Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit PG18-0130 - COURTYARD BY MARRIOTT - REMOVE TUBS AND INSTALL SHOWER PAN AND SHOWER VALVES K/RTOILET, P/V VANITY AND R/RVANITY
COURTYARD BY MARRIOTT 16038 WEST VALLEY HWY PGI 8-0130 Parcel No: Address: /'� City f Tukwila a Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431'3670 Inspection Request Line: 206-438'9350 Web site: http://www.TukwilaWA.goy PLUMBING/GAS PIPING PERMIT 0005800005 16038 WEST VALLEY HWY Project Name: COURTYARD BY MARRIOTT Permit Number: PGI8-0130 Issue Date: 11/5/2018 Permit Expires On: 5/4/2019 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: CSM CORP 500 WASHINGTON AVE #3000 C/O STEFFEN TERRY, MINNELPOLIS, OR, 55415 FELIX HERREDA l493NECLEVELAND 'GRE5HAM'OR, 97030 STATE LINE PLUMBING LLC POBOX I56,YA[O[T,WA, 9867S STATELP834N8 I Phone: (503) 572-5458 Phone: (360) 608-7894 Expiration Date: 8/28/2019 DESCRIPTION OF WORK: REMOVE TUBS AND INSTALL SHOWER PAN AND SHOWER VALVES R/R TOILET, R/R VANITY AND R/R VANITY FAUCETS Valuation of Work: $172,000.00 Water District: TUKWILA Sewer District: TUKWILA Fees Collected: $3,600.75 Current Codes adopted by the City of Tukwila: International BuiIdng Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International FueI Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Da1 { Date. I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: v- gooe2-044-4- Date: 1//1 --if r This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work wilt stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 gauge. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1900 PLUMBING FINAL 8005 ROUGH -IN PLUMBING CITY OF TUKWI, A Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Plumbing/Gas Permit No. -N 1 0,0130 Project No. Date Application Accepted: 1( -?-9-( Date Application Expires: ;-1-90-17 (For office use only) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: Site Address: (// 032' Gr & ' //4'4 /A 7' Suite Number: Floor: Tenant Name: ii00 oeV ; /M2(242-,••• PROPERTY OWNER Name: F .- x "it -RI AA,,e) .J• II''`` /c,& Address: /, 1p3 iv� - ( j Name:&wt. Co/ZIN Phone: 5-06 512.`i5`tx: Email:Suc.QOR-t- 14.04-\ .r`tA't' re ---- Address: o (it%.95 Ri le)c,� City ffln/ I ,S tater ZipfiSe CONTACT PERSON - person receiving all project communication Name: F .- x "it -RI AA,,e) .J• II''`` /c,& Address: /, 1p3 iv� - ( j City: / �''eA', M. State: 4p Zip:1,705 0 Phone: 5-06 512.`i5`tx: Email:Suc.QOR-t- 14.04-\ .r`tA't' re ---- New Tenant: Yes PLUMBING CONTRACTOR INFORMATION Company Name:. 4// lo%nz6ius Address: /0.0 _ x rTre City: VaCd H.. State: A Zip:94.. S Phone: 3 to r) bog Contr Reg No.: s..74,7.•� Z Exotfpiate: sits //1 Tukwila Business License No.: .CO Valuation of Project (contractor's bid price): $ / 7.7 14 Scope of Work (please provide detailed information): igiyerk, t- --/-4.4,s awSG►v.od•— pain d064 S.';vw•-r. {� (✓s�5 A/c/... %a,'/4, - 12/x v'�"'''�`� 4/4. 1/-41~:17Ak tAcss Building Use (per Int'! Building Code): Occupancy (per lnt'l Building Code): Utility Purveyor: Water: Sewer: H:1Applications\Forms-Applications On Line12011 Applications\Plumbing Permit Application Revised 8-9-1 1.docx Revised: August 2011 bh Page 1 of 2 \ Indicate type of plumbing fixtures and/of-gds piping outlets being installed and the quantity-velow: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain Shower, single head trap 1'5' Sinks Rain water system — per drain (inside building) Grease interceptor for commercial kitchen (>750 gallon capacity) V Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Fixture Type Qty Bidet Drinking fountain or water cooler (per head) Lavatory Urinal Water heater and/or vent Repair or alteration of water piping and/or water treatment equipment V Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial Wash fountain Water closet Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping t ll Each lawn sprinkler system on any one meter including backflow protection devices Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets Fixture Type Qty Dental unit, cuspidor Floor drain Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR t Signature: � / biLey&J "P Print Name: Mailing Address: /G%f 5 "lig-0-4'0.--L/ e„ -"'/i H:\Applications\Porms-Applications On Line \2011 Applications\Plumbing Permit Application Revised 8-9-11.docx Revised: August 2011 bh Date: /05`,// t Day Telephone: C"0 S ' S-72 • 6.5r4 6✓',C —7o City State Zip Page 2 of 2 DESCRIPTIONS ACCOUNT QUANTITY PermitTRAK PAID $3,600.75 PG18-0130 Address: 16038 WEST VALLEY HWY Apn: 0005800005 $3,600.75 PLUMBING $3,462.26 R000.322.100.00.00 0,00 $2,736.66 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 PLAN CHECK FEE R000.322.103.00.00 0.00 $692.45 TECHNOLOGY FEE $138.49 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R15730 R000.322.900.04.00 0.00 $138.49 $3,600.75 Date Paid: Monday, October 29, 2018 Paid By: FURNITURE FIXTURE SERVICES Pay Method: CHECK 2811 Printed: Monday, October 29, 2018 12:08 PM 1 of 1 YSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431 60 Project: ea:NOW 106106 Type of Inspection: XiittiSti411P '5.440%,.... Address: Pita err 1/444141 ' Date Called: Special Instructions: 2,14 314 104 _ Date a ed: a.M. al 1...14:1 P.m. Requester: Phone No: 16c, 40=e•lefii# pproved per applicable codes. El Corrections required prior to approval. OMMENTS: t 34)t. • I Inspector: Date: ri REINSPECTIO EQUIR . Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100, Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 t coj P, X30 Project: (K l Type of InsD�eection: I(i- d ,,►1iin^'ti Address: I tOa30 IA) dr 1/AL Date Called: h Special Instructions: Ii(i, 46%`-f Daie Wanted:ry., ..-.1-2-S) 9, p.m. Requester: 150 — Phone No: 3fao bct67elLf pproved per applicable codes. EJ Corrections required prior to approval. MMENTS: kik 4 ikki-k • =?o,, ?---- ?ink -44,4 * 1414 Inspector: Date: C REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Nevi ter "rat Gartret veyor INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 1-40, I cv3 Project: ve-' Vi40) Type of Inspection: Pi_J VIA ?::$1 i'll., 4e..).4.4--- Address: )L030' tA,Vrir lhilxsi Date Ca led: Special Instructions: 7 Date nted: P. • Requester: Siet`.1 Phone No: °4Ar:%' (09e3-7819 LJApproved per applicable codes. Corrections required prior to approval. f).Z.AAJAIL "Jai (7f -D ie-4z7K :9/St REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Siiite 190. Call to schedull feins ion. 5/Gtgr 116/t 6r4. bk 00e-tk. 125 iOcee, ?le Ae /ID* (wit '1 2z3 INSPECTION RECORD Retain a copy with permit jP(' l az INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Laitf&r \Oa. Type of In e on: Ca0v11), Address: t CI (Z3v) r‘fr tl'a41 Date Called: Special Instructions: #2.- bate Wanted: 11 19 41...„n p.m. Requester: iliol\,( Phone No: 5cao ‘,06-765q proved per applicable codes. Corrections required prior to approval. COMMENTS: reqc 004 ZLi-v hio<wis e1/441-) tr,51 1%4L- x•1"60 (411131, --eve, . Inspector: Date: s5v- REINSPECTIO EE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 •Pele. oi30 Project: 42>O424l'yk4(4 Type of Inspection: Pi -V Vr} 6 AJZ• 1-1-0,/ 4c- Address: ibia3e7 4457'44y 4 Date Called: Special Instructions: 7a2rriz._ a ed: 44243 "tc) P.m. Requester: 44/W Phone No: 360 Approved per per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 {fife) v(30 Project: a.JZ—C tivel,t6 Type f Inspection: ` t41. ..i{ -•✓tJ — Address: , / /lacySpecial Called: riled: Instructions: 3 ---rte— Dat anted: 14 49- c 1 p.m. Requester: -P1/4/-,4 -.D Phone No: 3(00 (900 el `i' Approved per applicable codes. Corrections required prior to approval. COMMENTS: i\Nkt-\ C-.(2aDrA, Inspector: Date: REINSPECTION EE REQUIRED. Prior to next inspection, fee must be it .40 ot paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 3Rt) ast- INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 'F618 -0E722 Pr : r- di Acrioeyrzo_ft= '3i n: izsyh fit) Address: /607, • Date Called: Ifircial Instructions: Date anted: -0-61 . . 1 I) tak JOY'_ Requester: ter7Z9 Phone No: pproved per applicable codes. JKjorrections required prior to approval. COMMENTS: x_Ltrii4 -7-ck 3)9 2 3a71 3 /3/3/9i 329.327323 —OK P_AAJ.s., IhoLA__ 17,0 :471-Z ALL 0(14 Ws bier 912 ve c -e -r71 -4f 1 A ) t -T ,Uki'cld-: 145/10 1‘, , 16er.--12/97-r " hvolce.tf /gar 44) 1r5/1- re " (97& i r ' " *t - A 0 1,'ii 4 .0 i u 6, ' t s lot 714 y Inspect Date:,; REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 18-013.0 PAject: n ! y 9 ,/ 1 {�9r'�ia%'1 TyVkA.Arn. Inspe ion:/(amu 1 h Av, t /CSD 3a •tAddress: J Vc .11e427,-, Spe ' . i tructio 0?-. Date ted: a,m. p.m. Requester: Phortegi63) 5 7z-52 ElApproved per applicable codes. 'Corrections required prior to approval. COMMENTS: t s� Inspector: 017 Date: '3,-242 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION FDi30 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 oProtiejectlemy, iy •e of Inspection: t Address: v /Os 38 k � . Val Date -.1 led: Special Instructions: L ov6ttif Date Wanted: Requester: l Phone No:►�"/L ,-o3 ,..5-72 - rg Z pproved per applicable codes. LJ Corrections required prior to approval. COMMENTS: RAk ,c2D ,k gilDIARAc � Liners a� coo Vis+ nil Li -:K. Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 5-7/4 fio INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION U6 Ow 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project: p Zaa'rVilA e n 9 1t4L1cY Type of Inspection: PL,J i' \ & -& -‚-'‚it.. Address: 1I 0936 wr fiti, /pecial D to Called: Instructions: o� -5 ate Wanted: Z-Zl - l,411 a.m. p.m. Requester: AdZi-Al Phone No: 3 4A0 (8 9 ❑ Approved per applicable codes. Corrections required prior to approval. COMMENTS: 144/4/64 4d 4.4 5 `1-6- 1C -Lt -A twevv° r.69 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit R,t8-0130 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 P ect: 1149 c of Inspection: i • • ai,, -rig, Address: 40 . • Special Instru ons: anted: — 21'17 p.m. RequesterA t '.10 Phone No: lalt Approved per applicable codes. Corrections required prior to approval. ENTS: f olip4 j/f/ WI M REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION RI as 0112 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project: ICOgf6d/A0 61 *lb dr Type of Inspection: & nk, Pfri4(-- Address: 1Date lie2C Ef. Called: Special Instructions: Date Wanted: h - a,m. p.m. Requester: AAJt4 , ft,..,,c Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 11)14(1db/41 ft-CC4— 4cUi( -413k _1- 1- %/6"-- k5D.7 lAwle-es", t1.e4 AJ -z) P97-40 itcfilsoN itatr" L.1 Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit ON NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: coapepo Af Type c:pnspe ion: Address: 11414C1 Date lied: SiefifIftstructions: Da Wanted: p.m. Requester: Phone No: 3100 40e /6114 EJApproved per applicable codes. E1 Corrections required prior to approval. COMMENTS: PLIMI glipt 141117 Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit ON NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION P613-0130 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project: iliType Pea 4ki-rql iy t/A-rri OTT of s ection:, ill 0/ 4/(1 I Address: y Date Called: Special IVactions: LooY* Date Wanted: RequesAvd Phone No: 0 5(0 Approved per applicable codes. Corrections required prior to approval. COMMENTS: PLu1/4.14-1.101k/ .)(--FLov r- tAri odNi 7 I41 fl9ijAo9C- /4-,9f lnsp, or: )9/7. c11/ff I 5 AO 111/1(`-/- #7/7 1 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcentec Blvd.. Suite 100. C II to schedule reinspection. tO is 11—Ze31) INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION F /g -013o 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project: l&le4-fl�vU rio/ JeofIispec 1� jIJ ltiw4 6 r1 Address: i /603�S W V&�( I-tw , Date ed: Special Instructions: 70 -8 -FL Date Wanted: )Z -7-Z a.m.- 1 Reques, - r. r S `'I�e✓ ,A,Ji 1....„_,5 O,--r'e d S 7/ ` 7 _ �8� r Phone No: /- 408 782/ Approved per applicable codes. Corrections required prior to approval. ZOMMENTS: X S[10LA) - I-inLr— X• uiAJ /._ x- /WL c, 11 ! Q'GV 7 Fizei_ S `'I�e✓ ,A,Ji 1....„_,5 O,--r'e d S 7/ ` or a e- lkL t/_S exci -7 722, 12.3 72-0/ 7Z( 7/c1/ 7/2 a ��e � ;7)3/ d7/ 7 G% 703, `Kase �lvi r 13 r G 41-4J4- PaPvlekl I -o 65...►- ©ice 7 — i2 ''t2 InspectoC i02 Date: / 2- 2-Zz:fy REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: L�,y, * din- Type of Inspection: ii.titiZerd4 f� Address:��// 11.693 :cif—Air Date Called: Special nstructions: fbeii7� _// ./....ja.... Date Wanted:�7 /`- / ` �7 ,, a.m. 2.491( p.m. Requester: y Phone No: 3tooborl3 70i44 Approved per applicable codes. EJ Corrections required prior to approval. COMMENTS: � /SIL t A/[ ;401-- ' Los rin v -7A/1:14 rif (Iva -5 anl REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permitTGI g -Z) INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 PAect:i 1 e Thrakof Inspection: ....a..ce ..T.A) CbtAxilard by Motrr ri- Address: /4039 14/4 ktAl Date Caleb:41 Special Instructions: e *Ple.row4//71-6414 Avt cr4+F-/.. Date Wanted: a.m. pm. Req9c ,ster: iLIA/ct. t" m 151 8/7 ' P Phone No: /-36 0— t706 -78'91i ElApproved per applicable codes. DCorrections required prior to approval. COMMENTS: *9k -a. kov1), At?' tk.,,CA- 00 aft, F1-41=or on( iCS 141,0ey- PA -7J i;, 6.s Inspector: TQQ Date: /s -zo REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. &ke_ 51i3 CTION RECORD a copy with permit Fwg-oco PERMIT NO. UKWILA BUILDING DIVISION outhcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 rct: _T Yffab ii ,e of In pection: pzumilb) - icrttrirrgrclP _ L I j MOr r torr Date ed: ippeertfOlwitwiettaris7— I073g Iiic16.-1- Val I/eyd • Date Wanted: 1 13-2-0GS> -11. P-111. Request r. Phoneelrlo fie) II, ,.... 784 Approved per applicable code . COMMENTS: ed prior to approval. 31 ne 8)33 ho7lk.7- ftakvvii Woe_e Inspector: Dated— /3 ZOg/ REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. SEC T�uX�1�A CO OF AU Dimensions i\re+� 3� PM) 4' 1101.61 .1:11 5,11524 01 3/6• (9.pone 0.11(0.25.41 + zb•I •.41/4•Imloe.ol 11a MAI 4111320.6] 31(6.2/ 3/6.19.5)-1F 0' 11524.01 5.41 2.01 70) 0• (1524 01 u❑❑❑❑❑❑❑❑ 2'-9 3/6 (660.41 1a•1m.q- 4'-0• (1524 01 8 r—Y 1/16'152.0) DETAIL D oklo 11/r (m.0 3060-T-O-L-4 fir (9.51 5.31 2 1/16 (52.41 DETAIL B Mshower Shop Drawing Type 1-Shower Pan 78 sets Matte #302 White REVIEWED FOR~ CODE COMPLIANCE APPROVED OCT 31 2018 City of Tukwila UILDING DIVISION Date Description 01 08-02-17 Initial Release Sloan.. Dale Mshower LLC 203 North Lewis Street LaGrange, GA 30240 ter, rrierres DETAIL C RECEIVED CITY QiFimTLIKWILA OCT 29 2018 PERMIT CENTER Office (706) 837-0008 Fax (706) 837-0073 Project Name City ST Courtyard Lloyd Center Portland OR SO2 PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG18-0130 DATE: 10/29/18 PROJECT NAME: COURTYARD BY MARRIOTT SITE ADDRESS: 16038 WEST VALLEY HWY X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Building Division a lila-6 Public Works Fire Prevention Structural Planning Division Permit Coordinator n PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 10/30/18 Structural Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: Approved Corrections Required DUE DATE: 11/27/18 n Approved with Conditions .&/ n Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg D Fire ❑ Ping ❑ PW 0 Staff Initials: 12/18/2013 STATE LINE PLUMBING LLC Horne Espanol Contact k Washington State Department of / Labor & Industries Safety & Health Claims & Insurance Search L&I Page 1 of 2 iA A -Z Index Help My L&1 Workplace Rights Trades & Licensing STATE LINE PLUMBING LLC Owner or tradesperson Principals MACFARLANE, ANDREW LARS, PARTNER/MEMBER Doing business as STATE LINE PLUMBING LLC WA UBI No. 604 076 575 PO BOX 156 YACOLT, WA 98675 360-608-7894 CLARK County Business type Limited Liability Company Governing persons ANDREW L MACFARLANE KARI MARIE MACFARLANE; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties PLUMBING License no. STATELP834N8 Effective — expiration 08/28/2017— 08/28/2019 Bond Wesco Insurance Co Bond account no. 46WB042914 Active. Meets current requirements. $6,000.00 Received by L&I Effective date 08/28/2017 02/17/2017 Expiration date Until Canceled Insurance Capitol Specialty Ins Corp $1,000,000.00 Policy no. CS17001099-02 Received by L&I Effective date 02/05/2018 02/19/2018 Expiration date 02/19/2019 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. Help us improve https://secureini.wa.gov/verify/Detail.aspx?UM=604076575&LIC—STATELP834N8&SAW= 11/5/2018 STATE LINE PLUMBING LLC L81 Tax debts No L81 tax debts are recorded for this contrb r license during the previous 6 year period, but some >s may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 969,114-02 Doing business as STATE LINE PLUMBING LLC Estimated workers reported Quarter 2 of Year 2018 "Less than 1 Workers" L&I account contact T4 / STEPHEN TASSONI (360)902-4819 - Email: TASS235@Ini.wa.gov Account is current. Public Works Strikes and Debarments Verify the contractor is eligible to perforin work on public works projects, Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health No inspections during the previous 6 year period. Page 2 of 2 G Washington Slate Dept. of Labor & Industries. Use of This site is subject to the laws of the stale of Washington, Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=604076575&LIC=STATELP834N8&SAW= 11/5/2018 ICI\ITY CIA VICINITY MAP fAilk 0111 ,40A SCALE: NTS AO.O SCALE: NTS NORTH STATISTICS: OWNER: GOVERNING CODES: ADDRESS: EXISTING ZONING: CONSTRUCTION TYPE: OCCUPANCY GROUPS: PARKING REQUIRED: PARKING PROVIDED: MISC. BLD6./51TE: C5M LODGING, INC. 500 WASHINGTON AVE. S., SUITE 3000 MINNEAPOLIS, MN 55415 PHONE: 612-315-1000 FAX: 612-315-1002 PROJECT MANAGER: ROBB GULNER 2015 IBC INSTATE AMENDMENTS 2015 IFC W/STATE AMENDMENTS ADA CODE - ICC / ANSI AII7.1-O41 16038 WEST VALLEY HIGHWAY, TUKWILA, WA TUG - TUKWILA URBAN CENTER TYPE II - F.R. HOTEL- GUEST ROOMS: CONFERENCE ROOM: RESTAURANT/KITCHEN: POOL ROOM ADM I N I STRATI ON/LAUNDRY: OUTBU I LD I NGS- GAZEBO: V 201 (VARIANCE APPROVED) 201 STALLS 136 STANDARD 51 COMPACT 2 VAN ACCESSIBLE 6 ACCESSIBLE. SITE AREA: BUILDING FOOTPRINT AREA: IMPERVIOUS AREA: LANDSCAPING AREA: USE: GUESTROOMS: BUILDING HEIGHT: STORI ES: FINISHED FLOOR ELEVATION: REQUIRED USE PERMITS: LIQUOR LICENSE FLOOD ZONE: FLOOR AREAS: "X:: R- I B A-3 A-3 B U-I 2.71 ACRES 18,16g S.F. 85,145 S.F. 23,305 S.F. HOTEL 210 HEIGHT 4;10'- IO" (1/2 WAY UP THE SLOPED ROOF) 8 24.1O' GROUND FLOOR FLOOR AREA FIRST STORY (R-I/A-5) 20,2g7 S.F. SECOND STOR`I(R-I) 14,885 S.F. THIRD STORY (R-I) 15,861 S.F. FOURTH STORY(R-I) 15,861 S.F. FIFTH STORY (R-I) 15,86I S.F. SIXTH STORY (R-I) 15,86I S.F. SEVENTH STORVR-I) 15,86I S.F. EIGHTH STORY (R-I) 15,861 S.F. TOTAL 150,546 S.F. FLOOR AREAS - FIRST STORY GROUP A-5 OCCUPANCY GROUP B OCCUPANCY OTHER OUTDOOR SPACE ALLOWABLE "25g,200 S.F. 6,a2O S.F. 4,655 S.F. 6,614 S.F. 2,128 S.F. TOTAL 20,2g7 S.F. ALLOWABLE AREAS: (TABLE 5B)** BASE MULTI -STORY SEP. (4-SIDES) SPRINKLERED R-I HOTEL / A-3 ASSEMBLY 24'1,4100 S.F. 541,800 S.F. IIg,600 S.F. 23g,200 S.F. * FLOOR AREA CALCULATIONS A5 DEFINED IN UBG SECTION 201 (1gg4 UBG) - (EXCLUDES EXTERIOR COURTYARD) ** BASED ON TYPE II-IHOUR (2g,g00 BASE); AREA INCREASES DUE TO 'MULTI -STORY', SEPARATION OF AT LEAST 40 FEET ON FOUR SIDES (40'-20'=20' ; 20x ..05% = 100% MAX. INCREASE) AND FULLY SPRINKLERED. IN ACCORDANCE WITH NFPA IS. SHEET INDEX AO.O COVER SHEET ARCHITECTURAL AI.O OVERALL 2ND FLOOR PLAN 4 ENLARGED PLANS 4 DETAILS A2.O OVERALL 3RD - STH FLOOR PLAN 4 ENLARGED PLANS PROJECT PARTICIPANTS ARCHITECT: CSM CORPORATION 500 WASHINGTON AVE. 5., SUITE 3000 MINNEAPOLIS, MN 55415 PHONE: 612-3g5-1000 FAX: 612-3415-1002 PROJECT ARCHITECT: JOHN FERRIER LOCAL CONSULTING ARCHITECT: ROBERT EVENSON ASSOCIATES, A I A 6241 5W CANYON COURT PORTLAND OREGON, g7221 PHONE: 503-22I-08Q0 ARCHITECT: BOB EVENSON SITE: COURTYARD BY MARRIOTT - SEATTLE SEATAC 16056 WEST VALLEY HIGHWAY TUKWILA, WA g8188-5542 PHONE: 425-255-0500 FAX: 425-204-4a75 GENERAL MANAGER: ALEX JACOBSEN REVISIONS No changes shall be made to the scope of work without. prior ipproval of Tukwila 6uildirsg Division. Ik OTT: i;avi ions will require a new plan submittal and may include additional plan review fees. 1 UNIT MIX: KING DOUBLE EXTENDED DOUBLE WHIRLPOOL KING KING SUITE CONF. SUITE ACC. KING ACC. DOUBLE ACC. INF. KING TOTALS SUITE "A" CONF. SUITE LOWER FLR: 0 0 0 0 0 0 0 0 0 0 0 SECOND FLR: 16 I I 6 0 I 0 0 I R.I.S. I 21 THIRD FLR: 11 7 3 0 I 0 i I I S O 0 I 30 FOURTH FLR: 17 7 3 0 I 0 I 0 0 0 30 FIFTH FLR: 18 8 2 0 I 0 I 0 0 0 51 SIXTH FLR: IS 8 2 0 I 0 I 1415 0 0 51 SEVENTH FLR: II 8 2 0 I 0 I I 0 0 51 EIGHTH FLR: II 8 2 0 I 0 I 1 0 0 31 TOTALS 124 47 15 6 6 I 6 5 I 2 211 5g% 22.21% 1% 2.SS% 2.85% .47% 2.8% 1.4% .47% .c15% 100% R.I.S. = ROLL -IN SHOWER NOTES: I. 10 ACCESSIBLE ROOMS PROVIDED (ALSO HEARING IMPAIRED ACCESSIBLE) 2. 5 OF 10 ACCESSIBLE ROOMS TO HAVE ROLL -IN SHOWER 3. 7 ADDITIONAL ROOMS TO BE ACCESSIBLE BY THE HEARING I MPA I RED .INTERCONNECTING ROOMS: 66 SEPARATE PERMIT REQU;RED FOR: 0 /Mechanical / IJd Electri(al 0 Plumbing 1 Gas Piping Gliy of Tukwila i i"TIN DIVISION FILE COPY Permit No. Vr (et- 0 3 0 Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted coda or ordinance. Receipt of approved Field Copy and conditions is knowledged: By: Date: City of Tukwila BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED OCT 31 2018 Cityof Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA OCT 2 9 20 ►B PERMIT CENTER ROOM BUILD -OUT COURTYARD SEATAC S ATAG, WASH I N6TON PERMIT SET 10-26-2018 Robert Evenson Associates Architects AIA Architecture Planning Interior Space Planning 6249 SW Canyon Court Portland, Oregon 97221 503-221-0890 REGISTERED •RCHI,. T Cry * 500 Washington Avenue South, Suite 3000 1\J Il\Y/Il Minneapolis, MN 55415 Bus: (612) 395-7000 Fax: (612) 395-7002 DEVELOPING REAL ESTATE FOR PEOPLE, BUSINESS & COMMUNITIES Registration: Date: I0-26'20I8 Reg, No • Drawn By: JASON GRUHN Checked By: Project Manager: ROBB GULNER Date: OCT. 26, 2015 Revisions Project N o. XX-XXXX Sheet Title COVER SHEET Sheet No. AO.O 2ND FLOOR OVERALL PLAN �AI.OJ SCALE: 3/32" = ILO" 4 IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIIIIIIIIIIIIIIII4. _ _ � ° 0 0 0 /��, 1 ° n I i I 1 • / J A A- 22ND FLOOR DEMO PLAN - TYPICAL AT ALL GUEST ROOMS AI.O / SCALE: 3/6" = ILO" GENERAL NOTES I. GENERAL CONTRACTOR 15 TO COORDINATE ALL TRADES FOR THEIR REQUIRED DEMOLITION WORK. 2. DASHED LINES INDICATE WALLS, DOORS AND OTHER ITEMS TO BE REMOVED, UNLESS NOTED OTHERWISE. S. PATCH AND REPAIR ALL EXISTING CEILINGS, PARTITIONS, AND FLOORS DISTURBED FOR NEW WORK AND FINISH. 4. REMOVE FROM SITE AS 500N A5 PRACTICABLE DEMOLISHED MATERIALS, DEBRIS, AND RUBBISH. DO NOT ACCUMULATE DEBRIS ON THE FLOOR OR AT THE SITE. 5. PATCH AND REPAIR HOLES IN EXISTING GYP BD PARTITIONS AFTER REMOVAL OF EQUIPMENT, MECHANICAL AND ELECTRICAL DEVICES AND OUTLETS, ATTACHMENTS, FURNISHINGS, ETC. DEMO KEY NOTES D1 REMOVE EXISTING TUB, SURROUND AND CONTROL VALVE AND PREPARE AREA FOR NEW SHOWER PAN AND NEW CONTROLS. 4 IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII 4- -� 0 ion000 -A A A- 2NFLOOR FLOOR PLAN - TYPICAL AT ALL GUEST ROOMS SCALE: 3/8" = I'-O" GENERAL NOTES I. ALL WORK TO BE COMPLETED - TYPICAL AT EACH GUEST BATHROOM. REPLACE EXISTING TUB WITH NEW SHOWER PAN. 2. SEE ATTACHED SPECS FOR SHOWER PAN, CONTROL VALVE AND ALL NEW ITEMS. KEY NOTES NEW SHOWER PAN, SURROUND AND CONTROL VALVE O NORTH REVIEWED FOR CODE COMPLIANCE APPROVED OCT 31 2018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA OCT 29 2018 PERMIT CENTER ROOM BUILD -OUT COURTYARD SEATAC SEATAG, 'HASH I NGTON PERMIT SET 10-26-2018 Robert Evenson Associates Architects AIA Architecture Planning Interior Space Planning 6249 SW Canyon Court Portland, Oregon 97221 503-221-0890 #4527 REGISTERED ARC I'Cr OBERTS.EVENSON STATE OF WASHINGT M Cry �► /r 500 Washington Avenue South, Suite 3000 !\J11\Y/11 Minneapolis, MN 55415 Bus: (612) 395.7000 Fax: (612) 395-7002 DEVELOPING REAL ESTATE FOR PEOPLE, BUSINESS & COMMUNITIES Registration: Date: IO-26-2OI8 Reg. No • Drawn By: JASON GRUHN Checked By: Project Manager: ROBB GULNER Dote: OCT. 26, 2015 Revisions i Project N o. XX-XXXX S heet Title OVERALL PLAN 4 ENLARGED PLANS S heet No. A1.0 1 6 5RD -STH FLOOR OVERALL PLAN SCALE: 3/32" = 1'-0" 4 IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII1111111IIIIIIIIIIIIIIIIIIIIII111IIIIIIIIIIIII 111111111111111111111111111111111111111111111111 _k o 000 IIIII1 0 i 1 L -A A 2 1 II 111111IIIIII1111IIIIIIIIIIII IIa- a0 0 0 — �FI111111 0 A- 3D-STH FLOOR DEMO PLAN - TYPICAL AT ALL GUEST ROOMS AA22.0j SCALE: 3/6" = I'—O" GENERAL NOTES I. GENERAL CONTRACTOR 15 TO COORDINATE ALL TRADES FOR THEIR REQUIRED DEMOLITION WORK. 2. DASHED LINES INDICATE WALLS, DOORS AND OTHER ITEMS TO BE REMOVED, UNLESS NOTED OTHERWISE. S. PATCH AND REPAIR ALL EXISTING CEILINGS, PARTITIONS, AND FLOORS DISTURBED FOR NEW WORK AND FINISH. 4. REMOVE FROM SITE A5 SOON A5 PRACTICABLE DEMOLISHED MATERIALS, DEBRIS, AND RUBBISH. DO NOT ACCUMULATE DEBRIS ON THE FLOOR OR AT THE SITE. 5. PATCH AND REPAIR HOLES IN EXISTING GYP BD PARTITIONS AFTER REMOVAL OF EQUIPMENT, MECHANICAL AND ELECTRICAL DEVICES AND OUTLETS, ATTACHMENTS, FURNISHINGS, ETC. DEMO KEY NOTES Di REMOVE EXISTING TUB, SURROUND AND CONTROL VALVE AND PREPARE AREA FOR NEW SHOWER PAN AND NEW CONTROLS. 4 IIIIIIIIIIII111111111IIIIII111111IIIII1111II11111111IIIIIIIIIIIIIIIIIIIIIIIIIII 111111111111111111111111111111111111111111111111 11 1111111111111111111111111111114. 000 --\ - 000 0 - -A A A- 3R-STH FLOOR FLOOR PLAN - TYPICAL AT ALL GUEST ROOMS A2.O / SCALE: 3/6" = I'-0" GENERAL NOTES I. ALL WORK TO BE COMPLETED - TYPICAL AT EACH GUEST BATHROOM. REPLACE EXISTING TUB WITH NEW SHOWER PAN. 2. SEE ATTACHED SPECS FOR SHOWER PAN, CONTROL VALVE AND ALL NEW ITEMS. KEY NOTES NEV' SHOWER PAN, SURROUND AND CONTROL VALVE NORTH ! REVIEWED FOR CODE COMPLIANCE APPROVED OCT 31 2018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA OCT 292018 PERMIT CENTER ROOM BUILD -OUT COURTYARD SEATAC SEATAG, JNASH I NGTON PERMIT SET 10-26-2018 Robert Evenson Associates Architects AIA Architecture Planning Interior Space Planning 6249 SW Canyon Court Portland, Oregon 97221 503-221-0890 N4527 Re: RT S. EVENSON STATE OF WASIIIIl aT 3 C S M 500 WashingtonMN Av55415 enue South, Suite 3000 Minneapolis, Bus: (612) 395-7000 Fax: (612) 395-7002 DEVELOPING REAL ESTATE FOR PEOPLE, BUSINESS & COMMUNITIES Registration: Date: IO-26-2OI8 Reg. No . Drawn By: JASON GRUHN Checked By: Project Manager: ROBB GULNER Dote: OCT. 26, 2016 Revisions Project No. XX-XXXX Sheet Title SRD - STH FLOOR PLANS Sheet No. A2.0