HomeMy WebLinkAboutPermit D97-0337 - CONDON JOHNSON INC - WALLSCity of Tukwila (e9ted I (206)431 -3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 WARNING: Parcel No: 022330 -0020 Address: 651 STRANDER BL Suite No: Location: Category: AOFF Type: DEVPERM Zoning: CM Const Type: Gas /Elec. Units: 001 Setbacks: North: Water: TUKWILA Wetlands: Contractor License.N KR345W Permit Center Authorized Signature: DEVELOPMENT PERMIT IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES, APPLICANT IS PROCEEDING AT THEIR OWN RISK. .0 South: .0.... Sevier: TUKWILA Scopes: N Print Name:/(4.4„05 Permit No: Status: Issued: Expires: Occupancy: OFFICE UBC: 1994 Fire Protection: AUTO FIRE ALARM East: .0 West: .0 Streams: 097 -0337 ISSUED 11/19/1997 10/24/1998 OCCUPANT CONDON - JOHNSON INC 651 STRANDER BL, TUKWILA WA 98188 OWNER KOLL BUSINESS CENTER C/O KOLL MNGT SERVICES INC, 19515 N CREEK PKWY #214, BOTHELL WA CONTACT MIKE SEDWICK Phone::206 575 -0765 ,631 STRANDER BL #6, TUKWILA WA 98188 *•k ****•k *•k *•k * * **** ** k* * *•k * ** k *•k * *** *** * * *•k ** k * * *** * *** * * * *•k *** k *•k * **** * *** * *•k k•k* 1 Permit Description: TENANT: - IMPROVEMENT - CONSTRUCTION OF NEW WALLS IN OFFICE BUILDING. ************ k************************* k************* k**** * * * * ** *•k* * * **** * * * *•k *•k *kk** Construction Valuation: $ 15,000.00 PUBLIC WORKS PERMITS : *(Water Meter Permits Listed Separate) Eng. Appr: Curb Cut /Access /Sidewalk /CSS: N Fire Loop Hydrant: N No: Size(in) .00 Flood Control Zone: N Hauling: N Start Time End Time Land Altering: N Cut: :Fill: Landscape Irrigation: N Moving Oversized Load: N Start .Time: End Time: Sanitary Side Sewer: N No: Sewer Main Extension: N Private: N Public: N Storm Drainage: N Street Use: N Water. Main. Extension: N Private: N Public: N ** k***************** * ** * * * *•k * * * * * * * * * ** * * * * * * *•k* k * * * ** * * * *•k * *** ** k * * ** * *•k * * * * * * * * ** k TOTAL DEVELOPMENT PERMIT FEES: $ 417.34 * k* ** k * * * *•k * * * * * * *•k * * * *•k k* * * ** k * *•k * *•k * * *•k * *•k * * * * * * * * * * ** k* k k * * * * * *•k* k ** ** k* k *•k * ** k k * '; 6 Q / c.,k_ Date: I --DC2-- Dian I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this development rmit. Date:/ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. tl City of Tukwila L WARNING: Parcel No: 022330 -0020 Address: 651 STRANDER BL Suite No: Location: Category: Type: Zoning: Const Type: Gas /Elec.: Units: Setbacks: Water: Wetlands: Signature: Print Name: AOFF DEVPERM CM 001 North: TUKWILA Contractor License No: KR345W Construction Valuation: $ PUBLIC WORKS PERMITS: *(Water Curb Cut /Access /Sidewalk /CSS: Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversized Load: Sanitary Side Sewer: Sewer Main Extension: The granting of this permit cancel the provision of any or the performance of work. development permit. Fire .0 South: .0 East: Sewer: TUKWILA Slopes: N TOTAL DEVELOPMENT PERMIT FEES: $ i*********** * * * * * * * * * * * * *. * * * * * * * * * * * * * * * ** Permit Center Authorized Signature:_ I 12,000.00 Meter Permits Listed N N No: N N Start Time: N Cut: N N Start Time: N No: N Private: Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 DEVELOPMENT PERMIT IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES, APPLICANT IS PROCEEDING AT THEIR OWN RISK. Permit No: Status: Issued: Expires: Occupancy: UBC: Protection: .0 West: Streams: (206) 431 -3670 D97 -0337 ISSUED 11/19/1997 05/18/1998 OFFICE 1994 AUTO FIRE ALARM .0 OCCUPANT CONDON - JOHNSON INC 651,STRANDER BL, TUKWILA WA 98188 OWNER KOLL BUSINESS CENTER C/O KOLL MNGT SERVICES INC, 19515 N CREEK PKWY #214,BOTHELL WA CONTACT MIKE SEDWICK . 631 STRANDER BL #6, TUKWILA WA 98188 ***************************************************** * * * * * * * * * * * * * * * * ** * * * * * * * * * *** Permit Description: TENANT IMPROVEMENT- CONSTRUCTION OF NEW WALLS IN OFFICE BUILDING. •**************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Phone: 206 :575 -0765 Separate) Eng. Appr: Size(in): .00 End Time: Fill: End Time: Public: N Storm Drainage: N Street Use: N Water Main Extension: N Private: N Public: N r********************************************* * * * * * * * * ** * * * * * * * * * * * * * * * * * * * ** 313.46 * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** L Date/1=19=7J_ I hereby certify that I have read and examined his permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. does not presume to give authority to violate or other state or local laws regulating construction I am authorized to sign for and obtain this 01_ Date: __`L 4 'f/ 1 ? This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Project Name/Tenant: CONS' 0N-SDi-INsoN i 1NG. Vale of Construction: JV1Z Site Address: , State /Zip: 051 sTKA AID eg, 8L0V'.1) .11)14- WA, 4 181 SS + 9)010 Tax Parcel Number: O 2 33 Q - ooze' Property Owner: PACT P IG GULF PROPE.tr /ES , /Az . Phone: ZOb Fax #: 6 575 074,6 .5 S- X70 Street Address: City State/Zip: /a 3 I $TRArvPee 2341/). #G T VY1.11/1.1- 1.129 gm Contractor: 5C g FO IeM ti- 4 Phone: in the building? ❑ yes 61 no X 11 paper indicating quantities & Material Safety Data Sheets Street Address: City State/Zip: Fax #: Architect: Ni /! ` / Phone: Street Address: City State /Zip: Fax #: Engineer: N Phone: Street Address: City State /Zip: Fax #: Contact Person: HIVE Sepu} t rY . - it ` -7 Phone: 24/ S75-0765 Street Address: City State/Zip: 31 STIzANDE k aLolt6 TV 4A1 Fax #: 57S D 7c2 f Description of work to be done: GO>u zu - aiJ 0E- KE,LAI IAMu,5 I iS t ffi 66 E:6 - • CoDE &ECr /C L Existing use: El Retail El Restaurant Cl Multi- famil El Warehouse ❑Hospital El Church El Manufacturing ❑ MoteVHotel El Office El School /College /University El Other Proposed use: El Retail El Restaurant El Multi- family El Warehouse El Hospital ❑ Church ❑ Manufacturing El MoteVHotel - Office El School /College /University El Other Will there be a change of use? El yes fl no If yes, extent of change: (Attach additional sheet if necessary) Will there be rack storage? El yes 171 no Existing fire protection features: Cl sprinklers 71. automatic fire alarm ❑ none El other (specify) Building Square Feet: l Q r 4 existing Area of Construction: (sq. ft.) 1 4-6 - 0E) Will there be storage of flammable /combustible hazardous material Attach list of materials and storage location on separate 8 1/2 in the building? ❑ yes 61 no X 11 paper indicating quantities & Material Safety Data Sheets CITY OF TUf'WILA Permit Center 6300 Southcenter Blvd., Suite 100, Tukwila, WA 98188 (206) 431 -3670 Commercial / Multi - Family Tenant Improvement / Alteration Permit Application Application and plans must be complete In order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. ❑ Channelization /Striping ❑ Curb cut/Access /Sidewalk El Fire Loop /Hydrant (main to vault) #• Size(s): ❑ Land Altering 0 Cut cubic yds. 0 Fill cubic yds. El Sanitary Side Sewer #: ❑ Sewer Main Extension El Storm Drainage ❑ Street Use El Water Main Extension El Water Meter /Exempt #: Size(s): 0 Deduct ❑ Water Meter /Permanent # Size(s): El Water Meter Temp # Size(s): Est. quantity: gal Cl Miscellaneous APPLICANT REQUEST FOR PUBLIC WORKS,SITE/CIVIL PLAN REVIEW:OF.THE:F,OLLOWING : : %. (Additional reviews may be determined .by tlie'P. ubllc Works Department) Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date application acce ed: j o -I ff 14- t7 Date appllcafipn Appl at ten by: (Initials) PLEASE SIGN BACK OF APPLICATION FORM CTPERMIT.DOC 1/29/97 FOR STAFF USE ONLY ❑ Flood Control Zone El Hauling El Landscape Irrigation O Private 0 Public O Private 0 Public 0 Water Only Schedule: BUILDING OWNER OR AUTHORIZED AGENT: Signature: / 46; . , / 4 `' Date: Iof ( r l4 `' j- 6 ` : Printname�- MlCbl t11'El_ 5 iC O S 7S•07(�� - s' O Address ( ( 5T,{z 1'L T3L V City /State /Zip. K ^ L AC ALL COMMERCIAUMULTI -FA TENANT IMPROVEMENT /ALT' TION PERMIT APPLICATIONS MU SE SUBMITTED WITH THE FOLL • ING: ➢ ALL DRAWINGS TO BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT, STRUCTURAL ENGINEER OR CIVIL ENGINEER • ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN ▪ BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A SUBMITTED ❑ ® Complete Legal Description El ❑ Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures (Form H -13). Business Declaration required (Form H-10). Four (4) sets of working drawings (five(5) sets for structural work), which include : ❑ 71 Site Plan (including existing fire hydrant location(s) 1. North arrow and scale 2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements 3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions 4. Location of driveways, parking, loading & service areas 5. Recycle collection location and area calculations (change of use only) 6. Location and screening of outdoor storage (change of use only) 7. Limits of clearing /grading with existing and proposed topography at 2' intervals extending 5' beyond property's boundaries 8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of use only) 9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of those, identify by size and species which are to be removed and saved 10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change of use only) 11. Location and gross floor area of existing structure with dimensions and setback 12. Lowest finished floor elevation (if in flood control zone) 13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form H- 9). ❑ ❑ Floor plan: show location of tenant space with proposed use of each room labeled ❑ ❑ Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of any hazardous materials; dimensions of proposed tenant space. El ❑ Vicinity Map showing location of site ❑ ❑ Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of rack. Structural calculations are required for rack storage eight feet and over. El ❑ Indicate proposed construction of tenant space or addition and walls being demolished ❑ ❑ Construction details ❑ ❑ Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of water supply to sprinkler vault with documentation from contractor stating supply line will meet or exceed sprinkler system design criteria as identified by the Fire Department. ❑ El Washington State Non - Residential Energy Code Data shall be noted on the construction drawings. ❑ ❑ SEPA Checklist - if intensification of use (check with Planning Department for thresholds). ❑ ❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other land use or SEPA decisions. ❑ ❑ Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County Department of Public Health prior to submitting for building permit application. The Department of Public Health is located at 201 Smith Tower, Seattle, WA or call (206) 296 -4787. (Form 1-1-5) ❑ ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no contractor has been selected at time of application a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as pad of this submittal I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. CTPERMIT.DOC 1/29/97 CITY OF TUf,WILA A "+ dr`ess 6$1 STRANDER``BL Permit No: 097 0337 Su Tenant Statu ISSUED Type DEVPERM Applied 1•0/14/1997, Parcel i!. 0:22330 .0020 Issue 11 / 19./ 1997 • i AAAAA ; ***' Ak:.A A'A A**'* A* AA*:' AA AA**** kA' A' A' k' AA` k *A•k *k*A "'k *'A*'AA' * *'kk AA''k * ** ** *. *SAX *: ** permit :Conditions 1. ,No changes' Zvi 11 be. made, to the n plas s v unles approved by the Eng ineer and t he Tu Buildin.gf0i:v:isior� 1` ec!r,ical•• permits shall .,: e:4bta° filet .thr•o'u,gh the Washington of :Labo " `and ; T ; r7'dustr:i ens es and.al:1 ei'ee;trica -l. t i a u. y t en a gcy (24,83 b63 work • 11 ° be ted t} tha All permits,Erinspectjian re�ccrds,'and approved ilansw- ,shall ova i 1:ab l e` pct +;;the 7`'0 s i 4e 'p r =i'ar: i a 3the sitar t' of ar'.y oon= structiaiy:4: t e se`.docume in and t :av ab;la untl1r °`fi : na ?l iinspec� : t'ion,appr ova1`isgranted to , ', All car��,tr to.be. done in can Formance� withy a0pr p l ; rid r, equ� Rreme`nts of the Uniform Build Code r (1997�' i•ti ',or) as amended, Ut�fi:fth m Mechanical Cade ( Fdit ). a h of on :Sta Energv- Code/(19 Edition)' ; ' 5 1h`e e `sha�l;l' be..no oc uponcy of the buil dings) until final .inspe "fit has, ; been conipleted' by the Tukwila I nspect or.. F :; ;r A , tTTFICATE''OF OCCUPAN(Y bell1. BC ;REQ FOR THIS PERi�IIT V alidity of: Permit The issuanc`& of a. pertini or approval 'a pl }an # s, xspecifications,. -.and computat ions,...shall not :be con shred t + p be ,a permit° for, o an' appraval" o-f; any violation f : ofs ny off, the.`provz,sians l othe `building code or of any M (ther' ord inance of ;the ju rts`dict No permit presuming .t -g,i :' .au,thor to 'via °late or c'ahceli`{ the °pro;v.i ° 'of`)..thi's c.ode''tsha l l " "'be'� l i d fi b ,+ti t .. . �'� '. f L`�`. " . n I -TY: OF TUf WlL; d..r °e s •u •i Ten 5tatu T'SSUEC1 s GCVFE Ap p i i ed l 0 / 'arcel # 022330; Issued 11/19/1997 'k •k •k k. k k'•,k' k k k k k * k * •k k k * •kk k •k •k •A,k y 4 k 1k 4 *4 1, *444 'ermit Cand lo; changes i wi 1 1 be. made - to. `the .P lans un.l ess •:approved b r chitect a "r Engineer a n'd the Tuk•wi la- Bt. ;i ►ig ,Di•vis ion 1:ectr: ;ical .'permits hal:J he obtai`ne.d. th dugtr M1 the Wash ington fate Division 'ot •L bor. and Industries anti Yal i° el rq k wil l be i nspe a cved b.y that agency (248 t f3'tl3 " 1 "`l permits, ,i pectian r ��ord � and appr oved plansi shall b vaitabl a the ,job sIt.e prior to the st rt,of ariy sari • tr uct, an t.2ti� ,The do c ument s a re ;.to be maim >in ed and able anti 1 final, irispeot;i,an appr oval rIs qr anted �� .- ; X11 c.,onstr t�o -clone in ;conformance witha appr -laps, a tdr requl'*entents of the` Unlfo,r�m Bui idin`g. Code 4 01994 �� diti t a; amended, Unife rm Mecha'ni. al ode • (1 94'rEdai ��at S • f F ;� h u k . . n : d Was ington 'State Energy 'Code (1994 Ec1.l,tioriJ . ti , �'hik. h r hail; be: no ao, c of tie bu:i ldingt SJ ant i 1 the r i:na'1 inape.4, ian has been completed, by the T uk•wi la`,B n s ✓ p.�e t a r} f k1 1 � DES 1. ,. -t . ILL 0004 t o r i .a d .. 7s`.i 5 -t{. Sv c {. • •CER OF OCCUPANCY 4J BE ,RE UI EO FOR THIS T 'a:l' d l ty gt Feuer m it' The; iYs uan'ce of is e r �p rm,i t . ar arr o va A• 7� 4 1 pp •pe ;a co ahal l • not be4� stmt ; d to b,e a p r;m'.it � tor , or p an app of, any ol viti ct,i..p t �k� ot of rt.he �prov i:s i ons of •the bu i ing code 'or4 of zany othe r ar d i nonce, ot, .,the ur, sd i N r' .per mi t presum ng to l I • • gi:v 1autharitvy to vialat'e ar can er'l t;he • pr o visions. of his c.orie Ott - ill v.be w�1 iti. r i gw • ay e�r n i;t N,o G.J7 -;033 • k **,‘ • * **It:* , ?v ir 4( „ „ • . ,„ , .• • TR 1.48 • tic , ,c , *::1! , 4.. .A * * **ft** ;* R70067 : mal.t 110 , 11 /97 :I. Natation ..T .1 ''.'DEVE,I....0?1 PER 14.I Perinit . ;Feet': : 313 . • .•.• .„ . . , •"„ • . • • 121 lj rotal LL Prnt 121 71 •-• '*.****-**A*.***i;v1, • ''.11 caut Coda P s6 tar1 in�un 000/345 830 PLAN CHEC NONIIEP ' 121 L rk ti , k ,{• 4 * "k. A ' **I *lc:** /tic' t dt 4 ! 4s. c. .k .* • . •k" •k . A k k .k. k A �c :+F A k S * *1 • CITY OF TU,K l A » W ` , TRANSMIT' AA AA* 14',*.A•' #•kk•kA *7h.k*: * it A ok7 �Ak.k �k4k *k.•1**•k1h**,1Ak **l*kk�k; • f AN Number: R9.7 00b87 ' A_maiir<t; 1:03.8 3 .1/04/97 '15 ::08' Payment Method :•„ CHLCK":- Nat'a4i'an: PAGI1 IC, Init:•••WA13 Permit No: ..D3770337 Type; •DCVPLUM DEVELOPMI:N•f PERMIT Parcel Not "02 2330- •0 0 20. . "a ite: Address 651 ,.STRAtl)ER `IlL Bpi .ance .017 ,•* *•k *AAA4* AA.A "•k *AA k^ 42'.• kA 1 A. 1k• k dit*** d*• k{ •A•kA•A.A:!A *1,•4Ah•kdfir.3 •kdrA7kttRk *A *•k Account Code 00.0/322.100 0.00/345.83.0'. Total Fees; 41.7_.34 Total ALL Pints: 417.34' Descript.ian fU3:L0IN6 - NONRES • PLAN. CHECK NONR Amount 37.50 .. • � .�: }� <.. A;iAA,4.* A *;*3 k *A +3'. * *isAit#* * *• *A *a * 4'ka - A * A.►'A•,- I.. *;t * ' A. :A A A *t * #A4 A. *:a*c9 G I • tY qh 7UKL�ILA.. WA ritA l ** *'a-: *A * *;7i -A *1 *:Asp * * :a* ti *A * iS5 h .3 •A '* *It* * *•� * * *t% *** *A*1 ** TRANSMIT Num btr• 89700661 ''Amount: 191,7;, /97 13 :47 Payment Method CHECK tiotdtior►: 'MiCHAL`5EDw]cK 'nit:. NAB Permit,;No. - :097--0337 ' Type; DEVPERM .DEVELOPMENT. .PERMIT' Parc.el No :' 0'1"330.-00',0 ite''Addr eas:;'.651 ST'RANDLR Total Fees: .. 313.46 This Payment. 191.75 Tuta1. ALL Pmts.: . 313.46 Balance: ,00 3 * **9' **A 9 ; ** ** ** ,1 * . * * ** * * . * * * * ,t{ ** * * ** * * * * *4 *** * * * A-4 *A * *a. ** Account;. Code Descr;1 pt i on Amount 000/322.100 BUILDING - NONRE5 187.25 ' - 000/38G ` .904 STATE BUILDI SURCHARGE 4,,50 Proj t: k. 6hC U1' �vhwsOti. Type of Inspecti 1 „t I rest ivc c(er Date called: 1 -,)..to-,2000 Spe in C t�. - '5- 0. V, . S . �p V vv vti" Date wanted: ��� - 01 'p'e Requester. a v Phone: _ to ► • ui�«:�. 4• �:+'vio't;!k�icri'4t 9 i.. INSPECTION RECORD Retain a copy with permit INSPECT! O. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 9818 PERMIT NO. 431 -3670 Approved per applicable codes. $47.00 REINSPECTION F EQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: Corrections required prior to approval. Project , �(' / C 0$'707-1 Type of inspection: /---- Address: / 5- / � / Date called: Special instructions: / C' / 0 , oo r"', ( Date wanted: L . 7 7 pm. Requester: j Phone No - 650 -6/77S INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 COMMENTS: I h frVr k%, e_ 4, AA croo $ 73, R4,44 c... 174.r 5 1121 4,e . e./ Approved per applicable codes. Inspector: .. INSPECTION RECORD Retain a copy with permit P MIT NO. (206) 431 -3670 Corrections required prior to approval. 4� • tootAi i Date: 1-/-27-le _I $42.00 REINSPECT! N FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspectlon. f Receipt No.: Date: -Project: GaNDbr4 J-e 1-4-145-zr:..1 Type of inspectioir- ra-mivEr ),4I Address: , ( 3/ 377z-h-NUAZIT-- Date called: ' Special instructions: e-Et.-ritzew, c.oemti-47,./\, Date wanted: . 2-9 Requester: Phone No.: • INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Sduthcenter Blvd., #100, Tukwila, WA 98188 pproved per applicable codes. COMMENTS: Inspector: I Receipt No.: wswybos.10.413igatanatetteattatZrageEM .■■•■•1014 INSPECTION RECORD Retain a copy with permit h eec> 1 --- r //4 e -/e I -Le, / 6/ .. )1 PERMIT NO. (206) 431-3670 Corrections required prior to.approval. Date: $42.0C REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., 100. Call to schedule reinspection. Date: INSPECTION RECORD Retain a copy with permit INS'ECTIONNO... CITY OF TUKWILA BUILDING DIVISION , 6300 Southcenter Blvd., #100, Tukwila, WA 98188 COMMENTS: Date: PERMIT NO. (206) 431 -3670 Project: t i Type of impactio �ClV1G1�/11 . � f1.`�C/1rL a r 1 ci Addre s Date called: J w lam(. 1.....›? 9 Special instructions: = Date wanted: �-- . , a.m Requester: � I Phone No.: 5 •1 ! S'o . /%S Corrections required prior to approval. I Inspector: 11 I Receipt No.: -96) $42.00 FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Blvd., Suite 100. Call to schedule.reinspection. • Date: INSPECTION RECORD Retain a copy with permit INSPEC N NO. CITY OF TUKWILA BUILDING DIVISION '6300 Southcenter Blvd., #100, Tukwila, WA 98188 Project: e :Addre 4ci/r/612 gitA Special instructions: 14.(Xaj Type of ection: % Date called: Date wanted: )2L (0-7 a.m. Requester: - p c L. L1 Phone No.: — 790-3 ( -1 - 71 . Approved per applicable codes. Corrections required prior to.approVal.: 'COMMENTS: .... • . • . • A4 1 Date: /-2 / $42.00 REIN PECTION E REQUIRED. . Prior to inspection, fee mutt be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: PERMIT NO. (206) 431-3670 • INSPECTION RECORD Retain a copy with permit INSPECTION NO. . •. CITY OF TUKWILA BUILDING DIVISION '6300 Southcenter Blvd, #100, Tukwila, WA 98188 'w PERMIT NO. Type Inspectio4n: , . VIt t OttiV l I I Date called: ( 11 8' 9 Date wanted: Phone No.: Corrections required prior to approval:. fi7�u't h Inspector: $42.0b REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection, Receipt No.: Date: Date: .,,,' INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY- OF TUKWILA BUILDING. DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 h&toh D k fr Addre S Special instructions: Approved per applicable codes. Type of inspectio Date called: (./( 1 ` Date wanted: . z l (z l Requester 0 1 Phone No.: 20(f - 1 G 1 c 3 41 ! Corrections required prior to approval. . COMMENTS: Receipt No.: Date: (206) 431 -3670 sal _d4t $42.00 REINSPECTIO FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. • CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Project' INSPECTION RECORD Retain a copy with permit Type of inspection; ate called: Phone No.: PERMIT NO. (206) 431 -3670 Corrections required prior to approval.... Inspector: Date: /'^t 4 / 46 $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd„ Suite 100., Call to schedule reinspection. I Receipt No.: ti Date: Project: t _ Type of inspection: Address LOS/ ������ called: 1 - 16-9 ri Date wanted: 1 ---) . a: rr p.m Special instructions: Requester: p ja i Phone No.: ' :'n: Y{,• e',4-' '4: ;.:li�•in'!i. {w.'k Cfj.r.:: PERMIT NO. INSPECTION RECORD Retain a copy with permit INSPECTION NO CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, .Tukwila, WA 98188 (206) 431-3670 Approved per applicable codes.: I 141 Corrections required prior to approval. COMMENTS: Inspector: Date: / 2.7.6 .49 ;' $42.00 REINSPECTION E REQUIRED. Prior to inspection, fee must •' ' be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION NO. ,sr CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter. Blvd., #100, Tukwila, WA 98188 Type of inspection Date called: Date wanted: m. Project,; J Address: Special instructions: Approved per applicable codes. Requester: Phone No.: Corrections required prior to approval. MENTS: - 1)1" Cott\o--ti)-,- p Date: 5 REINSPECTION FEE REQUIRED. Prior to ins $42.00 ectl n, fee must b be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: INSPECTION RECORD Retain: a copy with permit Date: PERMIT NO. (206) 431 -3670: Project• ,(91-, —./ )4 h 513"h Type of inspection: . • r 2-,-,r Address: .Ad sS7 ,,5�.- 4 /J/4/ Date called: c6 —97 Special instructions: • Date wanted% a.m p:m• Requester: .Phone No.: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. COMMENTS: INSPECTION RECORD Retain a copy with permit I Ge i Co (ufti DOR - L> eceipt.NQ Date: it PERMIT NO. (206) 431 -3670 Corrections required prior to approval. Inspector: ( Date: ci OA it $42.00 REINSPECTION FEE REQUIRED. Prior to ins actin fee must be paid at 6300 Southcenter Blvd.,' Suite 100. Call to schedule reinspection. Proje Type of inspection: Address: / n6 7Cd.d , } i . I \ �J \.k.: Date called: , 1 -� Special instructions: ' _ lei& 4J. � " . .. .�;,,.;, t . -' r,.ruN k 1,: Date wanted: ' - 1 -' 1 . a.m p.m. Requester: Phone No :: 5 i75 -0765. Receipt No.: INSPEC • NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 9818 COMMENTS: 6 // nage& (7a/ A1 7 s4-�. , �rsaf .�s 476-04 ee.e • Inspector: • Date: f•.. •z,,5 Approved,per applicable codes. INSPECTION RECORD Retain a copy with permit r' Corrections required prior to approval. 14 1 $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: 06) .431 -3670 COMMENTS i -... I I jx z P-- pLI-P ,Bb s wyi mA- 1' pieerwiAg 0 (1..h-t4 t + St&6 - tT P* ( S it) ' ig CArl . (CJVL h-P P M>J h � ll , N 1-1 t R$ P co /WA D bit— ITS 0tn�` • J . "t�' r: 0 1 Oil) EI - tc x t,n a - t 1•• 661 O it— No rs - (L & STR-+ it._. e'►J Li WSu (bc---. jt S CI-1/4.= lhyr Gri- --Pi WI1'4 0017 , 1 4) C5)114-, 44-J (L... W AA..t.S W I L i J' C `�"` 0 -1-p /5C R --•0 tx v' T\ CTS■ CM. ' aT J UST in Cili t_.1 1 i t't' ' G 4'v • 9 p tA I i-AMF ,S- �C - L-- 1 r '1`4-M1 S `134hT N v se..-c.& Ate-. A- - e 41wJ Phone No.: 57S S "'0 Project:/1 ( i -... I I jx Type of inspection: . . rnG- rv�..wv"4 Addre s: / 4p .�? . .K Date called: - I' -G7- Special instructions: Date wanted: ) � � a.m. P.m.. Requester: Phone No.: 57S S "'0 0. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 I Inspector: CT I I Approved per applicable codes. Esc, itU'lxaGte98merovS w i:- INSPECTION RECORD Retain a copy with permit PERMIT NO. (206) 431 -3670 Corrections required prior to approval. Date: /1-1 4c_? $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. I Receipt No.: Date: of P roject Address Retain current inspection schedule ti iP "sua, ?�y rrpv uq 'C Approved without correction notice Sprinklers: Fire Alarm: 5/,,.E -< . greet' P (q ) Hood & Duct: Halon: Monitor: 141 / Pre -Fire: Permits: Approved with correction notice issued Authorized Signat re FINALAPP.FRM .yVyrV4y., �. City of Tukwila John W. Rants, Mayor Fire Department Thomas P. Keefe, Fire Chief TUKWILA FIRE.DEPARTMENT: FINAL APPROVAL` FORM F 6 ' y' r- .. zolt r:':.C; y r f 1\ ":: . f r. f• ro, M'F y v Permit No. D97 T.F.D. Form F.P. 85 /Met? Dat Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 •?hone: (206) 5754404 • Fax (206) .575-4439 0 1 • FL C rP CA L- . 5111 - 15 110 O ) (ZE-f ' i r arl (,3) b%F� GE 0) MAIN rLCo Ek_ PLk N %" -1` RECEIVED CITY OF TUKWILA DEC 0 21997 PERMIT CENTER D — 03S7 w A LLS REx 0\ 1Eb 1— _ _ • • • • 1 1 l l I t 1 OPEN 6 lICC. 11 1 1 PEN L Ft 1 CC • , 1 :� Plan Ctit. s:. • . • .. and- omissions not 1D Violation c :a::_, cd coda or L T Mat of copy cf approved OMB mod. [. C Fl EW baJ - STRU L� OrAL NOTE • N • WALI_s = AP -DITt b 11 L wALL.S P214.0 "V A LL, S 11111111 11111111 I ontzc or's Pemmit NoD — 0337 L[ ORIG1)4AL C. Tr.NAh1T I Ar• G: THE FIRE 1 FoR A >J►va_ FLA NINED LA6E.L.2. D C:►t\YLETE AND Ci.►ar • • E c.) uJ 0 John W. Rants, Mayor ` Steve Lancaster, Director December 20, 1999 Mike Sedwick 631 Strander Bl, #6 Tukwila, WA 98188 Dear Mr. Sedwick: City of Tukwila Department of Community Development Permit Status D97 -0337 651 Strander Bl In reviewing our current permit files, it appears that your permit for a tenant improvement issued on November 19, 1997, has not received a final inspection as of the date of this letter by the City of Tukwila Building Division. Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the building official under the provision of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, if a final inspection is not called for within ten (10) business days from the date of this letter, the Permit Center will close your file and the work completed to date will be considered non - complying and not in conformance with the Uniform Building Cock and /or Mechanical Code. Please contact the Permit Center at (206)431 -3670 if you wish to schedule a final inspection. Thank you for your cooperation in this matter. Sincerely, Lktendx/(4# Brenda Holt Permit Coordinator Xc: Permit File No. D97 -0337 Duane Griffin, Building Official 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • (206) 431-3670 • Fax (206) 41313665 • t • BUILDING DIVISION NOTES • All new doors at Suite 110 shall comp- ly with barrier free code requirements. Minimum net clear opening width shall • be 32 inches with door in any position. Lever latch hardware required per barrier free code, at all new doors. New hallway to be developed at Suite 110, shall provide a minimum net clear width of 36 inches. BUILDING DIVISION NOTES New unisex toilet room shall comply with barrier free code requirements. 1. Unobstructed floor space within the toilet room of sufficient size to inscribe a circle with a diameter not less than 60 inches. 2. A water closet with a minimum 17 inches and a maximum 19 inches N measured to the top of the seat. The lateral distance from the center line of the water closet to the nearest ob- struction, excluding grab bars, shall be 18 inches on one side and not less than 42 inches on the other side. 3. Grab bars shall be installed at one side and at the back of the water clo- set. The top of grab bars shall be not less than 33 inches and not more than 36 inches above and parallel to the floor. Grab bar located at the side shall be a minimum 42 inches in length located not more than 12 inches from the rear wall and extending at least 54 inches from the rear wall. Grab bar located at the shall be a minimum 36 inches in length and shall extend at least 12 inches beyond the center of the water closet toward the side wall and at least 24 inches toward the open side of the water closet. 4. Lavatories and sinks shall be mount- ed with the rim or counter surface no higher than 34 inches above the finished floor. • 97- OS 11606ois • "iorntaiwAvotono,s4401rsif... JN'Pti:7i. alif yn WArk tr %b',MA+?L•Sfell. vA�rola.lCn. Kiw.•AL•NxM Mnww4+• My.;nu,hxw.v+�s«rrstewi.wrvtnM1>. CITY OF TUKWILA Department of Community Development Building Division- Permit Center 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431 -3670 DATE: • \ 6k PLAN CHECK/PERMIT NUMBER: Dq 1 D 3 3 7 PROJECT NAME: COMbOtQ l\1.S l G+ PROJECT ADDRESS: (a 57 5772fri J E _ F3L. t/7 . Za k CONTACT PERSON: Mi SEDWiU PHONE: 76 S REVISION SUMMARY: I. A ONe U1J i S -E ES r re.--oo4l l iJ 0,00 \ b t+AL c. w,4.Y Y /JLA RG //VG sr LNG SrCRA Ge GL- cS 7 GUI- /.5 *E) c � /T 70 Ex G P-00 / 5 a WA CC- 5 /& gx Tla e to! EN At R.E , 1715,5 E W4 LL S f9/2 E �tJO,t/- 7� W� " 'U.ev4 L. W�4 ,64.7,01(1^ E'T A/UJ2 t // /9 ,pp/ T/D w 76 49Zi'- -9-1) ) r7 N D�� . 1 '� - r 3 D l 7' Oki L • L S • (�t•l TD (5PEGS ,4 5 14 17�14 t, S' • 'F x� 011 SHEET NUMBER(S) ! g" "Cloud" or highlight all areas of revisions and date revisions. SUBMITTED TO: 130 5 13E I 1)4 'PEAL / t T' &A� 3o i' e NE w STS' -aD tvt �1 ; DEC i 190 PEFIM It CENTER Gn�t _ CITY USE ONLY .frj Planning Fire RECEIVED CITY OF TUKWILA Public Works 3/19/96 'fu s*le9NcS•rtrY. v, ;!'fX:.".3p1:.:1.:'?l:�. etZi�.T.Y�nV.,^.x.'..TKw. re:VCO M. rentik, ! a.. 9Matomu: B: A+ lx, MrifOtOt tit #.C.V.OIrits4An:I.ltitmsAn's2ivn c CITY OF TUKWILA Department of Community Development Building Division- Permit Center 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431 -3670 REVISION SUBMITTAL . 01-0357 DATE: I L I 4p fq I' PLAN CHECK/PERMIT NUMBER: PROJECT NAME: Condon - Jhno,a) Ic.. PROJECT ADDRESS: (OS 1 311 index t3 CONTACT PERSON: H L 3q• ln2l cJ -- PHONE: 5 07 0 S RECEIVED CITY OF TUKWILA NOI(,0 6 PERMIT CENTER L e Nei - e01 REVISION SUMMARY: / P6ted or 44 4- D itJ PL * - ) - .? . Jt TES NFW ao/eR /Pe/e c & 4/4 CONS ries, cv not/ - 5 E /,✓AL L c5ELT /D N ACT 4J f. 4-hl. 3. AJOT -1? rn L- Pd d r1 S no2Z 0 ? D ,(/ //V ors F/2 r R05/ STi (/E" • �. NOTED p20&s 7 A/ 7 /JSe DF E 1 -f /50c / f/tG6 GJ/1 / ff/95' Two & S. A/ D 4.46 5 /4/6. 4-0C if s 40i7 PEi2- Sd3 - /9000R,D/Al‘ 7• gA /eC 6 y cept NE1,0 L /6Hr /d /5 /I✓ GO/ZIZ/Od /L Jii1Lr • SHEET NUMBER(S) 2 .2 3 "Cloud" or highlight alr areas of revisions and date revisions. SUBMITTED TO: "PQ/t)/ 4 -7v • Bldg. Planning Fire CITY USE ONLY Public Works 3/19/96 October 28, 1997 Dear Mr. Sedwick: Kelcie J. Peterson Permit Coordinator Enclosures File: D97 =0337 ;vTS 4171-1 Gita J� c City of Tukwila Mr. Mike Sedwick 631 Strander Boulevard #6 Tukwila, Washington 98188 Department of Community Development Steve Lancaster, Director SUBJECT: CORRECTION LETTER #1 Development Permit Application Number D97 -0337 Condon Johnson, Inc. 651 Strander Bl John W. Rants, Mayor This letter is to inform you of corrections that must be addressed before your application for development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed review comments from the Building Division. At this time the Fire Department, Planning Division and Public Works Department have no comments regarding your application for permit. The City requires that two (2) complete sets of revised plans be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a Revision Sheet must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions please contact me at the City of Tukwila Permit Center at (206) 431 -3672. Sincerely, 1/(ze » 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • (206) 4313670 • Fax (206) 4313665 BUILDING DIVISION PLAN REVIEW COMMENTS PAGE 1 OF 2 DATE: PROJECT NAME: PLAN CHECK NO: Plan Reviewer: `.aaid:: aft:.`:VO9: 4174 , 4 1 : RZ -t'e ■ .:'rrw?i: a:^;tk ` t October 27, 1997 Condon - Johnson, Inc. D97 -0337 Bob Benedicto - (206) 431 -3676 i n x i,r�c 4'�'M �F ,S p�ti4" •f '. �' Lr'. .�Yy!..'r• 'S1�. j�1 {: �w- +.' Y �3 :.. Additional information for documentation on the plans will be required as follows: v1The redeveloped corridor shall be not less than 44- inches in width. UBC 1005.2 Dimension the proposed width of the new corridor on the plan. ..45" eaj Cezudot wera ent VI The proposed reconfigured corridor exit system is required to be not less than one hour fire resistive construction. The details of wall sections submitted with this application note "existing roof structure" as the termination of the corridor wall construction. The main floor plan shows stairways to an upper floor level therefore indicating that the actual termination of the corridor walls will be the under side of th floor above. Provide a new detail showing the required one hour fire resistive ceilin assembly proposed for this construction. Detail or otherwise note to the plans that all doors leading to the fire resistive corridor shall be 20 minute fire resistive door /frame assemblies with self closers, smoke and draft control gaskets and labeled by the listing agency. Note: this applies to all doors providing access to the corridor whether new or existing. 0 ."1-ci y..4 02441 1 . • • v4. The suite located in the Southeast corner of the main floor may require two exits depending on the proposed use of the rooms that are to be developed. Although two exits are shown for this plan they do not provide the separation required when two exits are required. Please label each room in this suite so that the occupant load can be established. Note: if two exits are not required, due to the occupant load, then no change to the door location is required. i2.00+wa gatmtge Cete c t a� �,u a, k 1.."60 cut .e.iZt .. ode, a2:144huj., dwo pc.c•T .as •( .w 0 part v-5 stairs at the lobby area and at the South end of the main floor plan will now share common atmospheres with a one hour fire rated corridor. If these stairways are not separated from the upper floor uses or do not lead to a one hour fire resistive corridor on the upper floor, they will have to be so separated as a condition of approval of this tenant improvement. Please clarify the condition of the stairway access to the upper floor. Ca►uct a+l rt g /a leeet Go.rcdot .. z'4`c ` Gor u•`►� � d � -c t Cn,.,,, 4 00,1144, .. • : . D.kk aGt r .. . 6. New lighting proposed for the main floor plan must be shown on the plan in addition to a lighting schedule showing the fixture type, manufacturer, number of lamps and watts per fixture. Controls for said lighting (if new) must also be shown on the plans. ' , _ SEC. to (aoo7 Re: City of Tukwila Fire Department Review . Control # 01- _033 John W. Rants, Mayor Fire Department Thomas P. Keefe, Fire Chief T . I . at G.3 I &tr.*, ci QL G Dear Sir: The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. The total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 3000 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 10B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (NFPA 10, 3 -1.1) Extinguishers shall be installed on the hangers or in the brackets supplied, mounted in cabinets, or set on shelves (NFPA 10, 1 -6.9), and shall be installed so that the top of the extinguisher is not more than 5 feet above the floor. (NFPA 10, 1 -6.9) Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be identified with a sign stating, "Fire Extinguisher ", with an arrow pointing to the unit. (NFPA 10, 11 -6.3) (UFC Standard 10 -1) Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5) Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. (NFPA 10, 4 -3, 4 -4 and 4 -4.3) Every six years, dry chemical and Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 5754439 City of Tukwila John W. Rants, Mayor Fire Department Thomas P. Keefe, Fire Chief Page number halon type fire extinguishers shall be emptied and subjected to the applicable recharge procedures. (NFPA 10, 4 -4.1) If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10A -4 -4) Maintain fire extinguisher coverage throughout. 2. No point in an unsprinklered building may be more than 150 feet from an exit, measured along the path of travel. (UBC 1003.4) No point in a sprinklered building may be more than 200 feet from an exit, measured along the path of travel. (UBC 1003.4) Exit doors shall swing in the direction of exit travel when serving any hazardous area or when serving an occupant load of 50 or more. (UBC 1004.2) 3. Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 1207.3) Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. 4. When two or more exits from a story are required, exit signs shall be installed at the required exits and where otherwise necessary to clearly indicate the direction of egress. (UBC 1013.1) When two or more exits from a story are required and when two or more exits from a room or an area are Headquarters Station; 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 575-4439 City of Tukwila Fire Department Thomas P. Keefe, Fin' Chief Page number 3 required by U.B.C. Section 3303, exit signs shall be illuminated. (UBC 1013.3) Internally illuminated exit signs shall have both bulbs working at all times. (UBC 1013.3) 5. Exits shall be illuminated any time the building is occupied with light having an intensity of not less than 1 foot candle at floor level. Fixtures required for exit illumination shall be supplied from separate sources of power for Group I, Divisions 1.1 and 1.2 occupancies and for all other occupancies where the exiting system serves an occupant load of 100 or more. (UBC 1012.1, 1012.2) The power supply for the exit pathway illumination shall normally be provided by the premise's wiring system. In the event of its failure, illumination shall be automatically provided from an emergency system. Emergency system shall be supplied from storage batteries or an on -site generator set and the system shall be installed in accordance with the requirements of the Electrical Code. (UBC 1012.2) 6. Maintain sprinkler coverage per N.F.P.A. 13. Addition /relocation of walls, closets or partitions may require relocating and /or adding sprinkler heads. Sprinkler protection shall be extended to all areas where required, including all enclosed areas, below obstructions and under overhangs greater than four feet wide. (NFPA 13 -4- 4.1.3.2.1) 7. Maintain hose station coverage per City Ordinance #1742 and N.F.P.A. 14. Addition /relocation of walls or partitions may require relocating and /or adding hose stations. 8. An approved hose station requires plans review. (Plans must be submitted to the Fire Marshal for approval prior to installation.) (City Ordinance #1742) John W. Rants, Mayor Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206) 575-44.39 City of Tukwila Page number 4 9. All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recognized by The City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1742) All sprinkler system plans, calculations and the contractors Materials and Test Certificates submitted to The Tukwila Fire Prevention Bureau must be stamped with the appropriate level of competency seal. (WAC 212 -80) 10. Maintain automatic fire detector coverage per N.F.P.A. 72. Addition /relocation of walls, closets or partitions may require relocating and /or adding automatic fire detectors. Maintain square foot coverage of detectors per manufacturer's specifications in all areas including: closets, elevator shafts, top of stairwells, etc. (NFPA 72, 5- 1.3.4) 11. All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1742) (UFC 1001.3) 12. All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 13. Required .fire resistive construction, including occupancy separations, area separation walls, exterior walls due to location on property, fire resistive John W. Rants, Mayor Fire Department • Thomas P. Keefe, Fire Chief Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 575.4439 ' Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575 4404 • Fax (206) 575-44.39 • Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone; (206) 575.4404 • Fax (206) 575.4439 1 • ' C PLAN REVIEW / ROUTING SLIP ACTIVITY NUMBER 0q1-0337 DATE ], & PROJECT NAME Go fldCV) CEhn,on • P@ i i s,r.'t. DEPARTMENT: BUILDING DIVISION tif FIRE NTION PLANNIN4D SION 0 PUBLIC WORKS sTRuc PERMIT COASINATOR NR DETERMINATION OF COMPLETENESS: (T,Th) DUE DATE N1)L COMPLETE El COMMENTS TUES /THURS ROUTING: PLEASE ROUTE ( NO FURTHER REVIEW REQUIRED ROUTED BY STAFF E] (If routed by staff, make copy to master file & enter Sierra.) REVIEWERS INITIAL APPROVALS OR CORRECTIONS: (ten days) APPROVED El APPROVED W/ CONDITIONS [] NOT APPROVED (attach comments) Q REVIEWERS INITIAL l CORRECTION DETERMINATION: APPROVED El APPROVED W/ CONDITIONS p NOT APPROVED (attach comments) 0 REVIEWERS INITIAL C:ROUTE -F NOT COMPLETE E NOT APPLICABLE El DATE DATE DATE I DUE DATE /1 9 7 DUE DATE (Cemfica ioa of occupancy required, �.1 REVIEWERS INITIAL APPROVED El REVIEWERS INITIAL REVIEWERS INITIAL C:ROUTE -F DEPARTMENT: BUILDING DIVISION 111 FIRE PREVENTION El PLANNING DIVISION El PUBLIC WORKS STRUCTURAL El PERMIT COORDINATOR 0 4 { , {� PLAN REVIEW / ROUTING SLIP ACTIVITY NUMBER f q f _O 337 DATE I,11 PROJECT NAME CO �• CEhn iofl - (?u, 5�)�t. DETERMINATION OF COMPLETENESS: (T,Th) COMPLETE C] NOT COMPLETE NOT APPLICABLE Q COMMENTS TUES /THURS ROUTING: PLEASE ROUTE d NO FURTHER REVIEW REQUIRED El ROUTED BY STAFF El (If routed by staff, make copy to master file & enter Sierra.) APPROVALS OR CORRECTIONS: (ten days) APPROVED W/ CONDITIONS ,(46 CORRECTION DETERMINATION: APPROVED C] APPROVED W/ CONDITIONS DATE DATE 1t -1 7 -9 ` DATE I I.-11-9 DUE DATE DUE DATE I l e 0 NOT APPROVED (attach comments) El 1 DUE DATE NOT APPROVED (attach comments) 0 (Certification of occupancy requited. ACTIVITY NUMBER PROJECT NAME DEPARTMENT: � ING DI VIISIO N ❑ DETERMINATION OF COMPLETENESS: (T,Th) COMPLETE C21 COMMENTS TUES /THURS ROUTING: PLEASE ROUTE C ROUTED BY STAFF n (If routed by staff, make copy to master file & enter Sierra.) REVIEWERS INITIAL DATE APPROVALS OR CORRECTIONS: (ten days) DUE DATE /O7, 7 elb APPROVED ❑ APPROVED W/ cONDITIONS ❑ NOT APPROVED (attach comments) Corjj1Q+e r d� Kap IAI. DATE CORRECTION DETERMINATION: APPROVED l ! REVIEWERS INITIAL C:ROUTE -F Petwu+ Coord Copy PLAN REVIEW / ROUTING SLIP U91 - 0337 0 1o:LeY_97 Co ri don Xne Q-0 FO PREVENTION Vt STRUC TURAL (V NOT COMPLETE ❑ • APPROVED W/ CONDITIONS ❑ DATE to P ING,,DIVI�SIION ❑ PERMIT COORDINATOR 4 DUEDATE /o' «-97 NOT APPLICABLE ❑ NO FURTHER REVIEW REQUIRED ❑ DUEDATE NOT APPROVED (attach comments) ❑ (Cerdficadon of occupancy required. ACTIVITY NUMBER oqi- 0331 DATE 10-ILI•97 PROJECT NAME Condon • ir5ot) Zne DEPARTMENT: BUILDING DIVISION 11 FIRE PREVENTION E PLANNING DIVISION PUBLIC WORKS STRUCTURAL El PERMIT COORDINATOR El DUEDATE 1a - «•q7 • . • COMPLETE F NOT COMPLETE Ej NOT APPLICABLE COMMENTS ra`cl ct wr 5 Vt o w LLer / DETERMINATION OF COMPLETENESS: (T,Th) TUES /THURS ROUTING: PLEASE ROUTE ROUTED BY STAFF n (If routed by staff, make copy to master file & enter Sierra.) REVIEWERS INITIAL �.. DATE t (it /*"."? APPROVALS OR CORRECTIONS: (ten days) APPROVED El APPROVED W/ CONDITIONS C NOT APPROVED (attach comments) Er REVIEWERS INITIAL C:ROUTE -F PLAN REVIEW / ROUTING SLIP CORRECTION DETERMINATION: DATE NO FURTHER REVIEW REQUIRED El DUE DATE I0 . 4 7 10-27 -97 DUE DATE APPROVED n APPROVED W/ CONDITIONS p NOT APPROVED (attach comments) 0 REVIEWERS INITIAL DATE (Certification of occupancy required. .5 �: }F•^y, ^(.:N t' ;F; + ' ��v;�.: IY to I ti 'IiiNJS °. 7•I.,Y V/ M f }' 1' A`, . i •.v � r `) S,��yy l,'R C � S 4J� �.��,. 1✓ �;. �,'' 9Jt1 .�it.SF::5�. +1'`!t:M'��Ld:45. 731�Y1A�� � �7' }Y '�.�� "Yn �ih `„v`���+T��"'�.'t'4�m"A7. -4 .?S µY�T�?w'�f, e n J.:.. i /r Wit• c.x +. t �. .F! 7 PLAN REVIEW / ROUTING SLIP ACTIVITY NUMBER D o 331 D ATE �o1y Z q 7 Cor,dori - Son PROJECT NAME DEPARTMENT: BUILDING DIVISION E FIRE PREVENTION 111 PLANNING DIVISION PUBLIC WORKS STRUCTURAL E PERMIT COORDINATOR Q l DETERMINATION OF COMPLETENESS: (T,Th) • COMPLETE n COMMENTS • TUES /THURS ROUTING: PLEASE ROUTE (J NO FURTHER REVIEW REQUIRED • ROUTED BY STAFF n (If routed by staff, make copy to master file & enter Sierra.) REVIEWERS INITIAL APPROVALS OR CORRECTIONS: (ten days) DUE DATE /0 -1-7 APPROVED n APPROVED W/ CONDITIO REVIEWERS INITIAL 510 CORRECTION DETERMINATION: APPROVED Ell APPROVED W/ CONDITIONS REVIEWERS INITIAL DATE C:ROUTE - F DATE • NOT COMPLETE • NOT APPLICABLE DATE (O Z.c fl DUE DATE 1 (64.97 NOT APPROVED (attach comments) El DUE DATE NOT APPROVED (attach comments) (Certification of occupancy required. ) 'S'.N'rr V '�N 43• •Y+ xP , QTY' Magitn `'�i tt'.i . ".' �` :! �A�, �Se�I ��N��. e. �iSaiKTYiiitfs `WV�,���3#}t�td4/":'C�S +i'v��•." r�.�:"d��?�'')��f e:�tirj '.•t?� REVIEWERS INITIAL C PLAN REVIEW / ROUTING SLIP ACTIVITY NUMBER o q � ' o 3?/ DATE 104 PROJECT NAME DEPARTMENT: BUILDING DMSION ❑ FIRE PREVENTION ❑ PLANNING DIVISION ' PUBLIC WORKS LJ STRUCTURAL ❑ PERMIT COORDINATOR ❑ 4 DETERMINATION OF COMPLETENESS: (T,Th) COMPLETE n NOT COMPLETE ❑ COMMENTS TUES /THURS ROUTING: PLEASE ROUTE ❑ NO FURTHER REVIEW REQUIRED 1 ROUTED BY STAFF El (If routed by staff, make copy to master file & enter Sierra.) REVIEWERS INITIAL DATE I 19 I/ (PI'7 7 1 APPROVALS OR CORRECTIONS: (ten days) DUE DATE /0 APPROVED n APPROVED W/ CONDITIONS ❑. NOT APPROVED (attach comments) E. CORRECTION DETERMINATION: APPROVED Fl APPROVED W/ CONDITIONS ❑ NOT APPROVED (attach comments) 0 REVIEWERS INITIAL DATE C:ROUTE -F a DATE DUE DATE /d " NOT APPLICABLE [z DUE DATE (Cerdficadoa of occupancy required. ) -. r t h'�'h'k; N �hyr .�� Y °'y',Yr :A. hriFCiYti,,. .. "'•,J� ,'i'.�" �l��Y��iir"'d' #.q �is� {,�t+�mmt���'.t':�:,���ti�,}�� m r1 „•u��„�r, ' ACTIVITY NUMBER PROJECT NAME DEPARTMENT: BUILDING DIVISION ❑l PUBLIC WORKS • s DETERMINATION OF COMPLETENESS: (T,Th) NOT COMPLETE ❑ • COMPLETE COMMENTS • TUES /THURS ROUTING: PLEASE ROUTE fl ROUTED BY STAFF ri (If routed by staff, make copy to master file & enter Sierra.) REVIEWERS INITIAL APPROVALS OR CORRECTIONS: (ten days) APPROVED ❑ APPROVED W/ CONDITIONS ❑. DUE DATE IO • -97 REVIEWERS INITIAL CORRECTION DETERMINATION: APPROVED C:ROUTE -F 091 -0337 • FIRE PREVENTION ❑ STRUCTURAL ❑ APPROVED W/ CONDITIONS DATE DATE REVIEWERS INITIAL DATE • PLAN REVIEW / ROUTING SLIP DATE 'O 1 97 PLANNING DIVISION a PERMIT COORDINATOR ❑ DUE DATE 10 16 97 NOT APPLICABLE g NO FURTHER REVIEW REQUIRED ❑ NOT APPROVED (attach comments) ❑ DUE DATE NOT APPROVED (attach comments) ❑ (Certification of occupancy required. ) 4v��i1.S'34Str%:KrnaiV :'�7' O+1711A,V titi' t'tN?M" AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION STATE OF WASHINGTON ) COUNTY OF KING a. f /7/ Gt /4EL 5 4/ , states as follows: 1. I have made application for a building permit from the City of Tukwila, Washington. 2. I understand that state law requires that all building construction contractors be registered with the State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the Revised Code Washington, a copy of which is printed on the reverse side of this Affidavit. I have read or am familiar with RCW 18.27.090. 3. I understand that prior to issuance of a building permit for work which is to be done by any contractor, the City of Tukwila must verify either that the contractor is registered by the State of Washington, or that one of the exemptions stated under RCW 18.27.090 applies. 4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby attest that after reading the exemptions from the registration requirement of RCW 18,27.090, I consider the work authorized under this building permit to be exempt under No. /3 , and will therefore not be performed by a registered contractor. I understand that I may be waiving certain rights that I might otherwise have under state law in any decision to engage an unregistered contractor to perform construction work. ,,op llr uist • n it ,: • (1) 'CI o, r .'s,, OF WAS 48 •111141110‘ - AFFCONT,DOC 5/29/96 • CITY OF T( YWILA Permit Center 6300 Southcenter Boulevard, Suite 100, Tukwila, WA 98188 Telephone: (206) 431 -3670 r V ss. Signed and sworn to before me this /9'4 day of lirea NOTARY PUBLIC in and for the State of Washington, residing at -d EIS.\ l � ) IACL County. Name as commissioned: 1\1( \r-a. oel'(.S My commission expires: I /( _/ 18.27.090 Exemptions. This chapter shall not apply to: 1. An authorized representative of the'united States Government, the State of Washington, or any incorporated city, town, county, township, irrigation district, reclamation district, or other municipal or political corporation or subdivision of this state; 2. Officers of a court when they are acting within the scope of their office; 3. Public utilities operating under the regulations of the utilities and transportation commission in construction, maintenance, or development work incidental to their own business; 4. Any construction, repair, or operation incidental to the discovering or producing of petroleum or gas, or the drilling, testing, abandoning, or other operation of any petroleum or gas well or any surface or underground mine or mineral deposit when performed by an owner or lessee; 5. The sale or installation of any finished products, materials, or articles of merchandise which are not actually fabricated into and do not become a permanent fixed part of a structure; 6. Any construction, alteration, improvement, or repair of personal property, except this chapter shall apply to all mobile /manufactured housing. A mobile /manufactured home may be installed, set up, or repaired by the registered or legal owner, by a contractor licensed under this chapter, or by a mobile /manufactured home retail dealer or manufacturer licensed under chapter 46.70 RCW; 7. Any construction, alteration, improvement, or repair carried on within the limits and boundaries of any site or reservation under the legal jurisdiction of the federal government; 8. Any person who only furnished materials, supplies, or equipment without fabricating them into, or consuming them in the performance of, the work of the contractor; 9. Any work or operation on one undertaking or project by one or more contracts, the aggregate contract price of which for labor and materials and all other items is less than $500, such work, or operations being considered as of a casual, minor, or inconsequential nature. The exemption prescribed in this subsection does not apply in any instance wherein the work or construction is only a part of a larger or major operation, whether undertaken by the same or a different contractor, or in which a division AFFCONT.DOC 5/29/96 of the operaardn is made into contracts of amounts less than $500 for the purpose of evasion of this chapter or otherwise. The exemption prescribed in this subsection does not apply to a person who advertises or puts out any sign or card or other device which might indicate to the public that he is a contractor, or that he is qualified to engage in the business of contractor; 10. Any construction or operation incidental to the construction and repair of irrigation and drainage ditches of regularly constituted irrigation districts or reclamation districts; or to farming, dairying, agriculture, viticulture, horticulture, or stock or poultry raising; or to clearing or other work upon land in rural districts for fire prevention purposes; except when any of the above work is performed by a registered contractor; 11. An owner who contracts for a project with a registered contractor; 12. Any person working on his own property, whether occupied by him or not, and any person working on his residence, whether owned by him or not but this exemption shall not apply to any person otherwise covered by this chapter who constructs an improvement on his own property with the intention and for the purpose of selling the improved property; 13. Owners of commercial properties who use their own employees to do maintenance, repair, and alteration work in or upon their own properties; 14. A licensed architect or civil or professional engineer acting solely in his professional capacity, an electrician licensed under the laws of the state of Washington, or a plumber licensed under the laws of the state of Washington while operating within the boundaries of such political subdivision. The exemption provided in this subsection is applicable only when the licensee is operating within the scope of his license; 15. Any person who engages in the activities herein regulated as an employee of a registered contractor with wages as his sole compensation; 16. Contractors on highway projects who have been prequalified as required by chapter 13 of the Laws of 1961, RCW 47.28.070 with the department of transportation to perform highway construction, reconstruction, or maintenance work. cr _• ■ 1':::1 ,..... _.3 andlomissiores pl ..::::::3 not :a__,.._d code ce ,. t ort 1 ! c:or's 1 Plan Ciic 1 a.. 1 ' I* violation -. alifiett of copy cf approved 1110110511. or I Permit Nol — MAIN r-LOOF PLA N Dq7 -037 RECEIVED CITY OF TUKWILA DEC 021997 PERMIT CENTER dPENi 6F (v ) LPEN tFf"cE — - - _ . -Q-11/411° &. L() _ _ _ _ e= = WALLS ° N - B� . P O\IED rtEW 61J - ST�U Ll ut2AL— TE • L4JAL1_ mnrizLi2 = ADD b PrL tijALI,S OR161>JAL L. TO.NANT I AT• 6: THE FIRE I FOR A M U t r L, Y1 �i1V C0 L ^v`'2 C:W LETr AND cc; i BUILDING G - - Bu ILDiNG D BUILDING E BU!LDING F 4/C b vi J 1 1V11,...lan OL V U. 601 -625 STRANGER BLVD. • 633 -649 STRANGER BLVD. 659 -677 STRANGER BLVD_ 770". !4f .o i; >ilc -.r .fsr1e,, r.i.ry k .- .,, c,F Via;- rr < ..r K <?•t...ar.. ,.i.. -. �,. .. -.aw. t .�:- .. -. i_F; 111 4001 111117111111 t _ _ • E rill nn, 'ITTITTIIIIMY MI! t6 • • 9 KOLL COMMERCE [ENTER TACT II ANDOVER RECEIVED CITY OF TUKWILA C PERMIT CENTER DirTh033? f ECEivEb CI M ' OF TUKWQ,4 PER?,A1T , O , NTER SITUATED ,1 1 TN E'.NORTHWEST QUARTER OF•.SECTLOJJ . 25, ;TOW"NSHIP ,23 NORT RANGE 4 EAST, WILLAMETTE ��; MERIDIAN 'CITY OF`, TUKWILA, ;.KING COUNTY, WASHING fbH,, AND BEING Via_ PORTION . TRACT: 2 PLAT OF ANDOVER INDUSTRIAL PARK NO 4 ,A$ RECOROEb;IN PLAT'iBOOK70 PAGES 39 PLAT RECORDS SAID COUNTY, ND :BEING DESO.ri1BE0 AS•1' "'S 1 - BEGINNING .AT THE NORTHWEST COIN OF SAID ,TRACT 2; AND A POINT ON TIIE SOUiH.�lGtfit - O WAY,.LiNR OP : STRANGER BEING _30,60. FEET FROM THE CENTERLINE WHEN MEASURED A`' FIGHT ANGLES, SAID POINT BEING SOUTH 88'15'33" EAST; A bI 'fANCE OF 45.21;F( ET ANR SOUTµ,O1`44'2 " . WEST, A D,CTANCE OF 30.00 FEET ,, FROM;, THE_ NORTHWEST'G OF' GO VERNMENT; LOT 4 SAID SECTION AND RUNNI0?1 8 00TH,89'j5 00`;EAST, NORTH LINE'OF SAID TRACT 2 =, ANb ;S/AICS. SOUTH RIGHT, (7F -WAY. LINE A DISTANCF OF79.62 FELT.TO A POINT ON A N0H TANGENT 16.07t1gr RADIOS CURVE LEFT. LINE, RADIUS POINT BEARS NORTH 61'37'4: ;EASTI; = THENCE LEAVING SAIL) NORTH TRACT LINE AND SAID SOUTH RIGHT - •,OF- WAY'LINE' JLUNNINQ QN''SAID -, CURVE: THROUGH •A CENTRAL ANGLE OF 79'07.38'.; (THE,LONG CHORO.OF. WHICH.BEARS SOUTH EAST, A DISTANCE OF 147 86 FEETI;AN ARC. DISTANCE OF',180.30.FEET END THEREOF AND THE BEGINNING OF A' TANGENT46.Oo SOOT RADIUS.CURVE LEFT; THENCE ON SAID CURVE THROUGH A CENTRAL ANGLE 4z 52-08',(THE LUNG. CHORD OF WHICH BEARS NORTH `51'04 OC ;AST •'A.' DISTANCE OF 55.55 FEETI ;AN ARC DISTANCE OF 56,80 FEET TO THE.END THEREOF �AND ,THt BEGINNING OF A' TANGENT' 26.95 FOOT RADIUS CURVE ;.';RIGHT,THENCE; SAID CURVE THROUGH A CENTRAL ANGLE, OF 62. ITHE LONG CHORD O REARS NORTH 60'48'11' EAST, A DISTANCE OF 27.90 FEET) AN ARC DISTANCE O F •29.32 FEET TO THB'END T HER °OFD THENCE CONTINUING AROUND SAID ` TRACT.24.E FOLLOWING COURSES ;` SOUTH 88 01'35' EAST, A DISTANCE OF 127.58 FEET; 'THENCE SOUTH 51.'48'35 EAST, A DISTANCE OF 299.27 FEET) THENCE SOUTH 32 55'34!'; ;EAST,' A :DISTANCE OF 154.57 ,FEET; THENCE SOUTH 0220'25' WEST, A DISTANCE; OF'.123.87 FCET;.':THENCE ,SOU fH0 02 °25' WEST; A DISTANCE OF 252.73 FEET TO`THE MOST SOUTHERLY. CORNER OF SAID, TRACT 2, THENCE ON THE COMMON LINE, BETWEEN'. TRACT 1. AND' TRACT•7,SAID PLAT: THE. FOLLOWING COURSES: NORTH 61 `,41 08 WEST; 'A DISTANCE '05: FEET ;'.THENCE NORTH 42'36'45 ". WEST, A D(STANCEi{3F 755;44 FEET ,THENCE.NORTH'O1'44',27 ",' EAST, A. DISTANCE OF 51.32 FEET TO THE POINT OE,BEGINNIN(3`.CONTAININO 5:525 ACRES MORE OR LESS. • y . r BASIS OF,, BEARING FOR ;THIS LEGAL DESCRIPTION IS THE RECORDED PLAT OF ANLOVFR INDUSTRIAL PARK NO, 4. 651 STRAiNGEF' BLVD. • 679.690 STRANGER BLVD. 801 -625 STRANGER BLVD. 633.849 STRANGER BL = 659.677 STRANGER BLVD. I-; EX151W ROOF STRUCTURE ABovE NEW SLIP JOINT NEW 31/2" METAL STUDS 24' OG. SOUND BAIT INSULATION 578" TYPE X GWB I- HOUR F12E - RATE D I /4' RAWL PINS 32" 0.C. VINYL COVE BASE EXISTING CIARPET' 7 -- LXISTIN6 CONCRETE FLOOiZ. C) WALL SECTION DETAIL A -I I N EXISTING ROOF STRUCTURE ABOVE NEW 1 - HOUR LbR>=ISDAR D ii55E1 EXISTING 61,1b/FRAMING CEILING ASSEMBLY NEW 3 1 12" METAL 571JD5 2A "D,C. SoLivD BATT INSULATION .5/8" TYPE X GWE RAWL PINS 32' D.C. vinlYL GIVE BASE EXISTING CARPET FASTING CONCRETE ELGoR WALL SE CTION DETAIL SL ALE I /4" I (3" j)97 EXISTING ROOF STRUCTURE A2LA/E NEW SLIP JOINT AltW 3 1 /2" METAL STUDS 24" O.C. w /578 OWE ROTH 5W Es ABOVE EXISTING WALL ASSEMBLY ` - tJ(i TtNG SUSFEAII)ED CEILING EXISTING 3 ' /2' 24-" O.G. 5 /0 TYPE X &J6 / VINYL COVE RASE EXISTING CARET 1// CONCRETE FLOOf; WALL 3EcTION DETAIL YALE 1, Po" P/L IF IL GULF BD5INIE55 PAR k_ APPROVED BY: WALL SECTION .DETAIL_ RECEIVED CITY OF TUKWILA PERMIT CENTER I DRAWING NV4IBER I £ °7-O 3 7 DRAWN BY REVISED 4 De') Ti AL EXISTING FIRE L J/ LLS 5U1 110 II I I I II it ii n I I' ! I I I I I I I I I I I I I I I I I I I I I I I I I I PART IF%i_L T' EXISFIN6 ,''IRE WNLLS I I l l I pq7 -o 33' I I Brgce c zl(- {aR - .0 .. I I old' DEEP /5" H /Gff 1 1 —: 11_ SHELVES _ _1- -= - - 11 - it / c) R) /; /AL E xTS G11 \ NOTES Sc-RZW M1 SND f1�f�UL — li iz - tz') C.k.G CAW D 3g13 &A, S m A\D5 ZZa[� �� Q C U// 5� °' TIP "X' (YPL(.,A EA. SIDE 4" v ItJ YL LOVE NEr/ LEA/ pcloP CA PE. /I c_- to A ta,i5, 3/gip/M._ sm.i D 2 Q A GE O.c.. (T(P ) E X TG CboorZ 5 lihrhillthittillitikli Ltd VI I'M V111111411011 i 11 till E ACCL 511W3L GL(. 1?)vILDItIC7 ricyr rifts SP42JNKLERLD OCGU°PANICJ( GROUP F3 LOti1SkzuCA1 On.) TYPE S --N 4), All Neva Co/J6fRucirorJ To GOMPLf Wlicoq UE3L Aldo ITb Ravl.SIWJ.S Jr) Ex15T1NG LIGNTl1JG # ELeCTPIcriL TV REM/11,/- 6.) U_50'L1.IDgt CE NG TU QEMA/kJ, 0 41 NO1E5 L HAL.u1AY TO 13E AT LEAST' q 2. iNCtWES CLEAR_ PER WA. STATE E.C. F,, n►bMEWT CNkPTts H SELT►oN 11 a6. la. 2- NEW OFFICE 4 14ALLwAY ELtc.TIZ CAL._ Ll6147inlf 1.2 tAihrrS PER. ,Sa F'_ FGA ® FIIp c AN D 2 vJff PEe Foe_ Cop/4A as A; a s PEP-- u E . - r$ 3 LE 15 -1 cfficE OfFt�.;E O ff a cDocr BAR 111111111011111111■1Y11 %ISM, ■1■11_ \ II iMMI11,1111 Cok 1rT�c 1 I 11 Sc.)ITGH � • I C: 4 ;� T I Nru1 2x 3- &E FL0:. teC6Nr Fixr'r.r tAilrH Phi BOLIc Gt:/iJ.. 3. BUILDING 1.1 61" F IRE 3Yk)t >`L£Kru. 1\14h 14r?1!1i, - E_O 1'14 ft f Itr3frll,E Oc_cuPM41Y GROUP Co JST KUL.TI DN TY 4'E 5 -N 5. ALL NEW CDN.YFRUCT1UN TG CGMPLY IGg4 LIBC AND ►TS RE,(IS',NS _ Ex15TING GRID C.EIL IN& TO REMAIN — NO NEW CEILING kt)DeID, 5P 110 `-715 rE9 MAIN LOo E\ PLA N V6 °ARMOR 48 INCHES ODE -- I r 1 1 it 1 1 II II °1 II I I 11 1 IL Ir 1 II 11 I I I I 1 I I I I I I 11 - EMSTIr1G WALLS I I I II I I I I _ _ _ _ _ = z WALLS TU Be REN:vED SUZCSZ=S= 2! NEW In► A LL S TO B E UK) STA'. U CI"f FEU15 /0ov /// / 7 I I EI oGFtGg NOTE RECEIVED Orr' OF TUKWILA N O V n ,; 1997 01411Tr MINIUM A1_ DbcR5 LEAD Tc) THE Fi E RE5 CoRR►D6>z BE 2v M ;Al. rhf : ?CS/SrIvE "ALL', / riCAegg ASSLMBLIES wiTN SELF CLVSE�S, 5;1_ DRRFT LGNTR'OL LJtEkz_ SY 7'ttE L1 it/ />GL PEFI , .X1 FCQ IRED F,_ _ r;ct authorize the Vic, —._ . Lf aPtsPmved Pens code or of cc -. II METE DRI61UAL CoKk'UOL wAS tkv IL T NRNr IMPFZDULIIaNT, LEAVING A b RCJzS_ AT THE GRIDCEIL■nIG I te EKT T_L_ TIHE FIRE RATED LDRRILWR [.DILL ?s RE- Iusr+ �c FGR A MULTI TeNAtJT USE_ AS 61216 /kALLY PLAntNEO AND ApV1?DUEO_ THE C u1ti 1-0 I—a® ' L);/51")/46 FIRE WALLS" tulLL Bt r LETS D 61COM THE L'' 1ZtVEAL AND CoL3F Tip nv C L) A5 FinE WAC� S DAIS S l ST>,1�Ct ►? bLv b - 40"7-0" I 1 1 A If,