HomeMy WebLinkAboutPermit PG19-0113 - D'OYLEY RESIDENCE - REPLACE SIDE SEWERDOYLEY RESIDENCE
14480 58TH AVE S
CANCELLED
08/12/2019
PGI9-01 13
Parcel No:
Address:
Project Name:
C
��~�m� °�� Tukwila
~.U~� ��n v ��m^w��na
Department of Community Development
630OSouthcenuerBoulevard, Suite #1OO
Tukwila, Washington 9g1g8
Phnne:2O6-431'367O
Inspection Request Line: ZO6-QO-9B50
Web site: http://www.TukwilaWA.Rov
3]659Ol175
CyOYLEYRES|DENCE
PLUMBING/GAS PIPING PERMIT
Permit Number:
Issue Date:
Permit Expires On:
PGl9-0113
8/12/2OlU
2/8/2020
Owner:
Contact Person:
Name:
1448O58THAVS,TUKVV|U,WA,
98168
PAULD'OYLEY
1448O58THAVE 8,TUKVV|U\WA,
98168
Contractor:
Name: THE SEWER DOCTOR LL[
Address: 21265 254TMPL'DES MO|N2S,WA,
98198
License No: SEWERDL895CA
Lender:
^''
Phone: (206)234-3951
Expiration Date;
DESCRIPTION OF WORK:
REMOVE AND REPLACE SIDE SEWER FROM HOUSE EXIT TO STREET.
Valuation of Work: $5,000.00
Water District: TUKVv|LA
Sewer District: TUKVV|LA
Fees Collected: $138.43
Current Codes adopted by the City of Tukwila:
International Building Code Edition:
International Residential Code Edition:
International Mechanical Code Edition:
Uniform Plumbing Code Edition:
International Fuel Gas Code:
rized Signa
ational Electrical Code:
VVACities Electrical Code:
VVACZ9646B:
WA State Energy Code:
2017
2017
2017
2015
05 21
0505
?-ld'�x�
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local law gula 'ng construction or the performance of work. I am authorized to sign and obtain this
developme ermit d agree to conditions attached to this permit.
Date:
/�7
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS***
2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the
Tukwila Building Division.
3: All permits, inspection records and applicable plans shall be maintained at the job and available to the
plumbing inspector.
4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and
the Fuel Gas Code.
5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved.
6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and
Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of
the holder of the permit to make sure that the work will stand the test prescribed before giving notification
that the work is ready for inspection.
7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall
unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes
installed outside the conditioned space shall be insulated to minimum R-3.
8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing
shall be protected by steel nail plates not less than 18 gauge.
9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No
plumbing piping shall be directly embedded in concrete or masonry.
10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected
in accordance with the requirements of the building code.
11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin
layers to twelve inches above the top of the piping with clean earth, which shall not contain stones,
boulders, cinderfill, frozen earth, or construction debris.
12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or
an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other
ordinance of the jurisdiction.
13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit.
14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of
plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies
that use significant quantities of water shall comply with Washington States Water Efficiency ad
Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section
402 of Washington State Amendments
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
2000 GAS PIPING FINAL
8004 GROUNDWORK
1900 PLUMBING FINAL
9002 ROUGH -IN GAS PIPING
8005 ROUGH -IN PLUMBING
9001 UNDERGROUND
CITY OF TUKWI%*
Community Developnte11,10epartment
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.�ov
PLUMBING / GAS PIPING PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print**
SITE LOCATION
%`f� King Co Assessor's Tax Na.:
Site Address: / ! (� el,% Suite Number: Floor:
Tenant Name: New Tenant: ❑ Yes ❑.. No
State: Zip: 7 8/64_
CONTACT PERSON �- person receiving all priij
communication
Name:
Address:
etc'
City:
State:
Zip:
Phone20 23`( 35Jl Fax:
Email:
PLUMBING CONTRACTOR INFORMATION.
Company Name:11 6 e c At /bf
Address: 21 2_6 S 41 1.
City: Des /17 0t 1%., State: (A)" Zipferi �7
Phone:70 6 22, ? c.,6si Fax:
Contr Reg No.: 2( �6.kiznL Ay e
Tukwila Business License No.:
r
Valuation of Project (contractor's bid price): $ �j (J(.)
Scope of Work (please provide detailed information): J ou 6/%6I w-
Building Use (per lnt'l Building Code):
Occupancy (per Int'I Building Code):
Utility Purveyor: Water:
Sewer:
H:\ApplicationsWorms-Applications On Line \20I 1 Applications\Plumbing Permit Application Revised 8-9-I Ldocx
Revised: August 2011
bh
Page 1 of 2
Indicate type of plumbing fixtures and/ts piping outlets being installed and the quanti low:
Fixture Type
Qty
Bathtub or combination
bath/shower
Dishwasher, domestic with
independent drain
Shower, single head trap
Sinks
Rain water system — per
drain (inside building)
Grease interceptor for
commercial kitchen (>750
gallon capacity)
Each additional medical
gas inlets/outlets greater
than 5
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections (1-5)
Fixture Type
Qty
Bidet
Drinking fountain or water
cooler (per head)
Lavatory
Urinal
Water heater and/or vent
Repair or alteration of
water piping and/or water
treatment equipment
Backflow protective device
other than atmospheric -
type vacuum breakers 2
inch (51 mm) diameter or
smaller
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections over 5
Fixture Type
Qty
Clothes washer,
domestic
Food -waste grinder,
commercial
Wash fountain
Water closet
Industrial waste
treatment interceptor,
including trap and vent,
except for kitchen type
grease interceptors
Repair or alteration of
drainage or vent piping
Backflow protective
device other than
atmospheric -type
vacuum breakers over 2
inch (51 mm) diameter
Gas piping outlets
Fixture Type
Qty
Dental unit, cuspidor
Floor drain
Receptor, indirect waste
Building sewer and each
trailer park sewer
Each grease trap
(connected to not more
than 4 fixtures - <750
gallon capacity
Medical gas piping
system serving 1-5
inlets/outlets for a specific
gas
Each lawn sprinkler
system on any one meter
including backflow
protection devices
PERMIT APPLICATION:` NOTES
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing
and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING�D R IZED AGENT: -
Signature: Date: fJ 1 2-1/
�I�tJt t
Print Na Day Telephone: G OCR `t 3�i /
Mailing Address: /1-/6f k0 j % (J((w, l r — G 8
City State Zip
H:\Applications\Forms-Applications On Line\2011 Applications\Plumbing Permit Application Revised 8-9-1 l.docx
Revised: August 2011
bh
Page 2 of 2
Receipt Number
DESCRIPTIONS
PermitTRAK
ACCOUNT
QUANTITY I
PAID
$138.43
PG19-0113 Address: 14480 58TH AVE S Apn: 336590 75
$138.43
Credit Card Fee
$4.03
Credit Card Fee
R000.369.908.00.00
0.00
$4.03
PLUMBING
$128.00
PERMIT FEE
R000.322.100,00,00
0.00
$93.00
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
0.00
$35.00
TECHNOLOGY FEE
$6.40
TECHNOLOGY FEE
TOTAL FEES PAID BY RECEIPT: R18307
R000.322.900.04.00 0.00
$6.40
$138.43
Date Paid: Monday, August 12, 2019
Paid By: PAUL D'OYLEY
Pay Method: CREDIT CARD 138.43
Printed: Monday, August 12, 2019 7:45 AM 1 of 1
SYSTEMS
CO nUKWILA [TRAKIT
5280 SOUTx[EmTER BLVD
TUKWILA' WA 98188
206'439'1870
CITY OF TUKWIL4
Date: 08/12/20I9 07:44:42 AM
CREDIT [4KD SALE
MASTERCARD
CARD NUMBER: **********3128 K
TnAw AMOUNT: $138.43
APPROVAL CV: 832787
RECORD #: 080
CLERK ID: kandace
Thank you!
Customer Copy
Rachelle Ripley
From:
Sent:
To:
Cc:
Subject:
Hi Richard,
• Rachelle Ripley
Monday, August 12, 2019 9:04 AM
Richard Takechi
Kandace Nichols
Refund PG19-0113
A permit was issued in error. It was issued by DCD when it should have been issued by PW. Please refund the credit card
$138.43, paid by The Sewer Doctor, LLC.
Permit #PG19-0113
D'Oyley Residence
14480 58th Ave S
Tukwila, WA 98168
Thank you,
Rachelle Ripley
Permit Coordinator
City of Tukwila
206-433-7165
Rachelle.RipleyTukwilaWA.qov I http://www.TukwilaWA.gov
Contact
Safety & Health Claims & Insurance
Ck Washington State Department of
i Labor & Industries
[Search L&I
Search
A-Z. Index elf) My I .&:1
Workplace Rights Trades & Licensing
SEWER DOCTOR LLC, THE
Owner or tradesperson
Principals
HELM, JOHN DAVID, PARTNER/MEMBER
Doing business as
SEWER DOCTOR LLC, THE
WA UBI No
603 082 513
2126 SO 254TH PL
DES MOINES, WA 98198
206-227-8681
KING County
Business type
Limited Liability Company
Certifications & Endorsements
OMWBE Certifications
No active certifications exist for this business.
Apprentice Training Agent
Not allowed to have apprentices.
License
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Construction Contractor Active,
Meets current requirements.
License specialties
GENERAL
License no.
SEWERDL895CA
Effective — expiration
02/01/2011— 08/07/2021
Bond
Lexon Ins Co
Bond account no.
9803867
$12,000 00
Received by L&I Effective date
05/19/2014 05/19/2014
Expiration date
Until Canceled
Bond history
Insurance
Security National Insurance $1,000,000,00
Policy no.
NA1089157-04
Received by L&I Effective date
08121/2018 08/14/2018
Expiration date
08/14/2019
Insurance history
Help us improve
Savings
No savings accounts during the previous 6 yea, period.
Lawsuits against the bond or savings
No lawsuits against the bond or savings accounts during the previous 6 year period.
L&I Tax debts
No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts
may be recorded by other agencies.
License Violations
No license violations during the previous 6 year period.
Workers' comp
Public Works Requirements
Workplace safety and health
Dcr ft USe. Stlb!ec! Jaws of !he. f,tfitt', or
Help us improve