Loading...
HomeMy WebLinkAboutPermit D2000-382 - LANDSBERG - OFFICES0 KENT H. LANDSBERG 5835 SEGALE PK DR &ACV' D2000-382 City of Tukwila Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Parcel No: Address: Suite No: Location: Category: Type: Zoning: Const Type: Gas /Elec.: Units: Setbacks:_ Water: Wetlands: WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES. APPLICANT IS PROCEEDING AT THEIR OWN RISK. 352304 -9018 5835 SEGALE PARK DR C AOFF DEVPERM 001 North: HIGHLINE . DEVELOPMENT PERMIT 0 South: .0 Sewer: SEPTIC Slopes: N Contractor License No:. LAPIAL *008J8 OCCUPANT OWNER CONTACT CONTRACTOR Signature: Print Name:__i2Jc_ KENT H. LANDSBERG CO 5835 SEGALE PARK DR C, TUKWILA, WA 98188 LA PIANTA LTD PARTNERSHIP PO BOX 88050, TUKWILA WA 98138 STEVE NELSON PO BOX 88028, TUKWILA WA 98138 LA PIANTA LLC Permit Center Authorized Signature: Loc. This permit shall become null and void 180 days from the date of issuance, or for a period of 180 days from the last Permit No: Status: Issued: Expires: Occupancy: UBC: Fire Protection: East: .0 West: Streams: Phone: Phone: Phone: Phone: D2000 -382 ISSUED 12/07/2000 06/05/2001 Date: _ .?I749 0 (206) 431 -3670 OFFICE 1997 SPRINKLERED .0 (206) 575 -3200 206 - 575 -2558 206 - 575 -7000 PO BOX 88028,_TUKWILA WA 98138 ***************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Description: NEW TENANT OFFICES. ****************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * Construction Valuation: $ 120,138.00 PUBLIC WORKS PERMITS: *(Water Meter Permits Listed Separate) Eng. Appr: ? . Curb Cut /Access /Sidewalk /CSS: N Fire Loop Hydrant: N No: Size(in) .00 Flood. Control Zone: N Hauling: N Start Time: End Time: Land Altering: N Cut: Fill: - Landscape Irrigation: N _ Moving Oversized Load: N Start Time: End Time: Sanitary Side Sewer: N . No: Sewer Main Extension: N Private: N Public: N Storm Drainage: N Street Use: N Water Main Extension: N Private: N Public: N ****************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *, TOTAL DEVELOPMENT PERMIT FEES: $ 1,838.23 ****************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * **' QLate: _ L2.-7 - 00 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this development permit. if the work is not commenced within if the work is suspended or abandoned inspection. • z re ug n 0 w J � LL; w 0 ILQ d = uY zo uj O N o wuj '0 IL O w z :. 0 N: F. O z C1T•Y OF 1 UKWILH Address: 5835 SEGALE PARK DR C Suite: Tenant: Type: DEVPERM Parcel #: 352304-9018 Permit No: 02000 -382 ISSUED 11/29/2000 Issued: 12/07/2000 Status: Applied: k**- k** k*** k*****• k*** k* k*** kk****' k* *k *•k* * * **•k * * *kk'kkk'k *•k * ** * Permit Conditions: 1. 'No changes wi11 be made to the plans unless approved by the Engineer and the Tukwila Building Division. . Any new ceiling grid, and light fixture installation is required to meet .:lateral bracing requirements for Seismic Zone 3. . :Partition walls .attached to ceiling grid must be laterally ,braced if over eight (8) feet in length. Any exposed insulations backing material shall have ``a Flame ''Spread Rating of 25 `or less, and material shall bear ' i dent i 'fication ;showing "t'he fire performance rating thereof. • All construction to be done in conforrnance with approved plans and, requirements of the Uniform Building Code (1997 Edi as amended, Uniform: Mechanical Code (1997 Edition andPWashington State Energy :Code (1997 Edition). • Plumbing permits shall be obtained through the Seattle -Kin.. c county Department of Public ;Health. Plumbing will be ,inspected by' that .,agency, including° all gas piping (2'96 -4722) Val j - i d i ty. "..of Permit; The . issuance of , a permit or approval o plans, specif.icattons. and tati compuons .shall not be con.- strue to; be 'a permit for, `or . anr approval . of , any violation of .any of the, pr ov i si ons.of the buii d i:ng: code or of any other.. ordinance of the j urisdiction. No ,permit. presuming't :give `auth'or ity:, to ;violate or cancel the provisions of - ., this code =` ahal;l:° be valid. • A11 rack°::storage requires a separate permit' through the City` of Tukw,i la. Structural calculations .staniped`.by a Washington ;State 1i.cense,d Structural Engineer are required for rack: storage over eight -(8) feet in height. Electr ical permits shall be obtained through the; Washington State Div:ision' "of ,Labor and Industries' and all electrical work will be ° by that agency (248-6630). 1 0 . ` There shall " be�'no .occupancy of ; the b u i l d i n g ( s ) until ` the final inspection has been completed bv the Tukwila Building Inspector. . All permits, inspection records, ,and approved plans shall be available at the job site prior to the start of any con - struction. These documents are to be maintained and avail - able until final inspection approval is granted. 12. ** *FIRE DEPARTMENT CONDITIONS * ** 13. The attached set of plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 14. 'The total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 3000 sq. ft. of area. The extinguishers) should be of the "All Purpose" (2A, 10B:C) dry chemical type. Travel r ,...n,. Z.a31.0.54 H >a i1 * :awry. 404 /1a1WCANVIM •inatteOSAalifalifi""a • z 0 N 0 w w ; J' w 0 ; g-J I- _ Z w U N 0 H: = V ' • ui z O ~' z distance to any fire extinguisher must be 75' or less. (NFPA 10. 3 -1.1) 15. Portable fire extinguishers shall be securely installed on the hanger or in the bracket supplied, placed in cabinets or wall recesses. The hanger or bracket shall be securely and properly anchored to the mounting surface in accordance with the manufacturer's instructions. The extinguisher shall be installed so that the top of the extinguisher is not more than 5 feet above the floor and the clearance between the bottom of the extinguisher and the floor shall not be less than 4 inches. Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be identified with a sign stating, "Fire Extinguisher with an arrow pointing to the unit. (NFPA 10, 106.3) (UFC Standard 10 -1) Ciear access to fire extinquishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1-6,5) 18. Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month 'and year that the inspection was Performed and shall identify. the ,company or. person performing the ;(NFPA 10, 43, 4 -4 and 4 -4.3) Every; -six:; Years, .dry chemical and halon type fire extinguishers shall be emptied and subjected to the applicable recharge procedures.' (NFPA 10, 4 -4.1) If' the required monthly and yearly:` inspections of the fire extinguishe'r(s) are not accomplished or the inspection tag s not complete, a reputable fire extinguisher service company will be required to conduct ' ;these required surveys. (NFPA 10,' 4-3, 4-4) Maintain fire extinguisher coverage throughout. Norpoint in an unsprinklered building may be more than 200 feet; From`an :exit,` along the path of travel. ' (UBC 1004:2.5:2.1) 21. No 'pdint . -in a° building may be more than 250 :feet ; from an exit, measured along the path of travel. (UBC '. 1004. 2. Exit � ;`doors,: shall '`swing in the direction of exit travel when any hazardous area or when serving an occupant load of 50 or more. ;~ ,(UBC , 1003.3.1.5) Exit doors,shall be openable from the inside without the of a key or any special knowledge or effort. Exit doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved - type. (UFC 1207.3) Dead bolts are not allowed on "auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (UFC 1207.3) 25. When two or more exits from a story are required, exit signs shall be installed at the required exits and where otherwise necessary to clearly indicate the direction of egress. (UBC 1003.2.8.2) 26. When two or more exits from a story are required and when two or more exits from a room or an area are required, exit signs shall be illuminated. (UBC 1003.2.8.4) 27. Internally illuminated exit signs shall have both bulbs working at all times. (UBC 1003.2.8.4) ,.449. OW. .4.,,.. ;... w ; _i O C3 0 0 ; J H w 0 u Q ; N d I— al H 0 z f UJ 0 0 , O N Ca w w ' r- V w z F ` 28. .Exits shall be i l lum any time the bui ldinq_Js occupied with light, wing an intensity of not ' ;s than 1 foot candle at floor level. Fixtures required tor exit illumination shall be supplied from separate sources of power for Group_ I, Division 1.1 and 1.2 occupancies and for all other occupancies where the exiting system serves an occupant_ load of 100 or more. (UBC 1003.2.9, 1003.2.9.2) 29. The power supply for means of egress illumination shall normally be provided by the premises' electrical supply. In the event of it's failure, illumination shall be automatically provided from an emergency system for Group I, Divisions 1.1. and 1.2 occupancies and for all other occupancies where the means of egress system serves an .occupant load of 100 or more. Such emergency systems shall be installed in accordance with the electrical code. (UBC 1003.9.2) All exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than <1 1/2 hour's; " i , n case of :primary power loss, the exit signs shall 'a so, be connected to an emergency electrical 'system provided from 'storage batteries, unit - equipment or an on site':`'gener,ator set,' and the system shall be installed in accordance ; with" the,electrical.; code. (UBC 1003.2.8.5) . Maintiann'.spr.inkler. coverage ; per`'N,.F.P.A. 13. Addition /relocation of walls, closets or partitions may require relocating and /or adding sprinkler heads. 32. 5prinkier_ p shall be extended to all areas where requi;red, including all enclosed areas, below obstructions. and-Under .:; overhangs greater' than four feet wide. (NFPA r All ' new sprinkler and all modifications to existing sprinkler :?systems shall have fire department review and ipprovai of drawings prior `to instal'lation or modification. New sprinkler systems and all nodi'fications to sprinkler systems involving." more +`than 50 heads, shall have the written approval .of the W.S P.B. , Factory Mutual, ,Industrial Risk Insurers, Kefinper or any other representative designated and /or recargni'zed by the City of Tukwila, Prior to submittal . ; to' the Tukwila F i r e Prevention ' Bureau. " No sprinkler work shall commence without approved drawings. ,(City Ordinance #1901) 34. All sprinkler system plans, calculations and the contractors Materials and Test Certificates submitted to the Tukwila` Fire` Prevention Bureau must be stamped with the appropriate level of competency seal. (WAC 212 -80) Maintain automatic fire detector, coverage per N.F.P.A. 72. Addition /relocation of walls, closets or partitions may require relocating and /or adding automatic fire detectors 36. :Maintain square foot coverage of detectors per manufacturer's specifications in all areas including: closets, elevator shafts, top of stairwells, etc. (NFPA 72, 5- 1.4.2) 37. All new fire alarm systems or modifications to existing systems shall have the written approval of the Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1900) (UFC 1001.3) All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 39. An aisle to and working space shall be provided for each w. VO :. co 0 W I J w O g:3 Z I- O Z H! Dp O u 0 r w W V O i ri i z'. w z electrical panel . An aisle width not less than 24 inches shall provide access to the panel and 30 inches of working space shall be provided directly in front of the panel. (NEC 110-16(a), NEC 110-16(c)) 40. Each circuit breaker shall be legibly marked to indicate it's purpose. (NEC 110-22) 4 1. Required f ire resistive construction, including occupancy separations, area separation walls. exterior walls due to location on property, f ire resistive requirements based on type of construction. draft stop partitions and roof coverings shall be maintained as specified in the Bui I ding Code and Fire Code and shall be properly repaired, restored or replaced when damaged, altered, breached, penetrated, removed or improperly instal led. (UFC 1111.1) 42. The maximum flame spread class of finish materials used on interior wal 1 s and cei 1 ings shall not exceed that set forth in Table No. 8-B of ,the Uniform Building Code. (UBC 804.1) 3. • Your street address must be conspicuously posted on the building and shall be plainly visible and legible From the street. Numbers shall contrast with their ,background. (UFC 901.4.4) • - , 44. In order 'to provide you, with the fastest police and fire g5 u..< protection under emergency conditions, please post your 0 3 .suite room or apartment number in a conspicuous place near z the main entry door. (UFC 901.4.4) ' i-ILI ,., .. g 45 - Fire:(0ePartment lock boxes shall be provided for access to 0 ; all ,'fire,ilarm panels and sprinkler risers. The *,aPPOPriate keY(s), for access shall be placed in the :E D lokbox. Lockbox 'order forms must be , obtained from the .Tukwila Fire Department. (City Ordinance #1900) . 46. Contact the Tukwila ,.F ire Prevention Bureau to witness all regbired . inspections and tests. (UFC 10.503) (City 111 u j Ordinance #1900 and #1901) 47 . 'Tills review limited to ‘speculative tenant, space only - !o -0 , special f ire 'permits may , be necessary . depending on , detailed °- ta descriptton' of intended use. , 48 . AnV'overlooked hazardous condition and/or violation of the , 0 ad Fire or Building Codes does not imply approval of , Z such condition or ,violation. 49. The pjans were reviewed by _512._. If you have any „ 'questions, please 'call the Tukwila Fire Prevention Bureau, at ( 20 6) 575-4407 . I hereby certifY:,that 1 have read these conditions and 01* comply with them' as outlined. All provisions of law and ordinances governing this work wiul b -Oompl ied with,. whether specif ed herein or not. The granting of this permit .does not 'presume to give authority to violate or cancel the provisions of any other work or local laws regulating construction or the 'PerforMance of work. Print Name: i kqnra-, l Date: Z 1— ce ?). 0 co o w 0 PROPERTY OWNER: L - h 1_LC Phone No: ( ) 575-... z oD d Address: Q G x 86 0� tee �T"-r t (c y % la '- .9 COITRACK02: La Phone No: (X06 ) S'7S— 2000 Address : pO Gox 880.99- Ci atate/ IG tr 5913 WA State Contractor's License No.: LApipiLlt 00t358 Expiration Date: y/ / / 0 ( / ARCHITECT: La v, e h � -►c.I1 ev. .1. t of woes Phone No: ( ) 204 325- 2553 Address: /3a 1. S.keexck .-t i t Z50 C'ty Cea /St c Zip: 444 Sir Zz WA State Architect's License No.: 269s �o� ���� �otxaU Expiration Date: /., / / `� / o CITY OIJKWILA Department of Community Development Building Division- Permit Center 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431 -3670 Blanket Permit Tenant Improvement Application ALL APPLICATIONS MUST BE FILLED OUT COMPLETELY (Shaded area for Office Use Only) PLAN REVIEW NUMBER BLANKET PERMIT AGREEMENT NO: DESCRIPTION Building Surcharge AMOUNT RCPT # DATE 4.50 Building Permit Fee Plan Check Fee II -21-co Total Site Address: A1R3 ' k & le Pct... 'Q uC 1 C Value of Construction: $ 2aD /35' Floor: / = Suite Number: Assessor Account No.: 35:V,30 5 O I I C iJ. /7 La.octsbNe Co. Project /Tenant Name: Type of Work: Tenant Improvement ❑ Interior Demolition ❑ Other: Describe work to be done: A>e u , �e►.i 4 in 1- o- Qt ce. Building Type: 222' -1V Building Use (office, warehouse, etc): tADp—.e C.k-( Se Nature of Occupancy (printing, manufacturing, etc): P4c c149 n5 R- m44c,6 Square Footage: Entire Building: 312, 205 Construction Area: ..7.5/ 4 Tenant Space: /�7 73 Will there be a change in use? xi No ❑ Yes If "yes ", explain: Will there be rack storage? 14 No ❑ Yes Existing Fire Protection: ( Sprinklers ( Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? gi No ❑ Yes If "yes ", please explain: Will there be ANY structural work? ( No ❑ Yes If "yes ", please describe: Signature: - 9 0k"") Print Name: e lC K..) ,N els Address: n Sec) p Organization: I ? LfSI ✓)CSS Q '5c4, lc Phone No: z 06 5 '55S City/State/Zip 71_4- c. c lc, 4 '‘f /3F 1 hereby certifi that 1 have read and examined this application and know the same to be true and correct, and 1 am authorized under Blanket Permit Agreement No. 55 -C G94 to apply for and obtain this permit. See reverse side of application for specific plan submittal requirements and information. Date application accepted: I -2A-0 Date application expires: ! 'zei n o 1 04/24/00 U U to o' W ca J t.... W 0 : gQ h Z I- I- 0 W ~ U � 0 - 0 t— WW Z i- 2 . 11 Z 0 z "X" REQUIRED INSPECTIONS DATE APPROVED INSPECT INITIALS PLANS DATE Y DATE(S) CORRECTION NOTICE ISSUED x 1. Framing )( 2. Insulation X 3. Suspended Ceiling X 4. Wallboard Fastening DO NOT PROCEED BEYOND THIS POINT UNTIL THE BUILDING PERMIT IS ISSUED. PERMIT MUST BE PICKED UP WITHIN 24 HOURS OF NOTIFICATION THAT THE PERMIT IS READY. Blanket Permit Agreement Tenant Improvement Temporary Inspection Card Plan PI R No.: Dz se Date Issued: 1 1-2q -a34 Blanket Permit Agreement No.: 55. Doi- i v A Project Name /Job No.: / 1) I. Q_+TCl/s�.� q Site Address: 5-s �- sc5 alc 01-1 v-r It It CALL FOR INSPECTIONS AT LEAST 24 HOURS IN ADVANCE (431 -3670) (Have Plan Review number, Blanket Permit Agreement number pro name and site address read ) INSPECTIONS 1. FRAMING - After rough -in inspections such as mechanical, plumbing, gas piping, electrical and fire stopping is in place. 2. INSULATION - After framing approval, but before insulation of wallboard. Baffles must be installed to keep attic ventilation points clear. 3. SUSPENDED CEILING - Fasten diffusers, lights and seismic bracing. 4. WALLBOARD FASTENING - Prior to taping (See UBC Chap. 25 and Table 25G). 5. PLAN CHECK INSPECTION - Immediately after the Tenant Improvement Permit is picked -up by the applicant. Work may not proceed until the City Inspector delivers the plans and new inspection card to the site. This inspection should be scheduled at the Permit Center when the permit is obtained. • Construction will not proceed past required inspections. • The Building Permit and approved plans shall be picked -up by the applicant within 24 hours of notification that the permit is ready. Failure to do so may result in a stop work order. • Construction may not deviate from that shown on the plans as submitted at time of application. • All corrections shall be made within three (3) days of notification by Building Inspector. • No more than 30 days shall elapse between the last required inspection and the "Building Final" • Unauthorized occupancy and /or use of the remodeled area shall not occur until the Building Inspector completes the "Building Final," which takes place after the Building Permit and Permanent Inspection Card has been issued. • The City reserves the right to stop work at any time that in its judgment the work presents a safety problem, warrants a building permit prior to continuing work, is not proceeding according to approved plans, or otherwise would not qualify for consideration under the blanket permit process. • The following.work is not covered under the blanket permit process. This work shall not start until approvals and permits are obtained through the applicable agencies, under their normal process: Electrical Department of Labor and Industries (248 -6630) Plumbing /Gas Piping King County Health Department (296 -4722) Fire Protection City of Tukwila Fire Department (575 -4404) Mechanical City of Tukwila Permit Center (431 -3670) Rack Storage City of Tukwila Permit Center (431 -3670) THIS IS A TEMPORARY INSPECTION CARD ONLY AND WILL BE REPLACED BY A PERMANENT INSPECTION CARD WHEN THE BUILDING PERMIT IS ISSUED. 11/01/99 Blanket Permit Inspection Card f p. a a.(~ *Ik.i 7 kN:Nr1L4 , 'C"dMW ,1Ni R?Wi W 7 't( t • • R±14 •4t+1 .- 4, ^N4,Vfi%W. CITY OFUKWILA Department of Community Development Building Division - Permit Center 6300 Southcenfer Boulevard, Tukwila, WA 98188 Telephone: (206) 431 -3670 CONTRACTOR/APPLICANT BEGINS WORK AT THEIR OWN RISK PER THE TERMS OF THE BLANKET PERMIT AGREEMENT. This tenant improvement application may be submitted for non - structural Interior construction which is authorized under an existing approved blanket permit agreement. It is the responsibility of the applicant to be aware and comply with all the terms and conditions as set forth in the agreement. The work Is limited to that shown on the plans as submitted with this application, and such work is limited to non- structural interior construction only. The following work is not covered under the blanket permit process and separate approvals, permits and inspections are obtained through the applicable agencies, ELECTRICAL - Department of Labor and Industries (248 -6630) PLUMBINGIGAS PIPING - King County Health Department (296 -4722) FIRE PROTECTION - City of Tukwila Fire Department (575 -4404) MECHANICAL - City of Tukwila Permit Center (431 -3670) RACK STORAGE - City of Tukwila Permit Center (431 -3670) BUILDING PERMIT APPLICATION Application Submittal - Application and plans must be complete in order to be accepted for plan review. Make sure to fill out the application completely and follow the plans submittal checklist which follows. Handouts are available at the Permit Center which provide more in -depth detail on preparing the submittal. Authorized Agent - The applicant must be an authorized agent as identified In the Blanket Permit. Fees - The permit fees are based on valuation of construction as declared by the applicant on the application, and shall include all the work to be covered under the permit. The valuation will be reviewed and is subject to revision by the Building Official to insure compliance with current fee schedules. To obtain a fee schedule, contact the Permit Center at 431 -3670. SUBMITTAL CHECKLIST Completed Building Permit Application 11/01/99 Blanket Permit Agreement Information • GENERAL INFORMATION 1 lr Attachment #1 - Architects Statement Three (3) sets of construction drawings, which include: B Site Plan, showing: 0 Building location on property &Adjoining public rights -of -way C�Parking layout 0 of tenant space or area of work within building Overall dimensions of building COverall dimensions of tenant space, or area or work G Name of each common wall tenant(s) and type of business or occupancy E Floor plan of entire floor or tenant space that the work is taking place, showing: Tenant space layout with use of each room labeled Cpl All exit doors, corridors and egress patterns C'AII new walls, existing walls and proposed walls (provide construction key) O All other proposed construction Er-Construction details Cr Construction key G'-Cross sections showing wall construction and method of attachment, floor and ceiling CYReflected ceiling plan (if applicable) DMiscellaneous er 6" x 8" blank space provided on lower right hand corner of each page of plans (for use by the plan checker) C`r block on each sheet, identifying: • Project name • Company job number (if applicable) • Site address 1 Blanket permit agreement number • Architect, address and phone number Or Each sheet of plans stamped by a Washington State licensed architect 0 Minimum sheet size 18" x 24" (3 '� Plans must be drawn to scale and clearly dimensioned Drawings shall be prints which are clearly readable (original pencil or highlighted drawings are not acceptable.) Er Permit Fees (plan check fee, building permit fee and state building surcharge) Architect/Engineer Stamp: • sect; r�.,. :; • ..b' IL IP r.. "4 - . \�, -. Naa STATE OF M..tt'.. .. Architect /En r Signature: Print Name: Firm Name: G rt Cr H*- r ell u. •L 5 Business Phone: Zb6 325- 2564 Street Address: / So 1 - G.lCrIstcte ` +i II le ZSo City /State/Zip: 0, 14-I.e I.„ A q& /Z.2_ PLAN REVIEW NO.: PROJECT NAME/ TENANT: leevt it L a wets \e. co BLANKET PERMIT AGREEMENT NO,; • 9- 603_ IS PA . COMPANY JOB NO,: oU. q i- 03 SITE ADDRESS: 3835 SeT� le �} n P G..1c �+1.ivP C' ... —•- — —• NOV.22.2000 9:18AM LANCE MUELLER NO.873 P.2 /2 CITY OF TUKWILA Department of Community Development Building Division•Permlt Center 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431 -3670 Blanket Permit Agreement Tenant Improvement Application Attachment 1 - Architects Statement Is any part of the work proposed under this application include structural work of affect structural components of the building? O Yes 0 No If yes, has the structural work been authorized by the Tukwila Building Official to be included in this application? O Yes O No Does the proposed work comply with the requirements of Chapter 10 of the Uniform Building Code (1997 Edition)? As Yes O No If no, please explain: Will any special inspections be required per Chapter 17 of the Uniform Building Code (1997 Edition)? OYes No If yes, list specific Inspections: As a result of this proposal, does the parking meet the requirements of the Tukwila Zoning Code parking requirements? X) Yes O No If no, please explain deficiency: 03/22/00 alenket Permit Architect SI tt A 1 t,C.K* It* A:4•ttlA•* 4 A.A. A tt:1** b r kA.1 4*A.A AAA 4hA:l l'1-A •.4A J.1 V ' Of' 1 is f. P1 J, L lJ r i' ) 4 t. l l rt s A ...A.* 1* [ t l ► :,1 T: ►'i'A•kdc'v*..A;4A war*t4Ait*�,•k.A•t 1A:AA .4 r fi . , , . 1 rtl►rtttrt?r : ((9ts�rr��i t HPIi u , i t l • 3..� 1 1 a , ti ll L!.! .'a; !1 s1 J.' +.: ;is; t'icvvmw'ti t.. 11etilou t .. 111.:1: t. , NOtat 1011 P LC) Ll•: 1J 1.J s.t ! ii 1 t c .'t'1.8 l'(i. vs, t() c Isar ),, i)u) wt,{ 2. 1V.1tte: I)ht) 0t4 I)t• tiEL1)1.►11i (.t i'l.it111 f_. I'tir',Ce 1 , rla: ;I i2;1104 X04 to ti 7 I: ii a d r t si±3: 8,�;:' bl 1:?i41_V. f'01t1; i . t: 1rt�s~ Ir�t ± t'atai r•tsu<1 r. t1J1 : k3 • lrtl�ri 1.,..t l.,.'tf5 1•titicl ALL. Fiat : J.�t.5;: i.: ') 13 it1atl(.(: ` . Vl} •k is* it 4***+ kokt4' 4•*4***• kA,, it*** it k*• t• i t ***:l *tltlit **4•*d•*tt*+ * * A• . 'iv A ti ( ° a tl ll l';' t:a tt a it a tS (, r i Pt ion tirnatttat 0 0 G 3,2 1 j 0U. kSU!•1,1)1116 -- r:flr4ftk.til; 1... 1 1 1 a;: ():6'() :Al r , ,i :).o 4 '.' a 1 • H 11 f 131111_ t : , 1 f i a t► ft t';10lt t3 F' •l 41 ° 411:Mr1947717.4"`y1 r "#+!? ,p'pit J • +.,.. a...w.s ...!tx,, •,sra .,.�.w,.:,y...:wa:c�i.c z uw....., .N..,, „W ...:i. 44, sie CO IL Or 2 4 LL '. CO W • HO. 'Z w 2 j U D r co ! 0 �; = W H It:. 'lL Z• - • dr•is A*•'dd * *k Itsi * *• dk** + .*d, d 'I ** 1*d,o1.fi ili :t** • •ii,it 4 Y : x'irxd; .0. it i7'7+•r•:ticor,xl7% 71 a 7. ti a �^ "),../ 'tit �� f1 • I t *** 4 **7 **il'4e \* * 4147174 *44#141\ t::rris:4 i .- d; *** *At4 * *It,7 \tit*d,x l7i r.tkllr In I I 14 t1F1 ' ;I -fei:1).; '.1 19ric IA i't ` ! ,. ' !il t 1 r; o a / -.l;I' 1 . 1 r 1i 1 l' ci'. , Esertti nil ttI [7(1t 1 iIi:,C : i's ."Ic1{:Et{:10rtr: i:l::.11ttt.t:. It tJ'z, J. 0 a . .': i.Pt. ILit f' rtri1t::rici: ;1) 2 0 ( Q - -; ii. I h:LVI I) E. V EL I.% I't'Lr!t Nisttrt!'t i' <t 1^ t ) N t1 r. ,! : , . : . . . 3 0 , - 9 0 ± t 4 i e f4 cl ii i'''ti E,1 E,E t tiEl•'.} :.LGI:1tE: PkItI', tilt, rt °i: x t ' f.(:t?f ' .t{ a i' _';3 st '! �i � n7 eti t ::! :s . t c7 t << t t L l I. cif:. r, ? -` ! ..� r7 13'fi, t ctfir t: 1 .t ,..1 1 t ***{ r'h+4, * * *c * *:h•dr }al *, *ft *dr* .**** *k * *. * ** * * * * *4 * # *h *it ** ** * **A ** *i, { Jf i:Cft0il11, 1`!001? I)c ?!3[ +I 1 fl1 1 011 l[ r 14(0[1111'5 GG: 0/34a.fl;?u , I'LHra t: :HLCt; '• illirt(tEti '+,r!•Je.i 0282 12101 9710. TOTAL 722.38 i'itli ittTrivevr , .irt : h N , a ?Yt`i°rf9)EYt ',s s 3; 4 41,17.41.,„ ?'71,3 7 ; 41.; j j .�. • 41' re 2 D, U 0! U W H; C/) u- W 0, LL di W . Z � 2 a ; 2j . U col = r 1— U LL 0 '. U N' 0 �' Project: I -7., Type of Inspec ' n: Aa f 5 `AS SP yQ e k Date called: r 3- d..1 o f Special instructions: Date wanted: a.m. 3 - ' `0 1 p.m. Requester: Phone: INSPECTION NO: CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 9818 Approved per applicable codes. ~ i INSPECTION RECOII 1 3 8 Retain a cop with - ermit K 2 i66 41 0_ Y P PERMIT NO. (206)43 - 1.3670 Corrections required prior to approval. \, COMMENTS: C)V 4-0 \'‘vIctl Inspector: -p) n n "R ‘cme S tr Date: 3 2 2 0 f $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: ^ai Pr� � 1 Q ZA�� guS‘roS Ty of Inspec�n: ��J�c� l4ISy€(- t V " Date called: G Addressff 575-35" S e� Ie Q � r L O.r. Special instructions: C - %A6( Date anted: 2� Z $ , `7 a.m. p.m. RR ster: Phone: Z06-575 2.S INSPECTION RECD, D Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 ❑ Approved per applicable codes. Corrections required prior to approval. COMMENTS)) /l/2 7 6,07 . � f i -r/I/ �,J id c Gi/Y ih ./ 4411111111r •■•• d ,ar (,),• >4) 4 1 Inspector Date: $47.00 REINSPECTION REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt. No: Date: t , 4uu2,,443`6Art uitaa .ig a � .i s ai I ': t't't't 2000 - 3 ?2 PERMIT NO. (206)431 -360 Project: - (`G 0.5 L Type of Inspect on: 5iis pedvcv (i ck.0-64 v ' Address: 5 ? 3 5 3 67 r C Date (galled: :� //S /o / Special instructions: f\e -//.s i - "W, Date wanted: 0 / /0/0/ p.m. R u�ester: �//Y] Phone: .,:?-0 W 5''75 -�556' Approved per applicable codes. INSPECTION RECd Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 Corrections required prior to approval. COMMENTS: Inspector y :),u 0 /V2 Date: 2 - )1 -Q) $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid,:.,:, at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: cL J v t� O co a' to W, 9 LL uj Ei2 LL d! ? I a 2 I- UJ co D I- W ' H V i . Z U co: O ,1, z Project: a.LF Type of Inspection:. K /A /j�/rbarrtet►- .o )9 Date led: /13/101 Address 3S Cie Pt Dr Special instructions: t1 C Date wahte .0 a.m. p.m. R r: T Phone: - )Dlo -3 -..ZSS k INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 g pproved per applicable codes. INSPECTION REC D Retain a copy with permit PERMIT NO. (206)431 -3 COMMENTS: Corrections required prior to approval. Date _ O $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule rcinspection. Receipt No: Date: • :L .i�tisi.a. k1 u5 +Fa'+a��r..I..�.iM.W a.'ti,issxx ;. .e7ftn� g in W ': Woo 2 J U 0, 0 co W W ; 1 W 0 g co F .W . Z F.. I— 0 Z I—; W ? 2 U 0 ' O N' r W W V II 0 Z ; 111 F= _ ' 0 ' Project: K f igs / > Type f Inspection: /2 ,i2// c& Address: 5 ?35 a j�,. � - at called: De : 1 fig /0i Special instructions: C Date want d: / / / a.m. cf: Re }R!est r: fM Phone: a ' D ( v -5 '7 - -a OVU INSPECTION NO. Approved per applicable codes. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 9818 ditiktiailtiamitowiletTswiStakkrgmaCeirAbrea r. I. f t o uD . 3(5 7 ::71 PERMIT PERMIT NO. (206)431 -3670 Corrections required prior to approval. COMMENTS: Date: i / 0 $47.00 REINSPECTION FEE REQUIRED Prior to inspection, fee must be paid, at 6300 Southcenter. BIvd,,,Suite 100. Call to schedule reinspection. Receipt No: Date: w.y,.it::rs t ,,..:,s5... .t.ri *.;.;vri'._d.e. t1:V 1.1tPia2..C.Lit. d a .1tiCF'.':1Gia vi1„fYhu'l v.'f :SB. Y irLi. ii /t'�3�. Yb ! 7i Jf�d #, L1P�YNkii.1..ii>mli: Project: � 04 j/ia,n � \ -. - y/S C., Type of Inspecti�i. /) vf&1j i / Address: 9T;75 5.fale P/ or Date alle : /0161 Special instructions: „/ e. / Datg a ted: / ��/O j a m. p.m. Re T Phone: BOG - 5'25. 255' Approved per applicable codes. INSPECTION RE RD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 C IMIT NO. (206)431 -3670 9L COMMENTS: ,v( n". f� 1� 4(-) �Y Pic" vrVIA r /A.Ae.rt,. c'� v.% A-- V C, V « v\ 5 ay. 7 0ti . 14\ 4 5. pp vs. wn1oeh r��v"'t►� ex n, e1'.;) EC C1)\1 (DV\ 1 :tn- 1 r)1.4442 Iroovv, pe eIQCA-r 1(,J C 4,1 to 4 'I r) Inspector: Date: Corrections required prior to approval. E $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, ee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: .F .Wlth r'a t.YL'.: Lei: :*^ .eMAr,.niura gteii # .r Hwd„ thrii Project: `u / Litef Type of Inspection: . 50.6 Address• ( � 5. 35 a e { ? a ,, k. c 7 r Date called: / a/w Special instructions: Date wanted: ///4 a. m. Requester: Phone: 2 oe,, - 5 P?s 255 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 COMMENTS: 1) ) b (. N-, ,, �r,.2 6/' 1 c'' 7' ' r — /a ( h.v lei '�'iG•l�T.f' /44 /1 17J-7,e coo Z9 /4v • 0 Approved per applicable codes. 0 $47.00 REINSPECTION � EE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection. Receipt No: Date: t@rT 't er+.air� ix:s s t�.:S s p 1—J t.1he e INSPECTION RE • RD Retain a copy with permit Corrections required prior to approval. s �r 1.a�naa'�ad�s.M•t r �..._ k:Lx �,hrc2�eu+ni �s 3�na�,>. �U+ �. Na, 441:414.14"14b. *1.0 .. _ 3 �u.,, 1; .��,r :z�:�.,t>.n.i'�.n Sprinklers: Fire Alarm: W\o,•■n Hood & Duct: Halon: Monitor: �• Pre -Fire: Permits: Suite AP. v 0 Date f {� u't lt �'„- �b� }J� v� a �;�{„�SS+�'SU•. W. �t' v+.i �.:� 1�e'J t'1 r�v.r'•�. y..., . � -1�,( n.' f.^ G:4s,g.y ., x,.. '.Y� .l fx City of Tukwila John W. Rants, Mayor Fire Department Thomas P. Keefe, Fire Chief TURWILA•FIRE DEPARTMENT FINAL APPROVAL 'FORM )Retain current-inspection schedule shift inspection N C ,\ Q Approved without correction notice _ Approved with correction notice issued Authoried Signature Permit FINALAPP.FRM T.F.D. Form F.P. 85 • Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 5754439 z fe 0 0 N 0 w w '. CO LL J w o ; g w ill = w ' Z F- O w ~� 0 0 0H w O ' iii z 0 z Nov -28 -00 10:52A Franklin Engineering FRANKLIN ENGINEERING MF:GHANIC.AL CONSULTING October 16, 2000 RE: Landsberg `I'1 Heated space applies to office space. Vertical Glazing Type 1(Exterior): U =0.60, SC =0.64. Unlabeled glazing - 1/2" space Air, law -e (0.40), fixed, default. Or certified tested assembly per NFRC. Vertical Glazing Type 2 (Warehouse): U =0.75, SC =1.0. Unlabeled glazing - 1/2" space Air, fixed, default. Or certified tested assembly per NFRC. RECEIVED CITY OF TUKWILA Doors (Opaque): Wood, U=0.5, default. NOV �Vi Wall Type 1 (Opaque, Exterior): Concrete, 6 ", furred with metal studs, 3 -1/2 ", 24" oc wit AMIT CENTER R.11 halt insulation, t1 -0.11, calculated. Wail Type 2 (Opaque, Warehouse): Metal studs, 3 -1/2 ", 24" oc with R -11 batt insulation, U - 0.13, default. Slab on Grade: No Insulation. Please note that these values are minimum insulation for code compliance. Higher insulation values may be installed. SC = Shading Coefficient 1,904 'T'hir,1 Avenue Suirc 256 Seattle WA o&1O1 206!"23 -7403 ENVELOPE SUMMARY F'FI 200 623 -72F 3 FAX 206 623 -7403 frmnkliri lwolferiet.000.1 P.02 Space Heat Type 0 Electric resistance n All other (see over for definitions) Glazing Area Calculation Note: Below grade wells may be included in the Gross Exterior Wall Area if they are insulated to the level required tor opaque walls. Total Glazing Area Electronic version: these values are automatically taken from ENV -UA -1. (rough opening) Gross Exterior (vertical & overhd) divided by Wall Area times 100 equals V. Glazing 897.0 3672.0 X 100 = 24. Concrete/Masonry Option 0 yA6 Check here if using this option and if project meets all requirements for the ConctelciMaaonry Option. See Decision Flowchart (over) for qualfications. Enter requirements for each qualifying Q nd assembly below, Project Info Project Address Landeberg TI Date 10/16/00 991 Dui ldina For Building Department Use Tukwila, WA Applicant Name: Applicant Address: Applicant Phone: P4ov -28 -00 10:52A Franklin Engineering 1997 Washington State Nonresidential Energy Code Compliance Form Envelope Summary Climate Zone 1 ENV -SUM 17'31 Wastungton Elam Non -e derwel Energy Code Carnmionoe Forms Project Description [1 New Building ❑ Addition 0 Alteration ❑ Change of Use Compliance Option Envelope Requirements (enter values as applicable) Fully heatad/cooled space Minimum Insulation R- values Roofs Over Attic All Other Roofs Opaque Walls Below Grade Walls Floors Over Unconditioned Space Slabs-on-Grade Radiant Floors Opaque Doors Vertical Glazing Overhead Glazing Maximum U- factors Vertical/Overhead Glazing Maximum SHGC (or SC) Seml-heated space' Minimum Insulation R- values Roofs Over Semi - Heated Spaces* ❑ Prescriptive j0 Component Performance (See Decision Flowchart (over) for qualifications) 'Refer to Section 1310 for qualifications and requirements Notes: See Summary Sheet 206•'°23 -7403 P. 03 First Eatmn Jun. 1996 ❑ ENVSTD ❑ Systems Analysis Opaque ConcretelMaeonry Wall Requirements Insulation on interior- maximum U - factor is 0.19 Insulation on exterior or integral - maximum U- factor is 0.25 If project qualifies for ConcretelMasonry Option, list walls with HC 'a 9.0 Btu/ft-°F below (other walls must meet Opaque Wall requirements). Use descriptions and values from Table 20-5b in the Code. Wall Description (Including insulation R•value & position) U- factor Project Address Landebrarg TI Date 10/16/00 Space Heat Type 0 Electric resistance U All other For Building Department Use Glazing Area as % gross exterior wall area 24.4% Prop. 40 , 0% Max.Target Concrete/Masonry Option 0 Yes QQ No Notes: If glazing area exceeds maximum allowed in Table, then calculate adjusted areas on back (over). If Concrete /Masonry Option is used, Target U- factors, SHGC and Glazing % will be different than shown below. Refer to Table 13 -1 for correct values. Building Component List components by assembly ID & page # Proposed UA U4actor x Area (A) = UA (U x A) Target UA U- factor x Area (A) = UA (U x A) 6urretD I U= 0.600 Plan ID Exterior U= 0.750 Plan ID Warehouse U= ' Plan ID: U= Plan ID: U= Plan ID: . U= Plan ID: U= Plan ID: 0.600 885.0 531.0 0.750 12.0 9.0 0.600 897.0 538.2 Glazing % Electric Resist. Other Healing 0 -15% 0.40 0.90 >15 -20% 0.40 0.75 >20 -30% not allowed 0.60 >30 -'40% not allowed 0.50 (see Table 13 -1 for ConclMasonry values) l Overhead Glazing sMUV/ JaAO U= Plan 1D: U= Plan ID: U= Plan ID; U= Plan ID: Glazing % Electric Resist. Other Heating 015% 0.80 1.45 >15 -20% 0.80 1.40 >20 -30% not allowed 120 >30 -40% not allowed 1.25 (see Table 13-1 for Conc./Masonry values) Oth.Roofs U= PIan ID: U= PIan ID: U= PIan ID: U= Plan ID: I Opaque Doors U =0.500 PIan ID wood U= PIan ID: U= Plan ID: 0.500 126.0 63.0 0.600 126.0 75.6 Eledric Resist. Other Heating 0.60 0.60 a.nµp JOAO R= Plan 10: R= Plan ID: R= Plan ID: Electric Resist. Other Heating 0.031 0.036 Sj00H JOIE) R= PIan ID: R= PIan ID: R= Plan ID: Electric Resist. Other Heating 0.034 0.050 ,silent an PIan ID Yurrad concrete R =11.0 Plan ID Interior metal R= Plan ID: R= PIan ID: R= Plan ID: R= PIan ID: R= Plan ID: **Note: sum of Target Areas here should equal 0.110 1155.0 127.1 0.130 1494.0 194.2 Tar>iet Opaque Wall Area (see back) 0.140 2649.0 370.9 *• .. Electric Resist. Other Heating Ordinary 0.062 0.14 Metal stud 0.11 0.14 Conc(int) 0.19 0.19 Conc(oth) 0.25 0.25 . up o a R= PIan ID: R= Plan ID: R= Plan ID: Note: if insulated to levels required for opaque walls, list above with opaque walls Electric Resist. Other Heating Ordinary 0.062 0.14 Metal stud 0.11 0.14 puwuI 1 MO GIMI I R= PIan ID: R= PIan ID: R= Plan ID: R= Plan ID: Electric Resist. Other Heating 0,029 0.058 {11C!PNI 1 ape16 .1 ln.nol0 _ R= PIan ID Unineulated R= Plan ID: R= Plan ID: R= Plan ID: 0.730 306.0 223.4 0.540 306.0 165.2 Electric Resist. Other Heating F =0.54 F =0.54 (see Table 13 -1 for radiant floor values) Nov -28 -00 10:62A Franklin Engineering 206.' 1997 Washln.lon State Nonresidential Energy Code Compliance Form P.04 Envelope UA Calculations Climate Zonel ENV -UA 1997 Weatenoton state Ncnroaidenl.I Energy Code Compli ice Rani FiretE5t,on, June teie For CMU walls. indicate core insulation material, Totals 3978.0 1147.7 Totals 3976.0 1149. For compliance: I 1) Proposed Total Area shall equal Targ t 1 crarnrea, ana roposea I our UA shall n t exceea I arget mat UA Glazing List components by assembly ID E. parse # Proposed SHGC SHGC• x Area (A) = SHGC x A Target SHGC SHGC x Area (A) - SHGC x A 6urcelo I ID:r,xtr-le- :.:1o'ir i l r'i•w i'r'J ID. ID: ID: ID: 0.640 885.0 566.4 1,000 12.0 12.0 0. 650 897.0 583.1 Glazing % Electric Resist. Other Heating 0.20% 1.00 1.00 >20-30% not allowed 0 65 >30 -40% not allowed 0 45 (see Table 13-1 for Conc/Masonry values) •Note: Manufacturer's SC may be used in lieu of SHGC. Totals) 897.0 578.4 Totals 897.0 583 Mov -28 -00 10:52A Franklin Engineering 1997 Washington State Nonresidential Energy Code Compliance Form Climate Zone 1 ENV -SHGC p 1097 Wnin9ton Stem re Nonsdenllel Fner9Y Code Compiurtr:o Fortin P roposed to SHGC x A shall not exceed Target total SHGC x A NOTE: 1997 NREC revisions allow SHGC compnance for vertical and overhead glazing to be calculated together. The 1994 Forms required separate calculations for vertical and overhead glazing. Target Area Adjustment Calculations [ 3672.0 If the total amount of glazing area as a % of gross exterior wall area (ce then this calculation must be submitted Use the resultin Glazing Area Opaque Area Gross Exterior Wall Area 1468.8 Proposed Areas: Numbered values are used in calculations Roofs over Attics Other Roofs OG= OG= x Max Glazing Area (Table 13 -1) 40.0% II lesser 206 X23 -7403 Target OG Area in Roofs over Attics 1 goo � Max OG Remaining = 1 1468.8 P.05 irst Eaton June 1.7w VG -4 w 0; to 0 N u w 0 t- ? I- 0. z f.., W w U 0 '0 — o u Z ' I =i ` 0 z Layer Description Detail R-value Exterior Moving Air ....e ,-.... a t 7 o Surtace Concrete 8' VS 1 A 3-1t2" mti, 24"oc R-11 8,60 • 8 C GWB 58" .. 0.50 D E Interior Stilt Air ,ei- Arok-.• 0.68 Surface 1. Total Column 8,73 2. U-value, invert amount in line 1 0.11 , Nov-28-00 4 1053A Franklin Engineering ( 1 FRANKLIN ENGINEERING MEL'..I.ANT.TAL i,;;OINI!!..1.ILTI NG 1904 Thr.1 Avormic ejtiite C WA (.43.1 Wall U-value Calculation - Conc wiint insul. 206" P.06 1"I i FAX ;?.(::;0 it'ar liriOw 01 Icri r ' • - 9 1- u) uJ 2 g (C Z I- 01 Z 0; DEPARTMENTS: Build9ng Division (2 00 Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) WRROUIt.DOC Complete U Incomplete Comments: TUES /THURS ROUT NG: Please Route Structural Review Required REVIEWER'S INITIALS: REVIEWER'S INITIALS: CORRECTION DETERMINATION: Approved n Approved with Conditions Fire Prevention Npv 12.440 n Structural II II REVIEWER'S INITIALS: PERMIT C B PLAN REVIER��f�NG SLIP ACTIVITY NUMBER: D2000 -382 DATE: 11 -29 -2000 PROJECT NAME: KENT H. LANDSBERG SITE ADDRESS: 5835 SEGALE PARK DR C' SUITE NO: Response to Incomplete Letter # XX Original Plan Submittal Response to Correction Letter # Revision # After Permit Is Issued Planning Division Permit Coordinator DUE DATE: 11 -30-2000 Not Applicable No further Review Required I I DATE: DUE DATE 12- 28-2000 APPROVALS OR CORRECTIONS: (ten days) Approved n Approved with Conditions Not Approved (attach comments) DATE: II DUE DATE Not Approved (attach comments) II DATE: F625.052.000 (8/97) • DEPARTMENT OF LABOR AND INDUSTRIES REGISTERED AS PROVIDED BY LAW AS CONST CONT GENERAL REGIST_ $ EXP'. - DATE CCO1 LAPIAL *008J8 04/01/2001 EFFECTIVE DATE . -04/28 LA PIANTA LLC PO BOX 88028 TUKWILA WA 98138 -2028 Detach And Display Certificate tu (o( w 0: g u. N H uj Z E Z I- Lu j0 - 0 t ; = Ui 0 N` ` 0 � SEGALE BUSINESS PARK KENT H. LANDSBERG CO. 5835 SEGALE PARK. DRIVE C TUKWILA WA 98188 BUILDING 981 CONTINENTAL MILLS SEGALE DRIVE "C" GRAPHIC° SCALE 50 75 WO ( IN er ) Inch = 50 (L Dz oo c SEPERATE PERMIT REQUIRED FOR: 1. MECHANICAL - BY WASH. STATE UCENSED ENGINEER 2. ELECTRICAL - BY WASH. STATE LICENSED ENGINEER 3. FIRE SPRINKLER - BY WASH. STATE LICENSED ENGINEER PROJECT STATISTICS: TOTAL BUILDING AREA = 312,205 S.F. THIS TENANTS AREA = '..62214.S.F. WAREHOUSE 5,516 S.F. OFFICE TOTAL = 67,730 S.F. PARKING REQUIRED = 47 STALLS PARKING PROVIDED = 47 STALLS ZONE',- TUC CODES - 1997 UBC, TUKWILA ZONING CONSTRUCTION TYPE - IIIN OCCYPANCY GROUP - S 11111111 understand t?ia: the Plan Check approvals are su fect,to eoors and omissions and approval of o!a s does not authorize the violation of any adopted code or ordinance. Receipt of cum tractor's copy of approved plans acknowledged. B Date Permit No. FILE COPY SEPARATE PERMIT REQUIRED FOR: 2 MECHANICAL E ELECTRICAL PLUMBING ❑ GAS PIPING CITY OF TUXWILA BUILDING DIVISION REVISIONS NO CHANGES SHALL BE MADE TO THE SCOPE OF WORK WITHOUT PRIOR A'ROVAL OF TUKWILA BUILDING OIVI ^'•:J, VICINITY MAP NTS Z Cl_ I LiJ H z co CC W W� 2 RECEIVED CITY OF TUKWILA PERMIT CENTER sheet W 2 i KENT H. LANDSBERG CO. 5835 SEGALE PARK DRIVE C TUKWILA WA 98188 325 -6" THIS PERMIT OVERALL FLOOR PLAN 1/32" = 1'-0" CONTINENTAL MILLS 390' � 200 '382 30' 351' 30' CITY DF T06WIU APPROVED DEC - 5 2000 AS 601E0 SEPERATE PERMITS REQUIRED FOR: 1. ELECTRICAL 2. MECHANICAL 3. FIRE SPRINKLERS' 4. PLUMBING 1 0 C RECEIVED ciry of ruNrviw PERMIT CENTER sheet Ti- U7 i . �r DOOR SCHEDULE DOOR NO. H)-dw DESCRIPTION DOOR FRAME HARDWARE GROUP RATING REMARKS MAT. FIN. MAT. FIN. 101 C 3' -0" x 7-0 H.M. METAL PAINT METAL PAINT E - NARROW RELITE 102 D 3' -0 x 7-0" S.C. WOOD STAIN METAL PAINT E - NARROW. RELITE 103 C 3' - x 7-0 H.M. METAL PAINT METAL. PAINT D.. - - 104 C 3' -0" x 7-0 H.M. METAL PAINT METAL PAINT ; D - - 105 C 3' -0 x 7-0 H.M. METAL PAINT METAL PAINT A - 106 C 3' -0" x 7-0 H.M. METAL PAINT METAL PAINT A - - 107 A 3' -0 x 7' -0° . S.C. WOOD STAIN METAL PAINT H - - 108 A - 3' -0 x 7-0 S.C. WOOD STAIN METAL PAINT C - - 109 A 3' -0 z 7-0" S.C. WOOD STAIN METAL PAINT H - - 110 A 3' -0 x 7-0" S.C. WOOD STAIN METAL PAINT B - - 111 A 3' -0 x 7' -0° S.C. WOOD STAIN METAL PAINT E - -. 112. A 2' -6 ° x 7' -0° S.C. WOOD STAIN METAL PAINTS B - - 113 A 3' -0" z 7' -0° S.C. WOOD STAIN METAL PANT 114 A 3' -0" x 7' -0° S.C. WOOD. STAIN METAL PANT G - - 115 A 3' - 0" z 7-0 S.C. WOOD STAN METAL PAINT G - - 116 A 3' -0 z 7' -0 "' S.C. WOOD STAIN METAL PAINT G -. - 117 B 3' -0" z 7' -0° S.C. WOOD STAIN METAL PAINT I NARROW. RELITE 118 A 3' - 0° z 7' -0° S.C. WOOD STAIN METAL PAINT B - 119 A 3' -0' x 7' - S.C. WOOD STAIN METAL PAINT G - 120 A 3' -0" x 7-0 S.C. WOOD STAIN METAL PAINT G - 121 3' -0 x 7' -0" METAL EXISTING METAL EXISTING - - - 122 3' -0" z 7' -0" .ALUM_ EXISTING ALUM.. EXISTING - - -. LIGHTING BUDGET DESCRIPTION WINDOW SILL 2' X 4' LAMP FLUORESCENT LAY -IN WITH 3" DEEP 96 61 SEMI - SPECULAR PARABOLIC LOUVER (18 CELL) HUBBELL #RD- 3- G- S- Z- AF- B- 4- E -1A -31 1' x 4' LAMP WRAPAROUND FLOUESCENT 64 7 HUBBELL # WG- M- 4- 2 -W -AC TOTAL SHOWN TOTAL ALLOWED 5297 SF x 1.2 WATTS DAYLIGHT SWITCHING ON ALL FIXTURES WITHIN 15 FEET OF NATURAL LIGHT CLEAR GLASS IN HOLLOW METAL FRAME WATTS NUMBER TOTAL WATTS 5856 448 6304 6356 REFLECTED CEILING PLAN 1/8" = 5/8" TYPE 'X' G.W.B. EA. SIDE ON 3 1/2" METAL STUDS at 24" 0.C. O DOOR JAMB O O O DOOR TYPES ALL DOORS LEVER TYPE HANDLES H.M. DOOR FRAME 3 SILENCERS at STRIKE SIDE H.M. DOOR (PAINTED) CABINET BY TENANT ENLARGED FLOOR PLAN = 1 ' - CITY OF TUKWIIA APPROVED DEC - 5 2000 AS 50150 '.. eun_0545 DM 1 ENLARGED PLANS & DETAILS BUILDING 981 - TENANT 2 . LANCE MUELLER S. ASSOCIATES "N, ------, 'i ,, Mill MIMI fillIlljlln/ 4/0o II 4-\ •• 130 LAKESIDE • SEATTLE, WA 98122 • 206 325 2553 EN ROOM FINISH SCHEDULE ROOM NO ROOM NAME', FLOOR BASE NORTH WALL SOUTH WALL EAST WALL WEST WALL WAINSCOT CEILING REMARKS MAT. FIN. MAT. FIN. MAT. FIN. MAT. FIN. MAT. FIN. MAT. FIN. MAT. FIN. MAT. FIN. 1 HT. 101 VESTIBULE CONCRETE : - RUBBER FACTORY GWB', PAINT GWB PAINT '..GWB PAINT GWB PAINT', - - ACOUST. FACTORY 9' -0" PAINT 102 SALES CARPET FACTORY RUBBER FACTORY GWB PAINT GWB PAINT GWB PAINT GWB PAINT - - ACOUST. FACTORY 9' -0" - 103 WOMEN C.T. FACTORY .. C.T. FACTORY GWB PAINT GWB PAINT GWB PAINT. GWB PAINT C.T_ FACTORY GWB PAINT 8' -0" SIGN - "WOMEN" 104 MEN C.T. FACTORY C.T. FACTORY GWB PAINT GWB : PAINT GWB PAINT GWB PAINT C.T. FACTORY GWB PAINT 8 " -0" SIGN - "MEN° 105 OFFICE CONCRETE - RUBBER FACTORY GWB PAINT GWB PAINT GWB PAINT GWB PAINT - - ACOUST_ FACTORY 9' - 0" - 106 OFFICE CONCRETE - RUBBER FACTORY GWB PAINT GWB PAINT GWB PAINT GWB PAINT - - ACOUST. FACTORY 9' -0" - 107 MEN C.T. FACTORY C.T. FACTORY GWB PAINT GWB PAINT GWB PAINT GWB PAINT C. FACTORY GWB PAINT 8 " -0" SIGN - "MEN" 108 JANITOR VINYL FACTORY RUBBER FACTORY GWB PAINT GWB PAINT GWB PAINT GWB PAINT. - ACOUST. FACTORY 9 -O - 109 WOMEN C.T. FACTORY C.T. FACTORY .GWB PAINT GWB PAINT GWB PAINT GWB PAINT C.T. FACTORY GWB PAINT 8' -0" SIGN - "WOMEN 110 LUNCH VINYL FACTORY RUBBER FACTORY GWB PAINT GWB PAINT GWB PAINT. GWB PAINT - - ACOUST. FACTORY 9' -0" - 111 HALL CARPET FACTORY RUBBER FACTORY GWB PAINT GWB PAINT GWB PAINT GWB PAINT - - ACOUST. FACTORY 9' - 0" - 112 STORAGE VINYL FACTORY RUBBER FACTORY GWB PAINT GWB PAINT GWB PAINT GWB PAINT - - ACOUST. FACTORY 9' -0" - 113 TEL /SERVER VCT FACTORY RUBBER FACTORY GWB PAINT GWB : PAINT GWB PAINT GWB PAINT - - ACOUST. FACTORY 9' -0" - 114 OFFICE CARPET FACTORY RUBBER FACTORY GWB PAINT GWB PAINT GWB PAINT GWB PANT - - ACOUST. FACTORY 9' -0" - 115 OFFICE CARPET FACTORY RUBBER FACTORY GWB PAINT GWB PAINT GWB PAINT GWB PAINT - - ACOUST. FACTORY 9 " -C" - 116 OFFICE CARPET FACTORY RUBBER. FACTORY. .GWB PAINT GWB PAINT GWB PAINT - GWB PAINT - - - ACOUST FACTORY 9 " -0" - 117 RECEPTION CARPET FACTORY RUBBER FACTORY GWB PAINT GWB PAINT GWB PAINT GWB PAINT - - ACOUST_ FACTORY 9' -0" - 118 CONFERENCE CARPET FACTORY RUBBER FACTORY GWB PAINT GWB PAINT GWB PAINT GWB PAINT - - ACOUST_ FACTORY 9' -0 - 119 OFFICE CARPET FACTORY RUBBER FACTORY GWB PAINT GWB PAINT GWB PAINT GWB PAINT - - ACOUST_ FACTORY 9' -0" - 120 OFFICE CARPET FACTORY RUBBER FACTORY. GWB PAINT GWB PAINT GWB PAINT GWB PAINT - - ACOUST_ FACTORY 9' -0" - 121 COPY /SUPPLY CARPET FACTORY RUBBER FACTORY GWB. PAINT GWB PAINT. 'GWB PAINT GWB PAINT.. - ACOUST. FACTORY 9' -0 " 122 OPEN. CARPET FACTORY RUBBER FACTORY GWB PAINT GWB PAINT GWB PAINT GWB PAINT - - ACOUST. .FACTORY, 9' -0 " 123 OFFICE CARPET FACTORY RUBBER FACTORY GWB PAINT � GWB PAINT ',GWB PAINT ''. GWB PAINT - - ACOUST. FACTORY, 9' -0" 124 DISPLAY - AREA. VCT FACTORY RUBBER FACTORY GWB. PAINT GWB PAINT ',GWB PAINT GWB PAINT - NONE - - RELITE'', SCHEDULE ROOM NO_ F Y CL DESCRIPTION FRAME : GLASS REMARKS MAT FIN... 105 R4 4' -0 x 3' -2" ALUMINUM FACTORY CLEAR - 106 R4 4' -0" x 3' - ALUMINUM FACTORY CLEAR - 106 R2.. 3' -0" x 3' -2" ALUMINUM FACTORY : CLEAR 114 RI. 2' - x 6' -2" METAL PAINT CLEAR 115... RL 2' - x 6' -2" METAL PAINT CLEAR 116 01, 2' -6 x 6' -2" METAL PAINT CLEAR - 117 R3 5' -0" x 3' -2" ALUMINUM FACTORY CLEAR 118 : 01 2' -6" x 6' -2° METAL PAINT. CLEAR 119 RI 2' -6" x 6' -2 METAL PANT CLEAR 120 RI 2' -6" x 6' -2" METAL PAINT CLEAR '.. 1 SINK SHALL BE N01 MORE THAN 6 1/2" IN VERTICAL DEPTH 6'-2" I' O" E R1 RELITE ELEVATION CLEAR GLASS IN HOLLOW METAL FRAME PER 1/ TI2 ///��- BASE PER SCHEDULE 30" x 48" I CLEAR SPACE 5' DA. CIRCLE DOOR MAY INCLUDE 12' i TOILET MAY INCLUDE 6" CD R2 RELITE ELEVATION R4 SIM. C.T. WAINSCOT GRAB BARS-. FLUSH CONTROL ON THIIS SIDE CLEAR GLASS IN ALUMINUM FRAME P. LAM. PARTITION ±� r MIN. 17._I HOT WATER AND DRAIN PIPES EXPOSED UNDER LAVATORIES AND SINKS SHALL BE INSULATED._ THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER LAVATORIES OR SINKS. MIRROR KNEE 2 -9 CLEAR NOTE: LEVER TYPE FAUCET CONTROL HANDLE SHALL BE LOCATED NOT MORE THAN 17" FROM FRONT EDGE OF LAVATORY SINK. O R3 RELITE ELEVATION TOILET ROOM ELEVATION MENS SHOWN- WOMENS SIM. 3 /8" = 1' -0" `2000 -3gZ 80 OF TUI(WIU APPROVED DEC -5 2000 AS Nita, to 4 td m 4 J 1® sheet TI LA Suspension not smaller than #12 gage spaced 4' oc or PO gage spaced at 5' oc along each main miner Each wire shall be attached to the ceiling member and to the support above with a minimum of three turns. Wires shall not be more than Ito 6 out of plumb unless c untersloping wires are provided. Wires shall not attach to or bend around interfering objects er equipment. The terminal ends of each cross runner one. .main r shall be supported x independently a m of 8" from each wail or ceiling discontinuity of other approved all support. Where substantiation design calculations are not provided, horizontal restraints shell be effected by four #12 gage wires scured to the runner main within two inches of the intersection of the cross runner and splayed 90 degrees from each other or an angle not exceeding 45 degrees from the plane of the ceiling. These horizortol resboints shall be placed not more then 12' oc in both directions and with the first point within 6' from each wall. Attachments of the restraint wires shell be adequate to resist the loads imposed. Only "intermediate and heavy duty "grid as defined by Section 47.1802 shall be used to support of lighting fixtures. All lighting fixtures shall be positively attached to the amid system_ When intermediate systems are used, #12 gage hangers shall be attached to the grid within 3 of each corner of each fixture. Supplemental hangers ore not required with a heavy duty system if a 48" modular hanger pattern is followed- Lighting fixtures weighing less than 56# shall have in addition to the requirements above, two #12 gage hangers connected e fixture housing to the structure above. These w may be slack. Pendent -hung righting om r ghting fixtures shall be supported directly from the structure above with #9 gage wire or approved alternate. Ceiling mou^.ted a r- termincl a weighing less thou 20# shall be positively attached to the main runners or cross runners with h�same carrying capacly as ;he main unner. Where the suspended ceiling system is required to provide lateral support for permanent or relocate. partition, all components et the system shall oe designed to support the reaction force of the partition from prescribed loads perpendicular to the. face of the partition. These loads shall be in addition to the loads described in Section 25.211. Engineering shall be required to suit individual partition applications and be shown on the approved drawings. The drawings shall clearly identify all systems and shall define or show all supporting details, lighting fixture attachment, lateral force bracing, partition bracing, etc. © FIXTURE TENT EXISTING P.C.C. PANE6� EXISTING 1" INSULATED GLASS ALUMINUM STOREFRONT FRAMES SUSPENDED CEILING ALU!@70M HREAK 'HAP - i� SH.L TO MATCH STOREFRONT FLOOR COVERING AND BASE PER SCHEDULE R -19 BATT INSULATION WITH VAPOR BARRIER AT WAREHOUSE CEILING EXISTING BEAM OR JOIST ABOVE DO Y382 twoMImI 3 1/2" 20 GA METAL STUD WALL WITH GWB BOTH SIDES - FINteH PER SCHEDULE RAM -SET AT 24' OC RAM -T AT 24' E OC LONG -LEG TRACK SUBPURLIN PROVIDE R11 BATT INSULATION AT WAREHOUSE WALL AND WHERE SHOWN ON PLAN FOR SOUND CONTROL 050 WAREHOUSE :. SIDE TAPED AND READY FOR PAINT z RECEIVED Cltt OF TUKWILA PERMIT CENTER sheet iJ liJ ct 0 Y E - d 1 2 - w z Z as z : m w • W O N 2 Y (/1 o w . J (n N tp - • N WI • o MEZZANINE PLAN a T 981 TENANT 1 / p e "� C -- BUILDING 81 1 ENANT F.., Job no. LANCE MUELLER 6 A n c N i T E C T 130 LAKESIDE • SEATTLE, ASSOCIATES- S •A I A WA 98122 206:325 2553 drawn TUKWILA, WASHINGTON for SEGALE BUSINESS PARK - -- _ ne REGISTERED AR -y; �� U/NGEP �srnrz ov Riei iox checked 11/14/00 date no.. revision. date