Loading...
HomeMy WebLinkAboutPermit PG18-0137 - TACO BELL - REPLACING FIXTURES, ADJUSTING LOCATION OF FIXTURESTACO BELL 16350 WEST VALLEY HWY PGI 8-0137 Parcel No: Address: r City of Tukwila a Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov PLUMBING/GAS PIPING PERMIT 2523049083 Permit Number: PG18-0137 16350 WEST VALLEY HWY Project Name: TACO BELL Issue Date: 11/29/2018 Permit Expires On: 5/28/2019 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender Name: Address: NWR REALTY LLC 18815 139TH AVE NE C/O NORTHWEST RESTUARANTS WOODINVILLE, WA98072 ANTHONY MYERS 191lSVVCAMPUS DR#489,FEDERAL WAY, WA, 98023 ANTHONY MYERS PLUMBING 19l1SVVCAMPUS DR489'FEDERAL WAY, WA, 98023 ''' Phone: (253) 255-6360 Phone: (253) 255-6360 Expiration Date: 12/9/2019 DESCRIPTION OF WORK: REPLACING FIXTURES, ADJUSTING LOCATION OF FIXTURES Valuation af Work: $5'00000 Water District: TUKW|LA Sewer District: TUKWILA Fees Collected: $208.45 Currerit Codes adopted by the City of Tukwila: nternational BuUdirig Code Edition: International Residential Code Edition: Internationat Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center AuthozedSignatue: 2015 2015 2015 2015 2015 National Electricat Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 20172017 2015 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and.a:, ee to the conditions attached to this permit. Signatu Print Name: Date: l� -� 8j7 K This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall) be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. AH hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 gauge. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 8004 GROUNDWORK 1900 PLUMBING FINAL � 1 8005 ROUGH -IN PLUMBING CITY OF TUKi � "A Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov f Plumbing/Gas Project No.. Date Application Accepted: Date Application Expires: (For office use dnly) ermit No. RI (6/001 PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: t 35 U 1,/c, �({ Tenant Name: f' t 0 13"„'1 PROPERTY OWNER Company Name: / liter /-5 UrYt Address: iq//5W GL'^7 US dr lib, Name: Address: J 1, sCA) ()04,--pv5 Address: City: re�c?ci iN/p/ tate:, City: State: Zip: CONTACT PERSON — person receiving all project communication Company Name: / liter /-5 UrYt Address: iq//5W GL'^7 US dr lib, City: F-coperq tuA 1 State: /4 /, Zip:C,C�„ 2.7 �J' Address: J 1, sCA) ()04,--pv5 W 11 S ? City: re�c?ci iN/p/ tate:, Zip: ] ©23 Phone:2s3 2 s- Fax: Email: King Co Assessor's Tax No.: Suite Number: Floor: New Tenant: ❑ Yes 0.. No PLUMBING CONTRACTOR INFORMATION Company Name: / liter /-5 UrYt Address: iq//5W GL'^7 US dr lib, City: F-coperq tuA 1 State: /4 /, Zip:C,C�„ 2.7 �J' Phone: 25'3 2_c.;5�3aJFax: Contr Reg No.:Apili ons Pl3Cfii07Exp Date: 77 j Tukwila Business License No.: Valuation of Project (contractor's bid price): $ 5� OD O I Scope of Work (please provide detailed information): ie l Ce C I >c v res l c(0)\i}-74 i /1 al �vret \*11bQ) vre SU\ :x I Building Use (per Intl Building Code): Occupancy (per Int'I Building Code): Utility Purveyor: Water: H:\Applications\Forms-Applications On Line \2011 Applications\Plumbing Permit Application Revised 8-9-11.docx Revised: August 2011 bh Sewer: Page 1 of 2 Indicate type of plumbing fixtures and/oi., , piping outlets being installed and the quantity, ow: Fixture Type Type, Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain I Shower, sigle head trap Sinks 2. Rain water system — per drain (inside building) Grease interceptor for commercial kitchen (>750 gallon capacity) Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Fixture Type Qty Bidet Drinking fountain or water cooler (per head) I Lavatory Urinal r7 �^ Water heater and/or vent Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial I Wash fountain Water closet r7 �^ Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets Fixture Type Qty Dental unit, cuspidor Floor drain I Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 IYER Q ' OR3D AGENT: Signat / Print Name: fC44-e m l./ -C'S Mailing Address: J C+ l ( S t`) CO yip v S a, H: ApplicationsWorms-Applications On Line \2011 Applications\Plumbing Permit Application Revised 8-9-11 Arica Revised: August 2011 bh Date: Day Telephone: 5 3 z5 s— G 3C--) fPde,,ty (.,vAi U2-3 City State Zip Page 2 of 2 DESCRIPTIONS ACCOUNT 1 QUANTITY PG18-0137 Address: 16350 WEST VALLEY HWY Apn: 2523049083 4 FEES PAID BY RECEIPT: R16512 1, 0 Date Paid: Wednesday, January 16, 2019 Paid By: ANTHONY MYERS PLUMBING Pay Method: CASH Printed: Wednesday, January 16, 2019 8:19 AM 1 of 1 Y STEM S DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $168.45 P618-0137 Address: 16350 WEST VALLEY HWY Apn: 2523049083 $168.45 Credit Card Fee $4.91 Credit Card Fee R000.369.908.00.00 0.00 $4,91 PLUMBING $155.71 8000.322.100.00,00 0.00 $123,42 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 =EMI TECHNOLOGY FEE $7.83 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R15933 R000.322.900.04.00 0.00 MIN= $168.45 Date Paid: Thursday, November 29, 2018 Paid By: ANTHONY MEYERS Pay Method: CREDIT CARD 041700 Printed: Thursday, November 29, 2018 12:17 PM 1 of 1 YSTEMS (Th CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA 0017340000802374464500 Date: 11/29/2018 12:16:51 PM CREDIT CARD SALE VISA CARD NUMBER: **********9274 K TRAN AMOUNT: $168.45 APPROVAL CD: 041700 RECORD #: 000 CLERK ID: jazzel X {CARDHOLDER'S SIGNATURE) I AGREE TO PAY THE ABOVE TOTAL AMOUNT ACCORDING TO THE CARD ISSUER AGREEMENT (MERCHANT AGREEMENT IF CREDIT VOUCHER) Thank you! Merchant Copy Page 1 of 2 https://classic.convergepay.eomNirtualMerchant/transaction.do?dispatchMethod=printTr... 11/29/2018 Page 2 of 2 CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA Date: 11/29/2018 12:16:51 PM CREDIT CARD SALE VISA CARD NUMBER: **********9274 K TRAN AMOUNT: $168.45 APPROVAL CD: 041700 RECORD #: 000 CLERK ID: jazzel Thank you! Customer Copy http s : //classic . convergepay. com/V irtualMerchant/transacti on. do?di spatchMetho d=printTr... 11 /29/20 1 8 eceipt Number .p R15874 DESCRIPTIONS ACCOUNT PermitTRAK $40.00 PG18-0137 Address: 16350 WEST VALLEY HWY Apn: 2523049083 $40.00 PLUMBING $40.00 PERMIT ISSUANCE BASE FEE PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R15874 R000.322.100.00.00 R000.322.103.00.00 0.00 0.00 $0.86 $39.14 $40.00 Date Paid: Monday, November 19, 2018 Paid By: ANTHONY MYERS Pay Method: CASH Printed: Monday, November 19, 2018 12:39 PM 1 of 1 SYSTEMS INSPECTION RECORD Retain a copy with permit ECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 te) 0137 Project: Type of Inspection: Add s: I Idclif V74A-L1 Date Called: SpecialInstructions: Date Wanted: . m. p.m. Requester: Phone No: »pproved per applicable codes. Corrections required prior to approval. COMMENTS: r, '41i,A14207,Ni A—L Inspector: Date: 5-26 ,433. REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 P6 VS 03'7 Project: Type of Inection: Address: 1(g5S27 t35-1 VALLI Date ailed: Special Instructions: D e Wanted: 7- a. .., P.m. Requester: —ro WV Phone No: 3 ba 2-fi &S-11-1. EJApproved per applicable codes. Corrections required prior to approval. COMMENTS: ofia,J6t6 Inspector: Date: RE!NSPtTIN FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit ON NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION eP4 6 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project: eMA--- Type of Inspection: 43i-4)01411dt- Address: I (9350 1.4eSt \MU -eV Date a led: Special Instructions: / Date Wa ted: a.m. I -31-11 P.m. Requester: ON1 431, ef,i Phone No: '253 z5,5 65to ElApproved per applicable codes. XCorrections required prior to approval. COMMENTS: OW ra00400 .e.ga i& Veqn- V11 c9/ rkfr /2eNtsfeAd )$ Ao ie,SIL- 1"t4•411 i2c1/443t1 jct-ilAtLin rt -6 Inspector: Date: 3/ 2101? REINSPECTION FEE RE UIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection, INSPECTION RECORD Retain a copy with permit P# /6 0/37 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: MO gea--- Type of Inspection: i• Address:, .5V A/O?' 1//e4z37 fitli Date Called: special Instructions: liCA4v40 t tb/1-4 /g ., 6ate Wanted: a. . kj7—/5 P. • Requ,c-b-,0 Phone Ns: _ 56-a 0) c - 6J-1 I Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: Date: i7. REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedute reinspection, WEIRetain a copy with permit INSPECTION RECORD CTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: 1-4ap aa -e-- Type of Inspection: Address: ib, 00 hifikkr. t44. -12y /4/ Date Called: Special Instructions: Date Wanted: J/-37-/6 C2L...n. p.m. Requester: Phone No: El] Approved per applicable codes. Corrections required prior to approval. COMMENTS: R-- iLizeie4 k/ Picow• ao, Inspector: Date: it .117.7 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. PENT GOORD COPr_' PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG18-0137 DATE: 12/17/18 PROJECT NAME: TACO BELL SITE ADDRESS: 16350 WEST VALLEY HWY Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # X Revision # 1 after Permit Issued DEPARTMENTS: Building Division Public Works Fire Prevention Structural Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) REVIEWER'S INITIALS: DATE: 12/20/18 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required Required (corrections entered in Reviews) Approved with Conditions Denied (ie: Zoning Issues) DUE DATE: 1/17/19 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg Ej Fire 1=1 Ping 1=1 PW Staff Initials: 12/18/2013 I "N PERMIT cur° COPC1 PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG18-0137 DATE: 11/19/18 PROJECT NAME: TACO BELL SITE ADDRESS: 16350 W VALLEY HWY X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: aM OCi q1/0\t46 Building Division if)( tC6 Public Works Fire Prevention Structural PRELIMINARY REVIEW: Not Applicable (no approval/review required) REVIEWER'S INITIALS: Planning Division Permit Coordinator DATE: 11/20/18 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required Denied (corrections entered in Reviews) (ie: Zoning Issues) Approved with Conditions DUE DATE: 12/18/18 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 11 Fire Ping PW Staff Initials: 12/18/2013 PROJECT NAME: 1(tL) ' SITE ADDRESS: 1,63,50 W VaLI \Awl PERMIT NO: 1)G 1 °v- ©137 ORIGINAL ISSUE DATE: lc ->-q -/ Si REVISION LOG REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INIT S 1 t�--��--t lvg.. -lf�1R Summary of Revision: r -e of to 3 c ow,r y,,,,.. I. s k p rce s,.k i a� wets s,k. Received by: at b r ,C, /1/-.6--\ REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: t2(1 77/66 Plan Check/Permit Number: P6 ) — 0 1 3 7 ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # ►► Revision # I after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner ❑ Deferred Submittal # e QeL/( Project Name: // / Project Address: /6-5SC) %. V / e1, //&t.7 Contact Persona,7Y -r � je ,S / Phone Number: '253 2 ( 6)6o Summary of Revision: C I/1 G ✓79 e e ckr - c -t- io c c 4'Q --C , , ‘,.1_,-- S i /< t Q i -Ne r 51‘!I K , G !,-1' hQ,1Cil4JQ 5A s'',4/c' RECEIVED CITY Of iUKWIL DEC 17 2018 PERMIT CENTER Sheet Number(s): "Cloud" or highlight all areas of revision including date o revision Received at the City of Tukwila Permit Center by: a --Entered in TRAKiT on W:tPermtt Center\TempiatestForms\Revision Submittal Forndoc Revised August 20 i 5 ANTHONY MYERS PLUMBIN9-- Washington State Department of Labor & Industries How Espanol Contact_ Safety & Health Claims & Insurance Search L&I Page 1 of 2 I AZ Index Help My LAI Workplace Rights Trades & Licensing ANTHONY MYERS PLUMBING Owner or tradesperson MYERS, ANTHONY LEE Principals MYERS, ANTHONY LEE, OWNER SUMMERFORD, APRIL TASHON, SPOUSE WA UBI No. 603 141 473 1911 SW CAMPUS DRIVE 489 FEDERAL WAY, WA 98023 253-255-6360 KING County Business type Individual License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties PLUMBING License no, ANTHOMP8940Z Effective — expiration 09/09/2011— 12/09/2019 Bond Western Surety Co Bond account no 63245958 $6,000.00 Received by L&I Effective date 06/26/2017 06/19/2017 Expiration date Until Canceled Bond history Insurance Nationwide Mutual Ins Co $1,000,000.00 Policy no. ACPGL03009007070 Received by L&I Effective date 09/26/2018 09/19/2018 Expiration date 09/19/2019 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings Cause no 14-2-14626-4SEA Dismissed Help us improve https://seeure.lni.wa.gov/verify/Detail.aspx?UBI=603141473&LIC=ANTHOMP8940Z&SAW= 11/29/2018 ANTHONY MYERS PLUMBING Complaint filed by STATE OF WASHINGTON Complaint date 05/29/2014 Complaint against bond(s) or savings 100236669 Complaint amount $1,998.63 L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp No active workers' comp accounts during the previous 6 year period. Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health No inspections during the previous 6 year period. Page 2 of 2 e? Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=603141473&LIC=ANTHOMP8940Z&SAW= 11/29/2018 1 RI ato 4 RI IL' 1 ,�,�1�,\\."\\\-7) \\t1 'S'S\\ �::�y�Al\\:\ilt V 11i�.La\i a.LYc•U1 \\�yi.\\\\\yl<\7\- H tt �LU�YY LU 91' T N H�tt 17. I \\\1 I\\\V I,\\\V `\\`I 1•. �\\\�}`j h\\� 1 h\\\ 51 t\\\ N t\ t.\1LY -�..� tL)11y t. \\\\\\\\� fCC'\Cc,'\\\\\\ \ P-:k. , 7 7ll\t\\Zli \ t I,\\\\\\\\\\\\\\\\\\\\\\\\\y 1.1` \\\\\\\\\\\\\\\\\\\\\\\\ L\\\%\,:\\\1 I,\\\\\\\\\ i. r\\\\\\\\\\ \ \\\\\\\\\Y t\ LY tiij CiiU/ L. U \ \\\\\\\\\\\\\\\\\\\\\\\\\) rm ,:\\1 r17,%71„ F, 9, vr', ,7 9/I Li'''—'71,/;) F:siiis.:147,r,HI/// I /I/„��z�i e4i 4 lTL/4 T;0 ciri1/Y/ a////) ii,/Gi/, Lv_J ( .1 L/L/J L2% U3 w 2A h \\\\\\ \\1,\\I` I I I \/ I I c\\\\` 2R _Jr= = == = = = P. 15 RI t11 T \`\\ \ I�1 I,\\\ \\ \ \\i ��,t\llif-r7\111‘611:Lij".` i TYP. TYP. 3'-10" e-s-tTe-k-k,-c e-e1 \\\\\\\\\\\\ c) by 6'-4X" kl \\*.\\\\\\\\\\\\`1 \ \\\\\\\\ ',\\\\\\\\\, \\\\\ �\11.aL �iwiLtiv CRP 66 1-1 REVISIONS No changes shall be made to the scope of work witnout prior approval of the Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review. REVIEWED FOR CODE COMPLIANCE APPROVED DEC 202018 City of Tukwila BUILDING DIVISION DEMOLITION FLOOR PLAN 1/4"=1'-0" A 4 4 i TYPICAL EXISTING EXTERIOR WALL: 2x6 WOOD STUDS @16" O.C. w/ 1/2" PLYWOOD (EXP 1) SHEATHING. TYPICAL EXISTING INTERIOR WALL TO REMAIN: 2x4 WOOD STUDS @16" 0.C. (U.N.O.) DEMO ITEMS AS INDICATED (SEE KEY NOTES) A. INSPECT INTERIOR AND EXTERIOR WALLS. REPLACE ANY DAMAGED SUBSTRATE WALLS ETC. INSPECT DINING ROOM WINDOWS & WALLS BELOW WINDOWS FOR EVIDENCE OF MOISTURE DAMAGE & IMPROPERLY INSTALLED FLASHING. VERIFY WITH OWNER. B. ROOF RECOMMENDATIONS: INSPECTION OF EXISTING ROOF BY QUALIFIED ROOFER IS RECOMMENDED. REPLACE ROOF IF WARRANTED. VERIFY ALL ACTIONS WITH OWNER. C. SEE SITE PLAN FOR ANY SITE DEMO WORK. D. POS, SECURITY, SAFE, DRINK SYSTEM AND FRUTISTA MACHINE SHALL BE TEMPORARILY RELOCATED PER STORE MANAGERS DIRECTION, BY AUTHORIZED TECHNICIANS. OWNER SHALL COORDINATE. SEE 3RD PARTY SCOPE OF WORK. REMODEL IMAGE (RI) 1 RI REMOVE ALL DINING AREA SEATS, TABLES, TRASH ENCLOSURES, DIVIDER WALLS & DRINK STATION. 2 RI REMOVE ALL EXISTING TILE FLOORING & COVE BASE IN DINING AREA, CUSTOMER AREA, CORRIDOR, WOMEN'S RESTROOM & MEN'S RESTROOM. REMOVE EXISTING THERMOSTATS ASSOCIATED WITH REMOVED ROOFTOP UNITS. PATCH STUCCO/EIFS AS REQUIRED. MATCH TEXTURE. REMOVE EXISTING RESTROOM DOORS AND FRAMES. REMOVE FRONT COUNTER AND KNEE WALL. NOT USED. NOT USED. NOT USED. REMOVE EXISTING DRINK TABLE, PEPSI AND ICE MACHINES. SAVE PEPSI AND ICE MACHINES FOR REINSTALLATION. NOT USED. 12 RI PATCH CONCRETE SLAB AND CORE HOLES AS NEEDED (I -3—FTD REMOVE EXISTING WALL TILE & SUBSTRATE IN DINING ROOM, RESTROOM AND CORRIDOR 14 RI REMOVE AND REPLACE: EXISTING SINKS, TOILETS, URINAL & ACCESSORIES FOR INSTALLATION OF NEW TILE. 15 R PROTECT EXISTING EQUIPMENT FROM DUST AND DEBRIS. crap SAFE TO BE RELOCATED Till) REMOVE EXISTING MENU BOARD, SAVE FOR REINSTALLATION. 18 R REPAIR WALL DAMAGE WHERE TILE AND TILE BASE ARE REMOVED. (19 RD POS REGISTERS SHOULD NOT BE DISCONNECTED FROM NETWORK UNLESS PAR TECHNICIAN IS PRESENT. RELOCATE DURING COSTRUCTION. 0 RI EXISTING SUBSTRATE TO BE REMOVED BELOW EXISTING WINDOWS TO INSPECT FRAMING FOR DAMAGE. REPLACE IF REQUIRED. REMOVE WINDOW FRAME AND GLAZING. EXISTING TOWER TO REMAIN. PATCH AND REPAIR FINISH. 2 RI P P. p•1 C4 R EXISTING FIRE EXTINGUISHER CABINET TO REMAIN. DEMO CUP HOLDER. EXISTING FLOOR SINK TO BE REMOVED. 6R DEMO PORTION OF WALL. A RAME TO REMAIN. VERIFY STOREFRONT DOOR AND THRESHOLD COMPLIES WITH ADA REQUIREMENTS. REPLACE IF NECESSARY. CUSTOMER TOUCH POINT (CT) REMOVE EXISTING WALK-IN COOLER/FREEZER AND SHELVING. REMOVE EXISTING BAG -IN -BOX. SAVE FOR REINSTALLATION. REMOVE EXISTING DRIVE THRU POS COUNTER. REMOVE EXISTING HAND SINK AND ACCESSORIES. CAP PLUMBING IN WALL/ UNDER SLAB. SAVE HAND SOAP/SANITIZER DISPENSERS FOR REINSTALLATION. REMOVE EXISTING HAND SINK AND ACCESSORIES. SAVE HAND SOAP/SANITIZER DISPENSERS FOR REINSTALLATION. REMOVE EXISTING DUAL LINE. SAVE EXISTING DUAL LINE MOUNTED EQUIPMENT FOR REINSTALLATION. C REMOVE EXISTING FRUTISTA MACHINE. SAVE FOR REINSTALLATION ON NEW CART. REMOVE EXISTING MOP SINK AND FAUCET. PREPARE FOR INSTALLATION OF NEW. 8 C REMOVE EXISTING DRIVE-THRU WINDOW. MODIFY OPENING AS REQUIRED FOR INSTALLATION OF NEW CEP 14C AiedeAk. GPD GROUP Professional Corporation 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 ADDENDUM #2 12.01.17 A ADDENDUM #3 12.10.18 A A A A A A CONTRACT DATE: 05.10.17 BUILDING TYPE: M70H-EXP PLAN VERSION: MAY 2017 SITE NUMBER: STORE NUMBER: 2017088.36 TACO BELL 16350 W. VALLEY HIGHWAY TUKWILA, WA 98188 CUT NEW DOOR OPENING IN EXTERIOR WALL. INSTALL NEW HEADER PER RECEIVED STRUCTURAL DRAWINGS. CITY OF TUKWILA REMOVE EXISTING REAR TOWER. REMOVE EXISTING EXTERIOR DOOR. MODIFY OPENING PER NEW WORK AND DEC 17 2018 STRUCTURAL DRAWINGS. n REMOVE EXISTING SHELVING UNIT. RETURN TO OWNER. PERMIT CENTER o L-13" REMOVE EXISTING FRP AND FLOOR TILE IN BACK OF HOUSE. PREPARE FOR INSTALLATION EOF NEWIDOCUMENT LOCATION OF EXISTING EQUIPMENT PRIOR TO EXPLORER NOT USED. NOT USED. NOT USED. RE VISION N�___ REMOVE EXISTING PREP SINK AND WALL MOUNTED SHELVING. SAVE FOR REINSTALLATION. RECORD EXISTING WATER PIPING SIZES FOR SIZING OF NEW PIPING. SEE SHEET P1.0 FOR ADDITIONAL INFORMATION. REMOVE EXISTING POWERSOAK SINK AND WALL MOUNTED SHELVING. SAVE FOR REINSTALLATION. Taco M7OH DEMO FLOOR PLAN DEMOLITION LEGEND F DEMOLITION NOTES MODIFY EXISTING FLOOR SINK AS REQUIRED FOR INSTALLATION OF NEW OR RELOCATED PLUMBING FIXTURE. SEE SHEET P1.0 FOR ADDITIONAL INFORMATION. DEMOLITION KEY NOTES PLOT DATE: 12-12-18 FINISH DIMENSION 0 ao REV REVIEWED FOR CODE COMPLIANCE APPROVED DEC 20`010 City of Tukwila BUILDING DIVISION FLOOR PLAN 1/4"=1'-0" 11. TYPICAL EXISTING WALL /.•///!// ///i ///. "///. TYPICAL NEW INTERIOR WALL: 2x4 WD STUDS (2X6 WHERE NOTED) AT 16" O.C. W/ 1/2" GYP. BD. SUBSTRATE U.O.N. USE MOISTURE RESISTANT GYP. BD. BEHIND ALL CERAMIC WALL TILE. U.O.N. ACCEPTABLE ALTERNATE: METAL STUDS IN LIEU OF WOOD STUDS. TYPICAL PARTIAL HEIGHT WALL: 2x4 WD STUDS AT 16" O.C. W/ 1/2" GYP. BD. SUBSTRATE U.O.N. ACCEPTABLE ALTERNATE: METAL STUDS IN LIEU OF WOOD STUDS. TYPICAL EXTERIOR WALL: 2x6 STUDS @ 16" O.C. w/ 1/2" EXTERIOR GRADE SHEATHING. WALL STUDS SHALL BE CONTINUOUS. DECOR: A. SEE A2.0 FOR SEATING PLAN AND DETAILS. B. SEE A7.0 FOR FLOOR FINISHES. C. SEE A8.0 - A8.2 FOR WALL FINISHES. D. SEE A7.1 FOR CEILING FINISHES. GENERAL: A. DRAWINGS ARE BASED UPON WOOD FRAMING. UTILIZATION OF METAL STUDS ON NON -BEARING INTERIOR PARTITIONS, BULKHEADS AND SOFFITS IS ACCEPTABLE. B. ALL ATTACHMENTS MADE THROUGH E.I.F.S. SHALL BE BUSHED TO PREVENT DAMAGE TO THE FINISH. C, ALL PENETRATIONS THROUGH E.I.F.S. SHALL BE SEALED USING MFR'S. APPROVED METHOD. DIMENSIONS: A. DIMENSIONS THAT ORIGINATE FROM EXISTING ELEMENTS OF THE BUILDING ARE FROM FACE OF FINISH. ALL OTHER DIMENSIONS ARE TO FACE OF STUD U.O.N. REFER TO FOUNDATION PLAN FOR FACE OF CONC. DIMENSIONS. B. DIMENSIONS NOTED AS "CLEAR" OR "HOLD" ARE MIN. REQ'D. NET CLEARANCE FROM FACE OF WALL / WAINSCOT FINISH. VERIFY FINAL EQUIPMENT SIZES W/ VENDOR PRIOR TO INT. WALL FRAMING. WINDOWS / DOORS: A. SEE SCHEDULE FOR WINDOW AND DOOR TYPES. B. ALL DOOR AND WINDOW OPENING DIMENSIONS ARE TO ROUGH OPENING. FINISH SUBSTRATES: A. PROVIDE 1/2" THICK CEMENTITIOUS BD. FROM FLOOR SLAB TO 12"A.F.F. MIN. IN LIEU OF GYP. BD. AT ALL WALLS EXCEPT SHEARWALL SURFACES, U.O.N. B. ALL JOINTS, GAPS OR SPACES LEADING TO ALL HOLLOW OR INACCESSIBLE SPACES SHALL BE SEALED WITH "NSF INTERNATIONAL" APPROVED SEALANTS. REMODEL IMAGE (RI) 1 RI PATCH STUCCO OR E.I.F.S. C2—R-D PROTECT KITCHEN EQUIPMENT DURING CONSTRUCTION . 3 R EXISTING ELECTRICAL MAIN SWITCH BOARD. REFER TO ELECT. DWGS. 4 RI NOT USED. CONSTRUCT PLYWOOD DUST BARRIER WITH LOCKING SWING GATE TO PROTECT KITCHEN DURING CONSTRUCTION. NEW PARTIAL HEIGHT WALL. TOP OF WALL TO BE AT 3'-3" A.F.F. HOLD NEW WINDOW TO THIS SIDE OF EXISTING WINDOW. EXISTING TOWER TO REMAIN. PATCH AND REPAIR EXISTING E.I.F.S. / STUCCO FINISH. REPLACE EXISTING WINDOW WITHE RECTANGULAR WINDOW. SEE A1.1 & A4.1 REPLACE SUBSTRATE AS REQUIRED. REPOSITION FLOOR SINK AS SHOWN. NEW INTERIOR WALL. REPLACE CLOSET DOOR AND FRAME. REAR TOWER, PATCH AND REPAIR EXISTING E.I.F.S. / STUCCO FINISH. 6" PVC CHASE FROM 12" A.F.F. TO ABOVE CEILING. EXTEND 3" THROUGH WALL. 6" PVC CHASE THROUGH WALL AT 12" A.F.F. 17 RI EXISTING FIRE EXTINGUISHER CABINET TO REMAIN. ADA NOTES (AD) NEW INTERIOR WALL. CUSTOMER TOUCH POINT (CT) (.1...0) NEW WALK-IN COOLER/ FREEZER. INSTALL 1" E.I.F.S. FINISH DIRECTLY TO EXTERIOR OF COOLER. ROOF AND COPING BY MANUFACTURER. (2-6) INSTALL NEW E.I.F.S. WHERE TOWER HAS BEEN REMOVED. INSTALL NEW DRIVE-THRU WINDOW. MODIFY EXISTING OPENING AS REQUIRED. SEE SHEET A2.0. INSTALL NEW H.M. DOOR AND FRAME. SEE SHEET A1.1. INFILL WALL. CONSTRUCTION TO MATCH EXISTING. INSTALL NEW HAND SINK. SEE PLUMBING DRAWINGS. INSTALL NEW MOP SINK. SEE PLUMBING DRAWINGS. INSTALL NEW FRP-1 WALL FINISH RO H-IUT : O. cam► (1110 4111, REPOSITION FLOOR SINK AS SHOWN. REINSTALL EXISTING PREP SINK AND SHELVING. 11 C INSTALL NEW POWERSOAK SINK AND SHELVING SEE A2.0. A RECt:$VED CITY OF 1 UKINIL, .DEC 17 2018 PERMIT CENTE AhAi • Aleffiktip, GPD GROUP Professional Corporation 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 A ADDENDUM #2 12.01.17 A ADDENDUM #3 12.10.18 A A A A A A A CONTRACT DATE: 05.10.17 BUILDING TYPE: M70H-EXP PLAN VERSION: MAY 2017 SITE NUMBER: STORE NUMBER: 2017088.36 TACO BELL 16350 W. VALLEY HIGHWAY TUKWILA, WA 98188 VAC® BELL M7OH EXPLORER FLOOR PLAN NOT USED NTs 2 WALL LEGEND F FLOOR PLAN NOTES D EY NOTES PLOT DATE: 12-12-18 <T-121 <T-122> r<T-771>1 1 -761,* n D-804> <D-581> <D-581> ENTRY D-703 2)1 D-733 J <D-581> <D-581> 0D-581> i r<D-647> D-620>(2) (H) D-655> NO. QTY G.C. INST. ITEM DESCRIPTION MFR. & MODEL NUMBER PLUMB ELECT GAS REMARKS BID NO.L S-375 1 X SELF SERVE DRINK COUNTER 72" CARTER HOFFMAN #CH3-TDS72N55 TOP OF COUNTER @ 34" MAX. RI S-375 S-443 1 X DISPENSE -RITE #TB-TLO '3D' LID AND STRAW DISPENSER RI S-443 S-459 1 FRUTISTA CART WST1306YA RI S-459 S-481 1 X CUP DISPENSER A.J. ANTUNES #DACS50 RI S-481 K-490 2 X FRONT COUNTER SHELVING 18" x 24" x 24" (2 TIER) ISS #WST440Y UNDERCOUNTER SHELVING RI K-490 L-049 1 X INTERIOR MENU BOARD PACKAGE STRATACACHE LG 49 DISPLAY X RI L-049 - 4 X ACCESSIBLE SIGNAGE (1) MEN'S, (1) WOMEN'S, (2) EXIT AD - N-146 2 X LAVATORY FAUCET SLOAN #SF-2350 X OWNER PROVIDED RI N-146 B-101 1 X SECURITY DOOR LOCKNET #DU3670R52VED RIGHT HAND REVERSE CT B-101 B-140 1 X DRIVE-THRU WINDOW QUICKSERV #SC-4030BR G.C. TO PROVIDE TRANSOM - CLEAR ANODIZED CT B-140 B-290 2 X PAPER TOWEL DISPENSER BOBRICK #B-262 SURFACE MTD. CT B-290 B-405 2 X WASTE BASKET RUBBERMAID SLIM JIM #3541 (GREY) CT B-405 , ENTRY D-623>(6) CUSTOMER AREA III ?I'I'P1 NO. B-599 L-150 K-525 K-602 K-699 N-062 N-071 N-208 P-362 QTY 1 1 6 2 5 2 1 1 1 1 N-043 1 K-221 1 I B-405 --J <S-275> B-140> G.C. INST. ® ITEM DESCRIPTION X MOP SINK STATION X SECURITY DOOR DANGER SIGN X SHELVING UNIT 18" X 48" X 76" (5 TIER) X SHELVING UNIT 18" X 36" X 86"H (5TIER) X SHELVING UNIT 18" X 60" X 74"H (5 TIER) X HAND SINK (KITCHEN) X MOP SINK FAUCET X MOP SINK 24"X24" FLOOR MOUNT SINK X DUAL LINE, 157" READY TO ACCEPT EVO CABINETS X 3-COMP POWER SOAK 102"L x 31 "D (R TO L) X 3 COMP. SINK WORKSTATION 96" TRACK OFFICE KITCHEN OFFICE MFR. & MODEL NUMBER ISS #WST806Y ADVERCO#ADVCUSTOM ISS #WST1613Y ISS #WST238Y ISS #SU186075Y AERO #HSK-A T&S #B-2465 AERO MANUF. CO., INC. #3MP-2121-6/1P DELFIELD #TB000P92 (DUKE OPTIONAL) METCRAFT #PS6750 ISS #DS-1F oo —0 U ° I ItLi ,II IIIKK-525)iI 1' , III, <K-525 <K-602> PLUMB X X X X X X GAS ELECT X WAILK}IN FRWER REVIEWED FOR CODE COMPLIANCE APPROVED DEC 202018 City of Tukwila BUILDING DIVISION GENERAL NOTES: G.C. SHALL PROVIDE A CLEAR SILICONE SEAL JOINT AT ALL PERMANENTLY MOUNTED EQUIPMENT, COUNTERS AND CEILING GRID THROUGHOUT THE ENTIRE STORE. MASKING TAPE SHALL BE USED ON JOINTS EXCEEDING 1/4" TO PROVIDE A COVED CORNER. REMARKS ORDERED DIRECT FROM YRFS WALK IN COOLER 15"W x 17"L- 10"x14", FRONT TO BACK x 5"D, INCL. FAUCET W/.5 GPM AERATOR, BASKET, KNEE VALVE REFER TO C/A8.3 INCLUDES (2) 24"X36" WALL PANELS W/ PRE-RINSE,CLICK&CLEAN SYSTEM & (2) T & SB-2466 F WALL TRACK SHELVING BID CT CT CT CT CT CT CT CT CT CT AUCETS SEATING AND EQUIPMENT PLAN 1/4"=11-0" NO zai B-599 L-150 K-525 K-602 K-699 N-062 N-071 N-208 P-362 N-043 K-2214 A SYM. QTY. ITEM <D-581> 7 PLANK SETTEE - 48" <D-620> 42 RETRO CHAIR - 18" <D-623> 12 BARREL BAR STOOL - 29" <D-640> 1 SERVICE COUNTER - TOP @ 34" MAX. <D-646> 1 CONDIMENT CART - RECTANGULAR <D-647> 1 WASTE ENCLOSURE - SINGLE <D-648> 1 WASTE ENCLOSURE - DOUBLE <D-655> 2 WB HUB TABLE - 72" SYM. QTY. ITEM <D-720> 6 24" X 19" TABLE TOP - PLYWOOD <D-721> 2 24" X 42" ADA TABLE TOP - PLYWOOD <D-723> 4 24" X 42" TABLE TOP - PLYWOOD <D-731> 3 24" X 48" TABLE TOP - PLYWOOD <D-733> 1 24" X 48" ADA TABLE TOP - PLYWOOD <D-804> 1 EXTERIOR WASTE ENCLOSURE - SINGLE <T-120> 8 16"X18" EXTERIOR BENCH <D-658> <D-700> <D-703> 1 6 20 WB HUB TABLE (ADA) - 48"L x 30"H 22" X 22" X 28.5"H FREE STANDING TABLE BASE 22" X 5.5" X 28.5"H FREE STANDING TABLE BASE <D-750> 50'-6" WINDOW SILL <D-753> 95'-6" WAINSCOTING <D-755> 45' CHAI R RAI L 2 16"X48" EXTERIOR BENCH <T-122> 4 16"X60" EXTERIOR BENCH 2 TUUCI 10'X10' BAY MASTER MAX UMBRELLA 2 TUUCI 9"X9" IN -GROUND BASE PLATE 0 QTY. ITEM REMARKS ®2 1 FRAMED ART - EMOJIS SEE A8.0 FOR LOCATION ®2 1 FRAMED ART - MASH UP 1 SEE A8.0 FOR LOCATION ®2 1 FRAMED ART - MASH UP 2 SEE A8.0 FOR LOCATION 1. "HOLD" DIMENSIONS ARE FROM FACE OF FINISH. 2. G.C. TO CONFIRM "HOLD" DIMENSIONS WITH EQUIPMENT MFR /VENDOR. 3. TILE CHIPPING AROUND CORE DRILL HOLES FOR SEATING WILL NOT BE ACCEPTED. 4. ALL DIMENSIONS FOR SEATING / CORE DRILL PLAN SHALL BE FROM FACE OF GYP BD. 5. VERIFY ALL DIMENSIONS WITH SEATING VENDOR PRIOR TO INSTALLATION. 6. REFER TO SC SHEETS FOR SCOPE OF WORK RESPONSIBILITIES. 7. SEE INTERIOR ELEVATIONS A8.0-A8.1 FOR LOCATION OF OWNER SUPPLIED ARTWORK. 8. NOT USED 9. (H) - SYMBOL DENOTES A HIGH TABLE OR DINING COUNTER WITH STOOLS 10, ALL SOLID SURFACES TO BE PROPERLY SEAMED PER MFRS SPECIFICATIONS 11. PAINT UNDERSIDE OF SERVICE COUNTER WITH WHITE GLOSS PAINT. AND PROVIDE METAL ANGLE LEDGER FOR END OF COUNTER IF VENDOR DOES NOT PROVIDE ONE. 6 SYMBOL DENOTES A HANDICAP ACCESSIBLE TABLE. REMODEL IMAGE (RI) SERVICE COUNTER. INSTALL NEW DIGITAL MENU BOARDS. CORNER GUARD. SEE DETAIL 8/A6.0. REINSTALL FRUITISTA MACHINE ON NEW CART. NOT USED HIGH CHAIR BY OWNER. NOT USED, 8 R NOT USED. 9 RI FRAMED ARTWORK. SEE ELEVATIONS SHEET A8.0 FOR SIZE AND LOCATION. RELOCATE TEA URN AND/OR BREWER AS SHOWN. INSTALL UNDER COUNTER CUP DISPENSER WITH ANGLED BRACKETS. NOT USED. KITCHEN - NO MODIFICATIONS EXCEPT AS NOTED. c4 R. REWORK EXISTING POWER FOR POS ITEMS IF NECESSARY. NOT USED. NOT USED. HOLES FOR POS CASH REGISTER POWER AND DATA LINE SHOULD BE FIELD CUT BY GC PRIOR TO POS SETUP (TYP). REINSTALL THE SAFE BELOW THE EXPEDITE SECTION OF THE SERVICE COUNTER. SEE DETAIL C/E1.0. NOT USED. 0 RI REINSTALL EXISTING PEPSI AND ICE MACHINES ON NEW TABLE. ADA NOTES (AD) Aeirde.A. GPD GROUP Professional Corporation 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 10 ADDENDUM #1 09.01.17 A ADDENDUM #2 12.01.17 A ADDENDUM #3 12.10.18 A A A A A CONTRACT DATE: 05.10.17 BUILDING TYPE: M70H-EXP PLAN VERSION: MAY 2017 SITE NUMBER: STORE NUMBER: 2017088.36 TACO BELL 16350 W. VALLEY HIGHWAY TUKWILA, WA 98188 PROVIDE TACTILE EXIT SIGN AT EGRESS DOOR PER 'TACTILE SIINCE VE'E) DETAIL ON ADA1.0 WHEN EXISTING IS NOT PROVIDED. CITY OF TUKWILA O2 A) 36" MIN. CLEAR COUNTERTOP REQUIRED PER ADA. MAINTAIN A MINIMUM 3'-0" CLEAR PATH OF EGRESS. DEC 1" 2018 30" x 48" CLEAR FLOOR SPACE FOR HANDICAP SEATING PQ TN. PRMIT QCIEMTER CUSTOMER TOUCH POINT (CT) 4161 REINSTALL SOAP AND HAND SANITIZER DISPENSERS. QC. RELOCATE EXISTING BAG -IN -BOX SYSTEM. RELOCATE SYRUP / WATER LINES AS REQUIRED. 3 C REINSTALL EXISTING EQUIPMENT ON NEW PREP LINE. 4 C INSTALL STAINLESS STEEL CORNER GUARD AT PERIMETER OF DRIVE-THRU WINDOW. NOT USED. NOT USED. 6 REINSTALL EXISTING PREP SINK AND SHELVING. INSTALL NEW 3-COMP SINK AND SHELVING. NEW STAINLESS STEEL SPLASH GUARD. Taco M7OH EXPLORER SEATING AND EQUIPMENT PLAN SEATING PACKAGE (TOTAL SEATS = 681NT.) ARTWORK SCHEDULE SEATING PLAN NOTES C KEY NOTES P #° ( PLOT DATE: 12-12-18 WALL LAVATORY UPRIGHT SUPPORT FLOOR MOUNT WELDED BASE PLATE W/ 1/2" 4x4 (4) HILTI KWIK BOLT II OR EQUAL FINISH FLOOR LAVATORY SUPPORT N.T.S. H T1/2" TEMPERED WATER TO LAVATORY SHUT-OFF VALVE of (TYP) THERMOMETER �MV 1 NI CHECK VALVE (TYP) 1/2" LINE DOMESTIC CW 1 1 — + I -- I DOMESTIC HW TEMPERING VALVE N.T.S. G 1►7 cl TRUEBRO'HANDI-LAV-GUARD 2' & TRUEBRO TRAP COVER45... MODEL #102W MOLDED VINYL PIPE INSULATION KIT OR EQUIVALENT. BARRIER FREE LAVATORY BAR. FREE LAV. PIPE SHROUD N.T.S. F PIPE OR SIMILAR ELEMENT SURFACE PENETRATION SEALANT COVER PLATE Step 1 Step 2 Step 3 NOTE: ALL FLOOR, WALL, CEILING AND ROOF PENETRATIONS SHALL PROVIDE NO GREATER THAN A 1/4" OPENING AT THE PENETRATION. IF THE OPENING IS GREATER THAN 1/4" THEN THE OPENING SHALL BE SEALED WITH ONE OF THE FOLLOWING APPROVED SEALERS: 1) NP-1 by Sonneborn Corp. 2) Geocel 3) Rustoleum Industrial Grade Sealant or 4) Bondaflex PUR 25. If the opening is visible to customers then an NSF approved stainless cover plate (escutcheon) shall be installed. TYP. PENETRATION SEAL DETAIL FOR QUARRY TILE J FILL WITH GROUT NOTE: ALL FLOOR SINKS MUST BE 1/2" ABOVE TILE FLOOR AS SHOWN ABOVE FLOOR SINK DETAIL N.T.S. 1. 1 2'-1" x r 1:31\-(HS 1 0 C1� DINING ROOM RENOVATION KITCHEN RENOVATION 1A 3A FD UR RESTROOM RENOVATION 2A WC WC PLUMBING PLAN 1/4"=1'-0" SOIL AND WASTE PIPE SHALL SLOPE 2% MINIMUM, UNLESS OTHERWISE NOTED OR REQUIRED BY CODE. 2. ALL VALVES, SHOCK ARRESTORS OR OTHER EQUIPMENT SHOWN IN WALLS OR ABOVE NON -ACCESSIBLE CEILING SHALL BE INSTALLED BEHIND AN ACCESS PANEL. 3. PRIOR TO COMMENCING WORK ON THIS PROJECT, CONTRACTOR SHALL VERIFY DEPTH, SIZE, LOCATION AND CONDITION OF ALL EXISTING UTILITIES IN FIELD BEFORE STARTING WORK. SHOULD CONDITIONS EXIST OTHER THAN THOSE INDICATED WHICH WOULD CAUSE THE DESIGN TO BE ALTERED, CONTRACTOR SHALL NOTIFY OWNER IMMEDIATELY. 4. CONTRACTOR SHALL COORDINATE INSTALLATION OF PLUMBING WORK WITH ALL OTHER TRADES SO AS TO AVOID UNNECESSARY DELAY OR INTERFERENCES. CONTRACTOR TO REVIEW ARCHITECTURAL AND EQUIPMENT SHEETS. 5. ALL PLUMBING WORK AND MATERIALS SHALL BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE STATE & LOCAL ORDINANCES & REGULATIONS HAVING JURISDICTION. CONTRACTOR SHALL OBTAIN ALL APPROVALS REQUIRED FROM REGULATING AGENCIES BEFORE STARTING WORK. ALL PLUMBING WORK & MATERIALS SHALL MEET THE REQUIREMENTS OF THE LATEST EDITIONS OF THE LOCAL PLUMBING CODE, UNLESS OTHERWISE REQUIRED BY THE DEPARTMENT OF BUILDING SAFETY. OBTAIN & PAY FOR ALL PERMITS, FEES & INSPECTIONS REQUIRED BY GOVERNING AUTHORITIES. ALL PIPING TO BE CONCEALED UNLESS NOTED OTHERWISE. 6. THE EQUIPMENT ROUGH -INS AS SHOWN ARE BASED UPON AVAILABLE INFORMATION. HOWEVER, IN SOME INSTANCES, THE OWNER OR SUPPLIER MAY SUBSTITUTE OR THE EQUIPMENT ITEM MAY VARY FROM WHAT IS SHOWN, THEREFORE, THE CONTRACTOR SHALL VERIFY ALL CRITICAL DIMENSIONS WITH THE OWNER PRIOR TO CONSTRUCTION. FAILURE OF THE CONTRACTOR TO VERIFY THESE DIMENSIONS SHALL PLACE THE RESPONSIBILITY FOR ANY SUBSEQUENT RELOCATION DIRECTLY ON THE CONTRACTOR. 7. INSTALL SHUTOFF VALVES ON ALL HOT AND COLD WATER LINES TO FIXTURE OR APPLIANCE. ALL EXPOSED WATER AND WASTE LINES SHALL BE CHROME PLATED. 8. ALL VALVES, UNIONS, ETC. TO BE SAME SIZE AS PIPE UNLESS OTHERWISE INDICATED ON DRAWINGS. 9. PROVIDE TEMPERING VALVE AT EACH LAVATORY. SET TEMPERED WATER TEMPERATURE TO 110°F. GENERAL NOTES E ITEM FIXTURE SOIL OR WASTE VENT COLD WATER HOT WATER TEMP'D WATER WASTE FU WATER FU DESCRIPTION MANUFACTURER / MODEL NUMBER WATER CLOSET 4" 2" 1/2" 4 2 WHITE VITREOUS CHINA FLOOR MOUNTED FLUSHOMETER TANK (PRESSURE ASSISTED) TYPE, ELONGATED BOWL, ADA COMPLIANT, 1.1 GPF, WITH OPEN FRONT SEAT LESS COVER, OLSENITE #95 OR EQUIVALENT. FLUSHOMETER TANK: SLOAN FLUSHMATE OR EQUAL. PROVIDE TANK COVER LOCKS. FLUSH LEVERS SHALL BE RIGHT HAND OR LEFT HAND AS REQUIRED TO CORRESPOND WITH ACCESS FROM WIDE SIDE OF STALL. VERIFY FLUSH SIDE REQUIREMENTS AM. STD. "CADET' / MODEL: 2467.100 KOHLER "HIGHLINE" / MODEL: K-3519 (WC 1 LAVATORY 1 1/2" 1-1/2" - -- 1/2" 1,0 1.0 WHITE VITREOUS CHINA, WALL HUNG, WITH CONCEALED ARMS SUPPORT, 4" CENTERS, WITH INTEGRAL BACKSPLASH, ADA ACCESSIBLE. FLAT GRID STRAINER. FAUCET: FURNISHED BY OWNER AND INSTALLED BY THE PLUMBING CONTRACTOR. MOTION ACTIVATED FAUCET, ADA COMPLIANT. SEE H/P1.0 FOR LAV SUPPORT DETAIL. A.S COMRADE / MODEL 0124.131 L 1 FLOOR DRAIN (3,) 3" 2" -- — 2 -- LIGHT DUTY ADJUSTABLE PVC WITH THREADED ADAPTOR AND 5" DIAMETER NICKEL BRONZE RING AND FASTENED GRATE ZURN / MODEL: FD-2210 (FD 1 ) SIOUX CHIEF 842 OATEY 72000 FLOOR SINK 4" 2" -- -- -- 6 --AND PVC 12" SQUARE FLOOR SINK, 8" DEEP, WITH ALUMINUM OR PVC DOME STRAINER LOOSE SET PVC SLOTTED TOP GRATE. JOSAM / MODEL: JPFS4-PVC (FS 1 ) ZURN / MODEL: FD-2370-PV4-DS-F MIXING VALVE "" -" 1/2" 1/2" ----LEONARD --CHECK THERMOSTATIC, 125 P516, 200VF BRONZE BODY, STAINLESS STEEL PISTON LINER, VALVES SIZE PER PIPE CONNECTIONS. ASSE 1070 COMPLIANT. HYDROTEK SERIES HBL SERIES 270 (MV 1 � URINAL 2" 1-1/2" 3/4" -- -- 4 5 WHITE VITREOUS CHINA, WALL HUNG, TOP INLET, ADA COMPLIANT, 1.0 GPF, WITH WALL HANGER. FLUSH VALVE: SLOAN ROYAL 186-1, ZURN Z6003 AV-WSI OR DELANEY DL-F452. AM. STD. "LYNBROOK" / MODEL:6601.012 (UR 1 ) KOHLER "FRESHMAN" / MODEL:K-4989-T CRANE "NEW COLBURN" / MODEL: 4992 HAND SINK 1-1/2" 1-1/2" -- -- 1/2" 2 1.5 S-1: STAINLESS STEEL HAND SINK, WALL HUNG, INCLUDES A 6" GOOSENECK STAINLESS. FAUCET W/FOOT VALVE PER DETAIL I/P1.0. BRAIDED WATER LINES. AERO #HS-MOD (HS 1 ) -- MOP SINK 3" 2" 1/2" 1/2" -- 3 3 MOP SINK: AERO - 3MP-2121-6 W/ 48" HIGH S.S LEFT SIDE AND BACK -SPLASH. FURNISHED BY OWNER, INSTALLED BY GC. FAUCET: T&S #B2465, WITH VACUUM BREAKER, FURNISHED BY OWNER, INSTALLED BY GC. -- C S 2 -- - 3-COMP. SINK INDIRECT "" 1/2" 1/2" -- -- 3 SINK, FAUCET, 1.48 GPM NOZZLE, DRAIN, & POWER SOAK STANDARD — ."6-0 iOT` ." ." .00\r" A `"- Id PSWE" SOAK •S6750 / UFPC ITEM# E30970124 ©© -- /( A /- `� W..."-/ i► 1/2" H.W.— CONNECT TO EXISTING MINIMUM 1/2" C.W. AND H.W. MAIN WATER RISER 1/2" T.W.--'if 1-1/2" CONNECT TO EXISTING TEMPERED WATER WATER RISER L�1 CONNECT TO EXISTING 3" VENT Lee,,,_-1-1/2" 2" CONNECT TO EXISTING 4" MAIN SANITARY RISER 5 CONNECT TO EXISTING 3" VENT 2" CONNECT TO EXISTING MINIMUM 3" MAIN SANITARY RISER 1/2" C.W.—" WATER RISER CONNECT TO EXISTING 3/4" C.W. MAIN 3/4" J _ CONNECT TO EXISTING 3/4" C.W. MAIN WATER RISER REVIEWED FOR CODE COMPLIANCE APPROVED DEC 202018 City of Tukwila BUILDING DIVISION CONNECT TO i EXISTING 3" VENT CONNECT TO EXISTING 4" MAIN SANITARY RISER W CONNECT TO EXISTING 3" VENT f2° CONNECT TO EXISTING 4" MAIN SANITARY RISER ADA NOTES (AD) 400 A EXISTING LAVATORY TO BE REMOVED FOR RESTROOM RENOVATIONS AND REPLACED WITH NEWIL-1) IN LOCATION SHOWN ON PLANS. SEE ARCH. SHEETS FOR EXACT LOCATION OF NEW FIXTURE. INSTALL NEW WATER, SANITARY, AND VENT PIPING FOR NEW L-1 AS NECESSARY FOR COMPLETE INSTALLATION. FIELD VERIFY EXISTING TEMPERING VALVE ON WATER SUPPLY MEETS ASSE 1070, PROVIDE/REPLACE WITH MV-1 AS NECESSARY TO MEET CURRENT CODE REQUIREMENTS. SEE LAVATORY SUPPORT DETAIL H/P1.0. PROVIDE BARRIER FREE LAV PIPE SHROUD ON ALL PIPING UNDER LAV SEE DETAIL F/P1.0. SEE DETAIL 'J' THIS SHEET FOR WALL PENETRATIONS. EXTEND AND CONNECT 1-1/2" VENT TO MINIMUM 3" VENT THRU ROOF. EXTEND AND CONNECT 1/2" T.W. TO EXISTING MIXING VALVE. EXTEND AND CONNECT 2" DRAIN LINE TO EXISTING MINIMUM 4" SANITARY SEWER. FIELD VERIFY EXACT LOCATIONS PRIOR TO START OF ANY WORK. EXISTING WATER CLOSET TO BE REMOVED AND REPLACED WITH NEW (WC-1) PER ADA REG'S. CONTRACTOR SHALL INSTALL NEW WATER, SANITARY, AND VENT PIPING AS REQUIRED, SEE ARCH. SHEETS FOR EXACT LOCATION OF NEW FIXTURE. FLUSH VALVE TO HAVE HANDLE ON WIDE SIDE FOR STALL (PER ADA REQUIREMENTS) COORDINATE ALL PLUMBING WORK WITH G.C. SEE DETAIL 'J' THIS SHEET FOR WALL PENETRATIONS. EXTEND AND CONNECT 3" VENT TO MINIMUM 3" VENT THRU ROOF. EXTEND AND CONNECT 1/2" C.W. TO EXISTING 3/4" MAIN C.W. LINE. EXTEND AND CONNECT 4" DRAIN LINE TO EXISTING MINIMUM 4" SANITARY SEWER. FIELD VERIFY EXACT LOCATIONS PRIOR TO START OF ANY WORK. EXISTING FLOOR DRAIN. FIELD VERIFY EXACT LOCATION PRIOR TO START OF WORK. RAISE TO LEVEL OF NEW FLOORING. PROVIDE AND INSTALL NEW GRATE TO MATCH EXISTING. EXISTING URINAL TO BE REMOVED AND REPLACED WITH NEW (UR-1) PER ADA REG'S. CONTRACTOR SHALL INSTALL NEW WATER, SANITARY AND VENT PIPING AS REQUIRED, SEE ARCH. SHEETS FOR EXACT LOCATION OF NEW FIXTURE. COORDINATE ALL PLUMBING WORK WITH G.C. SEE DETAIL 'J' THIS SHEET FOR WALL PENETRATIONS.EXTEND AND CONNECT 1-1/2" VENT TO MINIMUM 3" VENT THRU ROOF. EXTEND AND CONNECT 3/4" C.W. TO EXISTING 3/4" C.W. MAIN LINE. EXTEND AND CONNECT 2" DRAIN LINE TO EXISTING MINIMUM 4" SANITARY SEWER. FIELD VERIFY EXACT LOCATIONS PRIOR TO START OF ANY WORK. REMODEL IMAGE (RI) 1 R NEW FLOOR SINK. EXTEND AND CONNECT NEW 3" SANITARY LINE TO MINIMUM 3" SANITARY SEWER. CONNECT NEW 1-1/2" VENT TO EXISTING 1-1/2" MINIMUM VENT. FIELD VERIFY EXACT LOCATION PRIOR TO START OF ANY WORK. SEE DETAIL 'I' THIS SHEET. CUSTOMER TOUCH POINT (CT) EXISTING MOP SINK TO BE REMOVED FOR KITCHEN RENOVATIONS AND REPLACED WITH NEWS-2) IN LOCATION SHOWN ON PLANS. SEE ARCH. SHEETS FOR EXACT LOCATION OF NEW FIXTURE. INSTALL NEW WATER, SANITARY, AND VENT PIPING FOR NEW S-2 AS NECESSARY FOR COMPLETE INSTALLATION. EXTEND AND CONNECT 2" VENT TO MINIMUM 3" VENT THRU ROOF. EXTEND AND CONNECT 1/2" C.W. AND H.W. TO EXISTING C.W. AND H.W. LINES. EXTEND AND CONNECT 3" DRAIN LINE TO EXISTING MINIMUM 3" SANITARY SEWER. FIELD VERIFY EXACT LOCATIONS PRIOR TO START OF ANY WORK. EXISTING HAND SINK TO BE REMOVED FOR DINING ROOM AND KITCHEN RENOVATIONS AND REPLACED WITH NEW (HS-1) IN LOCATION SHOWN ON PLANS. SEE ARCH. SHEETS FOR EXACT LOCATION OF NEW FIXTURE. INSTALL NEW WATER, SANITARY, AND VENT PIPING FOR NEW HS-1 AS NECESSARY FOR COMPLETE INSTALLATION. FIELD VERIFY EXISTING TEMPERING VALVE ON WATER SUPPLY MEETS ASSE 1070, PROVIDE/REPLACE WITH MV-1 AS NECESSARY TO MEET CURRENT CODE REQUIREMENTS. SEE DETAIL J THIS SHEET FOR WALL PENETRATIONS. EXTEND AND CONNECT 1 1/2" VENT TO MINIMUM 3" VENT THRU ROOF. EXTEND AND CONNECT 1/2" T.W. TO EXISTING MIXING VALVE. EXTEND AND CONNECT 2" DRAIN LINE TO EXISTING MINIMUM 3" SANITARY SEWER. FIELD VERIFY EXACT LOCATIONS PRIOR TO START OF ANY WORK. NEW FLOOR SINK. EXTEND AND CONNECT NEW 3" SANITARY LINE TO MINIMUM 3" SANITARY SEWER. CONNECT NEW 1-1/2" VENT TO EXISTING 1-1/2" MINIMUM VENT, FIELD VERIFY EXACT LOCATION PRIOR TO START OF ANY WORK. SEE DETAIL 'I' THIS SHEET. 4 C 1 NEW FLOOR SINK. EXTEND AND CONNECT NEW 3" SANITARY LINE TO MINIMUM 3" SANITARY SEWER. CONNECT NEW 1-1/2" VENT TO EXISTING 1-1/2" MINIMUM VENT. FIELD VERIFY EXACT LOCATION PRIOR TO START OF ANY WORK. SEE DETAIL 'I' THIS SHEET. 7C APPROXIMATE LOCATION OF EXISTING FLOOR SINK. EXISTING FLOOR SINK TO REMAIN. FIELD VERIFY EXACT LOCATION PRIOR TO START OF ANY WORK. EXISTING HAND SINK TO BE RELOCATED FOR DINING ROOM AND KITCHEN RENOVATIONS TO LOCATION SHOWN ON PLANS. SEE ARCH. SHEETS FOR ) EXACT LOCATION OF RELOCATED FIXTURE. INSTALL NEW WATER, SANITARY, COMPLETE INSTALLATION. PROVIDE WITH MV-1. SEE DETAIL J THIS SHEET AND VENT PIPING FOR RELOCATED HAND SINK AS NECESSARY FOR FOR WALL PENETRATIONS. EXTEND AND CONNECT VENT WITH SAME SIZE ASS C VE>� EXISTING TO MINIMUM 3" VENT THRU ROOF. EXTEND AND CONNECT 1/�,0 v" ��i.i���al�r'EL AND H.W. TO NEW MIXING VALVE. EXTEND AND CONNECT DRAIN LINE SAME SIZE AS EXISTING TO MINIMUM 3" SANITARY SEWER. FIELD VERIFY EXACT LOCATIONS PRIOR TO START OF ANY WORK. D )c 17 2018 NEW 3 COMPARTMENT SINK (S-3) TO BE PLACED IN LOCATION SHOWN ON O PLANS FOR DINING ROOM AND KITCHEN RENOVATIONS. SEE ARCH. SHE 3EFLIT CENT WI FOR EXACT LOCATION OF NEW S-3. INSTALL NEW WATER, SANITARY, ANTE VENT PIPING FOR NEW S-3 AS NECESSARY FOR COMPLETE INSTALLATION. SEE DETAIL J THIS SHEET FOR WALL PENETRATIONS. EXTEND AND CONNECT 1/2" C.W. AND H.W. TO NEW S-3. ROUTE INDIRECT DRAIN LINE TO EXISTING FLOOR SINK. FIELD VERIFY EXACT LOCATIONS PRIOR TO START OF ANY WORK. 40b40,. GPD GROUP Professional Corporation 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 A ADDENDUM #2 12.01.17 A ADDENDUM #3 12.10.18 A A A A A A A CONTRACT DATE: 05.10.17 BUILDING TYPE: M70H-EXP PLAN VERSION: MAY 2017 SITE NUMBER: STORE NUMBER: 2017088.36 TACO BELL EXISTING 1 COMPARTMENT SINK TO BE RELOCATED FOR DINING ROOM AND KITCHEN RENOVATIONS TO LOCATION SHOWN ON PLANS. SEE ARCH. SHEETS FOR EXACT LOCATION OF RELOCATED FIXTURE. INSTALL NEW WATER, SANITARY, AND VENT PIPING FOR RELOCATED 1 COMPARTMENT SINK AS NECESSARY FOR COMPLETE INSTALLATION. SEE DETAIL J THIS SHEET FOR WALL PENETRATIONS. EXTEND AND CONNECT VENT WITH SAME SIZE AS EXISTING TO MINIMUM 3" VENT THRU ROOF. EXTEND AND CONNECT 1/2" C.W. AND H.W. TO RELOCATED FIXTURE. ROUTE INDIRECT DRAIN LINE TO NEW FLOOR SINK. FIELD VERIFY EXACT LOCATIONS PRIOR TO START OF ANY WORK. 16350 W. VALLEY HIGHWAY TUKWILA, WA 98188 EXPLORER PLUMBING PLAN & SCHEDULE PLUMBING FIXTURE SCHEDULE D PLUMBING RISERS N.T.S PLOT DATE: 12-12-18 8 RI 1 RI 1R 7 RI 9R 4 RI 4 RI 9 RI 10 RI 7 RI 10RI 24'-1 %" 1 RI 8 ti 6'-0)" FINISH DIMENSION 0 7'-7X" 8R 1 RD (j�'"A-,�`%�I{. a3,i re 1' .i Yi RlT tea, iccnanicai I Electrical 0,Plumiaing a( Gas Piping City of Tukwila BUILDING DIVISION No changes ,_ REVISIONS_____....... hISIC�n�S__ _ _..... �_ ..._... to thq of work witho!, prior ap pr vn scone a EI_;kfin`I DiViriort NOTE: Revisions will requ.re „ `� new plan subnnt?ar and may include ad ditional plan review Ins FILE C-OPY Permit flo. \c6/ Plan review approvsl is subject to errors and clnicions. Approval of construction documents does the violation of any ado t Qrdi%ls co. ► rt of approved Fi3;• City of Tukwila BUILDING DIVISION NOT USED NTS 2 TYPICAL EXISTING WALL TYPICAL NEW INTERIOR WALL: 2x4 WD STUDS (2X6 WHERE NOTED) AT 16" O.C. W/ 1/2" GYP. BD. SUBSTRATE U.O.N. USE MOISTURE RESISTANT GYP. BD. BEHIND ALL CERAMIC WALL TILE. U.O.N. ACCEPTABLE ALTERNATE: METAL STUDS IN LIEU OF WOOD STUDS. TYPICAL PARTIAL HEIGHT WALL: 2x4 WD STUDS AT 16" O.C. W/ 1/2" GYP. BD. SUBSTRATE U.O.N. ACCEPTABLE ALTERNATE: METAL STUDS IN LIEU OF WOOD STUDS. TYPICAL EXTERIOR WALL: 2x6 STUDS @ 16" O.C. w/ 1/2" EXTERIOR GRADE SHEATHING. WALL STUDS SHALL BE CONTINUOUS. WALL LEGEND DECOR: A. SEE A2.0 FOR SEATING PLAN AND DETAILS. B. SEE A7.0 FOR FLOOR FINISHES. C. SEE A8.0 - A8.2 FOR WALL FINISHES. D. SEE A7.1 FOR CEILING FINISHES. GENERAL: A. DRAWINGS ARE BASED UPON WOOD FRAMING. UTILIZATION OF METAL STUDS ON NON -BEARING INTERIOR PARTITIONS, BULKHEADS AND SOFFITS IS ACCEPTABLE. B. ALL ATTACHMENTS MADE THROUGH E.I.F.S. SHALL BE BUSHED TO PREVENT DAMAGE TO THE FINISH. C. ALL PENETRATIONS THROUGH E.I.F.S. SHALL BE SEALED USING MFR'S. APPROVED METHOD. DIMENSIONS: A. DIMENSIONS THAT ORIGINATE FROM EXISTING ELEMENTS OF THE BUILDING ARE FROM FACE OF FINISH. ALL OTHER DIMENSIONS ARE TO FACE OF STUD U.O.N. REFER TO FOUNDATION PLAN FOR FACE OF CONC. DIMENSIONS. B. DIMENSIONS NOTED AS "CLEAR" OR "HOLD" ARE MIN. REQ'D. NET CLEARANCE FROM FACE OF WALL / WAINSCOT FINISH. VERIFY FINAL EQUIPMENT SIZES W/ VENDOR PRIOR TO INT. WALL FRAMING. WINDOWS / DOORS: A. SEE SCHEDULE FOR WINDOW AND DOOR TYPES. B. ALL DOOR AND WINDOW OPENING DIMENSIONS ARE TO ROUGH OPENING. FINISH SUBSTRATES: A. PROVIDE 1/2" THICK CEMENTITIOUS BD. FROM FLOOR SLAB TO 12" A.F.F. MIN. IN LIEU OF GYP. BD. AT ALL WALLS EXCEPT SHEARWALL SURFACES, U.O.N. B. ALL JOINTS, GAPS OR SPACES LEADING TO ALL HOLLOW OR INACCESSIBLE SPACES SHALL BE SEALED WITH "NSF INTERNATIONAL" APPROVED SEALANTS. FLOOR PLAN NOTES D REMODEL IMAGE (RI) CiFD 4 RI 14R PATCH STUCCO OR E.I.F.S. PROTECT KITCHEN EQUIPMENT DURING CONSTRUCTION . EXISTING ELECTRICAL MAIN SWITCH BOARD. REFER TO ELECT. DWGS. NOT USED. CONSTRUCT PLYWOOD DUST BARRIER WITH LOCKING SWING GATE TO PROTECT KITCHEN DURING CONSTRUCTION. NEW PARTIAL HEIGHT WALL. TOP OF WALL TO BE AT 3'-3" A.F.F. HOLD NEW WINDOW TO THIS SIDE OF EXISTING WINDOW. EXISTING TOWER TO REMAIN. PATCH AND REPAIR EXISTING E.I.F.S. / STUCCO FINISH. REPLACE EXISTING WINDOW WITHE RECTANGULAR WINDOW. SEE A1.1 & A4.1 REPLACE SUBSTRATE AS REQUIRED. REPOSITION FLOOR SINK AS SHOWN. NEW INTERIOR WALL. REPLACE CLOSET DOOR AND FRAME. REAR TOWER. PATCH AND REPAIR EXISTING E.I.F.S. / STUCCO FINISH. 6" PVC CHASE FROM 12" A.F.F. TO ABOVE CEILING. EXTEND 3" THROUGH WALL. 6" PVC CHASE THROUGH WALL AT 12" A.F.F. FLOOR PLAN 1/4"=1'-0" 17 RI EXISTING FIRE EXTINGUISHER CABINET TO REMAIN. ADA NOTES (AD) NEW INTERIOR WALL. RECEIVED CITY OF TUKWILA NOV 19 2018 TER CUSTOMER TOUCH POINT (CT) Q�1 NEW WALK-IN COOLER/ FREEZER. INSTALL 1" E.I.F.S. FINISH DIRECTLY TO EXTERIOR OF COOLER. ROOF AND COPING BY MANUFACTURER. 0-6.-D INSTALL NEW E.I.F.S. WHERE TOWER HAS BEEN REMOVED. �1 INSTALL NEW DRIVE-THRU WINDOW. MODIFY EXISTING OPENING SEE SHEET A2.0. 4 C INSTALL NEW H.M. DOOR AND FRAME. SEE SHEET A1.1. INFILL WALL. CONSTRUCTION TO MATCH EXISTING. 6 C INSTALL NEW HAND SINK. SEE PLUMBING DRAWINGS. �1 INSTALL NEW MOP SINK. SEE PLUMBING DRAWINGS. 8 C INSTALL NEW FRP-1 WALL FINISH THROUGH -OUT B.O.H. E 1 Ii2I=n REVIEWE I CODE COMP APPROV NOV 212 City of Tuk BUILDING DI KEY NOTES OR ANCE Agetitt. GPD GROUP Professional Corporation 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 ® ADDENDUM #2 12.01.17 A A A A A A A CONTRACT DATE: BUILDING TYPE: PLAN VERSION: SITE NUMBER: STORE NUMBER: 05.10.17 M70H-EXP MAY 2017 2017088.36 TACO BELL 16350 W. VALLEY HIGHWAY TUKWILA, WA 98188 11AC0 M7OH EXPLORER FLOOR PLAN PLOT DATE: 12-13-17 rnu ////,r s,;;;� ZL71L u111] \7-7t\\\\`yy1 77) \\\ �k\``�\\7:711(7777y�\�\\ \` y1L\\\\\y}Y�`Tc\ �11 �S T \\ \\ \\\\\ e�.�-rm� m \\\\\ \\\\,\�w\``\\\\1 Z \\\\\\\\\\ \\\\\\\\\\\\\\\\\\\\\\\\\ b\\\\\\\\\\\\\\\\\\\\\\\Y L\\\\\\\\ �;;;\\\.\\'s\'I \\\\\\\\\ \\\\\\\\\\ L\\\\\\\\\\y �\\\\\\\\\\y Lit Li / / / I (FAD i 7RZT1 \\\\\\\ LJ 0,\.\ 11I\\\\},\iti,e ��\\\ \:4,,, L _y J I`\`ii "t\`\\\\\-�\�I�c\�\\\ \`11\`_\...s. I1 ►,\\\\`\\� \-� L\, \\ \\\\I \\ �t \\ \\\\ Ammi Hilt "Mill -j #hilClp3IF RECEIVED CITY OF TUKWILA NOV 19 2018 PERMIT CENTER DEMOLITION FLOOR PLAN 1/4"=11-01' TYPICAL EXISTING EXTERIOR WALL: 2x6 WOOD STUDS @16" O.C. w/ 1/2" PLYWOOD (EXP 1) SHEATHING. TYPICAL EXISTING INTERIOR WALL TO REMAIN: 2x4 WOOD STUDS @16" O.C. (U.N.O.) DEMO ITEMS AS INDICATED (SEE KEY NOTES) A. INSPECT INTERIOR AND EXTERIOR WALLS. REPLACE ANY DAMAGED SUBSTRATE WALLS ETC. INSPECT DINING ROOM WINDOWS & WALLS BELOW WINDOWS FOR EVIDENCE OF MOISTURE DAMAGE & IMPROPERLY INSTALLED FLASHING. VERIFY WITH OWNER. B. ROOF RECOMMENDATIONS: INSPECTION OF EXISTING ROOF BY QUALIFIED ROOFER IS RECOMMENDED. REPLACE ROOF IF WARRANTED. VERIFY ALL ACTIONS WITH OWNER. C. SEE SITE PLAN FOR ANY SITE DEMO WORK. D. POS, SECURITY, SAFE, DRINK SYSTEM AND FRUTISTA MACHINE SHALL BE TEMPORARILY RELOCATED PER STORE MANAGERS DIRECTION, BY AUTHORIZED TECHNICIANS. OWNER SHALL COORDINATE. SEE 3RD PARTY SCOPE OF WORK. REMODEL IMAGE (RI) 1 Rl REMOVE ALL DINING AREA SEATS, TABLES, TRASH ENCLOSURES, DIVIDER WALLS & DRINK STATION. REMOVE ALL EXISTING TILE FLOORING & COVE BASE IN DINING AREA, CUSTOMER 2R .;s •O' U REMOVE EXISTING THERMOSTATS ASSOCIATED WITH REMOVED ROOFTOP UNITS. S IIC e/ SL • Q • T REMOVE EXISTING RESTROOM DOORS AND FRAMES. REMOVE FRONT COUNTER AND KNEE WALL. NOT USED. NOT USED. NOT USED. 10 RI REMOVE EXISTING DRINK TABLE, PEPSI AND ICE MACHINES. SAVE PEPSI AND ICE MACHINES FOR REINSTALLATION. NOT USED. PATCH CONCRETE SLAB AND CORE HOLES AS NEEDED REMOVE EXISTING WALL TILE & SUBSTRATE IN DINING ROOM, RESTROOM AND CORRIDOR REMOVE AND REPLACE: EXISTING SINKS, TOILETS, URINAL & ACCESSORIES FOR INSTALLATION OF NEW TILE. 15 RI PROTECT EXISTING EQUIPMENT FROM DUST AND DEBRIS. 16 RI SAFE TO BE RELOCATED REMOVE EXISTING MENU BOARD, SAVE FOR REINSTALLATION. REPAIR WALL DAMAGE WHERE TILE AND TILE BASE ARE REMOVED. POS REGISTERS SHOULD NOT BE DISCONNECTED FROM NETWORK UNLESS PAR TECHNICIAN IS PRESENT. RELOCATE DURING COSTRUCTION. EXISTING SUBSTRATE TO BE REMOVED BELOW EXISTING WINDOWS TO INSPECT FRAMING FOR DAMAGE. REPLACE IF REQUIRED. REMOVE WINDOW FRAME AND GLAZING. EXISTING TOWER TO REMAIN. PATCH AND REPAIR FINISH. PROTECT EXISTING STOREFRONT & DOOR OR WINDOW & FRAME TO REMAIN. NOT USED. NOT USED. NOT USED. 8 R EXISTING FIRE EXTINGUISHER CABINET TO REMAIN. DEMO CUP HOLDER. EXISTING FLOOR SINK TO BE REMOVED. ADA NOTES (AD) DEMO PORTION OF WALL. VERIFY STOREFRONT DOOR AND THRESHOLD COMPLIES WITH ADA REQUIREMENTS. REPLACE IF NECESSARY. C STeM R O C PIT C REMOVE EXISTING WALK-IN COOLER/FREEZER AND SHELVING. REMOVE EXISTING BAG -IN -BOX. SAVE FOR REINSTALLATION. REMOVE EXISTING DRIVE THRU POS COUNTER. REMOVE EXISTING HAND SINK AND ACCESSORIES. CAP PLUMBING IN WALL/ UNDER SLAB. SAVE HAND SOAP/SANITIZER DISPENSERS FOR REINSTALLATION. REMOVE EXISTING HAND SINK AND ACCESSORIES. SAVE HAND SOAP/SANITIZER DISPENSERS FOR REINSTALLATION. H1 REMOVE EXISTING DUAL LINE. SAVE EXISTING DUAL LINE MOUNTED EQUIPMENT FOR REINSTALLATION. 6 C REMOVE EXISTING FRUTISTA MACHINE. SAVE FOR REINSTALLATI N Ckt ., Q�) REMOVE EXISTING MOP SINK AND FAUCET. PREPARE FOR INSTA L�AcC` 8 C REMOVE EXISTING DRIVE-THRU WINDOW. MODIFY OPENING AS EQUIR'��t'` INSTALLATION OF NEW. 9 C CUT NEW DOOR OPENING IN EXTERIOR WALL. INSTALL NEW H DER P iOV 21 2 STRUCTURAL DRAWINGS. REMOVE EXISTING REAR TOWER. REMOVE EXISTING EXTERIOR DOOR. MODIFY OPENING PER eititlisIANG DIV STRUCTURAL DRAWINGS. 126REMOVE EXISTING SHELVING UNIT. RETURN TO OWNER. eQ�i 1r REMOVE EXISTING FRP AND FLOOR TILE IN BACK OF HOUSE. PREPARE FOR INSTALLATION OF NEW. DOCUMENT LOCATION OF EXISTING EQUIPMENT PRIOR TO T PsRA•YR LO ATISN. A City of Tu 4 U Professional Corporation 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 A ADDENDUM #2 12.01.17 A A A A A A CONTRACT DATE: 05.10.17 BUILDING TYPE: M70H-EXP PLAN VERSION: MAY 2017 SITE NUMBER: STORE NUMBER: 2017088.36 TACO BELL 16350 W. VALLEY HIGHWAY TUKWILA, WA 98188 )R NCE ON MCC) EMIL M7OH EXPLORER DE OLITION LEGEND DEMOLITION NOTES D DOLITION KEY NOTES .00 PLOT DATE: 12-13-17 WALL LAVATORY UPRIGHT SUPPORT ■ FLOOR MOUNT 4x4 WELDED BASE PLATE W/ 1/2" (4) HILTI KWIK BOLT II OR EQUAL FINISH FLOOR LAVATORY SUPPORT N.T.S. H 1/2" TEMPERED WATER TO LAVATORY SHUT-OFF VALVE (TYP) rami.. THERMOMETER �MV 1) iT♦ IN CHECK VALVE (TYP) /f,. '% /% 1/2" LINE DOMESTIC CW (T — + I "" I DOMESTIC HW TEMPERING VALVE N.T.S. G 1 wit TRUEBRO'HANDI-LAV-GUARD 2' & TRUEBRO TRAP COVER MODEL #102W MOLDED VINYL PIPE INSULATION KIT OR EQUIVALENT. BARRIER FREE LAVATORY BAR FREE LAV. PIPE SHROUD N.T.S. F PIPE OR SIMILAR ELEMENT SURFACE PENETRATION SEALANT Step 1 Step 2 Step 3 NOTE: ALL FLOOR, WALL, CEILING AND ROOF PENETRATIONS SHALL PROVIDE NO GREATER THAN A 1/4" OPENING AT THE PENETRATION. IF THE OPENING IS GREATER THAN 1/4" THEN THE OPENING SHALL BE SEALED WITH ONE OF THE FOLLOWING APPROVED SEALERS: 1) NP-1 by Sonneborn Corp. 2) Geocel 3) Rustoleum Industrial Grade Sealant or 4) Bondaflex PUR 25. If the opening is visible to customers then an NSF approved stainless cover plate (escutcheon) shall be installed. TYP. PENETRATION SEAL DETAIL J FOR QUARRY TILE FILL WITH GROUT NOTE: ALL FLOOR SINKS MUST BE 1/2" ABOVE TILE FLOOR AS SHOWN ABOVE FLOOR SINK DETAIL N.T.S. I FS 1 1 RI 2'-1" DINING ROOM RENOVATION 1. SOIL AND WASTE PIPE SHALL SLOPE 2% MINIMUM, UNLESS OTHERWISE NOTED OR REQUIRED BY CODE. 2. ALL VALVES, SHOCK ARRESTORS OR OTHER EQUIPMENT SHOWN IN WALLS OR ABOVE NON -ACCESSIBLE CEILING SHALL BE INSTALLED BEHIND AN ACCESS PANEL. 3. PRIOR TO COMMENCING WORK ON THIS PROJECT, CONTRACTOR SHALL VERIFY DEPTH, SIZE, LOCATION AND CONDITION OF ALL EXISTING UTILITIES IN FIELD BEFORE STARTING WORK. SHOULD CONDITIONS EXIST OTHER THAN THOSE INDICATED WHICH WOULD CAUSE THE DESIGN TO BE ALTERED, CONTRACTOR SHALL NOTIFY OWNER IMMEDIATELY. J 4. CONTRACTOR SHALL COORDINATE INSTALLATION OF PLUMBING WORK WITH ALL OTHER TRADES SO AS TO AVOID UNNECESSARY DELAY OR INTERFERENCES. CONTRACTOR TO REVIEW ARCHITECTURAL AND EQUIPMENT SHEETS. 5. ALL PLUMBING WORK AND MATERIALS SHALL BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE STATE & LOCAL ORDINANCES & REGULATIONS HAVING JURISDICTION. CONTRACTOR SHALL OBTAIN ALL APPROVALS REQUIRED FROM REGULATING AGENCIES BEFORE STARTING WORK. ALL PLUMBING WORK & MATERIALS SHALL MEET THE REQUIREMENTS OF THE LATEST EDITIONS OF THE LOCAL PLUMBING CODE, UNLESS OTHERWISE REQUIRED BY THE DEPARTMENT OF BUILDING SAFETY. OBTAIN & PAY FOR ALL PERMITS, FEES & INSPECTIONS REQUIRED BY GOVERNING AUTHORITIES. ALL PIPING TO BE CONCEALED UNLESS NOTED OTHERWISE. 6. THE EQUIPMENT ROUGH -INS AS SHOWN ARE BASED UPON AVAILABLE INFORMATION. HOWEVER, IN SOME INSTANCES, THE OWNER OR SUPPLIER MAY SUBSTITUTE OR THE EQUIPMENT ITEM MAY VARY FROM WHAT IS SHOWN, THEREFORE, THE CONTRACTOR SHALL VERIFY ALL CRITICAL DIMENSIONS WITH THE OWNER PRIOR TO CONSTRUCTION. FAILURE OF THE CONTRACTOR TO VERIFY THESE DIMENSIONS SHALL PLACE THE RESPONSIBILITY FOR ANY SUBSEQUENT RELOCATION DIRECTLY ON THE CONTRACTOR. 7. INSTALL SHUTOFF VALVES ON ALL HOT AND COLD WATER LINES TO FIXTURE OR APPLIANCE. ALL EXPOSED WATER AND WASTE LINES SHALL BE CHROME PLATED. 8. ALL VALVES, UNIONS, ETC. TO BE SAME SIZE AS PIPE UNLESS OTHERWISE INDICATED ON DRAWINGS. 9. PROVIDE TEMPERING VALVE AT EACH LAVATORY. SET TEMPERED WATER TEMPERATURE TO 110°F. GENERAL NOTES ITEM FIXTURE SOIL OR WASTE VENT COLD WATER HOT WATER TEMP'D. WATER WASTE FU WATER FU DESCRIPTION MANUFACTURER / MODEL NUMBER WATER CLOSET 4" 2" 1/2" 4 2 WHITE VITREOUS CHINA FLOOR MOUNTED FLUSHOMETER TANK (PRESSURE ASSISTED) TYPE, ELONGATED BOWL, ADA COMPLIANT, 1.1 GPF, WITH OPEN FRONT SEAT LESS COVER, OLSENITE #95 OR EQUIVALENT. FLUSHOMETER TANK: SLOAN FLUSHMATE OR EQUAL. PROVIDE TANK COVER LOCKS. FLUSH LEVERS SHALL BE RIGHT HAND OR LEFT HAND AS REQUIRED TO CORRESPOND WITH ACCESS FROM WIDE SIDE OF STALL. VERIFY FLUSH SIDE REQUIREMENTS AM. STD. "CADET' / MODEL: 2467.100 KOHLER "HIGHLINE" / MODEL: K-3519 (WC 1 LAVATORY 1-1/2" 1-1/2" __ -- 1/2" 1.0 1.0 WHITE VITREOUS CHINA, WALL HUNG, WITH CONCEALED ARMS SUPPORT, 4" CENTERS, WITH INTEGRAL BACKSPLASH, ADA ACCESSIBLE. FLAT GRID STRAINER. FAUCET: FURNISHED BY OWNER AND INSTALLED BY THE PLUMBING CONTRACTOR. MOTION ACTIVATED FAUCET, ADA COMPLIANT. SEE H/P1.0 FOR LAV SUPPORT DETAIL. A.S COMRADE / MODEL 0124.131 ( L 1 ) FLOOR DRAIN (3") 3" 2" -- -- -- 2 -- LIGHT DUTY ADJUSTABLE PVC WITH THREADED ADAPTOR AND 5" DIAMETER NICKEL BRONZE RING AND FASTENED GRATE ZURN / MODEL: FD-2210 (..FD 1 SIOUX CHIEF 842 OATEY 72000 FLOOR SINK 4" 2" "" "" -- 6 -- PVC 12" SQUARE FLOOR SINK, 8" DEEP, WITH ALUMINUM OR PVC DOME STRAINER AND LOOSE SET PVC SLOTTED TOP GRATE. JOSAM / MODEL: JPFS4-PVC ZURN / MODEL: FD-2370-PV4-DS-F (FS 1 ) MIXING VALVE -- -- 1/2" 1/2" -- -- _ THERMOSTATIC, 125 P516, 200VF BRONZE BODY, STAINLESS STEEL PISTON LINER, CHECK VALVES SIZE PER PIPE CONNECTIONS. ASSE 1070 COMPLIANT. HYDROTEK SERIES HBL LEONARD SERIES 270 �MV 1 � URINAL 2" 1-1/2" 3/4" '" -- 4 5 WHITE VITREOUS CHINA, WALL HUNG, TOP INLET, ADA COMPLIANT, 1.0 GPF, WITH WALL HANGER, FLUSH VALVE: SLOAN ROYAL 186-1, ZURN Z6003 AV-WSI OR DELANEY DL-F452. AM. STD. "LYNBROOK" / MODEL:6601.012 (UR 1 � KOHLER FRESHMAN / MODEL:K-4989-T HAND SINK 1-1/2" 1-1/2" -- -- 1/2" 2 1.5 S-1: STAINLESS STEEL HAND SINK, WALL HUNG, INCLUDES A 6" GOOSENECK STAINLESS. FAUCET W/FOOT VALVE PER DETAIL I/P1.0. BRAIDED WATER LINES. AERO #HS-MOD __ (HS 1) MOP SINK 3" 2" 1/2" 1/2" __ _ — 3 — — 3 — —. —. MOP SINK: AERO - 3MP-2121-6 W/ 48" HIGH S.S LEFT SIDE AND BACK -SPLASH. FURNISHED BY OWNER, INSTALLED BY GC. FAUCET: T&S #B2465, WITH VACUUM BREAKER, FURNISHED BY OWNER, INSTALLED BY GC. — — A A — — - — w A. A A A �., i.. A w. A -- C S 2 __ __ _ ...� _ A. A ir..r 1/2" T.W. 1-1/2" CONNECT TO EXISTING TEMPERED WATER WATER RISER 5 CONNECT TO EXISTING 3" VENT 1-1/2" CONNECT TO EXISTING 4" MAIN SANITARY RISER CONNECT TO EXISTING 3/4" C.W. MAIN 1/2" C.W.-fir WATER RISER CONNECT TO i EXISTING 3" VENT CONNECT TO EXISTING 4" MAIN SANITARY RISER 3/4" 1-1/2" 1A L 3A (FD J _ CONNECT TO EXISTING 3/4" C.W. MAIN WATER RISER CONNECT TO EXISTING 3" VENT IN( 1 UR) lc) 4 /-2" CONNECT TO EXISTING 4" MAIN SANITARY RISER RESTROOM RENOVATION ADA NOTES (AD) 4A 2A WC 2 Ao WC PLUMBING PLAN 1/4"=1-0" EXISTING LAVATORY TO BE REMOVED FOR RESTROOM RENOVATIONS AND REPLACED WITH NEW (L-1) IN LOCATION SHOWN ON PLANS, SEE ARCH. SHEETS FOR EXACT LOCATION OF NEW FIXTURE. INSTALL NEW WATER, SANITARY, AND VENT PIPING FOR NEW L-1 AS NECESSARY FOR COMPLETE INSTALLATION. FIELD VERIFY EXISTING TEMPERING VALVE ON WATER SUPPLY MEETS ASSE 1070, PROVIDE/REPLACE WITH MV-1 AS NECESSARY TO MEET CURRENT CODE REQUIREMENTS. SEE LAVATORY SUPPORT DETAIL H/P1.0. PROVIDE BARRIER FREE LAV PIPE SHROUD ON ALL PIPING UNDER LAV SEE DETAIL F/P1.0. SEE DETAIL 'J' THIS SHEET FOR WALL PENETRATIONS. EXTEND AND CONNECT 1-1/2" VENT TO MINIMUM 3" VENT THRU ROOF. EXTEND AND CONNECT 1/2" T.W. TO EXISTING MIXING VALVE. EXTEND AND CONNECT 2" DRAIN LINE TO EXISTING MINIMUM 4" SANITARY SEWER. FIELD VERIFY EXACT LOCATIONS PRIOR TO START OF ANY WORK. EXISTING WATER CLOSET TO BE REMOVED AND REPLACED WITH NEW (WC-1) PER ADA REG'S. CONTRACTOR SHALL INSTALL NEW WATER, SANITARY, AND VENT PIPING AS REQUIRED, SEE ARCH. SHEETS FOR EXACT LOCATION OF NEW FIXTURE. FLUSH VALVE TO HAVE HANDLE ON WIDE SIDE FOR STALL (PER ADA REQUIREMENTS)COORDINATE ALL PLUMBING WORK WITH G.C. SEE DETAIL 'J' THIS SHEET FOR WALL PENETRATIONS. EXTEND AND CONNECT 3" VENT TO MINIMUM 3" VENT THRU ROOF. EXTEND AND CONNECT 1/2" C.W. TO EXISTING 3/4" MAIN C.W. LINE. EXTEND AND CONNECT 4" DRAIN LINE TO EXISTING MINIMUM 4" SANITARY SEWER. FIELD VERIFY EXACT LOCATIONS PRIOR TO START OF ANY WORK. EXISTING FLOOR DRAIN. FIELD VERIFY EXACT LOCATION PRIOR TO START OF WORK. RAISE TO LEVEL OF NEW FLOORING. PROVIDE AND INSTALL NEW GRATE TO MATCH EXISTING. EXISTING URINAL TO BE REMOVED AND REPLACED WITH NEW (UR-1) PER ADA REG'S. CONTRACTOR SHALL INSTALL NEW WATER, SANITARY AND VENT PIPING AS REQUIRED, SEE ARCH. SHEETS FOR EXACT LOCATION OF NEW FIXTURE. COORDINATE ALL PLUMBIN G.C. SEE DETAIL 'J' THIS SHEET FOR WALL PENETRATION CONNECT 1-1/2" VENT TO MINIMUM 3" VENT THRU ROOF. CONNECT 3/4" C.W. TO EXISTING 3/4" C.W. MAIN LINE. EXT CONNECT 2" DRAIN LINE TO EXISTING MINIMUM 4" SANIT FIELD VERIFY EXACT LOCATIONS PRIOR TO START OF ANl REMODEL IMAGE (RI) 1 RI NEW FLOOR SINK. EXTEND AND CONNECT NEW 3" SANIT A Y LI CPf Tukwila MINIMUM 3" SANITARY SEWER. CONNECT NEW 1-1/2" VE4ILDI G CIS ISION EXISTING 1-1/2" MINIMUM VENT. FIELD VERIFY EXACT LO TO START OF ANY WORK. SEE DETAIL 'I' THIS SHEET. ITH Professional Corporation 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax: 330.572.2102 flEC i'E.D CITY OF TUKWILA Ivul l Logi PE- :MIT CENTER A ADDENDUM #2 12.01.17 A A A A A A CONTRACT DATE: BUILDING TYPE: D FOR.AN VERSION: E COMPLIA�II�UMBER: Y SEWAIOPROVED WORK. STOFE NUMBER: . NOV 21 2118 05.10.17 M70H-EXP MAY 2017 2017088.36 CUSTOMER TOUCH POINT (CT) EXISTING MOP SINK TO BE REMOVED FOR KITCHEN RENOVATIONS AND REPLACED WITH NEW (S-2) IN LOCATION SHOWN ON PLANS. SEE ARCH. SHEETS FOR EXACT LOCATION OF NEW FIXTURE. INSTALL NEW WATER, SANITARY, AND VENT PIPING FOR NEW S-2 AS NECESSARY FOR COMPLETE INSTALLATION. EXTEND AND CONNECT 2" VENT TO MINIMUM 3" VENT THRU ROOF. EXTEND AND CONNECT 1/2" C.W. AND H.W. TO EXISTING C.W. AND H.W. LINES. EXTEND AND CONNECT 3" DRAIN LINE TO EXISTING MINIMUM 3" SANITARY SEWER. FIELD VERIFY EXACT LOCATIONS PRIOR TO START OF ANY WORK. EXISTING HAND SINK TO BE REMOVED FOR DINING ROOM AND KITCHEN RENOVATIONS AND REPLACED WITH NEW (HS-1) IN LOCATION SHOWN ON PLANS. SEE ARCH. SHEETS FOR EXACT LOCATION OF NEW FIXTURE. INSTALL NEW WATER, SANITARY, AND VENT PIPING FOR NEW HS-1 AS NECESSARY FOR COMPLETE INSTALLATION. FIELD VERIFY EXISTING TEMPERING VALVE ON WATER SUPPLY MEETS ASSE 1070, PROVIDE/REPLACE WITH MV-1 AS NECESSARY TO MEET CURRENT CODE REQUIREMENTS. SEE DETAIL J THIS SHEET FOR WALL PENETRATIONS. EXTEND AND CONNECT 1 1/2" VENT TO MINIMUM 3" VENT THRU ROOF. EXTEND AND CONNECT 1/2" T.W. TO EXISTING MIXING VALVE. EXTEND AND CONNECT 2" DRAIN LINE TO EXISTING MINIMUM 3" SANITARY SEWER. FIELD VERIFY EXACT LOCATIONS PRIOR TO START O A Y WOR . TACO BELL 16350 W. VALLEY HIGHWAY TUKWILA, WA 98188 `IrAG 0 BELL M7OH EXPLORER L L SC E _' LE PLUMBING FIXTURE SCHEDULE D PLUMBING RISERS N.T.S PLOT DATE: 12-13-17