Loading...
HomeMy WebLinkAboutPermit EL18-0804 - LANTERN LANDING - INSTALL SERVICE AND PANELLANTERN LANDING 1233 ANDOVER PARK E ELI 8-0804 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.eov ELECTRICAL PERMIT 3523049084 Permit Number: EL18-0804 1233 ANDOVER PARK E Project Name: LANTERN LANDING Issue Date: 10/1/2018 Permit Expires On: 3/30/2019 Owner: Name: Address: PETERSON MATT 3356 E SHORE DR HOUGHTON HARBOR LLC, SEATTLE, WA, 98112 Contact Person: Name: STUART EDWARDS Address: PO BOX 7059 , BONNEY LAKE, WA, 98391 Contractor: Name: JNM ELECTRIC INC Address: PO BOX 7059 , BONNEY LAKE, WA, 98391 License No: JNMELEI87104 Lender: Name: Address: Phone: (253) 414-5340 Phone: (253) 439-8892 Expiration Date: 9/24/2019 DESCRIPTION OF WORK: INSTALLATION OF (1) 600 AMP SERVICE AND (1) 100 AMP PANEL Valuation of single family: $0.00 Valuation of mf/comm: $65,000.00 Type of Work: TENANT IMP Fees Collected: $1,554.97 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: Date: .:() 2017 2017 2017 2015 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. C Signature: tr G/ ` `! ,A n Date; 0 --) — 7D 1 Print Name: k%� ,AAC C0`( This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: <NONE> PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKW Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TulcwilaWA.gov Electrical Permit No. Project No. Date Application Accepted: Date Application Expires: or o r ce use onl ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 1233 Andover Park East King Co Assessor's Tax No.: Suite Number: NIA Floor: First Tenant Name: Unoccupied J (411-rrll New Tenant: ❑ Yes ®..No PROPERTY OWNER Name: Stuart Edwards Name: Houghton Harbor LLC City: Bonney Lake State: WA Zip: 98391 Address: 3356 East Shore Drive Email: stuart@jnmelectric.com City: Seattle State: WA Zip: 98122 CONTACT PERSON — person receiving all project communication Name: Stuart Edwards Address: PO BOX #7059 City: Bonney Lake State: WA Zip: 98391 Phone: 253-414-5340 Fax: 253-648-3504 Email: stuart@jnmelectric.com ELECTRICAL CONTRACTOR INFORMATION Company Name: JNM Electric,Inc Address: PO Box # 7059 City: Bonney Lake State: WA Zip: 98391 Phone: 253-389-3902 Fax: 253-648-3504 Contr Reg No.: JNMELE187104 Exp Date: 9/24/2019 Tukwila Business License No.; BUS -0995176 Valuation of Project (contractor's bid price): $ 65,000 Scope of Work (please provide detailed information): Installation of (1) 600amp service and (1) 100amp panel Will service be altered? m Yes ❑ No Adding more than 50 amps? ❑ Yes m No Type of Use: Type of work: 9 New 0 Addition 9 Service Change ❑ Remodel 0 Tenant Improvement 9 Low Voltage ❑ Generator 9 Fire Alarm 9 Telecommunication 9 Temporary Service Property Served by: I2I Puget Sound Energy ❑ Seattle City Light W:\Permit Center \ Applications -Handouts \Permit Applications\PDFs\Electrical Permit Application Revised 1-1-17.docx Revised: January 2017 bh Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings (including an attached garage) ❑ Garages, pools, spas and outbuildings ❑ Low voltage systems (alarm, furnace thermostat) $155.91 $83.54 ea $61.05 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $83.54 (no added/altered circuits) ❑ Service change with added/altered circuits $83.54 number of added circuits $12.00 ea ❑ Circuits added/altered without service change $55.69 (up to 5 circuits) ❑ Circuits added/altered without service change $55.69 (6 or more circuits) $7.65 ea ❑ Meter/mast repair $69.62 ❑ Low voltage systems $61.05 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $66.30 ❑ Temporary service (generator) $82.52 ❑ Manufactured/mobile home service $87.98 (excluding garage or outbuilding) ❑ Carnivals $82.21 Number of concessions $11.02 ea Each ride and generator truck $11.02 ea ***EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Si 404/i18 Date: Print Name: Stuart Edwards Day Telephone: (253) 414-5340 Mailing Address: PO Box #7059 Bonney Lake WA 98391 W:U"ermit Center \Applcations-Handouts\Permit Applications \PDFs\Etectricai Permit Revised: January 2017 bh p ion Revised 1-1-17.docx City State Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT I QUANTITY PAID $1,624.59 EL18-0804 Address: 1233 ANDOVER PARK E Apn: 3523049084 $1,554.97 ELECTRICAL $1,495.16 PERMIT FEE MULTI-FAM/COMM R000.322,101.00.00 0.00 $1,196.13 PLAN CHECK FEE R000.345.832.00.00 0.00 $299.03 TECHNOLOGY FEE $59.81- TECHNOLOGY FEE R000.322.900.04.00 0.00 $59.81 EL18-0805 Address: 1233 ANDOVER PARK E Apn: 3523049084 $69.62 ELECTRICAL $66.30 PERMIT FEE MULTI-FAM/COMM I R000.322.101.00.00 0.00 I $66.30 TECHNOLOGY FEE $3.32 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R15437 R000.322.900.04.00 0.00 $3.32 $1,624.59 Date Paid: Thursday, September 20, 2018 Paid By: JNM ELECTRIC INC Pay Method: CHECK 2823 Printed: Thursday, September 20, 2018 12:26 PM 1 of 1 SYSTEMS INSPECTION NO. INSPECTION RECORD Retain a copy with permit -0s-qPERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 Project: /.... if_11.44 kAi 1 C Type of Inspection:g". t AIM. -- Address: 1z33 06 Date Called: Special Instructions: #.429f t et-- , 1... , /XL/ ( 10— - POt_11 PN Date Wanted: 1 a. P• • Requester: g liz41-4)- 0 AI Phone No: jo 4 (17 •?) ( 7735 fig]Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: Inspector: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be pair; at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Fl e, Type of Ingt;n: Address: 44outxpki.e Date Called: Itit cime' .' L. Special nstructions: Date Wanted: a.m. p.m. Requester: Phone No: tiguroved per applicable codes. Jj Corrections required prior to approval. COMMENTS: Fod- Itit cime' .' L. i Set- 1 C ri.:./1- i •/1 .k LC-, (nee- 194"'"e' i't iftCfz"el " Inspector: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 Project: LAkinesit jj Type of Inspectioot‘ SLAii Address: / a,3 0/ Date Called: Special Instructions: Date Wanted: . . Requester: Phone No: ElApproved per applicable codes. El Corrections required prior to approval. COMMENTS: Nr --5 LJ soJruc F04\14103 Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3.7 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: S -612-14C Address: In) tti-P Date Called: Special Instructions: Date Wanted: 0 I 1 4m., 1/4IrK Requester: Phone No: 0 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: T6r1(3‘. kl Inspector: 66‘1k464\ Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. CO NS.IDA I(^ [t!.:IbCAI OISTI111^IOES SOC. +TY •',R 11R8ItiTY Date: June 15, 2018 CED - Kent 20730 72nd Ave S. Kent, WA 98032 Phone: (253)893-7333 JNM Electric Job Name Lantern Landing Quote # 5004546 Bid Date 6/13/18 Submittal Date 6/15/18 REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC SEP 2 7 2018 City of Tukwila BUI DING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED SEP 2 7 2018 City of Tukwila BUILDING DIVISION SEP 2 0 2018 tV6- tY6014- Date: June 15, 2018 OILED cis,U0.1tt^ tltctt.cAL 01M110104t * G. Project Lantern Landing Quote# 5004546 Location Seattle, WA Transmittal CED - Kent 20730 72nd Ave S. Kent, WA 98032 Phone: (253)893-7333 From: Bethany Everly Email: Bethany@CEDSEATTLE.COM ATTACHED WE ARE SENDING YOU 1 COPY OF THE FOLLOWING ITEM: ❑ Drawings ❑ Prints ❑ Plans ❑ Specifications ❑ Information 121 Submittals THESE ARE TRANSMITTED FOR: ❑ Prior Approval 0 Resubmittal for Approval ® Approval 0 Corrections ❑ Approval as Submitted 0 Your Use O Approval as Noted 0 Review and Comment 0 Other: 0 Other: 0 Submitted by ERW LIGHTING + CONT Job e: ER\V LIGHTING + CONTRC Lantern Landing �./ (SEA g Designer: LIGHTWIRE - SEATTLE ) Catalog Numb AL150-NW-G1- Notes: -4-8-BZ Type: A -VE ERWH18-20258 AL150/AL200 AL150-NW-G1-AR AL200-NW-G1-AR 216 2850 40006 147 280 3800 40008 197 18,585 B3 -U0 -G3 126 18.324 B3 -U0 -G3 125 24.382 64-90-04 124 24.139 83-50.03 122 1 wdtiage,ird very b; dpe n; LEL? 1,1:1...:,41( tla lcrward volt spc,if,:dlxr, and arnrAcnl temperalurc Wattage shown is a'er age fol 120V through 277V Input Measured wattage may vary: due to oar iattun put voltage 2 Lumen values based un photor.,etri'. tests C'er`orn:ed u: conipbance with IESNA LM 79 Contact out doorIighting apply: at rot st-phiiips corn f , details or additional tolonnah•.ui Predicted performance derived from LED manufacturer's data and engineering design estimates. based on IESNA LM -80 methodology. Actual experience may vary due to field application conditions L70 is the predicted time when LED performance depreciates to 70% of initial Lumen output. Calculated per IESNA TM21-11 Published L70 hours limited to 6 times actual LED test hours. 25 °C 12OmA 2850mA >68,000 >54 000 77% 25 °C 120mA 3800mA >68,000 >54.000 77% I Predicted performance derived from LED manufacturer's data and engineer ng design estimates. based on IESNA LM -80 methodology Actual experience may vary due to field application conditions 2 L70 is the predicted nme when LED performance depreciates to 70% of initial lumen output 3. Calculated per IESNA TM 21-11. Published L70 hours limited to 6 times actual LED test hours 13.6 I345rnnil ---- 13.6" f 345mnij LUMINAIRE WEIGHT - 14 lbs 16 3 kgj LUMINAIRE EPA 0 40ft` if) 0,1 rn-j _ 00 41' iolOrnrni . 11._l_ ll_Ll..J. _L4 2 3" 73nn,+.l 4 3` E10.,iurnl i J 19 a E.192m^ii .<; 2017 Philips Lighting Holding B V. All rights reserved Philips reserves the right to make changes in specifications and/or to discontinue any product at any time without notice or obligation and will not be liable for any consequences resulting from the use of this publication philips.com/luminaires Stonco_AreaLignt_SpecSheet 08117 page 2of2 POLE DRILL TEMPLATE Philips Lighting North America Corporation 200 Franklin Square Dnve. Somerset. NJ 08873 Tel 855-486-2216 Philips Lighting Canada Ltd 281 Hillmount Rd. Markham. ON, Canada L6C 2S3 Tel. 800-668-9008 Submitted On: Jun 19, 2018 2/2 Index Page Submitted by ERW LIGHTING + CONT Catalog Num Tye: (-- c`riW LIGHTING + CONTRC Job , : d ` e: Lantern Landing Lighting Designer: LIGHTWIRE - SEATTLE (SEATTLE) A1150 -NW -G1- ►"-4-8-BZ Notes: -V E ERWH18.20258 Area light LED AL150/AL200 LED Wattage and Lumen Values ">y;ten: t:o4- . Arge,age Tyr, 3 Ty.. 4 Tera) temp 5y,ten- Lon, Erf,e,y . t+en cPin..c Orderlog Codes LEDs .. ., wattage Output BUGRating .. Output BUGRating i AL150-NW-G1-AR 216 2850 4000K 147 18,585 B3 -UO -G3 126 18.324 B3 -UO -G3 125 AL200-14W-61-AR 280 3800 40008 197 24,382 84 -U0 -G4 124 24.109 83-50-03 122 1 Wattage and Iunl,gn output may ray `nay by due t0 Li:i) morairdSturc•r f;xw. rd volt Spei ifir alv.mi and ar+.ibicnl tel aper iturc Wattage shown to average for 120V through 277V Input Measure=d wattage may vary dun to bar iabo0 in input voltage. 2 Lumen values based on photometric test pertonr,snd v, compliance wan IESNA LM -79 Contact ouldoarlighting applr:anons-i. ohilips rom lot derails or additional InfonnshurI Predicted Lumen Depreciation Data Predicted performance derived from LED manufacturer's data and engineering design estimates. based on IESNA LM -80 methodology. Actual experience may vary due to field application conditions. L70 is the predicted time when LED performance depreciates to 70% of initial lumen output. Calculated per IESNA TM21-11 Published L70 hours limited to 6 times actual LED test hours. Ambient LEO System CsIr. utater 170 per Lumen Maintenance Ternperarure 5 Current Current L70hrs-- ?M21-' •.i 50.000hrs 25 °C 120mA 2850mA >68,000 >54 000 r 77% 25 °C . 120mA 3800mA >68.000 >54.000 - 77% 1. Predicted performance derived from LED manufacturer's data and engineering design estimates. based on IESNA LM -80 methodology. Actual expenence may vary due to field application conditions. 2 L70 is the predicted time when LED performance depreciates to 70% of initial lumen output 3 Calculated per IESNA TM 21-11. Published 170 hours limited to 6 times actual LED test hours. Dimensions I3.6 1345rrnni- — .._.-_.t {_.., ■TS/'■..a-.._.1it i +IXt 'j,t [, 1 el I D+Itl+ rr clil LII LUMINAIRE WEIGHT ;; 14lbs 163kg) LUMINAIRE EPA - 04011' 10 0.1 m- IaUi�[.I,Nall 1.11, 13.6 (345rnml _ 00.41•• (olOnunl tr:IyL Idi, / 1i i'.; ° LI,f I' ;II ' ! I-- 21 _ 164mrn; 3 ;89mm17 t._..-._.- 1 (4 5mrry .... POLE •. w DRILL TEMPLATE 00 875" to22mm1 Ol_1_L 43. 1,10..rnrri ;- - --_.__--,....._ 1.1.L_l.J .l .- ..3 4 14975'... ---- ._..........__..-......._ —J 23.(13inmj _e 2017 Philips Lighting Holding B V Alt rights reserved Philips Lighting North America Corporation Philips reserves the right to make changes in specifications PHILIPS 200 Franklin Square Drive. Somerset, NJ 08873 and/or to discontinue any product at any time without notice Tel Tel 855-486-2216 or obligation and will not be liable for any consequences 11 resulting from the use of this publication • Philips Lighting Canada Ltd. philips.com/luminaires \/ 281 Hillmount Rd. Markham, ON. Canada L6C 253 Tel 800-668-9008 Stonco_AreaLight_SpecSheet 08/17 page 2 01 2 Submitted On: Jun 19, 2018 naex rage Submitted by ERW LIGHTING + CON a -R W LIGHTING + CONTRC Job ' e: Lantem Landing Lighting (SEAngI_ Designer: LIGHTWIRE - SEATTLE Job: Type: Notes: Poles Page 1 of 4 4" Straight Square Steel The Philips Gardco SSS straight steel pole consists of a one-piece square fabricated steel lighting standard. The carbon steel base plate is secured to the shaft with a continuous circumferential weld providing excellent strength and integrity. The poles are finished with an electrostatically applied, thermally cured TGIC polyester powdercoat All poles include anchor bolts, full base cover, hand hole, ground lug and top cap. PREFIX HEIGHT SIZE GAUGE DRILLING FINISH Enter the order code into rhe appropriate box above Note: Philips Gardco reserves the right to refuse a configuration. Not all combinations and con- figurations are valid. Refer to notes below for exclusions and limitations. For questions or concerns, please consult the factory. PREFIX HEIGHT 10' 12' 14' 15' 18' 211" 24' 25' 30' FINISH PP IMP BLP WP NP GV FPGV Prime Painted Bronet Paint Black Paint White Paint Natural Aluminum Paint Galvanized (No Pond Finished Paint over Galvanized (specify color) OC Optional Color Paint Specify RAL designation ex: OC-RA1.7024. SC Special Color Paint Specify. Must supply color chip. SIZE 4" OPTIONS GAUGE 7 1 DRILLING OPTIONS !I _ I wily D2 2Way 02©90 2 Way at 90' D3 3 Way D4 4 Way T2 2 3/8" ODTenon T4 4" ODTenon FES Festoon Outlet AHH Additional Hand Hole For Festoon Outlets andAdditional Hand Holes, indicate height above base and orientation to original hand holt. See Pole Orientation Infomtatian on Page 4. Coupling Indicate size (112', 3/4', f", 1 114", 1 1/2'.) Indicate height above base and orientation to hand hole. See Pak Oriartotaion Information on Page 4. CL Coupling - Internal thread Single Mount Bullhorn Brackets Indicate height above base and orientation to hand holt. See Pole Orientation Information on Page 4. GM -080-19 Single - 1.9" OD GM -080-24 Single - 2.4" OD J4otion Response Provisions GMR Provision for Gardco HID Motion Response System Minimum Pak Height a I8'. Includes a 112" cooping placed 180' to the had hoe, 12' above die pole base, MSM Motion Sensor Mounting Provision for LED Luminaires available with Motion Response Minimum Pole Height is l8'. Includes a special land holt with 112" coupling placed in the cover plate, 180' to the hand hole, 15' above the pole base. Refer to Steal Pole Accessories sheet 79415-26 for additional accessories. 1611 Clovis Railcar Road, San Marcos,TX 711666 (1100) 227-0751 (512) 753-1000 FAX: (512) 753-7155 sitelighting.corn O 2011 Koninkhjiae Philips Electronics N.V. A8 Rights Reserved. Ph'i'lips Gardco reserves dee right to grange materials or modify the design of its product without notification es part of the company's continuing product improvement program. 79415-17/0611 PHILIPS GARDCO Submitted On: Jun 19, 2018 1/4 Index Page Submitted by ERW LIGHTING + CONI c W LIGHTING + CONTRC Job Name: Lantem Landing Eighties Designer: LIGHTWIRE - SEATTLE (SEATTLE) Catalog Num SSS4-20-4"-11- Notes: -BRP Type: A -VE ER W H 18-20258 Poles Page 2 of 4 POLE DATA 4" Straight Square Steel CATALOG NUMBER POLE SIZE MAXIMUM LUMINAIRE LOADING' ANCHOR BOLT DATA' HIGH WIND CONDITIONS NORMAL WIND CONDITIONS 130 MPH 120 MPH 110 MPH 100 MPH 90 MPH 110 MPH PREFIX HEIGHT (FT.) POLE SIZE (Inches) GAUGE EPA ITh Max Weight (lbs) EPA FTs Max Wkight (Rs) EPA FTs Max Weight (los) EPA FTs EPA FTs EPA FTs BOLT CIRCLE (Inches) BOLT SIZE (inches) MAX PROD. (trochee) SSS 10 4 I I i 9.9 248 12.0 300 14.5 363 18.9 7.3.9 30.6 8.0" 3/4 x 17 x 3 4.0" SSS 12 4 II 7.4 185 9.2 230 11.3 283 14.8 18.8 24.4 8.0" 3/4 x 17 x 3 4.0° 555 14 4 I I 5.5 138 7.0 175 8.8 220 11.7 15.1 19.9 8.0" 3/4 x 17 x 3 4.0" SSS 15 4 11 3.8 95 5.0 125 6.7 168 8.9 11.8 15.9 8.0" 3/4 x 17 x 3 4.0" SSS 18 4 I I 2.3 58 3.5 88 4.8 120 6.7 9.2 12.6 8.0" 3/4 x 17 x 3 4.0" SSS 20 4 1 I - 1.9 48 3.3 83 45 6.7 9.6 8.0" 3/4 x 17 x 3 4.0" SSS 20 4 7 4.3 108 5.6 140 7.4 185 8.8 11.8 16.0 8.0" 3/4 x 17 x 3 4.0" SSS 25 4 1 I - - - - - - 1.0 2.6 4.8 8.0" 3/4 x 17 x 3 4.0" SSS 25 4 7 1.6 40 2.6 65 3.8 95 5.4 7.7 10.8 8.0" 3/4 x 17 x 3 4.0" SSS 30 4 7 - - - 11 50 2.6 4.4 6.7 Sr 3/4 x 17 x 3 4.0" 1. Warning: Additional wind loading, In terms of EPA from banners, cements, floodlights and other accessories amdad to the pole, must be added to the haniuire(s) EPA before selecting the pole with the appropriate wind load capability. 2. Factory supplied template must be used when setting anchor bolo. Philips Gardco will not honor any daim for incorrect anchorage placement resulting frau failure to use factory supplied templates. DIMENSIONS Cut hole in template 1/16" larger than diam- eter of anchor bons used. S5S4 Pole 8" Bolt Circle (20.32cm) dult opening 3.64" ( 9.245cm) NOTE: Factory supplied template must be used when setting anchor bolts. Philips Gardco will not honor any claim for incorrect anchorage placement from failure to use factory supplied templates. 1011 Clovis Barker Road, San Marcos,TX 70040 (500) 227-07511 (512) 753-1000 FAX:(512) 753-71155 dtellghting.com 0 2011 Koninklijke Philips Electronics N.V. All Rights Reserved. Philips Gardco reserves the right to change materials or modify the design of its product without no:26cadon as part of the company's continuing product improvement program. 79415-17/0611 Top Nuts (4) Lodi Washer' (see Noce Below) Fiat VVashert (8) Grout as required after leveling pole" Concrete footing to suit soil conditions *Anchor Bolt Lock Washers are not normally required and are not included in standard anchor bolt sets.They are available upon request at additional con. ee Grouting should indude a drainage dot or tube (by others) to permit water to drain from the baso of the pole. Failure to provide drainage may weaken the pole bane structure aver time and may result In pole base failure, for which Philips Gardco is not responsible. PHILIPS GARDCO Submitted On: Jun 19, 2018 2/4 Index Page Submitted by ERW LIGHTING + CON Job e: Lantem Landing Lighting Designer: LIGHTWIRE - SEATTLE (SEATTLE) c W LIGHTING + CONTRC Poles Page 3 of 4 SPECIFICATIONS 4" Straight Square Steel POLE SHAFT: The pole shaft is fabricated from a single -piece of I I ga (.1196") or 7 p (.17931 commercial carbon steel. The formed steel plate is longitudinally welded providing minimum yield strength of 46 KSI. ANCHOR BASE The pole anchor base is fabricated from A-36 structural quality carbon steel with a minimum yield strength of 36 KSI. The base plate telescopes the pole shaft and is circumferentially welded on both top and bottom. ANCHOR BOLTS: Anchor bolts are fabricated from a commercial quality hot rolled carbon steel bar that meets or exceeds a minimum guaranteed yield strength of 50,000 psi. Bolts have an "L" bend on one end and threaded on the opposite end. Anchor bolts are galvanized a minimum of 12" on the threaded end. Four (4) properly sized bolts, each furnished with two (2) regular hex nuts and two (2) flat washers, are provided per pole, unless otherwise specified. GENERAL POLE INFORMATION BASE COVER: A two-piece base cover completely conceals the entire base plate and anchorage. HAND HOLE: The reinforced hand hole has a nominal rectangular 2" X 4" inside opening in the pole shaft. Included is a cover plate with attachment screws. The hand hole is located 18" above the base and 180° clockwise with respect to the luminaire arm when viewed from the top of the pole for one arm. For two arms the hand hole is located direcdy under one arm. POLE TOP CAP: Each pole assembly is provided with a removable pole top cap. FINISH: Poles are available with a bronze, natural, white or black electrostatically applied, thermally cured TGIC polyester powdercoat finish. STOCK POLES: Poles provided from stock under the Quick Ship program are drilled for four (4) luminaires at 90° with three (3) hole seas plugged. DESIGN: The poles as charted are designed to withstand dead loads and predicted dynamic loads developed by variable wind speeds with an additional 30% gust factor under the following conditions: The charted weights include luminaire(s) and/or mounting bracket(:). The wind velocities are based on 10 mph increments from 80 mph through 100 mph. Poles to be located in areas of known abnormal conditions may require special consideration. For example: coastal areas, airports and areas of special winds. Poles are designed for ground mounted applications. Poles mounted on structures (such as buildings and bridges) may also necessitate special consideration requiring Philips Gardco's recommendation. Height correction factors and drag coefficients are applied to the entlre structure. An appropriate safety factor is maintained -based on the minimum yield strength of the material incorporated In the pole. WARNING: This design information is intended as a general guideline only. The customer is solely responsible for proper selection of pole, luminaire, accessory and foundation under the given site conditions and intended usage. The addition of any items to the pole, in addition to the luminaire, will dramatically impact the EPA Toad on that pole. It is strongly recommended that a qualified professional be consulted to analyze the loads given the users specific needs to ensure proper selection of the pole, luminaire, accessories, and foundation. Philips Gardco assumes no responsibility for such proper analysis or product selections. Failure to insure proper site analysts, pole selection, Toads and installation can result in pole failure, leading to serious injury or property damage. GENERAL INFORMATION: Mounting height is the vertical distance from the base of the lighting pole to the center of the luminaire arm at the point of luminaire arrarhmentTwin arms as charted are oriented at 180° with respect to each ocher. For applications of two (2) arms at 90° or other multiple arm applications, consult the factory. WARRANTY: Philips Gardco poles feature a I year limited warranty. See Warranty Information on www.sitelighting.com for complete details and exclusions. 1611 Clovis RarIo r Road, San Marcos,TX 711666 (100) 227-07511 (512) 753-1000 FAX: (512) 753-7155 sitelighting.com C 2011 Koninklijke Philips Electronics N.V. All Rights Reserved Philips Gardco reserves the right co change materials or modify the design of its product without notifiotbn as part of the company's continuing product improvement program. 79415-17/0611 PHILIPS GARDCO Submitted On: Jun 19, 2018 3/4 Index Page Submitted by ERW LIGHTING ER W LIGHTING + CONTRC Job e: Lantern Landing Lighting Designer: LIGHTWIRE - SEATTLE {SEATTLE) Catalog Numb SSS4-20-4"-11-. -BAP Notes: Type: A -VE ERWH18-20258 Poles Page 4 of 4 ORIENTATION INFORMATION 4" Straight Square Steel FACTORY INSTALLED OPTIONS AND ACCESSORIES 180° ------------- 900 0° Orientation is measured clockwise from the Hand Hole Center. For Factory Installed Options and Accessories, Specify Orientation from Hand Hole and Height Above Pole Base Where Required. STANDARD ARM MOUNT LUMINAIRE ORIENTATION • D I Drilled for Single Luminaire I/O DI HAND HOLE • D4 Drilled for 4 Luminaires at 90° 180° D2 Drilled for 2 Luminaires at 180° 111 Luminaire location 270° 90' 0° D2Q90 Drilled for 2 Luminaires at 90° 1130° Height Above Pole Base D3 Drilled for 3 Luminaires © 90° 270° 90° 1611 Clovis Barker Road, San Marcos,TX 79446 (too) 227.0755 (512) 753-1000 FAX: (512) 753-7555 eiteligltting.com © 2011 Koninldijke Philips Electronics N.V. All Rights Reserved. Philips Gardco reserves the right to change materials or modify the design of its product without notification u pan of the company's continuing product improvement program. 79415-17/0611 270° 0° 270° PHILIPS GARDCO Submitted On: Jun 19, 2018 4/4 Index Page GED . ,...,........_. CED KENT Lindsey Holstine Co tor: JNictric Project: Lantem Landing Crilog Number: X 4C520C2BK Type. B ecirand® WIREMOLD® Outdoor Ground Box Outdoor Ground Box, part of the Outdoor Power offering from Legrand Ground Breaking Innovation As the popularity of outdoor activities grows, so does the demand for connected outdoor spaces that include power, communications and AN. The Outdoor Ground Box from Legrand is the first product designed with power and safety in mind. It's the first in -ground product on the market that will deliver permanent power and uses a UL50E Type 6P rated wiring enclosure and has been tested and evaluated by Underwriters Laboratories, Inc. for safe operation year round. The Outdoor Ground Box is designed to handle the requirements of the outdoor space white blending into the landscape. Ifs perfect for spaces such as: outdoor retail shopping centers, corporate campuses, amusement parks, sports fields, hospitality, or any outdoor space power is required. Features & Benefits • Air Pocket Design - This innovative design traps and maintains an air pocket protecting the devices, plugs and connections from water, snow, and ice. Allow for safer operation year round. • Outdoor -Rated Construction - UV and chemical -resistant F1 rated nonmetallic materials, allows the box to hold up for years to come. • Three Durable, Premium Finishes - Outdoor -rated finishes to complement your space design. Choose from black, brown, or gray. • Holds up to 5000 lbs - Has an ANSI/SCTE 77 Tier 5 rating and can hold up to 5,000 lbs of load allowing for the occasional tractor or non -deliberate vehicular traffic. • Anti -Float Clips - Prevents the cover from floating up when flooded. This preserves the air pocket and ensures safe operation. • Smart egress door - Egress door auto adjusts to the size of cable, as well as locking in the closed position when not in use. Prevents cable damage and maintains a safer user experience. • Secure - Includes tamper-resistant tock to prevent unauthorized access. • Service feed flexibility - Each box comes with two (2) locations that will accept up to 1 1/4" trade size nonmetallic conduit, allowing for services to feed the box as well as to daisy chain to other boxes. • Modular design - Boxes are designed to interlock allowing endless number of boxes in the same location. Provides service separation, everything in one location, and easier installation. • Flush to the finished ground - The buried box can be made flush with any surface, grass, walkways (brick, pavers, concrete, etc). Reduces trip hazards and allows it to blend in with its surroundings. • ADA compliant - Meets all specifications for ADA guidelines. • cULus listed to UL50E Type 6P and IP68 requirements while in use - Tested and listed by Underwriters Laboratories, Inc. to UL2996 and ULC/ORD-C2996:2017 for use in the ground in all weather conditions. Vertical Markets • Commercial • Hospitality • Education • Parks • Entertainment • Healthcare • Retail • Transit Compliance c LOcULus Listed, File Number E486738, Guide QCNUQCNL7. us Outdoor Ground Boxes (Power Applications) are UL Listed to meet UL50E Type 6P and IP68 requirements. Outdoor Ground Boxes (Low Voltage Applications) are UL Listed to meet UL50E Type 4X and IP65 requirements. ED1782R3 — Updated November 2017 — For latest specs visit www.legrand.us/wir old EEC . , CED KENT Corertor: Project: log Number: Type Lindsey Hoistine JNAftiktric Lantern Landing X = 4C520C2BK B IIGNIMP-tatmca egran Outdoor Ground Box Installation Considerations Determine location to install the Ground Box: • The location must be in a well drained area, away from inlets and outfalls. • Do not install Box at low points or in areas prone to accumulate standing water. • Do not install Box in locations where it will be subject to deliberate vehicular traffic. - Box is rated for occasional non -deliberate vehicular traffic with a maximum 5,000 lb (22.2 kN) design load (ANSVSCTE 77 Tier 5). • Box should only be installed in locations where the grade is within 1% of level. • Box should be installed in sidewalks only where the grade is less than 2% in all directions. • Box installation in locations where the seasonally high water table is Tess than 3 feet (600mm) below finished grade is not recommended. • Consultation of a licensed professional engineer knowledgeable of local soils is recommended to determine if unsuitable or poor soils may be encountered at the intended Box location. • Do not install Box on unsuitable soils. - Unsuitable soils are those with unsatisfactory drainage characteristics and high volume change potential. Unsuitable soils are defined herein as USCS soil groups OL, OH, and PT (organic silts, organic clays, and peat). • Installation of Box on poor soils is not recommended without additional drainage improvements. A method for improving drainage and minimizing the potential for heave in frost -susceptible and other poor soils is presented in the product installation instructions. - Poor soils are those with poor drainage characteristics. - For warm and cold climates, poor soils are defined herein as USCS soil groups ML, MH, CL, and CH (inorganic silts and inorganic clays). Additionally, for cold climates poor soils include USCS soil groups GC and SC (clayey gravels and clayey sands). - Poor soils are not a concem for un -irrigated locations where the average annual precipitation is less than 30 inches (762mm). • Do not install Box in permafrost areas. • Box should not be installed in locations where bedrock is less than 3 feet (600mm) below finished grade. Environmental Code Ratings Type 6P Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts to provide a degree of protection against ingress of solid foreign objects (falling dirt); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow, hose directed water, and the entry of water during prolonged submersion at a limited depth); that provides an increased level of protection against corrosion; and that will be undamaged by the external formation of ice on the enclosure. Type 4X Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection against ingress of solid foreign objects (falling dirt and windblown dust); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow, splashing water, and hose -directed water); that provides an increased level of protection against corrosion; and that will be undamaged by the external formation of ice on the enclosure. The IP Code is an International Protection Marking per IEC standard 60529. IP 68 Enclosure is dust tight. No ingress of dust; complete protection against contact. Enclosure is protected in immersion beyond 1 meter. The equipment is suitable for continuous immersion in water under conditions which shall be specified by the manufacturer. Normally, this will mean that the equipment is hermetically sealed. However, with certain types of equipment, it can mean that water can enter but only in such a manner that it produces no harmful effects. IP 65 Enclosure is dust tight. No ingress of dust; complete protection against contact. Enclosure is protected from water jets. Water projected by a nozzle (6.3mm) against enclosure from any direction shall have no harmful effects. Glossary of Terms: USCS Unified Soil Classification System OL Organic silts and organic silty clays of low plasticity OH Organic clays of medium to high plasticity, organic silts PT Peat and other highly organic silts ML Inorganic silts and very fine sands, rock flour, clayey silts or fine sands with slight plasticity MH Inorganic sifts, micaceous or diatomaceous fine sandy or silty soils, elastic silts CL Inorganic clays of low to medium plasticity, gravely clays, sandy clays, silty clays, lean clays CH Inorganic clays of high plasticity, fat clays GC Clayey gravels, gravel -sand -clay mixtures SC Clayey sands, sand -clay mixtures ED1782R3 — Updated November 2017 — For latest specs visit www.legrand.us/wiremold 2 cep CED KENT Corr tor: Project: i log Number: Type. ,,•,,;_.., Lindsey Noistine AIMNimectric Lantern Landing X = . 4C520C2BK B egran Outdoor Ground Box XMii11116sw XB814C520Bk XB814C520GY Components Included: • Cover Flange • Cover Body • Textured Surface Plate • Egress Door • Handle • SOOW Cord • NEMA 6P Rated Wiring Enclosure • 2 20A Duplex Weather Resistant Receptacles • Tamper -Resistant Key & Lock NOTE: Lock Nut Tool IXBLNTI sold separately. Exterior Box Cover Assembly 5-20R - Exterior box cover assembly prewired with (2) 20A weather resistant duplex receptacles. Both duplex receptacles are wired together on a single circuit. Available in brown (XB814C520BNI, black (XB814C520BKI, or gray (XB814C520GYI. When used in conjunction with the ground box body (XB8141 the entire unit has a UL50E Type 6P & IP68 rating in outdoor locations. CAUTION: All ground box electrical circuits must be protected by a Ground Fault Circuit Interrupter upstream from the ground box. NOTE: Cover must be closed while in use. Use only molded plug and cord assemblies that are rated for outdoor use. NOTE: Maximum length of plug allowed at end of cord is 3" (76mm). TOP 11 1/8" (283mm) 0 73/8' (187mm) 1 7/8" (48mm) FRONT INSIDE VIEW 55/8" (143mm) Receptacle, NEMA 5-20R BACK 3/4' (19.1mm) —1 45/8" (117mm) ED1782R3 — Updated November 2017 — For latest specs visit www.legrand.us/wiremold 4 LURA LINE LIGHTING Project: Fixture Type: Area/Bollard LBOSFG3 H: 41.38 W: 7 IL Description This is a square-shaped bollard with a flat -top design with Type 111 refractor. It is very popular in public parks and walkways because it is both affordable and durable. The extruded aluminum housing with flush -mounting base and vandal -resistant screws, black powdercoat finish over chromate conversion coating, internal ballast tray, and 50,000 estimated life makes this fixture very easy to maintain. The LED tight source delivers up to 1,382. Lumens while using just 17 watts. Standard with electronic 120/277 dimmable driver. CSA listed for wet locations. Specifications Housing Extruded aluminum with die -east mounting pad Diffuser/Optics Clear Polycarbonate Light Source Max Watts Electrical Mounting Certification sig c us LTE 14.5 LTE - includes 50,000 Hr. LED tight engine with 120-277V constant current driver. Mounting kit with 8" anchor bolts included Manufactured in accordance with U.L. standard 1598 CSA Listed for Wet Locations AMERICA WET 10 SS Wr LOCATIONS Dimmable BARRY J Ordering Guide: Choose from each category, using designated code to specify. LBOSFG3 MODEL Diffuser/Optics I _1 i______ DIFFUSER LIGHT SOURCE Light Source Clear Polycarbonate Lens LIS LTE SOK - 14.5W/50K 2089 lumen LED Specifications subject to change without notice. 800-940-6588 Saes ct,liuraline.sa m www, I!3it'i<.'_ com FINISH EXTRAS Finish Standard BT - Black (textured) ZT - Bronze (textured) Lightin Extras (Order Separately) (D) FUSE DOUBLE FUSED (S) FUSE SINGLE FUSED BBI. 90 minutes Battery Backup - For LED only (100- 277V/S0-60Hz Input Voltage) SSP 10KV 120-277V Suppiemenral Surge Pr. tech -n Way IGEEp ..._.,_ . _ . _. CED KENT Lindsey Holstine CoMctor: - JN 1 ctric Project: Lantern Landing Clog Number: btV 231411U Typew gam srrTu:a SLV 4.72" x 4.72" 4.72" x 4.72' 15.75" 27.6" ARROCK GRANITE 70 SQUARE outdoor path, 4000K, ETL-wet, square, E26, salt & pepper, L/W/ 4.7274.72727.5" Item number 231411U Family ARROCK GRANITE ARROCK GRANITE 70 SQUAR', outdoor path, Name 4000K, ETL-wet, square, E26 salt & pepper, UW/H: 4.72"/4.72"/27.5" The ARROCK GRANIT series floor lamps, made of the natural product gr.nite, are available in two heights. The speci material selection makes each luminaire unique. ith their protection class IP44, they Description are suitable for .utdoor use. Optionally a ground spike as well as a •nnection box for the safe, electrical connection ' the rectangular lighting shaft is available. The two - ailable versions are connected to 120 power - pply. Light Source Lampholde / Socket E26 ventional Leng 4.72 in W':th 4.72 in Height 27.6 in Voltage 120 Volts Material Granite/Stainless Steel Color Salt & Pepper Installation Floor/Surface Dimming No ETL Listed Yes UL Listed No ETL No ETL Listed Dry ETL Listed No SLV Light;ng North America Inc. • 5022 Joanne Kearney Blvd, Tampa, Florida 33619 • T 813-349-1900 F 813-349-1907 info@slvlighting.com slvlighting.com Technical Details are subject to change. SLV Damp No ETL Listed Wet Yes SLV Lighting North America Inc. - 5022 Joanne Kearney Blvd, Tampa, Florida 33619 T 813-349-1900 F 813-349-1907 info@slvlighting,com slvlighting.com Technical Details are subject to change. CED KENT CoreVtor: Project: C og Number: Type sonatuan=0 Lindsey Holstine JNMVitectric Lantern Landing geV 231411 U C SLV Damp No ETL Listed Wet Yes SLV Lighting North America Inc. - 5022 Joanne Kearney Blvd, Tampa, Florida 33619 T 813-349-1900 F 813-349-1907 info@slvlighting,com slvlighting.com Technical Details are subject to change. ..........: (ND ... CED KENT Cor 49tor: Project: log Number: Type Lindsey Hoistine JN ctric Lantern Landing 231411 U C ,�: ;a SLV items of this series 231410U ARROCK GRANITE 40, outdoor path, rectangular, ETL- wet, E26, salt & pepper, 0/H: 4.72"/15.8" 231420U ARROCK GRANITE, outdoor path, 4000K, ETL-wet, square, GU10, salt & pepper, L/W/H: 4.72"/4.72"/27.5" 231430U ARROCK GRANITE ROUND 40, outdoor path, ETL-wet, rectangular, E26, salt & pepper, 0/H: 4.7"/15.7" 231431 U ARROCK GRANITE 70 ROUND, outdoor path, 4000K, ETL-wet, rectangular, salt & pepper, 0/H: 4.7727.5" 711373U ARROCK GRANITE 70 LED ROUND, outdoor path, 3000K, ETL-wet, round, salt & pepper, 0/H: 4.7"/27.5" 711393U ARROCK GRANITE 70 LED SQUARE, outdoor path, 3000K, ETL-wet, square, salt & pepper, L/W/H: 4.72"/4.72"/27.5" 7113740 ARROCK GRANITE 70 LED ROUND, outdoor path, 4000K, ETL-wet, round, salt & pepper, 0/H: 4.7"/27.5" 711394U ARROCK GRANITE 70 LED SQUARE, outdoor path, 4000K, ETL-wet, square, salt & pepper, L/W/H: 4.7274.72"/27.5" The ARROCK GRANITE series floor lamps, made of the natural product granite, are available in two heights. The special material selection makes each luminaire unique. With their protection class IP44, they are suitable for outdoor use. Optionally a ground spike as well as a connection box for the safe, electrical connection in the rectangular lighting shaft is available. The two available versions are connected to 120 power supply. Notizen SLV Lighting North America Inc. 5022 Joanne Kearney Blvd, Tampa, Florida 33619 • T 813-349-1900 • F 813-349-1907 • info@slvlighting.com slvlighting.com Technical Details are subject to change. Submitted by ERW LIGHTING + CON ER W LIGHTING + CONTRC Job R hie: Lantern Landing Lighting Designer: LIGHTWIRE - SEATTLE (SEATTLE) Catalog Num bp -15 Notes: Type: D ERWH18-20258 TRICK 360° BLADE EFFECT SPECIFICATION SHEET Project name: Type: PAGE: 1 OF 3 Surface mounted luminaire that emits a light blade without any unwanted dispersion. Design by Dean Skira Luminaire characteristics: Input load: 6W Lumens: 1051m Luminaire efficacy: 17Im/W Source: LED module, (LM -80 tested) 3000K 80CRI Lumen maintenance: >80% of initial lumens at 50 000 hours (L80),(LM-79 tested) Optics: 360° blade effect Mounting: Wall or ceiling mounted, installs on standard 4' junction box. Floor mounting in dry location only (interior) Material: Body: Die-cast aluminum Diffuser. PMMA Iens Hardware: Stainless steel screws Electrical: Universal high efficiency electronic power supply, rated at 50 000 hours, 120-277V or see remote power supply options on page 3. Finish: White RAL9016 or Gray RAL9007 painted finish with a high level of weather and UV resistance. The semi -gloss finish coating is electrostatically applied, durable acrylic enamel baked at high temperatures for superior color retentive finish. Weight: 1.1Ib (0.5kg) Contact temperature: Less than 50°C (122°F) Warranty: 5 year limited warranty Certification: cULus listed for wet location Ratings: IP66, 1107 DUE TO CONTINUOUS IMPROVEMENTS, THE INFORMATION HEREIN MAY BE CHANGED WITHOUT NOTICE. FRONT VIEW 5W (147mm) 1_ — _ SIOE VIEW LAST UPDATE: JULY 11, 2017 MD -R8 NORTH AMERICA CC)US 9320 Bout. St-lairanl, sub 100, Mmh6al (Quebec) Canada H2N 1N7 P. 514.523.1339 F.: 5145256107 www.iguaini-co.Jus Submitted On: Jun 19, 2018 1/3 Index Page Submitted by ERW LIGHTING + CON ERW LIGHTING + CONTRC TRICK 360° BLADE EFFECT Job NdFne: Lantern Landing Lighting Designer: LIGHTWIRE - SEATTLE (SEATTLE) SPECIFICATION SHEET Project name: Type: PAGE: 2 OF 3 TECHNICAL DMA visit iguuini.com/us for complete photometric data LOAD CCT CRI OPTIC (W) (K) LUMENS EFFICACY MAX CANDELA (Im) (Im / w) (cd) MODEL 6W ; 3000K • -o'H ■ -str=H 80 360' blade effect 105 17 335 I-BU27 Distance (h) Blade width Illuminance 3.2' 3.5' 45 fc 6.5' T 12 fc 9.B 10.6' 5.5 fc 19.6' 23.6' 1.5 fc DUE TO CONTINUOUS IMPROVEMENTS, THE INFORMATION HEREIN MAY BE CHANGED WITHOUT NOTICE. LAST UPDATE: JULY 11, 2017 MD - R8 C NORTH AMERICA VS 9320 Bdi Si -Laren( euro 100, Mortdd (orbbec) Canada H2N IN7 P.: 514.523.1339 F.: 51,4525.8107 www,guaini.conaus Submitted On: Jun 19, 2018 2/3 Index Page Submitted by ERW LIGHTING + CON Catalog Num I.BU27.SP10041S?15 Notes: Type: D ERWH18-20258 i-- cR w LIGHTING + CONTRC Job • . me: Lantem Landing LightingDesigner: LIGHTWIRE - SEATTLE (SEATTLE) TRICK SPECIFICATION SHEET PAGE: 3 OF 3 360° BLADE EFFECT Project name: Type: ORDERING INFO - - MODEL VOJAGE FINISH MODEL 0 I.BU27 VOLTAGE 0 UNV - 120-277V 0 REM - Remote FINISH 001 - White 0 15 - Gray REMOTE POWER SUPPLY OPTION REMOTE POWER SUPPLY OPTION (TO BE ORDERED SEPARATELY) Requirement for one (1) fixture: 5.7W, 350mA (for remote fixture only) 0 4549-0350-019-UNV-ED10 0 4549-0350-018-UNV-TE REMOTE POWER SUPPLY OPTION (TO BE ORDERED SEPARATELY) Watts Min -Max QTY Voltage Rated Dimming protocol Box dimensions Max distance xi full load (18AWG) Code 19 1-2 120-277V Outdoor 0-10V ELDOLED ECOdrive 14" X 4%" X 3" (355 X 12(3 X 76mm) 72ft (22m) 4 -0350-019-UNV-ED10 18 1-2 120V Outdoor Trailing edge (ELV) 14" X 4%" X 3" (355 X 120 X 76mm) 72ft (22m) 4549-0350-018-UNV-TE WIRING DIAGRAMS 'Multiple luminaires must be connected in series (home run or fixture chain) POWER + - SLY ' 1 + i _ _ Y + 1 t -t.. T 1 - DUE TO CONTINUOUS IMPROVEMENTS, THE INFORMATION HEREIN MAY BE CHANGED WITHOUT NOTICE. LAST UPDATE: JULY 11, 2017 MD - RE • • 9320 Boa SI-I_aurent, sults 103, Weed (Quebec) Canada H2N 1N7 C P.:514.523.1339 F.: 514.525.6107 NY.W.igUZZirR.COROR NORTH AMERICA Submitted On: Jun 19, 2018 3/3 Index Page WLIGHTING + CONTRC Job e: Lantern Landing Lighting Designer: LIGHTWIRE - SEATTLE (SEATTLE) 0 LIGHTING SINCE 198E SPECIFICATIONS - A01 - BL neonVIEW Diffused, Flexible, Linear LED Lighting Side Emitting, 24VDC, Constant Voltage SL Series Certification Printed Odd 0 ®ell P67 0-10V MLV DMX LOW urn Lighting w 0•••• RGB 3000K 4000K 5700K Red Green Blue Amber Lamp Load Beam Angle Average Life Lumens Efficacy Electrical LED, SMD 5050, 33 Diodes/FT 3.66W/FT (White) 1600 50,000 Hours 146 Im/FT (White) 401m/W (White) Control Input voltage Max Input Current Connections Operating Temprature Circuit Mechanical 0-10V, MLV. DMX 24VDC 4.12A (White) IBAWG, Copper Conductors -4°F to 104°F (-20°C to 40°C) Class 2 Housing Construction Cutting Increments Maximum Run Length Medial Bend Radius Environmental Mounting Accessories Injection Moulded White PVC 2.19' (5.56cm) 27'(8.3M) 4 - 3/4' (120mm ) 1P67 Seamless Injection Clip. Track BL neonVIEW SI TK BL neonVIEW SL JC Termination Kit, Factory Installed Jumper Cable. Factory Installed IPROJECT ICLIENT Sold State lighting is sensitive to power fluctuations Surge protection is highly recommended for oil orb lighting products and snood tie on a designated circuit to 1.005 M surge protection moy void your warranty Ill LIGHTINSI.ILLUMINATE EVERYTHING In - 8838 heather St Vancouver. BC. Canada. V61' 3S8 P:I -604-874-4405 F. 1-604-321-0445 E. inlo(av7Gdigttirg.com Copyright 2017 81. INNOVATIVE LIGHTING, All Rights Reserved otect against premature failure ITYPE Fat rrae. Mmmofia 0 pieose orw, ood the SL LIGHTING c emgo Iblllghting.com o. Submitted On: Jun 19, 2018 1/2 Index Page Submitted by ERW LIGHTING + CON Job e: Lantern Landing Lighting Designer. LIGHTWIRE - SEATTLE (SEATTLE) =RW LIGHTING+ CONTRC Catalog Num NEONVIEW Sb B 24V M1 Notes: Type: E ERWH18-2025B 0 LIGHTING SINCE 1988 SPECIFICATIONS - A02 - BL neonVlEW SL Series Diffused, Flexible, Linear LED Lighting Side Emitting, 24VDC, Constant Voltage SLCP MOUNTING CLIPS INCLUDED Dimensions Performance IPrinted CCT/Color load LumensEfficacy Max, Run Length 3000K 3.66 W/FT 128 Im/FT 35 Im/W 27 ft 4000K 3.66 W/FT 146 Im/FT 40 Im/W 27 ft 57001: 3.66 W/FT137 Im/FT 37 Im/W 27 ft Red 2.20 W/FT 40 Im/FT 18 Im/W 45 ft Green 3.66 W/FT 91 Im/FT 25 Im/W 27 ft Blue 3.66 W/FT 15 Im/FT 4 Im/W 27 ft Amber 2.20 W/FT 40 Im/FT18 Im/W 45 ft RGB 3.66 W/FT 54 Im/FT 15 Im/W 16.4 ft Orderin+ Series BL neonVlEW SL CCT/Color 30 = 3000K 40 = 4000K 57 = 5700K RD = Red GN = Green BE = Blue AR = Amber M7 = n38 Ingress Protection Lead Orientation" 67 = IP67' SC = Side BC = Back • tead Criantotbn choke only available for IP67 s.arnl.a. Side Lead (IP67 Seamless) Back Lead (1P67 Seamless) IPROJECT Solid State L'gnring is sensitive to power fluctuations Surge de: Keenan is highly recommended for oil LEO WS tack of surge protection may void your worronty 0 ICLIENT I TYPE ono should bo on o designated circuit to protect against premature failure IBL LIGHTING. ILLUMINATE EVERYTHING 111 8836 Heather 5t, Vancouver,13C. Canada V6P 358 P: 1-604-874-4405 P. I-604-3260445 E: itfoplbiM1ghting.com Copyright 9 7017 BL INNOVATIVE 1!GHTING, Al Rights Reserver la more Tfrrrnatiart pease download the BL LIGHTING catalogue a o 1 bllighting.com Submitted On: Jun 19, 2018 2/2 Index Page Submitted by ERW LIGHTING + CONTr (Th LIGHTING + CONTRC Job e: Lantern Landing Lighting Designer: LIGHTWIRE - SEATTLE (SEATTLE) 0 LIGHTING SINCE 1986 SPECIFICATIONS - A01 - 1BL neonVIEW Diffused, Flexible, Linear LED Lighting Side Emitting, 24VDC, Constant Voltage i Certification IPrinted 046©©O©� IP67 0-I0V MLV DMX Low Lighting 0•••0 RGB 3000K 40004: 5700K Red Green Blue Amber Lamp Load Beam Anyle Average Life Lumens Efficacy Electrical LED, SMD 5050, 33 Diodes /F-1 3.66W/FT (White) 160° 50,000 Hours 146 Im/FT (White) 401m/W (White) Control Input Voltage Max Input Current Connections Operating Temprature Circuit Mechanical 0-10V, MLV. DMX 24VDC 4.12A (White) 18AWG, Copper Conductors -4°F to 104°F (-20°C to 40°C) Class 2 Housing Construction Cutting Increments Maximum Run Length Medial Bend Radius Environmental Mounting Accessories Injection Moulded White PVC 219' (5.56cm) 27 (8.3M ) 4 - 3/4' (120mm ) IP67 Seamless Injection Clip, Track B[ neonV*OW SL TK BL neonVIEW SL JC Terminodon Kit, Factory Installed Jumper Cable, Factory Installed IPROJECT sold State lighung IS Surge protection n hi tack of surge protea) ICLIENT QnSIIIve to rower fluctuatans hly recomrnendod for all LED Iigheng products and should o0 on a designated circuit to protect against premature 10 000 n may void your warranty 6l LHONTINO. ILLUMINATE EVERYTHING 111 • 6838 Heather St. Vancouvar.8C. Canada. V6P 358 P: 1-604-674-4405 F. 1-604-321 0445 E info(dblliyhting.com Copyright 0 2017 81 INNOVATIVE LIGHTING. 411 Rights Reserved. ITYPE Ifor mare IMarinotiort plesde download the 81 LIGHTING catalogue Ibllighting.com Submitted On: Jun 19, 2018 1/2 Index Page Submitted by ERW LIGHTING CO S (Th a -RV./ LIGHTING + CONTRC \s,_} Job e: Lantern Landing Lighting Designer: LIGHTWIRE - SEATTLE (SEATTLE) Catalog Num SLTKSMBC TQINATION KIT Notes: Type: E ERWH18-20258 0 LIGHTING meet 1888 SPECIFICATIONS - A02 - BL neonVIEW Diffused. Flexible, Linear LED Lighting Side Emitting, 24VDC, Constant Voltage Dimensions SL Series Performance IPrinted CCT/Color Load Lumens Efficacy Max, Run Length 3000K 3.66 W/FT 128 Im/FT 35 Im/W 27 ft 4000K 3.66 W/FT 146 Im/FT 40 Im/W 27 ft 5700K 3.66 W/FT 137 Im/FT 37 Irn/W 27 ft Red 2.20 W/FT 40 Im/FT 18 1m/W 45 ft Green 3.66 W/FT 91 Pm/FT 25 Im/W 27 ft Blue 3.66 W/FT 15 Im/FT 4 Im/W 27 ft Amber 2.20 W/FT 40 !al/FT 18 Im/W 45 ft RGB 3.66 w/FT 54 Im/FT 15 Im/W 16,4 ft Ordering Series CCT/Color BI neonVIEW SL 30 = 3000K 40 = 4000K 57 = 5700K RD = Red GN = Green BE = Blue AR = Amber MI = RGB Ingress Protection Lead Orientation' 67 = 1P678 SC = Side BC = Back • Lear] Orientation choice only ovollolol• for 007 %wok's, Side Lead (1P67 Seamless) Back Lead OW Seamless) 2 [1 IPROJECT CLIENT I TYPE Solid State lighting is sensitive to power fluctuations Surge protection is highly recommended for all LEO lighting products ono should be on a designated circuit io protect against premature failure of surge protection tray weld your warranty 81. LIGE4'TIt40.11LUTAINATE EVERYTHING 111 . 8838 Heather St, Vancouver. 8C. Canada. V6P 358 Pi 1.604-874-4405 F. 1-604 -321- 0445 L. info@bilighting.com Copyright 12 701701 INNOVATIVE LIGHTING, All Rights Reserved. ror ri-cre ink:cm:Port pease ee...ubooe 80 81 UGHT1NO cotes:gm 3r1t70, 1 bIlighting.com b Submitted On: Jun 19, 2018 2/2 Index Page Submitted by ERW LIGHTING (Th ER W LIGHTING + CONTRC CONT Job e: Lantern Landing Lighting Designer: LIGHTWIRE - SEATTLE (SEATTLE) 0 LIGHTING !INCE 1986 SPECIFICATIONS - AO - BL CBOX DMX Fully Assembled Control + Power Boxes Dual CirbUit,100W, 24VDC, CV, DMX512 Enabled FH100BCDL Certification Printed 4d Q cOus 1P66 DMX LISTED Electrical Input Voltage Input Frequency Max Input Current Output Voltage Load Connections Min Load Power Factor Operating Temperature Circuit Control Mechanical 120V - 277VAC 60 Hz (x2) 2A x2 24VDC, 4.17A, Constant Voltage x2 100W 18 AWG, Copper Conductors 20% - 25% 0.9 -30°C to 60°C Class 2 DMX512 Enclosure Construction Certificate Weight Environmental Assembly PVC High Temperature Flame -Proof Plastic UL2108, UL 1598/CSA 250.0, UL 8750, CSA 250.13 IP66, NEMA 1, 2, 3R, 4, 4X, 6, 6P, 12, 13 PVC Enclosure (x2) LED Driver (x2 DMX Decoder, 4CH Carbon Steel Back -Plate Surge Protector Strain Relief (Set) Electrical Connectors (Set) IPROJECT ICLIENT Sofd State Lghung is sensitive la power fluctuations Surge protection is nighty recommended for all LED lightmg products one should co on a designated circuit to protect against premature to.lure lack of surge protection may vote your warronty BL LIGHTING. ILLUMINATE EVERYTHING 111 - 8838 Heather St. Vancouver, BC. Canada V6P 358 P: 1-604-874-4405 E. I-604.321-0445 E. inlo@bllghting.com Copyright 0 2017 81. INNOVATIVE LIGHTING. All Rights Reserved. TYPE Inor rare information. please d0Nrllaad the BL LIGHTING coloio9l.4 Ibliighting.com Submitted On: Jun 19, 2018 1/2 Index Page Submitted by ERW LIGHTING + CON 2 vv LIGHTING +CONTRC Job e: Lantern Landing Lighting Designer: LIGHTWIRE - SEATTLE SEATTLE) Catalog Numb FH100BCDL 2P0 24VDC Notes: Type: E ERWH18 20258 CIO LIGHTING SINCE Mee SPECIFICATIONS - A02 - IBL CBOX DMX Fully Assembled Control + Power Boxes Dual Circuit, 100W, 24VDC, CV, DMX5I2 Enabled Dimensions FH100BCDL IPrinted 345 125.4 15 14 U.1 IPROJECT ICLIENT I TYPE Solid Stole tighting is. 50110100 10 power fluctuations Surge protectian is highly recommended for all laD lighting products and should he on a designated 1150011 10 protect ogainsf prernoture failure 1010 01 surge protection may void your warranty IL LIGHTING. 11.111MINATF EVERYTHING III 6839 Heather SL Vancouver, BC, Conackl. 5411 358 0: 1-604 .874-4405 1: 1-604-321-0445 0: infopellighting.corn Copyright C 2017 at INNOVATIVE LIGHTING. AN Rights Reserved Ila !TM e4ol-nom:41 pease download the 81. LIGHTING catalogue I blltghting.com Submitted On: Jun 19, 2018 2/2 Index Page Submitted by ERW LIGHTING + CON R»/ LIGHTING + CONTRC Job e: Lantern Landing Lighting Designer: LIGHTWIRE - SEATTLE (SEATTLE) OLIGHTING 1006 SPECIFICATIONS - A01 - 131. controlTASK DMX DMX5I2 Master Controller Programmable ma= 4 78% ETH Certification IPrinted oda A 0 (10) IP20 LOW DMX Electrical Input Voltage Operating Temprature Mechanical 6VDC, 0.6A 14°F to 113°F -I0°C to 45°C) Housing Construction Glass Touch Panel, Black Frame Mounting Single or Double Gang Wall Socket Weight 0.541b (247g) Environmental 1P20 Features • DMX 512 Protocol • Clock & Calendar Trigger • 2 Universes • Mac OSX and Windows • Intuitive Control Palette • Smart Phone App • LCD Screen Connections Mini -USB 2.0 RS232 Ethernet 8 Dry Contact Points 5V Output Relay IPROJECT ICLIENT I TYPE SoIVI State tghung is sensitive to power Suctuatons Surge protection O flighty recommended for all LED lighting products and shcutt be on designated circuit to promo ogoinst premature loilure 000 14 surge p14000000 19009 void your warronty Gt LIGHTING. RUMINATE EVERYTHING Irl ' 8838 Heather St Vancouver, BC, Conadd, V6P 3S8 9: 1-604-874- 4405 F. 1-604 321' 0445 iinIo@bIIightirrg.com Copyright Cs 201701 INNOVATIVE 1.101111Na 511 Rights Reserved, IFor more Initymarion, Ocoee arrerexId rhe 81 UOHTING catalogue 1 bllighting.com b Submitted On: Jun 19, 2018 1/2 Index Page Submitted by ERW LIGHTING + CON (Th ER N,V LIGHTING +CONTRC Job me: Lantern Landing Lighting Designer: LIGHTWIRE - SEATTLE (SATTLE) Catalog Num ETI -1 MASTER C ROLLER DMX512 PROGRAMMABLE AREA CONTROLLER Notes: Type: E ERWH18 2025a 0 LIGHTING susCE 1936 SPECIFICATIONS - IEIL controlTASK DMX DtvIX5!2 Master Controller Programmable Dimensions I ETH IPrinted 146.0 I5-11 \ <106.2 4 1...,...„,,..77 ---- IPROJECT ICLIENT Sotid State Lighting is sensitive to power fluctuations Surge protection is highly recommended for all 1.E0 lighting products ond should be on designated 00,011 10 protect ogoinsr pa0,a1ur0 (oiiure lack of surge protection may sold your warranty Ill LIGHTING. ll LUMINATE EVERYTHING 111 8838 Heather St. Vancouver. 8C, Canada. 460 358 P: l -604 -SN -4405 F. 1-604- 321- 0445 t.' inf0@blfighting.com Copyright 0 2017 Ell INNOVATIVE tIGNING. All Rights Reserved. ITYPE rBtrazte tnforstokin pexse dow-bod the LIGHTING catalogue IbIlighting.com Submitted On: Jun 19, 2018 2/2 Index Page Submitted by ERW LIGHTING + CONT ER LIGHTING + CONTRC Job N9The: Lantem Landing Lighting Designer: LIGHTWIRE - SEATTLE (SEATTLE) 0 LIGHTING SINCE 1988 SPECIFICATIONS - A01 - BL controlTASK DMX DMX 512 Amplifier / repeater AMP Certification 1 Printed /d L ©CM IP20 LOW DMX Electrical Input Voltage Max Input Output Connection Type Operating Temprature Mechanical 12-24VDC 0.5A DMX5I2 signal Screw Terminals 32°F to 122°F (0°C to 50°C) Housing Construction Weight Environmental Plastic, White 0.31b (138g) IP20 IPROJECT ICLIENT Sofia Slate tghung is sensitive to poste, fluctuations Surge protection is highly recommended for oil tE,D lighting products and should tie on o designated circuit to protect ogoins1 premature Ioilure Lack of surge protection may void your warranty UL UGHTINO. ILLUMINATE EVERYTHING 111 8838 Heather Sr. Vancouver, BC. Canada. V60 3S8 P: 1-604-874-44051. 1-604-321 0445 E. info(dlblligh5ng.com Copyright 9 2017 8i INNOVATIVE LIGHTING All Rights Reserved. TYPE rrcmore rkamlation. please eo nbotl rhe ILL LIGHTING caldagte Ibilighting.com Submitted On: Jun 19, 2018 1/2 Index Page Submitted by ERW LIGHTING + CON Job Name: =R W LIGHTING + CONTRC Lantern Landing {Lighting Designer: LIGHTWIRE - SEATTLE EAiTL ) Catalog Num DMX512 REPS ER Notes: Type: E ER W H 18.20258 0 LIGHTING SINCE 1988 SPECIFICATIONS - A02 - IBL controlTASK DMX DMX 512 Amplifier / repeater Dimensions AMP I Printed IPROJECT 1 CLIENT I TYPE Sold state ugrreng Is sensitive to power fluctuations Surge protection Is highly recommended lar all LED lighting products dna should ea on a designated circuit to protect against premature failure Lock of surge protection may void your warranty BL LIGHTING. ILLUMINATE EVERYTHING III - 9830 Hea!her 51. Vancouver. BC. Canada. V6P 358 P. 1504-074-4405 t. I-604-321-0445 E. in1414ailghting.com Copyrigr9 O 701; BL INNOVATIVE LIGHTING. AA Rights Reserved. 110 more i4onrotim. pleo$edonead the BL LIGHTING catalogue Iblllghting.com Submitted On: Jun 19, 2018 2/2 Index Page Submitted by ERW LIGHTING E W LIGHTING + CONTRC + CONT Job e: Lagntem Landing Lihtin g E)signer: LIGHTWIRE - SEATTLE 0 LIGHTING SINCE 1886 SPECIFICATIONS - A01 - BL controlTASK RESISTOR RESISTOR Features IPrinted Power Rating 1/6 W Resistance 120 ohm Tolerance ± 5% IPROJECT Solid state Lighting is sensitive to power fluctuonons Surge protection is highly recommended for 011 1ED light, Lack of surge protection may void your warranty pr ICLIENT I TYPE cls and should be on o designated circuit le protect ogoinst premature taYure Si LIOHTING. ILLUMINATE EVERYTHING 111 _ 88381bolher SI. Vancouver. BC. Canada. VBP 308 P: I-604-874,4405 P. 1-604-371-0445 E. inlo@bigntngcom Copyright 22 7017 B1 INNOVA NIVI IIGHIPIO. All Rights Reserved. IPor mare id0: rnotian, please downlocd 810 BL LIGHTING rrsra-�jw Ibllighting.com Submitted On: Jun 19, 2018 1/1 Index Page Submitted by ERW LIGHTING + COS (Th ERW � LIGHTING+CONTRC Job Rame: Lantern Landing Lighting Designer: LIGHTWIRE - SEATTLE (SEATTLE) Catalog Num • !MI DMXWR DMX t 'E 2 CONDUCTOR Notes: Type: E ERWH18-20258 411111 LIGHTING SINCE Ifee SPECIFICATIONS - A01 - BL controlTASK DMX Cable c:2/1 ,10 DMXWR Printed Certification C s us Features Flexible Rubber Shield Copper Conduct Inner Foil Shield PVC outer Jacket 22 AWG Wire Red : + Black : - Silver : OND IPROJECT CLIENT I TYPE Solid State tghang Is sensitive to power euctuarmns Surge protection is Righty recommended for all LED lighting products and should be on a designated circuit to protect against premature fe;lure Lack of surge protection may void your warranty Bt UN►HTIN6. ILLUMINATE EVERYTHING Ill 8838 l -Mother St. Vancouver. 6C. Cando. V6P 3S8 P: 1604-874-4405 F. 1-604- 321-0445 E. infa@bllighting.com Copyright 0 2017 8L INNOVATIVE LIGHT ING, All Rights Reserved. IPor mete 5do+rwuon, goose downksad the St LIGHTING catalogue bllighting.com Submitted On: Jun 19, 2018 1/1 Index Page (ND ., ..-.. ,��, CED KENT Lindsey Holstine Con tor: JNM ctric Project: Lantern Landing Cog Number: P77420/30K Type F L1t,1111\l; CYLINDER Specifications: NroleCt: Fixture Type: Locai:o, Cont. Ceiling mounted • \v Description: The P5774 Series are ideal for a wide variety of interior and exterior applications including residential and commercial. The Cylinders feature a 120V alternating current source and eliminates the need for a traditional LED driver. This modular approach results in an encap- sulated luminaire that unites performance, cost and safety benefits. Construction: Antique Bronze (-20) (powdercoat) Die cast and extruded aluminum construction metal shade Flicker -free dimming to 10% brightness with most ELV type dimmers (See Dimming Notes) Unit covers a standard 4" hexagonal recessed outlet box Mounting strap for outlet box included 6" of wire supplied Performance: Number of Modules Input Power Input Voltage Input Frequency Lumens/LPW CCT CRI Life EMI/RFI Min. Start Temp Mac. Operating Temp Warranty Labels Catalog number: 1 17W 120V 60Hz 757/46 (LM -79) per module 3000K 90 60,000 (L70/TM-21) FCC Title 47, Part 15, Class 8 -30 C 30 C 5 year warranty cCSAus Wet location listed Images: i PROGRESSIE9l P577+20/30K Dimensions: Diameter: 5" Height: 6-1/2" Sate' PS774 Finish Ankue Brom COO? Temp - CM 30K • 3000K Blank• 9 C*tl _i For more information visit our website: wwwprogresslighting.com Progress Lighting • 701 Millennium Boulevard • Greenville, SC 29607 GEED ,,._ _ ._ immoomaaaa CED KENT Lindsey Holstine Co ctor: JNfirjc Project: Lantern Landing Ceikitlog Number: )d577420/30K Type F CYLINDER Dimming Notes: Ceiling mounted Wet location listed P5774 is designed to be compatible with many Electronic Low Voltage (ELV-Reverse Phase) controls. The following is a partial list of known compatible dimmer controls: Electronic Low Voltage ELY Reverse Phase Controls Lutron Diva Series (Part Number DVELV-3ooP) Lutron Nova T Series (Part Number NTELV-3oo) Lutron Vierti Series (Part Number VTELV-6o0) Lutron (Part Number MAELV-600) Lutron (Pan Number SPELV-600) Leviton (Part Number AWRMG-EAW) Leviton (Part Number 6615-P) Digital type dimmers are not recommended. Dimming capabilities will vary depending on the dimmer control, load, and circuit installation. Always refer to dimmer manufacturer instructions or a controls specialist for specific requirements. Dimmer control brand names where identified above are trade names or registered trademarks of each respective company. PROGRESS P5774 -20/30K For more information visit our website: www.progresslighting.com Progress Lighting • 701 Millennium Boulevard • Greenville, SC 29607 D �.,... CED KENT Con tor: Project: Crlog Number: Type , Lindsey Holstine JNM Imiectric Lantern Landing 7420/30K F too 95 L1(,1111\(; CYLINDER Photometrics: ELECTRICAL DATA P5774 -20/30K Input Voltage 120V Input Frequency 60Hz Input Current 0.11A Input Power 17W Power Factor >0.90 THD <20% EMI Filtering FCC Title 47, Part 15, Class 9 Operating Temperature -30 C to 30 C Dimming Yes* Over -voltage, over -current, short-circuit protected *See Dimming Notes for more information P5774-2o/30K LED Light Engine: 3000K 90 CRI System Wattage: 16.3 Fixture delivered lumens: 764 Fixture Efficacy: 46.4 Spacing Criteria: 1.0 ISO ••' a•• IS. u• CANDELA DISTRIBUTION DEG CANDELA 0 431 5 428 15 412 25 329 35 233 45 158 55 94 65 57 75 29 85 9 90 0 O. ss• �• Test No. 16.00023 Tested at 25 C Ambient in accordance to IESNA LM -79-2008 ceiling mounted • Wet location listed PROGRESS!. D P5774-20f30K ZONAL LUMEN SUMMARY ZONE 0-30 0-40 0-60 0-90 90-18o o -18o LUMENS 306 452 659 757 0 757 %LUMINAIRE 40.5% 59.7% 87.1% too.o% o.o% 1 oo.0% COEFFICIENTS OF UTILIZATION Zonal Cavity Method a % Effective Ceding Cavity Reflectance 8o% 1 7o% 1 5o% 1 3o% 0.2 zo% Effective Floor Cavity Reflectance E I % Wall Reflectance °C 70 50 30 10 70 10 50 10 5o 10 1 110 106 103 99 108 98 too 95 96 92 3 94 85 78 72 92 72 81 70 78 69 5 81 7o 62 56 79 56 67 55 65 55 7 71 59 51 45 69 45 56 45 55 44 9 62 5o 43 38 61 38 49 37 48 37 P3774.,o/30K Test No. 16.00023 CEED ,- _- ___ .. CED KENT Lindsey Holstine Cotor: JN ectric Project: Lantem Landing got log Number: TOR4B Type G DESCRIPTION The patented Lumark Crosstour LED Wall Pack Series of luminaries provides an architectural style with super bright, energy efficient LEDs. The low -profile, rugged die-cast aluminum construction, universal back box, stainless steel hardware along with a sealed and gasketed optical compartment make the Crosstour impervious to contaminants. The Crosstour wall luminaire is ideal for wall/surface, inverted mount for facade/canopy illumination, post/bollard, site lighting, floodlight and low level pathway illumination including stairs. Typical applications include building entrances, multi -use facilities, apartment buildings, institutions, schools, stairways and loading docks test. SPECIFICATION FEATURES Construction Slim, low -profile LED design with rugged one-piece, die-cast aluminum hinged removable door and back box. Matching housing styles incorporate both a small and medium design. The smell housing is available in 12W, 18W and 26W. The medium housing is available in the 38W model. Patented secure lock hinge feature allows for safe and easy tool -less electrical connections with the supplied push -in connectors. Back box includes three half-inch, NPT threaded conduit entry points. The universal back box supports both the small and medium forms and mounts to standard 3-1/2" to 4" round and octagonal, 4" square, single gang and masonry junction boxes. Key hole gasket allows for adaptation to junction box or wall- External fin design extracts heat from the fixture surface. One- piece silicone gasket seals door and back box. Minimum 5" wide pole for site lighting application. Not recommended for car wash applications. DIMENSIONS Optical Silicone sealed optical LED chamber incorporates a custom engineered mirrored anodized reflector providing high -efficiency illumination. Optical assembly includes impact -resistant tempered glass and meets IESNA requirements for full cutoff compliance. Available in seven lumen packages; 5000K, 4000K and 3000K CCT. Electrical LED driver is mounted to the die-cast housing for optimal heat sinking. LED thermal management system incorporates both conduction and natural convection to transfer heat rapidly away from the LED source. 12W, 18W, 26W and 38W series operate in -40°C to 40"C [-40"F to 104°F[. High ambient 50°C models available. Crosstour luminaires maintain greater than 89% of initial light output after 72,000 hours of operation. Three half -Inch NPT threaded conduit entry points allow for thru-branch wiring. Back box is an authorized 12W, 1$W, 28W 6-3/4" 1171 mml 3$W 8" (203mm] fill 11 Jj:Jl!I .lis It It'tips mlm 111111111 12W, 151N, 26W 5-3/4" [146mm] 3FW 6-5/8" (168mm] Powering Business NbrlAwde 12W, 15W, 28W- 3-58" [92mm] 38W 4" 1102mm] Catalog q Project Lumark Comments Prepared by electrical wiring compartment. Integral LED electronic driver incorporates 2,urge protection. 120- 277V 50/60Hz or 347V 60Hz models. Finish Crosstour is protected with a Super durable TGIC carbon bronze or summit white polyester powder coat paint. Super durable TGIC powder coat paint finishes withstand extreme climate conditions while providing optimal color and gloss retention of the installed life. Warranty Five-year warranty. ESCUTCHEON PLATES 17 12" [445mm1 17- 2" (445mrnl L— 10" 1254mm1 10" (254mm] •www.designllghts.org XTOR CROSSTOUR LED IMME APPLICATIONS: WALL / SURFACE POST / BOLLARD LOW LEVEL FLOODUGHT INVERTED SITE LIGHTING CERTIFICATION DATA UL/cUL Wet Location Listed LM79 / LM80 Compliant ROHS Compliant ADA Compliant NOM Compliant Models IP68 Ingresaed Protection Rated Title 24 Compliant DealgnLights Consortium° Qualified* TECHNICAL DATA 40"C Maximum Ambient Temperature External Supply Wiring 90•C Minimum EPA Effective Projected Arae (Sq. R.1: XTOR18, XTOR28, xTOR38-034 XTOR48=0.45 SHIPPING DATA: Approximate Net Weight: 3.7 -5.25 lbs. [1.7 - 2.4 kgs] TD514013EN 2017-07-2512:21:69 MEG . ............: CED KENT Lindsey Holstine Cor ctor: JNOrrectric Project: Lantern Landing Clog Number: `` 68 j((TOR4B Type, G warnip.s. POWER AND LUMENS BY FIXTURE MODEL LEDlntormation XTOR1B XTOR1B-W XTOR1B-Y XTOR2B XTOR2B-W XTOR2B-Y XTOR3B XTOR3B-W XTOR3B-Y XTOR48 XTOR4B-W XTOR48-Y Delivered Lumens (Wall Mount) 1,418 1,396 1,327 2,135 2.103 1,997 2,751 2,710 2,575 4.269 4,205 3,995 Delivered Lumens (With Flood Accessory Kit)' 1,005 990 940 1,495 1,472 1,399 2,099 2.068 1,985 3,168 3,121 2,965 B.U.O. Rating' B1 -U0 -GO B1 -UO -GO 81 -U0 -GO 81 -UO -GO B1 -U0 -GO B1 -UO -GO B1 -UO -GO B1 -UO -GO B1 -U0 -GO B2 -U0 -GO B2 -U0 -GO 82 -U0 -GO CCT (Kelvin) 5,000 4.000 3,000 5,000 4,000 3,000 5,000 4,000 3,000 5,000 4,000 3,000 CRI (Color Rendering Index) 70 70 70 70 70 70 70 70 70 70 70 70 Power Consumption (Witte) 12W 12W 12W 18W 18W 18W 26W 26W 26W 38W 38W 38W NOTE& 1 Includes shield nd visor. 2 B.U.G. Rating does not apply to floodlighting. LUMEN MAINTENANCE Ambient Temperature TM -21 Lumen Melntenence (72,000 Hours) Theoretical L70 (Hours) XTOR1B Model 25•C > 90% 255,000 40•C > 89% 234,000 50°C > 88% 215,000 XTOR2B Model 25•C > 89% 240,000 40•C > 88% 212,000 50°C > 87% 196,000 XTOR3B Modal 25•C > 89% 240,000 40•C > 88% 212,000 50•C > 87% 196,000 XTOR48 Model 25°C > 89% 222,000 40•C > 87% 198,000 50°C > 87% 184,000 CURRENT DRAW Voltage Model Series XTOR'B XTOR2B XTOR3B XTOR4B 120V 0.103A 0.15A 0.22A 0.34A 208V 0.060A 0.09A 0.13A 0.17A 240V 0.053A 0.08A 0.11A 0.17A 277V 0.048A 0.07A 0.10A 0.15A 347V 0.039A 0.06A 0.082A 0.12A E:T•N Powering Business Worldwide 100 95 a a 0 85 F E °i 80 75 0 10 20 30 Hours (Thousands) Eaton 1121 Highway 74 South Peachtree City. GA 30269 P: 770486.4800 www.eatoncomA ighbng 40 Specifications and dimensions subject to cltange without notice. 50 60 70 80 90 100 50°C 40°C - 25•C - TD514013EN 2017-07-25 12:21:59 teD _ _...,. __ . CED KENT Co tor: Project: ^log Number: Type PCI=Photocontrol 120V ° Lindsey Holstine JNIerrectric Lantern Landing TOR4B G XTOR3B=Small Door, 26W ORDERING INFORMATION Sample Number: XTOR2B-W-WT-PC1 Series' LED Kelvin Color I Housing Color Options (Add as Suffix) Accessories (Order Separately) XTOR1B=Small Door, 12W ''Blank]--6,:gin V.4uo:, 181ank),Ca,I:P :. 3-:o- PCI=Photocontrol 120V ° WG/XTOR=Wire Guard' XTOR2B=Small Door, 18W ;Sidndn,,,^OUtiI iSta:r..:ar.b PC2,Photocontro1208-277V=s XTORFLD-KNC=Knuckle Floodlight Kit a XTOR3B=Small Door, 26W W=Neutral White, 4000K WT=Summit White 347V=347V' XTORFLD-TRN=Trunnion Floodlight Kit' XTOR48 .Medi on Dao,. 3fiV,, j Y=Warm White, 3000K BK=Black HA -0 C High Ambient' XTORFLD-KNC-WT=Knudde Floodlight Kit, Summit White. XTOR48-W-PC1=38W, 4000K, 120V PC, Carbon Bronze BZ=Bronze XTORFLD-TRN-WT=Trunnion Floodlight Kit, Summit White' AP=Grey EWP/XTOR=Eacutcheon Wall Plate, Carbon Bronze GM=Graphite Metallic EWP/XTOR-WT'Escutcheon Wall Plate, Summit White DP=Dark Platinum NOM& 1. DesignUghta Consortium' Qualified and classified for both DLC Standard and DLC Premium, refer to www.designlighta.org for details. 2. Photacontrols are factory installed. 3. Order PC2 for 347V modals. 4. Thru-branch wiring not available with HA option or with 347V. XTOR3B not available with HA and 347V or 120V combination. 5. Wire guard for wall/surface mount. Not for use with floodlight kit accessory. O. Floodlight kit accessory supplied with knudde (KNC) or trunnion (TRNI base, small and large top visors and small and large impact shields. STOCK ORDERING INFORMATION 12W Series 18W Series 26W Series 38W Sarins XTOR1B=12W, 5000K, Carbon Bronze XTOR2B=18W, 5000K, Carbon Bronze XTOR3B=26W, 5000K, Carbon Bronze XTOR4B=38W, 5000K, Carbon Bronze XTOR1B-WT=12W, 5000K, Summit White XTOR2B-W=18W, 4000K, Carbon Bronze XTOR3B-W=26W, 4000K, Carbon Bronze XTOR4B-W=38W, 4000K, Carbon Bronze XTOR1B-PC1=12W, 5000K, 120V PC, Carbon Bronze XTOR2B-WT=18W, 5000K, Summit White XTOR3B-WT=26W, 5000K, Summit White XTOR4B-WT=38W, 5000K, Summit White XTOR1B-W=12W, 4000K, Carbon Bronze XTOR2B-PC1=18W, 5000K, 120V PC, Carbon Bronze XTOR3B-PC1=28W, 5000K, 120V PC, Carbon Bronze XTOR4B-PC1=38W, 5000K, 120V PC, Carbon Bronze XTOR1B-W-PC1=12W, 4000K, 120V PC, Carbon Bronze XTOR2B-W-PC1=18W, 4000K, 120V PC, Carbon Bronze XTOR48-W-PC1=38W, 4000K, 120V PC, Carbon Bronze E:T•N Powering Business Worldwide Eaton 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.corn/lighting Specifications end dimensions subject to change without nonce. TD514013EN 2017-07-25 12:21:59 am .,.�,,...,.... CED KENT Lindsey Holstine CoMrictor: JN 4,tctric Project: Lantern Landing og Number: STRIPTA/032UNVD840/4 Type:. G IMMII=,�., www.sylvania.com SYLVANIA Luminaires Strip Product Features -- Snap fit for quick, and easy tool -less access -- End-to-end linkable for customized run lengths -- Offered in three wattagesAumen packages and two lengths -- Application: retail, manufacturing, warehouse, office, education and low bay applications Ordering Guide Item Number. STRIP 1A Product Nanta Catalog # Project Notes Date Prepared by Dimensions 4ft na•(1201.1mm) Type 21.1" (611.4mm) 1 1 Specifications Weight 2ft: 21 lbs (1.0 kg) 4ft: 4.0 lbs (1.8 kg) Construed= Sheet metal housing with powder coat paint finish and acrylic lens. The standard color is white. LED System: LED system with a lite rating of x50,000 hours at L70 ®25°C. Luminaire efficacy up to 127 LPW. Electrical: Offered in 16, 32, and 47 Watts, the luminaire is designed to operate through the 120-277 VAC voltage. The LED driver has a 4kV surge suppression and is a constant current device, meeting UL131 D and UL48 Class 1 with built-in over temperature protection. The power factor is x90% and THD is 520%. Dimming: The driver is 0-10V dimmable (down to 10%). Please reference the compatibility document (LEDLUM012). Color Characters: CHI>80; CCT of 3500K, 4000K or 5000K. Optics: Diffuse polycarbonate lens. Installation: Luminaire is surface or suspension mounted. Operating Temperature: -13°F to +104°F (-25°C to +40°C). Listings: cETLus listed to UL1598 standards and for damp locations. Warranty: Standard 5 -year luminaire warranty (LEDLUM001). Note: Specifications subject to change without notice. IES files available online. LEDLUM031 2-18 XX S / WH Dimensions Mountino CalariFinisli 74= 24 in Surface WH=White SYLVANIA 0 D .,. .. . . CED KENT Co ctor: Project: log Number: Type Lindsey Holstine JNfectric Lantem Landing STRI 032UNVD840/4 G Ordering Information Rem Ordering Power Input Color Temp Total Fixture Number Abbreviation (W) Voltage Dimming CRI (CCT) Size Lumens LPW* DLC** 70525 STRIP1A/016UNVD835/24S/WH 16 120.277V 0-10V >80 3500K 2ft 2000 124 Std 70526 STRIP111/016UNV0840/24S/WH 16 120-277V 0-10V >80 4000K 2ft 1900 119 Std 70527 STRIP1A/016UNVD850/24S/WH 16 120-277V 0-104 >80 5000K 2ft 2000 122 Std 74774 STRIP1A/032LJNVD835/48S/WH 32 120-277< 010V >SO_ 351101< 4ft 3900 121 Std I 70522 STRIP1A/047UNVD835/48S/WH 70523 STRIP1A/047UNVD840/48S/W1-1 70524 STRIP1A/047UNVD850/48S/WH "OW pa LAI79 repod "SeIotCSv,dwd. 47 120-277V 0-10V 47 120-277V 0-10V 47 120-277V 0-10V Stk. 'u) o0vvr. 411 4truu t 24 Sid >80 3500K 4ft 5900 123 Std >80 4000K 4ft 6200 126 Std >80 5000K 4ft 6000 124 Std LEDVANCE LLC 200 Ballardvale Street Wilmington, MA 01887 USA Phone 1-800-LIGHTBULB 1 -800-544-4828) www.sylvania.com atilt FDIAliir,5 trademarks. Aar ,trspective owners. L`,tradtrtrak,> UAW. in goner& litrfitrog. /sylvania isylvanta Zln? 1-WA,ICL L.LC- SYLVANIA 0 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL18-0804 PROJECT NAME: LANTERN LANDING SITE ADDRESS: 1233 ANDOVER PARK E X Original Plan Submittal Response to Correction Letter # DATE: 09/24/18 Revision # Revision # before Permit Issued after Permit Issued DEPARTMENTS: PC\7 Building Division Fire Prevention Public Works Planning Division r Structural Permit Coordinator E PRELIMINARY REVIEW: Not Applicable ri (no approval/review required) DATE: 09/25/18 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR Approved DUE DATE: 10/23/18 1-1 Approved with Conditions 111 Corrections Required E Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 JNM Electric Inc Page 1 of 2 Home i sp hol Contact Search L&I Safety & Health Claims & Insurance Cli) Washington State Department of Labor & Industries A-7 Index Help Mt L&I Workplace Rights Trades & Licensing JNM Electric Inc Owner or tradesperson Principals McCoy, Derek, PRESIDENT Baker, Warren, AGENT Doing business as JNM Electric Inc WA UBI No, 603 328 920 po box 7059 BONNEY LAKE, WA 98391 253-439-8892 PIERCE County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor License specialties GENERAL License no. JNMELEI871O4 Effective — expiration 09/2412013— 09/24/2019 Bond Western Surety Co Bond account no. 61814336 Active. Meets current requirements. $4,000.00 Received by L&I Effective date 09/24/2013 09/19/2013 Expiration date Until Canceled Savings No savings accounts during the previous 6 year period. License Violations Infraction no. EHUMI00560 Issue date 02/14/2017 Violation city BONNEY LAKE Type of violation ELECTRICAL CITATION Description Failing to get an inspection or obtain a valid electrical/telecommunications work permit or post a provisional electrical work permit prior to beginning the electrical/telecommunication installation or alteration as referenced in WAC 296-46B-901. Satisfied RCW/WAC 19.28.101 RCW Violation amount $250.00 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=603328920&LIC=JNMELEI87104&SAW= 10/1/2018 JNM Electric Inc Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID Account is current. 284,915-00 Doing business as JNM ELECTRIC INC Estimated workers reported Quarter 2 of Year 2018 "11 to 20 Workers" L&I account contact T3 / KENT ANDERSON (360)902-6963 • Email: ANDN235@lni.wa.gov Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bld No debarments have been issued against thls contractor. Workplace safety and health No inspections during the previous 6 year period. Page 2 of 2 Washington State Dept of Labor & industries Use of this site is subject to the laws of the stale of Washington, Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=603328920&LIC—INMELEI87104&SAW= 10/1/2018 0,0 tiWAT**2**. LANTERN LANDIN 1233 ANDOVER PARK E TUKWILA, WA 98188 140Changg of work v,fit.1- TtikwiIa NOTE: Flovscns vM and may includea. 717— ------ • > I- titr:C n pzEcccal tumbing C -Qs Piping Cli of Tu!;wila B.U111)!;`-.SCI flIVISEON • cope —.,val of ,7n n submittal fees. FILE CC -1r r43. Plan review approval 13 subject to Approval of construction documents C 3 the violation of any adopted code cr c..- . : '• t of approved Field Copy and conditior;s By: Date: City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA SEP 2 0 2018 PERRI' CENTER ELECTRICAL PAGES CE REVIEWED FOR COMPLIANWITH NFPA70 - NEC EO - COVER PAGE SEP 27 201B El - ONE LINE E2 - POWER PLAN City of Tukwila E3 - LIGHTING PLAN BUILDING DIVISION E4 - SITE LIGHTING E5 - BLDG ELEVATION E6 - BLDG ELEVATION � gi o 1 z 0 ri5 E ,-z d co c\I 0 8 „.. w g SJENNINGS CHECKED 1 /3/18 DATE RN LANDING DOVER PARK E LA, WA 98188 COVER PAGE NM ELECTRIC pendable. Efficient. Fast. ley Lake, WA 98391 (253) 439-8892 sheet EO 1 30) PSE TRANSFORMER EXISTING 750 KVA XFORMER 39100 AIC EXISITNG FEEDER EXISTING 1000A 120/208V 3PH CT 34141,AIC PANEL NAME HOUSE LOCATION: ELECTRICAL ROOM FED FROM: MAIN VOLTS; 120/208 PHASE: 3 WIRE; 4 BUSS AMPS; 100 BUSS TYPE: AL KAICSYM: 65 CONNECTED LOAD TYPE KVA RECEPT: 1.6 LIGHTING: 2,9 HEATING: 0,6 COOLING; 0 OTHER MOTORS: 0 LARGEST MOTOR: 0 KITCHEN EQUIP. 0 MISC.; 2.1 CONT. LOADS: 0 DEMAND LOAD Factor 50%-10KVA 125% 10096 096 100% 125% 100% 10096 25% KVA: 145 3.625 0.6 0 0 0 0 2.1 0 CODE REFERENCE 1NM ELECTRIC INC, 18808 88TH ST. E 220.13 BONNEY LAKE, WA 98391 2151, 220.11 253-439-8892 220.21 220.21 220.14, 430,24 430.24 220.2 220.1 215.2 (1) NOTES: KVA AMPS 7.2 20 20.825 57.84722 . T CKT. # DESCRIPTION PH AMP POLE LOAD KVA REC LTG HEAT COOL OTHER MOTOR LARGE MOTOR KIT MSCOTHER CONT. 1 INT BLDG LIGHTING A 20 1 1.4 1.4 o Z co 0 T N. SJENNINGS DRAWN SJENNINGS CHECKED 3 EXT BLDG LIGHTING 0 20 1 15 ,NDING PARK E 98188 1.5 5 MONUMENT SIGNAGE C 20 1 0.6 0.6 7 POLE LIGHTING A 20 1 0.8 0.6 LAN 123; TL 9 B E DIAGRAM 11 c 13 A sheet E1 z 0 15 B 17 C 19 A 21 B 23 C 25 A 27 B 29 C 31 A 33 B 35 C 37 A 39 B 41 C 2 FIRE ALARM A 20 1 1.6 1.6 4 BLDG SIGNAGE B 20 1 1.5 1.5 6 C 8 A 10 8 12 C 14 A 16 B 18 C 20 A 22 B 24 C 26 A 28 0 30 C 32 A 34 B 36 C 38 A 40 8 42 C 800AMP MAIN FUSED DISCONNECT 120/208V 3PH 65K AIC oo) 800AMP BUSS GUTTER 120/208V 3PH HOUSE PANEL 100A 120/208V 3PH BUSSING AND PANELS SERIES RATED AT 65k AIC #1/0 CU FEEDER SCHEDULE 1000 - (4) 4" C. W/ (4) #350MCM AL 800 - (3) 4" C. W/ (4) #400MCM AL 200 - (1) 2.5" C. W/ (4) #250MCM AL 100- (1) 1.5" C. W/(4)#1 AL Estimated Available Fault Current Calculator MAIN FEEDER LANTERN LANDING Secondary Voltage Total System Motor Load (HP) Primary Available Fault Current (A) Primary Voltage Transformer Rating (kVA) Nameplate Transformer Impedance (%Z) Rated Secondary Current (A) or Secondary Available Fault Current (A) Conductor Length (ft.) 208 1 1000 208 750 5.32 2082 39100 1 Size of Conductors 1350 Copper Aluminum In Conduit Cable Steel Non -Magnetic Number of Sets 0 0 0 4 Fault Current Available (A) 34,141 REVIEWED.FOR H OMPLIA NFPA70-NEC SEP 2 7 2010 City ofTulkwila BUILDING DIVISION MAIN BRANCH HOUSE RECEIVED CITY OF TUKWILA SEP 2 0 2018 PERMIT CENT.{ 20 0 0 0 3 30,656 20 1 0 0 14,604 . T 0 E ce o Z co 0 T N. SJENNINGS DRAWN SJENNINGS CHECKED CO o ,NDING PARK E 98188 LAN 123; TL E DIAGRAM INM ELI ependable. Edi iney Lake, WA c lid w sheet E1 z 0 (13D C.3 1 18'-6" 20• - 0" 1 20' - 0" 20' - 0" 20' - 0" 20'-0 42'-6" RTU 1 C FFE 26.53' RTU H-2 b l BLDG SIGNAGE 0 N • r FUTURE TENANT TENAN #2PANELS PANEL TENANT #1 — ----- r --�_— PANEL I J L — HOUSE PANEL 4 IrIgg RTU RTU 0 N FFE 26.53' BLDG SIGNA 12'-0" H-4 BLDG SIGNAGE PROJECT LIGHTING PLAN 1/8'=r-0' GFI 0 0.s 0 SHEET NOTE 1. EXISITNG CT AND METER LOCATION 2. NEW PANEL LOCATION 3. COORDINATE FINAL MECHANICAL LOCATIONS AND ELECTRICAL REQUIREMNTS WITH MECHANICAL CONTRACTOR 4. (3) 120V 20AMP DEDICATED RECEPTACLES (1) FIRE ALARM PANEL (1) PHONE BOARD (1) IRRIGATION CONTROLLER (1) RECEPTACLE UNDER PANEL 5. EXTERIOR INGROUND JBOX FOR SIGNAGE (PHOTOCELL CONTROL) 6. BUILDING SIGNAGE ON EXTERIOR LIGHTING CIRCUIT (PHOTOCELL CONTROL) ELL�fO�OLI REVIEWED .FOR COMPLIANCE WITH NEPA 70 - NEC SEP 2 7 2018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA SEP 2 0 2018 PERMIT CENTER � Q 1 Z O c/5 0 _d N 0 R. 8TCO SJENNINGS DRAWN SJENNINGS CHECKED M tc 1 LANDING /ER PARK E WA 98188 POWER PLAN JNM EI Dependable. 1 P.O. Box 7059 Bonney Lake, WI sheet E2 Ir 4, 18'-6" 20' - 0" 20' - 0" 20'.0' E A2' . 6„ FFE 26.53' FFE 26.53' LIGHTING PLAN L 1'•0' T E FIXTURE SCHEDULE A - 20FT SINGLE HEAD POLE LIGHT B - IN GROUND POWER BOX C - BOLLARD LIGHT D - LED ROPE LIGHITNG IN WINDOW E - LED ROPE LIGHTING UNDER AWNING F - LED SURFACE MOUNT DOWN LIGHT G - LED WALL PACK H - 4' LED STRIP OBO y REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC SEP 2 7 2018 City of Tukwila BUILDING DIVISIQN _ AEC E v Li CITY OF TUKWILA SEP 2 0 2018 PERMIT CENTER co C3 g M N 0 T R T SJENNINGS DRAWN SJENNINGS CHECKED �Q ro RN LANDING COVER PARK E LA, WA 98188 LIGHTING PLAN INM ELI ependable. Effi my Lake, WA 9 2 ®• A1.01 0 ENLARGED 18'-6" : 6'-6" 0 SITE PLAN NORTH 1aaaa laaapraiton aaaacow aaaaaaaaaaa EXIST. CURBLINE TO REMAIN IN PLACE PROJECT _JORTH 0,4010 00101, 0 6 A1.03 28'-0" V-0"---- 9' - 8" 4.6 9'- 10" 148'-0" 3' - 0" 6'-6" 3.4 a aCDaaaaaaaaCI= aaCIO aCOD aam11111111.aaCOI aaaaaaaaaa=ID II= aaa as 17'-6" 1 7'-0" 0'-9" 9'-11" • ae elpSao aaaaaaaaaa . mine. .a.®- a-aa®aant aamps amap +me.oto aa®a 0 CI" CID 1411111, bill, CD OD OD Clib =lb =lb elb CID 23'-10" CND DSCAPING- v is FT A1.01 •fie ENLARGED 0 SITE PLAN NORTH aoNsaaaa� EXIST. GAS VALVES TO REMAIN ALIGN NORTH -SOUTH CONTROL JOINTS WITH CENTERS OF DOORFRAMES AND MULLIONS. DERO "ROLLING RACK" BIKE RACK MODEL NO. RR2H COLOR: FLAT BLACK SURFACE MOUNT LIGHT BOLLARD FFE 26.53' FFE LANDING w 2 0 NEW POLE LIGHT AND HEAD SEE LIGHTING SCHEDULE ON LIGHTING PLAN FOR INFO EXI T. 24" LINDEN TR TO REMAIN EXIS . EXTERIOR CURBLINE TOR MAIN IN PLACE b M 1 3' - 9112" NEW LIGHT BOLLARD NEW LANDSCAPING EXIST. PARKING AREA TO BE RESURFACED (3 NEW CONCRETE PAD AND RAMP WITHIN EXISTING CURBLINE, $—ADA PARKING SIGN I SEE DETAILS 26 & 28/G0.06 CONTINUE NEW CU' IN ALIGNMENT WITH REMAINING CURBLI TO THE WEST B E NEW ACCESSIBLE PARKING STALL AND ALIGI4TMENT NO CHANGE TO TOPOGRAPHY D u 0 EXIST. CATCH BASIN TO REMAIN EXIST. WATER STAND PIPE AND POST INDICATOR VALVE TO REMAIN ELECT. SUPPLY FOR DEMOLISHED EXIST. PYLON SIGN TO REMAIN IN PLACE FOR REROUTE TO NEW MONUMENT SIGN LOCATION. cJ ca 3- V IM Sim 16 17 G0.06 ME Locpmo S REPAINT 5)(tST A, 0 NEW POLE LIGHT A D HEAD SEE LIGHTING SCH •ULE ON LIGHTING PLAN FOR NFO SIGNAGE JUNCTION BOX SEE LIGHTING SCHEDULE ON LIGHTING PLAN FOR INFO —EXIST. CURBLINE TO REMAIN IN PLACE EXIST. TELEPHONE MANHOLE TO REMAI EXIST. HYDRANT NEW LANDSCAPING— TO REMAIN — NEW POLE LIGHT AND HEAD —EXIST. UTILITY MANHOLES TO REMAIN INPLACE EDGE OF SIDEWALK I EXIST.TRAFFIC SIGNAL BOX TO REMAIN IN PACE r-+rr EXIST.WATER VALV REMAIN IN PLACE EXIST. TRAFFIC SIGNAGE TO REMAIN 1 ENLARGED SITE PLAN - SOUTH EXIST. POWER BOXES AND UTILITY VAULTS TO REMAIN EXIST. POWER AND UTILITY BOXES AND CONTROL PANELS TO REMAIN EXIST. TRAFFIC SIGNAL BOXES TO REMAIN EXIST. ROUND CONC. BOLLARD TO REMAIN EXIST. LIGHTING BOX TO REMAIN EXIST. TRAFFIC SIGNAL BOX TO REMAIN ENLARGED SITE PLAN LEGEND: NEW CONCRETE PAD, SIDEWALK, AND CURB SHEET NOTES: SEE LANDSCAPE PLAN FOR ADDITIONAL INFORMATION ON PLANTING TYPES AND LOCATIONS. 2. WHERE CONC. CONTROL JOINTS ARE NOT DIMENSIONED, ALIGN WITH EDGE OF ADJACENT BUILDING CONSTRUCTION AS INDICATED. Bo VIEWED FOR CO ` $ PLIANCE WIT '.FPA 70 -NEC SEP 27 2018 ity of Tukwila BU LDING DIVISIO 3116' =1'-0' RECEIVED CITY OF TUKWILA SEP 2 0 2018 ,PERMIT tis::'` i rr. ; H,R 1 z O rnE ,- d Z M CV O 17 ZT SJENNINGS DRAWN SJENNINGS CHECKED 1/3/18 DATE 1 LANDING /ER PARK E WA 98188 IEXTERIORLIGHTING AND POWER PLAN INM ELECTRIC ependable. Efficient. Fast rney Lake, WA 98391 e (253) 439-8892 sheet E4 .0 C C,L1AC.2)(C.3) ••• • WEST ELEVATION A4 01 • 1 J 1 H CZ 6 A4.01) E COLLECTOR AND DOWNSPOI.IT, TYP HARDIE PANEL REVEALS PLACED ATI4-0" 0c., TYP I G A4. - 0' , TYP. G6 G9( H j, 4-0"J, TYP. A H A 17 - 10 1/7 T.O. CANOPY FASCIA 10- r C L OF LIGHT FIXTURE 1 3 \A4.01 r LEVEL 1 oilL 0' - 0' \-w 20' - G' T.0 PARAPET 12-10 1/2" TO. CANOPY FASCIA SOUTH ELEVATION 1/8' = 1-0' TPO ROOF AND PRE - F !NIS E -ED GRAVEL STOP EDGE METAL IBI 1 1 B 10 12' - 10 1/2'' TO. HSS ok LEVEL 1 0' - 0" 7' • F 6 1 CANOPY BRACE SPACING 20' CENTERED WAN CANOPY ( 4 3 A40 • p.2X3.1 3) L CANOPY BRACE SPAC NG tl 4 T • 0.7) A ALIGN VERTICAL HARDIE REVEAL WITH CENTER OF STOREFRONT 1 C 1 A CENTER HARDIE PANEL OVER ENTRY DOOR A4 BRAKE MI: I AL WRAP AROUND NEW ROOF ':ASCIA PANTED TO MATCH COLOR "BLACK RASPBERRY" 17 - 10 1/71.0. HSS LEVEL 1 Au 0' - 0" \-w EAST ELEVATION 1/8* 1 0' A4.01 4-0 A4.0 CA 7' Y BRACE PACING 0' 2 - T.O. FASCIA A4.01 • r - BRAKE METAL WRAP / AROUND NEW ROOF FASCIA / PAINTED TO MATC-I CCLOR 'BLACK RASPBERRY' T ALIGN HARDIE REVEALS WITH WINDOW EDGES T / \ A4.01 T T La° I I 1 0 Lu \--CENTER HARD E PANEL OVER ENTRY DOOR • 0 La F - -I I 111 II 1 Fc -1 0 La Lr - I I r T T T T 1-188 BEAM VVRAFPED WITH RIGID INBJL AND PREFINISHED ALUM. BRAKE SHAPE MA I CH COLON "BLACK HASPBBRRY'' 0.71(-2\ 93) IG -r 1 F TYP. A401 4 C 7-- i 5.8 T.O. PARAPET -VERIFY Lf I I (-4- NORTH ELEVATION ea 'F \F A4.01 LEVELI £" 9 OLf REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC SEP 27 2018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TI.J KWH.", SEP 2 0 2018 (;.i I E 1 /3/1 8 DATE NO. REVISION DATE Cr:, cm 0 r,-. SJENNINGS DRAWN SJENNINGS CHECKED 1 LANDING /ER PARK E WA 98188 1--- Z < Ii- D INM ELECTRIC ependable. Efficient. Fast. iney Lake, WA 98391 - (253) 439-8892 -.1 ca -- 2017 9:47:04 AM \--EXISTING HIGH ROOF STRUCTURE TO REMAIN EXISTING RFCC MAIN TO — 111 VA;iCIAWATA, • T Ole a • C6�EAST - WEST BUILDING SECTION , 8. = 1'-. 15'-1" T.O. BEAM 4�(� A4.02 5.8 ) LEVEL 1 2 VieYA`IATAVi►`►�►7LTI►P►,1►,V. YAV 2 A4.01 I a L EAST - WEST BUILDING SECTION (-5` THROUGH LOW ROOF \ 1 I/8" = L 44-01 17-43/8"T,O.B—eAM 710 LEVELI 0'-0" (A) (A� 1 A4 C1 IIII1II1111I I11I EXISTING SPACE TO REMAIN NORTH -SOUTH BUILDING SECTION Ca"} 1/8' = 1'A' C7) re.) Sim B\I ^kY lrCl+1:4 .- .11t`y_(-a'-W.V. Y��l •--,.:./V4'.2Y.. /4. -Ne .;dpi _i Y`Nee..t S=.' NCN, r• 1 1 $ 1 NORTH - SOUTH BUILDING SECTION @ NORTH LANTERN 1/8' =1'•0' '`2 J} Sim 3 AAYU 5.8'i $16'•3"T.O.BEAM 12'-101/2"T.O.HSS EAST -WEST BUILDING SECTION AT S. LANTERN E- ; ve' = r.o. 1E) /—NEW ROOF AND / STR1J TURE F) 0 5 A4.01 24 - 6 T.O. BEAM 0 A4.02) 1 1 .W W4 0400,1, �11 A4.G.2) 02� 12'•1C1/2"T.O.HSS LEVEL 1 0' - 0" 15-1"T.O.BEAM LEVEL 1 0'-0" 3 \A4.01 WANK Aad z ;Or Tp10..416511, 06.0. 791f."74r4 0.1 'WOW MP rig "CIIK3•1 76' • :i 1/7' T n. BEAM 12'-101/2" T.O. HSS 1,F\151.,1__AL 0'-0" n e=mr-1 \ (0.8 X0.7 24-6'T.O. BEAM EXISTING ROOF STRUCTURE TO REMAIN EXISTING ROOF AND STRUCTURE WEST OF GRIDLINE 2TO REMAIN `--EXISTING GLULAM BEAM TO REMAN 26'-7"T.O, BEAM 5N 4_0%� 11E -31/4"T.O. EXIST. GLULAM 17 -101/2"T O. HSS —KAWNEER 601T STOREFRONT SYSTEM AT NORTH LANTERN 1 - EAST -WEST BUILDING SECTION THROUGH HIGH ROOF LEVEL 1 0'-0" 1/8" ELI 0 boy REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC SEP 2 7 2018 City of Tukwila BUILDING DIVISION 1-i EC EIVE -G: F OF -I..UKW'ILA SEP 2 U 2018 PERMIT CENTER REVISION T L co 0 T T a SJENNINGS DRAWN SJENNINGS CHECKED �~ ,-o ING CE 3 LAN 123 BLDG ELEVATION INM ELECTRIC ependable. Efficient. Fast. my Lake, WA 98391 0 (253) 439-8892 sheet E6