Loading...
HomeMy WebLinkAboutPermit D2000-188 - TANDY - WALLTANDY D2000-188 City of Tukwila Permit Center Authorized Signature :�J(1..( Date development permit. Signature: (206) 431 -3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 DEVELOPMENT PERMIT WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL. PERIOD EXPIRES, APPLICANT IS PROCEEDING AT THEIR OWN RISK. Parcel No: 022340 -0070 Permit No: D2000 -188 Address: 541 INDUSTRY DR Status: ISSUED Suite No: Issued: 06/26/2000 Location: Expires: 12/23/2000 Category: AOFF Type: DEVPERM Zoning: Const Type: V -N Occupancy: OFFICE Gas /Elec.: UBC: 1997 Units: 001 Fire Protection: AUTO FIRE ALARM Setbacks: North: .0 South: .0 East: .0 West: .0 Water: N/A Sewer: N/A Wetlands: Slopes: N Streams: Contractor License No: DVGCOI*O11PL OCCUPANT TANDY. Phone: 541 INDUSTRY DR, TUKWILA, WA 98188 OWNER EQUITEC R E INVESTORS FUND 16/ A/P UTILITIE'S, 617 INDUSTRY DR, TUKWILA WA 98188 CONTACT DAN GARVIDA Phone: 425- 830 -5496 12038 SE 169 PL, RENTON, WA 98058 CONTRACTOR D V -G CONSTRUCTION INC 12038 SE 169TH PL, RENTON WA 98058 tk• k'****** k**** k• k**** *:k *k**** ***** * **** ** ***** **k•k•k•k•k•k*** **k *•k•k*•k• *** *** *:k *•k*** * **k* Permit Description:' TENANT IMPROVEMENT .= MINOR WALL ADDITION. k*******************• k******• k*** ***k*kk** ***•k ** * * * ** * *k * *k* * ** ***fir * ******k** * *•k* *•k *•kk Construction Valuation: $ 2,000.00 PUBLIC WORKS PERMITS *(Water Meter Permits Listed Separate) Eng. Appr: Curb Cut /Access /Sidewalk /CSS: N Fire Loop Hydrant: N No Size(in): .00 Flood Control Zone: N Hauling: N Start Time: End Time: Land Altering: N Cut: Fill: Landscape Irrigation: N Moving Oversized Load: N Start Time: End Time: Sanitary Side Sewer: N No: Sewer Main Extension: N Private: N Storm Drainage: N Street Use: N Water Main Extension: N Private: N ********* ** ** ** * **k***** *** * * * * ** *kk **** SIC*: k********k* **k** ** * * **k* ** ***** ** *** * * **** TOTAL DEVELOPMENT PERMIT FEES: t 118.76 *******' k***************** * ** * * * ** * * **** * * **`k* • ***. • ** * *:kw * *****ic *** * *k*** ***•k* * *** Public: N Public: N I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this Date : J � - Print Name: I This permit shall become null and void if the work is not commenced within 130 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. 2 cd 41 V u) 0 N w w O u- -J = d ' w Z Z O F— ' 0— o H! w w ' O : 11J Z ` O Z CITY OF TUKWILA Address: 541 INDUSTRY DR Permit No: D2000-188 Suite: „ Tenant: Status: ISSUED Type: DEVPERM Applied: 06/13/2000 Parcel #: 022340-0070 , Issued: 06/26/2000 ********************************k*k*********Vk***k******** Permit Conditions: 1. No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 2. .A11Ormits, inspection records, and approved plans shall be avail'able at the job site prior to the start of any con- structlbn. ' These documents are to be maintained and avail- able until final inspection approval is granted. 3. Electrical permits shall be obtained through the Washington Stte Division of JLabor and Industries and all electrical work will'be inspected by that agency (248-6630). 4, Prumbi6g permits SWal1 be obtained through the Seattle-King County Department of Public Health. Plumbing will be inspected by that agency, including all gas piping , (296-4722). 5. All ,mechanical work shall be under separate permit issued by the City of Tukwila. . All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997, Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). T. Validity of Permit. The issuance of a permit or approval of ,plans, specifications, and computations shall not be con- strued to be a, permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. Project Name/Tenant: p Existing use: ❑ Retail ❑ Restaurant ❑ Multi- family .Warehouse ❑Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel 2rOffice ❑ School /College /University ❑ Other Value of Construction: Site Address: Cit State /Zip: 54 IPOU' VR.•, rt!Kw 1 Wf� cR1g Tax Parcel��mp 0221 - 1� Phone: IA( 579 5 . 1 Property Owner: k -t LV1�l , 9 Co tyi n1 �? c. f' t- Existing fire protection features: sprinklers Ja automatic fire alarm 173 none El other (specify) Street Address: ` , - I v i9v..,.rv , c Qv_ , l -o r r,a7 L j >, s,. CdtyIte/ ip: Fax #: zot, . 1 5. `ik Contractor: ry6 co T 2 ?C- \ pal 1p C... P hone: x{-75 7-35 • 7-1-51 Street Address: � �, 11/U915 - s i lr ��' C A=N it) i' State /Zi 4 yt p' Fax #: + 6 tiaI3 . y `, Architect: Phone: Street Address: City State /Zip: Fax #: Engineer: Phone: Street Address: City State /Zip: Fax #: Contact Person: DA 0 0. j?V 19ysc Phone: ,1 . 95 0 , - % 1 Lp Street Address: 1 ,, 1 , _ e. 1 (4 1-3 19L Fe a 1v N I ty Stake /t) Fax #: 4i4 71 5 2 Description ( work to be do e: P 4.- -t. 4.17 n II" (o Existing use: ❑ Retail ❑ Restaurant ❑ Multi- family .Warehouse ❑Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel 2rOffice ❑ School /College /University ❑ Other Proposed use: ❑ Retail ❑ Restaurant ❑ Multi- family .Warehouse In Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel ErOffice ❑ School /College /University ❑ Other Will there be a change of use? ❑ yes •❑ no If yes, extent of change: (Attach additional sheet if necessary) Will there be rack storage? ❑ yes 0 no Existing fire protection features: sprinklers Ja automatic fire alarm 173 none El other (specify) ;;..--s Building Square Feet: 1 74:00 existing 1 Area of Construction: (sq. ft.) Will there be storage of flammable /combustible hazardous material in the building? ❑ yes no Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets CITY OF TUKW A Permit Center 6300 Southcenter Blvd., Suite 100, Tukwila, WA 98188 (206) 431 -3670 ommercial / Multi - Family Tenant Improvement / Alteration Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. APPLICANT REQUEST. FOR PUBLIC WORKS SITE/CIVIL PLAN REVIEW OF THE FOLLOWING: (Additional reviews may be determined by the Public Works Department) ❑ Channelization /Striping ❑ Curb cut/Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: Size(s): ❑ Land Altering 0 Cut cubic yds. 0 Fill cubic yds. ❑ Sanitary Side Sewer #: El Sewer Main Extension ❑ Storm Drainage ❑ Street Use ❑ Water Main Extension El Water Meter /Exempt #: Size(s): 0 Deduct ❑ Water Meter /Permanent # Size(s): ❑ Water Meter Temp # Size(s): Est. quantity: ❑ Miscellaneous Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation, The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined In Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Da tgllcati In�epte� Date a Ilcalion x Tre !- I — U0 Ap ti aken by: (Initials) PLEASE SIGN BACK OF APPLICATION FORM CTPERMIT.DOC 1/29/97 �.. �3R"#1 +Y ,Ire!4JR'DY!1r1m!N^, amer ..LC"Y4 ^- its - a .us -... ...,m wslizia3.'L:" ❑ Flood Control Zone ❑ Hauling ❑ Landscape Irrigation O Private 0 Public O Private 0 Public 0 Water Only gal Schedule: ... . ... .M., r.rert+••?.•r.. raw•:,- n, wcrr+!• k!+ m;; r. s' 1fa' 4*. iHaPYlt. Y, 14k 'Ah!tNT3 Z ~ w 6 _J U 00 ❑ (" J U) u_ w a Z � ZI- w U • u) O - 0H ww 2 H LO W Z U = 0~ Z 'Ala awl __l gin Ilia � , ,1 BUILDING OWNER OR AUT /ZED AGENT: Signature:T ,� F--v %dam Date: v, .JU N i 5 O( Print name:"' N --/ V (G7 1 I Phone:0,6 •Ca J9C( Fax #: °1� 1 _1 Address `W2 } ,. c \ 6 C) v, (., l . City /State /Zip 12 . , , � 4-A 9 k w ALL COMMERCIAUMULTW MILY TENANT IMPROVEMENT -"" TERATION PERMIT APPLICATIONS 7RlIST BE SUBMITTED WITH THE • LLOWING: • ALL DRAWINGS TO BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT, STRUCTURAL ENGINEER OR CIVIL ENGINEER • ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN • BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A SUBMITTED ❑ ❑ Complete Legal Description ❑ ❑ Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures (Form H -13). Business Declaration required (Form H -10). Four (4) sets of working drawings (five(5) sets for structural work), which include : 1 t Plan (including existing fire hydrant location(s) North arrow and scale 2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements 3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions 4. Location of driveways, parking, loading & service areas 5. Recycle collection location and area calculations (change of use only) 6. Location and screening of outdoor storage (change of use only) 7. Limits of clearing /grading with existing and proposed topography at 2' intervals extending 5' beyond property's boundaries 8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of use only) 9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of Q those, identify by size and species which are to be removed and saved i z 10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change Ir 2 of use only) 0 11. Location and gross floor area of existing structure with dimensions and setback v p 12. Lowest finished floor elevation (if in flood control zone) co o 13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form H - co z 9) . u) u 1-- _ CI w Floor plan: show location of tenant space with proposed use of each room labeled 2 ❑ Overall building floor plan with adjacent tenant use;-identify tenant space use and location of storage of Q any hazardous materials; dimensions of proposed tenant space. cn a ❑ Vicinity Map showing location of site H = ❑ v ❑ � Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack z Z F- O layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of w w rack. Structural calculations are required for rack storage eight feet and over. o ri CI U u) Indicate proposed construction of tenant space or addition and walls being demolished p _ O I- CI Construction details W w ❑ Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of u- ~O water supply to sprinkler vault with documentation from contractor stating supply line will meet or Iii z exceed sprinkler system design criteria as identified by the Fire Department. v ❑ ❑ Washington State Non - Residential Energy Code Data shall be noted on the construction drawings. z 1-- ❑ ❑ SEPA Checklist - if intensification of use (check with Planning Department for thresholds). ❑ ❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other land use or SEPA decisions. ❑ El Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County Department of Public Health prior to submitting for building permit application. The Department of Public Health is located at 201 Smith Tower, Seattle, WA or call (206) 296 -4787. (Form H -5) ❑ ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no contractor has been selected at time of application a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. CTPERMIT.DOC 1/29/97 is ubcd?ei A 8.M 7:77:7:4:77.777TF., "01, .10f''.1.''FOM3,11777557.3F7DIT7'in4P1,77!'i,b!7 P, ''' - .7" - " 7477 37 1, 7r37 . Tr.F. 7 ! ,r,1 7. 1,1 4.k-o'! 5 '.=7" : :`; 3 7 , 7 1 ***4 A A* Tv.* *A A A *AA.* AAA 1cc 4, ft A 47 A.** A * * *AA****kk ;I:eckA* CITY OF ruKwILA. WA _ TRANSM3T ,k A 4, k * * * 4,. ..k * -A * ..t- :le 4-A-A A A * ..t.k TRANSMIT Number: R9800301 Amount: 118.76 06/13/00 13:10 Payment Methud: CHECK Notatiol: DANIEL GARVIDA init: T1.0 ................................................._....._..__ ....._......___........._____-____________ .......__._ Permit No D2000-188 Type: DEVPERh DEVELOPMENT PERMIT Parcel No: 022340-0070 Site Address: 541 INDUSTRY DR • Total Fees: 118.76 Thi's..Payment 118.76 Total ALL Pmts: 118.76 Balance: .00 itic k*Itit*hie**$‘1 1 .*********-kivAikilik -A its%.47'tltir 4—A-A ***-Aik-k0,14,-Aik-kts A.A.Aic***-VA—Alt7t. Account Code Description Amount 000/322.100 BUT( DING - NONRES 69.25 000 / 34 5.830 PLAN CHECK - NONRES 45.01 000/86.904 STATE BUIIDING SURCHARGE 4.50 5119 06/14.1717 TOTAL 118.76 • ••••.•.... • 41•'•• • •. Itc•:••••,*••4•4 Emject: � r)CIi In Type of Inspection: •F,�CL 1_ - tiCi l�J Address: U , • � � D_.,ate called: '1 Co Special instructions: Date w C l- C C - ) - Lo a.m. P.m. Requester: Phone: Z_.(=Cc ' = t:Ci -y 1 • (c 7 cz, INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. n Corrections required prior to approval: COMMENT Ins r o Dat? ,94a 0 $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: lx 2.!_ >' 1. �..LL..:ui e t veUIKS.uwlr ";,.ett7liii Gk .zwn4Y� i �� i:1a GVd A; S.' 13.4444'li kg raaP a« sv� a eti.; r t t.ki J a nG . i i tt ' 0 ' z U O 0 - 0 I- IV ' Hi 0 , •Z ,, 0 C A OI z Project:e of Inspection: r l rlcc l " P - •l ? I I ■icj ` : ■1GIL1 Address: �d S f U L ( b T w L Date calle +cx. :J Special instructions: 7 1 (- ..t%.e r C.. . C c..... � ctucS{7�r <' ctl� '"-} Date wanted: CI - \ --- C�� a:m) p.m. RI quest en Phone: 5 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 ❑ Approved per applicable codes. INSPECTION RECORD Retain a copy with permit D 21)Lc.-1 sg COMMENTS: -"i //__.. /•n,t--- / / e ,-.1, �j rl /p 4,, 7/ (....;.:07,.../ try / / 2i-Ih- - c_.4- ia.l .; Corrections required prior to approval. $47.00 REINSPECTI( V FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: t :..... .F.C.,. e..: ia.: cdnlar. w. n�ta�tL.. sl t.. 7pi. �r. twsC, dsrbA{ ki+ a.: srewuzJ +:6S+;�kiariteL..d4� •., y� Y?� 1(+hiS?ik':iti:.'utd.hw . 1i4u�dl SUd�Ci. ril��ii+lbh. >�a,fi;.:l.u:wjlkn�r. �+s :r.:. N NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 INSPECT! Address; 5� 1 —1- In' Sp a instructions: Type of Inspection: �-�- ;e9 I,Oa l l*. -VQ(? Date called: Date wanted: Re uesteg r: Phone: �, i'� .•d :"5- Approved per applicable codes. 0 Corrections required prior to approval. COM ENTS: Date: 2.4 6 2 7 REINSPECTIOKFEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. l Date: I Receipt No: � f < � iii' u�u�iL.:' J: r;, �a.: �: r « sii:.:' iit �?. f.:.. �. �� i:. is ' � .«uM:: J r INSPECTION RECORD Retain a copy with permit PERMIT NO. (206)431 -3670 trx+ r. b• : nCkil4Sai ,e„ »k(:k:t�ctje4l�.G:.r s! t?, R .'1i;1+tiY".:arv.r tls. :ia.4..vssJ..�6:.i- .y'144 141. +i3} i L\ 1 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 _ 1 5 \ n��us Special instructions: ra ' i n . C r e alled: Date want `d: h^ m: - 5' VV p.m. R g3 -- SLL {l (206)431 -3670 I A Approved per applicable codes. j Corrections required prior to approval. COMMENTS: r/� �' (/SQ El $47.00 REINSPECTION FEE REQUIRED. rior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. I Receipt No: Date: ♦� ., �� .. �IJaa:9Y.1'{�W7' 2w.%Wa+il�Z� `1N '� .�'y'srll�]Yi��i^y�'ap ��'.l _'�ke."1SG..��Y�..' � �.'( iuiw.- I. J- �1.. k� 'r�rtN.ei:�K�1,JM4iYY,we��•.�.Y �.q .i' yy...'r,aw. - tits+ tix:,:iit a��Asa?t;ti'r. i+ a. M�: Yn 'iii5iY.1,.y4Y ukiWa"V '1i4tle3 i.4`iul. .ii�SOY,+s:Lg:4.r: 3 UO to co F J � N LL W O 2 �I LL Q ; N _v 1- W W O ui D O N. 0 t— W UJ Z E- - - O I1 z 1 v N O z Projectr"' GZn(i T of Inspection: rGv-r) Address. 1 TC Dr Date called: J ---7 - \∎ - 0 0 Special instructions: Date wanted: el R nester. C Phon t ^ C — S3 n ~ CUctsW INSPECTION NO. . CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 Approved per applicable codes. INSPECTION RECORD Retain a copy with permit PERMIT NO. (206)431 -3670 Corrections required prior to approval. COMMENTS: ./ s t 174 �;lrf �` El $47.00 REINSPECT N FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. I Receipt No: I Date: F _:.� �.�a` _;:i:'r..,.:.,.�.v...�: t,. .�s,.:c�>`• 4 Asa r n,....;. .waw.?..W ..i.i:��.,�Z �: Z> � _:...... ...;.�.... _,:..':�., ......�.... XtiA1;K45t? i :iii.N.4'sl6 v4 , Ao irii.l „iwv el�t: ti "AtGaua�,+3,.a.Jt• ..r� t2w7r:::v�Fa:a; INSPECT! • NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98 Project: 1""^ Y nr. Address: j " % , /t.) Special instructions: • COMMENTS: Inspe ; I Ott a re ' INSPECTION RECORD Retain a copy with permit Type f. Inspection: S7I If) Date called: Date wanted: Requester: Phoye: PERMIT NO. (206)431 -3670 a .m. (p.m. -23c) �5 Approved per applicable codes. tions required prior to approval. Viier ec6c. $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection. I Receipt No: I Date: p. ... r ^•x` S41:3 , txhi Sn , 4s Suw.. 4, ac 7a..mstosmak±`at:uJa' "vsx�.c W CO 0 to W W J p co u . O g N • om; 1— w z P w w : U D i t : 0 1 —'' =V u. 10 IL z Project: — Tat rd LA .Type of Inspection: I cam) « -Ct Address: 5L\\ •end0s+r9 br Date called: 6, -, o- Dc Special instructions: Date wanted 6 .,._ ?:-/- 0b P.m. Requester: srTh Ph e: _ O 3 .r S T W INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 PERMIT NO. (206)431 -3670 Li Approved per applicable codes. Corrections required prior to approval. COMMENTS: u /A.9tL. Zoe ALSO E-66crgic .4-c- e Insp . /e4vd Dat6, g7 0 0 $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: > � ���f� `.+�I�i�a`t.fel •1« : �iaw'•' 31C"•' Gw' 16'$ tL1+:. �i: a: t,: a,. Li. tSikf .:w.'C- ?.r:.,".':.'.e�ra�m° sl.dlidt3ik'.i.i dly2sL.S, wil. r6i,AKiti titI a.:a$bai`llil[ • Su'4i ' +ta, t`k� 'GStic1�IGLcA "r. rasc•e bltiV+,4€Sv,7,', ` AA/.. z o O. coo` to W N W' w } O } c �. = W z � I- O Z !— ul UO o w w` tii Z O F" z Retain current inspection schedule / _ � Needs shift inspection Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: Approved without correction notice Approved with correction notice issued Authorized' Signature Date FINALAPP.FRM T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-4439 Project Name h y Address S` /1 .11. ,4. ,;; '' .. slt..'iti ..R:a..7aF t1 ;; . e. � 1.-+. .: i �f p.,"- �� �. -T. . City of Tukwila John .W Rants, Mayor Fire Department Thomas P. Keefe, Fire Chief TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM y r Permit No z 1 w U OO 0 W J • u. in 0 D. a I- U- i Z F.. I. 0 z I IIJ U� off Ill = U I- H ui U -± O 1- z ilk PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D2000 -188 DATE: 6 -13 -2000 PROJECT NAME: TANDY SITE ADDRESS: 541 INDUSTRY DRIVE SUITE # XX Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: Fl t - A) l Div is ion ` � Fire Prevention PI nning Division s� wC.� 1p' mac, 010 n]C\ (D Iu P � W it t 624.Z Structural II Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete TUES /THURS ROUTING: Please Route Structural Review Required \PRROUTE.DOC 5/99 Comments: DUE DATE: 6-15 -2000 Not Applicable n No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: (ten days) DUE DATE: 7 -13 -2000 Approved n Approved with Conditions DZ1 Not Approved (attach comments) n REVIEWER'S INITIALS: Kell DATE: (D tE tD CORRECTION DETERMINATION: DUE DATE Approved n Approved with Conditions n Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D2000 -188 DATE: 6 -13 -2000 PROJECT NAME: TANDY SITE ADDRESS: 541 INDUSTRY DRIVE SUITE # XX Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Is Issued DEPARTMENTS: Building Division ` Public Works n Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete Comments: TUES /THURS ROUTING: Please Route n Structural Review Required n No further Review Required kil REVIEWER'S INITIALS: (-..- DATE: APPROVALS OR CORRECTIONS: (ten days) DUE DATE: 7-13-2000 Approved n Approved with Conditions REVIEWER'S INITIALS: CORRECTION DETERMINATION: Approved n Approved with Conditions REVIEWER'S INITIALS: \PRROUTE.DOC 5/99 Planning Division Permit Coordinator a DUE DATE: 6-15-2000 Not Applicable n Not Approved (att ch comments) n DATE: 1 Z DUE DATE Not Approved (attach comments) n DATE: -C4 tii 00 coo w ` w 0 , gQ ILI z �l zo ui 0 - 0 I- w U. O _co 0 z tiR DEPARTMENTS: Building Division Public Works Please Route Approved 1PRROUTE.DOC 5/99 TUES /THURS ROUTING: REVIEWER'S INITIALS: REVIEWER'S INITIALS: PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D2000 -188 DATE: 6 -13 -2000 PROJECT NAME: TANDY SITE ADDRESS: 541 INDUSTRY DRIVE SUITE # XX Original Plan Submittal Response to Incomplete Letter # Response to Correction. Letter # Revision # After Permit Is Issued CORRECTION DETERMINATION: Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete ri Incomplete Comments: n Structural Review Required Approved with Conditions Planning Division n Permit Coordinator No further Review Required n DUE DATE: 6-15 -2000 Not Applicable n n DATE: APPROVALS OR CORRECTIONS: (ten days) DUE DATE: 7 -1 3-2000 Not Approved (attach comments) ri DATE: C/ /6 7 G) DUE DATE Approved n Approved with Conditions ( I Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: z U 0 ; N 0 W I J H W 0 2 g a' O H u z z0 U O N tu W' I 1 - -, - O! . . z . , o u) z ACTIVITY NUMBER: D2000 -188 DATE: 6 -13 -2000 PROJECT NAME: TANDY SITE ADDRESS: 541 INDUSTRY DRIVE SUITE # XX Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: Building Division Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete PLAN REVIEW /ROUTING SLIP Structural Incomplete Comments: TUES /THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: (ten days) Approved Approved with Conditions REVIEWER'S INITIALS: CORRECTION DETERMINATION: Approved \PRROUTE.DOC 5/99 Approved with Conditions Fire Prevention n REVIEWER'S INITIALS: Planning Division Permit Coordinator No further Review Required DATE: Lia " l 00 DUE DATE: 6-15-2000 Not Applicable n DUE DATE: 7 -1 3-2000 Not Approved (attach comments) n DATE: DUE DATE Not Approved (attach comments) DATE: ACTIVITY NUMBER: D2000 -188 DATE: 6 -13 -2000 PROJECT NAME: TANDY SITE ADDRESS: 541 INDUSTRY DRIVE SUITE # XX Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: Building Division Public Works PLAN REVIEW /ROUTING SLIP • Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Please Route o ne j � TUES /THURS ROUTING: REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: (ten days) Approved n Approved with Conditions CORRECTION DETERMINATION: Approved \PRROUTE.DOC 5/99 Incomplete Structural Review Required Approved with Conditions REVIEWER'S INITIALS: Planning Division Permit Coordinator n n DUE DATE: 6 -15 -2000 Not Applicable n No further Review Required REVIEWER'S INITIALS: DATE: -zz -pc n DATE: -1 'oo DUE DATE: 7- 13-2000 gEecL._ Not Approved (attach comments) n DUE DATE Not Approved (attach comments) n DATE: JUN 15 2000 TUKWILA PUBLIC WORKS Fire Department Thomas I? Keefe, Fire Chief Fire Department Review Control #D2000 -188 (512) Re: Tandy - 541 Industry Drive June 19, 2000 Steven M. Mullet, Mayor Dear Sir: The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. Maintain fire extinguisher coverage throughout. Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5) 2. Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 1207.3) Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (UFC 1207.3) Aisles leading to required exits shall be provided from all portions of buildings. Aisles located within an accessible route of travel shall also comply with the Building Code requirements for accessibility. (UFC 1204.1) 3. Maintain automatic fire detector coverage per N.F.P.A. 72. Addition /relocation of walls, closets or partitions may require relocating and /or adding automatic fire detectors. Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206.575 -4404 • Fax: 206- 575.4439 Antle � t11 . g City of Tukwila Fire Department Thomas P Keefe, Fire Chief z tom c6 W 0 U O' y 0 : N W co 9 u _ ui 0 All new fire alarm systems or modifications to 15 existing systems shall have the written approval of U. Q` The Tukwila Fire Prevention Bureau. No work shall = n c until a fire department permit has been i W ; obtained. (City Ordinance #1742) (UFC 1001.3) ? H O Call the Tukwila Fire Department at 575 -4407 for zf approval of any system shut down. Have job site • 2 m a name and the Tukwila Fire Department Job v Number available to confirm shut down approval. (City .0 Nf9 Ordinance #1742) Of- W W o Contact The Tukwila Fire Prevention Bureau to witness 1 all required inspections and tests. (UFC 10.503) u.O (City Ordinance #1742) iii z : U u) 4. All electrical work and equipment shall conform p i, strictly to the standards of The National Electrical Code. z (NFPA 70) 5. Required fire resistive construction, including occupancy separations, area separation walls, exterior walls due to location on property, fire resistive requirements based on type of construction, draft stop partitions and roof coverings shall be maintained as specified in the Building Code and Fire Code and shall be properly repaired, restored or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (UFC 1111.1) 6. This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Page number 2 Steven M. Mullet, Mayor Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206 - 575.4404 • Fax: 206-575-4439 + rs.^ T- �t- ww.++ttT.n+rM�yWMSir.+caaTnM City of Tukwila Steven M. Mullet, Mayor Fire Department Thomas P. Keefe, Fire Chief Page number 3 Yours truly, 11i The Tukwila Fire Prevention Bureau cc: TFD file ncd Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206 -575 -4404 • Fax: 206 -575 -4439 : , .; • REGISTERED, AS PROVIDED BY LAW AS CONST CONT GENERAL REGIST. # EXP.. DATE CCO1. DVGCOI *011PL 09/20/2000 EFFECTIVE . ,DATE , • ; 10/13/1999 -D V G CONSTRUCTION INC 12038 SE 169TU -PL RENTON WA 98058 Signature r Issued by DEPARTMENT OF LABOR AND INDUSTRIES • • •, • • • • PROJECT NAME TANDY 541 INDUSTRY DRIVE TUKWILA, WA same PROPERTY MANAGER. HALLWOOD arIMERCIAL REAL ESTATE 617 - INDUSTRY DRIVE TUKWILA- VA 98188 C202.6) 575-6675 It FAX (206) 575-1415 SCOPE Cr WOW. MOM WALL ADDITION AT WAREHOUSE AMA, INSTALL ADDITIONAL SUSPENDED CEILING, 7AX/PARCEL P WAIRMNIMIMINK, TYPICAL PARTITION _ UNIT 535 UNIT 537 o5tiriff0• 3 swam AC.T. MUM 141-0 STRIL-TUSE • AS NOTED ON PLAN ABCfrE STL- DECK, FAsTal AttcHOR TO DECK W • (4, iTE-T4 SCREWS COWPOCOS METAL EDGE coar.tsko WINER. SECURE TO �O .OF AT 24 O.O. fiTM... SILOS AT 24' 0.0. rtp.0.11.0. GWEt. RUETER BASE POWER FASTENER AT 2 0.0. ROOR AREA CF IMPROVEMENT UNIT 539 102' 6 UNIT 539-IA UNIT 543 UNIT 541 BUILDING 3 FLOOR PLAN 4 I UNIT 545 oot \ LATERAL BRACING UNIT UNIT 547 549 UNIT 551)3 UNIT 551A D2D0D I Vra PTV M. POWER ACTWATEO FASTENETTS VPLIEO F PULLOUT cqz c.A. WIRE AT DO MOM EAC-I OTHER AT 12 O.C. MK/ r OF VERTICAL SUPPE:GT /COUSTrAL CEILING S AT T ATTAIN Stu° ELMER AT 24" 0.0. NON-Li:WED P/JOO1ON Fi r • p 02 , . Dry OF T APFROyED "'" JU N 2 2 2001 As No rEL, BY _ _ oi zE)3, fir-'6FfrIt No. .• : _ - D2000- I 88 1 SEPARATE PERMIT REQUIRED FOR: ECHANIcAL [ 0 PLUMBING 0 GAS PIPING CITY OF TUKWILA BUILDING DIVISION anTA JUN 1 3 2000 PERMIT CENTER LEGEND GENERAL NOTE& EXIST/ WALLS WALLS TO BE DEMOLISHED NEW WALLS COSTING WALLS 3-1Ie STEEL STUD, 56.1P GW3 EACH SIDE MOUNTED TO BOTTOM OF ROOF (FULL HEIGHT) EXISTING WALLS 3-1/e. STEEL STUD, 5/8' GW3 EACH SIDE WONTED TO BOTTOM OF ACOUSTICAL CEILING NEW WALLS 3-I/2• STEEL STUD, 5/8 GWB EACH SIDE RIL HEIGHT MOUNTED AT BOTTOM OF ROOF DECK WALLS TO BE DEMOLISHED 3-1/3" STEEL STUD, 5/8' GW3 EACH SIDE MOUNTED TO BOTTOM OF ACOUSTICAL CEILING L ACOUSTICAL CEILING TO REMAIN. ADD PER PLAN, REPAIR EXISTING AS NEEDEA HvAc WILL RENAIN. ADD AND EXTEND SUPPLY PER PLAN SUPPLY AND RETURN WILL NOT BE MOVED a ELECTRICAL LIGHTING TO REMAIN. ADD PER PLAM REMOVE ANWER RELOCATE OUTLET AS NEEDED 4, ALL NEW DOORS MUST HAVE LEVER TYPE LOCK 5. ALL NEW ROOMS MUST HAVE SMOKE/HEAT SENSOR B 10' WAREHOUSE 111111111111111111 OF ICE MNIM 1111111111111111111111 RO 11111111111 lo■ RES I OM OFFICE WAREHOUSE C:) OFFICE 12' 2' OFFICE 20 OFFICE 73. RECEPTION AREA '-4 Jii REST 5' ROOM EXISTING DEMISING WALL 40' 2' FLOOR PLAN OFFICE 9' 10 OFFICE \IT 541 iN ACOUSTICAL & ELECTRICAL PLAN cmnAummA JUN 1 3 2000 Paw CENTEA