 175 N 21:6.5 REPORT SUMMARY 4) Findings: a) Equipment Not Installed, from Schedule: FP -1B-50, EF -1B-09, EF -1B-10. (Omitted from original contract) b) VAV Unit # FP -1B-05: (Serves Clean Room) Supply Air is at 65% of Design, Restriction from supply air 99.97% HEPA filter. (Plans in progress to replace HEPA filters with high flow filtration by Hermanson Service, after construction is completed.) c) VAV Unit # FP -1B-28: (Serves Clean Room) Supply Air is at 81% of Design, Restriction from supply air 99.97% HEPA, causing supply air to blow out the return air filter opening. (Plans in progress to replace HEPA filters with high flow filtration by Hermanson Service, after construction is completed.) d) VAV Unit: # FP -1B-33: (Serves Open Office — Central Space) Outlet #4 was removed from mechanical prints original location in system, Adjusted overall Supply CFM. e) VAV Unit: # FP -1B-39: (Serves Open Office — Central Space and West Phone Rooms) Outlet #3 and #4 was removed from system's original print location, A new Supply Diffuser with a higher CFM was installed for the new CD -3 with a new design of 165 CFM, Adjusted overall Supply CFM to fan motor/electrical element manufacturers minimum. f) FCU -1B-101: (Serves Bake Out Room) Supply Air has a new Design of 1320 CFM. Quantity of Bake Out Oven Cooling Capacity has changed for the room. Fan Motor set to new Static Pressure setpoint of setting 09 from 15. ))Hermanson rd5F:.! REPORT SUMMARY Thank you for the choosing the Hermanson Company, it has been my pleasure to work with you and your team. Please let me know of any questions. Thank you, Kevin Kevi,vt/ Gi.bsow Kevin Gibson I TABB / Controls / IAQ / FLS / Service - Technician Fire Life Safety, Fire / Smoke - Supervisor Hermanson Company, LLP 1 21440 68th Ave S, Kent, WA 98032 Office 206-575-9700 1 Cell 206-552-4178 www.hermanson.com Siounwinsom ivi r n "1 9 2 75 7 !l' r •�D *Hermanson 1221 Znv,ti.c�,7i.i.. t��:rih, Ken' �,rr . ��I32 Tel cl+: ��� •_ �+� )i) =:�x 11�,_ � _ �?�t��;�� F�E�?�.��f��S,�N �_,�Jh., Dilermanson 1221 2nd Avenue North, Kent WA 98032 Main Tel: 206-575-9700 Fax: 206-575-9800 http://hermanson.com/ AC or ACU Air Conditioning Unit EAT Entering Air Temperature LIP Pressure Drop. AHU Air Handling Unit EF Exhaust Fan PH Phase Ak The area of an opening in sq./ft. EG/ED Exhaust Grille/Diffuser PSI Pounds per Square Inch ATM Atmosphere EMS Energy Management System RA Return Air AVG Average ERU Energy Recovery Unit RAT Return Air Temperature BHP Brake Horsepower FHT Fume Hood Test RF Return Fan CAV Constant Air Volume FPB Fan Powered Box RH Relative Humidity CBV Cal. Balance Valve FPM Feet per Minute RHC Reheat Coil CC Cooling Coil FT Foot, Feet RPM Revolutions per Minute CD Ceiling Diffuser GPM Gallons per Minute RTU Roof Top Unit CFM Cubic Feet per Minute HC Heating Coil SA Supply Air CH Chiller TDH — Total Dynamic Head - Pump SAT Supply Air Temperature CHWS Chilled Water Supply HEPA High Efficiency Particulate Arrestance S.F. Service Factor CHWR Chilled Water Return HP Horsepower SF Smoke/Fire Damper CP Circulating Pump HVAC Heating Ventilation and AC SWG Sidewall Grille CD/CR Ceiling Diffuser/Register HWS Heating Water Supply TAB Test, Adjust & Balance CRAC Computer Room AC HWR Heating Water Return TEMP Temperature CRU Computer Room Unit HX Heat Exchanger TON 12,000 BTUH (Cooling CT Cooling Tower HZ Hertz, cycle/second of current TSTAT Thermostat (T) CU Condenser Unit in.w.g. inches of water gauge TSP Total Static Pressure CUH Cabinet Unit Heater K-factor Correction factor to the free area needed t o calculate CFM UH Unit Heater CWS Condenser Water Supply KW Kilowatts V Volt — Either AC or DC CWR Condenser Water Return LAT Leaving Air Temperature VAV Variable Air Volume box D Discharge LWT Leaving Water Temperature VD Volume Damper DAT Discharge Air Temperature MAU Make-up Air Handling Unit VEL Velocity (usually in FPM) DB Dry Bulb MBH 1,000 BTUH VFD Variable Frequency Drive DDC Direct Digital Controls NT Not Tested VVT Variable Volume Terminal DP Differential Pressure OSA Outside Air W.G. Water Gauge DNA Data not available or given OBD Opposed Blade Damper WB Wet Bulb DNV Data Not Visible OD Outside Diameter 1) TAB — Test the quantitative performance according to the design 2) Flowhood — Instrument used by 3) Total Static Pressure - Difference 4) Economizer — Components and controls cooling to save energy and provide 5) Total Dynamic Head - The difference 6) Design Tolerance — Specified by the 7) Ratio of Tolerance - Used to verify of design if design was 250 then of a system then regulate it to a specific rate and to the proportion the flow a Balancer to capture air and measures and reports in CFM in pressure from the inlet to the discharge of a fan added together that allow an air handler to effectively use outside air instead of mechanical building pressurization between the pressure of a fluid entering a pump vs exiting added together designer or +/-10% that terminals and/or the system are within Design Tolerance; Example 90%-110% .90/1.10=1.22 and flow between 275CFM-22SCFM would be acceptable w a $ DEP:ER It' FIRED o RESULTS .« AND IIMANAIN IIINIAU »K.Ywr- Mermanson Air Handling Unit PROJECT: LEO STELLA TI LOCATION: Tukwila, WA PROJECT #: 21-18-13166 DATE: 4/15/2019 CONTACT: Kevin Gibson AUTHOR: Kevin Gibson WE BUILD Tg..,.iv: , F,s, 4!:1:,44.., RESULTS SYSTEM/UNIT: AHU-Existing Unit Data Unit Manufacturer Trane -105 Ton Air Cooled Unit Model Number SXHGD1140R86CE7D800100 0000KLONRT0000 Unit Serial Number C00J27357 Unit Discharge Downbiast Test Data Design Airflow 31000-46000 CFM L/S Log: Tested By: Kevin Gibson Date: 12/10/2018 AHU-Existing 12/11/2018 Kevin Gibson AHU East, Distech Address: 32 SYSTEM/UNIT: AHU-Existing/FP-1B-03 Tested By: Kevin Gibson Date: 4/15/2019 AREA: 1st Floor Unit Data Manufacturer Model Number Serial Number VAV Address Box Inlet Size K Factor Remark Krueger KQFS-3-8 18-733456-C-001 4 8 920.000 Building Entry AHU-Existing/FP-1 B-03 Supply Outlet Summary Term Box Test Data VAV Fan Design VAV Fan Actual Design Max Airflow Design Min Airflow 600 CFM L/S 660 CFM L/S 600 CFM LIS 125 CFM LIS System/Unit Area Served Outlet Type Size LxW ! D Design Airflow Prelim Airflow % Prelim Diff. Final Airflow % Final Diff. Remark Outlet -01 North Lobby North Lobby RD3 Round 10 300 160 53 330 110 key Outlet -02 North Lobby North Lobby RD3 Round 10 300 370 123 330 110 50% closed Totals: - - 600 0 530 0 88 0 660 0 110 0 - Hermanson }Hermanson Air Handling Unit PROJECT: LEO STELLA TI LOCATION: Tukwila, WA PROJECT #: 21-18-13166 i., 1V1P.001140.0•11.1101110161414110 OM. 8 .11 .110000111401411111011•11" DATE: 4/15/2019 CONTACT: Kevin Gibson AUTHOR: Kevin Gibson WE BUILD Fa LIIYAS4,FS g MUM Pt ,StiNLO RESULTS SYSTEM/UNIT: AHU-Existing/FP-1B-04 AREA: lst Floor Unit Data Manufacturer Model Number Serial Number VAV Address Box Inlet Size K Factor Remark Krueger KQFS-3-10 18-733456-C-002 5 10 1480.000 Incoming&Sub-Assembly AHU-Existing/FP-1B-04 Supply Outlet Summary Tested By: Kevin Gibson Date: 4/15/2019 Term Box Test Data VAV Fan Design VAV Fan Actual Design Max Airflow Design Min Airflow 730 CFM L/S 730 CFM US 730 CFM us 230 CFM US System/Unit Area Served Outlet Type Size LxW / D Design Airflow Pirelim Airflow % Prelim Diff. Final Airflow % Final Diff. Remark Outlet -01 Sub -Assembly Sub -Assembly DT3-Titus MCD 10/10 250 250 100 250 100 closed 10% Outlet -02 Sub -Assembly Sub -Assembly DT3-Titus MCD 10/10 240 220 92 230 96 key Outlet -03 Sub -Assembly Sub -Assembly DT3-Titus MCD 10/10 240 230 96 250 104 key Totals: - - 730 0 700 0 96 0 730 0 100 0 - SYSTEM/UNIT: AHU-Existing/FP-1B-05 AREA: 1st Floor Unit Data Manufacturer Model Number Serial Number VAV Address Box Inlet Size K Factor Remark Krueger KQFS 3-10 18-733456-C-005 6 10 1474.000 Clean Room(N.Ext) F: 1©16.5/19" AHU-Existing/FP-1B-05 Supply Outlet Summary Tested By: Kevin Gibson Date: 4/15/2019 Term Box Test Data VAV Fan Design VAV Fan Actual Design Max Airflow Design Min Airflow 840 CFM L/S 550 CFM US 840 CFM L/S 250 CFM L/S System/Unit Area Served Outlet Type Size LxW / D Design Airflow Prelim Airflow % Prelim Diff. Final Airflow % Final Diff. Remark Outlet -01 Clean Room Clean Room DT3-Titus MCD 10/10 280 170 61 180 64 Outlet -02 Clean Room Clean Room DT3- Titus MCD 10/10 280 220 79 190 68 20% closed Outlet -03 Clean Room Clean Room DT3- Titus MCD 10/10 280 160 57 180 64 key Totals: - - 840 0 550 0 65 0 550 0 65 0 - Hermanson )Hermanson Air Handling Unit PROJECT: LEO STELLA TI LOCATION: Tukwila, WA PROJECT #: 21-18-13166 DATE: 4/15/2019 CONTACT: Kevin Gibson AUTHOR: Kevin Gibson WE BUILD LMVP NIARL0 RESULTS SYSTEM/UNIT: AHU-Existing/FP-1B-07 AREA: 1st Floor Unit Data Manufacturer Krueger Model Number KQFS-3-12 Serial Number 18-733456-C-004 VAV Address 7 Box Inlet Size 12 K Factor 2487.000 Remark Cafeteria (E. EXT.) New Fan Speed •100% Log: Tested By: Kevin Gibson Date: 4/15/2019 Term Box Test Data VAV Fan Design VAV Fan Actual Design Max Airflow Design Min Airflow 1065 CFM US 1080 CFM US 1065 CFM US 320 CFM US AHU-Existing/FP-1 B-07 AHU-Existing/FP-1 B-07 12/7/2018 Kevin Gibson 12/7/2018 Kevin Gibson FP -1B-07 : Cafeteria area Schedule omitted supply outlet in hallway New minimum supply air FP -1B-07: Cafeteria area Schedule omitted CFM for hallway supply outlet of 180 CFM New supply air maximum AHU-Existing/FP-1 B-07 Supply Outlet Summary System/Unit Area Served Outlet Type Size LxW / D Design Airflow Prelim Airflow % Prelim Diff. Final Airflow % Final Diff. Remark Outlet -01 Cafeteria Cafeteria DT1-Titus MCD 10/10 180 110 61 180 100 key Outlet -02 Cafeteria Cafeteria DT3-Titus MCD 10/10 295 200 68 295 100 Outlet -03 Cafeteria Cafeteria DT3-Titus MCD 10/10 295 210 71 305 103 closed 10% Outlet -04 Cafeteria Cafeteria DT3-Titus MCD 10/10 295 210 71 300 102 closed 15% Totals: - - 1065 0 730 0 69 0 1080 0 101 0 - Hermanson hiermanson Air Handling Unit PROJECT: LEO STELLA TI LOCATION: Tukwila, WA PROJECT #: 21-18-13166 I A'S 7:- .111~4.0.4MOMNIMINWIA011eall. B Ms fulDlimmoilklb Yam, DATE: 4/15/2019 CONTACT: Kevin Gibson AUTHOR: Kevin Gibson WE BUILD l';'.51 FILAirNS + Ft; 8 OfirYffi: ikt.St'iRLO RESULTS SYSTEM/UNIT: AHU-Existing/FP-1B-08 AREA: 1st Floor Unit Data Manufacturer Model Number Serial Number VAV Address Box Inlet Size K Factor Remark Krueger KQFS-3-14 18-733456-C-005 8 14 2511.000 Open Office(S.Ext.) New Fan Speed 38% AHU-Existing/FP-1B-08 Supply Outlet Summary Tested By: Kevin Gibson Date: 4/15/2019 Term Box Test Data VAV Fan Design VAV Fan Actual Design Max Airflow Design Min Airflow 940 CFM L/S 1000 CFM US 940 CFM US 390 CFM US System/Unit Area Served Outlet Type Size LxW / D Design Airflow Prelim Airflow % Prelim Diff. Final Airflow % Final Diff. Remark Outlet -01 SE Open Office SE Open Office DT3-Titus MCD 10110 310 380 123 330 106 40% closed Outlet -02 SE Open Office SE Open Office DT3-Titus MCD 10/10 310 440 142 335 108 40% closed Outlet -03 SE Open Office SE Open Office DT3-Titus MCD 10/10 310 305 98 335 108 key Totals: - 930 o 1125 0 121 0 1000 0 108 0 - Hermanson Mermanson Air Handling Unit PROJECT: LEO STELLA TI LOCATION: Tukwila, WA PROJECT #: 21-18-13166 DATE: 4/15/2019 CONTACT: Kevin Gibson AUTHOR: Kevin Gibson WE BUILD !RsS.'2bsfiU7kitSiFS 0r..uv��, Itt5r1ALO RESULTS SYSTEM/UNIT: AHU-Existing/FP-1 B-09 AREA: 1st Floor Unit Data Manufacturer Model Number Serial Number VAV Address Box Inlet Size K Factor Remark Krueger KQFS•-3-12 18-733456-C-006 9 12 1952.000 Open Office AHU-Existing/FP-1 B-09 Supply Outlet Summary Tested By: Kevin Gibson Date: 4/15/2019 Term Box Test Data VAV Fan Design VAV Fan Actual Design Max Airflow Design Min Airflow 930 CFM L/S 980 CFM L/S 925 CFM L/S 290 CFM L/S System/Unit Area Served Outlet Type Size LxW / D Design Airflow Prelim Airflow % Prelim Diff. Final Airflow % Final Diff. Remark Outlet -01 West Open Office West Open Office DT3-Titus MCD 10/10 310 260 84 310 100 key Outlet -02 West Open Office West Open Office DT3-Titus MCD 10/10 310 280 90 340 110 Outlet -03 West Open Office West Open Office DT3-Titus MCD 10/10 310 270 87 330 106 Totals: -- 930 0 810 0 87 0 980 0 105 0 - Hermanson hlermanson Air Handling Unit PROJECT: LEO STELLA TI LOCATION: Tukwila, WA PROJECT #: 21-18-13166 DATE: 4/15/2019 CONTACT: Kevin Gibson AUTHOR: Kevin Gibson WE BUILD t e KtAtr O[ t� 8t L0 RESULTS SYSTEM/UNIT: AHU-Existing/FP-1B-10 AREA: 1st Floor Unit Data Manufacturer Model Number Serial Number VAV Address Box Inlet Size K Factor Max Setpoint Min Setpoint Reheat Setpoint Remark Nailor Industries D35SE 128910-48 30 16 1980.000 2550 205 70 Original VAV- Non-Ecm Motor AHU-Existing/FP-1B-10 Supply Outlet Summary Tested By: Kevin Gibson Date: 4/15/2019 Term Box Test Data VAV Fan Design VAV Fan Actual Design Max Airflow Actual Max Airflow Design Min Airflow Actual Min Airflow 2000 CFM L/S 1920 CFM US 2500 CFM US 1920 CFM LIS 205 CFM US 200 CFM L/S System/Unit Area Served Outlet Type Size LxW / D Design Airflow Prelim Airflow % Prelim Diff. Final Airflow % Final Diff. Remark VAV-1-10-Outlet -01 1st Floor -Main Building Entry- South 1st Floor -Main Building Entry - South LSD 4/48". 10" 415 170 41 410 99 Atrium -SE- closed 80% VAV-1-10-Outlet -02 1st Floor -Main Building Entry- South 1st Floor -Main Building Entry - South LSD 4/48". 10" 415 550 133 390 94 Atrium- closed 90% VAV-1-10-Outlet -03 1st Floor -Main Building Entry- South 1st Floor -Main Building Entry - South LSD 4/48". 10" 415 130 31 420 101 Atrium- Above East Door- Key VAV-1-10-Outlet -04 1st Floor -Main Building Entry- South 1st Floor -Main Building Entry- South LSD 4/48". 10" 415 120 29 420 101 Atrium- Above West Doors - closed 70% VAV-1-10-Outlet -05 lst Floor -Main Building Entry- South 1st Floor -Main Building Entry - South LSD 4/48" 415 360 87 410 99 Atrium- closed 70% VAV-1-10-Outlet -06 1st Floor -Main Building Entry- South 1st Floor -Main Building Entry - South LSD 4/48" 415 590 142 440 106 Atrium- SW - Closed 85% Totals: - 2490 0 1920 0 77 0 2490 0 100 0 - Hermanson )Hermanson Air Handling Unit PROJECT: LEO STELLA TI LOCATION: Tukwila, WA PROJECT #: 21-18-13166 DATE:: 4/15/2019 CONTACT! Kevin Gibson AUTHOR: Kevin Gibson WE BUILD 8 Di_uvEIRCOPIRLO RESULTS SYSTEM/UNIT: AHU-Existing/FP-18-25 AREA: 1st Floor Unit Data Manufacturer Model Number Serial Number VAV Address Box Inlet Size K Factor Remark Krueger KQFS- 6-14 18-733456-C-007 10 14 2709.000 Clean Room (int) AHU-Existing/FP-1B-25 Supply Outlet Summary Tested By: Kevin Gibson Date: 4/15/2019 Term Box Test Data VAV Fan Design VAV Fan Actual Design Max Airflow Design Min Airflow 1580 CFM US 875 CFM US 1580 CFM US 475 CFM US System/Unit Area Served Outlet Type Size LxW / 0 Design Airflow Prelim Airflow % Prelim Diff. Final Airflow % Final Diff. Remark Outlet -01 Clean Room Clean Room DT3-Titus MCD 10/10 240 290 121 230 96 : closed 50% Outlet -02 Clean Room Clean Room DT3-Titus MCD 10/10 240 250 104 215 90 closed 40% Outlet -03 Clean Room Clean Room DT3-Titus MCD 10/10 240 180 75 215 90 key Outlet -04 Clean Room Clean Room DT3-Titus MCD 10/10 240 215 90 215 90 closed 30% Totals: - - 960 0 935 0 97 0 875 0 91 0 - Hermanson )Hermanson Air Handling Unit PROJECT: LEO STELLA TI LOCATION: Tukwila, WA PROJECT #: 21-18-13166 DATE: 4/15/2019 CONTACT: Kevin Gibson AUTHOR: Kevin Gibson WE BUILD O :}4 RL0 RESULTS SYSTEM/UNIT: AHU-Existing/FP-1B-28 AREA: 1st Floor Unit Data Manufacturer Model Number Serial Number VAV Address Box Inlet Size K Factor Remark Krueger KQFS-3-10 18-733456-C-008 11 10 1450.000 Fan Maxed flow at 72% Log: Tested By: Kevin Gibson Date: 4/15/2019 Term Box Test Data VAV Fan Design VAV Fan Actual Design Max Airflow Design Min Airflow 780 CFM US 630 CFM US 780 CFM L/S 235 CFM US AHU-Existing/FP-1 B-28 4/15/2019 Kevin Gibson FP -1 B-28: VAV supply air through HEPA filters. Supply Air @ 81% of Design AHU-Existing/FP-1 B-28 Supply Outlet Summary System/Unit Area Served Outlet Type Size LxW / D Design Airflow Prelim Airflow % Prelim Diff. Final Airflow % Final Diff. Remark Outlet -01 Clean Room Clean Room DT3-Titus MCD 10/10 260 170 65 210 81 key Outlet -02 Clean Room Clean Room DT3-Titus MCD 10/10 260 240 92 210 81 closed 30% Outlet -03 Clean Room Clean Room DT3-Titus MCD 10/10 260 225 87 210 81 closed 20% Totals: - - 780 0 635 0 81 0 630 0 81 0 - Hermanson Hermanson Air Handling Unit PROJECT: LEO STELLA TI LOCATION: Tukwila, WA PROJECT #: 21-18-13166 IMO IOIMOSIOMaf off• DATE: 4/15/2019 CONTACT: Kevin Gibson AUTHOR: Kevin Gibson g WE BUILD T ..,••ts f3LA1.Ds 45' ZS DUMP INSv1RTtt RESULTS SYSTEM/UNIT: AHU-Existing/FP-1 B-29 AREA: 1st Floor Unit Data Manufacturer Krueger Model Number KQFS-3-6 Serial Number 18-733456-C-009 VAV Address 12 Box Inlet Size 6 K Factor 360.000 Airlock, 16/20/1", fan off for low desi • n. Remark Log: Tested By: Kevin Gibson Date: 4/15/2019 Term Box Test Data VAV Fan Design VAV Fan Actual Design Max Airflow Design Min Airflow 30 CFM US 30 CFM US 30 CFM US 30 CFM US AHU-Existing/FP-1 B-29 12/7/2018 Kevin Gibson To be able to maintain the newest print Supply Airflow of 30 cim, Supply Fan is Disabled and the Valve is Maintaining Airflow AHU-Existing/FP-1 B-29 Supply Outlet Summary System/Unit Area Served Outlet Type Size LxW / D Design Airflow Prelim Airflow % Prelim Diff. Final Airflow % Final Diff. Remark Outlet -01 Clean Room Clean Room DT1-Titus MCD 6/6 30 210 700 30 100 Fan Off, Adjusted Outlet -02 Cafeteria Cafeteria DT2-Titus MCD 8/8 210 220 105 205 98 Valve CFM for design Totals: - - 30 210 700 30 100 - 0 0 0 0 0 SYSTEM/UNIT: AHU-Existing/FP-1B-30 AREA: 1st Floor Unit Data Manufacturer Krueger Model Number KQFS-3-8 Serial Number 18-733456-C-010 VAV Address 13 Box Inlet Size 8 K Factor 969.000 Cafeteria (Int). Fan Speed 42% Remark AHU-Existing/FP-1 B-30 Supply Outllet Summary Tested By: Kevin Gibson Date: 4/15/2019 Term Box Test Data VAV Fan Design VAV Fan Actual Design Max Airflow Actual Max Airflow Design Min Airflow 420 CFM L/S 425 CFM US 420 CFM L/S 435 CFM L/S 135 CFM L/S System/Unit Area Served Outlet Type Size LxW / D Design Airflow Prelim Airflow % Prelim Diff. Final Airflow % Final Diff. Remark Outlet -01 Cafeteria Cafeteria DT2-Titus MCD 8/8 210 215 102 220 105 key Outlet -02 Cafeteria Cafeteria DT2-Titus MCD 8/8 210 220 105 205 98 Totals: - - 420 0 435 0 104 0 425 0 101 0 - Hermanson Hermanson Air Handling Unit PROJECT: LEO STELLA TI LOCATION: Tukwila, WA PROJECT #: 21-18-13166 DATE: 4/15/2019 CONTACT: Kevin Gibson AUTHOR: Kevin Gibson WE BUILD f: UTLASPS 3 Ct-LI47R 1,01k[d RESULTS SYSTEM/UNIT: AHU-Existing/FP-1 B-31 AREA: 1st Floor Unit Data Manufacturer Model Number Serial Number VAV Address Box Inlet Size K Factor Remark Krueger KQFS-3-8 18-733456-C-011 14 8 845.000 Open Office (Int) Fan speed 37% AHU-Existing/FP-1 B-31 Supply Outlet Summary Tested By: Kevin Gibson Date: 4/15/2019 Term Box Test Data VAV Fan Design VAV Fan Actual Design Max Airflow Design Min Airflow 360 CFM US 385 CFM L/S 360 CFM L/S 215 CFM L/S System/Unit Area Served Outlet Type Size LxW / D Design Airflow Prelim Airflow % Prelim Diff. Final Airflow % Final Diff. Remark Outlet -01 East Open Office East Open Office DT2-Titus MCD 8/8 180 180 100 195 108 closed 15% Outlet -02 East Open Office East Open Office DT2-Titus MCD 8/8 180 160 89 190 106 key Totals: - - 360 0 340 0 94 0 385 0 107 0 - Hermanson )Hermanson Air Handling Unit PROJECT: LEO STELLA TI LOCATION: Tukwila, WA PROJECT #: 21-18-13166 DATE: 4/15/2019 CONTACT Kevin Gibson AUTHOR: Kevin Gibson WE BUILD Ti.STI.r:. FL-LAD:VS.4 FS 5 DELVE.P. iwSr1fiL0 RESULTS SYSTEM/UNIT: AHU-Existing/FP-1B-32 AREA: 1st Floor Unit Data Manufacturer Krueger Model Number KQFS-3-6 Serial Number 18-733456-C-012 VAV Address 15 Box Inlet Size 6 K Factor 609.000 Remark Phone Rooms Log: Tested By: Kevin Gibson Date: 4/15/2019 Term Box Test Data VAV Fan Design VAV Fan Actual Design Max Airflow Design Min Airflow 120 CFM LIS 280 CFM us 120 CFM us 65 CFM us AHU-Existing/FP-1B-32 4/15/2019 Kevin Gibson FP -1B-32: Slowed Fan to minimum CFM for EHS. AHU-Existing/FP-1B-32 Supply Outlet Summary System/Unit Area Served Outlet Type Size LxW / D Design Airflow Prelim Airflow % Prelim Diff. Final Airflow % Final Diff. Remark Outlet -01 East Open Office East Open Office DT2-Titus MCD 8/8 120 160 133 120 100 50% Closed Outlet -02 East Open Office East Open Office DT1-Titus MCD 6/6 25 75 300 80 320 100% closed Outlet -03 East Open Office East Open Office DT1-Titus MCD 6/6 25 40 160 80 320 90% closed Totals: - - 170 0 275 0 162 0 280 0 165 0 - Hermanson )Hermanson Air Handling Unit PROJECT: LEO STELLA TI LOCATION: Tukwila, WA PROJECT #: 21-18-13166 DATE: 4/15/2019 CONTACT: Kevin Gibson AUTHOR: Kevin Gibson WE BUILD SQLST F.C1 kTI,AS,4Ya: t ivtAk RESULTS SYSTEM/UNIT: AHU-Existing/FP-1B-33 AREA: 1st Floor Unit Data Manufacturer Model Number Serial Number VAV Address Box Inlet Size K Factor Remark Krueger KQFS-3-8 18-733456-C-013 16 8 871.000 Open Office (Int) Fan @47% AHU-Existing/FP-1 B-33 Supply Outlet Summary Tested By: Kevin Gibson Date: 4/15/2019 Term Box Test Data VAV Fan Design VAV Fan Actual Design Max Airflow Design Min Airflow 495 CFM L/S 510 CFM L/S 495 CFM US 125 CFM L/S System/Unit Area Served Outlet Type Size LxW / D Design Airflow Prelim Airflow % Prelim Diff. Final Airflow % Final Diff. Remark Outlet -01 Open Office Open Office DT2-Titus MCD 8/8 165 200 121 170 103 key Outlet -02 Open Office Open Office DT2-Titus MCD 8/8 165 215 130 175 106 - Outlet -03 Open Office Open Office DT2-Titus MCD 8/8 165 240 145 165 100 closed 20% Totals: - - 495 0 655 0 132 0 510 0 103 0 - SYSTEM/UNIT: AHU-Existing/FP-1 B-34 AREA: 1st Floor Unit Data Manufacturer Model Number Serial Number VAV Address Box Inlet Size K Factor Remark Krueger KQFS-3-8 18-733456-C-014 17 8 845.000 Equipment & Sub -Assembly 20% fan speed AHU-Existing/FP-1 B-34 Supply Outlet Summary Tested By: Kevin Gibson Date: 12/10/2018 Term Box Test Data VAV Fan Design VAV Fan Actual Design Max Airflow Design Min Airflow 270 CFM L/S 295 CFM L/S 270 CFM L/S 125 CFM US System/Unit Area Served Outlet Type Size LxW / D Design Airflow Prelim Airflow % Prelim Diff. Final Airflow % Final Diff. Remark Outlet -01 Incoming/ Storage Incoming/ Storage DT3-Titus MCD 10/10 270 70 26 295 109 Totals: - - 270 0 70 0 26 0 295 0 109 0 - Hermanson )Hermanson Air Handling Unit PROJECT: LEO STELLA TI LOCATION: Tukwila, WA PROJECT #: 21-18-13166 DATE 4/15/2019 CONTACT:: Kevin Gibson AUTHOR: Kevin Gibson WE BUILD & OEIMP. f:$1 LO RESULTS SYSTEM/UNIT: AHU-Existing/FP-1B-35 AREA: lst Floor Unit Data Manufacturer Model Number Serial Number VAV Address Box Inlet Size K Factor Remark Krueger KQFS-3-8 18-733456-C-015 18 8 1035.000 Open Office (Int) AHU-Existing/FP-1B-35 Supply Outlet Summary Tested By: Kevin Gibson Date: 4/15/2019 Term Box Test Data VAV Fan Design VAV Fan Actual Design Max Airflow Design Min Airflow 465 CFM L/S 475 CFM US 465 CFM US 140 CFM US System/Unit Area Served Outlet Type Size LxW 1 D Design Airflow Prelim Airflow % Prelim Diff. Final Airflow % Final Diff. Remark Outlet -01 Open Office Open Office DT1-Titus MCD 6/6 90 75 83 85 94 key Outlet -02 Open Office Open Office DT2-Titus MCD 8/8 150 170 113 165 110 20% closed Outlet -03 Open Office Open Office 0T2 -Titus MCD 8/8 150 180 120 150 100 30% closed Outlet -04 Open Office Open Office DT1-Titus MCD 6/6 75 75 100 75 100 25% closed Totals: - - 465 0 500 0 108 0 475 0 102 0 - SYSTEM/UNIT: AHU-Existing/FP-1B-36 AREA: 1st Floor Unit Data Manufacturer Model Number Serial Number VAV Address Box Inlet Size K Factor Remark Krueger KQFS-3-8 18-733457-C-001 19 8 1108.000 Flat SAT AHU-Existing/FP-1B-36 Supply Outlet Summary Tested By: Kevin Gibson Date: 4/15/2019 Term Box Test Data VAV Fan Design VAV Fan Actual Design Max Airflow Design Min Airflow 165 CFM US 180 CFM L/S 165 CFM US 125 CFM L/S System/Unit Area Served Outlet Type Size LxW / D Design Airflow Prelim Airflow % Prelim Diff. Final Airflow % Final Diff. Remark Outlet -01 Flat Sat Flat Sat DT1-Titus MCD 6/6 85 90 106 90 106 Outlet -02 Flat Sat Flat Sat DT1-Titus MCD 6/6 85 90 106 90 106 Totals: - - 170 o 180 0 106 0 180 0 106 0 - Hermanson )Hermanson Air Handling Unit PROJECT: LEO STELLA TI LOCATION: Tukwila, WA PROJECT #: 21-18-13166 DATE: 4/15/2019 CONTACT: Kevin Gibson AUTHOR: Kevin Gibson WE BUILD asrisap. L*T ,s,s: ©.UNU:tR IND) RESULTS SYSTEM/UNIT: AHU-Existing/FP-1B-37 AREA: 1st Floor Unit Data Manufacturer Krueger Model Number KQFS-3-6 Serial Number 18-733457-C-002 VAV Address 20 Box Inlet Size 6 K Factor 639.100 Blg. Security (Exist)@ Minimum Fan Speed for box Remark AHU-Existing/FP-1 B-37 Supply Outlet Summary Tested By: Kevin Gibson Date: 4/15/2019 Term Box Test Data VAV Fan Design VAV Fan Actual Design Max Airflow Actual Max Airflow Design Min Airflow 90 CFM US 150 CFM US 90 CFM LIS 150 CFM US 30 CFM us System/Unit Area Served Outlet Type Size LxW / D Design Airflow Prelim Airflow % Prelim Diff. Final Airflow % Final Diff. Remark Outlet -01 Building Security Station Building Security Station 2WC 5/5 90 150 167 150 167 Outlet -02 Totals: - - 90 0 150 0 167 0 150 0 167 0 SYSTEM/UNIT: AHU-Exiisting/FP-1B-38 AREA: 1st Floor Unit Data Manufacturer Model Number Serial Number VAV Address Box Inlet Size K Factor Remark Krueger KQFS-3-8 18-733457-C-003 21 8 958.500 Conference (S. Ext) AHU-Existing/FP-1 B-38 Supply Outlet Summary Tested By: Kevin Gibson Date: 4/15/2019 Term Box Test Data VAV Fan Design VAV Fan Actual Design Max Airflow Design Min Airflow 530 CFM US 575 CFM L/S 530 CFM US 160 CFM us System/Unit Area Served Outlet Type Size LxW I D Design Airflow Prelim Airflow % Prelim Diff. Final Airflow % Final Diff. Remark Outlet -01 Conference - 101 Conference - 101 DT3-Titus MCD 10/10 265 110 42 290 109 Outlet -02 Conference - 101 Conference - 101 DT3-Titus MCD 10/10 265 120 45 285 108 Totals: - - 530 0 230 0 43 0 575 0 108 0 - Hermanson )Hermanson Air Handling Unit PROJECT: LEO STELLA TI LOCATION: Tukwila, WA PROJECT #: 21-18-13166 DATE: 4/15/2019 CONTACT:: Kevin Gibson AUTHOR: Kevin Gibson WE BUILD »ST?Y. PILATb3V;43,S RESULTS SYSTEM/UNIT: AHU-Existing/FP-1B-39 AREA: 1st Floor Unit Data Manufacturer Krueger Model Number KQFS-3-8 Serial Number 18-733457-C-004 VAV Address 22 Box Inlet Size 8 K Factor 1026.000 Remark Phone Rooms/ Open Office Fan S.eed 20% minimum AHU-Existing/FP-1B-39 Supply Outlet Summary Tested By: Kevin Gibson Date: 4/15/2019 Term Box Test Data VAV Fan Design VAV Fan Actual Design Max Airflow Design Min Airflow 225 CFM L/S 275 CFM L/S 225 CFM US 125 CFM L/S System/Unit Area Served Outlet Type Size LxW 1 D Design Airflow Prelim Airflow % Prelim Diff. Final Airflow % Final Diff. Remark Outlet -01 West Open Office West Open Office DT1-Titus MCD 6/6 25 100 400 35 140 100% closed Outlet -02 West Open Office West Open Office DT1-Titus MCD 6/6 35 225 643 50 143 90% closed Outlet -03 West Open Office West Open Office DT2-Titus MCD 8/8 165 100 61 190 115 Open Office, key Totals: - - 225 0 425 a 189 0 275 0 122 0 - Hermanson Hermanson Air Handling Unit PROJECT: LEO STELLA TI LOCATION: Tukwila, WA PROJECT #: 21-18-13166 DATE: 4/15/2019 CONTACT: Kevin Gibson AUTHOR: Kevin Gibson WE BUILD M.S:34. KLATY:AS,;Y, : is+Rto RESULTS SYSTEM/UNIT: AHU-Existing/FP-16-40 AREA: 1st Floor Unit Data Manufacturer Model Number Serial Number VAV Address Box Inlet Size K Factor Remark Krueger KQFS-3-8 18-733457-C-005 23 8 827.000 Meeting Room , Fan speed minimum AHU-Existing/FP-1 B-40 Supply Outlet Summary Tested By: Kevin Gibson Date: 4/15/2019 Term Box Test Data VAV Fan Design VAV Fan Actual Design Max Airflow Design Min Airflow 330 CFM L/S 340 CFM us 330 CFM US 125 CFM US System/Unit Area Served Outlet Type Size LxW / D Design Airflow Prelim Airflow % Prelim Diff. Final Airflow % Final Diff. Remark Outlet -01 Clean Room office Clean Room office DT2-Titus MCD 8/8 155 200 129 170 110 20% closed Outlet -02 Clean Room office Clean Room office DT2-Titus MCD 8/8 155 235 152 170 110 closed 20% Totals: - - 310 0 435 0 140 0 340 0 110 0 - SYSTEM/UNIT: AHU-Existing/FP-1 B-44 AREA: 1st Floor Unit Data Manufacturer Model Number Serial Number VAV Address Box Inlet Size K Factor Remark Krueger KQFS-3-10 18-733457-C-006 24 10 1552.000 Cafeteria (S. Ext) New Fan Speed @60% AHU-Existing/FP-1 B-44 Supply Outlet Summary Tested By: Kevin Gibson Date: 4/15/2019 Term Box Test Data VAV Fan Design VAV Fan Actual Design Max Airflow Actual Min Airflow 570 CFM L/S 610 CFM US 570 CFM L/S 225 CFM L/S System/Unit Area Served Outlet Type Size LxW / D Design Airflow Prelim Airflow % Prelim Diff. Final Airflow % Final Diff. Remark Outlet -01 Cafeteria Cafeteria DT4-Titus MCD 12/12 285 440 154 310 109 Outlet -02 Cafeteria Cafeteria DT4-Titus MCD 12/12 285 485 170 300 105 closed 20% Totals: - - 570 0 925 0 162 0 610 0 107 0 - Hermanson Nermanson Air Handling Unit PROJECT: LEO STELLA TI LOCATION: Tukwila, WA PROJECT #: 21-18-13166 DATE: 4/15/2019 CONTACT: Kevin Gibson AUTHOR.: Kevin Gibson WE BUILD I2:.33' MAU:AS-4AS OLL RESULTS SYSTEM/UNIT: AHU-Existing/FP-1IB-45 AREA: 1st Floor Unit Data Manufacturer Model Number Serial Number VAV Address Box Inlet Size K Factor Remark Krueger KQFS-3-10 18-733457-C-008 25 10 1381.000 Clean Room (N. Ext) @70% r. m AHU-Existing/FP-1 B-45 Supply Outlet Summary Tested By: Kevin Gibson Date: 4/15/2019 Terry Box Test Data VAV Fan Design VAV Fan Actual Design Max Airflow Design Min Airflow 560 CFM us 520 CFM us 560 CFM uS 225 CFM US System/Unit Area Served Outlet Type Size LxW / D Design Airflow Prelim Airflow % Prelim Diff. Final Airflow % Final Diff. Remark Outlet -01 Clean Room Clean Room DT3-Titus MCD 10/10 280 240 86 260 93 key Outlet -02 Clean Room Clean Room DT3-Titus MCD 10/10 280 270 96 260 93 20% closed Totals: - - 560 0 510 0 91 0 520 0 93 0 - SYSTEM/UNIT: AHU-Existing/FP-1B-46 AREA: 1st Floor Unit Data Manufacturer Krueger Model Number KQFS-3-6 Serial Number 18-733457-C-008 VAV Address 26 Box Inlet Size 6 K Factor 483.000 Remark Incoming Storage / @Fan Saeed Minimum AHU-Existing/FP-1B-46 Supply Outlet Summary Tested By: Kevin Gibson Date: 4/15/2019 Term Box Test Data VAV Fan Design VAV Fan Actual Design Max Airflow Design Min Airflow 110 CFM L/S 270 CFM L/S 110 CFM L/S 65 CFM L/S System/Unit Area Served Outlet Type Size LxW / D Design Airflow Prelim Airflow % Prelim Diff. Final Airflow % Final Diff. Remark Outlet -01 Incoming/ Storage Incoming/ Storage DT1—Titus MCD 6/6 55 140 255 135 245 closed 10% Outlet -02 Incoming/ Storage Incoming/ Storage DT1-Titus MCD 6/6 55 110 200 135 245 key Totals: - - 110 0 250 0 227 0 270 0 245 0 - Hermanson }Hermanson Air Handling Unit PROJECT: LEO STELLA TI LOCATION: Tukwila, WA PROJECT #: 21-18-13166 DATE: 4/15/2019 CONTACT: Kevin Gibson AUTHOR: Kevin Gibson WE BUILD "r4.4:1•4 LOr tY,S P $ MAP: imSPIREO RESULTS SYSTEM/UNIT: AHU-Existing/FP-1B-48 AREA: lst Floor Unit Data Manufacturer Model Number Serial Number VAV Address Box Inlet Size K Factor Remark Krueger KQFS-3-8 18-7333457-C-010 27 8 892.000 North Lobby / @ Fan Maximum AHU-Existing/FP-1B-48 Supply Outlet Summary Tested By: Kevin Gibson Date: 4/15/2019 Term Box Test Data VAV Fan Design VAV Fan Actual Design Max Airflow Design Min Airflow 1000 CFM L/S 970 CFM L/S 1000 CFM L/S 200 CFM LIS System/Unit Area Served Outlet Type Size LxW / D Design Airflow P^elim Airflow % Prelim Diff. Final Airflow % Final Diff. Remark Outlet -01 Central Lobby Central Lobby RD3 Round 10 250 120 48 240 96 key Outlet -02 Central Lobby Central Lobby RD3 Round 10 250 120 48 240 96 closed 10% Outlet -03 Central Lobby Central Lobby DT5-Titus MCD 14/14 500 255 51 490 98 Totals: - 1000 0 495 0 50 0 970 0 97 0 - Hermanson lHermanson Fan Unit PROJECT: LEO STELLA TI LOCATION: Tukwila, WA PROJECT #: 21-18-13166 1 M.* aluorgm1.0-1014.4.400 OW* DATE, 4/15/2019 CONTACT:: Kevin Gibson AUTHOR:: Kevin Gibson WE BUILD 1$v'..:1ti� YxSASk.t.ix $ $OfUv {tw[O RESULTS SYSTEM/UNIT: EF -1B Restroom Exhaust Unit Data Fan Manufacturer CENTRI MASTER Fan Model Number PV200 Fan Serial Number YYF851203 Rated Airflow Capacity 3105 CFM US Test Data Design Airflow 1530 CFM US Log: Tested By: Kevin Gibson Date: 4/15/2019 Motor Data Motor Manufacturer Motor Frame Motor HP Motor RPM Motor Rated Volts Motor Phase Motor Hertz Not Legible Not Legible 1 HP HP 924 RPM RPM 230/460 Volts Volts 3 60 Hz Hz Sheave Data Belt Size AX -30 EF -1 B Restroom Exhaust 12/11/2018 Kevin Gibson EF -1 B Distech Address: 31 EF -1B Restroom Exhaust Exhaust Inlet Summary System/Unit Area Served Inlet Type Size LxW / D Design Airflow Prelim Airflow % Prelim Diff. Final Airflow % Final Diff. Remark EF -Inlet -01- Floor -1 Restrooms Restrooms G1 -Titus 350FL AG- 15 10/10 100 90 90 100 100 Bike Storage - North EF -Inlet -02- Floor -1 Restrooms Restrooms G1 -Titus 350FL AG- 15 10/10 30 80 267 33 110 Bike Change RM - Closed 85% EF -Inlet -03- Floor -1 Restrooms Restrooms G1 -Titus 350FL AG- 15 10/10 100 105 105 100 100 Bike RM Shower - Closed 20% EF -Inlet -04- Floor -1 Restrooms Restrooms EAR 10/10 300 270 90 270 90 Women's Restroom - North EF -Inlet -05- Floor -1 Restrooms Restrooms EAR 10/10 300 275 92 280 93 Women's Restroom - South EF -Inlet -06- Floor -1 Restrooms Restrooms EAR 10/10 300 270 90 270 90 Men's Restroom - North EF -Inlet -07- Floor -1 Restrooms Restrooms EAR 10/10 300 315 105 310 103 Men's Restroom - South EF -Inlet -08- Floor -1 Restrooms Restrooms EAR 8/8 100 45 45 95 95 Men RR - Janitor's RM -Closed 80% Totals: - - 1530 0 1450 0 95 0 1458 0 95 0 - Hermanson hiermanson Fan Unit PROJECT: LEO STELLA TI LOCATION: Tukwila, WA PROJECT #: 21-18-13166 r; 6. nimmaimem.• ••••••• DATE: 4/15/2019 CONTACT: Kevin Gibson AUTHOR: Kevin Gibson WE BUILD KUM° 4 P: & or -UVEA NIA PLO RESULTS SYSTEM/UNIT: H -1B-01 AREA: lst Floor Unit Data Fan Manufacturer Fan Model Number Fan Serial Number Rated Airflow Capacity Nortec EL Space /RMBP 030/208/3 2289657 656 CFM LIS Test Data Design Airflow Actual Airflow Motor Volts T1-T2 Motor Volts T2-T3 Motor Volts T1-T3 Motor Amps Ti Motor Amps T2 Motor Amps T3 656 CFM 1/S 550 high / 320 low CFM US 207 Volts Volts 205 Volts Volts 206 Volts Volts 4.20 Amps Amps 4.60 Amps Amps 4.60 Amps Amps Log: Tested By: Kevin Gibson Date: 3/25/2019 Motor Data Motor Rated Volts Motor Phase Motor Hertz 208 Volts Volts 3 60 Hz Hz H -1B-01 12/7/2018 Kevin Gibson Humidifier range of operation : 40-60% Set all at 40.5, per request of Leo Stella Hermanson )Hermanson Fan Unit PROJECT: LEO STELLA TI LOCATION: Tukwila, WA PROJECT #: 21-18-13166 DATE: 4/15/2019 CONTACT: Kevin Gibson AUTHOR: Kevin Gibson WE BUILD iiSry7[V. fiUTa?%51.F5 s ori n2c: NSA [0 RESULTS SYSTEM/UNIT: H -1B-02 AREA: lst Floor Unit Data Fan Manufacturer Fan Model Number Fan Serial Number Rated Airflow Capacity Nortec EL Space/RMBP 030/208/3 2289656 938 CFM LIS Test Data Design Airflow Actual Airflow Motor Volts T1-T2 Motor Volts T2-T3 Motor Volts T1-T3 Motor Amps T1 Motor Amps T2 Motor Amps T3 938 CFM US 505 high/350 low CFM US 207 Volts Volts 205 Volts Volts 206 Volts Volts 5.70 Amps Amps 5.40 Anips Amps 5.00 Anips Amps Log: Tested By: Kevin Gibson Date: 3/25/2019 Motor Data Motor Rated Volts Motor Phase Motor Hertz 208 Volts Volts 3 60 Hz Hz H-1 B-02 12/7/2018 Kevin Gibson Condensate pump Hermanson hiermanson Fan Unit PROJECT: LEO STELLA TI LOCATION: Tukwila, WA PROJECT #: 21-18-13166 DATE: 4/15/2019 CONTACT: Kevin Gibson AUTHOR: Kevin Gibson WE BUILD T%571%.7..t3LLTk3+:ti5 8DEMP ff t!4SxtRL0 RESULTS SYSTEM/UNIT: H-1 B-03 AREA: 1st Floor Unit Data Fan Manufacturer Fan Model Number Fan Serial Number Rated Airflow Capacity Nortec EL Space/RMBP 030/208/3 2289655 938 CFM US Test Data Design Airflow Actual Airflow Motor Volts T1-T2 Motor Volts T2-T3 Motor Volts T1-T3 Motor Amps T1 Motor Amps T2 Motor Amps T3 938 CFM L/S 600 high / 320 low CFM vs 209 Volts Volts 207 Volts Volts 207 Volts Volts 5.90 Amps Amps 5.90 Amps Amps 5.30 Amps Amps Tested By: Kevin Gibson Date: 3/25/2019 Motor Data Motor Rated Volts Motor Phase Motor Hertz 208 Volts Volts 3 60 Hz Hz SYSTEM/UNIT: H-1 B-04 AREA: 1st Floor Unit Data Fan Manufacturer Fan Model Number Fan Serial Number Rated Airflow Capacity Nortec EL SPACE/RMBP 030/208/3 2289564 679 CFM US Starter Data Required Amps 40.00 Amps Amps Test Data Design Airflow Actual Airflow Motor Volts T1-T2 Motor Volts T2-T3 Motor Volts T1-T3 Motor Amps T1 679 CFM L/S 640/960 CFM US 210 Volts Volts 210 Volts Volts 211 Volts Volts 0.4/ 0.6 Amps Amps Tested By: Kevin Gibson Date: 3/28/2019 Motor Data Motor Rated Volts Motor Phase Motor Hertz 208 Volts Volts 3 60 Hz Hz Hermanson )Hermanson Fan Unit PROJECT: LEO STELLA TI LOCATION: Tukwila, WA PROJECT #: 21-18-13166 DATE: 4/15/2019 CONTACT: Kevin Gibson AUTIHOR: Kevin Gibson WE BUILD RESULTS SYSTEM/UNIT: H-1 B-05 AREA: 1st Floor Unit Data Fan Manufacturer Fan Model Number Fan Serial Number Rated Airflow Capacity Nortec EL Space/RMBP 020/208/1 2289653 417 CFM L/S Test Data Design Airflow Actual Airflow Motor Volts T1-T2 Motor Amps T1 417 CFM US 525 high / 420 low CFM US 205 Volts Volts Total CO 10.110.1 Amps Ames Tested By: Kevin Gibson Date: 3/25/2019 Motor Data Motor Rated Volts Motor Phase Motor Hertz 208 Volts Volts 1 60 Hz Hz SYSTEM/UNIT: H-1 B-06 AREA: 1st Floor Unit Data Fan Manufacturer Fan Model Number Fan Serial Number Rated Airflow Capacity Nortec EL Space/ RMBP 010/208/1 2289652 203 CFM US Design Airflow Actual Airflow Motor Volts T1-T2 Motor Amps T1 Test Data 203 CFM L/S 580 high / 410 low CFM L/S 203 Volts Volts Total 7.1 / 7.2 Amps Am.s Tested By: Kevin Gibson Date: 3/25/2019 Motor Data Motor Rated Volts Motor Phase Motor Hertz 208 Volts Volts 1 60 Hz Hz Hermanson �}Hermanson Fan Unit PROJECT: LEO STELLA TI LOCATION: Tukwila, WA PROJECT #: 21-18-13166 11...11.--..--- DATE: 4/15/2019 CONTACT: Kevin Gibson AUTHOR: Kevin Gibson WE BUILD " STIv:FSL.h.NS,11,S s OtuP£k suSnu[o RESULTS SYSTEM/UNIT: SF -1B-01 AREA: 1st Floor Unit Data Fan Manufacturer Fan Model Number Fan Serial Number Rated Airflow Capacity Twin City Fan DSI-150AE 118-00000261900 2300 CFM L/S Test Data Design Airflow Motor Volts T1-T2 Motor Amps T1 2300 CFM L/S 209 Volts Volts 9.8 @ 80% Amps Amps Log: Tested By: Kevin Gibson Date: 3/25/2019 Motor Data Motor Manufacturer Motor Frame Motor HP Motor RPM Motor Rated Volts Motor Phase Motor Hertz Motor FL Amps Baldor Direct Drive 2 HP HP 1800 RPM RPM 208-230 Volts Volts 1 60 Hz Hz 12.00 Amps Amps SF -1 B-01 12/11/2018 Kevin Gibson All SF Distech Address: 29 SF -1B-01 Supply Outlet Summary System/Unit Area Served Outlet Type Size LxW / D Design Airflow Prelim Airflow % Prelim Diff. Final Airflow % Final Diff. Remark Outlet -01 Clean Room Clean Room DT5-Titus MCD 14/14 575 575 100 520 90 50% closed Outlet -02 Clean Room Clean Room DT5-Titus MCD 14/14 575 560 97 520 90 40% closed Outlet -03 Clean Room Clean Room DT5-Titus MCD 14/14 575 490 85 520 90 15% closed Outlet -04 Clean Room Clean Room DT5-Titus MCD 14/14 575 430 75 520 90 key Totals: - - 2300 0 2055 0 89 0 2080 0 90 0 - SF -1B-01 Return Inlet Summary System/Unit Area Served Inlet Type Size LxW / D Design Airflow Prelim Airflow % Prelim Diff. Final Airflow % Final Diff. Remark RA Inlet -01 Clean Room Clean Room G2 -Titus 350FL AG - 15 20/20 2300 2410 105 2240 97 Totals: - - 2300 0 2410 0 105 0 - 97 0 - Hermanson Hermanson Fan Unit PROJECT: LEO STELLA TI LOCATION: Tukwila, WA PROJECT #: 21-18-13166 DATE, 4/15/2019 CONTACT:: Kevin Gibson AUTHOR:: Kevin Gibson WE BUILD 1STt4e FS'V_iI.:A S ifS 0$JX4'fF: ix9`1RLO RESULTS SYSTEM/UNIT: SF -1 B-02 AREA: 1st Floor Unit Data Fan Manufacturer Fan Model Number Fan Serial Number Rated Airflow Capacity Twin City Fan DSI-150AE 118-000000261901 2300 CFM L/S Test Data Design Airflow Motor Volts T1-T2 Motor Amps T1 2300 CFM L/S 209 Volts Volts 9.6 @ 70% Amps Amis SF -1 B-02 Supply Outlet Summary Tested By: Kevin Gibson Date: 3/25/2019 Motor Data Motor Manufacturer Motor Frame Motor HP Motor RPM Motor Rated Volts Motor Phase Motor Hertz Motor FL Amps Motor Service Factor Baldor Direct Drive 2 HP HP 1800 RPM RPM 208-230 Volts Volts 1 60 Hz Hz 12.00 Amps Amps 1.00 System/Unit Area Served Outlet Type Size LxW / D Design Airflow Prelim Airflow % Prelim Diff. Final Airflow % Final Diff. Remark Outlet -01 Clean Room Clean Room DT5-Titus MCD 14/14 575 580 101 580 101 Clean Room Outlet -02 Clean Room Clean Room DT5-Titus MCD 14/14 575 620 108 621) 108 Located in Environme ntal Test/Recei vin] Outlet -03 Clean Room Clean Room DT5-Titus MCD 14/14 575 520 90 521) 90 key Outlet -04 Clean Room Clean Room DT5-Titus MCD 14/14 575 580 101 580 101 Totals: -- 2300 0 2300 0 100 0 2300 0 100 0 - SF -1B-02 Return Inlet Summary System/Unit Area Served Inlet Type Size LxW / D Design Airflow Prelim Airflow % Prelim Diff. Final Airflow % Final Diff. Remark RA Inlet -01 Clean Room Clean Room G2 -Titus 350FL AG- 15 20/20 2100 2100 100 2050 98 Clean Room RA Inlet -02* Clean Room Clean Room SWG 18/30 200 200 100 325 163 Located in Environme ntal Test/Recei vin] Totals: - - 2300 0 2300 0 100 0 - 103 0 - Log: SF -1 B-02/RA Inlet -02 4/15/2019 Kevin Gibson SF -1 B-02 Return Air #2 - located in Shaker Pit Extra air used to help pressurize the Clean Room Hermanson )Hermanson Fan Unit PROJECT: LEO STELLA TI LOCATION: Tukwila, WA PROJECT #: 21-18-13166 DATE: 4/15/2019 CONTACT: Kevin Gibson AUTHOR: Kevin Gibson WE BUILD TR -VA FSLATR;i'.1:F; RESULTS SYSTEM/UNIT: SF -1 B-03 AREA: 1st Floor Unit Data Fan Manufacturer Fan Model Number Fan Serial Number Rated Airflow Capacity Twin City Fan DSI-150AE 118-00000261902 2300 CFM L/S Test Data Design Airflow Actual Airflow Design RPM Motor Volts T1-T2 Motor Amps T1 2300 CFM US 2345 CFM L/S 1800 RPM RPM 209 Volts Volts 9.70 Amps Amps SF -1B-03 Supply Outlet Summary Tested By: Kevin Gibson Date: 3/25/2019 Motor Data Motor Manufacturer Motor Frame Motor HP Motor RPM Motor Rated Volts Motor Phase Motor Hertz Motor FL Amps Motor Service Factor Baldor Direct Drive 2 HP HP 1800 RPM RPM 208-230 Volts Volts 1 60 Hz Hz 12.00 Amps Amps 1.00 System/Unit Area Served Outlet Type Size LxW / D Design Airflow Prelim A rflow % Prelim Diff. Final Airflow % Final Diff. Remark Outlet -01 Clean Room Clean Room DT5-Titus MCD 14/14 575 580 101 580 101 Outlet -02 Clean Room Clean Room DT5-Titus MCD 14/14 575 590 103 590 103 key Outlet -03 Clean Room Clean Room DT5-Titus MCD 14/14 575 575 100 575 100 key Outlet -04 Clean Room Clean Room DT5-Titus MCD 14/14 575 600 104 600 104 Totals: - - 2300 0 2345 0 102 0 2345 0 102 0 - SF -1B-03 Return Inlet Summary System/Unit Area Served Inlet Type Size LxW 1 D Design Airflow Prelim Airflow % Prelim Diff. Final Airflow % Final Diff. Remark RA Inlet -01 Clean Room Clean Room G2 -Titus 350FL AG - 15 20/20 2100 2200 105 2200 105 RA Inlet -02 Clean Room Clean Room EC2-Titus 50F-8 24/24 200 200 100 200 100 key Totals: - - 2300 0 2400 0 104 0 - 104 0 - Hermanson )Hermanson Fan Unit PROJECT: LEO STELLA TI LOCATION: Tukwila, WA PROJECT #: 21-18-13166 DATE: 4/15/2019 CONTACT: Kevin Gibson AUTHOR: Kevin Gibson WE BUILD atauvIlu +RICI. RESULTS SYSTEM/UNIT: SF -1 B-04 AREA: 1st Floor Unit Data Fan Manufacturer Twin City Fan Fan Model Number DSI-150AE Fan Serial Number 118-00000261903 Rated Airflow Capacity 2300 CFM US Test Data Design Airflow Motor Volts T1-T2 2300 CFM L/S 209 Volts Volts SF -1B-04 Supply Outlet Summary Tested By: Kevin Gibson Date: 3/25/2019 Motor Data Motor Manufacturer Motor Frame Motor HP Motor RPM Motor Rated Volts Motor Phase Motor Hertz Motor FL Amps Motor Service Factor Baldor Direct Drive 2 HP HP 1800 RPM RPM 208-230 Volts Volts 1 60 Hz Hz 12.00 Amps Amps 1.00 System/Unit Area Served Outlet Type Size LxW / 0 Design Airflow Prelim Airflow % Prelim Diff. Final Airflow % Final Diff. Remark Outlet -01 Clean Room Clean Room DT5-Titus MCD 14/14 575 520 90 520 90 Outlet -02 Clean Room Clean Room DT5-Titus MCD 14/14 575 515 90 515 90 Outlet -03 Clean Room Clean Room DT5-Titus MCD 14/14 575 530 92 530 92 Outlet -04 Clean Room Clean Room DT5-Titus MCD 14/14 575 560 97 560 97 Totals: - - 2300 0 2125 0 92 0 2125 0 92 0 SF -1B-04 Return Inlet Summary System/Unit Area Served Inlet Type Size LxW / D Design Airflow Prelim Airflow % Prelim Diff. Final Airflow % Final Diff. Remark Inlet -01 Clean Room Clean Room G2 -Titus 350FL AG - 15 20 / 20" 2300 2325 101 2325 101 Totals: - - 2300 0 2325 0 101 0 - 101 0 Hermanson Hermarison Heat Pump PROJECT: LEO STELLA TI LOCATION: Tukwila, WA PROJECT #: 21-18-13166 Miii..14.16•19~140161•INORIS 0014•1 OM MIPOIMMIatil MOM. DATE: 4/15/2019 CONTACT: Kevin Gibson AUTHOR: Kevin Gibson P WE BUILD XR STtv$f1L+TKAS.0"5 7f: &0 P4SxikL0 RESULTS SYSTEM/UNIT: FCU -1B-101 AREA: Suite 1B Unit Data Unit Manufacturer Daikin Unit Model Number FXSQ48TAVJU Unit Serial Number E00182 Unit Discharge Horizontal FCU-1B-101/Filter Filter Manufacturer Filter Type Filter Qty - S1 Filter Size - 51 Flanders mery 8 pleat 2 10/25/2" Test Data Design Airflow Actual Airflow Design Outside Airflow Actual Outside Airflow Design Return Airflow Actual Return Airflow FCU-1B-101/Fan Motor Volts T1-T2 Motor Amps T1 1320 CFM US 1310 CFM US 0 CFM US 0 CFM L/S 1320 CFM L/S 1310 CFM L/S 209 Volts Volts 1.60 Amps Amps Log: Tested By: Kevin Gibson Date: 1/2/2019 Motor Data FCU-1B-101/Fan Motor Manufacturer Daikin Motor Frame Direct Drive Motor HP Not Listed HP HP Motor Rated Volts 208-230 Volts Volts Motor Phase 1 Motor Hertz 60 Hz Hz Motor FL Amps 2.0 Amps Amps FCU -1 B-101 1/2/2019 Kevin Gibson Email from Engineer for CFM. FCU -1 B-101 Supply Outlet Summary System/Unit Area Served Outlet Type Size LxW / D Design Airflow Prelim Airflow % Prelim Diff. Final Airflow % Final Diff. Remark Outlet -01 Bakeout Bakeout DT5-Titus MCD 14/14 330 310 94 330 100 key Outlet -02 Bakeout Bakeout DT5-Titus MCD 14/14 330 280 85 320 97 20% closed Outlet -03 Bakeout Bakeout DT5-Titus MCD 14/14 330 240 73 330 100 25% closed Outlet -04 Bakeout Bakeout DT5-Titus MCD 14/14 330 290 88 330 100 20% closed Totals: - - 1320 0 1120 0 85 0 1310 0 99 0 - Hermanson )Hermanson Heat Pump PROJECT: LEO STELLA TI LOCATION: Tukwila, WA PROJECT #: 21-18-13166 FCU -1B-101 Return Inlet Summary DATE:: 4/15/2019 CONTACT % Kevin Gibson AUTHOR: Kevin Gibson WE BUILD Og_LP,IP: P4Sti LO RESULTS System/Unit Area Served Inlet Type Size LxW / D Design Airflow Prelim Airflow % Prelim Diff. Final Airflow % Final Diff. Remark RA Inlet -01 Bakeout Bakeout EC2-Titus 50E-8 24/24 660 560 85 655 99 RA Inlet -02 Bakeout Bakeout EC2-Titus 50E-8 24/24 660 560 85 655 99 Totals: -- 1320 0 1120 0 85 0 - 99 0 - SYSTEM/UNIT: HP -1B-101 Unit Data Unit Manufacturer Unit Model Number Unit Serial Number Daikin RXTQ48TAVJU F003811 Tested By: Kevin Gibson Date: 11/26/2018 Hermanson )Hermanson Heat Pump PROJECT: LEO STELLA TI LOCATION: Tukwila, WA PROJECT #: 21-18-13166 DATE: 4/15/2019 CONTACT: Kevin Gibson AUTHOR: Kevin Gibson WE BUILD MATKS F. t.MT0,44.FS t*tt 'AREO RESULTS SYSTEM/UNIT: HP -G01- Condition 1- Shaker Pit Operation AREA: ENVIRON TEST Unit Data Unit Manufacturer Trane Unit Model Number WSC120H4RPA0300C1A206 010H0000D100000000 Unit Serial Number 183915918L Unit Discharge Horizontal HP -G01- Condition 1- Shaker Pit Operation/Filter Filter Manufacturer Filter Type Filter Qty - S1 Filter Size - S1 Flanders Mery 8 4 20x25x2 Test Data Design Airflow Actual Airflow Design Outside Airflow Actual Outside Airflow Design Return Airflow Actual Return Airflow HP -G01- Condition 1- Shaker Motor Volts T1-T2 Motor Volts T2-T3 Motor Volts T1-T3 Motor Amps T1 Motor Amps T2 Motor Amps T3 3725 CFM us 4035 CFM L/S 3725 CFM uS 3980 CFM L/S 0 CFM uS 55 CFM LIS Pit Operation/Fan 486 Volts Volts 486 Volts Volts 484 Volts Volts 1.40 Amps Amps 1.40 Amps Amps 1.40 Amps Amps Log: Tested By: Kevin Gibson Date: 4/15/2019 Motor Data HP -G01- Condition 1- Shaker Pit Operation/Fan Motor Manufacturer Trane Motor Frame Motor HP Motor RPM Motor Rated Volts Motor Phase Motor Hertz Motor FL Amps Not Listed 2.75 HP HP 1513 RPM RPM 460 Volts Volts 3 60 Hz Hz 3.60 Amps Amps HP -G01- Condition 1- Shaker Pit 3/25/2019 Operation Kevin Gibson HP -G01. Condition 1, Shaker Pit Exhaust Fan Operation. Trane controls - 4000 CFM Minimum airflow for Electric Heat Strips @ 54kw Shaker Pit EF, Interlock relay, automatically changes condition based on amp draw of EF. Hermanson Heat)Hermanson Pump PROJECT: LEO STELLA TI LOCATION: Tukwila, WA PROJECT #: 21-18-13166 HP-GO1- Condition 1- Shaker Pit Oiperation Supply Outlet Summary DATE: 4/15/2019 CONTACT: Kevin Gibson AUTHOR: Kevin Gibson WE BUILD System/Unit Area Served Outlet Type Size LxW / D Design Airflow Prelim Airflow % Prelim Diff. Final Airflow % Final Diff. Remark Ouuet-01 Equipment Test Equipment Test SM1 18/10 745 1100 148 805 108 North, Closed 40% 0uue+02 Equipment Test Equipment Test SM1 18/10 745 1050 141 815 109 Closed 35Y6 Outlet -03 Equipment Test Equipment Test SM1 18/10 745 1055 142 810 109 Center Key Outlet -04 Equipment Test Equipment Test SM1 1e/10 745 1080 145 805 108 Closed 40% Outlet -05 Equipment Test Equipment Test SM1 18/10 745 1100 148 800 107 South Closed 40% Totals: - - 3725 0 5385 0 14e 0 4035 0 108 0 - Hermanson )Hermanson Heat Pump PROJECT: LEO STELLA TI LOCATION: Tukwila, WA PROJECT #: 21-18-13166 DATE: 4/15/2019 CONTACT: Kevin Gibson AUTHOR: Kevin Gibson WE BUILD T7STIP. FSLAMJ SIDS tt OF1J4t : iglAREA RESULTS SYSTEM/UNIT: HP -G01- Condition 2 - Normal Operation AREA: ENVIRON TEST Unit Data Unit Manufacturer Trane Unit Model Number WSC120H4RPA0300C1A206 010H0000D100000000 Unit Serial Number 183915918L Unit Discharge Horizontal HP -G01- Condition 2 - Normal Operation/Filter Filter Manufacturer Flanders Filter Type Filter Qty - S1 Filter Size - S1 Mery 8 4 20x25x2 Test Data Design Airflow Actual Airflow 2230 CFM us 4035 CFM us Design Outside Airflow 90 CFM L/S Actual Outside Airflow 100 CFM L/S Actual Return Airflow 3935 CFM US HP -G01- Condition 2 - Normal Operation/Fan Motor Volts T1-T2 486 Volts Volts 486 Volts Volts 484 Volts Volts 1.40 Amps Amps 1.40 Amps Amps 1.40 Amps Amps Motor Volts T2-T3 Motor Volts T1-T3 Motor Amps T1 Motor Amps T2 Motor Amps T3 Log: Tested By: Kevin Gibson Date: 4/15/2019 Motor Data HP -G01- Condition 2 - Normal Operation/Fan Motor Manufacturer Trane Motor Frame Not Listed Motor HP 2.75 HP HP Motor RPM 1513 RPM RPM Motor Rated Volts 460 Volts Volts Motor Phase 3 Motor Hertz 60 Hz Hz Motor FL Amps 3.60 Amps Amps HP -G01- Condition 2 - Normal Operation 3/28/2019 Kevin Gibson HP -G01. Condition -2, Normal Operation. Trane controls - 4000 CFM Minimum airflow for Electric Heat Strips @ 54kw Hermanson )Hermanson Heat Pump PROJECT: LEO STELLA TI LOCATION: Tukwila, WA PROJECT #: 21-18-13166 HP -G01- Condition 2 - Normal Operation Supply Outlet Summary DATE: 4/15/2019 CONTACT: Kevin Gibson AUTHOR: Kevin Gibson WE BUILD g Ottiv0'1,451f10 RESULTS System/Unit Area Served Outlet Type Size LxW / D Design Airflow Prelim Airflow % Prelim DM. Final Airflow % Final Diff. Remark Outlet -01 Equipment Test Equipment Test SM1 18/10 445 1210 272 805 181 North - Closed 40% Outlet -02 Equipment Test Equipment Test SM1 18/10 445 960 216 815 183 closed 35% Outlet -03 Equipment Test Equipment Test SM1 18/10 445 980 220 810 182 Center - key Outlet -04 Equipment Test Equipment Test SM1 18/10 445 850 191 805 181 closed 40% Outlet -05 Equipment Test Equipment Test SM1 18/10 445 1420 319 80D 180 South - closed 40% Totals: - - 2225 0 5420 0 244 0 4035 0 181 0 - Hermanson illiermanson Balancing Equipment List: Kevin Gibson Job Number: Date: Equipment Manufacturer Model/Serial Number Calibration Date Capture Hood Evergreen Telemetry CH -15D / 1800224 7/10/2018 DP Manometer Testo 5101 / 49101556 9/19/2019 Amp Probe Fluke 902FC / 40230219W5 02/30/2018 Pressure / Velocity Module Evergreen Telemetry S -PVF -1 / 1600344 1/26/2018 Vane Anemometer Testo 4101 / 49008603 9/19/2018 Hydronic Manometer TSI HM685 / 71722223 8/15/2018 Ultrasonic Flow Meter General Electric Transport PT878 / 10237 Factory Vane Anemometer Testo 417 / 61053074 8/23/2018 Temperature Sensor Evergreen Telemetry PR -T-1 / 1700358 7/5/2018 Flow Hood Dwyer SAH -22 / 01FRDY 5/11/2018 Water Meter TSI 801290 / 71615117 10/18/2017 External Pipe Temperature Testo 1151/462010058 8/23/2018 External Pipe Temperature Testo 1151/462010071 8/23/2018 H/L Refrigerant Pressure Testo 5491/49291848 8/23/2018 H/L Refrigerant Pressure Testo 549i/49291852 8/23/2018 Manometer / Air Flow Meter Fluke 922/39660006 10/1/2017 Remarks: WE BUILD iM.Q.T#iG' & DELIVER INSPIRED RESULTS MECHANICAL ABBREVIATIONS 'et RI1.0.110. UAW CCM uue R/ Pa ISM rm. fKOR 6013 P.M. PAW MO INLVE Baa,LOR 9011. UKOS X. ARNIM aN. AT LOW AN ITYPFRAMRE pp pp= RC Mop MS KM. MD WON &F 119 SOT BORT. ORD SCA. / a<. asIWO MO WM Oda. Mrt WIN DCRA.1. PER C0... WATER OPPL MEW FUT KR learrE MC C11014 01 010m COS MOVE 03. 0..1/001KCIM/096111. CC. CON,MCIOR COOK =ROWE MCCING TO. CC.. 010 A.VCCRONSER mlp Car Cp. CCor9 Let COSCres enrct,51A5s V1111 MONK CM LARO WWI STEW WIC teaUm ea EWE r mnuA 11090,0 NOCE 1411.-L1 WA. CLOSED/KMa COCIEVAAHR eM°.,w/oma. PCMC1 P. MK MCI R11391. COW RAW CF 0.8SCOM KEMAL ALM Fp SOAK poi ROADS POR WARE 1611CAJOE MUM TOWED COME AA SM. EC MEMO wAm MT WO RMO ELNATION ELECALCIELKIROWCIICIRE DB PERM COW. PT DUNG IMF EriVw6NT ESP 9.9(1,11C PRESS. �Rfl On. rtu� cvn niE WPM 03.09, FO OWPOR Mk FRE KAMM [WM. FM. NM LW /NM NAT M FlW PRO.. KR Rm. rt ourta pa WIDOW 010. VOCE/uuu FETWNCE KO MKO ICKOMW RF F191 NETRUIRNS PLR WAS RCRIOAAri SAT. MECHANICAL LEGEND SURFti NR ba,y.p j 101 DUCT .n n - w/1910 oKT ox/ MAY MOM DUCT - DR/ MAT cuct maw. a.rtA mag • aUml .6111. NNW /sunna CA9 WORM SOW OM. MI ROY MEnw COUR WM MOWED aww POW DUCT SPRIWNW MN as AMMO QMKT GCS PMSN. MOOR nnu(PIM MEM rein • KM1 OF KOWTOWCal z sit i7.•••. W ODA. pm SSOCK IAM O= 00714 OUR.< tE21 TOO WM. I -MWED m•IE 1K WM WC OR UP REMCRE .18.1 9.9911.1, n-wAs/cum-i OBE, RATER . CB us MECHANICAL GENERAL NOTES 14" 6ri .6.4. 091940, MINO1 UM m n< ms m ma.m. Ars t" CRAW, x A semis`a m"""°w.w""s", '"'U«Urz iaame.m� 4 KM MIK 0,0106. MOSONS CEDB, EX PIMP 00WER OF MR 0....6S PRI. TO PRCOORC os aw. v VO a"iwvmc. •oma on - Kr MASS C. KOMI MSS. MIK. OOPS.. CS V/ IRCX 164u. EX) TO COMMOC110,1 S1A.POS 1. SLY MASS A OXT FISM N ANS FP... TO KU CONTRUCTIOR STMOMOS11111... 0.06S 1 Al OW. OVNIKK Lo_rsS *MO MM. MR Iwo wee C au1 !,11,11.4%;1"..L.," sACr RAMC =n LOOS. ST. 9.1 903 MO K PRCCBM.L. LBERIKT Kt MIS KR KEA 0169CaRMOR ALL FARCV*.u.S1. ER PRCCLAIR- Ki.ArS VALK MY. 10 Of One, M5E &airs.M.T rl'a. W:"s 'a ". a. ava. KAFUSMO( sa. o. PAES .a..•« RECUROI a. ma. COMOMNOTITOT42= 4771 WORED"Pin= Mr aMTURk.,. rSS P.LS 9.111.4*, .0,39.1.01 Bra AT ALL COCE., MLR,. MO MICE IRCAIMNS x'm"orn1v¢ 0NOI,J mw �r<.W.ESsw a nasmamx" wT1.19 OVA: safSSY-";a F P ns farm-- ru,-hczsagromirgure. ..ow,..,a.-..a- MINIMUM DUCT INSULATION MINIMUM PIPE INSULATION WOI VIM L� sL M �„ 1 f „ DRAWING INDEX LEGAL DESCRIPTION REPUT TOR LOTS IMO 5 ES 11.1M 32 NOK 15, PORTO LOIS 019,MCE NO !SR WCOOK NO MODIUM3207 LY 10,01 VICINITY MAP NO SOLE V/ IT SITEMAP .o s*x/ Hermanson LEO STELLA TI Renswns Design Teas COVER SHEET HVAC CI U M0.00 ISSUE FOR PERMIT VRF INR UNIT SCHEDULE FILTER PACKAGE SCHEDULE I n XSiiri'#ir' anson a Oftlf. se IMO VRF 0 O UNIT SCHEDULE eseSesiw.va .3..w —SA TERMINAL UNIT SCHEDULE • ELECTRIC moa_Ht.. MODULAR DIF FUSER SCHEDULE ,. TRANSFER RETURN EXHAUST AIR GRILLES w. ....o .#F31 .. PIPPAR it *"Time ._ .n..�..r,.� rd v.. r:#UXIN". Nix # © r MC IMINMMINISMSOMB WWII it =xv ;; L [lit Se IserseaNk VIMMelal .11400. waIMOmemos... some tovnmrunV��auwr<x+.SMILMOMMOMMTreasemerssana Wee m..x MUMMIS imc110,111.0nirs .�.�npi'n mrnwaerPrvrrxs .avx.w.ro MIMI ars. SUMi Mar milimmeossimssante MM. Me. MOMS Sine seoloMemla seam. me R SCHEDULE ..m., ;_... _ AriAVAZo ""r FtYwriSa� �ir c�.,rsn�cr: arar.,r� uw+n �u± • mommonneemommursiansmom IttimarrAIVIVILNIFAV'' Nor Nommw,-tiFexwonwrxt wftw.mi mrxxxxxxonstnnmi 11~1101XXIMMIMOIll #1i##rnme•011r=rrOffrMAILVPI �rnr_ N#r?# e sira.##ri���rr. Besinra MIX •=iMIIIEXXIM111XXIIi7XXXXXI,OX LEO STELLA TI Urn rie"' RevXam terrearesee a. semenia.imi.St wv�eamwvreM wvww�swrc iaxps�.iMnrcnip+. .w. n[pies.orse mesem,rnnwr Chis%MM. ete MO. MM." Meal Mos teas Meer FAN SCHEDULE xxxxxxrrn�awiay.ruwiw;irxww.meowss .r<.e a"°" n.r.Imno...w ourroc.m.. t....everammesse Ms. sacelaiMOMea mem. mamas mama cemmos rnaq.arw:�'�O.a.eo i.®w `rY°tWXfaseF &spa••..sem rn.umn wa.erea PACKAGED GROUND MOUNTED HEAT PUMP UWT SCHEDULE DX pr, Team seams- SASS! FIRP4MIS SCHEDULE SHEET • HVAC M0.01 ISSUE FOR PERMIT 1ST FLOOR DEMO PLAN - HVAC Rerream g manson + LEO STELLA TI Renzmns Des, Team 1ST FLOOR DEMO PLAN HVAC M2.01 D ISSUE FOR PERMIT 1ST FLOOR PLAN - HVAC 4)� ansae u'"'` LAp.r 1 s i` S • Hermanson LEO STELLA TI wok Ivy s ROMA Is NISI Da Design Team 1ST FLOOR PLAN HVAC M2.01 ISSUE FOR PERMIT 1ST FLOOR PIPING PLAN - HVAC SHEET ADDEO TO SET Hermanson LEO STELLA TI MOSES WA 98164 Revis ons Design Team FOR GIEVEESE 1ST FLOOR PIPING PLAN HVAC M P2.01 ISSUE FOR PERMIT SHEET ADDED TO SET ) ROOF PIPING PLAN - HVAC 1 Hermanson 1.1 roolmy. OslIn. Tamen.. LEO STELLA TI awl®: Revisions Ama se Design Team 3• SORG, US ROOF PIPING PLAN -HVAC MP2.R1 ISSUE FOR PERMIT l (l RETURN AIR BOOT DETAIL (ABOVE CEILING) ALF 10 EVA T (1 RETURN AIR 500T DETAIL I I, 1 ,27 TYPICAL DUCT FITTINGS I. USA VLF ASSAM MO (1 LAY -IN DIFFUSER WI DUCT DROP 7 IIIIIIHIII1 (1 SUPPLY AIR DIFFUSER DETAIL MEM I (\ SOUND WALL DUCT PENETRATION DETAIL vwn.r.ae.o.avxw.w .w.a.�rwc.uawa.n�e [CEILING PLENUM LAYOUT (.1 FILTRATION UNIT DETAIL 0 Zff4 0 0 0 0 0 0 <0 n VAV CLEARANCE DETAIL 0 ,0 �.ot'ucw 0 -TYPICAL IN-LINE FAN DETAIL ••••••••1011 TYPICAL TERMINAL UNIT - FAN POWERED FOP CU ,LISE Her son LEO STELLA TI TAM. AN wee Rev on _tea n .w�m�l Design Team DEAL SHEE1 - HVAC M5.01 ISSUE FOR PERMIT July 30, 2018 City of Tukwila Department of Community Development KAYLENE NELSON 1221 SECOND AVE N KENT, WA 98032 RE: Correction Letter # 1 PLUMBING/GAS PIPING Permit Application Number PG18-0097 LEO STELLA - 12501 E MARGINAL WAY S Dear KAYLENE NELSON, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING - PG DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these com ments. • (GENERAL INFORMATION NOTE) PLAN SUBMITTALS: (Min. size 11x17 to a preferably maximum size of 24x36; all sheets shall be the same size; larger sizes may be negotiable. "New revised" plan sheets shall be the same size sheets as those previously submitted.) "STAMP AND SIGNATURES" (If applicable) For Engineers: "Every page of a plan set must contain the seal/stamp, signature of the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature. Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp, signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a bound specification document that contains specifications other than that of an engineering or land surveying nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is responsible." It shall not be required to have each page of "specifications" (calculations) to be stamped and signed; Front page only will be sufficient (WAC 196-23-010 & 196-23-020). Architects: "date" only not required (WAC 308-12-081.). (BUILDING REVIEW NOTES) 1. The proposed Sure Seal SS2009V trap seal shall not be allowed. Floor sinks and floor drains up stream of the main sewer line shall have trap seal primers. No form of trap that depends for its seal upon the action of movable parts shall be used. Show trap primers for each floor drain. Trap primers shall also be located where they can be maintained. Provide manufactures specifications for the trap primers. (UPC 1004.1, 1005.0 & 1007.00) Note: Contingent on response to these corrections, further plan review may request for additional corrections. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 Sincerely, e le ' ply Permit Technician File Na. PGI8-0097 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 \ /1 PLAN REVIEW/ROUTIN G SLIP PERMIT NUMBER: PG18-0097 DATE: 12/10/18 PROJECT NAME: LEO STELLA SITE ADDRESS: 12501 E MARGINAL WAY S Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued X Revision # 1 after Permit Issued DEPARTMENTS: AT M P;; - Building Division Public Works Fire Prevention Planning Division Structural Permit Coordinator IN PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 12/11/18 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Ty] Corrections Required (corrections entered in Reviews) Approved with Conditions Denied (ie: Zoning Issues) DUE DATE: 1/08/19 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg Fire 0 Ping PW Staff Initials: 12/18/2013 'ERMIT COORD COPY Y, PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG18-0097 DATE: 08/14/18 PROJECT NAME: LEO STELLA SITE ADDRESS: 12501 E MARGINAL WAY S Original Plan Submittal X Response to Correction Letter # Revision # Revision # before Permit Issued after Permit Issued DEPARTMENTS: 111 \tv� qq V i.\iilding Division Public Works El Fire Prevention Structural Fl PRELIMINARY REVIEW: Not Applicable C (no approval/review required) Planning Division Permit Coordinator DATE: 08/16/18 Structural Review Required REVIEWER'S INITIALS: DATE: C APPROVALS OR CORRECTIONS: Approved Approved with Conditions Corrections Required (corrections entered in Reviews) Denied (ie: Zoning Issues DUE DATE: 09/13/18 C Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: 12/18/201) P�RIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG18-0097 DATE: 07/19/18 PROJECT NAME: LEO STELLA SITE ADDRESS: 12501 E MARGINAL WAY S X Original Plan Submittal Response to Correction Letter # Revision # Revision # before Permit Issued after Permit Issued DEPARTMENTS: c4— Building Division Fire Prevention ❑ Planning Division i I' 4 ►(6 Public Works Structural Permit Coordinator 01 E46 PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 07/24/18 Structural Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: DUE DATE: 08/21/18 Approved ri Approved with Conditions n Corrections Required n Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only 11/70V CORRECTION LETTER MAILED: Departments issued corrections: Bldg LES Fire 0 Ping ❑ PW ❑ Staff Initials: 12/18/2013 PROJECT NAME: SITE ADDRESS: I25-() fit -p,,( LithS PERMIT NO: .?61e— OOR7 ORIGINAL ISSUE DATE: q-11— [ �j REVISION LOG REVISION NO. DATE RECEI'VED STAFF INITI LS ISSUED DATE STAFF INITIALS W' rod S S i Summary of Revision: l,h tvk 4) 1 4,474.vvdrNS , Received by: [LArL ' ti____, REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) City of Tukwila REVISION SUBMITTAL Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http:tfwww.TukwilaWA.gov Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: Plan Check/Permit Number: &' ▪ Response Response to Incomplete Letter # 1:1 Response to Correction Letter ▪ Revision # after Permit is Issued Ei Revision requested by a City Building Inspector or Plans Examiner LI Deferred Submittal # Project Name: L?n Project Address:\2'S() (A)(k.ii s.c Contact Person: y cal u, Cl\A Phone Number: 2-3 - 2Si 71 Summary of Revision: C,V\ CA -no) 'N Wiu I WO- houtei K&Th ho _tic/ v7rYhS. CITY OF TUKWILA DEC 14 2018 PERMIT CENTER Sheet Number(s): "Cloud" or highlight all areas of revision including date of Fisio (i() Received at the City of Tukwila Permit Center by: '—Entered in TRAKiT on --1 V/ \Permit CenterkiemplatesTordis \Revision Submittal Form doc Revised' August 2015 / City 'uf Tukwila REVISION SUBMITTAL Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: August 7, 2018 Plan Cheek/Pennit Number: PG18-0097 LJ Response to Incomplete Letter # LA Response to Correction Letter # 1 1] Revision # after Permit is Issued 11 Revision requested by a City Building Inspector or Plans Examiner EI Deferred Submittal # Project Name: LEO STELLA RECEIVED CITY OF TUKWILk AUG 09 2018 PERMIT CENTEf Project Address: 12501 E MARGINAL WAY S Contact Person: Kaylene Nelson Phone Number: 253-359-7147 Summary of Revision: Building Review Note 1: Trap primer connections will be provided at all FD -1 FFD -1 floor drain locations. Note that connection will not be provide at shower drains. Sheet Number(s): "Cloud" or highlight all areas of revision including date o revision Received at the City of Tukwila Permit Center by: Bi Entered in TRAKiT on VV: Permit Center (Brenda)TormaTermit Center Documents (Word)\Revi:iion Submittal Form doe Revised: August 2015 Non -Residential Sewer" 'se Certification Sewage Treatment Capacity Charge King County Department of Natural Resources and Parks Wastewater Treatment Division To be completed for all new sewer connections, reconnections or change of use of existing connections. Please Print or Type 12 �t1� nV/1(T;10CA. Property Street Address i .cO (CA %�� 1-1 .Q . tf Owner's Name 3 c7 3 (7 C2�' Owner's Mailing Address City For King County Use Only Account # No. of RCEs Monthly Rate La) itcP- State ZIP Ci S e* wDI State ZIP Owner's Phone Number including Area Code Property Contact Phone Number including Area Code Party to be Billed (if different from owner) Address City State ZIP A. Fixture Units Fixture Units x Number of Fixtures = Total Fixture Units Kind of Fixture Fixture Units No. of Fixtures Total Fixture Units Public Private Public Private Bathtub and Shower 4 4 I -- -Shower, Shower, per head 2 2 `Dishwasher 2 2 1 'L Drinking fountain (each head) 1 .5 Hose bibb (interior) 2.5 2.5 Clothes washer or laundry tub 4 2 Sink, bar or lavatory 2 1 I I Sink, Clinic flushing 8 8 Sink, kitchen 3 2 T.,- jSink, Sink,other (service) 3 1.5 Sink, wash fountain, circle spray 4 3 Urinal, flush valve, 1 GPF 5 2 Urinal, flush valve, >1 GPF 6 2 Water closet, tank or valve, 1.6 GPF 6 3 Water closet, tank or valve, >1.6 GPF 8 4 Total Fixture Units Residential Customer Equivalent (RCE) 20 fixture units equal 1.0 RCE Total Fixture Units = 20 ` RCE Property Tax ID # Subdivision Name Subdiv. # Building Name (if applicable) City or Sewer District _ Date of Connection Side Sewer Permit # Lot # Block # Please report any demolitions of pre-existing structures on this property. Credit for a demolition may be given under some circumstances. (See King County Code 28.84.050, 0.5) Demolition of pre-existing structure? ❑ Yes ❑ No Was structure on Sanitary Sewer? ❑ Yes ❑ No Was Sewer connected before 2/1/90? ❑ Yes ❑ No Sewer disconnect date Type of structure demolished Request to apply demolition credit to multiple structures? ❑ Yes ❑ No B. Other Wastewater Flow (in addition to Fixture Units identifiecRECE Type of Facility/Process: CITY OF TS JUL 19 2018 Estimated Wastewater Discharge: Gallons/daVERMIT CENTER Residential Customer Equivalents (RCE): 187 gallons per day equals 1.0 RCE Total Discharge (gaVday) _ 187 RCE C. Total Residential Customer Equivalents: (add A & B) A +B (a 5 cos Total RCE Pursuant to King County Code 28.84.050, all sewer customers who establish a new service which uses metropolitan sewage facilities shall be subject to a capacity charge. The amount of the charge is established annually by the Metropolitan King County Council at a rate per month, per residential customer or residential customer equivalent, for a period of fifteen years. The purpose of the charge is to recover costs of providing sewage treatment capacity for new sewer customers. All future billings can be prepaid at a discounted amount. Questions regarding the capacity charge or this form should be referred to King County's Wastewater Treatment Division at 206-477-5516. I understand that the information given is correct. I understand that the capacity charge levied will be based on this information. I understand that ny 9 tion may result in a revised capacity charge. Signature of Owner/Representative Date Print Name of Owner/Representative � (12,1r\L tJe �SCy--\ 1610_6969w_nonres_sewer_cap_chg_1058.indd White — King County Yellow — Local Sewer Agency Pink — Sewer Customer (Rev. 10/16) ®� HERMANSON COMPANY LLP t -- Washington State Department of Labor & Industries ionic Espanol Contact Safety & Health Claims & Insurance fl Search L&I Page 1 of 3 A -Z Index Help My Led Workplace Rights Trades & Licensing HERMANSON COMPANY LLP Owner or tradesperson Principals NICOLAISEN, KNUT H, PARTNER/MEMBER BROCK, DANIEL L, PARTNER/MEMBER FOX, DEAN M, PARTNER/MEMBER HENGEL, STEPHEN A, PARTNER/MEMBER DYCKMAN, KENNETH A, PARTNER/MEMBER ROBINETT, PAUL J, PARTNER/MEMBER HERMANSON, RICHARD L, PARTNER/MEMBER ALMON, KEVIN, PARTNER/MEMBER (End: 08/05/2010) MACDONALD, JAMES, PARTNER/MEMBER (End: 08/05/2010) Doing business as HERMANSON COMPANY LLP WA UBI No, 602 004 844 1221 2ND AVE N KENT, WA 98032-2945 206-575-9700 KING County Business type Limited Liability Partnership Governing persons CORP HERMANSON LLC HERMANSON GROUP; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no, HERMACLOO5BJ Effective — expiration 01/11/2000— 08/25/2020 Bond WESTERN SURETY CO Bond account no. 929381801 Active. Meets current requirements. $12,000.00 Received by L&I Effective date 12/01/2005 01/01/2006 Expiration date Until Canceled Help us improve https://secureini.wa.gov/verify/Detail.aspx?UBI=602004844&LIC=HERMACLOOSBJ&SAW= 9/17/2018 HERMANSON COMPANY LLP Insurance Transportation Ins Co Policy no. 6043050846 $1,000,000.00 Received by L&I Effective date 08/16/2018 08/21/2018 Expiration date 08/21/2019 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workerscomp premiums. L&I Account ID 409,648:01. Doing business as HERMANSON COMPANY LLP Estimated workers reported Quarter 2 of Year 2018 "Greater than 100 Workers" L&I account contact T4 / TERRI MADISON (360)902.4654 - Email: KIRT235@lni.wa.gov Account is current. Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 03/05/2018 Inspection no. 317948149 Location 635 Park Ave N Renton, WA 98057 Inspection results date 02/23/2016 Inspection no. 317939295 Location 15580 NE 31st St. Redmond, WA 98052 Inspection results date 05/21/2015 Inspection no. 317935231 No violations No violations No violations Page 2 of 3 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602004844&LIC=HERMACLOO5BJ&SAW= 9/17/2018 HERMANSON COMPANY LLP r Location 4480 154th PI NE Redmond, WA 98052 Inspection results date 12/10/2014 Inspection no. 317424935 Location 21601 76th Ave W. Edmonds, WA 98026 Inspection results date 05/17/2013 Inspection no. 316772151 Location 955 Broadway Tacoma, WA 98402 No violations Violations Page 3 of 3 Washington State Dept. of Labor 8 Industries. Use of this site ss subject to the laws of the slate of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602004844&LIC=HERMACL005BJ&SAW= 9/17/201.8 A AAV ABS ABV AC AD AD'L D/ADD ADJ AFF AFG AP ARCH ASME ATM BHP BLDG BOT BS BTU BTUH COND CCA TO C CBP CFFT CFM CI CLG CMU CO CO2 CL CONC COND CONN CONT CONTR COORD CPCT CW DDCA DEG DIA DIFF DISCH DN DOM DR DS DWG WV EA EFF L EL EC/ELECT ENT EQUIP ESW Er EWC EVVT EXIST/(E) EXP EXT FA FD FDN FF FIC FFD FLRX FOFPFPM FPS FSWH FT GALV GA/GAL GDC GEN GND GPH HBM HD HDHGR HOAIZ HP HR HT HW HWC HX HZ A BC CW E N WG NSUL PLUMBING / PIPING ABBREVIATIONS AIR/COMPRESSED AIR AIR ADMITTANCE VALVE ACRYLONITRITE BUTADIENE STYRENE ABOVE AIR COMPRESSOR ACCESS DOOR/AREA DRAIN/AIR DRYER ADDITION ADDITIONAL ADJACENT/ADJUST/ADJUSTABLE/ADJUSTMENT ABOVE FINISHED FLOOR ABOVE FINISHED GRADE ACCESS PANEL ARCHITECT AMERICAN SOCIETY OF MECHANICAL ENGINEERS ATMOSPHERE ATMOSPHERIC BRAKE HORSEPOWER/BOILER HORSEPOWER BUILDING BOTTOM OF PIPE BOTTOM BLACK STEEL BRITISH THERMAL UNIT BRITISH THERMAL UNITS PER HOUR CONDENSATE COMPRESSED AIR CENTER TO CENTER CAPACITY/END CAP CATCH BASIN CENTRIFUGE CENTRIFUGAL CAP FOR FUTURE CUBIC FEET PER MINUTE CAST IRON CEILING CONCRETE MASONRY UNIT CLEANOUT/COMPANY/CARBON MONOXIDE CARBON DIOXIDE COLUMN CONCRETE CONDENSATE CONNECT/CONNECTED/CONNECTION CONTINUOUS/CONTINUATION CONTRACTOR COORDINATE CHLORINATED POLYVINYL CHLORIDE COOLING TOWER CUBIC/COPPER/CONDENSING UNIT DOMESTIC COLD WATER DOUBLE CHECK VALVE ASSEMBLY DIRECT DIGITAL CONTROL DEGREE DEGREES DEIONIZED WATER DIAMETER DIFFERENTIAL/DIFFERENCE/DELTA DISCHARGE DOWN DOMESTIC DRAIN DOWNSPOUT DRAWING DRAIN, WASTE AND VENT EACH EFFICIENCY ELEVATION ELECTRICAL/ELECTRIC EMERGENCY ENTERING EQUIPMENT ELECTRIC RESISTANCE WELDED EMERGENCY SHOWER EXPANSION TANK ELECTRIC WATER COOLER/ EVAPORATIVE WATER COOLER ENTERING WATER TEMPERATURE EXISTING EXPANSION EXPOSED/EXPLOSION PROOF EXTERNAL ERIOR FAHRENH IT FEED/FILTER FACE AREA FIRE ALARM FLOOR CL N OUT FLOOR DRAIN FOUNDATION FINISH FLOOR FUNNEL FLOOR DRAIN FURNISHED AND INSTALLED BY CONTRACTOR FURNISHED AND INSTALLED BY OWNER FLEXIBLE FLOOR FURNISHED BY OWNER INSTALLED BY OTHERS FREEZE PROOF/FIRE PROTECTION FEET PER MINUTE FEET PER SECOND FREEZE PROOF WALL HYDRANT FLOOR SINK, FLOW SWITCH FOOT/FEET GALLON GALVANIZED GARAGE DRAIN/GARBAGE DISPOSAL GENERAL CONTRACTOR GENERAL GROUND GALLONS PER HOUR GALLONS PER MINUTE HOSE BIBB HEAD HEADER MERCURY HORIZONTAL HAND -OFF -AUTOMATIC HORSEPOWER HOUR HEIGHT/HEAT TRACE DOMESTIC HOT WATER DOMESTIC HOT WATER CIRCULATING HEAT EXCHANGER HERTZ INSTRUMENT AIR INTERNATIONAL BUILDING CODE INDUSTRIAL COLD WATER INSIDE DIAMETER/DIMENSION INVERT ELEVATION INCH/INCHES INCHES WATER GAUGE INSULATE/INSULATION INV IRW IW KWH KEC LAV LB/LBS LB/HR LPG LPS LWr MAX MH MCA MFRH MIN MISC MM MPS MTD NA NG NNIC NO NO2 NOM NP NTS 02 OC ODP ORD OVHD PD PERF PH PLBG POC PRESS PRV PS PSF PSI PSIG PVC RTM RCVR RD RECIRC RE REF RLG RPBP RPM RS RV RVD SAN SDT S_C SECT SO SOL SOLV SP SPEC SQ SQFT STRUC SUCT TBD TO TEMP THERM TPP TPS GP UNO UPC UR UTIL V VA VAC VB VEL VERT VOL VR VTR W/ W WAG WC WH WLD WM WO WP WR WWP INVERT IRRIGATION WATER INDIRECT WASTE KILOWATT HOUR KITCHEN EQUIPMENT CONTRACTOR LAVATORY POUND/POUNDS POUNDS PER HOUR LIQUID PROPANE GAS LOW PRESSURE STEAM LEAVING WATER TEMPERATURE MAXIMUM 1000 BRITISH THERMAL UNITS PER HOUR MINIMUM CIRCUIT AAPACITY MECHANICAL MANUFACTURER MINIMUM/ MINUTE MISCELLANEOUS MILLIMETERS MEDIUM PRESSURE STEAM MOUNTED NITROGEN NOT APPLICABLE NORMALLY CLOSED/ NOISE CRITERIA NATURAL GAS NOT IN CONTRACT NORMALLY OPEN/ NUMBER NITROUS OXIDE NOMINAL NON -POTABLE NOT TO SCALE OXYGEN ON CENTER OUTSIDE DIAMETER/DIMENSION/ OVERFLOW DRAIN OPEN DRIPPROOF OVERFLOW ROOF DRAIN OVERHEAD PRESSURE DROP/ PIT DRAIN/ PUMP DISCHARGE PERFORATED PHASE PLUMBING POINT OF CONNECTION PRESSURE PRESSURE REDUCING VALVE PRESSURE SWITCH POUNDS PER SQUARE FOOT POUNDS PER SQUARE INCH POUNDS PER SQUARE INCH GAUGE POLYVINYL CHLORIDE QUANTITY RISER RETURN RECEIVER ROOF DRAIN/ REFRIGERANT DISCHARGE RECIRCULATING/ RECIRCULATE REDUCE/ REDUCING REFERENCE REGULATOR RAIN LEADER/ REFRIGERANT LIQUID REDUCED PRESSURE BACKFLOW PREVENTER REVOLUTIONS PER MINUTE REFRIGERANT SUCTION RELIEF VALVE RELIEF VALVE DISCHARGE SOIL/ SUPPLY SANITARY SATURATION STORM DRAIN SEATTLE __ CODE SECTION SCREENED OPENING SOLENOID SOLENOID VALVE STATIC PRESSURE/ SPRINKLER SPECIFICATION SQUARE SQUARE FEET SANITARY SEWER STRUCTURAL SUCTION TO BE DETERMINED TEMPERATURE DIFFERENTIAL TEMPERATURE TEMPORARY THERMOMETER TOP OF PIPE TRAP PRIMER TRAP SEAL TYPICAL UNDERGROUND UNLESS NOTED OTHERWISE UNIFORM PLUMBING CODE URINAL UTILITY VENT/ VOLT VALVE/ VOLT AMPERE VACUUM AIR VOLTS ALTERNATINGCURRENT/ VACUUM VACUUM BREAKER VELOCITY/ VERIFY EXACT LOCATION VERTICAL VOLUME VENT RISER VENT THROUGH ROOF WASTE/ WIDTH/ WATT WITH WITHOUT WASTE ANESTHESIA GAS DISPOSAL WATER CLOSET WALL CLEANOUT WALL HYDRANT/ WATER HEATER/ WATT HOUR WELDED WATER METER WASTE OIL WATERPROOF/ WEATHERPROOF WASTE RISER WATERTIGHT/ WEIGHT WORKING WATER PRESSURE PLUMBING / PIPING LEGEND o ELBOW UP ELBOW DN DIRECTION OF FLOW DIRECTION OF SLOPE DOWN REDUCER TEE OUTLET UP TEE OUTLET DOWN UNION PIPE ANCHOR EXPANSION JOINT STRAINER WITH BLOWDOWN VALVE GATE VALVE GLOBE VALVE BALL VALVE CHECK VALVE PRESSURE REDUCING VALVE FLOW BALANCING VALVE (AUTO OR MANUAL) T&P RELIEF VALVE GAS COCK LINE CLEANOUT PRESSURE GAUGE WITH GAUGE COCK THERMOMETER FLEXIBLE CONNECTION PLUG OR CAP WATER HAMMER ARRESTOR BUTTERFLY VALVE SOLENOID VALVE BACKFLOW PREVENTER REDUCED PRESSURE BACKFLOW PREVENTER ti D�4 I►> I I l> I> IMETERI T GRIN SD OSD -NPCW /NPHW DI WAGD CA CO2 N2 NO2 02 MA MV MPS(#) MPR(#) LPs(#) LPR(#) COND 40 0 S EWH-1 C METER P&T PORT EXISTING PIPING DEMO PIPING WASTE VENT DOMESTIC HOT WATER -RECIRCULATING DOMESTIC HOT WATER DOMESTIC COLD WATER GREASE WASTE STORM DRAIN OVERFLOW STORM DRAIN NON -POTABLE COLD/HOT WATER DEIONIZED WATER WASTE ANESTHESIA GAS DISPOSAL COMPRESSED AIR CARBON DIOXIDE NITROGEN NITROUS OXIDE OXYGEN MEDICAL AIR MEDICAL VACUUM MEDIUM PRESSURE STEAM SUPPLY MEDIUM PRESSURE STEAM CONDENSATE RETURN LOW PRESSURE STEAM SUPPLY LOW PRESSURE STEAM CONDENSATE RETURN CONDENSATE FLOOR CLEANOUT FLOOR DRAIN / SINK PUMP ROOF DRAIN OR OVERFLOW DRAIN PLUMBING FIXTURES PLUMBING FIXTURE DESIGNATION POINT OF CONNECTION RISER DESIGNATION PLUMBING EQUIPMENT DESIGNATION DRAWING (CIRCLE NOTE) REFERENCE PLUMBING / PIPING GENERAL NOTES 1. ALL WORK SHALL CONFORM TO ALL APPLICABLE CODES AND REGULATIONS, INCLUDING, BUT NOT LIMITED TO THE 2015 IBC, 2015 UPC, 2015 WSEC, 2015 IMC, & SIMILAR YEAR WAC 296-104 BOILER RULES. 2. PLUMBING WORK CONSISTS OF WORK SHOWN ON DRAWINGS, DETAILS & DIAGRAMS. THE WORK INCLUDES FURNISHING, INSTALLING, SYSTEM INTEGRATION, TESTING, AND ASSURING PERFORMANCE OF THE SYSTEMS IN ACCORDANCE WITH REQUIREMENTS. THE WORK MAY INCLUDE ELECTRICAL AND ELECTRONIC COMPONENTS AS DESCRIBED IN THE CONTRACT DOCUMENTS. 3. VERIFY SYSTEM AND PERFORMANCE REQUIREMENTS TO ENSURE SYSTEM OPERATES AS DESIGNED. 4. LOCATION AND DETAIL OF ALL EQUIPMENT AND EQUIPMENT CONNECTIONS ARE APPROXIMATE. COORDINATE FINAL EQUIPMENT AND ARRANGEMENT AND INSTALL IN ACCORDANCE WITH OTHER TRADES' APPROVED SUBMITTALS AND DETAIL DRAWINGS AS APPLICABLE. 5. PROVIDE SUPPORTS FABRICATED FROM STEEL MEMBERS FOR INSTALLATION OF EQUIPMENT AS REQUIRED BY EQUIPMENT MANUFACTURER'S INSTALLATION INSTRUCTIONS OR AS SHOWN ON THE DRAWINGS. REQUIRED STRUCTURAL MEMBERS, BOLTS, AND WELDS SHALL BE IN ACCORDANCE WITH THE LATEST AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC) MANUAL. 6. PROVIDE ANCHOR BOLTS OF THE SIZE, TYPE, AND LENGTH RECOMMENDED BY THE EQUIPMENT MANUFACTURER, AS REQUIRED BY EQUIPMENT MANUFACTURER'S INSTALLATION INSTRUCTIONS OR AS SHOWN ON THE DRAWINGS. 7. PROVIDE SUPPORTS AND SEISMIC RESTRAINTS FOR PIPES AND EQUIPMENT AS SPECIFIED OR AS SHOWN ON THE DRAWINGS. IF REQUIRED FOR INSTALLATION, PROVIDE ADDITIONAL STRUCTURAL MEMBERS BETWEEN COLUMNS, JOISTS, AND STRUCTURAL FRAMES TO MEET THE SUPPORT REACTIONS (FORCES, MOMENTS, DEFLECTIONS). STRUCTURAL MEMBERS SHALL BE DESIGNED BY A REGISTERED PROFESSIONAL ENGINEER AND INSTALLED BY G.C. WIRES FOR CEILING SYSTEM, ETC... SHALL NOT BE HUNG FROM PLUMBING EQUIPMENT OR PIPING SUPPORTS. 8. DO NOT CORE DRILL OR DRILL THROUGH BEAMS, COLUMNS, AND SHEAR WALLS UNLESS SHOWN ON THE STRUCTURAL DRAWINGS OR APPROVED BY THE STRUCTURAL ENGINEER. 9. REFER TO ARCHITECTURAL DRAWINGS FOR LOCATION OF CEILING OR SURFACE MOUNTED DEVICES. INSTALL EQUIPMENT IN CONFORMANCE WITH ARCHITECTURAL FEATURES IN THE CENTER OF CEILING TILES, IN THE CENTER OF ROOMS, OR WHERE SHOWN ON ARCHITECTURAL DRAWINGS. WHERE EQUIPMENT IS NOT SHOWN ON ARCHITECTURAL PLANS, OBTAIN DIRECTION FROM THE ARCHITECT PRIOR TO INSTALLATION. 10. COORDINATE ROOF CURB AND FLASHING REQUIREMENTS WITH ARCHITECTURAL PLANS. 11. ROOM NAMES AND NUMBERS ARE FOR REFERENCE ONLY. REFER TO ARCHITECTURAL DRAWINGS FOR PROPER NAMES AND NUMBERING SEQUENCE. 12. COORDINATE LOCATION OF PLUMBING EQUIPMENT TO PROVIDE CLEARANCES FOR REMOVAL AND SERVICE OF LIGHTING FIXTURES AND ACCESS FOR MAINTENANCE OF EQUIPMENT. 13. PLUMBING DRAWINGS DO NOT INDICATE ALL INTERFACING EQUIPMENT AND COMPONENTS. COORDINATE WITH OTHER PROJECT DRAWINGS AND DOCUMENTS FOR WORK OF OTHER TRADES. 14. MAINTAIN HEADROOM CLEARANCES PER MINIMUM OSHA STANDARDS OR AS ALLOWED BY THE AUTHORITY HAVING JURISDICTION UNLESS NOTED OTHERWISE. 15. COORDINATE ALL SLAB PENETRATIONS AND SLEEVES WITH THE GENERAL CONTRACTOR PRIOR TO EACH CONCRETE POUR. 16. PROVIDE TRAPS WITH PROTECTION ON ALL FLOOR DRAINS, GARAGE DRAINS, AND TRENCH DRAINS, EXCEPT WHERE DRAINS FLOW INTO OIL/WATER SEPARATORS OR STORM WATER VAULTS. 17. FOR WATER HEATERS, INSTALLED IN UNCONDITIONED SPACES OR ON CONCRETE SLABS, AN INSULATED INCOMPRESSIBLE FLOOR PAD (R-10 MINIMUM) IS REQUIRED. PROVIDE 1i" TALL PAN WHERE INSTALLED ABOVE A CEILING. 18. PIPING INSULATION SHALL COMPLY WITH THE LATEST APPROVED VERSIONS OF THE INTERNATIONAL MECHANICAL AND ENERGY CODES AS DESIGNATED BY THE LOCAL JURISDICTION. 19. ALL MOTOR STARTERS NOT SHOWN IN EQUIPMENT SCHEDULES SHALL BE FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. MOTOR EFFICIENCIES TO MEET OR EXCEED CODE MINIMUM. 20. WASTE AND STORM DRAIN PIPE SHALL BE SLOPED AT 4" PER FOOT UNLESS OTHERWISE NOTED. 21. ELECTRICAL METERING OF SYSTEMS AS REQUIRED BY ENERGY CODE SECTION C409 IS BY ELECTRICAL. THE ELECTRICAL DESIGN & CONTRACTOR TEAM WILL FURNISH THE NECESSARY ELECTRICAL DISTRIBUTION AND METERING COMPONENTS - SEE ELECTRICAL DRAWINGS. THE MECHANICAL CONTRACTOR WILL FURNISH A BUILDING MANAGEMENT SYSTEM CAPABLE OF COLLECTING AND STORING THE INFORMATION WITH A VISIBLE DISPLAY/NOTIFICATION READILY ACCESSIBLE TO OPERATION AND MANAGEMENT PERSONNEL AS REQUIRED. 22. ARCHITECTURAL ACCESS PANELS SHALL BE PROVIDED AND INSTALLED BY GC AT ALL CONCEALED EQUIPMENT AND DEVICE LOCATIONS, UNLESS NOTED OTHERWISE. DRAWING INDEX SHEET NO. SHEET TITLE CURRENT REVISION P0.01 SCHEDULE SHEET - PLUMBING 3 P2.00 FOUNDATION PLAN - PLUMBING 2 P2.01D 1ST FLOOR DEMO PLAN - PLUMBING 2 P3.01 ENLARGED FLOOR PLANS - PLUMBING 3 P5.01 DETAIL SHEET - PLUMBING 3 APN NUMBER 734560-0385 LEGAL DESCRIPTION RIVERTON ADD LOTS 1 THRU 8 & 27 THRU 34 IN BLOCK 8 OF RIVERTON REPEAT TGW LOTS 1 THRU 8 & 25 THRU 32 BLOCK 7 TGW PORTION LOTS 9 & 24 IN BLOCK 7 AND OF VACATED 37TH AVE S UNDER VACATION ORDINANCE NO 1937 RECORDING NO 20001227002657 LY NORTH OF FOLLOWING DESCRIBED LINE - BEGIN SW CORNER OF BLOCK 7 TH N 01-46-02 E 400.41 FT TO POINT OF BEGINNING TH N 90-00-00 E 420.13 FT TO POINT ON WLY LINE OF BLOCK 8 AND TERMINUS OF SAID LINE TGW PORTION OF VACATED 37TH AVE SOUTH ADJOINING BLOCK 7 AND 8 LESS PORTION OF BLOCK 8 LY ELY OF W MARGIN OF EAST MARGINAL WAY LESS N 10 FT OF LOTS 1 & 34 BLOCK 8 LESS N 10 FT OF LOTS 1 & 32 OF BLOCK 7 - REVISED LOT A OF CITY OF TUKWILA BOUNDARY LINE ADJUSTMENT NO 12000 027 RECORDING NO 200102211001777 Boulevard Park +BEM VICINITY MAP NO SCALE AREA OF WORK (1ST FLOOR) MINIMUM PIPE INSULATION LAST UPDATED: 07/11/16 FLUID DESIGN OPERATING TEMP °F INSULATION CONDUCTIVITY NOMINAL PIPE DIAMETER INCH) CONDUCTIVITY RANGE MEAN TEMP RATING °F <1 1 TO <1-1/2 1-1/2 TO <4 4 TO <8 >8 HEATING SYSTEMS (STEAM, CONDENSATE, HYDRONIC HOT WATER, DOMESTIC HOT WATER & RECIRC) >350 0.32-0.34 250 4.5 5.0 5.0 5.0 5.0 251-350 0.29-0.32 200 3.0 4.0 4.5 4.5 4.5 201-250 0.27-0.30 150 2.5 2.5 2.5 3.0 3.0 141-200 0.25-0.29 125 1.5 1.5 2.0 2.0 2.0 105-140 0.21-0.28 100 1.0 1.0 1.5 1.5 1.5 DOMESTIC COLD WATER AND HORIZONTAL RAIN LEADERS TO FIRST VERTICAL RAIN LEADER (TO PREVENT CONDENSATION) N/A 0.21-0.27 75 0.5 0.5 0.5 0.5 0.5 COOLING SYSTEMS (CHILLED WATER, BRINE AND REFRIGERANT, WATERSIDE ECONOMIZER SYSTEMS)** 40-60 0.21-0.27 75 0.5 0.5 1.0 1.0 1.0 <40 0.20-0.26 75 0.5 1.0 1.0 1.0 1.5 NOTE: * NOT REQUIRED FOR STRAINERS, CONTROL VALVES & BALANCING VALVES ASSOCIATED WITH PIPING 1" OR LESS IN DIA. ** TYPICAL CONDENSER WATER PIPE IN NON -ECONOMIZER SYSTEMS IS NOT INSULATED SEE R403 FOR RESIDENTIAL INSTALLATIONS. REVISIONS No changes shall be made to the scope of work without prior approval of the. Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan rev SEPARATE PERMIT REQUIRED•FOR: [� Mechanical [><•j' Electrical ❑ Plumbing LEY Gas Piping City of Tukwila BUILDING DIVISION FILE COPY Permit No. prOCi 7 Plan review approval is subject to errors ano omissions Approval of construction documents does not auth.rize the violation of any adopted code or ordinance. Receipt of approved Field Copy and f.onditions iSityCKNI ged: By:J'vv' Date: , 2, 13 ! 11 City of Tukwila BUILDING DIVISION REVISION NO,L RECEIVED CITY OF TUKWILA DEC" 1 0 2018 PERMIT CENTER Hermanson Building Today, Defining Tomorrow Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (206) 575-9800 www.hermanson.com Contractor Reg f: HERMACLOO5BJ LEO STELLA TI 12401 E MARGINAL WAY S TUKWILA, WA 98168 December 5, 2016 Revisions REVIEWED FOR CODE COMPLIANCE -APPROVED -DEC 1 7.2010 en- IM BUILDING DIVISION 4A. 12/05/18 SL PERMIT ;REV3 09/19/18 SL PERMIT ;REV2 08/08/18 SL PERMIT REV1 07/13/18 SL ISSUE FbR PERMIT No. Date By Descriition --1111011=11111111111-- Design Team Design Drawn SL KD Checked DIN Pre Construction Number Construction Number Issue Date 2418-13166 XX-XX-XXXXX 07/13/18 SCHEDLUE SHEET - PLUMBING P0.00 FOR CITY USE ISSUE FOR PERMIT ° ' wr -v -vw,w ELECTRIC WATER HEATER SCHEDULE - INSTANTANEOUS LAST UPDATED 12/05/18 UNIT TAG LOCATION FIXTURES SERVED BASIS OF DESIGN MODEL EWT °F LWT °F DESIGN GPM MIN FLOW RATE GPM MAX FLOW RATE GPM MAX LWT °F MIN WATER PSIG ELECTRICAL FULL LOAD AMPS REMARKS KW V/PH EWH-B1-01 LEVEL 1 SHOWER 1 LAV AND 1 SHWR EEMAX EX160TC 50 123 1.5 0.7 2.5 120 40 16 277/1 58(2X29) 1,3,8 ERAL ALL TRADES TO CONFIRM EQUIPMENT REQUIREMENTS (ELECTRICAL, WEIGHT, SIZE, ETC...) WITH APPROVED SUBMITTALS PRIOR TO INSTALLATION; FIELD COORDINATE FINAL LOCATION & INSTALL PER MANUFACTURERS REQUIREMENTS 1 HARD WIRED CONNECTION AND DISCONNECT AS REQUIRED BY ELECTRICAL CONTRACTOR 3 THERMOSTATIC CONTROL WITH FIELD ADJUSTABLE TEMPERATURE SETTING ON MAXIMUM LEAVING WATER TEMPERATURE 8 UNDER COUNTER INSTALLATIONS ONLY PLUMBING DRAIN SCHEDULE LAST UPDATED: 8/8/18 REMARKS SYMBOL DESCRIPTION TYPE MANUFACTURER AND MODEL NUMBER SD OD W V GPM FD-1 FLOOR DRAIN NICKEL BRONZE, ROUND ADJUSTABLE STRAINER JR SMITH 2005-A - - 2 1.5 - 1 TPV-1 TRAP PRIMER VALVE PRFSSURE ACTIVATED TRAP PRIMER VALVE PPP PO-500 - - - - - 2 FFD-1 FUNNEL FLOOR DRAIN NICKEL BRONZE, ADJUSTABLE STRAINER JR SMITH 2005-A WITH 3591 FUNNEL - - 2 1.5 - 1 FCO-1 FLOOR CLEANOUT NICKEL BRONZE TOP, ABS PLUG, ADJUSTABLE JR SMITH 4024S - - DWG - - WCO-1 WALL CLEANOUT CAST IRON TEE, NICKEL BRONZE COVER, ABS PLUG JR SMITH 4530S - - DWG - - GENERAL ALL TRADES TO CONFIRM EQUIPMENT REQUIREMENTS (ELECTRICAL, WEIGHT, SIZE, ETC..) WITH APPROVED SUBMITTALS PRIOR TO INSTALLATION; FIELD COORDINATE FINAL LOCATION & INSTALL PER MANUFACTURERS REQUIREMENTS GENERAL ALTERNATEPRODUCTS ACCEPTABLE AS APPROVED BY THE ENGINEER 1 PROVIDE PIPED TRAP PRIMER CONNECTION FROM TPV-1 2 PROVIDE WITH DU-U DISTRIBUTION UNIT MIXING VALVE STATION SCHEDULE LAST UPDATED: 07/10/18 UNIT TAG LOCATION SERVES BASIS OF DESIGN MODEL # OR TYPE MIN GPM MAX GPM PRESSURE DROP PSI IN TEMP °F OUT TEMP °F REMARKS MV-101 LAVATORY LAVATORY LEONARD 270-LF 0.25 5.5 10 120 90-110 1,2 GENERAL ALL TRADES TO CONFIRM EQUIPMENT REQUIREMENTS (ELECTRICAL, WEIGHT, SIZE, ETC...) WITH APPROVED SUBMITTALS PRIOR TO INSTALLATION; FIELD COORDINATE FINAL LOCATION &INSTALL PER MANUFACTURERS REQUIREMENTS 1 CERTIFIED TO MEET LOW LEAD REQUIREMENTS WITH WETTED SURFACES CONTAINING LESS THAN .25% LEAD 2 ASSE 1070 CERTIFIED, LOW VOLUME THERMOSTATIC MIXING VALVE STATION. REVIEWED FOR CODE COMPLIANCE APPROVED DEC 17 2018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA DEC`1 0 2018 PERMIT CENTER e s Building Today, Defining Tomorrow Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (206) 575-9800 www.hermanson.com Contractor Reg ;I: HERMACLOO5BJ LEO STELLA TI 12401 E MARGINAL WAY S TUKWILA, WA 98168 December 5, 2018 Revisions 12/05/18 SL PERMIT REV3 09/19/18 SL PERMIT REV2 08/08/18 SL PERMIT REV1 07/13/18 SL ISSUE FOR PERMIT No. Date By Description Design Design Team SL Drawn KDE Checked DTN Pre Construction Number 21-18-13166 Construction Number XX—XX—XXXXX Issue Date 07/13/18 SCHEDLUE SHEET - PLUMBING 0.01 FOR CITY USE ISSUE FOR PERMIT "cw L 1, = =I I I I I I I I I I 1 II-1 11 1 I 11 I I I I I I I I I 1 ,( Li I , = L 7 it 11 11 11 -11111F- L P P P C- n II I II II CJL L-- L \4FCO 4"W UP 4"FC0 1 "cW I I/ F.E.C. C-- 2"W 0 0 0 f—= { i a J. 1 cD, L I 11 LL 2"W I) a"CW HB 4"W 1 4"FC0 C FOUNDATION DEMO PLAN - PLUMBING SCALE: 1 /8" = 1'-0" 0 4"W I J REVIEWED O CODE COMPLIANCE APPROVED DEC 17 2018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA DEC 1 0 2018 PERMIT CENTER e s Building Today, Defining Tomorrow Hermanson Company UP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (206) 575-9800 www.hermanson.com Contractor Reg j: HERMACLOO5BJ LEO STELLA TI 12401 E MARGINAL WAY S TUKWILA, WA 98168 December 5, 2019 Revisions 12/05/18 SL PERMIT REVS 09/19/18 SL PERMIT REV2 _ 08/08/18 SL PERMIT REV1 07/13/18 SL ISSUE FOR PERMIT No. Date By Description Design Design Team SL Drawn KDE Checked DTN Pre Construction Number Construction Number Issue Date 21-18-13166 XX—XX—XXXXX 07/13/18 FOUNDATION DEMO PLAN - PLUMBING P2.00 FOR CITY USE SCALE: a"=1' 1 ' 3' 5' 10' 15' 25' ISSUE FOR PERMIT ca i i J 4'hN UP&DN • f 1 EMOVE EXISTING SIN( CAP, (STING WASTE BELOW FLOOR WATER & VENT ONES ABOVE 2"V DN EIUNG 3"v REMOVE EXISTING EXISTING WASTE BEL & WATER & VENT —UN e, MA 1ST FLOOR DEMO PLAN - PLUMBING SCALE: 1/8" = 1'-0" I- K CAP, FLOOR ABOVE CEILING 2°V 4 — I f3"V I I 1 REMOVE EXISTING SINK CAP, EXISTING WASTE BELOW FLOOR & WATER & VENT UNES ABOVE CEILING E REVIEWED FOR CODE COMPLIANCE APPROVED DEC 172018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA DEC .10 2018 PERMIT CENTER e s Building Today, Defining Tomorrow Hermanson Company LIP 1221 2nd Avenue North Kent, Washington S8032 Tel: (206) 575-9700 Fax: (206) 575-9800 www.hermanson.com Contractor Reg I: HERMACLOO5BJ LEO STELLA TI 12401 E MARGINAL WAY S TUKWILA, WA 98168 December 5, 2016 Revisions 12/05/18 SL PERMIT REV3 09/19/18 SL PERMIT REV2 08/08/18 SL PERMIT REV1 07/13/18 SL ISSUE FOR PERMIT No. Date By Description Design Design Team SL Drawn KDE Checked DTN Pre Construction Number 21-18-13166 Construction Number XX—XX—XXXXX Issue Date 07/13/18 1ST FLOOR DEMO PLAN - PLUMBING P2.01 FOR CITY USE SCALE: s"=1 1 ' 3' 5' 10' 15' 25' ISSUE FOR PERMIT 4 r8 r9 iu) 12 = = ( i."CW nn ri n7.1. iu I 1 1 i ! , 1 i • 1 I L_ _ _ _ _ _ _ _J I_ _ _ _ _ _ _ _ _ 1— — — —1 1-- — — —I 1— — — — 1-- —11— — — —11— — — ----1 1 , = [in L T ce Jj LL, T 11 11 '-1111Ir` uu ) = 7 I-J pr P P ,11 Er- n 1 1 I 1 I 1 1 1 c_ L I ',4"FC0 9 11 11 c_--• r- I 4-"W UP BIM PIM ▪ ▪ e▪ l 111111 II = = = = 4"W L. = r — 2'W PAL = 43.0' 1- Fl 1 mcAP / \ 2"W r C z C C 4"FC0 0 ,7 4 FOUNDATION PLAN - PLUMBING SCALE: 1/8" 0 1.0 0 —*— r 7 4"W I I 0 ISM CAP lj L_ -1F -F1 r DW I hi grw I I III I 2'W I III r, i"CW HB CE3 REVIEWED FOR CODE COMPLIANCE APPROVED DEC 17 2018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA DEC i 0 2018 PERMIT CENTER Building Today, Defining Tomorrow Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (205) 575-9800 www.hermanson.com Contractor Reg f: HERMACL0058J LEO STELLA TI 12401 E MARGINAL WAY S TUKWILA, WA 98168 December 5, 2015 Revisions 12/05/18 SL PERMIT REV3 09/19/18 SL PERMIT REV2 08/08/18 SL PERMIT REV1 07/13/18 SL ISSUE FOR PERMIT No. Date By Description Design Design Team SL Drawn KDE Checked DTN Pre Construction Number 21-18-13166 Construction Number XX—XX—XXXXX Issue Date 07/13/18 FOUNDATION PLAN - PLUMBING P2.00 FOR CITY USE SCALE: in=1' 3' 5' 10' 15' 25' :42f 21•5111:165526511661111616500551111 ISSUE FOR PERMIT 5 6� r-Lm I i r r � 0 2"CW —\ \2,V 4"W UP&DN SE SIAM RAN ON NM Ill ' PUMPED COND DN, DISCHARGE INTO FUNNEL DRAIN 2'W & 21, W/WC0 EQUIPMENT & SUB -ASSEMBLY 977 SF PUMPED COND IH-18-051 i"RPBP 3" PUMPED COND DN TO HUMIDIFIER (1YP) 3"NP DN IH-18 INCOMING & STO 908 SF 2'V 051 RAG F. NP we I MPS "CW BAKEOUT 333 SF - - � r-- � ri 9 FLAT -SAT 605 SF 3'V rNP H-18-01 C C }—,._/_._. 1 1110 P AIRLOCK 256 SF C 10 c PUMPED COND NONAI CLEAN ROOM 4330 SF rNP }"PUMPED COND MAI }"NP PeMI PUMPED COND 1 }'PUMPED COND i"PUMPED COND THERMAL & VIB, 369 SF P 2°v ESTS S H-18-04 Min AIRLOCK 422 SF --2 i 9TORAE 03 gF I I --L 3"V == 1:1<l:t . :9.R._6 LL 17 -1 i �[I1 Tr FIT 2"W & 2 V w/wCO 0 DW 211 "cW 'ti S hNia`;i ;71-7F-A—Ar2 CAFETERIA 1698 SF 1ST FLOOR PLAN - PLUMBING CALE: 1/8" = 1'-0" f Dj REVIEWED FOR CODE COMPLIANCE APPROVED DEC 17 2018 City of Tukwila BUILDING DIVISION RECEIV D CITY OF TUKWILA DEO 0 2018 PERMIT CENTER e s Building Today, Defining Tomorrow Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (206) 575-9800 www.hermanson.com Contractor Reg #: HERMACLOO5BJ LEO STELLA TI 12401 E MARGINAL WAY S TUKWILA, WA 98168 December 5, 2018 Revisions 12/05/18 SL PERMIT REV3 09/19/18 SL PERMIT REV2 08/08/18 SL PERMIT REV1 _ 07/13/18 SL ISSUE FOR PERMIT No. Date By Description S Design Design Team SL Drawn KDE Checked DTN Pre Construction Number 21-18-13166 Construction Number XX—XX—XXXXX Issue Date 07/13/18 1ST FLOOR PLAN - PLUMBING 2.01 FOR CITY USE SCALE: "=1 ISSUE FOR PERMIT WO ���A" 1ST FLOOR ENLARGED PLAN - PLUMBING SCALE: 1/4" = 1'-0" 4"FC0 yU MQ K FOUNDATION ENLARGED PLAN - PLUMBING � SCALE: 1/4" = 1'-0" REVIEWED FOR CODE COMPLIANCE • APPROVED DEC 172018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA DEC 102018 PERMIT CENTER e s Building Today, Defining Tomorrow Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (206) 575-9800 www.hermanson.com Contractor Reg #: HERMACL005BJ LEO STELLA TI 12401 E MARGINAL WAY S TUKWILA, WA 98168 December 5, 2016 Revisions 12/05/18 SL PERMIT REV3 09/19/18 SL PERMIT REV2 08/08/18 SL PERMIT REV1 _ 07/13/18 SL ISSUE FOR PERMIT No. Date By Description Design Design Team SL Drawn KDE Checked DTN Pre Construction Number 21-18-13166 Construction Number XX—XX—XXXXX Issue Date 07/13/18 ENLARGED FLOOR PLANS - PLUMBING 3.01 FOR CITY USE SCALE:=1' 1' 2' 3' 4' 5' 10' 15' 25' ISSUE FOR PERMIT KITCHEN SINK AIR GAP FITTING ELECTRICAL CONNECTION (BY EC) COUNTER TOP N— DISHWASHER HOT WATER SUPPLY HOT WATER STOP VALVE AND SUPPLIES TO SINK FAUCET AND DISHWASHER TO COFFEE MAKER TO DRAIN P—TRAP FLOOR COLD WATER STOP VALVE AND SUPPLIES TO SINK FAUCET AND COFFEE MAKER DISPOSER DISHWASHER DRAIN CONNECTION KITCHEN SINK WITH DISHWASHER, GARBAGE DISPOSER AND COFFEE MAKER P`01 NOT TO SCALE 1r VENT MIN 2" SANITARY TEE TAPPED 1 ' 2" WASTE y MINIMUM WALL CONSTRUCTION SUPPORT BRACKETS 0 TYPE "L" COPPER PIPE U CHROME PLATED WALL ESCUTCHEONS SUPPLY TO FIXTURE LOOSE KEY ANGLE STOP VALVE FLUSH TRAP ADAPTOR 1" TRAP FOR FIXTURE 03 CHROME PLATED WHERE EXPOSED ( TYPICAL LAV/SINK/DF ROUGH -IN DETAIL P5.01, NOT TO SCALE CONSTRUCTION NOTES: 0 PER 2015 WSEC C404.3.1, FOR PUBUC LAVATORIES — MAX. LENGTH FROM HW SOURCE OR CIRCULATINe MAIN TO FAUCET IS 2' FOR 1/2" HW (3' FOR 3/8 FOR OTHER FIXTURES 43' FOR 1/2" HW IS ALLO' FOR HW TO LAVATORIES PROVIDE WITH ASSE 1070 ® MIXING VALVE ON SUPPLY. 14" REQUIRED FOR LAV'S tit DRINKING FOUNTAINS. O3 1}" REQUIRED FOR SINKS REVIEWED FOR CODE COMPLIANCE APPROVED DEC 172018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA DEC1 0 2018 PERMIT CENTER e s Building Today, Defining Tomorrow Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (206) 575-9800 www.hermanson.com Contractor Reg I: HERMACLOO5BJ LEO STELLA TI 12401 E MARGINAL WAY S TUKWILA, WA 98168 December 5, 2018 Revisions 12/05/18 SL PERMIT REV3 09/19/18 SL PERMIT REV2 08/08/18 SL PERMIT REV1 07/13/18 SL ISSUE FOR PERMIT No. Date By Description Design Design Team SL Drawn KDE Checked DTN Pre Construction Number Construction Number Issue Date 21-18-13166 XX—XX—XXXXX 07/13/18 DETAIL SHEET - PLUMBING 5.01 FOR CITY USE ISSUE FOR PERMIT A MV ABS ABV AC AD ADD/ADD'L ADJ AFF AFG AP ARCH ASME ATM BHP BLDG BOP BOT BS BTU BTUH COND CA C TO C CAP CB CENT CFF CFM CI CLG CMU CO CO2 COL CONC COND CONN CONT CONTR COORD CPVC CT CU CW DCVA DDC DEG DI DIA DIFF DISCH DN DOM DR DS DWG DWV EA EFF EL ELEC/ELECT EMER ENT. EQUIP ERW ES ET EWC EWT � IpST/(E) EXT F FA FCO FD FDN FF FFD FIC FIO FLEX FLR FDIC FP FPM FPS FPWH FS GA/GALFr GD GC GEN GND GPH GPM HB HD HDR HG HORIZ HOA HP HR HT HW HWC HX HZ A BC CW D E N N WG NSUL PLUMBING / PIPING ABBREVIATIONS AIR/COMPRESSED AIR AIR ADMITTANCE VALVE ACRYLONITRITE BUTADIENE STYRENE ABOVE AIR COMPRESSOR ACCESS ITION/ADDITIONAL DOOR/AREA DRAIN/AIR DRYER AD ADJACENT/ADJUST/ADJUSTABLE/ADJUSTMENT ABOVE FINISHED FLOOR ABOVE FINISHED GRADE ACCESS PANEL ARCHITECT AMERICAN SOCIETY OF MECHANICAL ENGINEERS ATMOSPHERE ATMOSPHERIC BRAKE HORSEPOWER/BOILER HORSEPOWER BUILDING BOTTOM OF PIPE BOTTOM BLACK STEEL BRITISH THERMAL UNIT BRITISH THERMAL UNITS PER HOUR CONDENSATE COMPRESSED AIR CENTER TO CENTER CAPACITY/END CAP CATCH BASIN CENTRIFUGE/CENTRIFUGAL CAP FOR FUTURE CUBIC FEET PER MINUTE CAST IRON CEILING CONCRETE MASONRY UNIT CLEANOUT/COMPANY/CARBON MONOXIDE CARBON DIOXIDE COLUMN CONCRETE CONDENSATE CONNECT/CONNECTED/CONNECTION CONTINUOUS/CONTINUATION CONTRACTOR COORDINATE CHLORINATED POLYVINYL CHLORIDE COOLING TOWER CUBIC/COPPER/CONDENSING UNIT DOMESTIC COLD WATER DOUBLE CHECK VALVE ASSEMBLY DIRECT DIGITAL CONTROL DEGREE/DEGREES DEIONIZED WATER DIAMETER DIFFERENTIAL/DIFFERENCE/DELTA DISCHARGE DOWN DOMESTIC DRAIN DOWNSPOUT DRAWING DRAIN, WASTE AND VENT EACH EFFICIENCY ELEVATION ELECTRICAL_/ELECTRIC EMERGENCY ENTERING EQUIPMENT ELECTRIC RESISTANCE WELDED EMERGENCY SHOWER EXPANSION TANK ELECTRIC WATER COOLER/ EVAPORATIVE WATER COOLER ENTERING WATER TEMPERATURE EXISTING EXPANSIONEXPOSED/EXPLOSION PROOF EXTERNALEXTERIOR FAHRENHEIT FEED/FILTER FACE AREA FIRE ALARM FLOOR CL N OUT FLOOR DRAIN FOUNDATION FINISH FLOOR FUNNEL FLOOR DRAIN FURNISHED AND INSTALLED BY CONTRACTOR FURNISHED AND INSTALLED BY OWNER FLEXIBLE FLOOR FURNISHED BY OWNER INSTALLED BY OTHERS FREEZE PROOF FIRE PROTECTION FEET PER MINUTE FEET PER SECOND FREEZE PROOF WALL HYDRANT FLOOR SINK, FLOW SWITCH FOOT/FEET GALLON GALVANIZED GARAGE DRAIN GARBAGE DISPOSAL GENERAL CONTRACTOR GENERAL GROUND GALLONS PER HOUR GALLONS PER MINUTE HOSE BIBB HEAD HEADER MERCURY HORIZONTAL HAND -OFF -AUTOMATIC HORSEPOWER HOUR HEIGHT/HEAT TRACE DOMESTIC HOT WATER DOMESTIC HOT WATER CIRCULATING HEAT EXCHANGER HERTZ NSTRUMENT AIR NTERNATIONAL BUILDING CODE NDUSTRIAL COLD WATER NSIDE DIAMETER/DIMENSION NVERT ELEVATION NCH/INCHES NCHES WATER GAUGE NSULATE/INSULATION INV TRW IW KWH KEC LAV LB/LBS LPGLBS/HR LPS LWT MAX MBH MCA MECH MFR MIN MISC MM MPS MTD N NA NC NG NIC NO NO2 NOM NP NTS 02 OC OD ODP ORD OVHD PD PERF PH PLBG POC PRESS PRV PS PSF PSI PSIG PVC QTY R RCVR RD RECIRC RED REF REG RL RPBP RPM RS RV RVD S SAN SAT SD S_C SECT SO SOL SOLV SP SPEC SQ SQ FT SS STRUC SUCT TBD TD TEMP THERM TOP TP TPS TYP UG UNO UPC UR UTIL V VA VAC VB VEL VERT VOL VR VTR WW/ W AG0D WC WCO WH WLD WM WO WP WR WT VNNP INVERT IRRIGATION WATER INDIRECT WASTE KILOWATT HOUR KITCHEN EQUIPMENT CONTRACTOR LAVATORY POUND/POUNDS POUNDS PER HOUR LIQUID PROPANE GAS LOW PRESSURE STEAM LEAVING WATER TEMPERATURE MAXIMUM 1000 BRITISH THERMAL UNITS PER HOUR MINIMUM CIRCUIT AMPACITY MECHANICAL MANUFACTURER MINIMUM MINUTE MISCELLANEOUS MILLIMETERS MEDIUM PRESSURE STEAM MOUNTED NITROGEN NOT APPLICABLE NORMALLY CLOSED/ NOISE CRITERIA NATURAL GAS NOT IN CONTRACT NORMALLY OPEN/ NUMBER NITROUS OXIDE NOMINAL NON -POTABLE NOT TO SCALE OXYGEN ON CENTER OUTSIDE DIAMETER/DIMENSION/ OVERFLOW DRAIN OPEN DRIPPROOF OVERFLOW ROOF DRAIN OVERHEAD PRESSURE DROP/ PIT DRAIN/ PUMP DISCHARGE PERFORATED PHASE PLUMBING POINT OF CONNECTION PRESSURE PRESSURE REDUCING VALVE PRESSURE SWITCH POUNDS PER SQUARE FOOT POUNDS PER SQUARE INCH POUNDS PER SQUARE INCH GAUGE POLYVINYL CHLORIDE QUANTITY RISER / RETURN RECEIVER ROOF DRAIN/ REFRIGERANT DISCHARGE RECIRCULATING/ RECIRCULATE REDUCE/ REDUCING REFERENCE REGULATOR RAIN LEADER REFRIGERANT LIQUID REDUCED PRESSURE BACKFLOW PREVENTER REVOLUTIONS PER MINUTE REFRIGERANT SUCTION RELIEF VALVE RELIEF VALVE DISCHARGE SOIL/ SUPPLY SANITARY SATURATION STORM DRAIN SEATTLE _ CODE SECTION SCREENED OPENING SOLENOID SOLENOID VALVE STATIC PRESSURE/ SPRINKLER SPECIFICATION SQUARE SQUARE FEET SANITARY SEWER STRUCTURAL SUCTION TO BE DETERMINED TEMPERATURE DIFFERENTIAL TEMPERATURE) TEMPORARY THERMOMETER TOP OF PIPE TRAP PRIMER TRAP SEAL TYPICAL UNDERGROUND UNLESS NOTED OTHERWISE UNIFORM PLUMBING CODE URINAL UTILITY VENT/_VOLT VALVE/ VOLT AMPERE/ VACUUM AIR VOLTS ALTERNATING CURRENT/ VACUUM VACUUM BREAKER VELOCITY/ VERIFY EXACT LOCATION VERTICAL VOLUME VENT RISER VENT THROUGH ROOF WASTE/ WIDTH/ WATT WITH WITHOUT WASTE ANESTHESIA GAS DISPOSAL WATER CLOSET WALL CLEANOUT WALL HYDRANT/ WATER HEATER/ WATT HOUR WELDED WATER METER WASTE OIL WATERPROOF/ WEATHERPROOF WASTE RISER WATERTIGHT/ WEIGHT WORKING WATER PRESSURE PLUMBING / PIPING LEGEND I' -*To 411 o ELBOW UP ELBOW DN DIRECTION OF FLOW DIRECTION OF SLOPE DOWN REDUCER TEE OUTLET UP TEE OUTLET DOWN UNION PIPE ANCHOR EXPANSION JOINT STRAINER WITH BLOWDOWN VALVE GATE VALVE GLOBE VALVE BALL VALVE CHECK VALVE PRESSURE REDUCING VALVE FLOW BALANCING VALVE (AUTO OR MANUAL) T&P RELIEF VALVE GAS COCK I' LINE CLEANOUT PRESSURE GAUGE WITH GAUGE COCK THERMOMETER FLEXIBLE CONNECTION J PLUG OR CAP WATER HAMMER ARRESTOR BUTTERFLY VALVE SOLENOID VALVE BACKFLOW PREVENTER II> I --I I> D° I REDUCED PRESSURE BACKFLOW PREVENTER (METER T - GRIN SD - OSD NPCW /NPHW DI WAGD CA CO2 N2 NO2 02 MA MV MPS(#) MPR(#) LPS(#) LPR(#) COND II EWH-1 O METER P&T PORT EXISTING PIPING DEMO PIPING WASTE VENT DOMESTIC HOT WATER -RECIRCULATING DOMESTIC HOT WATER DOMESTIC COLD WATER GREASE WASTE STORM DRAIN OVERFLOW STORM DRAIN NON -POTABLE COLD/HOT WATER DEIONIZED WATER WASTE ANESTHESIA GAS DISPOSAL COMPRESSED AIR CARBON DIOXIDE NITROGEN NITROUS OXIDE OXYGEN MEDICAL AIR MEDICAL VACUUM MEDIUM PRESSURE STEAM SUPPLY MEDIUM PRESSURE STEAM CONDENSATE RETURN LOW PRESSURE STEAM SUPPLY LOW PRESSURE STEAM CONDENSATE RETURN CONDENSATE FLOOR CLEANOUT FLOOR DRAIN / SINK PUMP ROOF DRAIN OR OVERFLOW DRAIN PLUMBING FIXTURES PLUMBING FIXTURE DESIGNATION POINT OF CONNECTION RISER DESIGNATION PLUMBING EQUIPMENT DESIGNATION DRAWING (CIRCLE Efif Pcchanical d Electrical 0,Flumbsng Cps Piping PLUMBING / PIPING GENERAL NOTES 1. ALL WORK SHALL CONFORM TO ALL APPLICABLE CODES AND REGULATIONS, INCLUDING, BUT NOT LIMITED TO THE 2015 IBC, 2015 UPC, 2015 WSEC, 2015 IMC, & SIMILAR YEAR WAC 296-104 BOILER RULES. 2. PLUMBING WORK CONSISTS OF WORK SHOWN ON DRAWINGS, DETAILS Sc DIAGRAMS. THE WORK INCLUDES FURNISHING, INSTALLING, SYSTEM INTEGRATION, TESTING, AND ASSURING PERFORMANCE OF THE SYSTEMS IN ACCORDANCE WITH REQUIREMENTS. THE WORK MAY INCLUDE ELECTRICAL AND ELECTRONIC COMPONENTS AS DESCRIBED IN THE CONTRACT DOCUMENTS. 3. VERIFY SYSTEM AND PERFORMANCE REQUIREMENTS TO ENSURE SYSTEM OPERATES AS DESIGNED. 4. LOCATION AND DETAIL OF ALL EQUIPMENT AND EQUIPMENT CONNECTIONS ARE APPROXIMATE. COORDINATE FINAL EQUIPMENT AND ARRANGEMENT AND INSTALL IN ACCORDANCE WITH OTHER TRADES' APPROVED SUBMITTALS AND DETAIL DRAWINGS AS APPLICABLE. 5. PROVIDE SUPPORTS FABRICATED FROM STEEL MEMBERS FOR INSTALLATION OF EQUIPMENT AS REQUIRED BY EQUIPMENT MANUFACTURER'S INSTALLATION INSTRUCTIONS OR AS SHOWN ON THE DRAWINGS. REQUIRED STRUCTURAL MEMBERS, BOLTS, AND WELDS SHALL BE IN ACCORDANCE WITH THE LATEST AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC) MANUAL. 6. PROVIDE ANCHOR BOLTS OF THE SIZE, TYPE, AND LENGTH RECOMMENDED BY THE EQUIPMENT MANUFACTURER, AS REQUIRED BY EQUIPMENT MANUFACTURER'S INSTALLATION INSTRUCTIONS OR AS SHOWN ON THE DRAWINGS. 7. PROVIDE SUPPORTS AND SEISMIC RESTRAINTS FOR PIPES AND EQUIPMENT AS SPECIFIED OR AS SHOWN ON THE DRAWINGS. IF REQUIRED FOR INSTALLATION, PROVIDE ADDITIONAL STRUCTURAL MEMBERS BETWEEN COLUMNS, JOISTS, AND STRUCTURAL FRAMES TO MEET THE SUPPORT REACTIONS (FORCES, MOMENTS, DEFLECTIONS). STRUCTURAL MEMBERS SHALL BE DESIGNED BY A REGISTERED PROFESSIONAL ENGINEER AND INSTALLED BY G.C. WIRES FOR CEILING SYSTEM, ETC... SHALL NOT BE HUNG FROM PLUMBING EQUIPMENT OR PIPING SUPPORTS. 8. DO NOT CORE DRILL OR DRILL THROUGH BEAMS, COLUMNS, AND SHEAR WALLS UNLESS SHOWN ON THE STRUCTURAL DRAWINGS OR APPROVED BY THE STRUCTURAL ENGINEER. 9. REFER TO ARCHITECTURAL DRAWINGS FOR LOCATION OF CEILING OR SURFACE MOUNTED DEVICES. INSTALL EQUIPMENT IN CONFORMANCE WITH ARCHITECTURAL FEATURES IN THE CENTER OF CEILING TILES, IN THE CENTER OF ROOMS, OR WHERE SHOWN ON ARCHITECTURAL DRAWINGS. WHERE EQUIPMENT IS NOT SHOWN ON ARCHITECTURAL PLANS, OBTAIN DIRECTION FROM THE ARCHITECT PRIOR TO INSTALLATION. 10. COORDINATE ROOF CURB AND FLASHING REQUIREMENTS WITH ARCHITECTURAL PLANS. 11. ROOM NAMES AND NUMBERS ARE FOR REFERENCE ONLY. REFER TO ARCHITECTURAL DRAWINGS FOR PROPER NAMES AND NUMBERING SEQUENCE. 12. COORDINATE LOCATION OF PLUMBING EQUIPMENT TO PROVIDE CLEARANCES FOR REMOVAL AND SERVICE OF LIGHTING FIXTURES AND ACCESS FOR MAINTENANCE OF EQUIPMENT. 13. PLUMBING DRAWINGS DO NOT INDICATE ALL INTERFACING EQUIPMENT AND COMPONENTS. COORDINATE WITH OTHER PROJECT DRAWINGS AND DOCUMENTS FOR WORK OF OTHER TRADES. 14. MAINTAIN HEADROOM CLEARANCES PER MINIMUM OSHA STANDARDS OR AS ALLOWED BY THE AUTHORITY HAVING JURISDICTION UNLESS NOTED OTHERWISE. 15. COORDINATE ALL SLAB PENETRATIONS AND SLEEVES WITH THE GENERAL CONTRACTOR PRIOR TO EACH CONCRETE POUR. 16. PROVIDE TRAPS WITH PROTECTION ON ALL FLOOR DRAINS, GARAGE DRAINS, AND TRENCH DRAINS, EXCEPT WHERE DRAINS FLOW INTO OIL/WATER SEPARATORS OR STORM WATER VAULTS. 17. FOR WATER HEATERS, INSTALLED IN UNCONDITIONED SPACES OR ON CONCRETE SLABS, AN INSULATED INCOMPRESSIBLE FLOOR PAD (R-10 MINIMUM) IS REQUIRED. PROVIDE 1 " TALL PAN WHERE INSTALLED ABOVE A CEILING. 18. PIPING INSULATION SHALL COMPLY WITH THE LATEST APPROVED VERSIONS OF THE INTERNATIONAL MECHANICAL AND ENERGY CODES AS DESIGNATED BY THE LOCAL JURISDICTION. 19. ALL MOTOR STARTERS NOT SHOWN IN EQUIPMENT SCHEDULES SHALL BE FURNISHED AND. INSTALLED BY ELECTRICAL CONTRACTOR. MOTOR EFFICIENCIES TO MEET OR EXCEED CODE MINIMUM. 20. WASTE AND STORM DRAIN PIPE SHALL BE SLOPED AT 1" PER FOOT UNLESS OTHERWISE NOTED. 21. ELECTRICAL METERING OF SYSTEMS AS REQUIRED BY ENERGY CODE SECTION C409 IS BY ELECTRICAL. THE ELECTRICAL DESIGN & CONTRACTOR TEAM WILL FURNISH THE NECESSARY ELECTRICAL DISTRIBUTION AND METERING COMPONENTS - SEE ELECTRICAL DRAWINGS. THE MECHANICAL CONTRACTOR WILL FURNISH A BUILDING MANAGEMENT SYSTEM CAPABLE OF COLLECTING AND STORING THE INFORMATION WITH A VISIBLE DISPLAY/NOTIFICATION READILY ACCESSIBLE TO OPERATION AND MANAGEMENT PERSONNEL AS REQUIRED. 22. ARCHITECTURAL ACCESS PANELS SHALL BE PROVIDED AND INSTALLED BY GC AT ALL CONCEALED EQUIPMENT AND DEVICE LOCATIONS, UNLESS NOTED OTHERWISE. DRAWING INDEX SHEET NO. SHEET TITLE CURRENT REVISION P0.00 COVER SHEET - PLUMBING 1 P0.01 SCHEDULE SHEET - PLUMBING 1 P2.00BD FOUNDATION DEMO PLAN EAST - PLUMBING P2.01 BD 1ST FLOOR DEMO PLAN EAST - PLUMBING P2.00A FOUNDATION PLAN WEST - PLUMBING P2.00B FOUNDATION PLAN EAST - PLUMBING 1 P2.01A 1ST FLOOR PLAN WEST - PLUMBING P2.01 B 1ST FLOOR PLAN EAST - PLUMBING 1 P3.01 ENLARGED FLOOR PLANS - PLUMBING 1 APN NUMBER 734560-0385 LEGAL DESCRIPTION RIVERTON ADD LOTS 1 THRU 8 & 27 THRU 34 IN BLOCK 8 OF RIVERTON REPEAT TGW LOTS 1 THRU 8 & 25 THRU 32 BLOCK 7 TGW PORTION LOTS 9 & 24 IN BLOCK 7 AND OF VACATED 37TH AVE S UNDER VACATION ORDINANCE NO 1937 RECORDING NO 20001227002657 LY NORTH OF FOLLOWING DESCRIBED LINE - BEGIN SW CORNER OF BLOCK 7 TH N 01-46-02 E 400.41 Ff TO POINT OF BEGINNING TH N 90-00-00 E 420.13 FT TO POINT ON WLY LINE OF BLOCK 8 AND TERMINUS OF SAID LINE TGW PORTION OF VACATED 37TH AVE SOUTH ADJOINING BLOCK 7 AND 8 LESS PORTION OF BLOCK 8 LY ELY OF W MARGIN OF EAST MARGINAL WAY LESS N 10 FT OF LOTS 1 & 34 BLOCK 8 LESS N 10 Ff OF LOTS 1 & 32 OF BLOCK 7 -REVISED LOT A OF CITY OF TUKWILA BOUNDARY LINE ADJUSTMENT NO L2000 027 RECORDING NO 200102211001777 S0•• ir.<r.l,s S.Earn, 3< White Center Southern tteignn horewood 1t401 E Ma n51Wa a „„,'Boulevard Park r S. 35 S•SaNeRWAellca 5 t4,3 0.1 E•. nre ,. Burien - five Come,l W 5. S. leC<n Riverton Riverton 'Nights McMK.m Meiyhn vEch S..lu, �SAr lf, SITE MAP NO SCALE AREA OF WORK (1ST FLOOR) Hermanson Building Today, Defining Tomorrow Hermanson Company LIP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (206) 575-9800 www.hermanson.com Contractor Reg #: HERMACLOO5BJ LEO STELLA TI 12401 E MARGINAL WAY S TUKWILA, WA 98168 August 9, 2018 2018.08.09 08:17:39.07'00' Document approved, mechanical design pages Revisions A08/09/18 SL PERMIT REV1 07/13/18 SL ISSUE FOR PERMIT No. Date By Description Design Design Team SL Drawn KDE Checked DTN Pre Construction Number Construction Number Issue Date 21-18-13166 XX-XX-XXXXX 07/13/18 REVIENED FOR CODE COMPLIANCE APPROVED MINIMUM PIPE �.,;iyrc,t 11-:,:1., 0'$ LAST UPDATED: 07/11/16. FLUID DESIGN OPERATING TEMP °F INSULATION CONDUCTIVITY NOMINAL PIPE DIAMETER (INCH) CONDUCTIVITY RANGE MEAN TEMP RATING °F <1 1 TO <1-1/2 1-1/2 TO <4 4 TO <8 >8 HEATING SYSTEMS (STEAM, CONDENSATE, HYDRONIC HOT WATER, DOMESTIC HOT WATER & RECIRC) >350 0.32-0.34 250 4.5 5.0 5.0 5.0 5.0 251-350 0.29-0.32 200 3.0 4.0 4.5 • 4.5 4.5 201-250 0.27-0.30 150 2.5 2.5 2.5 3.0 3.0 141-200 0.25-0.29 125 1.5 1.5 2.0 2.0 2.0 105-140 0.21-0.28 100 1.0 1.0 1.5 1.5 1.5 DOMESTIC COLD WATER AND HORIZONTAL RAIN LEADERS TO FIRST VERTICAL RAIN LEADER (TO PREVENT CONDENSATION) N/A 0.21-0.27 75 0.5 0.5 0.5 0.5 0.5 COOLING SYSTEMS (CHILLED WATER, BRINE AND REFRIGERANT, WATERSIDE ECONOMIZER SYSTEMS)** 40-60 0.21-0.27 75 0.5 0.5 1.0 1.0 1.0 <40 0.20-0.26 75 0.5 1.0 1.0 1.0 1.5 NOTE: * NOT REQUIRED FOR STRAINERS, CONTROL VALVES & BALANCING VALVES ASSOCIATED WITH PIPING 1" OR LESS IN DIA. ** TYPICAL CONDENSER WATER PIPE IN NON -ECONOMIZER SYSTEMS IS NOT INSULATED AND SEE R403 FOR RESIDENTIAL INSTALLATIONS. FILE C'Y Permit No. 10 (011 Plan review approval 13 Sub513Ct to errors and omiasions. Approval of construction documents dogs not au i odzo the violation of any adopted code or ordin nco. Raccipt of approved Field Copy and condiEions is ackn cwlcd ad: By: Date: City of f ul,:w Ia BUILDING D`IICN AEVIS!ONS No changes shell mado to the scope of work without prior approval of Tuke°�lla [3i1�'d nq 0 viF.;lnn NOTE: Revisions wiil rcouiro .� ri:�.v 211 submittal and may include additional n reI' L"a fZeG FOR CITY USE AUG ;1 2018 ity of ukwila BUILDING DIVISION RECEIVE.): CITY OF TUKWILA AUG 092010 PERMIT CENTER ISSUE FOR PERMIT GORREcTION LTR# COVER SHEET - PLUMBING P0.00 PAGE IOF9 HOT WATER CIRCULATION PUMP SCHEDULE LAST UPDATED: 06/06/18 UNIT TAG LOCATION AREA SERVED BASIS OF DESIGN TYPE DESIGN GPM DESIGN HEAD FT MAX HEAD FT MAX PSI CONN SIZE IN CONN TYPE ELECTRICAL WEIGHT LBS REMARKS RPM HP V/PH HWCP-101 MECH RM HW RECIRC GRUNDFOS UP 10-16 BN5ILC INLINE 1 3 5 145 1/2 FNPT - 25 W 115/1 3 1,2,3 ERAL ALL TRADES TO CONFIRM EQUIPMENT REQUIREMENTS (ELECTRICAL, WEIGHT, SIZE, ETC...) WITH APPROVED SUBMITTALS PRIOR TO INSTALLATION; FIELD COORDINATE FINAL LOCATION & INSTALL PER MANUFACTURERS REQUIREMENTS 1 6 FOOT LONG 3-PRONG POWER CORD REQUIRES ELECTRICAL RECEPTACLE 2 BRONZE CONSTRUCTION 3 CONTROLLED BY B&G MODEL AQS-1/2 AQUASTAT AND BUILDING MANAGEMENT SYSTEM PLUMBING FIXTURE CONNECTION SCHEDULE LAST UPDATED: 5/11/18 SYMBOL DESCRIPTION TYPE MANUFACTURER AND MODEL NUMBER HW CW W V GPF/ GPM REMARKS L-1 LAVATORY (ADA/NON ADA) COUNTER TOP, SENSOR FAUCET (BATTERY) SLOAN SS 3002, 20 X 17, CHICAGO EQ-D12A-13ABCP 1/2 1/2 2 1.5 0.5 1,2,3 S-1 SINGLE COMP. SINK (ADA) S.S. SINGLE COMPARTMENT, COUNTERTOP ELKAY LRADQ-2219-55-3, 18 GA. SS, 22X19, DELTA 100-WF-8" FAUCET 1/2 1/2 2 1.5 - 4,6 SH-1 SHOWER STALL (ADA) 36" BARRIER FREE AM. REINFORCED PLASTICS S-3842-H, DELTA T13020-R1000 SINGLE-HNDL SHOWER VLV 1/2 1/2 2 1.5 ' 1.75 5 SH-2 SHOWER STALL 36" AM. REINFORCED PLASTICS S-3842-H, DELTA T13020-R1000 SINGLE-HNDL SHOWER VLV 1/2 1/2 2 1.5 is, 1.75 - DW-1 DISHWASHER UNDERCOUNTER, UNIT BY OTHERS DELTA 72020 AIRGAP FITTING 1/2 - 1 - - 7 REF-1 REFRIGERATOR ICE MAKER UNIT BY OTHERS SIOUX CHIEF OXBOX 696-G1010 - 1/2 - - - 8 CM-1 COFFEE MAKER UNIT BY OTHERS SIOUX CHIEF OXBOX 696-G1010 - 1/2 - - - 10 IH-1 INSTA-HOT COUNTER MOUNT IN SINK ERATOR GN3, 120V, 750W, 6.25A - 1/4 - - - 9 WFTR-1 WATER FILTER UNDER COUNTER KOHLER K-77685-NA FILTER SYSTEM - 1/2 - - - GENERAL ALL TRADES TO CONFIRM EQUIPMENT REQUIREMENTS (ELECTRICAL, WEIGHT, SIZE, ETC...) WITH APPROVED SUBMITTALS PRIOR TO INSTALLATION; FIELD COORDINATE FINAL LOCATION & INSTALL PER MANUFACTURERS REQUIREMENTS GENERAL ALTERNATE PRODUCTS ACCEPTABLE AS APPROVED BY THE ENGINEER 1 PROVIDE MAX 2' RUNOUT FROM RECIRC HOT WATER MAIN TO PUBLIC LAVATORIES AND PROVIDE MV-101 2 PROVIDE WHITE PROFLO PFSCPT SERIES INSULATION FOR P-TRAP AND SUPPLIES PER ADA REQUIREMENTS 3 1-1/4 17 GA P-TRAP CP, MCGUIRE 155A GRID DRAIN, BRASSCRAFT LOOSE -KEY CP ANGLE VALVE WITH BRAIDED FLEXIBLE HOSE, ASSE 1070 MIXING VALVE, POWERS LFE480 ON HOT WATER SUPPLY 4 PROVIDE JUST J-35 SS CUP STRAINER WITH REMOVABLE BASKET, 1-1/2 17 GA CP P-TRAP, BRASSCRAFT LOOSE-CP KEY LAV SUPPLY KIT, BRAIDED FLEXIBLE HOSE IF NEEDED 5 PROVIDE DELTA RPW324WHHDF HAND -SHOWER, PUSH-BUTTON ON/WATER-SAVER, 69" SPIRAL HOSE, 24" GRAB BAR, JONES STEPHENS D40-140 BRASS BODY SHOWER DRAIN, SS STRAINER 6 PROVIDE INSINKERATOR BADGER-5 GARBAGE DISPOSAL UNIT (1/2 HP @120V/1PH) 7 DISHWASHER PROVIDED BY OTHERS. WATER SERVICE BY PC, CONNECT DRAIN TO AIR GAP FITTING AND TO SINK TAILPEICE OR GARBAGE DISPOSER 8 ABS BOX WITH QUARTER TURN STOP VALVE, WATER HAMMER ARRESTOR, 1/4"OD COMPRESSION OUTLET 9 PROVIDE SHOCK ARRESTOR FOR EQUIPMENT WITH QUICK CLOSING VALVES (I.E. DISHWASHERS, ICE MAKERS, INSTAHOTS). SEATTLE ONLY 10 PROVIDE SHUT-OFF AND WATER SERVICE ELECTRIC ATER HEATER SCHEDULE LAST UPDATED: 7/10/2018 UNIT TAG LOCATION SERVES BASIS DESIGN TYPE STORAGE CAPACITY GALLONS EWT °F LWT °F RECOVERY RATE GPH ELECTRICAL WEIGHT LBS REMARKS KW V/PH EWH-1B-01 PLUMBING CLOSET SHOWER ROOMS AO SMITH DRE-80-9 TANK 80 50 140 37 9 480/3 260 1,2 IERAL ALL TRADES TO CONFIRM EQUIPMENT REQUIREMENTS (ELECTRICAL, WEIGHT, SIZE, ETC...) WITH APPROVED SUBMITTALS PRIOR TO INSTALLATION; FIELD COORDINATE FINAL LOCATION & INSTALL PER MANUFACTURERS REQUIREMENTS 1 HARD WIRED CONNECTION AND DISCONNECT AS REQUIRED BY ELECTRICAL CONTRACTOR 2 PRESSURE/TEMPERATURE RELIEF VALVE PIPE TO FLOOR DRAIN, FLOOR SINK, MOP SINK OR EXTERIOR WITH AIR GAP LAST UPDATED: 06/06/18 UNIT TAG LOCATION SERVES BASIS OF DESIGN TYPE POSITION DIA INCHES HEIGHT INCHES CAPACITY GALLONS ACCEPTANCE GALLONS MIN TEMP (°F) MAX TEMP (°F) PRESS RATING (PSI) WEIGHT LBS REMARKS ET-B1-01 WH ROOM EWH-B1-01 AMTROL ST-5 DIAPHRAGM VERTICAL 8.0 12.0 2 1 50 140 125 35 1 L TRADES TO CONFIRM EQUIPMENT REQUIREMENTS (ELECTRICAL, WEIGHT, SIZE, ETC...) WITH APPROVED SUBMITTALS PRIOR TO INSTALLATION; FIELD COORDINATE FINAL LOCATION & INSTALL PER MANUFACTURERS REQUIREMENTS 1 (NON ASME) RATED CONSTRUCTION PLUMBING DRAIN SCHEDULE LAST UPDATED: 8/8/18 SYMBOL DESCRIPTION TYPE MANUFACTURER AND MODEL NUMBER SD OD W V GPM REMARKS FD-1 FLOOR DRAIN NICKEL BRONZE, ROUND ADJUSTABLE STRAINER JR SMITH 2005-A - - 2 1.5 - 1 TPV-1 TRAP PRIMER VALVE PRESSURE ACTIVATED TRAP PRIMER VALVE PPP P0-500 - - - - - 2 FFD-1 FUNNEL FLOOR DRAIN NICKEL BRONZE, ADJUSTABLE STRAINER JR SMITH 2005-A WITH 3591 FUNNEL - - 2 1.5 - 1 FCO-1 FLOOR CLEANOUT NICKEL BRONZE TOP, ABS PLUG, ADJUSTABLE JR SMITH 4024S - - DWG - - WCO-1 WALL CLEANOUT CAST IRON TEE, NICKEL BRONZE COVER, ABS PLUG JR SMITH 4530S - - DWG - - GENERALALL TRADES TO CONFIRM EQUIPMENT REQUIREMENTS (ELECTRICAL, WEIGHT, SIZE, ETC...) WITH APPROVED SUBMITTALS PRIOR TO INSTALLATION; FIELD COORDINATE FINAL LOCATION & INSTALL PER MANUFACTURERS REQUIREMENTS GENERAL ALTERNATE PRODUCTS ACCEPTABLE AS APPROVED BY THE ENGINEER 1 PROVIDE PIPED TRAP PRIMER CONNECTION FROM TPV-1 2 PROVIDE WITH DU-U DISTRIBUTION UNIT MIXING VALVE STATION SCHEDULE LAST UPDATED: 07/10/18 UNIT TAG LOCATION SERVES BASIS OF DESIGN MODEL # OR TYPE MIN GPM MAX GPM PRESSURE DROP PSI IN TEMP °F OUT TEMP °F REMARKS MV-101 LAVATORY LAVATORY LEONARD 270-LF 0.25 5.5 10 120 90-110 1,2 GENERAL ALL TRADES TO CONFIRM EQUIPMENT REQUIREMENTS (ELECTRICAL, WEIGHT, SIZE, ETC...) WITH APPROVED SUBMITT PRIOR TO INSTALLATION; FIELD COORDINATE FINAL LOCATION &INSTALL PER MANUFACTURERS REQUIREMENTS 1 CERTIFIED TO MEET LOW LEAD REQUIREMENTS WITH WETTED SURFACES CONTAINING LESS THAN .25% LEAD 2 ASSE 1070 CERTIFIED, LOW VOLUME THERMOSTATIC MIXING VALVE STATION. RECEIVED CITY OF TUKV Building Today, Defining Tomorrow Hermanson- Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (206) 575-9800 www.hermanson.com Contractor Reg #: HERMACL0058J LEO STELLA TI 12401 E MARGINAL WAY S TUKWILA, WA 98168 August 9, 2018 Revisions Z\ 08/09/18 SL PERMIT REV1 07/13/18 SL ISSUE FOR PERMIT No. Date By Description Design Design Team SL Drawn KDE Checked DIN Pre Construction Number Construction Number Issue Date 21-18-13166 XX—XX—XXXXX 07/13/18 REVIEWED FOR CODE COMPLIANCE APPROWED AUG 21 ?018 City of Tiicwila i3WILDING D VISION AUG 092018 PERMIT CENTER ISSUE FOR PERMIT FOR CITY USE SCHEDULES SHEET - PLUMBING PAGE 2 OF 9 12 Lj F.F.E. = 43.0' 1 r 1 1 ui DV 2"W --/f i"CW H 3 4"FC0 4"W FOUNDATION DEMO PLAN EAST - PLUMBING SCALE: 1/8" = I.E. = 37.0' (FIELD VERIFY) CB REVIEWED FOR CODE COMPLIANCE APPROVED AUG 21 2018 City of Tukwila BUILDING DIVISION RECEIVED IT'! OF TUKWILA AUG 0 9 2018 PERMIT CENTER ISSUE FOR PERMIT Building Today, Defining Tomorrow Hermanson Company LIP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (206) 575-9800 www.hermanson.com Contractor Reg #: HERiViACLOO5BJ LEO STELLA TI 12401 E MARGINAL WAY S TUKWILA, WA 98168 August 9, 2018 Revisions 08/09/18 SL PERMIT REV1 07/13/18 SL ISSUE FOR PERMIT No. Date By Description Design Design Team SL Drawn KDE Checked DTN Pre Construction Number 21-18-13166 Construction Number XX—XX—XXXXX Issue Date 07/13/18 FOUNDATION DEMO PLAN EAST - PLUMBING FOR CITY USE SCALE: r= 1 3' 5' 2' 4' 10' 1 5' 25' PAGE 3 OF 9 2 i"CW H8 4 o_ C Ei 1 i I 1 C 92 9112699 PIA 91PIM ii 4"FC0 I 4"W UP 4"FC0 1 I I I 0 cc 9 FOUNDATION PLAN WEST - PLUMBING SCALE: 1/8" = 1'-0" SCALE: s"=1' 4"W REVIEWED FOR CODE COMPLIANCE APPROVED AUG 21 2018 City of Tukwila BUILDING DIVISION RECEIVE CITY OF TUKW AUG 092018 PERMIT CENTER ISSUE FOR PERMIT 1 I I i I I i i I I i I I i I 1 i 1 1 1 1 1 ' 3' 5' 10' 15' 25' Building Today, Defining Tomorrow Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (206) 575-9800 www.hermanson.com Contractor Reg #: HERMACL0056J LEO STELLA TI 12401 E MARGINAL WAY S TUKWILA, WA 98168 August 9, 2018 Revisions 08/09/18 SL PERMIT REV1 07/13/18 SL ISSUE FOR PERMIT No. Date By Description Design Design Team SL Drawn KDE Checked DTN Pre Construction Number 21-18-13166 Construction Number XX—XX—XXXXX Issue Date 07/13/18 FOUNDATION PLAN WEST - PLUMBING PAGE 4 OF 9 I I i I I i I CW 4"FC0 4"W FOUNDATION PLAN EAST - PLUMBING SCALE: 1/8" = 1'-0" SCALE: 8"=1 REVIEWED FOR CODE COMPLIANCE APPROVED AUG 212018 City of Tukwila BUILDING DIVISION RECEIVED GITY OF TUKWILA-3/4 AUG 0 9 2018 PERMIT CENTER ISSUE FOR PERMIT Building Today, Defining Tomorrow Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (206) 575-9800 www.hermanson.com Contractor Reg #: HERMACLOO5BJ LEO STELLA TI 12401 E MARGINAL WAY S TUKWILA, WA 98168 August 9, 2018 Revisions Z\ 08/09/18 SL PERMIT REV1 07/13/18 SL ISSUE FOR PERMIT No. Date By Description Design Design Team SL Drawn KDE Checked DTN Pre Construction Number 21-18-13166 Construction Number XX—XX—XXXXX Issue Date 07/13/18 FOUNDATION PLAN EAST - PLUMBING CAP 1 3' 5 10' 1 5' a" CW H 3 25' 8 -7 1 1 1 1 1 1 1 1 1 3 3 NN U 1 1 1 1 n a_ CNI 1 J r J -�C Ci 0 0 A 0 REMOVE EXISTING SINK CAP, ISTING WASTE BELOW FLOOR WATER & VENT LINES ABOVE CEILING 3"V 1 n C C I T; T 1 3'v 2"V X 1 1 1 REMOVE EXISTING SINK CAP, EXISTING WASTE BELOW FLOOR & WATER & VENT LINES ABOVE CEILING ref REMOVE EXISTING SINK CAP, EXISTING WASTE BELOW FLOOR & WATER & VENT-L1f;ES ABOVE lI- CEILING J rC 1ST FLOOR DEMO PLAN EAST - PLUMBING SCALE: 1 /8" = 1'-0" SCALE: s"=1' 1 ' 3' 5' 10' 1 5' 25' 2' 4 Building Today, Defining Tomorrow Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (206) 575-9800 www.hermanson.com Contractor Reg #: HERMACL0058J LEO STELLA TI 12401 E MARGINAL WAY S TUKWILA, WA 98168 August 9, 2018 Revisions 08/09/18 SL PERMIT REV1 07/13/18 SL ISSUE FOR PERMIT No. Date By Description Design Design Team SL Drawn KDE Checked DIN Pre Construction Number Construction Number Issue Date 21-18-13166 XX—XX—XXXXX 07/13/18 1ST FLOOR DEMO PLAN EAST - PLUMBING REVIEWED FOR CODE COMPLIANCE APPROVED AUG 21 2018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA AUG 0 9 2018 PERMIT CENTER ISSUE FOR PERMIT 2 6� CO 2"CW 2"W ON o-c J I 1 H>a -+ H 1 BIM I 0 0 2'V SECONDARY BUILDIN ENTRY 4"W UP&DN 1 I I I i" PUMPED COND DN, DISCHARGE INTO FUNNEL DRAIN 2"W dt 2"V W/WCO H-1B 06 OMING &STD *G" 908 SF PROVIDE TPV-1 AT RPBP DISCHARGE WI r"TP TO BELOW FLOOR 2"V —1 I N JAN. JAN. ELEVATOR ,..t__(-1, 1ST FLOOR PLAN WEST - PLUMBING SCALE: 1 /B" = 1'-0" SCALE: a"=1 3' 5' LOBBY! I I I I i I I TRIUM BLDG. ELEC. V r. BLDG. MDF I I MAIN BUILD GENTRY J_.-1-: 10' 1 5' 4DG. SE URITY 25' A REVIEWED FOR CODE COMPLIANCE APPROVED AUG 21 2018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA AUG 092018 PERMIT CENTER P2.01A ISSUE FOR PERMIT ermanson Building Today, Defining Tomorrow Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (206) 575-9800 www.hermanson.com Contractor Reg #: HERMACL005BJ LEO STELLA TI 12401 E MARGINAL WAY S TUKWILA, WA 98168 August 9, 2018 Revisions 08/09/18 SL PERMIT REV1 07/13/18 SL ISSUE FOR PERMIT No. Date By Description Design Design Team SL Drawn KDE Checked DTN Pre Construction Number Construction Number Issue Date 21-18-13166 XX—XX—XXXXX 07/13/18 1ST FLOOR PLAN WEST - PLUMBING FOR CITY USE ? 1(‘' PAGE 7 OF 10 - - - - -1=-1 • gium,414i,,o43 SECIARY BUILDIN ENTRY I I I I I i" PUMPED COND DN, DISCHARGE INTO FUNNEL DRAIN 211W & 2111/ W/WCO H-1B 06 OMING & ST 908 SF PROVIDE TPV-1 AT RPBP DISCHARGE WI PP TO BELOW FLOOR a I I I I I LOBBY / r TRIUM I I BLDG. ELEC. _J EQUIPMENT & SUB -ASSEMBLY 977 SF i"PUMPED COND i"RPBP H-1B-05 r i"NP pptit i*CW BAKEOUT 333 SF 3"V f PUMPED COND ON TO HUMIDIFIER (TYP) 1"NP ON PUMPED COND H-1B-01 AIRLOCK 256 SF BLDG. MDF [ MAIN BUILD G ENTRY qjp.4= C".1 0 Cs! SE URITY FLAT -SAT 605 SF FH SUPPLY MAIN ENTRY CAP CAe CLEAN ROOM 4330 SF 3"PUMPED COND PPM WIZ iNNP inNP 1" JIP_Al. a: AAR TEsTs PUMPED COND OPEN orFicE 5087 F i'PUMPED COND F L i"PUMPED COND 3V I— CAP CAP CAP cj L 369 bi- 'Cl IHNP F =OD 2"W & 2n1/ WACO BLoo. ELEC, STORAGE J AIRLOCK 422 SF Z:l TO RAG E 11F 1‘1VIR NMENT TEST 72 I Iii _XI ORID / 2wV rHWC imCW CAFETERIA 1698 SF 1ST FLOOR PLAN EAST - PLUMBING SCALE: 1/8" = V-0" SCALE: :1'=1' 1' 3' 5' 10' 15' 25' INV 2' 4' CD REVIEWED FOR CODE COMPLIANCE APPROVED AUG 21 2018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA AUG 0 9 2018 PERMIT CENTER Hermanson Building Today, Defining Tomorrow Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (206) 575-9800 www.hermanson.com Contractor Reg #: HERMACL0058J LEO STELLA TI 12401 E MARGINAL WAY S TUKWILA, WA 98168 August 9, 2018 Revisions A08/09/18 SL PERMIT REV1 07/13/18 SL ISSUE FOR PERMIT No. Date By Description Design Design Team SL Drawn KDE Checked DIN Pre Construction Number Construction Number Issue Date 21-18-13166 XX—XX—XXXXX 07/13/18 1ST FLOOR PLAN EAST - PLUMBING ISSUE FOR PERMIT P2.01 B 3"HWC 1 "CW 21'W ON W/WCO r l EWH—B1-01 HW E a 9 3"HW 11"v 2"W ON W/WCO 2"V iry i"CW'; }"HW =1"V 1. CW u 4"W UPON 1ST FLOOR ENLARGED PLAN - PLUMBING SCALE: 1 /4 = 1 '-0" 5 SCALE: 4"=1 1 2"WUP 0 _��'A9 FOUNDATION EN LARGED NLARGED PLAN -PLUMBING SCALE: 1/4" = 1'-0" 3' 5' S EET ADDED TO SET 4 10' 15' 25' REVIEWED FOR CODE COMPLIANCE APPROVED AUG 21 2018 City of Tukwila BUILDING DIVISION CITY OF TUKWILA AUG 0 9 2018 PERMIT CENTER ISSUE FOR PERMIT Hermanson Building Today, Defining Tomorrow Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (205) 575-9800 www.hermanson.com Contractor Reg #: HERMACL005BJ LEO STELLA TI 12401 E MARGINAL WAY S TUKWILA, WA 98168 August 9, 2018 Revisions 4A, 08/09/18 SL PERMIT REV1 07/13/18 SL ISSUE FOR PERMIT No. Date By Description Design Design Team SL Drawn KDE Checked DTN Pre Construction Number 21-16-13166 Construction Number XX—XX—XXXXX Issue Date 07/13/18 ENLARGED FLOOR PLANS - PLUMBING P3.01 FOR CITY USE °Vb% D PAGE 9 OF 9 2 4'