HomeMy WebLinkAboutPermit M19-0043 - TRAPPER'S SUSHI - COMMERCIAL GREASE HOOD, MAKE-UP AIR AND GREASE DUCTS ETCTRAPPER'S SUSHI 168 SOUTHCENTER MALL M19-0043 Parcel No: Address: City of Tukwila Department mfCommunity De ent 6]0OSouthcenmerBoulevard, Suite #1VO Tukwila, Washington 98lB8 Phone:Z06-431'367V Inspection Request Line: 206'43D'93S0 Web site; http://www.TukwilaWA.Rov MECHANICAL PERMIT 9202470010 Permit Number: K419-0043 Project Name: TRAPPER'S SUSHI Issue Date: 4/29/2019 Permit Expires On: 10/26/2019 Owner: Name: Address: WESTFIELD PROPERTY TAX DEPT P0BOX BU94O'Q0LS8A�WA, 92013 Contact Person: Name: EL|K4CBEE Address: lUl1EMAIN SUITE, 205B'PUYALLUP, WA,9O37Z Contractor: Name: METRO AIR INC Address 1144712VTHAVE NE#2UU' K|RKLAND,VVA 98033 License No: METROA1995RC Lender: Name: ''' Phone: (425)658-7664 Expiration Date: 12/3/2019 DESCRIPTION OF WORK: REPLACE AN EXISTING COMMERCIAL GREASE HOOD WITH A NEW HOOD IN A NEW LOCATION. EXTEND EXISTING MAKE-UP AIR AND GREASE DUCTS TOTHE NEW HOOD LOCATION, ALL OTHER HVACEOU|PTN1ENTAND SYSTEMS ARE EXISTING, SOME DIFFUSERS WILL BERELOCATED TDMATCH THE NEW SPACE CONFIGURATIONS, Valuation of Work: $0.00 Type ofWork: Fve|type: Fees Collected: $797.14 Electrical Service Provided by: PUGETSOUND ENERGY Water District: TUKvv|U\ SewerDistrict: 0KW|LA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: international Mechanical Code Edition: Uniform Plumbing Code Edition. International Fuel Gas Code: Permit Center Authorized Signature 2015 2015 2015 2015 2015 National Electrical Code: VVACities Electrical Code: Vv4[29646B: WA State Energy Code: 2017 2017 2017 2015 Date: q� 0 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws r gulating construction or the performance of work, I am authorized to sign and obtain this development per it and agree to th'conditions ached tgr` is permit. Signature: Print Name: AQ� Da This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: The attached set of mechanical plans have been reviewed by The Tukwila Fire Marshals Office and are acceptable with the following concerns: 2: A Type 1 hood shall be installed at or above all commercial cooking appliances and domestic cooking appliances used for commercial purposes that produce grease vapors. Each required commercial kitchen exhaust hood and duct system required by section 610 of the International Fire Code to have a Type 1 hood shall be protected with an approved automatic fire -extinguishing system installed in accordance with this code. (IFC 904.2.1 and IFC 904.11) Automatic fire -extinguishing systems shall comply with UL 300 or other equivalent standards and shall be installed in accordance with the requirements of the listing. (NFPA 96, 10.2.3) 3: All new automatic fire -extinguishing systems and all modifications to existing automatic fire -extinguishing systems shall have fire department review and approval of drawings prior to installation or modification. 4: Local U.L. central station supervision is required. (City Ordinance #2437) 5: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 6: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 7: Portable fire extinguishers shall be provided within a 30-foot (9144 mm) travel distance of commercial -type cooking equipment. Cooking equipment involving vegetable or animal oils and fats shall be protected by a Class K rated portable extinguisher. (IFC 904.12.5) 8: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 9: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 10: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 11: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. 12: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 13: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 14: When special inspection is required, either the owner or the registered design professional in responsible charge shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection, The special inspector shall furnish inspection reports to the Building Official in xtimely manner. 15: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall besubmitted tothe Building Official. The final inspection report shall beprepared bythe approved special inspection agency and shall be submitted to the Building Official prior to and as a condition offinal inspection approval. 16: All construction shall bedone inconformance with the Washington State Building Code and the Washington State Energy Code. 17: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based unsatisfactory completion ufthis requirement. 18: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City ofTukwila Building Department (2O6~431-3G7U). 19: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 20t VALIDITY 0FPERMIT: The issuance o/granting ofapermit shall not beconstrued tobeapermit for, o/an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming togive authority toviolate nrcancel the provisions ofthe code orother ordinances cfthe City nfTukwila shall not bevalid. The issuance ofapermit based onconstruction documents and other data shall not prevent the Building Official frpmrequiringthecorrecdonofermrsin the construction documents and other data, Zl: `MECHANICAL PERMIT CONDITIONS' ZZ: All mechanical work shall beinspected and approved under aseparate permit issued bythe City ofTukwila Permit Center (20G/43l'367U). 23: Manufacturers installation instructions shall be available on the job site at the time of inspection. 24: Type 1Hoods, the required grease duct leakage test and light test shall beperformed byaspecial inspection and testing agency |naccordance with LK8I.Chapter 5. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (2n6}438'g350 1800 MECHANICAL FINAL 0609 P|P[/DU[T|NSULAT|UN 0701 ROUGH'|NKAECHAN|CAL 0702 SMOKE DETECTOR TEST 0710 TYPE 2HOOD AND DUCT CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No.2, \ ().0(-4; Project No. Date Application Accepted:, Date Application Expires: (For o ceuse only MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** Site Address: King Co Assessor's Tax No.: 262304-9023 468 Southcenter-Paikwny, Tukwila, WA 98188 Suite Number: Tenant Name: Trappers Sushi PROPERTY OWNER Name: Trappers Sushi Address: 718 Griffin Ave., #940 City: Enumclaw State: WA Zip: 98023 CONTACT PERSON — person receiving all project communication , Name: Eli McBee Address: loll E. Main, Suite 205B City: Puyallup State: WA Zip: 98372 Phone: (253) 691-0555 Fax: Email: eli@em-precision.com Floor: New Tenant: 0 _Yes fl ..No MECHANICAL CONTRACTOR INFORMATION Company Name: Metro Ail, Inc. Address: 11447 120th Ave. NE, #200 City: Kirkland State: WA Zip: 98033 Phone: (425) 658-7664 Fax: (425) 658-7691 Contr Reg No.: METROA1945RC Exp Date: 12/30/2019 Tukwila Business License No. BUS-0999024 Valuation of project (contractor's bid price): $ Describe the scope of work in detail: Replace an existing commercial grease hood with a new hood in a new location. Extend existing make-up air and grease ducts to the new hood location. All other HVAC equipment and sytems are existing. Some diffusers will be relocated to match the new space configurations. 45,000 Use: Residential: New Replacement EJ Commercial: New Replacement Fuel Type: Electric D Gas Other: H: \Applications\Forms-Applications On Line \2016 Applications \Mechanical Permit Application Revised 1-4-16.docs Revised: January 2016 bh Page I of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refriWcooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser 13 Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-10PM, Monday through Friday and SAM-10PM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (7am-lOpm); Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 07/MT 0 ZED AGENT: Signature: Date: 03/14/2019 Print Name: Eli McBee Day Telephone: (253) 691-0555 Mailing Address: 1011 E. Main, Suite 205B Puyallup WA 98372 City State Zip HAApplications L Forms -Applications On Line\2016 ApplicationsNechanical Permit Application Revised 1-4-16.docii Revised: January 2016 bh Page 2 az fig Cash Register Receipt City of Tukwila DESCRIPTIONS I PermitTRAK ACCOUNT I QUANTITY PAID $72.10 M19-0043 Address: 468 SOUTHCENTER MALL Apn: 9202470010 $72.10 Credit Card Fee $2.10 Credit Card Fee R000.369.908.00.00 0.00 $2.10 MECHANICAL $70.00 ADDITIONAL PLAN REVIEW TOTAL FEES PAID BY RECEIPT: R18454 R000.345.830.00.00 1.00 $70.00 $72.10 Date Paid: Thursday, August 29, 2019 Paid By: MICHELLE DUNN Pay Method: CREDIT CARD 064760 Printed: Thursday, August 29, 2019 11:14 AM 1 of 1 Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT ' QUANTITY PAID PermitTRAK $1,454.94 M19-0043 Address: 468 SOUTHCENTER MALL Apn: 9202470010 $797.14 MECHANICAL $766.48 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000,322,100,00.00 0.00 $580.03 PLAN CHECK FEE R000,322.102.00.00 0.00 $153.30 TECHNOLOGY FEE $30.66 TECHNOLOGY FEE R000.322.900.04.00 0.00 $30.66 PG19-0044 Address: 468 SOUTHCENTER MALL Apn: 9202470010 $657.80 GAS $147.50 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $35.00 PERMIT FEE R000.322.100.00.00 0.00 $83.00 PLAN CHECK FEE R000.322.103.00.00 0.00 $29.50 PLUMBING $485.00 PERMIT FEE R000.322.100.00.00 0.00 $353.00 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $35.00 PLAN CHECK FEE R000.322.103.00.00 0.00 $97.00 TECHNOLOGY FEE $25.30 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R17170 R000.322.900.04.00 0.00 $25.30 $1,454.94 Date Paid: Friday, March 15, 2019 Paid By: EM PRECISION LLC Pay Method: CHECK 045842 Printed: Friday, March 15, 2019 11:51 AM 1 of 1 SYSTEMS CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA 0017340000802374464500 Date: 08/29/2019 11:13:46 AM CREDIT CARD SALE MASTERCARD CARD NUMBER: **********2826 K TRAN AMOUNT: $72.10 APPROVAL CD: 064760 RECORD #: 000 CLERK ID: kandace X {CARDHOLDER'S SIGNATURE} I AGREE TO PAY THE ABOVE TOTAL AMOUNT ACCORDING TO THE CARD ISSUER AGREEMENT (MERCHANT AGREEMENT IF CREDIT VOUCHER) Thank you! Merchant Copy INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 Permit Inspection Request Line (206) 438-9350 Project: rilinPPAMS cxJs%/-/ Type of Inspection: 5/(4 Adddrreess: ,Date Called: Special Instructions: Date Wanted: a.m. Requester: Phone No: Approved per applicable codes. [1 Corrections required prior to approval. !COMMENTS: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431w3670 Permit Inspection Request Line (206) 438-9350 Project: / 'Type oi` inspectio : Address: pate Called: pedal instructions: .771, jec 27, 1)X- Date Wanted: 66 30-71 a.m.J P-m. Requester: Phone No: 253 3Z [:-.] Approved per applicable codes. orrections required prior to approval. COMMENTS: �T R0116/7` �' r.. A l. Ins pectot: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Cait to schedule reinspection. 2 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 M19-0043 . , 1 rQ#1=Aiver's Sushi Trip66pg [7- e c.tj o n i yp'e I Hood Address: 468 Southcenter Mali Date Called: Special Instructions: Date Wanted: 5/31/19 a.m. p.m• Requester: Phone No: DiApproved per applicable codes. Corrections required prior to approval. COMMENTS: This is correction comments nnticert nn FIVA insp - •• • • - . - - • •• • - •IIII I- - 0-'4 called for the Type I Hood. RFI request. Existino ductwork and fan do not meet minimum Mechanical Code require ents for Type 1 Hood. Please provide Mechanical Engineering with calculations for review and approval. 1. Prevention of grease accumulation in grease ducts. Type I hood shall be constructed and installed so that grease cannot collect in any portion thereof. and shall slope not less th. n one-foioth unit vertical in 12 units horizontal toward the hood or toward a grease reservoir designed and installed in accordance with Section 506.3.7.1 where horizontal ducts exceed 75 feet in length, the slope shall be not less than one unit vertical in 12 units horizontal. 201 5 IMC 506.3.7 2. Grease duct cleanouts and openings. Spaced not more than 20' apart and not more than 10' from changes in direction greater than 45 degrees. 2015 IMC 506.3.8 2. 3. Grease duct horizontal cleanouts. Not more than 20' from changes in direction that are greater than 45 degrees. 2015 IMC 506.3.9. 4. Grease duct termination on roof does not have rain weather protection. or access to clean. 5. Verify exhaust fan motor capacity and intake fan motor capacity for duct length exceeding 100'. 6. Verify vibration isolation per 2015 IMC 506.3.2.4 7. -rease duct test. Leakage test. 6 light test shall be performed to determine that all welded and brazed joints are liquid tight. 2015 IMC 506.3.2.5 Inspector: BLS Date: 05/31/19 Ell REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be 1-11 paid at 6300 Southcenter Blvd.. Suite 100. Cali to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT N10. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project; Tip" -PP �L S'oS -! Type ol• lns +action_ r�- `N / 4€ct JtC4c.- Ad ress: Date Called: - pedal Instructions: Date Wanted: 5" a.m. p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: i Inspector: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must- be paid at 6300 Southcenter Blvd.. Suite 100. Galt to schedule reinspection. Page 1 of 2 sue-: AM MIL al MIMI I(.I'2I.z:;a.r:I&Associates,1nc. Geotechnical Engineering • Environmental Engineering Construction Testing and Inspection DATE: 9/3/2019 Field Report NO.: 06619182DFR932019MZ Set Count: CONTRACT • rr ' -cision PROJECT #: 06619182 PERMIT M19-0043 PROJECT: Trappers Sushi INSPECTOR: ' . - w Zukowski LOCATION: 280 Southcenter BLVD 468 JURISDICTION: City of Tukwilla KA P.M.: WBT WEATHER: Partly Cloudy TEMP: 70° F A representative of Krazan and Associates arrived on site per request for welding and fire wrap inspection. Light inspection was performed on grease duct welds. In seating area 3 reservoirs were tested as well as 1 Kitchen in the west and one transition segment. All seal welds found to be acceptable at time of inspection. Firewrap was applied to exposed areas of grease trap. Placement was in conformance with plan and manufacture specifications. Two layers were placed per manufacturer's recommendations. Support hangers in place per manufacturer's recommendations. [Weld locations] RECEIVED TV OF TUKWILA SEP 0 4 2019 IRMIT CENTER [Firewrap] Offices Serving the Western United States Lynnwood (425) 485-5519 • Poulsbo (360) 598-2126 • Tacoma (253) 939-2500 The information provided on this report is prepared for the exclusive use of the client. This report may not be reproduced in any format without the written permission of the client and Krazan & Associates. This regal indicates our inspectors observation and testing molts boxed on site conditions and contractor activities. This information is subject to review prior to final submittal. By signing this report, our inspector does not accept responsibility for validity of results. The same information has been provided by others on site, Page 2 of 2 Sha INS. All dlIWI azan &Associates, Inc. Geotechnical Engineering • Environmental Engineering Construction Testing and Inspection Field Report NO.: 06619182DFR932019MZ Reviewed By: ASTM Test #: Asset Number(s): To the best of my knowledge, the above WAS performed in accordance with the approved plans, specifications and regulatory requirements. Superintendent/Representative: Technician: Offices Serving the Western United States Lynnwood (425) 485-5519 • Poulsbo (360) 598-2126 • Tacoma (253) 939-2500 The information provided on this report is prepared for the exclusive use of the client. This report may not be osprofuced in any format without the written permission of the client and Kmzan & Associates. This report indicates our inspector observation and testing results based on site conditions and contractor activities. This information is subject to review prior to final submittal. By signing this report. our inspector does not accept responsibility for validity of results. The same infornnttion has been provided by others on site. City of Tukwila Department of Community Development April 10, 2019 ELI MCBEE 1011 E MAIN SUITE, 205B PUYALLUP, WA 98372 RE: Correction Letter # 1 MECHANICAL Permit Application Number M19-0043 TRAPPER'S SUSHI - 468 SOUTHCENTER MALL Dear ELI MCBEE, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING - M DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL INFORMATION NO E.) PLAN SUBMITTALS: (Min. size 11x17 to a preferably maximum size of 24x36; all sheets shall be the same size; larger sizes may be negotiable. "New revised" plan sheets shall be the same size sheets as those previously submitted.) "STAMP AND SIGNATURES" (If applicable) For Engineers: "Every page of a plan set must contain the seal/stamp, signature of the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature. Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp, signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a bound specification document that contains specifications other than that of an engineering or land surveying nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is responsible." It shall not be required to have each page of "specifications" (calculations) to be stamped and signed; Front page only will be sufficient (WAC 196-23-010 & 196-23-020). Architects: "date" only not required (WAC 308-12-081). (BUILDING REVIEW NOTES) 1. Plans are not stamped by the architect. Please provide plans where all sheets are stamped and signed by the architect. See general note above. 2. It could not be verified on the plans provided where the previous hood system was removed. Provide information on the plans to show location of the previously removed hood and verify the new duct system is sized to the existing ducts and length of the existing ducts shown. Provide details for the duct cleanouts and show where located on the plan. Specify length and sloping of the ducts. (IMC 506.3.7 & 506.3.8) 3. Provide the missing duct and hood plans by Captive Air. Those sheets shall be included with the mechanical permit for the Type I hood. Note: Contingent on response to these corrections, further plan review may request for additional corrections. 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. Jazzel Salazar Permit Technician File No. M19-0043 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COP'(° PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M19-0043 PROJECT NAME: TRAPPER'S SUSHI SITE ADDRESS: 468 SOUTHCENTER MALL Original Plan Submittal Response to Correction Letter # DATE: 08/19/19 Revision # before Permit Issued X Revision 1 after Permit Issued DEPARTMENTS: t1 tiding Division cig Public Works Fire Prevention Structural Planning Division Permit Coordinator LI • PRELIMINARY REVIEW: Not Applicable (no approval/review required) REVIEWER'S TIALS: DATE: 08/20/19 Structural Review Required DATE: LI APPROVALS OR CORRECTIONS: Approved Corrections Required n DUE DATE: 09/17/2019 Approved with Conditions n Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire El Ping 0 PW 0 Staff Initials: 12/18/2013 c PERMIT COORD COP PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M19-0043 PROJECT NAME: TRAPPER'S SUSHI SITE ADDRESS: 6101 S 180 ST Original Plan Submittal X Response to Correction Letter # 1 DATE: 04/17/19 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Building Division k\N° Public Works Fire Prevention Structural LI n Planning Division Permit Coordinator E r PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 04/18/19 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Approved with Conditions Denied (ie: Zoning Issues DUE DATE: 05/16/19 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg El Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 ERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M19-0043 PROJECT NAME: TRAPPERS SUSHI SITE ADDRESS: 468 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # DATE: 03/15/19 Revision # Revision # before Permit Issued after Permit Issued DEPARTMENTS: AT CM Building Division Public Works Fire Prevention Structural Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) REVIEWER'S INITIALS: DATE: 03/19/19 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews DUE DATE: 04/16/19 Approved with Conditions Denied (ie: Zoning Issues Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MA Departments issued corrections: ED Ur - Ping 0 PW Staff Initials: 12/18/2013 PROJECT NAME: trij s1-6 SITE ADDRESS: Li ft, aitt.c ..eyy MA 11 PERMIT NO: M II- 00413 ORIGINAL ISSUE DATE: 4 .4 REVISION LOG REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF 7'IALS 251- 1 ct Summary of Revision: Co rretA-4Tenr. 41 pe 1 T 64 Received by: REVISION NO. DATE DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received b : (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) City of Tukwila REVISION SUBMITTAL Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: CV/9,5 Plan Check/Permit Number: LJ Response to Incomplete Letter # El Response to Correction Letter # RECEIVED Fil Revision # before Permit is Issued CITY OF TUKWILA. O Revision # / after Permit is Issued AUG 19 2019 • Revision requested by a City Building Inspector or Plans Examiner E] Deferred Submittal # PERMIT CENTEP Project Name: / Project Address: v6 9 S"-or Contact Person: /e7z7Z05.s • lAc,‘ Summary of Revision: T-9 Phone Number: 3), 9 ,3 .2 Sheet Number(s): "Cloud" or highlight all areas of revision including date ofrevision Received at the City of Tukwila Permit Cent Entered in TRAKiT on Pf 9 --/ 9 Maus \Kandace-N AppData \Local \Microsoft Windows \INetCache\ Content.Outlook \QI3S I 8YWCalievision Submittal Form.doc City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: Plan Check/Permit Number: M19-0043 O Response to Incomplete Letter # Z Response to Correction Letter # _l_ O Revision # after Permit is Issued O Revision requested by a City Building Inspector or Plans Examiner O Deferred Submittal # Project Name: TRAPPERS SUSHI Project Address: 468 SOUTHCENTER MALL Contact Person: "C- L.,/c til)c Phone Number: g5 — 555 Summary of Revision: cJr6,0 M c / 0 )>)tAie tr51140,Ac, nEcEivEn CITY OF TUKWILA APR 1 7 2019 PERMIT CENTER Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in TRAKiT on 11 ocN, S'ccecncr WAPermit Center (Rechelle)\FormsWermit Center Documents (WordNievision Submittal Fomtdoc Revised: August 2015 METRO AIR INC Homo. Espaliol Contact Page 1 of 2 Search L&I Safety & Health Claims & Insurance Washington State Department oi 40 Labor & Industries A-Z Index Help My 1,&:1 Workplace Rights Trades & Licensing METRO AIR INC Owner or tradesperson Principals SCHEFFLER, MICHAEL ALLEN, PRESIDENT HANLON, ASH T, VICE PRESIDENT Doing business as METRO AIR INC WA UBI No. 602 156 865 11447 120th Ave. NE #200 KIRKLAND, WA 98033 425-658-7664 KING County Business type Corporation Governing persons ASH T HANLON MIKE A SCHEFFLER; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties Heating/Vent/Air-Conditioning and Refrig (HVAC/R) License no. METROAI995RC Effective — expiration 12/03/2001— 12/03/2019 Bond CBIC Bond account no. 5E0682 Active. Meets current requirements. $6,000.00 Received by L&I Effective date 12/03/2001 11/15/2001 Expiration date Until Canceled Insurance American States Insurance Co $1,000,000.00 Policy no, bka53356859 Received by L&I Effective date 11/02/2018 11115/2018 Expiration date 11/15/2019 Insurance history Savings No savings accounts during the previous 6 year period. Help us improve •4 irs •1 OT r_frrt 1cco C 0_ T T r,-1% T7 fl A T C ry 0.0 A NI 7— A PIO PI (11 fl METRO AIR INC Lawsuits against the bond or savings No lawsuits against the bond or savings acco.....J during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. This company has multiple workers' comp accounts. Active accounts L&I Account ID 022,469-01 Account is current. Doing business as METRO AIR INC Estimated workers reported Pending current quarter filing L&I account contact Ti 1 JAN BENTLEY (360)902-4652 - Email: STR0235@lni.wa.gov Track this contractor 0 Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 05/01/2014 Inspection no. 317228070 Location 3580 Wheaton way Bremerton, WA 98310 Violations Page 2 of 2 ff7d Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of VVashington. Help us improve httns://secure.lni.wa.goviverifv/Detail.asnx?UBI-602156865&1-10---METROAI995RC&SAW= 4/29/2019 I A I B D I E I F G 2 J K L N O QTukwlla Municipal Court Ham lion Inn Sargh SalotiCentric I Sra P,Lr,,ou,hcent t 4'nrvr `y0 ^ Southcentel plvd z. �. � n � Ext.ndd stay 1-enee. 19 5 :. b -Staple- Soullw nler 1 Tukw� Pkwy - ' - r� Buffa:o Wild Wimp; Tukwila Pkwy ..,hama [Breeze �r� I'r. +� r erg i F L Y 4 Besil's Reswuralit (* and Lounge w QLowe's Home 41. Improvement EmLa sy Suites by °f S Seafood City fii Bowlero South Seattle PedEx Office Print rllhcn eatlleTloofna._ o Macy's Supermarket & Ship Center Green Rt,;er Nordstrom5outhcerrter -s, ,ot nr l tltyludGyk:vnolt+ - tUc Sift Tac Areu p Westfield Southcenter LA FIIness F - ' Q JCPenneyQ 0,1� It'd _ ncXrr errd Renfdl n ,; ("o by Marliotl Scalllw c 468 Southcenter Mall Wendy's 9 Acura Seattle t, of rj I Taco BeL' SmartFoodservice REI `d' Warehouse Stores Jack in the Box 1 The Cho I secake r u.l try Clive Garden 11;;1611 Blcenlehnlal Park„s crCheyron sl1a 7) L Target Segale Center Q Slarbucks Seattle Exchange @ Soullicenter 3 DollarTree9 Nursing Assistant . 0 DoubluTrLe Suiis by t tilt.ln Hotel �iatlle... Barnes& Noble Training . Mc(?nnald s V Wells Fargo Bank r' Tukwila Pond Park 1 Go• gle ? Bullar & Cantor L WORK LOCATION VICINITY MAP D NO SCALE NORTH 4 5 ENTRANCE/ EXIT IF 7 0 • ENTRANCE/ EXIT WORK LOCATION 9 SITE PLAN XXll� NO SCALE a NORTH I% COMMISSIONING: 1. AIR BALANCE AND OUTSIDE AIR REQUIREMENTS PER BALACING CRITERIA SHALL BE PERFORMED BY THE CONTRACTOR IN COMPLIANCE WITH 2O15 WSEC SECTION C408. A I B C V YVI%IN LV V/1I IVIII W1111111 0 NO SCALE 2015 INTERNATIONAL MECHANICAL CODE (IMC X \r., NORTH 1. EXHAUST, MAKE-UP AIR SYSTEM AND TYPE 1 HOODS EQUIPMENT HAS BEEN SELECTED BY OTHERS. 2. (E) SPECIAL DUCT FOR TYPE 1 GREASE HOODS SHALL BE IN COMPLIANCE WITH 2O15 IMC CODES. 3. AIR SYSTEMS SHALL BE BALANCED AS REQUIRED IN SECTION C408.2.2.1 AND C408.2.2.2 OF THE WSEC (TYPE 1 HOODS). 4. AIR BALANCE SHALL BE PERFORMED BY THE CONTRACTOR OR A QUALIFIED AIR BALANCE CO., FOR THE TYPE 1 HOODS. 5. VERIFY THAT OUTSIDE AIR INTAKES, EXHAUST OUTLETS AND RELIEF OUTLETS ARE PROVIDED WITH DAMPERS THAT COMPLY WITH WSEC C403.2.4.4. DAMPER SHALL AUTOMATICALLY CLOSE WHEN SYSTEM OR SPACES SERVED ARE NOT IN USE OR DURING WARM-UP, COOL -DOWN, AND SETBACK. DAMPER MAXIMUM LEAKAGE RATE SHALL NOT EXCEED MAXIMUM ALLOWED BY WSEC C402.4.5.2. HVAC NOTES: 1. THE EXISTING TYPE 1 HOOD INStALLATION SHALL BE COMPLETE WHEN ALL SECTIONS OF IMC HAVE BEEN VERIFIED, WHERE APPLICABLE FOR THE SYSTEM. 2. ANY SYSTEM INDICATED ON THE PLANS SHALL NOT EXCEED A 1/2" W.C. STATIC PRESSURE GENERAL TYPE 1 HOOD NOTES - IMC COMPLIANCES: (SEE M0.1 FOR ADDITIONAL NOTES) (REFERENCE ONLY - VERIFY) 1. (E) MAKE-UP AIR SYSTEM SHALL BE ELECTRICALLY INTERLOCKED WITH THE EXHAUST SYSTEM, SUCH THAT THE MAKE-UP AIR SYSTEM WILL OPERATE WHEN THE EXHAUST SYSTEM IS IN OPERATION. 2. (E) MAKE-UP AIR SHALL BE PROVIDED BY A MECHANICAL OR GRAVITY MEANS OF SUFFICIENT CAPACITY. WINDOWS AND DOOR OPENINGS SHALL NOT BE USED FOR THE PURPOSE OF PROVIDING MAKE-UP AIR. MOTORIZED DAMPER REQUIRED AT OPENINGS. (MAKE-UP AIR FAN - MUA -1) 3. THE TEMPERATURE DIFFERENTIAL BETWEEN MAKE-UP AIR AND THE AIR IN THE CONDITIONED SPACE SHALL NOT EXCEED 10OF IF THE AMOUNT OF MAKE-UP AIR EXCEEDS 2,500 CFM PER SPACE. SLOPE OF DUCT AND CLEANOUT ACCESS (506.3.7, 506.3.8) 1. HORIZONTAL DUCT UP TO 75' LONG MIN SLOPE 1/4 IN/FT MORE THAN 75' LONG MINE SLOPE 1 IN/FT 2. GREASE DUCT HORIZONTAL TIGHT -FITTING CLEANOUT DOORS SHALL BE SPACED NOT MORE THAN 20 FT APART, LOCATED NOT MORE THAN 10 FT FROM CHANGES IN DIRECTION THAT ARE GREATER THAN 45 DEGREES AND LOCATED AT GREASE RESERVOIRS. GREAT DUCT VERTICAL TIGHT -FITTING CLEANOUT DOORS SHALL BE PROVIDED MINIMUM ONE ON EACH FLOOR WHERE GREASE DUCTS PASS VERTICALLY THROUGH FLOORS. DUCT ENCLOSURE (506.3.11, 506.3.12) (VERIFY EXISTING) 1. DUCTS PENETRATING A CEILING, WALL OR FLOOR SHALL BE ENCLOSED IN A DUCT ENCLOSURE HAVING FIRE RATING PER SBC TABLE 601 FROM THE POINT OF PENETRATION TO THE OUTSIDE AIR. A DUCT MAY ONLY PENETRATE EXTERIOR WALLS AT LOCATIONS WHERE UNPROTECTED OPENINGS ARE PERMITTED BY TABLE 705.8 OF THE BUILDING CODE. 2. FOR CODE COMPLIANCE PURPOSES, IT IS ACCEPTABLE TO ASSUME THAT DUCTS PENETRATING CONCRETE, BRICK OR STEEL CEILINGS, WALLS OR FLOORS SHALL REQUIRE A 2-HOUR FIRE -RESISTIVE DUCT ENCLOSURE, AND FOR OTHERS, IT SHALL BE 1 HOUR. 3. ALL JOINTS AND SEAMS SHALL BE MADE WITH CONTINUOUS LIQUID -TIGHT WELD OR BRAZE MADE ON THE EXTERNAL SURFACE OF DUCT SYSTEM. VIBRATION INSULATION CONNECTOR MAY BE USED PROVIDED IT CONSISTS OF NONCOMBUSTIBLE PACKING IN A METAL SLEEVE JOINT. (506.3.2, 507.7) 4. EXHAUST FANS USED FOR DISCHARGING GREASE EXHAUST SHALL BE POSITIONED SO THAT THE DISCHARGE WILL NOT IMPINGE ON THE ROOF. THE FAN SHALL BE PROVIDED WITH AN ADEQUATE DRAIN OPENING AT THE LOWEST POINT TO PERMIT DRAINAGE OF GREASE TO A SUITABLE COLLECTION DEVICE. (506.5.2) EXHAUST FAN SHALL BE GREASE RATED 5. TIGHT -FITTING HINGED ACCESS DOOR SHALL BE PROVIDED AT EACH CLEANOUT. ACCESS ENCLOSURE DOORS SHALL HAVE FIRE -RESISTANCE RATING EQUAL TO THE ENCLOSURE. AN APPROVED SIGN SHALL BE PLACED ON ACCESS DOOR. "ACCESS PANEL. DO NOT OBSTRUCT." 6. TOTAL COMPLIANCE WITH 20151MC, SECTION 505,506 & 507 ARE REQUIRED. E I F SYMBOL DESCRIPTION 20/12 DUCT (FIRST FIGURE, SIDE SHOWN) 20/12L 20l12L* LINED DUCT (DIM. FOR NET FREE AREA). EOL=END OF LINING. L* = 2" THICK LINING. R (D) RISE (R) OR DROP (D). ARROW IN DIRECTION O FLOW. ® DUCT SECTION (SUPPLY) DUCT SECTION (EXHAUST OR RETURN) jo ROUND DUCT, DIAMETER VOLUME DAMPER (MANUAL) [' MOTORIZED DAMPER FLEXIBLE CONNECTION BACK DRAFT DAMPER (BDD) FLEXIBLE DUCT FIRE DAMPER COMBINATION FIRE/SMOKE DAMPER ELBOW WITH TURNING VANES ® SIZE,SYMBOL CEILING OUTLET CFM CEILING INLET ZSIZE,SYMBOL CFM SIZE,SYMBOL Cam-__ WALL OUTLET (OR INLET) O THERMOSTAT n V� THERMOSTAT WITH GUARD T THERMOSTAT AVERAGED WITH ANOTHER A THERMOSTAT O SWITCH ® OCCUPANCY SENSOR IT INTERVAL TIMER CONDENSATE LINE GAS LINE 2 DETAIL VIEW SYMBOL 4 THE EXAMPLE AT LEFT IS THE SYMBOL FOR DE 0 M -1 VIEW 2, DECLARING THAT DETAIL VIEW 21S SH . Doi /�� 4461 Rep U � � 14 s,5;c5 � G H mfelvilm DESCRIPTION O APPROX APPROXIMATELY vv ARCH ARCHITECTURAL AUTO AUTOMATIC BDD BACK DRAFT DAMPER F BLDG BUILDING BTU BRITISH THERMAL UNIT BTUH BRITISH THERMAL UNIT PER HOUR C CONDENSATE - CAP CAPACITY CFM CUBIC FEET PER MINUTE _ _ _ CLG CEILING CO CLEANOUT REVISI NS " COMB COMBINED, COMBINATION No ct-tanaes shall ben ade to the scope COND CONDENSER, CONDENSATE of work witnout of lot approval of the CONN CONNECTION t, -1 Tukwila Buildin Division. CONT CONTINUE, CONTINUATION NOTE: Revisions will quire a new plan DB DRY BULB submittal and may include dditional plan review. DEG F, F° DEGREE FAHRENHEIT DIA, 0 DIAMETER DN DOWN 3 DOAS DEDICATED OUTSIDE AIR SYSTEM DTL DETAIL DWG DRAWING EA EACH EER ENERGY EFFICIENCY RATIO EFF EFFICIENCY ELEC ELECTRICAL, ELECTRIC EOL END OF LINING ESP EXTERNAL STATIC PRES RE FILE CO EXH EXHAUST Pam* No. (E) EXISTING Plan review approval is subject to errors ana EXIST EXISTING omissions. Approval of constructio documents FCO FLOOR CLEAN OUT not authorize the violation of any, dopted code or FL FLOOR ordinance. Receipt of approved field Copy and FLA FULL LOAD AMPS conditions is acKnowl ged: FLEX FLEXIBLE By. FPM FEET PER MINUTE Date: City of Tukwila GAL GALLON BUILDING DIVISlo GALV. GALVANIZED GI GREASEINTERCEPTOR HACR HEATING AIR-CONDITIONING AND REFRIGERATION HP HORSE POWER HSPF HEATING SEASONAL PERFORMANCE FACTOR I.E. INVERT ELEVATION IN INCH INTEGR. INTEGRAL IWG INCH OF WATER GAUGE KW KILOWATT LB POUND LRA LOCKED ROTOR AMPS TAIL MAX MAXIMUM WN MBH THOUSAND BTUH MCA MINIMUM CIRCUIT AMPS MECH MECHANICAL MFR MANUFACTURER MIN MINIMUM ON MOP MAXIMUM OVERCURRENT PROTECTION MTL METAL, AS IN "SHEET METAL" MUA MAKE-UP AIR 6 NIC NOT IN CONTRACT NO. NUMBER NTS NOT TO SCALE CIA OUTSIDE AIR OBD OPPOSED BLADE DAMPER OFCI OWNER FURNISHED, CONTRACTOR INSTALLED PD PRESSURE DROP PH PHASE PLCS PLACES QTY QUANTITY RA RETURN AIR REF REFERENCE REQ'D REQUIRED RG REFRIGERANT GAS RL REFRIGERANT LIQUID RLA RATED LOAD AMPS RM ROOM 7 RPM REVOLUTIONS PER MINUTE SA SUPPLY AIR SCO SURFACE CLEANOUT SCR SILICON CONTROLLED RECTIFIER SEER SEASONAL ENERGY EFFICIENCY RATIO SHT SHEET, AS IN "SHEET METAL" TD TRANSFER DUCT 8 TEMP TEMPERATURE FEE JFRV TG TRANSFER GRILLE THRU THROUGH APPROVED TYP TYPICAL UNO UNLESS NOTED OTHERWISEV VOLTS, VOLTAGE, VENT VFD VARIABLE FREQUENCY DRIVEW WASTE W/ WITH WA WATT WB WET BULB WL WALL LOUVER 9 WT WEIGHT M0.0 M0.1 M1.0 M1.1 DRAWING INDEX �,sy ,r�;ED KWILA MECHANICAL LEGEND & NOTES AU 19 2019 SCHEDULES & SPECIFICATIONS JPERfoff CENTER HVAC - PLAN HVAC - PLAN ,.P�,• ER=7rr,�. RENEW: 8/2021 J N �O � O st J J J zWavto N (.5 zWf" W II W J goYCQ V /c/� V mow U elm c z � ma p J ujuQ: r } W O � E a U Z ' 0O rn � Q o -- < o _ 0 Cr/ ♦ W - M W LJIJ W I-- W WF_W W W 0- U - CL O �_� `��~ W 3;i�.. W W o �. w .� >I- h=- N 06 U) W l_ O M o8 Z Q Q rn W III0 ) w - J W Z U W W (~j Z r = U W F- W W D' ZO Z --t U Z O W C6 W (n � T F- W W WZ d W I- O _ Q C/) © f0 [l W QTY QUANTITY RA RETURN AIR REF REFERENCE REQ'D REQUIRED RG REFRIGERANT GAS RL REFRIGERANT LIQUID RLA RATED LOAD AMPS RM ROOM 7 RPM REVOLUTIONS PER MINUTE SA SUPPLY AIR SCO SURFACE CLEANOUT SCR SILICON CONTROLLED RECTIFIER SEER SEASONAL ENERGY EFFICIENCY RATIO SHT SHEET, AS IN "SHEET METAL" TD TRANSFER DUCT 8 TEMP TEMPERATURE FEE JFRV TG TRANSFER GRILLE THRU THROUGH APPROVED TYP TYPICAL UNO UNLESS NOTED OTHERWISEV VOLTS, VOLTAGE, VENT VFD VARIABLE FREQUENCY DRIVEW WASTE W/ WITH WA WATT WB WET BULB WL WALL LOUVER 9 WT WEIGHT M0.0 M0.1 M1.0 M1.1 DRAWING INDEX �,sy ,r�;ED KWILA MECHANICAL LEGEND & NOTES AU 19 2019 SCHEDULES & SPECIFICATIONS JPERfoff CENTER HVAC - PLAN HVAC - PLAN ,.P�,• ER=7rr,�. RENEW: 8/2021 J N �O � O st J J J zWavto N (.5 zWf" W II W J goYCQ V /c/� V mow U elm c z � ma p J ujuQ: r } W O � E a U Z ' 0O rn � Q o -- < o _ 0 Cr/ ♦ W - M W LJIJ W I-- W WF_W W W 0- U - CL O �_� `��~ W 3;i�.. W W o �. w .� >I- h=- N 06 U) W l_ O M o8 Z Q Q rn W III0 ) w - J W Z U W W (~j Z r = U W F- W W D' ZO Z --t U Z O W C6 W (n � T F- W W WZ d W I- O _ Q C/) © f0 [l W 7 RPM REVOLUTIONS PER MINUTE SA SUPPLY AIR SCO SURFACE CLEANOUT SCR SILICON CONTROLLED RECTIFIER SEER SEASONAL ENERGY EFFICIENCY RATIO SHT SHEET, AS IN "SHEET METAL" TD TRANSFER DUCT 8 TEMP TEMPERATURE FEE JFRV TG TRANSFER GRILLE THRU THROUGH APPROVED TYP TYPICAL UNO UNLESS NOTED OTHERWISEV VOLTS, VOLTAGE, VENT VFD VARIABLE FREQUENCY DRIVEW WASTE W/ WITH WA WATT WB WET BULB WL WALL LOUVER 9 WT WEIGHT M0.0 M0.1 M1.0 M1.1 DRAWING INDEX �,sy ,r�;ED KWILA MECHANICAL LEGEND & NOTES AU 19 2019 SCHEDULES & SPECIFICATIONS JPERfoff CENTER HVAC - PLAN HVAC - PLAN ,.P�,• ER=7rr,�. RENEW: 8/2021 J N �O � O st J J J zWavto N (.5 zWf" W II W J goYCQ V /c/� V mow U elm c z � ma p J ujuQ: r } W O � E a U Z ' 0O rn � Q o -- < o _ 0 Cr/ ♦ W - M W LJIJ W I-- W WF_W W W 0- U - CL O �_� `��~ W 3;i�.. W W o �. w .� >I- h=- N 06 U) W l_ O M o8 Z Q Q rn W III0 ) w - J W Z U W W (~j Z r = U W F- W W D' ZO Z --t U Z O W C6 W (n � T F- W W WZ d W I- O _ Q C/) © f0 [l W M0.0 M0.1 M1.0 M1.1 DRAWING INDEX �,sy ,r�;ED KWILA MECHANICAL LEGEND & NOTES AU 19 2019 SCHEDULES & SPECIFICATIONS JPERfoff CENTER HVAC - PLAN HVAC - PLAN ,.P�,• ER=7rr,�. RENEW: 8/2021 J N �O � O st J J J zWavto N (.5 zWf" W II W J goYCQ V /c/� V mow U elm c z � ma p J ujuQ: r } W O � E a U Z ' 0O rn � Q o -- < o _ 0 Cr/ ♦ W - M W LJIJ W I-- W WF_W W W 0- U - CL O �_� `��~ W 3;i�.. W W o �. w .� >I- h=- N 06 U) W l_ O M o8 Z Q Q rn W III0 ) w - J W Z U W W (~j Z r = U W F- W W D' ZO Z --t U Z O W C6 W (n � T F- W W WZ d W I- O _ Q C/) © f0 [l W Z ' 0O rn � Q o -- < o _ 0 Cr/ ♦ W - M W LJIJ W I-- W WF_W W W 0- U - CL O �_� `��~ W 3;i�.. W W o �. w .� >I- h=- N 06 U) W l_ O M o8 Z Q Q rn W III0 ) w - J W Z U W W (~j Z r = U W F- W W D' ZO Z --t U Z O W C6 W (n � T F- W W WZ d W I- O _ Q C/) © f0 [l W A I B I C I D I E I F I G n J K L 2 V. 6� 10 7 z a SPECIFICATIONS FO C A,OEXISTING } ju ROOFTOP GREASE R DUCT EXHAUST vT A & MAKE-UP AIR SYSTEM GENERAL: 1. CODE COMPLIANCE -ALL WORK SHALL COMPLY WITH ALL LOCAL CODES AND ORDINANCES. 4. HEATING SECTION FOR MUA-1 SHALL BE GAS FIRED TYPE WITH HEAT EXCHANGER TO PREVENT 2. DRAWINGS: DRAWINGS ARE DIAGRAMMATIC AND SHOW THE GENERAL ARRANGEMENT OF THE PRODUCTS OF COMBUSTION FROM COMING INTO CONTACT WITH HEATED SUPPLY AIR TO BUILDING. CONSTRUCTION AND THEREFORE DO NOT SHOW ALL NECESSARY OFFSETS, FITTINGS, AND HEAT EXCHANGER SHALL BE CONSTRUCTED OF CORROSION RESISTANT STEEL. HEATER SHALL HAVE ACCESSORIES WHICH ARE REQUIRED. INDUCED DRAFT OR FORCED AIR DRAFT FANS TO VENT PRODUCTS OF COMBUSTION. FAN SHALL BE INTERLOCKED TO UNITS GAS VALVE AND HEATING CONTROLS TO ALLOW PRE -PURGE OF UNIT PRIOR 3. FIELD VERIFICATION: CHECK FIELD CONDITIONS AND VERIFYING SPACE AVAILABLE FOR DUCTS BEFORE TO OPENING GAS VALVE AND ALLOWING COMBUSTION. IGNITION SHALL BE PILOTLESS, AND SHALL USE PROCEEDING WITH THE WORK. ELECTRIC IGNITION OR HOT SURFACE IGNITION SYSTEM. 4. WARRANTY: ALL WORK AND EQUIPMENT SHALL BE WARRANTED TO BE FREE FROM DEFECTS AND 5. FILTERS: UNIT(S) SHALL HAVE FILTER FRAME FOR HOLDING FILTER SIZES (OR FILTER FACE AREA) AS CAPABLE OF PROVIDING SATISFACTORY OPERATION FOR A PERIOD OF 1 YEAR AFTER FINAL SCHEDULED. FILTERS SHALL BE MEDIUM EFFICIENCY, PLEATED PANEL, DISPOSABLE TYPE ACCEPTANCE. (THROWAWAY) . FILTER MEDIA SHALL PROVIDE A MINIMUM OF MERV 8 EFFICIENCY WHEN EVALUATED UNDER ASHRAE 52.2. CAMFIL / FARR "30/30" (OR APPROVED EQUAL). 5. COMPLETE SYSTEMS: NOT ALL NECESSARY MATERIALS TO PERFORM THE WORK REQUIRED ARE SPECIFIED OR SHOWN. CONTRACTOR SHALL PROVIDE ALL ITEMS NEEDED TO HAVE COMPLETED 6. ELECTRICAL POWER: UNITS SHALL BE FOR USE WITH POWER AS SCHEDULED ON THE PLANS. THE PROPERLY OPERATING SYSTEMS. ITEMS PROVIDED SHALL BE OF COMMERCIAL / INSTITUTIONAL QUALITY RTU'S SHALL HAVE SINGLE SOURCE POWER ENTRY, AND SHALL REQUIRE ONLY ONE FIELD CONSISTENT WITH THE QUALITY OR RELATED ITEMS PROVIDED ON THE PROJECT OR CURRENTLY BEING CONNECTION AND POWER SOURCE (EXCEPT FOR SEPARATE POWER TO ECONOMIZER) ALL USED IN THE BUILDING. NECESSARY TERMINAL BLOCKS. FUSES, WIRING, JUNCTION BOXES, ETC. SHALL BE FACTORY INSTALLED WITHIN THE UNIT CABINET TO PROVIDE POWER TO ALL UNIT DEVICES REQUIRING POWER. 6. SEISMIC: ALL DUCTWORK AND EQUIPMENT SHALL BE INSTALLED AND BRACED FOR THE SEISMIC CATEGORY FOR THIS PROJECT PER CODE AND SMACNA "SEISMIC RESTRAINT MANUAL GUIDELINES FOR 7, START-UP: START-UP AND SUBSEQUENT SYSTEM CHECKS SHALL BE DONE FOLLOWING THE MECHANICAL SYSTEMS" LATEST EDITION AND PER CODE. BUILDING IS NON -ESSENTIAL, SEISMIC DESIGN MANUFACTURERS WRITTEN START-UP PROCEDURES PRIOR TO OPERATING UNITS. FIELD CHECKLISTS CATEGORY "D". SHALL BE MADE TO ENSURE THAT ALL EQUIPMENT, PIPING AND CONTROLS ARE CONNECTED AND OPERATING PROPERLY. (NON -APPLICABLE - EXISTING) (INFO ONLY) GREASEITYPE 1 HOOD EXHAUST FAN (ROOFTOP) (EXISTING) (VERIF. ONLY) DUCT SYSTEM MUA-1 (VERIFY ONLY) 1. QUALITY ASSURANCE: UNIT SHALL BE UL LISTED AND LABELED AS SUCH. UNIT EFFICIENCY SHALL COMPLY WITH ALL UP TO DATE AND APPLICABLE CODES. 1. GALVANIZED SHEETMETAL CONSTRUCTED AND INSTALLED PER SMACNA REQUIREMENTS. 2. EXHAUST FAN SERVING THE TYPE 1 HOOD SHALL BE GREASE RATED. 2. PROVIDE FLEX CONNECTORS ON ALL DUCT CONNECTIONS NECESSARY FOR ISOLATION OF AIR HANDLING EQUIPMENT (NEOPRENE COATED FIBERGLASS FABRIC). 3. FAN: FAN SHALL BE STATICALLY AND DYNAMICALLY BALANCED AT FACTORY. FAN SHALL BE FORWARD CURVE CENTRIFUGAL TYPE WITH MULTI -SPEED DIRECT DRIVE (OR BELT DRIVE) MOTOR. MOTOR SHALL BE CONTROLS PERMANENTLY LUBRICATED TYPE WITH BUILT-IN AUTO -RESET THERMAL OVERLOAD PROTECTION. BEARINGS SHALL BE SEALED, PERMANENTLY LUBRICATED BALL BEARING TYPE. THE GREASE RATED 1. MUA-1 & EF-1 SHALL BE INTERLOCKED, PER DRAWING NOTES, AS INDICATED ON THE REQUIRED EXHAUST FAN, SHALL BE STATICALLY AND DYNAMICALLY BALANCED AT FACTORY, INCLUDING THE SHEET(S) MAKE-UP AIR FAN (MUA-1) GENERAL INFORMATION ONLY & MAY NOT BE APPLICABLE DUCTWORK FOR MUA-1 1.1 ALL DUCT DIMENSIONS ON PLAN ARE CLEAR INSIDE DIMENSIONS, ADD 2" TO EACH DIMENSION TO OBTAIN OUTSIDE DIMENSION. ADD 4"TO EACH DIMENSION IF DUCTWORK IS ON THE EXTERIOR OF BUILDING. 1.2 THE FIRST NUMBER ON ALL DUCT DIMENSIONS IS THE WIDTH AND THE SECOND NUMBER IS THE HEIGHT. 1.3 MATERIALS WITHIN DUCTS OR PLENUMS SHALL HAVE A FLAME SPREAD RATING LESS THAN'25 AND A FLAME SMOKE DEVELOPMENT RATING LESS THAN 50, PER IMC 602.2.1. 1.4 SEAL ALL TRANSVERSE JOINTS FOR DUCTWORK WITH STATIC PRESSURE BETWEEN 1/2 INCHES AND 2 INCHES. DUCTWORK WHICH IS DESIGNED TO OPERATE AT PRESSURES ABOVE 1/2 INCH WATER COLUMN STATIC PRESSURE SHALL BE SEALED IN ACCORDANCE WITH STANDARD RS-7. 1.5 ALL DUCT GAUGES PER SMACNA, IMC 603-4. 1.6 ALL DUCT SUPPORTS PER SMACNA, IMC 603-10. 1.7 ATTACH DIFFUSERS AND GRILLES TO T-BAR GRID PER WA STATE & LOCAL CODES. 1.8 BALANCING DAMPERS ARE TO BE INSTALLED ON ALL BRANCH DUCTS OR DIFFUSERS. INSULATION FOR MUA SYSTEM 2.1 INSULATE OR LINE DUCTWORK PER WA. STATE ENERGY AND MECHANICAL CODES. 2.2 INSULATE REFRIGERANT & CONDENSATE PIPING PER STATE & LOCAL ENERGY CODES. GENERAL CONTRACTOR - INFO ONLY 3.1 GENERAL CONTRACTOR TO PROVIDE AND CUT OPENINGS FOR ALL ROOFTOP, CEILING, FLOOR, AND WALL PENETRATIONS, INCLUDING WEATHERPROOF SEALING AND FIRE PROOF LINING PER IMC & IBC. 3.2 GENERAL CONTRACTOR TO VERIFY PENETRATION LOCATION AND DIMENSIONS WITH ERL BEFORE FRAMING OPENINGS. 3.3 GENERAL CONTRACTOR TO PROVIDE ALL DEMOLITION, PATCHING, AND PAINTING AS REQUIRED FOR MECHANICAL WORK. 3.4 GENERAL CONTRACTOR TO PROVIDE ADEQUATE STRUCTURAL SUPPORT AS REQUIRED FOR MECHANICAL WORK. 3.5 GENERAL CONTRACTOR TO PROVIDE ADEQUATE ENGINEERING AS REQUIRED FOR MECHANICAL WORK. 3.6 GENERAL CONTRACTOR TO PROVIDE SERVICE ACCESS PER CODE TO ALL MECHANICAL EQUIPMENT. 3.7 GENERAL CONTRACTOR TO LEVEL ALL FACTORY CURBS PROVIDED BY ERL PROVIDE ALL CANT STRIPS AND CURB INSULATION, AND SEAL AGAINST LEAKS. 3.8 GENERAL CONTRACTOR TO PROVIDE ALL CUTTING AND PATCHING OF T-BAR CEILING AS REQUIRED FOR HVAC INSTALLATION. 3.9 GENERAL CONTRACTOR TO PROTECT ALL OPENINGS THROUGH FLOORS PROVIDED FOR DUCTWORK INSTALLATION IN ACCORDANCE WITH TABLE 601 OF INTERNATIONAL BUILDING CODE, WHERE REQUIRED BY SECTION 707 OF IBC. ELECTRICAL - BY OTHERS 4.1 ERL TO INSTALL ALL LOW VOLTAGE CONTROL WIRING, CONDUIT WILL BE PROVIDED BY ELECTRICAL CONTRACTOR. 4.2 ELECTRICAL CONTRACTOR TO PROVIDE ALL ELECTRICAL CONNECTIONS, DISCONNECTS, AND STARTERS FOR MECHANICAL EQUIPMENT. 4.3 ELECTRICAL CONTRACTOR TO VERIFY EQUIPMENT SIZES LOADS AND LOCATIONS WITH ERL MECHANICAL PLAN AND WITH FIELD CONDITIONS. 4.4 ELECTRICAL CONTRACTOR TO INTERLOCK BATHROOM EXHAUST FANS WITH LIGHT SWITCH. 4.5 ERL TO PROVIDE 7-DAY NIGHT SETBACK, PROGRAMMABLE TYPE T-STAT WITH CAPABILITY OF 5°F DEADBAND. 4.6 ERL TO VERIFY FINAL LOCATION OF THERMOSTAT WITH CUSTOMER. 4.7 ELECTRICAL CONTRACTOR TO PROVIDE ELECTRICAL GFCI OUTLET WITHIN 25 FT OF EACH PIECE OF MECHANICAL EQUIPMENT. PLUMBING - NOT IN THIS CONTRACT - BY OTHERS 5.1 PLUMBING CONTRACTOR TO FURNISH AND INSTALL ALL GAS PIPING FOR MECHANICAL EQUIPMENT PER CODE. 5.2 PLUMBINGCONTRACTOR OFFSET VENTS 10 FEET MINIMUM FROM ALL HVAC FRESH AIR INTAKES OR & ABOVE HIGHEST POINT OF INTAKE, IMC 401.4.1. 5.3 CONDENSATE DRAINS FROM RTU BY ERL TO DRAIN WITHIN 12" OF UNIT. CONDENSATE DRAINS FOR AIR HANDLERS BY PLUMBER. ENERGY CODE COMPLIANCE 6.1 THE SUPPLY HEATING AND COOLING ENERGY TO EACH ZONE SHALL BE CONTROLLED BY INDIVIDUAL THERMOSTATIC CONTROLS CAPABLE OF RESPONDING TO TEMPERATURE WITHIN THE ZONE. AT A MINIMUM, EACH FLOOR SHALL BE CONSIDERED AS A SEPARATE ZONE 6.2 OUTDOOR AIR SUPPLY, EXHAUST OPENINGS AND RELIEF OUTLETS SHALL BE PROVIDED WITH CLASS 1A MOTORIZED DAMPERS WHICH CLOSE AUTOMATICALLY WHEN THE SYSTEM IS OFF PER WSEC SECTION C403.2.4.3. MECHANICAL CODE COMPLIANCE 7.1 WHERE REQUIRED PROVIDE AUTOMATIC SHUTOFF ACTIVATED BY SMOKE DETECTORS IN EACH SYSTEM DELIVERING HEATING OR COOLING AIR IN EXCESS OF 2000 CFM. DETECTORS SHALL BE LOCATED IN THE MAIN RETURN AIR PER IMC 606. WA2015 TYPE 1 HOOD -SYSTEM NOTES & REQ UIRED Q D TESTS 1. THE TYPE 1 GREASE HOOD, SHALL HAVE THE HOOD END PANEL INSTALLED. END PANEL SHALL BE INSTALLED BY THE HOOD MANUFACTURER, CAPTIVE AIR AS REQUIRED. 2. THE TYPE 1 HOOD EXHAUST DUCT (E) (NIC) IN WALL, HAS BEEN INSTALLED BY OTHERS. NEW DUCT SHALL BE SUPPLIED BY CAPTIVE AIR AND IMC CODE COMPLIANT AS A MINIMUM. I.E., DUCT SHALL HAVE TWO LAYERS OF FIRE BLANKET INSTALLED, AS REQUIRED BY THE LOCAL AHJ. 3. THE TYPE 1 HOOD SYSTEM SHALL HAVE THE ANSUL FIRE SYSTEM INSTALLED PER MANUFACTURER'S GUIDELINES AND REQUIRED CODES OF IMC. INCLUDE A FIRE SUPPRESSION NOZZLE IN THE GREASE DUCT. 4. THE TYPE 1 HOOD GREASE DUCT SHALL INCLUDE CLEAN OUT DOORS AT EACH TURN IN THE DUCT, OR AT 20' INTERVALS (IF APPLICABLE) IN THE HORIZONTAL DUCT. 5. THE TYPE 1 HOOD GREASE DUCT SHALL BE CONSTRUCTED OF 16 GA. STEEL, OR 18 GA. OF STAINLESS STEEL, MINIMUM. OR APPROVED DUCT SUPPLIED BY THE MANUFACTURER IN COMPLIANCE AS STATED, AND THE 2015 IMC CODES. 6. THE GREASE DUCT SHALL BE TESTED PRIOR TO ANY CONCEALMENT BY THE CONTRACTOR. THE METHOD SHALL BE PER CODE BY THE AHJ. 7. THE TYPE ONE HOOD INSTALLATION SHALL INCLUDE A STAINLESS STEEL BACKSPASH PANEL, MINIMUM 20 GA., ATTACHED TO WALL INSTALL PER MANUFACTURER'S GUIDELINES. 8. THE TYPE 1 EXHAUST, FIELD CONNECT TO HOOD. DUCT TO BE CONTINUOUSLY WELDED FROM ITS BEGINNING TO THE ENTRY OF THE ROOFTOP EXHAUST FAN. THE DUCT SHALL BE FIRE WRAPPED TO MEET A 1 HOUR FIRE RESISTIVE ENCLOSURE. HORIZONTAL DUCT SHALL SLOPE AT %a" PER LINEAL FOOT, BACK TO HOOD. 9. GREASE DUCTS SHALL INCLUDE AN ANSUL FIRE SUPPRESSION NOZZLE IN DUCT. INSTALL PER MANUFACTURER'S GUIDELINES. 10. INSTALL ANSUL FIRE SUPPRESSION SYSTEM PULL STATION AT 40" AFF. LOCATE AUTOMAN CABINET NEAR THE CEILING. (FIRE SUPPRESSION SHALL BE BY SEPARATE PERMIT). 11. CEILING DIFFUSERS ADJACENT TO EXHAUST HOODS AIR FLOW TO BE DIRECTED AWAY FROM HOOD. 12. THE GENERAL ROOM AIR HANDLER AND / OR HEATING VENTILATION SYSTEM CONTROL SHALL BE CONNECTED TO THE TYPE 1 HOOD FIRE SYSTEM. WHEN THE HOOD FIRE SYSTEM (ANSUL) IS ACTIVATED THE EQUIPMENT (AIR HANDLER) WILL BE SHUT DOWN, AND A MOTORIZED ISOLATION DAMPER CLOSED, THAT IS CONNECTED TO THE TYPE 1 HOOD AIR SUPPLY DAMPERS. THE INTENT IS TO STOP AIRFLOW AT THE FIRE SOURCE / EVENT. 13. THE MECHANICAL MAKE-UP AIR SYSTEM SHALL BE AUTOMATICALLY INTERLOCKED AND CONTROLLED TO START AND STOP SIMULTANEOUSLY WITH THE EXHAUST SYSTEM PER 2015 IMC 508.1 14. OPERATION OF THE TYPE 1 HOOD SYSTEMS SHALL BE DESIGNED AND INSTALLED TO AUTOMATICALLY ACTIVATE THE EXHAUST FAN WHENEVER COOKING OPERATIONS OCCUR, THROUGH AN INTERLOCK WITH THE COOKING APPLIANCES, BY MEANS OF HEAT SENSOR OR BY MEANS OF OTHER APPROVED METHODS, PER 2015 IMC507.2.1.1 15. THE HOOD TOP IS DESIGNED FOR "0" CLEARANCE TO COMBUSTIBLE SURFACES. IT SHALL BE INSTALLED PER MANUFACTURER'S GUIDELINES. COMBUSTIBLES SHALL NOT INFRINGE ON THE AREA EMPLOYED BY THE MANUFACTURER TO MEET THIS REQUIREMENT. 16. THE SUPPLIED HOOD REQUIRES A 2 HR. RATED WALL WHERE IT MOUNTS ON THE BACK OF THE HOOD. TYPICALLY THE WALL HAS METAL STUDS AND 2 LAYERS OF 5/8" GYPSUM, TYPE "X" DRYWALL. THIS WALL SHALL MEET ALL REQUIREMENTS OF THE LOCAL AHU. TESTS: 1. IMC 507.16.1 CAPTURE AND CONTAINMENT TEST: THE PERMIT HOLDER SHALL VERIFY CAPTURE AND CONTAINMENT PERFORMANCE OF THE EXHAUST SYSTEM. THIS FIELD TEST SHALL BE CONDUCTED WITH ALL APPLIANCES UNDER THE HOOD AT OPERATING TEMPERATURES, WITH ALL SOURCES OF OUTDOOR AIR PROVIDING MAKE UP AIR FOR THE HOOD OPERATING AND ALL SOURCES OF RE -CIRCULATION AIR PROVIDING CONDITIONING FOR THE SPACE IN WHICH THE HOOD IS LOCATED AND OPERATING. CAPTURE AND CONTAINMENT SHALL BE VERIFIED VISUALLY BY OBSERVING SMOKE OR STEAM PRODUCED BYACTUAL OR SIMULATED COOKING. SIMULATED AS WITH SMOKE CANDLES, SMOKE PUFFERS, ETC. 2. IMC 506.3.2.5 GREASE DUCT TEST. A LIGHT TEST SHALL BE PERFORMED BY PASSING A LAMP HAVING A POWER RATING OF NOT LESS THAN 100 WATTS THROUGH THE ENTIRE SECTION OF DUCTWORK TO BE TESTED. THE LAMP SHALL BE OPEN SO AS TO EMIT LIGHT EQUALLY IN ALL DIRECTIONS PERPENDICULAR TO THE DUCT WALLS. A TEST SHALL BE PERFORMED FOR ALL THE ENTIRE DUCT SYSTEM INCLUDING THE HOOD TO DUCT CONNECTIONS. THE DUCT SYSTEM SHALL BE PERMITTED TO BE TESTED IN SECTIONS FOR LISTED FACTORY BUILT GREASE DUCTS. THIS TEST SHALL BE LIMITED TO DUCT JOINTS ASSEMBLED IN THE FIELD, AND SHALL EXCLUDE FACTORY WELDS. 3. IBC SECTION 904.12.1 MANUAL SYSTEM (FIRE) OPERATION. A MANUAL ACTIVATION DEVICE (PULL STATION SHALL BE LOCATED AT OR NEAR A MEANS OF EGRESS FROM THE COOKING AREA NOT LESS THAN 10 FEET, AND NOT MORE THAN 20 FEET FROM THE KITCHEN EXHAUST SYSTEM. THE MANUAL ACTUATION DEVICE SHALL BE INSTALLED NOT MORE THAN 48 INCHES OR LESS THAN 42 INCHES ABOVE THE FLOOR AND SHALL CLEARLY IDENTIFY THE HAZARD PROTECTED. THE MANUAL ACTUATION SHALL REQUIRE A MAXIMUM FORCE OF 40 LBS AND A MAXIMUM MOVEMENT OF 14 INCHES TO ACTIVATE THE FIRE SUPPRESSION SYSTEM. 4. FUEL PIPING SYSTEM - (NOT IN THIS SCOPE, BUT INSTALLED BY OTHERS) FUEL PIPING FOR EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE 2015 FUEL GAS CODE. THE LINE SIZING IS TO VALIDATED BY THE INSTALLATION FIRM OR CONTRACTOR. THE PIPING SHALL BE SUPPORTED IN COMPLIANCE WITH CODE, SECTION 407.2. SUPPORT WITH METAL STRAPS, HANGERS, HOOKS, ETC, AND SPACED PER TABLE 415.1 A) STEEL PIPE SIZE -'/2' DIA., SUPPORT 6 FT. O.C. B) STEEL PIPE SIZE - %TO V DIA. SUPPORT 8 FT. O.C. C) STEEL PIPE SIZE - 1-1/4" & LARGER: SUPPORT 10' O.C. D) ALL PIPING MATERIAL, SHALL BE IN COMPLIANCE WITH IFGC 404.4.2 STEEL AND WROUGHT IRON PIPE, SHALL BE SCHEDULE 40 AND COMPLY WITH ASTM A53 OR A106 5. HOOD MANUFACTURER SHALL BE RESPONSIBLE FOR THE SUPPORT METHOD OF THE TYPE 1 HOOD, AND INSTALLED BY THE CONTRACTOR. CONTRACTOR SHALL COORDINATE WITH THE HOOD MANUFACTURER FOR SPECIFIC SUPPORT AND SUSPENSION REQUIREMENTS, INCLUDING SEISMIC BRACING PER CODE. REVIEWED FOR CODE COMPLIANCE APPROVED AUG 2 8 2019 City of Tukwila BUILDING DIVISION K 5 m 7 • 10 RECEIVED CITY OF TUKWILA AUG 19 2019 Pi RM17' CENTER 10 PERMIT SET L 0 c O tow V a C Z_ O J uiC4d SW Cu o .- a E V a� ..... Z •�0 Q F - 0) �. < � J _>� oa F_W< C!) W > Wz� U) U CL v L.L.. 00 Uj W ao E- co W co W N z O U z Q W LLJ W U) 06 W p Z J p = U (A � _ ~ W U W J W w W O °- 0) d) H U z 0 W m z - z O U) U) I © 00 < 0 Z 0� (- w W V 2" SHEET SIZE IS TRUE SCALE WHEN ABOVE LINE MEASURES AS NOTED A I B I C I D I E I F I G H RENEW: 8/2021 J �I; FjA 0 C u A F W W J 13, 2 3 m 41 r 7 L1 • Vol 10 M1.OIM1.0 GREASE/EXIT EF MAKE-UP T (REF) (E) TYPE 1 HOOD WALLS (REF) KITCHEN HOOD EXHAUST SYSTEM REBALANCE CRITERIA EXISTING KITCHEN HOOD EXHAUST REQUIRED — 3025 CFM EXISTING EXHAUST FAN CFM EXHAUST --- 3025 CFM EXISTING MAKE UP AIR UNIT SUPPLY 2725 CFM EXISTING DUCWORK PRESSURE LOSS .75" SP NEW KITCHEN HOOD EXHAUST REQUIRED 3172 CFM NEW EXHAUST FAN CFM REQUIRED 3172 CFM NEW MAKE UP AIR REQUIRED 2854 CFM REVISION DUCT PRESURE LOSS INCREASE .20" SP KITCHEN EXHAUST REBALANCE REQUIREMENTS REBALANCE EXISTING HOOD EXHAUST FAN TO INCREASE THE AIR FLOW FROM 3025 CFM TO 3172 CFM REBALANCE EXISTING MAKEUP AIR UNIT SUPPLY AIR FROM 2725 CFM TO 2854 CFM PROVIDE NEW MOTOR, BELTS, PULLEYS ETC. REQUIRED TO PROVIDE NEW AIR FLOW QUANITIES CONSTRUCTION NOTES OFIELD MEASURED, EXISTING DUCT. HOWEVER, CONTRACTOR SHALL VERIFY EXACT LENGTH AS INDICATED. OVERIFY PROPER CONNECTION PER CODE TO (E) TYPE 1 HOOD AND DOCUMENT AS REQUIRED. O3 VERIFY EXISTING SLOPE, AND ADJUST TO SLOPE TO HOOD AS REQUIRED FOR GREASE DUCT TERMINATION AT HOOD. 4O INSTALL 12" X 12" ACCESS PANEL IN ACCORDANCE PER 2015 IMC CODES. SEE CODE REQUIREMENTS THIS DRAWING. �5 PROVIDE NEW GREASE RESERVOIR PER APPLICABLE CODES STATED ON THIS SHEET, IN THE EXISTING GREASE DUCT. RESERVOIR SHALL BE 12" WIDE BY 20" (WIDTH OF DUCT), AND THE BOTTOM SHALL BE 1" BELOW THE BOTTOM OF THE EXISTING DUCT RESERVOIR AND SHALL SLOPE TO A 1-1/2" DRAIN OPENING WITH A DRAIN VALVE (LABELED AS REQUIRED) . THE RESERVOIR SHALL BE LOCATED ADJACENT TO THE ACCESS PANEL / DOOR. INSTALL 1-1/2" DIAMETER COPPER OR COMPATIB LE MATERIAL PIPING (IF COPPER WITH DIELECTRIC COUPLING) , FROM THIS LOW POINT, TERMINATING TO THE GREASE INTERCEPTOR OR APPROVED DRAIN. PROVIDE NECESSARY VENT FOR PIPING AS REQUIRED FOR PROPER DRAIN. O6 ENSURE PROPER SUPPORTS FOR BOTH GREASE AND MAKE UP AIR DUCT THAT IS IN COMPLIANCE WITH SMACNA STANDARDS. SEISMIC BRACE AS REQUIRED PER SEISMIC "D" REQUIREMENTS. SEE DETAIL 1 , THIS DRAWINGS AS A GUIDE. ANY PORTION OF INSULATION DISTURBED DURING CONSTRUCTION MUST BE MATCHED TO EXISTING, AND PROVIDE PROPER SEPARATION PER CODE(S) K 3 4 2015 INTERNATIONAL MECHANICAL CODE (IMC) 1� ALL WORK DESCRIBED HEREIN SHALL BE IN ACCORDANCE WITH SECTION 506, COMMERCIAL KITCHEN HOOD VENTILATION, SYSTEM DUCTS, AND EXHAUST EQUIPMENT. 2O GREASE DUCT SHALL BE CONSTRUCTED (EXISTING) IN COMPLIANCE WITH 506.3.1.1 MATERIALS. O3 ALL EXISTING MAKE-UP AIR DUCT SHALL BE IN COMPLIANCE TO IMC 506.3.1.2 Jr 4� GREASE DUCT CONFIGURATION SHALL BE IN ACCORDANCE WITH IMC 506.3.7 & 506.3.7.1, GREASE DUCT RESERVOIRS ITEMS 1 THRU 7. 5� ALL GREASE DUCT CLEANOUTS AND OPENINGS SHALL BE IN ACCORDANCE WITH IMC 506.3.8 ITEMS 1 THRU 7. OGREASE DUCT HORIZONTAL CLEANOUTS SHALL BE INSTALLED IN COMPLIANCE WITH IMC 506.3.9 SPACING SHALL NOT BE MORE THAN 20 FT. APART. BE LOCATED NOT MORE THAN 10 FEET FROM CHANGES IN DIRECTION THAT ARE GREATER THAN 45 DEGREES. CLEANOUTS SHALL BE LOCATED AND INSTALLED ON THE BOTTOM OF THE 6 GREASE DUCT ONLY, AND SHALL BE PROVIDED WITH INTERNAL DAMMING OF THE OPENING SUCH THAT GREASE WILL FLOW PAST THE OPENING WITHOUT POOLING. BOTTOM CLEANOUTS AND OPENINGS SHALL BE APPROVED FOR THE APPLICATION AND INSTALLED LIQUID TIGHT. SHALL BE LOCATED AT GREASE RESERVOIRS. UNISTRUT LAG BOLT TO CELING (TYP) 3/8" 0 THREADED ROD DOUBLE NUTS WITH WASHERS 16 GAUGE 1 3/4" GALV STEEL BAh DUCT 3/16" fly FLAT BAR BENT USE 3/8" DIA THREADED ROD (DIAGONAL) TO PREVENT LATERAL MOVEMENT (ON 30" CENTERS) ►UGE RIVETS (TYP) NOTE: CONTRACTOR RESPONSIBLE TO SIZE ANCHOR BOLTS & EMBED DEPTH & TO SELECT TYPE & STYLE TO SUITE BLDG CONSTRUCTION. PLAN VIEW - GREASE EXHAUST & MUA DUCT RUN DUCT HANGER/SEISMIC BRACING CI G SCALE: 1/4" / LF & AS MARKED NORTH DETAIL- ROUND O R RECTANGLE DUCT NO SCALE C 10 F ■ 0 I RENEW: 8/2021 J REVIEWED FOR CODE COMPLIANCE APPROVED AUG 28 2019 City of Tukwila BUILDING DIVISION 0 Fool E RECEIVED CITY OF TUKWILA AUG 19 2019 PERMIT CENTER 10 PERMIT SET N O 0 _j j g C6 dUj z'yF..N =0wt 0v)zWF- W W W m J 2aYoa L Cc bmw u slow � N 3 W ,amo: d W N _j am 9 E 0 ....: U) Z • _/ 0 0 < o Q o • — °' -j WLL m -j W F_MQ C� W > �z U) U tL a 0ry � r� U==I W � O Qor- LL W w g00 N Iti cA o z ' W U W w Z z W U CL _ U 0 U °- p z W U Z rn w a, in m U 00 Z a. _ ¢ o U) o o IL W p=, 11. 2" SHEET SIZE IS TRUE SCALE WHEN ABOVE LINE MEASURES AS NOTED I K 3 0 5 rol 1001 9 10 (E) NIC WORK - MOE AREA TO (E) ROOFTOP EQUIP. PREVIOUSLY INSTALLED BY OTHERS NIC ELEVATION SCALE: FIELD MEASURE /M CI I00n0 r QVCTCftA /TVA \ ELEVATION SCALE: FIELD MEASURE M1.11M1.0 M1.11M1.0 T, 3LE) L (E) 24" O 1 (TYP.) 2 5 25'-6" (E) GREASE L O DUCT . 0 co (E) FLOOR ELEVATION ELEVATION SCALE: FIELD MEASURE (E) MUA DUCT (REF) (E) T HOOD ELEVATION SCALE: FIELD MEASURE A 1 M rl r%1 A M1.11M1.0 AIRFLOW n M1.11M1.0 H I i I K CONSTRUCTION MOTES 1� 12" x 12" ACCESS PANEL INSTALLED ON BOTTOM OF DUCT. SEE DWG. M1.0 1 OSEE DWG. M0.0 SPECIFICATIONS FOR SLOPE REQUIREMENTS. START FROM HIGH POINT (ADJUST AS REQUIRED) TO LOW POINT, AT LENGTH SHOWN AND FIELD VERIFIED. OENSURE AFTER HEIGHT ADJUSTMENTS OF DUCT THAT PROPER SUPPORTS ARE MAINTAINED OR NEW INSTALLED AS REQUIRED. SEE SMACNA STANDARDS FOR PROPER SPACING (8'-0") UNLESS OTHERWISE SPECIFIED 4) WHERE INSULATION IS DISTURBED AS THE RESULT OF DUCT HEIGHT ADJUSTMENT, CONTRACTOR SHALL REPLACE INSULATION AT DISTURBED 2 AREA TO MATCH EXISTING FIRE RATED INSULATION. O5 SEE DRAWING M1.0 AND NOTE #5 FOR RESERVOIR DRAIN CRITERIA AND REQUIREMENTS PER 2015 IMC CODE(S). A I B ( I D � E I � I RENEW: s/aoai C G I H FREVIEWED FOR MPLIANCE OVED AUG2 8 2619 City of Tukwila BUILDING DIVISION 4 5 6 m• 9 RECEIVED CITE` OF TUKWILA AUG 19 2019 10 PERMIT CENTER PERMIT SET L 0 V p J $�Y ~z ©C C!) W ry W W U) W > 2Wz� U� U � a O �o� W W � � cn 00 Ito W W W >- F-- 06 a� ti p Q z > o rn J --� � U lJ.l W U) d OC w t— 0 a= 0 2 06 � 0 U W W z� W 0 O �' o, p U m Li z 2 o cn W 0 H _ z 0 W 0. . cn a W NOTE: LOCATION OF DRIVEWAYS, PARKING, LOADING AND SERVICES AREAS REMAIN UNCHANGED. LANDSCAPING AND IRRIGATION REMAIN UNCHANGED. I'CONTRACTOR SHALL PROVIDE MALL FACILITIES 48-HOUR ADVANCE NOTICE PRIOR TO DEMOLITION. 2.CARESHALL BE TAKEN DURING DEMOLITION SO AS NOT TO DAMAGE OR ALTER ANY EXISTING STRUCTURAL MEMBERS. LANDLORD SHALL BE NOTIFIED .IMMEDIATELY IF ANY DAMAGE OCCURS OR IS DISCLOSED. DURING DEMOLITION. 3.ALL WALLS AND CEILINGS THAT ARE REMOVED, THE CONTRACTOR SHALL BE RESPONSIBLE FOR DISCONNECTING AT THE SOURCE AND REMOVING OR CAPPING ANY ELECTRICAL, PLUMBING, GAS LINES AND MECHANICAL DUCTWORK THAT IS DISCLOSED AND NOT SCHEDULED FOR REUSE. REROUTE AND CONTINUE ANY SYSTEM THAT MUST BE RETAINED FOR ADJACENT TENANT SPACES THAT ARE NOT IN THESE PLANS. 4:ALL ELECTRICAL CIRCUITS FOR EQUIPMENT THAT IS TO BE REMOVED SHALL BE DISCONNECTED AT SOURCE AND REMOVED. 5.ALL GAS WATER AND DRAIN LINES SUPPLYING EQUIPMENT THAT IS TO BE REMOVED SHALL BE DISCONNECTED, REMOVED AND CAPPED ABOVE CEILING OR BELOW FLOOR. IF CONTINUITYF OF SYSTEM MUST BE MAINTAINED FOR USE BY ADJACENT TENANT SPACES, CONTRACTOR SHALL REROUTE, AS NECESSARY, TO BE BEHIND NEW CONSTRUCTION. B.CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVING FROM SITE, ALL RUBBLE AND DEBRIS CAUSED BY DEMOLITION AND DISPOSING OF IT IN A PROPER MANNER. PROVIDE HAUL ROUTE TO MALL MANAGEMENT FOR REMOVAL OF RUBBLE OR DEBRIS. PROTECT MALL FLOOR WITH MASONiTE OR SIMILAR WHEN USING CARTS, DOLLIES OR OTHER TRANSPORTATION METHODS. DEBRIS REMOVAL MUST NOT BE VISIBLE IN THE MALL COMMON AREA BUSINESS DAYS IN ADVANCE. SPRINKLER DRAIN )N MEETING. 9.PROTECT ANY VENTS, VERIFY WITH MALL FACILITIES PRIOR TO COVERING RETURN VENTS. 10_SPRINKLERAND RESTORATION COMPANY MUST BE ON STANDBY DURING DEMOLITION. 11.PROTECT MALL FINISHES- PATCHBACK AS NECESSARY. CONTACT FACILITIES FOR MALL TILES. REFER TO CONSTRUCTION MANUAL FOR CEILING AND NEUTRAL PIER PAINT SPEC. 12-GC TO CONDUCT DEMOLITION WALK-THROUGH WITH TC AND MALL FACILITIES PRIOR TO ANY NEW WORK. COORDINATE CEILING ACCESS PANEL LOCATIONS WITH MALL FACILITIES PRIOR TO INSTALLING NEW CEILING. DESIGN AND TECHNICAL CRITERIA PY FROM LANDLORD'$ TENANT 0.TION SHALL APPLY. TO PERFORM A SITE SURVEY OF THE ENTIRE PREMISES PRIOR TO COMMENCEMENT OF ON. ANY VARIANCES BETWEEN THESE APPROVED PLANS; LANDLORD PROVIDED LOP AND NS SHALL BE THE SOLE RESPONSIBILITY OF THE TENANT. ALL COSTS ASSOCIATEDWITH EORDERS :SHALL BE THE SOLE RESPONSIBILITY OF TENANT. ) TO CONDUCT A PRECONSTRUCTION MEETING AT A MINIMUM 3 DAYS PRIOR TO START OF ACILiTIES MANAGER AND ABIDE BY ALL CURRENT'TENANTCONTRACTOR SAFETY 4N'f CONSTRUCTION RULES AND REGULATIONS AS ISSUED BY THE LOCAL CENTER i REQUIRED TO BE INSTALLED WITHIN 48 HOURS OF BARRICADE INSTALLATION. GRAPHICS 'DISTRICT MARKETING MANAGER ELISSA COTERO (ELISSACOTERO@URW.COM 206.802-6048) ) TO PROVIDE ONE FINAL SET OF DRAWINGS CONTAINING ALL COMMENTS INCLUDING ENANTAS WELL AS WESTFIELD TC APPROVAL STAMP AND CITY PERMIT STAMP AT iETING AND MAINTAINED AT WORK SITE AT ALL TIMES. ON ACCESS, AS REQ'D, TO ALL UTILITY SYSTEMS SERVING THE BASE BUILDING OR ADJACENT EUSED ITEMSIFIN1SHES MUST BE RETURNED TO LIKE NEW CONDITION. APPROVAL BY WESTFIELD REQUIRED. )DITIONAL SiGNAGE, GRAPHICS OR MERCHANDISE FIXTURES ARE PERMITTED TO BE AFFIXED TO OR ON THE JED DESIGN, DISPLAYED OUTSIDE OF THE PREMISES OR PLACED WITHIN OR ON TOP OF COUNTERS AND :GUARDS WITHOUT THE EXPRESS WRITTEN CONSENT OF THE LANDLORD. ALL LANDLORD APPROVED 7E; PROMOTIONAL OR OTHERWISE, SHALL SE PROFESSIONALLY PRINTED AND MOUNTED. FIELD TC APPROVAL REQUIRED PRIOR TO BARRICADE TAKE DOWN. TENANT GC TO SCHEDULE PRELIMINARY WALK WITH WESTFIELD TC ONE WEEK PRIOR TO SCHEDULED BARRICADE TAKEDOWN. L All concepts, designs, arrangements, and data Indicated on these documents are the property of G. A. Miller Architecture and were created, evolved, and developed for use on, and in connection with the specified project. None of such Ideas, designs, arrangements, or data shall be used by, or disclosed to File: 1801-13 ALI Site Plan - Demo Plan Exit Pian.dwg Date/Time: January 11, 2019 5:05 PM Scale: i=48 Xrefs: any person, firm, or corporation for any purpose whatsoever without permission of G. A. Miller Architecture, NOTE: G.C. IS RESPONSIBLE FOR FIELD VERIFYING ALL DIMENSIONS, COLUMN LOCATIONS, AND CONDITIONS PROOR TO ANY WORK NOTIFY ARCHITECT OF ANY CONFLICTS PROOR TO ANY WORK FOR DIRECTION. DEMO. PLAN LEGEND EXISTING WALL OR PARTITION TO REMAIN EXISTING STOREFRONT TO REMAIN EXISTING STOREFRONT TO BE REMOVED EXISTING DOOR TO REMAIN r� I � EXISTING DOOR TO REMAIN DEMOLITION PLAN GENERAL NOTES I. REMOVE AND DISPOSE OF ALL EXISTING FLOORING AND BASE U.ON. 2. PROTECT ALL ADJACENT AREAS DURING DEMOLITION FROM DUST 4 TRASH INTRUSION. 3. VERIFY WITH OW ER RE -USE OR SALVAGE OF ALL FURNITURE, FIXTURES, 4 EQUIP. PRIOR TO DEMOLITION WORK REVIEW ON SITE IF POSSIBLE. 4, IT IS THE GENERAL CONTRACTOR'S RESPONSIBILITY TO VISIT THE SITE AND CONFIRM ALL EXISTING CONDITIONS AND VERIFY ALL WORK SCHEDULED FOR DEMOLITION OR TO REMAIN, AND NOTIFY THE ARCHITECT OF ANY CONFLICTS OR DISCREPANCIES PRIOR TO COMMENCING WITH ANY WORK 5. VERIFY ALL UTILITY CONNECTIONS AND LOCATIONS PRIOR TO ANY DEMOLITION WORK 9,. DO NOT DEMO OR REMOVE ANY EXISTING ELECTRICAL PANELS, TRANS- FORMERS, FIRE PANELS, OR EMERGENCY LIGHTING U.ON. 1. CONTRACTOR SHALL VERIFY FIELD CONDITIONS AND MAKE ADJUSTMENTS AT NO ADDITIONAL COST TO THE OWNER 2. ALL WORK SHALL BE COMPLETED IN ACCORDANCE WITH ALL APPLICABLE JURIS- DICTION AND LOCAL CODES. 3. PROVIDE ACCESS PANELS AS NEEDED TO ACCESS VALVES, EQUIPMENT, ETC. LOCATED ABOVE GYP. BD. OR OTHER INACCESSIBLE CEILINGS. 4. PROVIDE CLEAN -OUTS AS NEEDED TO ACCESS SANITARY SEWER LINES, ETC. LOCATED AS VERIFIED IN FIELD 5. REFER TO PLUMBING DRAWINGS FOR ADDITIONAL NOTES, SPECS., 4 INFO. REVIEWED FOR CODE COMPLIANCE APPROVED City of Tukwila BUILDING DIVISION CITY OF `i i KN11► A A iviA AF Cr]I JI i� ,C .N UAP, J J J J J J J J J J J J J 141 DEL PRADO LAKE OSWEGO, OREGON 97035 503.636.7979 503.636.9898 - FAX g lenagamil lerarchitecture.com CONSULTANTS MATHEWS CONSULTING GET&RAL CONTRACTOR EM PRECISION PUYALLUP, WASHINGTON REGISTERED T ART - ME A. STATE OF WASNIE14 M TRAPPER'S SUSHI T.I. SOUTHCENTER MALL TUKWILA, WASHINGTON J J J J J J J J J J J J J OWNER - TRAPPER'S SUSHI CO. AS' 10 (/r ~' I 1-11-19 1L.L. COMMENTS - ADDEND. 01 12-14-I5 L.L. REVIEW MARKI DATE I DESCRIPTION JOB NO.: 1807-13 FILE: 1807-13 Al-1 BY: PLAN CHECK NO. PERMIT NO. DATE: DECEMBER 14, 2018 ® copyright 2013 GA MILLER ARCHITECTURE SHEET TITLE SITE PLAN, DEMO. PLAN, EXIT DISCHARGE DWG. m SHEET OF LEGEND EGRESS E W TRAVEL. SEE EGRESS NOT"2 BELOW. ■ ■ ■ ®®®■ s .0 EGRESS EXIT PATH EMERGENCY / EXIT COMBO LIGHT FIXTURE - NEW OR EXIST'G. SEE EGRESS NOTE » 2 AND R.C.P. (TYP.) NEW OR EXISTING (VERIFY) TACTILE ES EXIT SIGN PICTOGRAM IN ACCORD- ANCE WITH [CC ANSI AI11.1 SECTION 103 CODE OCCUPANCY: I. SEE COVER SHEET FOR PROJECT AREAS AND TOTAL OCCUPANCY. 2. OCCUPANCY GROUP: A-2, RESTAURANT 1. THE TENANT SPACE CURRENTLY HAS FIRE SPRINKLER 0 PROTECTION. THE CONTRACTOR SHALL MODIFY AS NEEDED TO ACCOMODATE THE NEW DESIGN LAYOUT TO CONFORM WITH NFPA 13 SPRINKLER REQUIREMENTS. 2, POST MAX. OCCUPANT LOAD SIGNAGE INSIDE THE FRONT DOOR WITH A PERMANENT SIGN IN ACCORDANCE WITH STATE AND LOCAL CODES AND REQUIREMENTS. 3. REFER TO LIGHTING PLAN, REFLECTED CEILING PLAN, AND LIGHT FXTURE SCHEDULES FOR ADDITIONAL LOCA- TIONS OF EXIT LIGHTS, EMERGENCY LIGHTING NOTES, AND SPECIFICATIONS. EGRESS NOTES I. IF NOT EXISTING, PROVIDE AN EMERGENCY ELECTRICAL SYSTEM THAT SHALL AUTOMATICALLY ILLUMINATE EXTERIOR LANDINGS FOR EXiT DOORWAYS AND EXIT PASSAGEWAYS IN ACCORDANCE WITH IBC SECTION 1008. PROVIDE I F.G. N MiN. AT LANDING AND FLOOR SURFACES, THE SYSTEM OR u FIXTURE SHALL PROVIDE POWER FOR A DURATION OF w NOT LESS THAN 90 MINUTES AND SHALL CONSIST OF ? STORAGE BATTERIES OR UNIT EQUIPMENT. THE INSTALL- p ATION OF THE EMERGENCY POWER SYSTEM SHALL BE w IN ACCORDANCE WITH IBC SECTION 2102. THE FIXTURES MUST BE UI I. RATED FOR DAMP LOCATIONS ` 2. PROVIDE I F.C. MIN. ILLUMINATION AT EGRESS PATH OF TRAVEL AS SHOWN! AND AT EXIT DOORS. SEE LIGHT 0 FIXTURE SCHEDULES FOR EMERGENCY/EXiT FIXTURE SPECIFICATIONS. 3. SEE LIGHTING PLAN d SCHEDULE FOR NEW OR EXISTING LIGHTING ON SEPARATE CIRCUIT AND SEPARATE BATTERY/ INVERTER SYSTEM FOR EGRESS LIGHTING. i SAFETY l AL2 I/4"=t XREF(5):1801-13 BASE File: 1801-13 AI2 Life Safety -Egress Piandwg DateMme: January 10, 20113 4:52 PM Scale: i=48 Xrefs: 2 KtPI( Z z O W J x Z O Z Of o O W O O t- V IW- _ U) W Z WO LL d' z z H 0 0 W wLU U) TO EXISTING STORAGE IF TT EXISTING OFFICE I A II LL BACK -OF -HOUSE ` l' moo; ------- MEN DINING 90■00■■00■0■00■00'■00■■■6 m m m m E3 ■ �000■0■00. v v m \ II � II ■ / II ■ ESUSHI lil KITCHEN L t° o A � r- , I L-1 i I� 11= 'IU) IU) r` I Pffi ,= 1 I � I i 11� II II I �r—®----------I WOMEN OH LOCKED LIQUOR STORAGE ce v III � U_' QL_ t- _V LIQUOR BAR®®®■■■■■■®®®®5 IL 4 - - - - - - - - E] ■ m m DINING m m v �# 1 NOT A FIRE EXIT -OUTDOOR PATIO pINING� ■ -- ------------ m ■■% v ■ lip E T3 1:3 1:3 v ■ ■ ■ m m v ■ v ■ m ■ m ■ Ur I ■ m Z. ® DINING ® Z -------' m ■ C] -------� m v W IE m IE v t- --------1I m m Z ®TJ E ■ O m ■ U i v m -------- IE 1 ■ i m m I SEE NOTE • i THIS SHEET TC REVIE CODE C APF APR City C BUILDIN U_�E= MM - 11 0� All concepts, designs, arrangements, and data Indicated on these documents are the property of G. A. Miller Architecture and were created, evolved, and developed for use on, and in connection with the specified project. None of such Ideas, designs, arrangements, or data shall be used by, or disclosed to any person, firm, or corporation for any purpose whatsoever without permission of G. A. Miller Architecture. h J J JJJ J J J J J J J J 141 DEL PRADO LAKE OSWEGO, OREGON 97035 503.636.7979 503.636.9898 - FAX g lenagami I lerarchltecture.com CONSULTANTS MATHEWS CONSULTING GENERAL CONTRACTOR EM PRECISION PUYALLUP, WASHINGTON ff"' RfG157fRfD ARC{ jiTT LEN�MI�LtERL STATE Of l'lA3kIMOTON TRAPPER'S SUSHI T.I. SOUTHCENTER MALL TUKWILA, WASHINGTON J J J J J J J J J J J J J OWNER - TRAPPER'S CO. gS�USHI AP� M� f►0 4 SU 141 ca 12-14-IS LL. REVIEW MARK DATE DESCRIPTION JOB NO.: 1807-13 FILE: 1807-13 Al-2 BY: PLAN CHECK NO. PERMIT NO. DATE: DECEMBER 14, 2018 © copyright 2013 GA MILLER ARCHITECTURE E PLI AFETY 1 EGRESS PLAN 2019 PtECIVED CITY OF WKWILA ukwila APR 17 2019 DIVISION CENTER A2 ■ SHEET OF REMOVE EXIST'G, STOREFRONT GLAZING 4 MULLIONS, INSTALL NEW 3'-O'x1'-O' ALUM. STOREFRONT DOOR (MATCH EXISTING DRS.) 4 INSTALL NEW TEMPERED GLAZING EA. SIDE OF DOOR SEE DOOR SCHEDULE AND SPECS. SEE COVERSHEET 4 DR. SCHEDULE FOR ENERGY CODE SPECS. REMOVE EXISTING STOREFRONT AND ENTRY DOORS 4 RE -USE IF POSSIBLE AT NEW LOCATION SHOWN ON 2 PLANS. INSTALL NEW STOREFRONT WINDOW SYSTEM IN ALIGNMENT WITH EXISTING STOREFRONT AS SHOWN, MATCH ADJACE GLAZING TYPE. ALL NEW GLAZING SHALL BE TEMPERED. EXISTING AAA. COMPLIANT RESTROOM 4 ACCE55ORIES TO REMAIN, SEE M-F DWG$. FOR NEW FINISHES. ® EXISTING BABY -CHANGING STATION TO REMAIN EXISTING COLUMN / COLUMN WRAP TO REMAIN. SEE M-F DWGS. FOR NEW FINISHES, TYP. REPLACE EXISTING STOREFRONT GLASS PANEL © WITH TEMPERED GLASS (THIS SECTION), IF NOT ALREADY TEMPERED (FIELD VERIFY) HOSTESS STATION, SERVER STATIONS, BANQUETTE ❑7 DESIGN, MILLWORK, AND CASEWORK DESIGN 4 DETAILING BY OTHERS. REFER TO M-F DRAWINGS. ® EXISTING ELECTRICAL PANELS - SEE ELECT'L. DWGS. Q EXISTING TRANSFORMER - SEE ELECT'L. DWGS. 10 EXISTING SIEMENS 'LP -28' PANEL - SEE ELECT'L. DWGS. it 42' HIGH PONY WALL W/ 12' WIRE MESH FRAME ATOP. SEE MF Duw. 12 68' HIGH PONY WALL W! 24- FROSTS GLASS ATOP, SEE t-F OW35. 13 55' HIGH PONY WALL W/ 12' WIRE MESH FRAME ATOP. SEE t-F Dur.S. 14 FRAME/FINISH 2- GAP BTWN. COOLER 4 (E) DEM. WALL GENERAL CONTRACTOR NOTES 1. THE G.C. SHALL VERIFY AND REFER TO DESIGNER (M-F) DRAWINGS FOR ALL DECOR, ARTWORK, MILLWORK, BAR DIE FURNITURE, ETC. PRIOR TO COMMENCING ANY WORK REFER TO M-F DRAWINGS FOR FRE. DIMENSIONS, AND NOTIFY THE ARCHITECT AND DESIGNER OF ANY CONFLICTS PRIOR TO COMMENCING WITH ANY WORK 2. VERIFY ALL SPEAKER AND LOW VOLTAGE EQUIPMENT 4 LOCATIONS, POWER REQUIREMENTS, ETC. WITH OWNER PRIOR TO ANY WORK 3. REFER TO THE COVER SHEET FOR ADDITIONAL GENERAL NOTES INCLUDING NOTES ON FIRE EXTINGUISHERS. 4. REFER TO M-F DWG5. FOR ALL FURNITURE 4 FINISHES U.ON. 5. G.G. SHALL VERIFY ANY AND ALL NEW ELECJDATA OUT- LET LOCATIONS IN FIELD WITH TENANT PRIOR TO BID. HEALTH DEPARTMENT NOTES 1. HEALTH DEPARTMENT INSPECTION 15 REQUIRED PRIOR TO OPENING. 2. NO CHANGES SHALL BE MADE WITHOUT WRITTEN APPROVAL FROM THE LOCAL HEALTH DEPARTMENT. 3. REFER TO KITCHEN EQUIPMENT DRAWINGS FOR ALL NEW FLOOR DRAIN AND IA. LOCATIONS 6 2 0 2 E3 E_B E-:n DINING 104 (E OFFICE E E3 :1 103 II A II 1- T NEW HAND SINK - SEE KEC DWGS. FOR EXACT LOCATION 4 SPECS.- 4 A3.1 E m� J u (E) BACK -OF -HOUSE 101 7YP. 3 � A3.1 r 1 MGM A3.1 3 A3.1 EXIST'G, WALLS TO REMAIN > a+ (E) COMMON EXIT CORRIDOR�� 100 4® Gi^� 1"6I' _ 1/4"=1'-O" XREF(W:1801-13 BABE File: I501-13 A2.1 Floor Plan.dwg Date/Time: January 11, 2015 5:00 PM Scale: 1=48 Xrefs: EXIT CORRIDOR 116 (E) MEN 114 El q■ o q:l 1�1 i ---------------- J" (E) ALCOVE20 P. 115-cc 112 I- - 0 ENSURE THAT WATERPROOF MEMBRANE IS INTACT - PERFORM TESTING TO CONFIRM iN EXISTING KITCHEN ~$ Ady A%V)NW,KXISTING TILE TO REMAIN. NOTE: VERIFY ALL DIMENSIONS W/ DESIGNER 41 °H REFER TO M-F DRAWINGS FOR ADDITIONAL DIMENSIONS FOR FF. d E. STORAGE 106 i'I'-W - VERIFY 3'-9 3/4 4' - W.F. PROVIDE V AIR SPACE BETWN. WALL 4 1-_ A3.1 t0 BEER COOLER 9 m � A3.1 A3.1 ------------ N _ 3 _- A3.1 - NOTE: COOLER WILL BE SUPPLIED 11 / 11 / I / \ L I- g05 W/ A PLYW'D. SURFACE. SEE KEC d DESIGN DWGS. REFER TO KITCHEN EQUIP, DWGS. FOR LiQUOR SPECS, ..............._....----------- -- --------- - B -------- _ I II I -- I --- -- - -- A3.1 16'-1 1/4' DINING 107 0 w NOTE: REFER TO SHT. Al2 OR EGRESS PATH OF TRAVEL 8 8 A3. 12 VERIFY I m PROVIDE SHOP DU.GS, PRIOR TO FAA MOGA� OR DESIGNER/ KECq \ ° - 8 O A3.1 j .4 I J WOMENJ /-------' D 115 �0�/ �- -- ------ i - ------- I X-1 '-------4'-O' i SERVER SIN. - - - - - - -- DINING 111 ------ tto i - - - - - - 5'-3l4't 1'-2' V-2I'-2' 4'- REFER TO KITCHEN EQUIP. DWGS. FOR SERVER EQUIP. -Il j------ 8 i o — > A3.1 S i , 1 g L A3 8 12 y A3.1 HOf STN 1 SUBMIT PATIO FURNITURE AND PATIO FENCING FOR LANDLORD APPROVAL ENTRY 108 REFER TO M-F D FOR INTERIOR ELEVATIONS, SCRE N WALL DETAILS, FINISHES, ETC.- COUNTER DINING \ 109 J\ 2 8 A3.1 REVIEW CODE CO -, APPA \j APR 2 4 _O, City Of BUILDING All concepts, designs, arrangements, and data indicated on these documents are the property of G. A. Miller Architecture and were created, evolved, and developed for use on, and in connection with the specified project. None of such ideas, designs, arrangements, or data shall be used by, or disclosed to any person, firm, or corporation for any purpose whatsoever without permission of G. A. Miller Architecture. A PALI L!A J J J J J J J J J J J J J 141 DEL PRADO LAKE OSWEGO, OREGON 97035 503.636.7979 603.636.9898 - FAX g lenogomi I lerorchitecture.com CONSULTANTS MATHEWS CONSULTING GENERAL CONTRACTOR EM PRECISION PUYALLUP, WASHINGTON ',g�6r14 REGISTE `'*A'RICHITjTI MF YtASH14iSi0N. TRAPPER'S SUSHI T.I. SOUTHCENTER MALL TUKWILA, WASHINGTON J J J J J J J J J J J J J OWNER - TRAPPER'S SUSHI CO. �// �1 t« too SUSHI Ca I-II-19 LL. COMMENTS -ADDEND. -1 12-14-18 L.L. REVIEW MARKI DATE I DESCRIPTION JOB NO.: 1807-13 FILE: 1807-13 A2-1 BY: PLAN CHECK NO. PERMIT NO. DATE: DECEMBER 14, 2018 0 copyright 2015 GA MILLER ARCHITECTURE TLE VE®NcE 2019 kwila iVISION OOR PLAN RECF1V' CITY or- i UK" A?R 17 201 Az SHEET OF ,LA MR REFLECTED CEIL'G. PLAN NOTES: 1. ARRANGE EMERGENCY LIGHT FIXTURES TO PROVIDE INITIAL ILL- UMINATION THAT IS AT LEAST AN AVERAGE OF ONE FOOT-CANDLE MEASURED ALONG THE PATH OF EGRESS AT FLOOR LEVEL. NIGHT LIGHTS SHOWN SHALL BE DESIGNATED AS EMERGENCY LIGHT FIXTURES, ADD ADDITIONAL EMERGENCY LIGHT FIXTURES IF NEC- ESSARY (VERIFY IN FIELD). EMERGENCY FIXTURES SHALL BE EQUIP- PED WITH AN EMERGENCY POWER SYSTEM THAT PROVIDES POWER FOR A MIN. OF 90 MINUTES, CONSISTING OF BATTERIES, UNIT EQUIP- MENT, OR AN ON SITE GENERATOR PER STATE CODES AND IBC SEC. 1006 2. CONTRACTOR TO LOCATE HVAC DIFFUSERS, RETURNS, t SPRINKLER HEADS TO SATISFY BUILDING, MECHANICAL, FIRE CODES, AND ANY OTHER APPLICABLE CODE($). REFER TO LIGHTING 4 HVAC PLANS. 3, VERIFY ALL SPEAKER LOCATIONS E QUANTITIES WJ TENANT. CO- ORDINATE W/ LIGHTING, HVAC, AND EXIT SIGN LOCATIONS. 4. VERIFY ALL SECURITY CAMERA LOCATIONS d LOW VOLTAGE EQUIPMENT W/ TENANT. REFER TO M-F DRAWINGS FOR CEILING FINISHES, PAINT FINISHES, ETC. 5. THE TENANT SPACE IS EQUIPPED WITH FIRE SPRINKLERS. VERIFY IN FIELD ALL EXISTING LOCATIONS, AND RELOCATE / ADD ADD- ITIONAL HEADS AS NEEDED TO COMPLY WITH ALL APPLICABLE STATE AND NATIONAL CODES (DESIGN BUILD) 6. ALL CEILINGS ABOVE FOOD PREPARATION AREAS AND BACK - OF -HOUSE AREAS SHALL BE 2'x4' WHITE VINYL FACED LAY -IN TILES. MFR.: AR STONG OR APPROVED. COMPLY WITH ALL LOCAL HEATH DEPT. REQUIREMENTS. LEGEND NOTES: INSTALL NEW CEILING d GRID m FORMER HOOD LOCATION, MFRJ STYLE/COLOR TO MATCH EXISTING GRID AND TILES NEW 2'x4' TROFFER FIXTURE TO MATCH EXISTING EXISTING 2'x4' TROFFER FIXTURE TO REMAIN U.ON. EXISTING SUSPENDED CEILING GRID 4 TILE TO REMAIN U.ON. - CLEAN GRID AND TILES TO LIKE NEW CONDITION AS NEEDED. LANDLORD NOTES: A 1. CUT SHEETS OF ALL LIGHTING FIXTURES IN FRONT OF HOUSE MUST BE SUBMITTED TO LANDLORD FOR APPROVAL. 2. IF USED ANY PEOPLE COUNTER SYSTEMS MUST BE CONCEALED FROM VIEW AT STOREFRONT. 3. ALL EMERGENCY AND EXIT LIGHTING IN FRONT OF HOUSE MUST BE EDGE LIT AND HAVE RECESSED BASE - NO SURFACE MOUNTED. 4. ALL SPRINKLER HEADS IN SALES AREA MUST BE RECESSED AND THE COVERS PAINTED TO MATCH THE SURROUNDING AREA. IN OPEN CEILINGS, SPRINKLER HEADS TO BE RAISED ENOUGH THAT THE HEADS ARE ABOVE THE GLAZING LINE AND IN LINE WITH THE LIGHTING. 5. NO FREESTANDING CAMERAS WILL BE ALLOWED IN THE SALES AREA - MUST BE RECESSED INTO WALL, ETC. 6. VERIFY LANDLORD APPROVED METHODS FOR ATTACHING TO BUILDING STRUCTURE WHEN HANGINGISUPPORTING HVAC EQUIPMENT, DUCTWORK, PIPING, WATER HEATERS, TRANSFORMERS, FIXTURES, CONDUIT, ETC. WITH LANDLORD AND TENANTS ARCHITECT. ATTACHING TO UPPER LEVEL FLOOR SLAB OR ROOF DECK IS NOT ALLOWED. CONDUIT HANGERS, CLAMPS, LIGHT FIXTURE SUPPORTS, ETC. SHALL BE FASTENED TO BAR JOISTS OR BEAMS. REVIEWED FOR CODE COMPLIANCE APPROVED APR 22 2019 City of Tukwila BUILDING DIVISION nEC -IVED CITY i;F i'i1KWIL APR 17 2019 PERMIT CENTE SPACE Z to, designs, arrangements, and data indicated on these documents are the property of G. A. Miller Architecture and were created, evolved, and I for use on, and In connection with the specified project. None of such Ideas, designs, arrangements, or data shall be used by, or disclosed to Firm, or corporation for any purpose whatsoever without permission of G. A. Miller Architecture. j81A JA o 00 VA ��.�'JI AI f�5, P rIJAi� J J J J J J J J J J J J J 141 DEL PRADO LAKE OSWEGO, OREGON 97036 503.636.7979 603.636.9898 - FAX g lenagami I lerorchitecture.com CONSULTANTS MATHEWS CONSULTING eENERAL CONTRACTOR. EM PRECISION PUYALLUP, WASHINGTON 1714,REGISTERED (ARC7 L€N A. MILLER STATE OF WA31iiNGTON. TRAPPER'S SUSHI T.I. SOUTHCENTER MALL TUKWILA, WASHINGTON J J J J J J J J J J J J J OWNER - TRAPPER'S SUSHI CO. (/r r SUSHI Co I I-ii-19 LL. COMMENTS - ADDEN. " 1 I2-14-15 L.L. REVIEW MARKI DATE I DESCRIPTION JOB NO.: 1807-13 FILE: 1807-13 A2-2 BY: PLAN CHECK NO. PERMIT NO. DATE: DECEMBER 14, 2018 C copyrlght 2018 GA MILLER ARCHITECTURE SHEET TITLE REFLECTED CEIL'G. PLAN A Z. SHEET OF File: 16VI-13 A22 Reflected Ceiling Plan.dwg Date/Time: January ID, 2019 5:213 PM Scale: 1.46 Xrefs: any person, File: 1801-13 A23 Door Schedule - Light Fixture Sched.dwg Date/Time: January 14, 20M 11:38 AM Scale: 1=46 Xrefs: 'ED GLASS 'E) DOORS STYLES °CS. 'HRESHOLD SET IC BED - ADA ANT. MFR PEMKO 'ROVED ISTING CONC. SLAB REMAIN 1rEXTIRIOP. DOOR 61" A2.3 3"=F-O" XREF(S):--- DOOR FRAME NO. SIZE MATERIAL TYPE MAT. RATING HDWR. DETAIL REMARKS 103 V-O' x l'-O' x 1 3/4' EXIST'G. FLUSH EXIST'G. EXIST'G. 105 V-O' x 8'-O' (VERIFY) GLASS B - I/A23 NOTE 4 I06 V-O' x 1'-0' x 1 3/4' EXIST'G. FLUSH EXIST'G. EXIST'G. NOTE "3 lob (E) PR. V-O' x V-O' GLASS A - EXIST'G. NOTES 1 4 3 114 3'-0' x 1'-0' x 1 3/4' EXIST'G. FLUSH EXiST'G. EXIST'G. 115 3'-0' x l'-O' x 1 3/4' EXIST'G. FLUSH EXIST'G. EXIST'G. 116 3'-0' x l'-O' x 1 3/4' EXIST'G. C EXIST'G. EXIST'G, DOORFRAME SCHEDULE NOTES: 1. DOOR TO HAVE A SIGN THAT READS 'DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED'. 2. NOT USED 3. EXISTING HARDWARE TO REMAIN, VERIFY WITH OWNER ANY ADDITIONAL HARDWARE OR LOCKSETS/KEYS ARE REQUIRED OR IF NEW HARDWARE ARE REQ'D. 4. MATCH EXISTING DOORS STYLE, RAILS, HEIGHT, CLOSER, HARDWARE, FINISH. TEMP. GLASS. A GLASS (EXISTING ENTRY) 0 /ALUE \ EXISTING HIM. DOOR WITH PANIC 'Jb0 DEVICE 4 CLOSER (TO REMAIN) c LIGHTING FIXTURE (LUMINAIRE) SCHEDULE TYPE STYLE MFR. / CATALOG NO. NO. LAMPS / TYPE WATTS VOLTS MOUNTING NOTES A EMERGENCY/EXT LITHONIA ELM-6 LED 4.3 LED 4.3 120/277 WALL OR SUSPENDED EMERGENCY / EXIT COMBO. BLACK FINISH SUSPEND CEIL'G. MTD. UNITS FROM STRUC. B EXIT LITHONIA LQHM LED B R HO RO 4.3 LED 4.3 120/277 SURFACE EXIT SIGN C 18" LED HIGH BAY MAX LITE LIGHTING T.B.D. 27 LED 27 100-277 HANGING RING MT. STUSSER ELECTRIC, ALEX - 206-623-1501 D 2'x4' TROFFER MATCH EXISTING (3) 32 W 96 120/277 RECESSED ACRYLIC LENS E FLUSH MT. CEILING LAVARDIN 1-LIGHT SEE NOTE # 4 BELOW LED - 3000K COMPATABLE 13 120 SEMI -FLUSH MT. P CUSTOM PENDANT LED - 3000K 18 120 SURFACE AQUA INSULATOR SHADE R 6" RECESSED CAN HALO PD6V120 HOUSING 16 LED - 3000K 18 120 RECESSED MINKA LAVERY GT100-F-6" EFFETRA GLASS TRIM LUMINAIRE SCHEDULE NOTES: 1. VERIFY ALL MANUFACTURERS, STYLES, COLORS, SPECS, EFC. WITH OL MER 2. VERIFY ALL SWITCH LOCATIONS WITH OWNER 3. VERIFY ANY AND ALL NIGHT LIGHT LOCATIONS WITH OWNER 4. www.wagfair =mbrowse-by-brand/pdp/lavardln-I-light=outdoor-semi-flush-mount-lrfy63O4htmViid=LED-3000K REVIEWED FOR CODE COMPLIANCE APPROVED APR 22 2019 City of Tukwila BUILDING DIVISION "A5 M1%.W1 PERIMIT CENTER All concepts, designs, arrangements, and data Indicated on these documents are the property of G. A. Miller Architecture and were created, evolved, and developed for use on, and In connection with the specified project. None of such ideas, designs, arrangements, or data shall be used by, or disclosed to any person, firm, or corporation For any purpose whatsoever without permission of G. A. Miller Architecture. sr, M JA �A ��011 o o EM Aj1 ,H1 f,5 r rU,F.4Ei J J J J J J J J J J J J J 141 DEL PRADO LAKE OSWEGO, OREGON 97035 503.636.7979 503.636.9898 - FAX glenogami I lerarchitecture.com CONSULTANTS MATHEWS CONSULTING Ge&'RAL CONTRACTOR• EM PRECISION PUYALLUP, WASHINGTON €7Ta REGISTERED ARCI#iT T CLENA ILLER STATE OF 1NASNINGT©S TRAPPER'S SUSHI T.I. SOUTHCENTER MALL TUKWILA, WASHINGTON J J J J J J J J J J J J J OWNER' TRAPPER'S SUSHI CO. P op oe kill Ir SUSHI C2 1 I 1-II-19 ADDEN. " 1 12-14-IS L.L. REVIEW MARKI DATE I DESCRIPTION JOB NO.: 1807-13 FILE: 1807-13 A2.3 BY: PLAN CHECK NO. PERMIT NO. DATE: DECEMBER 14, 2018 (c) caivurlaht 2015 GA MILLER ARCHITECTURE SHEET TITLE DOOR SCHEDULE LIGHT FIXTURE SCHEDULE A Z. SHEET OF COOLER INTERIOR BAR / DINING 5/8' PLYWOOD FACTORY APPLIED TO COOLER ? INSTALL 5/B' GYP. BD. TO PLYWOOD, t— SEE MF DUXES. FOR FINISH, TYP. FACTORT APPLIED PLYWOOD COOLER WALL 5/5' GYP. BD. - SEE MF DWGS. FOR FINISHES NEW STUD WALL - SEE FLR. PLAN E-- SEE A3 1 FOR ATTACHMENT TO -- STRICTURE ABOVE 3 5/8' MTL. STUDS ® IS I O.C. TO STRUCTURE W/ 5/6, GYP. BD. PUBLIC SIDE COOLER BOX FACTORY APPLIED 5/8' PLYW'D. 5/6' GYP. BD. - SEE MF DW35. FOR FINISHES A VERIFY LANDLORD APPROVED METHODS FOR ATTACHING TO BUILDING STRUCTURE WHEN HANGING/SUPPORTING HVAC EQUIPMENT, DUCTWORK, PIPING, WATER HEATERS, TRANSFORMERS, FIXTURES, CONDUIT, ETC. WITH LANDLORD AND TENANTS ARCHITECT. ATTACHING TO UPPER LEVEL FLOOR SLAB OR ROOF DECK IS NOT ALLOWED. CONDUIT HANGERS, CLAMPS, LIGHT FIXTURE SUPPORTS, ETC. SHALL BE FASTENED TO BAR JOISTS OR BEAMS. X 48 1220 05 . TO r Z ' c Z 48 >48 48 1220 'n 1220 1220 Nato c the be < 25" (635 mm); R A.11 h x. High Forward Reach Limit when x < 20" (Stamm) X" r 00 be 49' (1120 mm) moxlm— When x 1s 2V -2s' (510 1. s35 mm), Um r 0.11 be 44' (1120 mm) m.eh— (b) Fig. 5 Maximum Foward Reach Over An Obstruction Forward Reach ACCE551BILTY NOTE: ALL EQUIPMENT TO BE USED BY CUSTOMERS SHALL HAVE NO OPERABLE PART GREATER THAN 45 INCHES ABOVE FINISHED FLOOR. _/ N.T.5. XREF(5h-- UNI-STRUT ANCHORED TO TOP OF (E) ROOF TRUSSES / FRAMING (OR FLOOR ABOVE) a 24' O.C. - REFER TO LANDLORD PROVIDED CONST. MANUAL FOR SPECIFICATIONS 5/6, GYP. BD, ON 25 ga. STUDS ® 16, O.G. CONCEALED WIRING-- J-BOX FOR PENDANT FI: W 20 GA. MTL. STUDS 9 1W O.G. CEILING FRAMING 5/8' GYP. WALL BOARD CEILIN4 PENDANT FIXTURE - SEE RCP. a LIGHTING SCHEDULE 45� CONTINUOUS 20ga METAL TRACK ANCHORED TO (E) DECK W/ 2-08 TEK SCREWS a 24'O.C. MAX. MTL. STUD KICKERS o 24' O.G. ATTATCH TO STRUCTURE OR UNISTRUTS 4 BULKHEAD W/ (3) • 8 TEK SCREWS, TYP. 10'-2' o SUSHI BAR ti 10'-O' a LIQUOR BAR 5/8' GYP. FASCIA, I ((--SEE MF DU)GS, a LIQUOR BAR I I II I1 I1 1 f 1 1 1 I 1 I I I 1 I I I I 1 I T I (4N.T.S. ASTM A 36 1/2' THICK MIN. STL. BASE R, SEE SPECS. REFER TO DESIGN DW49. FOR PARTITION HT. STRUCTURAL GRADE 50 TYPE H 12ga STUD m 48' -O.C. MAX., SEE SPECS. INSTALL FRAMING ON EA. SIDE ANCHORS: 12'4 HILTI KWIK 5OLT-3 (3112' MIN. EMBEDMENT INTO UN - CRACKED CONCRETE SLAB) NOTE: REFER TO SPEC. SECTION 05 50 00 VERFIY WALL HEIGHT WITH DESIGN DRAWINGS A3.1 3"=1,-O" XRE:F(5): FUe= i8ID1-13 A3.1 Interior Elevations and Detailsdwg DataVTTm R: January 10, 201-3 5:30 PM Scale: 1=45 Xrefs: AT�T Art HA UNI-STRUT ANCHORED TO TOP OF (E) ROOF TRUSSES / FRAMING (OR FLOOR ABOVE) a 24' O.C. - REFER TO LANDLORD PECIFICATIONS OUTSIDE FREEZER )NTNUOUS 20ga METAL TRACK CHORED TO (E) DECK W/ 2-18 TEK REWS a 24'O.C. MAX. L. STUD KICKERS o 24' O.G. 'TATCH TO STRUCTURE 2 UNISTRUTS 4 BULKHEAD (3) Y 8 TEK SCREWS, TYP. 4INT TO MATCH ADJACENT CONST- ICTION COLOR 5/8125 ga. METAL STUDS a O.C. MAX. PROVIDE X ND iNSUL. m REST- DOM WALLS (IF NEW) TI 'X-C' MX POWER -DRIVEN STENERS a 16' O.C. (4' MIN.) W/ V EMBEDMENT :R [CC -ES CRITERIA, TYP. )LD GWB 3/8'-1/2' ABOVE CONIC )NC. S.OG FREEZER INTERIOR PENETRATION FIRESTOP FOR NOM 6" MAX DIA STEEL PIPE/CONDUIT THROUGH A GYPSUM WALLBOARD ASSEMBLY 2 HOUR GYPSUM WALLBOARD ASSEMBLY.. 1/4" BEAD 3M FIREDAM 150 CAULK. 1"MINERAL WOOL PACKING. GENERAL CONTRACTOR TO FIELD VERIFY FULL HT. - 1-HR. CONSTRUC. 3/4" DEPTH 3M FIREDAM 150 CAULK. zC C MAX. DIA. 1" MAXIMUM STEEL PIPE ANNULAR SPACE., OR CONDUIT. MIN. 28 GUAGE WOOD OR STEEL STUD. STEEL SLEEVE. UL SYSTEM # 569 Issue a— Aev. cH. PENETRATION FIRESTOP do �bWdnen�b3vkilNfw®Uw and momam"deL'dm tir>�ma,de- 1 4-01-92 6' MAX. DIA. STEEL PIPE/CONDUIT THROUGH A SLEEVED GYPSUM WALLBOARD ASSEMBLY 4"reca�� or d=i@ �lr «gin t> .rmn x m FIREDAM 150 CAULK RVAaI a"I a e,eduda do®d a x ddttu2 2 HOUR RATING PAGE I Or 2 nx KA. JFNSEN '�)L7, $CHONMER / St. P a U l DWG. I.D. 9300-MPG75.01 FIREDAMNOTE: 3M CAULK COMPLIES WITH ASTM 1556T47EIE PROPOSED OCCUPANCY: 'A-2' GENERAL CONTRACTOR TO CONFIRM FULL HT,1-HR. RATED WALL, AND INSTALL AS REQ'D. IF NOT EXISTING DUPLEX RECEPTACLES, PHONE AND DATA RECEPTACLES SHALL BE MOUNTED WITH BOTTOM OF THE OUTLET a V-3' AFF. UNLESS OTHERW15E NOTED. 1/2"=F-O" LATERAL SWAY BRACING FOR CEILINGS OVER 1.000 SF. XRERW:--- WHERE OCCURS, MOUNT THERMOSTAT DIRECTLY BESIDE LIGHT SWITCH GUTC�ES �T-STAY. LOCK/LATCH SET IN - LEVERS FOR EXIT DEVICES, LATCH - SETS, AND LOCKSETS SHALL BE CENTERED AT SAME DIMENSION ABOVE THE FINISHED FLOOR U.O.N. FLOOR AND/OR ROOF STRUCTURE ABOVE ARMSTRONG BERC2 CLIP (AS ALTERNATE MEANS OF cONSTF11CTiCN F APPROVED BY BLDG. OFFICIAL) ADDITIONAL HANGERS AT ALL MAINS WITHIN 8' OF THE PERIMETER 1/2' EMT UP TO W-10' 4 3/4' EMT UP TO 1'-S' STRUT a 12'-0' O.C. EA. WAY WITH 4 WAY LATERAL BRACING FROM THE MAIN RUNNER TO THE STRUCTURE OVER BEGIN WITHIN 6'-O' OF THE PERIMETER AND 2' FROM A CROSS MEMBER SECURE ALL HANGERS TO BLDG, STRUCTURE OR A TRAPEZE FOR DUCT 6'-O' MAX AND/OR PIPE WORK GROSS MEMBERS BETWEEN MAIN RUNNERS MAIN RUNNERS AT 4'-0' O.G. SUPPORT WTH 012 WIRE AT 4'-0' O.G. OR WITH 010 WIRE AT V-O' O.G. COUNTERSLOPE HANGERS IF MORE THAN 1:6 OUT OF PLUMB NOTES: 1. ALL CONNECTION DEVICES TO BE IBC 2012 4 ASCE 1-10 A & _APPROVED_ TYP% AND HAVE 100 LB. CAPACITY COILING DETA11.6 A3.1 N.T.5. XREF(5):--- All concepts, designs, arrangements, and data indicated on these documents are the property of G. A. Miller Architecture and were created, evolved, and developed For use on, and In connection with the specified project. None of such ideas, designs, arrangements, or data shall be used 169, or disclosed to any person, firm, or corporation for any purpose whatsoever without permission of G. A. Miller Architecture. jr A A AF1 1111 1,5,C .D UFIEc�- J J J J J J J J J J J J J 141 DEL PRADO LAKE OSWEGO, OREGON 97035 503.636.7979 603.636.9898 - FAX g I ena gams I I erarch Itecture.com CONSULTANTS MATHEWS CONSULTING GIS ERAL CONTRACTOR: EM PRECISION PUYALLUP, WASHINGTON s"' REGISTERED ti pRGj�T GLEN Mii:LER Z ESTATE DF 6IA£NIMGTDN TRAPPER'S SUSHI T.I. SOUTHCENTER MALL TUKWILA, WASHINGTON J J J J J J J J J J J J J OWNER - TRAPPER'S SUSHI CO. AS N Rellmol", hop SUS1-1 C© I 1-II-le LL. COMMENTS - ADDEN. • 1 12-14-15 L.L. REVIEW MARK DATE DESCRIPTION JOB NO.: 1807-13 FILE: 1810-14 A3-1 BY: PLAN CHECK NO. PERMIT NO. DATE: DECEMBER 14, 2018 © copyright 2018 GA MILLER ARCHITECTURE SHEET TITLE INTE NS , - , CE APR 22 2019 City of Tukwila 0 RECEIV CITY OF TU SHEET OF APR 17 O W{LA 19 PERMIT CENTER Ci7i ►P I�ij[�i3:i�j►��:�ti'l: r�il»:Ir CONTRACOR TO VERIFY ALL DIMENSIONS PAINTALL GRID, CEILING PAINTALL GRID, CEILING FURNITURE WALLTILE FURNITURE ALL EO.H.FLOORS WALLTILE WALLTILE AND TABLES AND TABLES POLISHED CONCRETE BY OTHERS BY OTHERS 1 A TRAPPER'5 SUSHI CO. - 50UTHCENTER INTERIOR ELEVATION - DINING / BRAND WALL- WEST SCALE: 1 /4" = V-O" CONTRACOR TO VERIFY ALL DIMENSIONS WALLTILE 1D TRAPPER'S 5U5H1 CO. - SOUTHCENTER INTERIOR ELEVATION - WAIT STATION / RESTROOMS - WEST SCALE: 1 /4" = 1'-0" .1 B Restaurant Design Branded Architecture 4 SI DEC CC COON CONTRACOR TO VERIFY ALL DIMENSIONS PAINT ALL GRID, CEILING UPPER WALL SECTION PI IX6 TRANSITION \ STRIP. PAINT P-2 \ P-1 22.5' 9 o i P-2 P-3 4 -1 RITE 1 BWAY G-1 FILE 4 )RATIVE AS5 WT4 FILE SS-3 RIAN b L `T 2 c, 'ERTOP H.q +.—. �q FL-1 ALL EO.H.FLOORS P-LAM BAR FRONT 1 FURNITURE S.S. F0 DT RAIL POLISHED CONCRETE WITH S.S. TOE KICK G AND TABLES TYP TYP BY OTHERS TRAPPER'S SUSHI CO. - SOUTHCENTER INTERIOR ELEVATION - SUSHI KITCHEN - EAST SCALE:1/4" =1'-0" BSR BRAND ENVIRONMENT 167 HAIDA PL, LA CONNER, WA 98257 206-856-7730 Ken Barnes: Ken@BSRBranding.com © 2018 BSR Brand+Environment GLEN A. MILLER, RA CSI NCARB GA MILLER ARCHITECTURE PC LAKE OSWEGO, OREGON Ph: 503.636.7979 PAINTALL GRID, CEILING PAINTALL GRID, CEILING BY OTHERS v CORIAN BY OTHERS V TYP COUNTERTOP �•° TRAPPER'S 5U5H1 CO. - SOUTHCENTER TRAPPER'S 5U5H1 CO. - SOUTHCENTER INTERIOR ELEVATION - WAIT STATION / DINING - NORTH INTERIOR ELEVATION - SUSHI BAR AND KITCHEN - NORTH SCALE: 1 /4" = V-O" SCALE: 1 /4" = 1'-0" FL WALLTILE FURNITURE 1F ANDTABLES BY OTHERS TRAPPER'S SUSHI CO. 50UTHCENTER INTERIOR ELEVATION - PRIVATE DINING- NORTH SCALE: 1 /4" = 1'-0" CONTRACOR TO VERIFY ALL DIMENSIONS ALL EO.H.FLOORS FURNITURE POLISHED CONCRETE 1 G ANDTABLES BYOTHERS TRAPPER'5 SUSHI CO. 50UTHCENTER INTERIOR ELEVATION - PRIVATE DINING - EAST SCALE: 1 /4" = 1'-0" TRAPPERS SUSHI COMPANY / TRAPPER O'KEEFE 718 GRIFFIN AVENUE #940, ENUMCLAW WA 98022 PROJECT LOCATION: SOUTHCENTER, 468 Southcenter Mall, Tukwila, WA 98188 JOB NO. TSCO-100118-FW REVISION NO. 6 BY: KB PLAN CHECK: KB / RH DATE: 01/14/19 FURNITURE WALLTILE 1FI AND TABLES Il BY OTHERS TRAPPER'S 5U5H1 CO. SOUTHCE R INTERIORELE AT6RVI`5M G SOUTH SCALE:114, = PWE COMPLIANCE APPROVED REC:IVED APR 22 2019 CITY OF :f'6KWILA APR 17 2019 City of Tukwila BUILDING DIVISION PERMIT CENTER SHEET TITLE: DRAWING NO. -- INTERIOR ELEVATIONS MATERIALS AND FINISHES SHEET -!-OF 3 CONTRACOR TO VERIFY ALL DIMENSIONS CONTRACOR TO VERIFY ALL DIMENSIONS PAINTALL GRID, CEILING PAINTALL GRID, CEILING PAINTALL GRID, CEILING - DECORATIVE 2 0" p_3 I L 1 P-2 P-5 �«- z'6' P-5 F-P-3-1 _------------- 2-85 y, t-T DECORATIVE P-2 P-5 __ _____ ________________ Ili fn GLASS GLASS TILE TILE WF-0 H.R. STEEL - 3'_3° C' 21'6 - BARTOWER 49° 73' Q'o;• " S TEMPERED VyT4 - WT-4 .4 _ .4 G N: i 4V 18.5 GLASS SHELVES --� SS-3 - CORION FABRICATED DESKTOP-i'THICKc"'n B MG INE -0 7T; VyT_g o s-z - VJi3 L-1 INT OR C o AOUAGLASS,s Hm wauTlLEsry 4S.B. TOEI(ICK INSTALL OVERTILEFACE— FL-1 L-1 FL-1 SS-0 S NOTE: ALLFINISHES TYPICAL WALLTILE S.S.BACKBAR ALL FO.H,FLOORS CORIAN WALLTILE CORIAN P-LAM BAR FRONT ALLF.O.H.FLOORS S.S. FOOT RAIL FURNITURE WALLTILE FURNITURE S.S. BACK BAR ALL P.O.H.FLOORS 42' 18° 42° 72° CABINETS POLISHED CONCRETE COUNTERTOP COUNTERTOP WITH S.S. TOE KICK POLISHED CONCRETE TYP AND TABLES AND TABLES CABINETS POLISHED CONCRETE 11 TYP 1J BY OTHERS BYOTFERS 1K 1M 1N 11V1 TRAPPER'5 5U5HI CO. - 5OUTHCENTER INTERIOR ELEVATION - BAR - SOUTH FACING SCALE: 1/4"= 1'-0" CONTRACOR TO VERIFY ALL DIMENSIONS BOOTH SEATING BY JH CARR P x I'HOT ROLLED STEEL U CHANEL FRAME WITH WELDED CORNERS SS WIRE MESH. INSTALL WITH HDWR FROM MANUFACTURER CORION FABRICATED CAP 1.5' THICK- RABBETTO FIT TOP OF PONY WALL CERAMIC TILE -INSTALL ON ALL INNER AND OUTER FACES 42" PONY WALL CONSTRUCTION TOP VIEW BOOTH AND TABLE 2' PONY WALL SIDE VIEW 0 Ve 6' BOOTH IS GENERALLY 72' LONG TRAPPER'S 5U51-11 CO. - 5OUTHCENTER CONSTRUCTION 42" PONY WALL - BOOTH - TYP SCALE: 3/8" = 1'-0" TRAPPER'S 5U5HI CO. - 5OUTHCENTER INTERIOR ELEVATION - BAR - EAST FACING SCALE: 114" = 1'-0" 2 ' 61 BOOTH WIDTH VARIES END OF SEAT SHOULD BE SET BACK z' FROM PONY WALL END CONTRACOR TO VERIFY ALL DIMEN51ON5 55" PONY WALL CONSTRUCTION TOP VIEW T :OL TABLE 2° SIDE VIEW LENGTH VARIES III F-6' 6° BANQUETTE SEATING BY JH CARR BACK I FACE VIEW 1' x 1° HOT ROLLED STEEL U CHANEL WIDTH VARIES FRAME WITH WELDED CORNERS H-1 SS WIRE MESH. INSTALLWITH HOWR FROM MANUFACTURER CORION FABRICATED CAP 1.5° THICK -RABBET TO FIT T 3 TOP OF PONY WALL G-`� CERAMIC TILE - INSTALL •, ON ALL INNER AND OUTER FACES ' NOTE: TYPICALLY BANQUETTE WALL HAS NO END CAP TRAPPER'S 5U5HI CO. — 5OUTHCENTER CONSTRUCTION 55" PONY WALL - BANQUETTE - TYP SCALE: 3/8" = 1'-0" TRAPPER'5 SUSHI CO. — 5OUTHCENTER INTERIOR ELEVATION - BAR- NORTH FACING SCALE: 114" = 1'-0" PAINTALL GRID, CEILING UPPER WALL SECTION Pi 1X6TRANSITION STRIP. PAINT P-2 \ TRAPPER'5 5U5HI CO. — 5OUTHCENTER CONSTRUCTION H05TESS COUNTERS - TYP SCALE: 3/8" = 1'-0" CONTRACOR TO VERIFY ALL PIMEN51ONS P•1 I Fp__1 v 4 P-2 P- EXISTING SOFFIT P-5 SOFFIT CONSTRUCTION TO MATCH EXITING P-5 P-3 U P-3 U ~ I LASSAND M T DOOR TO MA EXISTING S, z - � WINDOWFINISL SNOCHANGES EN N 6 ORS AGES WINDOWFINISH SNOCHANGES 1 FL � FL 1 WALLITILE ALL RO.H.FLOORS FURNITURE POLISHED CONCRETE 1L AND TABLES BY OTHERS TRAPPER'S 5USH1 CO. - 50UTHCENTER INTERIOR STOREFRONT ELEVATION - BAR- SOUTH SCALE: 1 /4" = 1'-O" ALL FO.H.FLOORS FURNITURE POLISHED CONCRETE AND TABLES 1 BY OTHERS TRAPPER'S 5U51-1I CO. — 5OUTHCENTER INTERIOR STOREFRONT ELEVATION - WAIT SEATING - SOUTH SCALE: 1/4" = 1'-0" REVIEWED FOR CODE COMPLIANCE APPROVED APR 22 2019 City of Tukwila BUILDING DIVISION :'ITY OF'iaK'ti`r'ILi1 Air j' 17 • is':4 A;� PAiT C7NTER DESIGNER,~ ARCHITECT: iC►V NJER: - JOB NO. TSCO-100118-FW SHEET TITLE: DRAWING NO. -- BSR BRAND ENVIRONMENT 167 HAIDA PL, LA CONNER, WA 98257 206-856-7730 Ken Barnes:Ken@BSRBranding.com • @ GLEN A. MILLER, RA CSI NCARB GA MILLER ARCHITECTURE PC LAKE OSWEGO, OREGON Ph:503.636.7979 TRAPPERS SUSHI COMPANY / TRAPPER O'KEEFE 718 GRIFFIN AVENUE #940, ENUMCLAW WA 98022 REVISION NO. 6 INTERIOR ELEVATIONS MATERIALS AND FINISHESMF 445 ■ SHEET 2 OF 3 BY' KB PROJECT LOCATION: PLAN CHECK: KB / RH @ 2018 BSR Brand+Environment SOUTHCENTER, 468 Southcenter Mall, Tukwila, WA 98188 DATE' 01/14/19 TARANTULA HILL BREWING COMPANY - INTERIORMATERIALS AND FINISHES uy k — rn m °o y I\ i € o w — T i 2' S" '� t i'-6" /�7 n rn —0 ; , �a. sk w a ^ O Lf .� _ �. � 'H-1 7:1 6--- 7 mC — - - - — — JS -- I II ' 9 0' `--- —TIE \ "" 1 E _ \ ' i' r v --, Q -- � Q r _ 1 - �_.r \ _L —� — _ — rr 1 G L -- -_ J-Q1 I I II I " 777777771 I n ( 1 H LJ Li 1 C 1A 1 B m� Er I �s -' COLUMNS IE 1J / _ 1A 1 L - 1 N E 1 K 1 REVIEWED FOR nECEIVED CODE COMPLIANCE CITY OF i UKWILA APPROVED APR 17 2019 APR 22 2019 PERMIT CENTER City of Tukwila BUILDING DIVISION ITEM MFG MOD / NO. COLOR / PTRN PRODUCT WEB LINK / INSTRUCTIONS / INFO FLOOR FINISH AND BASE FLA Polished Concrete Floor GC Finish Existing - Repair as req Gloss Dining room, restrooms, server island and other public areas NOTE: GC match all floor in Poke space with floor finish in Blue C space. FL-2 Quarry Tile Daltile OQ46 - 6"x6" Arid Flash Use for sushi and liquor bar, kitchen, foodservice, BOH areas. Install w/ min. 3/8" grout line. FB-2 Quarry Tile Base Daltile QCRL-1655! Q1655 - 6"x6" Arid Flash Use for all sushi and liquor bar, kitchen, foodservice, BOH areas. Install w/ min. 3/8" grout line. WALL TILE WT-1 Wall Tile -Kitchen MSI 4x12 Glazed Ceramic Gloss Beveled White https://www.homedepot.com/p/MSI-White-Bevelled-4-in-x-12-in-Glazed-Ceramic-Wall-Tile-13-33-sq-ft-case-NHDWH14X12BEV/206786958 WG.1 Wall Tile Grout Laticrete Tile Grout #24 Raven Sanded Seal after install WT-3 Wall Tile FOH GC Spec 6x24 - Charcoal! Black EVEN STACKED LAYOUT- Wainscot and partition walls WG-3 Wall Tile Grout FOH Laticrete Tile Grout #24 Raven Sanded Seal after install WT-4 Wall Tile FOH Mineral Tiles Aqua Pool Glass 112SI923 hit s:/Avww.mineralilles.comriddescent• ool lass-file-tur uoise-lx2! WG-4 Reflective Wall Tile Grout Bostik Dimension Urethane Grout StarQuartz, StarGlass Diamond 600 https:/A&ww.greenbuildingsu 1 .com/All-Products/Paints-Coafings•Grouts-Grout-Sealers/Dimension-Urethane-Grout PLASTIC LAMINATE FLA Formica GC LT 3156 Grey Slate MT SOLID SURFACES SS-1 Faux Glass Panels GC .5" Acrylic 3030 acrylic Polished Edge SS-2 Stainless Steel GC NSF 16 Gauge 30418-8 SS sushi cases, shelves, backsplash, kitchen surfaces. Custom fabricated by owners existing supplier. Countertops as indicated SS-3 Solid Surface Countertop GC Corm Everest hi polished surf. Sushi bar and liquor bar counter tops. 1.5" with .25" bullnose. SS-4 HR Steel Panel GC .075" (14GA) Hot Rolled Plate ASTM A36 Use for column wrap, wall panels, toe kick and base, FOH solid door kick plates SS-5 Glass Bar Shelvesl GC .5" Tempered Glass Polished Edge HARDWARE Wire Grille in HR Steel Frame GC / Boegger SS Mesh in Frame Size Varies Mount atop banquette / partition walls -- https:lAwrw.cable-mesh.com/eablemesh/ferrule-type-cable-mesh.html H-2 Back Bar Bottle Tower GC Hot rolled steel / welded const. 24" deep / size varies Bolt to back bar top and ceiling H•3 Door Hardware GC Brushed Stainless H-4 Kegworks gunmetal foot rail Floor Mount Use matching rail, comers, hdwr Install bracket 6" from barend. Space rail brackets every 48". DOORS D-1 Spec by Architect Door finishes to match wood / stain on chairs -All doors framed satin Aack (color to match 6x24 vv all tiles PAINTED SURFACES P-1 Interior Paint- Walls, Ceiling Benjamin Moore eggshell 1462 Gray Mountain Paint walls above transition strip and ceiling - customer to approve all colors prior to painting P-2 Interior Paint -Trim Benjamin Moore eggshell 210740 Driftwood Paint transition strip- customer to approve all colors prior to painting P-3 Interior Paint- Walls, Soffit Benjamin Moore eggshell 981 Winds Breath Paint walls and soffits as indicated - customer to approve all colors prior to painting P4 Interior Paint- Walls Benjamin Moore eggshell 802 San Francisco Bay Paint walls - customer to approve all colors prior to painfingl P-5 I Interior Paint- Walls, Soffit Benjamin Moore eggshell 1472 Silver Chain FURNISHINGS INTERIOR F-1 Dining Side Chair Industry West Nat Metal / Brown Stride Side Chair https:/hvwiw.industrywest.com/stride-side-chair.html F-2 Bar Stool Industry West Nat Metal! Brown Stride Bar Stool https:/Iwww.industrywest.com/stride-barstool.html F-3 Dining Tables - Steel By Owner AS Finish (no grinder) Sizes Vary F4A Table Base Foldcraf 1825-30-3-150-BL Black Table base for 30"" x 54W' table top. Two required per table top." F4B Table Base Foldcraf 1823-30-3-15Q-BL Black Table base for 30"" x 42"" tabletop. Two required per tabletop." F4C Table Base Foldcraf 1823-30.3-150-SL Black Stand up height table base for 30"" x 42- table top. Two required per table top." F4D Table Base Foldcraf 1822.42-3-15Q-BL Black Table base for 21"" x 30"" table top. " FOIE Table Base Foldcraf 1822.42-3-15Q-BL Black Stand up height table base for 21"" x 30"" table top. " F-5 Seat Fabric Maharam Pattern: Lariat Color:440401-006 Black https://www.maharam.comtproductsAa6aUcolors/006-black p-g Backrest Fabric Knoll Textiles Pattern: Diva Color: K205112 Coal https:/hrnvw.knoll.com/knolitextileproductdetail/Diva F-7 Booth Seating w/Accent Light JH Carr See JH Carr spec drawings F-8 Banquette Seating w/ Accent Light JH Carr See JH Carr spec drawings LIGHTING L-1 Pendant Lighting - Dining Landbrid e Lighting Glass Insulator Pendant- LED Blue -Green Fab with black vinyl cable L-2 Flush Mount Lighting - Ceiling Lavardin Semi Flush Ceiling Light 10h x 11"dia LED Black / Copper https:llvrww.wa aiccorrbrowse-b -brand/pdpAavardin-14! ht-outdoor-semi-flush-mount-I 384.html?piid= L-3 Recessed Lighting - Kitchen, RR Minks Lavrey Std Red Can / Glass Trim GT100-F 64n Effetre Use as needed as fill-in lighting under soffits for bar/ kitchten -- hftp:/Aww.lighgngzilia.com/min-gtl 00-f.htmi L-4 Ceiling Lighting Hi Bay Lighting Stusser Electric Black/ ribbed glass shade Mount all 12'0" aff unless otherwise indicated SIGNAGE 1 GRAPHICS SI-1 Custom Wall Mural -1 BLUE SC - Ultra Flex FS Rated Di ital Wallpaper Suede Txt. Mount interior wall - Matte fin Surface laminated - http:/Avww.ultraflexx.com/productlwallsrapes-wallcovedng/ - NOTE: Vinyl wall covering is 100 % foodservice rated i approved SI.2 Custom Wall Mural - 2 AQUA SC - Ultra Flex FS Rated Digital Wallpaper Suede Txt. Mount interior wall - Matte fin Surface laminated - http://www.ultraflexx.Gom/producttwaliscapes-wallcovednq/ - NOTE: Vinyl wall covering is 100 % foodservice rated / approved SI-3 Dimensional Restroom Lettering SC Cut out .25" metal Brushed Aluminum Mount to wall above restroom vestibule S14 ADA Restroom Sign M-W OSC Curved / Tactile Braille Brushed Alum / Elk Mount 6" from strike side doorframe @ 6 4" to center -- htts:i/www.officesi ncom an .com/curved-restroom-si n-ada-braille.as x R.R. PARTITIONS / DOORS FLA Finish all PL-1 FLOOR FINISH AND BASE FL-1 Polished Concrete Floor GC Finish Existing - Repair as req Gloss Dining room, restrooms, server island and other public areas WT-3 Wall Tile FOH GC Spec 6x24 Charcoal I Black EVEN STACKED LAYOUT - Wainscot and partition walls WG-3 Wall Tile Grout FOH Laticrete Tile Grout #24 Raven Sanded Seal after grout install P-3 Ceiling Paint Benjamin Moore eggshell 981 Winds Breath Paint ceiling on all restrooms- customer to approve all colors prior to painting OUTDOOR FURNITURE FE-2 outdoor Side Chairs BFM Largo Teak/Blk https:/twww.webstaurantstore.comfbfm-seating-phl01ctkbl-largo-outdoor-indoor-stackable-synthetic-teak-black-arm-chair/i63PHIOICTBL.htmi FE-3 Outdoor Bar Stools BFM Largo Teak! Blk https://www.webstaurantstore.comfbfm•seafing•phl02btkbi-largo-outdoor-indoor-synthetic-teak-black-bar-height-side-chair/163PH102BTBL.html FE4 Outdoor Tables BFM Longport Teak IBik https:/Iwww.webstaurantstore.com/bfm-seating-ph2424tkblu-iongport-24-square-outdoor-indoor-tabletop•, ith-black-frame-synthetic-teak/1632424TKBLU.htmi FE-1 Outdoor Table Base BFM Bali Bik Bid. Ht. https:/Mnvw.webstaurantstore.com/bfm-seatng-phtb2626bi-ball-outdoor-indoor-black-standard-height-4-leg-table-base/l63PH2626BL.html ,�, BRAN Restaurant Design & Branded Architecture DESIGNER: ARCHITECT: OWPlER. JOB NO. TSCO-100118-FW SHEET TITLE: -- DRAWING NO.BSR BSR BRAND ENVIRONMENT 167 HAIDA PL, LA CONNER, WA 98257 206-856-7730 Ken Barnes: Ken@BSRBranding.com GLEN A. MILLER, RA CSI NCARB GA MILLER ARCHITECTURE PC LAKE OSWEGO, OREGON Ph: 503.636.7979 TRAPPERS SUSHI COMPANY / TRAPPER O'KEEFE 718 GRIFFIN AVENUE #940, ENUMCLAW WA 98022 REVISION NO. 6 INTERIOR ELEVATIONS T IALS AN FINISHESMF ° SHEET 3 OF 3 BY' KB PROJECT LOCATION: SOUTHCENTER, 468 Southcenter Mall, Tukwila, WA 98188 PLAN CHECK: DATE: KB / RH 01/14/19 @ 2018 BSR Brand+Environment 2 (ETR) EXISTING 3 TON SPLIT SYSTEM HEAT PUMP x' SERVING KITCHEN WORK ROOM, OFFICEA O AND RESTROOMS TO REMAIN (E) (ETR) - - --- - X' O (ETR) O O (ETR) DINING 104 G t)- tfl I i GRIDDLE HOOD, FIRE CONTROL SYSTEM U(ETR)�� AND MAKE-UP AIR PANEL PROVIDED BY CAPTIVEAIRE AND INSTALLED BYCONTRACTOR.SEE CAPTIVEAIRE SHOP DRAWINGS I) FOR EQUIPMENT DETAILS. -1 I O 10"2 CD ' O 10"0 CD 335 CFM 335 CFM I 10"o REMOVE EXISTING i i I KITCHEN TYPE I HOOD OI O I HOOD MAKEUP AIR `7 r 1 (ETR) I! i I I I 01 7 - - - - - - PROVIDE FIRE WRAP 12"f ON ALL NEW NEW AND P�l ALTERED GREASE EXHAUS i_J 1 10"o DUCTS 1 "q 1 r - j , , 10.0 CD I 10"0 CD CONNECT TO e� 335 CFM O N I -H CONNECT TO EXISTING DUCT �H EXISTING DUCT / f I i (2 O I 335 CFM O ' O O -� OOD PRE . I REMOVE PORTION OF EXISTING 113 I SUPPLY DUCT AND REPLACE W/ NEW SECTION. NEW EXISTING EXPOSED SUPPLY AND 1 EXPOSED DUCTWORK TO BE R5TNW DUCTS AND DISTRIBUTION _J i I SPIRAL TYPE �Y$ i�TO REMAIN EXCEPT WHERE E) BA K-OF HOUS 1 THERWISE 101 x I I 1 O I I a 10"0 CD 1 10"0 335 CFM I I I I (ETR) O I — 104 CD I CONNECT TO D 335 CFM ' 1 EXISTING DUCT •x, s O O 20"m0 (ETR) / �r - - - - - - — - - - - - - J O 1 / h - --- V - - - - --- - - ENTRY o I I a 108 HOSTESS o(_J EXISTING GREASE DUCT SLOPES O O STN. �j O (E) COMMON E IT CORRIDOR X F CO RIDOR grease exh AT 1 4" PER FOOT 10 116 EXIOSTING DISHWASHER 22"0 hood muo EXHAUST SYSTEN TO REMAIN (E) ALCOVE L- ( I--------7 GREASE DUCT TOTAL LENGTH FROM HOOD CONNECTION TO ROOF FAN (ETR) 2 (ETR) IS 98' i O ;-------, O (E) MEN L- - i - 114 EXISTING 4 TON � - - - I - - - - - � 1 HVAC UNIT TO Q IFF REMAIN. REPLACE _ ' ALL SUPPLY DUCTS WITH 7 NEW SPIRAL TYPE (ETR) 18"0 14"4 12"4 EXISTING RESTROOM EXHAUST I EXPOSED SPIRAL DUCT SYSTEM TO REMAIN WOMEN 14'x6" WSR 5 ® I _ �_ _ - - 240 CFM DINING 8"0 CD - - (ETR) (ETR) (ETR) (ErR) TYPICAL OF 6 110 ----_ 150 CFM------- HVAC FLAN O O O zRVER STN. .o 1 111 I o. EXISTNG UCT UP TO SCALE- 1/4" = -fD" EXISTING 00 1' OP ------- � E UIPMEN E rn D NEW T a THERMOSTAT N N N F I — — — — — — — — — F IAI I O O BAR O 05 10"0 CD 10"0 335 CFM COUNTER DINING n 109 O REVIEWED DE COMP APPROV O APR 22 I { Ciltjl Of TUI OBUILDING D All concepts, designs, arrangements, and data Indicated on these documents are the properiy'of G. A. Miller Architecture and were created, evolved, and developed for use on, and in connection with the specified project. None of such ideas, designs, arrangements, or data shall be used by, or disclosed to any person, firm, or corporation for any purpose whatsoever without permission of Cx. A. Miller Architecture. r q tl \ 4 , vir Uwe' A J J J J J J J J J J J J J 141 DEL PRADO LAKE OSWEGO, OREGON 97035 503.636.7979 503,636.9898 — FAX g lenagamil lerarchItecture.com CONSULTANTS MATHEWS CONSULTING GENERAL CONTRACTOR: EM PRECISION PUYALLUP, WASHINGTON srfa RE41STEREO ARCt IT I!t• Z GLEN A. II LER 8TAfiE OI 1 A NINSTGN TRAPPERS SUSHI T.I. SOUTHCENTER MALL TUKWILA, WASHINGTON J J J J J J J J J J J J J OWNER: TRAPPER'S SUSHI CO. A /� P A 7r titoo SUSHI C© 1 04/15/IQ CITY MEGH GORREGTION 01/II/19 LANDLORD/ADDENDUM#I 12/16/18 GORP/OWNER REVIEW MARK DATE DESCRIPTION JOB NO.: FILE: BY: PLAN CHECK NO. PERMIT NO. DATE: copyright 2013 CAA MiLLER ARCHITECTURE T TITLE I UK NCE D 9 Vila ISION VAC PLAN M, nECE!VED SHEET OF CiTY OF i3hLVI A APR 17 2019 PERMIT CENTER EXISTING FLOOR/CEIUNG ASSEMBLY EXTREND TO EXISTING MAKE UP AIR SUPPLY DUCT EXTREND TO EXISTING GREASE DUCT 18"0 ATTIC SPACE 16 ga o 22"0 � w PROVIDE ONE HOUR FIRE WRAP o ° ON GREASE DUCT CEILING STAINLESS STEEL WHERE ST. STL COLLAR AROUND EXPOSED CEILING PENETRATION 14 : GRIDDLE HOOD —SEE CONNECT GREASE AND MAKE—UP CAPTIVENRE DETAILS DUCTS TO HOOD INSTALL HOOD CONTROL PANEL AND PROVIDE INTERFACE CONTROL WIRING PER CAPTIVAIRE REQUIREMENTS EQwPNEM er omens SECTION AT GRIDDLE HOOD NOT TO SCAIE A LANDLORD/TENANT CONSTRUCTION NOTES CONTRACTOR SHALL VERIFY LANDLORD APPROVED METHODS FOR ATTACHING TO BUILDING STRUCTURE WHEN HANGINGISUPPORTING HVAC EQUIPMENT, DUCTWORK, PIPING, WATER HEATERS, TRANSFORMERS, FIXTURES, CONDUIT, ETC. WITH LANDLORD AND TENANT'S ARCHITECT. ATTACHING TO UPPER LEVEL FLOOR SLAB OR ROOF DECK IS NOT ALLOWED. HANGERS, CLAMPS, SUPPORTS, ETC. SHALL BE FASTENED TO BAR JOISTS OR BEAMS. ITEMS PLACED ON ROOF: 1.TENANT'S GENERAL CONTRACTOR, AT TENANT'S EXPENSE, SHALL BE REQUIRED TO FURNISH TEMPORARY WEATHERPROOFING FOR ALL ROOF PENETRATIONS, UNTIL LANDLORD'S ROOFING CONTRACTOR HAS MADE FINAL WEATHERPROOF PATCHES, AT TENANT'S EXPENSE. TENANT'S STORE SPACE NUMBER SHALL BE PERMANENTLY STENCILED ON ONE SIDE OF ANY ROOF -MOUNTED HVAC UNIT, WITH MINIMUM THREE-INCH (3") HIGH LETTERS. 2.ALL ROOF AND SLAB PENETRATIONS MADE BY TENANT'S GENERAL CONTRACTOR SHALL CONFORM TO LANDLORD'S STANDARD CRITERIA AND SHALL BE SUBJECT TO LANDLORD'S APPROVAL AS TO LOCATION AND CONSTRUCTION DETAILS. WEATHERPROOFING OF ANY ROOF PENETRATIONS REQUIRED BY TENANT SHALL BE PERFORMED BY LANDLORD'S AUTHORIZED ROOFING CONTRACTOR. TENANT'S GENERAL CONTRACTOR SHALL PAY ALL SUCH COSTS, THEREFORE, DIRECTLY TO SUCH ROOFING CONTRACTOR UPON THEIR DEMAND. ANY FAILURE TO FOLLOW THIS PROCEDURE, AND ANY DAMAGES RESULTING THEREFROM, SHALL BE AT THE TENANT'S SOLE COST AND EXPENSE. 3.INSTALL ALL DUCTWORK AS TIGHT TO STRUCTURE AS POSSIBLE. ROUTE TO AVOID LIGHT FIXTURES. MAINTAIN DUCT HEIGHTS TO ACCOMMODATE CEILING HEIGHTS. REFER TO REFLECTIVE CEILING PLAN. THE ABOVE NOTES SUPERSEDE ANY AND ALL NOTES ON PLANS IN REFERENCE TO LANDLORD'S WORK: NOT WITHSTANDING ANYTHING TO THE CONTRARY WITHIN THESE PLANS AND OTHERWISE SET FORTH IN THE EXECUTED LEASE, THE TENANT ACCEPTS THE LEASE PREMISES AND ALL HVAC, ELECTRICAL, PLUMBING AND FIRE PROTECTION SYSTEMS "AS IS" AND THERE IS NO LANDLORD WORK THE LOCATION OF ALL NEW ROOF MOUNTED EQUIPMENT SHALL BE VERIFIED WITH LANDLORD PRIOR TO PLACING ITEMS ON ROOF. Type I Hood Special Inspections Type I hoods and ducts shall be inspected by approved inspection agencies that satisfy the requirements as to qualifications and reliability. Final inspection reports from such approved agencies of the Type I hood and duct shall be accepted by the code official after the special inspections of hood and duct have been completed. (2015 IMC SECTION 107 & IMC 506.3.2.5) VENTILATION DATA AIR BALANCE AC SUPPLY AIR IWO CFM MAKE UP AIR SUPPLY— 2850 CFM TOTAL SUPPLY: 10650 CFM RETURN AIR (6011) 6000 CFM HOOD EXHAUST AIR 3200 CFM DISHWASHER EXAUST AIR— 600 CFM RESTROOM EXHAUST AIR— 300 CFM TOTAL RETURN/EXHAUST 9630 CFM NET POSITIVE PRESSURE— 550 CFM SOUND UNDED PLENUM ATTACH TO DIFFUSER NECK WITH SCREWS SQUARE TO ROUND NECK CEILING NOTE: DO NOT LOCATE VOLUME DAMPERS ABOVE GYPBOARD CEILINGS FLEX DUCT SAME SIZE AS DIFFUSER NECK CLAMP --I CEILING DIFFUSER CEILING DIFFUSER DETAIL (GEILIN6 RETURNS SIMILAR) MECHANICAL LEGEND 2�/48 /¢ FLEXIBLE DUCT CONNECTION TURNING VANE SUPPLY DUCT UP RETURN DUCT UP SUPPLY DUCT DOWN RETURN DUCT DOWN AIR VOLUME DAMPER (VD) OEQUIPMENT CALL OUT �T THERMOSTAT RETURN AIR GRILLE (RAG) DUCTWORK THRU ROOF . CEILING DIFFUSER (CD) (ETR) EXISTING TO REMAIN CONICAL SPIN —IN FITTING SUPPLY DUCT HVAC NOTES: 1. INSTALL ALL WORK IN ACCORDANCE WITH STATE AND LOCAL CODE REQUIREMENTS. 2, INSULATE ALL NEW SUPPLY AND RETURN AIR RECTANGULAR DUCTS WITH 1" DUCT LINER. CONCEALED ROUND DUCTS SHALL HAVE DUCTS SHALL HAVE 1" EXTERIOR WRAP. DO NOT INSULATE EXPOSED SPIRAL DUCT. INSULATION VALUES PER WSEC, 3. THE USE OF FLEXIBLE DUCT IS LIMITED TO THAT SHOWN, NO ELBOWS. FLEX DUCTS SHALL BE FACTORY INSULATED 4. ALL DUCTS SHALL BE SEALED WITH DUCT SEALER SIMILAR TO UNITED SHEET METAL DUCT SEALER. 5. PROVIDE TESTING AND BALANCING FOR ALL NEW AND EXISTING AIR SYSTEMS. SUBMIT REPORTS TO ARCHITECT. 6. SUBMIT SHOP DRAWINGS TO ARCHITECT FOR APPROVAL OF MAJOR MECHANICAL EQUIPMENT PRIOR TO ORDERING. 7. SEE ALL OTHER DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL WORK AND CLARIFICATIONS OR WORK TO BE PERFORMED. 8. LOCATE EXHAUST DISCHARGES A MINIMUM OF 10'-0" FROM AIR INTAKES. FIELD VERIFY LOCATIONS. 9. ALL DUCTWORK SHALL BE GALVANIZED SHEET METAL CONSTRUCTED AND INSTALLED IN ACCORDANCE WITH SMACNA LOW PRESSURE DUCT CONSTRUCTION STANDARDS. SIZES SHOWN ARE INSIDE CLEAR DIMENSIONS. MAKE ALLOWANCE FOR INTERNALLY LINED DUCTWORK. REVIEWED FO 10. RELOCATE AND RECONNECT EXISTING THERMOSTATS AND CONTROLS AS REQUIRED. CODE CO CONTROL. PROVIDE REMOTE SENSORS AND LOCKING COVERS APPROVED 11. CONNECT NEW SUPPLY AND RETURN DUCTS TO EXISTING UNIT DUCTWORK DISTRIBUTION SYSTEM. APR 22 2019 12. ALL EXPOSED DUCTWORK SHALLSPIRAL WOUND AND BE FACTORY FINISHED — BLACK COLOR. 13. REMOVE ALL EXISTING MECHANICAL NOT NOTED TO REMAIN AND/OR NOT REQUIRED BY NEW WORK. City ofTUkwila EXISTING MECHANICAL ITEMS THAT ARE TO REMAIN SHALL BE REROUTED AND RECONNECTED BUILDING DIVIS AS REQUIRED BY NEW TENANT SPACE DESIGNS. 91010 DA3 All concepts, designs, arrangements, and data indicated on these documents are the property of G. A. Miller Architecture and were created, evolved, and developed for use on, and in connection with the specified project. None of such ideas, designs, arrangements, or data shall be used by, or disclosed to any person, firm, or corporation for any purpose whatsoever without permission of G. A. Miller Architecture. F" M 'A J J J J J J J J J J J J J 141 DEL PRADO LAKE OSWEGO, OREGON 97035 503.636.7979 503.636.9898 — FAX glen®gcimll lerorchitecture.com CONSULTANTS MATHEWS CONSULTING GENERAL CONTRACTOR: EM PRECISION PUYALLUP, WASHINGTON 67 i4. REGISTERED; fYRt+�IT G, LE A. ILLER STATE OF WA"NII#GTon TRAPPER'S SUSHI T.I. SOUTHCENTER MALL TUKWILA, WASHINGTON J J J J J J J J J J J J J OWNER: TRAPPER'S SUSHI CO. Arti- kkwolw SUSHI Ga OI/II/I9 LANDLORD/ADDENDUMui 12/16/I5 GORP/OWNER REVIEW MARKI DATE I DESCRIPTION JOB NO.: FILE: BY: PLAN CHECK NO. PERMIT NO. DATE: @ copyright 2013 GA MILLER ARCHITECTURE SHEET TITLE HVAC DETAILS I E 1 I N M,Z SHEET lECE%�fcDWILA APR 17 2019 PERMIT CENTER ELECTRICAL LEGEND TWO WAY SWITCH $3 THREE WAY SWITCH $2p TWO POLE SWITCH $D SWITCH WITH DIMMER $OS SWITCH WITH OCCUPANCY SENSOR DUPLEX RECEPTACLE, +18" TO CENTER LON &U RECEPTACLE WITH USE! CHARGING PORTS, +18" TO CENTER LON FOURPLEX RECEPTACLE, +18" TO CENTER LION GFI DUPLEX RECEPTACLE, +18" TO CENTER LON ISOLATED GROUNG ORANGE DUPLEX RECEPTACLE Q JUNCTION BOX JJ DOUBLE GANG JUNCTION BOX ® SPECIAL RECEPTACLE G) DIRECT CONNECTION AFF ABOVE FINISHED FLOOR SU STUB UP (OUT OF FLOOR) CM CEILING MOUNT RECEPTACLE IG ISOLATED GROUND WP WATERPROOF GFI GROUND FAULT ® TiME CLOCK 01 TELEPHONE/DATA - 1" C. TO BKBD Q CABLE OUTLET W/RG6 SHIELDED CABLE TO BKBD 0, DISCONNECT SWITCH 0 MOTOR CONNECTION 'WtiP FLEXIBLE CONNECTION TO EQUIPMENT — — — CONDUIT RUN BELOW FLOOR OR CONCEALED IN WALL CONDUIT RUN CONCEALED IN CEILING OR IN WALL NO, OF WIRES IN CONDUIT - (2) #12 & GIRD MINIMUM i BRANCH CIRCUIT HOME RUN BRANCH PANEL130ARD ® TRANSFORMER A INDICATES LIGHT FIXTURE TYPE. PENDANT LIGHT SPOT LIGHT COMPACT FLUORESCENT TRACK LIGHT EXIT LIGHT W/ EMERGENCY BATTERY PACK /® 11�'T WALL SCONCE 24"x 48" LIGHT FIXTURE N.L. NIGHT LIGHT (ETR) EXISTING TO REMAIN LANDLORD/TENANT CONSTRUCTION NOTES IF CORING IS REQUIRED - PROVIDE CORING PLAN TO LL AND BASE BUILDING 0 STRUCTURAL ENGINEER FOR REVIEW AND APPROVAL. TENANT GC TO SCAN SLAB PRIORM TO CORING T. 9 4 (E) ELEC./STOR. (E) OFFICE 102 103 EXISTING PANELS 8 A', 'B' AND 'LP' B-15,17 B-13 L A-29 EL 3 DINING 104 A-17,19 I 01 ,46 FOOD PREP. A-6 113 I 15A - - ----- I �`I 1 I I A-8 -13: 115a18;1 '+46' 'J — - 5A A-10 8 A-22'' tl (E) BACK -OF -HOUSE 101 I A-33 11511 15A I I RELOCATE AND RECONNECT A L i �I EXISTING HOOD, EXHAUST FA AND MAKE-UP AIR CONTROLS TO NEW HOOD LOCATION AN RECONNECT 511 A 12 = -= 1 A-1 I ,o A-1 I II A-37 A-18 I o �o 57 +42° +2 " 92 (E) COMMON EXIT CORRIDOR EXIT CORRIDOR 00 16 I (E) ALCOVE II 112 (E) MEN 114 ❑3 r , POWER PI_,4N Z SCALE: 1/4" = I'-0" M N -H STORAGE 106 17 132" 16 +1 B-12, B-16 32" BEER COOLER A-35 15 -(O} B- B-20 LP VIA TIME CLOCK J ----- - SIGN j\� 116 /�6-124 BAR 105 I B-22 II I L�-------------------- II J_JI II ENTRY 108 uoe STN __- A-39 57 a --, L- 133+24" -1 i--- - - - - i I 134 s" -- i 1 +24° 129 i C-2 C 1 4 WOMEN _ '48" 130 - '- - - - - - _ I COUNTER DINING 109 � I 135 r------+ �C-4, C-8- - - - - --F3 F I 1 - - - -- 110 i -------- j ®SERVER STN. % - - =---I DINING 111 � � - - - - - - 7 REVIEWED I 1 1 DE COMPI APPROV.. APR 22 2 , 9 6 City of Tuk C-7 BUILDING DI' EXISTING PANEL 'C' All concepts, designs, arrangements, and data indicated on these documents are the property of G. A. Miller Architecture and were created, evolved, and developed for use on, and In connection with the specified project. None of such ideas, designs, arrangements, or data shall be used by, or disclosed to any person, firm, or corporation for any purpose whatsoever without permission of G. A. Miller Architecture. r2q \ A N1 L IlF1 J J J J J J J J J J J J J 141 DEL PRADO LAKE OSWEGO, OREGON 97035 503.636.7979 503.636.9898 - FAX glenogami I lerarchltecture.com CONSULTANTS MATHEWS CONSULTING GENERAL CONTRACTOR: EM PRECISION PUYALLUP, WASHINGTON 67td Riw{iISTREn GLEN A BILLER STATE OF WA lINSTON ' TRAPPER'S SUSHI T.I. SOUTHCENTER MALL TUKWILA, WASHINGTON J J J J J J J J J J J J J OWNER: TRAPPER'S SUSHI CO. �/� t/r SUSI-11 C2 01/11/111 LANDLORD/ADDENDUM#1 12/16/18 I CORP/OWNER REVIEN MARK DATE I DESCRIPTION JOB NO.: FILE: BY: PLAN CHECK NO. PERMIT NO. DATE: (c� copyright 2013 GA MILLER ARCHITECTURE SHEET TITLE POWER PLAN OR NCE 19 ila SION E— CIT 13EGEstfCD CIF , �><4ti1Lq Z HEET OF flrK 112919 PERA11T CENTER 2 M (E) ELEC. STOR. (E) OFFICE 102 Ul 03 H. LA H H DINING 04 0 .H, E .H. O •H• O I LP-1,3 F� (ETR) i�. O O O LP-5 P I I EXISTING DIMMER SWITCHES ® I RECONFIGURE AS INDICATED. f f I 1P_7 y RELABEL ALL'LEI I 0 ( ' I -144"k ® O ® i I A. P N i H - O CONNECT TO EXISTING EMERGENCY LIGHTING CIRCUIT LP-6 THROU H EXISTING DAYLI T SENSOR 1 �H F A I O r F' DOD PREP. 0 113 O BA K-OF HOUS P DINING 01 I-0 - PI Ma. 0 HH _;_ __ STING (ETR) ® f ® ® EMERGENCY LIGHTING CIRCUIT I I ® ® ® II I DA C O \ f' E LP-14,16 % — (ETR) C, (E) COMMON EXIT CORRIDOR EXII CORRIDOR H 100 (ETR) (ETR)R) 116 --- OA LP-17,19 OA © O O O O �F R) �ETR ENTRY 10, Hosmss off STN. 'D. p, (E) ALCOVE I I ------- 112 �— —J I (ETR) ED" I (ETR) (E) MEN WOMEN L= O --- -- ©E © E ©E 114 115 r -- ,---- --� O O I- -- - - - a OA — --- ---7 COUNTER DINING I iE :P1 r 109 SERVER STN. I i 111 I--- ----1 z G ---- DINING i 110 I © E REVIEWEI CODE COMF APPROi , -- -UU O APP, 22 Li City of Tu BUILDING D LIGHTING f'L,4N z SCALE: 1/4" = 1'-0" All concepts, designs, arrangements, and data indicated on these documents are the property of G. A. Miller Architecture and were created, evolved, and developed for use on, and in connection with the specified project. None of such Ideas, designs, arrangements, or data shall be used by, or disclosed to any person, firm, or corporation for any purpose whatsoever without permission of G. A. Miller Architecture. J J J J J J J J J J J J J 141 DEL PRADO LAKE OSWEGO, OREGON 97035 503.636.7979 503,636.9898 — FAX g I en(ggomi l I erarchitecture.com CONSULTANTS MATHEWS CONSULTING GENERAL CONTRACTOR: EM PRECISION PUYALLUP, WASHINGTON 11714 REGISTERE6 ARC�IT T GLE' A, ICLER STATE OF WAMMOTOR TRAPPER'S SUSHI T.I. SOUTHCENTER MALL TUKWILA, WASHINGTON J J J J J J J J J J J J J OWNER: TRAPPER'S SUSHI CO. N R!:e0lo ah SUS141 Ca OI/Ii/lq LANDLORD/ADDENDUMM 12J16/18 CORP/OWNER REVIEW MARK DATE I DESCRIPTION JOB NO.: FILE: BY: PLAN CHECK NO. PERMIT NO, DATE: copyright 2013 GA MILLER ARCHITECTURE SHEET TITLE LIGHTING PLAN 1 FOR IANCE D i ila IllsION E-/_ SHEET OF nr:_ CITY OF i U MVILA APR 17 2019 PERMT CENTER ------------ ----------------------------------- ----------- O�ppl�l COOLER FREEZER ERTITFZ TO REMAIN 1101ppp101 � • ' - • • � I������I 0111•li•p101 I������I ®IMMMIOI _ • - O • - I����••I ®IMMMlol • PR .- 4 - IJ����liiiiii■I 0IMMMI01 • - I����li•liiiil•I Il�,�pp101 .. - I� • ■■®pal •- 01►4,���loi = • ' - . Ili• „- ■�®pal 01►_'p•l01 -- •- Ili•�� •% pal I•II•��I�I I� ���I•I �I�pl•II•I I�����I•I NMI �II•I•�I�I II••I• ��1 101pp►�•l01 ••► I �©01�-P�I •- NMMM MAKE-UP AIR FAN HEATER M W�l II•I•����I �I � �I I I����I•�I 0��►a�101 • I����pl�lIIIIIIIIIIIIINRAW �I�p�l�l I��� pl•I ���pl�l I�•I•���I �I�I•�II.I I���•��I 0lpppl�l I��I•���I - I=IE)il�MMI�i PAN TOP REFRIGERATOR �I I•I• II•I I� ��p�l • �I�LI.ILI I������I �p�pl�i I����p�l • - INDIRECT WA5TE, VERIFY RECIUIREMENTS WITH OWNER �ppl�i I�•����I NEMA - DEDICATED / 15OLATED, VERIFY REQUIREMENTS OF 0"R PROIADED EQUIPMENT �I�I•LILI I��� I•�I - . - • �I��LI�I I �����I �Ip•pi� I������I • - • a ♦ • --• • • • - ELECTRICAL NOTES: 1, RECEPTACLE MOUNTING HEIGHTS NOT INDICATED ON ELECTRICAL PLAN SHALL BE AS CALLED FOR ON THE ARCHITECTURAL DRAWINGS. ALL GENERAL PURPOSE RECEPTACLES SHALL BE MOUNTED AT 16" A.F.F. 2. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL COMPLETE ALL MATERIALS, EQUIPMENT, AND LABOR AS SHOWN AND AS NECESSARY FOR COMPLETE WORKABLE SYSTEM. ALL MATERIALS AND EQUIPMENT SHALL BE NEW MATERIALS AND FREE FROM ANY DEFECTS. Qi U.L. LISTED COMPONENTS REQUIRED. COMPLY WITH ALL GOVERNING CODES AND ORDINANCES. 3. TYPICAL SWITCH HEIGHT IS +48" A.F.F (U.O.N) 4. ALL TELEPHONE/DATA CABLE IS TO BE PLENUM RATED WIRE OR NON -RATED WIRE INSTALLED IN CONDUIT ABOVE CEILING OR IN WALLS. 5. CONTRACTOR TO SURVEY FIELD CONDITIONS AND VERIFY THAT WORK IS FEASIBLE AS SHOWN. VERIFY LOCATIONS OF ALL OUTLETS IN RELATION TO STRUCTURAL AND OTHER ELEMENTS AS REQUIRED. NOTIFY ARCHITECT IN WRITING OF DISCREPANCIES. 6. INCOMING TELEPHONE/DATA UNES(4) SHALL TERMINATE IN TERMINAL BLOCKS LIGHTING FIXTURE (LUMINAIRE) SCHEDULE TYPE STYLE MFR./CATALOG NO. NO. LAMPS/TYPE WATTS VOLTS MOUNTING NOTES A EMERGENCY LITHONIA 4.3 LED 4.3 120/277 WALL OR EMERGENCY. BLACK FINISH ELM-6 LED SUSPENDED SUSPEND CEILING MTD UNITS STRUCTURE B EXIT LITHONIA 4.3 LED 4.3 120/277 SURFACE EXIT SIGN LQHM LED B R HO RO C 18" LED HIGH BAY ELT LIGHTING 27 LED 27 100-277 HANGING RING MT. STUSSER ELECTRIC, ALEX - 206-623-1501 T.B.D. D 2'x4' TROFFER MATCH EXISTING (3) 32 W 96 120/277 RECESSED ACRYLIC LENS E FLUSH MT. CEILING LAVARDIN 1-LIGHT 13 120 SEMI -FLUSH MT. SEE NOTE #4BELOW LED -3000KCOMPATABLE P CUSTOM PENDANT T.B.D. LED - 3000K 18 120 SURFACE AQUA INSULATOR SHADE R 6" RECESSED CAN HALO PD6V120 HOUSING 16 LED - 3000K 16 120 RECESSED MINKA LAVERY GT100-F 6" EFFETRA GLASS TRIM LUMINAIRE SCHEDULE NOTES: L YMIFY ALL MANFACIURERe, SMES, COLORS, OPEC$. ETC, UATH DINER 2. YERFY ALL OUITCH WrATICNS UM OUNER I VEPoFT ANY AND ALL NIGHT LIGHT LOCATIONS wTH OMM 4. anw•ayfakeomAxoae••by-brand�pe$a/lavardin•I-n�t•outdaa'-eeml•fpieh-mask-N1y6384htmlfpUd•L®-30D61c ADJACENT TO P.O.S. BACKBOARD. (EXIST (EXIST' 7. REMOVE ALL EXISTING ELECTRICAL NOT NOTED TO REMAIN AND/OR NOT REQUIRED BY NEW WORK. EXISTING ELECTRICAL ITEMS THAT ARE TO REMAIN SHALL BE REROUTED AND RECONNECTED AS REQUIRED BY NEW TENANT SPACE DESIGNS. 8. ALL SWITCHES (LIGHTS, EQUIPMENT ETC.) TO BE INSTALLED IN APPROPRIATE LOCATIONS, ACCESSIBLE TO APPROPRIATE AREA. VERIFY WITH OWNER ANY CONFLICTING SWITCH LOCATIONS. 9. RESTROOM SWITCH TO HAVE OCCUPANCY SENSORS 10. SERVICE AREA SWITCHES TO BE MOUNTED AS DETAILED 11. ALL EQUIPMENT OUTLETS AND SWITCHES TO BE LABELED WITH TYPE WRITTEN, SELF-ADHESIVE LABELS. 12. ELECTRICAL CONTRACTOR TO SUPPLY AND INSTALL POWER CORDS AS REQUIRED FOR EQUIPMENT AND MAKE FINAL CONNECTIONS. 13. ELECTRICAL CONTRACTOR TO SUPPLY AND INSTALL TIMER FOR EXTERIOR SIGNAGE. LOCATE TIMER CLOSE TO PANEL. 14. CONTRACTOR TO WRAP & TIE CORDS TO BACK OF INTERIOR SIGNAGE. 15. CONTRACTOR SHALL ANCHOR ALL CEILING MOUNTED RECEPTACLES TO BUILDING STRUCTURE 16. SOME MILLWORK MODULAR COMPONENTS MAY BE SUPPLIED WITH OUTLETS. USE OUTLETS IN THOSE COMPONENTS FIRST BEFORE ADDING NEW ONES. 17. PROVIDE P.O.S./PHONE DATA LINES. VERIFY REQUIREMENTS. RUN IN CONDUIT AND TERMINATE AT BACKBOARD INDICATED IN WORKROOM. PANEL LOCATION: 120/208 VOLT 1 3 PHASE 4 WIRE C SERVING: 225 AMP WITH MAIN CIRCUIT BREAKER CRK LOAD DESCRIPTION CODE VA CBIP PHASE CB/P I VA ICODE LOAD DESCRIPTION CRK 1 STOREFRONT SIGN A 20/1 1440 SODADISPENSER (129) 2 3 STOREFRONT LIGHTING 20/1 B 20/2 2028 K HOTWATER DISPENSER (130) 4 5 C 2028 K Il 6 7 HOUSE RECEPTACLES R 720 20/1 A 20/1 960 K FOOD WARMER (135) 8 9 B 10 11 C D VAVCONTROLS 12 13 A 14 15 B 2011 660 K FOOD WARNER (134) REFRIG (133) 16 17 C 18 19 A 20/2 1440 K ICE MACHINE (132) 20 21 B 1440 K II 22 23 C 24 25 A 26 27 B 28 29 C 30 31 A 32 33 B 34 35 C 36 37 A ELECTRICHEAT STRIP 38 39 B II 4D 41 C II 42 PHASE A=1 16425 1 PHASE B =1 689 PHASE = 18612 LOAD TYPE L R M H AC D K E W H LM TOTAL LOADS CONNECTED LOAD: 0 720 0 0 0 0 8556 0 9276 1 VA IAMIF'S DEMAND LOAD: 1 01 7201 01 01 01 01 85561 01 1 1501 9426 1 VA IANTS REMARKS: PANEL IS EXISTING -MODIFY CIRCUITING AND ADD/REMOVE BREAKERS AS REQUIRED (EXIST) (EXIST) (EXIST (EXIST (EXIST (EXIST (EXIST (EXIST (EXIST (EXIST (EXIST) (EXIST; (EXIST; (EXIST,' (EXIST; (EXIST; (EXIST, PANEL LOCATION: 120/208 VOLT 3 PHASE 4 WIRE A SERVING: 225 AtvP WITH MtAIN CIRCUIT BREAKER CRK LOAD DESCRIPTION CODE VA CB/P PHASE CB/P VA CODE LOAD DESCRIPTION CRK 1 OFFICE/ STORAGE RM RECEPTACLES R 600 20/1 A 20/1 600 K REFRIGERATION UNITS (30) (84) 2 3 CORRIDOR AREA LIGHTS L 800 20/1 B 20/1 360 K RICE WARMER (29),SUSHI CASE (92) 4 5 BIB RACK D 360 2011 C 20/1 1560 K MICROWAVE OVEN (83) 6 7 DINING AREARECEPTACLES R 540 20/1 A 20/1 600 K REFRIGERATION UNITS (30) (84) 8 9 DINING/BATH RECEPTACLES R 720 20/1 B 20/1 360 K RICER WARMERS (29) 10 11 ENTRY RECEPTACLES R 360 20/1 C 20/1 600 K REFRIGERATION UNITS (30) (84) 12 13 HEAT LAMPS (8 1) L 400 20/1 A 20/1 360 K RICE WARMER (29),SUSHI CASE (92) 14 15 PHONE RECEPTACLE D 500 20/1 B 20/1 1560 K MICROWAVE OVEN (83) 16 17 KITCHEN RECEPTACLES R 540 2011 C 2011 1560 K MICROWAVE OVEN (83) 18 19 KITCHEN RECEPTACLES R 540 20/1 A 20/1 360 D GAS WRIER HEATER 20 21 REFRIGERATION UNITS (55) (67) K 980 20/1 B 20/1 1560 K MICROWAVE OVEN (83) 22 23 C 24 25 COOLERIFREEZER DOOR HEATERS A 30/1 2880 D HAND DRYER 26 27 B 30/1 2880 D HAND DRYER 28 29 POS PRINTER (57) DEDICATED D 400 20/1 C 30P2 2850 D IHP-1 30 31 POS PRINTER (57) DEDICATED D 400 20/1 A 2850 D IHP-1 32 33 POS PRINTER (57) DEDICATED D 400 20/1 B 30/2 2200 D OHP-1 34 35 POS PRINTER (57) DEDICATED D 400 20/1 C 2200 D OHP-1 36 37 POS PRINTER (57) DEDICATED D 400 2011 A 38 39 POS PRINTER (57) DEDICATED D 400 20/1 B 40 41 C 42 ' PHASEA=) 16425 PHASEB= 17689 PHASE = 18612 LOAD TYPE L R M H AC 0 K E WH LM TOTAL LOADS CONNECTED LOAD: 1200 3300 0 0 0 11480 10100 0 34080 1 VA AMPS DEMAND LOAD: 1 15001 33001 01 01 01 194801 10100 0 310 34690 1 VA 96 AMPS REMARKS: PANEL IS EXISTING -MODIFY CIRCUITING AND ADD/REMOVE BREAKERS AS REQUIRED PANEL LOCATION: 120/208 VOLT 3 PHASE I ­L WIRE B SERVING: 225 AMP WITH MAIN CIRCUIT BREAKER CRK LOAD DESCRIPTION CODE VA CB/P PHASE I CB/P VA 1CODE LOAD DESCRIPTION CRK 1 KITCHEN HOOD D A COOLER UNIT 2 3 KITCHEN HOOD D B COOLER UNIT 4 5 KITCHEN HOOD D C FREEZER 6 7 HOOD LIGHTS L 400 20/1 A FREEZER 8 9 HOOD FIRE & CONTROL PANEL D 1200 20/1 B 10 11 C 2012 1120 K BEER COOLER COMPRESSOR 12 13 SODA DISPENSER(129) K 1440 2011 A 20/1 1120 K 14 15 HOT WATER DISPENSER (130) K 2028 20/1 B 20/1 864 K COOLER COIL, LIGHTS 16 17 II K 2028 20/1 C 20/1 864 K -15 18 19 FOOD WARNER (135) K 960 2011 A 20/1 1044 K SODA GUN (110), COOLER (115) 20 21 FOOD WARMER (134), REFRIG (133) K 660 2011 B 20/1 852 K GLASS CHILLER (118) 22 23 KITCHEN DISHWASHER C 20/2 1248 K DISHWAS5ER(112) 24 25 A 1248 K I( (I 26 27 B 28 29 ROCIFTOP GAS/ELECTRIC UNIT C 30 31 ROOFTOP GAS/ELECTRIC UNIT A ROOF GFCI 32 33 ROOFTOP GASIELECTRIC UNIT B 34 35 C 36 37 A 38 39 B 40 41 C 42 PHASE A=) 16425 1 PHASE B =1 17689 PHASE _' 18612 LOAD TYPE L R M H AC D K E W H LM TOTAL LOADS CONNECTED LOAD: 400 0 0 0 0 1200 15476 0 17076 1 VA AMPS DEMAND LOAD: 1 5001 01 01 01 01 12001 154761 01 1150 17326 1 VA I JAMPS REMARKS: PANEL IS EXISTING -MODIFY CIRCUITING AND ADD/REMOVE BREAKERS AS REQUIRED PANEL LOCATION: 120/208 VOLT I 3 PHASE 1 4 WIRE LP I SERVING: 225 AMP WITH MAIN: CIRCUIT BREAKER CRK LOAD DESCRIPTION CODE VA CB/P PHASE CB/P VA CODE LOAD DESCRIPTION CRK 1 DINING 104 LIGHTING 800 A 1200 TIME CLOCK 2 3 FOOD PREP COUNTER LIGHTING 440 B 1200 TIME CLOCK 4 5 FOOD PREP LIGHTING 600 C 700 WINDOW AREA LIGHTING 6 7 DINING 107 LIGHTING 800 A EXISTING 8 9 BAR 105 LIGHTING 660 B EXISTING 10 11 EXISTING C EXISTING 12 13 EXISTING A 340 HOSTESS AREA LIGHTING 14 15 B 600 CENTERDINING LIGHTING 16 17 JOINING 110 LIGHTING 600 C 18 19 SERVER 111 LIGHTING 240 A EXISTING 20 21 B EXISTING 22 23 EXISTING C EXISTING 24 25 A 26 27 B 28 29 C 30 31 A 32 33 B 34 35 C 36 37 A 38 39 B 40 41 42 PHASE A= ) PHASE B =1 I PHASE = LOAD TYPE L R M H AC D K E WH LM TOTAL LOADS CONNECTED LOAD: 1i oil 01 01 01 01 01 01 111 1 1 0 1 VA Jill 1 MiPS DEMAND 1 01 01 01 111 01 01 01 01 1 VA AMPS REMARKS: PANEL IS EXISTING - MODIFY CIRCUITING AND ADD/REMOVE BREAKERS AS REQUIRED (EXIST) (EXIST) (EXIST) (EXIST) (EXIST) (EXIST) (EXIST) (EXIST) (EXIST) (EXIST) (EXIST) (EXIST) REVIEkNED FOR CODE COMPLIANCE APPROVED APR 22 2019 City of Tukwila BUILDING DIVISION All concepts, designs, arrangements, and data Indicated on these documents are the property of G. A. Miller Architecture and were created, evolved, and developed for use on, and in connection with the specified project. None of such ideas, designs, arrangements, or data shall be used by, or disclosed to any person, firm, or corporation for any purpose whatsoever without permission of G. A. Miller Architecture. 914 .041ew" J J J J J J J J J J J J J 141 DEL PRADO LAKE OSWEGO, OREGON 97035 503.636.7979 503.636.9898 — FAX glen®gams I I erarchitecture.com CONSULTANTS MATHEWS CONSULTING GENERAL CONTRACTOR: EM PRECISION PUYALLUP, WASHINGTON 6714 REGISTERED ARG j1T GLEN X ILLER STATE CIE WASHINGTON TRAPPER'S SUSHI T.I. SOUTHCENTER MALL TUKWILA, WASHINGTON J J J J J J J J J J J J J OWNER: TRAPPER'S SUSHI CO. er ,, \ S Lr S M Q OVII/Iq LANDLORD/ADDENDUM#I 12/I6/18 GORE'/OWNER REVIEW MARK DATE DESCRIPTION JOB NO.: FILE: BY: PLAN CHECK NO. PERMIT NO. DATE: copyright 2013 GA MILLER ARCHITECTURE SHEET TITLE ELECTRICAL SCHEDULES E - 33 nECFIV=O CITY OF 1i}ii41iIL 5NEET OF ^ % , I zud PERMIT CENTER PLAN NOTES OCONNECT TO EXISTING GREASE WASTE LINE BELOW FLOOR OCONNECT TO EXISTING 120' HOT WATER LINE ABOVE CEILING OCONNECT TO EXISTING COLD WATER LINE ABOVE CEILING ®CONNECT TO EXISTING 3" VENT ABOVE CEILING OCONNECT TO EXISTING 2" VENT ABOVE CEILING ©CONNECT TO EXISTING 2-i/2" GAS LIN OV ILIN 07 PROVIDE AND INSTALL WATTS LF009 1/2" REDUCED PRESSURE 'PROVIDE DEVICES AT ICE MACHINE AND SODA DISPENSERS. PROVIDE AIR GAP CONNECTION AND PIPE TO FLOOR SINK. Al EXISTING WATER HEATER M I I� 10IF FEXVSTING WATER T, g SERVICE AND DINING VALVES 104 - (E) ELEC./STOR. (E) OFFICE 102 103 7 0 i X w I 129 ' +zzi' 130 I n GAS EMERGENCY AN (I 129 +22 3 I MANUAL VALVES I II EXISTING 22" _ _ I EXISTING E6EER COOLER Q4" 32 IL �1 _ FD I I 2 — — — EXISTING - } _ — — — — t� J EXISTING �J I EXISTING G 4- 4 __48 4„ EXISTING��g-- - GW GW W GW GW = _ - FO D PREP.O� MUZ 1 '�aa qg RUN WATER A D VENT I — N 1-1/2" GAS 71 I I LINES BELOW LOOR II 16 FL 117 BAR w HEADER 34 M8 I V I I I I I 17 _ FD s0 Me I 3J4" 05 ------- ;; II 2 30° 68 I I 1 j I I -FD L ------ ------ ---- I !I N E) BACK-OF-H SE i5 _ — _ 2' I I wF 101 I 105 MB 111 1z" 11 0 12 4 66 1 1089112 I 111 DINING 105 M8 I ,i'J 113 107 I - I I N W I I 3"LMMI II I I� 3 24" ( EXISTING GW �—GW I 33 2r' \ ,r; z \ rr _ ---------- -1 w (E) COMMON EXIT CORRIDOR EXIT CORRIDOR 1001 116 (E) MEN 14 0 3 I 3 i EXISTING I I 2 3/4" i � ------- a (E) ALCOVE 112 2'� ° L—_ _ ------- ® i 1 FS I — —FFL 7 129 I 129f22' i T ------- - VEE OM 115 L — r— 30 _ -------, J, I I 4] 125 2"-A Iz 24' 126 -------� 4------- PLUIEEBING PLAN (1z tQ SCALE: 1/4" - 1'-0" SERVER STN. --T2, 32 i------- � 7 FD FS 132 i CO '------- 8. T. EXISTING ii 3 LL-11 IF -3 DINING 110 Ho: 5TN -H STORAGE 106 N ENTRY 108 COUNTER DINING 09 VIEWEED F )E COMPEL APPROVEI APR 22 201 'Ity of Tukw _DING DIVI All concepts, designs, arrangements, and data indicated on these documents are the property of Cs. A. Miller Architecture and were created, evolved, and developed for use on, and in connection with the specified project. None of such ideas, designs, arrangements, or data shall be used bS, or disclosed to any person, firm, or corporation for any purpose whatsoever without permission of Cs. A. Miller Architecture. WAlid, " J J J J J J J J J J J J J 141 DEL PRADO LAKE OSWEGO, OREGON 97035 503.636.7979 503.636.9898 - FAX glen®gami I lercirchitecture.com CONSULTANTS MATHEWS CONSULTING GENERAL CONTRACTOR: EM PRECISION PUYALLUP, WASHINGTON � t REGISTERE101 ARCgI T GEE MILLER STATE OF WACHINGTON TRAPPER'S SUSHI T.I. SOUTHCENTER MALL TUKWILA, WASHINGTON J J J J J J J J J J J J J OWNER: TRAPPER'S SUSHI CO. SUSHI Co 1 04/I/Iq OITY GORREOTION5 #1 01/II/Iq LANDLORD/ADDENDUM#I 121I6/18 GORP/OWNER REVIEW MARK DATE DESCRIPTION JOB NO.: FILE: BY: PLAN CHECK NO. PERMIT NO. DATE: (c� copyright 2013 GA MILLER ARCHITECTURE SHEET TITLE PLUMBING PLAN 'R CE I ON P, nECF!VED 5HEET (GITY OF 1 iiii .V1LA APR 17 2019 PERMIT CENTER PLUMBING GENERAL NOTES 1. CONTRACTOR SHALL VERIFY FIELD CONDITIONS AND MAKE ADJUSTMENTS AT NO ADDITIONAL COST TO OWNER. 2. THE CONTRACTOR SHALL OBTAIN A COPY OF THE LANDLORD'S TENANT CRITERIA MANUAL. TENANT CRITERIA MANUAL REQUIREMENTS SHALL BE INCLUDED IN THIS CONTRACT. CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING W/ LANDLORD REQ'MTS. AT NO EXTRA COST TO THE OWNER. 3. CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFICATION OF ALL EXISTING CONDITIONS PRIOR TO SUBMITTING HIS BID. NO ADDITIONAL COMPENSATION WILL BE MADE FOR ANY EXTRAS DUE THE CONTRACTOR'S FAILURE TO VISIT THE JOBSITE AND/OR PREDETERMINE ALL EXISTING CONDITIONS BEFORE SUBMITTING HIS SUB -BID. ANY DISCREPANCIES SHALL BE IMMEDIATELY REPORTED TO THE ARCHITECT FOR RESOLUTION. 4. ALL WORK SHALL BE COMPLETED IN ACCORDANCE WITH ALL APPLICABLE GOVERNMENT AND LOCAL CODES. 5. PROVIDE ACCESS PANELS AS NEEDED TO ACCESS VALVES, EQUIPMENT, ETC. LOCATED ABOVE GYP. BD. CEILINGS. 6. PROVIDE TEMPORARY COVERS, CAPS, OR PLUGS IN SANITARY SEWER SYSTEM THROUGHOUT CONSTRUCTION. RAG WADS, DUCT TAPE OR OTHER MAKE SHIFT CAPS ARE NOT ACCEPTABLE. UPON COMPLETION OF CONSTRUCTION, COMPLETELY TRUCTION, COMPLETELY REMOVE ANY AND ALL OBSTRUCTIONS INSIDE THE DWV SYSTEM, NEW AND EXISTING LINES, BY SNAKING, RODING, OR JETTING THE SYTEM IMMEDIATELY PRIOR TO THE PROJECT TURNOVER TO THE OWNER (TENANT). 7. THE CONTRACTOR SHALL PROVIDE A MIXING VALVES SET AT 110- F. FOR ALL LAVATORIES AND HAND SINKS. MIXING VALVE SHALL BE POWERS E480 OR APPROVED. 8. PIPE RELIEF CATCH PAN FROM WATER HEATER TO MOP SINK. MAINTAIN A 2" MINIMUM AIR GAP. PROVIDE A CATCH PAN UNDER WATER HEATER AND EXPANSION TANK. 9, CONNECT NEW SANITARY SEWER SYSTEM TO EXISTING SANITARY SEWER OF EQUAL OR GREATER SIZE. VERIFY EXACT LOCATION, SIZE, AND INVERT ELEVATION OF EXISTING SANITARY SEWER PRIOR TO STARTING WORK. FIELD ADJUST NEW INTERIOR SANITARY ROUTING AS NECESSARY TO CONNECT TO EXISTING SANITARY SEWER WHILE MAINTAINING REQUIRED SLOPE. 10. INSTALL NEW WATTS 1/2" LF009 REDUCED PRESSURE BACKFLOW DEVICE FOR THE BEVERAGE DISPENSER AND TEA BREWER. 11. REFER TO ARCHITECTURAL PLANS FOR PLUMBING DEMOLITION WORK, IF ANY, AND NOTES. 12. SEE RESTAURANT EQUIPMENT SCHEDULE ON THE ARCHITECTURAL PLANS FOR EQUIPMENT PROVIDED BY OTHERS. THIS CONTRACTOR SHALL CONNECT WASTE, VENT, AND WATER TO EQUIPMENT FURNISHED BY OTHERS AND THIS CONTRACTOR SHALL INSTALL FAUCETS AND MISC. FITTINGS FOR A COMPLETE INSTALLATION. 13, SEE ALL OTHER DRAWINGS IN THIS SET AND SPECIFICATIONS FOR WORK REQUIRED OR CLARIFICATIONS FOR NECESSARY WORK 14. CONNECT NEW DOMESTIC WATER TO EXISTING LINE- VEIFY LOCATION AND REQUIREMENTS. 15. VALVES SHOWN SHALL BE BALL VALVES, OR EQUAL, RATED FOR 125 PSI WORKING PRESSURE. 16. ALL NEW WATER PIPE ABOVE GRADE SHALL BE TYPE "L" COPPER PIPE AND FITTINGS. PEX PIPING MAY BE USED IN LIEU OF COPPER IF ALLOWED BY LOCAL CODES. 17. ALL NEW HOT COLD AND RECIRCULATING WATER PIPING SHALL BE INSULATED WITH 1" THICK FIBERGLASS INSULATION, ASJ, VAPOR BARRIER. 18. ALL EXPOSED PIPING TO PLUMBING FIXTURES SHALL BE CHROME PLATED. STOPS SHALL BE PROVIDED WITH REMOVABLE TYPE HANDLES. 19. PROVIDE 12" LONG AIR CHAMBERS AT EACH PLUMBING FIXTURE, OR OTHER CODE APPROVED DEVICE. 20. EXTEND PLUMBING VENT UP THRU ROOF TO APPROVED VENT TERMINATION. LOCATE MINIMUM OF 10 FEET FROM ANY O.A. INTAKE AT THE ROOFTOP UNITS. 21, EXTEND WASTE FROM 3 COMPARTMENT SINK TO DRAIN IN ACCORDANCE WITH LOCAL CODE REQUIREMENTS. 22. ICE/DRINK DISPENSER BACKFLOW PREVENTOR MAY REQUIRE SEPERATE PERMIT AND TEST CERTIFICATE 23, REMOVE ALL EXISTING PLUMBING NOT NOTED TO REMAIN AND/OR NOT REQUIRED BY NEW WORK. EXISTING PLUMBING ITEMS THAT ARE TO REMAIN SHALL BE REROUTED AND RECONNECTED AS REQUIRED BY NEW TENANT SPACE DESIGNS. Ito 01���101 •- • - I���I��I i EXISTI• - I���I��I I�I���I�I I•��I��I CI•I I���I��I 01���101 DISHIIIA5HER EXI5TIW3 TO REMAIN l0000000 01���101 -- - 51w, EXISTHS fo REMAIN 1"MI1MMM101 FAUCET EX15TINZ A I•I���I�I I���I��I 01►1���1 I - -- -• r • - r I���I��I 101►-� �101 • • � I���I��I �I��I �I►x.��101 r- � - i� • - •r• I���I��I I�1�►.��101 MIMI �immmi�I ®I ►n��101: - - - - I�®®I��i r - �ImmmI I �I►a���101 I®®�I•�I �I���I�I I�I•�I��I 1 INDIRECT WASTE �I�� ICI I� �I�I•I PLUMBING LEGEND — — COLD WATER PIPING ---- HOT WATER PIPING —F— FILTERED WATER PIPING EXISTING SANITARY SEWER PIPING WASTE/SANITARY UNDER FLOOR — -- VENT PIPING —G — GAS PIPING —O FLOOR CLEANOUT --II WALL CLEANOUT ® FLOOR DRAIN -0� GATE VALVE -Cf4-- BALANCING COCK fl- CHECK VALVE -- BALL VALVE f HB HOSE BIBB REMARKS: PLUMBING FIXTURE SCHEDULE MARK ITEM MANUFACTURER MODEL NO UTILITIES REMARKS CVV H VT WC WATER CLOSET EXISTING 1" - 3" 2" LAV LAVATORY EXISTING 1/2" 1/2" 1 1/2" 1 1/4" UR URINAL EXISTING 3/4" - 2" 2" FS FLOOR SINK WADE WADE W-9140 W/ 3/4" GRATE - - 2" 2" PROVIDE SLOAN FLUSH VALVE FD FLOOR DRAIN WADE WADE W-1100 W N. BRONZE STRNR - - 2" 2" PROVIDE TRAP PRIMERS WATER HEATER EXISTING 1" 1" REVIEIM CODE CON . APPRt APR 2, City of I BUILDING All concepts, designs, arrangements, and data indicated on these documents are the property of Cz. A. Miller Architecture and were created, evolved, and developed for use on, and in connection with the specified project. None of such ideas, designs, arrangements, or data shall be used by, or disclosed to any person, firm, or corporation for any purpose whatsoever without permission of Cs. A. Miller Architecture. M 14 mw3p SA NIILL,�Fl J J J J J J J J J J J J J 141 DEL PRADO LAKE OSWEGO, OREGON 97035 503.636.7979 503.636.9898 — FAX glen@gomlllerorchitecture.com CONSULTANTS MATHEWS CONSULTING GENERAL CONTRACTOR: EM PRECISION PUYALLUP, WASHINGTON REGISTERED ARC4IT T? GLEN A. Afl1, LE ? STATE ©E ASIIINSTON TRAPPER'S SUSHI T.I. SOUTHCENTER MALL TUKWILA, WASHINGTON J J J J J J J J J J J J J OWNER: TRAPPER'S SUSHI CO. P PA!�p j� SUSHI Co OVII/lq LANDLORD/ADDENDUM#1 wirw18 GORP/OWNER REVIEW MARK DATE DESCRIPTION JOB NO.: FILE: BY: PLAN CHECK NO. PERMIT NO. DATE: copyright 2013 GA MILLER ARCHITECTURE SHEET TITLE :_Rtt M B I N G DETAILS LIANCE 1 ED 2019 kwila SION nECEIVEf) 5HEET CelTy OF TUIGNVILA An 1.7 N19 pERMIT CENTER i H --- R-VALUE OF WALK --IN COOLERS COOLERS - MINIMUM OF R-25 FREEZERS - MINIMUM OF R-32 INCLUDES FLOORS, WALLS AND CEILINGS FREEZERS FLOORS - MINIMUM OF R-28 i ■1 ■ -H R ROOF / REMOTE LOCATIONII f SEE ARCHITECTS / ENGINEERS DRAWINGS 59 60 61 62 GENERAL NOTES IT SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR ND ALL SUB -CONTRACTORS TO RIFY THE ACTUAL SPACE AND MECHANICAL REQUIREMENTS OF ALL ITEMS SHOWN AS FUTURE, NI�, SUPPLIED BY "OTHERS", ETC., ITH THE OWNER PRIOR TO ROUGH -IN AND CONNECTION. THE GENERAL CONTRACTOR SHALL IMMEDIATELY INFORM CMA RESIIAURANT ��__ SUPPLY & DESI NO HE OWNER OF ANY RED LINES, CORRECTIONS, ETC., ON THE PERMIT PLANS AND OF ANY INSPECTION CORRECTIONS REQUESTED CONCERNING T E E DRAWINGS OR EQUIPMENT AS LISTED FOR THIS PROJECT. THE GENERAL CONTRACTOR SHALL PROPERLY SEAL ALL WALL AND FLOOR PENETRATIONS AFTE T1E INSTALLATION OF RELATED EQUIPMENT AND FURNISHINGS ITEMS. IT SHALL BE NOTED BY THE GENERAL CONTRACTOR AND ALL SO CONTRACTORS THAT THIS E OF PLANS AND THE INFORMATION n/ CONTAINED WITHIN IN NO WAY RELIEVES SAID PARTIES OF THEIR RESONSIBILITY TO INVESTIGA-E ND COMPLY WITH ALL APPLICABLE ■ CODES AND ORDINANCES, AND TO PERFORM ALL WORK TO THE H GHEST STANDARDS. uhi i A i ry : IRE -RATED SHAFTS FOR EXHAUST Ai 1 vvi- a_LEE — --- - 6� ou�� A� wv R tw1 Fru , rti� �. ��� , t L o ,A� _ _ - DUCTS. ' IT SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR �� N ,� TO PROVIDE WEATHER PR T CTION FOR ALL ROOF AND ALL WALL SUITABLE WALL BACKING AS SHOWN ON THESE PLANS AND AS REQUIRED BY THE OWNER SHALL BE PROVIDED AND INSTALLED BY THE GENERAL CONTRACTOR. N 1 VERIFY EQUIPMENT REQUIREMENTS WITH FINAL EQUIPMENT SELECTIONS r UNPUBLISHED WORK QC 2018 CMA. INC. 00 00 00 o vJ C s— 0 i ai i cn Y d. o CIO CID (L_ � N r can ice. N V �J U z Fry] 1-5 U CL :D C/) t n 'm m Z Y ;, �E U D N_ CrW C Z � W EIE z 0 0�/ z W REVIEWED FOR ODE COmPLIANC APPROVED APR 22 2019 City of TUkwila BUILDING DIVISIO Date: 11-27-2018 JIG WINTER Scale: 114"=V-0" Project #: 1489 CIT11e;ilIE Tui 1720 VILA 9 PERMIT CENTER EQUIPMENT-1- i. THE. ELECTRICAL CONTRACTOR SHALL SUPPLY AND INSTALL SEAL -TITS FLEX CONDUIT TO ALL FOOD SERVICE IN DAMP AREAS, I.E., SCULLERY, BAR ROOF, ETC. FLEX CONNECTIONS AT ALL FANS ON THE ROOF SHALL BE OF EXTRA LENGTH TO ALLOW FULL FAN REMOVAL FOR THE EASE OF CLEANING. 2. THE ELECTRICAL CONTRACTOR SHALL PROVIDE FUSED DISCONNECTS FOR EQUIPMENT HOOK-UPS AS REQUIRED BY CODE AND LABELING. 3. THE ELECTRICAL CONTRACTOR SHALL PROVIDE DISCONNECTS IN A CONVENIENT ACCESSIBLE LOCATION AT AT THE POWER BOX FOR EACH ICE MACHINE HEAD. 5. THE ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL AVAPOR-PROOF SWITCH AT EACH BLOWER COIL IN THE WALK-IN COOLER ITEM 16 . B. THE ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL A 48" MINIMUM CORD AND PLUG FOR EACH PIECE OF EQUIPMENT SO NOTED. USE 90 ELBOW OUT OF UNIT_ 10. THE ELECTRICAL CONTRACTOR SHALL PROVIDE FOR HOOK-UP OF A THERMOSTAT, SOLENOID, BLOWER COIL AND COMPRESSOR FOR EACH REFRIGERATED UNIT. MAGNETIC STARTERS AND OR THERMAL / PROTECTORS SHALL BE INCLUDED AS NECESSARY. 11. THE ELECTRICAL CONTRACTOR SHALL PROVIDE 1" CONDUIT AND JUNCTION BOXES AT EACH CASH REGISTER TERMINAL SO AS TO INTERCONNECT ALL UNITS TO EACH OTHER AND TO THE CENTRAL PROCESSING TERMINAL. CONSULT WITH THE OWNER'S REPRESENTATIVE FOR EXACT LOCATIONS OF ALL TIE-IN UNITS. 13. THE PLUMBING CONTRACTOR SHALL PROVIDE AND INSTALL ALL DRAIN LINES FROM WALK-IN BLOWER COILS TO FLOOR SINKS. HEAT TAPE SHALL BE PROVIDED AND WRAPPED AT ALL DRAIN LINES SUBJECT TO THE POSSIBILITY OF FREEZING, SUPPLIED AND INSTALLED BY ELECTRICAL CONTRACTOR. 14. ALL DRAIN LINES FROM EQUIPMENT REQUIRING CONDENSATION REMOVAL SHALL BE DONE IN COPPER 15. IT SHALL BE THE RESPONSIBILITY OF "OTHERS" TO INTERCONNECT THE HOOD FIRE PROTECTION SYSTEMS TO THE BUILDING FIRE DETECTION UNITS AS REQUIRED. 9 SWITCH. MCOTORSI, COMPRESSORS,HALL SUPPLY CONDENSERS, ETC.) ARLL TO SE ARATECH PIECEWEATHER- ROTOEOCTEDODI DISCONNECTET 20. PLUMBING CONTRACTOR SHALL SUPPLY AND INSTALL ANTI -SIPHON VALVE ASSEMBLIES FOR SODA DISPENSING SYSTEM. 22. IT SHALL BE THE RESPONSIBILITY OF THE PLUMBING AND ELECTRICAL CONTRACTORS TO MAKE ALL REQUIRED WATER, GAS, DRAIN AND ELECTRICAL FINAL CONNECTIONS FOR ALL MAKE-UP AIR SYSTEM UNITS. 23. IT SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO INSTALL ALL OWNER SUPPLIED COMPUTER/COMMUNICATIONS CABLES AS PER OWNERS DIRECTION. 24. IT SHALL BE THE RESPONSIBILITY OF PLUMBING CONTRACTOR TO COMPLY WITH ALL LOCAL CODES CONCERNING GAS VALVE REGULATOR VENTING. 25. ELECTRICAL CONTRACTOR SHALL PROVIDE A INDIVIDUAL DISCONNECT BOX FOR EACH PIECE OF ROOF TOP ELECTRICALLY POWERED EQUIPMENT. 26. THE GENERAL CONTRACTOR SHALL PHOTOGRAPH ALL WALLS CONTAINING BACKING PRIOR TO SHEETROCK/FRP INSTALLATION- 27. THE PLUMBING CONTRACTOR SHALL PROVIDE CLEANOUTS AT 1ST ELBOW ON EACH WALK-IN BLOWER COIL DRAIN. 29. THE PLUMBING CONTRACTOR SHALL SUPPLY AND INSTALL WATER LINE BACK CHECK VALVES AS REQUIRED PER CODE. 30. THE ELECTRICAL CONTRACTOR SHALL PROVIDE INTERCONNECT SWITCHING BETWEEN THE KITCHEN EXHAUST HOOD EXHAUST FANS AND THE KITCHEN MAKE-UP AIR SYSTEMS AS REQUIRED PER LOCAL CODE AND AUTHORITIES. 31. COMMUNICATIONS CABLES ARE SUPPLIED BY OWNER AND INSTALLED BY ELECTRICAL CONTACTOR. 32, ELECTRICAL AND MECHANICAL CONTRACTOR TO VERIFY REQUIREMENTS OF OWNER PROVIDED EQUIPMENT. 35. PRESSURE REGULATORS FOR GAS COOKING EQUIPMENT SUPPLIED BY KEC AND INSTALLED PER CODE AND MANUFACTURER'S SPECIFICATIONS BY PLUMBING CONTRACTOR. 36. ELECTRICAL CONTRACTOR SHALL PROVIDE INTER CONNECT FOR FREEZER COIL & TIMECLOCK CIRCUIT DEFROST SYSTEM. o 7 I SUPPLIER r DESCRIPTION I - 7_ O' ELECTRICAL PLUMBING -- GAS -- ---- ----- -------------- " NOTES m Y � W o � o '. > laJ U S U W U ! 2 ! ii MOP SINK EXISTING 10 FAUCET FAUCET EXISTING 10 REMAIN REMAIN I ---- .------- ---------- _ 3 I 1 CHEMICAL SHELF MOP hANGER EXISTING TO REMAIN j 4 5 1 _ _ 1 _ WATER HEATER EXISTING TO 4 'STAINLESS STEEL CORNER GUARD REMAIN', _ 6 1 i 1 DRY STORAGE SHELVING - ---- - 7 j 1 WALK-bN COOLER FREEZER EXISTING TO REMAIN 8 BLOWEF COIL EXISTING TO REMAIN 9 NEAT TAPE FOR DRAIN LINE _ EXISTING TO REMAIN _ 10 111_' [IF - 1 j COMPRESSOR EXISTING 1 SHELVING EXISTING TO REMAIN REMAIN _ _I ----------------------------------- ' 12 _1 BLOWER COIL EXISTING TO REMAIN ''. 13 1 1 COMPRESSOR EXISTING TO REMAIN 14 -': _ 1 1 SHELVING EXISTING TO REMAIN 15 i I WALK-IN KEG COOLER 3.0 115_ 1 JBOX, _ FOR LIGHTS 16 17 1 J BLOWER COIL _ _ (- 115 1 JBOX 1 3 4 ;INDIRECT WASTE NOTE Ik36 3 _ 1 KEG 4.3 4.3 208 3 JBOX 18 ill RACKING 1 KEG RACKING I ( 19 ;� 1 SHELVING 20 '', i SHELVING 21 j SPARE NUMBER 32 _ _ 1 SPARE NUMBER 23 1 1 SPARE NUMBER 24 SPARE NUMBER 25 BAG N BOX RACK - 26 _�_ !, _ 1 BULK CO2 TANK - NOTE 4'18 27 11 2 WORK TABLE _ 78 r® 1 WALL SHELVING _ 29 '_ _ 3 RICE WARMER ON MOBILE TABLE 0.8 115 1 EGO ____ NEMA 5-15P 30 3 COUNTER TOP REFRIGERATED UNIT 3.0 115 1 DCO 1 NEMA 5-15P 31 SPARE NUMBER -_ ---- 32 Y� 4 HAND SINK _ -1 2 DIRECT WASTE _ 34 4 AND TOWEL DISPERSER—- 35 CLEAN DISH VING 36 1 SOILED TABLE WITH PRE -RINSE SINK EXISTING TO REMAIN 37 i !FAUCET EXISTING TO REMAIN�I 38 ! 1 GREASE INTERCEPTOR EXISTING TO REMAIN _ 39 RACK SORT SHELF EXISTING TO REMAIN _ 40 SPARE NUMBER - T 1 DISHWASHER EXISTING TO REMAIN 11 - 42 1 1 ; CLEAN DISH TABLE N1 3 COMP SINK EXISTING TO REMAIN _ 43 i -- 1 WALL MOUNTED POT RACK EXISTING 10 REMAIN - - -- _ -- _ --- ---- I 44 _ i, PREP SINK EXISTING TO REMAIN _ 45 ! t I FAUCET EXISTING FO REMAIN 46 SPARE NUMBER I 47 SPARE NUMBER - -- - 4S __ ;SPARE NUMBER _ 49 13 1 ;WALL SHELF _ 50 SPARE NUMBER 51 52 '..,,, _ _ -------- _ _ i SPARE NUMBER-- 1 SPARE NUMBER ---- 53 j _ ------------------------- _� SPARE NUMBER ------ ---- -------------- _ - ----------- -� 54 SPARE NUMBER .._ 55 ''� 1 i PAN TOP REFRIGERATOR - 4.4 115 1 RICO FIRMA 5-15P I 56 I® I 2 1 WALL SHELF 57 j _ POINT OF SALE PRINTER j 3.0 115 1 DCO� I ;DEDICATED ISOLATED, VERIFY REQUIREMENTS OF OWNER PROVIDED EQUIPMENT _58 59 : i ! CLASS I EXHAUST HOOD 1 I EXHAUST FAN X X X X 1 X JBOX 1 JBOF I FOR LIGHTS 60 EXHAUST DUCTWORK _ 61 ®; t MAKE-UP AIR FAN HEATER X 208 X JBOX X X NOTE # 22 25 62 1 MAKE-UP AIR DUCTWORK 63 _ i STAINLESS STEEL WALL FLASHING _ 164 j_ 1 (FIRE SUPPRESSION SYSTEM _ NOTE 15 65 - 2_ TABLE 3 1 FRYER 3 4 05,000 6/ i REFRIGERATED EQUIPMENT STAND 3..0 _ 115 1 DCO '', NEMA 5-15P j 68 1 GRIDDLE 3.4 85,000-J' : 69 ___ 1 ,OPEN BURNERS _ 3 4 50,000 70 ;TABLE __ _ _ 71 _-I 2 RICE COOKER_____ - 1 2 34,0 00 72 __ 73 ( 74 1 7 QUICK DISCONNECT _,I SPARE NUMBER SPARE NUMBER GAS LINE _ - --- - _j - ---'i ----- 75 ',..� SPARE NUMBER _ 76 ' SPARE NUMBER _ ------- 77 -78 ,, - ----- ---- SPARE ----;i SPARE NUMBER NUMBER ------- - -- -------_-- 1' 79 cm I STAINLESS STEEL ALL CAP SHELF 1 WORHE - 2_VWIITH DOUBLEDOVEERSHEAVER - X- 8� ® 2 ABL 5 BOX: 82 1 SPARE NUMBER I NEMA 5 15P C 83 : - - 37 MICROWAVE OVEN_ _ 13.0 115 1 DCO ' NEMA 5-15P 84 4 PAN TOP R�EFRIGERA TOR 2.0 115 1 DCO - NEMA 5-15P 85 4 ':CUTTING BOARD , 86 =1 4 I CUTTING BOARD SUPPORT 87 SPARE NUMBER _ - 188 1 �� SPARE NUMBER -" 89 _j SPARE NUMBER- 90 1 SPARE NUMBER 91 � 1 DINING COUNTER 92 �4 1jSHI CASE _ _ 1.2 5 DCONEMA 5-15P 93 �' 1 PO COUNTER 94 ARE NUMBER - VERIFY REQUIREMENTS OF OWNER PROVIDED EQUIPMENT 95 ARE NUMBER _ 96 ARE NUMBER 97 ARE NUMBER 98 ARE NUMBER 99 1 ARE NUMBER-- ----- -- 1 100 _ 1 SPARE NUMBER 1 101 SPARE NUMBER 102 SPARE NUMBER- _ 1103 SPARE NUMBER- i 104 SPARE NUMBER _ 1 105 � 1E BAR TOP AND DIE WALL 06 1 1 HAND SINK 2' 2� 1 1 2 1 I DIRECT WASTE 107 2 1 DRAINBOARD WITH STORAGE_ - " INDIRECT WASTE 108 09 ICE BIN WITH COLD PLATE 1 1 DRINK MIX RAIL. - _ ---'-INDIRECT 1 2 WASTE NNHLCF WASTE 110 ® 1 'SODA GUN 3.0 115 1 DCO 1 2 NEMA 5-15P _ _ 1 DUMP SINK 2" �- 1 2 7' INDIRECT WASTE 2 ® DISHWASHER 12.0 208 X J©OX 3 4" 2 i _ 1 INDIRECT WASTE, VERIFY REQUIREMENTS WITH OWNER --, 3 114114 I - _ 1 1 DRAINER FOR TOP OF, DISHWASHER _------------------__- 1 I BACK BAR COUNTER & UPPER DISPLAY 1 INDIRECT WASTE 115 1r 1_5 I� 1 ;BACK BAR COOLER X I -POINT OF SALETERMINAL _ 5J 3.0 115 115 1 DCO._1 DCO 1 _ I NEMA S- P DEDICATED ISOLATED VERIFY REQUIREMENTS OF OWNER PROVIDED EQUIPMENT 117 1® 1 !BEER TAPS WITH RINSER 2 1 NEMA 5-15P INDIRECT WASTE 118 1® GLASS CHILLER 7.1 115 1 DCO _ I NEMA 5-15P 119 I SPARE NUMBER _.. - 1 120 I I SPARE NUMBER 121 I ' SPARE NUMBER 122 SPARE NUMBER - - 123 I SPARE NUMBER - ......" ....... 124 j I SPARE NUMBER 125 ® STAINLESS STEEL COUNTER WITH HAND SINK -""- 2 DIRECT WASTE 126 1�8 -�_ _ 1 ' FAUCET _ 1 SPARE NUMBER 1 2 1 2 - -"-- _75 128 3 CUP GLASS R CKS STORAGE - ry 129 ® 2 1 SODA DISPENSER 12.0 115 rDC 1 2 1 1 2 ! INDIRECT WASTE13Q ; 2 HOT WATER DISPENSER -- 5.4 5 2 NOTE # 8, EC TO PROVIDE CORD AND PLUG Lu 31_ _ 2 ACED TEA BREWER VERIFY _ REQUIREMENTS OF OWNER PROVIDED EQUIPMENT 132 _, i ICE MACHINE AND BIN_ 8 208 1 JBOX I 2 1 1 2 I s INDIRECT WASTE 133 ® UNDER---------------� 7 COUNTER REFRIGERATOR 2.5 115 1 DCO .NEMA 5-15P 13a I® 2 FOOD WARMER ____ 3-0 115 1 DCO _ _ 35 L136 ®_ 2 FOOD WARMER 8.0 5 DCO I SPARE NUMBER 137 I 1 STAINLESS STEEL COUNTER 138 CU GLASS RACTS-SIGRAGE 39 ® STAINLESS STEEL COUNTER 140 1 WALL SHELF 141 142 ® 1 STAINLESS STEEL COUNTER 1 WALL SHELF nrry APR 17 2019 PERL11T CENTER UNPUBLISHED WORK QC 2018 CMA. INC. 00 00 r c00 M i C 0 ^3 L (ll U � s cn M co Y c. c� n � N v 0 U Z v m a � � =Q a N � m F Z r� J Lwow- W J C) LLJ U W LLI G Cl- UJREVIEWED F z CODE COMPLIA LUI APPROVED H APR 22 2019 City Of TUICWiI BUILDING DIMS Date: 10-5-2018 JG WINTER Scale: 1 /4"=1'-0" Project #: 1489 K-2 JCE ON 0- Q715 + aPR6Oa _ � m 11 � rl E1� n p �I iryil I I 4" � IOIL 4 A -iOI V L_ -- ------ -- n 110 +12' ------ ""+12� H ROOF SEE ARCHITECTURAL OR MECHANICAL DRAWINGS CiDs ELECTRICAL LEGEND 115 VOLT DUPLEX OUTLET SDI 115 VOLT DCO, DEDICATED/ISOLATED ' 208V SPECIALTY OUTLET JUNCTION BOX ® COMMUNICATIONS VERIFY AN D REQU REMEN SWITH OWNER SPEC'S ON/OFF SWITCH I p LIGHT FIXTURE BY K.E.C. AND I ELECTRICAL CONTRACTOR IJ STALLED BY VERIFY EQUIPMENT REQUIREMENTS I WITH FINA UEQPMENT SELECTIONS GFCI RECEPTACLES SHALL BE PASS & SEYM UR NO. 2095-W ELECTRICAL NOTES I INSTALL STAINLESS STEEL TLET AND RECEPTACLE 1. THE CONTRACTOR SHALL PROVIDE ANq COVERS IN SERVICE AREAS. 4. THE ELECTRICAL CONTRACTOR SHALL ROVIDE AND INSTALL HEAT APE ON DRAIN LINES IN DANGER OF FREEZING. 5. THE ELECTRICAL CONNECTIONS, SPECI ARE FOR FOOD SERVICE EQUIPMENT ONLY. ICATIONS AND DIMENSIONS HOWN ON THESE PLANS13 SEE THE ARCHITECT' PLAN SET FOR ALL OTHER ELECTRICAL REQUIREMENTS FOR THIS PROJECT. UJ 6. ALL ELECTRICAL ROUGH -IN WORK AND ALL FINAL CONNED IO R ALL ITEMS SHOWN AND SPECIFIED ON THESE PLANS BY CMA SHALL BE PERFORME T E ELECTRICAL V J CONTRACTOR. 7, UNLESS OTHERWISE SPECIFIED IN THESE THE RESPONSIBILITY PLANS OR OTHER WRI T N CONTRACTS, IT SHALL BE OF THE ELECTRICAL CONTRACTOR TO PR VI E ALL ELECTRICAL -TYPE MATERIALS INCLUDING WIRING, SWITCH S, DISCONNECTS, FLEX, C ROUT, CONTACTORS, TRANSFORMERS, THERMAL OVERLOAD ROTECTORS, MAGNETIC S ARTERS, ELECTRICAL PANELS, CORDS, PLUGS, COVERS, ETC. 9. ALL DIMENSIONS SHOWN ARE FROM GRID LINES, FINISHED W L OR FINISHED FLOORS TO W CENTER LINE OF ELECTRICAL OUTLET BOXES. HEIGHTS ARE 0 TO BE TAKEN FROM CURBS OR PLATFORMS ----- -- - - FROUGH-IN LOCATION AND TYPE _ __-- --- - - --- -'--- OF CONNECTION ONLY. THE ELECTRICAL CONTRACTOR SHAL ROVIDE CIRCUITS AND CONDUIT RUNS AS PER GOOD PRACTICE AND C DE. 11. IT SHALL BE THE RESPONSIBILITY OF _SWITCHING HE ELECTRICAL CO i ACTOR TO PROVIDE INTERCONNECT HOOD EXHAUST FANS AND THE KITCHEN MAKE UP AIR AND AUTHORITIES. C% BETWEEN THE KITCHEN EXHAUST SYSTEMS AS REQUIRED PER LOCAL CODE 12. IT SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO PROVIDE ELECTRICAL CONTACTORS ON ALL ELECTRICAL OUTLET, JUNCTION BOXES, ETC. LOCATED UNDER ANY CLASS I EXHAUST HOOD SO AS TO DISCONNECT UPON ACTIVATION OF THE FIRE SUPPRESSION SYSTEM. 14. THE ELECTRICAL CONTRACTOR SHALL PROVIDE FUSED DISCONNECTS FOR EQUIPMENT HOOK-UPS AS REQUIRED BY CODE AND LABELING. 15. ALL GFCI RECEPTACLES SHALL BE LOCATED ' IN AN ASSESSABLE LOCATION FOR STATIONARY EQUIPMENT. UNPUBLISHED WORK C) i. • 1 � •• • fib:ii � I � 1 OMPLIANCE ��• 11 j" CFrtf Tukwila ALWING DIVISION UJ I • - m L) �1 t �J ii 1 dil — 132 +22' ; 33 --i _ L a i I FS emu. i� FLR(1212 El +22 -,) +4a" 33s i +22'* 12: n +24" 12f N' +72",3 � II I November 30, 2018 I -H 0 'y I 4" DIAMETER UNDERGROUND PVC FLR FLR BEVERAGE CONDUIT FOR REMOTE SODA DISPENSING SYSTEM, STUB UP' +8" OFD w/ 24" RADIUS ELBOWS (TYP. EA END) / �� —. (�_._ _ ____..------- i _H I REMOTE SEE ARCHITECTURAL DRAWINGS 38 �' ROOF SEE ARCHITECTURAL DRAWINGS fit PLUMBING NOTES 1. IT IS THE GENERAL CONTRACTORS RESPONSIBILITY TO SIZE, SUPPLY AND IN L A GREASE INTERCEPTOR/TRAP IF ONE IS REQUIRED. 2. ALL FIRE PROTECTION SYSTEM GAS SHUTAFF VALVES SHALL 'LIED BY THE OWNER AND INSTALLED BY PLUMBING CONTRACTOR. 3. THE PLUMBING CONNECTIONS, SPECIFICATIONS AND DIMENSIONS SHOWI N THESE PLANS ARE FOR FOOD SERVICE EQUIPMENT ONLY. SEE) ARCHITECT'S PLAN SET FO ALL OTHER PLUMBING REQUIREMENTS FOR THIS PROJECT. 4. ALL PLUMBING ROUGH -IN WORK AND FINAL CONNECTIOINS FOR ALL II MS S WIN AND SPECIFIED ON THESE PLANS BY CMA REST.URANT SUPPLY & DESIGN SHALL E PERFORMED BY THE PLUMBING CONTRACTOR. 6. UNLESS OTHERWISE SPECIFIED IN THESE PLANS OR OTHER WRITTEN C NTRAC S, IT SHALL BE THE RESPONSIBILITY OF THE PLUMBING COITRACTOR TO PROVIDE ALL NG-TYPE MATERIALS INCLUDING VALVES, TRAPS, LIN STRAINERS, FLOOR SINK COVE , PRESSURE REGULATORS, SIPHON BREAKERS, ETC. 7,IT SHALL BE THE RESPONSIBILITY OF THE CiE.NERAL CONTRACTOR TO VERI THAT THE LOCATIONS FOR ALL MECHANICAL REQUIRE II ENTS WHICH REQUIRE FLOOR NETRATIONS DO NOT CONFLICT WITH STRUCTURAL MEMBERS' IN THE FLOOR. 8. THE GENERAL CONTRACTOR SHALL SUPERiE THE LOCATION OF ALL FL R DRAINS ON THE JOB SITE SO AS TO ENSURE THE BEST SL,PE POSSIBLE OF THE SURR NDING FLOOR TO THESE DRAINS. 9. ALL DRAIN LINES FROM EQUIPMENT REQUIRI� G CONDENSATION REMOVAL HALL BE RUN IN COPPER. 10. PLUMBING CONTRACTOR TO SUPPLY WATER PRESSURE REDUCING VALV EACH DISHWASHER AND GLASS WASHER, PLUMBING LEGEND O CW-COLD WATER � a E 0 CW-COLD WATER -FILTERED HW-HOT WATER ® CLOSED DRAIN - DIRECT WASTE 12 X 12 FLOOR SINK - INDIREC�WASTE NATURAL GAS I — FLOOR DRAIN nEGr_i."'ED CITY OF ii-K ILA APR 1 2'1,9 O - PERMIT CENTER N I r� VERIFY EQUIPMENT REQUIREMENTS WITH FINAL EQUIPMENT SELECTIONS w � r UNPUBLISHED WORK . �II� vl it IJLITA) • I�,JIB �ix� • • • -r c n „ IIIII I REVISIONS TTnnTI TAWn7?AfATTn AT - T-Jh JLQA' 09,1�9 MAX. EXHAUST PLENUM TOTAL HOOD CONFIG. RISER(S) END TO HOOD TAG MODEL LENGTH COOKING SUPPLY HOOD TOTAL EXH. CFM WIDTH LENG. HEIGHT DIA. CFM VEL. S.P. NO, TEMP. CFM CONSTRUCTION END ROW 5424 600 430 SS 1 ND-2-PSP-F 13' 6' Deg. 3172 4' 18' 3172 1795 -1,046' 2854 Where Exposed ALONE ALONE wrinn rv)PnR1,fATTnAT PATENT NUMBERS AC-PSP (United States) - US Patent 7963830 B2 AC-PSP Watt (Canada) - CA Patent 2820509 AC-PSP Island (Canada) - CA Patent 2520330 FILTERS) LIGHTS) UTILITY CABINET(S) FIRE HOOD HOOD TAG EFFICIENCY @ 7 WIRE FIRE SYSTEM ELECTRICAL SWITCHES SYSTEM TYPE SIZE MODEL # QUANTITY NO. TYPE QTY.HEIGHT LENGTH MICRONS QTY. TYPE GUARD LOCATION SIZE PIPING WGHT WGHT 857 See Filter 1 Light 917 1 Captrate Solo Fitter 10 20' 16` Spec. 3 12' x 12' LED NO Left 12'x54'x24' Ansut R102 3.0/3.0 DCV-1111 YES LBS 1 Fan LTnnn nL1TTn ATc HOOD NO, TAG OPTION RIGHT QUARTER END PANEL 23' Top Width, 0' Bottom Width, 23' High 430 SS INSULATION FOR BACK OF HOOD 1 LEFT VERTICAL END PANEL 27' Top Width, 21' Bottom Width, 80' High Insulated 430 SS SENSOR -CV F1M]n E1nE)A'PL'T) C'TTDDTV E)T1PATTTa.f1Vl HOOD NO. TAG PUS. LENGTH WIDTH HEIGHT TYPE RISER(S) WIDTH LENG. DIA. CFM S.P. 1 Front 174' 18' 6' MUA 12' 28' 713 0.192' MUA 12' 28' 713 0.192' MUA 12' 28' 713 0.192' MUA 12' 28' 713 0.192' 1' LAYER OF INSULATION FACTORY INSTALLED IN INTERNAL BACK STANDOFF. MEETS 0 INCH REQUIREMENTS FOR CLEARANCE TO COMBUSTIBLE SURFACES. 3' 1 018' i U.L. Listed 12' x 12' Recessed LED Light 54' Utility Cabine 28' 28' 28' O 12— ------ ---- ----- 12— ------ ------- 12— ------ ----'— I 12'— ------ ------- 18' ICI ®0 0 81' 81' 21 3 4' -- - 43 1/2' -�- 43 1/2'Ij-- 43 1/2' --� 12' 13' 6'Nom./13' 6.00'OD 14-6.00' Overall Length PLAN VIEW - Hood #1 13' 6.00" LONG 5424ND-2-PSP-F NOTES Additional hanging angles provided for hoods 12' and longer. HOOD CORNER FULL LENGTH HANGING ANGLE HANGING ANGLE 1/2' - 13 TPI GRADE 5 (MINIMUM) (HARDWARE BY INSTALLER) 1/2' - 13 TPI GRADE 5 (MINIMUM) (HARDWARE BY INSTALLER) STEEL HEX NUTS STEEL HEX NUTS 1/2' GRADE 5 1/2' GRADE 5 (MINIMUM) STEEL (MINIMUM) STEEL FLAT WASHER FLAT WASHER 1/2' - 13 TPI 1/2' - 13 TPI GRADE 5 (MINIMUM) GRADE 5 (MINIMUM) STEEL ALL -THREAD STEEL ALL -THREAD 1/2' - 13 TPI GRADE 5 (MINIMUM) 1/2' - 13 TPI STEEL HEX NUT GRADE 5 (MINIMUM) STEEL HEX NUT FULL LENGTH 1/2' GRADE 5 HGDD CORNER HANGING ANGLE (MINIMUM) STEEL HANGING ANGLE 1/2' GRADE 5 (WEIGHT BEARING FLAT WASHER (WEIGHT BEARING (MINIMUM) STEEL ANCHOR POINT ANCHOR POINT FLAT WASHER FOR HOOD) FOR HOOD) 1/2' GRADE 5 (MINIMUM) STEEL FLAT WASHER 1/2' GRADE 5 (MINIMUM> STEEL 1/2' - 13 TPI TPI FLAT WASHER GRADE 5 1/2' - 13 TPI STEEL HEX NUTS GRADE 5 (MINIMUM) STEEL HEX NUT ASSEMBLY INSTRUCTI❑NS ASSEMBLY INSTRUCTI❑NS SUPPLY PLENUM 1/2' - 13 TPI HANGING ANGLE GRADE 5 (HARDWARE BY INSTALLER) STEEL HEX NUTS(MINIMUM) 3/2' OR 5 (MINIMUM) STEEL FLAT WASHER 1/2' - 13 TPI GRADE 5 (MINIMUM) STEEL ALL -THREAD 1/2' - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUT SUPPLY PLENUM HANGING ANGLE 1/2' GRADE 5 (WEIGHT BEARING (MINIMUM) STEEL ANCHOR POINT FLAT WASHER FOR SUPPLY PLENUM) 1/2' GRADE 5 (MINIMUM) STEEL FLAT WASHER 1/2' - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUT ASSEMBLY INSTRUCTI❑NS HANGING ANGLE MUST BE SUPPORTED WITH 1/2' - 13 TPI HANGING ANGLE MUST BE SUPPORTED WITH 1/2' - 13 TPI HANGING ANGLE MUST BE SUPPORTED WITH 1/2' - 13 TPI GRADE 5 (MINIMUM) ALL -THREAD. SANDWICH HANGING GRADE 5 (MINIMUM) ALL -THREAD. SANDWICH HANGING GRADE 5 (MINIMUM) ALL -THREAD. SANDWICH HANGING ANGLES AND CEILING ANCHOR POINTS WITH 1/2' GRADE 5 ANGLES AND CEILING ANCHOR P❑INTS WITH 1/2' GRADE 5 ANGLES AND CEILING ANCHOR POINTS WITH 1/2' GRADE 5 (MINIMUM) STEEL FLAT WASHERS AND 1/2' - 13 TPI (MINIMUM) STEEL FLAT WASHERS AND 1/2' - 13 TPI (MINIMUM) STEEL FLAT WASHERS AND 1/2' - 13 TPI GRADE 5 (MINIMUM) HEX NUTS AS SHOWN. MUST USE GRADE 5 (MINIMUM) HEX NUTS AS SHOWN. MUST USE GRADE 5 (MINIMUM) HEX NUTS AS SHOWN, MUST USE DOUBLED HEX NUT CONFIGURATION BENEATH HOOD HANGING DOUBLED HEX NUT C❑NFIGURATION ABOVE CEILING DOUBLED ANCHORS. HEX NUT CONFIGURATION ABOVE CEILING SINGLE HEX NUT BENEATH HANGING ANGLE IS ANGLES AND ABOVE CEILING ANCHORS. MAINTAIN 1/4' OF ANCHORS. SINGLE HEX NUT BENEATH HANGING ANGLE IS ACCEPTABLE FOR PSP HANGING ANGLES. MAINTAIN 1/4' OF EXPOSED THREADS BENEATH BOTTOM HEX NUT. TORQUE ACCEPTABLE FOR FULL LENGTH HANGING ANGLES. EXPOSED THREADS BENEATH BOTTOM HEX NUT, TORQUE ALL HEX NUTS TO 57 FT-LBS. MAINTAIN 1/4' OF EXPOSED THREADS BENEATH BOTTOM ALL HEX NUTS TO 57 FT-LBS. HEX NUT, TORQUE ALL HEX NUTS TO 57 FT-LBS, EXHAUST RISER HANGING ANGLE 20' CAPTRATE SOLI FILTER WITH HOOk 1' LAYER OF INSULATION FACTOR? INSTALLED IN 3' INTERNAL STANDOFF MEETS 0 INCH REQUIREMENTS FOF CLEARANCE TO COMBUSTIBLE SURFACES IT IS THE RESPONSIBILIT) OF THE ARCHITECT/OWNER TE ENSURE THAT THE HOOD CLEARANCE FROM LIMITED -COMBUSTIBLE AND COMBUSTIBLE MATERIALS IS IN COMPLIANCE WITS LOCAL CODE REQUIREMENTS GREASE DRAIP WITH REMOVABLE CUE RIGHT QUARTER END PANEL GAS CHASE CUTOU. (FOR GAS AND POWER LINES LEFT VERTICAL END PANEL WITH An DICT4nl c I rr' SPECIFICATI❑N: CAPTRATE° GREASE- STOP* SOLO FILTER THE CAPTRATE GREASE -STOP SOLO FILTER IS A SINGLE -STAGE FILTER FEATURING A UNIQUE S-BAFFLE DESIGN IN CONJUNCTION WITH A SLOTTED REAR BAFFLE DESIGN, TO DELIVER EXCEPTIONAL FILTRATION EFFICIENCY. FILTER IS STAINLESS STEEL CONSTRUCTION, AND SIZED TO FIT INTO STANDARD 2-INCH DEEP HOOD CHANNEL(S). UNITS SHALL INCLUDE STAINLESS STEEL HANDLES AND A FASTENING DEVICE TO SECURE THE TWO COMPONENTS WHEN ASSEMBLED. GREASE EXTRACTION EFFICIENCY PERFORMANCE SHALL REMOVE AT LEAST 75% OF GREASE PARTICLES FIVE MICRONS IN SIZE, AND 85% GREASE PARTICLES SEVEN MICRONS IN SIZE AND LARGER, WITH A CORRESPONDING PRESSURE DROP NOT TO EXCEED 1.0 INCHES OF WATER GAUGE, THE CAPTRATE GREASE -STOP SOLO WAS TESTED TO ASTM STANDARD ASTM F2519-05. EFFICIENCY VS. PARTICLE DIAMETER PRESSURE DROP VS. FLOW RATE Sao PARTICLE DIAMETER(wn) - CAPTRATE FILTERS ARE BUILT IN COMPLIANCE WITH:. NFPA #96 NSF STANDARD #2 UL STANDARD #1046 INT. MECH. CODE (IMC) ULC-S649 SECTION VIEW - MODEL 5424ND-2-PSP-F HOOD - 1 im soo iom ,sao FLOW RATE (cfin) LED LIGHT. 3K WARM FTACHING PLATES UPPLY RISER WITH 'OLUME DAMPER 23.5% OPEN STAINLESS STEEL PERFORATED PANEL REVIEV,4'ED FOR CODE =MPLIANCE APPROVED APR 22 2019 City of Tukwila BUILDING DIVISION nECEIVED CITY OF i'UK%YILA APR 17 2019 PERMIT CENTER d i QJ 4+ `L d u co S 00 031 C0 -P 0"", S s s 3 S -P :3 LLl /0 _J V J I— Q 00 Q k1D Ld DATE: 1 / 14/2019 DWG.#: 3679252 DRABY RTB - 85 SCALE: 3/4" = 1'-0" MASTER DRAWING MT F4411R,[o l REVISIONS MAX Aam 0 0 dl 132.0'ID•I I 24A0' I 24.00' I I I I I O i — — i -- -- --J-- — — O Hood # i Job # 3595328 Mode,, ND-2-PS P-F Sizes 54'x24' Length 13' (,� c„^„+ O 4T, 3K WARM lrl niz=. PLATES SER WITH AMPER III STAINLESS ERFORATED PANEL ZV CAPTRATE SOL[ FILTER WITH HOOK 1' LAYER OF INSULATION FACTORY INSTALLED IN 3' INTERNAL STANDOFF MEETS 0 INCH REQUIREMENTS FOR CLEARANCE TO COMBUSTIBLE SURFACES. IT IS THE RESPONSIBILITY OF THE ARCHITECT OWNER 10 ENSURE THAT THE HOOD CLEARANCE FIR O1 LIMITED-COMBUSTIDLE AND COMBUSTIBLE MATERIALS IS IN COMPLIANCE WITH LOCAL CODE REQUIREMENTS GREASE DRAD WITH REMOVABLE CUF RIGM QUARTER END PANEL GAS CHASE CUTOUT (FOR GAS AND POWER LINES: LEFT XERTnCaAMLrnEIARD P!TRd SECTION VIEW - MODEL 5424ND-2-PSP-F HOOD - #1 DUCT NOZZLE AND PLENUM SPRAY BAR LOCATION Job #: 3679252 Job Name: Trapper Sushi - Southcenter Matt RI System Size: ANSUL-3.0/3.0-MANIFOLD Total FP required: 15 Hood # 1 13' 6.00' Long x 54' Wide x 24' High Riser # 1 Size: 0' x 0' NOTES - FIELD PIPE DROPS AS SHOWN SLEEVING, ELBOWS, TEES, AND NOZZLES SUPPLIED BY CAS - RELOCATE NOZZLES IF FLOW PATTERN IS BLOCKED BY SHELVING, SALAMANDERS, ETC. - MAXIMUM 9 ELBOWS IN SUPPLY LINE. - MINIMUM 72 INCHES OF AGENT LINE FROM TANK TO FIRST NOZZLE. - IF APPLICABLE, PRE -PIPED CHARBROILER DROPS ARE SHIPPED LOOSE. - FACTORY PIPING EXTENDS A MAXIMUM OF 6' ABOVE THE TOP OF THE HOOD. APPLIANCE DIMENSIONS LISTED REPRESENT THE COOKING SURFACE SIZE, NOT THE OVERALL APPLIANCE SIZE. THIS FIRE SYSTEM COMPLIES WITH U.L. 300 REQUIREMENTS Job #: 3595328 Job Name: Trapper Sushi - Federal Way R1 Drawn Byye System SIzeN ANSUL-3.0/3.0-MANIFOLD Total FP required: 15 Hood # 1 13' 6.00' Long x 54' Wide x 24' High Riser # 1 Size: 18' Dia, Hood # 1 Metal Btow-Off Caps included. LEGEND - FIRE CABINET ANSUL SYSTEM lA 1.5 GALLON TANK iB 3 GALLON TANK 2 OEM AUTOMAN RELEASE 3 OEM REGULATED RELEASE 4 OEM REGULATED ACTUATOR 5 ANSULEX LIQUID AGENT (3 GAL.) 6 ANSULEX LIQUID AGENT (1.5 GAL.) 7 CARTRIDGE (101-20) 8 CARTRIDGE (101-10) 9 CARTRIDGE (101-30) 9A CARTRIDGE (LT-A-101-30) 9B DOUBLE TANK CARTRIDGE 10 TEST LINK 11 DOUBLE MICROSWITCH 12 HOSE ASSEMBLY 1100 DUCT NOZZLE (430913) 2W DUCT NOZZLE (419337) IW NOZZLE ASSEMBLY (419336) 1F NOZZLE ASSEMBLY (419333) IN NOZZLE ASSEMBLY (419335) 1/2N NOZZLE ASSEMBLY (419334) 3N NOZZLE ASSEMBLY (419338) 245 NOZZLE ASSEMBLY (419340) 230 NOZZLE ASSEMBLY (419339) 2120 NOZZLE ASSEMBLY (419343) 290 NOZZLE ASSEMBLY (419342) 260 NOZZLE ASSEMBLY (419341) 28 DETECTOR BRACKET 29 LOW TEMP FUSIBLE LINK 30 HIGH TEMP FUSIBLE LINK MGV MECHANICAL GAS VALVE EGV ELECTRICAL GAS VALVE 34 REMOTE MANUAL PULL STATION S SWIVEL ADAPTOR DUCT PROTl NOZZLE DETECTOR 1 REMOTE MANUAL PULL STATION REMOVABLE STAINLESS -/ STEEL SERVICE DOOR AGENT TANK OEM RELEASE/ BRACKET ASSEMBLY PLENUM PROTECTION INCLU➢ES FIELD INSTALLATION AND HOOKUP DURING NORMAL BUSINESS HOURS NOZZLE BY CERTIFIED INSTALLERS ONLY IN THE LOCATION NOTED ABOVE, TWO SITE VISITS ONLY (ONE VISIT TO SET PULL STATION 8 SYSTEM HOOKUP AND ONE VISIT FUR ONE TESTI ADDITIONAL VISITS WILL RESULT IN ADDITIONAL CHARGES), ONE MECHANICAL GAS VALVE PER SYSTEM AT A MAXIMUM SIZE OF PERMIT, AND SYSTEM TEST. EXCLUDES UNION LABOR & PREVAILING WAGE (LABOR 8 WAGES WILL HE ADDED IF APPLICABLE), GAS VALVE INSTALLATION, ELECTRICAL HOOKUP AND CONNECTIONS, HANGING OF FIRE CABINET, SHUNT TRIP, HANDHELD EXTINGUISHER(S), ON -SITE RE -PIPING DUE TO EQUIPMENT LAYOUT CHANGES. NOTES - FIELD PIPE DROPS AS SHOWN APPLIANCE PROTECTION SLEEVING, ELBOWS, TEES, AND NOZZLES SUPPLIED BY CAS NOZZLE - RELOCATE NOZZLES IF FLOW PATTERN IS BLOCKED BY SHELVING, SALAMANDERS, ETC. - MAXIMUM 9 ELBOWS IN SUPPLY LINE. p - MINIMUM 72 INCHES OF AGENT LINE FROM TANK TO FIRST NOZZLE. - IF APPLICABLE, PRE -PIPED CHARBROILER DROPS ARE SHIPPED LOOSE. - FACTORY PIPING EXTENDS A MAXIMUM OF 6' ABOVE THE TOP OF THE HOOD. OPTIONAL PRE -WIRED ELECTRICAL TERMINAL BOX WITH TERMINAL STRIPS, - APPLIANCE DIMENSIONS LISTED REPRESENT THE COOKING SURFACE 3-PHASE CONTACTORS AND OVERLOADS SIZE, NOT THE OVERALL APPLIANCE SIZE. FAN AND LIGHT (IF APPLICABLE) CONTROL PANEL - THIS FIRE SYSTEM COMPLIES WITH U,L, 300 REQUIREMENTS TYPICAL ANSUL R-102 SYSTEM LAYOUT SPECIFICAT THE RESTAURANT FIRE SUPPRESSION SYSTEM SHALL BE THE PRE-ENGINEERED TYPE WITH A FIXED NOZZLE AGENT DISTRIBUTION NETWORK. IT SHALL BE LISTED WITH UNDERWRITERS LABORATORIES, INC. (UL) THE SYSTEM SHALL BE CAPABLE OF AUTOMATIC DETECTION AND ACTUATION WITH LOCAL OR REMOTE MANUAL ACTUATION. ACCESSORIES SHALL BE AVAILABLE FOR MECHANICAL OR ELECTRICAL GAS LINE SHUT-OFF APPLICATIONS. THE EXTINGUISHING AGENT SHALL BE A POTASSIUM CARBONATE, POTASSIUM ACETATE -BASED FORMULATION DESIGNED FOR FLAME KNOCKDOWN AND SECUREMENT OF GREASE RELATED FIRES. IT SHALL BE AVAILABLE IN PLASTIC CONTAINERS WITH INSTRUCTIONS FOR LIQUID AGENT HANDLING AND USAGE. THE REGULATED RELEASE MECHANISM SHALL BE COMPATIBLE WITH A FUSIBLE LINK DETECTION SYSTEM. THE FUSIBLE LINK SHALL BE SELECTED AND INSTALLED ACCORDING TO THE OPERATING TEMPERATURE IN THE VENTILATING SYSTEM. THE FUSIBLE LINK SHALL BE SUPPORTED BY A DETECTOR BRACKET/ LINKAGE ASSEMBLY. FIRE SYSTEM NO. Tag TYPE SIZE FLOW POINTS INSTALLATION SYSTEM LOCATION ON HOOD 1 A—ut R102 3A/3.0 15 Fire Cabinet Left I Left FNOE....... SYSTEM TAG I TYPE SIZE SUPPLIED BY Mechanical Mechanical 2,000 2,000 ����1 CaptWeAlre Systems CaptWeAlre Systems FIRE SYSTEM TAG KEY NUMBER - PART DESCRIPTION OTY. BY QTY. BY NO, FACTORY DIST. 0 - 0 - 43-15733 AIR CYLINDER ASSEMBLY - Air Cylinder and Tubing for Mechanical Gas 1 0 Valves (Ansul Part #15733) 0 - 0 - DISC UNION Bursting ➢isc Union Assembly for Manifold System. 1 0 0 - 0 - METALCAP-CB BLEIWOFF CAP - Metal 8 0 0 - 0 - Tank Strap Tank Strap - used for ANSUL Tanks 2 0 0 - 0 - UCTANKBRACKET Tank Bracket for fire system tank Installation in utility cabinets 2 0 1 - 1 - AT - 3.0 TANK(#SB> - 3.0 Gallon SS Tank (for use with Automan Release, Actuator, or SS Enclosure (11110- )> Macota 11 01-429862 2 0 3 - 3 - ANS-OEM REGULATED RELEASE - Amu( Regulated Mechanical Release/Bracket Assembly, OEM, R-102, Cartridge Detection Included, Ansul Part # 79493 3 0 5 - 5 - LIG-3A AGENT - Ansulex Low PH Wet Chemical Agent, 3 Gallon (UU 79372 0 2 9 - 9 - DT-CART Double Tank Nitrogen Cartridge 0 1 10 - 10 - TLINK LINK - Test Link (1 test link) Ansul Part It 24916, Macota # 20-24916 0 1 11 - 11 - MICRO-SDA MICROSWITCH KIT- Includes 2 switches and Mounting Hardware. Single Dual Electric Switch, One Standard Switch, One Alarm Duty Switch Ansul Part # 437155, 1 0 Macota # 08-437155 12 - 12 - HOSE HOSE - Rubber Hose 1 0 13 - 13 - 419337 NOZZLE - 2W Nozzle, Duct (Replaces ANSUL Part# 419348, CAS Part# 419337) A0001267 1 0 1 15 - 15 - 419333 NOZZLE - IF Nozzle, Appliance (Reptaces ANSUL Part # 419344, CAS# 419333) 1 0 16 - 16 - 419335 NOZZLE - IN Nozzle, Plenum/Appliance (Replaces ANSUL Part# 419346, CAS Part# 419335) A0001265 3 0 19 - 19 - 419338 NOZZLE - 3N No—te, Appliance (Replaces ANSUL Part# 419349, CAS Part# 419338) A0001268 3 0 25 - 25 - 418569 NOZZLE ADAPTOR - SwWel Nozzle Adaptor (Replaces CAS Part # 418569) 2 0 A0001274 26 - 26 - OSA-3/8 QUIK SEAL - 3/8' (UL) 8 0 27 - 27 - OPSA-1/2 PULLEY SEAL - 1/2' Hood Seat (UU Ansul Part # 423253, Macota # 32-79768 1 0 28 - 28 - S-DET DETECTOR - Series (Scissor Linkage) Ansut Part # 435547/435548 (Old 4417369/434480), Macota # 05-417369 6 0 29 - 29 - ANS-360FL FUSIBLE LINK - 360deg F, R-102 and PIRANHA, Ansul Part It 439088 2 0 30 - 30 - ANS-500FL FUSIBLE LINK - 500deg F, R-102 and PIRANHA, Ansut Part # 439232 4 0 34 - 34 - RPS-A REMOTE PULL STATION - Red composite (without wire rope) 434618 (Did 1 0 Macola #06-4835) 35 - 35 - PE -LT PULLEY ELBOW - Low Temp. Pulley Elbow, Set Screw Type Ansut Part # 415670, Macola # 11-415671 e 0 36 - 36 - PE -HT PULLEY ELBOW - High Temp Pulley Elbow, Compression Type, Ansul Part # 423251, Macota # 10-45771 1 0 REV IEt�IED FOR CODE COtlN?r"LIANCE APPF:OVED APR 22 2019 CRY of Tukwila BUILDING DIVISION nECEIVED CITY OF I UI{WILA 0R 17 2019 PERMIT CENTER cs QJ C5 U S -f-) O 1 � S U � S S Li O —I Q �D W • • • I n l� Q 3 DATE: 1 /14/2019 DIG.#: 3679252 DRABY RTB - 85 SCALE: 1/2" = 1'-0" MASTER DRAWING W" W h'Y"PATI"AT DA!`TI,1P`P _ /`.AJI99'709979 REVISIONS NO. TAG PACKAGE # LOCATION SWITCHES OPTION FANS CONTROLLED LOCATION QUANTITY TYPE 1 A H.P. 1VOLT1 FLA 1 DCV-1111 Utility Cabinet Left 0 - Utility Cabinet t 1 Light 1 Fan Smart Controls DCV Exhaust 3 2.000 208 611 Hood # 1 Suppty 1 3 2.000 208 1 6.1 Field Con--- m Router or Ettrernet Swat UR F-[ , VFed Connecibn to —1.— Kit Ll CASlink Monitor and Control Hood control panel to support communications to cloud -based BuRding ana Mgement System. - Hood Control Panel to allow cloud -based Building Management System to monitor real time parameters outlined as MONITOR In the points list. Hood Control Panel to allow cloud -based Building Management System to control parameters outlined s CONTROL In the points list. Hood control panel to allow remote changes to system setting such as, VFD Frequencies, ECM speeds, temperature set points, fan and wash schedules, etc. MONITORING AND CONTROL POINTS LIST 11CV PnckaQDs Function Room Tenpernture MgKDTDR Duct Teryferab I. MIMTOR WA Osc W Temperature MNUTIR Kitchen RN Usch roe Temperature NEMTDR Fan Speed N®NTIR Fnn Amperage MWIIR I— Power MNTITR VFD Faults 141Ni'TUR Controller Faults MUNITUR Fnn Faults MBIli1R Fnn St.— NffiITOR MU F..ts HCNMIR PCU FAter CIO, Percentages MGMTUR FMe Con,lttlon NBQLUR CORE Fire System HUN IDR BWldln, Pressures NUNI TDR Prep Tine Hutton MOoiOR t. ce"e Fvis Hutton iGAIITOR E CONTRm lSgMs Button MGMTOt 6 CONTRO_ Vnsh Button lGNIIIOR R [INTRO - SC Pockegas Functbn Room TenperaMre(s) MWTBR Duct Tenp¢rndmeCs> NOOTOR NUA Osdmrge Tenperat,,. NDNODR Mn RTU DlscMorge Temperature IGNITOR Controller Faults HMMIR Fnn Faults MINITGR Fnn Status MNITOR PCII Fauts HIRUTDR PCU Hater Clog Percentages NDNTDR FFe Condition MUNROR CURE FFe System HEINSTOR BWlding Pressures HmNmgR Fors Buttonts) MINITOR L MNIRO. Llghts ButtoM) NRWITIR L MNTRO- Nosh Button MONITOR , —. JOB NO MODEL NUMBER mssuDc I+Tf DESCRIPTION OF OPERATION: 3679252 ncv-uu ETA Lw� �` JOB NAME T Sum - Sww msat � tappet` nA I t/t4/2W9 Dw ECP el-3 �s � �a tome fx swa nsmuem vervfy usm.,Q nee.em v�w�mri cmvao�ml met m�ua eoR�iy 1 z BREAKER PANEL TO PRIMARY CONTROL PANEL CONTROL PANEL TO ACCESSORY ITEMS cmMTRo-P ----�" - Responskilityt Electriclon Respansi�etyt Electrid— _ DRY CONTACT ___-- t9RNALLY UPEN - 5 BREAKER SIZE SHOWN IS THE MAXIMUM ALLOWED gmam PANEL oN/�F WITH ------_- MINuN — IM BREAKER PANEL PRIMARY CW-IRm PANEL SUPPLY FAN NWmALLY �PRN _— '� 1 4 LFOSVtiCN 1 �M@M I�,LY UmEN _- —FAN IS To 5 I5 A CONTROL POWER. DO NOT WIRE ME SYSTEM ---. --- DCV SPEED +- - - - - - - - - - - - TI Ems TO GFCI OR SHUNT TRIP BREAKER. MCI T� 1 � AAIN M N3MLLy CUISED 4a. C3 TO AW SFOIA.D FNVE MS-t 44Ip a__- ----------- /N PCBQ A�SPNTER-S s SIRRID V/ `TER CWTIElITT YN]M PktEA (TOTW SEE ECPNKi IiVIERS MYAMY. C@1LRd nDl inn t ----____---- BREAKER 3PR DNE--- FI SYST�EMN WIRE i— HS-2p4PDi VF➢AN&M----------- _ D-1DV WSP _ - T➢ BMS T _ _ _ _ _ _ _ _ _ _ _ _ LDE 208 V------------`LDS IN SERIES qS SHOWN L t C W VFO WAI Is THY.'— MCN 7b A ILe2 ®.----------- ---� (EACH VFD) SEE VFD UWlERS MAM)AL. B Nmrn, 15 A EXH-1 SM-1 BMs svncH WIRE TD VFD QUICK CONNECTOR C@ffRR. PANEL ALL SWITCHES FACTORY VRED CONTRfl P - _—_------__ C—p/ TO _------____ — g — — — — — — — — — — — — ADS III J4 CAT-5 CONECTIN IXTERNAL SI@MN. SWITCH TIRIUGH ]INSBREAKER - � 3PN—___--------- as V SV TCFES SNITCH LIILLACTIVATE MCI FANS AND WL to ------------_INS. MCN 74 A _ MOCR 15 A SUP-2 _ _ SM-2 WIRE TO VFD QUICK CONNECTOR TOEWM ---------VWTE it H{G®LIGHTS®----- -- GREEN -___, 14W V MAX WIRE TO J B]x 0 TtP W M® 1z - cueH RW(ER CONTROL PANEL TO FANS cIXiRT Palm. uT-s EI1ENEr mEECIm+ ty ResponslH(ttlm Electrcian ----------- -� PRIHVRY PANEL— FANS W MIRE DIRECILY TO CUpUMCATIN NOME. SETT RQMRES U DHW V ULP PORT 1.4 6 1445 WEN 1TR 14 Loatl Virtg —LT° _ FAN 01 — 1 OTBOJNO TRAFFIC Q1Y. CDI4IRLLP ._i-yam, SM-1-4aeoJfSd— __ — n �H9Y ----------- 1s WIRE TO — �ffi._._ --_— VFD MEN _— _— ---- — —� TO FTI vDEE Ili CW1WL H64R➢. MSTPLi. =—=J PoDN TE1P CWNECT3R WRE TO � TEMP ST96Ot IN MEN AWAY FROM HEAT Is MUST HAVE ITS OVtI CONDUIT DO MITI SHARE COAU11M DISCONNECT SENSUR SORCES. III NOT INSTN SENSOR 01 THE CEI-Nil GRIM SEE FAN, 02 SIMo2 CINIRO. P /7 —.IDV.J46_t_ Load VNAg — FACTORY VIP I Et CAPTURE SENSOE HmRtm W F® CAUR I CPPTIRE 1 SM-2 — ig+u_tga— '� V CAPTURE VOLUME WIRE To — �— 1H VFD QUICK o CONNECTOR -��'- --sue.— THE MUDWIG CONNECTIONS 19 IF VFD HU NTE➢ IN END PANEL, MUST HAVE ITS -N CONDUIT MY ER MAY NIT BE REGENED��DO4T JORSRE WIRE Sr SIGNAL DI NOT SHARE CONDUTI FROM PANEL WILN mD. ----ANT TQS T U1S- N ECPM03. MNRIL P w.Tov[.tAPTR TAKE LP AIR PCH MlM ZONE 1 SIGNAL FOR _ NEINTRAL FROM SHORT DID ---� 21 DATER ------- PROVING --------- � -® EXTERNAL SHOT TRIP ST TERMINAL IS E WETY IN FIRE COIDTIM.. INTERLOCK Led VOLTAGE CIDBNECTIIW FOR DANDER IN7OMo . WIRE MULTIPLE SUPPLY W THE SAME E°iw r' MNE IN SERIES. SNQULD COHFO- P — — — — — N�MALLY WEN HAVE CONTINUITY WIEN DAMPER IS DRIVEN OPEN. SPARE FIRE SYSTEM DRY SPARE �MTACTS WILL NAIAD C2 lI PR2 WHEN SYSTEM IS ARME& THEY _ 2T NaT REQUOED FOR ALL LDIITS SEE MAKE -AM AIR SCHEMATIC. CONTACT hTD AM STO DISRW.E EQUIPlmMT IR M"Im SITNALS. OBIT FOR SUIL➢M FIRE ALARM VMCH MIST NE WIRED DIRECTLY TI THE ANSLL 24 M➢t I`MA SWITCH L➢CATED Demand Control Ventilation Hood Control Panel Soecificationsi Controls shall be listed by ETL (UL 508A) and shall comply with demand ventilation system turndown requirements outlined in IECC 403.2.8 (2015). The control enclosure shall be NEMA 1 rated and listed for installation inside of the exhaust hood utility cabinet. The control enclosure may be constructed of stainless steel or painted steel. - Temperature probe(s) located in the exhaust duct riser(s) shall be constructed of stainless steel. ---- A --- i B C DI E I F I G - H I UNLESS SPECTED OTHERWISE, ALL FACTORY AC WIRING 16 AWG. ALL FACTORY DC WIRING 18 AWG. MOTOR POWER CIRCUIT FACT13RY WIRING SCHEMATIC I am NITER IF VFD HAS wH 240V INPUT, IASE u b L2 DNLY. CIRCUIT BOARDS J9 120V i s ° --- CONTROL INPUT FARL ® -`K ®_. _ _ 120V HS=LINE, IF VFD HAS )PH MV INPUT, USE Li 4 N ULY. MTR'EKH-t 14 qvG o F�2�.a� as V - PION A ECPM03 DOW Rev. 210. MMI Rev. 210.E `/qC __Nc _ _ N1=NEUTRAL, 15A —®- BREAKER. DO 24V 8 9 CUM -I ----- Is gV/i3 P3oz,°.o of 12u RELAY 24 RELAY NOT CONNECT 4 1 3 4 5 6 7 o..,..A - TO SHUNT TRIP - * CV J 2 =vwpd m DCtp roster faiE of npppcnde> OlpIIml PS®� u P131,N/ No a s Nc 2 1 WE 8 T NO 4 3 Nc 2 1 IL D 7 _ BREAKER. SEE PS-0I m llC _ P134N/A N msa.PI coM s s coN s s PM ® INSTALLATION C SCHEMATIC FOR A - — - ADDITIONAL RED. c> a ® — a o,.,.,, PANEL LIDIj-GR..-- f,}--- ��s OCAT-5 1 o .0 VFpEm�1o2YXg5n1`19a225 P410d MTTaSuP-2 I'L 61q 14 AWG FLW61- 3 PH O Urtt Plobm� COMPONENT LIST R+'m 3 206 V V/T2 15 A VR3 M) �0 O-x Nveriooa mite• ml He xnt m uK L�iai<on`}o`oena eit PSOT�m of the. %aw PK6 ETL4^M h e ty RJ15 Pa MM.7 P133rN/A PS-1 Pmm SAP 2,VDC PNMPI BNA-�[ ECPN03/NSSY CRAW M M67- HK3MDmi� wD 60A VFD p19M225 �'P41P21 RD-. 24vpC t��ryry�� Relay iPM311IA01�➢ i I I M-z J7 126V 2 pK® BK 14AY1Gy�-j.�dHl IN S En IN F� ® —BKuA"�"cm R.c Pmx°v eits_w1pa2 `� � ntmaoi 6 ARI_W A-1 B VN N1 Aft. —FACIIih' W➢RE &- GAO( VV- TOIW 7 I.- alE GY- OSY 82- H.IINi FR- nPtE Ro- rSp DRY CONTACTS (SHOWN DE -ENERGIZED) "'I'''''n'E _ _re 14 AWG RA-1-1 oLD-- UVR sl st MANE W AR IHERLIXKWN — RNON- RDrtN SRO£ NVB_- lH/I. STRNPE EF::BK N� 14 AVG RA-r2v-1P F�j���_ WT wsTtPW , D.C�V ito HKEF EF M EcL - c 0� P�o-aOF re,itna 'm°fo'aerw�T @RY PAN - to AVG RA 2-2 c ��„m 9 ierioTaru DULY a gV.�t%�1ER z1pPfeeaR�ua�ir xW hthllatlenV�fm aaumm mut4 amty M detwce emceeae m 0 JCB NO IwAIN BT TYPE owe NOECP DAIS f1-2 SC-20 x 18 x 842 BO DUCT A digital controller shall be provided to activate the hood exhaust fans dynamically based on a fixed differential between the ambient and duct temperatures sensors. This function I shalt meet the requirements of IMC 507.1.1, I A digital controller shall provide adjustable hysteresis settings to prevent cycling of the 0 fans after the cooking appliances have been turned off and/or the heat in the exhaust system is reduced. CONTROL PANEL A digital controller shall provide an adjustable minimum fan run-time setting to prevent fan LCD cycling. INTERFACEROOM TEMPERATURE Variable Frequency Drives (VFDs) shall be provided for fans as required. The digital SENSOR controller shalt modulate the VFDs between a minimum setpoint and a maximum setpoint on demand, The duct temperature sensor input(s) to the digital controller shall be used to TYPICAL HOOD CONTROL PANEL INSTALLATION calculate the speed reference signal. The VFD speed range of operation shalt be from 0% to 100% for the system, with the actual minimum speed set as required to meet minimum ventilation requirements, Sequence of ❑perationsi The hood control panel is capable of operating in one or more of the following states at any An internal algorithm to the digital controller shall modulate supply fan VFD speed given timei proportional to all exhaust fans that are located in the same fan group as the supply fan, - Automatic, The system operates based on the differential between room temperature and the temperature at the hood cavity or exhaust duct collar, Fans activate at a The system shall operate in PREP MODE during light cooking load or COOL DOWN MODE when configurable temperature differential threshold, Depending on the job configuration each fan sufficient heat remains underneath the hood system after cooking operations have zone can be configured as static or dynamic. These terms refer to whether a variable completed, Operation during either of these periods wilt disable the supply fans and provide motor (such as EC Motors or VFD driven motors) modulate with temperature. If the panel is an exhaust fan speed that is equal to the minimum ventilation requirement. equipped with variable speed fans and the zone is defined as 'dynamic', these will modulate within a user -defined range based on the temperature differential. Panels equipped with A digital controller shall disable the supply fan(s), activate the exhaust fan(s), activate variable speed fans and a fan zone defined as 'static', fans will run at a set speed the appliance shunt trip, and disable an electric gas valve automatically when fire condition calculated for the drive. Demand control ventilation systems are capable of modulating is detected on a covered hood. exhaust and make up air fan speeds per the requirements outlined in IECC 403,2.8, A digital controller shall allow for external BMS fan control via Dry Contact (external - Manual: The system operates based on human input from an HMI, control shall not override fan operation logic as required by code). - Schedule: A weekly schedule can be set to run fans for a specified period throughout the An LCD interface shall be provided with the following features: day. There are three occupied times per day to allow for the user to set up a time that is a. On/Off push button fan & light switch activation suitable to their needs. Any time that is within the defined occupied time, the system will run b. Integrated gas valve reset for electronic gas valves (no reset relay required) at modulation mode and follow the fan procedure algorithm based on temperature during this c. VFD Fault display with audible & visual alarm notification time. During unoccupied time, the system will have an extra offset to prevent unintended d. Duct temperature sensor failure detection with audible & visual alarm notification activation of the system during a time where the system Is not being occupied. e, Mis-wired duct temperature sensor detection with audible & visual alarm notification f. A single low voltage Cat-5 RJ45 wiring connection - Other: The system operates based on the input from an external source (DDC, BMS or g. An energy savings indicator that utilizes measured kWh from the VFDs hard -wired interlock) REVIE�fIJLsi i=CR CODE C0121"1IANCE APPROVED APR 22 2919 City of'Tukwila BUILDING DIVISION MC,r"VED CITY OF i u,,'W1LA APR 17 2019 PERMIT CENTER c5 Q� S d U � CID Co 00 O +> Q� I Q s s 3 :5 4) 5 W O Q co Q `0 W DATE: 1/14/2019 DWG.#: 3679252 DRAWN RTB - 85 SCALE: 3/4" = 1'-0" MASTER DRAWING SKEET NO. 3 System Design Verification (SDV) REVISIONS If ordered, CAS Service will perform a System Design Verification (SDV) once all equipment has had a complete start up per the Operation and Installation Manual, Typically, the SDV will be performed after all inspections are complete. Any -Field related discrepancies that are discovered during the SDV will be brought to the attention of the general contractor and corresponding trades on site, These issues will be documented and forwarded to the appropriate sales office, If CAS Service has to resolve (a discrepancy that is a -Field issue, the general contractor will be notified and billed for the work. Should a return trip be required clue to any field related discrepancy that cannot be resolved during the SDV, there will be additional trip charges. During the SDV, CAS Service will address any discrepancy that is the fault of the manufacturer. Should a return trip be required, the general contractor and appropriate sales office will be notified. There will be no additional charges for manufacturer discrepancies, —RkEV11&PvED FOR t?LIANCE APPROVED 2019 Tukwila DIVISION CODE COMPLIANCE '6 APPROVED APR 22 2019 City of Tukwila BUILDING DIVISION nECEIVED CITY OF TUKWILA Q:f C5 F DATE: 1/14/2019 DWG.#: 3679252 DRAWN By.RTB - 85 SCALE: 3/4" = 1'-0" MASTER DRAWING APR 17 201,3 PERMIT CENTER WM