Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL19-0248 - GENERAL INSULATION COMPANY - INTRUSION ALARM CONTROL PANEL, CELLULAR COMMUNICATION, ETC
GENERAL INSULATION COMPANY 410 ANDOVER PARK E ELI 9-0248 I ~ m ^ Tukwila *° ~ v o o vx oa Department of Community Development 63OOSouthcenterBoulevard, Suite #1OU Tukwila, Washington 981O8 Phone:2O6-431'3670 Inspection Request Line: 206-438-9360 VVobmite:http://wxvw.Tukmi|aVVA.gov ELECTRICAL OTC PERMIT Parcel No: 0223400071 Project Name; GENERAL INSULATION COMPANY Permit Number: EL19'0248 Issue Date: 3/25/2019 Permit Expires On: 9/21/2019 Owner: Name: Contact Person: Name: ]USTINJAME5 ''' Contractor: Name: POBOX 3O42,BO[ARATON'FL, 33431 License No: Lender: Name: Phone: (425)656-8500 Phone: (561)220'8220 Expiration Date: 8/23/2019 DESCRIPTION OFWORK: REMOVE EXISITING ALARM/DEVICES EXCLUDING EGREE DOOR CONTACT IF IN WORKING CONDITION(RE- USECONTACTS IF WORKING CONDITION). INSTALL INTRUSION ALARM CONTROL PANEL (V20), CELLULAR COMMUNICATION IN WAREHOUSE ON TELEPHONE WOOD BOARD AND CONNECT. INSTALL HONEYWELL KEYPAD ON EXTERIOR WALL OF OFFICE IN WAREHOUSE AND CONNECT ALARM PANEL. INSTALL HONEYWELL WIRELESS RECIEVER (5881ENM) IN EXT. WALL OF OFFICE. INSTALL INTERIOR HORN. INSTALL WIRELESS EGRESS DOOR CONTACTS AND MOTION CENSORS. VERIFY ALARM DEVICES ARE REPORTING BACK, ADDITIONAL REPEATER MAY BE ADDED TO BOOST SIGNALS.Valuation ofsingle family: $I00 Valuation ofmf/cnmm: $2'404.00 TypeofVVork: L0VVVOLTAG[ Fees Collected: $15015 Electrical Service Provided by: PUGETSOUND ENERGY Water District: TUKVV|LA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: international Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: VVACities Electrical Code: VVA[Z9646B: nergy Code: �� �� ����'��� Permit Center Aut Authorized I|Ona �0��� �,��&C�c�� -^/I*���8/ y �� Date: �~ �— -^ / � |heorbycertify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state orlocal laws regulating construction orthe performance ofwork. |amauthorized tosign and obtain this development permit andagree tuthe c"~,� �on�attached tothis permit. ~` �� /'_ «-^-Signature: e#1 Date: ���~� ' -� �� Print Name: YL �e This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended orabandoned for operiod ofl8Odays from the last inspection. PERMIT CONDITIONS: 1: 'ELECTRICAL PERMIT [ONDO|ONS~°* Z: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector ateach work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical |nspeoLor. 4: All electrical work shall be inaccordance with NFPA7O' NEC, and requirements for electrical installations, Chapter Z9646BVVA[and the Washington Cities E|eocrica|Code. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance ofanelectrical work permit shall not beconstrued toheapermit for, oranapproval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes uugrant this authority are therefore not valid. 7: Any change inthe scope ufwork described bythe electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206)438'9350 2100 ELECTRICAL FINAL 7003 ROUGH'|NELE[TR/[AL 7002 SERVICE 7001. UNDERGROUND/SLAB CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd , Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Electrical Permit No. ,E1— 19 0 Project No, Date Application Accepted: g*- Date Application Expires: el tc-1 (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: Site Address: 410 Andover Park East, Tukwila WA. 98188 Suite Number: Floor: Tenant Name: General Insulation Company PROPERTY OWNER Name: Address: 410 Andover Park East City: Tukwila State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: Justin James Address: City: State: Zip; Phone: Fax: 425-656-8500 Email: ijamesacieneralinsulation.com New Tenant: LJ .....Yes ca „No ELECTRICAL CONTRACTOR INFORMATION Company Name: Johnson Controls Address: 19625 62nd Ave. South Suite C112 City. Kent State: WA Zip:98032 Phone: 425-656-8500 Fax: Contr Reg No.: JOH NSC837N4 Exp Date: 08/2020 Tukwila Business License No.; BUS-0993778 5c sss Valuation of Project (contractor's bid price): $ 2404.00 Scope of Work (please provide detailed information): Remove exisiting alarm/devices excluding egree door contact if in working condition (re -use contacts if working condition). Install intrusion alarm control panel (v20), cellular communication in warehouse on telephone wood board and connect. Install Honeywell keypad on exterior wall of office in warehouse and connect alarm panel. Install Honeywell wireless reciever(5881EMM) on ext. wall of office. Install interior horn. Install wireless egress door contacts and motion sensors. Verify alarm devices are reporting back, additoinal repeater may be aded to boot signals. Will service be altered? Type of Use: Type of work: El New 0 Low Voltage Property Served by: 111 Puget Sound Energy El Yes No Adding more than 50 amps? 0 Yes JZJ No ED Addition LI Generator O Service Change o Fire Alarm Seattle City Light EI Remodel Telecommunication 0 Tenant Improvement Temporary Service W:lPerrnit Center \ Applications-HandoutsTennit Applications \ PDFalectrical Permit Application Revised 1-17-19.docx Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE LI New single family dwellings $180.00 (including an attached garage) El Garages, pools, spas and outbuildings $120.00 ea El Low voltage systems (alarm) $60.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES O Service change or alteration $120.00 (no added/altered circuits) O Service change with added/altered circuits $100.00 number of added circuits $10.00 ea O Circuits added/altered without service change $60.00 (up to 5 circuits) O Circuits added/altered without service change $60.00 (6 or more circuits) $10.00 ea 0 Meter/mast repair $80.00 Ej Low voltage systems $60.00 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES • Temporary service (residential) $60.00 O Temporary service (generator) $90.00 0 Manufactured/mobile home service $100.00 (excluding garage or outbuilding) El Carnivals $100.00 Number of conc.essions $11.00 ea Each ride and generator truck $11.00 ea ***EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: //(h474 Date: *gai( Print Name: c_e \laktiIC Day Telephone: 21-3 lq(/ Mailing Address: We314d 4Ve- S aiD"k?(/I City State State Zip WAPermit Center\ Applications -Handouts \ Permit Applications \PDF's \ Electrical Permit Application Revised t-t 7-19,docx Page 2 of 2 Cash Register Receipt City of Tukwila Receipt Number DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $150.15 EL19-0248 Address: 4 0 ANDOVER PARK E Apn: 0223400071 $150.15 ELECTRICAL $143.00 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $143.00 TECHNOLOGY FEE $7.15 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R17234 R000.322.900.04.00 0.00 $7,15 $150.15 Date Paid: Monday, March 25, 2019 Paid By: TYCO INTEGRATED SECURITY Pay Method: CHECK 015133 Printed: Monday, March 25, 2019 10:40 AM 1 of 1 Y5TEMS INSPECTION NO. INSPECTION RECORD Retain a copy with permit PRI'IIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Btvd., #100, Tukwila. WA 98188 (206) 431 Permit Inspection Request Line (206) 438-9350 Project: �,'v�i�t.�' ��V✓' YPe of Inspection: _ /` n!i''' V 1 Address: o Date Called: Special Instructions: �,. RAT ' Date Wanted: a.rn. p.m. Requester: Phone No: 3 77(0 75.7 . Approved per applicable Lodes. 11 Corrections required prior to approval. COMMENTS: Inspector: Date: REINSPECT#© FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Btvd.. Suite 100. Call to schedule reinspection. City of Tukwila Department of Community Development 8/5/2019 JUSTIN JAMES RE: Permit No. EL19-0248 GENERAL INSULATION COMPANY 410 ANDOVER PARK E Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 9/21/2019. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 9/21/2019, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Since ly, K ndace Nichols2 Permit Technician File No: EL19-0248 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 Rome Espanol Contact Search L&I Safety & Health Claims & Insurance 411111111k Washington State Department of / Labor & industries A-Z index Ltelp My 1&1 Workplace Rights Trades & Licensing JOHNSON CONTROLS SEC SOL LLC Owner or tradesperson Principals OLIVER, JOSEPH, PARTNER/MEMBER MAXIE, ROBERT C, PARTNER/MEMBER MCGRAW, ANTHONY, PARTNER/MEMBER CT CORPORATION SYSTEMS, AGENT Doing business as JOHNSON CONTROLS SEC SOL LLC WA UBI No. 601 636 830 ATTN LICENSING DEPT PO BOX 3042 BOCA RATON, FL 33431 561-226-8220 Business type Limited Liability Company Governing persons US HOLDINGS LLC TYCO FIRE & SECURITY NELSON D BLEISCH; MAGIN A FAXAZ; ROBERT C MAXIE; DANIEL J MCGRATH; ANTHONY MCGRAW; MARK VAN DOVER; icense Verify the contractor's active registration / license / certification (depending on trade) and any past violations, Electrical Contractor Active. Meets current requirements. License specialties LIMITED ENERGY License no. JOHNSCS837N4 Effective — expiration 08/23/2017— 08/23/2019 Designated administrator Parrett, Leslie R License type Electrical Administrator Bond Federal Ins Co Bond account no. 82302097 Active. Meets current requirements. License no. PARRELR860QL $4,000.00 Received by L&I Effective date 08/14/2017 06/28/2017 Expiration date Until Canceled Savings No savings accounts during the previous 6 year period. Help us improve /684 License Violations No license violations during the previous 6 yer-wdenod. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. This company has multiple workers' comp accounts. Active accounts L&I Account ID 700,424-00 Doing business as JOHNSON CONTROLS Estimated workers reported N/A L&I account contact (360)902-4817 Track this contractor 0 Self Insured. This business is certified to cover its own workers' comp costs. No premiums due. Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 02/17/2015 Inspection no. 317935053 Location 925 S Mission Wenatchee, WA 98801-3015 Violations .:-.VVashingluit State Dept. of Labor & industries. Use of this site is subject to the laws of the state of Washloglon Help us improve