Loading...
HomeMy WebLinkAboutPermit D02-018 - HIGH FIVE SPORTSWEARD02-018 High Five Sportswear 18200 Segale Pk Dr. B Parcel No.: 3523049119 Address: 18200 SEGALE PARK DR B TUKW Suite No: Tenant: Name: HIGH FIVE SPORTSWEAR Address: 18200 SEGALE PARK DR B, TUKWILA, WA Owner: Name: LA PIANTA LTD PARTNERSHIP Address: PO BOX 88050, TUKWILA WA Contact Person: Name: MIKE SORENSON Address: 1100 SW 7 ST, RENTON, WA Contractor: Name: NORTH WEST HANDLING SYSTEMS INC Address: 1100 S.W. 7TH STEET, RENTON, WA Contractor License No: NORTHWH275JF DESCRIPTION OF WORK: ANCHOR STORAGE RACKING Value of Construction: $0.00 Fees Collected: $141.86 Type of Fire Protection: SPRINKLERS Uniform Building Code Edition: 1997 Type of Construction: Occupancy per UBC: 0025 Public Works Activities: Curb Cut/Access /Sidewalk/CSS: N Fire Loop Hydrant: N Flood Control Zone: N Hauling: N Land Altering: N Landscape Irrigation: N Moving Oversize Load: N Sanitary Side Sewer: N Sewer Main Extension: N Storm Drainage: N Street Use: N Water Main Extension: N Water Meter: Channelization / Striping: doc: Devperm City of iukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 DEVELOPMENT PERMIT D02 -018 Number: 0 Start Time: Volumes: Cut Start Time: Private: N Private: N ** Continued Next Page ** Permit Number: D02 -018 Issue Date: 03/12/2002 Permit Expires On: 09/08/2002 Phone: (206) 575 -3200 Phone: 206 - 910 -2704 Phone: 206 255 -0500 Expiration Date: 10/01/2002 0 c.y. Size (Inches): 0 End Time: Fill 0 c.y. End Time: Public: N Public: N Printed: 03 -12 -2002 z a Wi re W WD 00 co J LL W u- = co I z h. F- 0 z W ui • Oi O N • 1- W W u. I— — 111 z U = O h- z City of Tukwila Departn :ent of Comniu city Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Permit Center Authorized Signature: kalt14,6 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the erf. - - . ork. I am authorized to sign and obtain this development permit. Signature: i Date: <..? �-- r A e , Print Name: l C XL J0V Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: Devperm D02 -018 Printed: 03 -12 -2002 z -z. re 6 -IU 0 W= � w O 1 Q: D mo z H: I— O' z I— : uj O N 0 I-- I V LL z ' O F- ' z City of Tukwila PERMIT CONDITIONS Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 3523049119 Permit Number: D02-018 Address: 18200 SEGALE PARK DR B TUKW Status: ISSUED Suite No: Applied Date: 01/22/2002 Tenant: HIGH FIVE SPORTSWEAR Issue Date: 03/12/2002 1: ** *BUILDING DEPARTMENT * ** 2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 3: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any construction. These documents are to be maintained and available until final inspection approval is granted. 4: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 5: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be con- strued to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. 6: ** *FIRE DEPARTMENT CONDITIONS * ** 7: Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5) 8: The total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 3000 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 10B:C) dry chemical type. Travel distance to ally fire extinguisher must be 75' or less. (NFPA 10, 3- 1.1) 9: Maintain fire extinguisher coverage throughout. 10: The total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 1,000 sq. ft. of area. The extinguisher should be of the "all purpose" 4A 40 B:C dry chemical type. The travel distance to any extinguisher must be 50' or less. (NFPA 10, 3- 1.1) 11: No point in an unsprinklered building may be more than 200 feet from an exit, measured along the path of travel. (UBC 1004.2.5.2.1) 12: Exit doors shall swing in the direction of exit travel when serving any hazardous area or when serving an occupant load of 50 or more. (UBC 1003.3.1.5) 13: Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 1207,3) 14: When two or more exits from a story are required, exit signs shall be installed at the required exits and where otherwise necessary to clearly indicate the direction of egress. (UBC 1003.2.8.2) 15: Exit doors shall be maintained in accordance with Section 1207. Exit doors shall be maintained in an operable conditino. Doors installed as part of required fire assemblies shall be maintained in accordance with Section 1112.2. (UFC 1207.1) 16: These plans were reviewed by Inspector 510. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575- 4407. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances doc: Conditions D02 -018 Printed: 03 -12 -2002 z � UO J H � W gQ .co I w z = t— H O z w O 0 I-- W W. U. b- . z • UN z governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: e Print Name: i " (l cA.ajt,f c ,�'UO!?..S6i• - � doc: Conditions City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 D02 -018 Printed: 03 -12 -2002 Project Name/Tenant: Existing use: ❑ Retail ❑ Restaurant C3 Multi-family RI Warehouse Hospital El Church aManufacturin ❑ Motel /Hotel ❑ Office ❑ School /College /University ❑ Other Proposed use: El Retail ❑ Restaurant ❑ Multi- family `Warehouse ❑Hospital ❑ Church Manufacturing ❑ Motel /Hotel ❑ Office ❑ School /College /Universiitptty�y,, Value of Construction: r , 6 Will there be rack storage? 4 yes ❑ no Site Address: Building Square Feet: Cr; o i / S existing �r ✓� City State/ ip: Tax Parcel Number: Phone: / t4 / tic-v1 (C( Property Oy -ner: Y Street Addre ; City State /Zip: Fax #: Contractor: / _, Street Address: /l e) 0 S l r?‹ Architect: Phone: , Street Address: City State /Zip: Fax #: Engineer: Phone: Street Address: City State /Zip: Fax #: Contact Person: fr- /`� Description of work to be doh_ .... 0,0"-400" 5 'r& /G. 64 Existing use: ❑ Retail ❑ Restaurant C3 Multi-family RI Warehouse Hospital El Church aManufacturin ❑ Motel /Hotel ❑ Office ❑ School /College /University ❑ Other Proposed use: El Retail ❑ Restaurant ❑ Multi- family `Warehouse ❑Hospital ❑ Church Manufacturing ❑ Motel /Hotel ❑ Office ❑ School /College /Universiitptty�y,,"" Cl Other Will there be a change of use? ❑ yes 1tcno If yes, extent of change: (Attach additional sheet if necessary) Will there be rack storage? 4 yes ❑ no Existing fire protection featur'sprinklers ❑ automatic fire alarm El none El other (specify) Building Square Feet: Cr; o i / S existing Area of Construction: (sq. ft.) c" Will there be storage of flammable /combustible hazardous Attach list of materials and storage location on separate, 8 material in the building? ❑ yes El no 1/2 X 11 paper indicating quantities & Material Safety Data Sheets CITY OF rut zWI LA Permit Center 6300 Southcenter Blvd., Suite 100, Tukwila, WA 98188 (206) 431 -3670 Commercial / Multi - Family Tenant Improvement / Alteration Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. El Channelization /Striping 71 Curb cut /Access /Sidewalk ❑ Flood Control Zone ❑ Hauling ❑ Fire Loop /Hydrant (main to vault) #: Size(s): ❑ Land Altering 0 Cut cubic yds. 0 Fill cubic yds. ❑ Landscape Irrigation ❑ Sanitary Side Sewer #: ❑ Sewer Main Extension 0 Private 0 Public El Storm Drainage 1.1 Street Use ❑ Water Main Extension 0 Private 0 Public ❑ Water Meter /Exempt #: Size(s): 0 Deduct 0 Water Only El Water Meter /Permanent # Size(s): C3 Water Meter Temp # Size(s): Est. quantity: gal Schedule: El Miscellaneous Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit Is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date applic tion acce ted: • LEASE SIGN BACK OF APPLICATION FORM CTPERMIT.DOC 1/29/97 APPLICANT: REQUEST. FOR PUBLIC WORKS SITE/CIVIL PLAN REVIEW OF THEFOLLOWING : :. :. (Additional reviews ma be determined by the Public Works Department) Date application expires: FOR STAFF USE ONLY Project Number: Permit Number: DO BUILDING OWNER 0: A - ■ •IZED AGENT: Signature: / Date: 4„ /) Print name: / 0 tzi z- J . vr r7 Ig : '/d 76 .• ,;?c? O f 4(-K Address ( / U S w -PI. /ii-i-, 9 c) t -- City /State /Zip ALL COMMERCIAL/MULTI-FAISY TENANT IMPROVEMENT/ALT-NATION PERMIT APPLICATIONS MU BE SUBMITTED WITH THE FOLLING: ILL DRAWINGS,TO BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT, S" R,UCi1JR L ENGINEER OR CIVIL ENGINEER ➢ ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN ➢ BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A SUBMITTED ❑ ❑ Complete Legal Description ❑ ❑ Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures ` (Form H -13). Business Declaration required (Form H -10). Four (4) sets of working drawings (five(5) sets for structural work), which include : ❑ ❑ Site Plan (including existing fire hydrant location(s) 1. North arrow and scale 2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements 3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions 4. Location of driveways, parking, loading & service areas 5. Recycle collection location and area calculations (change of use only) 6. Location and screening of outdoor storage (change of use only) 7. Limits of clearing /grading with existing and proposed topography at 2' intervals extending 5' beyond property's boundaries 8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of use only) z 9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of 11 those, identify by size and species which are to be removed and saved w rt 10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change J of use only) _J U O 11. Location and gross floor area of existing structure with dimensions and setb ck rn 0 12. Lowest finished floor elevation (if in flood control zone) u) _ 13. See Public Works Checklist for detailed civil /site plan information r ?quired fo Public Works Review (Form H- 1— 9). w0 ❑ ❑ Floor plan: show location of tenant space with proposed use of each room labeled 2 CI ❑ I Q Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of g 5 any hazardous materials; dimensions of proposed tenant space. = c5 I--w ❑ ❑ Vicinity Map showing location of site z 1=0 i- ❑ ❑ Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack w h- layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of ? o rack. Structural calculations are required for rack storage eight feet and over. U ❑ ❑ Indicate proposed construction of tenant space or addition and walls being demolished O(22 0 t— w w ❑ ❑ Construction details i c ❑ ❑ Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of O z water supply to sprinkler vault with documentation from contractor stating supply line will meet or U cn exceed sprinkler system design criteria as identified by the Fire Department. F- _ O 10 Washington State Non - Residential Energy Code Data shall be noted on the construction drawings. Z ❑ ❑ SEPA Checklist - if intensification of use (check with Planning Department for thresholds). ❑ ❑ Attach plans, reports or other documentation required to comply with Sentitive Area Ordinance or other land use or SEPA decisions. ❑ ❑ Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County Department of Public Health prior to submitting for building permit application. The Department of Public Health is located at 201 Smith Tower, Seattle, WA or call (206) 296 -4787. (Form H -5) ❑ ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no contractor has been selected at time of application a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. CTPERMIT.DOC 1/29/97 RAKV7VVIOWSfX !a;Fr +n4+NisgWXi7n'Pr.*vv w.. re. n +., r, n•.... n. wn,..,..,..,,.,...•. ........ ........ .M.....,_ o.-., f,. rrwirc; �». w�..,„. �vr.. x., We... ..�.,,�.:,wor- .n,er�nnu•rftSM'� Pm. g" � • t�������.�.�.Lr+.r • > r a, MOM Parcel No.: Address: Suite No: Applicant: Receipt No.: Initials: User ID: Payee: KAS 1684 TRANSACTION LIST: doc: Receipt HIGH FIVE SPORTSWEAR R020000333 MICHAEL J. SORENSON Amount Payment Check ACCOUNT ITEM LIST: Current Pmts 4234 BUILDING - NONRES STATE BUILDING SURCHARGE City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 3523049119 18200 SEGALE PARK DR B TUKW Type Description RECEIPT Method Description 000/322.100 000/386.904 Permit Number: Status: Applied Date: Issue Date: Payment Amount: 87.75 Payment Date: 03/12/2002 08:38 AM Balance: $0.00 87.75 Account Code 83.25 4.50 Total: 87.75 D02 -018 APPROVED 01/22/2002 4726 03/13 1719 TOTAL 67.75 Printed: 03 -12 -2002 z a • Z ' w. r e = J U U O w 0 � ▪ F- • u. w O • }}: u.. Q = H =; Z H- O Z1- U.1 uj 2 p; U O N • H w F- r- U. 0 .. Z' U N` O � z RECEIPT 1 Z` re W . Parcel No.: 3523049119 Permit Number: D02 -018 U O ' Address: 18200 SEGALE PARK DR B TUKW Status: PENDING co ca . Suite No: Applied Date: 01/22/2002 W = Applicant: HIGH FIVE SPORTSWEAR Issue Date: y u WO Receipt No.: R020000078 Payment Amount: 54.11 g Q . Initials: KAS Payment Date: 01/22/2002 03:38 PM _ User ID: 1684 Balance: $83.25 I— IL Z 2 I— O Z I—. Payee: MICHAEL J. SORENSON lli W Mp . 0 O N, TRANSACTION LIST: iC3 H Type Method Description = W Amount F F F.. t Payment Check 4214 54.11 Z . 0 D. O Z ACCOUNT ITEM LIST: doc: Receipt Current Pmts PLAN CHECK - NONRES City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Description Account Code 000/345.830 54.11 Total: 54.11 2879 01./23 971.6 TOTAL 54-11 Printed: 01 -22 -2002 diteattaS 1 Proj c F('it-f) L-ura 4b, ,TYPe of lnspecti n: Add eis: ii z Date called: Special instructiogt: . bate wanted: l 2 p9 Reque Ir iii I p Plene. p‘ Ala, qjti -.)704 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 Approved per applicable codes. Corrections required prior to approval. COMMENTS: ivvvi...azzpA e tor:. r\. $17.00 REINSPECTION FEE ( 63O0 Southcenter Blvd., Su . . . INSPECTION RECORD Retain a copy with permit •.( 60 - al PERMIT NO. -vv' A fA5 (206)431-3670 Date: Date: QUIRED. Prior t4 inspection, fee must be paid e 100. Call to sch dule reinspection. Receipt No: Date: Special instructions: Date wanted: i a.m. Requester: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 (206)431-3.7 Approved per applicable codes. [ Corrections required prior to approval. " COMMENTS: INSPECTION RECORD , Retain a copy with permit PERMIT NO. $47.00 REINSPE9kON FEE REQUIdElj. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: COMMENTS: -.. L". Requuees�ter: INSPECTION RECORD Retain a copy with permit INSPECTION NO. 'CITY OF TUKWILA BUILDING DIVISION Southcenter Blvd, #100, Tukwila, WA 98188 PERMIT NO. (206)431 -3670 pTdtle Corrections required prior to approval. Date % / �� $47.00 REINSPECTIO at 6300 Southcenter BI Receipt No: FEE REQUIRED. V rior to inspection, fee must be paid d., Suite 100. Call to schedule reinspection. Date: aec manager john more and mike thorenson nw handlink ] BY G. OHANIAN DATE 1 -18 -02 SUBJECT STRUCTURAL CALCULATIONS OF STORAGE RACKS FOR: HIGH FIVE SPORTSWEAR 18200 SEGALE PARK DRIVE SEATTLE, WA. PER UBC 1997 EDITION STORAGE RACKS CAPACITY: 2000 # / LEVEL CALCS. 1 THRU 5 DRAWINGS: RD 6486 F DESIGN & ENGINEERI ; CO. 3786 LA CRESCENTA AVE., SUITE 204 GLENDALE, CA. 91208 TEL:(818)957 -2980 FAX:(818)957 -8603 SHEET NO. 1 JOB NO. RD -6486 CITY OF TUKWILA, APPROVED FED 2 6 2002 1 ;volt.0 t th4LOTi.1O DIVi CIO N EXPIRES 1 2. 2_‘—e53 Doo 1& CIT ROFETUKW JAN 22 PERMIT CENTER BY G. OHANIAN DATE 1 -18 -02 SUBJECT 120" 144" 96" 108" 144" 108" TYPE "A" RACK R K DESIGN & ENGINEERI CO. TYPE "C" RACK 3786 LA CRESCENTA AVE., SUITE 204 GLENDALE, CA. 91208 TEL:(818)957 -2980 FAX:(818)957 -8603 96" 144" 120" 106" i TYPE "B" RACK TYPE "D" RACK SHEET NO. 2 JOB NO, RD -6486 • BY G. OHANIAN DATE 1 -18 -02 SUBJECT 144 ", 120 ", 106" & 93" LONG 2 .3/4" 108" & 102" LONG SEISMIC DESIGN V= 2.5xCax x W Rx 1.4 WORKING STRESS 1 =1 R =5.6 R =4.4 Ca =.36 W= D.L. +L.L. LOAD PER COLUMN P= 3x2 K -3 K 2 W =.1 + 3 =3.1 K D.L. L.L. V = 2.5x.36x3.1 — . LONGIT. 5.6x 1.4 V = 2.5x.57x1.3 = .45 K TRANS, 4.4x1.4 RACTh DESIGN & ENGINEERING 3786 LA CRESCENTA AVE., SUITE 204 GLENDALE, CA. 91208 TEL:(818)957 -2980 FAX:(818)957 -8603 I x =2 S =.9 F Y= 50 KSI. I =1.2 S =.7 F 50 KSI. Y- 102" LONG UBC 1997 SEC. 2222 LONGIT. DIR. (MOM. CONN.) TRANSV. DIR. (BRACED) 485 BEAM 2000 # /LEVEL 1000 # /BEAM I =.8 S =.5 F 50 KSI. Y LONGIT. SEISMIC CO M= 144 "x1 K = 18 "K 8 "K S 30 = .6 <.9 A = 5xWxL = 7 .. < 144 = .8" 384xI xE 180 282 BEAM M= 102 "x1 = 13 "K 8 "K SR= 13 =.4 30 A = 5xWxL = +• < 102 = .56" 384x1 xE 180 SHEET NO. 3 JOB NO. RD - 6486 BY G. OHANIAN DATE 1 -18 -02 SUBJECT COLUMN ANALYSIS COMBIN _ED STRESS RATIO P + Max = 21 + 6.2 = .7 <1.33 o BASE PLATE ANCH. TENSION = 0 ANCHOR SHEAR = .45 K (1) -3/8 "93 WEDGE TYPE ANCHOR ICBO #4627, OR #1372. (NO INSPECTION REQ'D) DESIGNED FOR 1/2 STRESS MOMENT AT BEAM CONNECTION M1 = 6.2 = 5.4 "K USE 2 PIN CONNECTOR ALL LEVELS TYP. 2 PIN CONNECTOR Ma = 3 K 4 , , 1 = 16 "K CONN. RA : DESIGN & ENGINEERIN CO. N 3786 LA CRESCENTA AVE., SUITE 204 GLENDALE, CA. 91208 TEL:(818)957 -2980 FAX:(818)957 -8603 SHEET NO. 4 JOB NO. RD -6486 7/16 RIVET ASTM A354 -79 3 "x3 "x1/8" BASE PLATE KSI 7/16"93 RIVET A = .095 Fy = 79 KSI Va = .095x79x.4 = 3.0 K TYP TH'K =3/16" • By G. OHANIAN DATE 1 -18 -02 SUBJECT TRANSVERSE SEISMIC (OVERTURNING) "K M OT = . 45 K x2 x96"x.5x1.15 = 50 MR = 3.1 x24" = 74 "K NO UPLIFT LOAD TO DIAGONAL P = .45 x 7 2 = 1.2 COL. 60 F Y= 50 KSI A =.31 r =.48 Q =.74 L= 72" COL. CHECK WELDS 1/8" WELD 1.2" LONG EACH SIDE (2.4" TOTAL) 2.4x.125x.707x70x.3 = 4.2 K CHECK SLAB 3100 F = 6.7 P =2.1 RAC DESIGN & ENGINEERINi'CO. 3786 LA CRESCENTA AVE., SUITE 204 GLENDALE, CA. 91208 TEL:(818)957 -2980 FAX:(818)957 -8603 KSI 6" CONCRETE SLAB 2000 PSI. CONC. 1000 PSF. SOIL 3100 =31 1000 S= 12x6 2 =72 6 SEC. 8 -@ 3.1x144=446.4 735 = 10 < 1.6 N/2000 =72 72 V 446.4 =21" 2 "# M= ( 12 ) x 1000x 2 x12 = 735 SHEET NO. 5 JOB NO. RD -6486 items stored in rack polyester athletic clothing and accessories CITY OF TU JAN 2 2 2002 PERMIT CENTER ACTIVITY NUMBER: D02 - 018 DATE: 02 -07 -02 PROJECT NAME: High Five Sportswear SITE ADDRESS: 18200 Segale Pk Dr B SUITE # Original Plan Submittal Response to Incomplete Letter # l it ° Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: Building Division Public Works Complete { PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP n n Fire rP evention v '�•?�• Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete TUES /THURS ROUTING: Please Route -1 Structural Review Required Comments: REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: (4 weeks) Approved \PRROUTE.DOC 5/99 Approved with Conditions CORRECTION DETERMINATION: Approved Fi Approved with Conditions REVIEWER'S INITIALS: vc REVIEWER'S INITIALS: PERMIT COORD COPY Planning Division Permit Coordinator Not Applicable No further Review Required DUE DATE 03 -12 -02 DUE DATE: 02-1 2-02 Not Approved (attach comments) DATE: DUE DATE Not Approved (attach comments) DATE: z IZ CL w 00 J H w 0 u.¢ D. cy F. w Z � z� ILI al, U� O — G1 I- w • w w z U w . O Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: Plan Check/Permit Number: D02-018 ❑ Response to Incomplete Letter # Response to Correction Letter # I ❑ Revision # after Permit is Issued Project Name: Project Address: Contact Person: Phone Number: �J Summary of Revision: Department of Community Development - Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 (206)431 -3670 Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: ❑ Entered in Sierra on High Five Sportswear 18200 Segale Pk Dr B CITY RECEIVED FEB B ... PERMIT CENTER DEPARTMENTS: Building Division Public Works Complete n Comments: n u DETERMINATION OF COMPLETENESS: (Tues., Thurs.) TUES /THURS ROUTING: Please Route n Structural Review Required APPROVALS OR CORRECTIONS: (4 weeks) Approved Li Approved with Conditions a./to REVIEWER'S INITIALS: 1PRROUTE.DOC 5/99 CORRECTION DETERMINATION: Fire Prevention Structural REVIEWER'S INITIALS: PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D02 -018 DATE: 02 -07 -02 PROJECT NAME: High Five Sportswear SITE ADDRESS: 18200 Segale Pk Dr B SUITE # Original Plan Submittal Response to Incomplete Letter # I X Response to Correction Letter # ' Revision # After Permit Is Issued Planning Division Permit Coordinator DUE DATE: 02-1 2-02 Incomplete n Not Applicable No further Review Required REVIEWER'S INITIALS: DATE: DUE DATE 03 -12 -02 Approved n Approved with Conditions( I Not Approved (attach comments) n n Not Approved (attach comments) n DATE: 7 4 - 2A l o '1 -- DUE DATE DATE: ACTIVITY NUMBER: D02 -018 PROJECT NAME: High Five Sportswear SITE ADDRESS: 18200 Segale Pk Dr B SUITE # Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Jit Revision # I After Permit Is Issued DATE: 02 -01 -02 DEPARTMENTS: Bu vision �f Public Works Complete Comments: Please Route \PRROUTE.DOC 5/99 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP DETERMINATION OF COMPLETENESS: (Tues., Thurs.) TUES /THURS ROUTING: Structural Review Required APPROVALS OR CORRECTIONS: (4 weeks) Approved n Approved with Conditions CORRECTION DETERMINATION: Approved n Approved with Conditions Fire rP evention [ Planning Division V v Z•u.vz Structural Incomplete n Not Applicable I I n REVIEWER'S INITIALS: DATE: REVIEWER'S INITIALS: PERMIT COORD COPY Permit Coordinator DUE DATE: 02- 05-02 No further Review Required DUE DATE 03 -05 -02 Not Approved (attach comments) Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: DUE DATE II DATE: ai �rc!.1wy':v Y ;ikpiT +jq z 6 -1 C.) O 0 W� w 0 a u_¢ _ � w z� Z W 2 • o ui U 0- D 1-- w • w . L I Z ui U= 0 z Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: ° / i e, � ' Plan Check/Permit Number: r) D -- D ( ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # ❑ Revision # after Permit is Issued . Project Name: /L r-/ Y' o� `T'S� E !"‹ Project Address: 1--7 r Gc. C— �' -s�,,r Summary of Revision: Contact Person: City of Tukwila Department of Community Development - Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 (206)431 -3670 Received at the City of Tukwila Permit Center by: Entered in Sierra on o' f'07" JceA// Phone Number: oZd‘ �7c'v 4:7o L( VED CITY OF TUKWILA ' CI PERIUIIT C ENTER Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision 08/30/00 DEPARTMENTS: Building Division Public Works Please Route Approved \PRROUTE.DOC 5/99 TUES /THURS ROUTING: REVIEWER'S INITIALS: REVIEWER'S INITIALS: ACTIVITY NUMBER: D02 -018 DATE: 02 -01 -02 PROJECT NAME: High Five Sportswear SITE ADDRESS: 18200 Segale Pk Dr B SUITE # .Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # x Revision # I 1111ftemNIPPINIMIIMI Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete n Not Applicable Comments: Structural Review Required 1 APPROVALS OR CORRECTIONS: (4 weeks) Approved ith Conditions (!/L......„- CORRECTION DETERMINATION: Approved n Approved with Conditions REVIEWER'S INITIALS: PLAN REVIEW /ROUTING SLIP Planning Division Permit Coordinator DUE DATE: 02-05-02 No further Review Required DATE: DUE DATE 03 -05 -02 Not Approved (atta h co ments) DATE: ?� 5 2 DUE DATE Not Approved (attach comments) DATE: IAYi'�.SCS+.! z � 6 w� w g n u_a = - _ I- 0 Z I- w U � O N • F-- W W • II- - Iii Z 0 J Z ACTIVITY NUMBER: D02 -018 DATE: 02 -01 -02 PROJECT NAME: High Five Sportswear SITE ADDRESS: 18200 Segale Pk Dr B SUITE # X _Original Plan Submittal _ Response to Incomplete Letter # Response to Correction Letter # X Revision # II After Permit Is Issued DEPARTMENTS: Building Division Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: TUES /THURS ROUTING: Please Route REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: (4 weeks) Approved Approved with Conditions 54 Not Approved (attach comments) REVIEWER'S INITIALS: 01V-R— DATE: Z I ?41 C;"?--- \PRROUTE.DOC 5/99 PLAN REVIEW /ROUTING SLIP I Fire Prevention Structural Incomplete Structural Review Required CORRECTION DETERMINATION: Approved Approved with Conditions n n REVIEWER'S INITIALS: Planning Division Permit Coordinator No further Review Required DUE DATE 03 -05 -02 DUE DATE: 02-05-02 Not Applicable n DUE DATE Not Approved (attach comments) n DATE: z � Z ' r w QQ � JU O 0 U) 0 J F • = • u. w 0 2 u. Q I a . I-.w Z Z 111 Lu 0 - OH Ill W E- -Z ui U= 0 Z I ACTIVITY NUMBER: D02 -018 DATE: 01 -22 -02 PROJECT NAME: High Five Sportswear SITE ADDRESS: 18200 Segale Pk Dr B SUITE # Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: Building C�ivision MI Public Works Complete Comments: TUES /THURS ROUTING: Please Route Approved Approved \PRROUTE.DOC 5/99 CORRECTION DETERMINATION: PLAN REVIEW /ROUTING SLIP V V Fire Pr vention 1 Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: (4 weeks) Approved with Conditions Approved with Conditions Incomplete n Not Applicable REVIEWER'S INITIALS: II REVIEWER'S INITIALS: No further Review Required Not Approved (attach comments) Not Approved (attach comments) Planning Division Permit Coordinator II DUE DATE: 01-24-02 DUE DATE 02 -21 -02 n I I DATE: DUE DATE DATE: ? PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D02 -018 DATE: 01 -22 -02 PROJECT NAME: High Five Sportswear SITE ADDRESS: 18200 Segale Pk Dr B SUITE # X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: Building Division Public Works n Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete n Not Applicable Comments: TUES /THURS ROUTING: Please Route Struct r ral A Re w view Required vvl REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: (4 weeks) Approved I 1 Approved w'th Conditionse REVIEWER'S INITIALS: CORRECTION DETERMINATION: Approved \PRROUTE.DOC 5/99 Approved with Conditions REVIEWER'S INITIALS: No further Review Required Planning Division L i Permit Coordinator ri DUE DATE: 01-24-02 DATE: DUE DATE 02 -21 -02 Not Approved (att ch com ents) l I DATE: DUE DATE Not Approved (attach comments) DATE: w rt -J C.) 0 w� w gQ co a . Z �. 1- O Z ! - La U O - O I-- w uj HI- IL ui Z 0 = ` Z PERMIT NO.: D02,- DI 6 BUILDING PERMITS INSPECTIONS ❑ I Progress Inspection Status ❑ Pre - construction ❑ 3 Investigation ❑ 4 OK to Occupy ❑ 5 Remove Stop Work Order ❑ 6 Follow -up ❑ 7 Pre -Move Inspection ❑ 50 WSEC Residential ❑ 60 WA Ventilation/Indoor AQC ❑ 70 NLEA Inspection/Iviodular Stntct ❑ 71 Mobile Home Tie Down Insp ❑ 72 Marriage Lines ❑ 90 Resteel ❑ 95 Footing Drains ❑ 100 Foundation Footings ❑ 200 Foundation Walls ❑ 250 Foundation Insulation ❑ 300 Concrete Slab /Slab Insulation ❑ 350 Crawl Space ❑ 400 Shear Wall Nailing ❑ 450 Plywood Wall Sheathing ❑ 500 Roof Sheathing Nailing ❑ 525 Plywood Deck Nailing ❑ 550 Exterior Wall Sheathing ❑ 600 Masonry Chimney ❑ 610 Chimney Installation/All Types ❑ 700 Framing ❑ 750 Roof /Ceiling Insulation ❑ 800 Floor Insulation ❑ 801 Wall Insulation ❑ 802 Exterior Roof Insulation ❑ 803 Glazing Inspection ❑ 815 Lighting and Controls ❑ 900 Suspended Ceiling ❑ 1000 Interior Wallboard Fastening • ❑ 1001 Exterior Wallboard Fastening ❑ 1110 Pre -Move Inspection ❑ 1115 Motor Inspection ❑ 1120 Pre -Demo ❑ 1140 Pre-reroof ❑ , 1400 Final -Fire 700 Final - Building ❑ 1900 Final- Reroof ❑ 3100 Site Visit ❑ 4000 Special - Concrete ❑ 4001 Special -Bolts in Concrete ❑ 4001 Special- Mom/Resist Cone Frame ❑ 4003 Special -Reinf Steel Prestress ❑ 4004 Special - Welding ❑ 4005 Special -High- Strength Bolting ❑ 4006 Special - Structural Masonry ❑ 4007 Special -Reinf Gypsum Concrete ❑ 4008 Special- Insulating Cone Fill ❑ 4009 Special -Spray Fireproofing ❑ 4010 Special - Piling, Piers, Caissons ❑ 4011 Special - Shotcrete ❑ 401 Special- Grading, Exeav /Fill ❑ 4013 Special - Retaining Wall ❑ 4014 Special - Panels ❑ 4015 Special -Smoke Control System TENANT NAME: CONDITIONS Plan Reviewer: Permit Tech: (In ° Pi✓?. 51tr i 0001 No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division ❑ 10002 Plumbing permits shall be obtained through King Co ❑ 10003 Electrical permits obtained through L & I ❑ 10004 All mechanical work shall be under separate permit 10005 All permits, insp records & approved plans available ❑ 10006 All structural concrete shall be special inspected ❑ 10007 All structural welding shall be done by WABO certified inspector ❑ 10008 All high - strength bolting shall be special inspected ❑ 10009 Bolts installed in concrete shall be special inspected ❑ 10010 When special inspection is required—notity Tukwila Building Division I00I l The special inspector shall submit a final signed report 10012 Any new ceiling grid and light fixture installation 10013 Partition walls attached to ceiling grid 10014 Readily accessible access to roof mounted equipment 10015 Engineered truss drawings & calcs shall be on site 10016 Any exposed insulation backing material shall have 10017 Subgrade preparation including drainage, excavation 10018 A statement from the roofing contractor verifying fire retardant class of roof 10019 All construction to be done in conformance w /approved plans 10020 Structural observation shall be provided for this project 10021 All food preparation establishments must have King Co 10022 Fire retardant treated wood shall have flame spread of 10023 Notify Building Division prior to placing any concrete 10024 All spray applied fireproofing shall be special inspected 10025 All wood to remain in placed concrete shall be treated 10026 All structural masonry shall be special inspected 10027 Validity of Permit 10028 Rack storage requires separate permit ❑ 10030 No occupancy of building until final insp by Bldg Div ❑ 10031 Comply with requirements of TIM 16.04 ❑ 10032 Remove all weeds, concrete, stone foundations, fiat concrete ❑ 10034 Removal of septic tanks require approval and compliance with King Co Health Dept. ❑ 10035 Contact PW Div to obtain insp for water /sewer connect ❑ 10036 Manufacturers installation instructions required on site 10038 A C of O will be required for this permit 10039 Final approval for all TI w /in the limits of the SC Mall 10040 All construction noise to be in compliance with 8.2 TMC 1004 I Ventilation is required for all new rooms & spaces 1004/ Fuel burning appliances 10043 Appliances, which generate 10044 Water heater shall be anchored 10045 •Reroof "Anchoring — All new construct and substantial improvement shall be anchored to prevent flotation" 61-t, Date: Date: Z I i Z .1 C.) tJ 0 . co W= H co L W 2 LL. Q I W Z = F- 1-O W ~ W U O �. o � W W H H IL 6 W Z U= 17* - Z ACTIVITY NUMBER: D02 -018 DATE: 01 -22 -02 PROJECT NAME: High Five Sportswear SITE ADDRESS: 18200 Segale Pk Dr B SUITE # 1k Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: Building Division Public Works \PRROUTE.DOC 5/99 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete PLAN REVIEW /ROUTING SLIP n Fire Prevention Structural Incomplete TUES /THURS ROUTING: Please Route I I Structural Review Required Comments: APPROVALS OR CORRECTIONS: (4 weeks) Approved Approved with Conditions REVIEWER'S INITIALS: e (C7 J lLIZ- Planning Division Permit Coordinator DUE DATE: 01 -24-02 Not Applicable No further Review Required DUE DATE 02 -21 -02 Not Approved (attach comments) DATE: 1 Z.-91©'Z_ REVIEWER'S INITIALS: DATE: CORRECTION DETERMINATION: DUE DATE Approved ri Approved with Conditions Not Approved (attach comments) REVIEWER'S INITIALS: DATE: 1987 UNIFORM FIRE CODE SECTION 8101 — GENERAL ARTICLE 81 — HIGH -PILED COMBUSTIBLE STORAGE 8101.1 Scope. Buildings containing high -piled combustible storage shall be in accordance with Article 81. In addition to the requirements of Article 81, aerosols shall be in accordance with Article 88, flammable and combustible liquids shall be in accord- ance with Article 79, and hazardous materials shall be in accord- ance with Article 80. Storage of combustible paper records shall be in accordance with Article 81 and UFC Standard 81 -4. 8101.2 Definitions. 8101.2.1 General. For definitions of AEROSOL; ARRAY; ARRAY, CLOSED; BINBOX; COMMODITY; CURTAIN BOARD; EARLY SUPPRESSION FAST-RESPONSE SPRIN- KLER; EXPANDED PLASTIC; EXTRAHIGH -RACK COM- BUSTIBLE STORAGE; HIGH -PILED COMBUSTIBLE STORAGE; LONGITUDINAL FLUE SPACE; MANUAL STOCKING METHODS; MECHANICAL STOCKING METH- ODS; SHELF STORAGE; AND TRANSVERSE FLUE SPACE, see Article 2. 8101.2.2 Limited application. For the purpose of Article 81, certain terms are defined as follows: HIGH -PILED STORAGE AREA is an area within a building which is designated, intended, proposed or actually used for high - piled combustible storage. SOLID SHELVING is shelving that is solid, slatted, mesh, or grated located within racks that obstructs sprinkler water penetra- tion through the racks. 8101.3 Permits and Plan Submittal. 8101.3.1 Permits. For a permit to use a building for high -piled combustible storage, see Section 105, Permit h.3. 8101.3.2 Plans and specifications submittal. At the time of permit application, plans and specifications including the information specified in Section 8101.3.2 shall be submitted for review and approval. Following approval of the plans, a copy of the approved plans shall be maintained on the premises in an approved location. The plans shall include the following: r 1. Floor plan of the building showing locations and dimen- sions of high -piled storage areas. 2. ,Useable storage height for each storage area. 3. Number of tiers within each rack, if applicable. 4. Commodity clearance between top of storage and the sprinlder deflector for each storage arrangement. 5., Aisle dimensions between each storage array. . 6... Maximum pile volume for each storage array. 7. Location and classification of commodities in accordance with Section 8101.4. 8. Location of commodities which are banded or encapsu- lated. • 9. Location of required fire department access doors. 10.' Type of fire - suppression and fire - detection systems. 11. Location of valves controlling the water supply of ceiling and in -rack sprinklers. 't.i O It.N�.,^+.�r..M k•tt•.YrtirMt ;eM54o�:r•n;e.;�prAas.. fl w.. V2 ......�«.a.:.,.�,�.,.,.. 8101 8101.4.1.3 12. Type, location and specifications of smoke- removal and curtain board systems. 13. Dimension and location of transverse and longitudinal flue spaces. 14. Additional information regarding required design features, commodities, storage arrangement and fire- protection features within the high -piled storage area shall be provided at the time of permit, when required by the chief. 8101.3.3 Evacuation plan. When required by the chief, an evacuation plan for public accessible areas and a separate set of plans indicating location and width of aisles, location of exits and exit - access doors and exit signs, height of storage, and locations of hazardous materials shall be submitted at the time of permit application for review and approval. Following approval of the plans, a copy of the approved plans shall be maintained on the premises in an approved location. 8101.4 Commodity Classification. 8101.4.1 General. 8101.4.1.1 Classification of commodities. Commodities shall be classified as Class I, II, III, IV or high hazard in accordance with Section 8101.4.1. Materials listed within each commodity classi- fication are assumed to be unmodified for improved combustibil- ity characteristics. Use of flame- retarding modifiers or the physical form of the material could change the classification. See Section 8101.4.2 for classification of Groups A, B and C plastics. 8101.4.1.2 Class I commodities. Class I commodities are essentially noncombustible products on wooden or nonexpanded polyethylene solid deck pallets, in ordinary corrugated cartons with or without single- thickness dividers, or in ordinary paper wrappings with or without pallets. Class I commodities are allowed to contain a limited amount of Group A plastics in accord- ance with Section 8101.4.3. Examples of Class I commodities include, but are not limited to, the following: Alcoholic beverages not exceeding 20 percent alcohol Appliances — noncombustible, electrical Cement in bags Ceramics Dairy products in nonwax- coated containers (excluding bottles) Dry insecticides Foods in noncombustible containers Fresh fruits and vegetables in nonplastic trays or containers Frozen foods Glass Glycol in metal cans Gypsum board Inert materials, bagged Insulation, noncombustible Noncombustible liquids in plastic containers having less than a 5- gallon (18.9 L) capacity Noncombustible metal products 8101.4.1.3 Class II commodities. Class II commodities are Class I products in slatted wooden crates, solid wooden boxes, 1 -231 . COMMODITY CLASS SIZE OF HIIH•PILED STORAGE AREA (square feet) (See Sections 8102.2 and 8102.4 ) ALL STORAGE AREAS (See Sections 8102, 8103 and 8104) SOLID-PILED STORAGE, SHELF STORAGE AND PALLETIZED STORAGE (See Section 8103.3) Automatic Fire- e xtinguishing System (See Section 8102.4) fire - detection System (See Section 5102.5) Building Access (See Section 8102.6) Smoke and Heal Removal (See Section 8102.7) Curtain Boards (See Section 8102.8) Small Hose Valves and Sta. Lions (See Sec lion 8102.9) Maximum Pile Dimon- lions (feel) Maximum Permissible StorpQa Height' (feel) Maximum Pile Volume (cubic feet) x 0.0283 for m S x 0.0929 for m x 3048 for mm I -IV 0 -500 NRt NR NR5 NR NR6 NR NR NR NR 501 -2,500 NRI Yes NR NR NR NR 100 40 100,000 2,501- 12,000 Public accessible Yes NR NR NR NR NR 100 40 400,000 2,501 - 12,000 Nonpublic accessible (Option 1) Yes NR NR NR NR NR 100 40 400,000 2,501 - 12,000 Nonpublic accessible (Option 2) NRt Yes Yes Yes Yes Yes 100 30 200,000 12,001- 20,000 Yes , NR Yes Yes Yes Yes 100 40 400,000 20,001 - 500,000 Yes NR Yes Yes Yes Yes 100 40 400,000 Greater than 500,000 Yes NR Yes Yes Yes Yes 100 40 400,000 High hazard 0 -500 NRI NR NR NR NR NR 50 NR NR 501 -2,500 Public accessible Yes NR NR NR NR NR 50 30 75,000 501 -2,500 Nonpublic accessible (Option 1) Yes NR NR NR NR NR 50 30 75,000 501 -2,500 Nonpublic accessible (Option 2) NRI Yes Yes Yes Yes Yes 50 20 50,000 2,501- 300,000 Yes NR Yes Yes Yes Yes 50 30 75,000 300,001 - 500,000 Yes NR Yes Yes Yes Yes 50 30 75,000 COMMODITY CLASSIFICATION DESIGNATED STORAGE HEIGHT (feet) CURTAIN BOARD DEPTH (feet) MAXIMUM AREA FORMED BY CURTAIN BOARDS (square feet) VENT AREA TO FLOOR AREA RATIO MAXIMUM SPACING OF VENT CENTERS (feet) MAXIMUM DISTANCE TO VENTS FROM WALL OR CURTAIN BOARDS (feet) x 3048 for mm x 0.0929 for mz x 3048 for mm I -IV (Option 1) 20 or less 6 10,000 1:100 100 60 over 20 -40 6 8,000 1 :75 100 55 I -IV (Option 2) 20 or less 4 3,000 1:75 100 55 over 20 -40 4 3,000 1:50 100 50 High hazard (Option 1) 20 or less 6 6,000 1 :50 100 50 over 20 -30 6 6,000 1 :40 90 45 High hazard (Option 2) 20 or less 4 4,000 1 :50 100 50 over 20 -30 4 2,000 1 :30 75 40 J • • • • 1597 UNIFORM FIRE CODE TABLE 81 -A- GENERAL FIRE - PROTECTION AND LIFE - SAFETY REQUIREMENTS NR = Not required. t When fire sprinklers are required for reasons other than Article 81, the portion of the sprinkler system protecting the high -piled storage area shall be designed and installed in accordance with Sections 8103 and 8104. 2 For aisles, see Section 8102.10. 3 Piles shall be separated by aisles complying with Section 8102.10. 4 For storage in excess of the height indicated, special fire protection shall be provided in accordance with Footnote 8 when required by the chief. See also Articles 79 and 88 for special limitations for flammable and combustible liquids and aerosols. 5 Section 902.2 shall apply for fire apparatus access. 6 Curtain boards shall be installed as required by the Building Code. See UBC Section 906. 7 For storage exceeding 30 feet (914 mm) in height, Option 1 shall be used. 8 Special fire-protection provisions such as, but not limited to, fire protection of exposed steel columns; increased sprinkler density; additional in -rack sprinklers, without associated reductions in ceiling sprinkler density; or additional fire department hose connections shall be provided when required by the chief. 9 High -piled storage areas shall not exceed 500,000 square feet (46 451.5 m A two -hour area separation wall shall be used to divide high -piled storage exceeding 500,000 square feet (46 451.5 m in area. TABLE 81- B- REQUIREMENTS FOR CURTAIN BOARDS AND SMOKE VENTING (See Sections 8102.7.4 and 8102 8.3) tFor rack storage heights in excess of those indicated, see Section 8104.5. For solid -piled storage heights in excess of those indicated, an approved engineered design shall be used. 2 When areas of buildings are equipped with early suppression -fast response (ESFR) sprinklers, the curtain boards within these areas shall be located only at the separation between ESFR and conventional sprinkler systems. 3 The distance specified is the maximum distance from any vent in a particular curtained area to walls or curtain boards which form the perimeter of the curtained area. 4 TABLE 81 -A TABLE 81 -B 1 -237 U I I 1 RACK CONFIGURATION FIRE SPRINKLER PROTECTION SPRINKLER AT THE CEILING WITH OR WITHOUT MINIMUM IN -RACK SPRINKLERS IN -RACK SPRINKLERS AT EVERY TIER NON - SPRINKLERED s 25 feet (1620 mm) >25 feet (7620 mm) Any Height Any Height Storage Height Option 1 Option 2 Single -Row Radk Transverse Flue Space Size ( x 25.4 for mm) 3 inch NA 3 inch NR NR Vertically Aligned NR NA Yes NA NR Longitudinal Flue Space NR NA NR NR NR Double -Row Rack • Transverse Flue Space Size ( x 25.4 for mm) 6 inch 3 inch 3 inch NR NR Vertically Aligned NR NR Yes NA NR Longitudinal Flue Space NR 6 inch 6 inch NR NR Multi -Row Rack • Transverse Flue Space Size (x 25.4 for mm) 6 inch NA 6 inch NR NR Vertically Aligned NR NA Yes NA NR Longitudinal Flue Space NR NA NR NR NR TABLE 8104.3 -A 1 -238 TABLE 8104.3 -A— REQUIRED FLUE SPACES FOR RACK STORAGE 1997 UNIFORM FIRE CODE 1 NR means "not required." NA means "not applicable." 2 Random variations are allowed, provided that the configuration does not obstruct water penetration. 3 This option is not allowed with ESFR sprinkler protection. 1 77"..-:"..".77- •'• .74 , 9 0 0 PrOject Name Address • Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre-Fire: Permits: , - 2- C-' Authorized Signature FINALAPP.FRM ' ' . ••• • V •• • V v v v • •••• 3 . 1 , tV , City of Tukwila Fire Department TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM P‹• AR. 8 Retain current inspection schedule Needs shift inspection /».1 Approved without correction notice Approved with correction notice issued T.F.D. Form F.P. 85 John W Rants, Mayor Thomas P. Keefe, Fire Chief Permit No. PC..2 — 0/5 Suite # L6 7/1/1k/ Date Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575 • Fax (206) 575-4439 t+�' .4o4 Th Detach And DEPARTMENT OF LABOR AND INDUSTRIES REGISTERED AS PROVIDED BY LAW AS CQNST CONT GENERAL t :RscaS1 .1:1 EXP. - DATE CVO NannItU17547F Q U /2002' u f 06/1973 NORTH WEST HANDLING SYS INC 1100 SW 7TH ST RENTON WA 98055 -2939 : •. • .• Nu e% .Ana Dupls. Ceniticate REGISTERED AS PROVIDED BY LAW AS CONST CONT GENERAL REGIST. # EXP. . DATE CCO1 NORTHWH275JF '10/0112002' > >, EFFECTIVE DATE 04/06/1973 NORTH WEST HANDLING SYS INC 1100 SW 7TH ST RENTON WA 98055 -2939 DE? kR '\IE\T OF L.a3OR 4`D :NDcSTZ :,.i Please Reniov And Sign Identification Card Before Placing In Billfold 1R Need Current Contractor Registration Card: Yes Need to Enter Contractor Information in Sierra: 01 ❑ No 'DRAWING' NUMBER HIGH-FIVE ___ SHEET- DESCRIPTION RACK LAYOUT PROJECT TITLE _ -- -. HIGH FIVE SPORTSWEAR HANDLING SYSTEM$, - I100 $W 7TH. STREET RENTON RENTON WA. 98058 (425) 255.0500 I NC. - ANCHORAGE SPOKANE EUGENE YAK MA SHEET 1 SCALE AS SHOWN REVISIONS - - NOT PUBLISHED, ALL. RIGHTS. RESERVED THESE .DRAWINGS, SPECIFICATIONS, IDEAS, DESIGNS, AND ARRANGEMENTS THEREBY ARE ANO SHALL REMAIN THE PROPERTY OF ARM. NO PART THEREOF SHALL BE REPRODUCED, COPIED, ADAPTED, DISCLOSED OR DISTRIBUTED TO OTHERS, SOLD PUBLISHED OR OTHERWISE USED WITHOUT THE PRIOR WRITTEN CONSENT OF NORTHWEST HANDLING SYSTEMS. DRAWN IBM REM BRACE TO COLUMN CONN. BEAM CONNECTION COLUMN SECTION BEAM SECTION BOTH SIDE TY t=.07" SEC. A—A SEC. B—B BASE PLATE DETAIL ONE 3/80 ANCHOR PER BASE PLATE 2 1/2" EMB., (SEE NOTE NO. 4) 120" 144" 96" 108" 1 TYPE "A" RACK 1/8 TYP TH'K=1/8" FY=36 KSI. (ASTM A-36) F OA kr E lo BASE PL. & SLAB CONNECTION GENERAL CONFIGURATION RACK 7/16"0 RIVET ASTM A354-79 TYPE 1 5/8" 1E25 RACK D02-018 1-DEsIGN OF STEEL STORAGE RACKS AS SHOWN BY THESE DRA9KNGS »i� CALcuLATIoNS ARE IN COMPuN4cE wiTH THE REQUIREMENTS OF THE UNIFORM BUILDING CODE 1997 EDITION 2-STEEL FOR ALL SHAPES FY.50 KV. AM A570-115 08.50 (EXCEPT PS NOTED) 3-ALL, wELDED CONSTRUCTION IN A SHOP OF AN APPROVED FABRICATOR 4-wEDGE ANCHORS RAMSET RED HEAD ICB0 #13780R HILTI KwIK II #44127 (NO' SPECIAL P4SPECT1ON REQUIRED) 5-CONCRETE SLAB 5" THICK 2000 PS. SOIL BEARING CAPACITY 1000 PSF 8-SEISIAIC DESIGN OF STORAGE _RACKS BASED ON zobo 7-ALL' liACK INSTALLATIONS AND Wen MANUFACTURED nq CONFORMITY WITH THIS STANDARD SHALL DISPLAY IN ONE OR MORE CONSPICUOUS LOCATIONS A PERMANENT PLAGUE EACH NOT LESS THAN 50 SQUARE INCHES IR PIMA SHOVING THE MAXIMUM PERMISSIBLE UNIT LOAD OF 140t NO. 144", 120", 106" & 93" LONG CITY PERMIT CENTER 0 01 REV. DA RACK DES ICN AND ENGINEERING 3786 LA CRESCENTA AVE. #204 GLENDALE CA. 91208 DRAWN By: AAR, scALE: NONE DATE: 1-18-02 102" LONG % ( OI-I vPIRES It - 6._ _S I REvisiON PROJECT: HIGH FIVE SPORTSWEAR 18200 SEAGALE PARK DRIVE, SEATTLE, WA. Joe No. SHEET No. STORAGE RACK DETAILS R0 OF