Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL19-0673 - STEPHAN HEED - PV SYSTEM ON ROOF. 25 QCELL 385W MODULES AND 1 SOLAREDGE 7600 INVERTER.
STEPHAN HEED 13608 34T" AVE S EL1 9-0673 Parcel No: Address: Project Name: City of Tukwila a Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www,TukwilaWA.gov 8864000145 13608 34TH AVE 5 STEPHAN HEED ELECTRICAL PERMIT Permit Number: EL19'0673 Issue Date: 8/28/2019 Permit Expires On: 2/24/2020 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: HEED STEPHEN 13608 34TH AVE S , TUKWILA, WA 98168 D|CK50NHARD|NG 828POPLAR PLS'SEATTLE, WA, 98144 5 M E INC OF SEATTLE D2OPOPLAR PLS'SEATTLE, WA, 98144-2828 5ME|NS°066D8 ''' Phone: (206) 391-2603 Phone: (206) 329-2040 Expiration Date: 3/2/2020 DESCRPTION OF WORK: PV SYSTEM ON ROOF. 25 QCELL 385W MODULES AND 1 SOLAREDGE 7600 INVERTER. Valuation of single family: $1,000.00 Valuation of mf/comm: $0.00 Type ofWork: ADDITION Fees Collected: $78.00 Electrical Service Provded by: SEATTLE CITY LIGHT Water District: 125 Sewer District: VALLEY VIEW Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 20152015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: Date: 2017 20172017 2015 |hearbycertify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or Iocal laws regulating constructiori or the performance of work. 1 am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: Date: 2-5777 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work 15 suspended or abandoned for a period of 180 days from the last irlspection. PERMIT CONDITIONS: 1: ***ELECTRICAL PERMIT CONDITIONS*** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical lnspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shaH be in accordance with NFPA 70 NEC, and requirements for electrical installations, Chapter 296-46B WAC and the Washington Cities Electrical Code. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction, Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKV Community Developme Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Electrical PeQit No. r Project No, Date Application Accepted: Date Application Expires: oroizce use onlv ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: 8864000145 13608 34th Ave South n/a Site Address: Suite Number: Floor: "a Stephan Heed Tenant Name: New Tenant: Yes 0..No PROPERTY OWNER Name: Dickson Harding Name: Stephan Heed Phone: 206.391.2603 Fax: Address: 13608 34th Ave South City: Tukwila State: WA Zip: 98168 CONTACT PERSON — person receiving all project communication Name: Dickson Harding Address: 828 Poplar P1. S CitY: Seattle state: WA Zip:98144 Phone: 206.391.2603 Fax: Email: dicksonh@nwwindandsolar.com ELECTRICAL CONTRACTOR INFORMATION Company Name: NW Wind & Solar Address: 828 Poplar P1. S City: Seattle State: WA Zip: 98144 Phone: 206.391.7010 Fax: Contr Reg No.: SMEINS*066DB Exp Date: 3/2/20 Tukwila Business License No.; BUS -0994361 Scope of Work (please provide detailed information): PV system on roof . 25 QCell 385W modules and 1 SolarEdge 7600 inverter Will service be altered? E Yes E] No Adding more than 50 amps? E:::] Yes ED No Type of Use: Type of work: 0 New M Addition 0 Service Change 0 Remodel 0 Tenant Improvement 0 Low Voltage EJ Generator LJ Fire Alarm 0 Telecommunication El Temporary Service Property Served by: Puget Sound Energy M Seattle City Light W: \Permit CenteriApplications-HandoutstPennit Applications,PDF's\ Electrical Permit Application Revised I-17-19.docx Pagela2 RESIDENTIAL NEW RESIDENTIAL SERVICE O New single family dwellings $180.00 (including an attached garage) LI Garages, pools, spas and outbuildings 5120.00 ea O Low voltage systems (alarm) 560,00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES O Service change or alteration $120.00 (no added/altered circuits) 0 Service change with added/altered circuits__ $100.00 number of added circuits $10.00 ea [i] Circuits added/altered without service change 560.00 (up to 5 circuits) Circuits added/altered without service change 560.00 (6 or more circuits) $10.00 ea O Meter/mast repair $80 00 O Low voltage systems ....... ......... ...... 560.00 (alarm, furnace thermostat) • MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES O Temporary service (residential) $60.00 O Temporary service (generator) $90.00 O Manufactured/mobile home service 5100.00 (excluding garage or outbuilding) O Carnivals • 5100.00 Number of concessions $11.00 ea Each ride and generator truck $ 11.00 ea ***EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated, I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL, CONTRACTOR: Signature: Mt) 44.1 S PM Date: :32C-31// Di. son Harding 206.39f.2603 Print Nanie: Day Telephone: Mailing Address: 828 Poplar Pl. S Seattle WA 98144 City WAPerinit Center Applications -Handouts \ Permit ApplicatiORS'PDFstElectrical Permit Application Revised I -1 7-19.docx stats Zip Page2a2 Receipt Number City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $78.00 E119-0673 Address: 13608 34TH AVE S Apn: 8864000145 $78.00 ELECTRICAL $75.00 PLAN CHECK FEE R000.345.832.00.00 0.00 $15,00 PERMIT FEE SINGLE FAMILY R000.322,101.00.00 0,00 $60.00 TECHNOLOGY FEE $3.00 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R18382 R000.322,900,04.00 0.00 $3.00 $78.00 Date Paid: Wednesday, August 21, 2019 Paid By: SME, INC OF SEATTLE Pay Method: CHECK 25126 Printed: Wednesday, August 21, 2019 8:51 AM 1 of 1 SYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. T N CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit inspection Request Line (206) 438-9350 Pro ec : Type o$,f1nspec on: Address: Date Cal d: Special Instructions: Cfril,t, 1-0 s sr. 3 0 'Date Wanted: a.m. p.m. No: SiiPhone Approved per applicable codes. Ei Corrections required prior to approval. OMMENTS: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO, INSPECTION RECORD Retain a copy with permit P"' MIT Ni CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: � -- Type of Inspection: Address: Date Cal edif: Special instructions: Date Wanted: P.m. Requester: Phone No: `., ,, tiJ 3 ct i Q, LJApproved per applicable codes. Corrections required prior to approval. COI IMENTS: ... I REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. UTILITY NET METER T HOUSE PANEL 200A MCB, 240/120V, 10,3 Uire, l 46Aux GEC — INSTALL BREAKER AT OPPOSITE END OF BUS AS MAIN BREAKER. RACK CONNECTION [2410, 1 410EGC, 1 46GEC THWN, 314' EMT]CU [348 THWN, 48 GEC, 314' EMT ICU PRODUCTI METER n 1 IOW 111111;111111111111 111111111111-111111 111111111111111111 1111111110111111 111111111111111111 NMI sHIM D111 11111I'11011111111 111111111111'111111 WWI 10011001 2410 CU USE.2 [2410,1 I (PV CABLE, rte, 410 EGC, dNaa, TYPI. THWN 314, EMT ICU J REVISIONS SHEET NOTES D,M000LE•SEE RVMALE SCHEELE, NEMA IR WA SAFETY DISCONNECT WITH VEBLE RAP /• LOCKABLE TYPE CO.LOCATEO 114 PRODUCTION METE {UTILITY REOUREMENTI 7' 46 BANE CU GROUND WIRE OR YVEESE/ AS1ER ELECTRICAU EOUIRw4ENT EONDI, NOTUSEO. 6� PRODUCTION METER, SEE METER SOCKET WIRING V DIAGRAM ON THIS E MET CO{0CATED 4801 NET NETER, BLACK ( (RED PHASE Ar PHASE B WHITE NEUTRAL METER SOCKET WIRING DIAGRAM --a — --� J' _ .J:_ •J .I. .L. JL. .y .y NO CI',5noes silail bo nine 10 me scope of work wltnoul o ^o: apaloval of the Tukwila Building DIviS[aT NOTE: Revisions will reduce a new olan submittal and may Include aa0'Itional plan review. :' POWER OPTIMIZER SHOTS OFF DC OUTPUT AT TH: PV NOODLE SATISFYING REQUIREMENTS OF RAPIQ 5i0TD0WN. Plan rem approval is sob to errors and omrssons Approval of construction aocumenls does iol author¢e pie violation Of any aaopled code Or ordinance Recent of approved Fla Copy' and condiripAsl acpnowleagea: Oates: City I Tu4wila BUILDING DIVISION System Grounding Type (NEG, POS, 55): Conductor Insulation Colors Negatve: NEG P05u G While or Gray Black Black Inverter(s) on Root YO NZ Positive: Red Wh'de or Gray Red 480 -Volt System wit GFP: YES 0 `i.�i r—i • t a I I I err r=r--r —LABEL PER 690.53 (1) (2) (3) (4) 111111.111111:111111111111 11111 01111111111 111111 HMI>111111'-111111 111111 111111 HMI NMI ^ H1111 111111 11111 HUH WM HMI 11111 111111111111 11011 11111 111111111111111111 Ir,Hr ruru mumran mac: .ALS. 1@. .1E. STRING NUMBER(S 1 NUMBER OF MODULES IN SERIE 25 NUMBER OF STRINGS IN PARA LE 1 STRING POWER(KWDC 0.63 MAX POWER POINT CURRENT - IMPP(A 9.61 MAX POWER POINT VOLTAGE(V 350.00* MAX STRING VOLTAGE(V 500.0' MAX CIRCUIT CURRENT(ISC*1.25*L25)(A 15.78 CONTROLLED BY OPTIMIZER' UL -1741 INVERTER NUMBER 1 INVERTER MME SOLAREDGE MODEL SE1600H•11S DC INPUT___ 25 MAX INPUT VOLTAGE(V) 480 MAX POWER PER INPUT(W) 11,800 INPUT VOLTAGE RANGE(V) 380-480 MAX INPUT CURRENT(A) 20 ____-AC OUTPUT___ -0.28 OUTPUT VOLTAGE RANGE(V) - NOMINAL OUTPUT VOLTAGE(V) 240 MAX CONTINUOUS OUTPUT CURRENT(A) 32.0 MAX CONTINUOUS POWER OUTPUT(W) 1,600 \, 11111 .-J• YOUR ENER&"( APC HITEC1S 828 POPLAR PLACE SOUTH SEATTLE, WA 98144 PHONE: (206) 587-6527 FAX: (206) 726.8160 WWW.NWWINDANDSOLAR.COM NW WIND 6 SOLAR IS A DIVISION OF SME INC, OF SEATTLE PROD, MGR,: Dickson Harding DESIGN BY: Dallas Anderson, PE PROJ. No.: 19-W64 PROJECT TITLE: -SEPA" PERMIT REQ IRED FOR: I Eleabk�l Plumbing Gas Piping Ci y of Tukila BUILDING DIVISION SYSTEM VOLTAGE 6 PHASE(V, I DR 3) 240-1 SYSTEM SIZE(KWDC) 9.63 MAX NUMBER OF MODULES PER STRING 25 TOTAL NUMBER OF MODULES 25 TOTAL NUMBER OF INVERTERS 1 LOWEST EXPECTED AMBIENT TEMP(°C) -10 HIGHEST EXPECTED AMBIENT TEMP(°C) 36 STANDARD TEST CONDITIONS(°C) 25 PV MODULE MAKE QCELL MODEL 385W MAX POWER • PMAX(W) 385 MAX POWER POINT VOLTAGE • VMPP(V) 40.05 MAX POWER POINT CURRENT • IMPP(A) 9.61 OPEN CIRCUIT VOLTAGE • VOC(V) 48.21 SHORT CIRCUIT CURRENT • ISC(A) 10.10 TEMP COEFFICIENT PMPP(%I°C) -0.37 TEMP COEFFICIENT VOC(%1°C) -0.28 TEMP COEFFICIENT ISC(1°C) ;,;4 MAX MODULE VOLTAGE(V) ,1t lip FO OON PLU�NC€,W NPA 0 • NEC 6627fQnil Cy of Tukwila BOKtiNIL_DING DIVISION EIV;) TUA Els)q,0471 AUG Z 1 ZJ19 ,= Ca ER SHEET TITLE; STEPHAN HEED'S 9 630 PHOTOVOLTAIC SYSTEM DATE: 08102/19 SCALE: as noted PROJECT SITE: 13608 34TH AVE SOUTH TUKWILA, WA 98168 PV RISER AND SCHEDULES REV. No.: 0 ellIMIallaiememmegger SHEET NUMBER: PV1 Solar Array 1 6 Solar Modules Poch: 20 Deg Orientation: 250 D Solar Array 2 12 Solar Modules Pilch: 20 Deg Orientation: 250 De Solar Array 3 7 Solar Modules Pitch: 20 Deg Odentation: 160 De Note: Solar module layout as depicted is based on initial site survey. Final system design configuration may vary from drawing. Proposed layout includes racking space requirements RECEIVED CITY OF TUKV ILA A16 212019 dERMIT CENTER J1 YOUR ENERGY ARCHITECTS.' Roof Mounted Solar PV system Preliminary Layout Project Name : Heed Solar Project address: 13608 34th Ave S Tukwila, WA 98168 (25) 72 cell - Solar Modules grrD FSO' N PO EC MI8 271019 CNy of TulcOla 6LILDING DIVISION 0° Dormer Vent Solar Module 3' setback Drawn By: David Durger Date: 0811312019 OF TU!KWILA AUG 21 2019 CENTER E FO NFPTH A70 -NE AUG 2 7 2019 City of Tukwila DUILDING DIVISION Phntnn 1 J Q.AN powered by TUM /DUO/ The new high-performance module Q.PEAK DUO L -G5.3 is the ideal solution for commercial and utility applications thanks to a combina- tion of its innovative cell technology Q.ANTUM and cutting edge cell interconnection. This 1500V IEC/UL solar module with its 6 busbar cell design ensures superior yields with up to 395 Wp while having a very low LCOE. SII etel 0 LOW ELECTRICITY GENERATION COSTS Higher yield per surface area, lower BOS costs. higher powe classes, and an efficiency rate of up to 19.9%. INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields, whatever the weather with excellent low -light and temperature behavior. ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID Technology, Anti PID Technology', Hot -Spot Protect and Traceable Quality Tra.QTM' EUPD RESEARCH EXTREME WEATHER RATING TOP MUM PY High-tech aluminum alloy frame, certified for high snow (5400 Pa) and wind loads (2400 Pa). 2o1 2018 A RELIABLE INVESTMENT Inclusive 12 -year product warranty and 25 -year linear performance warranty2. THE IDEAL SOLUTION FOR: Rooftop arrays on Ground -mounted commercial/industrial solar power plants buildings Engineered in Germany RECEIVED CITY OF TUKWILA AUG 2 1 2019 PERMIT CENTER uCEILS Mn no =MOM urn ✓roT PROTECT txsrl iTR*CEMLt ouaurr mue••l .71.51.151) TIM01.03, am UCELLS Best polycrystalline solar module 2014 a.veo-cµ 235 174 I APT fest conditions according to IEC/TS 62804-1:2015, method B (-1500V, 168h) 2 See data sheet on rear for further information. ELJO(o"73 taus MECHANICAL SPECIFICATION Format Weight Front Cover 2015mm x 1000mm x 35mm (including frame) 23 kg 3.2mm thermally pre -stressed glass with anti -reflection technology Back Cover Composite film Frame Anodised aluminium Cell 6 x 24 monocrystalline Q.ANTUM solar half cells Junction 70-85mm x 50-70mm x 13-21mm box Protection class IP67, with bypass diodes Cable 4mm2 Solar cable; (+) a 1350mm, (-) 21350mm Connector Multi -Contact MC4-EV02, JMTHY PV-JM601A, IP68 or Renhe 05.8, IP67 9. -I I-39mm OM/A 11 Am I--1 :s.s..I�Iasaa^ OETA19 IOmm �1 :sP,.IOI9.. ELECTRICAL CHARACTERISTICS POWER CLASS 380 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC (POWER TOLERANCE +5W /-OW) E E Power at MPP° Short Circuit Current* Open Circuit Voltage* Current at MPP* Voltage at MPP* Efficiency' PAPP ISC Vo' IAPP yMPP n [WI [A] [V] [Al [VI [%1 380 10.05 47.95 9.57 39.71 2 18.9 385 10.10 48.21 9.61 40.05 2 19.1 390 390 10.14 48.48 9.66 40.38 -:19.4 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS. NOC Power at MPP' PAPP [W1 281.6 285.3 289.0 E Short Circuit Current* ISC [A] 8.11 8.14 8.18 E E Open Circuit Voltage* Vac [V) 44.85 45.10 45.35 f Current at MPP* IMP. [Al 7.53 7.56 7.60 Voltage at MPP* VAPP [V] 37.41 37.73 38.04 1000W/m', 25°C, spectrum AM 1.5G 'Measurement tolerances STC ±3%; NOC ±5% 3800W/m2, NOCT, spectrum AM 1.5G 'typical values, actual values may differ Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE ccs ,u..w,nw.a ier anw..i,a,on - 110t, 0.00 Perel 13 10 ,P, el 3mn160•.ne 10 P9 cans., .n vv1,0.eeu:01,a0.1ry n 3014,. a: Wena,' 3014, 01400 At least 98% of nominal power during first year. Thereafter max. 0.54% degradation per year. At least 93.1 % of nominal power up to 10 years. At least 85% of nominal power up to 25 years. All data within measurement tolerances. Full warranties in accordance with the warranty terms of the Q CELLS sales organization of your respective country. TEMPERATURE COEFFICIENTS Temperature Coefficient of Igo a [%/K1 Temperature Coefficient of PAPP y [%/K) �. no is 5 aq 200 100 600 Aq lo® IRRADIANCE IW/M. 1 Typical module performance under low irradiance conditions in comparison to STC conditions (25'C, 1000W/m'). +0.04 Temperature Coefficient of Voc -0.37 Normal Operating Cell Temperature iP NOCT 395 395 10.19 48.74 9.70 40.71 219.6 292.7 8.22 45.60 7.63 38.35 [%/K1 -0.28 [°C] 45±3 PROPERTIES FOR SYSTEM DESIGN Maximum System Voltage Maximum Reverse Current Push/Pull Load (Test -load in accordance with IEC 61215) 1500 Safety Class 20 Fire Rating 5400/2400 Permitted Module Temperature On Continuous Duty I I C -40°C up to +85°C QUALIFICATIONS AND CERTIFICATES PARTNER IEC 61215 (Ed.2); IEC 61730 (Ed. 1), Application class A This data sheet complies with DIN EN 50380. CE NOTE: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product. Hanwha G CELLS GmbH Sonnenallee 17-21. 06766 Bitterfeld-Wolfen, Germany I TEL +49 (0)3494 66 99-23444 I FAX +49 (0)3494 66 99-23000 I EMAIL sales@q-cells.com I WEB www.q-cells.com f �1. $ Engineered in Germany , iA' 39 • QCELLS z bject to technical changes 0 Hanwha 0 CELLS Q.PEAK DUO L -G5.3 380-395_2018-08 00 A mm 93 1308 400 A. 1 j • a.c.,.0nsnwE.60.36"140001 ✓ e. wmnoa n+.e 3*6.,.,• A. Aans.s AIWA 400:40,10E111E 81 0,4.° Pm. 9N.n o- AA 110.00 data03EnAIL Al CI °, 100 . - 1 B.pAAPesw. 3.emm- -I I-39mm OM/A 11 Am I--1 :s.s..I�Iasaa^ OETA19 IOmm �1 :sP,.IOI9.. ELECTRICAL CHARACTERISTICS POWER CLASS 380 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC (POWER TOLERANCE +5W /-OW) E E Power at MPP° Short Circuit Current* Open Circuit Voltage* Current at MPP* Voltage at MPP* Efficiency' PAPP ISC Vo' IAPP yMPP n [WI [A] [V] [Al [VI [%1 380 10.05 47.95 9.57 39.71 2 18.9 385 10.10 48.21 9.61 40.05 2 19.1 390 390 10.14 48.48 9.66 40.38 -:19.4 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS. NOC Power at MPP' PAPP [W1 281.6 285.3 289.0 E Short Circuit Current* ISC [A] 8.11 8.14 8.18 E E Open Circuit Voltage* Vac [V) 44.85 45.10 45.35 f Current at MPP* IMP. [Al 7.53 7.56 7.60 Voltage at MPP* VAPP [V] 37.41 37.73 38.04 1000W/m', 25°C, spectrum AM 1.5G 'Measurement tolerances STC ±3%; NOC ±5% 3800W/m2, NOCT, spectrum AM 1.5G 'typical values, actual values may differ Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE ccs ,u..w,nw.a ier anw..i,a,on - 110t, 0.00 Perel 13 10 ,P, el 3mn160•.ne 10 P9 cans., .n vv1,0.eeu:01,a0.1ry n 3014,. a: Wena,' 3014, 01400 At least 98% of nominal power during first year. Thereafter max. 0.54% degradation per year. At least 93.1 % of nominal power up to 10 years. At least 85% of nominal power up to 25 years. All data within measurement tolerances. Full warranties in accordance with the warranty terms of the Q CELLS sales organization of your respective country. TEMPERATURE COEFFICIENTS Temperature Coefficient of Igo a [%/K1 Temperature Coefficient of PAPP y [%/K) �. no is 5 aq 200 100 600 Aq lo® IRRADIANCE IW/M. 1 Typical module performance under low irradiance conditions in comparison to STC conditions (25'C, 1000W/m'). +0.04 Temperature Coefficient of Voc -0.37 Normal Operating Cell Temperature iP NOCT 395 395 10.19 48.74 9.70 40.71 219.6 292.7 8.22 45.60 7.63 38.35 [%/K1 -0.28 [°C] 45±3 PROPERTIES FOR SYSTEM DESIGN Maximum System Voltage Maximum Reverse Current Push/Pull Load (Test -load in accordance with IEC 61215) 1500 Safety Class 20 Fire Rating 5400/2400 Permitted Module Temperature On Continuous Duty I I C -40°C up to +85°C QUALIFICATIONS AND CERTIFICATES PARTNER IEC 61215 (Ed.2); IEC 61730 (Ed. 1), Application class A This data sheet complies with DIN EN 50380. CE NOTE: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product. Hanwha G CELLS GmbH Sonnenallee 17-21. 06766 Bitterfeld-Wolfen, Germany I TEL +49 (0)3494 66 99-23444 I FAX +49 (0)3494 66 99-23000 I EMAIL sales@q-cells.com I WEB www.q-cells.com f �1. $ Engineered in Germany , iA' 39 • QCELLS z bject to technical changes 0 Hanwha 0 CELLS Q.PEAK DUO L -G5.3 380-395_2018-08 4 solar - • • SolarEdge Power Optimizer Module Add -On For North America P320/ P370 / P400/ P405/ P505 PV power optimization at the module -level — Specifically designed to work with SolarEdge inverters — Up to 25% more energy — Superior efficiency (99.5%) — Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading — Flexible system design for maximum space utilization • Fast installation with a single bolt — Next generation maintenance with module -level monitoring • Compliant with arc fault protection and rapid shutdown NEC requirements (when installed as part of the SolarEdge system) — Module -level voltage shutdown for installer and firefighter safety USA - CANADA GERMANY - ITALY - FRANCE - JAPAN - CHINA - AUSTRALIA - THE NETHERLANDS - UK - ISRAEL - TURKEY - SOUTH AFRICA - BULGARIA - INDIA www.solaredge.us solar-.. OPTIMIZER MODEL (typical module compatibility) INPUT SolarEdge Power Optimizer Module Add -On for North America P320/ P370/ P400 / P405/ P505 P320 (for high-power 60 -cell modules) P370 (for higher -power 60 and 72 -cell modules) P400 P405 (for thin film modules) (for 72 & 96-c1I modules) P505 (for higher current modules) Rated Input DC Powers" 320 370 400 405 Absolute Maximum Input Voltage (Voc at lowest temperature) MPPT Operating Range 48 60 80 125 8-48 8-60 Maximum Short Circuit Current (Ise) 11 8-80 12.5-105 10.1 Maximum DC Input Current 13 75 Maximum Efficiency Weighted Efficiency Overvoltage Category 505 83 12.5 - 83 14 W Vdc Vdc 12.63 99.5 98.8 I I 17.5 Adc Adc 98.6 OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 15 Maximum Output Voltage 60 85 OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power Optimizer 1 ± 0.1 STANDARD COMPLIANCE EMC Safety RoHS INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage Adc Vdc Vdc Compatible inverters Dimensions (W x L x H) Weight (including cables) Input Connector Output Wire Type / Connector Output Wire Length FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3 IEC62109-1 (class II safety), UL1741 Yes 1000 Vdc All SolarEdge Single Phase and Three Phase inverters 128 x 152 x 28/5 x 5.97 x 1.1 630 / 1.4 0.95 / 3.0 Operating Temperature Range Protection Rating Relative Humidity n) Rated STC power of the module. Module of up to +5% power tolerance allowed U' For other connector types please contact SolarEdge 128x152x36/ 5x5.97x1.42 128 x 152 x 50 / 5 x 5.97 x 1,96 128 x 152 x 59 / 5 x 5.97 x 2.32 mm / in 750 / 1.7 MC4121 845 / 1.9 Double Insulated; MC4 1064 / 2.3 gr/ Ib 1.2 / 3.9 -40 - +85 / -40 - +185 IP68 / NEMA6P 0-100 PV SYSTEM DESIGN USING A SOLAREDGE INVERTERt311"1 SINGLE PHASE HD -WAVE m/ft °C/°F SINGLE PHASE THREE PHASE 208V THREE PHASE 480V Minimum String Length I P320, P370, P400 (Power Optimizers) P405 / P505 Maximum String Length (Power Optimizers) Maximum Power per String Parallel Strings of Different Lengths or Orientations 8 10 18 6 25 5700 (6000 with SE7600H-US) 5250 8 14 25 6000 50151 12750 Yes 13l For detailed string sizing information refer to: http://www.solaredge.com/sites/default/files/string sizing_na.pdf. ("' It is not allowed to mix P405/PSOS with P320/P370/P400/P600/P700/P800 in one string. 151 A string with more than 30 optimizers does not meet NEC rapid shutdown requirements; safety voltage will be above the 30V requirement CE ODI ® SolarEdge Technologies. Inc. AS rights reserved. SOLAREDGE. the SolarEdge logo. OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies. Inc. All other trademarks mentioned herein are track -mat , of their res )ective owners. Date: 02 2018 "VOl ENG NAM. Sub"ect to chane without notice. W Single Phase Inverter with HD -Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US 0 solar„'[ ,1--1 ,... 0 0 0 solar) AID 0 _ �.... 0 0 0 r 0 0 11. 1111, IMP Optimized installation with HD -Wave technology / Specifically designed to work with power optimizers / Record-breaking efficiency / Quick and easy inverter commissioning directly from a smartphone using the SolarEdge SetApp / Fixed voltage inverter for longer strings / Integrated arc fault protection and rapid shutdown for NEC 2014 and 2017, per article 690.11 and 690.12 solaredge.com S}J3J)J3AN / UL1741 SA certified, for CPUC Rule 21 grid compliance / Extremely small / Built-in module -level monitoring / Outdoor and indoor installation / Optional: Revenue grade data, ANSI C12.20 Class 0.5 (0.5% accuracy) solar-•• W Single Phase inverter with HD -Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US Model Number SE30O0H-US SE3800H-US SE5000H-US SE60O0H-US SE760OH-US SE10000H-US SE11400H-US APPLICABLE TO INVERTERS WITH PART NUMBER SEXXXXH-XXXXXBXX.1 OUTPUT Rated AC Power Output 3000 3800 @ 240V 3300 @ 208V 5000 6000 @ 240V 5000 @ 208V ,y00 10000 11400 @ 240V 10000 @ 208V VA Maximum AC Power Output 3000 3800 @ 240V 3300 @ 208V 5000 6000 @ 240V 5000 @ 208V 7600 10000 11400 @ 240V 10000 @ 208V VA AC Output Voltage Min. -Nom. -Max. (211 - 240 - 264) 1 ✓ ✓ ✓ v ✓ 1 Vac AC Output Voltage Min. -Nom. -Max. (183 - 208 - 229) _ 8.5 10.5 13.5 16.5 f_ 4 27 ✓ Vac AC Frequency (Nominal) 59.3 - 60 - 60.5 ' Hz Maximum Continuous Output Current @240V 12 5 16 21 2532 , 42 47.5 A Maximum Continuous Output Current ©208V 16 akaSeiaIvay 24 - 99 1 1' 1 48.5 A Power Factor 1, adjustable -0.85 to 0 85 % GFDI Threshold 1 A Utility Monitoring, Islanding Protection, Country Configurable Thresholds Yes INPUT Maximum DC Power @240V 4650 5900 7750 9300 Plc'. 15500 17650 W Maximum DC Power @208V - 5100 - 7750 * - - 15500 W Transformer -less, Ungrounded ><'`163 . Maximum Input Voltage s 490 Vdc Nominal DC Input Voltage Mk 400 Vdc Maximum Input Current @240V121 8.5 10.5 13.5 16.5 27 30-5 Adc Maximum Input Current @208V12- 9 13.5 27 Adc Max. Input Short Circuit Current 148 Adc Reverse -Polarity Protection t Ground -Fault Isolation Detection akaSeiaIvay Maximum Inverter Efficiency 99 1 1' 1 % CEC Weighted Efficiency --, 99 @ 240V 98.5 @ 208V % Nighttime Power Consumption 'Mr' W For other regional settings please contact So arEdge support A higher current source may be used; the inverter will limit rts input current to the values stated Single Phase Inverter everter with HD -Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US Model Number SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-UIS SE10000H-US SE11400H-US ADDITIONAL FEATURES Supported Communication Interfaces Revenue Grade Data, ANSI 02.20 RS485, Ethernet, ZigBee (optional), Cellular (optional) Optional' Inverter Commissioning with the SetApp mobile application using built-in Wi-Fi Access Point for tical connection Rapid Shutdown - NEC 2014 and 2017 69012 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety UL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07 Grid Connection Standards IEEE1547, Rule 21, Rule 14 (HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG Range 1" Maximum / 14-6 AWG 1" Maximum /14-4 AWG DC Input Conduit Size / # of Strings / AWG Range 1" Maximum / 1-2 strings / 14-6 AWG 1" Maximum / 1-3 strings / 14-6 AWG Dimensions with Safety Switch (HxWxD) 17.7 x 14.6 x 6.8 / 450 x 370 x 174 21.3 x 14.6 x 7.3 / 540 x 370 x 185 In / mm Weight with Safety Switch 22 / 10 251 / 11.4 26.2 / 11.9 38.8 / 17.6 Ib / kc Noise < 25 <50 dBA Cooling Natural Convection Operating Temperature Range -40 to +140 / -40 to +601< F / "C Protection Rating NEMA 4X (Inverter with Safety Switch) " Revenue grade inverter P/N: SExxxxH-US0008NC4 Full power up to at least 50°C / 122'F: for power de -rating information refer to: https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf 'b SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 5/2019N01/ENG NAM. Subject to change without notice. RoHS Tukwila pitched roof IRONRIDGE 357 INDUSTRIAL BLVD., HAYWARD, CA 94545 Project Details Name Tukwila Dale 08/02/2019 Location Seattle, Seattle, WA, 98168 Total modules 25 Module O. Cells : Q.PEAK DUO L -G5.2 385 (35mm) Total watts 9,625 Dimensions 79.33" x 39.37 x 1.38" (2014.98mm x 1000.0mm x 35.0mm) Attachments 34 System Weight Load Assumptions Total system weight 1,464.6 lbs Wind exposure B WeighVattachment 43.1 lbs t Wind speed 110 mph Racking weight 169.1 lbs Ground snow load 20 psf Distributed weight 2.6 psf Attachment spacing 6.0' Root Information Roof material Comp Shingle Building height 20 4 Roof attachment None Roof slope 22 ° Attachment hardware Square Risk category 11 Span Details XR100 - Portrait Reaction Forces XR100 - Portrait Zone Max span Max cantilever Down Uplift Lateral Zone obs) (lbs) Ow 1 6' 2' 5" 1 393 161 116 6' 2'5" 2 393 334 116 3 6' 2'5" 3 393 528 116 Span Details XR100 - Landscape Reaction Forces XR100 - Landscape Zone Max span Max cantilever 1 8' 5" 3' 4" 2 8' 5" 3' 4" 3 8' 5" 3' 4" Zone 1 2 3 Down Uplift Lateral (Ibs) obs) obs) 201 82 59 201 171 59 201 270 59 Last updated by Dickson Harding on 08/02/19 01:18 PM Pane 1 of 5 Tukwila Roof Section 1 Definition 25 modules Portrait orientation Graphical entry Diagram Roof Section Weights Total weight: 1,464.6 lbs Weight/attachment: 43.1 lbs Total Area: 552.9 sq ft Distributed weight: 2.6 psf HMI HU 1111111 132' 5" IRONRIDGE 28357 INDUSTRIAL BLVD., HAYWARD, GA 94545 Roof Section (all segments) Provided rail: 202' [2 x 17', 12 x 14'] Attachments: 34 Splices: 4 Clamps: 60 Segments Cantilever Columns Length Cantilever Rail Attachments Splices Clamps Violations 4 13' 5" 8" None 28' [2 x 14'] 6 0 10 Row segment totals (x 2) -• 56' [4 x 14'] 12 0 20 5 16' 8" 2' 4" None 34' [2 x 17'] 6 0 12 6 20' 1None 56' [4 x 14'] 8 2 14 Row segment totals (x 2)-. 112' [8 x 14'] 16 4 28 Last updated by Dickson Harding on 08/02/19 01:18 PM Page 2 of 5 Tukwila Af% I RONRIDGE 357 INDUSTRIAL BLVD., HAYWARD, CA 94545 pitched roof Roof Section 2 Definition Roof Section Weights Roof Section (all segments) 0 modules Total weight: 0.0 lbs Provided rail: 0' D Landscape orientation Weight/attachment: 0.0 lbs Attachments: 0 Graphical entry Total Area: 0.0 sq ft Splices: 0 Distributed weight: 0.0 psf Clamps: 0 Diagram Segments Columns Splice Details TOP -FACING SLOT XR100 Length Cantilever INTERNAL SPLICE SIDE -FACING SLOT 265' 8" Cantilever Violations Rail Attachments Splices Clamps 00 • Splice Connection SELF -DRIVING SCREW - RAIL • INTERNAL SPLICE 1 t inriateri hv flir.knn Harrlinrs nn nRin9/1C1 ni .1R PM Pam.. nf Tukwila pitched roof Clamp Detail Mid Clamp, Plan Grounding Diagram PV MODULE FRAME UNIVERSAL FASTENING OBJECT Mid Clamp, Front UNIVERSAL FASTENING OBJECT PV MODULE FRAME RAIL End Clamp, Plan i IRONRIDGE 28357 INDUSTRIAL BLVD., HAYWARD, CA 94545 �- RAIL PV MODULE FRAME UNIVERSAL FASTENING OBJECT STOPPER SLEEVE End Clamp, Front ( (>) UF© Clamp -3 Fault Current Ground Path • Grounding Lug Min 10 AWG Copper Wire Bonded Splice (Rail Connection) Grounding Lugs and Wire are not required in systems using Enphase microinverters, STOPPER SLEEVE UNIVERSAL FASTENING OBJECT RAIL PV MODULE FRAME Last updated by Dickson Harding on 08/02/19 01:18 PM Page 4 of 5 LUSHOUMT DISCLAIMER RATINGS 2 MARKINGS 2 CHECKLIST 1. ATTACH BASES 2. PLACE RAILS 4 3. SECURE LUGS 4. SECURE MODULES CAMQ EXPANSION JOINTS ELECTRICAL DIAGRAM FLASHFOOT2 END CAPS 8 WIRE CLIPS 8 FLUSH STANDOFFS 8 MICROINVERTER KITS 9 SYSTEMS USING ENPHASE MICROINVERTERS OR SUNPOWER AC MODULES 9 SYSTEMS USING PHAZR MICROSTORAGE PRODUCTS 9 FRAMELESS MODULE KITS 10 MODULE COMPATIBILITY 10 MODULE COMPATIBILITY 11 MODULE COMPATIBILITY 12 This manual describes proper installation procedures and provides necessary standards required for product reliability. Warranty details are available on website. All installers must thoroughly read this manual and have a clear understanding of the installation procedures prior to installation. Failure to follow these guidelines may result in property damage, bodily injury or even death. IT IS THE INSTALLER'S RESPONSIBILITY TO: • Ensure safe installation of all electrical aspects of the array. All electrical installation and procedures should be conducted by a licensed and bonded electrician or solar contractor. Routine maintenance of a module or panel shall not involve breaking or disturbing the bonding path of the system, All work must comply with national, state and local installation procedures, product and safety standards. • Comply with all applicable local or national building and fire codes, including any that may supersede this manual. = Ensure all products are appropriate for the installation, environment, and array under the site's loading conditions. • Use only IronRidge parts or parts recommended by IronRidge; substituting parts may void any applicable warranty. - Review the Design Assistant and Certification Letters to confirm design specifications. Ensure provided information is accurate. Issues resulting from inaccurate information are the installer's responsibility. Ensure bare copper grounding wire does not contact aluminum and zinc -plated steel components, to prevent risk of galvanic corrosion. If loose components or loose fasteners are found during periodic inspection, re -tighten immediately. If corrosion is found, replace affected components immediately. = Provide an appropriate method of direct -to -earth grounding according to the latest edition of the National Electrical Code, including NEC 250: Grounding and Bonding, and NEC 690: Solar Photovoltaic Systems. • Disconnect AC power before servicing or removing modules, AC modules, microinverters and power optimizers. Review module manufacturer's documentation for compatibility and compliance with warranty terms and conditions. UL 2703 LISTED Gus #5003807 Intertek • Conforms to STD UL 2703 (2015) Standard for Safety First Edition: Mounting Systems, Mounting Devices, Clamping/ Retention Devices, and Ground Lugs for Use with Flat -Plate Photovoltaic Modules and Panels. • Max Overcurrent Protective Device (OCPD) Rating: 25A • Max Module Size: 24ft2 • Module Orientation: Portrait or Landscape • CAMO Specific Allowable Design Load Rating: 50 PSF downward, 50 PSF upward, 15 PSF lateral • System Level Allowable Design Load Rating: meets minimum requirements of the standard (10 PSF downward, 5 PSF upward, 5 PSF lateral). Actual system structural capacity is defined by PE stamped certification letters. CLASS A SYSTEM FIRE RATING PER UL 1703 • Any Roof Slope with Module Types 1, 2, and 3 • Any module -to -roof gap is permitted, with no perimeter guarding required. This rating is applicable with any third -party attachment. • Class A rated PV systems can be installed on Class A, B, and C roofs without affecting the roof fire rating. WATER SEAL RATINGS: UL 441 & TAS 100(A)-95 (FLASHFOOT2) • Tested and evaluated without sealant. • Any roofing manufacturer approved sealant is allowed. Ratings applicable for roof slopes between 2:12 and 12:12 STRUCTURAL CERTIFICATION • Designed and Certified for Compliance with the International Building Code & ASCE/SEI-7 Product markings are located on the 3/8" flange hex nut or Grounding Lug bolt head. .80 Marking can be on front or side of nut. PRE -INSTALLATION O Verify module compatibility. See Page 10 for info. TOOLS REQUIRED O Cordless Drill (non -impact) CI Impact Driver (for lag bolts) D Torque Wrench (0-250 in -lbs) El 5/16" Socket O 7/16" Socket El 1/2" Socket O String Line TORQUE VALUES • FlashFoot2 Lag Bolts (7/16" Socket): Fully seat D Bonded Splice Screws (5/16" Socket): 20 in -lbs O Grounding Lug Nuts (7/16" Socket): 80 in -lbs D Grounding Lug Terminal Screws (7/16 Socket): 20 in -lbs O Universal Fastening Object (7/16" Socket): 80 in -lbs D Expansion Joint Nuts (7/16" Socket): 80 in -lbs O Flush Standoffs (1/2" Socket): 140 in -lbs o Microinverter Kit Nuts (7/16" Socket): 80 in -lbs O Frameless Module Kit Nuts (7/16" Socket): 80 in -lbs EI 3/8" Bonding Hardware Kit Nuts (7/16" Socket): 250 in -lbs if using previous version of: FlashFoot, Integrated Grounding Mid Clamps, Grounding Lug, End Clamps, and Expansion Joints please refer to Alternate Components Addendum (Version 1.20). IRONRIDGE COMPONENTS XR Rail Bonded Splice UFO CAMO FlashFoot2 Expansion Joint End Cap Flush Standoff Microinverter Kit Frameless Module Kit Frameless End Clamp L -Foot Stopper Sleeve Grounding Lug Wire Clip 3/8" Bonding Hardware Kits Frameless Mid Clamp 0 2018 otcbt000m INC. VERSION too FLUSH MOUNT itastALuk, Install roof attachments. Mount Slotted L -Feet, FlashFoot2, or other compatible roof attachment per manufacturer's instructions. 9 IronRidge's all -In -one FlashFoot2 roof attachment is for pitched, composition shingle roofs. Refer to Page 8 or provided manual. Q Tested or evaluated third -party roof attachments: • Anchor Products - U -Anchor • S-5! Standing Seam Metal Roof Clamps - Certification of metal roof clamps includes bonding to both painted and galvalume metal roofs. Tighten clamp set screws to 130-150 in -lbs (>_ 24 gauge) or 160-180 in -lbs (22 gauge) roofs. Tighten S-5! M10 bolt to 240 in -lbs or S-5! Mini M8 bolt to 156 in -lbs. • EcoFasten Green Fasten GF -1 Anchors • QuickMount PV Roof Mounts and Tile Hooks - Tile Hook attaches to XR Rail using 3/8" Bonding Hardware Kit torqued to 250 in -lbs. • Quickscrews Solar Roof Hooks, Ejot Aluminum Roof Hooks, Unirac Creotecc Tile Hooks, or Solarhooks - Attach to XR Rails with L -Foot or 3/8" Bonding Hardware Kit torqued to 250 in -lbs. 9 Refer to Page 8 for installing Standoffs A. CONNECT SPLICES Use Bonded Splices, when needed, to join multiple sections of rail. Insert Bonded Splice 6" into first rail and secure with two self -drilling screws, spacing them approximately 1" apart and tightening to 20 in -lbs. Slide second rail over Bonded Splice and secure with two more self -drilling screws. 9 Rows exceeding 100 feet of rail must use Expansion Joints. 9 For XR10 and XR100 rails, insert screws along the provided lines. 9 Refer to Structural Certification letters for rail splice location requirements. Screws can be inserted on front or back of rails. B. PREPARE HARDWARE Slide square -headed bolts into side -facing rail slot. Space out bolts to match attachment spacing. Q Tape ends of rail, to keep bolts from sliding out while moving. 9 If using t -bolts, carry hardware onto roof and proceed. C. ATTACH RAILS Drop rail with hardware into roof attachment. Level rail at desired height, then torque to 250 in -lbs. �7 Rail can face either upslope or downslope on roof. Torque to 20 in -lbs I -1"-I 6" Inside Rail Preload and Space Square Bolts Insert T -bolt in top rail slot and torque hex nut to 80 in - lbs. Install a minimum 10 AWG solid copper or stranded grounding wire. Torque terminal screw to 20 in -lbs. Ground Lugs are only needed on one rail per continuous row of modules, regardless of row length (unless frameless modules are being used, see Page 9). If using Enphase microinverters or Sunpower AC modules, Grounding Lugs may not be needed, See Page 9 for more info. 9 Grounding Lugs can be installed anywhere along the rail and in either orientation shown. If installing lug underneath modules in areas with ground snow loads greater than 40 psf, place lug within 4 inches module frame edge. LIRE MC A. SECURE FIRST END Place first module in position on rails, a minimum of 1" from rail ends. Snap Stopper Sleeves onto UFO. Fasten module to rail using the UFO, ensuring that the UFO is hooked over the top of the module. Torque to 80 in -lbs. 9 Ensure rails are square before placing modules. Hold Stopper Sleeves on end while torquing to prevent rotation. 9 If using CAMO instead of UFO + Stopper Sleeve, refer to Page 6 for CAMO installation procedure. B. SECURE NEXT MODULES Place UFO into each rail, placing them flush against first module. Slide second module against UFO. Torque to 80 in -lbs. Repeat for each following module. S? When reinstalling UFO, move modules a minimum of 1/16" so UFOs are in contact with a new section of module frame. When UFOs are loosened and re -tightened, ensure UFO T -bolt bottoms out in rail channel before re -torquing UFO to achieve full engagement between T -bolt and rail. If using Wire Clips, refer to Page 8. C. SECURE LAST END Place last module in position on rails, a minimum of 1" from rail ends. Snap Stopper Sleeves onto UFO. Secure UFO Clamps on rails, ensuring they are hooked over top of module. Torque to 80 in -lbs. 9 Hold Stopper Sleeves on end while torquing to prevent rotation. 9 Repeat all steps for each following row of modules, leaving a minimum 3/8" gap between rows. '? If using CAMO instead of UFO + Stopper Sleeve, refer to Page6 for CAMO installation procedure. Use with one solid or stranded copper wire, conductor size 10-4AWG. IJ Terminal Screw (20 in -lbs) Hex Nut (80 in -lbs) 02018 IPONRIDGE, INC. VERSION 1.80 FLUSH MOUNTINSTALLATION MANUAL A. SLIDE INTO RAIL Slide CAMO into rail channel far enough to clear the module frame. CAMO requires 6" of clearance from end of rail. B. PLACE MODULE Place module on rails (module cells not shown for clarity). When installing CAMO the module can overhang the rail no more than 1/4". C. PULL TOWARDS END Pull CAMO towards rail ends, at 45 degree angle, so the bonding bolt contacts the module flange edge. D. SECURE TO FRAME Rotate handle with an upwards motion until CAMO snaps into rail channel. Ensure CAMO bonding pins are fully seated on top of module frame. FRAME COMPATIBILITY CAMO has been tested or evaluated with all modules listed in the Module Compatibility section having frames within the referenced dimensions. Be sure the specific module being used meets the dimension requirements. For installations with Hanwha Q CELLS modules with 32 mm frame heights, the maximum ground snow is 45 PSF (33 PSF module pressure). Module Gloss/Celts Frame Compatibility: X = I - 2.2 mm Y = 15 - 4f1 mm INC.• VERNNN11 18 2018 * FLUSH MOUNT INSTALLATION MANUAL -6 GROUNDING STRAP EXPANSION JOINT Grounding Strap Expansion Joints are required for thermal expansion of rows exceeding 100 feet of rail. Insert Internal Splice into first rail and secure with screw. Assemble and secure Grounding Strap 3/8" from rail end. Slide second rail over Internal Splice leaving 1" gap between rails. Attach other end of Grounding Strap with hardware, and torque hex nuts to 80 in -lbs. 9 Second Bonded Splice screw is not used with Expansion Joints. 9 Do not install module over top of expansion joint location. 6” Inside Rail ,Torque to IG" 80 in -lbs Fully Seat Screw 1" Gap Fault Current CAMO UFO or • Grounding Lug* -4 Ground Path Bonded Splice (Rail Connection) I Minimum 10 AWG Copper Wire• *Grounding Lugs and wire are not required in systems using certain Enphase microinverters or certain Sunpower modules. Equipment grounding is achieved with the Engage cable for Enphase or the AC module cable system for Sunpower via their integrated EGC. * 2018 IRONRIDGE, INC. VERSION 1.80 FLUSH MOUNT MN/411A11 Locate roof rafters and mark locations on roof. Drill 1/4" pilot holes and backfill with approved sealant. Slide flashing between 1st and 2nd course of shingles, ensuring flashing doesn't overhang the downhill shingle. Line up with pilot hole and insert supplied lag bolt with washer through flashing. Fully seat lag bolt. Place Cap onto flashing in desired orientation for ENV or N/S rails and rotate 180 degrees until it locks into place. V Rail can be installed on either side of FlashFoot2 Cap. End Caps add a completed look and keep debris and pests from collecting inside rail. Firmly press End Cap onto rail end. S2 End Caps come in sets of left and right. Check that the proper amount of each has been provided. Wire Clips offer a simple wire management solution. Firmly press Wire Clip into top rail slot. Run electrical wire through open clip. Snap closed once all wires have been placed. • • FLUSH STANDOFFS Attach Standoffs to roof locations with lag bolts (not included). Place flashing over Standoff. Attach L -Foot on Standoff washer with hardware. Torque to 140 in -lbs. Flashing Provided by Others . Torque to 140 in -lbs 02018 • VERSION 180 FLUSH MOUNT INSTALLATION MANUAL - Use IronRidge's Microinverter Kit to bond compatible microinverters and power optimizers to the racking system. Insert Microinverter Kit T -bolt into top rail slot. Place compatible microinverter or power optimizer into position and tighten hex nut to 80 in -lbs. If Installing in areas with ground snow loads greater than 40 psf, install MLPE devices directly next to module frame edge. COMPATIBLE PRODUCTS Enphase M250-72, 250-60, M215-60, C250-72, S230, S280, 10 6, IQ 6+, 10 7, IQ 7+, IQ 7X, Q Aggregator DREW MIG240, MIG300, G320, G640 Solar Edge P300, P320, P370, P400, P405, P505, P600, P700, P730, P800p, P800s, P850 AS USING ICR RSO IronRidge systems using approved Enphase products or SunPower modules eliminate the need for lay -in lugs and field installed equipment grounding conductors (EGC). This solution meets the requirements of UL 2703 for bonding and grounding and is included in this listing. The following Sunpower modules are included in this listing: Modules with model identifier Ab-xxx-YY and InvisiMount (G5) 46mm frame; where "A" is either E, or X; "b" can be 17, 18, 19, 20, 21, or 22; and "YY" can be C -AC, D -AC, BLK-C- AC, or BLK-D-AC. The following Enphase products are included in this listing: Microinverters M250-72, M250-60, M215-60, C250-72, and Engage cables ETXX-240, ETXX-208, ETXX-277. 9 A minimum of two inverters mounted to the same rail and connected to the same Engage cable are required. The microinverters or Sunpower AC modules must be used with a maximum 20 A branch rated overcurrent protection device (OCPD). 9 If an AC module is removed from a circuit for maintenance, you must first disconnect AC power and then install a temporary EGC to bridge the gap by inserting an AC extension cable (or via other NEC -compliant means), in order to maintain effective ground continuity to subsequent modules. SYSTEMS USING P1 R SOIICFIOSTORAGE PRODUCTS Bonding and grounding is achieved via the IronRidge system when using the Microinverter Kit. Running a separate equipment grounding conductor to the PHAZRs is not required. If installing in areas with ground snow loads greater than 40 psi and underneath a module, install PHAZR devices as close as possible to module frame edge. 02018 IFIOtN0OGE INC. VERSION 1.80 FLUSH NT INSTAL Insert Frameless Kit T -bolt in top rail slot. Place star washer over T -bolt, allowing it to rest on top of rail. Secure module clamps with a hex nut and torque to 80 in -lbs. 9 Tested or evaluated module clamps: • Sunforson silver or black SFS-UTMC-200(B) mid and SFS- UTEC-200(B) end clamps. • Sunpreme silver or black mid and end clamps with part numbers 7500105X where "X" is 1, 5, 6 or 7. • IronRidge silver or black mid and end clamps with part numbers FMLS-XC-001-Y where "X" is E or M and "Y" is B or blank. 9 Follow module manufacturer's installation instructions to install the module clamps. Q Frameless modules require using a Grounding Lug on every rail. 9 For Sunpreme Modules Only: If required to use slide prevention hardware, see Module Slide Prevention Addendum (Version 1.10). Module Clamp (80 in -lbs) Grounding Lugs Required on Every Rail , 1^ • ., '1 The Flush Mount System may be used to ground and/or mount a PV module complying with UL 1703 only when the specific module has been evaluated for grounding and/or mounting in compliance with the included instructions. Unless otherwise noted, "xxx" refers to the module power rating and both black and silver frames are included in the certification. MAKE- Amerisolar MODELS Modules with 35, 40 and 50mm frames and model identifier ASbYxxxZ; where 'b" can be 5 or 6; "r can be M, P, M27, P27, M30, or P30; and "Z" can be blank, W or WB. Astronergy Solar Modules with 35, 40, or 45mm frames and model identifier aaSM66 Pzz-xxx; where "aa" is CH or A; "yy" is either 10 or 12; and "zz" is blank or (BL). Frameless modules with model identifier CHSM6610P(DG)-xxx. Auxin Modules with 40mm frames and model identifier AXN6y6zAxxx; where "y" can be M or P; "z" can be 08, 09, 10, 11, or 12; and "A" can be F or T. Axitec Modules with 35 or 40mm frames and model identifier AC-xxxY/aa-ZZ; where "Y" is M or P; "aa" is 125 or 156; and "ZZ" is 54S, 60S or 72S. Boviet Modules with 40mm frames and model identifier BVM66aaYY-xxx; where "aa" can be 9, 10 or 12; and "YY" is M or P. BYD Modules with 35mm frames and model identifier BYDxxxAY-ZZ; where "A" can be M6, P6, or PH; "Y" can be C or K; and "ZZ" can be 30 or 36. Canadian Solar Modules with 35 and 40mm frames and model identifier CSbY-xxxZ; where "b" can be 1, 3 or 6; "Y" can be H, K, P, U, V, or X; and "Z" can be M, P, MS, PX , MSD, PAG, P -SD, MB -AG, PB -AG, MS -AG, or MS -SD. Frameless modules with model identifier CSbY-xxx-Z; where "b" can be 3 or 6; "Y" is K, P, U, or X; and "Z" can be M -FG, MS -FG, P -FG, MB -FG, or PB -FG. CertainTeed Modules with 35 and 40mm frames and model identifier CTxxxYZZ-AA; where "Y" can be M or P; "ZZ" can be 00,01, 10, or 11; and "AA" can be 01, 02 or 03. CSUN Modules with 35 and 40mm frames and model identifier YYxxx-zzAbb; where "YY" is CSUN or SST; "zz" is blank, 60, or 72; "A" is blank, P or M; and "bb" is blank, BB, BW, or ROOF. Ecosolargy Modules with 35, 40, and 50mm frames and model identifier ECOxxxYzzA-bbD; where "Y" can be A, H, S, or T; "zz" can be 125 or 156; "A" can be M or P; "bb" can be 60 or 72; and "D" can be blank or B. 02018 VERSION 1.80 FLUSH MOUNT INSTALLATION MANUAL ,110 ET Solar model ET-Y6ZZxxxAA; Modules 40,with 3�0'5�mmh�m�����d�r whe�"���LUrK8;�� im�Oor7�i�nd"AA'imWB, WW, BB, VVBG.VVVVG.VV8AC.VVBCO.VVVVCK].VVVVBCOcnQBAC. Rex Modules with 35.40.or50mmframes and model identifier FXS-xxxYv-ZZ; where "xxx" is the madule power rating; "VY is BB or BC; and 'ZZ'ioMAA1B.KxAA1N!K8AB1W, SAA1B, SAA1W, SAC1B, SAC1W, SAD1W, SBA1B, SBA1W, SBC1B, or SBC1W. GCL Modules with 35 and 40mm frames and and model identifier GCL-a6NY xxx; where "a" can be M or P; and "YY'`can baGO.72.or72H. GigaWatt Solar Modules with 4Omm frames and model identifier GWxxxYY; where "YY" is either PB or MB. Hanso| Modules with 35 and 4Omm frames and model identifier HSxxxYY-zz; where "YY" can be TB, TD, UB or UD; and "zz"can beAN1,AN3'AN4. Henwhg8o|ar h 40,Modules with 45,or50mmameeand model �enUfierHGLaaPG-YY-1-xxxZ;where "ua'ioehher0} or���"YY~iaPAurPB; and `Z"imblank orB. HanwhaC�CELLS Modules with 32.35.4O.and 42mmnframes and model identifier maY\-ZZ-nxx;where "aa"can be{J.or B.;"YY"can bePLUS, PRO, PEAK, LINE PRO, LINE PLUS, orPEAK DUO; and "ZZ"can baG3.G3.1. G4 [�4 1 L-G2,L-{S23 L-G3,L,G3.1, L-G3y, L -G4, L,G4.2, L-G4y, LG4.2/TAA, 8FR4G3, BLK-03, ' ' ' ' ' BFR-03.1.BLN'G3.1.BFR'04.BFF-{S4.1.BFR 04.3.BLK-{S41.G4/8C.G4]/SC.(341/TAA.04.1/ MAX, BFR B4.1/TXA.BFR G4.1/WAX.BLNG4.1/TAA.BLKG4.1/SC.EC'04.4.BS.BLK'G5.L-GG.2.nr L-G5.2/H. HeUene Modules with 4Omm frames and model identifier YYZZxxx; where "YY" is 36.GD.72'or0G;and 'ZZ'is M, P, or MBLK. Hyundai Modules with 35, 40 and 50mm frames and model identifier HiS-YxxxZZ; where "Y" can be M or S; and "ZZ" can be MI, MF, MG, SG, RI, RG(BF), RG(BK), Ti or TG. |Vek Modules with 40 or 5Omm frames and model identifier IT-xxx-YY; where "YY" is blank, HE, or SE, or SE72, JA Solar Modules with 35, 40 and 45mm frames and model identifierJAyyzz-bb-xux/aa; where "yy" can be M, P, K4GorP6;^zz"can be blank, (K), (L), (R), (V), (BK), (FA), (TG), (FA)(R), (L)(BK), (L)(TG), (R)(BK), (R) (TG).(V)(BK),(S%)(TG).or(L)(BN)(T8);^bb^can be48.GO.7J.GOSO1or72SO1|and ^aa^can baMP, SI, SC, PR, RE, 3BB.4BB.4BB/R[, 588. Jinko Modules with 35 and 4ornm frames and model identifier JKMYxxxZZ-aa; where "Y' can either be blank orS;"ZZ"can boP,PP, YW; and ''aa''can boblank, GQ,60B.GOH.GD' 4.60B-J4.60B'Ep60(P|us).60-< 60-M%, 72, 72-V, 72H -V, 72L -V, 72 -MX. Frameless modules with model identifier JKMxxxPP-DV. Kyocera Modules with 46mm frames and model identifier KYxxxZZ-AA; where "Y" is DorU;^ZZ"isblank, GX, or SX; and "AA" is LPU, LFU, UPU, LPS, LPB, LFB, UFB8, LFB2, LPB2, 3AC, 3BC, 3FC, 4AC, 4BC, 4FC, 4DC, 5AC, 5BC, GFC, 5UC, 6BC, 6FC, 8BC, 6MCA, or 6MPA. LG Modules with 35,40,and 46mm frames and model identifier LGxxxYaZ-bb; where "Y" is A, E, N. K]' S; "s�is1or����ksG.K~T,ormCand"bh"ioA8'A5.B8.03'G4'cvM4. Longi Modules with 4Ommframes and model identifier �RG-YYZZ'xxxKA; where "Y\Y" can beGUor72; and "ZZ" can be BK, BP, HV, PB, PE, or PH. Mission Solar Modules with 4Omm frames and model identifier MSExxxZZaa; where "ZZ" can be MM, SE, 8OorSQ; and "aa"can be1J.4J.4S.5K.STGJ.GS.orGVK Mitsubishi Modules with 46mm frames and model identifier PV-MYYxxxZZ; where "YY" is LE or JE; and " "in either HD, HD2^orFB. Motech \K8and XSseries modules with 4O.45.orSOnnmframes. Neo Solar Power Modules with 35mm frames and model identifier D6YxxxZZaa; where "Y" can be M orP;'ZZ''can be B3A, B4A, E3A, E4A, H3A, H4A; and "aa" can be blank, (TF), ME or ME (TF). Panasonic Modules with 35 and 40mm frames and model identifier VBHNxxxYYzzA; where "YY" can be either SA orKA; 'zz^can boeither 81,82'O3.O4.OG.O88.11.11B'1G.1SB.18.18B,17.or18;and ''A"can be blank, E or G. Peimar Modules with 40mm frames and model identifier SGxxxYzz; where "Y" can be M or P; and "zz" can be blank, (BF), or (FB). VER -_--____-- INC -.-___ FLUSH MOUNT INSTALLATION MANUAL - f� 1d W R�3�ai Phono Solar Modules with 35, 40, or 45mm frames and model identifier PSxxxY ZZ/A; where "Y" is M or P; "ZZ" is 20 or 24; and "A" is F, T or U. Prism Solar Frameless modules with model identifier BiYY-xxxBSTC; where "YY" can be 48, 60, 60S, 72 or 72S. REC Solar Modules with 30, 38 and 45mm frames and model identifier RECxxxYYZZ; where "YY" is M, PE, TP, or TP2S; and "ZZ" is blank, BLK, SLV, or 72. Renesola Modules with 35, 40 or 50mm frames and model identifier JCxxxY ZZ; where "Y" is F, M or S; and "ZZ"is Ab, Ab-b, Abh, Abh-b, Abv, Abv-b, Bb, Bb-b, Bbh, Bbh-b, Bbv, Bbv-b, Db, or Db-b. Renogy Modules with 40 or 50mm frames and model identifier RNG-xxxY; where "Y" is D or P. S-Energy Modules with 40mm frames and model identifier SNxxxY-ZZ; where "Y" is M or P; and "ZZ" is 10, or 15. Seraphim Energy Group Modules with 40mm frames and model identifier SEG-6YY-xxxZZ; where "YY" can be MA, MB, PA, PB; and "ZZ" can be BB, WB, or WW. Seraphim USA Modules with 40 and 50mm frames and model identifier SRP-xxx-6YY; where "YY" can be MA, MB, PA, PB, QA-XX-XX, and QB-XX-XX. Sharp Modules with 35 or 40mm frames and model identifier NUYYxxx; where "YY" is SA or SC. Silfab Modules with 38mm frames and model identifier SYY Z-xxx; where "YY" is SA or LA; SG or LG; and "Z" is M, P, or X. Solaria Modules with 40mm frames and model identifier PowerXT xxxY ZZ; where "Y" can be R or C; and "ZZ" can be AC, BD, BX, BY, PD, PX, PZ, WX or WZ. SolarTech Modules with 42mm frames and model identifier STU-xxxYY; where "YY" can be PERC or HJT. SolarWorld Sunmodule Plus, Protect, XL, Bisun, Bisun XL, may be followed by mono, poly or duo and/or black or bk; modules with 31, 33 or 46mm frames and model identifier SW-xxx. Stion Thin film modules with 35mm frames and model identifier STO-xxx or STO-xxxA. Thin film frameless modules with model identifier STL-xxx or STL-xxxA. SunEdison Modules with 35, 40, or 50mm frames and model identifier SE-YxxxZABCDE; where "Y" is B, F, H, P, R, or Z; "Z" is 0 or 4; "A" is B, C, D, E, 1-1, 1, J, K, L, M, or N; "B" is B or W; "C" is A or C; "D" is 3, 7, 8, or 9; and "E" is 0, 1 or 2. Suniva Modules with 35, 38, 40, 46, or 50mm frames and model identifiers OPTxxx-AA-B-YYY-Z or MVXxxx-AA-B-YYY Z; where "AA" is either 60 or 72; "B" is either 4 or 5; "YYY" is either 100,101,700,1B0, or 1B1; and "Z" is blank or B. Sunpower Modules with model identifier Ab-xxx-YY and standard (G3) or InvisiMount (G5) 46mm frame; where "A" is either E, P or X; "b" can be 17, 18, 19, 20, 21, or 22; and "YY" can be blank, NE, BLK, COM, C-AC, D-AC, BLK-C-AC, or BLK-D-AC. Sunpreme Frameless modules with model identifier GXB-xxxYY; where "YY" is blank or SL. Sunspark Modules with 40mm frames and model identifier SYY-xxZ; where "YY" can be MX or ST; and "Z" can be P or W. Suntech Vd, Vem, Wdb, Wde, and Wd series modules with 35, 40, or 50mm frames. Talesun Modules with 35 and 40mm frames and model identifier TP6yyZxxx-A; where "yy" can be 60, 72, H60 or H72; "Z" can be M, or P; and "A" can be blank, B, or T. Trina Modules with 35, 40 or 46mm frames and model identifier TSM-xxxYYZZ; where "YY" is PA05, PC05, PD05, PA14, PC14, PD14, PE14, or DD05; and "ZZ" is blank, A, A.05, A.08, A.10, A.18, .05, .08, .10, .18, .08D, .18D, 0.82, A.082(II), .002, .00S, 05S, 08S, A(Il), A.08(II), A.05(II), A.10(II), or A.18(II). Frameless modules with model identifier TSM-xxxYY; and "YY" is either PEG5, PEG5.07, PEG14, DEG5(II), DEG5.07(II), or DEG14(II). Winaico Modules with 35 or 40mm frames and model identifier Wsy-xxxz6; where "y" is either P or T; and z is either M or P. Yingli Panda, YGE, and YGE-U series modules with 35, 40, or 50 mm frames. PLA1N-Igif OP'( SLIP PERMIT NUMBER: EL19-0673 PROJECT NAME: STEPHAN HEED - SOLAR SITE ADDRESS: 13608 34TH AVE S X Original Plan Submittal Response to Correction Letter # DATE: 08/21/19 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Building Division Public Works Fire Prevention El Structural Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) REVIEWER'S INITIALS: DATE: 08/22/19 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved 111 Corrections Required (corrections entered in Reviews) DUE DATE: 09/19/2019 Approved with Conditions E] Denied (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 1J Fire 13 Ping ID PW LJ Staff Initials: 12/18/2013 S M E INC OF SEATTLE Horne Ilspafiol Contact Safety & Health Claims & Insurance 43 Washington State Department of Labor & Industries Search L&I Page 1 of 2 MEM A -Z Index Help My Workplace Rights Trades & Licensing S M E INC OF SEATTLE Owner or tradesperson Principals MARVICH, STEPHEN E PINSKY, ADAM A BAKER, JON T, AGENT Doing business as S M E INC OF SEATTLE WA UBI No. 601 524 252 828 POPLAR PL $ SEATTLE, WA 98144 206-329-2040 KING County Business type Corporation Goveming persons STEPHEN E MARV1CH ADAM A PINSKY; JOHN P VVITTMAN; JON T BAKER; Certifications & Endorsements OMWBE Certifications No active certifications exist for this business. Apprentice Training Agent Registered training agent. Check their eligible programs and occupations. License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor License specialties GENERAL License no. SMEINS*066DB Effective — expiration 03/02/1994— 03/02/2020 Designated administrator BAKER, JON T Active. Meets current requirements. Active. Meets current requirements. License type License no. Master Electrician BAKERJT973LR Bond CBIC Bond account no. 636702 $4,000.00 Effective date Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601524252&LIC=SMEINS*066DB&SAW= 8/28/2019