Loading...
HomeMy WebLinkAboutPermit M19-0093 - 902 BUILDING / VACANT SPACE - NEW UNIT HEATERVACANT SPACE 902 INDUSTRY DR M19-0093 " Parcel No: Address: Project Name: C) �=^�xx ^�� Tukwila ~°U~� x�u n ��m^���na Departmentmf Community Development Tukwila, Washington 9O1BB Phone: 206-431-3670 Inspection Request Line: 206-438'9350 Web site: http://www.TukwilaWA.gov 2523049015 808 INDUSTRY DR VACANTSPACE " MECHANICAL PERMIT- ° 1� Permit Number: K813'0093 Issue Date: 6/27/2019 Permit Expires On: 12/24/2019 Owner: Contact Person: Name: Address: corunv,to,: Name: Address: License No: Lender: Address: 17UlQUAIL STSTE1OO,NEVVPOKT BEACH, WA, 92660 PRO STAFF MECHANICAL INC POBOX 33]7U'5EATTLE WA, 98133 PRO5TN1|072NG ''' Expiration Date: 7/2/2020 DESCRIPTION OF WORK: lNEW UNIT HEATER Valuation of Work: $6,350.00 Type ofWork: NEW Fuel type: GAS Fees Collected: $29078 Electrical Service Provided by: PUGETSOUND ENERGY VVaterDi5trict: TUKVV|LA Sewer District. TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: ized Signature: National Electrical Code: VVACities Electrical Code: VVAC29646U: YvAState Energy Code: 2017 2017 2017 2015 Date: —7— 1.4 Q `~~~~ � � |hearbycertify that Ihave read and examined this permit and know the same tobetrue and correct. All provisions oflaw and ordinances governing this work will becomplied with, whether specified herein nrnot. The granting oft" �^ mitdoes not presume tngive authority tnviolate orcancel the provisions ofany other state orlocal |^mare8u|, inXconstructio" ^ ~ per onnanceofwork. |amauthorized tosign and obtain this development ioermit and , gree to e conditions attached to this permit, Bgnat110IN���@lANkh,&_ Date: Print Name: This permit shall become null and void if the work isnot commenn��ithinl8Odays for the date ofissuance, nrif the work is suspended urabandoned for aperiod ofI80days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval, Z: Al construction shall bedone in conformance with the Washington State Building Code and the Washington State Energy Code, 3: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will hedetermined bythe building inspector based nnsatisfactory completion ofthis requirement, 4: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City nfTukwila Building Department (2O64]l,]67O). 5: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 6: VALIDITY OFPERMIT: The issuance urgranting ofapermit shall not boconstrued tobeapermit for, oran approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances ofthe City nfTukwila shall not bevalid. The issuance nfapermit based onconstruction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 7: `MECHANICAL PERMIT CONDITIONS"* 8: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (2O6/43l']670). 9: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted, 10: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206)438-9350 0703 MECHEQUIP EFF 1800 MECHANICAL FINAL 0701 ROUGH'|NK4ECHAN|[Ai Parcel No: Project Name: �~^�«x ^�� Tukwila v~U~� ��o x ��o�m��oa Department of Community Development 6]OOSouthcenterBoulevard, Suite #10O Tukwila, Washington 98188 Phone:2O6'431'3G7U Inspection Request Line: 206-438'935O Web site: http://www.TukwilaWA.gov 2523049015 902 INDUSTRY DR VACANT SPACE MECHANICAL PERMIT Permit Number: K419'0093 Issue Date: 6/27/2019 Permit Expires On: 12/24/2019 Owner: Address Contact Person: Name: Contractor: Name: Address: License No: Lender: Name: Address: 1701 QUAIL STSTEl0O,NEVVPORT BEACH, WA, 92660 KEV|NMURPHY PRO STAFF MECHANICAL INC POBOX 3337O'SEATTLEWA, 98l33 PROST[w|072NG ''' Phone; (200)361f0071 Expiration Date: 7/2/2020 DESCRIPTION OF WORK: 1NEW UNIT HEATER Valuation of Work: $6,350.00 Type ofWork: NEW Fuel type: GAS Fees Collected: $29078 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKVV|LA Sewer District: TUKWILA Current Codes adopted bythe City ofTukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: ized Signatu National Electrical Code: VvACities Electrical Code: YVA[29646B: WA State Energy Code: 2017 20172017 2015 -1 � Date: � �/-^--��1 v / � �- | hearbyuerdfy that | have mad and examined this permit and know the same to betrue and correct. All provisions of law and ordinances governing this work will be compiled with, whether specified herein or not. The granting ofthis permit does not presume togive authority toviolate orcancel the provisions nfany other state nrlocal laws regulating construction urthe performance ofwork. |amauthorized tosign and obtain this development perm8UMdagree tothe conditions attached tothis permit. Signature: PhntNam�: Date: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended orabandoned for aperiod ofI8Odays from the last inspection. PERMIT CONDITIONS: l: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All construction shall bedone inconformance with the Washington State Building Code and the Washington State Energy Code. 3: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will bedetermined by the building inspector based nnsatisfactory completion ofthis requirement. 4: All plumbing and gas piping work shall be 'inspected and approved under a separate permit issued by the City ofTukwila Building Department (ZO6431,367O). 5: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. G VALIDITY OFPERMIT: The issuance urgranting ofapermit shall not beconstrued tobeppermit for, cvan approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances ofthe City ofTukwila shall not bevalid. The issuance ofapermit based onconstruction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 7: *** MECHANICAL PERMIT CONDITIONS' 8: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (Z06/43l,367O). 9: All permits, inspection record card and approved construction documents shall be kept at the site nfwork and shall be open to inslpection by the Building Inspector until final inspection approval is granted. 10: Manufacturers installation instructions shall beavailable onthe job site atthe time ufinspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (2Vs)4aO'93s0 0703 K8E[HEQUIP EFF 1800 MECHANICAL FINAL 0701 ROUGH'|NyN[[M4N|CAL CITY OF TUKW0'11s,,,. Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 httn://www.TukwilaWA.gov Mechanical Permit No. Project No. Date Application Accepted: 10 i>*". t Date Application Expires: 1?--- (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** King Co Assessor's Tax No.:Site Address: qV7•••- .121.911rtr -1V-- • 5r-Orl 7.E ?VS' Suite Number: et;te" Floor: Tenant Name: New Tenant: )X. Yes El ..No PROPERTY OWNER Name: BIALA. gpozvoci- . Address: pp -apC... tOri &43 0 Cityr..avii.,E State: OA . Zipelis i CONTACT PERSON - person receiving all project communication Name: loleay_› p. Address: pp B.,„.. g 337P City: e....its-t LE- State: vi it.. ZiWo33 Fax: Phone:?.coltoi iv? I 74267164 0442.4 Email: .0-4. gjilf), snare:40w 144., MECHANICALCONTRACTOR INFORMATION Company Name: Address: pp -130F — %IP 12' City: 5e4cri...6- State: Zip. ( , , , Phone: Fax: 3 Contr Reg No.: :470.5711,4V72-7 Date:7/2.1w) Tukwila Business License No.: B- Z7 5 ,GotAA Valuation of project (contractor's bid price): Describe the scope of work in detail: b15 tiT tewnaq--- Use: Residential: New Replacement LJ Commercial: New Replacement ........ Fuel Type: Electric El Gas Other: ApplicationsTorms-Applications On Line2016 ApplicationsMechanical Permit Application Revised 1-4-16.docx Revised: January 2016 hh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace > l 00k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent I Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfin Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat 1 Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-10PM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (lam-1 Opm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justiciable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CE • TLEY THAT I HAVE READ AND ED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY 0 ' ERJURY BxTHE LAWS OF - STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUIL Sign Print Name: Mailing Address: TH P ' ZED AGENT: Date: Day Telephone:Lam/ t / (`%�7 ' wA.' /33 ? !q State Zip H:iApplicationsiForms-Applications On Line12016 Applications\Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 Page 2 of 2 Receipt Number DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK $494.30 EL19-0468 Address: 902 INDUSTRY DR Apn: 2523049015 $69.62 ELECTRICAL $66.30 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0,00 $66.30 TECHNOLOGY FEE $3.32 TECHNOLOGY FEE R000.322.900.04.00 0.00 $3.32 M19-0093 Address: 902 INDUSTRY DR Apn: 2523049015 $290.78 MECHANICAL $279.60 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322,100,00.00 0.00 $190.53 PLAN CHECK FEE R000.322.102.00.00 0.00 $55.92 TECHNOLOGY FEE $11.18 TECHNOLOGY FEE R000.322.900.04.00 0.00 $11.18 PG19-0079 Address: 902 INDUSTRY DR Apn: 2523049015 $133.90 GAS $128.75 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $35,00 PERMIT FEE R000.322.100.00.00 0.00 $68.00 PLAN CHECK FEE R000.322.103.00.00 0.00 $25.75 TECHNOLOGY FEE $5.15 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R17787 R000.322.900.04.00 0,00 $5.15 $494.30 Date Paid: Monday, June 03, 2019 Paid By: PRO -STAFF MECHANICAL INC Pay Method: CHECK 17182 Printed: Monday, June 03, 2019 1:44 PM 1 of 1 SYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 Permit Inspection Request Line (206) 438-9350 Project: Type of nspec on: Addres : Date Called: Special Instructions: LDate Wanted: a.m. p.m. 'Requester: Phone No: _ 3 esfa id1/444, LV-2,71 -II pproved per applicable codes. Corrections required prior to approval. C, ENTS: nsp cto : Date: REINSPECTION FE RED. Prior to next inspection. fee must be paid at 6300 Southcenter lvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 1Z1� 0073 Project: 041 'Type of In p on: Address: f I!" Date Called: Special Instructions:r ,Date Wanted: 7. a.m. p.m. Requester: Phone Nip: Approved per applicable codes. © Corrections required prior to approval. nspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100, Call to schedule reinspection. (4- INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431670 Permit Inspection Request Line (206) 438-9350 Project: Type of I colon: Address: fl Date Called: Special Instructions: Date Wanted: a.m. p.m. Requester: Phone No: proved per applicable codes. Corrections required prior to approval. CO M [ ENT nspecto Date: REINSPECTION FEE REGtUIRED, Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Gall to schedule reinspection. REZNOR Model UDAP DESCRIPTION STANDARD FEATURES REVIEWED FOR CODE COMPLIANCE APPROVED JUN 2 5 2019 City of Tukwila BUILDING DIVISION OPTIONAL FEATURES - FACTORY INSTALLED Page Number Power Vented, Low Static Axial Fan Unit Heaters for Residential and Commercial/Industrial Use Sizes 30-125 approved for utility applications such as residential garages under CSA International Requirement 10.96 - U.S. and CR96-0005 - Canada CSA 26b ANSI Z83.8b Reznor ° V3 Series Model UDAP gas -fired unit heaters are available in 14 sizes ranging from 30,000 to 400,000 BTUH gas input. Sizes 30-125 are approved for residential application. All sizes are approved for commercial/ industrial installations. Model UDAP heaters are designed for 82-83% thermal efficiency and are approved for installation in the United States and Canada by the Canadian Standards Association (CSA). Reznor V3 Series unit heaters have a refreshing new appearance with a glossy white cabinet finish and less visible hardware, Each size cabinet is easily suspended from either 2 or 4 suspension points. Or, an optional hanger kit for Sizes 30-125 allows for ceiling mounting. The low voltage terminal strip on the outside of the cabinet makes connecting control wiring easy with no panels to remove. The addition of a "G" terminal to the strip, along with the new design of the circuit board, allows for fan only operation (without adding relays). All units have a factory installed gas line nipple to the exterior of the cabinet for easy gas service connection. The preeminent new internal feature is the TcoRE2 ® heat exchanger and single burner combustion system. Other standard features include a single -stage gas valve, multi -try direct spark ignition with 100% lockout, pres- sure switch to verify vent flow, resiliently isolated venter motor, venter wheel with improved housing, resiliently isolated axial fan and motor assembly, and a high temperature limit control. Sizes 30-125 also include a flame rollout safety switch, Operation is controlled through an integrated circuit board. The circuit board monitors heater operation and has LED diagnostic indicator fights to identify abnormalities in control functions. The V3 Series unit heaters are designed to provide all the features you expect in a Reznor heater plus im- proved efficiency, easier installation, and a new look both inside and out. Look for the unique white unit with no visible front and bottom hardware, deep red louvers, black side handle, and angled corner to know you have a genuine Reznor unit by Thomas & Betts. • Sizes 30-125 certified for residential heating application • Sizes 30-400 certified for commercial/industrial heating application • 82-83% Thermal efficient — TOP in its class! • 50-60°F Rise range • TcoREz® titanium stabilized aluminized steel heat exchanger • Patented** TCORC 6 single burner combustion system including a one-piece burner assembly • 115/1/60 Supply voltage • 115 Volt open fan motor with internal overload protection • Transformer for 24-volt controls • Integrated circuit board with diagnostic indicator lights • Multi -try direct spark ignition with 100% lockout Fan relay (included on the circuit board) • Single -stage natural gas valve (field adjustable for operation to 9,000 ft. elevation) • Vibration/noise isolated fan and venter motors — designed for low noise operation • 2-pt and 4-pt Suspension — standard on all sizes External terminal strip for 24-volt wiring • External gas connection • .Full fan guard — engineered for safety • Improved cabinet design with less visible hardware and a NEW Reznor appearance • Single -stage, propane gas valve (field adjustable for operation to 9,000 ft. elevation) • Two -stage natural gas or propane gas valve - Sizes 60-400 • 409 or 316 Stainless steel heat exchangers • 208 or 230 Single phase voltage • Totally enclosed fan motor (Sizes 30-250, 115V only) • Common venting with other gravity vented Category 1 appliance(s) (Sizes 30-100) RECEIVED CITY OF TUKWILA JUN 03 2019 PERMIT CENTER Form RZ-C-UH (Version H) Page 8 U.S. Patent No. 6,889.686 19 00q3 OPTIONAL FEATURES - FIELD INSTALLED TECHNICAL DATA Model UDAP • Vent cap • Thermostat • Thermostat guard with locking cover • Vertical louvers - new design • Downturn nozzle kits - new design • Gas conversion kits (natural and propane) • Master/Slave controls for zoning up to six units • Ceiling suspension kit - Sizes 30-125 • Hanger kits for 1" pipe • Stepdown transformer (for 230/3 and 460/3 supply voltage) • Manual shutoff valves Page Number of Size 30 45 60 75 100 125 150 175 200 225 250 300 350 400 Input Heating Capacity BTUH 30.000 45,000 60.000 75,000 105.000 120,000 150,000 175.000 200.000 225,0007 250,000 300,000 350,000 400.000 kW/h 8.8 13.2 17.6 22.0 30.8 35.2 43.9 51.2 58.6 65.9 73.2 87.8 102.5 117.1 Thermal Efficiency (%) 82 83 83 83 83 83 83 83 83 83 83 83 83 83 Output Heating Capacity4 BTUH 24,600 37,350 49.800 62,250 87.150 99,600 124.500 145,250 166,000 186,750 207,500 249.000 290.500 332.000 kW/h 7.2 11.0 14.6 18.3 25.6 29.2 36.4 42.5 48.6 54,7 60,8 72.9 65.1 97.2 Gas Connection (inches) ° Natural 1/2 1/2 1/2 1/2 1/2 1/2 .-. 1/2 1/2 1/2 3/4 3/4 3/4 3/4 3/4 Propane 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 3/4 3/4 3/4 3/4 3/4 Vent Connection Size (inches diameter) 4 4 4 4 4 4 5 5 5 5 5 6 8 6 Control Amps (24 volt) 1,0 1,0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1,0 1.0 Full Load Amps (115 volt) 1,9 2.4 2.4 3.3 3.9 5.1 3.8 3.8 4.6 7.5 7.5 11.0 11.0 11.0 Maximum Over Current Protection (115V) ° 15 15 15 15 15 15 15 15 15 15 15 20 20 20 Normal Power Consumption (watts) 109 155 155 217 276 354 392 392 491 747 747 1086 1086 1086 Discharge Air Temperature Rise (F) 50 55 60 60 60 60 60 60 60 60 60 60 60 60 Air Volume CFM 456 629 769 961 1345 1537 1921 2242 2562 2882 3202 3843 4483 5123 M2/minute 12.9 17.8 21,8 27.5 36.7 45.9 54.4 63.5 72.5 81.6 90.7 108.8 126,9 145.1 Discharge Air Opening Area ft2 0.96 0.96 1.25 1.25 2,01 2,01 2.56 2.56 2,56 3.51 3.51 4.79 4.79 4,79 M2 0.09 0.09 0.12 0.12 0.19 0.19 0.24 0.24 0.24 0.33 0.33 0.45 0.45 0.45 Output Velocity FPM 475 656 616 770 668 763 752 877 1003 820 911 802 936 1069 M/minute 145 200 188 238 196 245 229 267 306 250 278 244 285 326 Fan Motor HP E Open 0.02 0.03 0.03 0.06 1/30 1/20 1/6 1/6 1/6 1/4 1/4 1/2 1/2 1/2 Enclosed 0.06 0.06 0.06 0.06 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/2 1/2 1/2 Fan Motor RPM 1550 1550 1550 1550 1050 1050 1050 1050 1050 1050 1050 1050 1050 1050 Fan Diameter (inches) 10 10 12 12 16 16 18 18 18 20 20 24 24 24 Sound Level dBA@40 15 ft 40 40 49 54 55 51 52 53 56 56 59 61 62 Approximate Net 'Weight lbs 54 59 67 72 96 101 172 187 187 203 215 269 294 306 kg 24 27 30 33 44 46 78 85 85 92 98 122 133 139 Approximate Ship Weight lbs 61 66 74 79 118 123 204 219 219 245 257 321 346 358 kg 27 30 33 36 54 56 93 100 100 111 117 146 157 163 " GSA rating for altitudes to 2000 ft, Size shown is for gas connection to a single stage gas valve, not supply line size. c Smaller or larger vent pipe diameters may be allowed: refer to the Venting Installation Manual, Forrn If vent diameter is different from vent connection, reducerfenlargers will be field -required. ° MODP = 2,25 x (largest motor FLA) + smallest motor FLA. Answer is rounded to the nearest commercially available circuit breaker. °All other information in this table is based on a heater equipped with a standard 115 volt open fan motor. Form RZ-C-UH (Version H) Page 9 Page Number of DIMENSIONS Model UDAP ±1 /16" (2mm) Size A B C D E F G H J K M N P Q R 30, 45 12 1/8 25 5/8 10 13 13/16 26 21 9/16 5 3/16 6 1/2 2 11/16 3 7/8 17 3/8 11/16 4 5/16 13 9 9/16 60 15 1/8 25 5/8 13 13 13/16 27 21 9/16 7 7/8 6 1/2 5 1/2 3 7/8 17 3/8 11/16 4 5/16 13 10 1/2 75 15 1/8 25 5/8 13 13 13116 27 5/8 21 9/16 7 7/8 6 1/2 5 1/2 3 7/8 17 3/8 11/16 4 5/16 13 10 1/2 100 23 1/6 25 5/8 21 13 13/16 28 5/8 21 9/16 14 1/2 6 1/2 8 3/4 3 7/8 17 3/8 11/16 4 5/16 13 10 1/2 125 23 1/8 25 5/8 21 13 13/16 29 3/8 21 9/16 14 1/2 6 1/2 8 3/4 3 7/8 17 3/8 11/16 4 5/16 13 10 1/2 150, 175, 200 20 1/8 38 3/16 16 2 3 42 35 3/8 8 1/2 8 1/4 5 7/16 6 1/2 25 11/16 1 3/8 8 3/16 22 3/16 16 3/8 225, 250 26 1/8 38 3/16 22 23 42 35 3/8 13 1/16 8 13/16 9 6 1/2 25 11/16 1 3/8 8 3/16 22 3/16 15 5/8 300, 350, 400 34 1/8 4 1 30 23 42 35 3/8 17 1/16 9 11 13/16 7 5/16 27 11/16 1 3/8 8 3/16 22 3/16 16 3/16 Size A B C D E F G H J K M N P Q R 30,45 (308) (651) (254) (351) (660) (548) (132) (165) (68) (98) (441) (17) (110) (330) (330) (243) (267) (267) (267) 60 (384) (651) (330) (351) (686) (548) (200) (165) (140) (98) (441) (17) (110) 75 (384) (651) (330) (351) (702) (548) (200) (165) (140) (98) (441) (17) (110) (110) (330) (330) 100 (587) (651) (533) (351) (727) (548) (368) (165) (222) (98) (441) (17) 125 (587) (651) (533) (351) (746) (548) (368) (165) (222) (98) (441) (17) (110) (330) (267) 152'00 5, (511) (970) (406) (584) (1,067) (899) (216) (210) (138) (165) (652) (35) (208) (564) (416) 225, 250 (664) (970) (559) (584) (1,067) (899) (332) (224) (229) (165) (652) (35) (208) (564) (397) 3040050 (867) (1,041) (762) (584) (1,067) (899) (433) (229) (300) (186) (703) (35) (208) (564) (411) P and Q - Hanger Dimensions for 4-pt Suspension N -► R - Hanger Dimension for 2-pt Suspension i i TOP VIEW 3/8"-16 Female Thread - all suspension points B D T A C I 1 REZNOR `/i ./�.�`►:wow FRONT VIEW 11 ._ 110,% _-.*•/A1111in r� ♦ETe2 CLEARANCES FROM COMBUSTIBLES Thermostat Connection (30-125 Vertical; 150-400 Horizontal) Line Voltage Inlet (connects at circuit board) Vent Connection (see Technical Data for size) Combustion Air Inlet External Gas Connection RIGHT SIDE VIEW (Access Panel) Size To Flue Connector Access Panel Non -Access Side Bottom' Rear inches mm inches mm inches mm inches mm inches mm inches mm 30-125 1 25 6 152 18 457 1 25 1 25 18 457 150-400 4 102 6 152 18 457 2 51 1 25 18 457 Form RZ-C-UH (Version H) Page 10 'Suspend the heater so that the bottom is a minimum of 5' (1.5M) above the floor. PERMIT COO D COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M19-0093 DATE: 06/03/19 PROJECT NAME: VACANT SPACE SITE ADDRESS: 902 INDUSTRY DR X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: AT kM Building Division Public Works ire Prevention Structural PRELIMINARY REVIEW: Not Applicable (no approval/review required) REVIEWER'S INITIALS: Planning Division Permit Coordinator II DATE: 06/04/19 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required Denied (corrections entered in Reviews) (ie: Zoning Issues Approved with Conditions DUE DATE: 07/02/19 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping PW Ej Staff Initials: 12/18/2013 City of Tukwila REVISION SUBMITTAL Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://ww v.Tul:wilaWA.o1 Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 7/ t Jia, Plan Check/Permit Number: M 1 ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # - Revision # ( after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner ❑ Deferred Submittal # Project Name: Project Address: 90i, Ti Contact Person: Vu, Phone Number:.1 bi'© !ram %L / Y 2_77 Summary of Revision: S7 L> bk- RECEIVED CITY OF TUKWILA JI 'L 0 1 201Q PERMIT CENTER Sheet Number(s): "Cloud" or highlight all areas of revision includin ate of revisi Received at the City of Tukwila Permit Center by: ntered in TRAKiT on W:%Pernut CentetiTemplatessFormstRetision Submittal Form doe Revised: August 2015 111)(11C ESpanoi Contact. Search L&I Safety & Health Claims & Insurance k Washington State Department of / Labor & Industries A-Z Indcx uelp Myl,&J Workplace Rights Trades & Licensing PRO STAFF MECHANICAL INC Owner or tradesperson Principals ALMO, LEONARD LEE, PRESIDENT ALMO, PENNY H, VICE PRESIDENT Doing business as PRO STAFF MECHANICAL INC WA UBI No. 601 038 859 PO BOX 33370 SEATTLE, WA 98133 206-361-0071 KING County Business type Corporation Governing persons LEONARD ALMO PENNY H ALMO, OMWBE Certifications No active certifications exist for this business, Apprentice Training Agent Not allowed to have apprentices. icense Verify the contractors active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. PROSTMI072NG Effective — expiration 08/07/1993— 07/02/2020 Bond DEVELOPERS SURETY & INDEM CO Bond account no. 799707C $12,000 00 Received by L&I Effective date 01/26/2009 01/14/2009 Expiration date Until Canceled Insurance West American Ins Co $1,000,000.00 Policy no. BlW57849992 Help us improve Received by L&I 06/17/2019 Effective date 06/30/2017 Expiration date 06/30/2020 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No LSI tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Public Works Requirements Workplace safety and health VV,t, itttori hate Dept a'. attot l'I(1,ASISWS USO uftirfCS ssie ts suujocz to tile Imws of the state VVangton Help us improve Parking Lot SCOPE OF WORK: ■ New 30,000 BTU Power Vented Unit Heater with new Gas Piping From the New Meter location Adjacent Space f Parking Lot NEW REZNOR UNIT HEATER SCHEDULE TAG MAKE MODEL # SIZE CFM INPUT Output ELECTRICAL WEIGHT (BTUH) (BTUH) (LBS.) Y45 volts Full load UH —1 REZNOR UDAP-30 30,000 BTU 456 30,000 24,600 amps=1.9 MOCP=15 54 LBS EQUIPMENT NOTES: 1. Horizontal Duct Discharge. 2. Heating only thermostat/set for freeze protection only/45 Degrees 3. Unit to be suspended from the structure 4. Flue termination to be min. 10' - 0" from any fresh air intakes. 5. Gas Piping sized per Section 402.2(2) IFGC 3/4" @ 125"= 92.000 BTUH's Parcel 252304-9015 Number Parcel Number: 252304-9015 Name BKM TUKWILA Site 800 INDUSTRY DR 98188 Address BEG AT E 1/4 COR OF SEC 26-23-04 TH N 88-0642 W 105.84 FT TH S 01.47-28 W 90.66 FT TH S 88-12- 32 E 233 FT TO TPOB TH FR TPOS S 88-12-32 E 291.50 FT TAP ON SWLY MGN OF JAMES CHRISTENSEN RD NO 1479 TH ALG SD SWLY MGN S 32-39-25 W 96.43 FT TH S 20-16-25 W 114.09 FT TH S 03-06.25 W 122.73 FT TH S 02-41-35 E 98.54 FT TH S 19-53-35 E 168.86 FT TH S 32-38-35 E 158.24 FT TH S 44-38-35 E 25.37 FT TH LEAVING SWLY MGN S 01-47-28 W 461 A2 FT TH N 88-12-32 W 264 FT Legal TH N 01-47-28 E 18 FT TAP OF NLY MGN OF MINKLER BLVD TH ALG SD MGN N 88-12-32 W 103 FT TAP ON C/L OF PRIVATE DRIVE TH ALG SD C/L N 01.47-28 E 430 FT TAP OF CURVE TH TANGENT TO PRECEDING COURSE All ARC OF CURVE TO LFT 77.78 FT RAO 250 FT & C/A 17-49-33 TAP OF REV CURVE TH FIR A TANGENT WH BEARS N 16-02-05 W ALG ARC OF CURVE TO RGT 77.78 FT RAD 250 FT & C/A 17.49-33 TAP OF TANGENCY TH TANGENT TO PRECEDING CURVE N 01.47-28 E 577.17 FT TO.TPOB SUBJ TO U P RR OPER ESMTS Year Built 1976 Building Net Square Footage 19520 Construction Class MASONRY Building Quality AVERAGE Lot Size 338897 Present Use Industrial Park Views No Waterfront ILDING 1 SEPARATE PERMIT REQUIRED FOR: Mechanical Electrical Plumbing Gas Piping City of Tukwila BUILDING DIVISION ]/16'�1'•0' I I I l I Q PSMI #1940 o ... ' c a+ G .'2 g i m � coo 2 O C r C H G uL rn 42 •�'L Q N C m y� Ql uJ > lr��C w o m O �q > N 41 � C� UICID N0. c"i -•� w. e co E t2 to co O U m � qcOi avp�+ c oCNI dr @trot C ri COy o0 0 r N ® co yy3 cO E M *' O X m O a. it w a fn r I. 00 '!_ V 0 m o00 00� .�' 0 �d 1V 0PW4ti r Pk N m WJ "Zf N O O REVISIONS REVISIONS LCORD FOR No chaliges shall be n,�tae to the scope. IANCE of work wltnout. pnor a, Droval of the 'APPROVED Tukwila Building Division. NOTE: Revisions will reaurre a new plan 19submittaland may inciiine aadltional plan review.ila .SION DRAW w DATE 5/31/19 RECEIVED CITY OF TUKWILA JUN 03 2019 CONTENTS