Loading...
HomeMy WebLinkAboutPermit D97-0247 - FUJI TRU-COLOR - TENANT IMPROVEMENTCity of Tukwila Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 DEVELOPMENT PERMIT Parcel No: 262304 -9095 Address: 770 ANDOVER PK E Suite No: Location: Category: ACOM Type: DEVPERM Zoning: Const Type: Gas /Elec.: Units: 001 Setbacks: North: .0 South: Water: N/A Sewer: N/A Wetlands: Slopes: N Contractor License No:" PACIFCC123DD Permit Center Authorized Signature: Signature: Print Nam WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES, APPLICANT IS PROCEEDING AT THEIR OWN RISK. s be - r 4 1:; Permit No: Status: Issued: Expires: Streams: (206) 431 -3670 D97 -0247 ISSUED 08/21/1997 02/17/1998 Occupancy: WAREHOUSE UBC: 1994 Fire Protection: SPRINKLERED East: .0 West: .0 I h' rebv certify that I have read and examined this permit and know the same to be t_'rue and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this development permit. Date: d _ Q � This permit siall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. OCCUPANT FUJI_TRU -COLOR 770 ANDOVER PK E, TUKWILA WA 98188 OWNER BREKKE PROPERTIES Phone: 425 451 -1511 8592 HUNTS PT LANE, BELLEVUE WA 98004 CONTACT JAMES BAKKE Phone: 206.854 -5527 1209 S CENTRAL, KENT WA 98032 CONTRACTOR PACIFIC CONCRETE CONST INC. Phone: 253.862 -4813 10116 221ST AVENUE EAST, BUCKLEY, WA 98321 k * * * * ***** *Jc*9c** ** **** * ********** * *** ** ** * * * **** ***** *** * ** * * **** **** *YIr** * * * ** * * * ** Permit Description: CONSTRUCTION OF INTERIOR FRAMED WALLS AND CEILINGS, DRY TRENCH AND MEZZANINE. REPLACE EXIS- TING CATCH BASIN IN THE PARKING LOT WITH A NEW TYPE 2 CATCH BASIN TO ACCOMMODATE EMERG OIL /WATER SEPARATOR. = k**************************************************** * * * * * * * * * * * ** * * * * * * * * ** * * * ** * ** Construction Valuation: $ 120,000.00 PUBLIC WORKS PERMITS: *(Water Meter Permits Listed Separate) Eng. Appr: JJS Curb Cut/Access/Sidewalk/CSS: N Fire Loop Hydrant: N No: Size(in): .00 Flood Control Zone: N Hauling: N Start Time: End Time: Land Altering: N Cut: Fill: Landscape Irrigation: N Moving Oversized Load: N Start Time: End Time: Sanitary Side Sewer: N No: Sewer Main Extension: N Private: Public: Storm Drainage: Y Street Use: N Water Main Extension: N Private: Public: k************ k*************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * *** TOTAL DEVELOPMENT PERMIT FEES: $ 1,658.46 *************************************************************** * * * * * * * *** * * * * * * * * *k ** � uL�L VCT.QQ___ Date : `6-- • • Address: 770ANDOVER PK E Tenant: Tye: lDEVPERM Parcel#:. 262304-9095 . tITY, TUKWILA Permit No: D97-0247 Status: ISSUED Applied: 07/21/1997 Issued: 08/21/1997 - , k Permit Conditions.: 1. APPLICANT MAY NOT DISCHARGE INDUSTRIAL WASTE TO THE CITY SANITARY SEWER SYSTEM UNTIL,H.E-REPEIVgS AN APPROVED_ INDUS- TRIAL WASTE DISCHARGE,..p.ERMft400INGCOUNTY METRO. No changes will te,medee plani by the Architect or EngTneeYand"thtjukwila Buliding Division 3::Plumbing perrn 2 the''Saattla-King County Depat,tMentofPubliC Health Plumbing will be Anspectedi*Ahata0n.cY, including all gas piping J296-4722 4, Electricali''permitSshall be obtained through the Washington State' pf4isionpf:Labor and'IndUries and all electrical work WA4l be inspected by that agency (248-6630 . 5 All me:Chen'ical work shilUbe,underseparate permit iSSUedbY. the .City Of'“ukwila. 6 An'Spection recordS,'and, approved plans sha1:1 be available at the job'tlteprlbr to the start of any , struCtion. dOCOments,are to-,ba and . - , abluntil.jinalAnspection:approitaLisArinted. 7 AliconstrUctio*to. be doneinoonforMancewithlapproved plans and Of the UniforM-BUilding Code j1994. Edftions amended, Uniform,MechaniCal Code (1994 Edition}, and,Wash State:Eneygy Code (1994 Edition) 8. Altchighstrehgth bolting special inspected NBC:— •• ,• 9, Allstr6Cturalwelding shall be:donebyW.A certified welders and Special inspected (UBC-: Sec. 306(a)5) . 10. WhenSpecial inspection is required either the owner, architect or engineer shall notify the Tukwila.:Building DiviSiohof appointment of the inspection agencies ,prior to the firSt':,building inspection. Copies of all special inspectionTepos, shall be submitted to the Buil:ding Division in'...atimely manner. 'Reports shall contain :address, project nameermit number:andtype:of inspection:being performed. 11. The special inS06ctOr shall subMit2a final signed stating whether thework,requiring special inspection was, to the best of the inspectors , knowledge, :in conformance with approved plans and specifications and the applicable workmanship provisions of the UBC. 12. A CERTIFICATE OF OCCUPANCY WILL BE REQUIRED FOR THIS PERMIT. 13. Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be con- strued to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. Project Name/Tenant: Pt1J1 `(1tUcCLore- ING.. Valu o onstruction• � , uru. =' Site Address: 11Q City State /Zip: NOO Ve12 ?Alt* eitSt Tax Parcel Number: ZWZ, rl or Property O e et P Rep vt IES Ph ne: p L : b �5I- ISI1 Street Address: City Sta / i S;;2 *fi CA, ► �u� Fa Contractor: Phone: Street Address: City State /Zip: Fax #: -Arehiteet:PSWOOL' C$ +) Hopi 4 AcSoc4 (lam . ra 3 ) 2 74 -0z44- tthe A dress: it lo City St a /Zip: tLo/ko IAA. , # . IN* a Y4 Z F x # 621 23) — 3'W 0 t Enyl i ne leyetips l ut ome P Zo)z1Z -454 S rest es"s: it State /Zip: W igKsA ( Sur i0�,TI co �. iu - 44 402 #: 0/ Z -g0 3 4 Cojt tKe _ �(�lt I hone �!- 2a -5 21 eet Ad e ss 470Siate/Zip: Viol 4 rTR , I 'C 1�1/ O- c � SSS4 -, 4 Description of work to be done: I •- &1 FM1A -tnl<w W A . 1-uS si eEu..i Nlv S r D IZr T rt ii-J, mezzo Nf, Existing use: ❑ Retail ❑ Restaurant ❑ Multi- family ❑ Warehouse in Hospital ❑ Church ia Manufacturing ❑ Motel /Hotel ❑ Office ❑ School /College /University ❑ Other Proposed use: ❑ Retail ❑ Restaurant ❑ Multi- family ❑ Warehouse El Hospital ❑ Church SI Manufacturing ❑ Motel /Hotel ❑ Office ❑ School /College /University ❑ Other Will there be a change of use? ❑ yes XI no If yes, extent of change: (Attach additional sheet if necessary) Will there be rack storage? 53 yes ❑ no Existing fire protection features: XI sprinklers ❑ automatic fire alarm ❑ none ❑ other (specify) Building Square Feet: 63,1 24 existing Area of Construction: (sq. ft.) l(o, lac. Will there be storage of flammable /combustible hazardous material in the building? Iii, yes ❑ no Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets CITY OF TUK. 'ILA Permit Center 6300 Southcenter Blvd., Suite 100, Tukwila, WA 98188 (206) 431 -3670 CTPI:RMIT.DOC 1/29/97 Project Number: Permit Number: Commercial / Multi - Family Tenant Improvement / Alteration Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. APPLICANT REQUEST FOR PUBLIC WORKS SITE/CIVIL PLAN REVIEW OF THE FOLLOWING: (Additional reviews may be determined by the Public Works Department) ❑ Channelization /Striping ❑ Curb cut/Access /Sidewalk ❑ Flood Control Zone ❑ Hauling ❑ Fire Loop /Hydrant (main to vault) #: Size(s): ❑ Land Altering 0 Cut cubic yds. 0 Fill cubic yds. ❑ Landscape Irrigation N ❑ Sanitary Side Sewer #t: ❑ Sewer Main Extension 0 Private 0 Public Storm Drainage ❑ Street Use ❑ Wa ter Main Extension 0 Private 0 Public Water Meter /Exempt #: Size(s): 0 Deduct 0 Water Only ❑ Water Meter /Permanent # Size(s): ❑ Water Meter Temp # Size(s): Est. quantity: gal Schedule: ❑ Miscellaneous Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit Is issued within 180 days following the date of application shall expire by limitation, The building official may extend the time for action by the applicant fora period not exceeding 180 days upon written request by the applicant as defined In Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date application accepted: Date application expires: Application t ken : (initials) i PLEASE SIGN BACK OF APPLICATION FORM BUILDING 1 WNER OR A , THO'I ZE 0 . GENT: Signature 111P9 A -, it Phone:. Z Date: 1 , it ?4,,B 1 , 9 Fax it:z y -. 3 • 6 27. 30 6:7E, Print name' • jv o !) . s - w , pi Address'707i 520kVWl°Ef 50 t 02._ Cit /State /zip T 44. t*.) t. elf (kU 2 ALL COMMERCIAUMULTI-FIBLY TENANT IMPROVEMENT /AL • ATION PERMIT APPLICATIONS MBE SUBMITTED WITH THE FOLLOWING: Y ALL DRAWINGS TO BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT, STRUCTURAL ENGINEER OR CIVIL ENGINEER ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A SUBMITTED ❑ ❑ Complete Legal Description ❑ ❑ Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures (Form H -13). Business Declaration required (Form H -10). Four (4) sets of working drawings (five(5) sets for structural work), which include : ❑ ❑ Site Plan (including existing fire hydrant location(s) 1. North arrow and scale 2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements 3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions 4. Location of driveways, parking, loading & service areas 5. Recycle collection location and area calculations (change of use only) 6. Location and screening of outdoor storage (change of use only) 7. Limits of clearing /grading with existing and proposed topography at 2' intervals extending 5' beyond property's boundaries 8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of use only) 9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of those, identify by size and species which are to be removed and saved 10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change of use only) 11. Location and gross floor area of existing structure with dimensions and setback 12. Lowest finished floor elevation (if in flood control zone) 13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form H- 9). ❑ ❑ Floor plan: show location of tenant space with proposed use of each room labeled ❑ ❑ Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of any hazardous materials; dimensions of proposed tenant space. ❑ ❑ Vicinity Map showing location of site ❑ ❑ Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of rack. Structural calculations are required for rack storage eight feet and over. ❑ ❑ Indicate proposed construction of tenant space or addition and walls being demolished ❑ ❑ Construction details ❑ ❑ Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of water supply to sprinkler vault with documentation from contractor stating supply line will meet or exceed sprinkler system design criteria as identified by the Fire Department. ❑ Washington State Non - Residential Energy Code Data shall be noted on the construction drawings. ❑ ❑ SEPA Checklist - if intensification of use (check with Planning Department for thresholds). ❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other land use or SEPA decisions. ❑ ❑ Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County Department of Public Health prior to submitting for building permit application. The Department of Public Health is located at 201 Smith Tower, Seattle, WA or call (206) 296 -4787. (Form H -5) ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no contractor has been selected at time of application a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal ( HERE PENALTY CTPF,RMIT.DOC 1/29/97 CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND / AM AUTHORIZED TO APPLY FOR THIS PERMIT. :1- ACTIVITY NUMBER D97 -0247 COMMENTS • REVIEWERS INITIAL REVIEWERS INITIAL REVIEWERS INITIAL C:ROUTE -F TUES /T$URS ROUTING: PLEASE ROUTE CORRECTION DETERMINATION: CATION: APPROVED l l APPROVED W/ CONDITIONS • PQXtt'* C.OtAi4% • Cop PLAN REVIEW / ROUTING SLIP PROJECT NAME FUJI TRU COLOR — CORRECTION 11 DEPARTMENT: BUILDING IVISION FIRE PREVENTION P G DIVISION Awc Sao /q� � 1 � _ _._. PUB IC 0 STRU E PERMIT COORDrNAT0P 1 Awe-. ]A111 A DETERMINATION OF COMPLETENESS: (T,Th) DUE DATE 8/19/97 COMPLETE 71 NOT COMPLETE n NOT APPLICABLE ROUTED BY STAFF El (If routed by staff, make copy to master file & enter Sierra.) DATE APPROVALS OR CORRECTIONS: (ten days) APPROVED n APPROVED WI CONDITIONS El DATE DATE DATE 8/15/97 NO FURTHER REVIEW REQUIRED DUE DATE 9/02/97 ' r NOT APPROVED (attach comments) i DUE DATE NOT APPROVED (attach comments) 0 (Ctniftcatioa of occupancy rcquirsd. ) • ACTIVITY NUMBER PROJECT NAME i I. . 1 �� CAD k ( J- nL . P ' TMENT: 9 1 511747 ;1 1 � PUBLIC .nk<U q-c-gi COMPLETE COMMENTS REVIEWERS INITIAL �ernu:� c.O._01014-a PLAN REVIEW / ROUTING SLIP - co2-r FIRE PREVENTION I W DETERMINATION OF COMPLETENESS: (T,Th) NOT COMPLETE Ei • APPROVALS OR CORRECTIONS: (ten days) DATE TUES /THURS ROUTING: PLEASE ROUTE n NO FURTHER REVIEW REQUIRED El ROUTED BY STAFF n (If routed by staff, make copy to master file & enter Sierra.) DATE V9-//, � ri P G DIVISION 0 P COORDINATOR MI DUE DATE " -.) NOT APPLICABLE ❑ DUE DATE //'7 sB r7.71 Hoc P APPROVED El APPROVED W/ CONDITIONS NOT APPRO D (attach comments) L( ((Cc n l •� 610 (l e' - -ed REVIEWERS INITIAL ... DATE CORRECTION DETERMINATION: APPROVED 11 APPROVED W/ CONDITIONS fl NOT APPROVED (attach comments) 0 REVIEWERS INITIAL C:ROUTE -F DATE DUE DATE (Certification of occupancy required. ************** ,kik * ** * ** * * * * ** *** *4 *A*kA *4 ** * **.i *k *A # * * ** *A** * ** CITY OF TUKWILA, WA q � fRANSi4IT. *lc *k** * * * ** * *k ** ***#* **' **+ * *4 * * *'/ * * * **�R� " * *fi * * * *A * * * * ** *1l ** TRANSMIT Number: R9700631 Amount: 25.00 08/21/97 17:09 Payment Method: CASH Notation: JAMES BAKKE Init: SLR Permit No: .D97 -0247 Type: DEVPERM DEVELOPMENT PERMIT Parcel No: 262304-909.5 Site 'Address: 77.0 ANDOVER PK E Total Fees: 1,658.46 This Payment 25i00 Total`. ALL Pmts: ` 1,658.46 Balance: .00 ****, n**************************** A* * * * * * * * * * * * *A * *i * *A * * * * ** Account Code Description Amount 000 /345.830 PLAN CHECK UTILITY 10.00 412/342.400 INS'' FEE - STORM DRAIN 15.00 i ; 31 :: >O 08/22 9717 TOTAL 25.00 ' : ++******^*^k+A**++*A++**+ / ****a*** '+ 'CITYAF TUKNILA, NA ` ' TRANSMIT ***++++**aAko+*A*k*k***� v�� *��w��*+�**�������+�*�k*****k*kkka**+A++* TRANSMIT ' . Number: R9700617-Amount: '1 633 46 07/21/97 09:19 Payment Method: CHECK Notation: FUJI TRUCOLOR Init: KJP Permit No: D97-0247 Type: DEVPERM DEVELOPMENT PERMIT Parcel No: 262304-9095 !lte Address: 770 ANDOVER PK E Account Code 000/322.100 000/345,830 000/386.904 This Payment 1,633,46 Description BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE TRANSMIT, Total Fees: 1,633.46 Total ALL Pmts: 1,633.46 Dalance: .00 *+A°***aA*+**a**71*****+*1.**+****AA***a+*+Ak*+++*+++******+a*^*** Amount 987.25 641,71 4.50 2383 07/23 1719 TOTAL 1633.46 -'� : k **kk * *k *k* * *: *• k***A:i •k•kA.;k* +•A tk: t: t**; t*^ tktit*. * * *Akk:t•M•k:k4 #•A *A:krot CITY. OF TUKWILA .A. Y q 1 - �Z }. TRANSMIT ** *:1 *qt. trot * ***A * *Ak ** *• *** * ***,A*A* **•k. *:A*A:k *A ***A* *A A ..*:A*A* *•t *•k 1 RA'rl3MTT''Number R9800022 Amount: 47.00 02/I7/' 08 :52 Payment: Method: CHECK Notation: JAMES BAKK1= In it: TLU Permit No: D97-0247 Type: DEVPIZRi4 DEVELOPMEt11 PERMIT Parcel No: '• 262304-9095 S ite .Address 770 ANDOVER Pit E ' iota] Feee: 1 . 46 This Payment 47.00 Tatetl ALL Pmts; 1.705.4u R a I ance: .0t; • A** lost**** *•***4rot***•A****rot•***•A•** ask *•*A**k* *k*i•hrot **4* *#****'I d*A* Account; Code 000/G22Y300 DeScl' i pt i of R11I:LI }I:NG INVESTIGATION (am ount 47000 «715(1 02/23 9717 TOTAL, 47.00 F'rojec , i .... ..... t I Type of In pection: Address: r i r l D Alilk Pk E Date call d: Special instructions: Date wanted: p.m. Requesterk Phone: z2,3-5 CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 9818 INSPECTION NO: INSPECTION RECORD Retain a copy with permit PERMIT NO. (206)431-3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: Fte-AA ( T p,de-A net kfor7c(cAriod 3 .S Gg,7 (V / )li&PC(7719 ..tfo Acce 5 5 p. /edge-fib D7/3 $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: 14 • Pr.ojct -Name /' a,/ / / / U 0 -0 t/4., Address • 7 7 0 /1` :' I Retain current inspection schedule Needs shift inspection Approved without correction notice Approved with correction notice issued Sprinklers: J Fire Alarm: r �// / 1,, Hood & Duct: _ ..' Halon: //' Monitor: / 2 i L r ,, e t rx. J'VC• Pre-Fire: A Permits: Authorized Signature City of Tukwila Fire Department PINALAPP.FRM Rev. 2/19/98 TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM I..• A1/ John W. Rants, May /r Thomas P. Keefe, Fire;Chief Permit No ) 9' "" 0/70".7 ; 9 7 - 6 . f 7 :9 Suite # 4/)-- -0, F Date T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206) 575.4439 • Project: r ' •i r Type of Inspection: fi ', Cfe'9 /-P Address: r 77O Al0, ,y.£ Date cal Special instructions: i 1 1Vi Date wanted:.. a.m. Requester: ta ,/, fr1e •./ 710 _. r Phone: . • "7/76 -- 6 2345% rir INSPECTION RE Retain a copy with �frdmi INSPECTION O. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 Approved per applicable codes. Corrections rdquired prior to approval. COMMENTS: c(ge- rz=S7 - • te • • $• 7.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: • ./ • PERMIT NO. 7-Ot (206)431 -3670 Project: Type of Ins on: / �.< Addre " : _ tJ Date called: Special instructions: Date wante_ ti� a.m .m. Requester: Phone: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 Approved per applicable codes. COMMENTS: A40:&/ 0:&/ ' / -(- 4 / 71 Date: 1 74.7 , Q $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Cali to schedule reinspection. Receipt No: Date: INSPECTION RECORD Retain a copy with permit Corrections required prior to approval. PERMIT NO. Y (206)431 -3670 . Project: ri 1 Type of Inspection: ......" A ss: Date called: 'Special instructions: 3D m /7--e' � So , C/,a1( 4- .fay >> Date wanted: !1 a.m. p.m. Requester;... Phone: ac- �� 7 INSPECTION RECORD Retain a copy with permit INSPECTION NO. ..CITY. OF TUKWILA BUILDING. DIVISION .6300 Southcenter Blvd, #100, Tukwila, WA 98188 PERMIT NO. (206)431 -3670 AppSro_ved per applicable codes. aCorrections required prior to approval. COMMENTS: A- lI ?Le 41e.... / -9l -. e/4, G , ^ z��1 � y /4, .00 REINSPECTION REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: COMMENTS: 6 ,J 2,),.pc,o_v_ck..._____z _ I A‘ee - ,-.4 eefr ), e j , , • 4.3 -, co r ,,, Allf 4, L S ho l / rl,;ed at-, 1,00.i/e. a /o72., 'W,e42_/ 6.1,,, --b l) 401- C l/OGGeU ,z-, L..y., /lJl l- a f Ltd a G/ W►1 j 01,E ) ge ,; yd // -e6w e e60-7,D 7 'm z ' c.,1 c.00/1-- halci (peAf_s, e coot,&) A:- 6144- ce. //f., 1 de:leA- j4 y' n,/ i.hre— dii2 k—jed elf 22 Project : f �f� . 0lvt �" Type of inspection: / �� Addres © /— Date called: Special instructi�r f Date wanted: Q a Requester: Phone No.: riggVaPsiteRliveopwrowo INSPECTION RECORD Retain a copy with permit Approved per applicable codes. Inspector: INSPECTI'N NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 ERMIT NO. (206) 431 -3670 Corrections required prior to approval: Date: .4✓/ i/.r - 1 $42.00 REINSPEC ION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. I Receipt No.: Date: Proe r .433. Type of inspection: ,� Address: ? 7 *JO . f'I I. Date called: 3/5/� Special instructions: Date wanted: 7cp ✓?� � l a.m. p.m. Requester: Phone No.: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. COMMENTS: 3 3 5 / q`S /5/h4 q ni WA-1 5 f d C 6 ,yi,dr I Inspector: Receipt No.: INSPECTION RECD 9 Retain a copy with pit $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Corrections required prior to approval. Date: Date: Project: lit d 1 Type of inspe '•n• ..r. 4. -- i Address: Date called: Speci I ihstr n i d s` "- Date wanted: /../.., . H Requester: Phone No.: • INSPECTION O. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. ACorrections required prior to approval. COMMENTS: Inspector: 1 Receipt No.: INSPECTION RECORD Retain a copy with permit ,&/-i? 6.J 7d, )-7 -�" 41.44J... ka77-02p/A PERMIT NO. ``-/ V 36 7 e; ) sc_444 -eh &/ Y3/ - .0409 2_4/4--,s04 /3k6 c, Date: (206) 431 -3670 $42.00 REINSPECTIO t✓ FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100, CaII to schedule reinspection. Date: Pr ect: . Type f ins ` 1l) \v _1ci etr F. Date call d: A l —° Special instructions: DIEnntesi ^' �1t,^ ' ! p.m. ester: • Phone o.: 9' - afl INSPECTION NO. INSPECTION RECORD Retain a copy With permit CITY OF TUKWILA'BUILDING DIVISION 6300 Southcenter Blvd., #100; Tukwila, WA 98188 PERMIT NO. (206) 431 -3670 Approved per applicable codes. f1 — /i Inspector: I Receipt No.: Corrections required prior to approval. Date: $42.00 REINSPEC • FEE - EQUIRED. Prior to inspection, fee must be paid at 6300 Blvd., Suite 100. Cali to schedule relnspection. Date: Pr • ct: Type cf inspectio Ct p — _` �( � C Date called: • Special instructions: - •: • G`� .�Yl D want }}^ q Re e er:. , • Q Phone : J`" , - i 1 � 1 Z ,IFIrdetisaut Imam CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 9818 '1 Approved per applicable codes. ® Corrections required prior to approval. COMMENTS: f $42. ' ' REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection. Inspecto Receipt No.: t INSPECTION RECORD Retain a copy with permit Date: Date: PERMIT NO. (206) 431 -3670 . • COMMEN 4. ` P2 e eita `l ' / "u ,1 0.- � G.,a!/d j !r, F..y `,., . r, a h 1., 4 ✓ frt., / a 2- 4T/j( /.f-'`r'.f C?sr/L ! ' r;)7A...44. , Address (9 Ai°4 ?)Z3Yr r A #--r - 't e► kmeh ri f ak l i- ytag, Date called:// • i"4 L le GcmM ha-- I-4k-o .S,lue "o4'5 g 't i-'io A ti►t-744 —' f ( C (14Z y,.J /- i 9 �51 - f f/ ?c� ava re P c a ;•■• "V v;X, * 1 ,et,te,t- Ghd l - io - Requester: .: Project .— / L.J Type of pection: "'%r. - . .,,, ei. r Address (9 Ai°4 Date called:// • Special instructions. 40_-Z. L,147 ' Date wanted:(^j /7" // , ?7- Requester: Phone No.: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 - Approved per applicable codes. Inspe INSPECTION RECORD Retain a copy with permit M4 Orri-oLy7 PERMIT NO. (206) 431 -3670 Corrections required prior to approval. Date: (1.../4.-(7 $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: P ject: Type of ' spection: 9s�t1 Dl At D calle .,, i ` Special instructions: .a:- -u ` - .e.-- , t \S� r want a.m. (23 Reqqester: Phone N f� �` 7 t•-� _' f INSPECTIpN NO CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 9818 V 1,...4proved per applicable codes: COMMENTS: Date: /er6ty $42.00 EINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100, Call to schedule reinspection, Receipt No.: INSPECTION RECORD Retain a copy with permit al-N(19 PERMIT NO. (206) 431 -3670 Corrections required prior to approval. Date: Pr "ect: • . Typ of inspecti : ' ' c Date calle Special instructions: D wa to a.m. _ ri R ester: N o l �\ Ph n ...rL -�J� / INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 COMMENTS: tit 1 N R �}a S�oc fU.- -t.-1'J O Any V ■I\ tl I( w�MvS1}. A.P P tR.Av.t•"9 • G to - mss nF- r :, c IS LAP iZ t�v�� Inspector: Date: ,11 Approved per applicable codes. INSPECTION RECORD Retain a copy with permit � I ,. • PERMIT NO. (206) 431 -3670 Corrections required prior to approval. $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite Call to schedule reinspection. Receipt No.: Date: Project /` Tyro 1 •- ' • • Addres Q E Date • ••o / s, 97 Date want Special instructions: ,:, ' Requester: 37 ni ,Phone 1 Li . • 61 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved"per applicable codes. COMMENTS: N0i-.- 'c' // Z i .Sflet L .. . X1 L /, ��� --l1 /4 Inspector: Receipt No.: INSPECTION RECORD Retain a copy with permit • 0 Cd2' -e/k vArwas ., NN E 206) 431 -3670 Corrections required prior to approval. Date: / /P7 $42.tf0 INSPECTIO FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: Project: .y �' i t _i Typeze 6 7 •o' n �cal JI Addres Date t Special instrucs: Date wanted: 9_16 _97 a. m. Requester ( A 117 Phon p S5 7 . . • INSPECTION NO. CITY OF TUKWILA BUILDING .DIVISION K,; Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. COMMENTS: Inspector: INSPECTION RECORD Retain a copy with permit q 7�o L t-7 PERMIT NO: (206) 431 -3670 . Corrections required prior to approval. Date: $42.00 RE1NSPECTION FI REDtRED. Prior to inspection, fee ust be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: COMMENTS: �,r( (J� Y�C9! 7:3ce,h , ... I awl 0 / Special instructions: Date wanted:, / I7el'I' l y Requester: / /9-eW 2) 3 -5 ( eplur/ Ja /s/- / - 1;/, 4 0 /- . ,/2L -7t-ii evz„.4..., ,r'e-tx#.4 >, 4 , P70 4- 601,t,..- 7 ) /( L4 (- "W ,Q Project: Type of inspection: Date called: ... Address: J Special instructions: Date wanted:, / a . .m. Requester: Phone No.: CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION NO. INSPECTION RECORD Retain a copy with permit Approved per applicable codes. Corrections required prior to approval. Inspector: - v Date: Receipt No.: Date: PERMIT NO. (206) 431 -3670 Ti $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. ! . Project: (�tG1 l Type of e io : A Add -77 n do Date called: 9 _ rf _ G ! t Special instructions: Date wanted: 1 - 1 2 "'i'1 �1• Requester: 7 Phone No.: /6 0 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) 431 -3670 Approved per applicable codes. • Corrections required prior to approval. $42. REINSPECTION E REQ "RED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: ire COMMENTS: Ty e of inspection:, -� FN LL t +-,E,14( tht.t.S I SO • i / W AvL fl'— F t , in l 9 (, (S ,. ,zA„ w ,i-,,,,9 ht4c, p,A. 7) -C-79ST" (,-;1.41,L.: Orf -SZA14,k ItmA - D wanted: r-� �� «"'� 1 y Re nester: ' Phgne 4 ... L1/4\ t Q Project:. . ` Ty e of inspection:, -� e - co- 9. 1,. D- — —C I ( Special instructions: D wanted: r-� �� «"'� 1 ID p.m. Re nester: Phgne 4 ... L1/4\ t Q • Approved per applicable codes. INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 9818 PERMIT NO. (206) 431 -3670 Corrections required prior to approval. Inspector: ' I Date: C) oiq $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Ins 11 L c0t No.: Date: Project: c ..\ , Type of inspection: • .i w � I 1 Corrections required prior to approval. Address: p 170 A. {• Date called: -11/ Special instructions: Date wanted: ° 1 1 q P.m. Requester: /0 e 4 kr.) S I az or ` c,.t'n Phone No.: - G /4-42.4"A. Approved per applicable codes. I 1 Corrections required prior to approval. COMMENTS: o I -- LAIAUL:S /0 e 4 kr.) S I az or ` c,.t'n f 1"s3 - G /4-42.4"A. i� f INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188\ (206) 431 -3670 I Inspector: II r�l $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. I Receipt No.: INSPECTION RECORD Retain a copy with permit Date: el I' c3 Date: PERMIT NO. Project: Type of inspectioj . / u6V Address: Date called: Date wanted: 7 __ s .....__ 7 / gym `- 7 7 P. Special instructions: "' Requester: Phone No.: - INSPECTIOIQN0, CITY OF TUKWILA BUILDING DIVISION 6300ISouthcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. Receipt No.: INSPECTION RECORD Retain a copy with permit Date: • PERMIT NO. (206) 431 -3670. COMMENTS: A.40,1_,L,4 / Corrections required prior to approval. n $42.00 REINSPECTI v FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southynter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 [jy Approved per applicable codes. COMMENTS: -row-Ida/4 ?)e) p / • 5,e-4 e--z-7 G `!/ C Inspector I Receipt No.: INSPECTION RECORD Retain a copy with permit I Corrections required prior to approval. Date: 1 \. PERMIT NO. (206) 431 -3670 .1 / /L L- ( $42.00 REINSPECTION EE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: ..eL.1e e ed '"\ri Special instructions: to ante �" I - � . p.m. t este_ rA n Phope lsel:5� (4 L INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 [jy Approved per applicable codes. COMMENTS: -row-Ida/4 ?)e) p / • 5,e-4 e--z-7 G `!/ C Inspector I Receipt No.: INSPECTION RECORD Retain a copy with permit I Corrections required prior to approval. Date: 1 \. PERMIT NO. (206) 431 -3670 .1 / /L L- ( $42.00 REINSPECTION EE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: Project: F ` r -'t�+� Type of inspection • ��� -f Address: ' - 77oA.P -�. Date called: -- Special instructions: .j '. Date wanted: •-1 -9 1 . a m p.m. Requester: (+ Phone No.: Approved per applicable codes. COMMENTS: ( Inspector: G � ( I Receipt No.: • INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION Date: 6300 Southcenter Blvd., #100, Tukwila, WA 98188' y r PERMIT NO. Corrections required prior to approval. 4 4 ctZT1 fJ�S Date: - 7-0z4 - 1 (206) 431-3670 $42.90 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. COMMENTS: fins eotion: I -�( y�ci4 pW`''i Die w ted :� t /� r-� t AAc440 A-; 32 6∎G • Special instructions: l _r t2i p .m. Req ester: A X ■Th ( CA..le -1 Q 4 " Phor}l r t ti " -- � C P ofect: A J «.. fins eotion: I -�( y�ci4 pW`''i Die w ted :� t /� r-� e rn aryirw. Special instructions: l _r t2i p .m. Req ester: A X ■Th ( CA..le -1 Phor}l r t ti " -- � [ INSPECTION RECORD Retain a copy with permit INSPECTION NO CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) 431 -3670 Approved per applicable codes. Corrections required prior to approval. Date: 9,h $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection. Inspector: I Receipt No.: Date: P oject: a of ins�p a lio �` n: r, lam .Addri P Daj�cal Special instructions: Dt wo'te a.m. Resster: c INSPECTION RECORD Retain a copy with permit INSPECTIO NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98 Approved per applicable codes. COMMENTS: Get} %4 (Wee ii7.64ze~eq Inspector: 11 Corrections required prior to approval. PERMIT NO. (206) 431: -3670 A i 14/11 Date: `S $42.00 REINSPECTIO FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100 : Cali to schedule reinspection. Receipt No.: Date: Pro ct: a of ins a n: 44" "07' ddrgss: fu..Q PiA cal Special instructions: c3tb .' Dwand a.r m. 48 U) 05 P .. [Approved per applicable codes. COMMENTS: I 1 ,_ ;A. Inspector: I Receipt No.: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) 431 -3670 Corrections required prior to approval. - t)I ! Date: W 'ter ..� $42.O EINSPECTION tE REQUIRED. Prior to inspection, fed must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: Project: --- • Type of in •e ion ,.. Address77 n 0 ilia t Date called: X )/G /(J Special instructions: Date wanted: s1o7 fI / /! c/ ef P P.m Requester: � I ., 'Ls W Phone No.: — )sw l' r'- INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 981 pproved per applicable codes. COMMENTS: r + C ) 4..uq j Inspector: INSPECTION RECORD Retain a copy with permit PERMIT NO. Corrections required prior to approval. o 4 s . e Date: (206) 431 -3670 $42.00 REINSPECTION EE REQUIRED. Prior to Inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: • Project: � .... r Type of inspection Add res • ?t Date called: Special instructions: Date wanted: a.m. Requester: Phone No.: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila;, WA 98188 Approved per codes. " 4/ PERMIT NO. (206) 431 =3670 Corrections required prior to approval. $42.00 REINSPECTION E REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Project: rU , t Ty of inspection 1� Address: 1`113 doti.or PK F Date called: — a i — ql , _ Special instructions: Date wanted: q Requester: � irn Phone No.: 4 - 6a--1 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. COMMENTS: AA—A-- 6 tA-- 125 Inspector: ,c 1 -� INSPECTION RECORD ( Retain a copy with permit 1 1 Date: C)1-03 PERMIT NO. (206) 431 -3670 Corrections required prior to approval. /il.4 $42.00 • EINSPECTIO ,/ REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: tt Project: v.v I J Type of inspection Address: ��O Date called: r� ^ �r `� -t Special instructions: Date wanted: Requester: '11Y1 Phone No.: 5:35(4 . r - INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 9818 so INSPECTION NO. [Approved per applicable codes. COMMENTS: Inspector: I Do-0A PERMIT NO. (206) 431 -3670 Corrections required prior to approval. /71 11.7 Date: $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection., Receipt No.: Date: Project: IU J Z Type of inspection: r .[JUG Address: � AndQU -ef PK E Date called: ��at �� Special instructions: Date wanted: m. Requester: ji m Phone No.: CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 COMMENTS: 7:- (-4 --(31-7 � a-1- /41//t 7 r � /z INSPECTION NO. $42 :tT0REINSPECTIOff FEE REQUIRED. Prior toTnspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Approved per applicable codes. Receipt No.: N SPECTION RECORD Retain a copy with permit (206) 431 -3670 Corrections required prior to approval. Date: t$ it Project: rU • i T of inspection: r� t n CC m Address: 1._1 wOV € Date called: < 6, 1 f q Special instructions: Date wanted: 9 Q—'} m. Requester: Ti m Phone No.: e65 Li G f IIjSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., < #100, Tukwila, WA 9818 Approved per applicable codes. COMMENTS: C.0 rZi � Inspector: i . 1m $42.00 REINSPECTION E REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100, Call to schedule reinspection. Receipt No.: Date: Corrections required prior to approval. Date: 7iZ PERMIT NO. (206) 431 -3670 Project: r U • i ' Type of inspection: r- Camille called: "a 1 a. Address: TO kn ov-eY Pt € Date -Special instructions: ��� ��`�` / Date wanted: ' Requester: 01 m Phone No.: ssi ssai • • INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 9818 Approved per applicable codes. • PERMIT NO. (206) 431 -3670 Corrections required prior to approval. COMMENTS: li en keioo $42.00 REINSPECTION'FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Project: Q Tv e of inspection,..„' mov-e 6 kp (work Address: ,, , ` 1 - 10 INnCIC .4 Pk-E. Date called: -a 1 -- q� Special instructions: Date wanted: � f � a .r q � -p n. Requester: 3--1 Phone No.: 3514 Js zi • COMMENTS: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. INSPECTION RECORD Retain a copy with permit (206) 431 -3670 0 PERMIT NO. .. Corrections required prior to approval. Date: Date: S INSPECTION F REOU1 iED. P rior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. I Receipt No.: Special Instructions: /,/ -/4 7 7 c.- rLL�.-, f.-Kr ft r� -7"c cl�v ,24- ..,.,Abe 15Xer7I.A. -7 7 .l- ce i 4 17/97 A- 4- i e.t 1 .c, c, U E . A (4411' I 0 /fl( 7 S cip0 Type of Inspection: St) g/nafr ) ,(JAJ to.k.g7td1 ST '(... (_ -, wte At 6-1' sct e : 1.n,J U/ q /y 7 ;..3/ Sr , 4.✓ j- v', /,` * e d ,i// /t i4' te14 - 6 Q / QiW A�. e/ Requester : 1 5..,v(.,tAG,. 4 t' ;IV !/ I.a 12e4 -a , g< wAS /1Rrc✓te111 -5 C L -i C/ Project: /-- v( Permit No.: 0 q 7 _ 02 7 Site Address: -776 /iikidooi4 14Air c..-Li Date Called: cip0 Type of Inspection: St) Date Wanted: q /y 7 Fa'a.m. • p.m. Requester : Q,. "�v Phone No.: City of Tg ivila Inspection Request Department of Public Works — Engineering Division Phone: (206) 433 -0179 1 ) 4 ,..14 s rit Ireg c) ((( p ,re flu, .s?1 yo...! / 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 1 itazamJA, .A.R. TESTING LABORATORY, INC. P.O. BOX 2523 Phone: (208) 881- 5812 REDMOND, WA 98073 FAX: (206) 881 - 5441 % ri:} Y. M':; 5/ k•::,•,; Si $'k • rm i<.;th} s�'..�.+•.'a %:.•fart m:t ��}ynt�.„y-,�; .yy,.��{ .::: > �'3�;s"�'<�'� }nom >�:'•�J..n`.',}?�'•:;ft`�$. �;' :o: �: JkS : +:Y }� vni4? . \:.} .•�.•`'.'hti,'•:h i nJ:11t1 } \14.. kk::h.' %j N •.: ?.: . Inspector. M. Jeong Reviewer: M. Jeong Report Date: 9/8/97 Date Mailed: 9/26/97 . . , ' : J3' f:: f'^: ir4};;•:•>•• 4< Ri3,!t t' ::•` {, • �y, 7 ,., 2 ,:+ ; 4 „ 47 .':r:;; ::.. : ,r, .. �.., {nx:•±.C., �t' '�}} .•r C•� J.....t nA, \ v hi,J J nt., 25' y.Y 4•h. } .^Ft• . :F. n:.,...... ... },:n +T..a. •• v?+. ,�•.. .fir. ,••^k•. Job Time: Air Temperature: n• }4 'h i•J:n ;':.ii: }! ? }:j•k:: ?:::k .F. :'t k:• ;,t: :: { {.fik; •%. v,. �.:};%•.t :.f�'•!.a:'•>• +ts,Jy;: :.tJr•`'�•. 3 ?+"k.r {: k},.: {r.: {h: .. E:. ? , { r f;; S• `: ;Y : ;• T. ' { :'�} ?x• ? >:k•::k:.:,. vr, x. L�J, �•. f?,;{: Y.,C;., ,k;;•${.}f,., /;.ft`y., {. ;: ;`3,: • {.:• }: a:: ?:}.�.. �ti <:f£a �' +NSk .. , i .:z3�:� � };k`•v > ?6:r.'`?E:Yt%iti \ "vfzk: • kF. :ikti:#�S:kk: ?kk�`;'•:t•`•kY } t; •L : ,.,,. ,. •,� k :}:'•ri: {a,!•r•> •4:k:+:.'• C wa:•.,:uk:::'Ji: •r: v %; `Ct::.::: J:4kt;:t:+; ?.. $$�� • .n 11 h:kk:+? ?�?•6•:•t.'.•?;.•v..,. .. ,it :r•.`�.'`• ? ?:., t? :• :::..;.; } % {.;.? \•: ?.Jti: �.,•::. t•S.i:•::,,.fi�•f • } ?:'.kk, ,:.... n ... , ,....... Y• ... Yn ..... { ... n .... nr ..... i:i r ...,.... \ .. ........... Visually inspected field welding and HS bolt installations to erect chemical storage steel frame entirety. Observed all erection adequate per plan and specs. Welding conducted by WABO certified welder using E70 series electrodes. • RECEIVED SEP291997 COMMUNITY DEVELOPMENT ALL REPORTS ARE CONSIDERED CONFIDENTIAL AND ARE THE PROPERTY OF THE CLIENT AND A.A.R, TESTING LABORATORY, INC. REPRODUCTION EXCEPT IN FULL, WITHOUT THE WRITTEN CONSENT OF A.A.R. TESTING LABORATORY, INC, IS STRICTLY FORBIDDEN. • 09/16/1997 17:06 12066273060 BERNHOFT & ASSOCIATE fuji tru color frame wall revision Aug -20 -97 03:51P FUJI( 2UCOLOR Please print or type (Form designed for use on elite (12- pitch) typewriter.) a E N E A T O R A UNIFORM HAZARDOUS WASTE MANIFEST Printed /Typed Name 1 9. Designated Facility Name and Site Address EEC RMCYCLIMJ 1824 RAILROAD AVE UX IT. VIflNI. VA 911274 - Generator's US EPA ID No. Manifest Document No. 3. Generator's Name and Mailing Addressruji nocaLoit _ t19Ja1iLA 770 ANDOVER PKWY EAST TUKWILA, VA 98188- 4. Generator's Phone ( 206 ) 575 -M46 5. Transporter 1 Company Name 6. US EPA ID Number 7. Transporter 2 Company Name 8. US EPA ID Number 10. US EPA ID Number a IQ HAZARDOUS MASTS LIQUID M.O.S., HC9, NA3082, PC III, IQ, (D011, b702), (DG171) 0 r 0 C. d. Signature 2. Page 1 I Information in the shaded areas of is not required by Federal law. A. State Nfanifest Document Number B. State Generator's ID C. State Transporter's ID D. Transporter's Phone State Transporter's I F. Transporter's Phone G. State Facility's ID H. Facility's Phone ( ) 253 -18 12. ontainers 13. 14. 11. US DOT Description (Including Proper Shipping Name, Hazard Class and ID Number) Total Unit No. Type Quantity WWol Waste No. C b011,Y'1'aa - J. Additional Descriptions for Materials Listed Above ) PHOTO CHEMICAL WASTE (CONTAINS SILVER) K. Handling Codes for Wastes Listed Above 15. Special Handling Instructions and Additional Information IMERGENCY PHONE : (800) 484 -9300 AMIRGEPCY CONTACT : CHEMIEC 16. GENERATORS CERTIFICATION: 1 hereby declare that the contents of this consignment are fully and accurately described above by proper shipping name and are classified, pocked. marked, and labeled. and are in all respects in proper cond,l,nn for Iransporl by highway according to applicable international and national government regulations. If 1 am a large quantity generator, I certify that I have a program in place to reduce the volume and toxicity of waste generated to the degree I have determined to be economically practicable and that I have selected the practicable method of treatment. storage, or disposal currently available to me which minimizes the present and future threat to human health and the environment; OR, it I am a small quantity generator. I have made a good faith eltorl to minimize my waste generation and select the best waste management method that is available to me and that 1 can afford. Printed /Typed Name Signature Month Day Year 111111 17. Transporter 1 Acknowledgement of Receipt of Materials Printed /Typed Name l Signature Month Day Year 111111 18. Transporter 2 Acknowledgement of Receipt of Materials Printed/Typed Name 1 Signature i fonth Day Year 19. Discrepancy Indication Space 20. Facility Owner or Operator: Certification of receipt of hazardous materials covered by this manifest except as noted In Item 19 Month Day Year 111111 Style CFt z 6 LABELMASTER, AN AMERICAN LABELMARK CO CMICAOO, IL 60616 1800)6275808 fi)PAWICLWAW ••,,,,, tsvw SOrhur .. L 206, 75 1672 P.02 Form Approved OMB No 2050.0039 Expires 9.30.96 EPA Form 8700.22 tnnv bea Pn:wous u0'.or.s ern ooso.cte 770 Andover Park East Tukwila Wa. osi Phone: 208-575-8446 Fax: 206575467.2 •Cornenentss 0 Urgent 0 For Review 0 Please Recycle' TANK # 2. PROJECT : FUJI TRUCOLOR , INC. 770 ANDOVER PARK EAST TUKWILA, WASHINGTON 98188 TECHNICAL INFORMATION FOR MIXED REPLENISHER TANKS AT MEZZANINE (SEE MSDS SHEETS PROVIDED) TANK NUMBERS REFERENCED ON FLOOR PLAN. FILM PROCESSING TANK # 1. NEGACOLOR LR DEVELOPER/REPLENISHER. 6 GALLONS OF CONCENTRATE PLUS 44 GALLONS OF WATER EQUALS 50 GALLONS OF MIX. ULTRA NEGACOLOR, BLEACH TYPE III CONCENTRATE. 5 GALLONS OF CONCENTRATE PLUS 105 GALLONS OF WATER EQUALS 110 GALLONS OF MIX. TANK # 3. UNILEC LR FIXER AND REPLENISHER. 15 GALLONS OF CONCENTRATE PLUS 22.5 GALLONS OF WATER EQUALS 37.5 GALLONS OF MIX. TANK # 4. NEGACOLOR PHOTOGRAPHIC STABILIZER AND REPLENISHER. 96 OUNCES OF CONCENTRATE PLUS 74 GALLONS OF WATER EQUALS 74 GALLONS, 96 OUNCES OF MIX. RECEIVED CITY OF TUKWILA JUL. 2 1 1997 PERMIT CENTER • .• PAPER PROCESSING TANK # 5 EC LR 100 DEVELOPER REPLENISHER. 11.25 GALLONS OF CONCENTRATE PLUS 138.75 GALLONS OF WATER EQUALS 150 GALLONS OF MIX. TANK # 6 ACETIC ACID SOLUTION, 90 %. 2.5 GALLONS OF CONCENTRATE PLUS 317 GALLONS OF WATER EQUALS 320 GALLONS OF MIX. TANK # 7. • COLORPRINT RA BLEACH REGENERATOR. 15 GALLONS OF CONCENTRATE PLUS 105 GALLONS OF WATER EQUALS 120 GALLONS OF MIX. TANK # COLORPRINT RA FIXER REGENERATOR. 15 GALLONS OF CONCENTRATE PLUS 60 GALLONS OF WATER EQUALS 75 GALLONS OF MIX. RECEIVED CITY OF TUKWILA JUL 2 1 1997 PERMIT CENTER . . Nash Rates (General Recommend ■na) Recommended minimum wash rates f" Continuous & Roller Transport Rack & Tank first Wash iecond Wash (Single Tank) iecond Wash (Cascaded Tanks) 3,000mIlft 6,000mVft 3,000mVft 6,000mVft 12,000mttft 6,000mVft Disc 2- 10L/Min • 2- 10L/Min 2- 10L/Min rocess C-41 & C-41 A • if first wash is replenished by countercurrent cascade from the second wash, then the wash rate is identical to the second wash rate. , .ow-Flow Wash Replenishment Rate: 300mVft (where applicable). =film Sizes / Square Footage 'iim Size So.FtJRo!I 10 -12 0.0780 10-24 0.1310 26 -12 0.1770 26 -24 0.3190 35 -12 0.249 35 -24 0.4200 35 -36 0.5920 • Does not subtract space for sprocket holes where applicable. All roll sizes are trimmed to splice. Film Size Sa,FtJRoll' 120 0.5470 220 1.0900 620 0.5300 127 0.3050 Disc 0.0264 'roduct Specifications / pH ( @25 °c) & Specific Gravity (@2o°c) IEGACOLORTM Developer IEGACOLORT" LR Developer Iftra NEGACOLORT" Bleach 3 Ittra NEGACOLORT" Bleach 3LR IEGACOLORTM RA Bleach luntT" Color Fixer 'NILEC LRT" Fixer EGACOLORT" RA Fixer EGACOLORTM Stabilizer EGACOLORT" Prot Stabilizer C® Neg SUPERFLOT" Fresh Tank Qti SD.Gravlty 10.07±0.05 1.03610.003 10.0310.05 1.03710.003 See Appendix #1 4.3810.10 6.4010.20 7.5710.10 6.5510.05 NA NA 8.5010.50 Temperature Conversions °F oC of °C °F °C 68 20 89 31.7 98 36.7 77 25 90 32.2 99 37.2 82 27.8 91 32.8 100 37.8 83 28.3 92 33.3 101 38.3 84 28.9 93 33.9 102 38.9 85 29.4 94 34.4 103 39.5 86 30 95 35 104 40 87 30.6 96 35.6 105 40.6 88 31.1 97 36.1 106 41.1 1.15210.003 1.08210.010 1.11310.010 1.12310.005 0.99710.002 0.99810.002 1.00010.003 3.6510.10 6.4010.20 7.5710.10 6.5510.05 NA NA 8.5010.50 Gallons 0.00781 0.2642 1.0 2.642 5.284 10 12.5 25 1.215j0.003 1.08210.010 1.11310.010 1.12310.005 0.99710.002 0.99810.002 1.00010.003 33.818 128 338.177 676.354 1280 1600 1.0 3.785 10 20 37.85 47.3125 94,625 Film Size Sa 4x5 0.1389 5x7 0.2431 8x10 0.5555 11x14 1.0694 • .3 Repienisher Regenerated So.Gravity Sp.Gravfty 10.1310.05 1.03810.003 10.1510.05 1.04110.003 See Appendix #1 See Appendix #1 Metric Conversions Ounces Liters MLS 1.0 0.02957 29.5703 1000 3785 10000 RECEIVED CITY OF TUKWILA • it t 2 1 199; PERMIT CENTER iiiiiii, FUJI HUNT PHOTOGRAPHIC CH >LS, INC. Product Specifications / pH ( @25°C) & Specific Gravity ( @2o°c) Colorprint RA Developer Colorprint RA Professional Dev. ColorprintliA Developer • • Colorprint RA Bleach Fix Colorprint RA LR Bleach Fix HC 04 Bleach Concentrate UNILEC LR"l Fixer • Colorprint SUPERFLO"' Fresh pH 10.2010.05 10.1510.05 10.1530.05 5.453.0.05 4.8130.20 5.0010.20 7.9030.10 7.50.11.00 Temperature Conversions °c °F °C of °C 68 20 89 31.7 98 36.7 77 25 90 32.2 99 37.2 82 27.8 91 32.8 100 37.8 83 28.3 92 33.3 101 38.3 84 28.9 93 33.9 101.3 38.5 85 29.4 94 34.4 102 38.9 86 30 95 35 103 39.5 87 30.6 96 35.6 104 40 88 31.1 97 36.1 105 40.6 of ; Ni care... Tank Spec.Gray. 1.02610.005 1.02910.005 1.02730.003 1.06810.005 1.09410.005 1.05230.005 1.09630:010 1.000±0.003 Replenlsher pH Spec.Gray. 10.6910.05 1.029.10.0 10.7010.05 1.03010.005 10.7030.05 1.03430.003 5.4530.05 1.06830.005 4.8010.20 1.17910.003 5.00.10.10 1.07910.005 4.9 -5.1 7.95±0.10 1.11810.010 7.90-10.10 1.10310.007 7.50.11.00 1.00010.003 Metric Conversions Gallons Ounces 0.00781 1.0 0.2642 33.818 1.0 128 2.642 338.177 5.284 676.354 10 1280 12.5 1600 25 -- 031.1.037 1100 -1.120 1.076 -1.082 Liters MLS 0.02957 29.5703 1.0 1000 3.785 3785 10 - 10000 20 37.85 47.3125 94.625 CITY OF JUL 2 '1 1997 PERMIT CENTER ^P 1 - , ' % C; ran; 0 433,3 Product Mixed beplehlsheF HUNT'" HCC 404 Bleach Concentrate Varies 817867 Mixed heplehlsheF UNILEC Fixer and Replenlaher 60 Gallon 220 Gallon Colorprint RA Regenerator Bleach 120 Gallon .; RA Fixer Regenerator 75 Galion m 818716 818726 Mixed 1:ieplehlsheF UNILEC LR Fixer and Replenishes 15 Gallon Concentrate 818717 822380 • 83041 33 Om Flam- Personal Part Health mability Reactivity Protection Ingredients 2 2 0 0 n 0 0 0 0 1 0 0 0 O 0 0 '4 0 0 C Ferric Ammonium FnTA Ammostiurn Bromide Ferric Nitrate I'I)T■ 1 lydrobwtnic Acid Sodium Sulfite Water C Ikiric Ann mot durn wrA <5 21265.50-9 Ferric Nitrate <5 10421.411.4 P1rrA <1 1939.36.2 Arctic Acld <1 67.11 -7 IlydrobromlcAcid <1 10035.10.6 Water Balance 7732.18.5 C Ammonium Thiosulfate Sodium Sulfite Water C tuntxdlnn 11thasulfze <15 Sodium Sulfite <5 Water Balance C Ammonium Thiosulrate Sodium Sulfite Sodium Metabiwslfite Water B Potassium Polycarboryllc Add Iron salt Potassium Bromide Potassium Nitrate Potassium Acetate Glycolic Acid Water C Sodium T7tiosultate Potassium Sulfite Potassium Acetate Potassium Hydroxide Water m m HIS Infolm�OA as of April 1995 For additional safety information consult die Product MSDS sheet. For Medical Emergency Cali 600- 424 -9300 Page: 14 (Th Amount CAS# <30 21265 50 9 <25 12124 97 9 <10 10421 48 4 <ID 1939 36 2 <5 10035 10 6 <1 7757 83 7 Valance 7732 18 5 <50 <15 Balance <40 <10 <10 Balance B Ammoedtrnlhiosulfate <5 Water Balance 7783.18 -8 7757 -8}7 7732-18.5 7783188 7757.83.7 7681.574 7732.18.5 <10 12426899.1 <10 7758 02.3 <10 7757.791 <5 127082 <5 79-14-1 Balance 7732.185 Hazards Warnings Skin, rryr..s, mucous membrane and Respiratory irritant May . ubse dermantit Allergic rrnclirm to suites may cause ATM-gory ir. Vans .Corrosive to steel Contact with household or industrial Hleach(Sodium !IWoclalonte) can relocate toxic gases. Skin, eyes, mucous membrane and Respiratory irritant May cause dermatitis. Allergic reaction to sulfites may cau.re Respiratory irritant . Contact with household or industrial Itteacb(Sod/um IlypocWa#e) can release toxic gases 7783 18 8 Skir>, eyes and mucous membrane irritant. Allergic reacrfon 011111'eS 7757 83.7 may cause respiratory distress. Contact with household or industnal 7732-18-5 bleach (Sodium lbjpochlorite) Can release toxic gases Skin, eyes and mucous membrane irritant Allergic reaction 4.s sulfites may cause respiratory distress. Contact with bou:te- bold or Mdustrial bleach (Sodium llypocblorlte) Can rdaas toxic gases Skin; eyes and mucous membrane irritant. Allergic reaction tose•I/i. may cause respiratory distress. Contact with household or truha;Mal bleach (Sodium Hjgochlorite) Can release Iaxic gases 778 }18.8 Skin, eyes and mucous membrane irritant. Allergic reaction to 7732-18 sulfites may cause respiratory distress. Contact w #b house- hold or industrial bleach (Sodium Ilypoeblorle) Can rdeetse • toxic gases Skin, eyes, mucous membrane and respiratory tract (rritatirn Prolonged or repeated skin contact may cause dermatitis. Corrosive to steel. To Order MSDS shoots or HMIS labels Please call 800-526-0851 Ext. 10 For Chemical Assistance Call 800- 526 -0851 <15 7772-98-7 <15 10117-38.1 Corrosive to all tissues contacted. Mucous membrane and <10 127.0802 respiratory tract irritant. Allergic reaction to sulfites may cttu;e <10 1310.58 • repro Cory distress. Balance 7732.185 ( MWgMUmre4iseam6 JEJIUL_E.!ILIILY: MIXTURE AS-JijAl AOT ASSIGNED/MIXTURE e73: CV1ICAL SAFETY GOGGLES 'WI HUNT PHOTOGRAPHIC CHEMICALS, INC. JEST 115 CENTURY RD. • P.O. BOX 988 ARAMUS, N.J. 07653-0988 ATALOG ';';00041 PAGE: 1 OF 6 7 - ATTN: Ai lEWT;JN FUJI T:-IUC0L0P PHOTO, INC. 13320 1. FIr.ESTGNE BLVD. SANTA FE SPRINGS CA 90670 . . SECTION-1 IDENTIFICATION '4E1 CDLTPRINT RA FIXER PEGENERATOR (CT-319) H`"E.Itd. NJA: 0 HOTJGRAPHIC FIXER jEjICAL_ET:EmULA: .MIXTURE dEllif.I.L_2:5CLIEILLitll CLEAR, AQUEOUS SOLUTION ij FUJI HUNT MATERIAL SAFETY DATA SHEET EMERGENCY NO: 1-(800)-424-9300 INFORMATION PROVIDED BY: FUJI HUNT PHOTO CHEMICALS, INC. PARAmUS, N.J. 07653-0983 TELEPHONE: 201-967-9603 DATE ISSUED: OCTOBER 15, 1993 DATE PRINTED: MAY 19, 1995 REF: FH047 ,,,,,- *:' , m*et*****i,******1:4:4******************************** , xxg****** SECTION -2 NORMAL HANDLING PROCEDURE SELLULP"': T. lj dAtICILILL_AtiLLIOEAaEl AP.mPJL IF SWALL.JwFG. AVOID CONTACT WITH EYES, SKIN OR CLOTHING. UPON CONTACT ITH SL 4 71P EYES. wASH OFF w1TH WATER. AVOID dREATHING MIST OR VAPOR. STORE IN COIL, TY, 4ELL VENTILATED PLACE. AVOID CONTACT WITH STRONG OXIDIZERS AND LKALIc.. HAVE AN 'EME<GINCY EYEWASH AND SAFETY SHOWER AVAILABLE. :cdt';IcAL, EXHAuST VENTILATION RECOMNENDFD TC MINIMIZE EMPLOYEE EXPOSURE P-2008 - ictLTH: 3 7-LAimAIILITY: 0 .cEACTIVITY: 0 PROTECTION: C - - 1E‘L11: 3 FLAZ.mAHILITY: 0 REACTIVITY: 0 SPECIFIC HAZAND: COR c74. )C':* A**1464 *); . =UJI HUNT PHOTOGRAPHIC CHEMICALS, INC. JEST 115 CENTURY RD.'. P.O. BOX 988 'ARAMUS, N.J. 07653 -0988 6SIL_•'"LIEEJLLi POTASSIUM1 SULFITE S_J0A: 10117 -30-1 ato_?FL_ ',ONE ESTABLISHED 1SIC_= ^_I:: =IdL: WATER 772Z-1'; -5 E STAaL I SHED �',• '••J.'IE ESTAhLISH=D E STABL I SHED. ' -2008 &:IC_IJzI= .IALi • SODIUM THIOSULFATF L5.2410 7772 -98 -7 5119_ = =L: NONE ESTABLISHED "4'1 DATA LC_U_ NO DATA iQUIEIL:_!I_EEEECIS: SKIN, EYE AND MUCOUS MEMBRANE IRRITANT. EEEC:UI: 10-154 3:IC_M "-I_EILL_ POTASSIUM ACETATE IS_ Q . 127 -08-02 EZELE►J`LL 5 -103: ib+I_EEL: NONE ESTABLISHED )_ %Q_ 3250 MG /KG (ORAL -RAT) LL_SQi NU DATA IS:i:IItIL= >aI _EEFECIS: SKIM, EYE AND MUC5US MEMBRANE IRRITANT. ASIL_AIE ..L L: POTASSIUM HYDROXIDE _:_Li_'u 1310-51-3 EEELia: 5 iYi.3__iL: 2 MG/M3 CEILING 3(:5 .1G /KG (U: AL- AT) LLSCQ: NO DATA :CLJiti:L.I_EEEECISi CORROSIVE TO ALL TISSUES CONTACTED. EEELELbIL 10 -15 4 EEECEUI BALANCE LC_ NONE E ST. L L I SHED FUJI HUNT MATERIAL SAFETY DATA SHEET ATALC)G 'J 9O0041 PAGE: 2 OF 6 EMERGENCY NU: 1- (800)- 424-9300 • SECTION -3 HAZARD INGREDIENTS :t;: , <x;' < e.'t* Q1.;::;:** !; * t•:aeae **** *:,eY,: ** .• *0' e:, <* fie to *ke *:;e:e**, ** * *** *SRI': !2_SQi N) DATA LL_541 NO DATA i�LIEi�1 " FFFFia: SKIN, EYE, MUCOUS MEMBRANE AND RESPIRATORY IRRITANT. LLERGIC REACTI'JN MAY CAUSE RESPIRATORY DISTRESS. *•••:' +t •.:• • :r :=r.y,eo •d 'ley:;r:.`• % a7 rrec,:t'e:,:Y;*.: *iti,e *:#0,(4s**elt:(r'*ipho;Pize,geggi A�O�f�. +i�:� +' fra fiisi• ` al'id?Y�A,',3to�La*'2: {ac::�nw Kwv 41, is. u.:.ua...,.. ,.,...,........_......�. ................_... .r._ ........................... ............. w... ............,............,..... :UJI HUNT PHOTOGRAPHIC HEMICALS, INC. /EST 115 CENTURY RD. • P.O. BOX 988 ARAMUS, N.J. 07653 -0988 ATAL ! :'': 31)0041 PAGE: 3 OF 6 MATERIAL SAFETY DATA SHEET EMERGENCY NU: 1— (800)- 424 -9300 SECTION —4 FI!'E AND EXFLUSION HAZARD DATA c: ,: r :r,: .s; :i. :�t1 ..:i:rc::$:a; tY :c s•:�:a•Y: .rcrr �� r:rca,:r;ras:zr:i- 4:NsF %F%�t ; tr' c >fat:'::,r >c:.:fifrytac ;.a4'}t: Ito :k�t�caM► L�E_!_L'JIL�I t NOT FLAMMABLE - L_. Eis_ N/A UE2_8L N/A WJT REGULATED (NON—IG`JITABLE) V . ) FUJI HUNT IIj:Is;In_;FjjA_ CHOOSE EXTINGUISHING MEDIA SUITABLE FOR THE SURROUNDING 4TERIALS. HAL II_EaluDu?E: WATER SPRAY SHOULD BE USED TO "JUL F PE _Xr SED CONTAINERS AND/OR DISPERSE UNIGNITED VAPORS. USE NIOSH /MSHA PP EVE[ =' i SITIVE PRESSURE SELF—CONTAINED BREATHING APPARATUS WHEN ANY MATERIAL S INVOLVD I'1 4 FIRE. • :,s.:r;:;ficii: sc:fs4:, :s .t* **v:,: itsFrciftr:,,;,. * ic *a,. tj,::,;s,.:jr4:s,L•*r!:;cs^s' tic: jcs!< I, cf !:*:xa!t** * {• SECTION -5 HEALTH HAZARD DATA „csr : '.� :st:t:; ,:sr:a;<acaci :..1q ; s!c sc sts;C:,c 't:;csr+lc** **xPsr* **4. **Y:**.ixa;:* sic:, fskic.r j c*rc *s!:***s{ts(ctQt*****2. :E.5 2L2_LIAII_YLLn_s NONE ESTABLISHED FOR :MIXTURE. YmPIJ_'5,_ CORROSIVE TO ALL TISSUES CONTACTED. HARMFUL IF NGESTFD BASED ON COMPONENTS. MUCOUS MEMBRANE AND RESPIRATORY IRRITANT. ALLERGIC EACTICN TO SULFITES MAY CAUSE RESPIRATORY DISTRESS. t'EELEL :LY_EILI_AjLI_E2CL:DL3L StJ_ IMMEDIATELY FLUSH 1JITH COOL WATER FOR 15 MINUTES. CALL A PHYSICIAN. YEL: I FLUSH WITH COOL WATER FOR 15 MINUTES, CALL A PHYSICIAN. LlLi =II' :.t_ It!N+1EDIATELY DRINK LARGE QUANTITIES OF WATER. DO NOT INDUCE VOMITING. ALL ; - WYSICIA.N. �LaLc.TI,�L:s I'•+'IEUTATELY REMOVE VICTIM TO FRESH AIR. CALL A PHYSICIAN. . .i � ;�. . �.. r:.,: srf:;: a: s;: r;: a;.: �•,. s: �• r' c'c' rq: a,: a,::: c: f: ita�.: ;cis<s�� :acs,esksi: <: <a:•' >:: i9•ai :ha;r,;t i s' a'sz�alr sk9c�t: v�• Nr � %F�f�'+� r %f of f f F *��� , k SECTION -5 TOXICOLOGY (PRODUCT) i•.. .'c:.. .:s:i' :;: :'car :t:,:r;::4 < idrics'c y:;� ;•s ca'r tr cyc:'t a;< a'c 1t i . k >f�c ;'a;' %f* �:� icy. s::`;:. � . '•'Y� fr('cK ;cif ;: :f ar ,<sYJ,cscJ h :;c _ NO DATA FOR ;ILXTUME.HARMFUL IF INGESTED BASED ON COMPONENTS. :HIr ry : "LL_L:!_22_ NO DATA FOR MIXTURE LL_:121 NO DATA FOR MIXTURE N'JT r NOwN TO L.E CA IAi ;C:'iO [1SHA:Nt -1 I (S) : !T:.r; 1y_ ;46T folu,a! TO DE MUTAGENIC : ": CflP' <OSIV ' -2008 �,!�L�� E F� y'?- 7�•Y1� tiff:.! � r'.tYe`: /.t...'Riw u..1•N!•v..i•inx•hvun:. ✓:.n.. FUJI HUNT MATERIAL SAFETY DATA SHEET :ATAL:G `41: 00041 PAGE: 4 OF b EMERGENCY NO: 1—(800)- 424 -9300 FUJI HUNT PHOTOGRAPHIC CHEMICALS, INC. WEST 115 CENTURY RD. • P.O. BOX 988 PARAMUS, N.J. 07653.0988 CORROSIVE -_'_ lL _a''.L_:sUUILS_DE_A2S2aELLOt:I DERMAL CONTACT, INHALATION, EYE CONTACT, INGESTION �EEE�T_�E_�f CORROSIVE TO ALL TISSUES CONTACTED. RESPIRATORY I,:fF ALL::RGIC REACTION TO SULFITES MAY CAUSE RESPIRATORY DISTRESS. f.EEEcI_2E_E'J: U:1Lc_EIEISIEL? REPEATED CONTACT MAY CAUSE ALLERGIC SKIN REACTION. .:k: :ie: .: ,•, s: + :s-: i; >,i:;:d• ,: “: s'(:;: aF ricic cYcY,: i, :>':i:►;: >s;',c>j(> •>'(:;( s,:: z:?>, cr:> sFtic :Fseak:t!ye>,t*>k*>'cic1'sc* SECTION -7 SPILL OR LEAKAGE PROCEDURE (CONTROL PROCEDURES) i4 .:, :s :s, :,:.. r'c r es'c*f :c :,c>!: ;::c>'t** *tiisk>.cs;: s;t i >;:sc i :;c f=. s 4 c f :,::;::y*cf * *if * * *rF * ***ai(* .�LIi;1 "_r_F] _JAIEElbL_FELEaSz_?E_SEiLLi -f)? SiI4LL INCIDENTAL SPILLS AND LEAKS, WEAR CHEMICAL SAFETY GOGGLES, AND • GLOVES, AND APRON OR COVERALLS. FOR LARGER SPILLS REQUIRING EMERGENCY 3 .ESPENSE, NEOPRENE ?ODTS AND RESPIRATORY PRt1TECTION MAY ALSO BE REQUIRED. FOLLOW JSHA REGULATIONS AND NIOSH RECOMMENDATIONS FOR RESPIRATORY USE (SEE 29 CFR 1910.134 Ai 4D NIf1SH PUP. 87 -108) AND EMERGENCY RESPONSE (SEE 29 CFR 1910.120). ISOLATE AREA OF SPILL BY DIKING. STOP SUURCE OF LEAK. ADD DRY ABSORBENT. CLEAN JP AND PLACE IN AN APPROVED D.O.T. CONTAINER AND SEAL. WASH ALL CONTAMINATED :L'JTHIr:G .EFORE REUSE, AND DISCARi) CONTAMINATED LEATHER SHOES. >!: :d ::t ..0 ::i* ,..:•r: *41. e:,:*:f:4*ie :;eY,c >;gi sts;Ert> ip ; ce; *% tie *,:z o!s;( *, SECTION -7A SPILL OR LEAKAGE PROCEDURE (WASTE) ;:(:i : -•'cf:.'' ;ci• ;c>;c>i is y�c*< < :k:ksc:f :t: r, >' �• • �• F .•s,• � � <�{' , <:{:i,:>ftk�Kklc�if�;ci,: >;:: kic>; c:} c,, �it> a cst: ,c> F **>frc:(ctc*:t***>tsQ:: IASIE_DILEZ.SBL_JEILIULI )ISPOSE 3F CONTAMINATED PRODUCT, EMPTY CONTAINERS AND MATERIALS USED IN CLEANING JP SPILLS OR LEAKS IN A MANNER APPROVED FOR THIS MATERIAL. CONSULT APPROPRIATE :EDE?AL, STATE AND LOCAL REGULATORY AGENCIES TO ASCERTAIN PROPER DISPOSAL , ROCE)UKES. :�% ;> , .... : ; :;:sc .:'•v'csc:�:c, :u:c'c�c t.}. �c:;tu c c :Y.:r :?c> :i <:k >' :f(>':* . ti `• �f f sc>; :i:ic.s,.r•>i; >• >,.s!.:,c ; i�:> fa: sF: cs': f,:!(. t:; •:�;sk�c�:3c��!'�sKn��r ::�(s3:> SECTION —d SHIPPING DATA ..,. ,< ,. :,c .fesa>; :s'; >;e ;c:!e3: . �: if.es;e>'cr;c.�e:�a'r>;::;e�•:; tic:' ti:>, ti! s:s' a ;e :F:,: >i�k�::h(>;t>h:j:s! :�:ns !CI__LLSS3 11RROSIVE LIQUID, N.D.S. (CONTAINS POTASSIUM HYDROXIDE) UN 1760 DI_SI_IE_rI_ "JOT APPLICAJLE s'rai•- : <, s :, ':>,.e,::'e c r.. t•t ,.e,* ;,e•" *s'.s;:i!* st:ie,,;eti(.',((4r;e *, ;e* **3 :t . .>;r:,cY.:.;eieite>r:;ujia < :jt tie:i*>t * *iF>f *sS SECTION -9 REACTIVITY DATA ;• s,:.,c .;,c::sc:k:�e�i ^c. :r �'ei,csfs4:�i• �cie:;r.es't3:sf:f:i�: rests; Cir�c: es; c�cyci:: �;;(: a>;::; t:,: isrfati;: ; < ;� II.:ILIIY a'A L :_ X S1USI LILE_ ALL 61:.'' :. ►.:L�.,�::LY�t;�iZ..ILL 1_ MAY_IJECUc_ kiiLL_JDI_L'DEU .. x i1JLlIl :1� T H Lk/J.I:!: EXCESS HEAT iJC.:_'E ^IT TLiIYi. STRONG ACIDS 4 ?,1 �t.!!s ► E:��lll(lh: Pr LI: SULFUc DIOXIDE P -2008 a5EEE5 UL M/S p IZESEFEL EALIEELWEI FUJI HUNT PHOTOGRAPHIC CHEMICALS, INC. VEST 115 CENTURY RD. • P.O. BOX 988 'ARAMUS, N.J. 07653.0988 IATALO'.; i300041 PAGE: 5 OF 6 P-2008 FUJI HUNT MATERIAL SAFETY DATA SHEET EMERGENCY NO: 1-(800)-424-9300 ::,""';' SECTI(JN-10 PHYSICAL DATA .ELII.LJI1 . JOT APPLICA5LE .EELIEIC_ilLIYIIY: 1.27 1) L2LLEILIIL_IJ_ILIIE: COMPLETE ELLIILLi1 ttr"-!LXIMATCLY 70X LP:L_Da"cin DATA (AIR = 1) - ;....%v3 , e62:::::.1**4-if***************eA******4%;:c*************2 1 13! ,:.ijiti SECTION-11 CANADIAN ADDENDUM HYSICAL DATA Q0E: "...:DCQLESS 2 NO •TA < 0 DEG.0 ZN5iTY: 1.27 JEEE1:1:JI _ JE _ t.:3 DATA IRE EXPIASIJN HAZAK.0 UIL=1.11LLI1 IELELIUial NG DATA _ I' ":1:1AUILAL-IUPALII NO DATA - NO DATA 1 XIGiL:GICAL L-"TIEb FP S;7CTIUNS 39 - 5 .0 t. 2UILIUL-ECLIII> 212 F YAELR PPFSLUEE: 17 MM HG ELLEALICal 12.90 :11 APPROXIMATELY = WATER = FUJI HUNT PHOTOGRAPHIC CHEMICALS, INC. VEST 115 CENTURY RD. • P.O. BOX 988 'ARAMUS, NJ. 07853-0988 ATALJG .300041 PAGE: 6 OF 6 LJN KNO;,N. OR "EPORTED. P-2008 SI -m FUJI HUNT a MATERIAL SAFETY DATA SHEET EMERGENCY NO: 1 - ( 800 )-424-9300 • CiR' :EPORTEO: * /X* * 4 J.! * '3 7 ** 3 . 4 *** 1'induct HUN t'"' IICC 404 Meech Concentrate Va Mixed be tile hit heF Mixed heplehlshei• UNILEC ea Fixer and Replenlsher 60 Gallon 818716 220 Gallon 818726 n z m 23 817867 UNILEC'" LR Fixer and Replenlaher 15 Gallon Concentrate 818717 Mixed beplehlsheh Colorpolnt RA Beech fiegenoretoe ( X20 Gallon.; :. � 822380 Colarptinl RA Fixer Regenerator -o 75 Gaiion) 11 1 800041 t 1.1111 1'ur'.r)n.11 1 .u1 Ittalllt Inabtbly 1111,Yilvtsy I'rolix:lam Ingrotitnnl'' (1 (1 2 0 0 3 0 1 0 0 0 0 0 0 0 0 0 1 rut. Annu..mun. P1)) A Auunnnnun llmrnulr 1rrnt Ndralr I'M A 11).(1n A< wl '+.luau Sulfite. Walrr f✓ Ferric Mutaadun% Ferric Nitrate 1'IIIA Acetic Acid Ilydrobrotnic Acid Water C Ammonium Thioaulfate Sodium Sulfite Water C Ammonium 11►ioeulfat! <15 Sodium Sulfite <5 Water Balance C Ammonium Thiosulfate Sodium Sulfite Sodium Metablsulfite Water B Ammonium ihiosulfaoe <5 water Balance B Potaaalum Polytarbor 4Ic Add Iron salt <10 Potassium Oromlde <10 Potassium Nitrate <10 Potassium Acetate <5 Glycolic Acid <5 Water Balance Sodium 11Jawlfate Potassium Sulfite Potassium Acetate Potassium Hydroxide Water 1�1 Antnun1 CAS a -p) 71745 • 25 12121 91 ') <I11 II1 21 its 4 • 1)) 191') 11; 2 • 5 114)35 111 ti 1157 85 !Wan( r 7732185 <5 <5 <1 <1 <1 Balance <30 <15 Balance <40 <10 <10 Balance 21265 co.? 10.121-48..1 1939.36-2 67.11.7 10035.10.6 7732.18.5 7781 18-8 7757-83-7 7732-18-5 7783 188 7757.837 768157 4 7732.18-5 124268 99 1 7758 02 7757.79 1 1270B2 79.14.1 7732 18 5 <15 7772 98 7 <15 10117.38 1 <10 12708 02 <10 1310 58 Balance 7732 1B 5 11;sz arllt: VV ;n rur)(s \k't t)r't, mtu Ina) nor +n l'ratte a hral•tnits)ry IVnLnd, ►say . .11.u• IG•nn.rnttt A1lrg(u MSC !Urn In u, fri may r.ncte b'tyvmmery or 'twit l or rnurr to steel f'o'Itatt tooth ht'ulrhnhi nr lrtrtuttrt +l Nlr•rtth(.Riduam ll).lrxhkinte) cant n•4sue atvc gates. Skin. eyes, muenus membrane and Respiratory Irritant. Al). cause dermatitis. Allergic reaction to sulfites may c,ru le Respiratory Irritant . Contact with bousebold or Industrial Rleacb(Sodium Itypocbksrite) can release toxic gases. 7783 18 8 Sbrs, eyes and mucus membrane irritant Allergic reaction to 7757 83 7 may cause respiratory distress. Contact with household or irutu al 7732.18 5 bleacb (Sodium I s"yfaochhrite) Can release toxic gases rn ',, m11MIS Information as 01 April 1995 For additional safety information consult the Product MSDS shoot. To Ordor MSDS shoots or HMIS labels Pions° call 800.5260851 Ext. 10 For Medical Emergency Call 800- 424 -9300 Page: 14 For Chemical Assistance Call 800- 526 -0851 Skin, eyes and raucous membrane irritant Allergic rrvactio t.s sulfites may cause respiratory distress. Contact wtsb boo :te- bold or industrial bleach (Sodium Ilypocbiorle) Cars rite toe toxic gases Skirt, eyes and mucous membrane irritant. Allergic reaction to stf. may cause respiratory distress. Contact with bousehofd or inc6artrial bleach (Sodium 1 ochbrite) Can release taric gases 7783 Skbr, eyes and mucous membrane Irrfant. Allergic reaction In 773218.5 sulfites may cause respiratory dlsareis. Contact with bouse- bold or industrial bleach (Sodbass llypocbiorile) Can rdes;se toxic gases Skin, eyes, mucous membrane and respiratory tract Irritator n Prolonged or repeated skin contact may cause dermat Corrosive so steel Corrosive to all tissues contacted Mucous membrane .snd respiratory tract Irritant. Allergic reaction to sufftet may tins ;e respiratory distress. 'UJI HUNT PHOTOGRAPHIC CHEMICALS, INC. 'EST 115 CENTURY RD. • P.O. BOX 988 4RAMUS, N.J. 07653 -0988 ATA.LOG ItO: :)223a0 PAGE: 7'):)4')70': - =TT•:: JI0 , EOTCN FWI T ?UCDLUI PHOTO, INC. 1i320 .c. FIRESTONE BLVD. i°1 ' S�k`? ts..^+ 1fiY. ct+ Rmnxrxrwu.;. a...,+:.... w,...v., r.,.,...»............,. »,ti._.,....�........�........._ ..« ..,w..,..,,............_...,... ....,.,..a...... -., M..... �ww.... ......,.....y..._....�..__._.._ 1 OF 6 SA`!TA FE SPRINGS CA 90670 73 1 1 FUJI HUNT MATERIAL SAFETY DATA SHEET EMERGENCY NO: 1— (S00)•424 -9300 INFORMATION PROVIDED BY: FUJI HUNT PHOTO CHEMICALS, INC. PARAMUS, N.J. 07653-0988 TELEPHONE: 201 967 -9603 DATE ISSUED: NOVEMBER 10, 1993 DATE PRINTED: MAY 19, 1995 ; P,- " :, :c ,:, • •-ei <atq : **2%.:e *frsje , t*s :r :'es;:ii:;t:; FCC:(:'e :!ticsG:*:(':;tiFs;rsy:-ks'!r :>; ever ::st:ft********* ** ** SECTION-1 IDENTIFICATION . .mi•v •5: ._:u:; :s * *eAr'e4* 2. 0eX: i. v*x, iic9psc *+,is;rat**sk*:$:*:(t>, *** eta! e; t:{ t*ski,'t*sF:t*y:*s(e*t} ** * * * ** ** CAORPRINT RAPID ACCESS BLEACH REGENERATOR j% J..1E: PHOTOGRAPHIC ELEACH REGENERATOR (TRADE Ta:IALED AS CT-320) REF: FH091 JEJILL L_ELJ1LY_ ;1IXTURE JELILAL_E ELULL_ •MIXTURE JE!•;ILAL_LEs. IEII _): CLEAR, GREEN— YELLOW, AQUEOUS SOLUTION WITH SLIGHT VINEGAR .IOR 15_UDi.. NUT ASSIGNED /MIXTURE :, :; , :'ci :* *,. <:•:tHci:-{e:; A4:::! ts; c*ifs;:**,: t: t. sk: tc*itskie spe sk*sh*sk**** *** *>;t:fc:(cit*i:s',t:!t* jet(rt*itsrc*>it*#**** c SECTION —2 NORMAL HANDLING PROCEDURE cs'•:s' , ":,A.; , :tyr t *Y-- *,(* e:,t:it;:ses(• } *s; *=;e:t*s!ct! *2:4 g4iltd ttj <s'rileyleel!t**i;<ifit* eie>,t**iesjt>jcati a **4,tfe*****irtjt*** :n:HFUL IF SWALL3WED. AVOID CONTACT WITH EYES, SKIN OR CLOTHING. UPON ITH SKI?I I1P EYES, WASH OFF WITH WATER. AVOID BREATHING MIST CR VAPOR. :0'.;L, (', ?Y, WELL—VEtITIL4TE0 PLACE. AVOID CONTACT WITH STRONG OXIDANTS, %SES AND 7H'J : ;F'HATE CONTAINING COMPOUNDS. CONTACT STORE IN STRONG .JI= jT•1YE_E�1Lc���vT ChE'•IC.1L SAFETY GOGGLES [�LIi ';:;T ' :. .•TALLY RE !CAL " C 1A: {ICAL EX;ii,UST VEWILATIJN RECOMMENDED TO MI•JIMIZE EMPLOYEE EXPOSURE .13 '1E- .LT,I: 1 FLAIIMASILITY: 0 RE4CTIVITY: 0 PROTECTION: B .£A — FL.I*IASILITY: 0 kEACTIVITY: 0 SPECIFIC HAZARD: : ..:t: .. • c:: •;a::f::i..' ,'.ac,'• •s .i:r! i:.;:I )'!:;es t iti r i ca :t,::s;ttt��>sr►;: k 'cserc e:} c sryrdc cu *txi� �t #itsksk * *t1'ie s :UJI-HUNT PHOTOGRAPHIC CHEMICALS, INC. VEST 115 CENTURY RD. • P.O. BOX 988 'ARAMUS, N.J. 07653-0988 aS_:1DA: 12426m-99 -1 ASIL_11AI =aIALI POTASSIUM t3ROMIDE 11S-Lai 7758-02-3 SJA_ESLI NONE ESTABLISHED ASIC_nIF?IAL3 POTASSIUM NITRATE AS_J!Ai 7757 -79 -1 ib ©_e = NONE ESTABLISHED aSIC_�'3I:5I3 POTASSIUM ACETATE 1S_'_'l0a . 127 -0:3 -2 it.J_EELL NONE ESTABLISHED `+ATraIAL: GLYCOLIC ACID :i_: : 74-14-1 :JL_CIL? '1Pubt P3TAcLI SHFD 2 -2008 r MATERIAL SAFETY DATA SHEET ATALOG '4f;: 822360 PAGE: 2 OF 6 EMERGENCY NO: 1-(800)- 424 -9300 SECTION -3 HAZARD INGREDIENTS wic ;. ; r: ; i s ,: ir'•:• : ‹et t; p rieiese*ot**.A rAie:k ;!* *3 ** aye *i:! c ** ** ** * ** *it7k **** *%f ***** ** * * * * ***,. .4SIj_fA_gIE =ILL: PUTASSIUM POLYCARBOXYLIC ACID, IRON SALT 3015 MG /KG'` LL_Q. NO DATA (ORAL-RABBIT) <IN, EYE, RESPIPATURY TRACT AND MUCOUS MEMBRANE IRRITANT. ARr1FUL IF INGESTED. 2ELLEN : 5 -10% SJA_ELL± NONE ESTABLISHED N1 DATA AVAILABLE LL_50= NO DATA AVAILABLE ILNIEICAUI_EEEELIS_s SKIN, EYE, RESPIRATORY TRACT AND MUCOUS MEMBRANE IRRITANT. AY CAUSE DERMATITIS. EEELEJI? 5 - 10% L_QL NO DATA LL_EQj. NO DATA ILUIEIELII_EEEELISi SKIN, EYE RESPIRATORY TRACT, AND MUCOUS MEMBRANE .RITATIUN. MAY CAUSE DERMATITIS. EE3LENI1 5 - 10% 2E3CEJIi 1 - 5% .� ! `= 1 FUJI HUNT 3250 MG /KG (URAL-QAT) LL_SLi NU DATA AVAILABLE rStaEjC_ SKIN, EYE MUCOUS MEMBRANE AND RESPIRATORY TRACT IRRITANT. %2MFUL IF SW \LLJAED. EE CLSI_ 1-54 :.::iM 3r> u:`,`'• iP' b'.' if,*. i' �• rftt•:1�ti.,`':i�.^�:�v:S;�ii�: .ASi:__��IEEi6L� riATEk 7732-1 !Stir�_2EL_ '40NE ESTABLISHED FUJI -HUNT PHOTOGRAPHIC CHEMICALS, INC. NEST 115 CENTURY RD. • P.O. BOX 988 'ARAMUS, N.J. 07653 -0988 ,ATALJG `46: 622380 PAGE: 3 OF 6 .1..Z1 •IG /:CG (ORAL— LL_ELs NO DATA AVAILABLE :ILJIEIs�;:`!T pr-F_LI : SKIti, EYE, MUCOUS MEMBRANE AND RESPIRATORY TRACT IRRITANT. NONE ESTAbL I SHED ,ISUIELLi,Ji_EEEELIE3 NONE ESTABLISHED .a,�y.ar , ,:e.. za,,s' :i : t :!e>F +.:y- a;::'e:ka;::;ei':ira� �t:,• ;:�• > ;< � s' �' �- . .tak # #��•%� #�_� # * #�* :4 r :F Y >;:at'l��,tafi�:sje r�- :t sbcatitatrf_tiea' sit :(es4t=K: SECTION —4 FIRE AND EXPLOSION HAZARD DATA i:.:s• :i .0 ::;:' to; ca:s!.*,A,' e,: s' v.%, t* ai*Itt:y :4,4s4:!e•J,titst:!e:y *A2 :,* e::aka saea; **it**afajt>It*ak*taJt* **; .LASti_E1iLI_JFIbW23 NOT FLAMMABLE .LAiJAEL= _EILLaSIYi_LIEIISi - L01:1E3s. N/A :5�6_ELa�= IEiLAIIU�3 IOT REGULATED (NON— IGNITABLE) .xIIJSUISJi:1a_i1EDUA_ WATER SPRAY, DRY CHEMICAL, ALCOHOL FOAM OR CARBON DIOXIDE. EECIAL_ EIZ5,_ daL Ee_ti_FIEL_EILUIIVQ_E3[1LEDUEEI WATER SPRAY SHOULD BE USED TO :OOL FIRE EXPOSED CONTAINERS AND /OR. TO DISPERSE VAPORS. USE NIOSH /MSHA APPROVED OSITIVE PRESSURE SELF — CONTAINED BREATHING APPARATUS WHEN ANY MATERIAL IS NVtJLVED IN A FIRE. , ,%0• : ;: ; +':•.t =,. :.::. f4A*v: , =t>;t:;t*:'ta• ,!= �. _$ ,t rs'• a! t; ca; tset i t= l�csxr(< a�: r•,,. xt: kxe*sie={ cs¢: sfe: 8t*skat**skafc*ic****sjc***f**#**x SECTION -5 HEALTH HAZARD DATA , r :; :v c: ,,: ,, :•( s`:'c 0,, `::fA \qc* :; a : A c =h ?'caaa lo* tip.:^•*** c � � �% ��� # � *=t ,- # # * # #�k��� ***: aestl ,:atacs; =srrc #**#*=1e ** LIPEal DLL_LIUII_YLL1E? NONE ESTABLISHED ILIEIU►_L__E_IY:::_= lLESUEy_ SKIN, EYE, MUCOUS MEMBRANE AND RESPIRATORY TRACT RRITATI11N. _i_;��r SI_AIL p3L`L.:DLfsJ:S 11:J: IMNEDIAT =LY FL'JS:1 WITH COOL WATEk FOR 15 MINUTES, CALL A PHYSICIAN. yES_ Ii.=DIATELY FLUSH WITH COOL WATER FOR 15 MINUTES. CALL A PHYSICIAN. JL`cri_ IH CASE CF INGESTION; INDUCE VOMITING UPON MEDICAL ADVICE. CALL A 4YSICIAN. I'ir^EDIATELY PEMOVE VICTIM TO •FRESH AIR. CALL A PHYSICIAN. ,,c•, t:..:s'. , y , :F�.. , :f :4;:a;: ; <Y::Fc �a y: ;s.:,. \c;tati <r,• :t s' cs;• :�C�is,:sjc=i�ts4a!t:�:='ta:sat = k rca,< ;,csi # atat SECTION -6 TOXICOLOGY (PRODUCT) .:�... ••• • • . . > . .'e:`•..•rt>;c { 't \ ::j�'• :; t: } •i,::;ta;tr:a'.;c = >.: =:ka t:•t: r <�< r. e • _' � 1%* a`•a e dc:�. F x::}: ,. !t �t a� tk # # �k; ;c * * FOB MIXTURE. HARMFUL IF SWALLOWED BASED ON CONSTITUENTS. :LIc - NC DATA FUR HIXTURE P-2008 LL_5U= NONE ESTABLISHED U22_2 N/A -r 1 ) FUJI HUNT J MATERIAL SAFETY DATA SHEET EMERGENCY NO: 1—(800)-424 -9300 EEELENI1 BALANCE iwS? _ i! �+'- %= 0. ;ia.'< ° „ii�•YtiF FUJI . HUNT PHOTOGRAPHIC CHEMICALS, INC. VEST 115 CENTURY RD. • P.O. BOX 988 'ARAMUS, N.J. 07653-0988 ATALCG NO: 522380 PAGE: 4 OF 6 IP -2008 LUIE_T:.I_':i1_1 =1i NO DATA FOR MIXTURE A.^".LLULLaJ.LL NOT KNOWN TO BE CARCINOGENIC BASED ON CONSTITUENTS. NTP :NO IARC:NO OSHA:NC INGREDIENT(S): : UI LEL•;1E , NOT KNOWN TO BE MUTAGENIC BASED ON CONSTITUENTS. YL aI11)U1 IRRITANT ; '.'11.1 FUJI HUNT MATERIAL SAFETY DATA SHEET EMERGENCY NO: 1—(800)-424 -9300 .1r1U_ILSLILIIONI IRRITANT I L!ILIEAL_�J!!I_S_DE_AILUEEIION: INH4LTION, DERMAL — ELECIS_::E_ACUIE_EIE2511E.E1 SKIN, EYE AND MUCOUS MEMBRANE IRRITATION. RESPIRATORY RACT IRRITANT IF INHALED. - EELTc • L>:iE0tA1L_Fl2O51EL1 MAY CAUSE DERMATITIS. s */., c', ,,: ,::i -4iA*:rn sac:!*14: feic*t; s:! s:! es;:*** i, 4***k:: ye:; es; s :(e*0:s!css*$s1c>;c*%ifs;t:{ * sit**lke([********* tit* SECTION -7 SPILL OR LEAKAGE PROCEDURE (CONTROL PROCEDURES) :;s>'• >. :rs .s *r:*Y,::;:?,t Ycs;•:{cae:::;saf* s; ta<: je iaskxt fss>( a>;t>( si,: s; r; t: h*******psis:itst:ts*ft:ys*cls>le ; s**>4r*:(t*if***>; *, . CILON N _ED2_LLIEEIAL_EFLEASL_Og_SEILLI OR SMALL INCIDENTAL SPILLS AND LEAKS, WEAR CHEMICAL SAFETY GOGGLES, AND ,FOPRENE GLOVES, AND APRON OR COVERALLS. FOR LARGER SPILLS REQUIRING EMERGENCY ESPONSE, NEOPRENE BOOTS AND RESPIRATORY PROTECTION MAY ALSO BE REQUIRED. FOLLOW 'SHA REGULATIONS AND NIOSH RECOMMENDATIONS FOR RESPIRATORY USE (SEE 29 CFR 910.134 AND NIOSH PUB. 87 -108) AND EMERGENCY RESPONSE (SEE 29 CFR 1910.120). SOL,ATE AREA OF SPILL GY DIKING. STOP SOURCE OF LEAK. ADD DRY ABSORBENT. CLEAN :1.) AND PLACE IN AN APPROVED D.O.T. CONTAINER AND SEAL. WASH ALL CONTAMINATED LOTHING BEFORE REUSE, AND DISCARD CONTAMINATED LEATHER SHOES. :;tic,', .s s:. «':i:' :: iss'c>'ss' - ;::Jc :.:ic:'ca':ss: <:� s� **:¢c**:rm:{:** s;:: 4s;: irafsF*sis: tscsGr: k*: ss:is ***arC********ifs+ SECTION -7A SPILL OR LEAKAGE PROCEDURE (WASTE) i *,.. ::'s t sr%Fa <*>4,1:. °,c 4*m ;:: tit :'s><c >F:!c:(rs4*>::a;t ty **s't:k.t**3!=:{c*>{c:( *s;c%'cs'Eits ** ** * * *s * * * * * * * * * ASI__L1S. ISPOSE OF CONTAMINATED PRODUCT, EMPTY CONTAINERS AND MATERIALS USED IN CLEANING P SPILLS OF LEAKS IN A MANNER APPROVED FOR THIS MATERIAL. CONSULT APPROPRIATE ED.EPAL, STATE AND LOCAL REGULATORY AGENCIES TO ASCERTAIN PROPER DISPOSAL RDCEDUR e :i: s : *,,a: :1. :'c ?•tis ;;c:•'c4 :fit *** ; :s v ,..;: •s?esc ;tc: :: asks;: :;cshscalcs.c*ski<:c: asses; ssficsjcsc**asijcssshs (ssksQts0sQcs(s** SECTION -8 SHIPPING DATA ,.z.. :•.c.,c : ;,l,s: ;s:t. ; c ;iic +�s!c Y:itt xs'si(>e ;c: ::i ;. 4stcitY,eszY. se: ;c s;::Qt: Asp. *><• : ac . sks':e*s}c *sksk*s°ssf** *4 :]I_SL_S`• :n;'ROSIVI= L1JUIu, '1.n.5. (CONTAINS ALKALI-3ASED POLYCARBOXYLIC ACID, IRON SALT)* 1I_I. IcJ'E'_I? C']RPOSIVE TO STEEL. , IJN 1763. r ::. r•r : 11 t., ••,a:, . :cs,... , :)•l .i<s:, , ' t•' + ;s: ;:i:i,i +:,t�.: ' /.s: > <st:;: >'cst s; s:. :4 a•:tC3: >':s4 *:ts s'ts i•sc2,s><tsic:hsy *>e*sks'lcsfsk FUJI' HUNT PHOTOGRAPHIC CHEMICALS, INC. NEST 115 CENTURY RD. • P.O. BOX 988 'ARAMUS, N.J. 07653 -0988 :AT.aLUG Nn: 522380 PAGE: 5 OF 6 �I�3SLSIY SIL L_i r 1:15ILBLE_ AI_ DELEEES LELSIUS. iAZA °_t_t: �1Ji_L'JLYLEEIZAIIJi1 MAY_DLLUE1 AILL_DDI_DLCUB? X ELTS:1r_?JSJIi NOT APPLICABLE ;EELS_IL_'iS3YII1= 1.193 ( kATER = 1) :LUJaiLIIY_S ^LWAI__: COMPLETE :JL &ISLES_ APPROX. 70 :A22S_CF1 DATA AVAILABLE (AIR = 1) HYSICAL DATA ;:a: SLIGHT VINEGAR ODOR nr: °_I"' = lii=L? • NO DATA AVL? r • E 1.1/3 ::_EL'ICIZI_JE_U IE L_'IL_i?SSIsSIiaial? NO DATA IRr '. :'P. EXPLr) ION H4ZArD W -2009 Eb_EALIDE_ 4.8 Ir :AIJcE1 NO DATA AVAILABLE in.i : IIL_-_a lLI .IIIYIIY_IJ_L_faiLUILAL_ICPALI : NONE — S ^ �S1 IIYIIY_ID IL NO DATA r°'� 1 FUJI HUNT MATERIAL SAFETY DATA SHEET EMERGENCY NO: 1-(800)-424-9300 SECTION REACTIVITY DATA fc teas c:e: :tq <d :;r:4:4f; f ; :f, :%I ;e ats'<:,:s~:s; ::fts esk <ft Yk s;< s;< llt s DzSEEES EAUBESBE_ :L iCiISD�s Ttl AV]ILj EXCESS HEAT :L'L'?i�PEIS:SLSIY: STRONG OXIDANTS, STRONG BASES, PHOSPHATE — CONTAINING COMPOUNDS. IAL Ja_1.:L22DSSTIDb_2SLJDU1 : OXIDES OF NITROGEN, CARBBON MONOXIDE, CARBON DIOXIDE. :: ,:s: s: .. :ss :is,: >,: 4:t: :; ,t,t:::'::�c.', «: • st :,e r :; a:»:: s 'cscs!e:!t�Fs4s' tie:! t:', estiff: sksycit: 4sl:: fs' f:+ cses} t� .:�t�fs(tsjesyCS�: * *aje * * *:{t= SECTION -10 PHYSICAL DATA •s s: , ,, t7:i:s vat r -,•:.o •; , ,:s;:)64tfe*...es!es:rs: ;;,4s'rties'cs, ),4* c; es?:: Itsytsk:;e*2 /pyr.**v ** * *y.f * # * * *s BDILii1L_2DItaiAPPROX. 212 DEG. F YAEDB_EEESSUEE? APPROX. 15 MM HG EYAEDEAIIDI!_BAIE! APPROX. 1 (WATER = 1) s:t :. Av: , re: :s,r: ip:ts;ti4 its'hs;:*42::: *i;clt*:+ t* ,: :>', t: trycy es;C**:ytatir*S!taksf*Y, * *:liitst*f;t*slC4**sf*: *x. s.;. ••;t. c, .t :_:c!_ is %:<sc f,i,: *: :! ei *s' ts;<, es;: iksK*s!::; ed Ff **e;•.: yt> (esj:Y,er(esk:h9c*** *# * *ie * * * *a SECTION -11 CANADIAN ADDENDUM ,!,,I:, , . ., :f: :':,1A c: :;:f. wi ske,. ,:=+**t: s;: af> {:ses!cs!<s;<>{t 7 4sk*Sjtskr;esh** ter** :!e*its't>f*sk*sQr***4,i. ESEELUi_EDILI_ < 32 DEG F FUJI HUNT PHOTOGRAPHIC CHEMICALS, INC. NEST 115 CENTURY RD. • P.O. BOX 988 'ARAMUS, N.J. 07653-0988 ATALOG NO: : PAGE: •'OXIC''LCC ICAL PROPF;RTIES s'ejCq::: :s:, ;td....:s'• ` ;csr?t�rs a;t:kl: isz,sc . iESSiIi1= IiJN_IO °nJ1SI_ :EE SECTIONS 43 AND .06 :_P�J'1lJLIiY_IJxiLiIYi . TONE KNUAN OR REPORTED' P -2008 r ' FUJI HUNT {• MATERIAL SAFETY DATA SHEET EMERGENCY NO: 1-(8001-424-9300 b OF :E89IJ�E_'iLiIY: ONE KNOWN OR kEPORTED '_! e L+ F. JF _IJdiLliLLS.I�:ALLY_SYL�F�Si5I1L i,CNc KNOWN, SUSPECTED OR REPORTED. 7 :;.,,:s fi x,: •s,c <a;::k ,-�. .C:je ;<sz�4 ;f•s t sr ss c c ac .�. •'�''` � .; .►. 4 .,r ..� fit; * s(c�:.',ctcs}e� sk?� ��i�.#�?'kdk��F� #�k f ik*****i441410g**3 nrnrs rnrurmairon - t:oncentrate / Fieplenisher For Process C-41 Flam- Personal Amount Parl Health mability Reactivity Protection Ingredients Yr, CAS $ Product Mixed rieplenishef• UNILEC'" Flier and Replentsher 60 Gallon 818716 220 Gallon 818726 Mixed Replenishef• UNI .EC'",' LA Flx. and RepMnbher 414 talon Conantralw 818717 O 0 C Ammonium •rhiosulrate <50 Sodium Sulfite <15 Water Balance 0 Ammonium •Ibioalfate <40 7783.18 -8 Sodium Sulfite <10 7757.83.7 Sodium Metabbulfite <10 7681.57.4 Water Balance 7732.18.5 Mtmoolum 7ldoatilEde <15 7183488 Sodium Maw <s 7757-83-7 Sodium Metabid6te <5 768147-4 Water Balance 7732.18.5 . L.. A M CZ 33 to 0 -.4 ff HMIS n as of Apr 1995 For additional safety information consult the Product MSDS sheet. To Order MSDS sheets or HMIS labels Please 001800-526-0051 En 10 • �v _ For Medical Enwrgency Call 800. 424.8300 Pages: 6 For Chemical Assistance Call 600-5264851 Hazards Warnings 7783.188 Shin, eyes mucous membrena and respiratory tract irritant. Alfa. jig: 7757 43.7 reaction to Sufism "N1' cause ntpintory distress. anima wbb bo I 7 or industrial Bence (Sodium 1 pocbiovIW can tears soak gases. c Mumxdurn11*si lfste <15 7783.268 Skit, eyes, mamas twenirause mad respiratory )rod t&FM.sw . Water #tl8ae <5 7757.83-7 Allergic reaction to Sulfites may cause aspiratory distress. Water Balance 7732.16.5 Contests aritb household or industrial Bleach (Sodiuwi llypocblorie) caw release toxic same. Sbin, eyes mucous membrane and respiratory tract irritant. All igi,: nation to Suyrta may cause rapirutory dismiss t]rntact alb bouss1ok! or industrial aleecb (Sodium /lypocbloria) can release tactic gases Afep .. cause pulmonary sanitation. Skin, ryes mucous membrane and respiratory trod irritant Allergic reaction to Sulfites may cause respiratory distress Contact with bowiebold or . indualriai ltleacb (Sodbtsss . llypocblorite) cast release toxic gases. May cause pug- treawv sewstthratiow. • FUJI HUNT PHOTOGRAPHIC CHEMICALS, INC. NEST 115 CENTURY RD. • P.O. BOX 988 'ARAMUS, N.J. 07653.0988 .AT1'.LJi; ':.13717 'AGE: 72 JI % NEWTON F'!JI T':UC(JLOP PHOTO, INC. 1332') F. FIc 3LVO. .465_1:2]j? NOT •S.IG;IED /MIXTURE 1 OF 6 SANTA FE SPRINGS CA 90670 • := AQ7_10U:_ J.IILEC LR FIXER AND REPLENISHER (UNILEC LR (TM) ) PHUTJGRAP'4IC FIXER AND REPLENISHER (TRADE TRIALED AS CT-334) REF: FH114 1E_'IL9L_E:1�ILYi :1IXTURE :EIJIL9L_E:1:.nL9_ • M I X T UR E ri2 FUJI HUNT MATERIAL SAFETY DATA SHEET EMERGENCY NO: 1— (8001- 424-9300 INFORMATIIJN PROVIDED BY: FUJI HUNT PHOTO CHEMICALS, INC. PARAMUS, N.J. 07653 -0988 TELEPHONE: 201-967-9603 DATE ISSUED: MAY 24, 1993 DATE PRINTED: MAY 19, 1995 i,,';:'.. '•• As,: ::;.i,*". :*.fc01':c raas'-i,*%s::j:acs:c : *** >:4 * ** *,:::yr*,a:!c****** *cicY:*** SECTION -1 IDENTIFICATION �. '•'' K; '- •<:c:in:, �c;:;i,.�• : ts;: 1:; �>:: Yc: rK: ��c�c: yc:':►; c: �: sc:; c•;: sc: F: r;::, t:(:>':: k�c: yC:', c: �C�ti:{ c+! c: �csh ;c�C:(:�tisl�c�cu�csksc�C *�C .L "_^TELL_= ':s:._<LEII?13 CLEAR, COLORLESS, AQUEOUS SOLUTION WITH SLIGHT AMMONIA TOR. s ! :�. :r.. • .3:,: :i ,c:. , :.es=i: 'Est. \.•e{*:;: .:e ;<:! 4+es�C >,s �s: >�s5c:k:t::�c h:+� :tie�:�C i %}:s;t�e %i=rk * ;'. •�iT�:�f t ;:Jsskie *�`•* * * = SECTION —2 NORMAL HANDLING PROCEDURE ;cs:s..,. .,.�•:4.• . ,..:�- s::a ci1..ie.4st5 t1.411 :5;C*5 :: ;:*4(4:5;45)05 43' i*.el: 4.e5 :5ki.g1C. ert:}c:ftst:!cseye*s< *4110. es *5:4,‘eita`: SEL LII:NfJ_I'' T..": I."r_dAU2LIW _Ai1L'_5I0E9aEl 0 ':')T TA'CE INTERNALLY. AVCJIO CONTACT WITH SKIN, EYES OR CLOTHING. UPON 'JNTACT WITH 'YES OR SKI.`N, WASH OFF WITH WATER. AVOID BREATHING MIST OR VAPOR. TORE i" 1 C 1L, !1 ='Y, 4ELL—VENTILLATEU PLACE. AVOID CONTACT WITH STRONG ALKALIS NO .CIC • THIS P•V_IOUCT C'JNTAINS AN AMMONIA COMPOUND. DO NOT ALLOW THIS JLUTIi7N t3 C T•iE Its CONTACT WITH HOUSEHOLD OR INDUSTRIAL BLEACHES (SODIUM YPCCHLIT ). MIXING uF THESE CHEMICALS CAN RESULT IN THE RELEASE OF HAZARDOUS '. TOXIC INHALATION ,;F THESE GASES MAY CAUSE SEVERE RESPIRATORY ^PIT,TIDN. yi5: CLI ' ICAL SAFETY GIGGLES !;U_ vE mo t' "L 'r::'I A': 1 ;2 L _ \ - JST T t-.L; ::: 1 FL:•"!r•'ILITY: — E=L, °''4 'ILITY: IP -2008 v•1TILATION RECi1M "!EI.DED TO MINIMIZE EMPLOYEE EXPOSURE ':`.:ACTIVITY: 0 PKtJT •CTII;N: C '!=ACT I V I TY : I SPECIFIC HAZARD: =UJI HUNT PHOTOGRAPHIC CHEMICALS, INC. ZEST 115 CENTURY RD. • P.O. BOX 988 'ARAMUS, N.J. 07653.0988 .T,aL:3G '41: L.10717 PAGE: 2 OF c EMERGENCY NO:. 1-(800)- 424 -9300 ' : c?: t* *itica'c :4y; *uiAi:l c>va�:�: ;:e<ic:ti•:;, **P:!t**tc *it>; ** r hs't�cN: catatr:****#*it**t� *: .SECTION -3 HAZARD INGREDIENTS . •'a. Yt �': Y .'� , .!: tt ;t :� •L :. Ki!)f at 'yt i1. `t a't )t �t�:!!t Jx �{ T; t: t';::; C: '?�.�1�<�:�•i�.7�:�� / <7ilJ�i)�i 1f �[�'�!�C�ii,:��t Y�: 7�i t�t �: 7�i fiClk lC ��t 7MiYT'f•���'1` *'T�a. 4MMONIU!a THIOSULFATE 77B3-16-6 3 jA_eEL: N.JNE ESTABLISHED SHED 23 MG /KG (ORAL-RAT) Zsi�ZEZr'`'r " ~ r = LTA: SKI`), EYE, RITATI':!N. SODIUM SULFITEE A�_ {Isi 77:7 - °3 -7 SJA_ °_EL? : 'NNE ESTABLISHED r SO: •SEE 3ELO4 LL_1Q1 NO OATA LQzIIELC I_ .EE .LIE? SKIN, EYE, MUCOUS MEMBRANE IRRITANT. ALLERGIC REACTION MAY RUSE RESPIATORY DISTRESS. MAY CAUSE RESPIRATORY IRRITANT AND PULMONARY ENSITIZf TION. LDLO 2c'25 '1G /KG (CRAL-RAEBIT) ALIL_iAIE I L_ SODIUM METABISULFITE AS_U'JJ_ 7551 -57 -', 1eA_e =L:. 5 mG /t•t3 TWA 15.1L_2ar =.ILL_ ' 15_AlL: 7732-19-5 'I:JNE ESTABLISHED :LLZEjr .YT :u CEELTS: NONE ESTABLISHED. a -2008 EEECZUL. 35-40% EELLZIII I 5-10% 2FELZ Ii 5 eEE.CE.^NI3 BALANCE LX `IC)NE ESTABLISHED T FUJI HUNT MATERIAL SAFETY DATA SHEET LL_24i NO DATA MUCOUS MEMBRANE IRRITANT. MAY CAUSE RESPIRATORY DAT1 AV",ILA;3LE LL NO DATA AVAILABLE ILLIIEILA I_EE1SI 3 SKIN, EYE AND MUCOUS MEMBRANE IRRITATION. MAY CAUSE :SPIPAT:?RY I:RPIT;,TION. ALLERGIC REACTION MAY CAUSE RESPIRATORY DISTRESS. : � •rl;::� :7:7�: : Ya:a.a:J r.;�:a :,ta;<a1y:a'li:f• );.aci ::t it r;: a` ,c r.:141, a;•:a'.•dti 4* / :tt4>''i.*** *fit +,c *'* *ac ' i CT1i:.V -4 FIRE AND EXPLOJSION HAZARD OATA tt +' r..:�; t�!Y.:i: ::i. t.ril• n• ►;:.;ta %at a ;i>?.it'� a o'c :ac !ca,t 1�iat>! �c1 a4 �t it a' r: tat 'cahac dt • ac c• • =UJI HUNT PHOTOGRAPHIC CHEMICALS, INC. VEST 115 CENTURY RD. • P.O. BOX 988 'ARAMUS, N.J. 07653.0988 ATALG `1.1: 61 717 PAGE: 3 OF 6 .LL:: .. iJT_j_I` NOT FLAMMABLE 1.2:1E.1 N/A :::E__:1La.51EILLIIE s NUT ?EGULATED (NON— IGNITABLE) 41,11Isiii:l_+_nj.11t CHOOSE EXTINGUISHINNG !MEDIA SUITABLE FOR SURROUNDING ATERTALS. .E_LILL__i'E':._Jr•Z A =- _::_EIS _ELI UIlJa_EELMEDUEE: WATER SPRAY SHOULD BE USED TO U+JL c. IP : EXPOSED CONTAINERS ANDP2R TL1 DISPERSE VAPORS. USE NIOSH /MSHA APPROVED nSITIVE JRESStJ E SELF—CONTAINED BREATHING APPARATUS WHEN ANY MATERIAL IS tIVrjLv .0 I :: . FI;<E. • , i ,: .. :,:. ::i.t.: :i:a.; *it:;.A.v. Afc:{.:;et;:ie►< !r *t.a'tats;::;<akok:;eIY**ie e** *** *fie *** *: SECT Ii.:;N -5 HEALTH HAZARD DATA y ,, ! =q .i: a *:: .ci;.e- : A t , :4ci:s'c:,e** 1,,vie: YYa, * Y, e ::,ca'c***t' <:;crtise**1. -t*A **eta.1 ** * i **0 * *** **** ** .HEELUrIL;U_L L I_yALIJE SODIUM SULFITE — 5 MG /M3 (TWA); AMMONIA — 25 PPM (TWA) 35 9 !M1 (STEL); (4CGIH 1991-19 °2). :YuET :c_'JY= z_= 1E?Sll4=_ EYE, '1UCOUS MEtiBRANE, AND RESPIRATORY IRRITATION. LLE GIC REACTION TO SULFITES MAY CAUSE 'RESPIRATORY DISTRESS. "Z EE_CI_EIESI_9IE_EZUEEDUBLS • }w!: I;•1uEDIATELY FLUSH WITH C:JLL WATER FOR 15 MINUTES. CALL A PHYSICIAN. /Pa: IMMEDIATELY FLUSH WITH WATER FOR 15 MINUTES, CALL A PHYSICIAN. IN CASE OF INGESTION; INDUCE VOMITING UPON :MEDICAL ADVICE. CALL A HYSICIA'v. NHALATInN!_ IMMEDIATELY REMOVE VICTIM TO FRESH AIR, CALL A PHYSICIAN. t: s:. .... .r:.. :s :::i. :i: :ri. ' i,. ,:i<a:a�.::t.::;:+ atatt�MC ' ts�k ►' !'e:lr�ete fea��ts4c�: # *fix *�. SECTION —b TOXICOLOGY (PRODUCT) •: ,:Y: ; r::�- �:.:k�'•i -:ia:, y:a <,ta; iesa�e ye�:c'<a'c ;t ;e:l Ors: ; °.� :+t:Kr:,:�t:7 �t ; < ;e:;e:4ot�':�:�e�:,�C ;Ys�e:M1t k * *4 *ak * *�Ik:1 E'!I__2::L_L`?_ N) DATA Fi;? •FIXTURE. HARMFUL IF SWALLOWED. S:1lI' r'!' ,'^,aL_LJ_i NO DATA FOR MIXTURE GAT FOR MIXTURE Ac• CT' h ?,T 'NNUNN TO FE CARCINOGENIC OSHA:NO ['(E J I . :T (;) : BALL - 'T T { 1W1 TO 3E ,1UTAGE.NIC I ^.c ITANT [ .- :.ITAtaT ;.'•ic[wrI1' L DERMAL CONTACT, INriALATI IN, INGESTION, EYE 1P-2008 MATERIAL SAFETY DATA SHEET EMERGENCY NO: 1—(300)-424 -9300 UEEESI N/A =UJI HUNT PHOTOGRAPHIC CHEMICALS, INC. VEST 115 CENTURY RD. • P.O. BOX 988 'ARAMUS, N.J. 07653.0988 ATALDG ^Ji: "1F717 PAGE: 4 OF 6 LFE:IS_JE__L1I___IE_SUEI EYE, MUCOUS MEMBRANE, AND RESPIRATORY IRRITATION. LLE G [C . EACT I0fi TO SULFITES MAY CAUSE RESPIRATORY DISTRESS. MAY CAUSE ULMON4,:Y SENSITIZATION.. EESLIS_•SE_LUE_'UiL_EAE::SUEE_ NONE KNOWN OR REPORTED a•- ..y:•rt ce -, , ';: e': :ti::'c4 co. e:k..? ,;f:.:,.,g,, .:e r: }ta,`•a4 }` ;. eta ;:a:a'ehatie;. ;:•sic:4>t�.aat� ac:!:>,: a; a ;ce?e:I<�e,�ed.a� :�.i,<s!aitf! afteQt:(ta� #tit #aft: SECTION -7 SPILL OR LEAKAGE PROCEDURE (CONTROL PROCEDURES) a:.. .:'rt.. ..:'-:;*. t,t*:14 , , :, :*$:4a;cajc*n't *i :ys;, * sir%,e0,* i. s*>: a; ea;:*)** ak*:; t*a4**a (::at:{s:k:{e*aje**4[**: LIi J_E11'_ jAiESIAL__LEASE_jE_SE1LL_ OR SMALL INCIUE ?JTAL SPILLS AND LEAKS, WEAR CHEMICAL SAFETY GOGGLES, AND EC.)PENE GLOVES, AND APRON OR COVERALLS. FOR LARGER SPILLS REQUIRING EMERGENCY E.SPUNSE, ;JEOP :�EI•IE SOOTS AND RESPIRATORY PROTECTION MAY ALSO BE REQUIRED. FOLLOW SHA RFGULATI :JNS AND JIDSH RECOMMENDATIONS FOR RESPIRATORY USE (SEE 29 CFR 910.134 AND NIOSH PUB. 87 -108) AND EMERGENCY RESPONSE (SEE 29 CFR 1910.120). SOLATE AREA :IF SPILL BY DIKING. STOP SOURCE OF LEAK. ADD DRY ABSORBENT. CLEAN P AND PLACE IN AN APPROVED O.O.T. CONTAINER AND SEAL. WASH ALL CONTAMINATED LOThING rEFORE REUSE, ANC DISCARD CONTAMINATED LEATHER SHOES. S ;:it: :!ca, ..... a;; 4 , :74m • * ** -P. :** :tat -jta,:tla;:*ath <h:;c** *ic t:'eat:vt*essta *,:< it*: f: 4 se #a. *a}:stal¢>it*eQt*,,stY* SECTION -7A SPILL OR LEAKAGE PROCEDURE (WASTE) : ta' +.�;ir:.:s(<a; ::e�t:;::;:r•, ;: ; ,?A 4,:e.r:4sr*:4a4erct:Y,:i< sF:t:;rzit:; tiro'- ati*. fa!:> r:; ta;< ajcXt*ic*a4*a,< a4*:;t>;.*atita4a;:yt*:,tai*,i, tt*l(t*ekt(<*;t>Mt:/ea+ra ASI _DISEUSAL_JEIED11_ ISPijSE OF CONTAMINATED PRODUCT,EMPTY CONTAINER AND MATERIALS USED IN CLEANING P SPILLS OR LEAKS I:1 A MANNER APPROVED FOR THIS MATERIAL. CONSULT APPROPRIATE EDERAL, STATE AND LOCAL REGULATORY AGENCIES TO ASCERTAIN PROPER DISPOSAL ROCEDURES. .11", • - .;a .c•‘as :,#, :: :!;i:a' ra::•; t: kicstaft* a' r:,: s: o^::, ta, ! * *, % ;ckei;:le:;eAapat.•,*3:,j **,:<*A2Ir>fir*** yak:(t**:KeQtepta(tataex<* SECTIL)N —E SHIPPING DATA Va;.a•;ca::r': , , . rt'c',; :*:'r:<., •ICY:ati*'+ "a tai•; tas�t►;:;e ak> ka':Y ta; ra t*:: ie:k *ae*>;eaea'e*7yctka,<**ac r:;t:t2t***********a 2I_CLA SL 1EOIC:.LS ';.J.I., 'JLJN— G.J.T. REGULATED :I_SIdIcJE�IL NtJT APPLICABLE a; .- a. ,;•. , , :;::::•a;ta; :a•:4 4.1e vit gezt:> it:; tt4*:; cata•: a': Pcat.- xtY; t:; tajca\: ta;: *eht <a'<*a4$c*:1*iaa;t**afak *4411031 SECTION -9 REACTIVITY DATA a ..i4: r >,::'_>.•; is - : • : :a +a : :+:ica; . {:Y:: .1:4. : a; tic: lea' edra`: a;: a; rt;:at:`a<lea;::•eat'ata;t **stat•i M :ncAO: # * * * ** ** * ** ILLILiIY x U^_SI_ ILEL ALL P -2008 DEa2EES CELii115, 4ILL_t LEI_ JCLU. X .::1LLIIlLt1_I]_AV J.L1 EXCESS HEAT ST,:nG ALKALIS, CHLORINE BLEACH _ :'FL::,w1.51I1_N_'ESLILI_ AMMUNIA, SULFUR. OXIDES, SULFUR FUJI HUNT MATERIAL SAFETY DATA SHEET EMERGENCY NO: 1—(800)-924 -9300 DEEEEES EAME E. ": :. • :a. .•3. .., :� :i,a: :a:,:tt :,t4 •t�!: .i::t: . ;:,;: a.iti::, •a't:;cit;.ata'c t:k a't'i::. :as 31,c it.4. L• t its ir.ereit Dic 4t*i< t - HYSICAL DATA FUJI HUNT PHOTOGRAPHIC CHEMICALS, INC. WEST 115 CENTURY RD. • P.O. BOX 988 PARAMUS, N.J. 07653 -0988 • :LTALJG NO: .: .-,1 PAGE: 5 OF 6 • ...:: :: ; :c...;... scat:;.:;e ;tr ::': :;::'t:'t9ea;: : *v...1;1.*s; 4ce :r4 4..it21 **1.t9•xc t0:rt* :::,e ;eaia!:zic * *4:**:;e ** ***44:1 1 .4** !ELII::D_ NOT APPLICABLE 1=DILh1i_ELINII> 212 DEG. F 1.33 — 1.34 YAL'D8_EEE5.5U E1 APPROX. 15 MM HG (,dATEr: = 1) :DLD_ILIIY_I AI =E? COMPLETE EJ_EACII]EI 8.2 — 8.3 Y9L�IIL =�_ APPROX. 50t; EYAEOEAIIDb_BAIEI APPROX. 1 (MATER =1) 1 ‘PPL I C IF LE (AIA = 1) ea!•r,, . a , t:..: a, c:.t:,. icsri! it; J•:;: *,4 s::: k;<:; cit iic: 4:, a': grata;: s4: jc: jt:,• at*Y, r:{ ta; t; tsY****:; cxt; tacaY >k ;t*i't *iF*tlt' * * * # * *** ** >ca;;ic•:• , •s ::t ; ;,• tiir,e:e:t:t a!e :ta2 * ,::;r:cr;ea,". * :)c** <* Yr .::a;:y.*3:eke:;c** * * * * ** ** * *** *70 * **2;0$* ta;:sjt ** * * * *** * * ** SECTION -11 CANADIAN ADDENDUM :ss,. , s :: ;c:c -: +c kicc::+ti: +;:•'.,� ;<>:.>;::jc>;tytf'::;c:;: * *** :** **aF=k% *);c**;4* *Yt*** * ** **0* * ** ?1122: SLIGHT IMCN I A DCL'_IU iQL:I - T , DATA E EZIL_EDIIYI_ < 32 DEG F �_LJ3IIYI NO DATA :1;F_PILI :_II_D:_ AAIEELLIL_DISI3Ia51IICNI NO DATA :IiE r.:XPLJSIUN WAL4TD • T- r1Pr? TU?P: NOT 4PPLICABLE :LELJ_I_II___ :_ SIIIYIIY_IL_yELUANICAL_IdEADII NOT APPLICABLE . ELL1:_ 1= I____ 1E_ ��lliYllY _IL�_�IAI1L_LI�LbAES:E: NOT APPLICABLE "CX•ICL(G ICAL P OP :RTI ES �ELSITI: =IIi I a `'CD:1LI_ ;EE SECTIt;NS 3, 5 AND n. 'L'":i: SUSPECTD CR cEFQi'.TED. ;;,15PLC .J? ;EPJnTED. 'HP -2008 SECTION —l0 PHYSICAL DATA ;S ,. r • x" VErak FUJI HUNT MATERIAL SAFETY DATA SHEET EMERGENCY NO: 1— (800)- 424 -9300 • FUJI HUNT PHOTOGRAPHIC CHEMICALS, INC. NEST 115 CENTURY RD. • P.O. BOX 988 ARAMUS, N.J. 07653-0988 .ATAL2G Nil: '419717 PAGE: 6 OF 6 .,.*;ONE .K-.NUAN, .SUSPF.CTED P . GR YEOO.TED.' . . • . . , . ., . .. • • ••• , . . . . . ;' % i t * 7*- 71 :41:: :•:t* kr tl t!'* ):c V ::e* lc l'AY,:*** -... ,. . .. . . ... , ... ... 1P-2008 .1111114%. ".■`n • ` • MATERIAL SAFETY DATA SHEET EMERGENCY NO: 1-(800)-424-9300 IHMIS Information - Concentrate / Replenisher For Process C -41 Flam- Personal Product Part Health inability Reactivity Protection Ingredients NEGACOLOR'"t Bleach Starter ULTRAT" NEGACOLOR Bleach Type 1 Concentrate 5 Gallon Concentrate 817700 • 1 Gallon Concentrate 822255 ULTRA NEGACOLOR Bleach Type 1I Concentrate 5 Gallon Concentrate 821945 ULTRA NEGACOLORTM Bleach Type III Concentrate 5 Gallon Concentrate 821950 Os.; .HMI 3 0 0 1 0 1 0 0 0 O 0 0 O O 0 D Ammonium Hydroxide Water C Ferric Ammonium EDTA <20 Ammonium Bromide • <30 Potassium Nitrate <5 Acetic Add <5 Water Balance C FarkAmmonlum FI7rA <10 Ammonium Bromide <10 Potassium Nitrate <5 Water Balance C Ferric Ammonium EDTA Ammonium Bromide Ferric Ammonium PDTA Ammonium Acetate Ammonium Nkrate Water C FesricAmmonh*n BOA <5 Ammonium Bromide <5 Ferric Ammnonlum PIMA <5 Ammonium Acetate <5 Ammonium Nitrate <5 Water Balance C Amount <20 Balance Ammonium Acetate <20 Aminopoiyeatboaylk Add, Iron Salt <15 Ammonium Bromide <10 Ammonium Nkrate <10 GtycoUc Add <10 Water Balance Ammonium Acetate <10 Aminopolycarboxylic- Add, Iron Salt <10 Ammonium Bromide <5 Ammonium Nitrate <5 Glycolk Add <5 Water Balance CAS # Hazards Warnings 1336.21 6 Corrosive to eyes. Skin, mucous membrane and respiratory tact inita,u. 7732.18.5 21265.509 12124.97 -9 7757-79-1 64.19.7 7732.18.5 21265.509 12124.97 -9 7757-79-1 7732-18-5 <12 21265-50-9 <10 12124-97-9 <8 111687 -364 <8 631.61.8 <5 6484-52-2 Balance 7732-18-5 21265.509 12124-97-9 111687 -366 631-61-8 648452-2 7732.18.5 63141-8 111687.364 12124.97.9 6484 -52 -2 79.14.1 7732-18.5 ation as of April 1995 For additional saloy Information consult the Product MSDS sheet. To Order MSDS sheets or HMIS labels Please call 800-526-0851 Ext. 10 For Medical Emergency Call 800. 424-9300 Page: 2 For Chemical Assistance Call 800- 526-0851 Skin, eye, mucous membrane and respiratory tract irritant. May cause drrmatitir. Contact rtdtb household or industrial Mach (Sodium Iljpoctlorite) can release Work dares. Skim, eyes, mucous membrane sad respiratory tract irritant. May cause dermatitis. Contact with household or in trot Reach (Sodium Ilypocblorlte) can micas. toxic gas Skin, eyes and mucous membrane iniant. May cause respiratory Initati m. Psofo, d or riposted contact may cause dermatitis. Contact with bowel, ales or Indus/no/Bleach (Sodium 14pocblorite) can release sane gases. hsgesiat nay anus Mdbemogobinenda especially M children. Gbrrasaue a steel. Skim, eyes and mucous membrane irritant. May cause respir spry /nitatbra Prolonged or repeated caseact way cause Dermatitis. Couact with household or /adrsotal Meath (Sodluw tlypochbrite) can refuse toxic gases. lasestdoa *say camas MethemoSobionnia especially he children Skin, eyes and mucous membane Irritant. May cause Dermatitis. Contact with household or Industrial Breech (Sodium Hjpocblerite) can lir* gases. May cause burns. 631418 111687-364 Skin, eyes sad mucous membrane Irritant. May cause 12124-97-9 Dermatitis. Contact wUb household or tedustrlal Ble.rtb 6484-52-2 (Sodbtm Ilypocbloree) cars release toxic gases. 79.14.1 7732.18.5 HP -2006 FUJI HUNT PHOTOGRAPHIC CHEMICALS, INC. NEST 115 CENTURY RD. • P.O. BOX 988 PARAMUS, N.J. 07653.0988 :ATALJG Jr;•: .321953 PAGE: 1 OF 6 7')) '. ATT J: JI.i NEwT+JN FIJI T2UC:;L PHOTO, INC. 133217 Li. FIRESTONE BLVD. S :.TA FE SPRINGS CA 90670 CHF'•iIC:,L SAFETY GOGGLES :LLYc:L_ '!;nP :ENE: GLOVES MATERIAL SAFETY DATA SHEET EMERGENCY NU: 1—(800)- 424 -9300 INFORMATION PROVIDED BY: FUJI HUNT PHOTO CHEMICALS, INC. PARAMUS, N.J. 07653 -0988 TELEPHONE: 201-967 -9603 DATE ISSUED: JULY 19, 1994 DATE PRINTED: MAY 19, 1995 •a' :l: .e:•.. ;t r, , .. ...;c_:a':::i.:a < +' crcaaa':,;tY,c:;e �:,:ipi :;c: <rr�c e; c:i�eici,::':ata,::';>tses' %:;< nt�c� <yei;c �:n;:�e:t�: ;t a! yF ;:�ea;e:fa;t,c:j �ksir SECTION -1 IDENTIFICATION .s :a::ts: :a: :�:• :s, : c c :* * ticaet•:l: ; *,:t:;ea4*ae:,ti>t **J.caj 0....4ae:j:a!* e*r<s><t *t/:tt**>teaf*4 :'SJL_AJL_ NEGACJLOR LEACH TYPE III CONCENTRATE ; PHOTOGRAPHIC 2LEACH FIX CONCENTRATE (TRADE TRIALED AS CT- 325 -1) REF: FH15b :bF_iI L_FbLl1LY_ ;i I XTURE :LJIC. L = !"IXTUf E AiF'a1LAL_nEsl IEII_�t_i: CLEAR, rJRANGE—YELLOW, AQUEOUS SOLUTION WITH SLIGHT ACETIC \CID ODOR :AS_J)8.: NOT ASSIGNED /MIXTURE SECTION —2 NCRMAL HANDLING PROCEDURE -ta't: r :cy :, a• +;:; <� :'' );' - ;e1t.:a;::'ea' :;e $.i:s;c:'td:,'e a!s.; <a't�ttka'talt >'e ' ie ata :k�,t a} ae .ti 't><. esQs a�siakat �. 'EELLUII:` L_I: _ =_ TAK t:L_1a_bA_ `Vi ID C^MT:.CT EYES, SKIA OR CLOTHING. JO NOT TAKE INTERNALLY. UPON JINT;CT 41THH SaKIN OR EYES, WASH OFF WITH WATER. AVOID BREATHING MIST OR VAPOR. JORF. I'1 A COOL, DRY, WELL PLACE. AVOID CONTACT WITH STRONG •LKALIE:i. THIS r'?(7CUCT CONTAINS AN AMMONIA COMPOUND. DO NOT ALLOT THIS :QLUTI 'M T. Cfl E I CONTACT WITH HOUSEHOLD CR INDUSTRIAL BLEACHES (SODIUM iYPOC.IL ;PITS). MIXING OF THESF CHEMICALS CAW RESULT IN THE RELEASE OF HAZARDOUS !R .TtiYIC GASS. INiHALATION OF THESE GASES MAY CAUSE SEVEPE RESPIRATORY r;h:ITATIflN. .IbE' : :4_ . E'!� Ail- JN UJC:\L i:.(H, \►!ST VENTILATIUN RECJNr' LADED TO MINIMIZE EMPLOYEE EXPOSURE •.0 +I ::T 1 J V t) \r'S. JIS 1 FLA' "' "A':ILITY: 0 r,EACTIVITY: U PROTECTION: C Fw_ - W'LT: 1 FL.` AlILITY: 0 KE4CT IVITY: 0 SPECIFIC HAZARD: �dttii'N*luVdnwun :UJI HUNT PHOTOGRAPHIC CHEMICALS, INC. VEST 115 CENTURY RD. • P.O. BOX 988 'ARAMUS, N.J. 07653 -0988 ATAL:7G NC: 621` PAGE: 2 OF 6 EMERGENCY NO: 1- (800)- 424 -9300 :t: :fir, :ita':=t:'ct�:, '• , :a;.a'ha�:e .isai jc:,:acac:i;`t�. Sri,::; s�::; tx - std ,:it:t >,sfy:Yt� :Y�:?e�ca�e%�Ct ij1F+�r SECTION -3 HAZARD INGREDIENTS :<: :,. .�: �. . : ;' d :. ''i::;e.f 3:.:'c ; •::!,i:a'e.;si:i :f :' �::; �' r �= �' t � ' a :k:f =F p: s tes:ae.Jlst:>rf>eo1< *ftak:leaks i �:: i a;.ici, a :;t a;::4:4 r ;.; a t � a •,e u 9 jL_= 'iT "�I1Li A NONIUm ACETATE AS_• ).1 531 -S1-6 ILA_2 L_ IONE EST;:ELI SHED 11 _Li2i NO D A T,; LS:_IQi NO DATA jr iPILLf_L .Si SKIN, EYE, r1UCOUS MEMPANE AND RESPIRATORY IRRITATION. SEPA kEPJ TI: +G RE4UIkE;1ENTS: SUBJECT TO NOTIFICATION AND REPORTING REQUIREMENTS F SARA TITLE III SEC. 304 (40 CFR 302 - CERCLA HAZ. SUBS. LIST, RQ = 5,000 3S.), SEC. 311 AND SEC. 312. ASIL_JSIE�L L_ V1MONIUM BROMIDE Aj_ 1L: 12124 -97 -9 5y1_2_L: NONE ESTA5LISHED :iud__:L_ 'i'ItiE E'iTAT.'LI SHED L_5Q NO DATA LL_5121 NO DATA 1:PFPLI5: IRRITANT TO SKIM, EYES AND MUCOUS MEMBRANES. MAY CAUSE ERlATITIS. , \MIN N LYCA<BCXYLIC ACID, IRON SALT 35_..+:1si EE.LEJIL 10-15% LUA_!=EL. NIN E EST,3LISHED L;,�• �;,� DaT=, LL_Di NO DATA Lis1E1rv.iiI_ =f Iii SKIN, EYE AND uUCCUS ,MEMBRANE IRRITATION. AMMONIUM NITR/TE J. I) ', 4,s4 — '12 - 2 _+n_ > G / <C (')r:;,L - mAT) // nf LE NO DATA LL:APIrLI ��1-r �i i NONE KN'l,4N. 3.i11: GLYCriL IC :,CIO P -2008 r:f: `'' FUJI HUNT MATERIAL SAFETY DATA SHEET EEELEUI_ 15 -20Y EEELLIL 5 -10,: E ELZNI1 5 ;r►' =. ,,ANC, TI ��, E' ;UI "���rtE.cTs: SUBJECT TO NOOTIFICATIOJN AND REPORTING REQUIREMMENTS -.4 T ITL!: III SEC. 313, SEC. 311 AND SEC. 312. tP -2008 FUJI HUNT PHOTOGRAPHIC CHEMICALS, INC. -VEST 115 CENTURY RD. • P.O. BOX 988 'ARAMUS, N.J. 07653 -0988 .— TAL•JG N.;: 021953 PAGE: 3 GF 6 EE1Mal 5-10% :LASli_e= `'IJI__ 1 NOT FLAMMABLE :1-V2 LE_EIEL_ ,aIYL_LI'1IT5_ - LLEs:E_ N/A UEELS _ N/A •SUs_LLS55IEILAII::L'1 NOT REGULATED FUJI HUNT MATERIAL SAFETY DATA SHEET EMERGENCY NJ: 1— (300)-4249300 79-14-1 ` ,,NE EST 0L I SHEf? 1950 MG /KG (ORAL —RAT) 1.L_1 NO DATA :IGJIcIL::JI_EEEELI:_ SKIN, EYE AND MUCOUS MEMBRANE IRRITANT. .951_i'IE =ILL_ WATER 1•' : 7732 EEE'LEJI' BALANCE 'ZONE ESTABLISHED • �_E;�s ::`.)NE ESTA6L I StIED 1..L—Q1 NONE ESTABLISHED ,•I:iUI =IL: I_EEF::LI._ 'DONE ESTABLISHED. :i:, ; i., •r- .. , :+•.. . ?. :ci•�c: 'e ;+:,• ?..+� ,: a!::. .;•se:,eieic,F:Ies aye:' t 4i,: :;ci,:ac*:;::',: t:!sxca':$a:vtr ::}eaieycs ;rat:: SECTION —4 FIRE AND EXPLOSION HAZARD DATA ::r. ,:f r•- . er:.:i , :'c r:�:,ea'c�'r �or,:f: :;c r, !c >c �� c3trr:::,ty:�c: �:a'ca:a':�;ri, i/dsscr4>:>'c.',: ir: %Y�y ae;; ' kfe:Fa;e{' 'f i::; x ajc>�t:f:; <afff:F .III LNI:UI;■;L_ILI__ CHOOSE EXTINGUISHING MEDIA SUITABLE FOk SURROUNDING !ATE4.I ALB. : EELI! L_E IEZ_ dL LAEL _L_FISE_EIUUIIYSz_e_ULELJ3s_ nATER SPRAY SHOULD BE USED TO :00L FIRE EXPOSED .CQNTAINERS AND /OR TO DISPERSE VAPORS. IJSE NIOSH /MSHA APPROVED rSITIVF ' ESSUkE SELF—C1I.TAINED BREATHING APPARATUS WHEN ANY MATERIAL I5 NVI,LVED IN 4 FI'E. +.:a. Via;: •:!:•,;, a? �co; r�;:' ca;: isi: it�ri sc. Ya<:; c >, cscaii ::c:;t'c:,aw.ic:fs:= :x %jc►c: fat:( e�c.< Yr >;:�cy.:c:'tna}c1,ta�ca SECTION -5 HEALTH HAZARD DATA t... ..: ;c•.:;.i is ?: .r,�:'.o':.;< ^:, 4:ea;c:•o'• !:c�:tc:,:,s: i.aic :!:•f:ca':+s.crs:;:ta; �r +;s:•e ?rc+!c :takac:;r:, tie: t: (c:;caisy:ata;;*:fi<ac:'f+{c. A,1MUNIA — 25 PPM TWA, 35 PPM STEL (ACGIH 1991-92). r SKIN, EYE, MUCOUS MEsB;2ANE AND RESPIRATORY 94Y CAUSE DERMATITIS. PPLLFULIEES IMM!::)IhT =LY FLUSH WITH C;)UL WATER FOR 15 MINUTES, CALL A PHYSICIAN. I •i.IJIAT._LY FLUSH WITH COOL WATER FOR 15 MINUTES, CALL A PHYSICIAN. uL_LIiL 1 C S t�F INGESTI')N; INDUCE. VOMITING UPON MEDICAL ADVICE. CALL A :iYSIC1A'I. VICTI" TO FRESH AIR. CALL A PHIYSICIAN. :ir +,.:� :�; : +c.`::;::'c ?•a: •;t:!t1 �. Stec :� :;:a: ;c.;ty yc:'.: c: s: trr: rar: f� ac���CX• 7.: 1t$:;: isir ;•:4rysY,ca:;tss�cdf�tf,s;4 >,rt: SECTION-6 TOX I COLD Y (P "IJDDUCT ) =WI .HUNT PHOTOGRAPHIC CHEMICALS, INC. VEST 115 CENTURY RD. • P.O. BOX 988 'ARAMUS, N.J. 07653.0988 ATALOG .fl: ;21953 PAGE: 4 OF 6 �-= 7 1 FUJI HUNT MATERIAL SAFETY DATA SHEET EMERGENCY NO: 1— (9001- 424 -9300 :4.•, , c : , .. .. acic:c>tz i:z;:a•.rapa: X.f:t*:!:ae ; etc >,.: ::.* -4.a'eotiu;<et:;:ie $iAietr ;*ar>;ta;ne* 1: f** pcttiae* ;c.r;.4::y:>4>dtatse*g4tje>dt) L1IL_LE�L_LL_E�_ '1/0 FOG MIXTURE. HARMFUL IF INGESTED BASED ON CONSTITUENTS. Ln 1o: NO DATA FOR MIXTURE. LUIE_1"'UAL_LL_U: NO DATA FOR MIXTURE. ALIL(;rJ1:1 NOT KNOWN TO BE CARCINOGENIC. ,VTP:NJ IAKC :tl0 OSHA:NtO INGREDIE`iT(S): 'ALL .SUIGL:11L_ N!7 DATA. YE_1:�E1I3II LL I RR IT ANT . .1J_1'?EiILIiJ i . L I R R I T A N T . .SINLI23L_20UIES_JE__2LOEEIOb_ DERMAL, INHALATION. .EEELIS_OE FIP2511EE1 SKIN, EYE AND MUCOUS MEMBRANE IRRITATION. :EE _IS_LE_LJELINIL_EAEILUE'Es MAY CAUSE DERMATITIS. i ::{c:,•:;: > a� ::t:, :ca, ;c e>t: ?ea'tit*;,;ca!: et:ta;tic:Yaf:tl.:;::t F ri * * #*** •444 *i *** e it* ik*' Y* af** a; i***>;t%f*:}t*ah**r SECTION -7 SPILL OR LEAKAGE PROCEDURE (CONTROL PROCEDURES) , !.: a,e a;:iei :ry:a::•:c:.:t: *3 1:*a;eXe*a;.sh:4af *ai * ***** *Leo;t>f:ajt:Jf:!e**zi.:k * **ric* * * * * ** * *tt * * *af** #fit * * *M0 . LI1�_ � _E�E_L�IrE1�L_?ELEASE_.8_SE1LL? PR SMALL INCIDENTAL SPILLS AND LEAKS, WEAR CHEMICAL SAFETY GOGGLES, AND ,EOPRENE GLOVES, AND APRON OR COVERALLS. FOR LARGER SPILLS REQUIRING EMERGENCY ESP NEOPkENE HOOTS AND RESPIRATORY PROTECTION MAY ALSO BE REQUIRED. FOLLOW SHA ti?EGULATIONS AND NIOSH RECOMMENDATIONS FOR RESPIRATORY USE (SEE 29 CFR 910.134 U:D ' :I JSH PUB. 37 -108) AND EMERGENCY RESPONSE (SEE 29 CFR 1910.120). SOLATE A EA rIF SPILL BY DIKING. STCP SOURCE CF LEAK. ADO DRY ABSORBENT. CLEAN P AND PLACE IN Ac+ APPROVED D.O.T. CUNTAINER AND SEAL. WASH ALL CONTAMINATED LOTHI'IG t.EFURE RFtJSE, AND DISCARD CONTAMINATED LEATHER SHOES. :.t:, !-':... :a' **ir I.,: : 1*"* iter* a' t: 4:',t:;t>;e.4e'As:a}taj *:'**>itte*M1;tt;ea4:'t:! * i.c itar :{cyt*:k*Y,eat:ft:k**:41 ltd SECTION -7A SPILL OR LEAKAGE PROCEDURE (WASTE) a. : ;c ,: : :J :a''4• : f a'<ataL:,::::;t*at:; ere: ka; c: ti:,< tYaks; ca' tYt:!< *:' rof e:{ c> tie4: al: Yeier• icaf **a;t>f:*:ieak>ltakayeak*•t; 1 •_LIS:451AL_LIEI! . ISPfJSF 1F CONFAIt'..TED P' :ODUCT, EMPTY CONTAINERS AND MATERIALS USED IN CLEANING P SPILLS 7 LEAKS INJ A MANNER APPROVED FOR THIS MATERIAL. CONSULT APPROPRIATE EDERAL, :'TAT= ;,tlt► L"CrL P'EGULATORY AGENCIES T7 ASCERTAIN PROPER DISPOSAL 'OCEL ._ S. .. ;;. :e:.rr , +:, , *,.,., :;t::c.*ept : a! *a':a't: '. ert* ac:' toka! e: Fa; e: k>' ca;!>; :a;ea;eafa;.>r* *** *>ti>;ta; SECTION-5 SHIPPING DATA 1P -2008 FUJI. HUNT PHOTOGRAPHIC CHEMICALS, INC. NEST 115 CENTURY RD. • P.O. BOX 988 'ARAMUS, N.J. 07653 -0988 :ATALOG NO: 821953 PAGE: 5 OF 6 •: r:jt:t:k ; :is :,iY m.e,;ic: 4*— .:ta4*•ha;1,ta'ti rJC*:4**:;:srsta': * cs1c*** * t sk * a * a i / stet SECTION -9 REACTIVITY DATA :srx:'t*=: , :tr,:>c :�::.e:, ie- ;c s'tY: e: ci: s, �at s ...*?!*s;t a't :;cs•. ztsitie•,e * ;e**a}e:' v24**,;:sksk:}:a;!* ors; taH**s; t:;t***sc:,:srs;ey* *slfsdts 3;e****age - 171 : 13 ] FUJI HUNT :ORROSIVF LI.JIDS, N.O.S. (CONTAINS AMINOPULYCARBOXYLIC ACID, IRON SALT; AND # 211I_5ILIJEIJI: CORROSIVE TO STEEL. AMMONIUM 6RUM I OE) , UN1760. MATERIAL SAFETY DATA SHEET EMERGENCY NO: 1—(800)- 424 -9300 iI9iiLIU1 SIAL::3 X 1115IAELEI AI? I51S • DEaLE5 EABEELUE IALLSCLUS_EDLIJESIZ.IIDyL yAy_L'LCU21 AILL_NDI_DCCUS_ X ;?yaIIIL:1S_I0_9YDIii EXCESS H E A T ::1L]JL'AI1 iLIIy: STRONG ALKALIES (RELEASE AMMONIA VAPORS), OXIDIZERS AND 'HOSPHATE _'ALLLQ 1S_ELULTJEDSIIIDr_EEDDUCI_ AMMONIA, NITROUS OXIDE • +.* ;i **0: :, *• :iii: ,:. ,: s,:a4sn:;tr!::k >'r>k **rci,: t: y `• skat**ytsts:'tafsticska;t}c` # rl`• s; t** sacstiit * * ***r'f *sK:h*** *iF * * *# c # #** * # # **** • SECTION -10 PHYSICAL DATA sx'`.# ' a! :;c ;f•;e:,e:/fi,::}ts;cr, ::;t** :r,<>;::tsel,:a'f* B iei ,:ska(:s w!* ar : # **#***:Qt:( <*s'lrapsp * rs}e #ti" ** ** * * * * * ** ,c *2 ;.**a, :a! 9ELI L_EQIZII NOT APPLICABLE :EECIEIL_aEAY1ILI 1.21 (WATER = 1) ICLUaiLIIX_iy_E9IEE? COMPLETE IDLLIILE .. APPROX. 50/ :9EDs_DEIIy_NO DATA AVAILABLE (AIP = 1) HYSICAL DATA .nDL': SLIGHT 4CETIC ACID ODOR. AljE_IE'::.k...1 '40T APPLICABLE E"J5IIY: 1.21 G /CC : JEEEILII_'I_JE_ AIE_°LLIL_DI IEldUIIDy? IRE IIR c :(aLOS Ir]'I HALAFD NP -2008 BOILII;ID_EDIyI_> 100 DEG. C. Y9E0_2aESS12,E3 APPROX. 15 MM HG EB_EACIDE_ 4.87 a 25 DEG C EYAEQiAIIL'b_BAIEI APPROX. 1 (WATER =1) :a'act; r:•.::.a'•i:o' <s':. :;c:c,':i• ;.w:c;-:c:•a;i a le . s;t* :l *t. i r #* :, 3' , : iF F E, r'a �c ac: e � e sjc is a4 �c >�c s� :(: sic •h s4 iF >i <�t arc r�::+f s( s i s;t et s jc >t ►' •�jt a'G s,'t t a;t a * ** : it sK •r.:11, i::,:a•cs;! ,: zr::;cr;res' : l:^; cs'. :;:s; ;<a!:i ir:' ** * s4* :a;t sk * s 1** * * * t s SECTION -11 CANADIAN ADDENDUM s !:i ::.ic±.,:s;:i s; ks,c:c� tits( e>'s(ea:rs'tsitit>S :ayta;::;t,ti :*rts',ties'r***r,: sjts( is ;cakZc:}ea ties (t****:(t****stta • E'?EFZIND_P::ILII < 0 DEG. C NO DATA AVAILABLE JXIC)LL1fC L.PyUPERTIES :•'Et{:I_1l3IIEL� T.fl oc:t7L�LI_. •EE• SECTIONS- , UJU HUNT PHOTOGRAPHIC CHEMICALS, INC. /EST 115 CENTURY RD. • P.O. BOX 988 ARAMUS, N.J. . 07653 -0988 !JAL JG 4 ! . '621953 PAGE: F E_!1El�LIIYF_I�L�i�:ilY_ OT ' KNCW4 OR REPORTED P -2000 6 OF E ;3 .121 :LJILIIX GT K,IO'w'1 OP P.EPORTED n:1E_2F_IQIILDLaICAL.LY_ .XLEELLUIL_EBODUCII ONE KNOWI UT?_.111'1Ii?t;_I L2EEA JEE1 NO DATA AVAILABLE 42L2LIE: __i� I. 1_:-: 5EL15IIiIIIY _ID_LtFLJAUILAL_IdEALII. APL 21.L. -2LII_ .5:. SIIIYIIY_ILI- LIAIIL_u15Gb6ELE1 NO DATA ,_ FUJI HUNT • MATERIAL SAFETY DATA SHEET EMERGENCY NO: 1-(800)- 424 - 9300 HMIS Information - Concentrate / Replenisher For Process C-41 Plant- Personal Part Health mability Reactivity Protedion Ingredients Product NEGACOLORTM Developer Starter 1 Gallon Concentrate 816463 NEGACOLOR Developer Replenisher 2 X 10 Liters 816492 2 X 12.5 Gallons 816493 50 Gallons Part A 816494 2 X 50 Gallon Part BIC 816495 NEGACOLORTM IR Developer Replenisher 2 X 10 Liters 818875 2 X 12.5 Gallons 818876 50 Gallons Part A 818877 1.2 X50 Gallon Part BI0 818878 200 Gallon Part B 818885 200 Gallon Part C 818886 M:xed Replenisher FUJI HUNT � • PHOTOGRAPHIC CHEMICAL, INC. 2 0 A 3 0 B 2 0 C 3 0 A 3 0 C 3 0 0 0 1 0 0 0 C 0 0 0 TECHNICAL DATA C Sodium Bromide <5 Potassium Hydroxide <5 Phoephonk•Type Chelate <5 Nitrilotrtactxk Acid <1 Water Balance C C C Potassium Carbonate Ambropdyearbcayhc Add Sodium Metabiaulfite Water Hydroxylamine Sulfate <15 Phosplank Add Dalvedve <5 Phwphwdc Add Dalvadve, Potassium Salt Water C Puniharilocd end a DaMelve Color Devdo5tn1 Ape Sodium Sulfite Water C Pus thmylacdandte Daly ila Cover Developing Nor Sodium Sulfite Water Amount CAS 1 <35 <5 <5 Balance <10 Balance <30 <5 Balance Potassium Carbonate <35 MiwpoKxba/Mc Add. foam bk <5 Sodium Metabisulfite <5 Potassium Hydroxide <5 Water Balance C Ilydroxylamine Sulfate <15 Phospbonk Add Daivadve <S Phosphoadc Add Datvadve, Potailum Sall Water <10 Balance <30 <5 Balance 7647.15.6 1310-583 Proprietary 139-13-9 7732 -165 5840&7 67-434 7631.90.5 7732-18-5 10039-544 2809-21-4 67953.76$ 7732.165 25646-71.3 7681-57-4 7732.165 58408-7 14001-2 7691 -57.4 1310.583 7732.165 10039.54.0 2809.21.4 67953.764 7732-18-5 25646-71-3 7681-57-4 7732-18-5 Hazards Warnings Shin, ye, mucous membrane and respiratory irritation. May .:acts Dermatitis. Contains Nitri/wriacetic Acid which causes kidney trmars i Laboratory Corrosive to shin and yes. Irritant to mucous membrane. Ingestion ma rend M naves., vomiting and diarrhea. Allergic reaction to cm caure.espirasoy irritation. Severe skin, ayes mucous membrane and respiratory tract irritant. Rapes contact may cause allergic skin reaction and/or Anemia, which may A to effects on spbwr, liver kidney. Hydroayla Sulfate may be m Wail.nlc Hydroxy:amine sulfate crystals (dried liquid spills) can explode at 265 'F. Corrosive to oyes. Seven skin, mucous membrane and respiratory trac irritant. Repeated contact may cause allergic skin reaction. AGergit reaction so Suites can caw* respiratory distress. Potassium Carbonate <5 584-08 Water Balance 77322..18 - Skin, eye Skin, and mucous teaensbrane and respiratory India*. Corrosive to all tissue contacted. Mucous membrane and tract irritant. Allergic reaction to Sulfites can cause respiratory d Severe skin, eye, mucous membrane and respiratory tract irritant. Rapaaued correct may cause allergic skin reaction and/or Anemia, whist) may lead to effects on spleen, liver kidney. Hydra:yin Sulfate may be auras Rile, Hydroxylamine swift, crystals (dried liquid spills) can aapiode at 26SV. Corrosive to eyes, Severe skin, mucous membrane and respiratory Traci irritant. Repeated contact may cause allergic skin reaction. Allergic reaction so Sulfites can caw. respiratory distress. 0 0 . C Potassium Carbonate <5 584.08.7 Water Balance 7732.18.5 Skis, eyes 6 mucous membrane and respiirtatory irritant: -1MIS Information as of April 1995 For additional safety information consult the Product MSDS sheet. To Order MSDS sheets or HMIS labels Please call 800.526.0851 Ext. 10 • For Medical Emergency Call 800 -424 -9300 Page: 1 For Chemical Assistance Call 800.526 -0851 aAL FUJI HUNT PHOTOGRAPHIC LAEMICALS, INC. VEST 115 CENTURY RD. • P.O. BOX 988 'ARAMUS, N.J. 07653-0988 .ATALJG `AL: 311-3877 PAGE: 1 OF 6 70040720 - ATTN: JIH NEWTON FUJI TRUCOLOR PHOTO, INC. 11:320 E. FUZESTONE BLVD. SANTA FE SPRINGS CA 90670 SECTION-1 IDENTIFICATION •, t 1 QAl2E_NAJ: NEGACOLOR LR DEVELOPER/REPLENISHER, PART A i4Cm1P.L. NAMT:.: PHOTOGRAPHIC JEVELOPER/REPLENISHER MATERIAL SAFETY DATA SHEET EMERGENCY NO: 1-(800)-424-9300 INFORMATION PROVIDED ay: FUJI HUNT PHOTO CHEMICALS, INC. PARAMUS, N.J. 07653-0988 TELEPHONE: 201-967-9603 DATE ISSUED: AUGUST 12, 1992 DATE PRINTED: MAY 19, 1995 (TRADE TRIALED AS CT-312-1) REF: FH051 MOD JaLULL_ELJILX1 MIXTURE dajiLaL_P„rmilIA: MIXTURE 9.5.10...1 NOT ASSIGNED/MIXTURE C-IEHICAL NFSISTANT GOGGLES (FACE SHEILU IF 10 GALLONS) '-2008 FUJI HUNT aki.1 . 4E1J 0 KErri APON :CHANICAL EXHAUST VENTILATION RECOMMENDED TO MINIMIZE EMPLOYEE EXPOSURE. - FLAMHA'ILITY: 0 REACTIVITY: u PROTECTION: C .D4 - HEALTH: 3 FLAOHABILITY: 0 REACTIVITY: 0 SPECIFIC HAZARD: COk JEMLL-2ESCZI2IILW. CLEAR, COLORLESS, AQUEOUS SOLUTION WITH LITTLE OR NO ODOR. JLOR NEGATIVE DEVELOPER CONCENTRATE. ' SECTION -2 NORMAL HANDLING PROCEDURE ARFUL IF SWALLjwr:D. AVOID CONTACT WITH SKIN, EYES OR CLOTHING. UPON CONTACT ITH SKIN OR EYES, WASH OFF 4ITH WATER. AVOID BREATHING MIST OR VAPOR. STORE A COL, DPY, WELL-VENTILATED PLACE. AVOID CONTACT WITH STRONG ACIDS. -4 v. 41 :4 1 AM 711 ** 2 "I'AVI****A.:*M***th***I*41** , ! , *** 1 4 1 ,410#****** SLCFIIJN -3 HAZARD INGREDIENTS FUJI HUNT PHOTOGRAPHIC -- CHEMICALS, INC. NEST 115 CENTURY RD. • P.O. BOX 988 'ARAMUS, N.J. 07653 -0988 .ATALUG NC): 318877 PAGE: 2 OF 6 :*** * * :;:i(4 Y. c *s:* *4:. **,.yMs}r*a'ci;.:;catsc** ;: ;e ' :** , ** ':: f: y4sese**:}c * # * * * * **: 1111:__+EI .MALI POTASSIUM CARBONATE 584- 05 -7 5111_EiLi NONE ESTABLISHED ,n_Sr�s 1370 MG /KG (ORAL-RAT) :iSidiEiLi SEVERE SKIN, I Sir,_MaI E.L Li SODIUM METAB I SULF I TE ,95_t111,1 7681-57 -4 :5E9_2ELI 5 MG/M3 TWA :95IL_tAIL2291.3 AMINUPOLYCAR©OXYLIC ACID, SODIUM SALT .z.; ; FUJI HUNT MATERIAL SAFETY DATA SHEET EMERGENCY NO 1- (800)- 424 -9300 Er3LELIi 30-35% LL-5D1 NO DATA EYE AND MUCOUS MEMBRANE IRRITANT. E_ELEJI? 1 -5 .Q_ L NO DATA LL-52: NO DATA :iLJIEIL©L+I_ EEFLIS: SKIN, EYE, MUCOUS MEMBRANE AND RESPIRATORY IRRITANT. , LLERGIC REACTION MAY CAUSE RESPIRATORY DISTRESS. 1 .A5_11,1 140-01-2 EESLEJI_ 1 , 5E9_Eai NONE ESTABLISHED p_5.0. 'fSEE BELOW LL_ .Q_ NONE ESTABLISHED 4 jL IEILA_ai_EEEELI5: SKIN, EYE AND MUCOUS MEMBRANE IRRITATION. n LD50: 4,140 AG /ECG (JUL, MOUSE) PA REPO TING EEQUIREMENTS: NONE A C_i "rIEEI1L? POTASSIUM HYDROXIDE 1310-5x1-3 EESLESIL 1 St19_1!ELi 2 '1u/43 CEILING 1_FEi 31)5 '•1G /KG (Oi(AL-'AT) LL_5Qi NO DATA I IEI i:1I__EEELISi CORROSIVE TO ALL TISSUES CONTACTED. 95ij_ 9I; ='i�Li •,ATE R :i_joA: 7732-15-9 ELiC JIi 55 -60 %: 1.111_2L"L_ ►UI•IE I STABL I SHED 7 : 3 T A L I SNE: D LL_i21 NONE ESTABLISHED FUJI HUNT PHOTOGRAPHIC VEST 115 CENTURY RD. • P.O. BOX 988 'ARAMUS, N.J. 07653-0988 .ATALOG 813877 PAGE: LIEMICALS, INC. 3 OF 6 (. MATERIAL SAFETY DATA SHEET EMERGENCY NO: 1—(800)-424-9300 L IL%liaif,A2II_LEF=1I5: NONE ESTABLISHED. --L%. SECTION — FIRE AND EXPLOSION HAZARD DATA :%... LL5a-ELita-.11 NOT FLAmmABLE - LadEfal N/A ImPEE: N/A 5 ,.. u _r j . L a.IIELL E alc il l i NOT REGULATED 111MOk FUJI HUNT III:Ic CHOOSE EXTINGUISHING MEDIA SUITABLE FOR SURROUNDING ATERIALS. .ELLIAL-E.VZ-JILLEILL-EISZ-EIliMZ-ESQLEDUEEI WATER SPRAY SHOULD BE USED TO OOL FPE EXPOSED CONTAINERS AND/OR TO DISPERSE VAPORS. USE NIOSH/MSHA APPROVED USITIVF PRESSURE SELF—CONTAINED BREATHING APPARATUS WHEN ANY MATERIAL IS NVOLVE0 IN A FIRE. • :: , := , 144?te.:r: , 0****11!cfx*A , **** , .*********4 , .*************************A, SECTION-5 HEALTH HAZARD DATA. dEPaU2L2-LILIII-YLLUE : NONE ESTABLISHED FOR MIXTURE OR INDIVIDUAL INGREDIENTS nIELIIS-0E_OME::-Enjal2E1 CORROSIVE TO ALL TISSUES. MUCOUS MEMBRANE AND ESPIxATORY TRACT IRRITANT. ALLERGIC REACTION MAY CAUSE RESPIRATORY OISTESS. 1 IMMEDIATELY FLUSH WITH COOL WATER FOR 15 MINUTES, CALL A PHYSICIAN. IMJEDIATELY FLUSH WITH COOL WATER FOR 15 MINUTES, CALL A PHYSICIAN. IlmEDIATELY DRINK LARGE QUANTITIES OF WATER. DISCONTINUE IF AuSEATED UP UNCDNCIOUS. DO NOT INDUCE VOMITING. CALL A PHYSICIAN. I1MEDIATELY REMOVE VICTIM TO FRESH AIR, CALL A PHYSICIAN. t° SECTION-6 TOXICOLOGY (PRODUCT) ' A L:UIE-.).rLL 11 c:O: 2408 MG/KG (RAT); HARMFUL IF SWALLOWED. : NG DATA F.P mIXTURE 0 DATA FOR MIXTURE CI.LC NOT vifiiiN TO BE CARCINOGENIC tir:o Iar:C:NO JSHA:JO JAG:TULL:HIM: .' Ntir KNO:VJ Tj RE mUTAGENIC P-2008 .„) FUJI HUNT PHOTOGRAPHIC ,HEMICALS, INC. WEST 115 CENTURY RD. • P.O. BOX 988 PARAMUS, N.J. 07653-0988 :ATALJG HO: 91:4877 PAGE: 4 OF 6 :Y__1SS1IAI.L LL CIJRROS IV E J , FUJI HUNT MATERIAL SAFETY DATA SHEET EMERGENCY NU: 1—(800) -424 -9300 CORROSIVE laILICILAL-i1JUILL.UE-ALUEEIILUI SKIN CONTACT, INHALATILIN, EYE CONTACT, INGESTION :EL:LIS_1:IE_A::UIE_ :1E25LIEE1 CORROSIVE TO ALL TISSUES CONTACTED. IRRITANT TO •!UCLUS h;EMBRA ANO AND RESPIRATORY TRACT. ALLERGIC REACTION TO SULFITES MAY :RUSE RESPIk4TJRY DISTRESS. E:4=LI5_2E_C EJ_'IL_EIE_'S1/SEI NONE KNOWN OR REPORTED. ,- J: * *-;•{: .MsF 4f�:a a;s *,!,,':a!tXt*, ste s; s*ska;:**,* i! ese a; s*s;: *ae: ks ;<*:kafY,c* *aeya,;csye**1*>Q ** * * * * ** SECTION -7 SPILL OR LEAKAGE PROCEDURE (CONTROL PROCEDURES) :,:,* ti+•:. ;:fit ;:;: ': a: •;c ,t:'• Y'• 'sa : a :ici •.;c:, : v,;c !•Y,c m e,: kacis:, *i,.issisjc,kilts!c:, Eft {: *stt vo,x,hi ipi, *iea;e*st: s( e:psjca4***}:*** *# * * * * * * ** ?LI1J:I_E_1_tAIL=_IAL_SELE ASE_OS- SEILL.I. :OR SMALL INCIDENTAL SPILLS AND LEAKS, WEAR CHEMICAL SAFETY GOGGLES, AND iEOPF.ENE GLOVES, AND APRON OR COVERALLS. FOR LARGER SPILLS REQUIRING EMERGENCY :ESPONSE, NEOPRENE SOOTS AND RESPIRATORY PROTECTION MAY ALSO BE REQUIRED. FOLLOW 1SHA REGULATIONS AND NIOSH RECOMMENDATIONS FOR RESPIRATORY USE (SEE 29 CFR .910.134 AND NIGSH PUB. B7 -108) AND EMERGENCY RESPONSE (SEE 29 CFR 1910.120). ISOLATE AREA OF SPILL BY DIKING. STOP SOURCE OF LEAK. ADD DRY ABSORBENT. CLEAN JP AND PLACE IN 4N APPROVED D.O.T. CONTAINER AND SEAL. WASH ALL CONTAMINATED :LOTHING BEFORE REUSE, AND DISCARD CONTAMINATED LEATHER SHOES. : at s! esc�tdt a4. *a;:s':s;c+je** ha ::R:j *,!,a'tstsy:s':a4ata,4:ye** e t k sf; i e t t r AA '.tak c srt e i SECTION -7A SPILL OR LEAKAGE PROCEDURE (WASTE) :i.es'cic u , :aka;: t: ei ,:scs' :u* ,4 * ** cep.:4.4ak * tY.c t44* * * * ri 48 *** **fj 0#* **s}csle***: !ASIE_2LiEJSAL_MEIM2D1 •ISPOSE OF CONTAMINATED PRODUCT, EMPTY CONTAINERS AND MATERIALS USED IN CLEANING JP SPILLS Jk LEAKS IN A MANNER APPROVED FOR THIS MATERIAL. CONSULT PPROPRIATEFEDEPAL, STATE ANO LOCAL REGULATORY AGENCIES TO ASCERTAIN PROPER I I SPQSAL ?ROC DUE S. : :''+' ^;t: t�:s•i::;: st i :'_ • ;c :; > t�'c >cs•:i h:;:a,:a!:ss.* :acIca;cs`:: ryc aca;sa; cats; ca;<s s* M4: i± c:, Y: 4sksks! t4>, lcak *3;t#: s(.:;: ** !C:!C>;crF:jts'esisifr SECTION-8 SHIPPING DATA •ati:+ s a':• Ic:°ca't ** 4ei,• Y:*2.314ta;,*,:, ;:a!:q*);:;f '* ars(, e*► X>.>' i#: a,< at *a! c*a'e* *: *sta;tzic:QC *** * *t ;3m(ISIVE LIwUIC,N.G.S. (CONTAINS: POTASSIUM HYDROXIDE, POTASSIUM CARBONATE)* t"JT APPLICABLE , UN 1760 ..: i': , .1. .i ..',•' •.'C .f*!'1'it7• rscar :tac> ak>:s:<a`:st:;rt s�:aks';afs� :t; :k sr �a�C:�t::s,tack•a<sFa;t><;akit it�s{tifs�ta�ts�cac:tski SECTION -9 REACTIVITY DATA eAa,tsia; { : fc ;s =fa'eak-;t 4t ; t s;: a;:1, t• c* 0.** m sc *I v ae4c►, e* .; t** **4 **icA* * *_'t * *sje**sit *44%**s; IA::1L 1I'1 SIAL'LE_ X U L 9TT IP -2008 DECIL'E:5 CELSIUS, b1LL_VM_JLCUS . X DELIEEES EAIIEELIbE1 'HYSICAL DATA $P -2008 FUJI HUNT PHOTOGRAPHILHEMICALS, INC. WEST 115 CENTURY RD. • P.O. BOX 988 PARAMUS, N.J. 07653-0988 ATAL,'G 31:377 PAGE: iE= SiEll_LLihYIIYI 1.42 ( ;'IATEk = 1) =XPLOS IUN HAZARD - fXIC '. L !GICAL sr?LPE'TIES r ��IfIIY_ 5 OF 6 EXCESS HEAT itILinIIi::I1.1IY_ STRONG ACIDS _ CARBON DIOXIDE, SULFUR DIOXIDE JELIIi SI = =ir I_ NOT APP L I C A F L E ajLINSi_E0ICJIi> 212 DEG. F ILDR_r== s3H:'L �? NOT APPLICA3LE ElELLitiL_EDibI? < 32 DEG F ?ELSIIY_ 1.42 C; /CC :DEEFI :I:.gT_tir_' _Di5IEILLITIDti? NO DATA AVAILABLE aIu_I!ziili:�ir_I.LJL= ruE,FI NO DATA AVAILABLE :LEL SI:::1_LJAI:' __i: IiSiIIY .IIY_ID_yELNALIILAL_ILIEALII NONE .IEL= :ii -1L'_LcI ,___ 5:..' S111YIIY_IL_.5IAIIL_DISLbAELEI NO DATA "'Ei.cI_ F\CN DERMAL OR INHALATION EXPOSURE MATERIAL SAFETY DATA SHEET EMERGENCY NO: 1—(800)- 424-9300 :i:. Yc::.c); *.f,ca<* ; :.!, ; i a;c:gi4* y c)',::; c*a;<' c: 4ma4*) F**:4:: c:fs **Z ** SECTION-10 PHYSICAL DATA . .,I:)c':ic: .::::'a_.71:c* ;ca:c;c:`.:; v* , :); ::.?ri.;** :) 4c40:1*)!e*:jc:; *,t,*i<-!tr :!s: *,',: : 9;.:ti**1;4** ** * **** YAED3_EiESLUEEL APPROX. 15 MM HG iDLUt2.ILITY_IL__ COMPLETE EILEALIOSI APPROX. 12.4 LL'LAI.IL APPC\OXII'ATEL'( 6C :Y9ED39IiL'il APPiOXIMATELY 1 (WATER=1) LAELE_D_sIIIING DATA (AIR = 1) :x,e,' :- ;• >::; :: :.0. 4 :t:.< va .q* :*ak****AY.<)(e ∎cii: *tc4c:1 :e e);t**•'c4 *)k**•OC)K* e*:fs*s«e*)!e * * * * *** * * * * *• ?!t* . ; ; :)Y, ,c ': : .:{ c);: Y•. c• : :,:: A e l *: .:'cY,: **,: k1: a ,4 **elloi( *itv*,;,4t {c*:j:a *:i.c ;c:t:ytajsa;: : 3e> t** No c))t*aF**** *is>(•*)4**7 SECTION -11 CANADIAN ADDENDUM :;:ie:: ::S:: t :'e ;exs;e :;sze+;s:':ic *'ce:Y_ k :Ya:ic:(sr: :,e**d,.:'t:'c**>: ,: i,e%:,sd:*Mits>!e)kshyc****, s}:ka' - jeas*',k**24400 * *** * ** ** * *** *, FUJI. HUNT PHOTOGRAPHIC I.IEMICALS, INC. NEST 115 CENTURY RD. • P.O. BOX 988 3 ARAMUS, N.J. 07653•0988 ATALOG NO 316877 PAGE 6 OF 6 4P-2008 MATERIAL SAFETY DATA SHEET EMERGENCY NO: 1—(800)-424.-9300 JOT KNOAN OR REPORTED IOT KNOWN OR REPORTED ILLE_OE_IDZICULCLICALLI_SINEi.GISIIL_PEQUILII IONE KNOWN *vvi---- 1.4 • FUJI HUNT PHOTOGRAPHILCHEMICALS, INC. WEST 115•CENTURY RD. • P.O. BOX 988 PARAMUS, N.J. 07653-0988 :AT;1LOG 'I'; : 746001 PAGE: �U L , AJSC."tJt -T J • :;1e.• :a'::,:-Vsc:, :i'. •'• * t +c :k **2i.?*1: ,:cts?c , * plc: 4: tes' eY: a+•*>1:>;s**sF*al::ka(:> *1F *** *ki**a a'eaje** at SECTION -1 IDENTIFICATION fir. ;• , ?c-;c:,c., cMr ars ':, :**V:it0c **%4s,` *14**2!c** * t �C. s rksF 44* *** �** s s!: # # * ** +f �, � •� k. # #3k; * #�is #�'�es{eacta;eie } rF+Fciegc�:ie #�ti # #ak ILAL= _16DEi 'JEGACOLL'R LR DEVELOPER/REPLENISHER, PART B :.Ia =: PHOTOGRAPHIC DEVELOPER/REPLENISHER (TRADE TRIALED AS CT -312) ,:r 1C6L_rdCiLY: :MIXTURE �bE�I�AL FfR MIXTURE alEL'ILLL_L!= SL= IEIIOj: CLEAR, COLORLESS, ODORLESS, AQUEOUS SOLUTION :A5_:1041 NOT ASSIGNED /MIXTURE s•r: 4• ,tr >.a, cs'ca: •; taa}: s; csi: c*a4 (: ic:ia'c>;ssks(caksta;c**4! sfat:a!: c of * scs4 sh ska c i * ** * R ##+Gcn *• # � *# ie�sk , �- :{¢.f # ** # aR t� Vic. <s;c t c!c a' SECTION —2 NORMAL HANDLING PROCEDURE •7, *:tX:r;•it.e0.,'cr :s e,i, 4e :>. i s;: s *ica;•*41 7 s; cs+ 1*** **sficahskal<*hs*aic**** *fit ,t #*s * **:,;* **4 : _3�L.j'I1:: `1S_I- '-= c_IA1r= r ;_ILt_l�gL�OLiL�S_ALL_SIISAS�L3 30 NUT TARE INTERMALLY. AVOID CONTACT WITH SKIN, EYES OR CLOTHING. UPON :UNTACT WITH SKIN OP EYES, WASH OFF WITH WATER. AVOID BREATHING MIST OR VAPOR. STORE LH A C( L, L Y, WELL—VENTILATED PLACE. AVOID HEAT AND CONTACT WITH STRONG ALKALIS, STRONG ACIDS, OXIDIZERS AND HYPOHALIDES. HYDROXYLtMINE SULFATE :RYSTILS (L) IED LIQt1ID SPILL) CAN EXPLODE AT 265 F. F• DI_ � i1 Y:. _L:I11P:�LJS: C H E N I C A L < <E S I ST ANT GOGGLES .11. =EL: '4F(JPp.,. NE NE'.10RC'rE AP)..'JN IECHA'JICAL EXHAUST VENTILATION RECOMMENDED TO MINItMIZE EMPLOYEE EXPOSURE. I.:c•.. . HP -2008 70040700 ATTN: JIM NEKTON FUJI TRUC'JLOR PHOTO, INC. 13320 E. FIRESTONE BLVD. SANTA FE SPRINGS CA 90670 • rFALri: i'.E �L tai c_ 2 1 OF 5 REF: FH003 MOD MATERIAL SAFETY DATA SHEE EMERGENCY NO: 1— (800) -424 -9300 j ry ` 1 FUJI HUNT INFORMATION P.OVIDED BY: FUJI HUNT PHOTO CHEMICALS, INC. PARAMUS, N.J. 07653-0988 TELEPHONE: 201-967-9603 DATE ISSUED: AUGUST 12, 1992 DATE PRINTED: MAY 19, 1995 FLAtIABILITY: 0 REACTIVITY: 1 PROTECTION: C FLAr+I1ArjILITY: 0 REACTIVITY: 1 SPECIFIC HAZARD: c.+, .s• :+ ei• s'•; c:,+; c,,e {e.crctcs'Isere:,:r1i.:.¢Y• ::; ea;: ieY •.:;cst:tl+C):::;IYc fa?•;e �r4e: F*:{ es: c*s }•Vcse.kfiy>4t,t*shoka%ye - 1UJI HUNT PHOTOGRAPHIC- .:HEMICALS, INC. /EST 115 CENTURY RD:. P.O. BOX 988 ARAMUS, N.J. 07653.0988 ATALOG NO: 746001 PAGE: 2 OF 5 U3A5t.1'3LY LF: 016th SECTION —3 HAZARD INGREDIENTS * ,c:;i , •'r� mi-A.4:c *wA r:c: :*1:; ;: ;c* ic:{:***=.6>; elk. k*: ha;•: * xtYc + #rc ic**vc!c:k**:, * * d t Vic► kt* 9SIL_L"9I__'ILL1 HYDRUXYLAMINE SULFATE 95_J _ 10039 -54 -0 St!il_E LI "NONE ESTABLISHED L_SQ? NO DATA LL NO DATA ILUIEILAaI_EEEELI53 REPEATED CONTACT MAY CAUSE ALLERGIC SKIN REACTION AND /OR NEiIIA, '1HICH MAY LEAD TO EFFECTS ON SPLEEN, LIVER AND KIDNEY. MAY BE MUTAGENIC. PHOSPHONIC ACID DERIVATIVE AS_V 2809 -21 -4 S LL _E1 L3 NONE •ESTABLISHED MATERIAL SAFETY DATA SHEET EMERGENCY NO: 1 (800)- 424-9300 EEECEL : 10 -15% EEfiLEbl_ 1 -5'4 '..., .: FUJI HUNT 2.9 G /KG (ORAL—RAT) LL_ : NO DATA Ir CORROSIVE. TO EYES. IRRITANT AND /OR CORROSIVE TO SKIN, UCOUS MEMBRANES AND RESPIRATORY TRACT. 95IL__ PHOSPHONIC ACID DERIVATIVE, POTASSIUM SALT A5_,ALL1 67953 -76-9 eEELEtI. 5-10% Sba_'LEL_ NONE ESTABLISHED 1_5O_ ND DATA LL_E(13 NO DATA IGNIEiL_•_II_EEFELI5_ CORROSIVE TO EYES. SEVERE IRRITANT TO SKIN, MUCOUS ENBRANES AND RESPIRATORY TRACT. , ASiC_AIE i9L_ WATER 3S_IO,_ 7732 -1.i -5 5b. _EIL_ NONE ESTABLISHED `_SQ_ NONE ESTABLI SHED t1 NONE ESTABLISHED e_3C JII BALANCE LL_EQ? NONE ESTABLISHED :c:; t*s; .,:i•+ }+;:;: , ; VAJ:2:14 c trt ic>;:+k**. ic: Axcl sic ;: ;c*is #+icatiylm:{<*c; ** , rc*i.: �t�,c�axc h:Fc:t * *44c! *** *)0 *v * *1,4 SECTION —4 FIRE AND EXPLOSION HAZARD DATA :,•a i .. , ..•.. ., ' >;M **P"R*Wic:'ci ' <•. ' * c�!•o u(Ac c , � cr• t�jc �: � �; * *X' c: c*It ifYfA:, c*: yC*4%: c# *** + f>% *i;:: ic*:cc:f < *A***:;c*:fc:Cci4 _11FTJ012: NCT FLAMMABLE LLrin? N/A i!22E21 N/A iKYPA•!`i!!ti� 4 �:�u n�..,.H Y'}la�e.w. .......__....._ .. FUJI HUNT PHOTOGRAPHIL- CHEMICALS, INC. WEST 115•CENTURY RD. • P.O. BOX 988 PARAMUS, N.J. 07653-0988 :ATALJG NO: 745001 PAGE: 3 OF 5 4 IJA J J.- ,_ ._1 • Q1c0 7� 151'ALA. NOT REGULATED (NON- IGNITABLE) :ATj: CHOOSE EXTINGUISHING MEDIA SUITABLE FOR SURROUNDING 'ATER I ALS. iE:.LIsL_ =1: WATER SPRAY SHOULD BE USED TO :OOL FI;-:E EXPOSED CONTAINERS AND /Ok TO DISPERSE VAPORS. WEAR NIOSH /MSHA ,PFROVED POSITIVE PRESSURE SELF — CONTAINED BREATHING APPARATUS WHEN ANY MATERIAL IS INVOLVED I •J A FIRE. EXPLOSION HAZARD EXISTS IF HYDROXYLAMINE IS LIBERATED. ;:'c i',1! .:;c : •'c >. :ci: , 4 : :�:c fi.;: !Ash 4 1ta:i < ft ** r ti tYt**** * c ** * ' * o' m * c * c SECTION -5 HEALTH HAZARD DATA t: c• ,,,,e, rr:, tY, cati v;<:; c*ak*** *;%* **:* *'{eaFYc ctkia** tic ;c*:(e*:;c)0***:4***** c t �afrFAt # *�If� #� r= EECES "ELL_LIW.I_Y.L,1E_ NONE ESTABLISHED FOR MIXTURE. amEILt15_1.:E_OYEE_FZSE:15l1REI SEVERE IRRITANT TO SKIN, EYES, MUCOUS MEMBRANES. ESPIP.AT]4Y I WHEN INHALED. MAY CAUSED ANEMIA, LEADING TO EFFECTS ON SPLEEN, KIU^■E•f. AND LIVER. REPEATED CONTACT MAY CAUSE ALLERGIC SKIN REACTION. IsIN: IMMLDI. \TELY FLUSH WITH COOL WATER FOR 15 MINUTES. WASHING ANY SUBSTANCE 3FF OF SKI't IS A GOOD SAFETY PRACTICE. CALL A PHYSICIAN. :YES: IMMEDIATELY FLUSH WITH COOL WATER 'FOR 15 MINUTES. CALL A PHYSICIAN. LNLESTIOLJ IN CASE OF INGESTION; IMMEDIATELY DRINK LARGE QUANTITIES OF WATER. )ISCONTINUE IF NAUSEATED OR UNCONSCIOUS. DO NOT INDUCE VOMITING. CALL A )HYSICIAN. LLU LAIIWJ1 IMMEDIATELY REMOVE VICTIM TO FRESH AIR, CALL A PHYSICIAN. :k* •e'; .: ::ti ;p,c.;e :r:f-4iA :0icn*;t:!er;cic ;e* A4* *ri; cY, e** * * * * **fe*it*** * ** * *** * * **%r%ic**4******** SECTION -5 TOXICOLOGY (PRODUCT) :a,.. . 4r< :i si:'ei ai. •.;:r< :xc:,esee;::h*:h>: * *,:t:fe►: * * * *dercr;< *4 * *Y. *:eNe*** 2$ *****:;eA#* * **1. `/D FOR MIXTURE. HARMFUL IF SWALLOWED BASED ON CONSTITUENTS. ;s:;!I:_aEtjAL_LL_51: NO DATA FOR MIXTURE ?LUI:l_I_it19L_LL_L: NO DATA FOR MIXTURE :A= 'r1jL•='1j1;: NOT 'CN(1WN TO HE CARCINOGENIC 'JTP : NC I ARC : NO OSHA : NO ING;• : vALL MAY 5F mUTAt;ENIC BASED ON HYDROXYLAMINE SULFATE COMPONENT IRA ITANT I R R I T A N T :E'LJEL L__L'JI_S_a_A::S2EEIj^:JJ_ DERMAL, INHALATION, EYE CONTACT, INGESTION. FF r _Aj:t re" _�S►�'f'51�5"�i SEVERE IRRITANT TO SKIN, EYES AND MUCOUS MEMBRANES. 'ESPI ", T'i.'Y 4hE.'4 INHALED. .r`r:TC .t� :�_i1i. REPEATED CONTACT MAY CAUSE ALLERGIC SKIN REACTION HP -2008 1 FUJI HUNT MATERIAL SAFETY DATA SHEE' EMERGENCY NO: 1-(800)-424 -9300 =UJI HUNT -PHOTOGRAPHIC- C HEMICALS, INC. VEST 115 CENTURY RD. • P.O. BOX 988 'ARAMUS, N.J. 07653 -0988 AT. +L::IG NO: 746001 PAGE: 4 OF 5 .0b45JCMOLY j - : 71or3 /d NO/ ft ;1 I A LEADING TO EFFECTS ON KIDNEY, SPLEEN AND LIVER. ' '• ' FUJI HUNT MATERIAL SAFETY DATA SHEET EMERGENCY NO: 1—(800)- 424 -9300 *':. s,: i ::s;: :••:i: • • <s; :.•'ea;ci•:Y rt ia4a': r: aF;,; aX:!; a; cs c:; ests;cs;:x :Zesk*st:;t>S: <ut! s ;t str?::!t:lrsj:k 41.*s} 4 *kits't:+f=ftk*ik**tA:;t'4C* SECTION -7 SPILL OR LEAKAGE PROCEDURE (CONTROL PROCEDURES) 7 : :1: :'l •;:r t*• • Si+v1; ::,r***ar*, ***1:.**** it#***s k: 4.4( kc i. yc :r** *k*:f* #syt**v**** ******* se *** •CILCJ_E "AIEEIAL_2ELEASF_23_SEILLI UR SMALL INCIDENTAL SPILLS AND LEAKS, WEAR CHEMICAL SAFETY GOGGLES, AND !EGPR'_NC GLOVES, AND APRON OR COVERALLS. FOR LARGER SPILLS REQUIRING EMERGENCY ESPONSE, NEOPRENE BOOTS AND RESPIRATORY PROTECTION MAY ALSO BE REQUIRED. FOLLOW :SHA REGULATIONS AND NIOSH RECOMMENDATIONS FOR RESPIRATORY USE (SEE 29 CFR 910.134 AND NIOSH PU6. 37 -1013) AND EMERGENCY RESPONSE (SEE 29 CFR 1910.120). SOL,TE AREA ;]F SPILL 8Y DIKING. STOP SOURCE OF LEAK. 'ADD DRY ABSORBENT. CLEAN P AND PLACE IN AN APPROVED D.O.T. CONTAINER AND SEAL. WASH ALL CONTAMINATED LOTHING tiEFU E REUSE, AND DISCARD CONTAMINATED LEATHER SHOES. :s: :i :�<i:.;t:ps; sc :' e$et i..* s ;:t!r:'ti<e #stiaaae*sk:!e*>;: csfsf>, cs]e sj: sk**:;c:ksh:F:►4,;c***s;r ;t** car>;:lt}:***** * **el *** • SECTION - 7A SPILL OR LEAKAGE PROCEDURE (WASTE) :* *rc :a)a,r3,:;:•k*a,: •ls;s*4aesfa,:it: a4 ** ******it (*s!ca;C**sf **aV,4s;:aj ** s �e ** >' i/ :e s s• * s a4 f ' ;F sk �f of �- �t f # , # s}� � # �f s'f # k f ,c # k ASIE_ILLa 2 A _ {_+EIEOEs ISPOSE OF CONTAMINATED PRODUCT, EMPTY CONTAINER AND MATERIALS USED IN CLEANING m SPILLS OR LEAKS IN A MANNER APPROVED FOR THIS MATERIAL. CONSULT APPROPRIATE EDERAL, STATE AND LOCAL REGULATORY AGENCIES TO ASCERTAIN PROPER DISPOSAL RDCEOURES. 4 * *,1- ! s!: ' ,:,!::4J,:a;:>ti * ; ca4�t>' f s t :i,:s' it :+;c** s't** c ac st s4•�:s(csk>(c** *:;c:h ** c* 7 rs4 r :,:: ak # � �# , #�� � ## f #�I i;�k+i #eft #*#ak # # #: SECTION —S SHIPPING DATA ss'ss.; .;c? : �. ;ta!: %.;c *A7' : is ':a'e>t:(c*a;r*s;es;cse*4*. fir** . a'< *; a>3es;t>,'ci :*ii*s;esk** 4 *** •*** * r i t CI_rLAS_ URROSIVE LIQUID, N.O.S. (CONTAINS HYDROXYLAMINE SULFATE) UN1760. ��I_SIAI CORROSIVE TO STEEL. a,:s,. . s,c ,'• s;rh + : :; s;< c *1: y; +;c *:;s*s;: s; c is****** s;: Orst*#*} it icl** *it****:fit*s;:3c.::sc ,r a;t #* *s;r !,* # # #* #** SECTION —t) REACTIVITY DATA i : :+,: :a:a;: : *:�•i +,;:i:s; , ::# a° Y:;<s ts; rtt:: t: 1:s' r::; r afa; :***s;e **a;c:;c, tats} Est* icsr: t. k% fif* :cticst af**sks;:*sl**:;,*; I_!�jLIIY 1I3jLE_ �LJSI:3ELc: X 9I3 aLLEEES LELISJS, 265 AL'' ' n"" 1 S OAY_CiLLI.= )I,LLL_►:IEI_OLLUR_ X Tit AV ^jf: EXCESS HEAT (DRIED CRYSTALS CAN EXPLODE AT 265 F) STRONG ALKALIS, OXIDIZERS, STRONG ACIDS, HYPONALITES cL9ID,: S1S_1FEL HEATING WITH ALKALIS MAY RELEASE HYDROXYLA,MINE AP'�RS. 4r1 :lr:NIA, NITROGEN, NITRC'US OXIDE, PHOSPHINE, PHCSPHUROUS 'OXIDES tP -4008 LESSEES EAbEEWEE: :.r•: ,'r isa,:k-' ca%: .esxipi:m;ts'rs y: iti �r gFaysi st s; ts, es: s irir s;:.4.!e:4sra;t4tts4**4gc4, 444,44,4 SECTION-10 PHYSICAL DATA t: :''+'ri :sL ss,:a?: >;:a'• � s ":;,4 ;t...a: res•.a; i!. ✓c:,<a;�:�c:k f<s;:sr �ssts,c:t;Err:.asa'rr':rit #:l. tt><: a;:!<:+:,+ ts�. {:s;::�rsyc� <�cskr<s;ca;ta; s; FUJI. HUNT PHOTOGRAPHIC- CHEMICALS, INC. WEST 115 CENTURY RD. • P.O, BOX 988 PARAMUS, N.J. 07653.0988 :AT,L .1G 'Ii': 746001 PAGE: 5 OF 5 J�J •1 Jv • .•LT J1• • • � .V SV _�ELTI�tL_r ii!Ii '101. APPLICABL_ 1.19 YAPU1r_PEES :MEI APPROX. 15 MM HG ( :.1TL;i = 1) :i'Lua1L1TY_IJ__A.t . COMPLETE E_EACIT•J$i. 3•63 YUL!IIL I3 APP;' 754 ZILEUfiAIIDU_EAIDs_ 4PPDX. 1 (WATER =1) iA?ry_°_D= 0_iIY_`;tT APPLICABLE = 1) s:111 :::t7'.: '•7•:'•11 • ;. { • ;::;:: : ::;cr:a'; +;eic7;:ie:? ::;•.* * ;:c lyic.x t“∎*: It i+ ,;e** *a,? )it >t•**rk*ctc* a:c:lts(c>cat7 »3t 7c*ac*il:rf7{ * Nt ;t*) s*1k>fth* SECTION -11 CANADIAN ADDENDUM 'e r:c :fit 7;e 7;: .4 i e t re a4 i e e.• :;t>' a ih * ie aft * th re * Y ak>ie ;e >(: rl,: Ye r}s ix;:.}c ac e.�e rt :It�i•�eiFmrc�c•F� keif•)t *7ia`e:4 DHYSICAL DATA 7 pYy ,, !x : tit: ki•::; cit*: k:; ca;: s' s.; t7F7fcs! c: h4**..7, < ;:iF:4 >jci:*shrtst:,.:{f{ 212nE: •JOU <LESS '12DL'_Ty5= 5 NOT APPLICABLE FEEELiU < 32 DEG.F 1E�ISIIYi 1.13 G /CC LDEEEILiII_UE_waIE3LL'1L_D1UEIl1IIDUi NO DATA FIRE UR EXPLOS IJN HAZARD •;:7!t L'.: : ,:3.). X: .. •l: is 7: :, , •'t�• JS a< :< aUIL_S�UiTI::y j_ =4TURE_ NO DATA IELJf4TL`!_! LLI___LEJ.5 IlYIIY_ID_JELLIANILAL_IL+EALII NONE _AE' S,1� :N ) A T a - SEYlSIIlYI?Y _I!? NO DATA TOXIC )L" ;G ICAL PROPERTIES ;,r,�•.::•r�.lf , 1:. .. :,ti•''t• :1••'C 7't7<: • �:7� . ;,E.51 . 7 . 12:411 1 ; , , TM v i►i!!LI: SET SECT I :PIS 3 r 5 .ENO h. L'E.:.':I:.'!:L?:1LIIY_ ;LINE 4,'!11,4'; :1b ?:'=` _�L_i..I.:JL.' " sii: uLLY _SYIi.�'.;iISI1L_t?EGIZiILI? 4C.li <NJ4'l :HP -2008 iDILILQ_EDIJI14PPROX. 212 DEG. F. FUJI HUNT MATERIAL SAFETY DATA SHEE' EMERGENCY NO: 1— (800)-424 -9300 't •.•'. ,:7 . '•7,:s::.: t 1.7'Ir:2 :; 7 11, � fi 3,: 7 ;:; R�;. J 1J• 7,•:( d 17;{ i,< r' t i,•: �t .': ^7r : a!1f;r7,::/'AtI,I 7j j::k 7;t l,: rk >}7'/L rjt yt :7 �t �, FUJI HUNT PHOTOGRAPHIC CHEMICALS, INC. WEST 115 CENTURY RD. • P.O. BOX 988 PARAMUS, N.J. 07653.0988 CATALOG 'JL: 746002 PAGE: 1 OF 5 t ulcir, /t, 7;1040700 JI,I tvE•4TON FUJI TRUCOLJR PHOTO, INC. 13320 FI ES TUNE BLVD. SANTA FE SPRINGS CA 90570 r,:►•c;:,.a t:. ' r: '• :;4 '. i.:: ,s:.,e ��: :4:c:t��J.i�ik�:►:sr;:►; ; <�,tie t.'s: a {:J::;::�4.: %s,�s!.• :�: ;,:a rt:,edc: :z'..::4�: ;c dc►} �t�c:4gtY:ie t� <:) �* SECTION -1 IDENTIFICATION ie)'a,.•' ::. ....t,• :f• :t:v: •T: 7;!a't:\);tT ( t .;, 4 . .� =� �%. ta; *t: s: ac: ftc***?c*3:: *Y, tY: i, c- fi,: ifu: 4**:! t,“irc:;: :cy:***►;t*tt>yttt:t:tsj:f. ..IEAn" 'JEGAC :JLDP LF. DEVELOPER /REPLENISHER, PART C C;�E= 'ir.�L__t ►�.. "�; PiiOTOGr' APH I C DEVELOPER / <EPLEN I SIZE R (TRADE TRIALED AS CT -312) yLEL•1I_AL_ E:1►j1LY:. MIXTURE ;HP -2008 FUJI HUNT MATERIAL SAFETY DATA SHEE EMERGENCY NU: 1—(800)- 424 -9300 INFORMATION PROVIDED By: FUJI HUNT PHOTO CHEMICALS, INC. PARAMUS, N.J. 07653-0988 TELEPHONE: 201-967-9603 DATE ISSUED: OCTOBER 14, 1993 DATE PRINTED: MAY 19, 1995 REF: H0313 MOD LtJE"IIL6L F'' MIXTURE CtIE:'I!:9L_O1E2I1!'21 AMBER SOLUTION WITH SULFUR DIOXIDE ODOR NOT ASSI GND /MIXTURE :• �:•: , ..t , . .): :t:, :;t* ). :%),A t::;ti :}c► v.,:: tic:;:►;,; tc'<voxt:X:t*syis*:;t , q1, #c:k4**::►,t**:444.:4>}t*** SECTION —2 NORMAL HANDLING PROCEDURE ;t * if f1,c: lc:,: tc. c$ trtity< ic:' c:! t► ksita4o! t:;< t:► Fot; *> t4,jcif ►t4t**tt*:fi4 ►L EEELLULL: ils_I ' Intl_ IL'_N9 1�LIt1�_c��L'_SIi1Er1fsi:� HARMFUL IF SwALLU ED. AVOID CONTACT WITH EYES, SKIN OR CLOTHING. UPON CONTACT wITH SKIN .1r EYES, WASH OFF WITH WATER. AVOID BREATHING MIST OR VAPOR. STORE IN CflOL, Dt y, 4 LL—VENTILATED PLACE. AVOID CONTACT WITH STRONG MINERAL ACIDS AND W I O I Z I N G AGENTS. :YES: CHEIICAL SAFETY GOGGLES (FACE SHIELD IF > 10 GALLONS) 1L I'VE : JF_'.Jf 4F'Jk AP UN '_t',CftL tXNAUST VENTILATIJN RECOMMENDED TO MINIJMIZE EMPLOYEE EXPOSURE. J_!1� — 3 FLAHHA?ILITY: 0 REACTIVITY: 0 PROTECTION: C . : . m . .: ... :r 2 f' s r �,4�. :'t::.:,.: ao:n:t:c ;.►; "it►::::c >; > :� Acr,. :t:2.1: le X -PiA t;. *A P ■:' *tic SLCTIi1N —3 HALA' D INGF_UIENITS =UJI HUNT PHOTOGRAPHICQHEMICALS, INC. VEST 115 CENTURY RD: • P.O. BOX 988 'ARAMUS, N.J. 07653-0988 e T;:L:;i, 7 -oO72 PAGE: 2 OF 5 FUJI klUNT MATERIAL SAFETY DATA SHEET EMERGENCY NO: 1—(800) -424 -9300 1.. ;a, a,. , it:'s:;'e;: ; o;ei::;t�S , :,. :a,.': le:�.:; : ?:s.:+e••y:Y :i:;ea;•a,: : sa,:aap ae�us ;::{:�:a, {satatie:�r',trtt(.:�=>�t: PARA— PHE.'�YLENEDIAMINE UERIVATIVE, COLOR DEVELOPING AGENT A :J j : 2.:02)-34-0 EEELEJI_ 25 -30°: irY;:_ EST; 6LI SHED 14 mu/KG LC—U: NO DATA IQJIEELLL I_.EEECI.L_ (UEAL -RAT) h'I`•., FY: AND mUCOUS 'IEME1R +NE IRRITANT. MAY. CAUSE ALLERGIC E';"ITIZATION T[3 SKIN. S 0IUr•t SULFITE �S_LkJ. 7757 —„3 -7 Nr:M= • E S T AbL I SHED SEE -3E_L4 :ltd 14_5Q_ NO DATA 1. .1.Z1C_JI__EEELIsi SKIN, EYE AND MUCOUS MEMBRANE IP.RITANT. MAY CAUSE E Sr' I r. AT3'tY IRRITATION AND PULMONARY SENSITIZATION. ALLERGIC REACTION MAY CAUSE ESPI :'• TU7Y r13TrESS. 050: LOLJ = 2 3 ?5 MG /KG (ORAL—RABBIT) n.ATER cup, 0=1 : ''4L ESTAnLI SHED ';)NE ESTABLISHED I;iiT:i T_ZEE =CTS_ 'IQNC ESTABLISHED. EEECELII_ 1 - 5% pEE. E II BALANCE LC_Qi. NONE ESTABLISHED ..t n • ,r. ::.�.t >.:e' •%: s t:;.:. t: ri 4 ::;:::::.:: �qt: k► ,c ;:isYC 4� e;. #:f:ls:;oe ;e�t.:}ta:a(c�: *te.'es:isrh j:at**f':) )' :: SECTION -4 FI'ZE AND EXPLOSION HAZARD DATA y 1'• ... • : :t . , :cd.i.t :;: :;• ;. YI.,( < s;t: ],..:;Cl�tf;c7't7,:YS ;:s;tyt ,ta:7rc::=0:.a;:7,ca,tat.�Cac ** *a **A, al ,ta 'r4,0 L_H_= :1JT_ :;OT FLAMMABLE - LQriCE:. N/A i!E2E31 N/A c ,,. -t ��`1fiL ?'i::T': !ICT REGULATED CHGJSE EXTINGUISHING 1EDIA SUITAF.LE FOR SURROUNDING rr, _ r+ATER SPRAY SHOULD 3E USED Ti7 " L E [ :Y::'��•=� 12` :NTL.1t E'',S A'IU /cP TO 0ISPEKSE VAPORS. USE NIOSH /HSIIA APPROVED SI1 I�•'= 'Y� �;l! S::l..- CITAIAED PREATHING APPARATUS 'AMEN ANY MATERIAL IS IP -2008 WI HUNT PHOTOGRAPHICcHEMICALS, INC. /EST 115 .CENTURY RD: • P.O. BOX 988 ARAMUS, N.J. 07653•0988 AT;L N:J: 746002 PAGE: 3 OF 5 UhA.):)cNoLf Jr. olort, A FIRE. AICIY NOT KNOWN TO BE CARCINOGENIC NTP:NU IAC:NU OSHA:NO It,G;EOIEdT(S): '"ALL uraGcNIC: KNOilN TO BE MUTAGENIC CT:cROSIVE P-2008 ,... FUJI HUNT MATERIAL SAFETY DATA SHEET EMERGENCY NO: 1-(8O0)-424-9300 CUI'- N/D-MIXTURE. HARMFUL IF SWALLOWED BASED ON CONSTITUENTS CUIZ_DE2LIAL_LO-51.11 NO DATA FOR MIXTURE LUI:_iNUAL_LC_OI NO DATA FOR MIXTURE a.. 0;:* SECTION-5 HEALTH HAZARD DATA 11PrQJIA.:: _ NONE ESTABLISHED FOR MIXTURE. XIi ov,-7P lEnalP!I CORROSIVE TO EYES. SEVERE IRRITANT TO SKIN AND UCWS mEN3RANES. REPEATED EXPOSURE MAY CAUSE ALLERGIC SKIN REACTION. tJELU:i!JLX_EI2.:5I-AID-22ELEDUEEa LIL; IMMEDIATELY FLUSH WITH COOL WATER FCR 15 MINUTES, CALL A PHYSICIAN, IoHEDIATELY FLUSH WITH COOL WATER FOR 15 MINUTES, CALL A PHYSICIAN. 11 I'J CASE OF INGESTION; IMMEDIATELY DRINK LARGE QUANTITIES OF WATER. ISCONTINUE I= AAUSEATED OR UNCONSCIOUS. DO NOT INDUCE VOMITING. CALL A HYSICIAN. NdALaivjm: IMMEDIATELY REMOVE VICTIM TO FRESH AIR. CALL A PHYSICIAN. SECTION-5 TOXICOLOGY (PRODUCT) SEVERE IRRITANT .011.1Tc; P.50 DERMAL, INHALATION CEELII_JE_LC.IJIii-EIE1:5AJEEI CORROSIVE TO EYES. SEVERE IRRITANT TO SKIN AND uCudS mEmnlo\AZS. RESPIRATORY IRRITANT. ALLERGIC REACTION TO SULFITES MAY CAUSE ESPI!Tr.I;Y OISTRESS. ELECII212.41C_EIP.Z5U2a1 c:EPEATED CONTACT MAY CAUSE ALLERGIC SKIN REACTION. SECTION-7 SPILL OR LEAKAGE PROCEDURE (CONTROL PROCEDURES) _ ' 711; _ .52ILL1 sIALL I C UiTL S} ILLS AND LEAKS, v CHEmICAL SAFETY GOGGLES, AND GLHv:S, A APPF)N UR CUVE"ALLS. FOP LARGER SPILLS IRING EMERGENCY :c :. .. .r• •• :HP-2008 FUJI HUNT PHOTOGRAPHIL CHEMICALS, INC. WEST 115 CENTURY RD. • P.O. BOX 988 PARAMUS, N.J. 07653.0988 F HUN MATERIAL SAFETY DATA SHEE1 ;t•Tt.L•JC ;L: 74o)O2 PAGE: 4 OF 5 EMERGENCY NO: 1 •424 - 9300 `�� :::'I is ► �'!= •E:' += B=:OTS AND RESPIRATORY .1 OTECTIUN MAY ALSO BE REQUIRED. FOLLOW 'SHA "t�',;t!L.:,TI J "S AtlD NI!1SH RECOtiMENGAT1tlNS FOR RESPIRATORY USE (SEE 29 CFR 1./10.134 :.:t(; •rIJSh PU&. 57 -108) AND EMERGENCY RESPONSE (SEE 29 CFR 1910.120). ''r'L t •4T•_ L;�.: )F SPILL 5Y DIKING. STOP SOURCE OF LEAK. ADD DRY AEISOR3ENT. CLEAN J t !F AND PL ; .r. I I A': APPROVED D.J. . T. CONTAINER AND SEAL. WASH ALL CONTAMINATED F.0 L ri;E USF, AND DISCARD CONTAMINATED LEATHER SHOES. :;.. ...: ::;:>:>' * : a;.•' t ^,( t*** i:>;t * c; c> c: x: nt: j::!! 9:**rt>;r>ks :; *aj4; **. >i 4* =,v:** SECTION-7A SPILL OP LEAKAGE PROCEDURE (WASTE) :. .... ,a.,•*Ad<:;:s' *. .: ,: !tac >!*, r * 4x * c t::* * t ,A h�c * rt ,;c :c: � �;- ! :� %k #�!� �' tit% p�: �k# =� >k `Otis �h �� )ISPJSE , JF CU`ITANI'ATED P EMPTY CONTAINERS AND MATERIALS USED IN CLEANING •JP SPILLS •.'? LEAKS IN A MANNER APPROVED FOR THIS MATERIAL. CONSULT APPROPRIATE CEDE AL, STATc AND LOCAL REGULATORY AGENCIES TO ASCERTAIN PROPER DISPOSAL :=ROC_:.ru_S. SIR. ILiIY :i:U1:L =_ X ! !tjSILLE_ ALL . ';';T 1r'PLICALLE __L:LiEi ___L.Zi =Y_ 1.12 (!iATE = 1) C t'PLCTE /_i L T TL_:. :0 7fl`, , t:'•ita, *,vi i;t>:c* art>,;>; :4<vt:Ic.,c***).(.; tic: jcia:{ t*** *r,: a'::+.c f+K >t *;ct;:*>;t.,:>!ccttt**4 — SECTION —I? SHIPPING DATA r:'c •c::t .... :: , .: 'c_,c>; ::c >t :k:'ttt:; c dt►;t ,e:k>4i:>,c Yt' ci k •;• X' 4 :f:islr%r#> t :Icat: eta;: X:4: t( t:!:; cyc);c>: ats tC>; t*:Qt>!:: CO' U SIVE LI!:UIT, '+.1.5. (CONTAINS PARA— PHENYLENEDIAMINE DERIVATIVE) UN1760 k :,::.,ic :: •• 4 .'c :.. •i: ::; * tic:: c: 4s'/>::: {c“p.411,tiier:*tul :14t :sisjc*: *:lt>'<>;ts,'F* v* ti **** **: SECTION-9 REACTIVITY DATA v :: ; .. ; :••c : : :* •c: :;c :<:.•' #3, is 'c>;rf!!**i:>,: ;cstc:,: < :; s'fr:t.4 *,.c,;t**4** >itii*; **3,t>ara }s!tatsc s4a «********* **, L+AY_DS:.LDu _ IIILL-NDI-OCCUE1 X DELEELS QE EABEFNE: _TJ_�`Y:�I`�_ EXCESS HEAT STWO'NG .'1INE4L ACIDS, OXIDIZING AGENTS. 1 AL:;Yvi!aJ_+ ° :SIIin N PQ ( InULI_ SMALL AMOUNTS OF SULFUR DIOXIDE • . .:,::, ,:s' cs '•:• cX* Itr. Yc:` ,t>!t>;.,:>t• tie* . ); >,:yt,t>.c** *i. m****Y4t(t"fi;trt>;t* SECTION-10 PHYSICAL DATA >:::*••, .•c '•. ...t: *•'r, ; *:: X:: i>;*s ;:ar>'•:c >'sr:�•>'c�:•jt:c ;ei.> pie: i><>;:>' c>;:, 4sa�::;coFat>':>;to'cat:'tgcat> *, Jr% 1!+ X�hX' irKts ;cascY�t�:>;tt¢: ;ts�c>,c>�i II1LiLri:_?D.L I: AP °F.UX. 212 DEG. F. YAEJS_EEESSL!E'E_ 15 MM HG E _E_LIJL'i 2.44 iY�N;_3tIl:�Lt_�'t?IE_ 4PPPGX. 1 (WATER =1 ) 'WI HUNT PHOTOGRAPHI- HEMICALS, INC. 'EST. 115 CENTURY RD.'. P.O. BOX 988 ARAMUS, N.J. 07653 -0988 ATALOG 7.46002 PAGE: 5 OF 5 Uti:.JatJ :iLY tlr: AEUh_E_J -.IX 0 DATA (AIR .= 1) •, 7 r.. r• • :s ?:�;. �',, <� : ( ::r. :•;t :�*);: :s ::a:: t3 AI Y.4* 14:40:1* :k:s:ye * : :s it 30,4: t:;t:{:** s}*eV*e$1,1/4** :fir i , v .“.,a, �r:fe :yt*:?t* cat **,i4g -* 3.0. ;,at:kre' * : rts, Y**attf,::F+4ea;::;e:'t *,:4•1'>;: :%itsfses(tsf*:k{k*rt.t **u. SECTION -11 CANADIAN ADDENDUM •i, ?'<rr, sts,,s :,t te: rt :t:`:sr “"* a.*:'tsk =' +S'4•'}*> *411 *'*s! * tic='F:t*;a>,c**A* *Ii %m : its. * * * * * **i4** ** ** **,1 HYSICAL DATA 2]j';_ SULFUR D I JX I DE ODOR T� NO DATA JSI 1.12 G /CC .]EEEILIL II_LIE_ A1_aLOIL_UISIEIBUIIQUI NO DATA IRE fJF. EXPLUS ION HAZ AP.D LIIO:ILLIIII2U_IEtE:29ISlLE3 NO DATA 1EL_SIL 1_:_S= L5IIIYIIY_ID_1;1LLLIAL 1LAL_I!JQLLI_ NONE IELESI:]:l_ ULIb_:_ SE , :!5IIIYIIY_I2_5IAIIL_IIISLtiAUE1 NO DATA • 7XICOL'JGIC4L PROPETIES J:�II1ZAIi�?�_I:]_?EL�llL2� EE SECTI:JNS 3 AND 6 F.EEMULLYE_IOILCIIII :NE KNO4N OR REPO:ZTED I . IJ1E_LL .LIY_ :NE KNON`i OR ►?EPORTEf Am' : IlAISIEL IIILALLI- .5XVLEGI5II.L_PEODULI_ .:NE KN71:4 r1P < P.1f' TED P -2008 EEE ZIUL_EQLUI_ NO DATA FUJI HUNT MATERIAL SAFETY DATA SHEET EMERGENCY NO: 1-(800)- 424-9300 : i;' . ..'• ... :,...:,: •i•'••:t;��:s';; ;: A:s' ta;:• ti4e: : /. /si;#41s;e* *4.s't11. :; <*t! sic: Jedt: k**,#: t;:•!;*> f> F*****ytut.'e*i;�re#e**ra {t* *fi Product Mixed I1eplehish0 EC NEG SUPERFLO'" Rinse 12 X 10 Liters 816499 6 X 25 Gallon 816500 Mixed lieplehlsher NEGACOLOR'" Stabilizer And Replenisher 6 X 25 Gallon 816505 6 X 75 Gallon 816506 600 Gallon 816507 Mixed heplehlsher NEGACOLOR" PlIgess lortel Stabilizer and Replenisher 12 X 12.5 Gallon 816512 EC NEGACOLOR'" ULF Stabilizer And Replenisher 6 X 75 Gallon 816502 300 Gallon 816503 Mixed (leplehishel- jle(t(� FUJI HUNT • PHOTOGRAPHIC CHEMICALS, INC. HMIS Information - Concentrate / Replenisher For Process C -41 Flam- Personal Part Health mability Reactivity Protedion Ingredients 2 2 2 2 2 0 0 O 0 2 0 O 0 0 0 O 0 0 O 0 TECHNICAL DATA C 8 Water C B Water Triuolc Derivative Proprietary Nonionic Surfactant Water 37% Formaldehyde Solution <45 Nonionic Surfactant <5 Water Balance C 379'. Formaldehydesokidoo <1 Water Balance C 37% Formaldehyde Solution <99 Nonionic Surfactant <5 Water Balance C 379'. Formaldehyde Sokrlon U Water Balance C Triazolc Dcdvadve Proprietary Nonionic Surfactant Water n m< Z v HMIS Information as of April 1995 For additional safety information consult the Product MSDS sheet. For Medical Emergency Call 800-424 Page: 7 Amount % • <15 <10 <5 Balance CAS H 288 88 0 Proprietary 24938 91 8 7732.18 5 Balance 7732-18-5 <15 <10 <5 Balance Balance 7732-18 Skin, eye, mucous membrane and respiratory macs irritant. (Under strong ac di: conditions (pl1<2). Formaldehyde may be released. May be a delayed con ate sensitizer. Prolonged ingestion may produce slight damage to circularxrt erythrocytes and non-specific adverse effeds on growth and mum motor syst Prolonged ingestion may also produce toxic effects upon the leer. None expeded Skin, eyes, mucous membrane and respiratory tract irritant. F 'LI 50-00 0 regulations for formaldehyde ealzeunr (29 CFR 1910. )048). Pote can .,r 78330 -21.9 hazard . Repealed orprolomgd 000sure increases the risk. Chronic eposun. 7732.18 -5 may cause respiratory sensitization (asthma) or skin sensitization (dennoruis ;. Dime contact or comsat to vapor concentrations greater than t1SILI PEI for formaldehyde may cause permanent eye damage. o Skin, eyes, t a4cows menabnowe and respf *tory tract irritant Folk 5 u 77 04100 5 OSILA regulations for formaldehyde exposure (29 CFR 191121043) Potential cancer hazard • Repeated or prolonged exposu tncr lbe risk. Cbroaic exposure may cause respirator) sensitization (asthma) or skin sensltlzatiow (dermatitis). Dina contact or exposure to vapor concentrations greater than GSI !A PELforforwaaldebyde may causeperrwamemt eye damage Skin, eyes, mucous membrane and respiratory tract irritant. Follow OSt LI 50 co-0 ngulasorss for fwmaldehyd• ea isms (29 CFR 1910.1048). Potential care et 78330.21.9 hazard • Repeated or prolonged exposure biennial the risk. Chronic citron n' 7732.183 may cause raspirnsory sensitization (asthma) or skin sensitization (dermatir s) Area contact or taprmarr to vapor cwaerwatiortt greater than OSILI PFljo formaldehyde may eau,. permanent eye damage. Skis% eyes, mucous membrane and respiratory tract irritant. Foao u 504:0e GSM regutations for formakiebyrk exposure (29 CFR 19112100 ) 7732.18 Potential career hazard • Repeated or prolonged exposure increases the risk. Chronic exposure may cause res oty sensilizatiow (asthma) or skin sensiltzeattom (der-math 2 coaled or exposure to vapor concentrations greater lb Ill PBLforforw.aIdebyde may cause permanent eye damage. 28888-0 Skin, eyes, mucous membrane and respiratory tract Irritant. /Muter wrong ad.'s', ... conditions (p11 <2), Formaldehyde may be released. May be a delayed corutc, 24938-91 E sensitizer. Prolonged ingestion may produce slight damage to circulator) 7732.18.5 erythrocytes and non-ssec& advent, effects on growth and mum motor rysre n Prolonged ingestion may also produce toxic 17.r81 upon the (ern. Nome expected Hazards Warnings To Order MSDS sheets or HMIS labels Please call 800-526-0851 Ext. 10 For Chemical Assistance Call 800-526-0851 1 •, FUJI HUNT PHOTOGRAPHI - t ; ;HEMICALS, INC. WEST 115 CENTURY RD. • P.O. BOX 988 PARAMUS, N.J. 07653.0988 i.AT.",LJG 1:3: 316502 PAGE: 1 OF 6 HP-2008 7`i J407C0 ATT'I: JI1 NEWTON FUJI T'?UCL'L:_lP PHOTO, INC. 13320 E. FIRESTONE BLVD. SANTA FE SPI.INGS CA 90670 e w , a:.. ita: ; aea <iea7c +ea': a't alc :?c:!t a: a;[i *t'::eke :e.' rte: a!:;'. t: j:s;: a} t:, til4ytl! , sed:4:ajtsf+;t:' f 3:xtst9�tif%x a slr** ' �e� itKt�t�•k�ifri SECTION -1 IDENTIFICATION ci:a;e? 0elt:;- a.:. * *.kt ***i. l- i sht a1ci'e ae ':' : > * * * sre - ho= ;AM : cC 'IEGACIJLOF. ULF STABILIZER AND REPLENISHER (6 X 75 GAL) '' " PHOTOGRAPHIC STABILIZER REPLENISHER (TRACE TRIALED AS CT-326-2) REF: FHU93 :dE:.�iLAL_1. LL1: `RGAN I C 'IIXTURE :11E LLAL_= SL?iEI12 l: CLEAR, AMBER, AQUEOUS SOLUTION WITH LITTLE ODOR .Et'S_`sfl� NGT .ASSIGNED /MIXTURE •* **. *• H q -a :d• ;i: , :'catac:!e ;•a;:a ;tift:rxa,`: ;< :ic:talc i,iF►; :** **iF# **kc* ic., y. u:, trFateh :( *30,!ttde:; *** * *: SECTION —2 (NORMAL HANDLING PROCEDURE :!ta' :. :,;: Y r :s : ! :wro: - i;►z>' ;e) y: i sa' e; cai; t; <*v4—•,:*/t:Ark:re:!t:ilei¢k: es3e***2 tat:!Y,ea',::!e ; c44'(t * * *** *4*31 !EMIUII:11L_Lj:...2_I.Ve.L21_1:J_JAjr.21-LL-LULL-5I0EAaEl 0EAL +AF:MFUL IF SWALLOWED DR INHALED. AVOID CONTACT WITH EYES, SKIN OR CLOTHING. UPON :ONTI CT 4ITH SKIN OR EYES, WASH OFF WITH WATER. AVOID BREATHING MIST OR VAPOR. ;TORE IN a COOL, DRY, WELL—VENTILATED PLACE AWAY FROM ALL SOURCES OF IGNITION. •VGI0 CONTACT WITH 'JXIDIZIND AGENTS, PHENOLS, AMINES, ACIDS AND BASES. UNDER :TZONG ACIDIC CONDITIONS (PH < 2) , FORMALDEHYDE MAY BE RELEASED. .ED. :Ii== _ �LL� 1 �_i Is .YEE_• C.-i i ICAL SAFETY ;. .. NE GOGGLES AKRON L>:JI1L. ITL_' - I:s! LL OCAL W I I C A L 'AFC I C :L XHAuJ ST V +►?(:;, !) i [ CT. — F•L1'.MABILITY: EEL — i' ..LT -4 2 F L A MATERIAL SAFETY DATA SHEET EMERGENCY NO: 1— (800)- 424 -9300 INFORMATION PROVIDED BY: FUJI HUNT PHOTO CHEMICALS, INC. PARAMUS, N.J. 07653-0988 TELEPHONE: 201-967-9603 DATE ISSUED: JUNE 24, 1994 DATE PRINTED: MAY 19, 1995 VENTILATION RECOMMENDED TO MINIMIZE EMPLOYEE EXPOSURE 0 z 0 PROTECTION: C 0 REACTIVITY: 0 SPECIFIC HAZARD: la FUJI HUNT • . .:•••• i•is t >;•t•.,; a, .e�. 'c ; • •.,1raz u.: a at a;. e o;: i;: rye ,a:e I:cie*of *It* :;e :;:xe:?e,f FUJI HUNT PHOTOGRAPHI& CHEMICALS, INC. NEST 115 CENTURY RD. • P.O. BOX 988 'ARAMUS, N.J. 07653.0988 MATERIAL SAFETY DATA SHEET ATALiJG '4 316502 PAGE: 2 GF 6 EMERGENCY NO 1 424 - 9300 SECTION —3 HAZARD INGREDIENTS :! : •- , _ 'C.• ��y... A �.J.�.��J..y::t] :%:, :e:' :! .,.sFs!: <�;::c >; ' *'i%t''; eta! j::jtYc t;c >:s'::''t:��:�t= k� <%1: 4 %F�::�t ** * �< %k* TRIAZOLE DERIVATIVE :AS_LL'a_ LA-38-0 1 S yy _ =L_ NONE ESTABLI SHED .Q_SQ_ >2,000 MG /KG (SKIN— LL-5Q: NO DATA AVAILABLE ligNiEIS4 FFFQTi_ SEVERE EYE IRRITANT. SLIGHT IRRITANT TO SKIN AND MUCOUS IFMCP ES. A FOUR WEEK ORAL TOXICITY STUDY SHOWED NCN—SPECIFIC ADVERSE EFFECTS ;N GF:UNTH AND THE WE:?O —ROTOR SYSTEM (400 MG /KG /DAY) AND INDICATED SLIGHT DAMAGE 'O CIRCULATING ERYTHROCYTES (57 MG /KG /DAY). 'RAT) , 1126 .'!G /KG (fRAL —RAT) :ASIL_= "AIEIL,L_ TRADE SECRET ,gSAQ,,: NJ TS REGISTRY NO. NJ 36559300 -5001 ?Stt&_EEL_ NONE ESTABLISHED 11,200 MG /KG (ORAL — LL_aal NO DATA AVAILABLE i iliElCA"I_EFEQTS_ SEVERE SKIN, EYE AND MUCOUS MEMBRANE IRRITANT. CONCENTRATED ;OLUTICNS 'tAY EE A DELAYED CONTACT SENSITIZER. . ) ,AS?L_ : NONIONIC SURFACTANT .AS_Y 2493 < s -91—m EEECL I3 1-5;; :SHA NFL: TUNE ESTAbLISHED i�_FQ3 N DATA AVAILABLE LC_EQL NO DATA AVAILABLE jQ!iiF1CA\T_FEFELTSc SKIN, EYE, RESPIRATORY TRACT AND MUCOUS MEMBRANE IRRITANT. ASIL_nIE =EIAL: MATER 7732 -19 -5 1�. .J l;c ESTA. L I ShED E T,::sL I SHFJ IL:;IEiL1.:I 'ZONE E STASL I SHED AP-2008 • ' _ FUJI HUNT EL2LEJI1 10-15% eESCE II 5-10% EEEL.::d_ > 70%: LL_FQ? NONE ESTABLISHED .•f,•.'0c:.+,t :::, .. : :'c � ci`•:C: ie� - y icf'c*: ; * A**,rie u :.c0,• ::�C .',•i:u:;t:c:, :tmrt:ktlfi c* ::}t**1;t*1?.4t X. SECTION — 4 FIRE AND EXPLOSION HAZARD DATA ..., .• , :.:;f' rrsi,: �t.. i,.Y:r! a ;: : : ' ro .:� :: .:;.1t:;: :ca: :, ` ,:j::,' *iticio! #5 c4*****:11** I:%, FUJI HUNT PHOTOGRAPHI6-%:HEMICALS, INC. NEST 115 CENTURY RD. • P.O. BOX 988 'ARAMUS, N.J. 07653 -0988 :t.1�,L:1G +•_�: +16502 PAGE: 3 OF 6 .La.2_“7__II__ ":.I UL_ 10T APPLICABLE :L:1 '__EL.:_ zEL:;Sly1__LIJIISi - L EE_ N/A LL_ELLSSIEIELII : NON— COMBUSTIBLE :?ill li; ciL_f_:J_EILL'WATER SPRAY, DRY CHEMICAL, FOAM OR CARBON DIOXIDE. CHOOSE XTINGHISHIi; MEDIA SUITABLE FOR SURROUNDING MATERIALS. iE_.IAL_ EIRE_ dALLKll _L"_EILE_EICtIII14_EEE'EEDUEEI WATER SPRAY SHOULD BE USED TO GOL F F:,_ E (POSED CONTAINERS AND/OR TO DISPERSE VAPORS. PERSONNEL SHOULD EMPLOY IIDSH /NSH. :;PP;.OVEO POSITIVE PRESSURE SELF—CONTAINED BREATHING APPARATUS WHEN .NY 1\TEP IAL d AS IGNITED OR IS INVOLVED IN A FIRE. TRY TO REMOVE MATERIAL T I N E F;-:2!'t FIRE AREA I F I T CAN BE ACCOMPLISHED WITHOUT RISK TO PERSONNEL. ,;:. �... . :. , . , :1:'c nr•>;:ici: ,:: *.i.,. * ; c? t*****i,c*if:t:{-**itA* !:! * tr y<*****:(c;f *** * * * * * * * *; SECTION-5 HEALTH HAZARD DATA i:ti;i': :'.:.r.. t ic:ci �•:.:�:>,e:' :c ita:: E� :�ci:�'ci:'x:i:�e�t:�t�ie:fcr; �c ",t :; tat;}: �.rff;::�c::;e�ts.:;:ie�;td•'cf i< ;t:t:fefc *�'�f�t **i >k * *� .!LEE:i1LL 1_LL 1I_V_L1__ NO DATA AVAILABLE. :VJ PTf'-+C uyFI_ SKIN, EYE, MUCOUS MEMBRANE AND RESPIRATORY RRIT4TI73N. 1 LEY_E1 =SI_ Al L_a'JC DUEES EL,!: IMMEDIATELY FLUSH WITH COOL WATER FOR 15 MINUTES, CALL A PHYSICIAN. .Y =Si IMMEDIATELY FLUSH WITH COOL WATER FOR 15 MINUTES, CALL A PHYSICIAN. .;JLE3I12y_ IN CASE OF INGESTION; DO NOT DRINK WATER. DO NOT INDUCE VOMITING. ALL A PHYSICIAN. NHAL Tj]t_ts I :1iEDIATELY REMOVE VICTIM TO FRESH AIR. CALL A PHYSICIAN. :,li ci :r , :i .. t::•::,: �,; �•�:ici'�idt7t: :t:;c�. <a»Ctt:kacac:t ' :fa is Ri;ta:i:+!to;::jta:`tttst �4yY a: 9 -4a •+,= . �,.�c�c�. 4�;c�c ;.c ►F ** *aF lac . SECTION—o T(XICOLOGY (PRODUCT) . :.,. ,c:.'ri t' -;e i• , :4 *,:4- An�:*4 fi **ic* re i *31c*:i:( ** S:UIE_!! L_L`' ^ ^: >2,000 t'G /KG (RAT) FOR SOLUTION. HARMFUL I F SWALLOWED. CLIP ^ F''` 11 =1 NO DATA AVAILABLE FOR MIXTURE. j!!Ic_ILIa:L_Lj_EL: 'U -)AT:, AVAILABLE FOR MIXTURE. Lijj;J!?!.E_IC_ :If.T KN'Jr,N TO BE CARCINOGENIC BASED ON COMPONENTS. :TR :l, I,S:.(;•::ii rSHA :NO I 'ALL cE ;1UTAGENIC BASED ON COMPONENTS. Ia_j �:II %T j jT :T t I -''.IT.NT. MAY 5E A DELAYED CONTACT SENSITIZER. '" _EIILJ: DEkr1AL CONTACT, INHALATION, EYE CONTACT IP -2008 MATERIAL SAFETY DATA SHEET EMERGENCY NO: 1-(600)-424 -9300 UEEES1 N/A 7 - . 41) FUJI HUNT AND FUJI HUNT PHOTOGRAPHI & - VHEMICALS, INC. WEST 115 CENTURY RD. • P.O. BOX 988 PARAMUS, N.J. 07653-0988 :ATALJG 'J'is :316502 PAGE: 4 OF 6 EELIs_LE_ACUI _LLE2aUE SKIN, EYE, MUCOUS MEMBRANE AND RESPIRATORY IRRITATION. * NUERrJ —MOTOR SYSTEM. PROLONGED INGESTION MAY ALSO PRODUCE TOXIC EFFECTS UPON THE LIVER. :EEEC.Tt: mot= sJE:i IL__SrJSL _3 MAY BE A DELAYED CONTACT SENSITIZER. PROLONGED INGESTION MAY PRODUCE SLIGHT DAMAGE TO CIRCULATING ERYTHROCYTES AND NON—SPECIFIC ADVERSE EFFECTS ON GROWTH AND THE **SEE ABOVE. : at:,:.,:a:., :t,, :,�.,. i• :s' ;:caF ; `•k t:;t,!: ;t a;: , :i::;tq .'s+!: { .s; : -•1: Ycr;:•;: ;est:>`:s!ca;[ic :ia; ter* : tft =fifsh*a;4altsjcs(cfc*:fit: SECTION -7 SPILL OR LEAKAGE PROCEDURE (CONTROL PROCEDURES) •:i: ; i• .t:,,,:t :tt , ,c:, ;c * :'t :y:a a,:•i < it:;:►;:►v ca;r::iv:,.> F ick::; trirt,: a,< s t*: hac*Y ,c*ae*:jt:c ** i,:akitic :: t its !c*+St:Qt****ftati><,csjt AUI2!_EE 3_AI= 3IAL_E_L_ASF_!:3_SEILL.I. :ok SMALL INCIDENTAL SPILLS AND LEAKS, WEAR CHEMICAL SAFETY GOGGLES, AND IEOPRENE GLOVES, AND APRON OR COVERALLS. FOR LARGER SPILLS REQUIRING EMERGENCY ;ESPONSE, NEL? ENE :SOOTS AND RESPIRATORY PROTECTION MAY ALSO BE REQUIRED. FOLLOW ISHA REGULATIONS AND NIOSH RECOMMENDATIONS FOR RESPIRATORY USE (SEE 29 CFR .910.134 AND NIOSH PUB. 37-108) AND EMERGENCY RESPONSE (SEE 29 CFR 1910.120). ISOLATE AREA OF SPILL by DIKING. STOP SOURCE OF LEAK. ADD DRY ABSORBENT. CLEAN JP AND PLACE I N AN APPROVED D.O.T. CONTAINER AND SEAL. WASH ALL CONTAMINATED :LOTHIrG BEFORE REUSE, AND DISCARD CONTAMINATED LEATHER SHOES. ;,;;:f:va;::f:':s ;,::;c:. •, :a at;cit:` ic:(: 4• **+ca4:;c*:ra;titi:ic #s4** < tsts;c:! * s;t•`•s, Sct:�t:�cat�.: }shdt�tsF*** * * r?ts�j *:Qt d: � 3 is o• -r f � � *o s(f SECTION -7A SPILL OR LEAKAGE PROCEDURE (WASTE) :a **ecky.- • *, ::;ci<t:, cry:, cz : : :!ts4res': jcsle:tts;ct:jtX *;..; t:; eft:,y:#sl 4.41*,, :ita;:s;:at***:;c:ttl, : fi,[***sk*:jta;t*sf*t( *: IASIE_DISEJ5AL__1EIEL 'ISPOSE OF CONTAMINATED PRODUCT, EMPTY CONTAINERS AND MATERIALS USED IN CLEANING JP SPILLS OR LEAKS IN A MANNER APPROVED FOR THIS MATERIAL. CONSULT APPROPRIATE :EDERAL, STATE AND LOCAL REGULATORY AGENCIES TO ASCERTAIN PROPER DISPOSAL 'ROCFDURE S. : ,• -c 4. ; :k.:*^', c �ci'at * ,:a cf) * xt tc ;: ;tNt:':•,::F k **2%*iciq :;c ecicY,^ *a;c:(tic►,c*-0c>R[ ts;tsN>'ta;[:It: SECTION -3 SHIPPING DATA is , :a•+ a, . is +:. ;c.;c',:: ;c ... �._ ':7: /:�• ? „• >': :y: :,c a;:>{ a,�:jtff::'t :7.i[�<s�t tdt>c;:a't�.:Yrc ;tic.4�:;j ifY,c:;t :,:s[s ;::4rts} ri`a!::j[a #:h =�ti LI_LL6SS HE "ICALS, 1.9.I. NON—D.O.T. REGULATED. .CI_SI6I_JLJI3 IA_'iL_TY :iIALL::_ X 1115IALL =_ AI: ALAai: LAX_XLIJE.. 11 LLL_IILI_LT..CUL': X IP -2008 SI FUJI HUNT • MATERIAL SAFETY DATA SHEET EMERGENCY NO: 1—(800)- 424 -9300 �• :s•• ,•r ;c ' a• :i• ,;i i ; <::ac?rit:c :roc >r :,tip ka�;• �ci. :FS;ti:T•:[S;clts:a4:clt,;La�ic kx) chi: tYtstt:: F:: �tscf a•< tt:, kt (:iFt�.atit�cs;ta4:�tf�tl;t:►ctf SECTION-9 REACTIVITY DATA :; . °_.' :c.,:,' , �i i .. ..,..,.:c +`, r, ie:c:,:: a<i.:z•f;i. ;a' �.c•;c;�i.:Yt:! s'<d.� o4i. h: a,:, ia: r, a: tti ts,. at�ea. a• sjc: k:l a;: it: ltaeY, :�:t�>its!t:4�t:}:aSC:fcl nEaPEES jLLLILIS, UE53EES EL EEUBEI EAC ^SS HEAT. r r•' �� rjl jIv_ i XIDII PHENOLS, AMINES, STRONG ACIDS AND STRONG BASES. CARBJN 'iliNOXIDE, CAM1LN DIOXIDE, NITROGEN T o gj FUJI HUNT FUJI HUNT PHOTOGRAPHI HEMICALS, INC. NEST 115 CENTURY RD. • P.O. BOX 988 3 ARAMUS, N.J. 07653-0988 MATERIAL SAFETY DATA SHEET i16502 PAGE: 5 OF 6 EMERGENCY NO: 1—(b00)-424-9300 'X LEJES, L'.0 tl :*17.-":1 • SECTION-10 PHYSICAL DATA —...1-..**mvi. •iiIijia-2:21:2I1 '40T APPLICA8LE _ 7 4VITI: APPROX. 1.05 (;1.ATE = 1) yau2_EzE.5.5uEi: APPROX. 15 MM HG (AIR = 1) ZOILIIIL_221.UII> 212 DEG. F. . COMPLETE EILELLIal APPROX. 8.2 APP:,0X. 30!: APPROX. 1 (WATER = 1) 3 OAT4 AVAILABLE „ • •;•: . . !" • , v - ; 'Cr, SECTION.-11 CANADIAN ADDENDUM HYSICAL DATA 300 r.-v,T;Hol 1: NO DATA. EEEEZI1:5_20IdIi <32 DEG. F Ej5iTY: 1.09 /CC : NO DATA AVAIL‘BLE. IRE FXPLOSI1N HAZA;0 1.:-- "P"AIJEE1 NO DATA AVAILA6LE. IEL2L12ILDLIL_=_SEL!5IIIYIIX_ID_2ELnJILAL-IMEALII NONE SEL2.5E:J_IIII_=...iZj5IIIMIII_LLHAIII-DILLULE5L NO DATA. PR!PERTIES Ti Pr;;UULI: . EE SECTISIS i■U. 3 !,ND NU. 6. :E; SU:P;".CT.7.1) rEPORTED AT OCCUPATIONAL EXPOSURE LIMITS. JL:12:11 R-200e =UJI HUNT PHOTOGRAPHI HEMICALS, INC. VEST 115 CENTURY RD. • P.O. BOX 988 'ARAMUS, N.J. 07653-0988 AT ALJG b15502 PAGE: 5 OF . . • . KdNE. k:10: SUP.C:CTED '7:EPORTED AT OCCUPATIONAL EXPOSURE LILITS. :.SUSPECTED , EPORTED.i. ". x: re e: te. - 83! • FUJI HUNT MATERIAL SAFETY DATA SHEET ': NO: 1-(800)-424!"9300" )0 y.,:y********* ..„ ,.•. P — 2008 Product EC Print RA LR Bleach Fix Replenleher 2 X 10 Liters 822366 10 Gallon 822367 EC LR 100 Developer Starter 1 Gallon Concentrate 800048 EC LR 100 Developer Replenishes 5 Oaloti Part A 800045 75 Gallon Part B....: 800046 75 Galion Part C,,. 800047 Sk- V J A Ham- Personal Part Health mability Reactivity Protection Ingredients A 1 0 B 1 0 1 B 3 0 C 3 0 0 0 0 0 0 0 0 0 0 C B C Ammonium <15 Ferric Ammonium EDTA <15 Potassium Me ablaulllte <5 Ammonium Acetate <5 Nitric Acid <5 Water Balance C • Ammonium 7hioauliate Pourlum Moabhat's Ammonium Acetate Water ! °e rne Ammonium EDTA Amino Polywborylk Add Niuic Add Water <45 <10 <10 Balance <30 <5 <5 Balance Ttiethanolamine <10 Potassium Bicarbonate <10 N-NI Diethyl Hydroxylamine <5 Sodium Chloride <5 Potassium Hydroxide <5 Water Balance C Ttiethanolamine <25 N-NI Diethyl Nydroay6m <5 Stitbase Suaanic Add DoinYre <5 Sabena Suronie Add Datvadva <5 Water Balance C Pan.Pbesylaa+dhnrnc Danube <35 Wafer Balance C Potassium Carbonate <5 Triethanolamine <1 N.P t Dktbyt Nyioayla inn <1 Water Balance C) 4 . O m VMIS Information as of April 1995 For additional safety Information consult the Product MSDS sheet. For Medical Emergency Call 800-424-9300 Page: 10 s �"a Amount CAS # 7783.1a8 16731-55-8 63161.8 7732.185 21265.50.9 60004 7697.37.2 7732.185 7783188 21265-50-9 16731-55-8 631.61.8 7697-37-2 7732 -18-5 102.71-6 298 -14-6 3710-84-7 7647-14-5 1310-58-3 7732 -18-5 102.716 3710-84-7 82640-05-9 41098-56-0 7732-185 C Potassium Ca:borate <35 58448.7 Aminopolyphoaphonie Acid, Potassium Salt <10 94021 -268 Potassium Hydroxide <10 131058-3 Aminopolycarboxylie Add, Sodium Sak <5 14001.2 Water Balance 7732-185 584-08-7 102.71.6 3710-84 -7 7732-18-5 Hazards Warnings Skin, eye and mucous membrane irritant. Contact with household or lulus- trial Bleach (Sodium /llpochbrite) can reissue sortie gases. Allergic raoctine to Surma may cause reparatory dimes. Skin, eyes and mucous membrane irritant. Contact with household or industrial Bleach (Sodium lljocbiorite) can mitese tame gass. Sinn, eyes and mucous membrane and respiratory tn tanL Allergic reaction to sulfites may cause respiratory d s- tress. Contact with House bold or Industrial Ble ni:b (sodium Hypocblorite) may release toxic gas Skin eyes and mucous membrane irritant. Chronic ingestion may eaiue Mier and kidney damage, lethargy and weakness. May cause anemia .bod- ing to effect on liver, kidney and flown. Addition of Nitrates to formula. lions containing Trietbanolamine leads to the formation of nitrosanitres which art know to cause cancer. Keep away from all source of ignition. Skin, eyq mucous mtwrbnetw and irritant. h�gestion may cause sno- w and gt sussarsai d us frt. Cbr aare¢aure due b iagaaias nay Mad so kidney and lies damage. May cause anemia leadir ti to eke on kidney; Mar and Munn. Addition cif M Made w formulaliasr cauainirg Tiiabandamine Meads w **formation c fNinaaadne which an known to cause cants. May be • skin swuitiaw. beep away/tom all sources of ignition. 25646.71.3 Corrado, to all tissue contacted. Repeated contact may cause allergic din 7732 - 185 reaction, skin sensitisation or dermatitis. Cbnoeiue go all tissue contactd se . Mucous membrane and ,pinw to au. Skin, eyes, mucous membrane and respiratory Irritant. 1 sedan may cause nausea and gastroitdesttmal dtacompit Cbriesic overexposure due to ingestion may lead to kids and liver damage. May cause anemia leading to efeds on lii3- sw�e! liner and spleen. Additive) of Nitrates to formulations tot tawfetg 7F/dbamdwnaiae leads to the formation ofNtrrosamilvm wtriclb are known to cause cancer. May be a skit sensitizer To Order MSDS sheets or HMIS labels Please call 800 - 526-0851 Ext. 10 . For Chemical Assistance Call 800-528-0851 FUJI HUNT PHOTOGRAPHIC CHEMICALS, INC. NEST 115 CENTURY RD. • P.O. BOX 988 2 ARAMUS, N.J. 07653 -0988 :ATALOG • 'J: 60004.5 PAGE: 1 IJF 6 7)04070.)0 ATT 1: JI'I NEWTON FUJJI Tf-UC'JLDR PHOTO, INC. 13320 E. FIEESTONE BLVD. SANTA FE SPRINGS CA 90670 SECTION -1 IDENTIFICATION •s.:�'t: �::,•.� :.?:• .i;��•.4-,: ;.: �r.�•.Y:':�:t,:i< #:ie,; :t�,:r;::�iexrt:k� is�t�' eke: r�! �4�e�% ��'< i�* �:; e:; tilt �f�* �#: �le�x *�t�k�3t�� *e!'e�F��� *�e�f��= L!r_ A1F_ EC RA L.k DEVELOPER REPLENISHER, PART A PHOTOGRAPHIC DEVELOPER REPLENISHER (TRACE TRAILED AS CT-330-1) L+E:?IS�taL_E_�_�ILY? 'JI,G 4N I C MIXTURE ,UELIICAL_E:anLAI MIXTURE HFYILLL_1Li 1PIILJN_ PALE GF AQUEOUS SOLUTION WITH AMINE ODOR 1,5_1E NOT ASSIGNED — '1IXTURE * *:t.ci` 4., < s, - :ppi. /c,cx: !::cC >c:.ti ;%*mi * * * *4*** * **fit * *A ** ****fit * *3K * *** * * ** SECTION —2 NORMAL HANDLING PROCEDURE ,:rc:;c4•.c: <i .. a:,tA. .c.; ;'•:; c :k ti :, * *1::-;t * *i4 * *n * *gia * * * * *m * * * * * *A * * ** EFLAULEn1.5_ID_5:E_I_ E 11_I - AJL'LLL_ALD_5IIJEASiE: ARr•+FUL IF SWALLOWED. AVOID CONTACT WITH EYES, SKIN OR CLOTHING. UPON CONTACT ITH SKIS. OR EYES, WASH OFF WITH WATER. AVOID BREATHING MIST OR VAPOR. STORE N A CCu, DRY, WELL—VEPNTILATED PLACE. AVOID CONTACT WITH STRONG OXIDIZERS AND CIDS, AND ALKALIES. ADDITION OF NITRATES TO FORMULATIONS CONTAINING RIETHAI;;L:;1I'1E LEADS TO THE FORMATION OF NITROSAMINES wHICH ARE KNOWN TO CAUSE ANCE�. YE_s_ 1 :: '-1ICAL SAFETY GLGGLES (PLUS FACE SHIELD > 10 GALLONS) "., 4F -;AL, ! C'1As!ICAL EXHAUST VENTILATION <ECJNME1DED TO MINIIIIZE EMPLOYEE XP'jSiJiwL. :15 - 1 FLA,tMA;3ILITY: 2 kFACTIVITY: 0 PRJTECTION: C :E: — 1 FLAr'(MA:ALITY: 2 REACTIVITY: 0 SPECIFIC HAZARD: $P -2008 MATERIAL SAFETY DATA SHEET EMERGENCY NO: 1-1800)- 424 -9300 Tr i el l FUJI HUNT INFORMATION PROVIDED BY: FUJI HUNT PHOTO CHEMICALS, INC. PARAMUS, N.J. 07653 -0986 TELEPHONE: 201-967 -9603 DATE ISSUED: APRIL 15, 1994 DATE PRINTED: MAY 19, 1995 REF: FH139 FUJI HUNT PHOTOGRAPHICcHEMICALS, INC. NEST 115 CENTURY RD. • P.O. BOX 988 'ARAMUS, N.J. 07653 -0988 :AT ;LOG Mr): 300045 PAGE: 2 OF o :ASLL_"_'3IEEIAL_ TRIETHANOLAMINE 115_jUA_ 102-71-5 .SbA_EEL_ NON ESTABLISHED Q_EQI S G /KG (ORAL—RAT) LL-5Q1 IQUIE1LAII_L QT_S_ SKIN, EYE, MUCOUS MEMBRANE NGESTIOiN 1AY CAUSE NAUSEA AND GASTROINTESTINAL Y I `1GEST I0 'J '•tAY CAUSE LIVER AND KIDNEY DAMAGE. ASiL_ nI_EIAL: N —N1 DIETHYL HYDROXYLAMINE A5_:a..1 3710 —'14 -7 SUA_EFL? NONE ESTABLISHED ' -2008 LL—U1 NO DATA EEFLEL'Is 20 -25/ LC-5.0.: NO DATA MUCOUS MEMBRANE IRRITATION. ELELE.JI = 1 - 5 % FUJI HUNT MATERIAL SAFETY DATA SHEET EMERGENCY NO: 1— (800) - 424 -9300 •,c►k ;c a;• e�;: Y,,ie:'.,*:;::;c*i::,cY:Sic :{ t****3'c)'c }:icsjci<►,cit*;c ; * Y. c*7C: **?e*►,<**tc***7(t* C**** *** *: SECTION —3 HAZARD INGREDIENTS 7,:i,: ;: :► ::ct.:. :;: -'•: ,:•:t'c►kl:i::::: *c.',.►;c*:;c►;.c:;: ;c4*tc';:; earn' i h*A c►;: x►��C7�.i ;1: ?c**a,:a, 9 /.l c a? c **:{t*•'f***** *'k * * * * ** NO DATA AND RESPIRATORY IRRITATION. DISCOMFORT. CHRONIC OVEREXPOSURE eE_°LE.I_ 1 - 5 % :2_5QI 2190 .1G /KG (ORAL LL`1Qs #SEE BELOW I[L!1ELLgNT F SKIN, EYE AND RESPIRATORY IRRITANT. MAY BE A SKIN ENSITIZEQ. MAY CAUSE ANEMIA LEADING TO EFFECTS ON KIDNEY, LIVER AND SPLEEN. LD50: 1300 '1G /KG (DERMAL—RABBIT); LC50: 3140 PPM -4 HOURS (INHALATION—RAT). PA REPORTING REQUImEMENTS: NONE 9:IL_: "GI= =ILL STIL 3ENE SULFONIC ACID DERIVATIVE As_NLL.: R2640-05-9 iii °ELL 'J0';E ESTABLISHED > 5 G /ECG (ORAL—RAT) I0' SKIN, EYE AND MUCOUS MEMBRANE IRRITATION. �ajr__�_aIEjILs STILBENE SULFONIC ACID DERIVATIVE Ac_ 41096-50-0 iCa_2ZL2 ''r1NE _:3TAHLI SHED !_g2: > 5 ; /KG (9RAL—F AT ) :AILUEIL_JI_EEEELILL SKIM, EYE AND _LI «_ r = 'HATE„ eEELENI? 1 - 5 Y a • .4,, a -Jr a • •■•■,•s• we: • FUJI HUNT PHOTOGRAPHIC cielEMICALS, INC. NEST 115 CENTURY RD. • P.O. BOX 988 'ARAMUS, N.J. 07653-0988 :ATALdG o00045 PAGE: 3 OF 6 ,511A_EELL 4f2NE ESTA6LISHED ESTABLISHED tJONE ESTABLISHED laal-E2LII_'JaILIQD1 143 DEG. F (CLOSED CUP) 1AULAiLE_El21.151YF—LLIIIILI - LOEEI N/A .SVL.S.1.22a1EI:ALIOEI COMBUSTIBLE CLASS III LIQUID 1 FUJI HUNT MATERIAL SAFETY DATA SHEET EMERGENCY NO: 1-(800)-424-9300 7732-13-5 EEELEULL 55-6O 1..C.-11 NONE ESTABLISHED i.-*;!lk*:', SECTION -4 FIRE AND EXPLOSION HAZARD DATA UEEEE1 N/A CHOOSE EXTINGUISHING MEDIA SUITABLE FOR SURROUNDING ATERIAL. ZECIAL_ELia_UIZAEQ-f._Elii-EILLIIIV.5_EELLEDUEE1 WATER SPRAY SHOULD BE USED TO OOL FIRE-EXPOSED CONTAINERS. USE NIOSH/MSHA APPROVED POSITIVE PRESSURE ELF-CrNTAINED bREATHING APPARATUS WHEN'ANY MATERIAL IS INVOLVED IN A FIRE. SECTION-5 HEALTH HAZARD DATA uPayacLa_LLIIIALLuL : NONE ESTABLISHED FOR MIXTURE OR ANY OF ITS COMPONENTS. .YmPrDr. SKIN. EYE, MUCOUS MEMBRANE AND RESPIRATORY RRITATI)N. ANEMIA, LETHARGY, WEAKNESS. MAY BE A SKIN SENSITIZER. tEiLiaticl_Elaax_AID_EaL IMmEDIATELY FLUSH WITH COOL WATER FOR 15 MINUTES. CALL A PHYSICIAN. 'Pa: IMMEDIATELY FLUSH WITH COOL WATER FOR 15 MINUTES. CALL A PHYSICIAN. IlL IN CASE uF INGESTION: DO NOT DRINK WATER. DO NOT INDUCE VOMITING. ALL A PHYSICIAN. lUALAILIN: IMMEDIATELY REMOVE VICTIM TO FRESH AIR. CALL A PHYSICIAN. SECTION-6 TOXICOLOGY (PRODUCT) vt..-;;....T CUT' ' '10T FOR MIXTURE. HARMFUL IF SWALLOWED BASED ON CONSTITUENTS. CUIII_n1. 11 in: NU DATA FUR MIXTURE Na DATA FO k MIXTURE , ■NlwN TO r3E CO:CINOGENIC USHA:NO I"G%Th24T(3): ALL P-2008 FUJI HUNT PHOTOGRAPHI INC. NEST 115 CENTURY RD. • P.O. BOX 988 'ARAMUS, N.J. 07653 -0988 :ATALOG 'lq: :300045 PAGE: 4 OF 6 ! LiIAL'I:.;IL I NOT KNOWN TO BE MUTAGENIC :YE_IIEIIAII2UI IRRITANT • F.13 FUJI HUNT MATERIAL SAFETY DATA SHEET EMERGENCY NO: 1—(800)- 424-9300 ]1SIJJ_IEE1I. Ii[NI IRRITANT !S IULIELL_EJuIES_JE_AaSLaEI1 JL DERMAL CONTACT, INHALATION, EYE CONTACT, NGE ST I ON :EEELIS_JE- ALIVE__ EQUEEI SKIN, EYE, MUCOUS MEMBRANE AND RESPIRATORY :RKITATION. LETHARGY, WEAKNESS. MAY BE A SKIN SENSITIZER. :EEFLI5_1F_LU 2UJIL_sAEt]SSIEEI MAY CAUSE ANEMIA LEADING TO EFFECTS ON KIDNEY, .IVER AND SPLEEN. CHRONIC INGESTION MAY CAUSE LIVER AND KIDNEY DAMAGE. . 0. , 4, ts; ti'es_ ' F ;,ta;'s!: ; a, * * *s',s-ks}*a;e:iie*:ky: des }:a(:s('tcs!c *sjtle*sksrc *de% kit: Ica }tskiethi: ** :ttrt*a;:sksk>;: ! e*f; e!} tsOes4s }es}s►}tritsrt***s6tti[ *: SECTION -7 SPILL OR LEAKAGE PROCEDURE (CONTROL PROCEDURES) .s(:srescs;cs e : • :s ;: s;:r;::tiez<:sk ; c sj:*:(: it i if$ es{: sie sts! cg4slc:[: jtae A; tsj:*: k* sj:* *skd s; c.+, sssF; R; css sk*st, esiCa4s(e sx %,'c * *siC **** ****sits , CIIOU-E JE _L'9Ic4IAL_aELEESL_:]E_SEILLI 'OR SMALL INCIDENTAL SPILLS AND LEAKS, WEAR CHEMICAL SAFETY GOGGLES, AND IEOPRENE GLfVES, AND APRON OR COVERALLS. FOR LARGER SPILLS REQUIRING EMERGENCY .ESPONSE, NEOPRENE BOOTS AND RESPIRATORY PROTECTION MAY ALSO BE REQUIRED. FOLLOW ISHA REGULATIONS AND NIOSH RECOMMENDATIONS.FOR RESPIRATORY USE (SEE 29 CFR .910.134 AND NIOSH PUB. 87 -108) AND EMERGENCY RESPONSE (SEE 29 CFR 1910.120). SOLATE AREA OF SPILL BY DIKING. STOP SOURCE OF LEAK. ADD DRY ABSORBENT. CLEAN IP AND PLACE IN AN APPROVED D.O.T. CONTAINER AND SEAL. WASH ALL CONTAMINATED :LOTHING BEFORE REUSE, AND DISCARD CONTAMINATED LEATHER SHOES. •s( :il* 4: ist r' v c * 0: t< *:; cti::(: *)i***v.tscic*** sky: C*sy: ik>} c>¢:>( ts csfcica; ct ks; C' t*:, kz;•*z{CS(k:tF*=k**i<zt}ctI *** *** *auks• SECTION -7A SPILL OR LEAKAGE PROCEDURE (WASTE) n *1:' ; .t:`.st ec :;:i't c*1!;its; :err :sc:;cre , s c$ ici4s} t ;k>,c*slc>rsk*s}:s(:ic:; *i. *s4** * 4e.t*s 'fdfr;ests}t*•, : ©SIE_LISEIS9L_ iEIitGO: ISPJSE OF CONTAMINATED PRODUCT, EMPTY CONTAINERS AND MATERIALS USED IN LEANING UP SPILLS AND LEAKS IN A MANNER APPROVED FOR THIS MATERIAL. CONSULT PPROPcIATE FEDERAL, STATE, AND LOCAL REGULATORY AGENCIES TO ASCERTAIN PROPER ISPOSAL PROCEDURES. m i v e,,: , , = e :.•'c *. ice :,: s;e:, c x.{ e e14:s yc Fs}:*:',esa :if :jese s4*A41s;edes; 40:1 +,aits,ez; * ;a ' sesk *3.rt�essa}cs�tt�tt�r�ts s}ties(ts( *i. , r , ef � SECTION-6 SHIPPING DATA s <s; s;••;: yir:,cs;:+ � : : ; : %.'cr's !s.� ; : :, :i :c :dss ; -r; tit: tx>,<>' eci::; is ; :i< :'esc ;tsFicirsyc ; :ict; :' its( is�sr :�c�anks ; :s'essf� :s;cs}'st' � ; cs, ts<:' �= fses�c�':>; erf�cst {ts�c:(':s`ts�tspss�cs�t *s(isC QI_LLLi :: ;NEMICALS V.O.I., NON —DOT REGULATED EXEMPT' — SEE 49 CFR 173.150(F)(1). s;•t ,:x,,(, )• 't: '`•• ..AiteA,', ; ;,cs; ip%!:ss;t ci sks!A tAi 4s;t rigs! c is; ric *s'cit*;r:ki •h, s(c*s; *;4ms *sjc *tM SECTION -9 REACTIVITY DATA . ::e .. e, •! . i• , 4: :s,:ir,N es'c:r: : *r *:ks;.s'•.je st sk t :*At •s�srt ;ese �tic i: ies sk sh is �' � $: � :}. i � � � M '•r � # k # # sIc sje of *sir * r A' iLlIY Il Ar.L::: X ! 1 :1'SIAEL`i LII QEQEEEZ LELSIUS 0 LELEELS EAUEEJ EI iP -2008 FUJI HUNT PHOTOGRAPHIC`vHEMICALS, INC. NEST 115 CENTURY RD. • P.O. BOX 988 ARAMUS, N.J. 07653 -0988 - ATALJG 1'•l: 33(1043 PAGE: 5 OF 6 LAY_OLLUE'I riiLL_I,IOI_OLLUE1 X ;OLOjTTN5_TO_AVLl12; EXCESS HEAT, ALL SOUKCES OF IGNITION. ,'JS:.,:.:'L'=IL_'iLZIY. STRONG OXIDIZERS, STRUNG ACIDS, ALKALIS :?L3L= Od LrEL? OL�iLI CARBON OXIDES, NITROGEN OXIDES, SULFUR OXIDES, - .MMJNI A -,. :c: :.tr,::` :s.: •; :; N t* i':4 11:: !i x: Y*1 1.14:**1,,i)tYtl,<s;:***•J, *:!t: t * ****.yt:;e::ie <r!<*,21*s;c%lt *ie **** * ****; SECTION-10 PHYSICAL DATA . ; :s'-., . .... -s;: • :s;::'c �< :;.::;:y! tic ;:' **,.: it:ts'< * *ylt csti*:;is{:latrsf*; * * * *if ** *fit * *• :LIl_Ir _'L1'_'I_ 10T APPLICABLE E_LIF:ij_5c_Y1IYI APPROX. 1.12 (441 = I) . L!'ILI.IY_iN_j is : COMPLETE Eb_E:ALIORI APPROX. 10.3 1.1LIILES_ APPROX. r1Y', I C. L L AT A v AEOE__E:!LSiIY_r DATA (AIR = 1) s e:;; ,:s 3:: i. ;Pr: , _ ides;: ie e.k(*)' :4, at *: q * '*k 1:1* ;cy[* ** *s f * *.e**s4>4st** ** * **** * * *T i:t-s; , %c:,.• c, i�::.•:�:!�. e, * „-..c• ;4,c;,t ;:s'c-,t•! * c t ***J *,,, * *;, ac t c* is s;c F � ��� ski x � �� #�S� #sfsi +ki��� *# # # * *** **#* i SECTION -11 CANADIAN ADDENDUM +: ..:e q ; ,:, c: t s:.s; .:i:<1 <+rs;_ ,:s;e.; : s;::stis': s; *it sc t: }:teir:t*t,'es;:4a:t **:t *.$ * *s!ea'ssf * ** *strfi:** * * *sk * * ** *fie *7 6DJT TigL:i =:L1_ Nu DATA EEC EL `5_EOi>YII <32 DEG.F L'SlIY_ 1.1 G /CC I EE: E: IL IE: I_ :__ NO DATA IRE Tk = XPLCS I'JN HAZAk0 jT Ip :1 r i - ; , !_I_:1E. IAI1_.:_ NO DATA SEL2EI_L'_:LI:: ___SE::1SIIIYIIY_IO_EELEA^_ LAL_111E?ALII NO DATA _ = - NO DATA ?.XIC_LC.GIC. L ”- 'UP_ ;TI S :� I? IL:sIiiJr r: ;' • : L:::;I_ P -2008 Y©EUg_EEESSUEEI APPROX. 15 MM HG EYbE?MAIilIN_SAIE1 1 (WATER = 1) bUILINL_EOINII> 212 DEG.F MATERIAL SAFETY DATA SHEET EMERGENCY NO: 1—(800)- 424 -9300 FUJI HUNT PHOTOGRAPHICHEMICALS, INC. NEST 115 CENTURY RD. • P.O. BOX 988 DARAMUS, N.J. 07653-0988 :ATALOG NO: 800045 PAGE: 6 OF 6 FUJI HUNT MATERIAL SAFETY DATA .SHEET EMERGENCY NO: 1—(800)-424-9300 EE SECTIJNS 3, 5 AND 6. UJT KNOWN JR REPORTED TO BE REPRODUCTIVELY TOXIC. iOT KNOAN 3R - TO BE TERATOGENIC. lAtIE_JE_IQIILJLO5ILALLX-SnEEZISIIL-EELIDULII :nNE KNOWN 'JR REPORTED. ,.....14,9 ,lep..-iplee*,%**:tili!**g.,4cepitei.epeq*****.:4,*****c*******4***YAm**********************, • FUJI HUNT PHOTOGRAPHICEMICALS, INC. WEST 115 CENTURY RD. • P.O. BOX 988 PARAMUS, N.J. 07653 -0988 :ATALJU 'i•;;: 600046 PAGE: 1 OF 5 7(040700 - • A T T'!: JI'" '!Ev4TON r :JJI T?UCCLJI; PHUT9, INC. 13320 E. FIRESTONE 3LVD. :SA(. :TA FE SPF:I'!GS CA 90670 :_LQr NOME-: EC RA Lk DEVELOPER REPLENISHER, PART 6 :iE;✓ILAL__�Ai:':_ PHi1T ^GK APH I C DEVELCPER REPLENISHER (TRADE TRAILED AS CT- 330 -1) .UE_+IEAL_EAmILY_ INLJRGANIC MIXTURE MIXTU ?E NOT ASSIGNED — MIXTURE DIr :LIllt. CrIE.'IICAL SAFETY G0G7,L_S (PLUS L jyEL: '!EJr- ENE • .a P -400. FACE SHIELD MATERIAL SAFETY DATA SHEET EMERGENCY NO: 1-(800)- 424-9300 INFORMATION PROVIDED BY: FUJI HUNT PHOTO CHEMICALS, INC. PARAMUS, N.J. 07653-0988 TELEPHONE: 201 -967 -9603 DATE ISSUED: MARCH 17, 1994 DATE PRINTED: MAY 1', 1995 :a.,; -. ... s'•:rl•, •s<�,:ies :i:x es:ir #- , : ia:,{ c: �[ a;: �. tsatx: ie:;• z4�l: a!t i, ieae�ea, 4a�a�c�er,< �e�e;t a,< s} c�[ rt:;[ a;si'e�ks�e�••sl.ie�eataleM`�e aaea,t�t�}:�t�,k�eakfje�ea SECTION -1 IDENTIFICATION ;t:.. :i•. _:c c,••4a;.>t3.:7 ::a't • ist:?: a:f c2 ac [!cty ;t: :s(tatria!ticskak *414 :at **s **2c%:•',':•4%`ah cat:;:a!t ;eif ***** *** ***: IF > 10 GALLONS) REF: FH140 STZA1,— COLORED AQUEOUS SOLUTION WITH SULFUR DIOXIDE ODOR ,cc :Y < is ,c1i s'r:,c:•.a' l i,*sca::.f 4 x.:: xd': a!: sti a!:. ' **a4a4a(e e s(t ytNesksEcY ***fit * * * ** SECTION —2 NORMAL HANDLING PROCEDURE <• ; - ..•'- , a. 4•,c:cs,aa4 at:' :;e:iO4:¢•atxea':*i *sv ;t a}e *shat*** **yk :,'t e*** pis !:4*it ;e*f[sµl t***** _r:_::E_IAtE _I_;_I1AjDLI_L_AbILLI13Aar_ A!QMFUL IF ;WALL1iED. AV CONTACT WITH EYES, SKIN OR CLOTHING. UPON CONTACT ITH S<I'a OP EYES, WASH OFF dITH dATErR. AVOID BREATHING MIST OR VAPOR. STORE IN COOL, C %Y, .1ELL—VENTILATED PLACE. AVOID CONTACT WITH STRONG OXIDIZERS, ACIDS ND 4LK" "_LI3. TuE :CAL, " "C` +AiICAL XHAUST VENTILATION RECOMMENDED TO MINIMIZE EMPLOYEE EXPOSURE J '•!I£T 4'10 'JA ?1: i. :I: — 1= •1LTri: 3 F.LAAtILITY: 0 REACTIVITY: 0 PROTECTION: C °A — I =ACTH: 3 FL.At 0 REACTIVITY: 0 SPECIFIC HALARD: CORR i . *: i:: ; <ic:;:a sio:t,e : :a;:aer!:es i� :'.irde t +; .' a:;t± tr:Y,::l::ttra:uis,. :F ;'[yrgrst :;t a; ,Fs�s :1: kdi:r ;t aksKak>te14$:: :UJI HUNT PHOTOGRAPHIC CHEMICALS, INC. JEST 115 CENTURY RD. • P.O. BOX 988 ARAMUS, N.J. 07653 -0988 ATALCG NO: 500046 PAGE: 2 OF 5 SECTION —3 HAZARD INGREDIENTS :�:i' :�; 7':) ,:).: : [.`,:i• +�•]: ;:ic )::i,: :E: :h t'! . Y,. c: t". t: l�ai��l t.` tt; ta t: r:' r:'! t;!) ia; t: �t ;<a;tati:�c:tti::'s Bill,: T, ft': �tx •::�:1;t A.aiL__E:IELLLL: PAR.— °HE` :YLENEDIAMINE DERIVATIVE A5_ 25645 -71-3 SUA_2EL: NONE ESTABLISHED Q_qQ: 'SEE BELL "W LL_EQ;, NO DATA IalIElcala_=EEELIii SKIN, EYE AND MUCOUS MEMBRANE IRRITANT. ALLERGIC ENSITIZATI N TO SKIN, CAUSES DERMATITIS. 200 -400 MG /KG (ORAL_?AT ) ,JATER AS—JD...: 7732-13 -5 eEgC.JI_ BALANCE Sb9_E =L: Nf)NE ESTABLISHED Q_EQ: NONE ESTABLISHED IltIEIAUI_PEEELI: NONE ESTABLISHED .;f4 *Air ti i:,"r <•!-*a;ticux=q:, +. �;tst * *:c:r*:;ca'tit*:}r cat ;cic:,4.;ts+:jcy:* ;a<:k*S;c#:*at**:,: >, c�c:k ye t*:t c*aY:(cf::}** taic**is*i SECTION —4 FIRE AND EXPLOSION HAZARD DATA _ ,.tic trti:s; t ti ::'c:, : ;ts:f ::; :,ca;.:;4 *ktdcit:;;a' ca xn:, ti$e-* Aeco.: 0..*:, cad•'**It :paycalc :;tajt;;rfs!c*K,**4 4* t:!ca}c*** k*yJtyt*a( * _95y_PPijI_LEILPP: NOT FLAMMABLE _9 n rL__ - L N/A �L+S_�LSS�IEij3II:1�: ' -2008 NOT REGULATED FUJI HUNT MATERIAL SAFETY DATA SHEET EMERGENCY NO: 1—(300)- 424 -9300 EEPL_yI_ 30 -35g LL"_EQ.L NONE ESTABLISHED UEEFE: N/A CHOOSE EXTINGUISHING MEDIA SUITABLE FOR SURROUNDING \TRIALS. _ EL. IAL_ EiEE_ J: ZL' L'_L_EI'_L_ElaII115_ESLLLDLE__ WATER SPRAY SHOULD 3E USED TO JUL F Ii' E EXPOSED CONTAINERS AND /OR TO DISPERSE VAFi7RS. USE NI OSH /MSHA APPROVED JSITIVE ?v.c»UkE SELF — CONTAINED BREATHING APPARATUS WHEN ANY MATERIAL IS I\ IN A FIRE. cart •t : ta` a'. s e e �' c: c:: s' :h:'• : :;eat:;a;:s'::i Bea' cltak :(:iai* *3:cs;:a+:;ea * eA* ksav; ; eaks; e',CAa;ea0e*****EX4*) SECTION-5 HEALTH HAZARD DATA :: r, :,. :t' • , tti' , r� �t:; c: l::; c>,<: M/, tzcsta' c:k ca;•s; c: kar�; cs:! r :�::bra;c:c�rac�;cq:a;t:fact`c; Ica: ac: fci�ta' cia�c> t': ti: a�C�cyrs!tc(cak>tta�Cat�}t�1c *Y .1L'EJL _L!.:il_Y:LLE: NONE ESTABLISHED FOP MIXTURE OR INDIVIDUAL INGREDIENTS. jV ?zIPOS : CORROSIVE TO ALL TISSUES CONTACTED. r _ .I:;. Im"EDI1T;=LY FLUSH WITH COOL WATER FOR 15 MINUTES. CALL A PHYSICIAN. 1 • FUJI HUNT PHOTOGRAPHICCHEMICALS, INC. NEST 115 CENTURY RD. • P.O. BOX 988 ARAMUS, N.J. 07653 -0988 '.ATAL'1G j00045 PAGE: 3 OF 5 :YEc_ " I :DIAT_LY FLUSH WITH COOL WATER FOR 15 MINUTES. CALL A PHYSICIAN. - N1E,,SIj_'_ INS CASE OF INGESTION, IMMEDIATELY DRINK LARGE QUANTITIES OF WATER TO :IL)JTF. INDUCE V'OMITI'NG. DISCONTINUE IF NAUSEATED OR UNCONSCIOUS. CALL A HYSICIA' :. :11HLLLII1 I'1'IEDIATELY REMOVE VICTI:4 TO FRESH AIR, CALL A PHYSICIAN. :T :!. t :1 -�;' ;`i" , : r •.,::�:;. :�. L: i': ,S :p :��. �::�:',: is T!a:f �,f :' ::j: �s'n;;�'cirsti>;ci,:s;:Y: >!c of �<i,: •�c y <sr �t de sic st:; ast s!aa:4it:{t.',t>�,4ttY,:><t s�C Sfe ac tik �t7�t yt:afek!:sk �}t. SECTION -6 TOXICOLOGY (PRODUCT) •,, :;ci •.•<i s:. .: • .... ;e: errs': 1. .11c:;C : :**.sus}'ties(r;ti.*:y *Atti :fit :4a'j • k*>;serF* roc. ids( 01:c4,4**iR*** ***sktRs( *: £UI" ?&L LU—SH: 1273 MG /KG, (RAT). HARMFUL IF SWALLOWED. LUIE_:E=' "3L_LO_:12? NO DATA FOR MIXTURE CUI :_.j:I:1L_L.__1_ NO DATA FOR MIXTURE AELjICi:__tIL: NOT KNOWN TO 3E CARCINOGENIC NTP: :10 I.ARC :N7 OSHA :NO INGREDIENT(S): :'ALL UItALKALN_ NOT KNOWN TO 3EE MUTAGENIC YF_l�'�llJllia:ls CO 'ROS IVE % HUNT MATERIAL SAFETY DATA SHEET EMERGENCY NO: 1-(800)-424-9300 Kl�_jc3lI Ili_! CORROSIVE EIUCLEAL_ HUIES_L DERMAL CONTACT, INHALATION, EYE CONTACT, NGEST IUN. EEEUS_JE_ICJIE-raEQSUEEi CORROSIVE TO ALL TISSUES CONTACTED. EEELIS_ :E_Ld REPEATED CONTACT MAY CAUSE ALLERGIC SKIN REACTION, KIN SENSITIZATION, ANU /Or UER.!1ITITIS. ._ ... ;:,, , *: :: * :'c,ci:a;::;r* : ::{:*r!:ys4.*** Y h * */( -3t c:tisic*,A4f • K:*4!***Iicv*** **sr'yr*i; SECTION -7 SPILL OR LEAKAGE PROCEDURE (CONTROL PROCEDURES) ; -c;::'c ,•*,t :;ca<*,,:Y.:4 ;ss; ::<:Fs;sits( *te*itah:le, eta; cak:( t: tt :t *:fraticscififa}c r c:k #ie*S4*sjc* Ili: E_ I_LAIEZIAL_E_LEaSE__^Ji_52'_LLi )R SMALL I :CI DE`f FAL SPILLS AND LEAKS, WEAR CHEMICAL SAFETY GOGGLES, AND OPF.7NF GLOVES, AP"D APRON OR COVERALLS. FOR LARGER SPILLS REQUIRING EMERGENCY _SFOvS:, NE'JP .ENE MOOTS AND RESPIRATORY PROTECTION MAY ALSO BE REQUIRED. FOLLOW SHA •EGIJLATUJNS AND NIOSH RECOMMENDATIONS FOR RESPIRATORY USE (SEE 29 CFR ''10.134 A •IIuSH POB. G7 -1(m) AND EMERGENCY RESPONSE (SEE 29 CFR 1910.120). SPLATF M,?EA OF SPILL 6Y DIKING. STOP SOURCE OF LEAK. ADD DRY ABSORBENT. CLEAN ANO ?LACE I:1 AN APPOVED D.J.T. ' CONTAINER AND SEAL. WASH ALL CONTAMINATED REUSE, AND DISCARD CONTAMINATED LEATHER SHOES. :s,: ; •: s . •:,. i•..•- ,;•: 4• • *•4 t :'caF: csc,'e:;: *s;:stc ; c, e, 4it •.4acie*::: ,4*ataxa; :>.::;c: tai:!..; sses! r: k*a; c:;. sc: ts: Fslci hs SECTION °7A SPILL OR LEAKAGE PROCEDURE (WASTE) • . . . •..: ; :; 1. s ,: ;s -;: s s,: a s,: i : a ?: * > : * * 0;: s;c a i tt * a!• * s(:* sk sk ,.: i st 0, sic tic fps a}c 1y: as * * ak: * sit ; a -2OO8 • FUJI HUNT PHOTOGRAPHIC'CHEMICALS, INC. VEST 115 CENTURY RD. • P.O. BOX 988 'ARAMUS, N.J. 07653 -0988 •ATALOG `C?: /3u0046 PAGE: 4 OF 5 EEcIE1sjAY1IY_ APPROX. 1.13 ( 4ATER = 1) lYSICAL SAT; •-2008 S 1 FUJI HUNT MATERIAL SAFETY DATA SHEET EMERGENCY NO: 1— (300)- 424 -9300 13POS= :')F CONTAMINATED PRODUCT, EMPTY CONTAINERS AND MATERIALS USED IN CLEANING 'P SFILLS OR LEAKS IN A ►•BANNER APPROVED FOR THIS MATERIAL. CONSULT APPROPRIATE EDE•ZAL, STATE AND LOCAL REGULATORY AGENCIES TO ASCERTAIN PROPER DISPOSAL ROC _DUi;.'ES. *;,,, (ciet• '': ;: : i •;: s = ; c:,e:4::ci ::.'ei,:* ie: r: t o 'e:;c;k#iry:s;::i:*a “22: 0ei;:::**n! Lt:;:,'„ e*Sk*ifs{::; eat*:}t`jt:hs *** *** t ***: SECTION-3 SHIPPING DATA •s - * • v . 3,r:.ei:zt::ress 04,i,:4*10:s;ea:*> *Al..,;e:jt**24c4:s iLa :: Ir* **usyesks{rdk**21.t►jes►s`e *s4t4::xsK** .GI_LLL.SS� C'.RR!7SIVE LIQUID, N.O.S. (CONT.AINS PARA— PHENYLErJE DIAMINE DERIVATIVE),UN1760 1rJT APPLICABLE e, : , e.i ::c.c • : :s: : t,.. rr!::!:: Y: 4 sc: a 4:s c:c :'fc* * kale; tsj:;• sk:{ esje{::' t ;:.;eutta)'>;e:' cat: lcat:, e*{ rits5ta4i,<; 4rt:(: sif*sft *****sQe*sp•#*:,. SECTION -9 REACTIVITY DATA i :* ): ' •t• :: * ta *r!,:;.at* t..4 , t t. y . 1 1 ,�, ,, :,' 1 .:,.:f:.: >!c ;e.,. stiolt�, :eieo;t ;es'::1cs�e:;t:!C>ks�CS;< .�Y ; e ;e*,t>~t ;L+y:s9t***ris' she # {::yt*>besks{f*{e * IZEILiIY SIA,:.L__ X LUMALLEI AI. DUEEEi LELSI!!S. DEaBEES EABEElib.1 AL6:?I21211S_EOLYJE3ILAI.LLUI CAY_OLLIUE1 4I ILL_LJOI_OLCU3_ X DJDIII2N5_I2_9Y2I:21 EXCESS HEAT yCLIMEt i 1LIIY_ STRUNG OXIDIZING AGENTS, ALKALIS, ACIDS utaloui_DELT.2 5IIIIN_?EJDDL : AMMONIA, AMINES, CARBON DIOXIDE, CARBON ONOX I DE. 4 *1- ,:s :i,:iti: .ic:;e '•:e it., :roof °,e:�c:; *:* * ,:!c * ** r:; ::;r r d *** .� s :its; <cF �f�';'i <+�'�'1' %f#:� �•{����ti- :+icoi:s�t� r'7��i '� #:4th!{ :,ss!e *� *��`�sF fs{:�k { SECTION •10 PHYSICAL DATA i s, ::: } s,: • ;to' +::•': < *:'o;:e' h :>:•s 'c •a;t**i: t >;ca! e e 021.* e:ky ** * ` z i *:yt:,�e** ',L h• � �� �• •,- �,••Y• /'Z 3 � �•I' � f��•Jrt A �� �� i4�r� �R 7: tY �,,�7d: iTk.< f',L* LLII _?_iLiI_ NOT 4P?LICAaLE LOILIL&_EOiJI_APPROXI`1ATELY 212 F YAEO3_EEESSUEE1 APPROX. 15 MM HG LLJ'= iLiIY_iu_ SAIL_? COMPLETE ED_F_SLIQE_ APPROX. 1.13 =LA11L 2. APP -.0 X IMATELY 70% EYAKSAIj1y_EAIC_ APPROX. 1 (WATER = 1) E? _LE�SIIY?':OT APPLICA3LE (AIm = 1) • .. ... i :: : ;:: \: t- t : , : , acs t;e.::oe xe: c:.: t>`. ;.s,:i :4'':*st'tiitsJere4ex ►; is, t:,: 21r s41 1 et A>;t; e: k: 1 , i,tt r:::,:: tis4i5: 1 C4esk:F:yt*14Cs(•:44C* • >ittA:* ,t:.. . . . <•ri , .c:. c,t - ;:i• ; .h. uts +,•:: • :c t ., etieit:;t s . i s { :� : e ►� Jr s, c ,t s ,� 21c ,L alc s4 ie >!c s;< Y.: ;: y 4�'h 4.'e * * {C s►r* ok ►,. she ie SECTION -11 CANADIAN ADDENDUM ;.,ic e:'tot*s k s• ; <�ko;c�: i c o;c:,t*v *: loci: i:. is' s> f :* **S(t*:cf*s {c**212144: :UJI HUNT PHOTOGRAPHIC VEST 115 CENTURY RD.. P.O. BOX 988 ARAMUS. N.J. 07653-0988 ATALT", .)00045 •PAGE: SoLEJk OleXIDE T 4c : DATA E2FrIIN5-EQINI: < 0 DEG I:11;s .I; 1.13 S/CC IT . NO DATA HAZARD.: 1 10=1.r , JIIIrq_PAILRE: NOT APPLICAlat LeL25.1...:11_111,1_=_LZ.IISIIIIIIIX-II..!IEUALIILLL-ILEACII NO. DATA LI - ND DATA iXIC2LCGICAL Pv:;PE 0 -2008 • EE SECTiONS 3, 5 AND . aLV::.01).LCIIYE_EaLLIIX1. CT WIC 'eon 'EPORTED 7 •21ILT -, %1CiTY: CT KI1O4N JF 2NE KNCW4 REPTRTED Y , INC. 5 OF 5 FUJI HUNT MATERIAL SAFETY DATA SHEET EMERGENCY NO: 1-(800)-424-9300 FUJI HUNT PHOTOGRAPHICtHEMICALS, INC. WEST 115 CENTURY RD. • P.O. BOX 988 PARAMUS, N.J. 07653 -0988 :ATAL;JG ?00047 PAGE: 1 OF 6 70'i4C700 • .TT' : JI;1 NEWTON FUJI T='UCOLJR PHOTO, INC. 13320 E. FI!<ESTONE LVD. SANTA FE SPRINGS CA 90670 ..,. t•,.. r;: .... s .. r .,. Y..r. <a;. .., :rY: s, ::,c a. )r aF sl: a;::F:;: a;: t!•. s :?: ��::;::;c a;c t'•:t r; ;Y >;:' - �aYs�:;c: ::k :,s a,: �: >c:,c it a;c a;•:!r :sti ;t s(c i <���c �r 1f * ars!:• SECTION -1 IDENTIFICATION .ac :i•. . ; .• Y i. :r :, ... r,: :a ;u;::;ca :trlck a , `�r :, eY:: ka;<>(: a!: srl es{ cic: t> 4. ca� !e�':sse �ea�:;;:ftt:si:aesk ; isfcae*;•*:t**,jC;•*s! °**at: =C RA LR DEVELOPEk REPLENISHER, PART C AlE>rLEAL__!IL�.: PHOTOGR :APHIC DEVELOPER REPLENISHEk (TPAJE TRAILED AS CT-33C -1) REF: FH141 1FLiICEL_El?t:1LY_ INORGANIC MIXTURE :115.1!1ELL_E2SU L@_ "IXTURE :"E:ULAL_UELE2IGII211 CLEAR, PALE YELLOW AQUEOUS SOLUTION 'WITH CHARACTERISTIC 1DOR :@s_^;2, NOT A SS I GAED — MIXTURE :s . :;c,, %* vi O. <ic:t:tc:i:a; *v :;r:; * ci r•fski<q:t;e : k*xe;: a s" ca,. s} e,;::< *: e : ac eieyc;' assFs( :**#A*;tsf*)k***sjc* SECTION —2 NORMAL HANDLING PROCEDURE ::4 :,¢);.s,• �• _ , :ixrits t)' a;::.t e*:yt -.is* :*ti::;<: **,^icse: **IgA lea' a *ac':4it*vg* ;e4sf>j.at ; :a; * a' :~: FEjL! II::_ IS_ I.].. L_ I3E>= _�_I�_ "1:IQLI�J2_EtiE_SIEIh9S�E_ .AP;MFUL IF SWALLOWED. AVOID CONTACT WITH SKIiN, EYES, AND CLOTHING. UPON CONTACT •ITH SKI`I '1R EYES, FLUSH WITH LIBERAL AMOUNTS OF WATER. AVOID BREATHING MIST OR AP!JRS. 'iADLF IN AREAS WITH 4DOUATE VENTILATION. STORE IN A COOL, DRY, WELL '7.NT ILATFJ PLACE. AVOID CONTACTING +MATERIAL WITH STRONG ACIDS. HAVE AN EMERGENCY YEAASr! :,Ni) SHQ'JE,.0 AVA ILAGLE. Y..:_ CHc • C.AL SAFETY GOGGLES (PLUS JP.IENE GLUVES ILiE.: qt. : :P:t_ Ic AP;I'ON SE ! c L .CAL 4 ECNANICAL EXHAUST ? T'J ) 1INIMIZE EMPLOYEE EXPOSURE (FUME r.A CUST, ETC.) _CIS — FLAMA '1ILITY: 0 REACTIVITY: 0 PROTECTION: C Frt. - ,I=A,LT I: 3 FLAwiA?ILITY: 3 REACTIVITY: 0 SPECIFIC HAZARD: CDR 4P -2008 FACE ) a FUJI HUNT MATERIAL SAFETY DATA SHEET EMERGENCY NO: 1 -9300 INFOMATION PROVIDED 3Y: FUJI HUNT PHOTO CHEMICALS, INC. PA N.J. 07653 -0988 TELEPHONE: 201-967-9603 DATE ISSUED: APRIL 15, 1994 DATE PRINTED: MAY 19, 1995 SHIELD IF > 10 GALLONS) +. �:.,,: ;.s: ' +! ).t,., +);. ,.�,ay :' +r• .:)ts: bras:, ; s'ca;• s :> �:a,:s,:r, i:i, s. :k :;c:;csia} FUJI HUNT PHOTOGRAPHIC 'CHEMICALS, INC. VEST 115 CENTURY RD. • P.O. BOX 988 'ARAMUS, N.J. 07653.0988 AT.:L:?ti 100047 PAGE: 2 OF b SECTION -3 HAZARD INGREDIENTS :. .. i >:. :�ca•: c'! il: ;t• t .,t ' :;c ,?,. ;•*# * ti* 4► .'c ;,4I;JJPULYPHCSPHONIC ACID, POTASSIUM SALT n _ _��_J••• J4021-26-'3 cut, C'°! • 'I!.)NE ESTAtiLISHED 1_21: 'J DATA LL ....5.0. NO DATA CUR='CSIVE TO EYES. SKIN AND MUCOUS MEMBRANE IRRITATION. ESi _::n1::_j_L: AMI"W)POLYCARBOXYLIC ACID, SODIUM SALT 141')-01-2 EE &ENLL 1 '•W' ESTABLISHED 1_ 4: . :SEE LL_5D_ NONE ESTABLISHED iQ jEI!;,' IT 'PE`LI.F: SKIM, EYE, AND MUCOUS MEMBRANE IRRITATION. LD50: 4640 • •IG /KG (ORAL-MOUSE) PA REPORTING ' NONE 9LIE:_2LI =31AL_ POTASSIUM HYDROXIDE 1 1310-5o -3 EEELEJII 5-10% ' "!3 (CEILING) 365 16/;G (UR.L, AT) LL_22: NONE ESTABLISHED ja:IE1Lt\I_ c = =EIs: CI'RRL'SIVE TO ALL TISSUES CONTACTED. SEPA SEP:'-ZTI �'Ec;UIFEMENTS: SU3JECT TO NOTIFICATION AND REPORTING REQUIREMENTS J SARtA TITLE III SEC. 304 (40 CFR 302 - CERCLA HAZ. SUBS. LISTS, RQ = 1,000 !S.), SEC. 311 AND SEC. 312. A5IL_m^I1:L _ PWASSIUm CARBONATE ;HL_ EST .' ShED 1 'r'I TATI:.''i. ',,/..$i (c LE—t12: NONE ESTABLISHED SEVE:;.E SKIN, EYE, MUCOUS MEMBRANE, AND RESPIRATORY 4 ...F T1'!(:; , .,.:!1I;■cEYE.NTS: ;ONE P -2008 MATERIAL SAFETY DATA SHEET EMERGENCY N0: 1- (300)-424 -9300 EE2LEJI2 5 -10% CE EEI? 30-35% r9 FUJI HUNT FUJI HUNT PHOTOGRAPHIC CHEMICALS, INC. WEST 115 CENTURY RD. • P.O. BOX 988 PARAMUS, N.J. 07653-0988 CATALt?G. `L.: :4CtyO47 PAGE: 3 OF 6 EMERGENCY 'V0: 1-0800) -424 -9300 :AL - =' - -j -� -- II.1TEP 7732-1-5 _SY! "- __L:LI NONE ESTABLISHED '`I iNE EST.ADL I SHED =1 Q:uEIQj_T_LEEELIs_ NONE ESTABLISHED IPA EPO TP.G REWIREL1E:NTS: ;TONE LL__ NONE ESTABLISHED :d - :'' >;' <: :ui: :];<:t >': :]': t • t :'t :►! st:,];c►,t •':it • ** * * * ** * . :,t , :;t � :F x a'<-. :;c �.: � : � ., �: t: r ^c q. ];t ];e �t �: ;�: ];s !t ►,t ►'e :;c 'e c 't ]tt •t e * t ►i: 4►, 'F3 � SECTION -4 FIRE AND EXPLOSION HAZARD DATA :. ..... , . .. ,: 7c; r. ti: rt. cw***.4:':** 2, c: xr•.:; t: ;c :,.i <xsj:t'cia *'! :.+; ]. it .'• *c 'cit**►;t *):a* * ** i * {a _L 4.5E_2i1j:1I_JEIt1:1:)i NOT FLAMMABLE 1L31?nELE_ :IELEIYE_LLLII51 - L1 k1ES? N/A E1i2_LES:LELC,AIL2.1 . NOT REGULATED (NUN—IGNITA.BLE) NoN—COMBUSTI ?LE. CHOOSE EXTINGUISHING +MEDIA SU'ITA+3LE FOR 3URkOUNDIAG MATEkIALS. aEELIAL_ EIS _ d4 z2EL _L_FLEE_Ejaa1_ta_ESCL:DIEF_ WATER SPRAY SHOULD BE UTILIZED TO :OOL FI=E— EXP•.JSED CONTAINERS AND TO DISPERSE CAPTIVE VAPORS. PERSONNEL SHOULD :HPLOY POSITIVE PRESSURE SELF — CONTAINED BREATHING APPARATUS WHEN ANY MATERIAL iAS IGNITED LIR IS INVOLVED IN A FIRE. TRY TO REMOVE MATERIAL CONTAINERS FROM = I R E AREA I F I T C4'1 BE ACCOMPLISHED WITHOUT RISK TO PERSONNEL. , 1 f , :' s> tt;: **Jri �►,: i,•:!• it► Ic►; e*i; e ►:] F:' t ;. 01.e: kirirc ►ti>;;:fe4t44►k *tK*#*tea!e]!t. SECTION -5 HEALTH HAZARD DATA :►.. :'::, ...�: ?+ •/• „ ,: 'ci• : `•: ,:i r, ci; <!!o;:it►t Sc :;et;tJ•4;t+;t>t► ">; tit {:u tir:: f :*S;t:h+{t►ti*>;t**);:dt: :dE'EIILQL:i_LL UI_YALNE_ NONE ESTABLISHED FOR CEILING) (ACGIH 199U -1) :y_aIIS_E_JY= __E1205,LEL_ CORROSIVE TO ALL ' .ACT, A ND . +UCc)US ;1EMBRANE IRRITANT. `+AY BE ? CL_E1,E ICCIATELY FLUSH WITH COUL WATER FUR AT LEAST 15 MINUTES. CALL A HY51CI::'t. yFE_: Iii :•IirtI.ATELY ILUSr; WITH COOL WATER FUR AT LEAST 15 MINUTES. CALL A HYSICI.'+. 1'1. EDIATELY ()RINK LARGE QUANTITIES OF WATER. DISCONTINUE IF NAUSEATED UNC:2NC1'.u';• tJO NOT INDUCE , IO;IITING. CALL A PHYSICIAN. ::!."''VF VICTIM TO FRESH AI. IF BREATHIN'.G IS LABORED, GIVE OXYGEN. ALL 1 iP -2008 71 .1 FUJI HUNT MATERIAL SAFETY DATA SHEET EEELENI? BALANCE U2EEE.L N/A MIXTURE; POTASSIUM HYDROXIDE 2 MG /M3 TISSUES CONTACTED, RESPIRATORY HARMFUL IF SWALLOWED. o:. • .., �•'4,;�>,• • !< ::, c:t..,.� s:,a>• .:t ►, i�:• '.f,•,:;'ti +c;tt,.►s!c:, ica�t%tdr:.l:: }:lc•;: ;•i; �c7tt'►;i►c t]ys;�titt!ca�t �'tifi FUJI HUNT PHOTOGRAPHICc;HEMICALS, INC. NEST 115 CENTURY RD. • P.O. BOX 988 'ARAMUS, N.J. 07653-0988 .:00047 PAGE: 4 OF 6 I':7LIE':IC: NOT •KNOwN TO BE CARGINOGENIC IARC:NG OSHA::10 PIG 'CALL NOT KNHWN TO BE MUTAGENIC • CUR S I VE 4P-2008 7 FUJI HUNT MATERIAL SAFETY DATA SHEET EMERGENCY NO: 1-(800)-424-9300 SECTION-6 TOXICOLOGY (Pk(JDUCT) .CUI: _ NU DATA. MAY 3E HARMFUL IF INGESTED BASED ON COMPONENTS. NO DATA FUR MIXTURE +.0 DATA FOR MIXTURE 1,121 coqkcsIVE iIJLIEaL_:;:TiIi.S_JE...111.5a2IILJi DERMAL AND EYE CONTACT, INHALATION, INGESTION. lEit:T.5..i:=_ CORROSIVE TO ALL TISSUES CONTACTED. MUCOUS MEMBRANE, kin - TRACT IRRITANT. IFEUd..2L-L12&QUIL-ZAECilFal NONE KNOWN OR REPORTED EXCEPT THUSE SECONDARY TO • ISSUE DA,IAGE. S . SECTUDN-7 SPILL Ok LEAKAGE PROCEDURE (CONTROL PROCEDURES) , :=!* , . , : , ' , Ar , ***1"..etv*At:xqm , $v0;:lk*********0:********************m****Nt***i . t.alIE21111._EELEASE-2;2_LEILLi PR SMALL INCIDENTAL SPILLS AND LEAKS, WEAR CHEMICAL SAFETY GOGGLES, AND ECIPFNc: SLLVES, AND AP!:ON OR COVERALLS. FOR LARGER SPILLS REQUIRING EMERGENCY ESP qEOPRENE iOCTS AND RESPIRATORY PROTECTION MAY ALSO BE REQUIRED. FOLLOW SHA .FFGULATIJNS ANO NICSH RECOMMENDATIONS FOR RESPIRATORY USE (SEE 29 CFR q1(J.134 AND NI'f:SH PUB. -37-105) AND EMERGENCY RESPONSE (SEE 29 CFR 1910.120). :)0LATB A.?,EA OF SPILL BY DIKING. STOP SOUkCE OF LEAK. ADD DRY ABSORBENT. CLEAN P AND PLC F IN AN APPROVED D.O.T. CONTAINER AND SEAL. WASH ALL CONTAMINATED LC REUSE, AND DISCARD CONTAMINATED LEATHER SHOES. .. -- -- ••••,. • • • ; •••••:. ••••• SECTION-7A SPILL OR LEAKAGE PRUCEDURE (WASTE) • •;,•; : ; ••••: ;••• - . I I :11!17,• „: j. V 7:C*PV: 1. 1.:TX).11::Ce.0 411;1/4 SF 11 FEDEAL, STATE AND Lt3CAL PROCEDURES TO DISPOSE CF CONTAmItIIATED .!:10 C1F C:NTAINERS. CLEAN MATERIALS 4NO IMPLEMENTS USED IN RESPONSE CMULT L.CAL FFDERAL, STATE, AND LOCAL REPRESENTATIVES FOk ASSITANCE Alf) CLAN—UP PROCEDURES. -.44-5 4 5. .• . •': • %. 3:4 s.• NZ 1 it IV • i:%,C);‘***11. 7.t 104****,:ti.c il * ******Yt* SECTION —F SHIPPING DATA • FUJI HUNT PHOTOGRAPHIC'CHEMICALS, INC. WEST 115 CENTURY RD. • P.O. BOX 988 PARAMUS, N.J. 07653-0988 :ATAL5G 'J!2: ti00047 PAGE: 5 OF 6 • :a:sc .. •; i:•: ;: a ,ca ;c•r'..c: :., :t: >: a; • ' • !: :Ci:c ltd is c:i:cis cake t: k i:gt:F acs'ra f , tit•R > r::s,f. : 9,ret a *f 41* t*. �liI_LL�S�_ :N i3SIv: Lr':JIG, P.J.S. (*:SEE BELOW) UN1760 : POTASSIUM CARBONATE, POTASSIUM HYDROXIDE) ± :ac '::.: :r.. ; > %:tic c :a;: ? s sta ;;s: :sr i.at i ti<:f:a: a;:ic •a'ta' +t::.•"..c s:'.; tit ak � � X � : � �•• � % � is i• � k '}c i� i = # tit *:(p:yc:,t ie ae,?t is SECTIGN-9 KEACTIVITY DATA ?• ,:ai -r :t is : i t::'r,; ;c :;cat:;.•, c c:,: a�at:'_ ;::';,, + cak ,4:s **iFac **ai*i: i< sjcaFf ,.s;;*s¢:{t>1c*r}c:ltlh sc I9 ILiIY SIdZL:.� X U:15IALLL1 dI_ _dY_ELLUE_ Ir EXCESS HEAT LULUjL' AIi:L1LiIY_ ST?JNG ACIDS PK'lnuLI: CARBON OXIDES, )HOSPHINE. ca•a: i:44t.e, s: a • e ,, ,vatshs'caje><:a;:aiac **,a:z s41:; e Yc **4:;t*r±:>ic>kajc *** **4 SECTION -10 PHYSICAL DATA e• * 4 ,. ra• :w:>;: >, a< e:'e�ei< �a!e a'< ei,:i: . tiuti * r v �1 3• i X %Y icy.,{ > Y*ica; s$ c F *> t>; ta; c: 4a;: r: ak., c>:; c***>!rsE*>R*!•****# iELII�L_?Qi JI_ `�:J DATA PELiEIL_jZnY1IY? .PP;OX. (WAT_r = I) iEiL!.+�iILiI"_I.L_w?I:.`'3 COMPLETE 1. 'HYS I CLL :).;T 1 AP-2008 LUILIyQ_EO1.II_ >212 F MATERIAL SAFETY DATA SHEET EiiERGENCY NO: 1—(t300)- 424 -9300 QUEEES LEL5I11S o Jr ILL_QL'I_QLLUE. X 71.7. FUJI HUNT PHOSPHORIC OXIDES, AND 1.50 YAE02_ESESS!l8E1 APPROX. 15 MM HG E_FALIQR_ >14 l MESS EdbEESIJE !OL= IILZ :3 AP' :dE +'" nF';31IY_NO DATA = 1) :a:.. •a! , :a• .J .4. t1; is Jr a :. j J. ie9•:t•l <aea;.•ks: :s• r> >ea;.a'•s'r:�;ti :,:: �r�s�. a' c: FaFl :,�cat:jrs�+k;.;,k>;•a4testtfr , t..;:: ks,t> ,tst>Qe**scjt:ye**r`.se. 5O FYde_ _EAIE: APPROX SANE AS WATER ( =1) ;c a;. ,•;: a:. • ac :i ; :•: + - , v.t�cstq t! rr.ki :ar.,c$ca : ,*:a a�ra .:Fa,t >; :c:, :i• :: . i,:scr:s�:;caar.xi:; :: ' :�. g at ,. , ;< t:,ckk:!rs'c% ;c>lkrti�yc: SECTION -11 CANADIAN ADDENUU:1 �' .. •) ,'• j,:1, ::A-r; ev ,• ' tit;r ?':,e:;rrr:'r:�.aeit:,: �ita4a: .1 a Pt t' ieY: .ae:a% a�: r •k R i :. ti: � �' �::ti a'r x• a': a;.•�,c °t s(c sc:{c >.; �s>Y:,4:f sh. ajt: L6. + +::' C�••1;,aCT�: ►.I_T1C 4J DATA E3E.`.Z.U5_2LL1JI: <32 F L.i 1. :)n 6/ ��P` TL1:: �I .E DATA • FUJI HUNT PHOTOGRAPHIC CHEMICALS, INC. NEST 115 CENTURY RD. • P.O. BOX 988 PARAMUS, N.J. 07653-0988 EXPLOSION ,HAZARD . .JOXICOL.IGICAL PROPERTIES . " • • .ONE 7,EPORTED. .EEE:JDULILYZ_I;LAILIIX1 ONE KNOWN OR sEPORTED : • - IONE KNOWN OR.REPOPTED• laJE nF TOAIL2LULMILLX_SXUEELUSIILEEpUCII ONE KNO,JN OR REPORTED 1P-2008 1.1ILIti11:4.11:RLIE:12LELIUiEl NO DATA NONE KNOWN ONE KNOWN MATERIAL SAFETY DATA SHEET ATAL6G tJ0047 PAGE: 6 OF 6 EMERGENCY NO: 1-(300)-424-9300 414 **Y;******4 4 vst-*********************************** . ****44k • FUJI HUNT PHOTOGRAPHIC CHEMICALS, INC. VEST 115 CENTURY RD. • P.O. BOX 988 'ARAMUS, N.J. 07653-0988 'TAL,1i; NO: 319234 PAGE: 1 OF 5 P -2006 7004.1700 . T T : JP! P! N EW T O N FUJI TRUCOLOR PHOTO, INC. 13320 E. FIESTDNE BLVD. SANTA FE SP:<I!lGS CA 90670 ACETIC ACID SOLUTION (2.5 GAL) •LFUIs:91._4 ACETIC ACID SOLUTION, 9O4 E'L'IELIiYE_L_>UI2_JELII YE:: CHE'•IIC::L SAFETY GOGGLES AND FACE SHIELD ^IITMITE OR PVC REF: H0541 MOO 3 ' ' FUJI HUNT MATERIAL SAFETY DATA SHEET EMERGENCY NO: 1 INFORMATION PROVIDED BY: FUJI HUNT PHOTO CHEMICALS, INC. PARAMUS, N.J. 07653 -0988 TELEPHONE: 201-967-9603 DATE ISSUED: MAY 5, 1995 DATE PRINTED: MAY 19, 1995 •-' .. ..:: < .ei:... :r':• •k :':r:;:;:�. >i:._._ ,:cii:'er'•'•:;t >,e> ?:a, c ': :k:tii �c:is a!ea!e -c,,: i trt: seataete Ye:t>;: 7!t•tdlt t ay. SECTION—I IDENTIFICATION r as:, :i +,c ... 9. ts' -;: ;t ;:.::,::;t +, a;' ' :a;. >:ie:;e:ci ;c� r:aea:e ;.a} a:t:�a>r.arstiat.4ie ;< ; iea�: ieua} r�cae�e;<:! til •sje>4¢e�:afa4>!ts(eskst5n�tlf * �k �f .17EJ1LAL_EaLILY_ ORGANIC ACID :l:.= +t1LLL_LO=U1.11 CH3CCOH /H20 AJEULLL_LIE CLEAR, COLORLESS, AQUEOUS LIQUID WITH STRONG VINEGAR —LIKE 1DOR .AS_Jui_ 54-19-7 i :> :i: :s }. a;:se:! *::4fa;:a'c** rt::F 1e*At:c 4::;eacats4a;c>;:r;e*s4 ta;:**;.%**a;;>:Y a;:**a4>; c>;c:kaYe:Qt*a}t**ayctlM***: SECTION —2 NORMAL HANDLING PROCEDURE ., %. ** : .:.c: cr' ; m e:A *i: ,::It ;;T>,: ** ,:>; :a;::tca'::c : :c:;ta'c4sc* * ts!:ic.r *i, a s. * : lut ak a;calt s, . EC :JIi :1_x_1:1 2 = Il_JAJLLI L- AJIl_Sltr.'EALEI ARMFUL IF 3waLLUW_D. AVOID CONTACT WITH EYES, SKIN OR CLOTHING. UPON CONTACT ITH SKI.J!j4 EYES, WASH OFF WITH WATER. AVOID BREATHING MIST OR VAPOR. STORE IN COOL, D Y, JELL —VENTILATED PLACE AWAY FROM ALL SOURCES OF IGNITION IN A WELL ENTIL ATF.0 PLACE AEDVE 62 OEG. F. AVOID CONTACT WITH STRONG OXIDIZERS. Iii::.._ vc3P Jc AP-.ON AND SOOTS OC;L ►:CH txiiAtl:iT VENTILATION REC0;MJ•+ENDFD TO '1 "'ii) V PL %S. - FL 2 REACTIVITY: u PKOTECTICN: 0 J=i.'a - H= 5 FLiMMAIIILITY: 2 REACTIVITY: 0 SPECIFIC HAZARD: COR MINIMIZE EMPLOYEE EXPOSURE , :. : ''3 t>,: t icy :.:, taj:: � c: 'n;•:ir:c:;ci'r•kr•:::(<ic,ra> altvh c>Jt.��r; <�'r ' RECEIV�D CITY OF TUKWILA - r�.�K,l. ( l 1 19;1 "l PERMIT CENTER `UJI HUNT PHOTOGRAPHIC CHEMICALS, INC. VEST 115 CENTURY RD. • P.O. BOX 988 'ARAMUS, N.J. 07653 -0988 AT.1L 3G.1 'lei: 31')234 PAGE: 2 OF 5 .ASi._ I L L' ACETIC ACID ',4 -1) -7 10 'Pm AlE_:.'al:ElAL_ 1,ATER 7732— 12'—i :5.tJA_EEL? 'TONE ESTABLISHED NO DATA AVAIL :ILLIEILLII_EEEELI5.s NONE ESTABLISHED LtSli jI_? :I�_�i_ 1Cb F TCC (AST! 056) COM3USTIBLE LIQUID • ' FUJI HUNT MATERIAL SAFETY DATA SHEET EMERGENCY NO: 1—(800)- 424 -9300 SECTION —3 HAZARD INGREDIENTS �:.. .s . ;d ... ..'s:' , :,'. e:'s: ;• :•',' ��::'ai<:F: s::k r :'.n' i,::!:i•�:;:r' n;<o;cs,c �:�tat�.r;<�:�:r'sr;er ;cr;ea4r� u.i =rte x;t: eEELENI_ 90 -100% •2_!i1: 3.3 G /KG (ORAL -KAT) LL-5Q1 5620 PPM /1 HR (MOUSE) :lL_LlL E=YS t SKI'', EYE AND MUCOUS MEMBRANE IRRITATION. CONCENTRATED GLUT INNS `SAY CAUSc BURNS. SEP& RE'CATI 4G E•.1UI REMENTS: SUBJECT TO NOTIFICATION AND REPORTING REQUIREMENTS F TITLC III SEC. 30L, (40 CFF. 302 — CERCLA HAZ. SUBS. LIST, RQ = 5,000 HS.), SEC. 311 AND SEC. 312. EEELEy BALANCE. LL_.Q: NU DATA AVAILABLE **i.:':. *:- :'!: <��::i +:r ::c= cr4 :k rk:,:s,:*,i: *:ka;c.;t**::; rye :h *20!( t:; es':*ojc: li** i.c**:(r'lt*i: ;tA:;tst• *r` *** *Y SECTION —4 FIRE AND EXPLOSION HAZARD DATA mi.: *,: :�.. ....,. ...>!•:;t ,,t c —4, * *• N,-;42 ;:: t ics,• •r:•;:ti:sl **:4.2 i *:r! *iF*fie**** **4****4 *rt ** * **t LLN" N/A 1fi . N/A WATER SPRAY, DRY CHEMICAL, ALCOHOL FOAM OR CARBON DIOXIDE. ?::LI_'L_EI__ LA_:J_L_ElEE_Elatal iE_EZUELIEEI wATER SPRAY SHOULD BE USED TO COL "XP2SED CONTAINERS AND/OR TO DISPERSE UNISNITED VAPORS. USE NIOSH /MSHA PrH WED P';SITIVE 2 ESSURE SELF — CONTAINED BREATHING APPARATUS WHEN ANY MATERIAL S I14V;JLV'=0 I:t A FIRE. •• ; ;..,• °�' b� >.•R � �' . 'K a :; crk: f'! tt�c�e >SCrk�e�t�t�c:4�t�cit�Ca�>f: SECTION—.3 HEALTH HAZARD DATA .• . :; qr s �,.::c.;c,i�•s, ::,`.:c, ; r;:sc:;.:,c:,: C:':s!:a' >,t�c:c:ta'cr,t; : k:}:> k k;:.::; c�fi:: k�4rt :4r}t�.sFr': *:!t�k * #�kicrc *�k _ _v�Ltt� : ACETIC ACID 10 PPM (TWA), 1`.� PPM (STEL) (ACGIH 1991-92) 1 "►'I�� •'� 1 V' "�L_'�i1�E, Ct1RROS IVE TO ALL TISSUES CONTACTED. MUCOUS MEMBRANE %I) r• I T •' Y 1 I T AN T. , : r:, P -2008 u ot•Mn. r. FUJI HUNT PHOTOGRAPHIC CHEMICALS, INC. VEST 115 CENTURY RD. • P.O. BOX 988 'ARAMUS, N.J. 07653.0988 ATALOG NU: 61g234 PAGE: 3 OF 5 EMERGENCY NO: 1(600)-424 -9300 I,'1M,EDI \TE.LY FLUSH WITH COOL WATER FOR 15 MINUTES, CALL A PHYSICIAN. • YLi_ Ii•MMEDIATELY FLUSH WITH COOL WATER FOR 15 MINUTES, CALL A PHYSICIAN. I :! CASE OF INGESTION; IMMEDIATELY DRINK LARGE QUANTITIES OF WATER. 'ISC:)NTINUE IF NAUSEATED OR UNCONSCIOUS. DO NOT INDUCE VOMITING. CALL A HYSICIAN. .'IUALAIIjN: IAmEDIATELY REMOVE VICTIM TO FRESH AIR. CALL A PHYSICIAN. x: "cs ;� :z; :,c:c:; ! :i.. +. -:i 1 t :cici<x�:ic:frricris;: >: :a,assc�'ta'ca' k:�e taac�:akarac�c:Yacic ,4icic>kaer 4�: sjt�< atc�c�: a;: {:a�s��Caics�csjt *>Qcaktals�:lt SECTION -6 TOXICOLOGY (PRODUCT) c:;:.'s<:Y:, .:c•..•� roc =e: •;•••;e *• ,: s::.'>;:: tce:.: s':..: 9q:.:;': s :err:,ea'::$s;cz;.a ;ca;•a <z;e ;: ats'eat •ic :hae•+!t �a'•�e �aia!e <ie a4 .I;IJI__Jz :AL_L2_1 3.3 G /KG ( HARMFUL IF SWALLOWED. .LUIL_1..3ULL_L.1.nI 1060 AG /KG (RABBIT) LUI;;_INdAL_L L_5�: 5620 PPM /1 HOUR (MOUSE) 1 LI "ILS=_JIL: ']OT K4JWN TO BE CARCINOGENIC NTP:,1( IARC =Gi OSHA :NO I:1GREDIENT(S) : .BALL :UILL =:'ILI NUT CONSIDERED MUTAGE :+IC Yr_IEEIIAIiL'�_ COFKOSIVE FUJI HUNT MATERIAL SAFETY DATA SHEET cI_�_I3J3IIAII_'3I CU) kOSIVEE DERMAL, INHALATION FE= L'TS_ 1E_ �L ?1I_.:��'L�S�:� CCRRCS IVE TC ALL TISSUES CONTACTED. MUCOUS MEMBRANE N'!) F S'rI"ATE] :2Y I lh'IT ELELIq lg f'-1 = ' , IL_= �2u5LI4:EI NONE EXPECTED EXCEPT THESE SECONOAhY TO BURNS. ii':...... ?: +ri i< .: i.• ;r•c.:':*:tr ;i si *i'ea ss;ci:s' 4e ;c:;as:t** cats;:std.A*.*:4*,P;t4c*:(tva vie% a; r*xk>; tac**NCSk*>ft****:;eaY**, SECTION -7 SPILL OR LEAKAGE PROCEDURE (CONTROL PROCEDURES) i : :s,: ,•s' is ..: . :x.Y:ac a'• a: : s; ;ea' : >is a; :; tae: y :s;• s;• .yt sf. *a ; iakata a:e411`je*iFa!C*:'tsk ;t**s;. :te a!t c:ltai LII1 =1; Pn AID : ::_UE_SEILLI OR. SMALL I;NCIDENT•AL SPILLS AND LEAKS, WEAP CHEMICAL SAFETY GOGGLES, AND =OPRENE GLOVES,• AND APRON OR COVERALLS. FOR LARGER SPILLS REQUIRING EMERGENCY ESri'.•NSE, 'DOTS AND RESPIRATORY PROTECTION HAY ALSO i3E REQUIRED. FOLLOW SPA kEGUL, \TI°.1NS AND NIOSH RECOMMENO4TIONS FOR RESPIRATORY USE (SEE 29 CFR 910.134 ANO •:I LSH PUS. E7-108) AND EMERGENCY RESPONSE (SEE 29 CFR 1910.120). SULT!: F SPILL 3Y DIKING. STOP SOURCE OF LEAK. ADD DRY ABSORBENT. CLEAN a •till) PLACE N. AI APPF'OVED D.O.T. CONTAINER AND SEAL. WASH ALL CONTAMINATED Lr?THI`!C ;.ELISE, AND DISCARD CONTAMINATED LEATHER SHOES. a s 't a' •y •,ci:? :�:a;r k:e:c:as,:s' s,ei:a;ci:.�:�cr!• r:; s:cxefi •trxrr:;caty:a�s': <a'es.c'ea'c c y: it t��ie>; eistty!to!tx}crea�eatiea;t>�e {c SECTION-7A SPILL OR LEAKAGE PROCEDURE (WASTE) •r a. ..i• .s •� ..: ::ti• ital.a7i<x.it:h:. :it >:•t.;. ' sir- s• atr.• dci.41:4- caca4ajcrc.,,<s':at*4 tea::es; ::014: 4:aks)t:lkat*ek* .<+w,a',.,n;surw..xrc. �.us�arv.} rrtr. a• ux.,,...,..,.....«..............., _. ............._.._. «.......... FUJI HUNT PHOTOGRAPHIC CHEMICALS, INC. (._ NEST 115 CENTURY RD. • P.O. BOX 988 'ARAMUS, N.J. 07653-0988 .ATAL'T)6 '43: b19234 PAGE: 4 OF 5 EMERGENCY NO: 1- (300)-424 -9300 ?ISp( "SE )F CONTAnINATED PRODUCT, EHPTY CONTAINERS AND MATERIALS USED IN CLEANING IP SPILLS '.it? LFAr:S I'+ A MANNER APPROVED FOR THIS MATERIAL. CONSULT APPROPRIATE 'EDERAL, STATE AND LOCAL .REGULATORY AGENCIES TO ASCERTAIN PROPER DISPOSAL ;ROCEDUkE_. :r:.•) • ^.'t:, : . ;4:< *a;:a'ti,:71,:4' :a;t •�t_ca!: *. , ta ; t * *4k * * *** ** �. j;$- a;a�tst :a;:4;_w4sci,tic4;t4h4' tt>;:ar 4� SECTION -5 SHIPPING DATA • : : :; 4,:;,c :;;=:4; :.3ii ;c ;e4`::4:;a:;e Y.t • (**=:tV244,Xes;ea **11:.4,* beef: k>:: aj: ths!:>, 1c*:4n1t*;es:sk►cs #sjt**' ,CETIC ACID S3LUTII:N, 3, UN 2739, PG III :CI_SI_I_::■E!I_ HOT APPLICABLE t �ti i.s c.a;.x'.'J.: ^'••::.'rt:t• ::.: a :rty: ;c :'e s'tr: ,t s;: !: a,: . 4;. �rY,: i:; tYt',:s t:; t�! ei� s{: ;tfp:rics4�`•4jc+�:4F >;esear a�C Yt:;es�+.�t:;is�':IesQeafs�t s{t s�t:�t:�t sQt 4h 4�t 4�t; SECTION -9 REACTIVITY DATA Y; :`•'; t , + , 4 •' : *e-at *. L i;.t'•4eirit4l A :;c*V4):1;tYcelitrt:+ ,X :'S** isk*sjcgts? eYta;;: 4Yc*;t sks'<* k;A:; t*i **3 1I91:iLIIY SIIsL =? X UNSI9 =LEI All DESEEES LEI-11111p i9Z9 :! ^t> ; tl3Y_JLLUE1 HILL_NDI_LLL1lEI X :CNUAILUti1:_IJ_AYJI?I EXCESS HEAT, SOURCES OF IGNITION AND FREEZING TEMPERATURES. :N=I2AII:iiLIIY_ ST OXIDIZERS, ALKALIS, NITRIC ACID, CHROMIC ACID, •EROXIDES. :9Z4E:h :US_QDL _°_L'SIII::L_ i.:LULCIl CARBON MONOXIDE, CARBON DIOXIDE .a4.,e..st . •!:4• , 4;::;ta, :y:*Af*a}c:ks;c ,:;. t4; eA4t4eis:, t: t>' eYe 4i **YrY:Y.;eYt•}eiRst*a}t:{ **i ** * * *:Qts}**,, SECTIOON-10 PHYSICAL DATA :'t :. i:....... �:::x':�.;4 +: :, t: e4k :cs,:F:;'t:•Y;at:,c:..:c:�x'r�c tr�:�:4!:ac t�tscYiYcitsts{ 4Eo!t:j:sc:. fi•Yt * * *rti * * * *�'s>4x : =LIL' !�_�'�I 19 OEG F' :2ECiEIL_L'LLY1IY_ 1.06 YAEUiLEEESSUSE3 11 MM HG 20 DEG C (dATC. = 1) : LLLt:IiLIIY_Il ti T: cI CCMPLETE appPr'.0X. 130% (+I :' = 1) IP -2008 MATERIAL SAFETY DATA SHEET 5:5iLitlii_EU.UI1212 -222 DEG F EJ_EACILGI <1.5 FUJI HUNT REHEES EA JEENU: EY9'usaiCL'_sAIEL APPROX. 0.97 (NBUAC =1) mi :±:;er, :xci a :0t4; i,•s:.d.i'r•Yc.;k;:sta`e:ft: eta;• Y�: eati< a:As ye> Sca4a; e*ses!: tt:,i4'f*s{calt*Yt>tt*4 :t0s! * .. • ... A: 4'1 :a .::.ti y:; ^ .s:� e: �u': i. d.a! jerk: Y : ; ::i :aat4c* ;1 :t Ms! ta! t:!: i ti, ::,.g1Ys*44Y,cs4a;tYtxs>ksjt SECTIJN -11 CANADIAN ADDENDUM i :t s.: :ti,::.s::cs;.ie: t•4•:'.>tds,af.i.:4:ra :e >c>:oc�::Ms�itafk:.eaYco <a'e:ye is�: >'ta; : ya; ys tFx4�e s�e:;e:<t�{[skycits�Ct�>;ex's DIJ_ISaiIII2N_ILa 9IUJE ? NO DATA SEL2SICU_ E: IIi___S ELSIIIYlIY _IL_'"ELb9JICAL_I►UEACIi NONE LELJ I2r ;SAT ; NO DATA OXIC'iLr1GICAL PROPERTIES FUJI HUNT PHOTOGRAPHIC CHEMICALS, INC. VEST 115 CENTURY RD. • P.O. BOX 988 'ARAMUS, N.J. 07653 -0988 'ATALUG `1'l: 819234 PAGE: HYSICAL DAT. Dal ST:.CNG VINEGAR La_I_ S!JL'L2: NO DATA L;�S1IY_ 1.06 G %CC ZaE.ILIL_I_1F_JAIEELLIL_E'I IEIBUl Lil NO DATA IRE OR EXPLOSION HAZARD • LUSII1ZAIIJiLID_PEDQUCIi OT C:1NSIDESED A' SENSITIZER • EP3DLJCIlYE_IDUCIIY_. ONE KNOWN, SUSPECTED CR REPORTED AIOEE•JILIIYi • ONE KNOWN, SUSPECTED UR REPORTED EBELZlEDIJI_ � �E_ 1!=_ I'.' �1:: JLJSi1L3LLY _SYJ_ES15I1C_EELII!!CI_ ONE KNGr:'1, SUSPECTED OR REPORTED iP -2000 MATERIAL SAFETY DATA SHEET 5 OF 5 EMERGENCY N0: 1- 1800)- 424 -9300 m., :s , e- .:<>.es,: ;c:. :{ 4- ,:' * :rstt;ci��c:;cs;•sts;r�c ;ci,::j:: ;: si* .4icieslcsk:!cs°0;ta::tsts4:4 cs'ts;:ies;: i�t�c�e#: c!::{.sksf*'Y>;c** * **si****' iewr . Fu t "TRUCOLO NC 110 4'O'3 ?ARK eAsts. oToKwudA wAstAiN&ToN 181 A. kZ.I- PoKVAI. pi-kowm ve(eNitkektoweERII.v=. lot $teerkotkiA%< - 501Te toS TAcookfic wA51-11N&Tos etemoz. C-0N1tNT4 ME22ANINE cAL. — PvAG omit, — t RECEIVED CITY OF TUKWILA JUL 2 5 199 PERMIT CENTER _ Multi- Loaded Beamf AISC 9th Ed ASD 1 Ver. V4020965 By: A. HELGE DORDAUBERNHOFT , PHOENIX DESIGN on: 07 -24 -1997 Project: FUJI - Location: BEAM # 1 Summary: A36 S8x18.4 x 12.67 FT Section Adequate By: 55.7% Controlling Factor: Moment of Inertia Deflections: Dead Load: Live Load: Total Load: End Reactions(Left Side): Live Load: Dead Load: Total Load: End Reactions(Right Side): Live Load: Dead Load: Total Load: Bearing Length Read.(Left) : Bearing Length Reqd.(Right): Bearing for P1: Bearing for P3: Beam Data: Span: Maximum Unbraced Span: Live Load Deflect. Criteria: Total Load Deflect. Criteria: Uniform Load: Live Load: Dead Load: Beam Self Weight: Total Load: Concentrated Load P1: Live Load: Dead Load: Total Load: Location: Concentrated Load P3: Live Load: Dead Load: Total Load: Location: Properties for:A36 S8x18.4 Yield Stress: Depth: Web Thickness: Flange Width: Flange Thickness: Distance to Web Toe of Fillet: Moment of Inertia About X -X Axis: Section Modulus About X -X Axis (Calculated): Radius of Gyration of Compression Flange + 1/3 of Web: Design Properties per AISC Steel Construction Manual: Flange Buckling Ratio: Allowable Flange Buckling Ratio: Web Buckling Ratio: Allowable Web Buckling Ratio: Controlling Unbraced Length: Limiting Unbraced Length for Fb= .66`Fy: Allowable Bending Stress: 1EXFr;E`1 / 18942 1 7 - z4 -/997 DLD= 0.04 IN LLD= 0.27 IN = U560 TLD= 0.31 IN = U494 RL1= 5325 LB RD1= 677 LB RT1= 6003 LB RL2= 5010 LB RD2= 669 LB RT2= 5679 LB BL1= 1.00 IN BL2= 1.00 IN BL P1= 1.00 IN BL P3= 1.00 IN L= 12.67 FT Lu= 0.0 FT U 360 U 240 wL= 500 PLF wD= 80 PLF BSW= 18 PLF wT= 598 PLF PL1= 2000 LB PD1= 50 LB PT1= 2050 LB X1= 2.0 FT PL3= 2000 LB PD3= 50 LB PT3= 2050 LB X3= 9.67 FT Fv= 36 KSI d= 8.00 N tw= 0.27 N bf= 4.00 N tf= 0.43 N k= 1.00 N lxx= 57.6 N4 Sxx= 14.4 N3 rt= 1.05 N FBR= 4.70 AFBR= 10.83 WBR= 29.52 AWBR= 106.67 Lb= 0.0 FT Lc= 4.223 FT Fb= 23.76 KSI Page: 2 Multi-Loaded Beam( AISC 9th Ed ASD 1 By A. HELGE DORDAUBEFtNHOFT , PHOENIX Project: FUJI - Location: BEAM # 1 Web Width to Thickness Ratio: Limiting Width to Thickness Ratio for Fv=.4*Fy: Allowable Shear Stress: Design Requirements Comparison: Nominal Moment Strength: Controlling Moment 6.606 FT From Left Support, Nominal Shear Strength: Maximum Shear: Moment of Inertia: :.• •. • • . • vee. v4020465 _ DESIGN on: 07-24-1997 hitw= , 22.1 AVVSL= 63.3 Fv= 14.4 KSI Mn= 28512 FT Mu = 17154 FT-LB Vn= 31219 LB • 6003 LB 37 IN4 58 .IN4 Multi-Loaded Beam( AISC 9th Ed ASD I Ver. V4020965 By A HELL MRDAUBERNHOFT , PHOENIX DES( ■.4 on 07-24-1997 Sex18.4 / S Shapes / Steel Beam"-' Project: FUJI - Location: BEAM # 1 L= 12.67 Ft ,•:.RL1=:5325 rico =: 677 LB RT1= 6003:LB. PL1= 2000 Lb PD1= 50 Lb 2:0 Ft. wL = 500 PLF wD - 60 PLF , • . PL3= 2000 I.B • PD3= 50 LB @ 9.67.Ft. , • . Multi- Loaded Beamf AISC 9th Ed ASD 1 Ver. V4020965 By: A. HELGE DORDAUBERNHOFT , PHOENIX DESIGN on: 07 -24 -1997 Project: FUJI - Location: BEAM # 2 Summary: A36 S8x18.4 x 12.67 FT Section Adequate By: 52.8% Controlling Factor: Moment of Inertia Deflections: Dead Load: DLD= 0.02 IN Live Load: LLD= 0.28 IN = U550 Total Load: TLD= 0.29 IN = L/520 End Reactions(Left Side): Live Load: RL1= 5799 LB Dead Load: RD1= 309 LB Total Load: RT1= 6108 LB End Reactions(Right Side): Live Load: RL2= 4536 LB Dead Load: RD2= 277 LB Total Load: RT2= 4814 LB Bearing Length Regd.(Left) : BL1= 1.00 IN Bearing Length Reqd.(Right): BL2= 1.00 IN Bearing for P1: BL P1= 1.00 IN Bearing for P3: BL_P3= 1.00 IN Beam Data: Span: L= 12.67 FT Maximum Unbraced Span: Lu= 0.0 FT Live Load Deflect. Criteria: U 360 Total Load Deflect. Criteria: U 240 Uniform Load: Live Load: wL= 500 PLF Dead Load: wD= 20 PLF Beam Self Weight: BSW= 18 PLF Total Load: wT= 538 PLF Concentrated Load P1: Live Load: PL1= 2000 LB Dead Load: PD1= 50 LB Total Load: PT1= 2050 LB Location: X1= 1.0 FT Concentrated Load P3: Live Load: PL3= 2000 LB Dead Load: PD3= 50 LB Total Load: PT3= 2050 LB Location: X3= 7.67 FT Properties for:A36 S8x18.4 Yield Stress: Fy= 36 • KSI Depth: d= 8.00 N Web Thickness: tw= 0.27 N Flange Width: bf= 4.00 N Flange Thickness: tf= 0.43 N Distance to Web Toe of Fillet: k= 1.00 N Moment of Inertia About X -X Axis: Ixx= 57.6 N4 Section Modulus About X -X Axis (Calculated): Sxx= 14.4 N3 Radius of Gyration of Compression Flange + 1/3 of Web: rt= 1.05 N Design Properties per AISC Steel Construction Manual: Flange Buckling Ratio: FBR= 4.70 Allowable Flange Buckling Ratio: AFBR= 10.83 Web Buckling Ratio: WBR= 29.52 Allowable Web Buckling Ratio: AWBR= 106.67 Controlling Unbraced Length: Lb= 0.0 FT Limiting Unbraced Length for Fb= .66 *Fy: Lc= 4.223 FT Allowable Bending Stress: Fb= 23.76 KSI Page: 2 Multi-Loaded Beam( AISC 9th Ed ASD 1 By A. HELGE DORDALJBERNHOFT , PHOENIX Project FUJI - Location: BEAM # 2 Web Width to Thickness Ratio: Limiting Width to Thickness Ratio for Fv=.4*Fy: Allowable Shear Stress: Design Requirements Comparison: Nominal Moment Strength: Controlling Moment: 7.537 FT From Left Support. Nominal Shear Strength: Maximum Shear: Moment of Inertia: ' .•• • • • Ver. V4020965 DESIGN on: 07-24-1997 h/tw= s 22.1 AWSL= 63.3 Fv= 14.4 KSI Mn= 28512 FT-LB Mu 17343 FT-LB Vn 31219 LB V= 6108. LB Ireq= 38 IN4 I= 58 IN4 RL1r= 5799 LB RD1= 309 LB. RT1= 6108 LB PL1= 2000 Lb PD1= 50 Lb @ 1.0 Ft. Multi beam[ Ai n co mow V■41JZAJOL.J.., By A. HEI-GEr? RDAL/BERNHOFT , PHOENIX DESIcm, on 07-24-1997 S8X18.4 / S Shapes / Steel Beam Project : FUJI - Location: BEAM * 2 • wL = 500 PLF wD = 20 PLF • 67 Ft PL3= 2000 LB PD3-= 50 LB @ 7.67 Ft. RL2= 4536 LB RD2= 277 LB RT2= 4814 LB .. ;.:.. Xi- Multi-Loaded Beam( AISC 9th Ed ASD 1 Ver. V4020965 By: A. HELGE DORDAL/BERNHOFT , PHOENIX DESIGN on: 07 -24 -1997 Project: FUJI - Location: BEAM # 3 Summary: A36 S8x18.4 x 12.67 FT Section Adequate By: 117.5% Controlling Factor: Moment of Inertia Deflections: Dead Load: DLD= 0.03 IN Live Load: LLD= 0.19 IN = L/783 Total Load: TLD= 0.23 IN = L/664 End Reactions(Left Side): Live Load: RL1= 5010 LB Dead Load: RD1= 669 LB Total Load: RT1= 5679 LB End Reactions(Right Side): Live Load: RL2= 3325 LB Dead Load: RD2= 627 LB Total Load: RT2= 3953 LB Bearing Length Regd.(Left) : BL1= 1.00 IN Bearing Length Reqd.(Right): BL2= 1.00 IN Bearing for P1: BL_P1= 1.00 IN Beam Data: Span: L= 12.67 FT Maximum Unbraced Span: Lu= 0.0 FT Live Load Deflect. Criteria: L/ 360 Total Load Deflect. Criteria: L/ 240 Uniform Load: Live Load: wL= 500 PLF Dead Load: wD= 80 PLF Beam Self Weight: BSW= 18 PLF Total Load: wT= 598 PLF Concentrated Load P1: Live Load: PL1= 2000 LB Dead Load: PD1= 50 LB Total Load: PT1= 2050 LB Location: X1= 1.0 FT Properties for:A36 S8x18.4 Yield Stress: Fv= 36 KSI Depth: d= 8.00 N Web Thickness: tw= 0.27 N Flange Width: bf= 4.00 N Flange Thickness: tf= 0.43 N Distance to Web Toe of Fillet: k= 1.00 N Moment of Inertia About X -X Axis: Ixx= 57.6 N4 Section Modulus About X -X Axis (Calculated): Sxx= 14.4 N3 Radius of Gyration of Compression Flange + 1/3 of Web: rt= 1.05 N Design Properties per AISC Steel Construction Manual: Flange Buckling Ratio: FBR= 4.70 Allowable Flange Buckling Ratio: AFBR= 10.83 Web Buckling Ratio: WBR= 29.52 Allowable Web Buckling Ratio: AWBR= 106.67 Controlling Unbraced Length: Lb= 0.0 FT Limiting Unbraced Length for Fb= .66 *Fy: Lc= 4.223 FT Allowable Bending Stress: Fb= 23.76 KSI Web Width to Thickness Ratio: h /tw= 22.1 Limiting Width to Thickness Ratio for Fv= .4 *Fy: AWSL= 63.3 Allowable Shear Stress: Fv= 14.4 KSI Design Requirements Comparison: Nominal Moment Strength: Mn= 28512 FT -LB Controlling Moment: Mu= 13054 FT -LB U - ../ Page: 2 Multi-Loaded Beamt AISC 9th Ed ASD 1Ver. V4020965 .' . . •:. , By: A. HELGE DORDALJBERNHOFT , PHOENIX DESIGN on: 07-24-1997 Project: FUJI - Location: BEAM t3 . . . . 6.065 FT From Left Support Nominal Shear Strength: Vn= 31219 ' LB . . Maximum Shear: V= 5679 . , LB Moment of Inertia: Irea 26 IN4 I= 58 IN4 ' Multi-Loaded Beam( AISC; 9tn to mu j ver. v4ukuwoo y: A. HELGE r.RDAUBERNHOFT , PHOENIX DESIG)" ,on: 07-24-1997 S8x18.4 / S Shapes / Steel Beam Project: FUJI - Location: BEAM * 3 RLZ= 3325 LB RD2= 627. LB RT2= 3953 LB _ M t Multi- Loaded Beam( AISC 9th Ed ASD 1 Ver. V4020965 �y�� By: A. HELGE DORDAUBERNHOFT , PHOENIX DESIGN on: 07 -24 -1997 Project: FUJI - Location: BEAM # 4 Summary: A36 S8x18.4 x 12.67 FT Section Adequate By: 82.5% Controlling Factor: Moment of Inertia Deflections: Dead Load: DLD= 0.04 IN Live Load: LLD= 0.23 IN = U657 Total Load: TLD= 0.27 IN = U569 End Reactions(Left Side): Live Load: RL1= 3641 LB Dead Load: RD1= 635 LB Total Load: RT1= 4276 LB End Reactions(Right Side): Live Load: RL2= 4694 LB - Dead Load: RD2= 662 LB Total Load: RT2= 5355 LB Bearing Length Regd.(Left) : BL1= 1.00 IN Bearing Length Reqd.(Right): BL2= 1.00 IN Bearing for P3: BL_P3= 1.00 IN Beam Data: Span: .. L= 12.67 FT Maximum Unbraced Span: Lu= 0.0 FT Live Load Deflect. Criteria: L/ 360 Total Load Deflect. Criteria: U 240 Uniform Load: Live Load: wL= 500 PLF Dead Load: wD= 80 PLF. Beam Self Weight: BSW= 18 PLF Total Load: wT= 598 PLF Concentrated Load P3: Live Load: PL3= 2000 LB Dead Load: PD3= 50 LB Total Load: PT3= 2050 LB Location: X3= 9.67 FT Properties for:A36 S8x18.4 Yield Stress: Fv= 36 KSI Depth: d= 8.00 N Web Thickness: tw= 0.27 N Flange Width: bf= 4.00 N Flange Thickness: tf= 0.43 N Distance to Web Toe of Fillet: k= 1.00 N Moment of Inertia About X -X Axis: Ixx= 57.6 N4 Section Modulus About X -X Axis (Calculated): Sxx= 14.4 N3 Radius of Gyration of Compression Flange + 1/3 of Web: rt= 1.05 N Design Properties per AISC Steel Construction Manual: Flange Buckling Ratio: FBR= 4.70 Allowable Flange Buckling Ratio: AFBR= 10.83 Web Buckling Ratio: WBR= 29.52 Allowable Web Buckling Ratio: AWBR= 106.67 Controlling Unbraced Length: Lb= 0.0 FT Limiting Unbraced Length for Fb= .66 *Fy: Lc= 4.223 FT Allowable Bending Stress: Fb= 23.76 KSI Web Width to Thickness Ratio: h /tw= 22.1 Limiting Width to Thickness Ratio for Fv= .4 *Fy: AWSL= 63.3 Allowable Shear Stress: Fv= 14.4 KSI Design Requirements Comparison: Nominal Moment Strength: Mn= 28512 FT -LB Controlling Moment: Mu= 15279 FT -LB .,. Page : 2 ,-,- Multi- Loaded Beamf AISC 9th Ed ASD 1 Ver V4020965 By: A. HELGE;DORDAUBERNHOFT PHOENIX DESIGN on: 07 -24- 1997 :. roject: FUJI - ;Location: BEAM # 4 7.147 FT From Left Support Nominal Shear Strength: Vn= 31219 LB Maximum Shear: V= 5355 LB Moment of Inertia: Ireq 32 _ IN4 _ ` I_ 58 IN4 Mti Iti-Loaded Beam( AISC 9th Ed ASD j Ver. V4020965 ORDAUBERNHOFT , PHOENIX DEW on 07-24-1997 S8x18.4 / S Shapes / Steel Beam Project: FUJI - Location: BEAM *4 wL 500 PLF wD = 80 PLF. L= 12.67 Ft , . 7- 24-- _49144 o + 14,4 kj \c pt 0 . 5 ci,"0 4,31Z 4 14 5 112 ) 10905" X 3 4. 2,3,7 y 7 4. is S3I g X IT — 9 it' 4 I 3C7ZZ \ - 77g2 4,- 17.7g \ 7 -k-,\ -4 Z299.\ 02,q7 23 +250 - 4c1,34 2 X 7 — 109 05' ;< ... 4-914-1 V. t 3 tt//g & 53 X'4 -23 _ x 177t2XV - 757 - 7/ 1c 7C:7/ A if 9 z4. Kr/ = 37,8 CI '- ‘..j , 0 „:,; i4.42 2, 51.9 L." 2 Zy17 =d J4f - wor5522 �roa L L 'ZS ' 2'16925 7X2.'i.89521 - ' X ZS19 )► '� V ,� IS -fi 7b? . _ ,x2 "sss82I - 9X2519 + zX2519 = .frkv 1I' •'1 • • 6' z\ = - z'sz\ ` .9V LI)za_ 51.x-119 4 11 "LM + c °•S5 ' \ .X 2•"3Z g x /5I7 + • X7.19} : Z W L•1 x2519 + ¶ i 7.12 +. I.XL64. r • quare Footing Design f 94 UBC (91 NDc Ver. V4020965 By: A. HELGE DORDAL /BERNHOFT , PHOENIX DESIGN on: 07 -22 -1997 Project: FUJI - Location: FTG A Summary: Size: 3.0 FT x 3.0 FT x 15.00 IN Reinforcement: #5 BARS @ 15.00 IN O.C. ENV Or (3) #5 BARS E/W Footing Loads: Live Load: Dead Load: Total Load: Ultimate factored load: Footing Properties: Allowable soil bearing pressure: Effective soil bearing pressure: Concrete compressive strength: Reinforcing steel yield strength: Concrete reinforcement cover: Selected Size: Length: Width: Area: Ultimate bearing pressure: Column Base Dimensions: Length: Width: Footing Size Selection: Required footing area: Minimum footing size required: Footing depth based on shear stresses: Selected footing depth: Effective steel depth: Punching Stress Calculations: Critical perimeter: Punching shear: • Punching shear stress: Allowable punching shear stress: Beam shear stress calculations: Beam shear: Beam shear stress: Allowable beam shear stress: Bending Requirements: Factored moment: Concrete compressive block depth: Minimum Steel Requirements: Steel required based on moment: Minimum code required reinforcement: Controlling reinforcing steel: Selected reinforcement: PL= 14182 LB PD= 1 LB PT= 14183 LB Pu= 24110 LB Qs= 2000 PSF Qe= 1813 PSF F'c= 2500 PSI Fv= 40000 PSI c= 3.00 IN L= 3.0 FT W= 3.0 FT A= 9.0 SF Qu= 2679 PSF I= 6.00 IN w= 6.00 IN Areq= 7.82 SF Lreq= 2.8 FT D= 15.00 IN d= 11.06 IN Bo= 68.25 IN Vu1= 18694 LB vu1= 29 PSI vc1= 200 PSI Vu2= 2637 LB vu2= 8 PSI vc2= 100 PSI Mu= 75345 IN -LB a= 0.10 IN As(1)= 0.06 IN2 /FT As(2)= 0.08 IN2 /FT As read= 0.08 IN2/FT #5 BARS @ 15.00 IN. O.C. As= 0.25 IN2/FT 17 Square Footing Design( 94 UBC (91 NDkri Ver. V4020965 Bv: A. HELGE DORDAUBERNHOFT , PHOENIX DESIGN on: 07 -22 -1997 Proiect: FUJI - Location: FTG B Summary: Size: 3.75 FT x 3.75 FT x 15.00 IN Reinforcement: *5 BARS @ 18.00 IN O.C. EIW Or (3) #5 BARS ENV Footing Loads: Live Load: Dead Load: Total Load: Ultimate factored Toad: Footing Properties: Allowable soil bearing pressure: Effective soil bearing pressure: Concrete compressive strength: Reinforcing steel yield strength: Concrete reinforcement cover: Selected Size: Length: Width: Area: Ultimate bearing pressure: Column Base Dimensions: Length: Width; Footing Size Selection: Required footing area: Minimum footing size required: Footing depth based on shear stresses: Selected footing depth: Effective steel depth: Punching Stress Calculations: Critical perimeter: Punching shear: Punching shear stress: Allowable punching shear stress: Beam shear stress calculations: Beam shear: Beam shear stress: Allowable beam shear stress: Bending Requirements: Factored moment: Concrete compressive block depth: Minimum Steel Requirements: Steel required based on moment: Minimum code required reinforcement: Controlling reinforcing steel: Selected reinforcement: PL= 23000 LB PD= 1 LB PT= 23001 LB Pu= 39101 LB Qs= 2000 PSF Qe= 1813 PSF F'c= 2500 PSI Fv= 40000 PSI c= 3.00 IN L= 3.75 FT W= 3.75 FT A= 14.06 SF Qu= 2781 PSF I= 6.00 IN w= 6.00 IN Areq= 12.69 SF Lreq= 3.56 FT D= 15.00 IN d= 11.06 IN Bo= 68.25 IN Vu1= 33480 LB vu1= 52 PSI vc1= 200 PSI Vu2= 7332 LB vu2= 17 PSI vc2= 100 PSI Mu= 165203 IN -LB a= 0,17 IN As(1)= 0.11 IN2 /FT As(2)= 0.15 IN2 /FT As regd= 0.15 IN2 /FT *5 BARS @ 18.00 IN. O.C. As 0.20 IN2/FT Square Footing Design 194 UBC (91 NDS)1 Ver. V4020965 By: A. HELGE DORDAL /BERNHOFT , PHOENIX DESIGN on: 07 -22 -1997 Proiect: FUJI - Location: FTG C Summary: Size: 4.5 FT x 4.5 FT x 15.00 IN Reinforcement: #5 BARS @ 12.00 IN O.C. EMI Or (5) #5 BARS E/W Footing Loads: Live Load: Dead Load: Total Load: Ultimate factored Toad: Footing Properties: Allowable soil bearing pressure: Effective soil bearing pressure: Concrete compressive strength: Reinforcing steel yield strength: Concrete reinforcement cover: Selected Size: Length: Width: Area: Ultimate bearing pressure: Column Base Dimensions: Length: Width: Footing Size Selection: Required footing area: Minimum footing size required: Footing .depth based on shear stresses: Selected footing depth: Effective steel depth: Punching Stress Calculations: Critical perimeter: Punching shear: Punching shear stress: Allowable punching shear stress: Beam shear stress calculations: Beam shear: Beam shear stress: Allowable beam shear stress: Bending Requirements: Factored moment: Concrete compressive block depth: Minimum Steel Requirements: Steel required based on moment: Minimum code required reinforcement: Controlling reinforcing steel: Selected reinforcement: PL= 35560 LB PD= 1 LB PT= 35561 LB Pu= 60453 LB Qs= 2000 PSF Qe= 1813 PSF F'c= 2500 PSI Fv= 40000 PSI c= 3.00 IN L= 4.5 FT W= 4.5 FT A= 20.25 SF Qu= 2985 PSF I= 6.00 IN w= 6.00 IN Areq= 19.62 SF Lreq= 4.43 FT . D= 15.00 IN d= 11.06 IN Bo= 68.25 IN Vu1= 54418 LB vu1= 85 PSI vc1= 200 PSI Vu2= 14484 LB vu2= 29 PSI vc2= 100 PSI Mu= 322418 IN -LB a= 0.29 IN As(1)= 0.18 IN2 /FT As(2)= 0.24 IN2 /FT As regd= 0.24 IN2 /FT #5 BARS @ 12.00 IN. O.C. As= 0.31 IN2 /FT Square Footing Design ( 94 UBC (91 NDS)1 Ver. V4020965 By: A. HELGE DORDAL /BERNHOFT , PHOENIX DESIGN on: 07 -22 -1997 Project: FUJI - Location: FTG D & DD Summary: Size: 4.25 FT x 4.25 FT x 15.00 IN Reinforcement: #5 BARS @ 15.00 IN O.C. EMI Or (4) #5 BARS E/W Footing Loads: Live Load: Dead Load: Total Load: Ultimate factored load: Footing Properties: Allowable soil bearing pressure: Qs= 2000 PSF Effective soil bearing pressure: Qe= 1813 PSF Concrete compressive strength: F'c= 2500 PSI Reinforcing steel yield strength: Fv= 40000 PSI Concrete reinforcement cover: c= 3.00 IN Selected Size: Length: L= 4.25 FT Width: W= 4.25 FT Area: A= 18.06 SF Ultimate bearing pressure: Qu= 2738 PSF Column Base Dimensions: Length: I= 6.00 IN Width: w= 6.00 IN Footing Size Selection: Required footing area: Area= 16.44 SF Minimum footing size required: Lreq= 4.05 FT Footing depth based on shear stresses: Selected footing depth: D= 15.00 IN Effective steel depth: d= 11.06 IN Punching Stress Calculations: Critical perimeter: Bo= 68.25 IN Punching shear: Vu1= 43924 LB Punching shear stress: vu1= 68 PSI Allowable punching shear stress: vc1= 200 PSI Beam shear stress calculations: Beam shear: Vu2= 11092 LB Beam shear stress: vu2= 23 PSI Allowable beam shear stress: vc2= 100 PSI Bending Requirements: Factored moment: Mu= 245482 IN -LB Concrete compressive block depth: a= 0.23 IN Minimum Steel Requirements: Steel required based on moment: As(1)= 0.15 IN2 /FT Minimum code required reinforcement: As(2)= 0.20 IN2 /FT Controlling reinforcing steel: As read= 0.20 IN2 /FT Selected reinforcement: #5 BARS @ 15.00 IN. O.C. As 0.25 IN2 /FT 25800 LB 4000 LB 29800 LB 49460 LB • . PL= PD= PT= Pu= isomminhriAii.loorwsztswa Columnf AISC 9th Ed ASD 1Ver. V4020965 By: A. HELGE DORDAUBERNHOFT , PHOENIX DESIGN on: 07-19-1997 Project: FUJI - Location: UNDER BEAM # 5 (TYP) Summary: 6 X 6 X 3/8 TS -ASTM A500 x 12.0 FT Section Adequate By: 84.1% Base Reactions: Live: Dead: Total: Maximum Unbraced Length (X Axis): • Maximum Unbraced Length (Y Axis): Column Section: (X Axis): • Column Section: (Y Axis): Axial Loads: Live Loads: • Dead Loads: Total Loads: Column Data: Length: Column End Condition: Eccentricity (X Axis): Eccentricity (Y Axis): Column Design Properties: Steel Yield Strength: Modulus of Elasticity: Column Bending Coefficient: Area: Moment of Inertia (X Axis): Moment of Inertia (Y Axis): Radius of Gyration Ratio: Radius of Gyration (X Axis): Radius of Gyration (Y Axis): Section Modulus (X Axis): Section Modulus (Y Axis): Column Compression Calculations: KUr Ratio (X Axis): KL/r Ratio (Y Axis): Controlling Direction: Compressive Stress: Column Slenderness Ratio: Allowable Compressive Stress: Column Bending Calculations: Eccentricity Moment (X Axis): Eccentricity Moment (Y Axis): Bending Stress (X Axis): Bending Stress (Y Axis): Allowable Bending Stress: Euler's Stress (X Axis): Euler's Stress (Y Axis): Combined Stress Calculations: Using AISC Formula H1-1: Using AISC Formula H1-2: Using AISC Formula H1-3: • RL= 35560 RD= 331 RT= 35891 Lx= 0.0 Lv= 0.0 dx= 6.00 • dy= 6.00 PL= 35560 PD= 1 PT= 35561 L= 12.0 Ke= 1.0 ex= 0.00 ey= 0.00 Fy= 46000 E= 29000000 Cm= 1.00 A= 8.08 Ix= 41.6 1V= 41.6 rx/ry= 1.00 rx= 2.27 rv= 2.27 Sx= 13.9 Sy= 13.9 KLx/rx= KLy/ry= fa= Cc= Fa= 0.0 0.0 (Y Axis) 4401 PSI 111.6 27600 PSI Mx= 0 My= 0 fbx= 0 %V= 0 Fbx=FIN= 30360 1534367000000000 1534367000000000 CSF(1)= CSF(2)32 CSF(3)= 0.16 0.16 0.16 LB LB LB FT FT IN IN LB LB LB FT IN IN PSI PSI IN2 IN4 IN4 IN IN . IN3 IN3 IN-LB IN-LB PSI PSI PSI PSI PSI 74- 2 e).14 ,55 1.33 0.71- LL e • 9,75 „ I P kS ,e3 "X /0 vx )s i tudc JCL 1,,/(4) 7 x 34 6.1ks U..yAcLr ( "= cock 001-2. c '' _ 2500 Rs 1 ( . • 4 - - t tins lFi{9�'�'797ib1`N+tMa7s16�IdE WiLrEvPAnn�1 3. l - 211 .X : 04.cC A a 144 6 ‘• 2 " o, 5 E. o. 9 - 0 i74 o -S r 4- 75 - 0 o , 4 r 4.A 4q. °.45 r 12,45 1r ___ u, 2. _ 1/.54 iz u 12,4T P 35,54 s 26" s 8 X 1 2,Y IZ _ U,. \cbA' r3 e■ 4 t S 6 =23k -z4-.-11 ../cuiVlcvt 7'-9 /2 "X /2" id.,.. TP _ a CAL A' B e 4 r- 1j p, essu e- Z 3 , 6 , I� SCSI • P !3 XN i2�X�2 Pi= C/2- (0,4.50 )2/2. 3./S 7-'24-1997 f _ [2- (6,8)(0312 6- 1 14 r L4) %; X18" g 1t. I •`3 N piaL 3.6 iH (15E /2 la' .1( ' 3.6 0 .)6 . G am 1 . 9 c vernl ti of 4f' • cam. o; 5 _Gx6 3/ A- Soo 1 • N . e • 6 tex►Z (*. ■5 (11 1, 11l 2 ►1 !st___ A ►b4 BufrA b ; /4,1 4°4 13/4 y ye z' . 1• So k /i..p A-G. NEW 4X AI' -'.Z 4 4 46 ►4 141/4, UNITS 5,14 w =to /tiv ►3 44 k4' LA) so ?� r1O 7 Multi- Loaded Beam[ 94 UBC (91 NDS) ] Ver. V4020965 By: A,HELGE DORDAUBERNHOFT, , PHOENIX DESIGN & ENGINEERING on: Project: FUJI - Location: HVAC UNITS LEFT SIDE Summary: 3.50 IN x 5.50 IN x 7.57 FT / #2 - DOUGLAS FIR -LARCH - Dry Use Section Adequate By: 89.1% Controlling Factor: Section Modulus / Depth Required 4.00 In Deflections: Dead Load: Live Load: Total Load: End Reactions(Left Side): Live Load: Dead Load: Total Load: End Reactions(Right Side): Live Load: Dead Load: Total Load: Bearing Length Regd.(Left) : Bearing Length Reqd.(Right): Beam Data: Span: Maximum Unbraced Span: Live Load Duration Factor: Live Load Deflect. Criteria: Total Load Deflect. Criteria: Uniform Load: Live Load: Dead Load: Beam Self Weight: Total Load: Concentrated Load P1: Live Load: Dead Load: Total Load: Location: Properties For: #2- DOUGLAS FIR -LARCH Bending Stress: Shear Stress: Modulus of Elasticity: Stress Perpendicular to Grain: Adjusted Properties: Fb' (Tension): Adjustment Factors: Cd =1.00 Cf=1.30 Fv': Adjustment Factors: Cd =1.00 Design Requirements: Maximum Moment: 4.36 FT From Left Support Shear (© d from beam end): Comparisons With Required Sections: Section Modulus: Area: Moment of Inertia: DLD= LLD= TLD= RL1= RD1= RT1= RL2= RD2= RT2= BL1= BL2= L= Cd= U U. wL= wD= BSW= wT= PL1= PD1= PT1= X1= Fb= Fv= E_ Fc_perp= Fb' Fv'= M= V= Sreq= S= Areq= A= Ireq= 1= 07 -24 -1997 189 LB 198 LB 388 LB 189 LB 222 LB 412 LB 0.18 IN 0.19 IN 7.57 FT 0.0 FT 1.00 360 240 875 PSI 95 PSI 1600000 PSI 625 PSI 1138 PSI 0.06 IN 0.05 IN = U1909 0.11 IN = U816 50 PLF 30 PLF 5 PLF 85 PLF 0 LB 158 LB - 158 LB 4.36 FT 95 PSI 885 FT -LB 373 LB 9.4 N3 17.6 N3 5.9 N2 19.2 N2 14.3 N4 48.5 N4 Multi-Loaded Beam( 94 UBC (91 NDS) I Ver. V4020965 By: A.HELGE DOAUBERNHOFT, , PHOENIX DESIGN & ENG(" 7.RING on 07=24 #2/ DOUGLAS FIR-LARCH / Dimensional Lu der Project: FUJI - Location: HVAC UNITS LEFT SIDE V RL1= 189 LB RD1= 198 LB RI1= 388 LB L= 7.57 Ft . • RL2= 189 LB • RD2= 222 LB RT2= 412 LB Multi- Loaded Beam[ 94 UBC (91 NDS) ] Vera V4020965 By: A.HELGE DORDAL/BERNHOFT, , PHOENIX DESIGN & ENGINEERING on: 07 -24 -1997 Project: FUJI.- Location: HVAC UNIT RIGHT SIDE Summary: 3.50 IN x 5.50 IN x 7.57 FT /#2 - DOUGLAS FIR - LARCH- Dry Use Section Adequate By: 104.6% Controlling Factor: Section Modulus / Depth Required 3.84 In Deflections: Dead Load: DLD= 0.06, IN Live Load: LLD 0.05 IN = L/1909 Total Load:, TLD= 0.11 IN = L/844 End Reactions(Left Side): Live Load: RL1= 189 LB Dead Load: RD1= 244 LB Total Load: RT1= 433 LB End Reactions(Right Side): Live Load: RL2= 189 LB Dead Load: RD2= 183 LB Total Load: RT2= 372 LB Bearing Length Regd.(Left) : BL1= 0.20 IN Bearing Length Regd.(Right): BL2= 0.17 IN Beam Data: Span: L= 7.57 FT Maximum Unbraced Span: Lu= 0.0 FT Live Load Duration Factor: Cd= . 1.00 Live Load Deflect Criteria: L/ 360 Total Load Deflect. Criteria: L/ 240 Uniform Load: Live Load: wL= 50 PLF Dead Load: wD= : 30 PLF Beam Self Weight: BSW= 5 PLF Total Load: wT= 85 PLF Concentrated Load P1: Live Load: PL1= 0 LB Dead Load: PD1= 164 LB - Total Load: PT1= 164 LB Location: X1= 2.38 FT Properties For: #2- DOUGLAS FIR- LARCH Bending Stress: Fb= 875 PSI Shear Stress: Fv= 95 PSI Modulus of Elasticity: E= 1600000 PSI .. Stress Perpendicular to Grain: Fc_perp= 625 PSI Adjusted Properties: Fb' (Tension): Fb'= 1138 PSI Adjustment Factors: Cd =1.00 Cf=1.30 Fv': Fv'= 95 PSI Adjustment Factors: Cd =1.00 . Design Requirements: Maximum Moment: 3.176 FT From Left Support Shear (@ d from beam end): Comparisons With Required Sections: ' Section Modulus: Area: Moment of Inertia: M= V= Sreq= S= Areq= A = . Ireq= 817 394 8.7 17.6 6.3 19.2 13.9 48.5 FT -LB LB IN3 IN3 IN2 IN2 IN4 IN4 Multi Loaded Beam[ 94 UBC (91 NOS) ] Ver. V407,0965 PAUBERNHOFT, , PHOENIX DESIGN & ENC(T )ERING on: 07-24-1997 #2/ DOUGLAS FIR-LARCH / Dimensional L fiber Project FUJI - Location: HVAC UNIT RIGHT SIDE RL1=.189 LB • RD1= 244 LB RT1= 433 LB • . . . .1 ; 1•:, t•.,,, wL 50 PLF WD = 30 PLF L= 7.57 Ft • RL2= 189 LB RD21 183 LB RT2= 372 LB Multi-Loaded Beam( 94 UBC (91 NDS) j Ver. V4020965 By: A.HELGE DORDAL/BERNHOFT, PHOENIX DESIGN & ENGINEERING on: 07-25-1997 Project: FUJI - Location: HVAC UNIT LEFT SIDE Summary: 3.50 IN x 5.50 IN x 7.57 FT / #2- DOUGLAS FIR-LARCH - Dry Use Section Adequate By: 121.1% Controlling Factor: Section Modulus / Depth Required 3.70 In Deflections: Dead Load: DLD= Live Load: LLD= Total Load: TLD= End Reactions(Left Side): Live Load: RL1= Dead Load: RD1= Total Load: RT1= End Reactions(Right Side): Live Load: RL2= Dead Load: RD2= Total Load: RT2= Bearing Length Reqd.(Left) : BL1= Bearing Length Reqd.(Right): BL2= Beam Data: Span: L= Maximum Unbraced Span: Lu= Live Load Duration Factor Cd= Live Load Deflect Criteria: U Total Load Deflect Criteria: L/ Uniform Load: Live Load: wL= 50 PLF Dead Load: wD= 30 PLF Beam Self Weight: BSW= 5 PLF Total Load: wT= 85 PLF Concentrated Load P1: Live Load: PL1= 0 LB Dead Load: PD1= 177 LB • Total Load: PT1= 177 LB Location: X1= 4.86 FT Properties For #2- DOUGLAS FIR-LARCH Bending Stress: Fb= 875 PSI Shear Stress: Fv= 95 PSI • Modulus of Elasticity: E= 1600000 PSI Stress Perpendicular to Grain: Fc_perp= 625 PSI • Adjusted Properties: • Fb' (Tension): • Fb' = 1308 PSI Adjustment Factors: Cd=1.15 Cf=1.30 Fv': Fv'= 109 PSI Adjustment Factors: Cd=1.15 • Design Requirements: • Maximum Moment: M= 870 4.534 FT From Left Support Shear (@ d from beam end): V= 395 Comparisons With Required Sections: Section Modulus: Area: Moment of Inertia: Sreq= S= Areq= A= I req= I= 0.06 0.05 0.11 189 195 384 189 245 434 • 0.18 0.20 7.57 0.0 1.15 360 240 8.0 17.6 5.5 19.2 14.5 48.5 IN IN = L/1909 IN = U808 LB LB LB LB LB LB IN . IN FT FT FT-LB LB IN3 IN3 IN2 IN2 IN4 IN4 Mutt-Loaded Beam( 94 UBC (91 NDS) ] Ver. V4n20965 By: A.HELGE '... PHOENIX DESIGN & EN( 12ERING on: 07-25-1997 #2 DOUGLAS FIR-LARCH / Dimensional L (fiber • Project: FUJI - Location: HVAC UNIT LEFT SIDE ' . Multi-Loaded Beam[ 94 UBC (91 NDS) ] Ver. V4020965 By: A.HELGE DORDAL/BERNHOFT, PHOENIX DESIGN & ENGINEERING on: Project: FUJI - Location: HVAC RIGHT SIDE Summary: 3.50 IN x 5.50 IN x 7.57 FT / #2 - DOUGLAS FIR-LARCH - Dry Use Section Adequate By: 127.9% Controlling Factor: Section Modulus / Depth Required 3.65 In Deflections: Dead Load: DLD= Live Load: LLD= Total Load: TLD= End Reactions(Left Side): Live Load: RL1= Dead Load: RD1= Total Load: RT1= End Reactions(Right Side): Live Load: RL2= Dead Load: RD2= Total Load: RT2= Bearing Length Reqd.(Left) : BL1= Bearing Length Reqd.(Right): BL2= Beam Data: Span: L= Maximum Unbraced Span: Lu= Live Load Duration Factor: Cd= Live Load Deflect. Criteria: Total Load Deflect. Criteria: LJ Uniform Load: Live Load: Dead Load: Beam Self Weight: Total Load: Concentrated Load P1: Live Load: Dead Load: , Total Load: Location: Properties For: #2- DOUGLAS FIR-LARCH Bending Stress: Shear Stress: Modulus of Elasticity: Stress Perpendicular to Grain: Adjusted Properties: Fb' (Tension): Adjustment Factors: Cd=1.15 Cf=1.30 Fv': Adjustment Factors: Cd=1.15 Design Requirements: Maximum Moment: M= 3.106 FT From Left Support Shear (@ d from beam end): V= Comparisons With Required Sections: Section Modulus: Sreq= S= Area: Areq= A= Moment of Inertia: Irecr wL= wD= BSW wT= PL1= PD1= PT1= X1= Fb= Fv= E= Fc_perp= Fb'= Fv'= 07-25-1997 0.06 IN 0,05 IN = U1909 0.11 IN U820 189 LB 257 LB 446 LB 189 LB 189 LB 378 LB 0.20 IN 0.17 IN 7.57 FT 0.0 FT 1.15 360 240 50 PLF 30 PLF 5 PLF 85 PLF 0 LB 183 LB' 183 LB 2.38 FT 875 PSI 95 PSI 1600000 PSI 625 PSI 1308 PSI 109 PSI 844 FT-LB 407 LB 7.8 N3 17.6 N3 5.6 N2 19.2 N2 14.3 N4 48.5 N4 PL1= 0 Lb • PD1= 183 Lb 2.38 Ft. Multi Loaded Beam( 94 UBC (91 NDS) I Ver. V4020965 By: AHELGE ODAUBERNHOFT, , PHOENIX DESIGN & ENC_ EERING on: 07-25-1997 #2/ DOUGLAS FIR-LARCH / Dimensional L. doer Project: FUJI - Location: HVAC RIGHT SIDE v L\ RL2= 189 LB RD2= 189 LB • RT2= 378 LB !' • AST. FRANC 19 1 /6UT1ON PANT. s 1/7 LCAC. TLr•• HALL NO II•8LATION MN 74 BAST. 5 112 COW, T1LT.UP WALL NO INNIATION Or. 7.7 q N _ 4 I , II � s JL 1I 4 ¶ II j o ' i o�C R w r. 1 ao0� - II I I 701750 FT II � E It _ ° = = = = BOST 9 :r2 CONC. TLTPP HALL 0 •I•ALATON 00' . 24 N N .S 3 3..3. 3. 3 R��. CZ �3. 33 �YJ I I I II ; w 1L ?NO' •T• I P 0•41d ROOFb • • R.10 NN LPA3E LMLLS • R•N AK • hal •R•PT .AIL 11 EAST. ARMC NN.:S • ••• CAST, CONG. F14.1.b • (. • CC•L..ulLS MOCa.LATED) ' . MT d1.A21.9 • 5 it COORS •.NIIALATLO .TAMrTTR SLAB • WOW-A= 1•EAT!0 SPACE FUJI TruColor 710 A70WER PARK EAST IUWLA HAN/NOTCH •HAL1 00 !4 ICA l COGttD 1141IA41IR0.11 LPA t91V 5afr. 10.N 5a011d4A110NCHLWB 11624 SO FT � 1401R-14 INSAAT104 hr,24) 1 EN R•I. 16LAnoN • II II (6 .2.7 — = = =ra. = = = = = = = se = � IJU�.i,.x = —:. =-.. P ATED 1h15 10 16L.AfION•CELI10 EAI611 ■R.I Qt.LAnTN • PULL 11 » • 2 +1 KATE, 1E1WR SPACE II STORAd6 LPA • W 52 PT n 1 .40 SO PT I' N.R.E G. INFORMATION 5417 yr•r II - r •ih ■•!0 •6LAIIC•FCE1LOp PA 3 Hi SO I 1� PASWK '11�LL 604 SO FT N N.R.F.G, INFORMATION It••04f•yJY.•41 1.••/.• •._v 01•••••••• • •1 .....r/ 0..180 •I•••r•4 w *NI 114 55 =• an r• I.vr eara Nwd•••••• r•4 Mr .44 WN ft.., •••• 2081• •• U1.•• f/• I.1•Mw••• 50.• w 4 1 1n. Off= •H.••wM —M. 4245 Ww 8 A N...••rw1 W.• 154•44•4. V N. •1•84 1.4••.••••.0 w• .■30 •••01.0••• 444 1 •1 y - Lam. ii Ii L +_ - - R saa== a ax4 Cr s a .1=r VOA. 110 MWO •1.LATION EA15T• • V2• GONG TILSJP NALL ROO • 21') 140 IILW.AT1O44 R21491014 PER e1w•:e oePl LETTE/L e-s-t FUJ T.vokr 710 A•MVER PARK E. PATHLA, NASNL4TON PPO0I:t w tn.Cotor 7'T0 /MOVER PARR E. 7WLA. NA•H. 51NA PAKAgALA NAB G. MOR$ATLON I Ro at,o ol • cL N.g -7 Co-- ?tC.Port-MANcC - 4 ?66.T1oN) 6fAce 1-\EA- -- o . rtii i 1..)4L.Juol Nco 1-16.:. kr A - N 4 ) .i - rAit.e. 67 A T_ 711 VAT - UAL A . § 1 - 0 a) w d c Z W T - Vvc , r Av't + UcT A wr fr 5sT up- A, I2 6r, Fc -- c4 t.0 ')vJT4 u€6 Uv41 A vr.-r r tkl 12i,(-e0 115.. 20 UA.t - a‘ 572.6.°10 " .4.44.1.100.0.4 5 rJ�l • 7P-u, cot ocz Preopo%o OA u Ap tivPote • 1 16. Poutak, Uorz A aR 'r U w A‘o,.+ �w 414 + Uvc 4v4- + UD / a + F Ps 6 .);s SSE Fi4'J\4 wtS CN ekrc z- 2Q clAt" 06. a 2t2) s �• (1/5F-4-Ake r-,c G JO,110 r Co{^L, /Sato 0.0 A v& = 114 St 1 ) U� r h Ih 4u 14+cd (ttc,1zt ( ZO AD c- V F� = 1.)»;t-SU(6 -LA a(4 0.7 ) � p� - 2t0Lf _ U A ( e 4+13.7,4, < (j A T C T r. ��T 5 zz!► .1 f rero4 r> C e t,t t-AUCLu p E ZEQU I PE. } I C JOTS e 54, z teoel. 05 2155 102. o lb° 7.04' AO V �r 2 413 , Z6 PROJECT:I FUJI TruColor INC. 770 ANDOVER PARK EAST TUKWILA, WASHINGTON 98188 ENGINEER: A. HELGE DORDAL, P.E. c/o PHOENIX DESIGN & ENGINEERING 702 BROADWAY, SUITE 103 TACOMA WASHINGTON, 98402 RECEIVED CITY OF TUKWILA 1 5 PERMIT CENTER ?iittifti� • ,t I EXIST. (% _a POST l ry I1 tt 5 58 x 15.4n © 4' O.G. I —KNEE BRACING (TYP) 4" x 4" x 1/4" 1 Iv HEST SIDE 1 BEAM 1 �, O 1 x l SS x 18.4I04' O.G. 3 1 KNEE BRACING (TYP) 4'x4 "x 1/4" 2x12 DF #2 © 6" O.0 TYPICAL /2" x 1 COLUMN MAN CHOLS N 1 (q) TYPICAL FLOOR GRATING I m — �-2 x 12 LE- SIMPSON HU212 12' -8 1/2" 0I 1 2q -5 56 x 1254t 58 x18.4 # ©4' O.G. EAST 51DE I BEAM TYPICAL 20004 LOAD FROM . . CHEM. MIX TANK 6 "x 6" WF BEAM METAL 56 x 12. 4-l S8 x 18.41 © 4' O.G. 4I If— II— —II —H --- � — x 6 FRAMED HALL I2' -8 1/2" x 6 FRAMED (2) 2 x 12 ALL ( 2 x 12-- PEN FOR STAIRS 1 xl 56 x 12.54 zi EXIST. 2 x 6 FRAME HALL 3' sy I EXPIIES: 1 /is 6 ' P �— EXISTING 6" GONG. HALL I•R , $1∎1 4y:�iw Cantilever Floor Beam[ AISC 9th Ed ASD j Ver. V4020965 By: A.HELGE DORDAUBERNHOFT, , PHOENIX DESIGN & ENGINEERING on: 08 -13 -1997 Project: FUJI - Location: West Side / No tank load Summary: A36 S8x18.4 x 13.75 FT Section Adequate By: 356.0% Controlling Factor: Moment Deflections: Cant Tip 1 Live Load: Cant Tip 1 Total Load: Interior Span Live Load: Interior Span Total Load: End Reactions: Left End Total Load Reactions: LLD1= -0.02 TLD1= -0.03 LLD= 0.09 TLD= 0.11 - R1max= R1min= R2max= R2min= FS= 2287 0 LB LB 1964 LB 0 LB 1.5 Right End Total Load Reactions: Dead Load Uplift F.S.: Bearing Length Bearing Length Reqd.: BL1= 1.00 IN Bearing Length Regd.: BL2= 1.00 IN Beam Data: Span: L= 12.75 FT Maximum Unbraced Span: Lu= 0.0 FT Live Load Deflect. Criteria: U 360 Total Load Deflect. Criteria: U 240 Beam Loading: Dead Load: DL= 20 PSF Beam Self Weight: BSW= 18 PLF Cantilever End One: End Span: CS1= 1.0 FT Tributary Width: TW1= 2.0 FT • Live Load: LL1= 125 PSF Interior Span: Tributary Width: TW= 2.0 FT Live Load: LL= 125 PSF Beam Uniform Loading Summary: End One: Dead Load: wD1= 58 PLF End One: Live Load: wL1= 250 PLF Interior Span: Dead Load: wD= 58 PLF Interior Span: Live Load: wL= 250 PLF Properties for:A36 S8x18.4 Yield Stress: Fy= 36 KSI Depth: d= 8.00 N Web Thickness: tw= 0.27 N Flange Width: bf= 4.00 N Flange Thickness: tf= 0.43 N Distance to Web Toe of Fillet: k= 1.00 N Moment of Inertia About X -X Axis: lxx= 57.6 N4 Section Modulus About X -X Axis (Calculated): Sxx= 14.4 N3 Radius of Gyration of Compression Flange + 1/3 of Web: rt= 1.05 N Design Properties per AISC Steel Construction Manual: Flange Buckling Ratio: FBR= 4.70 Allowable Flange Buckling Ratio: AFBR= 10.83 Web Buckling Ratio: WBR= 29.52 Allowable Web Buckling Ratio: AWBR= 106.67 Controlling'Unbraced Length: Lb= FT Limiting Unbraced Length for Fb= .66 "Fy: Lc= 4.223 FT Allowable Bending Stress: Fb= 23.76 KSI Web Width to Thickness Ratio: hltw= 22.1 Limiting Width to Thickness Ratio for Fv= .4 "Fy: AWSL= 63.3 Allowable Shear Stress: Fv= 14.4 KSI Design Requirements Comparison: Nominal Moment Strength: Controlling Moment: 6.382 Ft From Left Support (End 1) Critical M created by combining all dead loads and w live loads. Nominal Shear Strength: Vn= 31219 LB Maximum Shear: V= 1978 LB At Interior Span Edge of Left Support (End 1) Critical V created by combining all dead loads and w and w1 live loads. Moment of Inertia: Trey= 12 IN4 1= 58 IN4 IN IN IN = U1719 IN = U1398 Mn= 28512 FT -LB Mu= 6252 FT -LB ntilever Floor Beam( AISC 9th Ed ASD I Ver. V400965 By A HELGE D AL/BERNHOFT, PHOENIX DESIGN & ENG (RING on 08-13-1997 S8x18.4 / S Shapes /Steel Beam Project FUJI - Location: West Side / No tank load 50 PLF 58 PLF wL =250 PLF wD= 58 PLF R1 min= 0 LB R2min= 0 LB .. R1 max= 2287 LB R2max= 1964 LB '°r1L',"f'Ef ; p.S..ij - S1:>.:i:'�lXr: v„3iid1aMeil r'r'•'i3k�i!: i':ti ?n:C? :Rx, J!T4;vlft34Y�p ikw' # }Zy4V2 +d^,k s"'MNttv�.4s= 7Mn[rai^e;4 G. aMMNC�+ t.. �rtrx! ho<..F,. Rnwn.: �•. n. n.. w. 4.`.• su.+ wweaxaanw. r».......:+.,.. www. �. rt+.. omure.. eL+ �.. aw +w..w..r...o.r. Cantilever Floor Beam AISC 9th Ed ASD ] Ver. V4020965 By: A.HELGE DORDAUBERNHOFT, , PHOENIX DESIGN & ENGINEERING on: 08 -13 -1997 Project: FUJI - Location: West Side I Beams Summary: A36 S8x18.4 x 13.75 FT Section Adequate By: 103.4% Controlling Factor: Moment of Inertia Deflections: Cant Tip 1 Live Load: Cant Tip 1 Total Load: Interior Span Live Load: Interior Span Total Load: End Reactions: Left End Total Load Reactions: Right End Total Load Reactions: Dead Load Uplift F.S.: Bearing Length Bearing Length Reqd.: Bearing Length Regd.: Bearing for P on interior span: Beam Data: Span: Maximum Unbraced Span: Live Load Deflect. Criteria: Total Load Deflect. Criteria:' Beam Loading: Dead Load: Beam Self Weight: Cantilever End One: End Span: Tributary Width: Live Load: Interior Span: Tributary Width: Live Load: Point Live Load: Point Dead Load: r Location: Beam Uniform Loading Summary: End One: Dead Load: End One: Live Load: Interior Span: Dead Load: Interior Span: Live Load: Properties for:A36 S8x18.4 Yield Stress: Depth: Web Thickness: Flange Width: Flange Thickness: Distance to Web Toe of Fillet: Moment of Inertia About X -X Axis: Section Modulus About X -X Axis (Calculated): Radius of Gyration of Compression Flange + 1/3 of Web: Design Properties per AISC Steel Construction Manual: Flange Buckling Ratio: Allowable Flange Buckling Ratio: Web Buckling Ratio: Allowable Web Buckling Ratio: Controlling Unbraced Length: Limiting Unbraced Length for Fb= .66 "Fy: Allowable Bending Stress: Web Width to Thickness Ratio: Limiting Width to Thickness Ratio for Fv=.4*Fy: Allowable Shear Stress: Design Requirements Comparison: Nominal Moment Strength: Controlling Moment: 5.978 Ft From Left Support (End 1) Critical M created by combining all dead loads Nominal Shear Strength: Maximum Shear: At Interior Span Edge of Left Support (End 1) Critical V created by combining all dead loads and P, w and w1 and P and w live loads. live loads. LLD1= -0.06 IN TLD1= -0.06 IN LLD= 0.21 IN = U732 TLD= 0.24 IN = L/627 R1max= 6245 LB R1min= 0 LB R2max= 4052 LB R2min= 0 LB FS= 1.5 BL1= 1.00 IN BL2= 1.00 IN BL_P= 1.00 IN L= 12.75 FT Lu= 0.0 FT L/ 360 U 240 DL= 20 PSF BSW= 18 PLF CS1= 1.0 FT TW1= 4.0 FT LL1= 125 PSF TW= 4.0 FT LL= 125 PSF PL= 2000 LB PD= 50 LB X= 1.5 FT wD1= 98 PLF wL1= 500 PLF wD= 98 PLF wL= 500 PLF Fy= 36 KSI d= 8.00 N tw= 0.27 N bf= 4.00 N tf= 0.43 N k= 1.00 N Ixx= 57.6 N4 Sxx= 14.4 N3 rt= 1.05 N FBR= 4.70 AFBR= 10.83 WBR= 29.52 AWBR= 106.67 Lb= 0.0 FT Lc= 4.223 FT Fb= 23.76 KSI h /tw= 22.1 AWSL= 63.3 Fv= 14.4 KSI Mn= 28512 FT -LB Mu= 13720 FT -LB Vn= 31219 LB V= 5647 LB 4/1,1 Cantilever Floor Beam[ AISC 9th Ed ASD ] Ver. V4020965 by: A.HELGE DORDALJBERNHOFT, , PHOENIX DESIGN & ENGINEERING on: 08-13-1997 Project: FUJI - Location: West Side I Beams' . Moment of Inertia; Irecr 28 IN4 58 IN4 � By A HELGE D . \LJBERNHOFT, , tiiever Floor Beam[ AISC 9th Ed ASD ] Ver. V40,20965 PHOENIX DESIGN & ENGI (RING on 08-13-1997 S8x18.4 / S Shapes / Steel Beam Project FUJI - Location: West Side I Beams PL= 2000 . LB ©1.5 Ft PO= 50LB @1:5 Ft wL= 500 PLF wD= 98 PLF ,. CS1 = =t ;.; L = Ft err'rted9�' ntd3kR, WS;? 7; yRi�ss. N.`'. tio� '+'t;�kMavi�;r ^ch:sn.s: �rv:.aspx+.M..rs rir.�srnwn Cantilever Floor Beam( AISC 9th Ed ASD ] Ver. V4020965 By: A.HELGE DORDAUBERNHOFT, , PHOENIX DESIGN & ENGINEERING on: 08 -13 -1997 Project: FUJI - Location: East Side No Tank Load Summary: A36 S8x18.4 x 15.75 FT Section Adequate By: 364.7% Controlling Factor: Moment Deflections: Interior Span Live Load: Interior Span Total Load: Cant Tip 2 Live Load: Cant Tip 2 Total Load: End Reactions: Left End Total Load Reactions: Right End Total Load Reactions: Dead Load Uplift F.S.: Bearing Length Bearing Length Reqd.: Bearing Length Reqd.: Beam Data: Span: Maximum Unbraced Span: Live Load Deflect. Criteria: Total Load Deflect. Criteria: Beam Loading: Dead Load: Beam Self Weight: Interior Span: Tributary Width: Live. Load: Cantilever End Two: End Span: Tributary Width: Live Load: Beam Uniform Loading Summary: Interior Span: Dead Load: Interior Span: Live Load: End Two: Dead Load: End Two: Live Load: Properties for:A36 S8x18.4 Yield Stress: Depth: Web Thickness: Flange Width: Flange Thickness: Distance to Web Toe of Fillet: Moment of Inertia About X -X Axis: Section Modulus About X -X Axis (Calculated): Radius of Gyration of Compression Flange + 1/3 of Web: Design Properties per AISC Steel Construction Manual: Flange Buckling Ratio: Allowable Flange Buckling Ratio: Web Buckling Ratio: Allowable Web Buckling Ratio: Controlling Unbraced Length: Limiting Unbraced Length for Fb=.66*Fy: Allowable Bending Stress: Web Width to Thickness Ratio: Limiting Width to Thickness Ratio for Fv= .4 "Fy: Allowable Shear Stress: Design Requirements Comparison: Nominal Moment Strength: Controlling Moment: 6.308 Ft From Left Support (End 1) Critical M created by combining all dead loads and w live loads. Nominal Shear Strength: Maximum Shear: At Interior Span Edge of Right Support (End 2) - Critical V created by combining all dead loads and w and w2 live loads. Moment of Inertia: LLD= TLD= LLD2= TLD2= R 1 max= R1 min= R2max= R2min= FS= L= Lu= U U DL= BSW= BL1= BL2= TW= LL= CS2= TW2= LL2= wD= wL= wD2= wL2= Fy= d= tw= bf= tf= k= Ixx= Sxx= rt= FBR= AFBR= WBR= AWBR= Lb= Lc= Fb= h /tw= AWSL= Fv= Mn= Mu= Ire= 0.09 0.11 -0.07 -0.08 1945 0 3000 0 1.5 1.00 IN 1.00 IN 12.75 FT 0.0 FT 360 240 20 PSF 18 PLF 2.0 FT 125 PSF 3.0 FT 2.0 FT 125 PSF 58 PLF 250 PLF 58 PLF 250 PLF 36 KSI 8.00 N 0.27 N 4.00 N 0.43 N 1.00 N 57.6 N4 14.4 N3 1.05 N 4.70 10.83 29.52 106.67 0.0 FT 4.223 FT 23.76 KSI 22.1 63.3 14.4 KSI 28512 FT -LB 6136 FT -LB Vn= 31219 LB V= 2075 LB IN = U1719 IN = U1430 IN IN LB LB LB LB 12 IN4 58 IN4 t 2 2 tilever Floor Beam( AISC 9th Ed ASD Ver. V4020965 By A.HELGE DO :? PHOENIX DESIGN & ENGItr7 on: , . S8x18A IS Shapes / Steel Beam ‘.. ; Project FUJI - Location: East Side No Tank Load L=12.75 Ft : R1trin= 0 LB R2min= 0 LB R1max= 1945 LB R2max= 3000 LB :JoWlfi• n> xnrotntm ,+a;rncsnro�mmx«..I.VI. -. ,tr,en1?.V.• .": Cantilever Floor Beam( AISC 9th Ed ASD ] Ver. V4020965 By: A.HELGE DORDAUBERNHOFT, , PHOENIX DESIGN & ENGINEERING Project: FUJI - Location: East Side I Beams Summary: A36 S8x18.4 x 15.75 FT Section Adequate By: 138.8% Controlling Factor: Moment of Inertia Deflections: Interior Span Live Load: Interior Span Total Load: Cant Tip 2 Live Load: Cant Tip 2 Total Load: End Reactions: Left End Total Load Reactions: R1max= 3780 LB R1min= 0 LB Right End Total Load Reactions: R2max= 7871 LB R2min= 0 LB FS= 1.5 Dead'Load Uplift F.S.: Bearing Length Bearing Length Reqd.: Bearing Length Regd.: Bearing for P on interior span: Beam Data: Span: Maximum Unbraced Span: Live Load Deflect. Criteria: Total Load Deflect. Criteria: Beam Loading: Dead Load: Beam Self Weight: Interior Span: Tributary Width: Live Load: Point Live Load: Point Dead Load: Location: Cantilever End Two: End Span: Tributary Width: Live Load: Beam Uniform Loading Summary: Interior Span: Dead Load: Interior Span: Live Load: End Two: Dead Load: End Two: Live Load: Properties for:A36 S8x18.4 Yield Stress: Depth: Web Thickness: Flange Width: Flange Thickness: Distance to Web Toe of Fillet: Moment of Inertia About X -X Axis: Section Modulus About X -X Axis (Calculated): Radius of Gyration of Compression Flange + 1/3 of Web: Design Properties per AISC Steel Construction Manual: Flange Buckling Ratio: Allowable Flange Buckling Ratio: Web Buckling Ratio: Allowable Web Buckling Ratio: Controlling Unbraced Length: Limiting Unbraced Length for Fb= .66 "Fy: Allowable Bending Stress: Web Width to Thickness Ratio: Limiting Width to Thickness Ratio for Fv=.4*Fy: Allowable Shear Stress: Design Requirements Comparison: Nominal Moment Strength: Controlling Moment: 6.317 Ft From Left Support (End 1) Critical M created by combining all dead loads and w live loads. Nominal Shear Strength: Maximum Shear: At Interior Span Edge of Right Support (End 2) Critical V created by combining all dead loads and P, w and w2 live loads. LLD= TLD= LLD2= TLD2= f.hvpaM..M.,.f; ffyrkn+nk�+w.�+ y iet on: 08 -13 -1997 0.18 IN = U860 0.21 IN = U734 -0.13 IN -0.15 IN BL1= 1.00 IN BL2= 1.00 IN BL P= 1.00 IN L= 12.75 FT Lu= 0.0 FT U 360 U 240 DL= 20 PSF BSW= 18 PLF TW= 4.0 FT LL= 125 PSF PL= 2000 LB PD= 50 LB X= 12.75 FT CS2= 3.0 FT TW2= 4.0 FT LL2= 125 PSF wD= 98 PLF wL= 500 PLF wD2= 98 PLF wL2= 500 PLF Fy= 36 KSI d= 8.00 N tw= 0.27 N bf= 4.00 N tf= 0.43 N k= 1.00 N I>x= 57.6 N4 Sxx= 14.4 N3 rt= 1.05 N FBR= 4.70 AFBR= 10.83 WBR= 29.52 AWBR= 106.67 Lb= 0.0 FT Lc= 4.223 FT Fb= 23.76 KSI h /tw= 22.1 AWSL= 63.3 Fv= 14.4 KSI Mn= 28512 FT -LB Mu= 11939 FT -LB Vn= 31219 LB V= 6076 LB Page: 2 Cantilever Floor Beam AISC 9th Ed ASD ] Ver. V4020965 By A HELGE DORDAL/BERNHOFT, PHOENIX DESIGN & ENGINEERING on 08-13-1997 Project FUJI Location East Side I Beams Moment of Inertia :': Ire q= 24 IN4 1 =. 58 IN4 jirltilever Floor Beam( AISC 9th Ed ASDJ Ver. V4020985 By A.HELGE DOU , PHOENIX DESIGN & ENGIt "RING on 08-13-1997 _ .. S8x18.4 / S Shapes / Steel Beam Project FUJI Location: East Side I Beams L =12.75 Ft •.R1 min= 0 LB R2min= 0 LB R1 max= 3780 LB ; R2max = 7871 LB 1 u CoLot< . ; r l4 -Vora s1 14- I47 . c, , '1.-.1k (�1 W 12 )(1-C1 = 7 g-5i, = rot, Fi 0, Ulu 7" - i.iIi.SL v v 0. -D F fi% 0 . . 400,L -. (4' F.sL a co 62.4< buIS 5 �i 't I 1L �, 4o '` __ d , is ' "' 0 r t = b43, 1 .. = $(53.1 4 . (€1, (Z,S) (Z�-� (i4 Zzzli 1,5e) 1eI I4.4(a l # _ x(53,`1 1,55' 14111 - � 6173.1 1 , c L2„' - " 9 %SS (K,, o d MZ s ( o 6 1 3 j _ 4 ( 10 S r 4 I s, 0-10. 5 wiLx 4-o GLtcc. � �s r� 5 C , W �d,ls (V . Z ' s ) P rain L 4 14 le_s •0 co a i0 0 E 0 ' w In 1- o 0 • 0 • ,c o c Z W 2 C.Ia het.v k- l ?“ c irsveAvoismcw.rt0yisrmrn..,1 I A -v6() T I+( 14 `17 12Ev(SLONS 1 7 - ) ( 4 0W 4- 1 /4Q (Z,,= 141s410.c0 110,1 ( 2 1 ( I . 1 - \ ' 2 1 2 + ( j � _ 7,,zt141-3,1.$) 17. .40 (-1,1.e.::)-E7i';I' ( 124e = 55;,qi, .4 4- bloc Nt 12,1zh.��( ll, IS)--�i22 141 (11.7 + s� � ��� �1 .4 ,� S' ) E t-145 -0 _ C9,�r)t vt.ke( � / , )7= 41,-in. r (ASO' "P -f 11.x (0.14s) / • 75/1 �' �i Al. o4 ,c - M t r > > 4 "O z141ZZ (' ')tt2z5t. ( ,5' 1) 7 ' ?0.4 's0)G 1 07 _ ( 8'/ w 2 . °1058 i tct.S'bl �'.�i � t i c . - X21 14 ( 1 9)0 ' ) �g� /5% 6. fig• 1erell 52.) -4I • '7z- '3 5 _l S NV 11S 1 7.1X ...19 1 /. 1S4* 14'/A017 • ro a. 0 ro • E 0 0 ,n L O a) u) a) ,n .C . o C ZW C c 13EAm 2400 ZOo) :?000 l b . Zd 7i,7,e 0 1 4 L,5 `; _._ 3,09 g1= ► alt L � GI�rGt� 1, �eA -n- sTR.els YI� 4 w !nr/ $ V'tU26 2000 # : TA1JK ADpE4), IC, 145,1 6, ` 5 : 2 ( '1, �� ) + 1$x'2 (3. `11 3115 ,12 _ 10, 427. 34 �� .O, � = I5 14 ,14 A 1o14z1,3 (7..5 = vo, aw8,z5. 10,4z?. ((0 , 1 ) 3z u (4 = V6 g 41.4 5 141 1 (1,c ;)- 2 (zl,) , 27,25-'4.85, 'f 11 1 2 2 in,.' < 51. c j �1 3 - �r� = 2v, 44 45 �c �z 1 LI , 0W p` -V '"2ZAIViNE RE.V/SION 1G vb , � �+ P v°\)1 47 M ,; tit IN 1 1 x 4-o 0 fo /fat FurI(U 2 1401 S(' C&D INTUISEct OF I (,c•AM to aEA trait. '1 't4a.44V.7.477,ainlitilS‘Winitieiii.44ionvoi3O-16,4‘....a. 13 0 0. E 0 Lo • .c o c Z LLJ t ti w .. 4o Kst, 114e 1120 •11)0 VIP t l . 4 1164• 401S 49t4,' 4151, J • _ 1 M1. m S - io `2 1 1. 1 ocii) fri c LS; 4 \1 L. IrCe.1",-14 6 • . + 1 t>2 1 ') 4 IS 3? f2 3',23I t 44. 2i4 • - ti 11 = 19,25L.C --- ?? (1.1C {r061.4(-1t7Cf)i- 10 • 4 6 001, • (1 — 2 .A 0 C 4I (10 *1 1 1 1)Z 41 ( 1°I ) -4. 71e6'.144 64 9 %,01 (4" < 1 5111(7„ 14u I x_ 4 ur C 1 , , 14.4 leci: i)vou-tcttd a 0 Q. 0 0 a 0 0 u) N • c . rn o c Z w U 1 T 0 loI,or. . CRec.K- VF iSekAA q Al ruTurr6 20-0 T4r k /A UT)E_n. Z) 4 / ?Arm!, '2 °004 ?zoo 3'o 1 3t 1 3z 135 b 'I $3z i 7.1‘ . 41' v As 4' M CJ % r .e/ cl A-u &w .y (4, Me,-7 44 ..iii ' 27. 692, 4 2 -- • 65,041 # z. L :{ o co 2., , 4Z 41, 01 w.5 51,1'11. r ; 224-10 /NC 2E V r SI ON 7 119, 3901 1$7, ) + ��3Z��'� �' 1 1832 (5') -4 837'(') 340 1,1 s , 20 , �¢ s I‘,;1s' v, 34¢ s ( - 1 , - )s ' ) - [5 oct ('1. + 1432 w 12. A40 1 . 1, I 4,, pr = 14 .4kC: x (s 21 `+ ) nr�� ADO 'F UYu g-E -- 2U" 0 d .td. TA- 1014. L P ,14 (LP @ ligEa SECT a r 304.64 e R �- s ?J INt` Retp(1.00 W-77 t%Aiv 5 w 0 ac ? 1 101 1 111 ° 300041 3.6 M� = $341. It M, M M 1V \ • 1, &) S tAcfr - Sec Ke`..: -cv to 'Aq.S 1 c d \ A- vlpu..1 14, 15(1 1 10 *M11 (1 11 (;,oi3 16,742 - " ;41.S = /0,3%. -11 � M = (z.( ) ` 20, $0,,1 I44- g341.S4 t11 42_,T1 4. 7g (4.s— 21,1R.24.1? S w 11 4 z -14 -Pv , — 14'. . Jf ' 'w 4 ii icH -ia;. r�::.4 >r�; .y9i wr,• Au'L) 10, Avb, e l " 4 6 '46'1 SIAM 3 — 5-14)11_?( 2L1 ooL 14 I11: 1 GI�Lc�� St.T euv S ►.r S , (v , �L r 4 (Ib,'1y' 63) +'81 Tut e t 34�} q�4 — lte .'. i 1%)°32.1e, S1.5 (1.1s) L3 + 1y1( V = 10, 4 5,►b 1st •< r 14.4 . NAL 1 /1d/, A -t -/99 e • 4i December 20, 1999 James Bakke 1209 South Central Kent, WA 98032 RE: Permit Status D97 -0247 770 Andover Park East Dear Mr. Bakke: In reviewing our current permit files, it appears that your permit for an interior tenant improvement issued on August 21, 1997 has not received a final inspection as of the date of this letter by the City of Tukwila Building Division. Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the building official under the provision of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, if a final inspection is not called for within ten (10) business days from the date of this letter, the Permit Center will close your file and the work completed to date will be considered non - complying and not in conformance with the Uniform Building Code and /or Mechanical Code. Please contact the Permit Center at (206)431 -3670 if you wish to schedule a final inspection. Thank you for your cooperation in this matter. Sincerely, Brenda Holt Permit Coordinator City of Tukwila John W Rants, Mayor Department of Community Development Steve Lancaster, Director ladk Xc: Permit File No. D97 -0247 Duane Griffin, Building Official 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • (206) 431-3670 • Fax (206) 431.3665 :�.::t�•F<y�i;.f'S`.'e...�''.}� _. ��,. K_, �N' i6,. c... c�fii! i�NS? �LF. zar: .c5e...'.7:uw•.nxs,- r,..�,:.... 1 02/21/1999 14:41 12536273060 City of Tukwila Building Million 6300 Southeaster Blvd. OM Tukwila, Washington 90101 RE: Fuji Try Color --Pei it # D97 -0247 Attn: Mr. Dave Larena Dear Mr. Larson : °Berabott & Associates T02 Broadway Suite 201 teems, ma, Wasbisgton 911402 February 18, 1999 dt # 23. BERNHOrT 8, ASSOCIATE �/'1 J PACE 01 I was asked by Mr. hams Bakke to reinspect the Fiji Facility on February 15, 1000, to verify the correction requested by you, have been completed. The two Iospection Reports in question; are Number 22 and Number 23. The inspection Information was gathered by Leonard Bernhoft, and was reviewed by Mr. A. Hedge Dosdal, P.E. to verify the corrections were completed to his satisfaction. The fofowiu hre kis coutsseuts to Inspection Reports: I. Nuarber 22. asks tar tlit metal sera.■ to be,BnteMad aill d area pct \e • I, 4. • ed. The column lu the on/ bar wag has been covered With Stir type x gypsum wallboard and the taped. The second floor measmine and stairway have bees 'completed. The framing for the landing was noted with 2Sd a sib Into the olds, This was done to maintain the lalegrity'Kthe onembourwall . • t ^ 'kg! ri.i4,:riNA.A )) , • • • , .02/21/1999 14: 41 12536273060 Bernhoft & Associates RE: Fiji Trn-Color FulIIyr Per 2 . 2. Nambar23.nakfocikrinifiattlakaystilhaludigalalitilliitIML This laspectioa was &Me dories the coastruction and was determined to be adequate. The laspollan ow the 1Sth of February, 19910, verified the flak training sad landinp be sad and with no bonne' when walked csa. It you have say qua's, *are meat ( 253) 274-0244. Leonard S. Bernhoft • - CC: James Bakke, lac. Fuji Try-Color King County Water Pollution Control Division Industrial Waste Program Department of Natural Resources 130 Nickerson Street, Suite 200 Seattle, WA 98109 -1658 . December 22, 1997 Mr. Bill Taylor Operations Manager Fuji TruColor 770 Andover Park East Tukwila, Washington 98188 Dear Mr. Taylor: Notification of Post - Violation Charges Dear Mr. Taylor: A grab sample collected by King County Industrial Waste at•Fuji-TruColor on October 22, 1997 (Sample site No. A8189) contained a silver concentration of 4.75 mg/1, which exceeded the permitted instantaneous maximum discharge limit of 3.0 mg/1. In response to the discharge violation Kinz County has reviewed the 14 -Day Report submitted by your company, conducted a post- violation inspection, and collected post - violation samples. g County has reviewed the data provided by Fuji TruColor and the results from our post - violation actions and has determined that due to'the satisfactory remedial actions taken by Fuji TruColor, no further enforcement actions will be taken. In response to our post - violation actions, your company is subject to post - violation charges and responsible for the cost. An itemized list of the post - violation monitoring costs is enclosed. Although this violation alone does not place Fuji TruColor in Significant Noncompliance, future violations together with this violation may do so and would result in Fuji TruColor's name being published in King County's display advertisement in The Seattle Times. If you have any questions regarding this letter, please feel free to contact me at (206) 689 -3012. Arnaud Girard Investigator Industrial Waste Program Enclosure cc: Ross Eamst, City of Tukwila GIRARD/t.BTFTC2 ( Dc1 0247 DECEIVED DEC ? 4 1997 PCWIL woR Activity POST- VIOLATION INSPECTION AND MONITORING COST RECOVERY ITEMIZATION Mr. Bill Taylor Operations Manager Fuji TruColor 770 Andover Park East Tukwila, Washington 98188 Date: 12/22/97 • Unit Number Total Item Charge of Units Charge r.w.++wa.wu.wr.wwwws ww•.. .NSw.v.M. 44.15 » . Enforcement Action Inspection $778.63 x $180.06 x Sampling, Analytical Costs and Data Analysis Metals Grab $103.71 x Metals Composite $241.97 x pH Grab $104.71 x Compliance FOG Set $256.62 x VOA Grab $220.71 x VOA Composite $316.43 x • BNA Grab $340.71 x BNA Composite $478.97 x Cyanide Grab $135.35 x Cyanide Composite $241.70 x Mercury Grab $114.71 x Mercury Composite $248.97 x BOD $267.97 x TSS $242.97 x Note: You will be sent an invoice for this amount. Girard/pvcrftc 1 1 1 $0.00 $180.06 TOTAL POST - VIOLATION CHARGES: $525.74 $103.71 $241.97 $0.00 ;1 $0.00 $0.00 $0.00 $0.00 LI,R $0.00 $0.00 • $0.00 $0.00 $0.00 $0.00 $0.00 4 4 • This procedure applies to the action it accompanies: SECTION 9 APPEAL PROCEDURE hcr -o))-11 The following provisions shall govern appeals from decisions of the director related to permits, discharge authorizations, violations and penalties under Sections 5 and 6 of this. ordinance ' A. Any person allegedly aggrieved by any such decision of the director may request that the director reconsider such decision. Such request must be made within fifteen (15) calendar days of the date of such decision. The director shall promptly issue a final decision which shall be appealable only as provided herein. B. Within fifteen (15) calendar days of the date of issuance of the director's final decision following a request for reconsideration, the person allegedly aggrieved may file a written appeal statement with the office of the zoning and subdivision examiner The appeal shall state the decision being appealed and the grounds for appeal. C. The examiner shall hear such appeal, determine whether the decision of the director was consistent with . the provisions of Section 5 or Section 6, as applicable, of the ordinance and rules and regulations promulgated by the director, and promptly issue a final decision under the provision of K. C. C. 20.24.080. D. Appeals of the examiner's final decision shall be to the Superior Court of King County or the State Pollution Control Hearings Board, as provided by law. • Note: i:iwtemp\appeal Any request for reconsideration or appeal is deemed filedyith the agency upon actual receipt of the request in our offices. This must occur within 15 calendar days as noted above. Requests for reconsideration should be sent to: A copy of the request for • reconsideration should be sent to: Nancy Hansen, Manager Water and Resources Division 700 Fifth Avenue, Suite 2200 Seattle, Washington 98104 -9830 Elsie Hulsizer Program Manager Industrial Waste Program 130 Nickerson Street Suite 200 Seattle, Washington 98109 -1658 '1Wo,1 v;, %Jib= A'iWi41 EnK.;a :s ;!:R; "LlJ5 kY4i't02i:.x�+:ud�fna�.K +,i By DRAFT Elsie J. Hulsizer Program Manager Industrial Waste Program WASTE DISCHARGE PERMIT Permit No.: 7692 Issuance Date: DRAFT Effective Date: DRAFT Expiration Date: DRAFT King County Department of Natural Resources 130 Nickerson Street, Suite 200 Seattle, Washington 98109 In Accordance with the Provisions of Chapter 90.48 RCW as Amended, Public Law 92 -500, King County Code 28.84.060 (Ordinance No. 11034), a Waste Discharge Permit is Issued to: FUJI TRUCOLOR, INC. RECEIVED Plant Location: 770 Andover Park East S E P 0 9 1997 Tukwila, Washington TUKWILA Business Hours Phone: 253 -575 -8446 PUBLIC WORKS Emergency (24 Hour) Phone: 253 -575 -8446 Mailing Address: 770 Andover Park East Tukwila, Washington 98188 Permission is hereby granted to discharge industrial wastewater from the above identified facility into the King County sewer system in accordance with the effluent limitations and monitoring requirements set forth in this permit. This permit is based on information provided in the permit application which together with the following conditions and requirements is considered part of the permit. All requirements and ordinances of King County pertaining to the discharge of wastes into the metropolitan sewer system are hereby made a condition of this permit. All discharges and activities authorized herein shall be consistent with the terms and conditions of this permit. This permit is not transferable without authorization from King County. Failure to provide advance notice of a transfer renders this waste discharge permit voidable on the date of facility transfer. TABLE OF CONTENTS S1 Emergency Contacts S2 Company Identification and Permit Summary S3 Effluent Limitations S4 Monitoring Responsibilities S5 Special Conditions /Compliance Schedule S6 Notification Requirements S7 Summary of Required Reports S8 Monitoring & Record Keeping Procedures S9 Sample Site Access and Identification S10 Operations & Maintenance S 11 General Conditions S12 Washington Department of Ecology (Ecology) Glossary King County Ordinance 11034 King County Local Limits Permit No.: 7692 Issuance Date: DRAFT Page: 2 KING COUNTY King County Industrial Waste Program (8:00 am-5:00 pm, weekdays): 206-689-3000 • Arnaud. Girard, Industrial Waste Investigator: 206-689-3012 • . Elsie J. Hulsizer, Program Manager, Industrial Waste: 206-689-3010 • King County emergency contact after 5:00 pm weekdays and on weekends is: • East Division Reclamation Plant at Renton: 206-684-2404 Sl. EMERGENCY CONTACTS If unable to reach anyone at this number call: • West Point Treatment Plant: 206-689-3801 • • WASHINGTON STATE DEPARTMENT OF ECOLOGY 24 Hour Emergency Spill Phone No.: 206-649-7000. Sample Site No. Limit Type Categorical Yes /No Description A8189 King County Local Limits No Clean -out located next to the West wall of the main processing room, 23 feet South of the door leading to the reception area Parameter Daily Average (mg /L) Instantaneous Maximum (mg /L) Maximum Loading (lb /day) Sample Type Sample Frequency Silver (Ag) 1.0 3.0 0.27 Composite Once per week pH (s. u.) Average Minimum Maximum Sample Type Sample Frequency 5.5 5.0 12.0 Grab 4 per day on days heavy metals sample is collected Daily Maximum Flow (gpd) Industrial - 32,000 Sanitary - 2,000 Total - 34,000 S2. PERMIT SUMMARY AND COMPANY IDENTIFICATION A. Summary Information Sample Site Identification /Limits /Monitoring Requirements Note: This table is only a summary of the Permittee's monitoring limitations. The Permittee is responsible for all limitations listed in Section S3. B. Reports Reports due within the first 90 days of this permit are listed below: 1. Monthly Self - Monitoring reports See S7 for report requirements and submittal timelines. C. Special Conditions There are 2 special conditions in this permit. See S5 for special conditions contained in this permit. D. Company Identification: • SIC Code No.: 7384 Hazardous Waste Generator No.: WAH000001636 Industry Type: Photofinishing Permit No.: 7692 Issuance Date: DRAFT Page: 4 Sample Site No. Limit Type Categorical Yes /No Sample Site Description A8189 King County Local Limits No Clean -out located next to the West wall of the main processing room, 23 feet South of the door leading to the reception area Parameter Daily Average (mg /L) Instantaneous Maximum (mg /L) Maximum Loading (lb/day) ( *) Arsenic (As) 1.0 4.0 ( *) Cadmium (Cd) 0.5 0.6 ( *) Chromium (Cr) 2.75 5.0 ( *) Copper (Cu) 3.0 8.0 ( *) Lead (Pb) 2.0 4.0 ( *) Mercury (Hg) 0.1 0.2 ( *) Nickel (Ni) 2.5 5.0 ( *) Silver (Ag) 1.0 3.0 0.27 Zinc (Zn) 5.0 10.0 ( *) Cyanide Total (CN) 2.0 3.0 Nonpolar FOG 100 NA pH (s. u.) Average Minimum Maximum 5.5 5.0 12.0 Discharges of more than 50 gallons per day of caustic solutions equivalent to more than 5% NaOH by weight or reater than pH 12 are prohibited. Daily Maximum Flow (gpd) Industrial - 32,000 Sanitary - 2,000 Total - 34,000 A. Effluent Limitations for: S3. EFFLUENT LIMITATIONS 1. (Federal limits are in bold face type) Permit No.: 7692 Issuance Date: DRAFT Page: 5 ( *) Listed poundage limits are for those pollutants expected to be present. Applicable poundage limit for each parameter equals the daily average concentration in mg /L, multiplied by the flow in million gallons per day, multiplied by 8.34. Violation Criteria 1. Wastewater from regulated processes shall comply with the effluent limitations prior to dilution with other wastewaters unless a fixed alternative discharge limit is approved by King County. (See Section S10.C.4 and the glossary section at the end of this document for a definition of and further information about dilution.) A review of any violation will include consideration of testing accuracy prior to enforcement action. The more restrictive limitation (concentration or mass) shall prevail for determining violations. Daily Average Limits apply to composite samples and to grab samples from short -term batch discharges. (See the glossary section for a definition of composite and grab sample.) 5. Instantaneous Maximum Limits apply to grab samples, with the exception of grab samples from short -term batch discharges. The minimum pH limit is violated whenever any single sample or any instantaneous recording is less than pH 5.0. The average pH limit is violated when a composite sample consisting of at least four consecutive samples taken at intervals of 15 minutes or greater is less than 5.5, or when any recording of 15 minutes or more averages less than 5.5. 7. The limit for nonpolar FOG (mineral origin) is violated when the arithmetic mean of the concentration of three grab samples (taken no more frequently than in five minute intervals) exceeds 100 mg /L. Limitations Applicable to All Sites 1. General Permit No.: 7692 Issuance Date: DRAFT Page: 6 The Permittee's discharge shall not interfere with the operation of the metropolitan sewer system, cause King County to exceed its NPDES permit limits, or endanger local utility or King County sewer workers. (See the glossary section for a definition of interference.) The Permitee's discharge shall not violate any discharge standard, limitation, or specific prohibition of King County Ordinance No. 11034, or local discharge limit applicable on the date of discharge. (See Section 6.D -F of Ordinance No. 11034.) Prohibitions referenced above include but are not limited to substances causing fire or explosion hazard, flow obstruction, excess oxygen demand, and toxic vapors. .. , Permit No.: 7692 Issuance Date: DRAFT Page: 7 Limitations referenced above include but are not limited to restrictions on settleable solids, organic compounds, hydrogen sulfide and polar FOG. Organic Compounds No person shall discharge any organic pollutants that result in the presence of toxic gases, vapors, or fumes within a public or private sewer or treatment works in a quantity that may cause acute worker health and safety problems. Organic pollutants subject to this restriction include, but are not limited to: Any organic compound listed in 40 CFR 433.11 (e) Total Toxic Organics (TTO) definition. Acetone, 2-butanone (MEK), 4-methyl-2-pentanone (MIBK), and . xylenes. Dischargers are required to implement good "housekeeping" and best management practices in order to prevent the discharge of a concentrated form of any of the above organic pollutants. 3. Lower Explosive Limit (LEL) At no time shall two successive readings on an explosive hazard meter at the point of discharge into the metropolitan sewer system (or at any point in the system) be more than five percent (5%) of the LEL. No single reading shall exceed ten percent (10%) of the LEL. 4. Closed Cup Flash Point Discharges shall not have a closed cup flashpoint of less than 140 Fahrenheit or 60 Centigrade using test methods specified in 40 CFR 261.21. Locator Number Limit Type Categorical Yes/No Sample Site Description A8189 King County Local Limits No Clean-out located next to the West wall of the main processing room, 23 feet South of the door leading to the rece tion area Parameters Sample Type Frequency Discharge volume See Item 2 below See Item 2 below Silver Composite (see Item 4 below) Once per week pH Grab 4 per day on days heavy metals samples are collected •, • ,• „ , • •I , • , '• • ..,.........-.44,--......-... .,.............................+;**".■....a................... . . . . • . . . . . . . . . .. . ::,.. , • . , .. ',',,, ..: , , - • , . . . . . . S4. MONITORING RESPONSIBILITIES A. Monitoring Requirements - Self-Monitoring Required 1. The Permittee shall monitor its discharges to the metropolitan sewer as specified below. The total industrial wastewater volume discharged for any processing day shall be calculated by reading the volume passing through a totalizing meter. Volume and waste type from all batch discharges shall be recorded on the self-monitoring form. 4. For self-monitoring requirements a composite sample shall be defined as consisting of at least four representative grab samples of equal volume taken throughout the processing day from a well-mixed final effluent chamber. 2. 3. Permit No.: 7692 Issuance Date: DRAFT Page: 8 ('�V't?"k5�7A;1,� ? ?�tnVe 1M9PYA•:wEY3X vM: rrt. vnwwv+x w.. n.. ar++ n:. nrw. rvoaLwwbx.. sixd+ r�,: WC.+ �n: n.. nnefn.•+. wa.. F«...... w. a...,...-: w.. ..m+m.r+e. -..+- Permit No.: 7692 Issuance Date: DRAFT Page: 9 B. Responsibility for Compliance It is the responsibility of the Permittee to insure that all effluent limitations of this permit are met whether or not self - monitoring for the parameter is required. C. Response When Violations are Detected 1. In the event self - monitoring data shows a violation the Permittee shall: a. Take immediate action to stop the violation. b. Notify King County within 24 hours of learning of the violation. 2. In the event self - monitoring data or King County monitoring data shows a violation the Permittee shall: a. Submit a written report within fourteen (14) days of learning of the violation which explains the cause of the violation and corrective actions taken to respond to the violation and insure ongoing compliance. b. Collect a sample and submit new data to King County within fourteen (14) days of becoming aware of the violation. 3. In the event the Permittee is unable to comply with any of the conditions of this permit because of a breakdown of equipment or facilities, an accident caused by human error, negligence, or any other cause, such as an act of nature, the Permittee shall: a. Take immediate action to stop, contain, and clean up the unauthorized discharges and correct the problem. b. Immediately notify King County so steps can be taken to prevent damage to the sewerage system. c. Submit a written report describing the breakdown, the actual quantity and quality of resulting waste discharged, corrective action taken, and the steps taken to prevent a recurrence. 4. Should an automatic pH recording system fail, the Permittee shall manually check the pH at least four times per hour. Any discharge without a pH record shall be considered a violation of this permit. 5. Compliance with these requirements does not relieve the Permittee from responsibility to maintain continuous compliance with the conditions of this permit or the resulting liability for failure to comply. D. Non- required Self - Monitoring All sampling data collected by the Permittee and analyzed using procedures approved by 40 CFR 136 or approved alternatives shall be submitted to King County whether required as part of this permit or done voluntarily by the Permittee. (See the glossary section for a definition of non - required self - monitoring.) S5. SPECIAL CONDITIONS/COMPLIANCE SCHEDULE Discharge of industrial wastewaters to the sanitary sewer from the Fuji TruColor facility shall • not occur until a satisfactory final site inspection has been conducted by a King County Industrial Waste Investigator. Production plans detailed in the permit application for the Fuji TruColor Tukwila facility suggest that an additional Hostert CF 70 C-41 film processor and Hostert RP 108 RA-4 paper processor will eventually be added. Thirty (30) days prior to the installation and operation of either of the two units, Fuji TruColor shall submit a report containing the following information: • Revised site plan indicating location of all added units; • Description of revised and/or new pretreatment systems to be installed in order to compensate for the additional wastestreams; and • Description of the new units' wastewater handling procedures .by identifying the maximum daily volume and type of pretreatment to be provided for each wastestream (i.e. fixer, washwater,. etc.); Permit No.: 7692 • Issuance Date: DRAFT Page: •10 S6. NOTIF CATION REQUIREMENTS Permit No.: 7692 Issuance Date: DRAFT Page: 11 A. $pills and Slug Discharges The Permittee shall notify King County immediately in the event of a spill or slug discharge to the sanitary sewer. (See the glossary section for a definition of slug discharge and Section S10.B for spill and slug discharge control procedures.) B. Changes In Discharge Characteristics The Permittee shall inform King County prior to any facility or manufacturing changes that will result in: 1. The introduction of new wastewater pollutants. 2. The significant alteration in the volume (> 20% increase from permit application) or character of the pollutants discharged to the metropolitan sewer system. 3. The discharge of wastestreams not listed in the permit application. 4. The addition of a new point of discharge or a new chemical, process, product, manufacturing line, or waste processing activity. No change shall be made until plans have been approved and either written permission or a new or modified permit has been received. In no case are any changes permitted that will cause violation of the effluent limitations specified herein. C. Hazardous Wastes Whenever the EPA publishes new RCRA rules identifying additional hazardous wastes or new characteristics of hazardous wastes, the Permittee must notify King County, EPA and Ecology if any of these wastes are discharged to the metropolitan sewer. Notification must occur within 90 days of the effective date of the published regulation. See Section S7 for reporting requirements for previously defined hazardous wastes. (See the glossary section for a definition of hazardous wastes.) D. Continuing Discharge After Permit Expiration Date This permit does not authorize discharge after its expiration date. If the Permittee wishes to continue discharge after the expiration date an application must be filed for reissuance of this permit at least 180 days prior to the expiration date. If the Permittee submits its reapplication in the time specified herein, the Permittee shall be deemed to have an effective waste discharge permit or authorization until King County issues or denies the new waste discharge permit. If the Permittee fails to file its reapplication in the time period specified herein, the Permittee will be deemed to be discharging without a discharge permit after the current permit's expiration date. S7. SUMMARY OF REQUIRED REPORTS Permit No.: 7692 Issuance Date: DRAFT Page: 12 The Permittee shall submit reports to King County as specified below. 1. ALL REQUIRED AND NON - REQUIRED (SEE SECTION S4.D) SELF - MONITORING Due Date: Report to be filed no later than the 15th day of the time period following the sample collection. (i.e. The 15th day of the following month for monthly, weekly, daily samples. The 15th day of the following quarter for quarterly samples). The Permittee shall use the King County self - monitoring form to submit results unless an alternate form is approved by King County. Content: The monthly self - monitoring reports shall contain the data 'specified in S4 or, if appropriate, a notification that no discharge has occurred. 2. SPILL, UPSET, DISCHARGE VIOLATION, OR PERMIT VIOLATION Due Date: Within fourteen (14) days after the spill notification. Content: Reason, characteristics of spill, and corrective action taken. 3. NOTIFICATION OF HAZARDOUS WASTE DISCHARGE Due Date: Within 180 days after permit issuance and with each permit renewal. Comments: Permittee, within 180 days following commencement of discharge or permit issuance, whichever is later, must notify King County, EPA and WDOE of any discharge of a listed or characteristic RCRA hazardous waste. This is a one time notification requirement. The contents of the notification may vary according to the quantity of waste discharged (see "Notification of the Discharge of Hazardous Wastes" in Section 6 of King County Ordinance 11034). See Section S6.0 for notification requirements following definition of new hazardous wastes. 4. SLUG /SPILL CONTROL PLANS, INSTALLATION /UPGRADE OF PRETREATMENT SYSTEM REPORTS, and copies of DANGEROUS WASTE REPORTS FILED WITH ECOLOGY. Due Date: As requested by King County. Comments: Slug /Spill Control Plans - King County will evaluate the Permittee every two years to determine whether they need, a plan to control slug discharges. Installation/Upgrade of Pretreatment System Reports - Per WAC 173 -240. PE report must be approved prior to installation or upgrade. • ...tf-xud.MMnYl �: v^ 4x` h! t! F^ k• M.. �k••.,-' Jas�iwt nMY'....n ^���su....wr<.esv�w. • l 1 S8. MONITORING AND RECORD KE PING Permit No.: 7692 Issuance Date: DRAFT Page: 13 A, Record Keeping and Retention The Permittee shall maintain records relating to all permitted discharges to the King County sewer system including, routine maintenance, waste disposal dates, manifests, self - monitoring reports, analytical lab results, pH monitoring records and flow records. All records required by the permit shall be available for review at reasonable times by authorized representatives of King County. Records of all such testing shall be retained for a period of three (3) years unless litigation or the direction of the Executive Director requires an extension of that time. B. Recording of Results For each measurement or sample taken to comply with this permit, the Permittee shall record the following information: 1. The date, exact place and time of sampling; 2. The dates the analyses were performed; 3. The person who performed the analyses; 4. The analytical techniques or methods used; and 5. The results of all analyses. C. Representative Sampling Samples and measurements taken to meet the requirements of this condition shall be representative of the volume and nature of the monitored discharge. D. Test Procedures All analyses shall be performed in accordance with procedures established by the Administrator of EPA pursuant to Section 304(g) of the Clean Water Act and contained in 40 CFR Part 136 and amendments thereto or with any other test procedure approved in writing by the Administrator, and /or King County. In all cases, except total dissolved sulfide, the detection limit shall be well below the discharge limit. Where 40 CFR Part 136 does not include a sampling or analytical technique for the pollutant in question, sampling and analysis shall be performed in accordance with the procedures set forth in the EPA publication entitled "Sampling and Analysis Procedures for Screening of Industrial Effluents or Priority Pollutants, April 1977" or "Standard Methods ", 1995 Edition and amendments thereto, or with any other sampling and analytical procedures approved by the Administrator. Cyanide sample collection and preservation shall follow protocol specified by King County. All self-monitoring data submitted to King County, which required a laboratory analysis, must have been performed by a laboratory accredited by Ecology for each parameter tested. This does not apply to field measurements performed`by the Permittee such as pH, temperature,, flow, atmospheric hydrogen sulfide, total dissolved sulfides, settleable solids by Imhoff cone, or process control information. Falsifying Information The act of knowingly falsifying, tampering : with, or knowingly rendering inaccurate any monitoring device, report or method required pursuant to the pretreatment standards, King County Ordinance No. 11034, or special condition of this permit shall constitute a violation of this permit, and shall be subject to the legal remedies available under "Revocation of Permit or Authorization" and "Penalties and. Enforcements" in Section 6 of King County Ordinance No. 11034. Toxicity Testing In the event King County is required by the Department of Ecology to determine the source of a pattern of acute toxicity pursuant to its Treatment Plant NPDES permit, the Permittee may be required to test its effluent for toxicity according to procedures to be determined by King County. Signatory Requirements for Industrial_User Reports Any report required by this permit shall meet the signatory and certification requirements listed in Section 3, "Definitions" and Section 6, "Waste. Analysis Reporting Requirements" of King County Ordinance No. 11034. Permit No.: 7692 Issuance Date: DRAFT Page: 15 >9. SAMPLE SITE ACCESS AND IDENTIFICATION Unobstructed access to sample sites shall be available to authorized King County personnel during normal operating hours. The Permittee shall be responsible for providing alternate sample sites in the event of obstruction of . access or upon evidence of tampering with the monitoring equipment. The Permittee shall allow King County to permanently label the sample sites used to collect wastewater samples. The Permittee shall at all reasonable times, allow authorized representatives of King County to enter, inspect, and sample as specified in Section 6:L- of County Ordinance No. 11034. S10. OPERATIONS AND MAINTENANCE Permit No.: 7692 Issuance Date: DRAFT Page: 16 The Permittee shall use waste preventative practices to reduce or eliminate contaminant loading to the metropolitan sewer system. These practices shall include proper chemical storage, spill prevention and notification, and maintenance and operation �f any required pretreatment equipment. A. Chemical Storage Chemical solutions, solid chemicals, waste materials, oils and solvents shall be stored in a manner that will prevent the entry of these materials into the metropolitan sewer system. 1. Non - compatible chemicals shall be segregated and securely stored in separate containment areas that prevent mixing of incompatible or reactive materials. 2. The Permittee shall install shut -off devices to all drains in any hazardous waste storage areas. 3. Chemicals shall be dispensed only in roofed and bermed areas that eliminate potential spills to the metropolitan sewer system. 4. All empty barrels which have not been cleaned (steam - cleaned or triple rinsed) shall be adequately stoppered and stored in an upright position. 5. Process tanks shall be located in a bermed, roofed, secured area capable of containing 110 percent of the volume of the largest tank. The Permittee shall insure that process solutions are used and stored in such a manner as to minimize spills of concentrated solutions to the sanitary sewer. B. Spill or Slug Discharge Control Procedures (See Section S6.A) 1. In the event of a concentrated solution spill such as a tank failure, the Permittee shall not discharge any spilled solution to the metropolitan sewer system unless laboratory test results indicate that the substance meets the conditions of this permit and the Permittee receives approval from the King County Industrial Waste Unit. 2. Concentrated waste or spilled chemicals which do not meet, or are not treated to meet, the discharge conditions of this permit shall be transported offsite for disposal at a facility approved by the Department of Ecology or appropriate County Health Department. 3. The Permittee shall maintain and inspect all process solution tanks on a regular basis. Any leaks shall be repaired promptly. 4. The Permittee shall use spill prevention practices to preclude the discharge of liquids, solids, or gases, which by reason of their nature or ,,,a, ,4 <c um l:AwYnnih w..la Permit No.: 7692 Issuance Date: DRAFT Page: 17 quantity are, or may be, sufficient either alone or by interaction with other substances to cause fire or explosion. 5. All process tanks and chemical storage containers shall be accurately labeled. Emergency phone numbers of King County, Fire Departments, your company's 24 -hour corporate contact and WDOE shall be posted at all sites that King County requires. 6. The Permittee shall insure that concentrated wastes from process tank filters and other equipment is prevented from entering the sanitary sewer unless it is treated to meet the discharge conditions of this permit. 7. The Permittee shall maintain and use product recovery options such as drag -out rinses for each plating bath or process as required to meet the discharge conditions of this permit. Recovered materials shall not be discharged to the sanitary sewer unless they are treated to meet the discharge conditions of this permit. C. Pretreatment Equipment Maintenance and Operations 1. All pretreatment systems used to bring the Permittee's discharge into compliance with King County's discharge limitations shall be maintained continuously in satisfactory and effective operations by the Permittee at his expense, and shall be subject to periodic inspections by authorized King County personnel. These systems shall be attended at all times during discharge to the metropolitan sewer system. In the event that such equipment fails, the Permittee must notify King County immediately and take spill prevention precautions. 2. The Permittee shall not initiate construction or modification of a pretreatment system prior to receiving King County approval of plans and specifications per WAC 173 -240. In addition, King County may require an engineering report and an operations and maintenance manual. 3. King County shall be contacted before the beginning of any limited experimental modifications or new equipment testing that could reasonably be expected to affect effluent quality or quantity. This experimental work shall proceed only after securing written approval from King County and following the Permittee's adherence to any applicable special conditions. 4. The effluent limitations specified in this permit are to be met by treatment of the wastes for pollutant removal. The use of metropolitan water, ground water, seawater, storm water or other materials, including waste products, for the purpose of diluting a waste to achieve those limitations is prohibited. 5. The Permittee shall adequately maintain and efficiently operate all treatment or control facilities or systems installed or used by the Permittee to achieve compliance with the terms and conditions of this permit. Permit No.: 7692 Issuance Date: DRAFT Page: 18 •'• . • , D. Water/Sewer Meter Requirements 1. The Permittee shall obtain or maintain access to a water or sewer meter which can provide accurate information regarding industrial process wastewater and cooling water discharge to the sewer. Another method of volume determination may be used only upon approval by King County. The Permittee shall cease discharge whenever a King County representative requires, or an effluent check shows a pH violation (as defined in "Violations," Section 6.N.3.c of King County Ordinance No 11034). No discharge shall be resumed until the effluent is neutralized to an acceptable level. Solid Waste The Permittee shall handle and dispose of all solid waste material (as defined in WAC 173-304-100) not otherwise authorized by this permit, in such a manner as to prevent their entry into the metropolitan sewer sYstem. All covers, screening devices, sumps, hoppers, conveyors and other facilities provided for the recovery and handling of solid wastes are to be maintained in an efficient operating condition. G. Storm Water/Cooling Water 1. Storm water, surface water, ground water and roof runoff shall be excluded, except where specifically authorized by this permit or King County Ordinance No. 11034, from the metropolitan sewer system. r.,. :i';ti.,�:. �:� ✓!. tun. atstNwir.+'. nr.:. w. r. o...,.. �+. w............ ww... a. .r.w...u..dr,..avr,e....�.eu.w. Use. q.; r�¢ t.. ax' an. w. m.:. row ww... w�. v.. r.... rr.+. �• ww. e. ,.rrww.t- s�n•...�.r...,.,...... S11. GENERAL CO I ITIONS Permit No.: 7692 Issuance Date: DRAFT Page: 19 A. The discharge of any pollutant more frequently than, or at a level in excess of, that identified and authorized by this permit shall constitute a violation of the terms and conditions of this permit. Whenever the Permittee refuses to take corrective action or continues the violating condition, the imposition of civil penalties including fines for each violation and /or termination of this permit may result. Termination of this permit may require disposal of the industrial waste in some manner other than into the public sewer, private sewer, or side sewer tributary to the metropolitan sewer system at the expense of the person holding the permit. Any person causing damage to a public sewer or treatment facility by discharges in violation of the terms and conditions of this permit, shall be liable for any such damage, incurred by King County as a result of such damage or discharge. B. The diversion or bypass of any discharge from any pretreatment facility utilized by the Permittee to maintain compliance with the terms of this permit is prohibited except where unavoidable to prevent loss of life or severe property . damage. The procedure outlined in Section S4.C. shall be followed in case of such a diversion or bypass. C. After notice and opportunity for a hearing, this permit may be modified, suspended, or revoked in whole or in part during its terms for those causes cited in Section 6.J.8 or Section 6.J.9 of King County Ordinance No. 11034. D. If a toxic standard or prohibition (including any schedule of compliance specified in such effluent standard or prohibition) is established under Section 307 (a) of the Federal Clean Water Act for a toxic pollutant which is present in the discharge authorized herein, and such standard or prohibition is more stringent than any limitation upon such pollutant in this permit, this permit will be revised or modified in accordance with the toxic effluent standard or prohibition and the Permittee shall be so notified. Section 307 (a) requires that the Administrator of the Environmental Protection Agency shall promulgate effluent standards (or prohibitions) for toxic pollutants which he or she has listed as such. E. Nothing in this permit shall be construed as excusing the Permittee from compliance with any applicable federal, state, or local statutes, ordinances, or regulations. F. All requirements and ordinances of the Environmental Protection Agency and the Department of Ecology pgrtaining to hazardous and toxic wastes, disposal facilities, and discharge of wastes into the metropolitan sewer system, are hereby made a condition of this permit. Permit No.: 7692 Issuance Date: DRAFT Page: 20 S12. WASHINGTON DEPARTMENT OF ECOLOGY CONDITIONS GIRARD /PERFTC This permit does not constitute authority for discharge into waters of the state. Any such discharge is subject to enforcement action by the Department of Ecology. Upon issuance of this permit, the Permittee assumes the responsibility to abide by the following environmental requirements, and any other appropriate regulations stipulated by the Department of Ecology. The Department of Ecology retains authority to enforce these permit conditions (RCW 70.105 and RCW 90.48). Conditions To Protect Ground and Surface Waters 1. Contaminated waters or wastes shall not be discharged to state waters. 2. Boiler blow down and water shall not be discharged to state waters. 3. Solid chemicals, chemical solutions, waste materials, oils and solvents shall be stored in a manner which will prevent the entry of these materials into state ground or surface waters, and in a manner that will prevent spillage by overfilling, tipping or rupture. 4. The Permittee shall handle and dispose of all solid waste material in such a manner as to not cause any adverse effect on ground or surface water quality. 5. Filtered solids or sludge shall be stored in such a manner that drainage from this material is prevented from either draining across public rights - of -way or entering the local storm drain system or the ground water. 6. No emulsifiers or dispersants are to be used on waters of the state without approval from the Department of Ecology. 7. If corrosive processing solutions are used, the processing /plating floor shall be sealed with corrosion resistant material which prevents leakage. This coating shall be repaired or replaced as needed. Questions regarding the implementation of conditions outlined in Section S12 should be directed to the regulatory authority, the Washington State Department of Ecology, at (206) 649 -7000 (Northwest Regional Office, 3190 160th Avenue SE, Bellevue, Washington 98008 - 5452). King County Water and Land Resources Division. Industrial Waste Section Department of Natural Resou EMS 130 Nickerson Street, Suite 200 Seattle, WA 98109-1658 (206) 689-3000 September 8, 1997 CERTIFIED MAIL RETURN RECEIPT REQUESTED Mr. Ross Earnst Director of Public Works City of Tukwila 6300 Southcenter Boulevard Tukwila, Washington 98188 Draft of Permit No, 7692 Dear Mr. Earnst: Enclosed is a draft of the proposed Industrial Waste Discharge Permit No. 7692 for the photoprocessing operation located at 770 Andover Park East, Tukwila, Washington. This draft permit is for permit within permit fee has een pal., a public notice publication. If you have any questions you ma Arnaud J. Girard Investigator Industrial Waste Program Enclosure GIRARD\ Drarrc r , ° RECEWED 99 TuKwu PUBLIC W01-11% eview. Please notify this office of any comments about the draft f your receipt of this letter. If no comment is received and the igned permit will be issued thirty (30) days following the final date of ontact me at 689-3012. 05/97 King County Water and Land Resources Division Industrial Waste Section Department of Natural Resources 130 Nickerson Street, Suite 200 Seattle, WA 98109-1658. (206) 689 -3000 September 8, 1997 CERTIFIED MAIL RETURN RECEIPT REQUESTED Mr. Bill Taylor Operations Manager Fuji TruColor, Inc. 770 Andover Park East Tukwila, Washington 98188 Draft of Permit No. 7692 Dear Mr. Taylor: Enclosed is a draft of the proposed Industrial Waste Discharge Permit No. 7692 for the photoprocessing operation located at 770 Andover Park East, Tukwila, Washington. This draft permit is for your review. Please notify this office of any comments about the draft permit within fourteen (14) days of your receipt of this letter. If no comment is received and the permit fee has been paid, a signed permit will be issued thirty (30) days following the final date of public notice publication. If you have any questions you may contact me at 689 -3012. Ve t _ ours, Arnaud J. Girard Investigator Industrial Waste Program Enclosure cc: Ross Earnst, City of Tukwila (letter only) Doug Hilderbrand, King County (letter only) Jim Newton, Fuji TruColor • GIRARD\DPLFTC .11/Ate ; r! ?is4iC> e�Lr?; c: ,'•,'t$; :S��.h. Permit Fact Sheet Fuji TruColor Page 2 #nPr.4 ?5!7, Special Comments: Fuji TruColor is a new photoprocessing facility located in Tukwila, Washington. An application for this facility was received on July 23, 1997. The permittee had requested that authorization to discharge to the sewer be granted prior to the State's required 60 days holding period (RCW 90.48.170). The permittee was instructed to discuss the matter with Department of Ecology representatives. Mr. Doug Knutson, Dept. of Ecology, called our office on September 4, 1997 to discuss the matter. Mr. Knutson stated that the purpose of the rule was to provide ample time for both the State and the public to review and comment on the proposed action and that the timeline was meant to be flexible. Provided that public comment period requirements were followed, Mr. Knutson stated that he had no objections to allow Fuji TruColor to be allowed to discharge prior to the 60 days holding period. A letter from Mr. Knutson explaining Ecology's interpretation of the rule was requested. Industrial discharge to the sewer from the Fuji TruColor - Tukwila facility will consist of wastes originating from mini labs and paper and film processing. The various waste streams generated from these processes will be handled according to their silver content. Pretreatment systems provided for silver removal consist of electrolytic silver recovery systems and several sets of two chemical recovery cartridges (CRC) operated in series. The waste streams and their level of treatment can be summarized as follows: No Treatment - Directly discharge to sewer via sample site • Developer (from film processor /paper processor /mini lab) •• Bleach (from film processor /paper processor) • Non metal bearing washwaters (from film processor /paper processor) • Stop bath (from paper processor) • Stabilizer (from film processor) Electrolytic Recovery Systems • Fixer (from film processor /paper processor) • Fixer / fixer bleach (from mini labs) There are two electrolytic recovery systems. A small unit will handle the fixer and fixer /bleach solution from the mini labs and the larger one will process the fixer solution from the film processor and paper processor. The fixer will be continuously routed through the electrolytic systems in a closed loop process. As the fixer solution is replenished, an overflow from the electrolytic system will occur into an equalization tank for further treatment via CRCs Chemical recovery cartridges (CRC) • Fixer and fixer /leach overflow from Electrolytic recovery systems • Low flow washwaters following fixer tanks (from film processor /paper processor) Wastes to be treated by the CRCs will be accumulated in an equalization tank prior to being pumped through one of the several sets of two CRCs operated in series. In its permit application, the permittee has proposed future installation of an additional film and paper processing units. Special conditions regarding requirements associated with the proposed additions were included in the permit's Special Conditions/ Compliance Schedule section (S5). • Discharge volume - Daily / water meter reading Silver (Ag) - Weekly / Composite sample pH - 4/day on days silver samples are collected • The pH of the discharge is not expected to be a problem as caustic and acidic waste streams should self-neutralize. The permittee has demonstrated through historical data from similar Fuji TruColor facilities that the discharge's pH will be maintained within the permitted range. • ' • • , „ • . , Permit Fact Sheet Fuji TruColor Page 3 ' The following self-monitoring requirements are proposed in this draft permit: Cleaning agents used at the facility will not contain cyanide or dichromate as is sometimes seen in photoprocessing facilities. The permittee will therefore not be required to self-monitor for cyanide and 'chrome. • • .•.. . " , , City of Tukwila Department of Public Works TO: Permit Center FROM: Public Works Engineering DATE: August 21, 1997 SUBJECT: Fuji Tru-Color 770 Andover Park East Project No.: PRE97-013 Permit No.: D97-0247 Contact Person: Jim Bakke Phone: (253) 854-5527 THE FOLLOWING PUBLIC WORKS PERMITS HAVE BEEN APPROVED FOR ISSUANCE IN ACCORDANCE WITH THE PLANS APPROVED ON AUGUST 21, 1997: Storm Drainage NOTIFICATION OF UTILITY PERMIT ACTION Two copies of the confirmed Utility Permit Application and plans are attached for inclusion in the permit file. JJS/sal CF: Development File (with copy of application and plans) PW Utilities Inspector (with copy of application and plans) • PERMIT FEE $25.00 TOTAL: $25.00 John W. Rants, Mayor Ross A. Earnst, P. E., Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: (206) 433-0179 • Fax (206) 431-3665 Bldg: CITY OF TUKWILA Department of Community Development Building Division - Permit Center 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431 -3670 PROJECT NAME: . 1 ) . ) 1 "Mu CDC f PROJECT ADDRESS: 110 A tJDOUER ?ARK EAI4t REVISION SUBMITTAL DATE: - Is . le m1 PLAN CHECK/PERMIT NUMBER: t ?i " 0Z47 CONTACT PERSON: J 1 M BA-1' IE PHONE: 2a• O4. 5sZ7 REVISION SUMMARY: Goetacc.,-tiorQs K FuSL'e WooIaS LE-r-rw $ 1111 f utt.O1 Nc: Dom". 8 . S 119 SHEET NUMBER(S) Co PL€TE Set "Cloud" or highlight all areas of revisions and date revisions. Planning Fire RECEIVED CITY OF TUKWILA PERMIT CENTER SUBMITTED TO: CITY USE ONLY Public Works 3/19/96 13 -97. 04:54P From D Lisa 47f0 Alvarado Canyon none' An I )Iego, California !W I:'(1 FAX 619 286 6723 . 1i19 286 0500 � I FUJI TruColor August 13, 1997 Ms. Joanna Spencer City of Tukwila Department of Public Works 6300 Southcenter Boulevard, Suite #100 Tukwila, WA 98188 Original: 1 Class Mail Fax Copy: 206- 431 -3665 Dear Ms. Spencer. 619 . 87 3005 'P.01 RECEIVED AUG 14 1997 P uB LI W Leonard Bemhoft of Bemhoft & Associates has asked Fuji TruColor, Inc. to provide this letter, per his conversation with you on Tuesday, August 12, 1997. Fuji TruColor, Inc. agrees not to discharge any industrial waste into the King County Metro sewer system until the Industrial Waste Permit has been approved. Fuji TruColor, Inc. also agrees to continue the industrial waste collection from the film and paper processing equipment and to continue to have an approved hazardous waste collection firm properly dispose of the effluent. We appreciate your assistance in expediting the building permit process. and Vic - resident, Operations Western Region cc: Leonard Bernhoft, Bemhoft & Associates Jim Bakke, James E. Bakke, Inc. Sheryl Casady, Manager, Fuji TruColor, Inc. - Tukwila Ken Wilson, Tech. Services Mgr., Fuji TruColor, Inc. - Tukwila Jim Newton, Environmental Mgr,, Fuji TruColor, Inc. August 8, 1997 Dear Mr. Bakke: ue Mr. James Bakke . 1209 South Central Kent, Washington 98032 City of Tukwila Department of Community Development Steve Lancaster, Director SUBJECT: CORRECTION LETTER #1 Development Permit Application Number D97 -0247 Fuji Tru Color 770 Andover Pk E This letter is to inform you of corrections that must be addressed before your application for development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed review comments from the Building Division and Public Works Department. At this time the Planning Division and the Fire Department have no comments regarding your application for permit. The City requires that four (4) complete sets of revised plans be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a Revision Sheet must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions please contact me at the City of Tukwila Permit Center at (206) 431 -3672. Since e , �����I i,92 a49 ,6 Kelcie J. Peterson Permit Coordinator Enclosures File: D97 -0247 ffP .i,'± C+fftMe;tx►;.lrxHS»'�t'3s V.03chexxea:wMtrCwx1o.t r 4twn kt.11,teh John W. Rants, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • (206) 431-3670 • Fax (206) 4313665 TUKWILA BUILDING DIVISION PLAN REVIEW COMMENTS DATE: August 5, 1997 PROJECT NAME: Fuji Trucolor tenant improvement PLAN CHECK NO.:' D97 -0247 Plan Reviewer: Contact Bob Benedicto at (206) 431 -3670, if you have any questions regarding the following comments: 1. The processing plant area is to be served by no less than two exits. Although the space plan indicates three potential egress routes from this area the two egress routes through the office area are not in compliance with code requirements. Specifically, both routes require egress through more than one adjoining or intervening room. In addition, both include egress through corridors that are also not in compliance with code requirements. Re: UBC 1003.1, 1003.5, 1004.2, 1005.1(paragraph 2). Please review space plan and revise as necessary. 2. The H -7 occupancy (upper and lower level) must comply with the detailed exiting requirements for "H" occupancies. UBC Section 1018. 3. Additional information is required for the roof framing plans shown on sheet #3. Provide typical wall partition detail or otherwise note the intended construction. Information should include the proposed height, size and spacing of wood studs; proposed method for anchorage of sill plate to floor slab; and proposed deck, ceiling, and wall materials. Note: Wood studs must comply with Table 23- I -R -3. Exceptions to Table 23 -I -R -3 will require analysis to justify. 4. Re: Roof framing noted in comment #3: Provide design detail for the method of anchoring ledger to existing concrete wall. 5. Section "A -A" on sheet #6 has call -outs for mezzanine framing that are not consistent with the mezzanine framing plan. Please clarify. 6. Structural calculation indicates analysis of several mezzanine floor beams of the same size ( S8x18.4 x 12/67') . Specifically they are listed as beams # 1 through #5 and have variable loading. Provide a key plan to coordinate the location of the referenced beams and source of the concentrated loading. 7. Note the applicable requirements for special inspection per Chapter 17. 8. Provide detailed information on the plans to show compliance with the envelope requirements of the Washington State Nonresidential Energy Code. C City of Tukwila Department of Public Works 4) Show the North arrow on sheet 4 of 4. PUBLIC WORKS DEPARTMENT COMMENTS „ , n*V,..,.,::. DATE: August 7, 1997 PROJECT NAME: Fuji Tru -Color PLAN CHECK NO.: D97 -0247 PLAN REVIEWER: Contact Joanna Spencer at (206) 433 -0179, if you have any questions regarding the following comments. John W. Rants, Mayor Ross A. Earnst, P. E., Director 1) Sheet 1 of 1- Label the size of the existing 2" water meter on the plan and show the existing water main. Plan shows the water main over the storm sewer line, which is incorrect. 2) Where is section 1/2 called out on sheet 2 of 2 and El sheet 1 of 2 shown? 3) Cross - reference trench details shown on sheet 4 of 4eet 2 of 2 and on El sheet 1 of 2. 5) Provide an Industrial Waste Permit for discharge to the sanitary sewer from King County Metro Industrial Waste Division. For this permit, you will need to contact Arnauld Girard at (206) 689 -3012. 6) Submit a Metro Business Declaration. 7) Provide an emergency oil /water separator for the parking lot drainage system. 8) Existing single detector check valve inside the fire vault shall be replaced with a Washington State Health Department approved double detector check valve assembly. 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: (206) 433.0179 • Fax (206) 4313665 Awoken &Asssciatss 702 Broadway, Suite 102 Tacoma, WA 98402 Phone 274 -0244 Fax 627 -3060 August 15, 1997 City of Tukwilla Tukwila Building Division Bob Benedicto, Plan Reviewer Re: Plan Review Comments Dated: August 5, 1997 Project Name: Fuji TruColor tenant improvement Plan Check No: D97 -0247 Comment: 1) The processing plant area is to be served by no less than two exits. Although the space plan indicates three potential egress routes from this area the two egress routes through the office areas are not in compliance with code requirements, Specifically, both routes require egress through more than one adjoining or intervening room, In addition, both include egress through corridors that are also not in compliance with code requirements,Re: UBC 1003.1, 1003.5, 1004.2, 1005.1 (paragraph 2). Please review space plan and revise as necessary. Response: A 1 hr exit corridor was added between the restrooms and lunchroom to the entrance foyer. All doors in schedule marked as min, 20 min. assemblies and existing windows changed to 45 min. assemblies. Comment: 2) The H -7 occupancy (upper and lower level) must comply with the detailed existing requirements for "H" occupancies, UBC Section 1018. Response: I hr exit corridor w /stairs from mezzanine to chem. mix level & exit door from chem. mix level into corridor. Doors in schedule marked as 1 hr assemblies Comment: 3) Additional information is required for the roof framing plans shown on sheet #3. Provide typical wall partition detail or otherwise note the intended construction. Information should include the proposed height, size and spacing of wood studs; proposed method for anchorage of sill plate to floor slab; and proposed deck, ceiling and wall materials. Note: Wood studs must comply with Table 23- I -R -3. Exceptions to Table 23 -I -R -3 will require analysis to justify. RECEIVED CITY OF TUKWILA PERMIT CENTER Response: Additional details & cross - section provided. Walls to be blocked @ 10' Comment: 4) Re: Roof framing noted in comment #3: Provide design detail for the method of anchoring ledger to existing concrete wall. Response: Detail shown as #3 on sheet 3 of 7. Comment: 5) Section "A -A" on sheet #6 has call -outs for mezzanine framing that are not consistent with the mezzanine framing plan. Please clarify. Response: Mezzanine revised for exiting requirement and this corrected. Comment: 6) Structural calculation indicated analysis of several mezzanine floor beams of the same size (s8 x 18.4 x12/67'). Specifically they are listed as beams #1 through #5 and have variable loading. Provide a key plan to coordinate the location of the referenced beams and source of the concentrated loading. Response: Key plan shown on drawing 6 of 7 and also in structural calculations. Comment: 7) Note the applicable requirements for special inspection per Chapter 17. Response: Special inspection note on sheet 5 of 7. Special inspection for welding & structural bolting. Comment: 8) Provide detailed information on the plans to show compliance with the envelope requirements of the Washington State Nonresidential Energy Code. Response: Envelope requirements provided on sht. 7 of 7 component calculations provided, shts 1/3 to 3/3 erely, nard Bernhoft Bernhoft & Associates L A-v-f,dyt GIRARD ATCFTC Enclosure , . ' "• • . .• ".„:, • . • . . • • • • • •• • • Mr. Ross Earnst Director of Public Works City of Tukwila 6300 Southcenter Boulevard Tukwila, Washington 98188 Sincerely, I / 14 Arnaud J. Girard l.• Investigator Industrial Waste Program King County Water and Land Resources Division Industrial Waste Section Department of Natural Resources 130 Nickerson Street, Suite 200 Seattle, WA 98109-1658 (206) 689-3000 July 24, 1997 CERTIFIED MAIL RETURN RECEIPT REQUESTED •JUL 2 g 1997 ' • 71.1KINI l iVORK.F.; Permit Application for Fuji TruColor Dear Mr. Earnst: We have received the attached waste discharge permit application from Fuji TruColor located at 770 Andover Park East, Tukwila, Washington. I will determine what type of discharge authorization will be necessary for this operation and inform you of my decision. If a permit is required, I will send you a copy of the draft permit for your review and comment. If you have any comments regarding the attached application, please contact me at 689-3012 within fourteen (14) days of receipt of this letter. Thank you for your assistance. Dear Sir: City of Tukwila Fire Department Fire Department Review Control #D97 -0247 (511) Re: Fuji Trucolor - 770 Andover Park East July 24, 1997 The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. Areas or rooms where use, dispensing or handling of hazardous materials takes place shall comply with Uniform Fire Code article 80, section 8004. 2. The total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 3000 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 10B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (NFPA 10, 3 -1.1) Portable fire extinguishers shall be securely installed on the hanger or in the bracket supplied, placed in cabinets or wall recesses. The hanger or bracket shall be securely and properly anchored to the mounting surface in accordance with the manufacturer's instructions. The extinguisher shall be installed so that the top of the extinguisher is not more than 5 feet above the floor and the clearance between the bottom of the extinguisher and the floor shall not be less than 4 inches. Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be identified with a sign stating, "Fire Extinguisher ", with an arrow pointing to the unit. (NFPA 10, 1 -6.3) (UFC Standard 10 -1) John W. Rants, Mayor Thomas P. Keefe, Fire Chief Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 5754439 City of Tukwila Fire Department Page number 2 Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5) Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. (NFPA 10, 4 -3, 4 -4 and 4 -4.3) Every six years, dry chemical and halon type fire extinguishers shall be emptied and subjected to the applicable recharge procedures. (NFPA 10, 4 -4.1) If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10A -4 -4) 3. No point in a sprinklered building may be more than 200 feet from an exit, measured along the path of travel. (UBC 1003.4) Aisles leading to required exits shall be provided from all portions of buildings. Aisles located within an accessible route of travel shall also comply with the Building Code requirements for accessibility. (UFC 1204.1) 4. Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 1207.3) Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. Exit hardware and marking shall meet the requirements John W. Rants, Mayor Thomas P. Keefe, Fire Chief Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 5754439 City of Tukwila Fire Department Page number 3 of the Uniform Fire Code. (UFC 1207.1- 1212.8) 5. When two or more exits from a story are required, exit signs shall be installed at the required exits and where otherwise necessary to clearly indicate the direction of egress. (UBC 1013.1) When two or more exits from a story are required and when two or more exits from a room or an area are required by U.B.C. Section 3303, exit signs shall be illuminated. (UBC 1013.3) 6. Maintain sprinkler coverage per N.F.P.A. 13. Addition /relocation of walls, closets or partitions may require relocating and /or adding sprinkler heads. Sprinkler protection shall be extended to all areas where required, including all enclosed areas, below obstructions and under overhangs greater than four feet wide. (NFPA 13 -4- 4.1.3.2.1) 7. All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recognized by The City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1742) All sprinkler system plans, calculations and the contractors Materials and Test Certificates submitted to The Tukwila Fire Prevention Bureau must be stamped with the appropriate level of competency seal. (WAC 212 -80) 8. Maintain hose station coverage per City Ordinance #1742 and N.F.P.A. 14. Addition /relocation of walls or John W. Rants, Mayor Thomas P. Keefe, Fire Chief Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206) 575-4439 Page number City of Tukwila Fire Department partitions may require relocating and /or adding hose stations. An approved hose station requires plans review. (Plans must be submitted to the Fire Marshal for approval prior to installation.) (City Ordinance #1742) 9. All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 10. When walls and ceilings are required to be of fire resistive or noncombustible construction, interior finish materials shall meet the requirements of Uniform Building Code 803. The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 8 -B of The Uniform Building Code. (UBC 804.1) Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1742) This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. John W. Rants, Mayor Thomas P. Keefe, Fire Chief Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206) 575-4439 e Tukwila Fire Prevention Bureau John W. Rants, Mayor Thomas P. Keefe, Fire Chief Headquarters Station; 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206) 575-4439 Mr. Bob Benidicto, Senior Plans Examiner c/o City of Tukwila Building Department 6300 Southcenter Blvd. Tukwila, Washington 98188 RE: Tenant Improvement Permit Fuji TruColor, Inc. 770 Andover Park East Dear Mr. Benidicto Fuji TruColor, Inc. will be filing a request to provide Alternate Methods of compliance with the intent of the hazardous materials storage section, ( in regards to the secondary containment overflow requirements for irritant materials) of the 1994 Uniform Fire Code. This request for approval to use Alternate Methods will be in accordance with Section 103.1.2 of the code. We are also requesting that certain items be accepted at a different date to allow us to get this project into the review process. Work under separate permits : Bernhoft & Associates 702 Broadway Suite 102 Tacoma, Washington 98402 July 18, 1997 1. Mechanical plans will be submitted under separate permit application. All duct work to be sized and installed in accordance with the 1994 UMC Chapter 10 Section 1001 thru 1009 and Table 10 -A thru 10 -F. Equipment sized and ductwork to be insulated in accordance with the 1995 Washington State Non - Residential Energy Code (NREC) All quantities for ventilation and make -up air in accordance with the 1995 Washington State Ventilation and Air Quality Code (VIAQC), Chapter 51 -13 W.A.C. Gas piping sized and installed per the 1994 UMC Chapter 22. Support all piping per Table 22 -A. Structural Calculations will be provided and stamped by Washington State Licensed Structural Engineer for HVAC equipment on roof. Insulation and roof plan will be submitted in _accor,dance with the; 1995 Washington State Non- Residential'.Energy Code (NREC')"'along With the ` - .. Mezzanine. details and framing layout to. be submitted :by,: steel fabricator. and calculations ;provided by`.a Washington State. Licensed Structural Engineer We appreciate your assistance, and the cooperation that u.: have._exte:nded .torus on this project: Leonard , S." Bernhoft. 1 1 BUILDING DATA : Allowable PS.C.MPArit. LAP.AL project Napp: FUJI TRUCOLOR INC. project_ Owners: FUJI TRUCOLOR, INC. 770 Andover Park East Tukwila, Washington 98188 (206) 575-8446 Parcel Number: 262304-9095 Site Address: 770 Andover Park East Code:. 1994 UBC., 1991 UPC, 1994 UFC., 1994 UMC., 1995 WSEC 1995 VIAQ Zoning: Commercial Buijj Occupency_L B: Offices. F-1: Factories (Photographic) S-1: Storage (Moderate Hazard) H-7: Occupancies having quantities in excess of of Table 3-E that are area health hazard. Iyj Qcjq Type V-N ; w/ automatic sprinkler system 41,loweble Squgre:Footage:. Table 5-B; B,S-1, F-1, and H-7 Occupancy and Type V-N Construction = 8,000 SF. Building is divided by an area separation wall at the center of the building. qqqth 11411 of tzqklglina 2 Side Separation @ 50 % .50x 8000 = 4000 SF + 8000 SF = 12,000 SF Automatic Sprinkler System increase is three times the accumulated total, which equals 12,000 x 3 is 36,000 SF . Total area of South half of building is 35,575 SF which is less than 36,000 SF. Use: Storage 3813 SF 0 1/300 SF 13 Office 2152 SF @ 1/100 SF 22 Manuf. 12937 SF 0 1/200 SF 65 Total Occupant Load 100 Fire Resistance of Exterior Walls: Table 5-A . B, F-1, and S-1 ,type V-N construction less ,"•, " , - than 20'. from property line requires *Hour wall•' • - - .Openings not permitted less protected less than:10:feet, " • . : All property lines a distance greater than 20 feet in area of this project.. cP.PAII.P.Y.5.@P@T@IO.D.W411AF Table 3 - 8 None required for B to F-1 separation. None required for B to S-1 separation . One hour required for H-7 to S-1 separation One hour required for F-1 to H-7 separation . One hour required for B to H-7 separation . Note that all openings in one hour separation walls to be protected with one hour fire rated assemblies. I ) Crow Water— A Sound Invxstmine annfilimmo AFRICA:4T 9LtWYS! WW1: FUJI T ruCol or , In . ADD 'r Or STS DMICHARDND WAYTEWATStt: 770 Angs v er 'A r K at^ n _ BUSINESS MAILING ADORE& 7 7 0 X 1411 1 & P k ray► ► 7 .•r •t`rrlr w o 901110 �s w . Wit. yr &uu , - - -- C(tX !} Cox r........ QM CO Cede .. _......._ PIERSON TO 911 CONTACTS!: 4JOUT lire APlt tGTiON: 24 Maur rovag.ncy Sh„r 1 Ca Y YsYphon,e No. (20d —) ?Hone No (Z91—) 5 77 5 6 .r. AilLga ±n_na aria{ ' �� `_ _. Novi lilts kaElaaLi. TruCr.1t r r Tnc_ 77[1 onri�QMrz.. ,.,• 4s 7ti c l-Ua W 9Ala_ sew Mdrew Cal% ZOOM . .......+ i .,a �.. 01/03/1994 22:23 2068545441 07/18/1997 '11:09 9214476 FJJI You will find detailed instructions for completing each section vi this epplikation and asch requited tsthibtt in the mimed packet, 'Westover Discharge Permit Application and Exhibits »Instruetlons and Cuidelitw.' Review the entire application and instruction packet Carefully before completing any part of the application. ■ Submit out appllades for each site. III Answer all wielder's and laclude the required exhibits. ineomplete applications will be nrhuned to you. >♦ U you do not have an annum for the requested btforteation, tadiutt to and explain why, • Indicate "NA" U s section doer not apply to your opendoes. • Use additional paper, U needed. S No application fee is required. You will be billed a permit fee dl a peaalt It panted ▪ Send five capital of the completed application and odubib for 1. NATURE OF BUSINESS • 8r+efly dacHbe the main activities at the applieent site (type of tmtasty(t urhtp, service, nemadiation). Wholesale photofinishing laboratory Permit required due to pretreatment of wastewater to meet King County Code with regard to silver. 2. PERRNENT IDENTIFICATION NUMBERS AND PikMITS Starld.ld Indwatrlal C7amJtmtlarl (SIC) 7 3 8 9 ¥PA WAD Na Watsinow.t Ammo No, rm..n1 Aiw.. v...0h u.• IHM11 ee btarteo as woo o11.. ;+r i, y u t ru_ra a.rlt.l nu envteonetenrol Control rainier booed for Applioint Jilt. PAGE 03 ° AvE 03 1 Kit g t;olstty poignant 01 Me1►op•Itt.n $ervMee IMeete+ tntaowelet we.a deedon 130 Nteke.eetl nook $t tie 300 Seems, MIaWwo+an 0e10e•1e6e SECTION A— BUSINESS NAMES AND ADDRESSES SECTION 8—GENERAL BUSINESS INFORMATION 11Wdnew ACDVity T Type of ,'vein, at Iiwtd Nana D Daly Quarlida Monte M Maodalwn Processing color fi11r. C Color ne•atives 5 5,500 1 12 500 Process�+- ing + Color prints 4 40,000 9 90,000 +ecrrolo. w w r v��r - -.�...I.n..► . .at�r 4 CL. Dami Chow Ds r U%II %I 14 rtovta Plo of Maws No o RenployounkUt Po / Y Y i s t I ► 4 0 1 =r G I E D v N Maximum lead Last♦• Chs.*cal eo MOW Na.. Porpw Dolly Qssatttko rook 'foram f a l l Velum. Comma. kneel/ Ilaaillrun wall IisWs• Negecolor LA dolor Negative Develo.er Film Develo - Develo• 0 e :ma•e 30 65 98.7 8.9;1 ultra Negacolor Color Negative oxidize Clemente Aq Bleach III Film Bleach to Silver Halide 50 , 115 148 22:1 • .. M q ., .,.. . N UL M901 VPI r' 1 se an tlrNU OW LR Fixer Film Fixer Silver Halide 15 30 14$ 2.511 EC Nayacolor Co or Negative Stabilize Dye :rage ULF Stabilizer Film Stabilizer and Aid Even Dri.nq 65 150 1. 48.1 �1QCii EC LA 100 Color Paper Developer Developer Develop Dye Im *9e 75 165 288 .3.3;1 Acetic Acid Nord Stop Bath Kim D yy elpnment 210 4 107 00:1 Colorprint - Color Paper ' oxidise El emental Ag ' ' . r. i1 t v ►lids ° 'R x'16 a,1 colorprint Color Paper Solu411ze and 'emove RA Fixer Fixes Silver Halide ` 65 y 140 28f Si] r9V1 A11fq t:encrnitazrvna Tre axvre - ' • aw a1.r o rat.lal al wataf ea cnemic i i -- 01/03/1934 22:23 20E0545441 �7i�lOi I 11:VV ti :1441* i ✓ .v. 'Arlie: 'r s".• t • .. • I+YiML.tl7 .:.5,x I. L)AILY AND if1AiONAL VAWIA11GN>f i. RAW MAYORAL* AND CHEMICALS t1aCIA IN 11IG 1r110CW; fasAnvotir Disc1 iuga Permit rippMatAvri • •• 1;'.l •`.:......04.'4) ■ N..i:4, JK1/4. 1 Wlv L. — NnJUUL 1 ANU utZt.HH'I *These figures are estimates based on an average of 50 and a maximum of 75 ep.loyees . Employees have staggered reportinar.imPs - not 3 q }, i f t a 2. 1USINES3 ACTIWO AND PRODUCT, Burman activities include both manufacturing and rtmadi ehbn actfolelN. concont according to Men fecturer'e mixing inatructlonv. litmwripso PAGE 04 rolls sq ft lead Last♦• Chs.*cal eo MOW Na.. Porpw Dolly Qssatttko rook 'foram f a l l Velum. Comma. kneel/ Ilaaillrun wall IisWs• Negecolor LA dolor Negative Develo.er Film Develo - Develo• 0 e :ma•e 30 65 98.7 8.9;1 ultra Negacolor Color Negative oxidize Clemente Aq Bleach III Film Bleach to Silver Halide 50 , 115 148 22:1 • .. M q ., .,.. . N UL M901 VPI r' 1 se an tlrNU OW LR Fixer Film Fixer Silver Halide 15 30 14$ 2.511 EC Nayacolor Co or Negative Stabilize Dye :rage ULF Stabilizer Film Stabilizer and Aid Even Dri.nq 65 150 1. 48.1 �1QCii EC LA 100 Color Paper Developer Developer Develop Dye Im *9e 75 165 288 .3.3;1 Acetic Acid Nord Stop Bath Kim D yy elpnment 210 4 107 00:1 Colorprint - Color Paper ' oxidise El emental Ag ' ' . r. i1 t v ►lids ° 'R x'16 a,1 colorprint Color Paper Solu411ze and 'emove RA Fixer Fixes Silver Halide ` 65 y 140 28f Si] r9V1 A11fq t:encrnitazrvna Tre axvre - ' • aw a1.r o rat.lal al wataf ea cnemic i i -- 01/03/1934 22:23 20E0545441 �7i�lOi I 11:VV ti :1441* i ✓ .v. 'Arlie: 'r s".• t • .. • I+YiML.tl7 .:.5,x I. L)AILY AND if1AiONAL VAWIA11GN>f i. RAW MAYORAL* AND CHEMICALS t1aCIA IN 11IG 1r110CW; fasAnvotir Disc1 iuga Permit rippMatAvri • •• 1;'.l •`.:......04.'4) ■ N..i:4, JK1/4. 1 Wlv L. — NnJUUL 1 ANU utZt.HH'I *These figures are estimates based on an average of 50 and a maximum of 75 ep.loyees . Employees have staggered reportinar.imPs - not 3 q }, i f t a 2. 1USINES3 ACTIWO AND PRODUCT, Burman activities include both manufacturing and rtmadi ehbn actfolelN. concont according to Men fecturer'e mixing inatructlonv. litmwripso PAGE 04 rolls sq ft 01/03/1934 22:23 20E0545441 �7i�lOi I 11:VV ti :1441* i ✓ .v. 'Arlie: 'r s".• t • .. • I+YiML.tl7 .:.5,x I. L)AILY AND if1AiONAL VAWIA11GN>f i. RAW MAYORAL* AND CHEMICALS t1aCIA IN 11IG 1r110CW; fasAnvotir Disc1 iuga Permit rippMatAvri • •• 1;'.l •`.:......04.'4) ■ N..i:4, JK1/4. 1 Wlv L. — NnJUUL 1 ANU utZt.HH'I *These figures are estimates based on an average of 50 and a maximum of 75 ep.loyees . Employees have staggered reportinar.imPs - not 3 q }, i f t a 2. 1USINES3 ACTIWO AND PRODUCT, Burman activities include both manufacturing and rtmadi ehbn actfolelN. concont according to Men fecturer'e mixing inatructlonv. litmwripso PAGE 04 rolls sq ft ofmosimitailigiall Paper procel,sin -p IIIIIIIIIIIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIIIIIIIII Idwarcal Drcaugui a S,w4: FREGIMMA11111111118,900 lyrics! h+ensM Freguanyy (2) Daly de Shipped to Refiner. Monthly WA ". A 4,800 2,470 6 , 710 NM MEM end 11• 1.4401rl a Enter mrnlel, monthly, or daily nohow -or 4plumre of eadt removal (1) Ewing twig dosaiption old lair is mim er for.th imam Also floe thou nvmkr, MEMO*, A /Ill 7w4;.. *, - •r7..:A lea,.. (.1 ..rw.iw' '4ly .Rw'l.n.1l,l .9.1.M re.0.0.14, n. Obi 0~4 ww,1.l1.d.rir.1 i. 01/03/1994 22:23 n71 11.05 5.1 2068545441 4. INDUSTRIAL WASTEWATERS DISCHARGED TO METRO SEWERS t. r*0r001p P I*AT1ON OP d11CMAg011 WntPrwit r. nlrel.,, ,'. Pm-v le a nnlfrntinn r .�� PAGE 05 r�+aC n� *Typical values for effluents from similar operations is presented in Exhibit D. �• ■SY1p ANp /6YO0p NIMOVfp 1V MIAMI 0714111 THAN M/7RO 1NV1R1 1.0, 10no 4 memo JtI. JUN l.- 4'H000l. Nrvu utb .HHN I wN (contmucu) ai at Electrolytic flake silver Shipped to Refiner. Monthly 100 lb• Metallic replacement Shipped to refiner Monthly 1,800 lb a Enter mrnlel, monthly, or daily nohow -or 4plumre of eadt removal 01/03/1994 22:23 n71 11.05 5.1 2068545441 4. INDUSTRIAL WASTEWATERS DISCHARGED TO METRO SEWERS t. r*0r001p P I*AT1ON OP d11CMAg011 WntPrwit r. nlrel.,, ,'. Pm-v le a nnlfrntinn r .�� PAGE 05 r�+aC n� *Typical values for effluents from similar operations is presented in Exhibit D. �• ■SY1p ANp /6YO0p NIMOVfp 1V MIAMI 0714111 THAN M/7RO 1NV1R1 1.0, 10no 4 memo JtI. JUN l.- 4'H000l. Nrvu utb .HHN I wN (contmucu) ai at T'pr of Cortrwnption /Dbdt rpa %ow !Jar MinorDU4Aagportaw *owes; (t) alum tyOi 1400711M0 ptwwri OIM wis Ames. rva.a N4 c..v..r) Hochman %oilman to dtarteial precooks' w.mMaw•nMr p a 13,750 31,250 a o a 13,7sU 31,350 Calla 000ji. water NA 0 0 NA 0 0 Norte "tact O Ui g wow NA NA 0 0 0 NA 0 0 0 !Boiler aid milli tone tyad/►Itnadown 0 NA 0 Wow tiootporsnd Inr prodwtt Ni, 0 . 0 NA 0 0 !{weary wiaar /•w•a1wr.l+r .Z —. 1,250 . ' . 'Pint „ — a 1, 2 3 0 1. 0 0 0 Senn carter Idw•te: wJr it dintarle a is a a arosi .....) - ' • NA 0 . 0 NA 0 0 AIM, I,NU1.we UMW / WIIIMMIIIIIIII a 10 u •BO u 100 300 ass briplon NA 0 0 • NA 0 0 tanpaneon teA riA NA NA 0 • 0 adwr NA 0 0 4 NA 0 r..�.....,....�► 0 . _ _.,.. TO7iA6.7 • t'" ■ 13,130 33,L30 NA 15,150 53,530 (3) CM" OW OPPvrnlaar ii . *w MS saw &ewer N. C1tp Swig b. hive!. Well a Reddened Water &!taw Materials e. Stem Mtn L Crowd Water (2) Emir Oa "Imprint twrar fer the dlacM:e point: a. Sever b. Sbonu Man e Readying Watee d. Waste Healer. e. Evaporation I. Pevdtad (1(Uw diaclMCiy ii mitring Om NvOsis, also indlaw AI nab arms, (al manikin if avaiiaLLJ ..... - ..,... «... a..•+.- ..- , +cM nt: . Y+ of .Yi.'Httv,':ctl...'x�.Y' ✓.st�W 01/03/1994 22:23 2068545441 07/18/1997 11:09 S214476 V VV.. i....• ....•. r'• rv..w.. .v. N.•. ...h ..,••.Ih ..I /f 0.. n ( I 1. REQUIRED IXHIM' VOMIT L DOCUMWTATION OE WA7'!at DALANC>c CALCULATIONS. !. WATER WANGS SECTION 0 —WATER BALANCE V .4 orb ttrntOMPnesA PAGE 06 P4St 06 • 01/03/1994 22:23 07/18/1997 11:09 SECTION E-- REWUIRED EXHIBITS I. REQUIRED EXHIBIT Ai Dana ' St =MT G va inn D: EMOU1rr lb Doom Pr DOQSrT G. maim it OCHIIT• L• EXHIBITS James U. Newton Primed Nano 2068545441 9214476 SCOW= now DIAGRAM SITE LAYOUT PANNED MANGLE IN PRETREATMENT OR WASTR DISPOSAL PRACTICES ANALYTICAL OR HISTORICAL DATA SPILL PR*VENTION AND CONTAINMENT PLAN TANK CAFACTI'IU AND CONCENTRATIONS NYDROG><OLOGIC REPORTS FOR GROUND WATER IIIN DIATION ENGINEERING REPORT 1Regxir.d only iS you have waatewiibtr pretreatmsslt systems of are intending N WWI such ayeteene•N DOCUMEN OP WATT/ NALANCI CALCULATIONS Z. OPTIONAL EXHIBIT =MT j: HYDROGEOLOGIC RH'ORTS FOR LONGTERM GROUND WATER IMMOLATION. T artily under penalty ul law ui.i 1144r .1.;...w4s..d 0'4%4 all .itesl.a anon •+w per rend under awp dM.Nen e/ surcaviaten in usvroance with . sy.owi dallaeoomi ►v rims...• dr• W+l1r Raw. and w..i sIs 1i►a L.l.rw.Wf.. submitted. Based on any inquiry of the person or persona who manage the eyatsuh, or those meows directly ;wErse !• (or $etha.ing th• Wo.v.atten, the i:+tortn *tlon tubvt tt!d 1* in the but n►F my knowledge and bale, true ammo, and complete. i am aware that there ur significant ptnaltisa for subohittrtg false information, including the poaumWty of line and impr{sonatent for knowing violations. Wastewa0rr Discharge Permit Application F JJI Natl,onal r:nvlronmenzal, manager Two Li � /F9y PAGE 07 °A3E 07 a . SECTION F CERTIFICATION allernernao 08/21/1997 17:08 206862487.4 THIS CERTIFIES THAT THE PERSON NAMED HEREON IS REGISTERED AS PROVIDED BY LAW AS A • PACIFIC CONCRETE DEPARTMENT OF LABOR AND INDUSTRIES t L F Gc.1 23b ' DEPARTMENT OF LABOR AND INDUSTRIES THIS CERTIFIES THAT THE PERSON NAMED HEREON IS REGISTERED AS PROVIDED BY LAIN AS A r e�, • ..r +g 61S7 c •' . ,,,} }., �ii►T ;•'r ',i X1 4 \:`..W' i• : rrl �I''' Ja➢•XR •,. �,C }r�.;�Yi,:ir. • i;:.i 'L� " E�t ` '.1,IC•I %�'Y�:..n�•'t;t�'. STATE OF WASHINGTON STATE OF WASHINGTON PAGE 01 1.025-052-00013-921 . 12 • •t . ' : � ^ T ; s�i; alr3 '••.:' 'tY'#'.•,; `' . *+ �3 08/21/1997 17:08 206862487.4 THIS CERTIFIES THAT THE PERSON NAMED HEREON IS REGISTERED AS PROVIDED BY LAW AS A • PACIFIC CONCRETE DEPARTMENT OF LABOR AND INDUSTRIES t L F Gc.1 23b ' DEPARTMENT OF LABOR AND INDUSTRIES THIS CERTIFIES THAT THE PERSON NAMED HEREON IS REGISTERED AS PROVIDED BY LAIN AS A r e�, • ..r +g 61S7 c •' . ,,,} }., �ii►T ;•'r ',i X1 4 \:`..W' i• : rrl �I''' Ja➢•XR •,. �,C }r�.;�Yi,:ir. • i;:.i 'L� " E�t ` '.1,IC•I %�'Y�:..n�•'t;t�'. STATE OF WASHINGTON STATE OF WASHINGTON PAGE 01 1.025-052-00013-921 drawn .y JRS C ec .y LSB sca e dote •. S -14 -91 . iscip lne Job number 91 -F4 Sheet Number II' -il' 96'-S• 2 FUJI TruColor ?l0 ANDOVER PARK EAST FLOOR PLAN SCALE I/8• = I` 2ND FLOOR PLAN' uCALE V8• = I' 1171E G8• l.IC ROOM . MO® CA8■CAI. PFIIJIPUE 1S Opi5TR1.1GTED 1 MR oclaPA•GY �ARAnoN W A i RATED AV@8Y 20 wsexs . T.2• 19 TREADS . 10• Ml® Cu*+IGai MFTfaN�tF H-T OLGRANGY _ 1000 6ALSIWUTANT MFD1W11� FLOOR IS OPEN sRnnRH, raEr AREA > - row oPER I u x 9' ALLE55 LADDB2 < FALL FROTECnon cA6> =. FAll PRarrxnoR CASE TO START AT A 1EISHi of H' CITY OF TOFWO 1 APPROVED AUG 2 1 1997 03 nASA LU;LC'5,0 Di1 ^; ivy RECEIVED CITY OF TUKWIL4 PERMIT CENTER REVISION PER BUILDING SEPT. LETTER S 5 -91 PER PUBLIC WORKS LETTER S - -17 L client FUJI TruGolor 770 ANDOVER PARK E. TUKWILA, WASHINGTON Project FUJI TruGolor 770 ANDOVER PARK E. TUKWiLA, WASH. Sheet Description FLOOR PLAN Commercial and II' -il' 96'-S• TUKWILA, WASHINGTON T NOR �-1 U3• i VS ?D'6• 5'JY• 5' -2' i 9p'-b r - •/SIN ..� 9 AIASE 340J i 1 I pp RDOM = --. RIR CMP. O f b _ W " _ ® REGEPiION/FOT'ER N6 9c1 PT � O OFFICE - I = •- D A I c ` - � - � I i--- � � COMPRESSOR AIR COMP. AIR DRYR E ROOM RECEIVER ® � _ cw�1 ' � O � _ D m �_ z N 1 J - -- p0 � --pper� v�D ADD n L 1 z n� p @� ®3P IFGPEGTION � Imo- +V 6 y R(�L ?F,FSR PROC�CS'.�OK 7 ® gq77 � - _ -- un So � n n n O;', W4tD =m.MH • H4 v2• I I oo�r colatmoR 20 hma �. I �.. p t GA�AI% � 22: 81G • � A _ � L- J • I i � —_ i = c X 4pC/P4�A.ACINEa e5 ❑ 140K 11 � i m f INSPELTIOF! cAT aS40.m a Q.G. 6 p .,5, L • F " " IRO �RCALL PAc- I S� &DS , _ BFI AT Q! V2 oo FILM LiRER ! DARY QOM gg�I ��TI I o _ O3 F OFFICE In sc+ Fr oar cawrmore ' 1 N& 7 � p�pp 9 MA NTENP OM (a) �oeH Doo25 NGE G T.RLm OPi 2HH 5a Fr Iwwi o � - �" `'AF 1 0 _ - � _ b W �/ _ II I -•- P#' PRIG1g9 I I • - 1p ., :I PRU 59115 PL T AR f I FRIGIN6 ARID SHIPPING AREA ❑ I FILM GII T t j AIR GONDITIONED / IEAATID 5PACE {4l1BO0 } zl LL .00M <4o Sn Fr I � F, r0 ! EX75T. SAN SEY'ER (__ `—TEST 4 PORT " -p � z i N I SEYER � STREET/ 1 C d � b-4• - G � � { SYNTRA 1 350 ( I:iEP SYHif�A 350 eO11CFQ � NoYGHIN6 �--, '.li07fiiald6 �—, SORT rn r �(� V H ® OFFICE I56 sa FT o c_ Ib Sam ELECTRIC 4.AYQUT Ed„h•>91T - ■ _ _ ■ � d ' r iI-' GE T® T�II u I �� ' ��3 � ppp, � p� SYN1RA SPLICER _ . ° RYkfRA -�- -- 5 RISERS s T.2• a mFfvs . lo• 01� NTRA PRINTINe 9 SYNTRA PRINTING ',4 R (. l � I '' I I 2pH 600A ]OO ibw Irz• T' Ir i 1? SEC.TRIG P J 2T4 I-1 FIRE ASSEMBLY Lll'>E 2" DIPu � k F F �} g C �I L S 7 L I I � I L®T ° U PR= I@Ca"'Fb7TG'65` SPLICER SP4 - IGESL ° O Q I�. ® 19 TREADS a 10" o tz� �I I i `�T a z c2 & 0.RTAp 51oEO vatr. uPr OPPOWE 1EGEI V1N6 � 5 350 li g s•s=• PN9.ET 4•. 4• PA -9 ■ r•■ ■�0 snag mBom _ p lO -± °. - _ � � r E � � I� L 9 C: x L 3 �c Lr^ L C R�7r C y 5NIPPINB sw• SRIGERL1cmL pAY1[mi T 5P v �'.. t ' % ` G.O. . L I I F r 6 fifi -t s y . its �ez � � cr o Exn n MA6 �/ lyv CO 1 � � �� wAV1 »� T� d e� GF!£MM H -7 � FLOOR . IX ROOM OGGUPANGYS ■ surm i � ' 1400 GAL. � _ - REGE uuucD 14 " ',�, _ �£- 9 >< 12 OPErM GRTAN OH SIDE L — _ "s�• 4 �'_ I _/ TES WATER GORtIZOLS G.O . rJJ NO ifA7 � I e e ��� i ., g / j ,� I I' ! • • I ■ of � 1 1 �_ j1' I� g N: , [ �' t, 7 9-n �1 � a a � I I I I ► - LocAnor+ (Y m TRUCK BAYS o `r 8 FO 1:1 b I I �b-' I V O pu n b � b I I b II Ib' se'a- '.EAT SF'AGE ■ t RKKS AHOvE �L — _ AT DOOR x a o y� Y b 5T0'FL46E O I IP/ FX FIX LOOP 22o vAO I Ho aw n HRG FX FIX�LOOP 22o vAc 3o Ar+P n - a � 5-7 OGGSI P. P S-1 oGG9Y- p �OOO sS CONTROL A F 1 !'. h i m TT Fa44E •iR PX.OIPfdIC! 513 sRAV�i�APJp !ki OFHiiCS Alg PRDSTL"P� ; W A niR F#€ RATLJ A55E`ElY Ia _ ' O � // 1 � x �� b TftFrD� R15Ht5 29 . 1• a 5 . 10' _ . sTORA� RACITU 1 1 � a . H I SOUT 104'5' 5' -1• 20 wsexs . Ta 19 -b1 TREADS. 10' 9 'H • 20' -II' 92'9• 24'3' �' 212• -b• FUJI TruColor ?l0 ANDOVER PARK EAST FLOOR PLAN SCALE I/8• = I` 2ND FLOOR PLAN' uCALE V8• = I' 1171E G8• l.IC ROOM . MO® CA8■CAI. PFIIJIPUE 1S Opi5TR1.1GTED 1 MR oclaPA•GY �ARAnoN W A i RATED AV@8Y 20 wsexs . T.2• 19 TREADS . 10• Ml® Cu*+IGai MFTfaN�tF H-T OLGRANGY _ 1000 6ALSIWUTANT MFD1W11� FLOOR IS OPEN sRnnRH, raEr AREA > - row oPER I u x 9' ALLE55 LADDB2 < FALL FROTECnon cA6> =. FAll PRarrxnoR CASE TO START AT A 1EISHi of H' CITY OF TOFWO 1 APPROVED AUG 2 1 1997 03 nASA LU;LC'5,0 Di1 ^; ivy RECEIVED CITY OF TUKWIL4 PERMIT CENTER REVISION PER BUILDING SEPT. LETTER S 5 -91 PER PUBLIC WORKS LETTER S - -17 L client FUJI TruGolor 770 ANDOVER PARK E. TUKWILA, WASHINGTON Project FUJI TruGolor 770 ANDOVER PARK E. TUKWiLA, WASH. Sheet Description FLOOR PLAN Commercial and drawn by , -IRS check by LSB scale date AS SHOWN 8 -13 -91 discipline job number 1l -F4 Sheet Number ('oz SCALE 3/8" = I' 2x12DF #2 JOISTS o l6" O.G. 5/5" GWB TYPE "X" 2 x 12 PRESSURE TREATED LEDGER 0 HALL „ DETAIL T I 0 O S 11_ Lu OL u 1 - O I6d NAILS a 8” O.G. INTO BEAM I6d NAILS 8" O.G. f 5 I/8" x 33" GWB 2 x b PLATE -2x6 STUDS 16" O.G. (l) IOd NAILS 2x6 STUDS lb" O.G. 12' STUDS I/4" x 3" RAML DRIVE PINS @ 24" O.G. EXISTING b" GONG. WALL 2 x 12 DF #2 LEDGER 1 JOIST HANGERS #1-11212 RAWL PINS 1/4" x 3" e 32" O.G. 2 X 6 P.T. PLATE GONG. SLAB HALL DETAIL @ FULL HEIGHT WALL 2 x 4 FRAMED- - WALL q' WALL HEIGHT 2x8DF #2 a Ib" O.G. 6x8DF #I HEADERS SCALE I/4" = I' 2 x b STUD WALL 2 x b FRAMED WALL b x 8 DF #I HEADERS ® DOORS 20' - 10" 2 x 8 LEDGER VI/SIMPSON LU28 HANGERS 16'-II" 4 MAINTENANCE ' Q.G. SECTION q WA HEIGHT - 1 11 i (1) IOd NAILS ROOF FRAMINS PLAN SIMPSON LFTA W/ 16 -IOd SPACE ANCHOR a STAGGER SIDES SCALE 1/4' = I' •—DBL. PLATE e BREAK EXIST. WALL VI/METAL 5TU05 ROOF FRAMINS PLAN HATER HEATER ROOM AE FUJI TruGo Ior 770 ANDOVER PARK EAST TUKWILA, WASHINGTON 1 NOTE: CEILING JOIST NOT DESIGNED FOR STORAGE ABOVE TOTAL DESIGN LIVE LOAD DEAD LOAD IS 55 PSF ' x8DF #I — HEADERS a DOORS • TYP. U.O.N. EXIST. COL. JOISTS: 2 x 12 DF #2 a IS" O.G. TYP. 2 x 12 DF #2 LEDGER VI/SIMPSON JOIST HANGERS #141.1212 DARK ROOM - PAPER PROCESSORS O (-2x 12 RIM JOIST 2 x 12 PF11 RIM JOIST rM,+O +r.+ +WN+rr + +O + +O N+N+M R-40 BATT INSMATIOIi-' T FOIL' SYSTEM 2x12.16' V4' DIA x 3• RAH_ PINS • 32' O. r 2 x 6 PRESSURE TREAIED PLATE N x 6 DEL TOP PLATEN-5i' 648 TYfE 2 x 6 BLOCK-INS 5 /5' 648 TYPE'X' ! 2 x 6 STUDS 16 00. TOP PECK TO BE 12 ° -0° FROM 2 x 6 510 HALL GONG_ FLOOR NOTE: CEILING JOIST NOT DESIGNED ROOF FRAMING PLAN .FOR STORAGE ABOVE TOTAL DESIGN LIVE LOAD DARK ROOM - FILM PROCESSORS DEAD LOAD IS 55 PEE SSE L4• =4' 4x16 PIIIZ6"I :fWA rrrr+•rf • +. u+a�i��ri +i +i+i+I AMA Vi!ti+i NO Ex(STTNS 6 314'x 40 I/2 6Y8 SO ,°D EL AST IS 2 x 12 LEDGER e PARTITION 5 V2' GONG_ st,� F�osnwG 2 x b FRAMED HALL STUDS ® lb" O.G. 6 x8DF #I HEADERS JOISTS: 2 x 12 ® 16" O.G. TYP. 1 6 x 8 DF #I I y — HEADERS— ® DOORS PIPE CHASE 6-4" 5 /b' 6143 TYPE•X' BOTH 512E5 51NPSON HANGER H1212 5/9 6h6 T1'PE•X'� 2 x 6 STUD HALL 14' -2" EXISTING 5 I /8 ° x 33° 6K13 SCALE 1/4" = I' 2 x 12 DF #2 LEDGER -- VI/SIMPSON JOIST 1 HANGERS #HU212 —j EXIST. COL. 6 x 8 DF #I HEADERS SECTION R - 01 15 N EXIST. GOL. CO Of TUK4WIL1 APPROVED AUG 2;1997 AS rOOD CU!LD1 G �,VmOIa RECE{dEO CITY OF TUKW.ILA PERMIT CENTER qAI I4IO ?ER RN DC-pt. I t1E(Z S client FUJI TruOolor 110 ANDOVER PARK E. TUKWILA, WASHINGTON Pro)ec FUJI TruGolor 0 ANDOVER PARK E. TUKWILA, HASH. Sheet Description ROOF FRAMING PLANS DARK ROOMS HATER HEATER ROOM drawn by -IRS check by 4 -_,f_ 7 LSB scale date AS SHOWN 8 -12 -91 discipline job number 91 -F4 Sheet Number 4 4 -_,f_ 7 L x ELEV. 98.00 e9FINISH FLOOR 100.00 ASSUMED 56'-1 1/2" SLOPE L=> SLOPE SAW Of; LINE TYPICAL 54' -1 i/2" L 770 ANDOVER PARK EAST TUKWILA, WASHINGTON 28' -3 1/2° ELEV. 91.43 ELEV. 47.40 FUJI TruGolor SLOPE " 28' -3 I/2" ELEV. 9651 N s J 5 -10 3/4" ELEV. 91.19 —ELEV. 9'7.13 \— SAM CUT LfE TYPICAL DRY TRENCH COVER PLATE SEC T1OY S 2' x 3' TYPICAL 23'-4° ELEV. ab2S — ti ELEV. 98.43 b° TRENCH F1 ter. 9850 le-5 i /4" 4" PYC� ELEV. 98.43 b" ASSUMED ELEV. EXIST. FINISH FLOOR ® 100.00 2 "x 2 -112 "x 1/4" ANGLE W/ NELSON STUDS 24" O_G_ DEPTH VARIES SEE TRENCH PLAN FOR ELEV. I I/2 "x 11/2"x 1/4 ANGLE 14/ SPOT WELD 0 12" O.G. 10." TRENCH t ELEV. 9850 b" TREND SCALE 3/16• = 1' C DRY TRENCH SCALE 3/4" = I' ELEV. 94.28. e SUMP in N ELEV. DRY TRENCH FOR UTILITIES 2 "x 2 -I /2 "x 1/4" ANGLE W/ 1/2" DIA. NELSON STUDS 0 24" O.G. SUMP 11/4" MGNICHOLS GO. TRENCH GRATING 1'1/ 1/4" DIAMOND PLATE SOLID COVERED AREAS 5 -1/2" EXIST. GONG. SLAB #4 DOWELS INTO EXIST. 5 -1/2" FLOOR SLAB @ 3" O.G. 6" MIN. EMBED. BARS 12" O.G. #4 BARS CONTINUOUS @ 12" O.G. SOLID COVER OVER DRY TRENCH: 11/4" McNIGHOLS GO. TRENCH GRATING NI 1/4" DIAMOND PLATE ® SOLO GOVERED AREAS O DETAIL - TRENCH COVER SCALE 3" = I' ELEV. 44.33 ELEV. 92.83 CITY OF TUKWI1A APPR0 /00 AUG 2 1 19G7 AJ rOLU FU1LDO.0 DR: , 731 , N RECEI4 CITY OF TUKWILA PERMIT CENTER ISSV I4I ON PE1- 1'JEL16 WORK(-7 • 1 ' client FUJI TruGo 110 ANDOVER PARK E. TUKWILA, WASHINGTON Project FUJI TruGolor 170 ANDOVER PARK E. TUKWILA, WASH. Sheet Description TRENCH DETAILS DOOR SCHEDULE DOOR # TYPE SIZE MATERIAL JAMB SILL FIRE HARDIVLARE REMARKS discipline SOLID CORE 3068 13/4' WOOD 4 3/4"511.--2 PC WA N/A WOMEN N08 2 SOLID CORE 3068 1 3/4' WOOD 4 3/4•1L -2 PC WA N/A MENS •109 3 SOLID CORE 3068 i 3/4' Tiocts r 3F4517--2 PC WA WA LUNCH RM'IIO 4 SOLID CARE 3068 13/4' WOOD 14 3/4• 7L -2 PC WA WA CI LUN.1 1‘11 110 VERT LFT OH DOOR 9 x 12 SECT METAL 1 RECEIVING 4 SHIPPING 1 VERT LFT 014 DOOR 8 x 10 SECT_ j TTAL I HR STORAGE AREA 8 HOLLOW METAL/LIGHT TIGHT 60168 PETAL c. 3 /45TL -1 HR DOOR SWEEP 1 HR CLOSURE WEATHER STRIP MAG. ROOM 9 I4OLLOW PETAL 6068 METAL 6 3/451L -1 HR DOOR SLEEP I HR CLOSURE CHEM. MIX ROOM 10 HOLLOW METAL 3068 METAA' 3;45T°.-.. —III° I CLOSURE WATER HEATER ROOM It HOLLOW METAL 3 8 METAL 3/4'S1L -1 HR • 482 CLOSURE CHEM. MIX ROOM 12 SOLID CORE 3068 13/4' WOOD 3/4 $TL- -2 PC WA STORAGE UNDER STAIRS 13 SOLID CORE 3068 1314 WOOD 3/451L -2 PC WA STAIRWAY /CHEM. MIX ROOM 14 SOLID CORE/LIGHT TIGHT 3068 1 3/4' WOOD F. 31451L -2 PC DOOR SWEEP WA WEATHER STRIP MAGROOM 15 SOLID CORE/LIGHT TIGHT 3068 1 3/4' WOOD 16 3/45TL. 2 PC DOOR SWEEP WA WEATER STRIP FILM PROCESSOR DARK ROOM 16 SOLID CORE/LIGHT TIGHT 3068 1 3/4" WOOD E. 3/451L -2 PC DOOR SWEEP WA WEATHER STRIP PRE - INSPECTION ROOM 11 SOLID CORE/LIGHT TIGHT 3068 13/4' WOOD 6 3/4 -2 PC DOOR SWEEP WA WEATHER STRIP FILM PROCESSOR DARK ROOM 18 DARK ROOM DOOR 42' DL 4- FETAL FILM PROCESSOR DARK ROOM 19 DARK ROOM DOOR 42' DL4. FETAL PRE- INSPECTION ROOM 20 DARK ROOM DOOR 42' DL4. METAL FILM PROCESSOR DARK ROOM ,,In, Q Z HOLLOW METAL 6068 METAL k'a 3 /4'STL QC. MAMT. ROOM Ai PR( 22 HOLLOW FETAL - 6068 METAL 3 /45TL COMPRESSOR R.0011 23 SOLID CORE/LIGHT TIGHT 3068 1 3/4' WOOD 3/45TL DOOR SLEEP WEATHER STRIP DARK ROOM XJ6 L 24 SOLID CORE/LIGHT TKsHT 3068 1 3/4' WOOD 3 /4'S7L DOOR SWEEP WEATHER STRIP DARK ROOM AS 25 SOLID CORE/LKGHT TIGHT 3068 1 3/4' WOOD 3/45TL DOOR SWEEP WEATI -ER STRIP DARK ROOMS '01 -, C'NG 26 FETAL ,.... 30613 ... PETAL.., 3 /4'5TL -1 4R 1 HR CLOSURE CHEM. STORAGE DECK 21 • HOLLOW METAL 3068 METAL 3/4 -1 14R I HR CLOSURE CHEM. STORAGE DECK 28 HOLLOW FETAL 3068 METAL 3 /4'STL -1 482 1 HR CLOSURE CHEM. STORAGE DECK 29 HOLLOW METAL 3068 FETAL 3/45TL -1 4R 1 44R CLOSURE 2ND EXIT CHEM. MIX ROOM 30 HOLLOW METAL 3068 METAL 3/4•TL -I HR 1 HR CLOSURE CHEM. MIX ROOM STAIRS SOLID CORE 3068 1 3/4" WOOD 3/451L -2 PC WA 20 MIN. - EXIT CORRIDOR 32 SOLID CORE 3068 13/4' WOOD ' 3/4 -2 PC WA 20 M. OFFICE '106 33 SOLID CORE 30b0 1 314' WOOD 3/4•1L -2 PC WA 20 MIN. OFFICE MOB 34 SOLID CORE 3068 1 3/4" WOOD 3/4•1L -2 PC N/A 20 MN. RECPTION/FOYER RECEIA - Cire drawn by .4RS check by 5 LSB scale date AS SHOWN 8 -14 -91 discipline [Job number 91 -F4 Sheet Number r 5 FUJI TruGolor 710 ANDOVER PARK E. TUKM'LA, HASH. F GENERAL NOTES: THESE GENERAL NOTES ARE TO BE USED AS A SUPPLEMENT TO THE SPEGIFIGATIONS. ANY DISCREPANCIES FOUND AMOUN6 THE DRAWINGS, THESE GENERAL NOTES AND SITE CONDITION SHALL BE REPORTED TO THE ENGINEER. ANY WORK DONE BY THE CONTRACTOR AFTER DISCOVERY OF SUCH DISCREPANCY SHALL BE DONE AT THE GONTRAGTORS RISK. THE .CONTRACTOR SHALL VERIFY AND COORDINATE ALL DIMENSIONS AMONG ALL DRAWINGS PRIOR TO PROCEEDING WITH ANY WORK OR FABRICATION. THE GONTRACTOR 15 RESPONSIBLE FOR ALL BRACING AND SHORING DURING GONSTRUGTION. STANDARDS: ALL METHODS, MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE 1994 UNIFORM BUILDING CODE (UBC) AS AMENDED AND ADOPTED BY THE CITY OF TUKWILA. DESIGN CRITERIA: VERTICAL LOADS: CEILINGS: DEAD LOAD 15 PSF LIVE LOAD 40 PSF SEISMIC: ZONE 3 PER 1494 UBG. Fp= ZIGpWp, Z =03, 1 =1.0, Cp =0.15, Wp =DEAD LOAD OF PORTION OF BUILDING. SOIL BEARING PRESSURE: 2000 PSF ALL FOOTINGS SHALL BEAR ON FIRM, UNDISTURBED EARTH OR STRUCTURAL BAGKFILL. AREAS OVER - EXCAVATED SHALL BE BACKFILLED WITH LEAN CONCRETE (F'c =2000 PSI) OR 'STRUCTURAL BAGKFILL ". AREAS DESIGNATED "STRUCTURAL BAGKFILL" SHALL BE FILLED WITH APPROVED HELL GRADED BANKRUN MATERIAL. MAXIMUM DENSITY AS DETERMINED BY ASTM D- 1551 -18. CONTRACTOR SHALL EXERCISE EXTREME CARE DURING EXCAVATION TO AVOID DAMAGE TO BURIED LINES, TANKS, AND OTHER CONGEALED ITEMS. UPON DISCOVERY, DO NOT PROCEED WITH WORK UNTIL RECEIVING WRITTEN INSTRUCTIONS FROM ENGINEER A COMPt 1 tNT REPRESENTATIVE OF THE OWNER SHALL INSPECT ALL FOOTING EXCAVATIONS FOR SUITABLITY OF BEARING PRIOR TO PLACEMENT OF REINFORCING STEEL. PROVIDE DRAINAGE AROUND ALL WORK TO AVOID WATER - SOFTENED FOOTINGS. CONCRETE: MEZZANINE: DEAD LOAD LIVE LOAD 250 PSF MIN. OR AS LOADED, WHICH EVER IS GREATER CONCRETE: SHALL BE MADE WITH PORTLAND CEMENT ASTM G -I50 TYPE I OR TYPE II, COARSE AND FINE AGGREGATE ASTM C -33, CLEAN WATER AND POTABLE, AND TYPE A (WATER REDUCING), TYPE D (HATER REDUCING AND RETARDING) OR TYPE E (WATER REDUGIN6 AND AGCELERATIN6) ADMIXTURE ASTM G- 494 -80 AND SHALL BE READY MIXED PER ASTM C -94 UNLESS OTHERWISE APPROVED. MATERIALS: ITEM FOOTINGS SLABS ALL OTHER CONCRETE MINIMUM f ' c NORMAL SLUMP 28 DAYS INCHES" MAXIMUM 2500 PSI 2500 PSI 2500 PSI • AT CONTRACTORS OPTION, CONTRACTOR MAY USE MASTER BUILDERS SYNERGYZED PERFORMANCE SYSTEMS USING POZZOLITH ADMIXTURES TO PRODUCE FLOWABLE CONCRETE. MAXIMUM SLUMP SHALL NOT EXCEED 9 ". MASTER BUILDERS CONCRETE TECHNICIAN SHALL ASSIST IN DETERMINING PROPORTIONS FOR SP5 CONCRETE AND SHALL OBTRIN APPROVAL OF ENGINEER PRIOR TO EMPLOYING THIS PROCEDURE. 5 5 PLACE CONCRETE PER AGI 304 AND CONFORM TO AGI 604 (306) WINTER CONCRETING AND AGI 605 (305) FOR HOT WEATHER CONCRETING. USE INTERIOR MECHANICAL VIBRATORS WITH 1000 RPM MINIMUM FREQUENCY. DO NOT OVER - VIBRATE. CONCRETE SHALL BE POURED MONOLITHICALLY BETWEEN CONSTRUCTION JOINTS OR EXPANSION JOINTS. PROTECT ALL FRESHLY PLACED CONCRETE FROM PREMATURE DRYING, EXCESSIVE HOT OR COLD TEMPERATURE FOR SEVEN DAYS AFTER POURING. PROVIDE CONTROL JOINTS AT 28' O.G. MAXIMUM FOR UNEXPOSED SLABS, INCLUDING TOPPING SLABS, lb" O.G. MAXIMUM FOR EXPOSED SLAE�S. SUBMIT DRAWINGS WITH CONTROL JOINT PATTERN FOR ENGINEER'S APPROVAL PRIOR TO PLACING. NON - SHRINK GROUT: MAKE FROM ONE PART ASTM G -I50 TYPE I PORTLAND CEMENT, ONE PART FINE SAND ASTM G -33, AND ONE PART "MASTER -FLOW 113" BY MASTER BUILDERS OR EQUAL. MIX DRY AS GAN BE WORKED, OR MIX TO A FLUID CONSISTENCY AND PACK OR POUR SOLID TO FILL SPACE UNDER PLATES OR SHAPES. USE "EMBECO 636" FOR NONEXPOSED WORK. METAL REINFORCEMENT (CONCRETE): ALL REINFORCING SHALL CONFORM TO ASTM A -615, GRADE 40 FOR *5 AND SMALLER, GRADE 60 FOR *6 AND LARGER. DETAIL, FABRICATE AND PLACE PER AGI 315 AND AGI BIB. SPLICES SHALL BE 24" DIAMETERS OR 18" MINIMUM FOR CONCRETE. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A -82 AND A -185. LAP ONE FULL MESH ON SIDES AND ENDS. PLAGE AT MIDDEPTH OF SLAB, OR AS SHOWN. FUJI TruColor 110 ANDOVER PARK EAST TUKWILA, WASHINGTON STRUCTURAL SILLL: MAGHWE BOLTS (MB) AND ANCHOR BOLTS (MB.): ASTM A -301. PRO I FD IN ANCHORS: PARABOLT" BY USM, INC., MOLLY FASTENER DIVISION, 'RAYS- BOLT', OR APPRCVED EQUAL. EMBED BOLT INTO CONCRETE 1" DIAMETER 4Kir�IN&Ri, EXCEPT AS SHOWN. GARPEN1RY: PLYWOOD (STRUGauRAL). SHALL BE GROUP I OR GROUP II SPECIES, GO GRADE EXPOSURE -I C.OH FORMJNG TO PS -I -83. EACH PIECE SHALL BEAR THE GRADE TRADEMARK' THE AMERICAN PLYWOOD ASSOCIATION. FRAw I "G LU 2: GOw` =ORM TO HEST COAST LUMBER INSPECTION BUREAU (MCLIB ), OR Y€STERN WOOD PRODUCTS ASSOCIATION (WWPA). EACH PIECE SHALL BEAR THE MCLIB OR WWPA GRADE TRADEMARK. SPE AND GRADE: I_ BEAMS AND HEADERS: 'DOUG FIR I LARCH" No. I 2. BLOCKING: 'DOG FIR I LARCH" No.3 OR "HEM FIR" No.2 3. EXTERIOR STUD WALLS: 'DOUG FIR I LARCH' No.2 OR "HEM FIR" No.2 4_ THY MINIMUM GRADE OF ALL OTHER STRUCTURAL FRAMING: "DOUG FIR" No.2 OR 'HEM FIR' Eo2 GENERAL E GIU1RE ENTS: PROVIDE MINIMUM NAILING PER 1114 UBC TABLE 23 -I -0 OR MORE, AS OT RINISE S'r1014N. ALL WOOD IN CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE TREATED MATERIAL. PROVIDE GUT HASHERS 14ERE BOLT HEADS, NUTS AND LAG SCREW HEAD BEAR ON WOOD. FRAMING CONNECTORS: ALL FRAMING CONNECTORS SHALL BE CEO APPROVED. TYPE OF CONNECTORS SHALL CONFORM TO THOSE GALLED OUT ON DRAWINGS OR AND APPROVED EQUAL. CONTRACTORS GALLED OUT ARE SIMPSON STRONG TIE CONNECTORS AS MADE BY SIMPSON STRONG TIE COMPANY INC. SUBSTITUTION. SUBSTE'R ONS MAY BE ALLO}'ED ONLY IF THEY MEET THE REQUIREMENTS OF THE SEN_ RAL NOTES AND SPECIFICATIONS, AND APPROVED BY THE ENGINEER. DIAL INSPECTIONS: I_ TIE OKNE3R SHALL EMPLOY A SPECIAL INSPECTOR WHO SHALL PROVIDE INSPECTIONS DURING CONSTRUCTION ON THE FOLLOWING WORK: A STRUCTURAL Y DING ON SITE BY CERTIFIED WELDER. B. HIGH STRENGTH BOLTING 0 MEZZANINE FRAME. IT CENTER WILA REVISION PER BUILDING DEPT. LITTER 8 -5 -91 • client FUJI TruGolor 770 ANDOVER PARK E. TUKWILA, WASHINGTON Sheet Description SPECIFICATIONS 11 N II /1 /' ONE HOUR WALL /; 2 x 6 FRAMED WALL W/ 5/8" TYPE 'X" GWB EXISTING 6" BOTH SIDES GONG. TILT -UP WALL TYPICAL i I/2 " McNIGHOLS / x 40# SB x 18.4# FLOOR GRATING 6 - of - 7 LSE scale = 4 " /, � IIie (2) L3 x 3 x 3/16 I /4,' \ W/(6) 5/8" BOLTS (A325) \ \ `3/4" PLATE KNEE BRAGINS(TYP.) 4 "x 4 "x 1/4" 6 "x6 "TS- � 6 "x 6 "x3/8" TS I I 56 x 12.5 US ± FOR LATERAL SUPPORT . NON - BEARING BEAM I 1 1 -6 "x 6" TS I I I j 5 I/2" GONG. SLAB 1 - drawn by JRS check by 6 - of - 7 LSE scale date AS 51-1O1 8 -14 -T7 discipline Job number q Sheet Number 6 6 - of - 7 -KNEE BRACING (ri P) 4 " "x1 /4" S8 x 18.4# ® 4' O.G. I b "x b" x3/8" TS ASTM A500 (4)7/8" DIA. x 12" BOLTS 12 "x 12 "x 1/2" PLATE #4 BARS ® PERIMETER (4) #5 BARS EACH WAY FOOTING DETAILS "A" "B" "D" SCALE 3/4" = I' #4 BARS e 12" O.G. (5) #5 BARS b "x 6" x3/8" TS STEEL COLUMN 16 "x IS" GONG. PIER b "x 6" x3/8" TS ASTM A500 (4) - #4 BARS . 16 "x 16" CONC. PIER (4) - e4 BARS #5 BARS e 18" O.G. EACH WAY L 4 4' -3" 4'-6" 3' -0" 3'-q" - BB 4' -6" - GG 3' -O" - AA 3' -q" - BB �I. J J J FOOTING DETAILS "A" "B" "D" SCALE 3/4" = I' 56 x 12.5# USE FOR LATERAL SUPPORT NON - BEARING BEAM KNEE BRAG INS(TYP.) 4 "x 4 "x 1/4" IA� I B. 1 5'x � 3'x 15" L. -1. -J 3'q "x j3'q "x 15" I I 1 I I I I I i i EXIST. I I I POST I I I I SUMP I 1 EXIST.I I I FTS. i I 1 ' � I L - r - - - - -J I I IN- EXISTING i I 1 b b" " CONG. 4 11 I ' I \!- b x 6 „ j LI DI J LGG -J METAL L D D i J I1 ~T t COLUMN T - - : 4'3"x 4'3 "x IS ° FLOOR I (q) TYPICAL 4'3 "x 4'3 "xil5" 1 I 14" EL. , 48.83 I I i 5' -b" - j 3'x 3'x 15" 1.__'1 s CON LJ S8 x 18.4# W12x40# SCALE 3/4° = I' 5 1/2" GONG. FLOOR FINISH FLOOR EL. 100.00 1/4" 5 6 R.1 E r" L • REGESSEi 12' -8 1/2" SCALE I/4 1' i 3 "x 3 BB T • I 2q' -5" (2) L3 x 3 x 3/16 W/(6) 5/8" BOLTS (A325) 3/4" PLATE KNEE BRAGING(TYP.) 4 "x 4 "x 1/4" 6 "x 6 "x3/8" TS 2ND FLOOR BEAM DETAIL FUJI TruGolor T70 ANDOVER PARK EAST TUKWILA, WASHINGTON 6" GONG. ! FOUNDATION WALL I I I ' #4 BARS 0 12' 0.G. i 1 VERT. d HORIZ. i 12 "x b" GONT 1 FOOTING - AA. -- L_ I 1 r S P - I — f v ► I I 3`xi3'x 15 "k1 5 1/2" GONG. FLOOR t i'� i RECESSED 42" EL. q65 ! '"-I2 "x 6" GONT. FTG. 1 *4 BARS EXIST. FRAME WALL 12' -8 I /2" FOUNDATION PLAN / MEZZANINE 1 EXIST. GONG. SLAB AFTER GUTTING *4 DOWEL @ 48" O.G. DRILL 4 EPDXY MIN. 6' EMBED NEW 5 1/2" GONG. SLAB SCALE 3/4" 3' #4 DOWEL ® 48" O.G. DRILL 4 EPDXY MIN. 3" EMBED. ENCASE DOWEL H/ GONG. G 16 "x 16° GONG. PLINTH (4) TYPICAL #4 DOYL 0 12" O.G. VERT. DRILL d EPDXY INTO EXIST. MALI- I.. MIN. 3" EMBED. FOUNDATION DETAIL SAW OJT ROUGH OPENING IN GONG_ WALL 36" x84° '*B3 EXISTING FRAME #4 DOWEL 0 48" O.C. EXISTING b° GONG. WALL To! � TYPICAL 11/2" x McN GHOLS N FL GRATING i m I KNEE BRACING (TYP) - 4" x 4. x ii4" FTG_DI 45°x 45'x 15" WEST SIDE SS x 18.4# ® 4' D.G. N I BEAM I x IN SCALE 1/4 "= I' 2x12 DF #2 ria }6" 0. I ill n 1 EXISTING 4 x IS a 5' D.G. "-2 x 12 LEDGER { --SIMPSON HU212 12' -8 1/2" 11 -2 I I I x 6 FRAMED II �2 x 6 FRAMED ALL l-(2) 2 x 12 FLOOR FRAMING PLAN / MEZZANINE NLC_ 1 FTC. CC 4'6 "x 4'6"x 15" EAST SIDE I BEAM TYPICAL 2000# LOAD FROM GHEM. MIX TANK COLUMN (q) TYPICAL WALL (2) 2 x 12 PEN FOR STAIRS \� EXIST. 2 x b FRAME WA 12' -8 1/2" 16 "x IS" FTS.� 4'3 "x 4'3 x 6 "x 6" WF BEAM METAL 56 x 12. ' I i#4 i L LI�I - �l H -J TU I1i6 , Ov "tt� AUG 2 1 1237 SECTION A -A / MEZZANINE _ SCALE I /4'= I EXISTING 5" GONG. WALL S8 x 18 4# a 4 O.G. I - xl NI Sb x 12.5# EXISTING 6" GONG. WALL RECEIVED CITY OF TUKWILA PERMIT CENTER REVISION PER BUILDING DEFT. LETTER 8 -5 -q client FUJI TruGolor T70 ANDOVER PARK E. TUKWILA, WASHINSTON Project FUJI TruGolor 110 ANDOVER PARK E. TUKWILA, WASH. Sheet Description FOUNDATION PLAN MEZZANINE PLAN - drown by -IRS chock by LS13 scale date AS SH9v4N a-I4-11 discipline Job number 17-F4 Sheet Number 1 7 7 NALL - R-I1 INSULATION I 15 x 24' EXIST. FRAME ir Li 11 1i 11 _ _IL EXIST. 5 1/2" GONG. TILT-UP WALL NO INSULATION 5'x 249 EXIST. 5 1/2" CONG. TILT-UP NALL NO INSULATION (35'x 24) — 1 r — i OFFICES ti II il LPA 1.2 NV S?.FT. II NEW R-30 1 in _ — = _ — _ I INSULATION 4140 T - 1 1 2,E5b SO FT II I I L 1 ; 11 d li n II I I L _ _ L _J L EXIST. 5 1/2" GONG. TILT-UP NALL NO INSULATION (50' x 24) Fl — — OTHER ROOFS - R-30 MIN. OPAQUE HALLS - R-1.1 MIN. (4 NEW FRAME MALL #1 EXIST. FRAME WALLS - R-I1 EXIST. GONG. HALLS - R-0 @ GONG. HALLS (UNINSULATED) VERT. GLAZING - U.10 DOORS - UNINSULATED PERIMETER SLAB - UNINSULATED HEATED SPACE SCALE :/e,` = FUJI TruGolor - I - TO ANDOVER PARK EAST TUKHILA, HASHINGTON EXISTING R-M INSULATION— @ HALL (205' x 249 HEATED I COOLED - 1 II il ,,,-- NEH R-1 INSULATION CI i 1 II in r— — 11 P I ill I II I ON I . N___ NE1 R-I.1 INSULATION t' 1 11 1-1 II u= (4s• x 249 i[ Ji II 11 P II NEVI R-30 U II ii UP. HE.AT II HEATED LI INSULATION-CEILING NI II II NEVI FR.-30 INSULATION-CEILING 11 0 #1 11 STORAGE STORAGE I I il LPA .5 kV SO FT LPA 5 kV SO FT ,,1 TILT-UP NALL 11 II ;i II = I =II c-- IL L _i L __J I NO INSULATION Z-- -1 @ HALL (135' x 249 II I EXISTING R-I1 INSULATION ----' ENVELOPE REQUIREMENTS: HEATED TENANT SPACE MANUFACTURING LPA 15 IN/ SG . NEVI R-30 INSULATION-CEILING 11,62c1 SO FT N.R.E.C. INFORMATION C. N.R.E.G. INFORMATION alike • /2 14atis/SF -or,4* e • .5 klatts/SF Picreacturing • 15 Watts/5F Qdk Feuer Allowance LigreIng Rover Allowcree Office a 29127 SF • 1.2 14/5F Storage di 2532 SF • 5 14/5F Maroracturing *1529 SF 15 14/SF .orage - (1)1 , e Fluorescent x 192 = 2 Sows McrurocturIng - (e5)1 x 4* Huorescont x 192 = (10) Incandescent x 50 1 = F r 4N_ NO PERIMETER INSULATION 3440 IA 1266 14 1 14 Office - (29.) 2 x 4 Fluoresced x19214 = 5568 4 lamps PLII*C*.C.. DI 1344 14 izocts 1,500 14 Proposed Lighting Total 20,504* CITY OF TUKWILA 22,150 14 APPROVED AUG 2 1 11397 AS niOiLD RECEIVED CITY OF TUKWILA PERMIT CENTER REVISION PER BUILDING SEPT. LETTER client FUJI TruGolor T70 ANDOVER PARK E. TUKNILA, WASHINGTON Project FUJI TruGolor 170 ANDOVER PARK E. TUKWILA, WASH. Sheet Description N.R.E.G. INFORMATION t • NI% Qt EXISTINE WATER MAIN 1,2 I II EXIST, r♦ SATE VALVE PX157. eAs _ IT ST. WATER MAIN AUTOMATIC SPRINKLER VALVES #720 TRANSFORMER VAULT EXIST. CB #730 IFJaST. EAS METER 15 - -EXISS 6A5 _ �XLSr <aa REMOVE EXIST DETECTOR SINeI E L4ECK VALVE AND INSTALL NBN DETECTOR DOUBLE CHECK VALVE AND 14I % vJ VAULT AS°.- ,EM3LY AT SAME LOCATION AS EXISTINS. - • rr ANDOVER PARK EAST ;% **VI' FUJI Trut..oIor PARCEL #2b2304- clOci5 110 ANDOVER PARK EAST TUKWILA, WASHINGTON EXIST. — — 4225T NI °4'28 "E FUJI TruGolor #770 gEPLRC.E _E XiSI. C9TN BA ,AI LAO NEW TYPE �i CFYTC" 895 ^/ yfCONHODF,TE NEB.] - TSR Ss 79 U L_ DRIVEWAY — Fin T TORM NI ° 47'28 "E c ■ SITE PLAN SCALE !- = 20 • J F I ! I EX.' 2' HATER LEE t I DRIVEWAY #7qo EXIST. LS EXIST. 2• MET. — E7asT. S RM 5M B4 PK'SL STORM S88R SAN. sasz — — A — � \ 1 / EXIST. / STORM s ,4 . ! gX15T. WATT CITY OF TUKWIIA 4PPROVTO AUG 2 11507 r b ECTLG'�.0 PI MCN ' J �j ECEIVED CITY R OF TUEWIL$ PERUE+'CENTE.R ee DescrIp on SITE PLAN discipline drawn by scale 5 5 Sheet Number GI of 2 0 num.er JRS date 8- 14 -9 9 7 -F4 G REVISION PER PUBLIC WORKS LETTER 00 J L client FUJI TruGolor ?TO ANDOVER PARK E. TUKWILA, WASHINGTON Project FUJI TruColor TTO ANDOVER PARK E. IUKWILA, WASH. I l ob number r q'7 -F4 Sheet Number 2 '02 -°' - 2 o • GENERAL NOTES I. ALL WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITH CITY STANDARDS AND MOST CURRENT COPY OF THE STATE OF WASHINGTON STANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION (WXDOT /APWA) AND AMENDED BY THE CITY. 2. GALL THE UNDERGROUND LOCATE LINE I -8OO- 424 -5555 A MINIMUM OF 48 HOURS PRIOR TO ANY EXCAVATIONS. 3. THE STORM DRAINAGE SYSTEM SHALL BE CONSTRUCTED ACCORDING TO APPROVED FLANS ON FILE WITH THE MUNICIPALITY. ANY SIGNIFICANT DEVIATION FROM THE APPROVED PLANS WILL REQUIRE WRITTEN APPROVAL FROM THE MUNICIPALITY. 4. A COPY OF THE APPROVED STORMWATER PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. • 5. IT SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN STREET USE AND OTHER RELATED OR REQUIRED PERMITS PRIOR TO ANY CONSTRUCTION ACTIVITY IN THE MUNICIPALITY'S RIGHT -OF -WAY. IT SHALL ALSO BE THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN ALL REQUIRED PERMITS PRIOR TO ANY CONSTRUCTION. THE CONTRACTOR SHALL ABIDE BY ALL REQUIREMENTS FOR TRAFFIC CONTROL AND SAFETY WHEN WORKING IN THE ROAD RIGHT -OF -WAY. 6. ALL DRAINAGE STRUCTURES, SUCH AS CATCH BASINS AND MANHOLES, NOT LOCATED WITHIN A TRAVELED ROADWAY OR SIDEWALK, SHALL HAVE SOLID LOCKING LIDS. ALL DRAINAGE STRUCTURES ASSOCIATED WITH A PERMANENT RETENTION/DETENTION FACILITY SHALL HAVE SOLID LOCKING LIDS. DETECTOR DOUBLE CHECK MATERIAL LIST I. 3/4" SHACKLE RODS WITH STAR BOLTS AND ASPHALT EMULSION COATING. 2. 4" MIN. D.I. CLASS 52 PIPE. 3. PRECAST CONCRETE VAULT WITH HINGED STEEL PLATE COVER, DIMENSION TO VARY WITH SIZE OF ASSEMBLY. 4. O.S.H,A. APPROVED LADDER IF OVER 30" DEEP. 5. PIPE SUPPORT STAND UNDER EACH CHECK VALVE. S. COPPER OR BRONZE BYPASS WITH AN APPROVED DCVA. 7. 3/4" WATER METER. G. APPROVED DDGVA IN MAIN LINE WITH TWO RESILIENT SEATED SHUTOFF VALVES AND TEST COCKS. G. I G ", 6" OR 4" COUPLING ADAM i i=R, FL. 10. I" 5 ", 5" OR 4" FL "PE D.I. GLASS 52 PIPE LENGTH TO FIT. II. GROUT INTERIOR AND EXTERIOR ALL AROUND PIPE USING NON - SHRINK GROUT. 12. '10 ", 8 ", 6" OR 4" GATE VALVE FL"M_1 WITH POST INDICATOR VALVE. 13. FLANGE TEE ASSEMBLY SIZED ACCORDINGLY. 14. FLANGED GO° TO BEND. 15. 4" OR 6" D.I. GLASS 52 PIPE FL"FL 16. 4" OR 6" 40° BEND FL. I7. 4" OR 6" D.I. GLASS 52 PIPE FL #FL 18. 6" 10 °. BEND, FL. I. UL LISTED 5" STORTZ CONNECTION WITH 30 OR 45 DEGREE ELBOW. 20. 6" D.I. CLASS 52 PIPE LENGTH AS REQUIRED FL #FL 21. 6" GO° BEND FL. 22. SWING TYPE GRAVITY OPERATED CHECK VALVE WITH BALL DRIP VALVE TO BE INSTALLED HORIZONTALLY. DETECTOR DOUBLE CHECK AND VAULT ASSEMBLY NOTES: I. BACKFLOW PREVENTORS SHALL BE FEBCO #806 OR APPROVED EQUAL. 2. SIZE VAULT BASED ON SIZE OF APPARATUS AND MEETING MINIMUM CLEARANCES. 3. A SEPARATE DETAIL PLAN FOR VAULT INSTALLATION AND SPRINKLER LINE MUST BE SUBMITTED AND APPROVED BY THE FIRE MARSHALL PRIOR TO INSTALLATION. 4. MINIMUM APPARATUS SIZE SHALL BE 4 ". 5. VAULT SHALL BE SEALED TO PREVENT WATER LEAKAGE. 6. LADDERS SHALL BE REQUIRED WHEN DEPTH FROM TOP OF LID TO FLOOR OF VAULT EXCEEDS 30 ". INSTALLATION OF ALL LADDERS SHALL SE IN COMPLIANCE TO O.S.H.A. .7. LOCATE VAULT IN PLANTING AREA AND NOT IN PAVING AREA, UNLESS APPROVED BY THE ENGINEER. S. FITTINGS SHALL BE IN ACCORDANCE WITH ALL APPLICABLE REQUIREMENTS OF ANSI /AWWA CI10 /A21.IO AND CEMENT LINED (SEE APWA d AMA). G. PIPE SHALL BE DUCTILE IRON MEETING ANSI A215I, CL52 8 GEMENT LINED. 10. TEMPORARY SUPPORT SHALL BE PROVIDED UNDER VALVES AT THE TIME OF INSTALLATION, AFTER COMPLETE INSTALLATION INSTALL PERMANENT PIPE SUPPORT STAND. II. PROVIDE BALL DRIP VALVES ON F.D.G. CHECK VALVE ASSEMBLY OR AT BOTTOM OF F.D.G. RISER. 12. FIRE DEPARTMENT CONNECTION TO BE PROVIDED WITH ONE (I) 5" STORTZ CONNECTION AND TWO 30 DEGREE ELBOWS. 13. ALL UNDERGROUND PIPING TO BE INSPECTED, FLUSHED, PRESSURE TESTED IN THE PRESENCE OF AN INSPECTOR PRIOR TO COVER AND CONNECTION TO THE OVERHEAD SYSTEM, 14. UPON INSTALLATION, BACKFLON PREVENTION ASSEMBLIES ARE TO BE TESTED BY A CERTIFIED TESTER AND ALL TEST -COCKS ARE TO BE PLUGED AFTER THE TEST. THEREAFTER, ANNUAL TESTS SHALL BE PERFORMED AT OWNER'S EXPENSE, AND COPIES OF TESTS RESULTS SHALL BE PROVIDED. 15. CONCRETE VAULT SHALL HAVE ONE ` 4'x 4' OR TWO 3'x 3' STEEL HINGED DOORS. ' TO BUILDING WITHIN 50' OF HYDRANT COMPALTED FOUNDATION GRAVEL UNDER VAULT FUJI TruGolor ?TO ANDOVER PARK EAST TUKWILA, WASHINGTON PLAN VIEW C. 1' MIN. UNDER t PAVEMENT '} 16` MX. I= 777 �IAaill�� /� MAX. D SIGN W.S. INSTALL NEW (6' 4 EL = 421.90 O- 11 OFR UTLET P T PIPE 2 EXIS FO EM P IPE SUPP�TS '(�I OIL /WATER SEE NOTE-6 n :.. SEPARATOR NOTES OUTLET PIPE SEE NOTES I ELBOW RESTRIC SIDE VIEW 1. DESIGN FOR 4' TH?! 10' VOGV_ DETECTOR DOUBLE CHECK VALVE ASSEMBLY AND VAULT ANGLE AS NECESSAR SEE NOTE 7 FRAME E. GRATE SECTION A -A PSI SCALE 2' MIN. CLEARANCE TO ANY PORTION OF FRLF -T INCLUDING ELBOWS PLAN VIEW XIST. STORM MH STD. GALV. HANDHOLDS STEPS OR LADDER SHEAR GATE W/ CONTROL ROD FOR CLEANOUT /DRAIN (ROD BENT AS REQ'D FOR VERTICAL ALIGNMENT W/ COVER) NOT TO SCALE ADDITIONAL LADDER RUNGS (IN SETS) TO ALLOW ACCESS R VAULTS WHEN CATCH IS FILLED WITH WATER 48" CMP 2 CUP NOT EMERGENCY OIL /WATER SEPARATOR DETAIL 1. USE MIN. 48' DIA. CATCH BASIN TYPE 2 2. OUTLET CAPACIT`SEVELOPED Q 3, METAL PARTS' CORROSION RESISTANT. GAVANIZED PIPE PARTS TO HAVE ASPHALT TREATMENT 1. 4, FRAME 8, LADDER OR STEPS OFFSET SO' A. CLEANOUT GATE IS VISIBLE FROM TOP. B. CLIMB -DOWN SPACE IS CLEAR OF RISER AND CLEANOUT GATE. C' FRAME IS CLEAR OF CURB, 5, IF METAL OUTLET PIPE CONNECTS TO CEMENT CONCRETE PIPE' OUTLET PIPE TO HAVE SMOOTH O.D. EQUAL TO CONCRETE PIPE I.D. LESS 1/4', 6. PROVIDE AT LEAST ONE 3' X .090 GAGE SUPPORT BRACKET ANCHORED CONCRETE WALL iMAX. 3' -0' VERTICAL SPACING). 7. LOCATE ELBOW RESTRICTOR(S) AS NECESSARY TO PROVIDE MIN. CLEARANCE AS SHOWN. 8. LOCATE ADDITIONAL LADDER RUNGS IN STRUCTURES USED AS ACCESS TO TANKS OR VAULTS TO ALLOW ACCES WHEN CATCH IS FILLED WITH WATER CrF' OF TUKWILA, 0J:N01100 00'32 j 19 " 7 rC RECEIVED CITY OF TUKNJII A PERMIT CENTER f2tV ICON +%I pUS1 -it 11JOfZK6 LETTER S -1 -17 client FUJI TruGolor 110 ANDOVER PARK E. TUKWILA, WASHINGTON Project FUJI TruGolor TIO ANDOVER PARK E. TUKWILA, WASH. Sheet Description DETECTOR DOUBLE CHECK VALVE ASSEMBLY 4 VAULT drawn by _IRS check by II — III LSB scale date AS SHOWN 8 -14 -97 discipline I job number 97 -F4 Sheet Number E —I —of -- 3 1 VILA41L/"4, YIr, --N, M,,a.., I Vit NORTH II' -II• 12 -7 96` -:l• 56 V2' �'3 YI 2'YN S'i• 5' -2' 90'd• E v I� ayAD novAC was, DUPLE, OUTLET SL SHTCH+wcovBR � SHrcN Ilnrr 5 3C 3 YNY SNITCH hi/COVER 14CMJDEaisa EXIT z 4 FLUORESCENT — 1 1 x B FL.UORESC8fT 2 x 4 FLUORSG@tT 2 x 4 FLUORESCENT (EXIST) 1 x 6 FLUORESCENT tJpST) 0 4,44 .LNCTION BOX INFRA-R® NOTE L FLUORESCENT TUBES • ALL DROPPED FLUORESCENT FIXTURES USE COOL HIVE DEIAIE LAMPS 2, FILM PROCMOR DARK ROOK HR® SO EVEMHMB EC. OFF HEN ROHM 15 MTGE!, OFF RACK #I PANEL S -I (277/480) PIPE # H -I 6 - #IO H -2 3 - #10 H -3 0 H -4 6 -#I0 PANEL 5 -2 (120/208) PIPE # 5 -I 0 L -I q - #10 L -2 0 L -3 4- 3/0,1 - #6 L -4 9 - #I0 L -5 3 - #10 L -6 4-#10 HVAG BATT. CHARGER LIGHTING SPARE HVAG SPARE PRINTING FILM PROC. FILM PROC. NOTCHING, CHEM. RM SPLICING .$ SORTING CHEM. R.M. LITES d OUTLETS 170 ANDOVER PARK EAST ELECTRICAL PLAN SCALE 1/8' = I' " FUJI TruGoi RACK #2 PANEL N -I (211/450) PIPE # H -5 3-#2, I-#4 H -6 5-#6 H 7 4-#12 G FEED TO EXIST- PHI. COMPRESSORS TASK LIGHTING PANEL N -2 (120/208) I" PIPE # L-1 4 #10, 1-#12 MAINT, 8 DARKROOMS I -1/4" L -8 0 ROLL PAPER PROC. 2" L -9 4-3/0, 1-#6 ROLL PAPER PROC. 2" L -IO 7-4t10 PACKAGING, PRICING I -I/4" L -II 7-#10 PACKAGING,GIJ"ITERS L -I2 5-#8, I-#IG ENLARGERS 3/4 L -I3 II -#'.o, 3-#12 FILM € PRINTER PROC. L -14 3-#10 AIR DRYER 2ND ELECTRICAL PLAN SCALE I/8• = I . 1 -i/2" 1 -I /4° I" 1° 2" 2° I -1/4" I -1/4" I -1/4' I -1/4" 111IIIIIIIIIl1»IIIII IIiin11;i1„i RON.EHICAL STORAEE 54' OC.PANCY C94. MIX ROC. • PI ED CEXAL FFIIMiE Is CONSTRUCTED I PAO CCFAILY M.ARATIOi MALL ffM1®N ADSYER ROOMS ALL °PENN. PROTECTED WA I Tit FIRE RATED AS LY 20 RISERS • 1.2• M TREADS • 10 11-1 CI1 ANC L Mt72ANiNE I 1000 SALS-IRR IS OPEN sRATHB, NET AREA > - 1Oli OP. • ACCEf LADDER , FALL PROTECTION LASE FALL PROTECTION TO START AT A HE IGHT OF H' City OF TUKWILA APPROVED AUG 2 1 1937 NILD RECEIVED OF TUKWiLA PERMIT CENTER REVISION PER BUIL DINS DEPT. LE!!tR 8 -5 -G7 PER PUBLIC WORKS LE I I tR 8 -7 -97 Project client FUJI TruColor 770 ANDOVER PARK E. TUKWILA, WASHINGTON FUJI TruColor TTO ANDOVER PARK E. TUKWILA, WASH. ee Descrip ion ELECTRICAL PLAN 1 VILA41L/"4, YIr, --N, M,,a.., I Vit NORTH II' -II• 12 -7 96` -:l• 56 V2' �'3 YI 2'YN S'i• 5' -2' 90'd• II — III . , PH.6E Wr -0PP SHITLN I.. - n ' i� � ti tr\T,7+Ii'� r �_ • L � ' TA , i R . Q e u GOMPRL�f�OR ROOM REGE � Ib x ib w WGT __1'" N " - - - E CATHALK - _ v' __ IVER !'7 S m w � _ :. �`- _� s ., - -<„ - /AIM y Fi EXIT OFFIC HsO SO PT - __._ 1,' - ^ � _� _ __.r J�i��I.i'�.�LII��� ■ °- .mar -__ ___ ` i° _ {G»�_YA �Y t�l ..e....„ �w.a O a r ��SI f319PGH vooi[s ❑ • qm b i'!►+ i 1 E . E t j l / .d :. I,Ke _ i' — carrmoa C � ��s i — '- —, - � i'i ���E;� 1 p F ' I � ;il! ' "'r ' 4A 4A x n n T10N 1 4 t4 t 2 1I A4 zi ' RE IowFOYER� 196 F { UI J ®3 PA RU9. !PAPER PROCESSOR _ O OFFICE A,vFA9 • I I .. .. -, I Q.G. d t %'� o • 1 1st R we _.. S M" o XI ET Ir a u - y I I '- ,_ 45 3 01 10 a ; CATNALK ©© F ® OFFIt u» w n E I -' F T i 1 i ll f I t i4� 12 14 I tZ' ! 1 .... - .. PLANT AREA ' 01 in OFFICE gI V (2) SOW 000DOORS I I I I ! \ Sa FT E OFFICE ! , I a 4.4o SO FT _ G -� d j 11 I ..,. G 1 11 I F 1 OCaE, n • LI + in 0 I i I 1t Q ' _ I : _'. �I - _ .IA R Nil T1 30 sa Fr E ' ti ® tS i'I , PR AIR ICING A!p NG SHIPPI N3E6 oEWeil , I 1 / ELECTRIC LAYOUT COJDITIOlED / IEA7®SPACE O I e'-4• OFFICE EXIT y , 9 ISRT I1 n O F ® 1 R \Q/ I J' ❑ H E 7 n EGUIPF8�7 P. ■ _ ... - - _ „1�i =„ I - -� T� �. 0 el 111111111' ! ,o li r II :r ■S I I *4416 / I/4 i DO OR OPENER 5 ADTM I I r .. = \i L1 2 . p1A• WP`s o � y ELECT. CST rl�r.�''°� t i i_� ...Li. +i r ,.. ¢0= ROOCS I I 20 RISERS 7.2" II� 19 TREADS O 10 DOOR OPENER ■ I I \ KEY ' II �Y- '' _ t".. .�- Y - 2 ._ 2 . 1111 4 F ` .. ...�..� ��I I!� RECEMN6t 4x 12 1111 �8tr. q DOOR P 4RTMI OPPoSTE , LIFT /V PLASTIC y y 1� �f I 1 �u .>R� y 111 _ �� 11— -��1.' j / — S FIIPPINS O I ry 4' z 4` PAL9Ef PAL1Ei III 3 ' _ 11 1 % - RACK SINK 42' 61INJIDRAC 9 -1 0, 13' �-1 1 L L k N 11 _, I • P i 1400 6 ` -o L _ 41 } Q§ ^' 1 l u NO HEAT TRUCK B A Y S ! i GIRT�AN e. QA pyBg.c t >L TEMPERED rsa ...TER caNrL_ pi. ARTRHDSE LOCATION ®� t + I Lam — STORAOERA05 _ G�1 *I Gs I I x ° I p h 4. S E k I I ° I ¢ I II I D' 1 i - • �• II' - �— • ! I 1 1 1 �' C H6' _ _ SEM -HEAT SPACE SEAT RAC MOVE 'O=° b t E E 19 S TORAGE p pp g I I S-1 OCafP < IOOO SAL ..tAsa'Ri7z AREA p 1 I STDRASE AREA 9 t F e _ il SA OCCUR E 1� I I EAST61. S v W BANE O R OCCLPANCT SEPARATM MU, NV RATED Y A � ';'�. . � i 7iii;� '. C C I SfQtAEERrOLS I 1 1Il in i! !. IIIIIH .. ri. 1 I B SOUTH 104'$ 3p' -2• 20' -II' 32'-9' 24'3' 212E E v I� ayAD novAC was, DUPLE, OUTLET SL SHTCH+wcovBR � SHrcN Ilnrr 5 3C 3 YNY SNITCH hi/COVER 14CMJDEaisa EXIT z 4 FLUORESCENT — 1 1 x B FL.UORESC8fT 2 x 4 FLUORSG@tT 2 x 4 FLUORESCENT (EXIST) 1 x 6 FLUORESCENT tJpST) 0 4,44 .LNCTION BOX INFRA-R® NOTE L FLUORESCENT TUBES • ALL DROPPED FLUORESCENT FIXTURES USE COOL HIVE DEIAIE LAMPS 2, FILM PROCMOR DARK ROOK HR® SO EVEMHMB EC. OFF HEN ROHM 15 MTGE!, OFF RACK #I PANEL S -I (277/480) PIPE # H -I 6 - #IO H -2 3 - #10 H -3 0 H -4 6 -#I0 PANEL 5 -2 (120/208) PIPE # 5 -I 0 L -I q - #10 L -2 0 L -3 4- 3/0,1 - #6 L -4 9 - #I0 L -5 3 - #10 L -6 4-#10 HVAG BATT. CHARGER LIGHTING SPARE HVAG SPARE PRINTING FILM PROC. FILM PROC. NOTCHING, CHEM. RM SPLICING .$ SORTING CHEM. R.M. LITES d OUTLETS 170 ANDOVER PARK EAST ELECTRICAL PLAN SCALE 1/8' = I' " FUJI TruGoi RACK #2 PANEL N -I (211/450) PIPE # H -5 3-#2, I-#4 H -6 5-#6 H 7 4-#12 G FEED TO EXIST- PHI. COMPRESSORS TASK LIGHTING PANEL N -2 (120/208) I" PIPE # L-1 4 #10, 1-#12 MAINT, 8 DARKROOMS I -1/4" L -8 0 ROLL PAPER PROC. 2" L -9 4-3/0, 1-#6 ROLL PAPER PROC. 2" L -IO 7-4t10 PACKAGING, PRICING I -I/4" L -II 7-#10 PACKAGING,GIJ"ITERS L -I2 5-#8, I-#IG ENLARGERS 3/4 L -I3 II -#'.o, 3-#12 FILM € PRINTER PROC. L -14 3-#10 AIR DRYER 2ND ELECTRICAL PLAN SCALE I/8• = I . 1 -i/2" 1 -I /4° I" 1° 2" 2° I -1/4" I -1/4" I -1/4' I -1/4" 111IIIIIIIIIl1»IIIII IIiin11;i1„i RON.EHICAL STORAEE 54' OC.PANCY C94. MIX ROC. • PI ED CEXAL FFIIMiE Is CONSTRUCTED I PAO CCFAILY M.ARATIOi MALL ffM1®N ADSYER ROOMS ALL °PENN. PROTECTED WA I Tit FIRE RATED AS LY 20 RISERS • 1.2• M TREADS • 10 11-1 CI1 ANC L Mt72ANiNE I 1000 SALS-IRR IS OPEN sRATHB, NET AREA > - 1Oli OP. • ACCEf LADDER , FALL PROTECTION LASE FALL PROTECTION TO START AT A HE IGHT OF H' City OF TUKWILA APPROVED AUG 2 1 1937 NILD RECEIVED OF TUKWiLA PERMIT CENTER REVISION PER BUIL DINS DEPT. LE!!tR 8 -5 -G7 PER PUBLIC WORKS LE I I tR 8 -7 -97 Project client FUJI TruColor 770 ANDOVER PARK E. TUKWILA, WASHINGTON FUJI TruColor TTO ANDOVER PARK E. TUKWILA, WASH. ee Descrip ion ELECTRICAL PLAN EQUIPMENT SCHEDULE EQUIP.* EQUIPMENT DESCRIPTION BRAND QUANTITY VOLTS AMPS PHASE ISOLATED &ROUND ISOLATED CIRCUIT COMMENTS WET PROCESS EQUIPMENT I CF- 10/140 C41 FILM PROCESSING HOSTERT 2 208/4 WIRE 125 3 2 RP -108 -251 GE RA PAPER PROCESSING- HOSTERT 2 208 /4 WIRE 110 3 3 FUJI 3008 SYSTEM -3008 FILM PROCESSOR FUJI I 208 22 I Y Y 3A MAGNETIC PIMP * 3008 IWAKI MAGNETIC PUMP IWAKI 1 I20 .40 N N 4 FUJI 3008 SYSTEM-WA 298 PRINTER/PROCESSOR FUJI 2 208 18 i 1 Y 4A MAGNETIC PUMP • SPA 298 IWAKI MAGNETIC PUMP IWAKI 2 120 A8 N N 5 YE .120 ENLARGER FUJI 2 2C£ 35 I Y Y 5A MAGNETIC PUMP • 120 IWAKI MAGNETIC PUMP IWAKI 2 120 ! �8 N N DRY PROCESS EQUIPMENT 6 110 DAYLIGHT SPLICNG GRETAG I 120 6 N N 1 SENTRA 350 SPLICING GRETAG 1 120 6 N Y 8 3000 NOTCHING GRETAG 2 120 5 Y Y 9 SENTRA PRNTNG GRETAG 4 200/4 WIRE 20 3 Y - 10 40K PACKAGING GRETAG 4 120 6 Y Y If 2800 FILM CUTTER GRETAG 4 120 6 Y Y 12 SYNTRA AUTO PACKER 600 PACKAGING GRETAG 6 120 10 Y Y 13 VERTICAL 110 INSPECTION SIEMENS 2 120 8 N N 14 TERMINAL • 600 S PRICING GBI 6 120 3 Y Y 15 URS TAMING GRETAG 2 120 25 Y Y 16 81O -QC ■OGM DENSITOMETER X -RITE I 120 4 Y N 11 DT 200 DETACHER FUJI 1 120 lb N N 18 AT 200 REATTACHER FUJI I 120 lb N N CHEMICAL MANAGEMENT 19 HALLMARK HRC FX 6020/604G SILVER RECOVERY HALLMARK 3 208 30 1 N N 20 MIXER CHEMICAL MIX 3 120 3 N N UTILITY 21 AIR COMPRESSOR -'CL -3055 25 HP COMP -AIR 2 480 60 3 N N 22 AIR DRYER VAN-41R 1 120 19.9 I N Y 23 ULTRASONIC RACK CLEANING PHOTOSONIC I N N 24 GAS HOT WATER TANK 399,000 BTU 1 5TC -400 AO, SMITH 2 120 N N 25 BATTERY CHARGER FUJI I 480 20 3 N N drawn by JR.S check by LSB scale date AS SHOWN - 1 -25- fl discipline I lob number TI-F4 Sheet Number E_2 2 _af.o 3 FUJI TruGolor ?7O ANDOVER PARK EAST TUKWILA, WASHINGTON EOU I PMENT SCHEDULE ELECTRICAL TRAPEZE DETAIL SCALE I" = I' RECEWED CITY OF TUKWI.A PERMIT CENTER client FUJI TruGolor 110 ANDOVER PARK E. TUKWILA, WASHINGTON Project FUJI TruGolor 110 ANDOVER PARK E. TUKr yILA, WASH. Sheet Description EQUIPMENT SCHEDULE REMARKS: CONNECTED LOAD: KVA. ' AMPS . DEMAND LOAD: KVA AMPS �J�y�Vl =1 W 41s-42Jb 27 24 W N. -E,I i W° --IN W 1 NO. LOCATION 5-3 SERVING: !SAGE PANEL SCHEDULE REMARKS: !CONNECTED LOAD: KVA AMPS !DEMAND LOAD: KVA AMPS I HOT HATER ai gi MI 1 CHEtL ROOM LIGHTS [ 1 SILVER RECOVERY 9 I SILVER RECOVEZY 1 g I -i -i -i rrr TTI N h_ I LOAD DESCRIPTION TABBING ))))) ))) NO. I LOCATION 120/208 VOLTS 3 PHASE 4 WIRE N -2 I SERVING: 600 AMP )))))))))))) 0 0 0 ) POLES ; 00000 ' 2T1/480 VOLTS 3 PHASE 4 WIRE 600 AMP ) , ) , ) ) I ) I ) ) I ) , ) I ) , ) , ) , } -) , ) , ) , ) ) ; )--) .1" 4 '/ ') ) )) ) )))'/ TRIP AMPS 1 2O )))) 120/208 VOLTS 3 PHASE 4 WIRE 600 AMP 120/208 VOLTS 3 PHASE 4 WIRE 200 AMP ,),),),),) , ),),),),),),),),),),),),),),),) LOAD DESCRIPTION !POLES ENLARGER I 2 60 72C I 30 20 20 3 30 1 , 20 O O TRIP AMPS W W W W W W to cu POLES 1POLES POLES', COMPRESSOR I PRINTING HVAG *6 PRINTING PRINTING HVAC .4 HVAG It3 SPLICING SPLICING SPLICING SPLICING LOAD DESCRIPTION '.. i t 8 6" N0 CP6 n) ^)z°0 IS IS 20 22 24 26 28 30 32 34 >NO" 0 'tl 1 J / ) ' ) ) ' ) ' ) ') ') ) ) ' ) 1 ) ) ) ') . N.q 9 REMARKS. !CONNECTED LOAD: KVA AMPS !DEMAND LOAD: KVA AMPS �J�y�Vl =1 W 41s-42Jb 27 24 W N. -E,I i W° --IN W 1 NO. P LOCATION 5-2 sERviNS !SAGE PANEL SCHEDULE REMARKS: !CONNECTED LOAD: KVA AMPS !DEMAND LOAD: KVA AMPS I HOT HATER ai gi MI 1 CHEtL ROOM LIGHTS [ 1 SILVER RECOVERY 9 I SILVER RECOVEZY 1 g I -i -i -i rrr TTI N h_ n ))))) ))) NO. I LOCATION 120/208 VOLTS 3 PHASE 4 WIRE N -2 I SERVING: 600 AMP )))))))))))) 0 0 0 ) POLES ; 00000 ' 2T1/480 VOLTS 3 PHASE 4 WIRE 600 AMP ) , ) , ) ) I ) I ) ) I ) , ) I ) , ) , ) , } -) , ) , ) , ) ) ; )--) .1" 4 '/ ') ) )) ) )))'/ ') ))))'/ / ___.. =_t# ._ _ i= 120/208 VOLTS 3 PHASE 4 WIRE 600 AMP ,) ,) ,) )7)--,) ,) ,) ,) ,) ,) ,) ,) ,) ,) ,) ,) ,) , --) ENLARGER I 2 LOAD DESCRIPTION !POLES ENLARGER I 2 60 72C I 30 20 20 3 30 1 , TRIP AMPS 30 TRIP AMPS W W W W W W W to cu POLES 1POLES COMPRESSOR I PRINTING HVAG *6 PRINTING PRINTING HVAC .4 HVAG It3 LOAD DESCRIPTION I-IVAC #2 LOAD DESCRIPTION N$O> i t 8 6" WUI W WNN 0P5` NNUq'(,4NO0'0'?N 0 'tl 1 J / ) ' ) ) ' ) ' ) ') ') ) ) ' ) 1 ) ) ) ') . 07C ZC, 1 250 AMP TO TRANSFORMER CONNECT LOAD: KVA AMPS DEMAND LOAD: KVA AMPS -+-T =1 W WtoA 27 24 40 u.-mu, aNW = d0w- "' TjS NO. ° VOCATION 2T1/480 VOLTS 3 PHASE 4 WIRE 5-I SERVING: 600 AMP ACE PANEL SCHEDULE REMARKS: !CONNECTED LOAD: KVA AMPS !DEMAND LOAD: KVA AMPS - 41 [ TASK LIGHTING I k I TASK LEIEflED { TASK LIGHTRIG -i -i -i rrr TTI N h_ 6 ))))) ))) NO. I LOCATION 120/208 VOLTS 3 PHASE 4 WIRE N -2 I SERVING: 600 AMP )))))))))))) 0 0 0 ) I P°I�I ' 2T1/480 VOLTS 3 PHASE 4 WIRE 600 AMP ) , ) , ) ) I ) I ) ) I ) , ) I ) , ) , ) , } -) , ) , ) , ) ) ; )--) 00 20 20 20 PACKAGING/FILM CUTTER .4 PACKAGING/FILM GUTTER #4 TRIP AMPS 20 j �) ) ) I ) I 1 1 I ) 1 I I ) � ) 1 I I I) n ! / ___.. =_t# ._ _ i= ,) , ) ,) ,) I ) ,) ,) ,) ,) ,) ,) ,) ,) ,) , ) , ) ,) ,) ,) I ) , ) I I PRINTER / PROCESSOR 1 2 I ENLARGER I 2 LOAD DESCRIPTION !POLES ENLARGER I 2 60 30 30 3 30 1 , TRIP AMPS 30 W W W W W W to POLES HVAG #1 COMPRESSOR HVAG *6 HVAG It5 NO HVAC .4 HVAG It3 LOAD DESCRIPTION I-IVAC #2 ""O� N$O> 4ANOO 24 26 20 0P5` ?NOCAO 0 'tl 1 J / ) ' ) ) ' ) ' ) ') ') ) ) ' ) 1 ) ) ) ') . 07C REMARKS: 250 AMP SUBFEED TO TRANSFORMER CONNECTED LOAD: KVA AMPS DEMAND LOAD: KVA AMPS -+-T Vwi1W11 4i2 27 24 40 N9� aNW = "' "' NO. LOCATION N -I SERVING: (SURFACE PANEL SCHEDULE REMARKS: !CONNECTED LOAD: KVA AMPS !DEMAND LOAD: KVA AMPS - 41 [ ( 23 N-o -i -i -i rrr TTI N h_ g P, A O z ))))) ))) NO. I LOCATION 120/208 VOLTS 3 PHASE 4 WIRE N -2 I SERVING: 600 AMP )))))))))))) 0 0 0 ) ro O t . LOAD DESCRIPTION 2T1/480 VOLTS 3 PHASE 4 WIRE 600 AMP ) , ) , ) ) I ) I ) ) I ) , ) I ) , ) , ) , } -) , ) , ) , ) ) ; )--) PACKAGING/FILM CUTTER *4 PACKAGING/FILM CUTTER .4 PACKAGING/FILM GUTTER #4 PAGKAGIN6/FILM CUTTER .21 PACKAGIN6/FILM CUTTER .31 PACKAGING/FILM CUTTER .11 1 1RINTER / PROCESSOR PRINTER / PROCESSOR I I PRINTER / PROCESSOR 1 2 I ENLARGER I 2 LOAD DESCRIPTION !POLES ENLARGER I 2 60 W W W POLES to to HVAG #1 COMPRESSOR LOAD DESCRIPTION NO IMOMNO" 20 ""O� 0O REMARKS: CONNECTED LOAD: KVA AMPS DEMAND LOAD: KVA AMPS I . � 35 37 4i2 27 24 23 N9� ncu— NO. LOCATION 120/208 VOLTS 3 PHASE 4 WIRE N -3 SERVING: 200 AMP J SURFACE PANEL SCHEDULE REMARKS: !CONNECTED LOAD: KVA AMPS !DEMAND LOAD: KVA AMPS - 41 [ ( 23 N-o r � —O� NO. I LOCATION 120/208 VOLTS 3 PHASE 4 WIRE N -2 I SERVING: 600 AMP SURFACE PANEL SCHEDULE LOAD DESCRIPTION PACKAGING/FILM CUTTER *4 PACKAGING/FILM CUTTER .4 PACKAGING/FILM GUTTER #4 PAGKAGIN6/FILM CUTTER .21 PACKAGIN6/FILM CUTTER .31 PACKAGING/FILM CUTTER .11 1 1RINTER / PROCESSOR PRINTER / PROCESSOR I I PRINTER / PROCESSOR 1 2 I ENLARGER I 2 LOAD DESCRIPTION !POLES ENLARGER I 2 r-Pn to to TRIP AMPS 20 0O 20 30 30 30 t 0 'tl 1 J / ) ' ) ) ' ) ' ) ') ') ) ) ' ) 1 ) ) ) ') . ) ) ) ) ) ) ) ' ) ) ) ) ) ' M M MOM •ii_i_ MEI _ii__wii_ iii_ _=iii_ ,),),),) ),),),) ) ) ) ),) ) ) ) ) ) )—) ) ) ) ) D 20 00 20 00000 20 20 20 200 p� -- — — N� — _ — — — POLES 3 —m_ LOAD DESCRIPTION DARKROOM / MAINT. LIGHTS MAINT. OUTLETS MAINT. OUTLETS INSPECTION HVAC PACKAGING 4 PRICING *6 !HVAG 1 PACKAGING 4 PRICING *4 PACKAGING 4 PRICING *5 [PACKAGING 4 PRICING 1*2 'PACKAGING 4 PRICING *3 I PACKAGING 4 PRICING UI RA PAPER PROCESSING s2 . LOAD DESCRIPTION RA PAPER PROCESSING .1 A A NOCPO`ANO W W W W W N CPO` IJ N -pN N N - N O . N O 7C A N W W CDO`�PNQ W W �! N pi 124 126 N N NO Oj O � :F. N Q .4 N n �� D90-0z4 77COL r2� Apn Oo A z> zrn /. o3sz Lon, LoozailsU 702 Broadway Suite 102 Tacon , Washington 98402 '$h. (206) 274 -.0244 • Commercial and Residential Design