Loading...
HomeMy WebLinkAboutPermit D18-0374 - ARCO STATION AM/PM - AIR CURTAIN AND DELI CASEARCO STATION- AM/PM 15252 TUKWILA INTL BLVD D18-0374 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 0043000070 15252 TUKWILA INTL BLVD Project Name: ARCO STATION - AM/PM Permit Number: D18-0374 Issue Date: 12/17/2018 Permit Expires On: 6/15/2019 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: HARBOR OLYMPIC LAND LLC 1440 PUYALLUP AVE , TACOMA, WA, 98421 MICHAEL BARTHOL 1940140 AVE W - SUITE 200 , LYNNWOOD, WA, 98036 SUMMIT PROPERTIES & DEV CO INC 6445 CITATION DR - SUITE G , CLARKSTON, MI, 48346 SUMMIPD834KP WEST COAST PETROLEUM SERVICE INC 5800 SOUTHCENTER BLVD , TUKWILA, WA, 98188 Phone: (425) 954-8768 Phone: (248) 625-4711 Expiration Date: DESCRIPTION OF WORK: INSTALL AIR CURTAIN OVER FRONT DOOR AND SET A DELI CASE IN THE STORE (GRAB AND GO) Project Valuation: $7,000.00 Type of Fire Protection: Sprinklers: NO Fire Alarm: NO Type of Construction: VB Electrical Service Provided by: TUKWILA Fees Collected: $432.05 Occupancy per IBC: B Water District: 125 Sewer District: VALLEY VIEW Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 Permit Center Authorized Signature: Date: ��� 7'4( I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulati ruction or the performance of work. I am authorized to sign and obtain this development per a d .:gre he conditions attached to this permit. Signature: Print Name: 61—Lit .ems w , Date: (1, in is This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** Q. CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov ' Building Permit No.T121v Project No. Date Application Accepted: f3/, t Date Application Expires: (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 15252 Tukwila International Blvd. Tenant Name: BP Arco AMPM #82941 King Co Assessor's Tax No.: 0043000070 Suite Number: Floor: New Tenant: ❑ Yes ® .. No PROPERTY OWNER Name: West Coast Petroluem Services Inc. Address: 5800 Southcentr Blvd City: Tukwila State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: Michael Barthol, AIA Address: 19401 40th Avenue West, Ste 200 City: Lynnwood State: WA zip: 98036 Phone: (425) 954-8768 Fax: Email: mbarthol@pmdginc.com GENERAL CONTRACTOR INFORMATION Company Name: Summit Properties Address: (,4#/I`r,od/.bCity: J V tate:�'Jtlf� Zitte.34� `� Phone:( Fax: No.: Exp Date: t , Il9 t Tukwila Business License No.: ARCHITECT OF RECORD Company Name: Architect Name: Address: City: State: Zip: Phone: Fax: Email: ENGINEER OF RECORD Company Name: Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: West Coast Petroleum Services, Inc Address: 5800 Southcenter Blvd. City: Tukwila State: WA Zip: 98188 BUILDING PERMIT INFORMATION — 206-431-3670 Valuation of Project (contractor's; bid price): $ 1 000 Existing Building Valuation: $ Describe the scope of work (please provide detailed information): N Sfitt — A, (. 6.22:^n , ..r 0J-02 N CG se n$ id-r.1 �1a Will there be new rack storage? ❑ Yes yCNo If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1" Floor 2"d Floor 3rd Floor Floors thin Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes VI No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. 0 PUBLIC WORKS PERMIT INFORMATION — 206-433-0179 Scope of Work (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ ...Tukwila ❑ ... Water District #125 ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila ❑ ...Sewer Use Certificate ❑ .. Highline ❑ ...Valley View ❑ .. Renton ❑ ...Sewer Availability Provided ❑ .. Renton ❑ .. Seattle Septic System: ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34") ❑ ...Technical Information Report (Storm Drainage) 0 ...Bond ❑ .. Insurance 0 .. Easement(s) Proposed Activities (mark boxes that apply): ❑ ...Right-of-way Use - Nonprofit for less than 72 hours 0 ...Right-of-way Use - No Disturbance 0 ...Construction/Excavation/Fill - Right-of-way ❑ Non Right-of-way ❑ ...Total Cut ❑ ...Total Fill cubic yards cubic yards O ...Sanitary Side Sewer O ...Cap or Remove Utilities 0 ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ .. Geotechnical Report ❑ .. Maintenance Agreement(s) 0 ... Traffic Impact Analysis ❑ ...Hold Harmless — (SAO) ❑ ... Hold Harmless — (ROW) ❑ .. Right-of-way Use - Profit for less than 72 hours ❑ .. Right-of-way Use — Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑ .. Abandon Septic Tank ❑ .. Curb Cut 0 .. Pavement Cut ❑ .. Looped Fire Line 0 ...Permanent Water Meter Size... ❑ ...Temporary Water Meter Size .. ❑ ...Water Only Meter Size ❑ ...Sewer Main Extension Public O ...Water Main Extension Public WO # WO # WO # Private 0 Private ❑ ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding 0 ...Deduct Water Meter Size 33 FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ ...Water ❑ ...Sewer Monthly Service Billing to: Name: ❑ ...Sewage Treatment Day Telephone: Mailing Address: City State Zip Water Meter RefundMilling: Name: Day Telephone: Mailing Address: City State Zip PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OFJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING b R"OR A GRIZ D Signature: �'� Date: 11/28/2018 Print Name: Michael Barthol, AIA Mailing Address: 19401 40th Avenue West, Ste 200 Day Telephone: (425) 954-8768 Lynnwood WA 98036 City State Zip Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK $864.10 D18-0374 Address: 15252 TUKWILA INTL BLVD Apn: 0043000070 $432.05 Credit Card Fee $12.58 Credit Card Fee R000.369.908.00.00 0.00 $12.58 DEVELOPMENT $407.87 PERMIT FEE R000.322.100.00.00 0.00 $232.04 PLAN CHECK FEE R000.345.830.00.00 0.00 $150.83 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $25.00 TECHNOLOGY FEE $11.60 TECHNOLOGY FEE R000.322.900.04.00 0.00 $11.60 D18-0375 Address: 5800 SOUTHCENTER BLVD Apn: 1157200352 $432.05 Credit Card Fee $12.58 Credit Card Fee R000.369.908.00.00 0.00 $12.58 DEVELOPMENT $407.87 PERMIT FEE R000.322.100.00.00 0.00 $232.04 PLAN CHECK FEE R000.345.830.00.00 0.00 $150.83 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $25.00 TECHNOLOGY FEE $11.60 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R15924 R000.322.900.04.00 0.00 $11.60 1 $864.10 Date Paid: Wednesday, November 28, 2018 Paid By: CHARLES WITHEY Pay Method: CREDIT CARD 618295 CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA 0017340000802374464500 Date: 11/28/2018 02:59:20 PM CREDIT CARD SALE VISA CARD NUMBER: **********6451 K TRAN AMOUNT: $864.10 APPROVAL CD: 618295 RECORD #: 000 CLERK ID: Rachelle {CARDHOLDER'S SIGNATURE} I AGREE TO PAY THE ABOVE TOTAL AMOUNT ACCORDING TO THE CARD ISSUER AGREEMENT (MERCHANT AGREEMENT IF CREDIT VOUCHER) Thank you! Merchant Copy CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA Date: 11/28/2018 02:59:20 PM CREDIT CARD SALE VISA CARD NUMBER: **********6451 K TRAN AMOUNT: $864.10 APPROVAL CD: 618295 RECORD #: 000 CLERK ID: Rachelle Thank you! Customer Copy INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: //eCO /iv P Type of Inspection: ,JG'/ /e./L Address: ./S2i2_ ls7,41 i-- ini-ak.e4-74 Date Called: 1 9r . 8Ldo Special Instructions: �/ 04-6/ 4 /4.5 .7ER01/1 Date Wanted: /2 -/9- e a.m. p.m. Requester: G/<6e. . Phone No: 13,4 5-1044 615Z1.=. ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: t/!/-S3,,4 < Inspector: f f-1 REINSPECTIDN FEE REQUIRED_ Prinr to nex Date: 261 _ t insnectinn. fe must be Oasis® Product Specifications ITEM NO: PROJECT: DATE: Refrigerated Self -Service End Cap MODEL SHOWN: FSE45R Cnmomu to ItSI 810 7 TYPE II Length% include end panels a FSE45R 37"L x 51-112"0 x 61-1/2"H STANDARD FEATURES ■ Breeze'E (Type -II) w/ EnergyWise s/c refrigeration II 1" bumper, double strip (specify color) ■ Compressor air intake in one side & out other side. All louvered panels cannot be blocked a Full end panel w/rnirror interior • Integrated average product temperature of 40°F or less a LED top light(s) • One year parts & labor; 5 year compressor warranty a Price tag moulding (matches interior color) a Removable deck pans provide complete access to evaporator coil & refrigeration connections • Shelving removable and adjustable on 1" centers Features EXTERIOR COLOR Standard a aminated non -premium) Con Irm pattern/grain direction Options' ❑ animated premium) Confirm pattem/grain direction ❑ Stainless steel (includes lower front panel) INTERIOR COLOR o Black ❑ Stainless steel LOWER FRONT PANEL COLOR ❑ Black o Stainless steel (w/stainless ext. only) BASE o Casters w/ levelers (n/a w/ remote ref.) n Levelers (only) SHELVING o Metal shelves (3), non -lighted o Metal shelves (2), lighted (LED) o Metal shelves (2), non -lighted o Metal shelves (3), lighted (LED) ELECTRICAL CONNECT o 6' straight blade power cord (self-cont.) o 6' locking power cord (self-cont.) o Electrical leads (remote) REFRIGERATION o Breeze—E (Type -II) w/ EnergyWise s/c refrigeration o Note: Remote doesn't inc Conds unit. Floor drain regd. o Remote w/thermostat, solenoid & TXV MISCELLANEOUS o Clean Sweep® coil cleaner (n/a w/remote) o Second year parts & labor warranty (excludes compressor) REVIEWWD t-OR CODE COMPLIANCE APPROVED DEC 052 3 City BUILDING°Tukwila DIVISION Dl 8- O37y Structural Concepts 888 E. Porter Rd. Muskegon, MI 49441 Ph. 231-798-8888 Fx. 231.798-4960 www.structuralconcepts.com RECEIVED CITY OF TUKWILA NOV 2 8 2018 PERMIT CENTER Note: Information is subject to change at any time. Visit www.structuralconcepts.com for the most current specs. Revised 2/28/2017 20032220 Oasis® Product Specifications intended Environment: Type II - Designed to operate in ambient conditions of 80°F and 60% relative humidity unless noted otherwise in system information below. Zone All Intended Product To Be Displayed Packaged refrigerated products PLAN VIEW r1EG li:t:..AL JL':::. r/i 1 ]tVAKL::o TH C. _EA030.: i'O'M6A A:o:i:i; LO:ATVM OF.M141N 1.1Clt UP, "fOA #2 01 E REF. IU W-Y:51IJ iU! %1ll1 C3 i'.' rvc a. �W to 01tu le N 0 r© m v 31 1/2' TOE r KICK — 37' STANDARD THREE SHELVES SHOWN :1uTE: ALL fiiMENfSION:i=2L:i1,'; Ci J.t.'41i4J14,t..1 LIRE+ i:'J:::.:i. '.1. ®-AL4CY;! iLJUrc Y'1ii? a;td,Tl�s .AC ',ZA S AltEp. vity Warmest Avg Prod Temp ° F 40 SIDE VIEW S../o i itd 7 �ti_ 31 1/2' TOE K ICK 37' OPTIONAL TWO SHELVES SHOWN '.V.t:c.l tA Model Technical Specifications Model L" L1" L2" System Circuit Volts Phs Freq Amps Watts Wires NEMA Plug SST BTUH Wt FSE4SR N/A 37.011 .00 Remote(Type II) Circuit 81 110.120' 1 60 2.58' 101 2+G Leads Multiple 20.00 7675 850 SeU.Contained Circuit al 206.240 1 60 15.84 2.845 2+G 6.20P or L6.20P N/A N/A oes not include electric defrost on freezer models. Regulatory Approvals: All Models Accordance with AHRI Std 1200 ETL Listed to UL 471 ETL Listed to CAN/CSA 22.2 No. 120 ETL Sanitation to NSF 7 to Acoerdsticexiix �4HSi�tStd'.�21 Ao& Structural D01 2017 Snaggy lirmcI.nty c•nn!!•m Important Notes: 1) EL FCTRICAt NOTF. II GFCI is required, a GFCI breaker MI IST he used in lieu of a GFCI receptacle 2) 37• minimum door entry clearance required (without shipping skid). 3} Units are supplied with levelers. They must be adjusted during installation to ensure the unit is level end plumb. Dimensions reflect levelers extended 1 V4'. 4) Performance issues (p nduc) temperatures, water on floor, etc ) caused by adverse conditions are not covered by warranty. 5) Keep unit at least 15' from exterior doors, overhead HVAC vents, or any air curtain disruption. 6) End panels must be tightly joined or kept at feast 6" away from any structure to prevent condensation. 7) Do not expose unit to direct sunlight or any heat source (ovens, fryers, etc.), B88 E. Porter Rd Muskegon, MI 49441 Ph. 231-790.8808 RECEIVED CITY OF TUKWILA 4AR%21 2018 ?ERiV IY CENTER Note: Information is subject to change at any time. Visit www.structuralconcepts.com for the most current specs. LCA-2 (w/Scholle '1910 3/16", Long Feed) Serv:.rr., and airpot<s soul :,apzirately Specifications • Accommodates 12ga1(1.9L) and most lgal (3.8L) bag -in -box (BIB) containers • Attractive appearance and narrow 12" (30.5 cm) width • FlavorGard® technology continuously monitors extract -to -water ratio and assures flavor consistency • Refill or rinse LED lights alert the operator for concentrate or cleaning • Ventilated Cabinet • Insulated product cabinet assures maximum product life Agency: SH° Product #: 34400.0031 Finish: Black Faucet: Lower Connector: Scholle 1910LX Legs: 4" Black Legs Electrical & Capacity Cord Attached Volts Amps Watts Product Ratio: 25:1-60:1 Water Access: Plumbed Plug Type 120 14.2 1700 Yes NEMA 5-15P Plumbin PSI Requirements kPa 20-90 138-621 VBUNN' Fitting Supplied 3/8" Male Flare Fitting 8oz cups/hr 236m1 cups/hr Input H'b Temp. 810 60°F (15.5°C) REVIEWED I -OR CODE COMPLIANCE APPROVED DEC 05 2318 City of Tukwila BUILDING DIVISION YCL LISTED Additional Features Hot Water Button Alt Disp Rate 2.5 oz/s(74m1/s) Water Flow Required (GPM) Phase L it Wires plus Ground 2 CAD Drawings 20 • Hertz 60 BUNK® reserves the right to change specifications and product design without notice. Such revisions do no, ,:IcNOV Z "u 2018 the buyer to corresponding changes, improvements, additions or replacements for previously purchased equipment. 02/2812015 PIIIERIVRAtiftlYAR For most current specifications and other Info visit bunn.com. LCA-2 with portion control. English Metric II II II II Unit Width 12.2 in. 15.6 (Door Open) I-- 12.16 Height 31.3 in. Depth 24.8 in. 31.0 cm 79.5 cm 63.0 cm - 1. 31.06 (Door Open) --- 10.19 krist Width 8- a=o o=o6 V= =0 =V U=0 V= 0= =:* 29 98 = =6c Water Supply Connection 13.37 -I 24.83 Height • 31 33 Power Supply Connection 1.61 — 11.99 (Cabinet) 1-t— 8.77 Shipping Depth [ Weight 90.210 lbs Volume 40.919 kgs GPIBUNN. BUNN® reserves the right to change specifications and product design without notice. Such revisions do not entitle Croated the buyer to corresponding changes, improvements, additions or replacements previously purchased equipment. fl22612016 V 15 Series ice and water dispenser with Chewblet° ice machine agion ANTIMICROBIAL PRODUCT PROTECTION NOTE: For use in applications with greater than 5 mg/I but Tess than 400 mg/I total dissolved solids in water and less than 200 mg/I hardness (either naturally occurring or treated with reverse osmosis or other TDS reducing technology). Not recommended for use with softened water. 115 V 60 Hz — Ice and water dispensers Ice storage capacity Configuration Filter* Item number 15 Ib (6.8 kg) countertop ice and water no filter 15CI100A-IW-NF-ST 00 internal 15C1100A-IW-CF-ST-00 freestanding ice and water no filter 15FS100A-IW-NF-ST 00 internal 15FS100A-IW-CF-ST-00 countertop ice -only no filter 15C1100A-NW-NF-ST 00t internal 15CI100A-NW-CF-ST 00t freestanding ice -only no filter 15FS100A-NW-NF-ST-00t internal 15FS100A-NW-CF-ST 00t t ENERGY STAR certified * Internal filter is a 5 micron particle and carbon filter Job Item countertop and freestanding Features Compact footprint, only 14.62" (37.1 cm) W x 23.50" (59.7 cm) D 15 Ib (6.8 kg) ice storage capacity Integral air-cooled ice machine with up to 125 Ib (56.7 kg) daily production of popular Chewblet ice - designed to serve up to 50 people (160 servings per 10 hr days) - soft, chewable, compressed nugget ice is preferred over cubes' - environmentally responsible R134a refrigerant with zero ozone depletion potential - energy saving sleep mode - quiet production without noisy harvest cycles - meets the Consortium for Energy Efficiency (CEE) Tier 2 specifications for highly efficient ice machines - ice -only models now ENERGY STAR° certified Durable, attractive dispenser - modern styling, stainless steel exterior with accent trim - dispense -activated soft blue light illuminates point -of -use - easy -to -clean, removable 20 oz (591 ml) drip tray - dispenser top can support 35 Ib (15.9 kg) Designed with sanitation in mind -Aglow' silver -based antimicrobial product protection of key ice and water contact components3 -capacitive touch display eliminates direct user contact with ice - accommodates cups up to 8.80" (22.4 cm) tall Installation - comes fully assembled -two easy connections — electric and water -drainless design allows dispenser to be placed anywhere a water line can be run and eliminates the cost of a drain installation Warranty -2 years parts and labor, 5 years compressor parts - optional extended third year warranty (item# 00960732) Accessories Base stand for converting countertop models (item# 00956292) 4.00" (10.16 cm) leg kit for CI - countertop models (item# 00956300) 6.00" (15.24 cm) leg kit for FS - freestanding models (item# 00956318) Drip tray drain kit for countertop models (includes 4.00" (10.16 cm) legs) (item# 00981977) Drip tray drain kit for freestanding models (item# 00956375) SafeCLEAN Plusrm 15 series single use kit (item# 01054691) SafeCLEAN Plus case of 24 packs (item# 01050863) Cartridge, replacement 5 micron particle/carbon (item# 00968107) For additional water treatment and other accessories referto form# 4025 801 Church Lane I Easton, PA 18040, USA 1.800.523.9361 11.610.252.7301 I follettice.com ArOLLEIT° Innovative solutions, inspired by ice 10% TOM 1.0,01r0 nen. I Paper certi"edhy. au eosrcmnuace nea I The Forest Stewardship Council (FSC) and the Sustainable Forestry Initiative (SFI) r Specification Ice storage capacity W1 Width D1 Depth of bottom D2 Depth of top H1 Height — countertop models H2 Height —freestanding models H3 Height, base stand H4 Dispense height clearance Ventilation clearance Service clearance C1 115 V/60/1 electrical C2 Water inlet Air temperature Water temperature Water pressure Ice production at 70 F (21 C) air and 50 F (10 C) water Ice production at 90 F (32 C) air and 70 F (21 C) water Energy consumption 90 F (32 C) air and 70 F (21 C) water Heat rejection Water consumption Approximate shipping weight — countertop models Approximate shipping weight — freestanding models NOTE: For indoor use only. Designed to provide in-house services for resid 15ib(6.8kg) 14.62" (37.1 cm) 22.12" (56.2 cm) 23.50" (59.7 cm) 22.50" (57.2 cm) 47.00" (119.4 cm) 24.50" (62.2 cm) 8.80" (22.40 cm) 3.00" (7.62 cm) on each side 3.00" (7.62 cm) behind and on each side 5 amps. Connect to dedicated 15 amp circuit, fuse or breaker. 8' (2.4 m) cord w/ NEMA 5-15 90° plug. 1/4"MPT 50-100F(10-38C) 40-90F(4-32C) 10 - 70 psi (69 - 482 kpa) 125 Ib (56.7 kg) 100 Ib (45.4 kg) 6.9 kWh per 100 Ib (45.4 kg) ice 1700 BTU/hr 12 gal (45.4 L) of potable water per 100 Ib (45.4 kg) of ice 100 Ib (46 kg) 130 Ib (59 kg) for commercial use. Follett is not able ential installations. SHORT FORM SPECIFICATION: (Choose one) _ Ice and water or ice -only dispenser to be Follett° automatic load in (choose one) _ countertop or _freestanding configuration, with 15 Ib (6.8 kg) of storage. Environmentally responsible R134a ice machine to be air-cooled. Ice machine to produce approximately 125 Ib (56.7 kg) of Chewblet compressed nugget ice at air temperature of 70 F (21 C) and water temperature of 50 F (10 C). ice machine to be equipped with printed circuit board and diagnostics to allow simplified servicing and with capacitive touch user interface. Storage area insulated with non-CFC, high density foam -in -place polyurethane. 8' (2.4 m) cord and NEMA 5-15 90° plug provided 115 V/60/1. NSF and ETL listed. For use in applications with greater than 5 mg/I but less than 400 mg/I total dissolved solids in water and less than 200 mg/I hardness (either naturally occurring or treated with reverse osmosis or other TDS reducing technology). 15 Series countertop and freestanding Form N5020 07/15 O Follett Corporation Dimensional drawing W1 H4 111, air } intake H1 H2 H3 D1 i 15 62" (39.7 cm) 00000 00000 00000 0000000 0000000 0000000 0000000 0000000 0 o 0 0 0 0 0 0000000 0000 0000 000o0 00000 000o0 00000 c 2 i 15.69" (39.8 cm) 0 0 2.40" (6.10 cm)_H 2.98" (7.57 cm) 1 1607(473mgcups, 2/3full ofice. 2 Independent third party studies. Contact Follett for details. 3 Dlsclalmer:Antimicrobialprotectionislimitedtothetreatedcomponentsanddoesnottreatwater 0r ice. 4 ENERGY STAR certification applies only to ke-only dispensers. While the Symphony Plus Ice and water dispensers have the sarne efficient Ice makers and refrigeration systems with the same Ice machine electrical andwater consumption as their complementary Ice -only models, there is no ENERGY STAR category for ice and water dispensers at this time. Agion is a registered trademark of Sciessent LIC. ENERGY STAR and the ENERGY STAR mark are registered US marks. SefeUEAN Plus is a trademark of the Foflelt Corporation. Chewblet and Follett are registered trademarks of Follett Corporafion. registered In the US. Follett reserves the right to change specifications at anytime without obligation. Certifications may vary depending on country of origin. 801 Church Lane I Easton, PA 18040, USA 1.800.523.9361 11.610.252.7301 I follettice.com Innovative solutions, inspired byice Cup Locator Guides and Large Capacity Drip Tray Large open -style alcove offers an 8,375" cup clearance. The easy to locate cup guides are built right into the alcove. The sleek drip tray slides easily into the front of the alcove for ease of cleaning. Inside Hinged or Garage Style Door for Easy Access Simplifies powder refills and maintenance. Provides easy access to change lit graphic or replace the units standard florescent tube. Oversized Backlit Graphic Attracts customers. Increases impulse sales, Choose Hot or Iced Coffee graphic on PCGT3 model. Touch —Button Hot Water Cleaning System Simple, one button operation sends a powerful blast of hot water into the whipper chamber, rinsing it for easy clean-up and reducing powder build up. Easy —Serve Dispensing Tubes. Bright yellow color directs customers to proper cup placement. Extended, taper design prevents splashes. PCGT3 Preset Dispense Model Available Each adjustable station is factory preset to:12 oz. small cup; 16 oz. medium cup; 20 oz. large cup. Angled Whipping Chamber and "Brake —Type" Auger Motors To ensure perfect drinks, powder augers feature a brake -type motor that accurately stops the dispensing process at your set ratio every time. Angled chamber drain liquids far better to significantly reduce cleaning requirements. Multi —Volume Powder Hoppers Both 5 lb. and 10 lb, sizes allow operators to double the volume of top selling flavors, reducing fill times. Hoppers must be removed for refilling, virtually eliminating the wear and operating downtime caused by spilled powder. Positioning guides make it impossible to insert the hoppers incorrectly. PCGTS SPECIFICATIONS Model Hoppers Water Tank Dimensions Cup Clearance Voltage Power Cord & Plug Water Inlet Ship Weight Cube (cu, ft.) PCGI3 3 5,3 gallons 34.751 x 14.251l x 23.6251) 8.375" 120VAC, 50/60Hz 1800W/15A 6 it/NEMA 5.15P 1/4" Rare 125 lbs. 15.3 PCGT4 SPECIFICATIONS Model Hoppers Water Tank Dimensions Cup Clearance Voltage Power Cord & Plug Water Inlet Ship Weight Cube (cu. ft.) PCGI4 4 5.1 gallons 34.5"13 x 211x 23.6251 8.375" 120VAC, 50/60Hz 1800iV/15A 6 ((/NEMA 5-15P 1/4" Flare 147 lbs. 23.9 PCGTS SPECIFICATIONS Model Hoppers Water Tank Dimensions Cup Clearance Voltage Powor Cord & Plug Water Inlet Ship Vioight Cube (cu, ft,) PCGTS 5 5.3 gallons 34.7511 x 21"l'1 x 23.625"D 8.375" 120VAC, 50/60111 1800W/15A 6 (t/NEMA 5-15P 1/4" Aare 160 lbs. 23.9 34.75" 166.3cm) cm) 8.375" (2I.3cm) .M .4. 4 J 41 - fJ - •- ' i' �. `'. 75" 9cn,) 1 8.375" (21.3em) � u� _ -- 41, 23.625" (69Aom) ._—....-- 23.625" L (96.2em) PCGT6 SPECIFICATIONS Model Hoppers Water Tank Dimensions Cup Clearance Voltage Power Cord & Plug Water inlet Ship Weight Cube (cu. ft.) PCGT6 6 5.3 gallons 34.7511 x 2119 x 23.625'D 8.375" 120VAC, 50/60Hz 1800W/15A 6 ft/NEMA 5-15P 1/4" Flare 160 lbs. 23,9 34 75" (88.3c n) 0O�JV 8.375" (213e,n) 23.625" m 21.0". ---•-(53.3an) WILOUR CURTIS COMPANY, INC. 6913 Acco Street, Montebctto, CA 90640-5403 Telephone: 8022]-6]50 • 323-837-2300 Fax: 323-837-2406 www. ,)lburcurtis.corn )s 6"(T2. s - 1s) 'x> ptC.(Lt (d US 00712 - 11421 r-3226 ,cv.G itt GEMINI® INTELLIFRESH® COFFEE BREWING SYSTEMS IF L i •A(I. G•� f Perfect Heat, Perfect Timing, Perfect Brew. Brew the Perfect Cup Now. Serve the Perfect Cup Later. Brew and hold your coffee at the perfect temperature for as long as you want. IntelliFresh® remembers so you don't have to. Once you press Brew, your pre-programmed freshness requirements and desired warming temperature is automatically set. IntelliFresh® Satellite Servers are smart. They remember these settings — not only while at the brewer, but at the remote serving stand too. The exclusive design envelops the satellite vessel with gentle, digital controlled warmth, so the last cup you serve will always taste as fresh as the first. The Gold Cup Series'' Gemini® IntelliFresh® proves that high -end brewing systems don't have to be costly and complex to serve perfect coffee. MODELS: GEMTIF, GEMTIF, GEM3IF, GEM5IF, GEM5IFT ITEM NO PROJECT DATE FEATURES AT A GLANCE INTELLIFRESH® Technology - Continuously monitors and holds temperature by gently adding heat to preserve coffee flavor. • LED notification of freshness timing. • Gold Cup Series' - Digital control module ..,/t provides precise control over all aspects THE GOLD�CUPSERIES'" of brewing: time, temperature, volume, - plus specialty coffee needs from pre- infusion to pulse- brewing to water bypass. • Pre-set, one -touch Global Recipes - Based on coffee type, grind and weight. Simplifies profile setting for gourmet results every time. • Industry's most effective mineral tolerant design. Patented fast -wetting AFS Srayhead Non -immersed water temperature sensor • Encapsulated Control Board - Protects against steam, water and impact. • Field selectable for /z, 1 or 11 gal. batch brewing. INTELLIFRESH® SATELLITE SERVERS AND WARMERS • Engineered for easy maintenance - smart, water tolerant design. No foam or fiber insulation. c Temperature can be set thru the digital control board to high, medium or low to preserve peak coffee freshness - Factory set to 1857. Quality timer is set to 2 hours. 6E1131F & GEM51F (Left) 6f/451F (Right) PCGT3 SPECIFICATIONS Model PCGT3 Hoppers 3 Water Tank 5,3 gallons Dimensions 34,75"H x 14.25"W x 23.625"0 Cup Clearance 8.375" Voltage 120VAC, 50/60Hz Power 1800W/15A Cord & Plug 6 ft/NEMA 5.15P Water Inlet 1/4" flare Ship Weight 125 lbs. Cube (cu, ft.) 15.3 23.625" (60.Ocm)----...� PCGT4 SPECIFICATIONS Model PCGT4 (toppers 4 Water Tank 5.3 gallons Dimensions 34.5"N x 21"V/ x 23.625"D Cup Clearance 8.375" Voltage 120VAC, 50/60Hz Power 1800W/15A Cord & Plug 6 ft/NEMA 5.15P Water inlet 1/4" flare Ship Weight 147 lbs. tube (cu. ft.) 23.9 PCGT5 SPECIFICATIONS Model PCGT5 Hoppers 5 Water Tank 5,3 gallons Dimensions 34.15"H x 21"W x 23.625"0 Cup Clearance 8.375" Voltage 120VAC, 50/60Hz Power 1800W/15A Cord & Plug 6 ft/NEt4A 5-iSP Water Inlet 1/4" Flare Ship Weight 160 Ws, Cube (cu. ft,) 23.9 34 50" (67.6cm) 0,375" (21.3cm) ) 1 I (et Icon 23.625" (63.3cm) PCGT6 SPECIFICATIONS Model PCGT6 Hoppers 6 Water Tank 5,3 gallons Dimensions 34.75"H x 2111x 23.625"0 Cup Clearance 8.375" Voltage 120VAC, 50/60Hz Power 1800W/i5A Cord & Plug 6 ft/NEMA 5.15P Water Inlet 1/4" Flare Ship Weight 160 tbs. Cube (cu. ft.) 23.9 34 75" (60.3cm) (21.3cm) ii '1 ,41 y`1 i:.-J 23.625" (eoecon .. (63.3cm) 600.: WILBUR CURTIS COMPANY. INC. 6913 Acco Street, Montebelto, CA 90640.5403 r'etepbone: 800.421-5150 • 32333-8837-223300 Fax: 323-837-2406 www.wilbureuitis.com RLtt )&r-t'f-tar^ -1s i6,"Fize. 4^-0 ttu OCT/12 - 11421 F-3226 rev.G mars .t atmosphere is everything Document No: IND2-IOM Date: 1015 STANDARD 2 (STD2), HIGH VELOCITY 2 (HV2), EXTRA POWER 2 (EP2) AND ETL SANITATION CERTIFIED INDUSTRIAL SERIES Installation, Operation and Maintenance Manual Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing ail safety information. Failure to comply with these instructions could result in personal injury and/or property damage. Retain these instructions for future reference. OVERVIEW Mars Air Curtains are designed to cover door openings, providing both temperature control/environmental separation and flying insect control, when the building's doors are opened. Typical installation heights are: Standard 2 Series (Environmental up to 10', Flying Insect Control up to 8'), High Velocity 2 Series (Environmental up to 12', Flying Insect Control up to 10'), and Extra Power 2 Series (Environmental up to 16', Flying insect Control up to 14'). All ETL Sanitation Certified Series should be mounted at the Flying Insect Control heights referenced above. The units are typically wall mounted horizontally above the door opening. They can also be suspended from the ceiling or vertically mounted along side the opening. The units are ETL Listed for either an inside or outside mount. Heated units must be mounted on the inside or the protected side of the opening. The motors used in the Standard 2, High Velocity 2 and Extra Power 2 Series are 1/2HP, 1HP and 3HP respectively. The ETL Sanitation Series utilizes 1/21-IP and 1HP motors. The Standard 2, High Velocity 2 and Extra Power 2 Series come standard with an air intake grille. They can also be configured with an aluminum mesh air intake rN tiec.�insiead of tlae.air ke grille or in conjunction with EVIEWED FOR INFORMATION se this product only in the manner intended by the DEC 05 2018 City of Tukwila II rIAIrt_ rnnhlounnI Ejus((Ey Intertek Intertek coming in contact with potential hazards. manufacturer. if you have any questions, contact the manufacturer. Only qualified personnel should install this product. Installing personnel should have a clear understanding of these instructions and should be aware of general safety precautions. Improper installation can result in electric shock, possible injuny due to moving parts, as well as other A WARNING To reduce the risk of fire, electric shock or injury to persons, observe the following. A. Always disconnect, lock and tag power source before installing or servicing product. B. Installation work or electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire -rated construction. C. The combustion airflow needed for safe operation of fuel burning equipment in the area may be affected by the product's operation. Follow the heating equipment manufacturer's guideline and safety standards, such as those published by the National Fire Protection Agency (NFPA), the American Society of Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and focal code authorities. D. When cutting or drilling into a wall or ceiling, be careful not to damage electrical wiring and other hidden utilities. RECEIVED 1R37q CITY OF TUKWILA NOV 2 8 2018 A WARNING Precaution should be taken in explosive atmospheres. A WARNING When servicing the product, motor may be hot enough to cause pain or injury. Allow motor to cool before servicing. RECEIVING AND INSPECTION Upon receiving the product, check to make sure all items are accounted for by referencing the Bill of Lading to ensure all items were received. Inspect each carton for shipping damage before accepting delivery. Notify the freight carrier if any damage Is noticed. The carrier will make notification on the delivery receipt acknowledging any damage to the product. All damage should be noted on all copies of the Bill of Lading which is countersigned by the delivering carrier. A Carrier Inspection Report should be filled out by the carrier upon arrival and a report given to the Traffic Department. If damaged upon arrival, file a claim immediately with the carrier. Any physical damage to the unit after acceptance is not the responsibility of Mars Air Systems. UNPACKING Verify that all parts, components and accessories, and the correct quantities of each have been received. If any items are missing, report shortages to Mars Air Systems directly to arrange for obtaining the missing items. Again, verify quantities received against those on the Bill of Lading only, as multiple shipments may be involved. INSTALLATION Typical Mounting — Wall or Ceiling Mounted Horizontally Above the Door Opening 1. Remove the air intake grille(s) and/or filter(s) from the product and set aside. Only products 48" or less, except HV2 and EP2 models, are shipped with the motor fan assembly (MFA) mounted inside. 2. Measure the housing and center it over the opening. The air curtain shall be equal to or greater than the width of the opening. 3. Total of two (2) key -hole slots and six (6) pre -punched mounting holes are provided for your convenience. The 7/16" pre -punched holes (4) provided, (2) on each end for top/ceiling mounts. The 1/2" key -hole slot and 7/16". pre -punched hole (2) provided, (2) on each end for wall. mounts. These holes must be utilized to secure the product to the wall or ceiling. If n ces an holes may be drilled inside the product Mali Wh the stif spacing. All hardware is field provided b thers. 4. 5. 6. 7. 8. 9. Mount the product such that the discharge is 1" above the opening and ail obstacles. (FIG. 1) Note: If the product is installed higher than the recommended 1" above the opening, then it must be moved 3/8" away from the wall for every 1" that it is moved up. Any void between the wail and the product must be sealed, by others, to optimize performance. Use four (4) threaded rods for overhead installation or four (4) threaded bolts for wall installation. All hardware is field provided by others. (FIG. 1) If applicable, optional Adjustable Mounting Brackets, Side Extension Plates and Extended Wall Mounted Brackets are also available for installations over a Vertical Lift or Drum Roll -up type door. (Reference Accessory Installation Supplement) If applicable, for tandem installation or products mounted side by side, allow no more than 6' between the two products. For overhead installation using threaded rods, the products may require a beam, by others, to span the full distance of the mounting length. (Reference Accessory Installation Supplement) All wires must be connected internal of the unit and some knockouts are provided. However, it may be necessary to create your own knockout, as required. The unit must be wired per NEC and local codes. FIG. 1 ALTERNATIVE THREADED RODS MOUNTING FOR OVERHEAD INSTALLATION (BY OTHERS) STANDARD THREADED BOLTS FOR WALL INSTALLATION (BY OTHER) TYPICAL WALL MOUNTING 1" ABOVE DOOR Motor Fan Assembly Installation and Electrical Field Wiring 1. Once the housing is installed over the opening, the Motor Fan Assembly (MFA) must be re -placed and securely fastened. For products with the MFA shipped loose, wing nuts or hex nuts are provided inside the unit (FIG. 2). For heated MFA installation, reference Heated Products Supplement Sheet, 2. The unit and any optional accessories must be wired with the proper volte to the junction box per the wiringgagratt. (FI1 . , unbeatedproducts only) . r„� 1141 TOP I tOUt'riNG HOLES ► 3. All 3 phase motors are bi-directional, which means they can rotate in either direction. Follow directional arrows on the blower wheel housings for proper rotation. if the motor Is rotating incorrectly, switch two of the 3 phase power or motor leads and the motor will rotate the opposite direction. Make sure all motors are turning in the same and proper direction. (FIG. 2) 4. Replace the air intake grille(s) or filter(s) once the product has been properly tested. MOUNTING BOLTS FOR MFA PAN \ `WALL MOUNTING HOLES FIG. 2 • 4'ANG NUTS OF HEX / NUTS PROVIDED TO r SECURE MFA TO / HOUSING EIGHT (8) SCREWS FOR INTAKE SCREEN J Typical Door Limit Switch Installation for Split Sliding Doors Typical Door Limit Switch Installation for Commercial Swing Doors Typical Door Limit Switch Installation for Industrial Roll Up or Lift Doors OPENING Field Conduit Wiring Wheel Rotation CONTROL PANEL TO - PO411ER PANEL 1 FIG. 3 NOTE For accessory installation, reference Accessory Installation Supplement. For heated products, reference Heated Products Supplement. START-UP This product has been assembled and tested at the factory prior to shipping. The following procedures should be performed to assure its performance. Before continuing with the start-up, it is important to recognize the safety controls furnished with the unit. QWARNING The following items must all be completed by a qualified installer and checked off when completed A. Re -check that the product has been installed properly and is level and secure. B. Check all terminal screws are tight and field wiring is connected in accordance to National Electrical Code and wired per the enclosed wiring diagram. For electric heated models, ensure that the coils are secured and not touching each other on any metal surface. C. Verify proper voltage prior to powering the product. (See product label for reference). D. Check all field wired components "if supplied" are wired correctly. E. Check that the inlet air supply and the discharge air supply are free of obstructions. F. Check that all air filter(s) and/or air intake grille(s) are in place and installed properly, as originally shipped. G. Verify voltage to the product once more and turn power on. H. Regardless of whether the product is mounted on the inside or outside of the door opening, set the air directional vanes in the discharge nozzle slightly outward to approximately 10-15° towards the outside, or the wind load. (FIG. 4) OUTSIDE , a. lj %j: FIG. 4 INSIDE t. For products with control panels, turn the HOA (Hand - On -Auto) selector switch to "On" position and open the door to energize the product. For products without 3 a control panel or an On/Off switch, open the door to energize the product. J. If heated products are installed, reference Heated Products Supplement. K. For three phase units, verify direction of rotation of blower wheels (note direction arrows on the blower wheel housing). Correct if needed by changing polarity of three phase power. L. VERY IMPORTANT Using a clamp meter, measure the amperage to each motor and ensure that they do not exceed the amperage listed on the product label. M. If applicable, adjust the air intake grille(s) such that the output air stream reaches the floor. For temperature control and environmental separation applications, the air stream should reach the floor with sufficient strength to create an air seal around the door opening without creating turbulent mixing of the inside and outside air. For flying insect control applications, the air stream should reach the floor with maximum strength. If after proper installation and adjustment, the product appears to be producing too little or too much air for the application, contact the manufacturer. A WARNING Prevent hazard of electrical shock. More than one disconnect switch may be required to de -energize this product. MAINTENANCE A WARNING To reduce the risk of fire, electrical shock or injury to persons, observe the following: A. Maintenance is to be performed only by qualified personnel who are familiar with local codes and regulations and are experienced with this type of product. B. Before servicing or cleaning the product switch power off at service panel and lock service panel to prevent power from being switched "ON" accidentally. Routine maintenance is required to keep this product operating at its peak performance and efficiency. Over time, the housing, air intake grille, air intake filter, blower wheels and motor(s) will accumulate a build up of dust, debris and other residue. It is imperative to keep these components clean. Failure to do so will not only lower operational efficiency and performance, but also reduce the useful life of the product. The time between cleanings depends on the application, location and daily hours of use. On average, under normal use conditions, the product should require a thorough cleaning once every six (6) months. To clean the product, perform the following: 1. Verify the product has been disconnected from the power source. 2. Use a damp cloth and either a warm mild soapy water solution or bio-degradable degreaser, to wipe down the exterior components of the housing. 3. To access the interior of the product, remove the air intake grille and/or air intake filter. This is accomplished by removing the eight (8) self -tapping screws on the face of each air intake grille/filter. 4. Thoroughly clean the air intake grille/filter. 5. Remove the motor fan assembly (MFA) from inside the air curtain housing. This is accomplished by loosening the watertight fitting and pulling the cord out (3 phase power) or by the quick disconnect plug on the motor (1 phase power). Then remove the two (2) wing nuts on the out board sides of the MFA pan. Care should be taken to avoid the MFA from tipping over. 6. Remove the MFA from the unit and thoroughly wipe down the motor, blower wheels and blower wheel housings. Be careful not to submerge the motor in water or spray it with a water hose. 7. The motor(s) require no additional lubrication. They are permanently lubricated and feature double sealed ball bearings. 8. To re -install the product, reverse the procedures above. 9. Reconnect the power source to the product 10. If you have any questions regarding the maintenance of the product, contact the manufacturer. SPECIAL APPLICATIONS Outdoor Installation For outdoor unit special consideration may be required for enclosure, motor, wheel and other components to minimize damage caused by exposure to the outdoor elements. Contact factory for special construction and costing. Freezer and Cooler installation Air curtain must be mounted on the warm side for optimal performance. Variable Frequency Drive (VFD) is strongly recommended to control the air curtain air flow velocity at the floor level. High humid areas may require de -humidifier or additional defrost cycle to minimize condensation and freezing for freezer applications. We recommend the air curtain unit to not replace doors but work in conjunction with door opening sequence cycle. Contact factory for details. • m O N O get N 0 AI O O O O 0 0 t+1 N O N w w 0 WW 0 w 0 0 O PI 3 Ob o 0 0 N CO N It W R' 0 0 0 N CO f 1 r REVISIONS No chanoes snail be made to the scope of work witnout or,or approval of the Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan nevi=. OL Fy Ill_ P Tm t No. lQ!" Plan review approval is subject to errors ano omissions Approval of construction aocuments does lot authorize the viol. Ion of any aaopte• code or ordinance Re - •• I • f � proved Fi - • opy and By. Date: BUIL y of Tukwila ING DIVISION NBo37H SEPARATE PERMIT REQUIRED FOR: E Y Mechanical Er Electrical f Plumbing Gas Piping City of Tukwila BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED DEC 05 2018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA NOV 2 8 2018 Ki(\2L IIIWiI I111111 _I 1 MENII 2nd 4 BEER i(36"x30") LT 4' GONDOLA 3 58" H 4' NUTR/ ENG BARS 4' T.H. FRITO LU m 0 Ole I 5' 6' I PA \ THEATER CANDY 5' 6" 1 0G4 I M PRIMARY��c I ] BEER L_ J• IN PROMO I f3] I 1 5 IL24„ WALL UNITS 58" H 2' CANDY 24" M1111 11f1 O 1,4 0 S J GONDOLA. 1 58" H. 2' CANDY BASKETS __, r__E--... CART i I 1 n n 1 J \ 4' AUTO SITE 82941 (formerly 5515) NOTES ADDED 03.22.2018 BY PM DESIGN GROUP, LYNNWOOD, WA DRAW1N DESCRIPTION: SITE 82941 (formerly 5515) : STORE LAYOUT 3' JERKY .11 NNW GONDOLA 4 50" H 36" ko GPI / 4'-7 1/2" — r. `NOVELT% r I WI o"I Lam_ SODA WED FOR �w OMkAPLIANCE PROVED DEC 0 5 2G18 NOTE. REFER TO MANUFACTURES CUT SHEETS FOR ALL NEW EQUIPMENT NEW COFFEE MARKERS TO REPLACE EXISTING, REUSE WATER, DRAINS ---AND POWER HOOK-UP. NOTE TO CONTRACTOR TO PROVIDE AND INSTALL RPBA IF NOT EXISTING. PLUMBING WILL BE A SEPERATE PERMIT. NEW SELF CONTAINED REFRIGERATED END DISPLAY, PROVIDE NEW OVERHEAD POWER DROP. HEALTH DEPARTMENT TO VERIFY OPERATING TEMPERATURE PRIOR TO USE. NEW AIR CURTAIN / AIR BLOWER TO KEEP FLYS OUT. MOUNT ABOVE ENTRY DOOR. CONTRACTOR TO PROVIDE A SAFETY SPOTTER FOR ALL AND ANY OVERHEAD WORK IN THIS 24 HOUR STORE TO PROTECT THE CUSTOMERS. GONDOLAS COLOR BEIGE SQUARE FOOTAGE 1 541 .0 sq.ft C 3/16" =1' - 0" ity of Tukwila BUILDING DIVISPOSED UPGRADES PLAN 41� DATE: JAN. 2017 RECEIVED CITY OF'Tti(WILA NOV 2 8I 2018 PERM1'T CEN'iER I BP ARCO I SITE # 5515: 15252 PACIFIC HWY, — T1,KWtt.1% DWG. NO. SCALE 04-0568—B 3/16'=1 DATE DRAWN BY f RS/M T7 I S H 0 P C 0 USA,INC. HOUSTON, TX. 77040 OUS(7 3)P934-2900_ iVas 15252 International Blvd tiii4Wilotit tAitk Abstv0 Aldirt.4 4r02.4104-1 LJ WeVAii.ITM fiTee.:C4 Pja 1_`4":1k..7gD S.•154t h • - I 75 1.4 ttfs r arr-,m 5252"in+crnatIonal Southcenter Blvd r r ceit L'j 60 + b000 q-O hieekKILalANCE APPROVED DEC 0 5 2C13 GoorroF-Trux-ww-A NOV 2 8 2098 PERMIT CENTER City of Tukwila GO TL414-W t(, tNTWI.( WvreNt1 (►wp gle Iv aps -8-7-46=auu-ciice-i l Lei Blvd Icy f'k v1 rM ' P `1'r Tukwila, Washington Google, Inc. Street View - Aug 2017 int x"MIckioikt. P'HOW CODE COMPLIANCE APPROVED DEC 0 5 2018 Plitt ,.s T..1....:�_ 1 Image caR1om avaan� rQ 2918 Google RECEIVCITY OF 11.1KWILL, NOV 2 8. 2013 PERMIT CENTER 5ERMIT COORD COPY c:7 PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D18-0374 DATE: 11/28/18 PROJECT NAME: ARCO STATION - AM/PM SITE ADDRESS: 15252 TUKWILA INTERNATIONAL BLVD X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: -- Building Division II 1 AO `)-°1 Public Works 110 A'\ Fire Prevention Structural i1->o-Ig 1 n 13 ij//l-II)- Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) REVIEWER'S INITIALS: DATE: 11/29/18 Structural Review Required DATE: n APPROVALS OR CORRECTIONS: Approved n Corrections Required (corrections entered in Reviews) Approved with Conditions Denied (ie: Zoning Issues) DUE DATE: 12/27/18 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: o Home Espanol Contact: Q Search L&I Safety & Health Claims & Insurance 4111111Washington State Department of % Labor & Industries A-Z Index Help My L [ Workplace Rights Trades & Licensing SUMMIT PROPERTIES & DEV CO INC Owner or tradesperson Principals MATISSE, CARL ASHCROFT, PRESIDENT Doing business as SUMMIT PROPERTIES & DEV CO INC WA UBI No. 604 113 208 6445 CITATION DR STE G CLARKSTON, MI 48346 248-625-4711 Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. ........._.... Meets current requirements. License specialties GENERAL License no. SUMMIPD834KP Effective — expiration 06/01/2017— 06/01/2019 Bond Western Surety Co Bond account no. 71903472 $12,000.00 Received by L&I Effective date 05/08/2017 04/27/2017 Expiration date Until Canceled Insurance Employers Mutual Casualty Co $1,000,000.00 Policy no. 5s24695 Received by L&I Effective date 01/24/2018 01/13/2018 Expiration date 01/13/2019 Insurance history Savings .......... No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, ut some debts may be recorded by other agencies. Infraction no. EHENS00531 Issue date 06/13/2018 Violation city CLARKSTON Type of violation ELECTRICAL CITATION Description Covering or concealing installations prior to inspection. Not Satisfied RCW/WAC 19.28.101 RCW Violation amount $250.00 Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 659,284-00 ............................... Doing business as SUMMIT PROPERTIES & DEVELOPMEN Estimated workers reported Quarter 3 of Year 2018 "11 to 20 Workers" L&I account contact T1 / SHARYN LOCKE (253)596-3850 - Email: FSHA235@Ini.wa.gov Account is current. Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid ....................................................._ ....... No debarments have been issued against this contractor. Workplace safety and health No inspections during the previous 6 year period. C� Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington.