Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D2000-330 - FIRESIDE - WALLS AND CEILING
FIRESIDE 13028 INTERURBAN AVE S, #124 D2000 -330 City of Tukwila Parcel No: 000480-0017 Address: 13028 INTERURBAN AV S Suite No: Location: Category: AOFF Type: DEVPERM Zoning: C /LI Contractor License No: GWINNMCOO7KJ Permit Center Authorized Signature: Signature:_ Print Name: DEVELOPMENT PERMIT tocif Atierti\„. (206) 431 -3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES, APPLICANT IS PROCEEDING AT THEIR OWN RISK. Permit No: Status: I=sued: E >•:pire:,. D2000 -330 ISSUED 10/20/2000 04/18/2001 Const Type: Occupancy: OFFICE Gas /Elec.: UBC: 1997 Units: 001 Fire Protection: SPRINKLERED. Setbacks: North: .0 South: .0 East: .0 West: .0 Water: 125 Sewer: TUKWILA Wetlands: Slopes: N Streams: OCCUPANT FIRESIDE Phone: 13028 INTERURBAN AV S, SUITE #124, TUKW OWNER TIME DC INC 3470 MT DIABLO BL #A -100, LAFAYETTE CA CONTACT ALAN BYLSMA Phone: 206- 433 -8997 12720 GATEWAY DR #116, SEATTLE, WA 98168 CONTRACTOR GWINN MANAGEMENT CORPORATION Phone: 425 -265 -1198 PO BOX 77624, SEATTLE, WA 98177 * kk• kk*• k: k• k•. kk•k*** *k•k*k•k•k**** *•k*• *** k* k* k: i kk* k*• k*k• k: kk* kkk**** ** *kkk*k***kk•krl:k•k•k***kkkkk Permit Description: DEMOLISH EXISTING INTERIOR NON• - BEARING WALLS & CONSTRUCT NEW INTERIOR NON - BEARING WALLS & NEW SUSPENDED ACOUSTICAL CEILING. k **k•k•kk**** ** *Akk* * *•k* t**k *k * *k*A *k* **A k: k** k• k** k*****: k: k k *** ** *•k*** *k*•k** *** * * *kk:kk Construction Valuation :: $ 18,000.00 PUBLIC WORKS PERMITS: "*(Water Meter Permits Listed Separate) Eng. Appr: Curb Cut. /Access /Sidewalk /CSS: N 'Fire Loop Hydrant: N No Size(in): .00 Flood Control Zone: N Hauling: N Start Time: End Time: Land Altering: N Cut: Fill: Landscape Irrigation: N Moving < Load: N Start Time: End Time: Sanitary Side Sewer: N Nn: Sewer Main Extension: N Private: N Public: N Storm Drainage: N Street Use N Water Main Extens ion N Private: N Public: N It* * *** * ** ** * *** * * * * ***k ****Ik**: l******* k • k• k• k• k** ****•k*** *•kk*** ****k TOTAL DEVELOPMENT PERMIT FEES $ 488.36 ** k*** k*******• k******** **** ****k* ** * * * * *:k**; ** **:kk ** *****: k** * *•k* *•.k *•k *•k ***** *•k* ****•k* Date: _LO .211 � I hereby certify that I have read and examined this permit and know the same to -be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other state or local laws, regulating construction or the performance of work. I am authorized to sign for and obtain this development per r t. Date: This permit shall become null and void if the wort: is not commenced within 180 days from the date of issuance, or if the wctik is suspended or abandoned for a period of 180 days from the last inspection. • 0 0 co o co La w w 0 g:7' 1 th I- w z 1-0 z1 la a 0 -; o H= w ` • LL H O ; ii z = ': 0 Signature: Address: 13028 INTERURBAN AV S Suite: Tenant: Type: DEVPERM Parcel #: 000480--0017 Print Name: CITY OF TUKWILA Permit No: D2000•330 Status: ISSUED Applied: 10/04/2000 Issued: 10/20/2000 *A**AA** Permi Condition: 1 . No changes w i l l be made to the plans unless approved by the Engineer and the Tukwila Building , D iv i si on . . Any new ceiling grid and f ikturi'-,insta 1 1 at i on is required to meet Aatbra 1 bracing requirementS, for Seisinic Zone 3 ' Parti t on wa 1 Is 'at tacheC.to •ceiling, grid inust be fatra 1 ly braced if over eight (8)- feet in length. !, , 4. All construction tobe done in„.conformance .Wi th approved plans ehd: redehts of the Ohl forth Bui 1 d in4 '''Code (1997 Edi amended, Uniform :%Mechanical Code (1997:Edit ion) , and Washington State Energy'',C6de' (1997 Edition) 5. Validl.ty of Permit. The ,i'ssuance of a permit 'or approval of plans?/ specifications, .nd 'dPmPu„tetions shell not be- strOed to, be, a permit f or, or an ePProva 1 of, any v'1016t)°,11/, of iany of the provisions ofJthe building code or Of ank- other 01Tlinn6e of the Tor Sd 1 ct i on. No permi t presuming to g ikC authority to ,vi olate or cancel the Provisions of t h i s s fA s , , , .00-tle shall- be valid. , perki'ts- shal 1 be %obta ned through the Washington State Division of -Labor,and and all electrical work wily-, be nspect ed by tfia,t, agency (248 There shall be no:fbccui; ahc lding(s) until the. final inspect has ''beeni comple by the Tukwil Bu I ld 1 ng Inspector. • Al 1\ prchanf6a1 - work sha 1 I be under separate permi,t tssiled by the City of Tukwila. , 9. VENTILATION IS REQUIRED FOR ALL NEW ROOMS AND SPACES OF NEW OR EXISTING BUILDINGS IN CONFORMANCE WITH THE , UNIFORM BUILDING''' CODE AND THE WASHINGTON STATE VENTILATION AND INDOOR AIO QUALITY CODE, CHAPTER 51-13 *0 , hereby certify tIat 1 have read these conditions and will' comply , . with them as outlined . A11 pr-ovri s ons of law and ordinances govern ing this work will be comPl ed with, whether :specif ied liereln or not The granting of this permit presume to give authority to vl o 1 a te or cancel the provisions of any other Work or local l aws regulating constpqction or the perfOrMan66 of work. Date: Project Name/Tenant: ` . r S i Vr 8 ltoos�uuOn: Site Address: Ci State /Zip: i 02-0 I -¢ stA.v f tre 1 . * iz.y Tax Parcel Number: oob.4Ba -60(7 Property Owner: t fL J ma.' 1S Co, Phone: �D(D- I - I I03 _r�L. Street Address: t 0 S e Citq State/Zip: t z. "2 7.0 c�, - .e logy p D. 1 i .� . WA . Fax #: � A41- a 9 I Contractor: Phone: Street Address: City State /Zip: Fax #: Architect: /^ • b a. 0 l Kai/ A I 4 . ,ec -- Phone: 2 oG - '� 33 -- g447 Street Address: City State /Zip: i 7.7 2 to Cca4 -e. way P r, '#/!6 Sea_ Fax #: 2 e 6 - ZK,6 -- s 34.7 Engineer: / Phone: Street Address: City State /Zip: Fax #: Contact Person: A l f a� -� Phone: zo - if 3 - y /5 Street Address: City State /Zip: iZ -7 ZO Ct-a. Dr_ # it(� , h . (4 ). qd i6l3 Fax #: -z..0 U -' Z 6 - 8 -- C q Description of work to be done: a 0.e vK o l t ; ti ¢ k 75 + I A i a - 4-e via o Novi- to e-a v I wa <( S.) 4Gdr►y-ErNO4 ,,,2,..) IN .e.✓ r.OVe o'1—b 24V'I& ! W4i(IS k fit1r -iv 9 /0 . 0. -d C I t� Existing use: El Retail El Restaurant ❑ Multi- family ❑ Warehouse ❑Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel rg Office ❑ School /College /University ❑ Other Proposed use: ❑ Retail ❑ Restaurant ❑ Multi- family ❑ Warehouse ❑ Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel Ca Office ❑ School /College /University ❑ Other Will there be a change of use? ❑ yes no If yes, extent of change: (Attach additional sheet if necessary) Will there be rack storage? ❑ yes no Existing fire protection features: sprinklers ❑ automatic fire alarm ❑ none ❑ other (specify) Building Square Feet: 15 00 4 .4 existing Area of Construction: (sq. ft.) 2 . e 6 D Cc. i Will there be storage of flammable /combustible hazardous material in the building? ❑ yes a no Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets Date ap c: • t-r� ^ Dale app Icatlpn�e�lr / " 1 1 Appl' •r taken by: (initials) II UU AP CITY OF TUK ILA Permit Center 6300 Southcenter Blvd., Suite 100, Tukwila, WA 98188 (206) 431 -3670 OR STAFF USE ONLY Commercial / Multi - Family Tenant Improvement / Alteration Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. APP,LICANT.REQUEST F.OR PUBL`•IC WORKS SITE/CIVIL PLAN REVIEW OF THE FOLLOWING': c(Additlohai reviews maybe determined by th'e Public Works: Department) > . ❑ Flood Control Zone ❑ Hauling ❑ Channelization /Striping ❑ Curb cut/Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: Size(s): 0 Cut cubic yds. 0 Fill cubic yds. El Landscape Irrigation ❑ Sanitary Side Sewer #: ❑ Sewer Main Extension 0 Private 0 Public ❑ Storm Drainage ❑ Street Use ❑ Water Main Extension 0 Private 0 Public ❑ Water Meter /Exempt #: Size(s): 0 Deduct 0 Water Only ❑ Water Meter /Permanent # Size(s): ❑ Water Meter Temp # Size(s): Est. quantity: gal Schedule: ❑ Miscellaneous ❑ Land Altering Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. PLEASE SIGN BACK OF APPLICATION FORM CTPERMIT.DOC 1/29/97 AMd!?tl.'�i�n hli BUILDING OWNER OR AUTHORIZED AGENT: Signature: /y, (41 ` Date: 0 q(00 Print name: A. I 1. Phone: (Q — 9, 3 -i - N�7 Fax #: Address j Z 7 I � m, Q u p v, 41 , . I I City /State /Zip 4 to, 9 6 i b 8 ALL COMMERCIAL/MULTI ILY TENANT IMPROVEMENT / I ERATION PERMIT APPLICATIONS MUST BE SUBMITTED WITH THE FOLLOWING: D ALL DRAWINGS TO BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT, STRUCTURAL ENGINEER OR CIVIL ENGINEER > ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN > BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A SUBMITTED ❑ ❑ Complete Legal Description • ❑ Metro: Non - Residential Sewer Use Certification if there is achange in the amount of plumbing fixtures (Form H -13). Business Declaration required (Form H -10). Four (4) sets of working drawings (five(5) sets for structural work), which include : �y ❑ Imo- Site Plan (including existing fire hydrant location(s) 1. North arrow and scale 2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements 3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions 4. Location of driveways, parking, loading & service areas 5. Recycle collection location and area calculations (change of use only) 6. Location and screening of outdoor storage (change of use only) 7. Limits of clearing /grading with existing and proposed topography at 2' intervals extending 5' beyond property's boundaries 8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of use only) 9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of those, identify by size and species which are to be removed and saved 10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change of use only) 11. Location and gross floor area of existing structure with dimensions and setback 12. Lowest finished floor elevation (if in flood control zone) 13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form H- 9). ❑ Floor plan: show location of tenant space with proposed use of each room labeled ❑ Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of any hazardous materials; dimensions of proposed tenant space. ❑ • Vicinity Map showing location of site ❑ Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of rack. Structural calculations are required for rack storage eight feet and over. ❑ 71 Indicate proposed construction of tenant space or addition and walls being demolished ❑ LI. Construction details II ❑ Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of water supply to sprinkler vault with documentation from contractor stating supply line will meet or exceed sprinkler system design criteria as identified by the Fire Department. 2 ❑ Washington State Non - Residential Energy Code Data shall be noted on the construction drawings. El ❑ SEPA Checklist - if intensification of use (check with Planning Department for thresholds). 71 ❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other land use or SEPA decisions. Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County Department of Public Health prior to submitting for building permit application. The Department of Public Health is located at 201 Smith Tower, Seattle, WA or call (206) 296 -4787. (Form H -5) ❑ ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no contractor has been selected at time of application a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent if the applicant is other than the owner, registered architect/ engineer, or contractor licensed by the State of Washington, :a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal 1 HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PE CTPERMIT.DOC 1/29/97 w:`✓ 47.4 ,S .4.41.6,ka..,'. 1.1:14 ra a.ic+, a:alaa z w CL 6 00 U) w J F- w - u CD = w z I - z I- W w U rn 0 1- Ww w z U= O ~ z t��1y 1 �1 �'�NQ •fir .��f��('w A***A4.IV1 *kk *A.* *•teA 'A *.4• >; 4 * * *,4k.l. *h4-4 *AA *ode A4 # *•kit4,4 **• *4•*�A..ko * *• r It � i� la z 'r r]T',.OF. TUKWII_A, :144 c * *11 * *'.t *�k'A' * * * * *• * *1ti *'h *k• *d * * * r ,k.,* .:ti * Ak *•fi *o4�•* * •+:i.• :4 *@** .1.* * * . T1211115141'1' 11urnh't,a It3Ct)O3'I3 Amount: 297.75 10:20/O0 1():52 i'aiym erit i+f l hr. da CI•IECI( Nr.:tat iarla 1: :] uv' [)UMMC PJ Tn lt: TLI M Permit Not ; 1.)20()0 -930 Type CI VPC.RM I)E.VEL.I:'FMENTF'CF'M]:T hare" l< No: 000430...0017 Si.t'e 'llddressa'"13028 ]''1'tERURBAN AV 9 Total Fees: iL3r,36 Th "i is Ptiymerct . ."97.75 Total AL.L Pmts u 4 GO.3 6 11 i ance : Q * 4- A* I4A• * *4 *A *4 *- } ; *4 *4d: *.A44:4* 4.de dr*,% /V A. *�4 * *7 *A *** -0 *S*•- ielk*d'dl#it Acraun t. I Des :r i pt i a n I3iraunt 000/322. 1.00 t UT.I. ilOtiORES `293.:. } °; O00/386 904. STATE. " BOILDx140 - SURIMitI i.; 4.50 9169 .1.0/2 97 :3. TOTAL, 297.75 s:rN: 711 j $ <y r`,'a':'•l i {il�'j • sa l i � (�! .yf,,l!i.. i .a r rid r�.t i . 1 r u ;.�.a �t� tlt .... fk. F. r�r5 tYn.�:.. -� ..a;:F,f a.U� r. _. ..4. m- m,X•.;u,. e.rt+r 'x.�7c� 1k •h l•k rA•1•k':F.' A•k kkA+• A•k k * *** k•As4 *41l ' ,tkl. •k•A*:l k:1 *A d•k 1:k:l k^4kA•k**:l 'ir k � A'.!' A . CITV qt. TUI(WILft, wa Q QP -. 3C3' TP. ►14SMIT k ,l •k ;tti;e1 � * A• • :F .l• :4 4 it .; • �l * s1 1L :1 :k :i' k .l 74 !r 10- :k (. Nlar P9(3r'0t +9 rt0i. 10/ 04(.:11 4:r 14Pav Me± lia�,l „ G1�1_"1i ido ion : gtaV 1p 1; 1:111 E I r► t L: } +Q.ts� I)IzVPEM11 I) Vf�1 Ofll4f�t�7 Cfit4'( fxar^cel- P1n:. t)u 1 04i30..�)Oi i r i:te A'ddl�ers� '02uIh7'ERUI1BAN AV ti ** * * * * *14>t4 *11' *1l *11.11 74114*114 * * ** F * * * *1 *•k.k..4tt *lt* *•4**!b rour►1• :Code Desct- i pt ion 00t345.830 tIGr` PEP This aymertt yv > ri- ?� -••ts ti: _1 Total Fen 190.6 Total (41..1._ (' a Balance: tis !u: 190..61 •297. ***I% * * * * * * t0o u n 190.63. 0;43 10/05 9710 TO AL Yi'u 7 'ni'a ^�L•"°x� °L'R yr tea. v �,��:a�: r 3'� M ''•� n fi." ` n"b�Ya 1' t X4;"5 +,'`^'r'� a, :�. i� - {..,: ST 4b ∎r,' "'.Ak3 u1, ; �S: =dif,' r•k.:sry ..w:i, ,.ie ev:i.4..u Project: Typ f -Ins ec i U Address:/3w8.. ii1 J'•V ✓,b «n (ic.5. `Bate- / / ? /v/ Special instructions: j r,/ r �C.: /? V toc /20/C . / \ . Date wanted: l /a 3/ Ca_ .�m1. m)) Reque er. Phone: a& - ass - Y'l 4 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwile,"WA 98188 pproved per applicable codes. INSPECTION RECORD Retain a copy with permit PERMIT NO. (206)431 -367 Corrections required prior to approval. $47.00 REINSPECT jbN FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. COMMENTS: Receipt No: Date: it iALiauk3n+ 1 ^useerl t: G • ' `:1"'"` t ,Y:. w ta * .0`01 *.s,:. rxoar.Leotia ;r ` nt r , cr zirs 4t „ A1:1�l- .ul.n.. ».. �tkcx l.e •• , wa, ldr�a ..wMw.,r.. a94+ . t vwr .. .: ' 4n , se : i -,+: 4, '"+lr ..t.x .:∎ :41;.4* , ,.;;irai'_,usw•tw:un = ' Ur moo” 'CO 0 W ILL w 0 to a, O' Z 1- 0 Z ` _ ' z Project: Type-of Inspection: V Address: /3 /i : 09F r be- �3. Date galled: ///Wiil Special instructions: V (/I `l (a c1 1 £ dfuU : AAH Dat ant d: �9 a.m. p.m. Requ st r: Phone: INS� '.dCTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 Approved'per ai5plicable codes. COMMENTS: i ce <,..< }1iPPr. S 1, r' s4q rr 1V\ re e -Pro k l 4 I uyn\r1ct't I cj V\ aA a ver 9c€ door kpoc h �. 4 e Inspector: Date: $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: (206)431 Corrections required prior to approval. I'41f 5vh'4LP.h 4;i . d wadi+ Project: --- hYcs/ Type of Inspection: Sys /Acted Cz Address: /31)8- /p *rturbarn 5. Date Called: 11Sl fro Special instructions: Sl/i Y{, ,' it 40C rj a 6"0111 - (4414 AA H 4011 b Date wan ed: / /8't a.m. p.m. Requg3ter: fS 0' Phone: ,9 o6, - ass - c g-G9 i/VD-330 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 Approved per applicable codes. Corrections required prior to approval. COMMENTS: Date: n (206)431 -3670 $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: 7 'r"kiglrAttli. —VDS1 .9,4:r • if.' .ts_ea °' 1:1ftS, �i: ^Ba:Si 4 .il.u!L 1. k. :K�i+d.AiS I.Jlyil'kG . .A *. i;�iov� .at /..,..'h Project: � JYeSr Typepf eCtion: Address: /3029 J rr J e, -r'r . Da alled: f 2 —! Special instructions: to 12 (4 Lock oytF'ral _ r KI t 1� IS C- CIYYl6'Y1cific i Date wanted: IZ rI5 -v p.m. Requester. ��� Pho e: (20(0) 25 ciEf1 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 9818 PERMIT NO. • (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector.. Date: g c 00 $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection. Receipt No: Date: 116x6'a ": feakt..lvaguatro)41- r'Sattot i, ltt4litiu''svi( &i��.SdP.I 'u =T�Tm ,Nk'.4� ;'rn� 'Fu''NF.;Aba" ti 'j •'.=` +S °z ...:i:'!�. i'.4:rw *la* itek+si[k.Ew+4 L ^• da: uU.•% ev+ 00d- 4;iA4`�a+araAwes?..a.4Sl.aol �_.1,.)X,9n.,fi.X.tiq vtr2a.[. �Yi4Sk+ n ..wc�bak'�n�1rNaSX..x+,fi:iMw;a <f...nb'kUTi�»r..os.�.;%:. Project: —...., — res ` �� itt o spection: ra vilicler Address: Si e (2.4 13o S k ert&r6M1 S. Date called: a -/Z -OC Special instructions: LOC.k cki f ran 1 F 15 Gdm�X, ' 4 l ee4-mii �l,s rre\ Date wanted: 75.m. )7. - i 3 - 00 m. Request yr P h o) ass - 9s>,36 og, o INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 9818 Inspecto Approved per applicable codes. Corrections required prior to approval. COMMENTS: sr (-7-1) Fr h \.q �1rr e ( »v► 1 C e ga - erylrnv'tJ / `\ cowp) k' Gc.XIC U01 Or Pr -P r klAe '1 C+( 1 Y� 1'1.0 /X 1->e r\'‘t,cA 0 \0 tom 11 -i? 0,K r)4 Q c cer Date:1:Pi_I — 6y On n $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: e ' § 1?,��,'F,,, 3 ,4sgai 1} vf. k. 1' g '>. ti `Y.§'k ' �ea�w'. a. wae.. ae:,.I.,�..i2;ax,:`c3.►.r'.tirr. ,.,.. ,.,w,;i:.uca.,i+e..:.i.xidrt�IN J.�.r >� �+...� t + dr,,:, b��is. Ar »iPi;.Lt,.,...ai,;de: �W i U U O w o, WW u. W O 2 g J. IL Q CO = di Z W U 0 ' O ;0 1- W W Z H til Z W z Approved Approved Sprinklers: Fire Alarm: Hood -& Duct: Halon: 'Monitor: Pre -Fire: Permits: u i.. .► ; -:.;; I;.�iP'�'K� �,'ti 4.� . �f�Ki;++; �. tc ": •1,.4{:'y rvt,s�<: YI .1L.:fe1.:4., =h;. ���j�vt ` Y.,�v,► " r��w3�rwi'�: Authorized Signature FINALAPP.FRM City of Tukwila Fire Department , TURWILA- FIRR,DEPARTMENT. ,FINAL APPROVAX, •FORM Retain current inspection schedule Needs shift inspection Ft\ without correction notice with correction notice issued s �� T.F.D. Form F.P. 85 il\C6,\6\ Dat John W. Rants, Mayor Thomas P. Keefe, Fire Chief Permit N O aoc- 330 0 05 zl \ c Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) .57.5-4404 • Fax (206) .575-44.39 DEPARTMENTS: Build ing Division ,VII AWL 1D -6.0 Public Works 916 MA. 1D -51:0 Comments: VILICJUII.IMC PLAN REVIEW /R ��ING SLIP ACTIVITY NUMBER: D2000 -330 PROJECT NAME: FIRESIDE SITE ADDRESS: 13028 INTERURBAN AV S DATE: 10 -4 -2000 SUITE NO: 124 XX Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued Fire Pr vention X Atvc. L040 Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete n n TUES /THURS ROUTI G: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: (ten days) Approved n Approved with Conditions REVIEWER'S INITIALS: CORRECTION DETERMINATION: Approved Ti Approved with Conditions REVIEWER'S INITIALS: Planning ivision I_ i Permit Coordinator No further Review Required DUE DATE: 10-5-2000 Not Applicable n n DATE: DUE DATE 11-2 -2000 Not Approved (attach comments) DATE: DUE DATE Not Approved (attach comments) n DATE: W J U: O CY W CO u_ W 0 LL 7.3 N = a w z o F- 0 0 : O I- 111 w0 w z 0 ~' z City of Tukwila Fire Department Thomas R Keefe, Fire Chief Fire Department Review Control #D2000 -330 (512) October 6, 2000 Re: Fireside - 13028 Interurban Avenue South, Suite #124 Steven M Mullet, Mayor Dear Sir: The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. Maintain fire extinguisher coverage throughout. Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5) 2. Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 1207.3) Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (UFC 1207.3) Exit hardware and marking shall meet the requirements of the Uniform Fire Code. (UFC 1207 -1212) Internally illuminated exit signs shall have both bulbs working at all times. (UBC 1003.2.8.4) Combustible material shall not be stored in exits or exit enclosures. (UFC 1103.3.2.3) 3. Maintain sprinkler coverage per N.F.P.A. 13. Addition /relocation of walls, closets or partitions may Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206-575-4404 • Fax: 206 -575 -4439 Y` City of Tukwila Steven M. Mullet, Mayor Fire Department Thomas R Keefe, Fire Chief Page number 2 require relocating and /or adding sprinkler heads. All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1901) Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinances #1900 and #1901) 4. All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 5. Required fire resistive construction, including occupancy separations, area separation walls, exterior walls due to location on property, fire resistive requirements based on type of construction, draft stop partitions and roof coverings shall be maintained as specified in the Building Code and Fire Code and shall be properly repaired, restored or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (UFC 1111.1) 6. In order to provide you with the fastest police and fire protection under emergency conditions, please post your suite, room or apartment number in a conspicuous place near the main entry door. (UFC 901.4.4) This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206.575 -4404 • Fax: 206 -575 -4439 � w O O coo (ow w w 0 u. co d ' Z 0 Z Hi U CI o Ili , IL I iii Z '; , N. 0 City of Tukwila Fire Department Thomas P. Keefe, Fire Chief Page number 3 Any overlooked hazardous condition and /or violation of the adopted Fire or. Building Codes does not imply approval of such condition or violation. Yours truly, The Tukwila Fire Prevention Bureau cc: TFD file ncd Steven M. Mullet, Mayor Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206 - 575.4404 • Fax: 206 -575 -4439 FROM : GU INN MANAGEMENT CORPOP'',0 FAX : '" " • EMPLOYER:" is yciur' of industrial:insurance coverage. It remains active until your accouni iS ciosed. You are required •• • by law to post both this certificate and copies of the posters listed below, ,• • - ... You Will soon be of each 11 you require additional Insurance Scrviccs Division copies, call Labor and rtid ............ 360 Employer Services • • • Job Safety andilealth.Protection (available in Spanish) • e Your Rights as a Worker/Family Care Department of Labpr & Industries PO Box 44144 • Notice to Employees Olympia WA 98504 WORKER: The employer narried•below is an insured policyholL'z... with the Washington StateIndustriatinsurance Trust Fund. UB1*: 662„ 03,1 . 16s alic,LEffectpace Lctin 0 5/15/00. .;WTNIN1 mANAazmetqr coRPortAT lam Empl '31'H • NW • ... • • • . SEATTLL WA: 98177 WINN MANAGEMENT CORPORATION 1".,0 .80>!:. .77.624 SEATTLE 9177 I I 1 'if Your :Unified 1)usiric..37,dorOper i.s the . orily nu rr t ber• ' p . ti4e . ck'*.l . lett.atiivitkctinfOtitiilitra with. the Washingtomstate -ReA;entia.Litiiiiinitkitql . .'gP#Y. 1 ..., zs ,:•, . ,,,- V.4.•.• , f• :,.:.: '11%lia ur k itiiim . A5;4511 '1..t:° .11 - 114iii01 . 74 itLoi ■,4 .attrip . ... ti. '''" , e .. Y.--0. C• :- departrperirs • i _ Ar4.. Z.wsza; ■:::■:',',...w:•• . 7 • • ;:' 4.,''-' '•' 'r• ' • ..: ;%: -• : • • 1. •,,,,••••••••;.. . , /..4.zr, .1 • •• •• •- ... , ••• Oct. 21 200n • '1";Al V 4 10-20-00 07:58 TO:R J HALLISSEY Detach And Display Certificate FROM: • yam" RDIOVE 0 EXISTING HUNG 8' FLOUf2ECB4T I I( •TU4'.+ • LA EXISTING TRACT LIGHT BUILDNG CODE INFO: BLDG. CODE : U3CST BLDG. TYPE V- NSPRINCLERED TENANT AREA : 3522 SR FT. (3226 SR FT. FOR OFFICE SPACE, 5S6 SR FT. FOR WAREHOUSE SPACE) =PANT LOAD : 32 OFFICE + I WAREHOUSE IJ(XN2!C4✓FT IA F: (1 FVFR HANOI FAL4FF 3/A -2 DOORS I, 2, 3, 4 4: 3' x 8' SOLID CORE WOOD DOOR WV METAL JAM, I- 12• PAIR BUTTS, 3 SILENCERS, LATCHSET, WALL STOP DOOR E: A) ..?O -dp BUSTING DOORS NO WORK TYPICAL WALL FRAMING ATTACH BOTTOM TRACK T FLOOR UV POWDER DRIVEN ANCHORS AT 24 2 12' FIBBER BASE • OCONC. i r - 1111111111Millir CAULK GYP. BD. TO FLOOR • ALL SAND AND NSU_ WALLS 0 SUA ,T9,SLAB ROOM FNISH SCHEDULE: 1 FLOOR WALLS BASE CEILING 5 FLOOR WALLS BASE CEILING 6 FLOOR WALLS BASE CEILING RANSOM 5/8' GYP. BD. (TYPE 'X' • FIRE RATED WALLS) ACOUSTICAL BLANKET • WIND MALL, CONC. SLAB ON GRADE 30' REFLECTIVE CEILING PLAN Scale: I/8 ".I' -0" GATEWAY CORPORATE CENTER BU1LDSG 5 NSTR CARPET POINTED GYP. ED. RIBBER : EASING 5415P_ ACOUSTICAL, CLEAN AND REPAIR DAMAGED GRID AND REPLACE DAMAGED TILES, NSTALL NEW GRID 1 ALIGN W/ EXISTNG 2, 3, 14 ROOK :NEW CARPET 11.14LL5 : PANNED GYP. BD. BASE RBBER CEILING : EXISTNS SILSP. ACOUSTICAL, CLEAN AND REPAIR DAMAGED GRID MID REPLACE DAMAGED TILES 21' : NEW VCT (ARMSTRONG 51559) : PASTED GYP. BD. NEW SUSPENDED ACOUSTICAL NEW SHEET VINYL PAINTED : NEE COVED SHEET AIM PANTED 01(15114* N OI ` L USE N SEISMIC AREA AS REQU BY CODE 2. SUPPORTING M.5 TO BES GA. •4' -0• O/C CONECTED TO BOTTOM CHORD OF TRUSS W/ 1 54' EYE SCRfUS. EMBED I" MN. 0' 10' O VI ACING 1 15' EMMEN SCALE I/8" . I' -0" 25' RELRE4050(LS ® 31e. x 411. RELRE, 1/4• SAFETY GLASS N FETAL FRAM, SILL • 3' AFF. ENERGY CODES NOTE&. U NO CHANGE TO EXISTING BUILDBYs ENVELOPE 2) LIGHTS* DEMI - LESS EEN 5054 OF FDRUPES ARE NEW AND NSTALLED WATTAGE IS NOT BEND NCFSASED FUR¢ OUT EXISTING OIL DOOR WY 5/8• GYP. BD. OVER 3 -1/2' STEEL STUDS •24. -11 BAIT INSULATION - 3 TALL 4 12 GAVERTICAL UATE CONNECTED TO MAN RIMER 8 TO STRUCTURE ABOVE INSTALL A SECTION OF RIGID STEEL CONDUIT WVVERRCAL WARE R}NNG TAR) CENTER CF PIPE PIPE TO RUN FROM TOP OF TEE TO 50T!0M OF STRUCTURE ABOVE WRAP ETD CF VERTICAL- UARE AROUND PIPE BOTTOM. SEE ATTA SED TABLE FOR PIPE SIZE. TALL 12 GA WIRE CROSS BRACNG S EA. PLANE CF MAIN RIMER • 12 0/C • 45 ANGLE s"4 BOTH DIRECTIONS WRNS MT PONT WI 454 6'-0• FROM EA. WALL MOST CF THE ABOVE 16 TYPICALLY STOCKED N 10' uswne. COUPLMGS ARE AVAILABLE USERS NECESSARY. VALUES ARE BASED UPON STANDARD CALCULATIONS AND CAN BE SUBSTANTIATED BY AND MNEER4G FIRM. TABLE FOR PIPE 542543 4 . - EMT CONDUIT- ACCEPTANCE TO 4'-0' s4' - EMT CONDUIT- ACCEPTANCE TO 5' -2• I' - EMT CONDUIT - ACCEPTANCE TO 6' -0 IV; - EMT CONDUIT- ACCEPTANCE TO 8' -2' I54 - EMT CONDUIT- ACCEPTANCE TO 5' -b' NV- EMT CONDUIT - ACCEPTANCE TO I6' -6• 3' - EMT CONDUIT- ACCEPTANCE TO 20-2' 4• 5415 CONDUIT- ACCEPTA4CE TO 26' -0' 30 LEG43D: WRNS BALL TO 505(414 54 TIPO TO BE REMOVED = MI METAL STIR AI4t.L AT 24.0* 9' HEIGHT AS REQUIRED TO BOTTU4 CF WOO CEL/Yr5B• GYRED. CH EACH SIDE . 4 .. FED 6• METAL STD WALL AT 24.00HER 5B• GYP. BD. ON EACH SIDE TO STRICTURAL CEILtrx/RDOF (ML4T01 D:1515 3) N1BU D00R BUSING DOOR 1-•(. I' x 5' 549514* 2 -111BE AJ75L'8(F AO WAITS) 121 2' x 4' 0X151543 3-1IEE FLUORESCENT /88 WATTS) © 2' x 4' EOSINS, 3-1UBE RJIOFe00U TO BE RELOCATED (85 WATTS) ® 2 x 4'1413U OR RELOCATED 3 -TUBE FLLGREECENT (88 WATTS) t - 00.5514* RSSTROCM LIGHT ILLIt1N4TED BUT 5K34 54 DUPLEX OUTLET E50 * FCURFtEX CUTLET QE@ A WALL TELEPHONE CUTLET 52DRNG, CGTDUF, AND PILL STIN3 ONLY $ ELECTRIC MCA 0 25 CENTER NBU 7 , 0 , 4 CAI ISOSTP6 0' R —0 10' rJ 1 1 I I An Amax 1 PERMIT NO 9 THIS SET OF APPROVED PLANS MUST BE ON THE JOB AT ALL :MS DURING CONSTRUCTION. THIS BUILDING IS NOT TO BE OCCUPIED UNTIL AFTER FINAL i4USPECTION APPROVAL BY THE TUKWILA BUILDING DIVISION DEPARTMENT OF COMMUNITY DEVELOPMENT 15' 25' SCALE 1/8" ., ( -0" GATEWAY CORPORATE CENTER: BUILDNG 8 35' DEMOLISH WRING WALLS AND DOORS 30' 52. EL_ 00 EEh10 PLAN Im 1/8 "•I'-0' REVISIONS t;0 CHANGES SHALL BE MADE TO SCCF OF WORK WITHOUT PRIOFI OF TUKWILA BUILDING DI• 00 21' (;II( OF f AWI A • OVER \:J GATEWAY CORPORATE CENTER BUILDING 8 00 1 Da000-o 10/03/00 2:26 pm C: \CAD \8704 -8 \FIRESIDE \T -1 r. co co 88 vv W X = ate 0 7 V1 �' I/ 000o „ W II m 1.1 I li --- -I —ea 67ml■ !•, IIUU _ IIIII - - Nmalwomminammit - -m— 1 - 1 1 u M ' _1 Imo• E g I li via 11 a I ■om-I .. MI I �,al� �in... /1-i,■rim offi i I v iE P 1 — — ...............,„ - 1 v pr mwm.....■mmr yam" RDIOVE 0 EXISTING HUNG 8' FLOUf2ECB4T I I( •TU4'.+ • LA EXISTING TRACT LIGHT BUILDNG CODE INFO: BLDG. CODE : U3CST BLDG. TYPE V- NSPRINCLERED TENANT AREA : 3522 SR FT. (3226 SR FT. FOR OFFICE SPACE, 5S6 SR FT. FOR WAREHOUSE SPACE) =PANT LOAD : 32 OFFICE + I WAREHOUSE IJ(XN2!C4✓FT IA F: (1 FVFR HANOI FAL4FF 3/A -2 DOORS I, 2, 3, 4 4: 3' x 8' SOLID CORE WOOD DOOR WV METAL JAM, I- 12• PAIR BUTTS, 3 SILENCERS, LATCHSET, WALL STOP DOOR E: A) ..?O -dp BUSTING DOORS NO WORK TYPICAL WALL FRAMING ATTACH BOTTOM TRACK T FLOOR UV POWDER DRIVEN ANCHORS AT 24 2 12' FIBBER BASE • OCONC. i r - 1111111111Millir CAULK GYP. BD. TO FLOOR • ALL SAND AND NSU_ WALLS 0 SUA ,T9,SLAB ROOM FNISH SCHEDULE: 1 FLOOR WALLS BASE CEILING 5 FLOOR WALLS BASE CEILING 6 FLOOR WALLS BASE CEILING RANSOM 5/8' GYP. BD. (TYPE 'X' • FIRE RATED WALLS) ACOUSTICAL BLANKET • WIND MALL, CONC. SLAB ON GRADE 30' REFLECTIVE CEILING PLAN Scale: I/8 ".I' -0" GATEWAY CORPORATE CENTER BU1LDSG 5 NSTR CARPET POINTED GYP. ED. RIBBER : EASING 5415P_ ACOUSTICAL, CLEAN AND REPAIR DAMAGED GRID AND REPLACE DAMAGED TILES, NSTALL NEW GRID 1 ALIGN W/ EXISTNG 2, 3, 14 ROOK :NEW CARPET 11.14LL5 : PANNED GYP. BD. BASE RBBER CEILING : EXISTNS SILSP. ACOUSTICAL, CLEAN AND REPAIR DAMAGED GRID MID REPLACE DAMAGED TILES 21' : NEW VCT (ARMSTRONG 51559) : PASTED GYP. BD. NEW SUSPENDED ACOUSTICAL NEW SHEET VINYL PAINTED : NEE COVED SHEET AIM PANTED 01(15114* N OI ` L USE N SEISMIC AREA AS REQU BY CODE 2. SUPPORTING M.5 TO BES GA. •4' -0• O/C CONECTED TO BOTTOM CHORD OF TRUSS W/ 1 54' EYE SCRfUS. EMBED I" MN. 0' 10' O VI ACING 1 15' EMMEN SCALE I/8" . I' -0" 25' RELRE4050(LS ® 31e. x 411. RELRE, 1/4• SAFETY GLASS N FETAL FRAM, SILL • 3' AFF. ENERGY CODES NOTE&. U NO CHANGE TO EXISTING BUILDBYs ENVELOPE 2) LIGHTS* DEMI - LESS EEN 5054 OF FDRUPES ARE NEW AND NSTALLED WATTAGE IS NOT BEND NCFSASED FUR¢ OUT EXISTING OIL DOOR WY 5/8• GYP. BD. OVER 3 -1/2' STEEL STUDS •24. -11 BAIT INSULATION - 3 TALL 4 12 GAVERTICAL UATE CONNECTED TO MAN RIMER 8 TO STRUCTURE ABOVE INSTALL A SECTION OF RIGID STEEL CONDUIT WVVERRCAL WARE R}NNG TAR) CENTER CF PIPE PIPE TO RUN FROM TOP OF TEE TO 50T!0M OF STRUCTURE ABOVE WRAP ETD CF VERTICAL- UARE AROUND PIPE BOTTOM. SEE ATTA SED TABLE FOR PIPE SIZE. TALL 12 GA WIRE CROSS BRACNG S EA. PLANE CF MAIN RIMER • 12 0/C • 45 ANGLE s"4 BOTH DIRECTIONS WRNS MT PONT WI 454 6'-0• FROM EA. WALL MOST CF THE ABOVE 16 TYPICALLY STOCKED N 10' uswne. COUPLMGS ARE AVAILABLE USERS NECESSARY. VALUES ARE BASED UPON STANDARD CALCULATIONS AND CAN BE SUBSTANTIATED BY AND MNEER4G FIRM. TABLE FOR PIPE 542543 4 . - EMT CONDUIT- ACCEPTANCE TO 4'-0' s4' - EMT CONDUIT- ACCEPTANCE TO 5' -2• I' - EMT CONDUIT - ACCEPTANCE TO 6' -0 IV; - EMT CONDUIT- ACCEPTANCE TO 8' -2' I54 - EMT CONDUIT- ACCEPTANCE TO 5' -b' NV- EMT CONDUIT - ACCEPTANCE TO I6' -6• 3' - EMT CONDUIT- ACCEPTANCE TO 20-2' 4• 5415 CONDUIT- ACCEPTA4CE TO 26' -0' 30 LEG43D: WRNS BALL TO 505(414 54 TIPO TO BE REMOVED = MI METAL STIR AI4t.L AT 24.0* 9' HEIGHT AS REQUIRED TO BOTTU4 CF WOO CEL/Yr5B• GYRED. CH EACH SIDE . 4 .. FED 6• METAL STD WALL AT 24.00HER 5B• GYP. BD. ON EACH SIDE TO STRICTURAL CEILtrx/RDOF (ML4T01 D:1515 3) N1BU D00R BUSING DOOR 1-•(. I' x 5' 549514* 2 -111BE AJ75L'8(F AO WAITS) 121 2' x 4' 0X151543 3-1IEE FLUORESCENT /88 WATTS) © 2' x 4' EOSINS, 3-1UBE RJIOFe00U TO BE RELOCATED (85 WATTS) ® 2 x 4'1413U OR RELOCATED 3 -TUBE FLLGREECENT (88 WATTS) t - 00.5514* RSSTROCM LIGHT ILLIt1N4TED BUT 5K34 54 DUPLEX OUTLET E50 * FCURFtEX CUTLET QE@ A WALL TELEPHONE CUTLET 52DRNG, CGTDUF, AND PILL STIN3 ONLY $ ELECTRIC MCA 0 25 CENTER NBU 7 , 0 , 4 CAI ISOSTP6 0' R —0 10' rJ 1 1 I I An Amax 1 PERMIT NO 9 THIS SET OF APPROVED PLANS MUST BE ON THE JOB AT ALL :MS DURING CONSTRUCTION. THIS BUILDING IS NOT TO BE OCCUPIED UNTIL AFTER FINAL i4USPECTION APPROVAL BY THE TUKWILA BUILDING DIVISION DEPARTMENT OF COMMUNITY DEVELOPMENT 15' 25' SCALE 1/8" ., ( -0" GATEWAY CORPORATE CENTER: BUILDNG 8 35' DEMOLISH WRING WALLS AND DOORS 30' 52. EL_ 00 EEh10 PLAN Im 1/8 "•I'-0' REVISIONS t;0 CHANGES SHALL BE MADE TO SCCF OF WORK WITHOUT PRIOFI OF TUKWILA BUILDING DI• 00 21' (;II( OF f AWI A • OVER \:J GATEWAY CORPORATE CENTER BUILDING 8 00 1 Da000-o 10/03/00 2:26 pm C: \CAD \8704 -8 \FIRESIDE \T -1 r. co co 88 vv W X = ate 0 7 V1