HomeMy WebLinkAboutPermit B94-0185 - BOEING #21-02 - RESTROOMSCity of 71thwttA (206) 431-3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 BUILDING PERMIT Permit No: B94 -0185 Type: B -BUILD Category: ACOM Address: 3417 S 120 PL Location: Parcel #: 102304 -9069 Zoning: M1 M2 Type Const: III -N Gas /Elec: Wetlands: Water: 125 Contractor License No.: BOEINC294ML CM Status: ISSUED Issued: 06/14/1994 Expires: 12/11/1994 Suite: Type of Occupancy: WAREHOUSE Slopes: Y Sewer: VAL VUE TENANT BOEING #21 -02 3417 S 120 PL, SEATTLE, WA 98168 OWNER SABEY CORPORATION 201 ELLIOTT AVE. WEST, SUITE 400, SEATTLE WA 98119 CONTRACTOR BOEING INC. Phone: 206 544 -2975 9725 EAST MARGINAL WY S, SEATTLE, WA 981242207 CONTACT TERRY BENNETT Phone: 206 544 -2975 P.O. BOX 3707,M/S 46 -87, SEATTLE, WA 98124 ******* * * * * * * * * * ** * * * * * * * * * * * ** * * * * *: ***** * * * ** ** * * * ** * ** * * *!t * ** * * * * ** ** *pit* Permit Description: INTERIOR REMODEL OF RESTROOMS. SETBACKS Units: 001 Front: .0 Back: .0 Buildings: 001 Left: .0. Right: .0 Fire Protection: SPRINKLERED UBC Edition: 1991 Valuation: 9,000.00 Total Permit Fee: 182.70 ******************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Center Authorize Signature id D(r-Jld--1 ate I hereby certify that I have read and examined this permit and know the sane to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this builr§.permi Signature: Date: 4Z /-,L c/ Print Name: Title: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. All PERMITS ISSUED FOR NEW CONSTRUCTION, REMODELING, OR DEMOLITION PROJECTS REQUIRE CONSTRUCTION, DEMOLITION AND LANDCLEARING WASTE MATERIAL FROM THESE PROJECTS TO BE RECYCLED AT A KING COUNTY LICENSED OR APPROVED FACILITY, OR TAKEN TO REGIONAL DISPOSAL FACILITIES. CITY OF TUKWIL.- Department of Coro, minify Development -- Permit Cent& 6300 Southcenter Boulevard - #100, Tukwila, WA 98188 (206) 431 -3670 Building Permit Application Tracking PLAN CHECK NUMBER 13'9'4- 0185 PROJECT, NAME SITE ADDRESS i S I -d • 'PL SUITE NO. INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that the status of the project may be ascertained at any time. • Plan corrections shall be completed and approved prior to sending to the next department. • Any conditions or requirements for the permit shall be noted in the Sierra system or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ", date and initial. DEPARTMENTAL REVIEW "X" in box indicates which departments need to review the project. QUIREME O PUBLIC WORKS O OTHER UTILITY PERMITS REQUIRED? PUBLIC WORKS LETTER DATED: INIT: 61V INIT: BUILDING - final review P2 BUILDING OFFICIAL CERT. OF OCCUPANCY? °Yes 5'No UBC EDITION (year): tT REVIEW COMPLETED I6 /ctq IN T: AMOUNT OWING: gf CONTACTED IP •ems I (� f`� Qx.) BY: init. DATE NOTIFIED (0l l ! _ "� 2nd NOTIFICATION BY: . (init.) 3RD NOTIFICATION BY:. (init.) BUILDIh.; PERMIT APPLICATION CITY OF TUKWILA Department of Community Development - Building Division 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 /$/70/3 -00 PLAN CHECK NUMBER APPLICATION MUST BE FILLED OUT COMPLETELY DESCRIPTION AMOUNT RCPT # DATE BUILDING PERMIT FEE [al hr 'iMIIIIIIIIIM O. -C) 4-, j NATURE OF BUSINESS: AJRPI ANFS -- Ib--' 5•- )10-514- ,- 11D- (M- PLAN CHECK FEE BUILDING SURCHARGE WIL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE No ❑ Yes IF YES, EXPLAIN: FIRE PROTECTION FEATURES: X1 Sprinklers g Automatic Fire Alarm / OR HAZARDOUS MATERIALS IN THE BUILDING? System OTHER: ZIP TOTAL - I S3.1D 5i- lb -94 -- SITE ADDRESS SUITE # cW /7 . /�d0� ° ,2/-4.2 - -�� VALUE OF CONSTRUCTION - $ 4 om o , ASSESSOR ACCOUNT # AMMO /O,2.3Dy 90‘.11 PROJECT NAME/TENANT BOEING DEFENSE AND SPACE GROUP TYPE OF O New Building ❑ Addition Tenant Improvement (commercial) Li Demolition (building) WORK: ❑ Rack Storage ❑ Reroof ❑ Remodel (residential) ❑ Other DESCRIBE WORK TO BE DONE: BUILDING USE (office, warehouse, etc.) NATURE OF BUSINESS: AJRPI ANFS requirements may need to be met. Please explain: WILL THERE BE A CHANGE iN"IISE7 —V No ❑ Yes If Yes, new building SQUARE FOOTAGE - Building: /07 3_40 Tenant Space: Area of Construction: ()op WIL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE No ❑ Yes IF YES, EXPLAIN: FIRE PROTECTION FEATURES: X1 Sprinklers g Automatic Fire Alarm / OR HAZARDOUS MATERIALS IN THE BUILDING? System PROPERTY OWNER BOEING DEFENSE AND SPACE GROUP PHONE ADDRESS P.O. BOX 3707 M/S 46 -87 SEATTLE, WA. PHONE ZIP 98124 -220i CONTRACTOR SAME ADDRESS ZIP WA. ST. CONTRACTOR'S LICENSE # BOE INC -294ML EXP. DATE /_ 0! _ 9S ARCHITECT PHONE ADDRESS ZIP I HEREBY CERTIFY THAT ;I HAVE READ .AND .EXAMINED THIS APPLICATION AND KNOW THE" SAME TO BE TRUE AND CORRECT, AND 1 AMM AUTHORIZ ' : TO APPLY FOR THIS PERMIT BUILDING OWNER OR AUTHORIZED AGENT SIGNATURE PRINT NAME TERRY BENNETT ADDRESS PO BOX 3707 M/S 46 -87 SEATTLE, WA. CONTACT PERSON TERRY BENNETT PHONE DATE PHONE 544 -2975 /4 /99,x' CITY/ZIP 98124 -2207 544 -2975 APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. Handouts are available at the Building counter which provide more detailed information on application and plan submittal requirements. Application and plans must be complete in order to be accepted for plan review. VALUATION OF CONSTRUCTION Valuation for new construction and additions are calculated by the Department of Community Development prior to application submittal. Contact the Permit Coordinator at 431 -3670 prior to submitting application. In all cases, a valuation amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Building Division to comply with current fee schedules. BUILDING OWNER / AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitations. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Building Code (current edition). No application shall be extended more than once. If you have any que- out our process or plan submittal requirements, please contact the Dept unity Development Building Division at 431 -3670. DATE APPLICATION ACCEPTED 14y 1 6 iss' 5 -16 -99- DATE APPLICATION EXPIRES 0 16-91- 0 J! COMMERCIAL NEW COMMERCIAL BUILDINGS /ADDITIONS 1-1 Completed building permit application (one for each structure) riAssessor Account Number Two sets (2) of the following: Specifications SIA3MITTAL CHECKLIST L� U Structural calculations stamped by a Washington State licensed engineer Soils report stamped by a Washington State licensed engineer Topographical survey Energy calculations stamped by a Washington State licensed engineer or architect Legal description Working drawings, stamped by a Washington State licensed architect, which include: • Site plan • Architectural drawings • Structural drawings • Mechanical drawings • Elevations • Civil drawings • Landscape plan CJ Completed utility permit application (one for entire project) Six (6) sets of civil drawings NOTE: See utility permit application and checklist for specific utility submittal requirements. RACK STORAGE Completed building permit application 1 1 Assessor Account Number Two (2) sets of plans, which include: 11 Building floor plan showing: • Entire space where racks will be located • Exit doors • Dimensions of all aisles . Tenant space floor plan showing rack storage layout, aisles and exits. NOTE: Include dimensions of racks (height, width and length), aisles and exit ways on plan. Structural calculations stamped by a Washington State licensed engineer (rack storage 8' and over).. RESIDENTIAL NEW SINGLE-FAMILY DWELLINGS /ADDITIONS [ 1 Completed building permit application (ono for each structure) 11 COMMERCIAL TENANT IMPROVEMENTS Completed building permit application (one for each structure or tenant) Assessor Account Number Two (2) sets of construction plans, which Include: . Site plan • Location of tenant space • Existing and proposed parking • Landscape plan (if applicable, i.e., change of use) Overall building plan •Tenant location • Use of adjacent (common wall) tenant • Overall dimensions of building or square footage Floor plan of proposed tenant space • Tenant space plan with use of each room labelled. • Exit doors, egress patterns. • New walls, existing wail, and walls to be demolished. Construction details • Cross sections showing wall construction and method of attachment for floor and ceiling. Structural calculations stamped by a Washington State licensed engineer may be required if structural work is to be done (2 sets) NOTE: If any utility work is to be done, submit separate utility permit application and plans. REROOF Completed building permit application (one for each structure) Assessor Account Number Narrative describing existing roof, material being removed, and Material being installed.:,.; NOTE: A certification letter is required prior to final inspection and sign - oft of the permit. ANTENNA/SATELLITE DISHES Completed building permit application. Assessor Account Number 11 Two (2) sets of plans, which include Site Plan (showing building and location of antenna/satellite dish) Li Details antenna/satellite dish and method of attachment rai Structural calculations stamped by a Washington State licensed engineer may be required Legal description r1 Assessor Account Number Two sets (2) of working drawings, which include: • Site plan ---- -► (On plan, show closest hydrant locadon. • Foundation plan include access to building,: showing • Floor plan width and length of access.) • Roof plan • Building elevations (all views) • Building cross - section • Structural framing plans Washington State Energy Code data ri Completed utility permit application Six (6) sets of site plans showing utilities NOTE: Building site plan and utility site plan may be combined. See utility permit application and checklist for specific submittal requirements. Additional topographical and soils information may be required if unique site conditions. RESIDENTIAL REMODELS riCompleted building permit application (one for each structure) r1 Assessor Account Number 11 Two (2) sets of working drawings, which include: • Site plan • Foundation plan • Floor plan • Roof plan. • Building elevations (all views) • Building cross- section • Structural framing plans NOTE: .If any utility work Is 1o. be done provide utility permit application REROOFS n Completed building permit application (one for each structure) Assessor Account Number 1 Narrative describing existing roof, material being removed, and matenah pa)nigiInstalled NOTE: A cettiflcation letter is required prior to final Inspection and sign -off of the permit ' <' *******•*? r* k** kh******. t*k****.• k** kA* * *k * * * ** * **** * *k* ** * *.4 * * *k **** CITY OF TUKWILA, WA y 1R)NSMIT :4 **k*kk* ***k* *******'rk* *** k*•****** k* * *** * ** ** *•* **.t•*k * *** **• **k** TRANSMIT plumber: 5_1000556 Amount: 182.70 05/16/9M /9, 0 Pei ^ »it No B94 -018 Type: 0--BUILD BUILDING PERMIT Pdreel No: 102304-•906. - Site AdWresss 3417 s 120 PL Payment Method: CASH Natation: BOEING COMPANY init: SAO ************* k* k**• k***•**\A, k********* *** * ***k****k•k *** ** * *k ** *A**•k Paid 108.00 70.20 4.50 182.70 Ac•caurlt' Co4le. ` 000/32.100 000/345.830 000/386.9Of1 Description BUILDING - NONRES PLAN CHECK -' NONRES ` STATE BUILDING SURCHARGE Total (TW1•s.:Payment) s Total Fees: Total All Payments: Balance: 182.70 i. 82.7 0 .00 GENERA 182.70 TOTAL 182.70 CASH 182.75 CHANGE 0.05 1960A000 06:56 CITY OF TUKWILA Address: 3417 S 120 PL Suite: Tenant: BOEING #21 -02 Type: B- BUILD Parcel #: 102304 -9069 Permit No: B94 -0185 Status: ISSUED Applied: 05/16/1994 Issued: 06/14/1994 •k•k-k•k ***** * ** **** ** ***•k•k•k** *** •k•k** * *•k ** ***•k* *•k * ***-k**•k k*•k * **•k** k *** *** k *•kit* Permit Conditions: 1. No changes will be made•to:,th.e'.`p,lans,;; u.n 1';e.s;s,•- approved by the Architect ,and the Tukwila `Bu filing �Divlsio,j 2. Plumbing Permit stial,l be obtained through the Seattle -King 'County Depar treat "of Public Health Plumbing wi.11' °be, inspected by that agencyk,`y 'i.ncludin'g all gas. pi,,ping (296 -4722) x: .F1 -.,, .� :' ' 3. Electrica „l�, permit .''S,ia.�11A be:;,ob�t"alned '''through 'the.t,Washingtnn State Division o`f Labor,, }and Industries and ,a,„11 electrical work wi.fl., be :''i`nspected *by tha,t.'‘.'g,ency (248 - 6630) 4. All mec`'nical work " -shall be. under separate permit tir`oug • the C: of :4Tukwi l a . ;� t 4 ,, • maintY • 5. All pe•`mit�s. inspection %r�ecor•ds..,,,,:.and approved plan's sh,a.:1,41' be �kined ai.lable athe ,jo,b•'-'site prior to the start :.o;f any; ,cansitructio'n. Thes'e•'•doctu'ments ,are to be maintai.:ned,,;�% ava1 ablef• unti;:l final•:;,-i'nspec,tion appr.4'va':1"••;i..s granted f ' 6. Any,tnew ceiling grid and ll,ght .i'•ic.tue installation i,s re u'iired to me,`et-� lateral \braa'oing requir:eroent;s for Seismic Z o tom, . ,, t. ;, i, .. }, _.:..., 7. Parstion; wa11s a,t'tached•°`to'•ce.i 1 inrg,. gr.id._must be late.ral�l.y.;} bracad �irt over eigil-t• (8) feet';i'n l' ngtht. ,. � w' • 8. Any y'�e. CposedF, in�su1at'i�on - ,:backing °�- lmat'er,;ia�,l:� shy -1,1 have a F,1ane; Spread Rating o.f 25 or less, and lriater'ialt-- •sha.1-.�l bear :; ide,nt- f i ca'' i ni;sshh” ,win the fire perforn ance°°4ra�t.i..ng thereof-. ,,,,4 9. All �co st��uction,$ to be done in con'fo'ram ce with ap•prove:d�- ^�' p 1 ans` a�,,» d ,( equ i re' jents of the Un idfor7m Bu i l i`i•rlg,`� Code (1`991r Edit 0), as amended by the Washi.ngto0, St t Blli,l.ding Code, Unifor echanalycal Code (1991 E,dintionY40„,4h.d�. Washington St• 't ¢ Energy' C' r 4 •j,§ 1 lam: 'o e,: (1991�rSecon:d Edition). y; ,£fix!:;. /4-.7 10. Validity of, tPerrjflit��. The' .i;ssuance of a permit or 4a ,p.ro0i1xo plans, spe`c�if cat ions and computations shall not51oe' cFon- strued to b'e;:'a permit for, or an approval of, any vlol,,a`t`ion of any of the; prou•i s i ons of ��; h g•ode br of any otter.''' ordinance of the ,fj�ur lsdictio'n.0 No per It presuming�'to give fpr authority or viol'abe;l.ar.:,.cancel`s,the provisions ":of this code shall be valid. E INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 egg 0i 85 PERMIT NO./ (206) 431 -3670 Project: Z I OZ Type of Inspection: ,.._ Address: l7 S /2a Pk- • Date Called: Spada! instructions; Date Wanted: Z - ,/ ^ RS-- am. p.m. Requester: � +\ 6� Phone No,: ,J Approved per applicable codes. D Corrections required prior to approval.. COMMENTS: Inspector: c Date: Z �S- ❑ $30.00 REINSPECTION FEE REQUIRED. Prior to relnspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. LI ecut No.: '.433iX`�s: INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) 431-3670 Project: i ale a......) Type of Inspection: matt) A 'dress: 2 ff i e l l g p i o I . te . . , AppmrAwr Sp .1 s ruction :93?) / 1/ 4 .- / 4/ O Date Wanted: ir . . . Requester: " Phone No.: ViCaga / 0 Approved per applicable codes. Corrections required prior to approval. COMMENTS: 1 itit-011-3 "1 usi 1 TIA % N) LI 0" OF —(1A■C R-Let cr-- i rf 11.- ittAra Yti. S • . t _ IInspector: Date: 9fr y5,/ 0 $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Egerpt No,: INSPECTION RECORD' 0 Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) 431 -3670 Project: / /} 1 0 r Type of Inspection: Address :I /// 7 ,5-, / /2 Date Called: /�� Spec Instructions: / Date Wanted: /l Cja p.m. Requester. jLJ • ' . I' r /ASV / cg, Approved per applicable codes. - 0 Corrections required prior to approval. COMMENTS: ifiall1111111111MIENI 1-6 /I O $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: 0 INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 O/,; 5 • 4. y__. (206) 431 -3670 Proj e Ba -pt et, I V—d Type of Inspection: � � rig • , :. ;J7 /7" 5. / PL D e Called: r / • .: Instructions: Date wanted: 7'`6 ""/ Cirdp.m. Requester Dv-74 ( ) q/l '— Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: ' : G-LAPP c)14 -- i°o Garr e.r ❑ $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. IRS ,• ge. Date: ir"""t"rm .. .. „*"""r'*S �_ . "piM1w;.x,�r.�a'ti 6'i'.p,Tid. 'e4a aY' "' 4 M• City! of Tukwila Fire Department Project Name John W. Rants, Mayor TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Thomas P. Keefe, Fire Chief Permit No. . / I - O /e'er Address J >1O • /rte pt. Retain current inspection schedule Needs shift inspection .A Approved without correction notice Approved with correction notice issued Suite # Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: FA 5/ Authorized Signature 9 /'5/9V to FINALAPP.FRM T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax• (206) 575-4439 Feb 01, 1995 City of Tukwila John W. Rants, Mayor Department of Community Development Rick Beeler, Director TERRY BENNETT P.O. BOX 3707,M/S 46 -87 SEATTLE, WA 98124 RE: BOEING #21 -02 Dear Permit Holder: Our records indicate that on Mar 1995, one hundred and eighty days will have passed with no inspections having been called for under Tukwila Building Permit Number B94-0185. Unless you call for an inspection, or obtain a written extension from the Tukwila Building Official prior to that date, your above referenced permit will become null and void on Mar 14, 1995. If your project has been completed please call for final. If you are actively working on it please notify our office. If you have any questions or need further information to obtain an extension on your permit, please call the Tukwila Building Divison at. 431 -3670. Sincerely, L( gL Sylyia Osby Acting Permit Coordin:'or Department of Community Development 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 (206) 4313670 • Fax (206) 4313665 City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 Fire Department Review Control #B94 -0185 (511) John W. Rants, Mayor June 8, 1994 Re: Boeing Company Building #21 -02 - 3417 South 120th Place Dear Sir: The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. No point in a sprinklered building may be more than 200 feet from an exit, measured along the path of travel. (UBC 3303(d)) Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 12.106(c)) Exit hardware and marking shall meet the requirements of the Uniform Fire Code. (UFC 12.106 - 12.111) Obstruction;, inclu in the required w. as permitted by obstructed in a ,4 material or mater or render ,.the exi ieng-. storage, shall not be placed •.of.. an exit, except projections ins,Code. Exits shall not be rrd shall remain free ,of any 4; presence.:would obstruct ius:,. (UFC 12.104(a)) 2. Sprinkler ,protect i opT .ha 1 1 be 'extended to all areas where required,'.inc,luding,.a11 enclosed areas, below obstructions and' .under .overhangs greater than four feet wide. (NFPA Refrain from blocking sprinkler coverage with City oY Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 Page number 2 John W. Rants, Mayor shelving. NFPA standard #13 states that any shelving or decks in excess of 4 feet in width will require installation of sprinklers thereunder. All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recognized by The City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1646) All sprinkler system plans, calculations and the contractors Materials and Test Certificates submitted to The Tukwila Fire Prevention Bureau must be stamped with the appropriate level of competency seal. (WAC 212 -80) Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1646) 3. All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 4. When walls and ceilings are required to be of fire resistive or noncombustible construction, interior finish materials shall meet the requirements of U.B.C. 4203. The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 42 -B of The Uniform Building Code. (UBC 4204(a)) 5. The total number of fire extinguishers required for City 01 Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 John W. Rants, Mayor Page number 3 your establishment is calculated at one extinguisher for each 3000 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 10B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (NFPA 10, 3 -1.1) The inspection tag on the fire extinguisher is required to have the date the inspection or maintenance was performed and the initials of the person performing the inspection or maintenance. (NFPA 10, 4- 3.4.2) Maintain fire extinguisher coverage throughout. Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Yours truly, The Tukwila Fire Prevention Bureau cc: T.F.D. file ncd si CITY OF TUKWILA Id: ACTP125 Keyword: @ACTM User: 1677 Activity Table Processing Permit No: B94 -0185 Status: PENDING 06/07/94 BUILDING PERMIT Tenant }BOEING "` #21 -02 Address: 34].7S: 12 03- r PL' Type: B -BUILD Vers: 9101 Screen: 01 Base Information Parcel No: 102304 -9069 Owner: SABEY CORPORATION Validated By: SAO Plan Ck Approved: / / Status: PENDING Applied: 5 /16/1994 Issued: / / Active /Inactive: A Completed: / / To Expire: / / C of 0 Issued: / / Bus Lic #: Final Notice: / / Nature of Work: INTERIOR REMODEL OF RESTROOMS Location: Category: ACOM (N= NEW /A= ADD /ALT + SFR,DUP,TRI,APT,MH,COM,IND) Zoning: Mi M2 CM Gas /Elec: Census Code: 437 # of Units: # of Bldgs: 1 Pub Own:N Streams: Slope: Y Wetlands: Water:125 Sewer:VAL VUE Setbacks - North: .0 South: .0 East: .0 West: .0 Valuation: 9,000.00 Fire Protect:SPRINKLERED Type Const: IIIN Type Occ:0025 WAREHOUSE UBC Edition: 1991 Occupant Load: Occupancy Grp: F7= Update, F2= Previous Line, F1= Screen Index, ESC = Cancel Update CITY OF TUKWILA Id: ROUT130 Keyword: @ACTM User: 1677 06/07/94 Activity document routing maintenance. BUILDING PERMIT Permit No: B94 -0185 Tenant: BOEING #21 -02 Status: PENDING Address: 3417 S 120 PL Route: 1 Current Route Line: 3 of 6 Packet Units Description Station Status Received Assigned Complete aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa Packet Units Action Station Initials Status Received Assigned Completed BUILD 01 01 E BLDG oiCEN -' Approved 05/18/94 06/07/94 06/07/94 Priority (0 /low..9 /high): 0 Regular hours (HH.MM): .00 Overtime Hours(HH.MM): Comments 1 2( ] 4[ „ RIRP PLEASE'REVIEW� 'AND °- COMMENT., ] 5 [ kWBY1s4KEW, ] 6[ ] 7[ ] 8[ ] 9[ ] aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa F1 =Help, ESC =Exit current screen. j— DETACH TO DISPLAY CERTIFICATE - DEPARTMENT OF LABOR AND INDUSTRIES THIS CERTIFIES THAT THE PERSON NAMED HEREON IS REGISTERED AS PROVIDED BY LAW AS A GENERAL. REGISTRATION NUMBER EXPIRATION DATE ' 01 BOEING *2941'IL EFFECTIVE DATE 01/01/95 07/1.3/71 BOEING COMPANY, TH P 0 BB0X 3707 MAIL. STOP 1F -09 SEATTLE WA 981242207 STATE OF WASHINGTON t DETACH TO DISPLAY CFRTIFICATF .J F625. 052.000 (3-92) CITY OF TUKWILA MAY 16 1994 PERMIT CENTER • BOH� NH BAG. 21 VICINITY MAP .I - 14 -01 KING COUNTY AIRPORT Drrltt .�, CENTER (FAA) FROM DOWNTOWN SEATTLE 900 99 EXIT 157 99 EAST MARGINAL WAY CORPORATE PARK FROM SEATTLE- TACOMA AIRPORT 599 TUKWILA FTTR-OJECT SITE FROM KENT & AUBURN DEVELOPMENTAL CENTER 900 N0 SCALE 1 L. -J qY ARP. 2, .03E..= EIES BOEING DEVELOPMENTAL CENTER 9725 EAST MARGINAL WAY SOUTH TUKWILLA, WASHINGTON 98108 AREA MAP BLDG. 21 -02 ADDRESS: 3417 SO. 120TH PLACE TUKWILLA, WA. (EAST MARGINAL WAY CORPORATE PARK) 121 -03 121 -05 •! • • loseSsolzs NO SCALE EAST MARGINAL WAY CORPORATE PARK GENERAL NOTES CONSTRUCTION SET OF DOCUMENTS, REVIEWED AND STAMPED BY CITY OF TUKWILA MUST BE ON SITE DURING CONSTRUCTION. DO NOT PROCEED WITH CONSTRUCTION WITHOUT ABOVE MENTIONED SET OF DOCUMENTS. VERIFY ALL DIMENSIONS PRIOR TO START OF CONSTRUCTION. NOTIFY FACILITY ENGINEERS SHOULD EXISTING CONDITIONS REQUIRED DESIGN REVISIONS. REVISIONS 10 BE APPROVED BY CITY OF TUKWILA PRIOR TO PROCEEDING WITH PROPOSED REVISED WORK. PROJECT CHECKLIST CHECK BOX DD BRIEF PROJECT NARRATIVE REVISE RESTROOMS AND FIXTURE LAYOUTS BO THESE DRAWINGS CONFORM TO THE 1991 U.B.C., U.F.C., U.P.C., AND THE BARRIER FREE CODE AS ADAPTED OR AMENDED BY LOCAL ORDINANCES, AND COMPLIANCE WITH CITY OF TUKWILA ZONING. BD COMPLETE BUILDING FLOOR PLAN SHOWING EXITING SYSTEM, DOORS, CORRIDORS AND PASSAGEWAYS. ENGINEERING CALCULATIONS ( IF APPLICABLE ) ROOMS LABELED PER OCCUPANCY PER U.B.C. TABLE 33 -A. 0 CO BUILDING FLOOR NUMBER ON PRINT FOR AREA OF CONSTRUCTION. NUMBER OF PRINTS REQUIRED FOR PERMIT PACKAGE: O 1. GENERAL PERMIT (SHELL & CORE) 6 SETS OF ENERGY CALCULATIONS 2 SETS OF CIVIL DRAWINGS WITH UTILITIES ? SFTS SOII S REPORTS, STAMPED BY GEOTECHNICAI ENGINEER 2 SETS STRUCTURAL CALCULATIONS 2 SETS PROJECT CONSTRUCTION SPECIFICATIONS 2 SETS TOPOGRAPHICAL SURVEY 2 COPIES OF LEGAL DESCRIPTION 2 SETS OF WORKING DRAWINGS ® 2. TENANT IMPROVEMENTS, 2 COMPLETE SETS O 3. MECHANICAL, 2 COMPLETE SETS O 4. FIRE PROTECTION /SPRINKLERS, 2 COMPLETE SETS L_ _J MS FILE COPY �I' tlr+rr MOSelwwro �w►ot ► ot 1 b of otaw.�.'-_ IedO� ii . lj:b0 Pted c pV cl a �ywlM trector • BY Date Permit No. • -p CODE SUMMARY LAND USE CODE CODE REFERENCES OCCUPANCY GROUP CONSTRUCTION TYPE FLOOR AREA (ACTUAL) BUILDING HEIGHT: STORIES: FIRE PROTECTIONS SEISMIC ZONE FIRE ZONE PARKING PROVIDED PARKING REQUIRED M -HP 1991 UBC • KING COUNTY / TUKWILA WASHINGTON STATE ENERGY CODE WASHINGTON STATE BARRIER FEE CODE ADDITIONS PER CITY OF TUKWILLA B 2 OFFICE, NO CHANGE IN OCCUPANCY V 1HR SPRINKLER BUILDING FOOTPRINT 107,500 SF 26' -5 1/2" FLOOR TO PLATE 1 FULLY AUTOMATIC, WET PIPE THROUGHOUT 3 3 739 725 NOTE: MECHANICAL AND ELECTRICAL PERMITS ARE TO BE SUBMITTED SEPARATLY FROM THIS PACKAGE. SEPARATE PERMIT REQUIRn 17:7: MEC „qr,: :_'.L ►' PWMBiR'� ❑ PIPiVG CITY OF TUKWILA BUILDING DIVISION RENSON BY APPROY(D CAW sW BY AMR0YE0 0A11 UPGRADE ELECTRICAL SERVICE (910905 -01 b. PETERSO 12 -t3 -91 B ein' FACILITIES DEPARTMENT p AUBURN, WA. 98002 p EVERETT, WA. 98201 D KENT, WA. 98031 p PORTLAND, OR. 97220 p RENTON, WA. 98055 • SEATTLE, WA. 98124 ACCEPTABILITY ,NS 01504 AND SY(ar,WTION 11 DRAM BY - OAT( EDDIE P. DUARTE 12 -13-91 scat[, SUBTITLE TITLE SHEET LAST R/NSIW SWIM OAT( SHUT APPROVED BY OEM. OA1E W.E PETERSON 1212_ ca(o n ARCHITECTURAL MASTER BLDG. 21 -0'):" ALL D.0 Al sal No. 910905 -01 ONc No. 21- 0/- Al DRAWING INDEX DRAAING NO. -- c,u r - N17. r 1 1 I -- - - - DRAWING 40. I :;id[ - _ NC;. - i- , t L -.. t- 1i,, I -- - -- -- - -- — - -- - - -- -- - - - -- — -- -- - — — - - - -- — - - — t -- CODE SUMMARY LAND USE CODE CODE REFERENCES OCCUPANCY GROUP CONSTRUCTION TYPE FLOOR AREA (ACTUAL) BUILDING HEIGHT: STORIES: FIRE PROTECTIONS SEISMIC ZONE FIRE ZONE PARKING PROVIDED PARKING REQUIRED M -HP 1991 UBC • KING COUNTY / TUKWILA WASHINGTON STATE ENERGY CODE WASHINGTON STATE BARRIER FEE CODE ADDITIONS PER CITY OF TUKWILLA B 2 OFFICE, NO CHANGE IN OCCUPANCY V 1HR SPRINKLER BUILDING FOOTPRINT 107,500 SF 26' -5 1/2" FLOOR TO PLATE 1 FULLY AUTOMATIC, WET PIPE THROUGHOUT 3 3 739 725 NOTE: MECHANICAL AND ELECTRICAL PERMITS ARE TO BE SUBMITTED SEPARATLY FROM THIS PACKAGE. SEPARATE PERMIT REQUIRn 17:7: MEC „qr,: :_'.L ►' PWMBiR'� ❑ PIPiVG CITY OF TUKWILA BUILDING DIVISION RENSON BY APPROY(D CAW sW BY AMR0YE0 0A11 UPGRADE ELECTRICAL SERVICE (910905 -01 b. PETERSO 12 -t3 -91 B ein' FACILITIES DEPARTMENT p AUBURN, WA. 98002 p EVERETT, WA. 98201 D KENT, WA. 98031 p PORTLAND, OR. 97220 p RENTON, WA. 98055 • SEATTLE, WA. 98124 ACCEPTABILITY ,NS 01504 AND SY(ar,WTION 11 DRAM BY - OAT( EDDIE P. DUARTE 12 -13-91 scat[, SUBTITLE TITLE SHEET LAST R/NSIW SWIM OAT( SHUT APPROVED BY OEM. OA1E W.E PETERSON 1212_ ca(o n ARCHITECTURAL MASTER BLDG. 21 -0'):" ALL D.0 Al sal No. 910905 -01 ONc No. 21- 0/- Al 13q olgs ADD COMPOSITE ROOF PLAN REVISED DRAWINGS ISSUED FOR PERMIT i CONSTUCTION RESTROOMS FOR PERMIT 4 CONSt memo ammo , : :i anc 4.22.94 4.26.94 5.4.94 5.9.94 INDEX OF DRAWINGS INDEX OF DRAWINGS INCLUDE IN I SET SHEET NO. , SHEET NO.. DRAWING TITLE REV DATE DRAWING NO. IO MECHANICAL ARCHITECTURAL O 121- 002 -4301 M-1 21 -02 -AO C _AO COVER SHEET B 5.4.94 O 21 -02 -A1 _ 04.27.94 Al KEY SHEET A 5.4.94 • 21 -02 -A2 O A2 INDEX OF DRAWINGS D 5.9.94 O 21- 02 -A3R 121 - 002 -4003 A3R COMPOSITE FLOOR PLAN - REMOVAL C 5.4.94 0 21- -02 -A4 M-2 s A4 COMPOSITE FLOOR PLAN C 5.4.94 O 21 -02 -1410 PLUMBING ISOMETRIC DIAGRAM 1A10 PARTIAL FLOOR PLAN C 5.4.94 0 21-02 -1411 05.9.94 4 IA11 PARTIAL FLOOR PLAN C 5.4.94 0 21- 02 -1Al2 04.21.94 1Al2 PARTIAL FLOOR PLAN C 5.4.94 0 21-02 -1413 O 1A13 PARTIAL FLOOR PLAN C 5.4.94 • 21- 02 -A200 21- 02 -1E12 A200 , RESTROOM PLANS a DETAILS ORIG 5.9.94 • 21- 02 -A201 1E13 A201 RESTROOM SECTIONS ORIG 5.9.94 O 21- 02 -A280 208Y/120V POWER A280 COMPOSITE ROOF PLAN 8 5.4.94 0 21- 02 -A500 H A500 DETAILS B 5.4.94 208Y/120V POWER D 04.23.94 0 21- 02 -1E33 1E33 208Y/120V POWER J 04.23.94 0 21- 02 -1E51 1E51 480Y/277V POWER ORIG 04.23.94 0 21- 02 -1E52 1E52 480Y/277V POWER ORIG 04.23.94 0 21- 02 -1E53 1E53 480Y/277V POWER J 04.27.94 0 21- 02 -E500 E500 DETAILS ORIG 04.23.94 0 21- 02 -E501 E501 DETAILS ORIG 04.23.94 CIVIL /STRUCTURAL O 21 -02 -S2 S2 GENERAL STRUCTURAL NOTES C 5.4.94 0, 21 -02 -5160 S160 PARTIAL ROOF FRAMING PLAN C 4 5.4.94 0 21 -02 -5161 S161 PARTIAL ROOF FRAMING PLAN C 5.4.94 0 21- 02 -S162 S162 PARTIAL ROOF FRAMING PLAN C 5.4.94 0 21- 02 -S163 S163 PARTIAL ROOF FRAMING PLAN C 5.4.94 0 21- 02 -S500 S500 MISCELLANEOUS DETAILS B 5.4.94 0 21- 02 -S501 S501 STORAGE RACK AND SHELVING CONFIGURATIONS B 5.4.94 13q olgs ADD COMPOSITE ROOF PLAN REVISED DRAWINGS ISSUED FOR PERMIT i CONSTUCTION RESTROOMS FOR PERMIT 4 CONSt memo ammo , : :i anc 4.22.94 4.26.94 5.4.94 5.9.94 ISSUE LEGEND NOT YET ISSUED 0 PREVIOUSLY ISSUED, NOT IN THIS ISSUE U THIS ISSUE 0 PREVIOUS PROJECT, NOT YET ISSUED FOR CURRENT PROJECT NOT REQUIRED FOR CURRENT PROJECT NFC NOT FOR CONSTRUCTION FRO FOR REFERENCE ONLY ORIG ORIGINAL ISSUE FOR CONSTRUCTION OR FOR PERMIT A DRAWING REVISION - SEE SPECIFIC DRAWING FOR NATURE OF REVISION arrIFILA NAY 161994 PERM p FAS E GISTERED ACCEPTABILITY WIC Arm iteoZto ArM0110 IN O n. OAR EN,/ IEN Il 04.1294 T INDEX OF DRAWINGS L*t %MUON 10•1443C II•INIERS BUILDING 214)2 ARCHITECTURAL MASTER COL o :. A2 DCA -94052 an N°' 21 -02 -A2 mat 5.9.94 or INDEX OF DRAWINGS INCLUDE IN SET DRAWING NO. SHEET NO. DRAWING TITLE REV DATE MECHANICAL , O 121- 002 -4301 M-1 4 FIRE PROTECTION C 04.27.94 O 121- 002 -4302 4 M-1 FIRE PROTECTION B _ 04.27.94 O 121 - 002 -4002 M-1 PIPING PLAN 8 04.27.94 O 121 - 002 -4004 M-1 PIPING PLAN F 04.27.94 • 121 - 002 -4003 M-2R PIPING — ISOMETRIC DIAGRAM ORIG 05.9.94 , • 121- 002 -4003 M-2 PIPING — ISOMETRIC DIAGRAM 8 05.9.94 _ 05.9.94 0 121- 002 -4503 , M-2R PLUMBING ISOMETRIC DIAGRAM ORIG,' • 121- 002 -4503 M-2 PLUMBING ISOMETRIC DIAGRAM B 05.9.94 O 21- 02 -M500 M500 DETAILS A 04.27.94 04.21.94 0 21- 02 -1E10 1E10 LIGHTING E 04.27.94 O 21- 02 -1E11 1E11 LIGHTING D 04.27.94 0 21- 02 -1E12 1E12 LIGHTING H 04.27.94 0 21- 02 -1E13 1E13 LIGHTING H 04.27.94 0 21- 02 -1E30 1E30 208Y/120V POWER D 04.23.94 0 21- 02 -1E31 1E31 208Y/120V POWER H 04.27.94 0 21- 02 -1E32 1E32 208Y/120V POWER D 04.23.94 0 21- 02 -1E33 1E33 208Y/120V POWER J 04.23.94 0 21- 02 -1E51 1E51 480Y/277V POWER ORIG 04.23.94 0 21- 02 -1E52 1E52 480Y/277V POWER ORIG 04.23.94 0 21- 02 -1E53 1E53 480Y/277V POWER J 04.27.94 0 21- 02 -E500 E500 DETAILS ORIG 04.23.94 0 21- 02 -E501 E501 DETAILS ORIG 04.23.94 ISSUE LEGEND NOT YET ISSUED 0 PREVIOUSLY ISSUED, NOT IN THIS ISSUE U THIS ISSUE 0 PREVIOUS PROJECT, NOT YET ISSUED FOR CURRENT PROJECT NOT REQUIRED FOR CURRENT PROJECT NFC NOT FOR CONSTRUCTION FRO FOR REFERENCE ONLY ORIG ORIGINAL ISSUE FOR CONSTRUCTION OR FOR PERMIT A DRAWING REVISION - SEE SPECIFIC DRAWING FOR NATURE OF REVISION arrIFILA NAY 161994 PERM p FAS E GISTERED ACCEPTABILITY WIC Arm iteoZto ArM0110 IN O n. OAR EN,/ IEN Il 04.1294 T INDEX OF DRAWINGS L*t %MUON 10•1443C II•INIERS BUILDING 214)2 ARCHITECTURAL MASTER COL o :. A2 DCA -94052 an N°' 21 -02 -A2 mat 5.9.94 or INDEX OF DRAWINGS INCLUDE IN SET DRAWING NO. SHEET N0. DRAWING TITLE REV DATE ELECTRICAL O. 121- 002 -2001 E -10R LIGHTING- REMOVAL E 04.24.94 0 121- 002 -2001 E -11R LIGHTING - REMOVAL D 04.24.94 0 121 -002 -2001 E -12R LIGHTING - REMOVAL H 04.24.94 0 121 -002 -2001 E -13R LIGHTING- REMOVAL H 04.24.94 0 121- 002 -2001 E -30R 120/208V POWER - REMOVAL D 04.24.94 0 121- 002 -2001 E -31R 120/208V POWER - REMOVAL H 04.24.94 0 121- 002 -2001 E -33R 120/208V POWER - REMOVAL J 04.24.94 0 121 -002 -2001 E -53R 277/480V POWER - REMOVAL J 04.24.94 0 21 -02 -E6 E6 ADT 1 TELEPHONE ORIG 04.21.94 0 21- 02 -1E10 1E10 LIGHTING E 04.27.94 O 21- 02 -1E11 1E11 LIGHTING D 04.27.94 0 21- 02 -1E12 1E12 LIGHTING H 04.27.94 0 21- 02 -1E13 1E13 LIGHTING H 04.27.94 0 21- 02 -1E30 1E30 208Y/120V POWER D 04.23.94 0 21- 02 -1E31 1E31 208Y/120V POWER H 04.27.94 0 21- 02 -1E32 1E32 208Y/120V POWER D 04.23.94 0 21- 02 -1E33 1E33 208Y/120V POWER J 04.23.94 0 21- 02 -1E51 1E51 480Y/277V POWER ORIG 04.23.94 0 21- 02 -1E52 1E52 480Y/277V POWER ORIG 04.23.94 0 21- 02 -1E53 1E53 480Y/277V POWER J 04.27.94 0 21- 02 -E500 E500 DETAILS ORIG 04.23.94 0 21- 02 -E501 E501 DETAILS ORIG 04.23.94 ISSUE LEGEND NOT YET ISSUED 0 PREVIOUSLY ISSUED, NOT IN THIS ISSUE U THIS ISSUE 0 PREVIOUS PROJECT, NOT YET ISSUED FOR CURRENT PROJECT NOT REQUIRED FOR CURRENT PROJECT NFC NOT FOR CONSTRUCTION FRO FOR REFERENCE ONLY ORIG ORIGINAL ISSUE FOR CONSTRUCTION OR FOR PERMIT A DRAWING REVISION - SEE SPECIFIC DRAWING FOR NATURE OF REVISION arrIFILA NAY 161994 PERM p FAS E GISTERED ACCEPTABILITY WIC Arm iteoZto ArM0110 IN O n. OAR EN,/ IEN Il 04.1294 T INDEX OF DRAWINGS L*t %MUON 10•1443C II•INIERS BUILDING 214)2 ARCHITECTURAL MASTER COL o :. A2 DCA -94052 an N°' 21 -02 -A2 mat 5.9.94 or REMOVE FLOOR TILE AT AREAS OF NEW RESTROOM EXISTING HEADER 7'-6' 1 L REMOVE DOOR FRAME I ,,= REMOVE EXISTING DOORS `, - "•,' AND FRAMES AND SAVV FOR RUSE 4' -O" n • REMOVE EXISTING DRINKING FOUNTAIN WOMEN rt-i a REMOVE WALLS TO 7' AS SHOWN J r ~" (41 1 " MEN moinrUJI dr DEMOLITION PLAN SCALE: 1/4- EMWE EXISTING PAPER OWEL DISPENSERS AND SOAP DISPENSER AND SAVE FOR REUSE EXISTING LAVATORIES TO BE RELOCATED, SEE MECH. REMOVE EXISTING MIRROR AND SAVE FOR REUSE REMWE EXISTING FEMENINE NAPKIN DISPENSER AND SAVE FOR REUSE EXISTING TOILET PARTITIONS TO BE REMOVED REMOVE EXISTING GRAB BARS NOV .t /5 PAPER TOWEL DISPENSERS WAINSCOTTING WITH METAL TRIM, TYPICAL AT ALL RESTROOM WALLS SHEET VINYL TURNED UP WALL TO FORM BASE NORTH ELEVATION SCALE: 1/4" = NORTH ELEVATION SCALE: 1/4" = 1' -0- TSCD TPD FND OMEN ONLY, COAT 1400K N`` • n o L A200 A200 PAPER TOWEL DISPENSERS URINAL SCREEN 1--tip. I •n q TYPICAL TOILET COMPARTMENT 1/4 ".1. -0 - A200 A200 sirs 144 U A200 A201 5'- 1 1/4 ro.S. •' /H/N////// (\SIM. A200 I 901 A200 A�01 �I ti 4' -0" ~CLrAR 0 7' -4 OS.T 4' -O" FCLEAR es i NEW HEADER L_ 34w1?.ND © FND WOMEN EXIST. FLOOR TILE TO REMAIN AT ENTRY XISTING HEADER a EXIST. N EXIST. EW EXIST. NEW HEADER EXIST. EXIST. PLAN SCALE: 1/4" = 1' -0' Imo- 5' -0' SOAP DISP.j EAST ELEVATION SCALE: 1 /e = 1' -d' I ml • - - N O N I 1 =a A200 A200 EXIST MIRR OIf TPD PTD n ', 5 7 II .1 EAST ELEVATION SCALE: 1/4" = 1' -0' fir\ A200 A200 i MEN i a NEW SHEET VINYL AT RESTROOMS EXIST. 0 WITH INTEGRAL TILE TO 6" BASE AT CORRID EW WALLS TO BE 3 1/2" ETAL STUDS WITH 5/r GWB AT BOTH SIDES. GWB TO WATER RESISTANT AT RESTROOM SIDE REPLACE DAMAGED WAINSCOTTING AND PROVIDE NEW AT ALL RESTROOM WALLS. WAINSCOTTING TO HAVE METAL TRIM TO MATCH EXISTING NEW FLOOR SUPPORTED TOILET PARTITIONS AT MEN AND WOMEN NEW GRAB BARS AT MEN AND WOMEN a 5' -0' FND SOUTH ELEVATION SCALE: 1/4' = 1' -0" A200 AZOO SOUTH ELEVATION (Pig O�O0 SCAE: 1/4" = 1' -D i gis r MIN 3' -0. ' TYPICAL HANDICAPPED TOILET 1/4 "a1' -0" PAPER TOWEL PAPER TOWEL FEM NAPKIN DISPENSER DISPENSER DISPENSER (PTD) (TPD)HANDICAP CI N FEM NAPKIN 0ISPOSAL N1 TOILET PAPER DISPENSER TYPICAL FIXTURE HFIGHTS 1/4 -Q1 /-o- sin 10 (i'D SEAT COVER DISPENSER (SCD) A2 A2 RELOCATED SRINKLER HEADS PROVIDE DOUBLE STUDS AT EACH SIDE OF HEADER, TYPICAL NEW HEADER TO MATCH EXISTING EXISTING HEADER NEW HEADER TO MATCH EXISTING NEW CEILING REFLECTED CEILING PLAN SCALE: 1/4' = 1' -0" TPD EXISTING MIRROR PTD 2.-3- WEST ELEVATION SCALE: 1/4" = 1' -0' 2' -3' 4 1 0 A200AA200 U HC WEST ELEVATION SCALE: 1/4" = 1' -0' 1'-- MIN. syF I 46:1 - URINAL lit o —' 2 C N N� N GRAB BAR DRINKING FOUNTAIN (DF) A200 A200 tWRAP ALL DRAINS PER ACCESIBI.E REQUIREMENTS N A NAY III 694 POINT GMT LAV NOTE: PROVIDE BLOCKING FOR ALL SURFACE MOUNTED TOILET ACCESSORIES - TYPICAL ALL TOILET ROOMS UNLESS NOTED OTHERWISE FA /OsPws ACCEPTABILITY MS CE I ANC It SIECMWATION 5 now N DEPT. ut Nn''' RESTROOM PLANS AND ELEVATIONS LAST ItMSKIN NBC INSINIRNS OATS BUILDING 21 -02 ARCHITECTURAL MASTER COL c- D/11 -11 D.0 A200 N. DC -94052 T 00. 21- 02 -A200 a - ' • • • i0 11 NEW 6" METAL JOIST CEILING FRAMING TO MATCH EXISTING W/ 5/8" GWB AT TOP AND BOTTOM EXISTING CEILING FRAMING NEW 3 1/2" HEADER AT SAME HEIGHT AND LOCATION AS EXIST. PROVIDE DOUBLE STUDS AT EACH SIDE OF HEADER NEW 3 1/2" STUD WALL WITH 5/8" GWB AT EACH SIDE. NOTE: ALL GWB AT RESTROOM SIDE OF NEW WALLS TO BE WATER RESISTANT EXISTING DOOR AND FRAME IN NEW WALL r- EDGE OF WALL BEYOND SECTION SCALE: 3/4" = 1� A200 A201 0 SECTION SCALE: 3/4" = 1' -0" -015 �1 A200 A201 EXISTING CEILING FRAMING PROVIDE BLOCKING FOR NEW WALL AT EXISTING CEILING JOISTS EXISTING HEADER NEW 3 1/2" HEADER AT SAME HEIGHT AND LOCATION AS EXIST. PROVIDE DOUBLE STUDS AT EACH SIDE OF HEADER NOTE: ALL GWB AT RESTROOM SIDE OF NEW WALLS TO BE WATER RESISTANT METAL EDGE TRIM WAINSCOT PANELING NEW 3 1/2" STUD WALL WITH 5/8" GWB AT EACH SIDE. 6" FORMED BASE 6'I iosas FACILITIES DEPARTMENT T 1661 REGISTERED ARCHITECT ACCEPTABILITY 'A14 6 UWP p D A IN o. � � amtirtuTstA NAY 16199k Mir COMM RESTROOM SECTIONS BUILDING 21 -02 ARCHITECTURAL MASTER COL D.c A ??RovED juf3T3911 IASI IIEMlION " A201 1os "o' DCA -94052 T�iia'ir3 )Q kii. E sc NSINIEINS wn or 21- 02 -A201 c g • R99 /05.09.94/08:37