Loading...
HomeMy WebLinkAboutPermit D19-0286 - SABEY DATA CENTER / COLO 3 & 4 - CEILING TILE REPAIR, REPLACE CEILING GRID, NEW CEILING ETCSABEY DATA CENTER PROPERTIES 3433 120TH PL BLDG 4 D19-0286 Parcel No: Address: 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 1023049081 Permit Number: D19-0286 3433 S 120TH PL BLDG 4 Project Name: SABEY DATA CENTER PROPERTIES Issue Date: 10/16/2019 Permit Expires On: 4/13/2020 Owner: Name: Address: SABEY CORPORATION 12201 TUKWILA INTL BLVD 4TH FL , SEATTLE, WA, 98168 Contact Person: Name: GLENN PARRY Address: Contractor: Name: Address: License No: Lender: Name: Address: 12201 TUKWILA INTL BLVD , TUKWILA, WA, 98168 SABEY CONSTRUCTION INC 12201 TUKWILA INTL BLVD 4TH FLOOR, TUKWILA, WA, 98168-5121 SABEYCI033KM SABEY CORPORATION 12201 TUKWILA INTL BLVD 4TH FL , SEATTLE, WA, 98168 Phone: (206) 730-4983 Phone: (206) 281-4200 Expiration Date: 1/12/2021 DESCRIPTION OF WORK: REPLACE ANY DAMAGED OR STAINED CEILING TILE IN COLO 3 AS NEEDED. REMOVE AND REPLACE CEILING GRID AS NEEDED IN COLO 4 AREA. INTALL NEW CEILING TILE IN COLO 4. PATCH AND PAINT WALLS, INTALL NEW RUBBER BASE. Project Valuation: $115,875.00 Type of Fire Protection: Sprinklers: YES Fire Alarm: YES Type of Construction: VA Electrical Service Provided by: TUKWILA Fees Collected: $2,914.71 Occupancy per IBC: B Water District: 125 Sewer District: VALLEY VIEW Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Public Works Activities: Channe|izodon/Striping: [urbCut/Acces$Sidewa|k: Fire Loop Hydrant: Flood Control Zone: HauUnQ/OveoizeLoad: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: O Fill: 0 Number: O No Permit Center Authorized Signature: � Date-�� �~_� �o I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting nfthis permit does not presume to give authority to violate or cancel the provisions of any other state orlocal laws regulating construction orthe performance nfwork. |amauthorized tosign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: r /4,)_^l —, 7°^4f This permit shall become null and void if the work is not commenced within 180 days for the dateof issuance, or if the work is suspended orabandoned for aperiod of180days from the last inspection. PERMIT CONDITIONS: l: `BUILDING PERMIT CONDOOON5*** 2: Work shall beinstalled inaccordance withtheapprovedconstmctiondocuments,andanychanBesmade during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. S: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8'featinheight shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage orbracing shall beprepared byvregistered professional engineer licensed in the State ofWashington. Periodic special inspection- isrequired during anchorage ufstorage racks 8feet o,greater |nheight. 6: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based onsatisfactory completion nfthis requirement, 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued bythe City ofTukwila Building Department (2OG431'367O). 9: All electrical work shall beinspected and approved under aseparate permit issued bythe City nfTukwila Permit Center, 10: VALIDITY OFPERMIT: The issuance nrgranting ofapermit shall not bpconstrued tobeapennitfor,oran approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances ofthe City ufTukwila shall not bevalid. The issuance ofapermit based onconstruction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. ll: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (ZO6/43l'367U). 19: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building lsaltered, remodeled oradded to. Alterations to fire protection systems shall bedone inaccordance with applicable standards. (|F[9O1.4) 13: Sprinklers shall beinstalled under fixed obstructions over 4feet (12m)wide. (NFPA&3'O.6.S3.3) lZ: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval ofdrawings prior toinstallation ormodification. New sprinkler systems and all modifications tosprinkler systems involving more than 5Vheads shall have the written approval ufFactory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior tosubmittal tothe Tukwila Fire Prevention Bureau. Nusprinkler work shall commence without approved drawings, (City Ordinance No. 2436). 16: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or. partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #Z437) 15: All new fire alarm systems ormodifications toexisting systems shall have the written approval ofThe Tukwila Fire Prevention Bureau. Nowork shall commence until afire department pen -nit has been obtained. (City Ordinance #Z437)(|F[90l2) 14: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #Z436and #Z437) 17: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval ufsuch condition urviolation. lD: These plans were reviewed byinspector Sl1. |fyou have any questions, please call Tukwila Fire Prevention Bureau at(2O6)575'44O7. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (%D6)438'g35n 1700 DU|L0N5F|NAL*~ 0611 EMERGENCY LIGHTING 1400 FIRE FINAL 0409 FRAMING 0406 SUSPENDED CEILING CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. 1C - 03 Project No. Date Application Accepted: Date Application Expires: ? - — a 0 (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail. **Please Print** SITE INFORMATION King Co Assessor's Tax No.: 102304-9081 Site Address: 3433 South 120th Place Tukwila, WA 98168 Tenant Name: Sabey Data Center Properties Suite Number: COLO 3 and COLO 4 Floor: PROPERTY OWNER Name: Intergate Seattle 4 LLC .� Address: 12201 Tukwila International Blvd. , 4th floor City: Tukwila State: WA Zip: 98168 CONTACT PERSON — person receiving all project communication Name: Glenn Parry Address: 12201 Tukwila International Blvd. , 4th Floor City: Tukwila State: WA Zip: 98168 Phone: 206-730-4983 Email: glennp@sabey.com DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE Name: Leonard Ruff Address: 6210 36th Avenue N.E. City: Seattle State: WA Zip: 98115 Phone: 206-294-1288 Email: leonard.ruff@cascademissioncritical.com GENERAL CONTRACTOR INFORMATION Company Name: Sabey Construction Address: 12201 Tukwila International Blvd., 4th floor City: Tukwila State: WA Zip:98188 Phone: 206-281-8700 St Contr Reg No.: SABEYCI033KM Exp Date: 01/12/21 Tukwila Business License No.: BUS-0102122 New Tenant: 1st ❑ . Yes ®.. No ARCHITECT OF RECORD Company Name: Cascade Mission Critical Address: 6210 36th Avenue N.E. City: Seattle State: WA Zip:98115 Phone: 206-294-1288 Email: leonard.ruff@cascademissioncritical.com ENGINEER OF RECORD Company Name: nla Address: City: State: Zip: Phone: Email: LENDER — WHO IS FUNDING THE PROJECT (required for projects $5,000 or greater per RCW 19.27.095) Name: Sabey Corporation Address: 12201 Tukwila Int'I Blvd. --Fourth Floor City: Tukwila State: WA Zip: 98168 MONTHLY SERVICE BILLING -or- WATER METER REFUNDBILLING Name: Intergate Seattle 4 LLC Address: 12201 Tukwila Intl Blvd. - Fourth Floor City: Tukwila State: WA Zip: 98168 Phone: 206-281-8700 W:\Permit Center (Rachelle)\Applications\Word\Construction Permit Application Revised 6-2019.docx Revised: June 2019 Page 1 of 3 BUILDING DIVISION INFORMATION — 206-431-3670 Valuation of Project (contractor's bid price): $ 115,875.00 Existing Building Valuation: $ Describe the scope of work (please provide detailed information): Replace any damaged or stained ceiling tile in COLO 3 as needed. Remove and replace Ceiling grid as needed in COLO 4 area. Install new ceiling tile in COLO 4. Patch and paint walls, install new rubber base. Will there be new rack storage? 0.. Yes El.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC I' Floor 115,715 25,769 V-A, Sprinklered B 2°1 Floor 3" Floor Floors thru Basement Accessory Structure* Garage 0 Attached 0ched Carport 0 Attached 0 Detached Covered Deck Uncovered Deck PLANNING DIVISION ATION — 206-431- 670 Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Will there be a change in use? O.__ Yes Compact: Handicap: No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS — 206-575-4407 [XI Sprinklers 111 Automatic Fire Alarm 0 None 1111 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0.......Yes CJ No If 'yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets, S INFORMATION — 206-433-0179 0 ...Permanent Water Meter Size (1). 0 ...Temporary Water Meter Size (1). 0 ,..Water Only Meter Size 0 ...Sewer Main Extension WO # (2) " WO # (3) " WO # WO # (2) " WO # (3) " WO # D ........ Deduct Water Meter 0 ...Water Main Extension Public El Private 0 WO # Private 0 WAPcrmit Cantor (RachclIc)Applicat ions \Word \Construction Permit Application Revised G-20 I 9.clocx Revised June 2019 Page 2 of 3 PERMIT APPLICATION NOTES -- Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no pennit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AYTHO ENT: Signature: Print Name: Day Telephone: Date: 30 / 40 - 3 Y71- Mailing Address: ? 0 ( 70/11m 7ftri:-,01/0":ol 5/ 12/v L> /JAW/ /.9 /04 ?e7/6------ City State Zip W: \Permit Center (Rachelle)Applications \Word \Construction Permit Application Revised 6-2019.doex Revised: June 2019 Page 3 of 3 DESCRIPTIONS PermitTRAK Cash Register Receipt City of Tukwila I ACCOUNT QUANTITY PAID D19-0286 Address:'13433 S,120TH PL BLD n: 1023049081 $1,789.58 DEVELOPMENT $1,705.55 PERMIT FEE R000.322.100.00.00 0.00 $1,680.55 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $25.00 TECHNOLOGY FEE $84.03 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R18832 R000.322.900.04.00 0.00 $84.03 $1,789.58 Date Paid: Wednesday, October 16, 2019 Paid By: SABEY DATA CENTER ASSET HOLDIN Pay Method: CHECK 5443 Printed: Wednesday, October 16, 2019 11:38 AM 1 of 1 1? SYSTEMS DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $1,125.13 D19-0286 Address: 3433 5 120TH P1 BLDG 4 Apn: 1023049081 $1,125.13 Credit Card Fee $32.77 Credit Card Fee R000.369.908.00.00 0,00 $32.77 DEVELOPMENT $1,092.36 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R18466 R000.345,830.00.00 0.00 $1,092.36 $1,125.13 Date Paid: Friday, August 30, 2019 Paid By: MATTHEW MEILE Pay Method: CREDIT CARD 023060, 318862 Printed: Friday, August 30, 2019 12:09 PM 1 of 1 YSTEMS CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA 0017340000802374464500 Date: 08/30/2019 12:08:17 PM CREDIT CARD SALE VISA CARD NUMBER: TRAN AMOUNT: $125.13 APPROVAL CD: 318862 RECORD #: 000 CLERK ID: kandace X {CARDHOLDER'S SIGNATURE} I AGREE TO PAY THE ABOVE TOTAL AMOUNT ACCORDING TO THE CARD ISSUER AGREEMENT (MERCHANT AGREEMENT IF CREDIT VOUCHER) Thank you! Merchant Copy CO TUKWIL^ ET8AKIT 6200 SOVTVCENTEn BLVD TUnWzLx, WA 98188 206'433z870 CITY OF TUKWILo 0017348080802374464500 Date: 08/30/2019 I2:07:10 PM CREDIT CARD SALE MASTERCARD X {[AKn*VLDsn'S SIGNATURE} Z AGREE TO PAY THE ABOVE TOTAL AMOUNT ACCORDING TO THE [48D ISSUER AGREEMENT (MERCHANT AGREEMENT IF CREDIT VOUCHER) Thank you! Merchant Copy PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 INSPECTION RECORD Retain a copy with permit Project: Address: C.♦ pecrat Instructions: Type of Inspection: ate Called: Date Wanted: Requeste Phone No: i4: 2e94 — 2 55-- 347/ (206) 431-3670 proved per applicable codes. El Corrections required prior to approval. 11. COMMENTS: .IA A `Inspector Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. Pi~RMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: Address:. 3 j , , / :Date Called: Special Instructions: Date Wanted: a.m. p.m. Requester: Phone No: .040 .- 67 f Approved per applicable codes. C MENTS: Corrections required prior to approval. Inspector: Date: REINSPECTIt3N FEE REQUIRED. Prior to next inspection. fee must be paid at 63O0 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 5outhcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project Type of Inspectn: SUS Address: ©ate C ed: .,� Special Instructions: Date Wanted: "'."' �► a.m. p.m. Requester: Phone No: f - "v ' 36 7/ QApproved per applicable codes. © Corrections required prior to approval. COMMENTS: Inspector: REINSPECTJON FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Cast to schedule reinspection. COORD COP{ PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D19-0286 DATE: 08/30/19 PROJECT NAME: SABEY DATA CENTER PROPERTIES SITE ADDRESS: 3433 S 120TH PL BLDG 4 X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: Building Division I'`t` 11)[/ o 41 Puic Works MJ rola Fire Prevention Structural tV1(1 'Pt 614 1 Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 09/03/19 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 10/01/2019 Approved Corrections Required Approved with Conditions Denied (corrections entered in Reviews) (le: Zoning Issues) El Notation: REVIEWER'S INITIALS: DATE: PermitCenter Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire 0 Ping ❑ PW ❑ Staff Initials: 12/18/2013 Home Espanol Contact: Safety & Health Cal k Washington State Department of 4 Labor & Industries A-ZIndex Help Claims & Insurance Workplace Rights SABEY CONSTRUCTION INC Owner or tradesperson Principals SABEY, DAVID ARTHUR, PRESIDENT SEWELL, PATRICIA ANNE, SECRETARY POOLE, LAURENT D, SECRETARY (End: 01/19/2011) HARMON, JAMES N, TREASURER (End: 01/19/2011) Doing business as SABEY CONSTRUCTION INC WA UBI No. 601 532 164 12201 TUKWILA INTERNATIONAL BLVD 4TH FLOOR SEATTLE, WA 98168-5121 206-281-4200 KING County Business type Corporation Governing persons SABEY CORPORATION DAVID A SABEY; JOHN D SABEY; PATRICIA SEWELL; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active Meets current requirements. License specialties GENERAL License no. SABEYCI033KM Effective — expiration 05/14/1997— 01/12/2021 Bond HARTFORD FIRE INSURANCE CO Bond account no. 52BSBCQ3983 Received by L&I 12/20/2004 19!YrPr, National Fire Ins of Hartford Policy no. 2094061165 Received by L&I 03/20/2018 $12,000.00 Effective date 12/31/2004 Expiration date Until Canceled $1,000,000.00 Effective date 11/01/2016 My LE Trades & Licensing Help us improve 1 2 ,/ 4 5 6 7 8 9 10 11 VICINITY MAMAP/SIT EC DIRECTORY ' Y l E4. l l t, N H NORTH INDICATOR DETAIL XX NUMBER \AXXXJDRAWING -� NUMBER( 1 DETAIL XX NUMBER_ - DRAWING NUMBER G DETAIL CALLOUTS � x x � DRAWING NUMBER FOR CONTINUATION MATCH LINE F I I i EXISTING NEW GRID GRID COLUMN/BUILDING GRIDS 1 1 A 2 a PARTITION TYPE CALLOUT XXX E XXX ---- ELEVATION/DATUM CALLOUT EXISTING TO BE REMOVED NEW WORK IC _,. SECTION NUMBER AXXX DRAWING NUMBER SECTION CALLOUT ELEVATION )()( NUMBER DRAWING NUMBER EXTERIOR ELEVATION CALLOUT AELEVAT►ON NUMBER AXXX DRAWING NUMBER INTERIOR ELEVATION CALLOUT ROOM NAME XXXXX ROOM NUMBER ROOM NAME CALLOUT REVISION NUMBER SYMBOL & CLOUD O DOOR/OPENING NUMBER WXXX WINDOW NUMBER LXXX LOUVER NUMBER E XXXX EQUIPMENT CALLOUT F XXXX FURNITURE CALLOUT F XXXX FINISH CALLOUT OFIRE EXTINGUISHER SUPPLYAIR FE DIFFUSER -FIRE EXTINGUISHER FEC CABINET RETURN AIR GRILLE EXIT SIGN WALL MOUNTED lid FA EXIT SIGN F CEILING MOUNTED PUBLIC PA O ANNOUNCEMENT SPEAKER TROFFER FRECESSED FXJLIGHTING FIXTURE EPO EMERGENCY POWER OFF RECESSED CAN SWITCH FXO LIGHITNG FIXTURE RECESSED FX STRIP LIGHITNG FIXTURE SURFACE MOUNTED STRIP LIGHITNG FX FIXTURE FX WALL MOUNTED F� LIGHITNG FIXTURE A F S A AMP F FARENHEIT S SOUTH AB ANCHOR BOLT FA FIRE ALARM SA SUPPLYAIR AC ALTERNATING CURRENT FAB FABRICATE, FABRICATOR / FABRIC SC SOLID CORE ACC ACCESSIBLE FAC FACILITY SCHED SCHEDULE SO SMOKE DETECTOR, STORM DRAIN ACP ACOUSTICAL CEILING PANEL FACP FIRE ALARM CONTROL PANEL SECT SECTION ACT ACOUSTIC CEILING TILE FAS FIRE ALARM SYSTEM SGL SINGLE AD AREA DRAIN FB FLAT BAR SHT SHEET ADA AMERICANS WITH DISABILITIES ACT FC FURRING CHANNEL SHTGSHEATHING ADD ADDENDUM FCU FAN COIL UNIT SIM SIMILAR ADDN ADDITON FD FLOOR DRAIN SJ SIESMIC JOINT ADDL ADD TIONAL FDC FIRE DEPARTMENT CONNECTION SMACNA SHEET METAL AND AIRCONDITIONING ADJ ADJUSTABLE FDN FOUNDATION CONTRACTORS NATIONAL ASSOCIATION AFF ABOVE FINISHED FLOOR FE-X FIRE EXTINGUISHER, "X" DENOTES TYPE SMD SMOKE DAMPER AGGRAGGREGATE FEC-X FIRE EXTINGUISHER CABINET, "X" DENOTES TYPE SMR SHEET METAL ROOFING AHJ AUTHORITY HAVING JURISDICTION FGL FIBERGLAS SMP SHEET METAL PANEL SPD SOAP DISPENSER AHU AIR HANDLING UNIT FH FIRE HYDRANT SPECSPEC AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION FHC FIRE HOSE CABINET SPRINKL SPRINKL SPKLR ER ALT ALTERNATE FIG FIGURE SPKRSER ALUM ALUMINUM FIN FINISH, FINISHED SPR SINGLE NGLE PLY ROOFING ANCH ANCHOR FLASH FLASHING SQ SQUARE ANOD ANODIZED FLEX FLEXIBLE SR SERVER RACK AP ACCESS PANEL FLR FLOOR, FLOORING SS SERVICE SINK APPROX APPROXIMATE FLUOR FLUORESCENT SSM SOLID SURFACING MATERIAL AR ACID RESISTANT FO FINISHED OPENING SSTL STAINLESS STEEL ARCH ARCHITECT, ARCHITECTURAL FOIB FURNISHED BY OTHERS, INSTALLED BY OTHERS STC SOUND TRANSMISSION CLASS ASST ASSISTANT FDIC FURNISHED BY OTHERS, INSTALLED BY CONTRACTOR STL STEEL STORSTORAGE ASTM AMERICAN SOCIETY FOR TESTING MATERIALS FOW FACE OF WALL STRUCT STRUCTURE, STRUCTURAL ASSY ASSEMBLY FP FIRE PROOFING, FIRE PROTECTION SSHEET VINYL FLOORING ATM ATMOSPHERIC FPM FEET PER MINUTE SW W SIDEWALK ATS AUTOMATIC TRANSFER SWITCH FPS FEET PER SECOND SWBD SWITCHBOARD AUTO AUTOMAT FIR FIRE RATED, FIRE RATING SWG SWITCHGEAR AV AUDIO VISUAL FREQFREQUENCY AVE AVENUE FRTW FIRE RETARDANT TREATED WOOD T AVG AVERAGE FS FLOOR SINK T TREAD AWP ACOUSTICAL WALL PANEL FSD FIRE/SMOKE DAMPER TBB TELEPHONE BACKBOARD FT FOOT, FEET TBD TILE BACKER BOARD B FTG FOOTING TO TRENCH DRAIN BAL BALANCE F TO F FACE TO FACE TEL TELEPHONE TEMP TEMPERATURE, TEMPORARY BB BULLETIN BOARD FURRFURRING TERZ BC BATTERY CABINET FLIT T FUTURE TOONGUENGUETERRAZZO AND GROOVE BD BOARD FWC FABRIC WALL COVERING T HK THICK, THICKNESS BF BARRIER FREE FXD FIXED TO TOP OF BITM BITUMINOUS TPD TOILET PAPER DISPENSER BLCK BLOCKING G TS TUBE STEEL BLDG BUILDING GA GAUGE / GYPSUM ASSOCIATION TSTAT THERMOSTAT BLVD BOULEVARD GAL GALLON TV TELEVISION BM BENCH MARK GALV GALVANIZED TYP TYPICAL BO BOTTOM OF GB GRAB BAR U BOF BOTTOM OF FOOTING (FOUNDATION) GC GENERAL CONTRACTOR URINAL BOS BOTTOM OF STRUCTURE GEN GENERAL / GENERATOR OF UNDERFLOOR BOT BOTTOM GFRCGLASS FIBER REINFORCED CONCRETE UL UNDERWRITERS LABORATORIES BR BULLET RESISTIVE GFRG GLASS FIBER REINFORCED GYPSUM UNFIN UNFINISHED BRG BEARING GI GALVANIZED IRON UNGRD UNDERGROUND BRID BRIDGE, BRIDGING GL GLASS OR GLAZING UON UNLESS OTHERWISE NOTED BRKT BRACKET GLAMGLUE LAMINATED UPS UNITERRUPTIBLE POWER SUPPLY BRZ BRONZE GLP GYPSUM LATH AND PLASTER BS BOTH SIDES GSL GYPSUM SHAFT LINER V BSMT BASEMENT GWB GYPSUM WALLBOARD V VOLT VB VAPOR BARRIER BTUH BRITISH THERMAL UNITS PER HOUR GYP GYPSUM VC VIDEO CAMERA BTW BETWEEN VCT VINYL COMPOSITION TILE BUR BUILT UP ROOFING H VERTVERTICAL H HIGH VEST VESTIBULE C HB HOSE BIBB VIF VERIFY IN FIELD CAB CABINET HC HOLLOW CORE VNR VENEER CAP CAPACITY HD HAND DRYER VTF VNYL TILE FLOORING CB CATCH BASIN HDB HARD BOARD VWC VINYL WALL COVERING CEM CEMENT, CEMENTITIOUS HDF HIGH DENSITY FIBERBOARD CEM PL CEMENT PLASTER HDW HARDWARE W W WATT CER CERAMIC HDWDHARDWOOD HM HOLLOW METAL W WEST, WIDE CIF CUBIC FEET CFH CUBIC FEET PER HOUR HO HOLD OPEN HORIZHORIZONTAL WC WATER CLOSET CFLG COUNTERFLASHING HR HOUR WD WOOD CFM CUBIC FEET PER MINUTE HT HEIGHT WF WIDE FLANGE CFS CUBIC FEET PER SECOND HZ HERTZ FREQUENCY) WH WALL HYDRANT CG CORNER GUARD / CENTER OF GRAVITY HT HEIGHT[ WM WATER METER CH COAT HOOK HVAC HEATING, VENTILATION AND AIR CONDITIONING WMP WIRE MESH PARTITION CHAN CHANNEL W/O WTHOUT CHAM CHAMFER 1 WP WEATHER PROOF, WATER PROOF CI CAST IRON IBC INTERNATIONAL BUILDING CODE WWF WELDED WIRE FABRIC CIP CAST IN PLACE (CONCRETE) IC NTERCOM X CJ CONSTRUCTION JOINT CL CENTER LINE ID INSIDE DIAMETER EC NTERNATIONAL ENERGY CODE XRAY XRAY PROCESS OR MACHINE CLG CEILING IFC INTERNATIONAL FIRE CODE XFMR TRANSFORMER CLJ CONTROL JOINT IMC INTERNATIONAL MECHANICAL CODE �, CLOS CLOSET INCL INCLUDE, INCLUDING INFO INFORMATION YD YARD CLR CLEAR, CLEARANCE INSUL INSULATION CCLOSER TNT INTERIOR Z CMU MU CONCRETE MASONRY UNIT ]PC INTERNATIONAL PLUMBING CODE ZN ZINC CMP COMPOSITE METAL PANEL CO CLEAN OUT J COL COLUMN JAN JANITOR CTR COUNTER CTWRCOOLING TOWER CU CONDENSING UNIT CUB CUBIC CW COLD WATER CY CUBIC YARD d PENNY (NAILS) D DEEP db DECIBLES DEL DOUBLE DC DIRECT CURRENT DEG DEGREE(S) DEMODEMOLISH, DEMOLITION DEPT DEPARTMENT DET DETAIL DF DRINKING FOUNTAIN DIA DIAMETER DAG DIAGONAL DICA DRILLED IN CONCRETE ANCHOR DIFF DIFFUSER DIM DIMENSION(S) DIR DIRECTOR DISC DISCONNECT DSP DSPENSER DIV DIVISION DL DEADLOAD DMPF DAMP PROOF, DAMP PROOFING DIN DOWN DO DITTO DP DEEP DR DOOR/DRAIN DRC DOOR CONTACT DS DOWNSPOUT DW DISHWASHER DWG DRAWING DWL DOWEL DWR DRAWER DWTRDISTILLED WATER E EAST EA EXHAUSTAIR EB EXPANSION BOLT EF EXHAUSTFAN EJ EXPANSION JOINT EL ELEVATION ELEC ELECTRICAL ELEV ELEVATION / ELEVATOR SLIM ELIMINATE EMER EMERGENCY EPWREMERGENCY POWER ENAM ENAMELED) UNIT SECURITY RF RFID READER ENCL ENCLOSURE ENT ENGINEER CAMERA ENT ENTRANCE EP EXPLOSION PROOF CR CARD READER EPDXFL EPDXY FLOORING EPDXPT EPDXY PAINT EQ EQUAL EQUIPEQUIPMENT COMBINATION CARD EPO EMERGENCY POWER OFF CRB READER/BIOMETRIC ES EMERGENCYSH ESDF E ECTRO ST T COWER DI SAPATIVE FLOORING SCANNER EST ESTIMATED) ETC ET CETERRAA DC DOOR CONTACT ETR EXISTING TO REMAIN EVAC EVACUATE, EVACUATION EW EYE WASH EXAM EXAMINATION DB DURESS BUTTON EXC EXCAVATE, EXCAVATED, EXCAVATION EXH EXHAUST EXIST EXISTING IC INTERCOM EXP EXPOSED, EXPANSION EXT EXTERIOR EXTR EXTRUDED Fi­cc_j INTERCOM W/CAMERA PIR PASSIVE INFRARED DETECTOR MD MOTION DETECTOR PIN PIN PAD JS JANITOR'S SINK JT JOINT KIT KITCHEN KV KILO -VOLT KVA KLO-VOLT-AMPERE KW KILO -WATT L L LONG LAM LAMINATE, LAMINATED LAU LAUNDRY LAV LAVATORY LH LEFT HAND LHR LEFT HAND REVERSED LS LAG SCREW LT LIGHT LTG LIGHTING M MAS MASONRY MATL MATERIAL MAX MAXIMUM MDF MEDIUM DENSITY FIBERBOARD MDF(T) MAIN DISTRIBUTION FRAME -TELECOM MECH MECHANICAL MED MEDIUM MEMB MEMBRANE MEZZ MEZZANINE MFR MANUFACTURE, MANUFACTURER MGMT MANAGEMENT MH MANHOLE MIN MINIMUM, MINUTE MTS MANUAL TRANSFER SWITCH MP METAL PANEL MPOE MINIMUM POINT OF ENTRY (TELECOM) MS METAL STUD MVA MEGA -VOLT-AMPERE MVBL MOVABLE MW MEGA -WATT N N NORTH NEC NATIONAL ELECTRIC CODE NFPA NATONAL FIRE PROTECTION ASSOCIATION NIC NOT IN CONTRACT NOM NUMBER NOM NOMINAL NS NO SCALE NTS NOT TO SCALE 0 OC ON CENTER OD OUTSIDE DIAMETER OH OVERHEAD OFD OVERFLOW DRAIN OHD OVERHEAD DOOR OPNG OPENING OPP OPPOSITE OFRD OVERFLOW ROOF DRAIN OTS OPEN TO STRUCTURE ABOVE P PA PUBLIC ANNOUNCEMENT SYSTEM PB PUSH BUTTON PBD PARTICLE BOARD PC PRECAST PDU PLANTER DRAIN PDU POWER DISTRIBUTION UNIT PERP PERPINDICULAR PIR PASSIVE INFRARED DETECTOR PL PROPERTY LINE PLAM PLASTIC LAMINATE PLAS PLASTER PLYWD PLYWOOD PNL PANEL PR PAIR PRK PARK, PARKING PROP PROPERTY POC POINT OF CONNECTION PT PAINT, PAINTED, POINT, PRESSURE TREATED PTD PAPER TOWEL DISPENSER PTN PARTITION PVMT PAVEMENT Q QT QUARRYTILE R R RISER RA RETURN AIR RAID RADIUS RAF RAISED ACCESS FLOOR SYSTEM RD ROOF DRAIN, ROAD REF REFERENCE REFR REFRIGERATOR REINFREINFORCE, REINFORCING REQD REQUIRED REV REVISION RF RELIEF FAN RFG ROOFING RH RIGHT HAND RHR RIGHT HAND REVERSED RL RAIN LEADER RIM ROOM RO ROUGH OPENING RPM REVOLUTIONS PER MINUTE RPP REMOTE POWER PANEL RR RELAY RACK RTU RIGHT RTU ROOF TOP AIR CONDITIONING UNIT - i 5.1 t0 tt_ I F771 F7t1i M17 SITEv�v D 3433 S. 120TH PL. �I i 3353 mL---- - IN a i Li T NOT TO SCALE II PROJECTADDRESS 3433 SOUTH 120TH PLACE TUKWILA, WA 98168-5101 PARCEL NUMBER 102304-9081 LEGAL DESCRIPTION LOT 4 OF TUKWILA BLA L02-057 REC #20030327900002 LOCATED IN SE 1/4 OF SEC 9 & SW 1/4 10 OM 23-04, KING COUNTY, WA. ,. ,£ , �! E J' a i OWNER MECHANICAL ENGINEER ARCHITECTURAL SABEY CORPORATION HERMANSON, LLP 12201 TUKWILA INTERNATIONAL BLVD. 1221 2ND AVE NORTH GENERAL INFORMATION FOURTH FLOOR KENT, WA 98032 A-1101 OVERALL FLOOR PLAN MAIN PHONE: 206-281-8700 MAIN PHONE: 253-796-5873 EXITING PLAN CONTACT: JOHN FORD CONTACT: MARK GLODOWSKI A-102 COLO 3 DEMOLITION FLOOR EMAIL: JOHNF@SABEY.COM EMAIL: PLAN MGLODOWSKI@HERMANSON.COM A-103 COLO 4 DEMOLITION FLOOR PLAN ARCHITECT ELECTRICAL ENGINEER A-104 COLO 3 DEMOLITION CEILING CASCADE MISSION CRITICAL, LLC LANE COBURN ASSOCIATES PLAN 6210 36TH AVENUE N.E. 12900 N.E. 180TH STREET A-105 COLO 4 DEMOLITION CEILING SEATTLE, WA 98115 SUITE 201 PLAN MAIN PHONE: 206-294-1288 BOTHELL, WA 98011 A-106 COLO 3 FLOOR PLAN CONTACT: LEONARD A. RUFF, AIA MAIN PHONE: 206-425-368-4848 A-107 COLO 4 FLOOR PLAN PHONE: 206-294-1288 CONTACT: KEITH LANE, P.E. A-108 COLO 3 REFLECTED CEILING EMAIL: LEONARD.RUFF@CASCADE EMAIL: PLAN MISSIONCRITICAL.COM KLANE@LANECOBURN.COM A-109 COLO 4 REFLECTED CEILING PLAN STRUCTURAL ENGINEER A-301 COLO 4 CROSS SECTION ENGINEERS NORTHWEST, INC. GENERAL CONTRACTOR SCHEDULES 9725 THIRD AVENUE N.E. SABEY CONSTRUCTION A-501 DETAILS SUITE 207 12201 TUKWILA INTERNATIONAL SEATTLE, WA 98115 BLVD., 4TH FLOOR MAIN PHONE NO: 206-525-7560 SEATTLE, WA 98168-5121 CONTACT: DALE KAEMINGK, P.E. MAIN PHONE: 206-281-8700 EMAIL: CONTACT: GLENN PARRY MECHANICAL DALEK@ENGINEERSNW.COM SENIOR PROJECT MANAGER M0.00 LEGEND, ABBREVIATIONS, EMAIL: GLENNP@SABEY.COM GENERAL NOTES & SHEET INDEX-HVAC M0.01 SCHEDULES SHEET - HVAC M0.02 SEQUENCE OF OPERATIONS - HVAC M0.03 SEQUENCE OF OPERATIONS - HVAC M2.01 BD PARTIAL FIRST FLOOR DEMO PLAN B -HVAC M2.01CD PARTIAL FIRST FLOOR DEMO PLAN C - HVAC SCOPE O"'F WORK M2.01 B PARTIAL FIRST FLOOR PLAN B - HVAC M2.01 C PARTIAL FIRST FLOOR PLAN C - HVAC M6.01 MECHANICAL ENERGY CODE COMPLIANCE FORMS PROJECT DESCRIPTION THE PROJECT CONSISTS OF INTERIOR ARCHITECTURAL,MECHANICAL ELECTRICAL AND ELECTRICAL MPROVEMENTS INCLUDING HE INSTALLATION OF E0.01 COVER SHEET &DRAWING INDEX NEW RAISED FLOOR PANELS, NEW CEILING SYSTEMS, NEW HVAC E0. 02 SYMBOLS LEGEND, EQUIPMENTAND NEW ELECTRICAL EQUIPMENT IN AN EXISTING 25,769 S.F. ABBREVIATIONS &PROJECT SPACE. THERE ARE NO CHANGES TO EXITING. GENERAL NOTES E0.03 FEEDER & BRANCH CIRCUIT THE PROJECT WILL INCLUDE INTERIOR NON-STRUCTURAL DEMOLITION. SCHEDULES E3.01 PARTIAL LIGHTING PLAN E3.02 LIGHTING PHOTOMETRIC PLAN WORK UNDER THIS PERMIT E4.01 LIGHTING NAIRE SCHEDULE BUILDING PERMIT TO COVER NON-STRUCTURAL DEMOLITION AND AND COMPLLIAIA NCE FORM INTERIOR ARCHITECTURAL IMPROVEMENTS. WORK UNDER SEPARATE PERMITS MECHANICAL - BY CONTRACTOR ELECTRICAL - BY CONTRACTOR FIRE PROTECTION - BY CONTRACTOR CONTROL SYSTEMS - BY CONTRACTOR APPLICABLE CODES INTERNATIONAL BUILDING CODE, 2015 EDITION INTERNATIONAL FIRE CODE, 2015 EDITION INTERNATIONAL MECHANICAL CODE, 2015 EDITION INTERNATIONAL PLUMBING CODE, 2015 EDITION NATIONAL ELECTRIC CODE, 2014 EDITION WASHINGTON STATE ENERGY CODE, CURRENT EDITION LAND USE CODE INFORMATION TUKWILA MUNICIPAL CODE: TITLE 18: ZONING EXISTING ZONING DESIGNATION: MIC/H: MANUFACTURING INDUSTRIAL CENTER - HEAVY PROPOSED ZONING DESIGNATION: MIC/H, NO CHANGE CHANGE OF USE REQUIRED: NO NO CHANGES TO LAND USE OR PARKING BUILDING CODE INFORMATION EXISTING BUILDING AREA: 115,715 S.F. BUILDING OCCUPANCY GROUP: TYPE B, DATA CENTER & OFFICE: 108,288 SF TYPEA3, BREAK ROOM: 1,054 SF TYPE H3, RPU ENCLOSURES: 6,373 SF PREVIOUSLY PERMITTED UNDER UBC 1997 TYPE OF CONSTRUCTION: TYPE V-A, 1-HR, FULLY SPRINKLERED INTERIOR PROJECT AREA: 25,769 S.F. SEISMIC DESIGN CATEGORY: "D" 1. DO NOT SCALE THE DRAWINGS. 2. THE DRAWINGS AND SPECIFICATIONS ARE COMPLEMENTARY. WHAT IS SHOWN ON ONE SHALL BE CONSTRUED TO BE REQUIRED BY BOTH. 3. THE CONTRACTOR SHALL VERIFY ALL FIELD CONDITIONS PRIOR TO COMMENCING ANY WORK. NOTIFY THE ARCHITECT IMMEDIATELY IF ANY CONDITIONS IMPACT THE IMPLEMENTATION OF THE DESIGN INTENT. ALL EXISTING ELEMENTS SHOWN ON THE DRAWINGS ARE INCLUDED WITHOUTANY GUARANTEE OF ACCURACY. 4. ALL DIMENSIONS ARE SHOWN TO THE STRUCTURAL GRID OR FINISHED SURFACES, UNLESS NOTED OTHERWISE. 5. DETAILS ARE SHOWN ON THE DRAWINGS FOR THE FIRST OCCURANCE OF THE CONDITION AND ARE TYPICAL FOR ALL OTHER SIMILAR CONDITIONS. 6. PROVIDE A MINIMUM OF 6" FROM AN ADJACENT FINISHED SURFACE TO THE EDGE OF ANY FINISHED OPENING, DOOR FRAME OR WINDOW FRAME. 0 0 LL U s J J W on 0 Q C W = to at Lu poop E Q Q"t V LU � '} M � n Z NY rq F- z H J N z 0 E U o J ' J JLn -i .-t U 00­11 rn o N L Q 1A i— e'E W.— m ai Um ro N 00 0 c y 3 tncw3 cn�z3 0 c ao WU >(N p�'j Q cj• Q SEPARATE PERMIT U m t,p REPUIRED FOR: u) O 00 Mechanical Q o N N Electric®1 U O a ��1 Plumbing ff Gas Piping City of Tukwila BUILDING DIVISION REVISIONS No C!:<; "cS Sr,all be male to the scope of work wiTnout p- o' aporovai of the Tukwila Bwldtng Division. NOTE: Revisions will reauwre a new plan submittal and may include additional plan review. FILMO Permit No. Plan review approval is subject to errors and omissions. Approval of construction documents does nol allthoriZe the violation of any adopted code or ordinance Recelpi of approved Field Copy and cond,_uens is acknowiecoc: (--'^_ _ cO Orr K,"' REVIEWED FOR CODE COMPLIANCE APPROVED SEJP 24 20.19 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA AUG'3 0 20 PERMIT CENTER 0i Z z z0 t-i QJo U Q00u .J ` r_1 to � / Co o00 �O mZm rq 0) un�0 :, � J Lu `� O In co LLJ M 3 = Y m I_ W LLI z ISSUED/REVISED DATE PERMIT SUBMITTAL 8/22/19 PERMIT SET 8/28/19 GENERAL NOTES A-OL) COPYRIGHT @ CASCADE MISSION CRITICAL, LLC 2019 2 41 0 0 0 7 8 9 Fi 11 12 z G 10 i 0 I ----------------- - - - - - - - - - - - - - - - - - - - - - - -� i Q Q I Q Q Qj i I - ------ - - - - - - - - - -------------- - I- - - - - \`�- - - - ----- -q -f- - - -1 I ------------ -- --- ------+--------------- -----------f- - i----------�- - - - - - - 1- ----:--------------- :------------- :- - I- ---------.---\- - - - - - ,'----------- - M i COLO 1 i COLO 2! I COL6 3 /�! COLO 4 I I I r-I \ 01/) I r- - - - - t - - - - - - - - - = - - - - ---� - ---- - -r- - ----- � --T-t---------------- - - ----------------------------------k- - (----------1-- — .���\-oij----b---------------- -I - --- - - -- ----tII -IIII- - --/- -�II /--- )\) - II --------- t---------------- ---- +-----\----- ------------�I( -- a- i Ii----I---------------- _ I I I I N CiV ALL I I G PLAINU XII G LA EXITING NOTES NO CHANGE TO EXISTING EXITING. EXITING DISTANCES D1 = MAXIMUM DIAGONAL DISTANCE OF SPACE: 227' - 10 1/2" SEPARATION OF EXITS REQUIRED = 1/2 DIAGONAL DISTANCE = 113' - 11" D2 = EXIT SEPARATION DISTANCE = 182' - 3" D3 = EXIT SEPARTION DISTANCE = 178' - 0 1/2" Q Q -'f'.- --- - - - -�-- ------ I COLO 1 i - --------------- Ila i I I ------------ +----------------- +------------- --------------0 I I j COLO 6 j - - - - +----------------+ - - - - - - - - - -mx I � I j I - - - - ----------------i---------- ----------------------- COLO 5 j ------------ t---------------- t---------- - - - - - - - - - -O I I 001, -----0 \ I I I \ \--- PROJECTAREA: 25,769 SF REVIEWED FOR CODE COMPLIANCE APPROVED SEP 24 2019 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA AUG 3 0 20S 13ERMIT CENTER 0 0 LL U J � J d' -o W m J 0 Q N W � cn `a 1000 UJ W 00 E Q �Qm o W (jr x�ov W r m 0 0 r z J z 0 v E JO J � J b Q ,0 m o F_❑� a v � 0 0 `n Cncw3 a c00 0 WV jH V V M l0 Ln O.O Vo oa R:* 0 z z O O 0 Q d, J>cz tvLn d 50 = � o � mzm "� V)cc00 E-¢ --J -j UJ N U m ' F- Q d re a W Z ISSUED/REVISED DATE PERMIT SUBMITTAL 8/22/19 PERMIT SET 8/28/19 8 COPYRIGHT © CASCADE MISSION CRITICAL, LLC 2019 OVERALL BUILDING PLAN EXITING PLAN 1 2 3 .19 9 on 7 91 9 10 11 12 G F E 10 i A103 e I I I I I I I I MMMONIMM COLO 3: DEMOLITION FLOOR PLAN SCALE: 1/8" = V-0" DEFINITIONS REMOVE: DETACH ITEMS FROM EXISTING CONSTRUCTION AND DISPOSE OF THEM OFF SITE UNLESS INDICATED OTHERWISE TO BE SLAVAGED OR REINSTALLED. REMOVE AND SALVAGE: DETACH ITEMS FROM EXISTING CONSTRUCTION, IN A MANNER TO PREVENT DAMAGE, AND DELIVER TO OWNER READY FOR REUSE. REMOVE AND REINSTALL: DETACH ITEMS FROM EXISTING CONSTRUCTION, IN A MANNER TO PREVENT DAMAGE, PREPARE FOR REUSE, AND REINSTALL WHERE INDICATED. EXISTING TO REMAIN: LEAVE EXISTING ITEMS THAT ARE NOT TO BE REMOVED AND THAT ARE NOT OTHERWISE INDICATED TO BE SALVAGED OR REINSTALLED. DISMANTLE: TO REMOVE BY DISASSEMBLING OR DETACHING AN ITME FROM A SURFACE, USING GENTLE METHODS AND EQUIPMENT TO PREVENT DAMAGE TO THE ITEM AND SURFACES; DISPOSING OF ITEMS UNLESS INDICATED TO BE SLAVAGED OR REINSTALLED. DEMOLITION NOTES 1. NOTALL RAISED FLOOR PANELS TO BE REMOVED ARE INDICATED ON DRAWINGS. REFER TO DEMOLITION KEY FOR DESCRIPTIONS OF PANELS TO BE REMOVED. CONTRACTOR SHALL FIELD VERIFY EXTENT OF RAISED FLOOR DEMOLITION AND QUANTITIES OF PANELS AND OTHER COMPONENTS TO BE REMOVED. 2. UNLESS OTHERWISE NOTED, REMOVE COMPLETE ASSEMBLIES TO LEAVE THE AREA IN A CLEAN CONDITION. 3. PATCH AND REPAIR ANY EXISTING MATERIALS OR ASSEMBLIES TO REMAIN IF DAMAGED DURING DEMOLITION. 4. COORDINATE ALL DEMOLITION ACTIVITIES FORALL DISCIPLINES AS SHOWN ON OTHER DRAWINGS OR CALLED FOR IN OTHE SPECIFICATION SECTIONS. 5. REMOVE ALL REMAINING BASE PLATES, ANCHORAGES, ETC., FROM EXISTING EQUIPMENT BASES, INCLUDING ANY METAL FRAMING OR ANCILLARY SUPPORTS. 6. THROUGHLY CLEAN THE UNDERFLOOR SPACE OF ANY EXCESS MATERIAL OR DEBRIS. 7. REMOVE ALL WALL MOUNTED METAL CHANNEL SUPPORT FRAMING. 8. DO NOT CUT OR DRILL EXISTING CONCRETE SLAB WITHOUT OWNER'S APPROVAL. IF REINFORCING STEEL IS ENCOUNTERED, IMMEDIATELY CEASE DRILLING OR CUTTING OPERATION AND ADJUST LOCATION OF THE OPERATION TO AVOID DAMAGE TO REINFORCING STEEL. PATCH THE UNUSED HOLE OR CUTTING SLOT WITH NON -SHRINK CONCRETE PATCHING MATERIAL. 9. VERIFY THAT EXISTING UTILITIES SERVING THE SPACE HAVE BEEN DISCONNECTED AND CAPPED BEFORE STARTING DEMOLITION ACTIVITIES. COORDINATE WITH THE OWNER ON ALL SHUTOFFS OF UTILITY POWER IN ANYAREA PRIOR TO SHUTTING OFF ANY UTILITY. 10. VERIFY THAT ANY HAZARDOUS MATERIALS HAVE BEEN REMEDIATED BEFORE PROCEEDING WITH DEMOLITION OPERATIONS. 11. PROVIDE TEMPORARY BARRICADES AND OTHER PROTECTION AS REQUIRED TO PREVENT INJURY TO PEOPLE. TEMPORARY BARRICADES SHALL REMAIN IN PLACE AS LONG AS POTENTIALLY HAZARDOUS CONDITIONS REMAIN. 12. DEMOLISH AND REMOVE EXISTING CONSTRUCTION ONLY TO THE EXTENT REQUIRED BY NEW CONSTRUCTION AND AS INDICATED. USE METHODS TO COMPLETE THE WORK WITHIN LIMITATIONS OF GOVERNING REGULATIONS AND OWNER'S WORK RULES. 13. COORDINATE WITH THE OWNER FOR CONDUCT OF DEMOLITION ACTIVITIES TO MINIMIZE DISRUPTION TO EXISTING TENANTS AND USERS OF THE BUILDING. DO NOT CONDUCTANY FLAME CUTTING, WELDING, GRINDING OR OTHER OPERATION THAT COULD POTENTIALLY TRIGGER THE FIRE ALARM SYSTEM OR INCIPIENT SMOKE DETECTION SYSTEM WITH SPECIFIC WRITTEN APPROVAL FROM THE OWNER. COORDINATE WITH THE OWNER IF FIRE ALARM SYSTEMS ARE REQUIRED TO BE DISABLED OR PLACED IN TEST MODE IN ANY SPACE. �R z Q J D Z 0 U 5 E U ° J J f0 V Q u Q N fY •� N v v Uo m � 0 0 V) LL 3 3 v c oo C oo r4 N N W U �:. ,..i v Qv Q C t m UU mN tD Qao� `� a UO �a DEMOLITION KEY ::I- O GENERAL RAISED FLOOR DEMOLITION: REMOVE ALL RAISED FLOOR PANELS WITH HOLES, Q CABLE CUTOUTS, OR GROMMETS. EXISTING STRINGERS AND PEDESTALS TO REMAIN, EXCEPT AS NECESSARY TO z ACCOMMODATE NEW WORK. O REMOVE EXISTING PERFORATED RAISED FLOOR PANELS. NOTE, ONLY GENERALAREA z O OF PERFORATED RAISED FLOOR PANELS TO BE REMOVED IS INDICATED. REMOVE ALL PERFORATED PANELS. c) d- 3� REMOVE EXISTING RAISED FLOOR PANELS WITH RECESSED ELECTRICAL BOXES. NOTE, ONLY GENERALAREA OF PANELS WITH RECESSED ELECTRICAL BOXES IS j = O p6 INDICATED. REMOVE ALL PANELS WITH RECESSED ELECTRICAL BOXES. CO z fM ® REMOVE EXISTING STRINGERS AND/OR PEDESTALS TO ALLOW FOR W (/) INSTALLATION OF NEW EQUIPMENT. Ln 1= O 5O REMOVE ANY EXISTING EQUIPMENT FRAME, BASE PLATES, ANCHOR BOLTS, Q r-1 '--I AND MISC. FRAMING. W O © REMOVE EXIST. RESILIENT BASE. UNLESS OTHERWISE NOTED, REMOVE Uj L1J Ln U ALL BASE ON INDICATED WALL. Q 70 REMOVE EXIST. EMERGENCY KIOSK, IF NECESSARY FOR NEW WORK. Q PROTECTAND RETAIN FOR RE -INSTALLATION. d 0 ® EXIST. MECHANICAL UNIT STAND TO REMAIN. REMOVE ANY LOOSE PLATES, BOLTS, ETC. LU THAT ARE NOT PHYSICALLY ATTACHED TO THE STAND. z REVIEWED FOR CODE COMPLIANCE APPROVED SEP 24 2019 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA AUG 3 0 2019 PERMIT CENTER m ISSUED/REVISED D TA E PERMITSUBMITTAL 8122119 PERMIT SET 8/28/19 COPYRIGHT n CASCADF MISSION CRITICAI I I 2019 COLO 3 DEMOLITION FLOOR PLAN E 0 0 L7 5 l7 7 0 In ff Ti I XL 19 FBI CN IV■ 90 N COLO 3: DEMOLITION FLOOR PLAN SCALE: 1/8" = V-0" DEFINITIONS DEMOLITION NOTES REMOVE: DETACH ITEMS FROM EXISTING CONSTRUCTION AND DISPOSE OF THEM OFF SITE UNLESS 1. NOTALL RAISED FLOOR PANELS TO BE REMOVED ARE INDICATED ON DRAWINGS. INDICATED OTHERWISE TO BE SAAVAGED OR REINSTALLED. REFER TO DEMOLITION KEY FOR DESCRIPTIONS OF PANELS TO BE REMOVED. CONTRACTOR SHALL FIELD VERIFY EXTENT OF RAISED FLOOR DEMOLITION AND REMOVE AND SALVAGE: DETACH ITEMS FROM EXISTING CONSTRUCTION, IN A MANNER TO PREVENT QUANTITIES OF PANELS AND OTHER COMPONENTS TO BE REMOVED. DAMAGE, AND DELIVER TO OWNER READY FOR REUSE. 2. UNLESS OTHERWISE NOTED, REMOVE COMPLETE ASSEMBLIES TO LEAVE REMOVE AND REINSTALL: DETACH ITEMS FROM EXISTING CONSTRUCTION, IN A MANNER TO PREVENT THE AREA IN A CLEAN CONDITION. DAMAGE, PREPARE FOR REUSE, AND REINSTALL WHERE INDICATED. 3. PATCH AND REPAIR ANY EXISTING MATERIALS OR ASSEMBLIES TO REMAIN EXISTING TO REMAIN: LEAVE EXISTING ITEMS THAT ARE NOT TO BE REMOVED AND THAT ARE NOT IF DAMAGED DURING DEMOLITION. OTHERWISE INDICATED TO BE SALVAGED OR REINSTALLED. 4. COORDINATE ALL DEMOLITION ACTIVITIES FOR ALL DISCIPLINES AS SHOWN DISMANTLE: TO REMOVE BY DISASSEMBLING OR DETACHING AN ITME FROM A SURFACE, USING GENTLE ON OTHER DRAWINGS OR CALLED FOR IN OTHE SPECIFICATION SECTIONS. METHODS AND EQUIPMENT TO PREVENT DAMAGE TO THE ITEM AND SURFACES; DISPOSING OF ITEMS UNLESS INDICATED TO BE SLAVAGED OR REINSTALLED. 5. REMOVE ALL REMAINING BASE PLATES, ANCHORAGES, ETC., FROM EXISTING EQUIPMENT BASES, INCLUDING ANY METAL FRAMING OR ANCILLARY SUPPORTS. 6. THROUGHLY CLEAN THE UNDERFLOOR SPACE OF ANY EXCESS MATERIAL OR DEBRIS. 7. REMOVE ALL WALL MOUNTED METAL CHANNEL SUPPORT FRAMING. 8. DO NOT CUT OR DRILL EXISTING CONCRETE SLAB WITHOUT OWNER'S APPROVAL. IF REINFORCING STEEL IS ENCOUNTERED, IMMEDIATELY CEASE DRILLING OR CUTTING OPERATION AND ADJUST LOCATION OF THE OPERATION TO AVOID DAMAGE TO REINFORCING STEEL. PATCH THE UNUSED HOLE OR CUTTING SLOT WITH NON -SHRINK CONCRETE PATCHING MATERIAL. 9. VERIFY THAT EXISTING UTILITIES SERVING THE SPACE HAVE BEEN DISCONNECTED AND CAPPED BEFORE STARTING DEMOLITION ACTIVITIES. COORDINATE WITH THE OWNER ON ALL SHUTOFFS OF UTILITY POWER IN ANYAREA PRIOR TO SHUTTING OFF ANY UTILITY. 10. VERIFY THAT ANY HAZARDOUS MATERIALS HAVE BEEN REMEDIATED BEFORE PROCEEDING WITH DEMOLITION OPERATIONS. 11. PROVIDE TEMPORARY BARRICADES AND OTHER PROTECTION AS REQUIRED TO PREVENT INJURY TO PEOPLE. TEMPORARY BARRICADES SHALL REMAIN IN PLACE AS LONG AS POTENTIALLY HAZARDOUS CONDITIONS REMAIN. 12. DEMOLISH AND REMOVE EXISTING CONSTRUCTION ONLY TO THE EXTENT REQUIRED BY NEW CONSTRUCTION AND AS INDICATED. USE METHODS TO COMPLETE THE WORK WITHIN LIMITATIONS OF GOVERNING REGULATIONS AND OWNER'S WORK RULES. 13. COORDINATE WITH THE OWNER FOR CONDUCT OF DEMOLITION ACTIVITIES TO MINIMIZE DISRUPTION TO EXISTING TENANTS AND USERS OF THE BUILDING. DO NOT CONDUCTANY FLAME CUTTING, WELDING, GRINDING OR OTHER OPERATION THAT COULD POTENTIALLY TRIGGER THE FIRE ALARM SYSTEM OR INCIPIENT SMOKE DETECTION SYSTEM WITH SPECIFIC WRITTEN APPROVAL FROM THE OWNER. COORDINATE WITH THE OWNER IF FIRE ALARM SYSTEMS ARE REQUIRED TO BE DISABLED OR PLACED IN TEST MODE IN ANY SPACE. I UNW--al DEMOLITION KEY 1U GENERAL RAISED FLOOR DEMOLITION: REMOVE ALL RAISED FLOOR PANELS WITH HOLES, CABLE CUTOUTS, OR GROMMETS. EXISTING STRINGERS AND PEDESTALS TO REMAIN, EXCEPT AS NECESSARY TO ACCOMMODATE NEW WORK. O REMOVE EXISTING PERFORATED RAISED FLOOR PANELS. NOTE, ONLY GENERALAREA OF PERFORATED RAISED FLOOR PANELS TO BE REMOVED IS INDICATED. REMOVE ALL PERFORATED PANELS. 3� REMOVE EXISTING RAISED FLOOR PANELS WITH RECESSED ELECTRICAL BOXES. NOTE, ONLY GENERALAREA OF PANELS WITH RECESSED ELECTRICAL BOXES IS INDICATED. REMOVE ALL PANELS WITH RECESSED ELECTRICAL BOXES. ® REMOVE EXISTING STRINGERS AND/OR PEDESTALS TO ALLOW FOR INSTALLATION OF NEW EQUIPMENT. 5� REMOVE ANY EXISTING EQUIPMENT FRAME, BASE PLATES, ANCHOR BOLTS, AND MISC. FRAMING. © REMOVE EXIST. RESILIENT BASE. UNLESS OTHERWISE NOTED, REMOVE ALL BASE ON INDICATED WALL. 7O REMOVE EXIST. EMERGENCY KIOSK, IF NECESSARY FOR NEW WORK. PROTECTAND RETAIN FOR RE -INSTALLATION. ® EXIST. MECHANICAL UNIT STAND TO REMAIN. REMOVE ANY LOOSE PLATES, BOLTS, ETC. THAT ARE NOT PHYSICALLY ATTACHED TO THE STAND. REVIEWED FOR CODE COMPLIANCE APPROVED SEP 24 2019 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA AUG 3 0 2019 PERMIT CENTER a O U. U c J J � d' -n W m J c c Q m W N v� Uj ono omo E E— a)0)o W m� h z W m ~ oYON 3 o z tit2-a 3 z J V) z 0 U E U ° J J U Ln G Q 00 u 00 C U mo Q E �'y Qj a a a UQ m u N 0 V) 3 cnoz3 m c c 00 0 c 00 Wv ja Q� �N U6 mLo QQON a UQQ ka 11* O z U o _z QQd' co H: J>06 =O s W o mzm � CN 00 ��O Q 0 J LUO UJ v) �QU � m d W F_ z ISSUED/REVISED DATE PERMIT SUBMITTAL 8/22119 PERMIT SET 8/28/19 COPYRIGHT @C CASCADE MISSION CRITICAL, LLC 2019 COLO 3 DEMOLITION FLOOR PLAN t I 0 I in 5 9 t% 11 12 I 11 10 III C A N COLO 4: DEMOLITION FLOOR PLAN SCALE: 1/8" = 1'-0" REMOVE: DETACH ITEMS FROM EXISTING CONSTRUCTION AND DISPOSE OF THEM OFF SITE UNLESS INDICATED OTHERWISE TO BE SAAVAGED OR REINSTALLED. REMOVE AND SALVAGE: DETACH ITEMS FROM EXISTING CONSTRUCTION, IN A MANNER TO PREVENT DAMAGE, AND DELIVER TO OWNER READY FOR REUSE. REMOVE AND REINSTALL: DETACH ITEMS FROM EXISTING CONSTRUCTION, IN A MANNER TO PREVENT DAMAGE, PREPARE FOR REUSE, AND REINSTALL WHERE INDICATED. EXISTING TO REMAIN: LEAVE EXISTING ITEMS THAT ARE NOT TO BE REMOVED AND THAT ARE NOT OTHERWISE INDICATED TO BE SALVAGED OR REINSTALLED. DISMANTLE: TO REMOVE BY DISASSEMBLING OR DETACHING AN ITME FROM A SURFACE, USING GENTLE METHODS AND EQUIPMENT TO PREVENT DAMAGE TO THE ITEM AND SURFACES; DISPOSING OF ITEMS UNLESS INDICATED TO BE SAAVAGED OR REINSTALLED. DEMOLITION NOTES 1. NOT ALL RAISED FLOOR PANELS TO BE REMOVED ARE INDICATED ON DRAWINGS. REFER TO DEMOLITION KEY FOR DESCRIPTIONS OF PANELS TO BE REMOVED. CONTRACTOR SHALL FIELD VERIFY EXTENT OF RAISED FLOOR DEMOLITION AND QUANTITIES OF PANELS AND OTHER COMPONENTS TO BE REMOVED. 2. UNLESS OTHERWISE NOTED, REMOVE COMPLETE ASSEMBLIES TO LEAVE THE AREA IN A CLEAN CONDITION. 3. PATCH AND REPAIRANY EXISTING MATERIALS OR ASSEMBLIES TO REMAIN IF DAMAGED DURING DEMOLITION. 4. COORDINATE ALL DEMOLITION ACTIVITIES FORALL DISCIPLINES AS SHOWN ON OTHER DRAWINGS OR CALLED FOR IN OTHE SPECIFICATION SECTIONS. 5. REMOVE ALL REMAINING BASE PLATES, ANCHORAGES, ETC., FROM EXISTING EQUIPMENT BASES, INCLUDING ANY METAL FRAMING OR ANCILLARY SUPPORTS. 6. THROUGHLY CLEAN THE UNDERFLOOR SPACE OF ANY EXCESS MATERIAL OR DEBRIS. 7. REMOVE ALL WALL MOUNTED METAL CHANNEL SUPPORT FRAMING. 8. DO NOT CUT OR DRILL EXISTING CONCRETE SLAB WITHOUT OWNER'S APPROVAL. IF REINFORCING STEEL IS ENCOUNTERED, IMMEDIATELY CEASE DRILLING OR CUTTING OPERATION AND ADJUST LOCATION OF THE OPERATION TO AVOID DAMAGE TO REINFORCING STEEL. PATCH THE UNUSED HOLE OR CUTTING SLOT WITH NON -SHRINK CONCRETE PATCHING MATERIAL. 9. VERIFY THAT EXISTING UTILITIES SERVING THE SPACE HAVE BEEN DISCONNECTED AND CAPPED BEFORE STARTING DEMOLITION ACTIVITIES. COORDINATE WITH THE OWNER ON ALL SHUTOFFS OF UTILITY POWER IN ANYAREA PRIOR TO SHUTTING OFF ANY UTILITY. 10. VERIFY THATANY HAZARDOUS MATERIALS HAVE BEEN REMEDIATED BEFORE PROCEEDING WITH DEMOLITION OPERATIONS. 11. PROVIDE TEMPORARY BARRICADES AND OTHER PROTECTION AS REQUIRED TO PREVENT INJURY TO PEOPLE. TEMPORARY BARRICADES SHALL REMAIN IN PLACE AS LONG AS POTENTIALLY HAZARDOUS CONDITIONS REMAIN. 12. DEMOLISH AND REMOVE EXISTING CONSTRUCTION ONLY TO THE EXTENT REQUIRED BY NEW CONSTRUCTION AND AS INDICATED. USE METHODS TO COMPLETE THE WORK WITHIN LIMITATIONS OF GOVERNING REGULATIONS AND OWNER'S WORK RULES. 13. COORDINATE WITH THE OWNER FOR CONDUCT OF DEMOLITION ACTIVITIES TO MINIMIZE DISRUPTION TO EXISTING TENANTS AND USERS OF THE BUILDING. DO NOT CONDUCTANY FLAME CUTTING, WELDING, GRINDING OR OTHER OPERATION THAT COULD POTENTIALLY TRIGGER THE FIRE ALARM SYSTEM OR INCIPIENT SMOKE DETECTION SYSTEM WITH SPECIFIC WRITTEN APPROVAL FROM THE OWNER. COORDINATE WITH THE OWNER IF FIRE ALARM SYSTEMS ARE REQUIRED TO BE DISABLED OR PLACED IN TEST MODE IN ANY SPACE. N ELECTRICAL 189 DEMOLITION KEY O GENERAL RAISED FLOOR DEMOLITION: REMOVE ALL RAISED FLOOR PANELS WITH HOLES, CABLE CUTOUTS, OR GROMMETS. EXISTING STRINGERS AND PEDESTALS TO REMAIN, EXCEPT AS NECESSARY TO ACCOMMODATE NEW WORK. O REMOVE EXISTING PERFORATED RAISED FLOOR PANELS. NOTE, ONLY GENERALAREA OF PERFORATED RAISED FLOOR PANELS TO BE REMOVED IS INDICATED. REMOVE ALL PERFORATED PANELS. 3t D REMOVE EXISTING RAISED FLOOR PANELS WITH RECESSED ELECTRICAL BOXES. NOTE, ONLY GENERALAREA OF PANELS WITH RECESSED ELECTRICAL BOXES IS INDICATED. REMOVE ALL PANELS WITH RECESSED ELECTRICAL BOXES. ® REMOVE EXISTING RAISED FLOOR PANELS, STRINGERS AND/OR PEDESTALS TO ALLOW FOR INSTALLATION OF NEW EQUIPMENT. 5O REMOVE EXISTING EQUIPMENT FRAME, BASE PLATES, ANCHOR BOLTS, AND MISC. FRAMING. © REMOVE EXIST. RESILIENT BASE. UNLESS OTHERWISE NOTED, REMOVE ALL BASE ON INDICATED WALL. 7U REMOVE EXIST. EMERGENCY KIOSK, IF NECESSARY FOR NEW WORK. PROTECTAND RETAIN FOR RE -INSTALLATION. ® EXIST. MECHANICAL UNIT STAND TO REMAIN. REMOVE ANY LOOSE PLATES, BOLTS, ETC. THAT ARE NOT PHYSICALLY ATTACHED TO THE STAND. 9� REMOVE EXIST. CONDUIT. REVIEWED FOR CODE COMPLIANCE APPROVED SEP 24 2019 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA AUG 3 0 206 PERMIT CENTER 0 O LL J " W m J � O O Q � 0.0 W � W � s E LU ��m� cc NY 0 r z F Z) Ln z 0 V E V O J J u N G Q 00 a U rn o Q N_ E 'y ai o a Q U 0 'G, tncLL!3 V) z 3 c o000 wv° 2� �Q N VU mto Ln z Utz tNDA- qzt z 00 G( d' a `n J > 0 -nO 00 or, co z m rn In=O 0 J Lu `� Q LIJ cn u � a = t M �CL W F— z ISSUED/REVISED DATE PERMIT SUBMITTAL 8/22/19 PERMIT SET 8/28/19 COLO 4 DEMOLITION FLOOR PLAN COPYRIGHT © CASCADE MISSION CRITICAL, LLC 2019 1 3 4 5 6 F 0 0 11 WA z 9 11 E C C V 01 Ct COLO 4 144 i I I I I i i i i i i i i i i I I I I ------------- ---------- i-------------------�� -- - - - -- - - -- - - - - - -------rt--------,----------------,--------rt--------,----------------,--------,-------,--------,------ --t-� -----------------� — ----- ------------ I I I I I I I I I I I I I 2 IT, p 1 i I �_,�7 P. I I I i 2 P. I 2 T P. I I I I i I I 3 I I i I i I { )RRIDOR CORRID( 140 149 I j1 1 T P. I j I j 1 P. I I 1 1 P. ,1 ITyp. I 1 I I I — 1 — — — — — — — a— — — — --------- I — — —U#— — — — I I j I I I I I I i I I 1 j I i I i I i 1 i I i I I I j I j i 1 i i I j 3 j I j i I i I I I i I i 2 P. 2 P. j 2 P. TITR i j 2 P i i i I I I I I I I I I j j j j j I I I I I I I I I j j I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I N COLO 3: SCALE: 1/8" = V-0" DEMOLITION CEILING PLAN DEMOLITION NOTES 1. CEILING IN COLO 4 AND OTHER AREAS HAS BEEN PARTIALLY REMOVED. CONTRACTOR SHALL FIELD VERIFY ALL QUANTITIES OF MATERIALS AND SYSTEMS TO BE REMOVED. 2. UNLESS OTHERWISE NOTED, REMOVE COMPLETE ASSEMBLIES TO LEAVE THE AREA IN A CLEAN CONDITION. 3. PATCH AND REPAIR ANY EXISTING MATERIALS OR ASSEMBLIES TO REMAIN IF DAMAGED DURING DEMOLITION. 4. COORDINATE ALL DEMOLITION ACTIVITIES FOR ALL DISCIPLINES AS SHOWN ON OTHER DRAWINGS OR CALLED FOR IN OTHE SPECIFICATION SECTIONS. 5. REMOVE AND RETAIN FOR RE -INSTALLATION ALL CEILING MOUNTED SMOKE DETECTORS, SPEAKERS, & FIRE ALARM ANNUNCIATION DEVICES. 6. REMOVE ALL EXISTING SUSPENDED CEILING GRID SUPPORT WIRES AND BRACES IN AREAS WHERE CEILING IS BEING REMOVED. 7. REMOVE ALL WALL MOUNTED METAL CHANNEL SUPPORT FRAMING. 8. REMOVE ALL EXIST. HSSD SENSOR PIPING BACK TO 12" FROM EXIST. SENSOR AND CONTROL PANEL. CUT PIPE WITH SQUARE, CLEAN CUT TO ALLOW FOR INSTALLATION OF NEW PIPING. PROVIDE TEMPORARY COVER AT END OF CUT SENSOR PIPING. 9. VERIFY THAT EXISTING UTILITIES SERVING THE SPACE HAVE BEEN DISCONNECTED AND CAPPED BEFORE STARTING DEMOLITION ACTIVITIES. COORDINATE WITH THE OWNER ON ALL SHUTOFFS OF UTILITY POWER IN ANYAREA PRIOR TO SHUTTING OFF ANY UTILITY. 10. VERIFY THAT ANY HAZARDOUS MATERIALS HAVE BEEN REMEDIATED BEFORE PROCEEDING WITH DEMOLITION OPERATIONS. 11. PROVIDE TEMPORARY BARRICADES AND OTHER PROTECTION AS REQUIRED TO PREVENT INJURY TO PEOPLE. TEMPORARY BARRICADES SHALL REMAIN IN PLACE AS LONG AS POTENTIALLY HAZARDOUS CONDITIONS REMAIN. 12. DEMOLISH AND REMOVE EXISTING CONSTRUCTION ONLY TO THE EXTENT REQUIRED BY NEW CONSTRUCTION AND AS INDICATED. USE METHODS TO COMPLETE THE WORK WITHIN LIMITATIONS OF GOVERNING REGULATIONS AND OWNER'S WORK RULES. 13. COORDINATE WITH THE OWNER FOR CONDUCT OF DEMOLITION ACTIVITIES TO MINIMIZE DISRUPTION TO EXISTING TENANTS AND USERS OF THE BUILDING. DO NOT CONDUCTANY FLAME CUTTING, WELDING, GRINDING OR OTHER OPERATION THAT COULD POTENTIALLY TRIGGER THE FIRE ALARM SYSTEM OR INCIPIENT SMOKE DETECTION SYSTEM WITH SPECIFIC WRITTEN APPROVAL FROM THE OWNER. COORDINATE WITH THE OWNER IF FIRE ALARM SYSTEMS ARE REQUIRED TO BE DISABLED OR PLACED IN TEST MODE IN ANY SPACE. DEMOLITION KEY O REMOVE EXISTING ACT PANELS OR GRID MEMBERS THAT ARE DAMAGED. O REMOVE EXISTING 2' X 4' TROFFER LIGHTING FIXTURES. 3�J EXISTING ACT GRID SUPPORT SYSTEM TO REMAIN, TYP. 0 O LL U _1 J W m J ~ o Q � W N dW Hoo E m0 o W m -0 cc fu ~ Q :03 O A105 H z H J REVIEWED FOR CODE COMPLIANCE APPROVED SEP 24 2019 City of Tukwila BUILDING DIVISION z ;?z E U o U J m J � J C U O Q N_ E E CE.o my v � � u Oo"'� �w3 Nc 3 m a eo 0 WU ;N 00 UU MD Q a ON o `j UQ ZDn; 0r O z_ zo o}t mzm I. — WV) QWO ci wW0 LU in U Q (D CL W F_ z (Ij� _r_ Ob N � c-I cy, 4� Q O N P �'S d' Y m ISSUED/REVISED _ DATE_ PERMIT SUBMITTAL 8/22/19 RECEIVED CITY OF TUKWILA AUG 3 0 2019 PERMIT SET PERMIT CENTER 8/28119 1 3 on 7 F; 0 WE m EVA 9 CORRID A OPS/GUST. WORK AREA I C i n0 I I I I I j GEN. OFFICE 144 i i j I 1 i i I I I MAINTENANCE SHOP 173 COLO 6 ' 166 �i 'Y I FYI CORRIDOR 150 I I ! SYSTEM SUPPORT ROOM 11 155A I I ! EC ! EC 164 I i I I I I I I I I i SPRINKLER I I 151 i I `'' 1�j ; i i i i i -------- --------------------------;------------------------------------------------------;---------------------------;------------------------- -;---------------------------; i------------------ i i i i i i i ------t------1--------r--------rt-----r------i-r------�-ri-----� -r-------T-------r-t----,-1------ i 1------ ---------r----- -r- ---- ---- 1`-r--r------�f -r--I----1-T---___— T-__ -----''-J'I----'�-J-----�'--1------"a--1-�'-----`-1-------`-1-------'—i'a-----'--�------�--1------''-J-�'----�-J------''-J------'�-J--I-----'-J-------`-•'1---- --'--L -'�'---�-J-------'-1-------�'------�'-1------'`-J--- I I I I I I I ----- i -1 --- - T------ - -------- -r� -----� -r------------j--T------i r------i------—�-------1-----------------r----- --r- --- r--------r--------r-- -----T--------r--- , ' 1 I 1 , i 1 , 1 1 1 �_1______i-J_i ____a._J ______i_J___,___i_J__' ___.a_J-_____.a-J_ -___ _i____ ------ v.------- --_'-------- TYP. TYP. 3 -------li-----, ------ ------ -rt----r-------r------ -r-1----- -r-------r--------t-t-----1-------1-------r-I----- ----- ', i i i i 1 1 1 , i-r----- I -r---- I -r t----I -r -r------- -r--I----f T ------ 1 r--- ' , 1 � 1 1 1 _J_____y_J______y_J_l..____i.1______�1____.-__­L______a._J.------ i._J_1____a_J------ .a_J______s_ 1 TYP. 2 TYP. I TYP.! 2 1 TYP. ! -..---- 7^----- ------"-----� -r------r -T------j T-T----j t------------- ��1- ---- j-I------ I-r----- -r -''- --� -r--- --j- -r------j- -r--I !----j--T------j T--- i--_ _____ a._L___-_____--_i_J___ I I I I I I -- ti--------1--------r------ -rt----- -r------ -r------ -r------~IIO------ t----- r------r------r-t----i------ - - - T--- 1 44 1 I I I I I I _'--- t t------ i -r ---- -r------- -r------i -r^-------r--------T-------r-^-----t--------1---------i--•------t-------I--r--------r-T-----^r--- -- r--- I I I ; i l ; i ; , ; i l i i l ' ' ' ' 1 ' � � � 1 1 I 1 1 1 , 1, 1 , I , 1 1 1 I , I 1 1 -� I- -, .._J_r .�_J___________.a-J__j____y_J______a_J.._____iI__7____i1._____ `J._____ ._L__' ___�_..7._-____i._J___ i i i i i i i -----,-/i----- t------ -;- ---- -� i - -- ;FIBLfV-�;E11M -f -� --- -� -�------�-T-------f----� 1-- ---� -1--- -- 1 t--I---- I—,-------r----- -r--F----� -r------,--------� r--I----i -T------i r--- 1 1 1 f 1 , 1 1 1 , 1 1 1 1 .-_-_-.-_- _-_-_{__-1-_-_-1- y_. ./._-_-_-i-_I-.-_y._-{_ _ y._J_-_ i-_I-_-._-_y._J--_-_-i-__I_-_-_-{-_1-_-_J_ ,-_t,..._.L y-J_-_-_-.,.__ ------ I-,-_!__-_-_y_-4-_ - 1�-- , 1 , --- , 1 , ----- 1 , i_J____-- _J__I___...a_J______s_ L_ ____`1. ib i i i i 189 iF T 142 ________ ________________________ _________________ { I , ----' -1 ; 1 ; ' i 1 ; 1------ ; - I -----;------ -r- 3 , , 1 ___J_ s_J______.a_J__ ___ ______s..-L___ ------- - ! 1 TYP. - 2 TYP. ---- ?---- ----- TYP. 2y J 1 STOR_ B- --- �- '- i o� i�� ..,..... I , r------� -r------� r-I--- -T- t 1-t-------- - 1 , i 1------ i r-I- EXIST. CLG. P. H S ! 1 ; ' ; 1 I ; i ' i ; i ; TO REMAIN j TO REMAIN I 3 R O 1 1 1 ' ' -- 1----- , 1 ' ' , , , , , ___.L_____�L______�._L______�_._t, _I___- LI __ _J______.a_ _____�._J ___ _�._J______------- FIBER TERM. ! 3 fYp ! 3 p,.p TYP. ! — EXIST. CLG. EXIST. CLG. /+� (��C p I STOR, A 3 TO REMAIN j TO REMAIN -----r -r---Vt_—"ET-A-� -r-'-----� T---- -� t-- ------t--'----� --I - 1 , -r-- -- 1--r145A --�----7--�-- 1 1 1 1 1 ( V' I I N COLO 4: DEMOLITION CEILING PLAN SCALE: 1/8" = V-0" DEMOLITION NOTES 1. EXISTING CEILING HAS BEEN PARTIALLY DEMOLISHED. CONTRACTOR SHALL FIELD VERIFYALL QUANTITIES OF MATERIALS AND SYSTEMS TO BE REMOVED. 2. REFER TO SPECIFICATIONS FOR DETAILED REQUIREMENTS FOR SELECTIVE DEMOLITION. 3. UNLESS NOTED OTHERWISE, REMOVE COMPLETE ASSEMBLIES TO LEAVE THE AREA IN A CLEAN CONDITION. 4. PATH AND REPAIR ANY EXISTING MATERIALS OR ASSEMBLIES TO REMAIN IF DAMAGED DURING DEMOLITION. 5. COORDINATE ALL DEMOLITION ACTIVITIES FOR ALL TRADES AS SHOWN ON OTHER DRAWINGS OR CALLED FOR IN OTHER SPECIFICATION SECTIONS. 6. REMOVE AND RETAIN FOR RE -INSTALLATION ALL CEILING MOUNTED SMOKE DETECTORS, SPEAKERS, & FIRE ALARM ANNUNCIATION DEVICES. 7. REMOVE ALL EXISTING SUSPENDED CEILING GRID SUPPORT WIRES AND BRACES IN AREAS WHERE CEILING IS BEING REMOVED. 8. REMOVE ALL EXIST. HSSD SENSOR PIPING BACK TO 12" FROM EXIST. SENSOR AND CONTROL PANEL. CUT PIPE WITH SQUARE, CLEAN CUT TO ALLOW FOR INSTALLATION OF NEW PIPING. PROVIDE TEMPORARY COVER AT END OF CUT SENSOR PIPING. COLO 3 TO REMAIN COLO 3 143 DEMOLITION KEY O REMOVE EXISTING CEILING SUPPORT GRID, WALL ANGELS, AND MISC. TRIM. REMOVE ANY REMAINING ACOUSTIC CEILING PANELS IN THE COLO 4 AREA. 2� REMOVE EXISTING CABLE TRAY SUPPORT FRAMES IN THE ENTIRE COLO 4 AREA. O REMOVE EXISTING 2'X4' AND 2'X2' TROFFER LIGHITNG FIXTURES. WE W REVIEWED FOR CODE COMPLIANCE' APPROVED SEP 24 2019 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA AUG 3 0 2019 PERMIT CENTER 0 0 J CI' � W cc J ~ o Q @ W V 1000 w -.-. E h— coma) ° Y o 1 Lu � ^ m z W �m ~ 8 3 O z~a 3 F- z H J D v) z O U E U J " J U In 4 U 0,0 0.2 1 Q N_ e, �: E U 1 N-0 O *fQ u OO"- 3 v) z 3 h a 00 O WU jN GI`m¢v Q N �N Uv m1.o Q°O0 UQ LDri 4 d" O z z zo �o J}c � O �� C) mzM Xj0 V�0}Q > J w LIJ e-i 0 v)i LU V? U cn �a m� W I— z ISSUED/REVISED DATE PERMIT SUBMITTAL 8/22119 PERMIT SET 8/28/19 COPYRIGHT © CASCADE MISSION CRITICAL, LLC 2019 COLO 4 DEMOLITION CEILING PLAN "0 v� 6 1 2 3 4 5 6 7 8 9 10 11 12 z X 11 :0 x c .1 �i N COLO 3: FLOOR PLAN SCALE: 1/8" = 1'-0" FLOOR PLAN NOTES OEXISTING CRAH UNIT FRAME TO REMAIN. PROVIDE TEMPORARY SAFETY BARRIERS AROUND OPENING. ,2) RAISED FLOOR REPLACEMENT -GENERAL NOTE: REPLACE ALL RAISED FLOOR TILES REMOVED DURING DEMOLITION WITH TILES FROM OWNER STOCK. NOTALLTILE REPLACEMENTSARE SHOWN ON PLAN. CONTRACTOR TO FIELD VERIFY QUANTITY OF TILES TO REPLACE. FILL IN EXISTING OPENING WITH NEW STRINGERS, PEDESTALS, AND PANELS AS REQUIRED. 140 MODIRY EXISTING OPENING TO ACCOMMODATE NEW EQUIP. STAND WITH NEW STRINGERS, PEDESTALS AND PANELS AS REQUIRED. PROVIDE NEW STRINGERS, PEDESTALS AND PANELS AS REQUIRED FOR NEW EQUIP. LOCATION. O REINSTALL NEW EMERGENCY KIOSK AND RECONNECTALL DEVICES. G11 G11 U 0 U y m u Ln ,-I 00 U U (n < c VE U (U C) zU .t) 03 0 r3 Lq z 3: 3: :p '.D . a 00 Lj.j < U ko c� m W ('r) < '-"0" uc) koE ULAN b- 05 z 0z r-4 zo C) Lr) —j > 00 06 -15 1.0 0 r-, r-1 ca :;;p M iz-4 00 LLJ U1 r-i _c < CC < 0 U.J 0 v) ca LLJ !;� m LIJ V)u m < ;* —r m 00— cr— LLJ z ISSUED/REVISED DATE PERMIT SUBMITTAL 8/22/19 REVIEWED REVIEWED FOR - CODE COMPLIANCE APPROVED SEP 24 2019 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA PERMIT SET AUG 3 0 2019 8/28/19 PERMIT CENTER COLD FLOOR PLAN ZS( A-1 COPYRIGHT @ CASCADE MISSION CRITICAL, LLC 2019 1 2 3 4 5 6 7 8 9 10 11 12 z 9 F1 5 9 u C 0 N COLO 4: FLOOR PLAN SCALE: 1/8" = V-0" FLOOR PLAN NOTES OEXISTING CRAH UNIT FRAME TO REMAIN. PROVIDE TEMPORARY SAFETY BARRIERS AROUND OPENING. (NOT USED THIS SHEET). ORAISED FLOOR REPLACEMENT -GENERAL NOTE: REPLACE ALL RAISED FLOOR TILES REMOVED DURING DEMOLITION WITH TILES FROM OWNER STOCK. NOT ALL TILE REPLACEMENTS ARE SHOWN ON PLAN. CONTRACTOR TO FIELD VERIFY QUANTITY OF TILES TO REPLACE. 3OFILL IN EXISTING OPENING WITH NEW STRINGERS, PEDESTALS, AND PANELS AS REQUIRED. JMODIFIY EXISTING OPENING TO ACCOMMODATE NEW EQUIP. STAND WITH NEW STRINGERS, PEDESTALS AND PANELS AS REQUIRED. (NOT USED THIS SHEET). 5OPROVIDE NEW STRINGERS, PEDESTALS AND PANELS AS REQUIRED FOR NEW EQUIP. LOCATION. 8� REINSTALL NEW EMERGENCY KIOSK AND RECONNECT ALL DEVICES. REVIEWED FOR CODE COMPLIANCE auoonvcn 0 0 LL J a' V � W m J — O Q � W � v00 HS oio omo E corn o Q 'ado W � ��^� 0 0 z NFo 3 z H D N z 0 U E U s J J u L.n F Q 00 U V O) ° d 'E H,� a U� au0 v O � u a a, w 0 O cn u 3 v}cw3 z 3 :300 LLIU jN Q V U m ID 00 o Uo° Co'a d. O Z z z0 vO OQd- J>c 50 o o� mom V�0a � J Liuuj Q Lo w t/) U 3 mrn re a W z ISSUED/REVISED DATE PERMIT SUBMITTAL 8/22/19 COPYRIGHT © CASCADE MISSION CRITICAL, LLC 2019 1 2 3 4 5 6 7 8 9 11 11 12 a G 19 CC E IIIIIIIIIIIIIIA] C 03 (D i I I I I I I I i I I I I I I I i I I I I I I I - - - - - - - - - - - - - - - - - - - - - - -- - - - - - -- - - - - - - - - ' I - - - -- - - -- - - - - -I - -- - - - - -- - -- - - - -- - - - - - - - - - - - - - - - - - - - I --- ------------------- I -i----------------- - --- ------H�ua I I h I i I i I 77 5I 1 2 I I I I I j I I 1 I I I i i i i i F ACT1 i I i i i I i 1 1 I 1 C 1 I i 1 G 1 I i 1 C 1 F---- I LJ J i I I i I I 1L I I I--- ----- I i i - - i - - i i --I 3 3L, 3 --- J I i I I I j I I I I C5 I j 501 i tRRIDOR j j i i CORRID+ 148 148 i i i i i i i i i i i i i i i i i i i i i i i i 2 i i i i i i I I I i i i i i i I I i I i I I I I I I 1 I I 1 f I I I I I I I I I I I I I I I I I I I I I I I I I I N COLO 3: REFLECTED CEILING PLAN SCALE: 1/8" = V-0" CEILING NOTES CEILING KEY 1. INSTALL NEW ACT CEILING PANELS IN ACCORDANCE WITH MANUFACTURER'S O INSTALL NEW ACT CEILING PANELS FROM OWNER'S STOCK TO REPLACE INSTRUCTIONS. DAMAGED PANELS REMOVED OR AS REQUIRED AT NEW WORK. 3. REINSTALL EXIST. SMOKE DETECTORS REMOVED DURING DEMOLITION. O NEW 2' X 4' TROFFER LIGHT FIXTURE PER ELEC. TYPICAL FOR ENTIRE RECONNECT TO FIRE ALARM SYSTEM, MAINTAINING SYSTEM SPACE. ADDRESSING AND FUNCTIONALITY. O NEW HVAC RETURN AIR DUCT EXTENSION TO BOTTOM OF ACT SUPPORT 4. ALL LIGHT FIXTURES MUST BE MECHANICALLY ATTACHED TO THE GRID. CEILING SUPPORT GRID. 5. REFER TO ELECTRICAL FOR FIXTURE TYPES, EGRESS LIGHTING LAYOUT AND PHOTOMETRICS. 0 REVIEWED FOR CODE COMPLIANCE APPROVED SEP 24 2019 City of Tukwila BUILDING DIVISION L O LL U c J J W m J � O dN w F- 00 v� v Lo �ago omo E mrn� o W F- 0 3 oN O z m n wr o Lu Z co o� E U o J - 1 u Ln d oo O U p1 O U y N @ N O N Ocu O N u LL y � W LU o v ¢� d � 'N,b Uv m Q o, o UQ wn: O z z z�N v O" �Qd' to Ll O co rl mzM � o ��0 - d � WHJ O UJ t) tt �cn V 3 W z ISSUEDIREVISED DATE PERMIT SUBMITTAL 8/22/19 COPYRIGHT (c) CASCADE MISSION CRITICAL, LLC 2019 I 116— F Cl -4 OF WI F97j C MEMO IIIIIIIIII10A 3 4 5 6 7 8 9 10 �� ® ® o o ® ® ® o 0 SYSTEM SQPPORT ROOM IV COLO 4: REFLECTED CEILING PLAN SCALE: 1/8" = V-0" CEILING NOTES CEILING KEY 1. INSTALL NEW ACT CEILING SYSTEM IN ACCORDANCE WITH MANUFACTURER'S INSTALL NEW ACT CEILING GRID AND PANELS TO MATCH OWNER'S STOCK. INSTRUCTIONS. NSTALL AT HEIGHT TO MATCH EXISTING ACT IN COLO 3. 2. PROVIDE SEISMIC BRACING FOR CEILING FOR SEISMIC DESIGN CATEGORY I'D" O NEW 2'X 4'TROFFER LIGHT FIXTURE PER ELEC. TYPICAL FOR ENTIRE IN ACCORDANCE WITH IBC SECTION 808, ASTM C 635 & ASTM C636. SPACE. 3. REINSTALL EXIST. SMOKE DETECTORS REMOVED DURING DEMOLITION. rz-) NEW HVAC RETURN AIR DUCT EXTENSION TO BOTTOM OF ACT SUPPORT RECONNECT TO FIRE ALARM SYSTEM, MAINTAINING SYSTEM GRID. ADDRESSING AND FUNCTIONALITY. 4. ALL LIGHT FIXTURES MUST BE MECHANICALLY ATTACHED TO THE CEILING SUPPORT GRID, 5. REFER TO ELECTRICAL FOR FIXTURE TYPES, EGRESS LIGHTING LAYOUT AND PHOTOMETRICS. 11 12 REVIEWED FOR - CODE COMPLIANCE APPROVED SEP 24 2019 City of Tukwila BUILDING DIVISION E 0 U Ln --4 00 r cn.o -t3l U IU z MU (5 1 U V) z 3; 000 c 0 LLI -c a) UU MN MtD U 0 Iqt b 77 (D z z 0 00 > m 0co �o 6 vj CDZM 00 c~nLU U1 0 < 4� < Lu LLJ 0 0 V) LU U ry) <Ln —r cn CL Uj I-- z ISSUED REVISED DATE PERMIT SUBMITTAL 8/22/19 COPYRIGHT @ CASCADE MISSION CRITICAL, LLC; 2019 1 2 3 4 5 6 7 8 9 10 11 12 H 0 0 EXIST. ROOF I STRUCTURE I G i I i T— COMPRESSION POSTS D.C. . @ 12'-0" OCBOTH WAYS CEILING BRACING WIRES i 4 WIRES SPLAYED AT 45 DEG. . IN 4 DIRECTIONS, 12'-0" O.0 ren Inln QI loono-r AT COMPRESSION POST LOCATIONS A EXIST. ACT < CEILING GRID TO REMAIN NEW ACT CEILING - PANELS IN MODIFIED CEILING GRID AS NOTED ON PLANS 10 1 C i 0 WIRES (TYP.) i i r% ., �.n,<, �P5 r„,x: � uv a,h a Ss .., r- _rv,.,. r_. ... 3 t. „.,r..zn sk :r , •:u a:... P 4✓.. wi. . ., e Xa o. I I t ..W '3 -:.;. c. ea n, .� ... ? .b; t:.. L A-Y:P. ;re 'r vt .. P. #I. }. I I i 11 I I I I I I I I I C3 501 A501 \ ILI IR NEW 2'X4' ACT CEILING RETURN NE E9 EXIST. WALL SYSTEM OPENING PIER MECH. A501 A501 i i SEISMIC JOINT RETURN AIR DUCT PER MECH. o NEW 2'X2' RAISED FLOOR NEW CRAB UNIT NEW PDU `- PANELS INSTALLED IN EXIST. PER MECH, PER ELEC. j STRINGER AND SUPPORT I SYSTEM AS NOTED ON PLANS EQUIP. E7 Bpp,,SE A501 TYP. RAISED i G5 G7 G1 FLOOR G5 G7 A501 A501 A501 I G9 A501 i I I I I I I I � I I I I I I I I N K tZ rx,. �.,i r. L _j\ FXIRT RAIRFf] FI nnR - - ---- I- -- - - - �.,...,-.- .-,..,..-.. �..,.,._ .... �... ,.. STRUCTURE rvcvv OIZICIIvn%� EXIST. CONC. STAND FLOOR SLAB COLO 4: CROSS SECTION D3 SCALE: 1/4" = V-0" r"I[UVIUGHUUI 0.. rCLJCJ IHL IVCVV StiJM1U LUU1N. —' AT OPENINGS AS REQUIRED (TYP.) WILL NOT BE USED AS A SUPPLY STAND AIR PLENUM. WILL ONLY BE USED FOR DISTRIBUTION OF POWER AND COMMUNICATIONS. ROOM FINISH SCHEDULE ROOM NO. ROOM NAME FLOOR BASE WALLS CEILING 141 EC RF1 RB1 P1 EXIST. 142 EC RF1 RB1 P1 EXIST. 143 COLO 3 RF1 RBI P1 ACT1 144 COLO 4 RF1 RB1 P1 ACT1 14SA STORAGE RF1 RB1 P1 ACT1 14SB STORAGEB RF1 RBI P1 ACT1 147A FIBER TERMINATION CLOSET A RF1 RB1 P1 ACT1 147E FIBER TERMINATION CLOSET RF1 RB1 P1 ACT1 148 OPS/CUSTOMER WORK AREA RF1 RB1 P1 ACT1 188 EC RF2 R62 P2 EXIST. 189 EC RF3 RB3 P3 EXIST. FINISH ATE IALS SCHEDULE NO. TYPE MFG. DESCRIPTION COMMENTS P1 PAINT SHERWIN WILLIAMS SW7100: ARCADE WHITE ACT1 ACOUSTIC CEILING TILE ARMSTRONG ULTIMA ITEM NO 1938: WHITE RB1 RESILIENT BASE ROPPE 700 SERIES: 194 BURNT UMBER, 4" RF1 RAISED FLOORING EXIST. EXISTING TILE FROM OWNER'S STOCK OR AS SALVAGED FROM EXISTING SPACE. CONDITION AT TIGHT WALL - REFER TO DETAIL C1/A501 FOR CONDITION AT FLOATING WALL G11 REVIEWED FOR CODE COMPLIANCE APPROVED SEP 24 2019 City of Tukwila BUILDING DIVISION L O O LL U c J � U.j m J (if �o Qm W C N ZW1000 LU 56-8md E � mm- o LU ��Mla F o6 m LUo'� z C) 3 0 "_19n 3 i r L W � o <�� 0 E U ° J • J � Ln Q 0000 U C cn.0 U L Q N r"- C 1j •� c•S 2-0 N N UC, v N 0 O u t/)c LL!3 z 3 v LU U N �N M� Q a oQ Utz Lon. d' O ;7 z_0 o p < qr LI? J>0 � �O o� mGm 4 rn Ln = 0 Q J 0 W `� O V) m LLJ ILLJ ��U CL W z ISSUED/REVISED DATE PERMIT SUBMITTAL 8/22/19 COPYRIGHT @ CASCADE MISSION CRITICAL, LLC 2019 I 12 I 11 E It, C A Ul 19 m 9 me: il 2" X 3" X 1/8" ALUM. EQUIP PER 2" X 3" X 0.125 ALUM. — 0 1/2 — 0 1/2 WALL PER PLAN L 0 EQUIP. PER CLOSURE TRIM PLAN CLOSURE TRIM 6" EQUIP. PER 16" - RAISED FLOOR 0 1/2 MIN. PLAN PAN HEAD SCREW N PAN HEAD SCREW EQUIP. PER LUM. PLAN MIN. 2" X 3" X 0.125 A CLOSURE TRIM — 2" X 3" X 0.125 A PLAN CLOSURE TRIM ALUM. PANELS PER PLAN & SPEC RA ISED FLOOR PANEL PER PLAN & SPEC. 0 1 1-01, Oc @ V-0" OC MIN, PAN HEAD SCREW PAN HEAD SCREW 'QA_5_01j RAISED FLOOR I" RASIED FLOOR @ 1'-0" Oc @ 1'-0" 0C PANEL PAN PANEL RAISED FLOOR ALUM. PL. 0.125" 77— PANEL — ---- - J®RA STRINGER STRINGER STRINGER STRINGER STRINGER STRINGER S STRINGER WALL PER PLAN PEDESTAL STRINGER WALL PER PLAN PEDESTAL z STRINGER PEDESTAL HEAD z P < 7— z EQUIP. BASE PEDESTAL :5 E PEDESTAL PH HEAD z HEAD EQUIP. BASE z HEAD PEDESTAL HEAD _j IL HEAD 11. PROVIDE ADD'L. STRINGER BOLTS W W W STRINGER BOLTS 1. I? PEDESTAL W III if PEDESTALS AS W REQ'D FOR Q_ W '7 STRINGER BOLTS PER SPEC. . PERIMETER PEDESTAL (L PER SPEC. a. TO SUPPORT PEDESTAL PEDESTAL 1: (9 PEDESTAL :c EQUIP. BASE CLOSURE PL. BASE PEDESTAL FIELD PEDESTAL BASE BASE W BASE ui PEDESTAL BASE PEDESTAL W W PEDESTAL EQUIP. BASE m: SLAB SLAB BASE ANCHOR BOLTS PER STRUCT. BASE ANCHOR BOLTS ANCHOR BOLTS ANCHOR BOLTS PER STRUCT. PER STRUCT. ANCHOR BOLTS PER STRUCT. SLAB SLAB ANCHOR BOLTS PER STRUCT. J PER STRUCT. SLAB 2 SLAB REFER TO DETAIL X/XXXX WHERE EDGE OF REFER TO DETAIL G5/A501 WHERE EDGE OF REFER TO DETAIL G1 lIA501 WHERE EDGE OF EQUIPMENT BASE OCCURS AT LEAST REFER TO DETAIL G9/A501 WHERE EDGE OF EQUIPMENT BASE OCCURS LESS THAN 6" PROVIDE ADDITIONAL PERIMETER PEDESTALS EQUIPMENT BASE OCCURS AT MID -SPAN OFRAISEPASTRN6" EQUIPMENT BASE OCCURS AT EDGE OF FROM FWALFROM FACLTYP. RAISED FLOOR YDERTRAISEDI TP. FLOOR PERIMETER TYP. RAISED FLOOR @ EQUIPMENT BASE TYP. RAISED FLOOR @ EQUIPMENT BASE TYP. RAISED FLOOR BEHIND EQUIP. BASE TYP. RAISED FLOOR G11 BEHIND EQUIP. BASE PEDESTAL & PANELS G3(a)_ 1 1/2" = 1 RF-02 G5 G7 SCALE: 1 1/2" = 1'- 0" RF-04 G9 SCALE: 1 1/2" = V-0" RF-05 SCALE: 1 1/2" = V-0" RF-06 SCALE: 1 1/2" = V-0" RF-03 SCALE: 1 1/2"= V-0" RF-01 SCALE: PAN HEAD SCREW @ 1'-0" Oc RAISED FLOOR PLAN WALL OR OPENING BEYOND RAISED FLOOR PANELS PER PLAN Wl' ROTATE BASE AS SLAB REINF. REQ'D TO AVOID STEEL REINF. STEEL COMPRESSION POST VERT. HANGER WIRE ADJ. TO POST NOTES: AT SINGLE JOINT LOCATION, 4-WAY SEISMIC PROVIDE JOINT MOVEMENT SEPARATION JOINT IN ONE DIRECTION ONLY. -cTj WALL PER PLAN PANELS PER & SPEC &S XX"SADDLE & SPEC THRESHOLD EQUIP. FRAME BRACINGBRACING WIRES AT ADJACENT SEISMIC JOINT CLIP LOCATIONS, PROVIDE JOINT ABOVE __j WIRES MOVEMENT IN BOTH FIELD CUT Q P. L,- 2 o-1 MAIN MAIN A DIRECTIONS. TEE P N 2" X 3" X 0.125 ALUM. CLOSURE TRIM TEE STRINGER STRINGER STRINGER 09 Z ALUM. PL. 0.125" 7 0 m z EQUIP. FRAME FRA E M PEDESTAL LOWERED PEDESTAL ED To Q. ALLOW FOR HEAD FOR HE PEDESTAL HEAD ------- G11_U SAFETY WARNING F R ST 'J7 FLOOR W RAISED FLOOR STRINGER BOLTS TO CONTINUE R CONTINUE RINGER BOLTS ELEV DATUM ELEV DATUM IN RED TEXT A501 2'-0" OC MIN. OVER FRAME PER SPEC. PER SPEC. BELOW WALL B 1/2" DIA. X 3 F, 7 0 PEDESTAL PEDESTAL FLOOR PER PEDESTAL PLAN A.B. CEILING PANELS CEILING FACE TEE BASE PEDESTAL EQUIP FRAME PER SCHED. PER SCHED. SLEEVE ADD'L PEDESTAL zz" AND HEAD ASSEM. ANCHOR BOLTS SLAB ANCHOR BOLTS PER STRUCT. BASE BASE 2" AS REQ'D. 2'-0" PER STRUCT. CROSS TEE MAX. -TYP. OC MIN. CONC. SLAB MIN. TYP. RAISED PLAN VIEW FLOOR SLAB CONTRACTOR SHALL DETERMINE LOCATIONS OF ALL REINFORCING STEEL IN SLAB AT EQUIP. FRAME NOTE: INSTALL BRACING WIRES @ 45 DEG. FROM APPLICABLE WHERE DISTANCE BEHIND EQUIP. IS LESS THAN 6" LOCATIONS PRIOR TO DRILLING FOR ANCHOR BOLTS. PLANE OF CEILING TO STRUCTURE IN FOUR DIRECTIONS. TYP. RAISED FLOOR BEHIND EQUIP. BASE TYP. RAISED FLOOR E3 C FUT. EQUIP. LOCATION TYP. RAISED FLOOR E5 FLOOR TRANSITION (,@- WALL E7 EQUIP. BASE ANCHORAGE ACT COMPRESSION E9 POST & BRACING E11 ACT SEISMIC JOINT SCALE: 1 1/2" = 1'-0"1'-0"-0" RF-07 SCALE: 1 1/2" = -0" RF-08 SCALE: 1 1/2" = VRF-1 0 -0" SCALE: 1 1/2" V- 0" SCALE: 6" = V-0" SCALE: 6" = 1'-0" ACSJ-01 8" MAX. NTS 8"MAX. NTS 3/4" MIN, CEILING PANEL HANGER WIRE 10 DEG +/-10 DEG i PER SCHED. k PERIMETER WALL PER 6 HANGER WIRE lt PERIMETER WALL PER 6 HANGER WIRE 1/8" SELF SUPPORT E ADHESIVFOAM PLAN GRID PLAN TAPE AN ELEV. ELEV. ELEV. DATUM 0 DATUM& — MAIN TEE OR MAIN TEE OR NOTE: LOCATION OF CROSS TEE CROSS TEE 1 1/2" X 1 1/2" DUCT TO GRID CEILING PANEL CEILING PANEL WHITE SHT. TEES VARIES METAL TRIM PER SCHED. PER SCHED. RIA DUCT ANGLE -FASTEN EXTENSION WALLATTACHMENT WALLATTACHMENT W1 WHITE SCREWS @ 1'-0" 0C CLIP 2" CLIP WALL ANGLE WALL ANGLE ACT WALL ANGLE ACT WALL ANGLE ACT AT RETURN AIR SEISMIC CATEGORY D-F C3 SEISMIC CATEGORY D-F C5 DUCT EXTENSION SCALE: 6" = V-0" FLOATING WALL SCALE: 6" = V-0" TIGHT WALL SCALE: 6" = V-0" ACWAS-0 ACWAS-02 REVIEWED5 FOR CODE COMPLIANCE APPROVED SEP 24 2019 City of Tukwila I BUILDING DIVISION RECEIVED CITY OF TUKWILA AUG 3 0 2019 PERMIT CENTER q. 04Z9 & COPYRIGHT Uc CASCADE MISSION CRITICAL, LU, 2019 F_ z z 0 U o z LL 0 LL LS 0 0 Uj E 0 U y i m _j u In co 'c (n.0 U (D v 3 Z' V) z 0 3 V) U' 3 V); z 3: �g a W a 00 U.j rq Ur� d iD V) rn tp 00 U Q W M 1�t c; z (D z z 0 0 r) j > CL :) 0 O2 k000 Co ;:;p M ULJ0rNi Ul "_j 4� _j 0 Uj Uj 0 0) co LU< U m m :f m (D CL Uj 1l__ z ISSUED/REVISED DATE PERMIT SUBMITTAL 8/22/19 PERMIT SET 8/28/19 DETAILS A-50