Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D97-0098 - CASCADE CONTAINER - REROOF
City of Tukwila ' Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES, APPLICANT IS PROCEEDING AT THEIR OWN RISK. Parcel No: 352304 -9074 Address: 1232 ANDOVER PK W Suite No: Location: Category: ACOM Type: DEVPERM Zoning: Const Type: RE -ROOF Gas /Elec.: Units: 001 Setbacks: North: Water: TUKWILA Wetlands: Contractor License No:. JANNEECO33BS Permit Center Authorized Signature:'- DEVELOPMENT PERMIT Permit No: Status: Issued: Expires: Occupancy: UBC: Fire Protection: .0 South: .0 East: .0 West: Sewer: TUKWILA Slopes: N Streams: D97 -0098 ISSUED 03/28/1997 09/24/1997 WAREHOUSE 1994 SPRINKLERS /AFA .0 OCCUPANT CASCADE CONTAINER CO 1232 ANDOVER' PK W, TUKWILA WA 98188 OWNER WOELFL RUDOLF & HANNELORE 11956 WHITE WATER LANE, MALIBU CA 902659724 CONTACT .ERIC WOELFL . Phone: 206 313 -0235, ..1420 NW GILMAN BL #2854, ISSAQUAH WA 98027 CONTRACTOR JANNER.ENTERPRISES CORP . Phone:'206 -1457 . 1420' NW OILMAN BL #R851, ISSAQUAH WA 98027 k**************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Description: . REMOVE EXISTING WATER TIGHT ROOF MEMBRANE OVER SOUTHWEST CORNER OFFICE AREA AND INSTALL R -30 RIGID 'INSULATION. AND NEW MEMBRANE. ******************************** * * * * * * * * * * * * * * * * ** * * * * * * * * * * * ** Construction Valuation: $ . 10,000.00 PUBLIC WORKS PERMITS: *(Water Meter Permi,ts'Listed Separate) Eng. Appr: Curb Cut/Access/Sidewalk/CSS: N F.ire'Loop Hydrant: N No: Size(in): .00 Flood Control Zone: N Hauling: N Start Time:. End Time: Land Altering: N Cut: Fill: Landscape Irrigation: N Moving Oversized Load: N Start Time: End Time: Sanitary Side Sewer: N No:. Sewer Main Extension: N Private: N Public: N Storm Drainage: N Street Use: N Water Main Extension: N Private: N Public: N k**************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TOTAL DEVELOPMENT PERMIT FEES: $ 329.00 k**************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Date: (206) 431 -3670 EXPI ED I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this development permit.,, Signature: Date:___ Print Name: / ;k.k:_ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. CITY: OF TUB WILA :: Addr ess 1,232 ANDOVER ` PK W Permit Na 0i97- Q.11 Suite Tenant State. LSSUED Type • DEVFERM Appl i ed 173!25% 1X9,7 �ai;cel; # :352304 9074 Issued..` :03/28/1997 *:kk * *AA i.0 4: 0 k: kkkk** k* k**• AA X*AA-k k* k* �******: k•* *** *kAAkAAA*Ak *t�kA-A *`kk**'.•� * • • er�mit';:Condition� 1 No changes wi 11. he".,mad,e, to the ; p,lans' unless approved : "b_v the Architect ,;or Engineer :'and the T.ukwi la' :Bu.ildi'ng Di "vision 2 Al;:l permits, : inspection .recut ds, and approveci; p.lans"',shal l : b available ::at file lob` �s,:ite prior' to '€he st r t af ' any con st;r uctian These documen ;are t :be maintaitie "d a "nd avail- able until "f itral;f�'fispect:;ion :�ppr•o�ra i : i g, ,116iid 3 All construction to:be ` `:iri conformance with approved p lans an drrequlr en�eriirs of the Unlfor m 8ui,lding Co ` 1;994 Ed ame'nde'd: Uniform`: Mechani'ca,,l Code "11994; Ed`i'tion).. acid Wash :in'g ton .Stat`e . "Energy Code (1994 t ion) r` 4 Va.l id1"ty v.f Permi r The issi�ari,ce of.: :6: :per mil :.or approval ;cif plans .specifi ca. tions and - c;ompu,tat:i,ons. shal"l•T :be con s,true d torybe a .per mi t • fors',' or :ari approva .1 of t; any v i,olati`un.. ..:k of.;" ai y. of 4 'the p ;r ov i s i ons: of ''the building code or '`of ,any ng othi de!' of- the juri s.d , ict ion • No presumi: :t ivey'authori to v :iola'te,ar cancel °the s provi s ions at' this codAe s ha l .1u'' ;'v 1 td,,. Project Name/Tenant: CA- Sck - ?r, CoAI 1- //J 2 C,FR -L E.XF Value of Const tion: /o cam. — Site Address: ice-, Q City State/Zip: 0232 ,4,t.9 v5e. pAge__ W`ESf! , �l� Tax Parcel Number: cy 35-2 �" l ,�f' Pr G LFL_ RU 17dLF it h` '104.9 10e /21 Pho n C 6 / 39 Stre ddr s s: City State /Zip: v . cvy i � CAypai3 ED Sys 04 t Fax #: �8os 38G — 4 W5 Contractor: _ C,�r .5A 11 P - e EN I E2. le/ S CoeP & ANNEEm.1 3BS Phone: / 3 -02.35 2Gs) Fax #: (2‘- 313 -S%.( / Street Address: City State/Zip: / N w GI Lt L) #2854 /ssAcitokN (A/ A - y902 Architect: Hoer 3 �J 1--Assoc /AYES Phone: (2� t 32y — 99 Qo Street Address: City State /Zip: 3/3/ / / &) 17 . cc 5 4TT Aviv. Fax #: �� (006)325 206') 328 - �7 Engineer: N cif ti d 4 SOCfA -TES Phone: (20‘) 329 P/ o Street Addre City State /Z' /zO S /z7 ,4 VE. Su i - r /g 5FA -TTiE. G� ?c9 // Z. Fax #: t� ) 3z 2- Yz � Contac Pers on: � � �ro� >�sA,�,>i e �� � Phone: (2c ) 3/3 YOZ35 Street Address: City State /Zip: /'2a AJw c/ u-1Ar o 6L-u� - 2f's9 /ssA v.0'- coy Fax #: ( 31 3 - 5_/6 Description of work to be done: gEr - foUE_ Ey I siL& - 1.4.)A-TEE._ 77 4-'KT P-4=cF NEr /3 g.41,0 OvisR__ 3 kJ caieiJ E2- OFF C€ ,4-PEA- ) x 7 -4Gt— g - 3o p6-1 D bust- 4470k) , t- /u E) t1 16 Existing use: ❑ Retail ❑ Restaurant ❑ Multi- family ❑ Warehouse ❑ Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel U Office ❑ School /College /University ❑ Other Proposed use: ❑ Retail ❑ Restaurant ❑ Multi- family ❑ Warehouse Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel NI Office ❑ School/College /University ❑ Other Will there be a change of use? ❑ yes in no If yes, extent of change: (Attach additional sheet if necessary) Will there be rack storage? ❑ yes 19 no Existing fire protection features: 'sprinklers Eltautomatic fire alarm ❑ none ❑ other (specify) Building Square Feet: God existing Area of Construction: (sq. ft.) I 'OCO SF- Will there be storage of flammable /combustible hazardous material Attach list of materials and storage location on separate 8 1/2 in the building? ❑ yes IIII no X 11 paper indicating quantities & Material Safety Data Sheets CITY OF TUKWILA Permit Center 6300 Southcenter Blvd., Suite 100, Tukwila, WA 98188 (206) 431 -3670 ❑ Channelization /Striping ❑ Curb cut/Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: Size(s): ❑ Land Altering 0 Cut cubic yds. 0 Fill cubic yds. ❑ Sanitary Side Sewer #: ❑ Sewer Main Extension ❑ Storm Drainage ❑ Street Use ❑ Water Main Extension ❑ Water Meter /Exempt #• Size(s): 0 Deduct 0 Water Only ❑ Water Meter /Permanent # Size(s): ❑ Water Meter Temp # Size(s): Est. quantity: gal ❑ Miscellaneous CTPrRM!T.DOC 1/29/97 Commercial / Multi - Family Tenant Improvement / Alteration Permit Application Application and plans must be complete In order to be accepted for plan review. Applications will not be accepted through the mall or facsimile. APPLICANT REQUEST FOR PUBLIC WORKS:SITE/CIVIL.PLAN REVIEW OFTHE.F.OLLOWING (Additional reviews may be determined by the Public Works Department) ❑ Flood Control Zone ❑ Hauling ❑ Landscape Irrigation O Private 0 Public O Private 0 Public Schedule: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Data application accepted: Date ap limlion expires: � . J - c] Application taken by: (initials) KI P PLEASE SIGN BACK OF APPLICATION FORM 1.) BUILDING OWNER OR ' - •RIZED AGE ,T: Signature, ;�`� Date: - � I7 Y Print name /C . K CAJGV5 L/`"L Phone:.3 /3 `n2 3 Fax it: 3 // 3 _ s _ 7/‘ Address /920 iO() c/ GC ,44-) /U?) `f City /A l 4 N, cA.) 4, ?e9:707 ALL COMMERCIAUMULTI -FA V TENANT IMPROVEMENT /ALT TION PERMIT APPLICATIONS MUSE SUBMITTED WITH THE FOLL • ING: ALL DRAWINGS TO BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT, STRUCTURAL ENGINEER OR CIVIL ENGINEER ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN Y BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A SUBMITTED ❑ ® Complete Legal Description (Pi/ ❑ Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures (Form H -13). Business Declaration required (Form H -10). Four (4) sets of working drawings (five(5) sets for structural work), which include : ❑ ❑ Site Plan (including existing fire hydrant location(s) 1. North arrow and scale 2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements 3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions 4. Location of driveways, parking, loading & service areas 5. Recycle collection location and area calculations (change of use only) 6. Location and screening of outdoor storage (change of use only) 7. Limits of clearing /grading with existing and proposed topography at 2' intervals extending 5' beyond property's boundaries 8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of use only) 9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of those, identify by size and species which are to be removed and saved 10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change of use only) 11. Location and gross floor area of existing structure with dimensions and setback 12. Lowest finished floor elevation (if in flood control zone) 13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form H- 9). ❑ ❑ Floor plan: show location of tenant space with proposed use of each room labeled ❑ ❑ Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of any hazardous materials; dimensions of proposed tenant space. ❑ ❑ Vicinity Map showing location of site ❑ ❑ Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of rack. Structural calculations are required for rack storage eight feet and over. ❑ ❑ Indicate proposed construction of tenant space or addition and walls being demolished ❑ ❑ Construction details ❑ ❑ Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of water supply to sprinkler vault with documentation from contractor stating supply line will meet or exceed sprinkler system design criteria as identified by the Fire Department. ❑ ❑ Washington State Non - Residential Energy Code Data shall be noted on the construction drawings. ❑ ❑ SEPA Checklist - if intensification of use (check with Planning Department for thresholds). ❑ ❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other land use or SEPA decisions. ❑ ❑ Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County Department of Public Health prior to submitting for building permit application. The Department of Public Health is located at 201 Smith Tower, Seattle, WA or call (206) 296 -4787. (Form H -5) ❑ ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no contractor has been selected at time of application a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. c I I :RAMIT'.DOC 1/29/97 • .• CI TV •O T,U1041L A WA rPIisMIr ' 4,*****PP*9:kirA 'A:*******/***4************: ',".... ;.,T:ft A 14311ITf.Nu m b R37 . ARIOU 0 t1.... ' -: : ' 329..; 00 - 03/23/97 0938 :.. :N0im 6 'ri'''' . . 11 .tloil i 'icHECK: • Notation :. .:0411NER 'ENTER PR . . In it: ' SLB . , .... ,.... ... . . ...,, , . •.:. .. ,., ... ,.,.. , .. .„.- • : „• .. .. • . „ „ . . • :.-. ".i.,...,-....„ Pe•ifirit: NO:: , 'Typ: DEVPE,RM :.DEVELOPMENT 'PERMIT Parcel No: 352304-9074 :—•.: Bite .. .Acidr , ees: 1.232 'ANDOVER PK W . . . . Total Feee r.' 329..00 ' • This Payment :•,' ; : . 3,29.00 ,Tota 1 ALL Pmt: : ' 329.00 ' :',.. :. : . ' ' ' ' • : ' . ' : Hal anOe.: " .00 .. ***********************,i***** ' A OcOunt., Code • Deso,r i pt.i on. ' . : ' , Amount 000/322.100 l' BUILDING - NONRES ' . ' 324..50 060/386.904. ' • STATE BUILDING SURCHARGE - . 4.30 9000 03/29 9719 TOTAL 329.00 DAJE,_ Li C2 Cj - 7 4- — c CFR NO. ¶ioI- act P C ccQC o LOCATION l 3 Aneeve2 Pay-... L ItKw . 1 �. PERMIT NO'� OO H OWNER � ATHE R �ti(J TEMP. AT AM AT PM ENGINEER ARCHITECT (I CONTRACTOR TO: ATTN• AS REQUESTED BY: THE FOLLOWING WAS NOTED: COPIES TO CASCADE TESTI(f LABORATORY, INC, PREVIOUS REPORT No. No. 6 2 2 7 3 TESTING & INSPECTIONVAGINEER5 _. 12919 N.E. 126TH PLACE Y.IRKLANC, WASHINGTON EVER ETT F (161 40 (206) 823.7600 (206) 259.0817 c ' LTTiVCe.31 3 - 6 - c6 11 � Cry !,, � i k C 0Y 1 ; NW e'( YD k . �r�` 'tu)) tS►Ina -{k e - 6o ►'bi s) N_ \ 6.,(z o j 64-8 pokt LT1 tVA inl())( (gr' �1k \ "A) - P�IfS 5 ., � 0 73o (ls yylo_p � \ 5�c� a1Jns e� c�, ceirck pe�u.o.Q.e (AN - w INSPECTOR: FIELD REP SIGNED' . ;E'E ° ED APR COMM UNII - Y — �VELOPMENT Pro lJ✓ry iA) IVna- Type, lti N t Add e : A KI r 1 Spp .• ecial p i _' Date called: t4 Z-1 `97 instructions: Date wanted: Zz," p Requester: i L TOO 911 - 1Z 12 ' INSPECTION RECOL Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT NO. (206) 431 -3670 ..Approved per applicable codes. -: Corrections required,prior to ; COMMENTS: Inspector: $42.00 REINSPECTION FEE .REQUIRED. Prior to inspect on, fee must be paid at 6300 Southcenter Blvd., Suite 100, Call to schedule reinspection. Receipt No.: Date: Project � � D flP( Type of inspection: in r re. — Re Address/ f3 .5, poi(3 r i Y Date called: 3 _ ) Special instructions: Y()C.Q( c1 - -ID(a Date wanted: 3 T7 p.m. Requester: E� (t; PhoneNo.: S /5) Lis—) • INSPECTION RECOIL Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 D9 PERMIT NO. (206) 431 -3670 Approved per applicable codes. Inspector: [l $42.0 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection, Receipt No.: Corrections required prior to approval. , Date: 3 Date: r_h G<~•:4 «fA'ri:i� "„3:�. i'Vzr.?t: 7i >t ?,4* iL �bt n ish. pvei�t: i�:?.' 1' At �aiF..Yy4c45WC<�CR'9h,'�,7�n9e: iTRYi4tYY, PLAN REVIEW / ROUTING SLIP ACTIVITY NUMBER D 009, DATE 3•Q5• 9"/ PROJECT NAME Cascade Coniainer DEPARTMENT: BUILDING DIVISION • FIRE PREVENTION 0 PLANNING DIVISION ❑ PUBLIC WORKS I DETERMINATION OF COMPLETENESS: (T,Th) NOT COMPLETE ❑ COMMENTS • C:ROUTE -F TUES /THURS ROUTING: PLEASE ROUTE ❑ NO FURTHER REVIEW REQUIRED El ROUTED BY STAFF ❑ (If routed by staff, make copy to master file & enter Sierra.) REVIEWERS INMAL I 7 APPROVALS OR CORRECTIONS: (ten days) APPROVED n APPROVED W/ CONDITIONS REVIEWERS INITIAL CORRECTION DETERMINATION: APPROVED El El STRUCTURAL ❑ PERMIT COORDINATOR ❑ DATE DATE DUE DATE REVIEWERS INITIAL DATE DUE DATE Wiri NOT APPLICABLE ❑ q• Ira 97 NOT APPROVED (attach comments) ❑ 4 DUE DATE APPROVED W/ CONDITIONS ❑ NOT APPROVED (attach comments) ❑ (Certification of occupancy required. REVIEWERS INITIAL REVIEWERS INITIAL APPROVED D REVIEWERS INITIAL C:ROUTE -F CORRECTION DETERMINATION: Y"t': 140..Sia''i A.i;2.' S;o'.' .ykf+7a' & "•.?'i" oi.zei'rMli,4":`f.V4.i. 4tvzs•f 4�a51 ' i:fi2F,`Xi' 44:,, Ei:?Sli.'.'G � f APPROVALS OR CORRECTIONS: (ten days) DATE DATE DATE Prm C�ottL Copy PLAN REVIEW / ROUTING SLIP ACTIVITY NUMBER rqi 009? DATE 3•S 9 PROJECT NAME Cascade Corrialner • DEPARTMENT: BUILDING DIVISION 0 FIRE P ATI6N C PLANNING SION 0 PUBLIC W4RKS L STRUCTURN, 0 PERMIT COORDINATOR. DETERMINATION OF COMPLETENESS: (T,Th) DUE DATE 'COMPLETE n NOT COIYIPLE' COMMENTS NOT APPLICABLE N/p TUES /THURS ROUTING: PLEASE ROUTE n NO FURTHER REVIEW REQUIRED ROUTED BY STAFF El (If routed by staff, make copy to master file & enter Sierra.) •Vig: 4.4 �t.3 I DUE DATE /• 97 APPROVED n APPROVED W/ CONDITIONS E NOT APPROVED (attach comments) Ei DUE DATE APPROVED W/ CONDITIONS n NOT APPROVED (attach comments) 0 (Certification of occupancy required. ) City of Tukwila Department of Community Development November 29, 1999 Eric. Woelfl 1420 NW Gilman BI, #2854 Issaquah, WA 98027 Permit Status D97 -0098 1232 Andover Park West Dear Mr. Woelfl: In reviewing our current permit files, it appears that your permit for a reroof issued on March 28, 1997 has not received a final inspection as of the date of this letter by the City of Tukwila Building Division. Per the Uniform Building Code and/or Uniform Mechanical Code, every permit issued by the building official under the provision of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, if a final inspection is not called for within ten (10) business days from the date of this letter, the Permit Center will close your file and the work completed to date will be considered non - complying and not in conformance with the Uniform Building Code and/or Mechanical Code. Please contact the Permit Center at (206)431 -3670 if you wish to schedule a final inspection. Thank you for your cooperation in this matter. Sincerely, Brenda Holt Permit Coordinator Xc: Permit File No. D97 -0098 Duane Griffin, Building Official Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • (206) 431-3670 • Fax (206) 431-3665 01/b1/1994 07:24 2063135916 WOELFL ISSAQUAH fanner Enterprises 1420 NW Gilman Blvd. #2854, Issaquah, Wa 98027 .4 _ FILE COPY t FAX To: ie ) A) FLSOAJ Iv C./Tk OF 71)gw/LA. Phone: f2 t3 ' - 3(7 Fax phone: (Zoe 4'3' - CC: PAGE 01 Date: til9 /97 Number of pages including cover sheet: .Woelll Phone: (206) 313-0235 Fax phone: (206) 313 -5916 REMARKS: ❑ Urgent ❑ For your review ❑ Reply ASAP ❑ Please comment i AS Vow Ftgo5s7EP coPV o7C' Five-tit-WE i2.s RE Po i o) Rcor. Hop /lie.+ miv 74,40( Foe f- (JR ,/ice RECEIVED APR 1 0 1997 COMMUNITY DEVELOPMENT E 01/01/1994. 07:24 2063135916 WOELFL ISSAQUAH PG 03 21/U31355116; #3i3 c::4S , Asscc; ......4.1.••■•■••11•017•6i~imimmiumsift... ": :.*‘■ u6Gt4 041) ASSO7 KIMIARD HUDSON ft ASSOCIATES. INC. CONSULTING ENGINEERS 1805 13Th AVENUE • MU 18 MATTIS. WASHINGTON 98122 2064244010 I . : • I . .• ! '' '. .. .. : ' • • • : 1 4 • T P 3 r4ilkide,... ` ........: . , . , . i 1 . , ..,.... .....L... .. • I • . . ‘ : • i : - v5.4. 4. L.1:'.r. Z016 j _.ro.... ! .1...s.).tk..Tc*tom _ _. e.... 6: - 94. ' .,.,_ I, :. ;,._ . .:, • . i • , • , • 1 • . . , I.. ..4.•41111; ukkari...y. Tama it....L.U...._ . , . ...,,..—....— ,,,,„„„,_..?„p ' ) . . '..... • I: -- z '0•46Ni • i , ,. ... • • , . : • ' i : • 1 ... ! -- .. i ...•--- i. . , - •• .....-• • ' •■ --; • . • • —' - ,•^ '•• :•• • • • I. ---I ! • • . • • . .40a. , . Ci ILL .4) .. ..i _,-.14 .6! FA 6.0.... • • , , • hirtkrAitziti. ' • eI ; . . .• • Cop. • . . • i ; • oroiTe...r.v. L i • . 4 , , , ! ••• ,,A\5\ . • 144. 2,‘ • Aliii.(at tityali . . . • ,, \■.\\ - . - - ' • ' • ci \i ‘.- .• •N•e-*-. Its•• t.g.Drila .. i ...., ....... .. , i\ V 1 . ''-', • - -" ....Sig;41 ihiti-c-IVri., . I. : • : , 'MI . P‘ 1 1\.• • I A , .,. .. r „..--- - -. 1 , v ,\ L a 1 eat 4 t 4 owe/ :Autumn sy _ ciAT• ,,474 . . • E FILE COPY •M■wlawrft•■••••.ORM.M..a.r.••i....••••••.•.••*•..e.4.. • Nerv.t...214.1,144 4•224 liabisic1416,8.5. • ; • 1 -r- 01101/1994 87:24 2063135916 0••,•1 •!::•(') "!1 al . 9? &Et 1.6 it.16.9.:IN 4.1C11:iSSOC RICHARD ECTDOON de ABBOCIATE13, coNsrILTING EntaNssas 1603 47TH AVENUE • SUITE 11 se:Arms. WASHDIGION 98122 206-3244160 WOELFL ISSAQUAH ...tam'', JGO NOO I.417 AiNifh t MCC; 12 ANEW . .... • . . . I •..,..—. . . pu, v.%ipot:14. itair STOlar ...443ost .402+*%.0.......1"r? 1 ttk as/, i .riartacPri gv--C- • sk-01, ; ormitte cac..74A ofizAtiNt . . . . :Lcalars: thitakio . e)t.t. . 34.0. .i.ta4spo: ..( . : !I 0. , . ! I • ; • ...4- • • " bT 1 .1.44(s 6 64 4 .s 3 rio.k I 2. Of . et, Z5 i • • .. • ; .* " • "' — 1 ' , .,---. . --... 1," — . , ,.....p ..4. ; I tic!t. 4:14.....:... 1 ..thi...:...,-, Tow . tos+•- •b • qs)._ . -•:•• : 1....404.•••••• i • • -......-- • • • 1. , • . .14 1.!bi... . , . , , , ktt.v../.....*kiLsl., i • . I , • • ,• (asb.„...vivL6.47.i...GALLI ! I .1 . .1,r' zi.r.4.t!"4......... ! 4. 1 ts_o_0,4,4) 1322,...fIsi... .,.. ! _ . i .........).0..,....wilo ... Neb...)...,....zsih ..../.60.4.....;611.1..4i : ; . ; , . • • • 144•Icar... ... ...._.e...' g ■■' . '.. A Yip 1....i Ile . T•.... I'llitLAA:.. . ' • • L •-• • ' ' • • NI" — . - ' • -... 7 - - — • . - . - -- - , • - or. '... • L.1. ;.cruik./..i....464,mbrc, ....! ...1.;i7.2iat. ......z. i.iso. .: .. • •• --- ••• :. tiLv• gle: •■0. 1 ...• ...' , . .7 ...:$141 i (.......”._: to • ivic$ 1 : ; . i .•, ‘ 11;ft , , , ••I ..-----,---.• , 1 ' '• ; . 1..•—• "I " H . • : , IA? W hzi 1 " J 1 Lu FILE COPY ...------ ? . .0■\..Vo Go\\i‘s\c..) .„„ TtYbf tsthart.. ....turac i" ' - ' 1%` .. " • • ■ ........ ...ithminftwoorav uouratstr. ..1.0 - 4. 4 .4..•■ ■• • •‘g ....:.' Amor 40 .......-1—•■■•• M.CAILIMM• • . • PAGE 02 2083135918; #2/3 sit . . . .. . .... -1-.... . . . • ta..16 1 4 . .--..r.11__Ft....406...,.....••• .....:. . . - f • • I. . . . i : • L . .: h, ..:C01. * .4kaAci ..:,.....1. :,rtwpag.„:43441 if :. . ,. . , 1 t I MM.A601. .1.01.1. „ • .• • : . • :•• - • • ;( • • • • • 1�1LNI/V\IINIMI�1mMAII ,1 ^.r�� i�;•i�t ��%IILL =1t 1� \�It s■x — �: �r—= c� :��� wnr_:��► 1`��i1u �1w \Ia1 1 u V �4111�: I .W . I I it L_ 1 >y •n t_ a i c l2E e_0O / tj N O \-‘\\\, , r / \\// 11 PROVIDE A FLOOR OR LANDING NOT GREATER THAN 1 4" BELOW THRESHOLD AT ALL DOORWAYS. NO MATERIALS OR PRODUCTS CONTAINING ASBESTOS ARE TO BE UTILIZED IN THIS PROJECT. NO PRODUCTS ARE TO BE UTILIZED IN THIS WORK THAT WILL REQUIRE SPECIAL INSPECTIONS OF HAZARDOUS MATERIALS SHOULD THEY BE REMOVED. ALL CONSTRUCTION SHALL CONFORM TO THE 1994 EDITION OF THE UNIFORM BUILDING CODE. ALL CONSTRUCTION SHALL BE DONE N AC- CORDANCE WITH THESE PLANS 4 ANY PROJECT SPECIFICATIONS. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS. IN THE EVENT OF CONFLICTS OR CHANGES BETWEEN DETAILS OR BETWEEN THE PLANS 4 SPECIFICATIONS, NOTIFY THE ARCHITECT IMMEDIATELY. FINISH FLOOR REF. DATUM EQUALS (0' - "). REFER TO TOPOGRAPHIC SURVEY FOR ACTUAL SITE ELEVATION. ALL DIMENSIONS ARE TO FACE OF CONCRETE, MASONRY, FACE OF FRAMING OR COLUMN CENTER LINES LINO. ALL WOOD IN CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE TREATED WOOD PRESSURE TREATED WOOD OF ANY SPECIES OR FOUNDATION GRADE CEDAR OR REDWOOD. ALL MARKED BY AN APPROVED TESTING AGENCY. ALL WOOD FORMS USED FOR CONCRETE, IN THE GROUND OR BETWEEN FOUNDATION SILLS 4 THE GROUND SHALL BE REMOVED. PROVIDE HORIZONTAL FIREBLOCKING IN ALL FRAME WALLS AT 10' -0" O.C. 4 WHERE FRAME WALLS PENETRATE CEILING. FIREBLOCK IN ACCORDANCE WITH U.B.C. SEC. 108 -111, 114. ENCLOSED ATTIC SPACES SHALL SE DIVIDED INTO HORIZ. AREAS NOT EXCEEDING 9000 SF. WITH THE GREATEST DIMENSION NOT TO EXCEED 100 FEET. THESE AREAS SHALL BE DIVIDED BY PARTITIONS EXTENDING FROM THE CEILING TO THE UNDERSIDE OF THE ROOF DECK ENCLOSED SPACE (SEALED) BETWEEN FLOOR 4 CEILINGS SHALL SE DIVIDED INTO HORIZ. AREAS NOT TO EXCEED 1000 SF. THESE AREAS SHALL BE DIVIDED BY PARTITIONS EXTENDING FROM THE CEILING TO ROOF OR FLOOR MATERIAL SHALL BE 5/8" GYP. BD. OR 3/8" FLYWD_ OPENINGS IN PARTITIONS SHALL BE PROTECTED BY SELF GLOS. DRS. WITH AUTO. LATCHES, PER UB.G. 2516,F /4B /III/EXCEPTION. PROVIDE (I) 2A -10BC FIRE EXTINGUISHER (WALL MOUNTED) FOR EACH 3,000 SF MAX AND WITHIN 15' OF ALL LOCATIONS IN LEASE SUITE UNLESS DETERMINED OTHERWISE BY FIRE MARSHALL. MOUNT ®+5' -0" AFF. TOILET ROOMS SHALL HAVE SEPARATE AND INDIVIDUAL EXHAUST SYSTEMS IN A SEPARATE SHAFT. (SEE SEC. 1102.1 U.M.C. 4 W.SE.C.) TOILET ROOMS MAY BE UNDER COMMON SYSTEM, IF SYSTEM HAS NEGATIVE AIR PRESSURE IN ALL DUCTS. DAMPER 4 INSULATION REQ'D. ALL ROOMS OR AREAS HAVING AN OCCUPANT LOAD OF 50 (1500 SF OF RETAIL SPACE) OR MORE SHALL HAVE AT LEAST 2 EXITS TO THE EXTERIOR OR TO AN EXIT CORRIDOR ( ONE -HOUR CONSTRUCTION). ( U.B.C. 1003.1 ) EXITS SHALL HAVE A MIN. SEPARATION OF ONE HALF THE MAX. OVERALL DIAGONAL OF THE BUILDING OR AREA SERVED, MEASURED IN A STRAIGHT LINE BETWEEN EXITS. ( U.S.C. SECTION 10033 ) EN OSED INSULATION MATERIALS INCLUDING FACINGS AND VAPOR BARRIERS, SHALL HAVE A FLAME SPREAD RATING NOT TO EXCEED 25, AND A SMOKE DENSITY NOT TO EXCEED 450, OR SHALL BE IN SUBSTANTIAL CONTACT WITH THE WALL OR DEILING SURFACE FINISH. NBC. SECTION 1013) ELECTRIC RESISTANCE HEAT IS NOT ALLOWED_ UNLESS THE WASHINGTON STATE NON - RESIDENTIAL ENERGY CODE COMPLIANCE FORM 15 REVISED. LIMIT AIR LEAKAGE PER WSFC. SECT. 1314. 1 V/A SYJBO OFFICE 1 01 1,42 0 _" 950 SOFT. O I 11 - �0 BUILDING SECTION SECTION IDENTIFICATION LOCATED ON SHEET_ WALL SECTION SECTION IDENTIFICATION LOCATED ON SHEET_ DETAIL DETAIL IDENTIFICATION LOCATED ON SHEET INTERIOR ELEVATION ELEVATION IDENTIFICATION LOCATED ON SHEET ROOM SYMBOL ROOM NAME ROOM NUMBER ROOM MATERIAL CODES let No FLOORBASE 2nd No WALLS/WAINSCOT 3rd No CEILING CEILING HEIGHT SQUARE FOOTAGE GRID MARKERS LETTERS IN ONE DIRECTION NUMBERS IN THE OTHER DOOR SYME3T)L DOOR NUMBER WALL SYMBOL WALL IDENTIFICATION WINDOW SYMBOL WINDOW IDENTIFICATION NORTH ARROW BD. BLDG. BLK BLK'G. BM. BOT. B.U.R CAB. CB. CEM. CH. CU. CLG. CLR C.O. COL. CONC. CONK. COUNTR CONT. �:.T. CTR CTSK. DBL. DEPT. DET. DIA. DIM DN, DR DS. DWG. E. EA. EY S. EU. EL. ELEC. ELE, ENCL. E.P. I understand that the Plan Check approvals are subject to errors and omissions and approval of plans does not authorize the \'nlati Ho of cony adopted code or ordinance 'T ' 'wl rged ∎ tractor's copy of approved pla' \ By Data Permit No SU AND L ANGLE a AT S CENTERLINE DIAMETER OR ROUND 1 PERPENDICULAR POUND OR NUMBER A.B. ANCHOR BOLT ACOUS. ACOUSTICAL AFF. ABOVE' FINISH FLR AGGR AGGREGATE ALUM. ALUMINUM ANOD. ANODIZED APPROX. APPROXIMATE ARCH. ARCHITECTURAL ASPH. ASPHALT BOARD RD BUILDING BLOCK BLOCKING BEAM BOTTOM BUILT UP ROOF C ABINET CATCH BASIN CEMENT CHANNEL CONTROL JOINT CEILING CLEAR CLEAN OUT COLUMN CONCRETE CONNECTION CONSTRUCTION CONTINUOUS CERAMIC TILE CENTER COUNTER SUNK DOUBLE DEPARTMENT DETAIL DIAMETER DIMENSION DOWN DOOR DOWNSPOUT DRAWING EAST EACH EXTERIOR INSULATION FINISH SYSTEM EXPANSION JOINT ELEVATION ELECTRICAL ELEVATOR ENCLOSURE ELECTRICAL PANEL C L.41 u . C11( ION1th APPROV _7 :2. 6 1997 DING DIVISION N EQ. EQUAL O.C. ON CENTER EQUIP. EQUIPMENT O/ OVER EXIST. EXISTING OPP. OPPOSITE EXPO. EXPOSED EXT. EXTERIOR PL. PLATE P0.I.G. FURNISHED BY CANER PLYWD. _' WOOD INSTALLED BY CONY R. P.P. POWER POLE F.D. FLOOR DRAIN PLAM PLASTIC LAMINATE FE. FIRE EXTING- UISHER R RADIUS OR RISER FN. F IRE HYDRANT RD. ROOF DRAIN FIN. FINISH REC. RECOMMENDED FLASH. FLASHING REF. REFERENCE FLR FLOOR REINF. REINFORCED FLUOR FLUORESCENT REO'D. REQUIRED FOUND. FOUNDATION FIT. ROOM FRM'G. FRAMING FT. FOOT OR FEET S. SOUTH FTG, FOOTING S.C. SOLID CORE F FURRING E URR uRRING SGHED. SCHEDuL_ GA. GAUGE SHIT. SHEET GAL, GALVANIZED SHT'G. SHEATHING GO. GENERAL CONTR BIM. SIMI GL. GLASS SPEC. SPECIFICATIONS GND. GROUND SQ. SQUARE CsR GRADE STD. STANDARD GP. GROUP STL. STEEL GAWK. GYPSUM WALL STOR STORAGE BOARD STRUC. STRUCTURAL GYP. GYPSUM SUSP. SUSPENDED 5.4 V. STAIN AND ✓ARNIS. HDWR HARDWARE SVC. SERVICE HOOP. HAND ICAP SYM. SYMMETRICAL HDWD. HARDWOOG S/S SIDEWALK HB. HO5E Bee H.C. HOLLOW CORE T. "'REGO HM. HOLLOW METAL T.C. "'OF OF CURB HORIZ HORIZONTAL TEL. TELEPHONE HR HOUR T.4 G. TONGUE AND GROOVE HT. HEIGHT THK. THICK TOP. TOP OF PATE INST. INSTALLATION T.P. TOP OF PAVEMEN INSUL. INSULATION T.W. TOP OF WA INT. INTERIOR `'APICAL LAM. LAMINATED UB.C. UN!FORm Eu'_D'1NG LB. POUND CODE LOC. LOCATICN UHF. UNFINISHED U.ON. UNLESS OTHER'LiSE MATL. MATERIAL NOTED MAX. MAXIMUM MFR MANUFACTURER VERT. VERTICAL MJa. MANHOLE MECH. MECHANICAL W. WEST MIN. MINIMUM W/ MISC. MISCELLANEOUS AD. ,DOD MTD. MOUNTED WDW. WINDOW MTL. METAL W/O WITHOUT W.P. wATERPRCOF N. NORTH W.R WATER RESISTANT N.I.C. NOT IN CONTRACT WSCT, J„C.INSGCT NO. NUMBER WT. ,WEIGHT N.T.S. NOT TO SCALE oo O A -O01 COVER SHEET A -1.1 SATE PLAN A-21 FLOOR PLAN A-2.2 ENLARGED FLOOR PLAIN A -3.1 REFLECTED OOl,it'NG PLAN A -4,1 ROOF PLAN A-51 EXTEROR OL0VATOi.I S IA -C1.5 DETALS S FRAM!LNJO S -2 SECTIONS LOCATION: ZONING: OCCUPANCY: CONSTRUCTION: SITE AREA BUILDING AREA: PARKING PRO D EXISTING STALLS: NEW STALLS: TOTAL: NSULTANT OWNER JANNER ENTERPRISES 1420 N.W. GILMAN RD. SUITE 0 1854 ISSAQUAH, WASHINGTON 98021 P11:(206) 313 -0235 FAX, /206) 313 -5916 CONTACT: ERIC WOELFL ARCHITECT / PLANNER: STRUCTURAL ENGINEER KURT R JENSEN 4 ASSOCIATES 3131 EAST MADISON SUITE PEP SEATTLE, WASHINGTON 98112 PN:(208) 329 -9900 FAN:(206) 328 -1058 CONTACT: DAN R4SMUSSON THAT PORTION OF GOVERNMENT LOT 1, SECTION 35, TOWNSHIP 23 NORTH, RANGE 4 EAST, W.M. IN KING COUNTY, WASHINGTON, DESCRIBED AS FOLLOWS: BEGINNING AT THE NORTHEAST CORNER OF SAID GOVERNMENT LOT 1: THENCE N 8744'00" W ALONG THE NORTH LINE OF SAID GOVERNMENT LOT 1 A DISTANCE OF 949.49 FEET, THENCE S 01'51'39" W A DISTANCE OF 1,010.88 FEET TO THE TRUE POINT OF BEGINNING: THENCE CONTINUING S 01'51'39" W A DISTANCE OF 275.25 FEET TO T THE NORTHERLY MARGIN OF SOUTH 180th STREET: THENCE WESTERLY ALONG SAID NORTHERLY MARGIN AND ALONG A CURVE TO THE RIGHT, THE CENTER OF WHICH BEARS N 09'20'00" W, HAVING A RADIUS OF 270.00 FEET, AN ARC DISTANCE OF 96.18 FEET, THROUGH A CENTRAI. ANGLE OF 11'29'51 ": THENCE N 87'50'09" W ALONG SAID NORTHERLY MARGIN A DISTANCE OF 729.42 FEET: THENCE NORTHWESTERLY ALONG A CURVE TO THE RIGHT HAVING A RADIUS OF 50.96 FEET, AN ARC DISTANCE OF 19.35 FEET RECEI THROUGH A CENTRAL ANGLE OF 89'08'21" E, A CITY OF TUKWILA DISTANCE OF 393.00 FEET TO THE TRUE POINT OF MAR 2 5 1997 BEGINNING. L III (SPRINKLERZD) 92,539.1 SF. 45,050 SF. 42 STALLS B STALLS 45 STALLS Q TUKWILA, WASH■NGroN T.Q.C. B `4U1750N t ASSOCIATES 1605 12th AVE. SUITE 'IS SEATTLE, WASHINGTON 98122 P14:(206) 324 -6160 FAX: (205) 324 -5245 CONTACT: CHUCK MORRIS PERMIT CENTER 1 REGISTERED] ARCHITECT `, KUFJ NSEN DRAWN: CHf'_CK _;C:B NC. t=5 DR 3833 STA Ot`W 45H!NGTON I BLUE BACK- GROUND LW WHITE SYMBOL 4 LETTERING WHITE LETTERS w PHRASE "STATE DISABLED PARKING PERMIT REQUIRED" 2 "$ STL. POST CENTERED ON H.C. STALL CONC. FOOTING PARK (NCz S I CAN NTS 2 .610.014A NEw N.C. STRIPING/ CROSSWALK NEW RC. SIGNAGE EXIST. CONC. CURB EXIST. LANDSCAPING EXIST. STAIRS 4' -0" g PARKING PAINT SYMBOL WI 4" W1- ITE STRIPE NEW WHEEL CHAIR LIFT 150 LB. w 9 F.P.M. - PER WASH. STATE BF. CODE SECTION 110932 4 SECTION 1106.6 GRID FOR LAYOUT ONLY NOT TO BE PAINTED 2 / + -4,4ND (CAP 5 NTS 34 " =1' -0" 2.510.053 A NEW PARKING STALLS A -I.I 0 ml < EXIST. LANDSCAPING ; EXIST. CONC. CURB RE- STRIPE EXIST. PARKING AS NEEDED - PATCH 4 SEAL EXIST. ASPHALT AS NEEDED - EXIST. RAMP 9 . -0 .. V STANDARD STALL NTS 12 510.042 W AREA OF /W IMPROVEMENT PATCH ! SEAL EXIST. ASPHALT AS NEEDED RE- STRIPE EXIST. PARKING AS NEEDED EXIST. CONC. CURB EXIST. LANDSCAPING N 5750'9" W 229.42' CURB, SIDEWALK OR ,Y EDGE OF WHEE!.. STOP -P 4" PAINT STRIPE (2 COATS) 5 88'08 W 333.00' E UJARENOUSE PER PLAN 45,060 SF so CROSS WALK- i1' SITE FLAN SCALE: 1".20' I' -0" WIDE STRIPING PAINT (WHITE) TWO (2) COATS 1/2 " =1'-0" 1214Pe2 BOLLA RD 3/4"=P-0" 2.510.042 V/ 111 E tu � n O U� CONCRETE DOME w E 7 FILLED STEEL POST 6" DIA, CONCRETE IY W Q 4 Ul c� 4 ! ti Q1 RECEIVED CITY OF TUI(WILA 18" DIA. FOOTING MAR 2 5 1997 PERMIT CENTER DRAWN: CHECK: JOB NO: PS - PS 7:596 1 MAkK 0 rE LL SCP - -'1 ON 2/II/91 TENANT IMPROVEMENT PER1IT 9UE:MITTAL N i:97 o98 TUKW I L A, WASH INCETON FOR: JANNER ENTERPRISES FLOO1R i='LAN -01 Q0' r m 0 0 Z O 0 2 '1::9 AL C4SCADE CONTA I NE1R TENANT I1"1F OVEMENTS I>) © CD OO O LT) CDi &ASSOCIATES A R C H I 3131 EAST MADISON SUITE 200 SEATTLE, WASHINGTON 98112 (206)329 -9900 FAX:328 -7058 3 t9 tD S m 0 (� 1995 i NO .t OO JSiC, lV1.1Iv19R^o 1114J3d 1N3WW.Obd14 .LNIVN3J. I 000 � Nyw I DECK CLAM' ELASTOMETRIC MASTIC BELOW EPDM SHEET 3 N.T.S. N.T.S. EF'DM PIPE FLA5I -1INCB L L SEALANT COUNTER FL4SI -4I NCx FOR FARAfi ETS UNCURED FLASHING MEMBRANE ADHERED TO PIPE 4 MEMBRANE W/ APPROPRIATE ADHESIVE FLASHING EXTENDS 2" MIN. ONTO DECK SEAL EDGE OF FLASHING W/ LAP EDGE SEALANT EPDM MEMBRANE TURNED I" UP PIPE - C/ 3/4" PLYWD. SHEATH. ROOF DRAIN BASKET PER SPECS. SSS9P09 CLAMPING RING C A ROOF CANOPY EPDM MEMBRANE 0/ 3/4" PLYWD. SHEATH. CONC. WALL- EXPOSED SURFACE MUST BE WATERPROOFED CAULK W/ ELASTOMETRIC SEALANT ANGLE CLAMPING BAR W/ SLOTTED ANCHOR HOLES FASTENERS IN EXPANSION SHIELDS COMPRESSIBLE ELASTO- METRIC TAPE TO SPAN IRREGULARITIES CURED OR UNCURED FLASHING MEMBRANE ADHERED TO WALL 4 MEMBRANE W/ APPROPRIATE ADHESIVE EPDM MEMBRANE SEAL EDGES OF FLASHING W/ LAP EDGE SEALANT FASTENING STRIP APPLIED TO DECK OR WALL- FASTENED g 12" D.G. SS&SP10 3 Ilk nor FX/ST /� ROpF SL p F k�S7' /t ROOF Sl =a isry� ROOF EXIST. PIPES - VERIFY LOCATION —REMOVE EXIST. ROOF MEMBRANE, INSULATION t SHEATH'G: INSTALL EPDM ROOF'G MEMBRANE 0/ R -30 RIGID INSUL. 0/ 3/4" T4A PLYWD. SHEATH. \ • REMOVE EXIST. ROOF CRICKET - - -- REMOVE EXIST. ROOF —' MEMBRANE, INSULATION 4 SHEATH'G.- INSTALL EPDM ROOF'G MEMBRANE 0/ R -30 RIGID INSUL. Of _ 3/4" T<G PLYWD. SHEATH.' � NEW VENTING 4 EXHAUST FAN REMOVE EXIST. ROOF CRICKET 0 NEW CRICKE EXIST. 8 "4 ROOF DRAIN INTO EXIST. S.S. INSTALL NEW BASKET t HEAD A -4.I NEW CRICKET A -4.I 7 NEW CRICKET /717 1 N j / G1 EXPI EIO RECEIVED CITY OF TVKWILA MAR 2 5 1997 PERMIT CENTER DRAWN: PS CHECK: DR JOB NO: - 199& SHEET: 4-4_ 1 OF: 10 SHEE TS