HomeMy WebLinkAboutPermit 1616 - Southcentert Mall - Athlete's FootBUILDING PERMIT
PNEUILMBVR I ID I (0
CITY OF TUKWILA
6200 SOUTHCENTER BOULEVARD
TUKWILA, WASHINGTON 98188
DATE OF ISSUANCE
31 October 1978
EXPIRES
1 March 1979
JOB ADDRESS
610 Southcenter Mall
LEGAL
DESCR.
LOT NO.
BLOCK
TRACT a SEE ATTACHED SHEET
OWNER
Franchise Developigent Corp/ The Athlete's Foot
PHONE
ADORess1200 5bh Ave., Seattle (ZIP 98101
CONTRACTOR
McAbee Construction
PHONE
524 -8785
ADDRESS
9510 Stone Ave. N., Seattle
ZIP
98103
LICENSE NO.
223 01 Mc Ab EC 260 JA
SST NO.
- --
BUILDING USE
Retail sales
CLASS OF WORK
❑ NEW ❑ ADDITION ❑ REMODEL ❑ REPAIR IN OTHER (Specify) Tenant improvement
I CERTIFY THAT THE ABOVE INFORMATION IS TRUE AND CORRECT,
THAT THE APPLICABLE CI. • TUKWILA REQUIREMENTS WILL BE
%M
MET, AND THAT I AM A ORIZED AGEN FO THE PROJECT.
OWNER /AGENT SIGNA - -E
THESE INSPECTIONS ARE REQUIRED BY LAW
1. Driveway
2. OK to
3. Roof
4. OK to
5. Wall-
6. Structure
approach and
pour footing
sheathing
enclose
board nail-
complete and/
slope
and /or
foundation
and nailing
OK
framing
ing OK
or OK to
occupy
FOR INSPECTION CALL 433 -1849
BUILDING OFFICIAL, CITY OF TUKWILA
THIS PERMIT MUST BE POSTED CONSPICUOUSLY ON BUILDING
f'r"•'..".7r7T'ITTH77rt'77.r:-'r'rr:rr;;T'r!777nr7:'..77r. 1!,.■ rP!:1-777".Vr.tr,rtfrrr:r.,-.., 7.tr ,I.-7.7t77"71
• •
• "W, • • "
di
(:I) (
BUILDING
PERMIT .1 to
NUMBER
CITY OF TUKWILA
6200 SOUTHCENTER BOULEVARD
TUKWILA, WASHINGTON 98188
DATE OF ISSUANCE
„ . 31 October 1978
EXPIRES
1-March 1979
JOB ADDRESS
610 Southcenter Mall
• LEGAL
DESCR.
LOT NO.
BLOCK
TRACT XI SEE ATTACHED SHEET
OWNER . '
i-ranchise Development Corp/ The Athlete's Foot
PHONE
ADDRESS 1200 5 bh Ave., Seattle ,
ZIP
98101
CONTRACTOR
McAbee Construction '
PHONE •
ADDRESS ,
9510 Stone Ave. N. Seattle . :.
ZIP 98103 .
...LICENSE NO.
223 01 Mc Ab EC 260 JA
SST NO.:
c. BUILDING USE
Retail sales
CLASS OF WORK
: CI NEW 0 ADDITION 0 REMODEL 0 REPAIR fiti OTHER (Specify) Tenant improvement
I CERTIFY THAT THE ABOVE INFORMATION IS TRUE AND CORRECT,
THAT THE APPLICABLE CITY OF TUKWILA REQUIREMENTS WILL BE . .•
' MET, AND THAT I AM AINI UTHORIZED AGEN F R THE PROJECT. .•
(IP • WV\ It 9 I) 9
OWNER/AGENT SIGNATURE
THESE INSPECTIONS ARE REQUIRED BY LAW
• 1. Driveway
2. OK to
3. Roof
4. OK to
. ,
5. Wall-
6. Structure
3/
approach and
pour footing
sheathing
enclose
board nail-
complete and/
1•17‘;
slope
and/or
and nailing
framing
Ing OK
or OK to
/
foundation
OK
occupy
(r-e0
FOR INSPkCTION CALL 433-1849
ARA-V2•1
BUILDING OFFICIAL, CITY OF TUKWILA
THIS PERMIT MUST BE POSTED CONSPICUOUSLY ON BUILDING
16/6
APPROVED
NOT APPROVED
INSPECTION
ITEM
DATE
INSPECTION
NAME
DATE
INSPECTOR'S
NAME
COR
NOTE
NOT
RDY
COMMENT
SETBACKS
STEEL
:...'
FOUNDATION
FOUNDATION GARAGE
.
FLOOR JOINTS & GIRDERS
PORCH & PATIO PIERS
TRUSSES
FRAMING . ..
/I /2.2
(it
FIRE RATED CONST.
FIREPLACE
SPRINKLER SYSTEM
SHOWER PAN & WALLS .
CLEAN UNDER FLOOR AREA
PRODUCT OF
COMBUSTION DECTOR
FINAL
APPLICATION FOR PERMIT
BUILDING DEPARTMENT
CITY of TUKWILA
6200 SOUTHCENTER BOULEVARD
TUKWILA, WASHINGTON 98188
433 -1849
CI Y OF 111.
OCT 20 1978
BUIWIING ()EP),
DATE /0/20/.00
'PERMIT N0. WHEN VALIDATED
EXPIRES
JOB ADDRESS SouZHGI TaYZ S?/ ID+
..il 1„1 -aC — 6 10 204Q -ni-co 1TEYL. MALLr
LEGAL
DESCR.
LOT 0. s -~
�,
q p..0
BLOCK 7
TRACT SO4,4,4414 e
❑ SEE ATTACHED SHEET
OWNER FYGtVldits cr idr,'l/.GCfipf?9s CU12P.
PHONE
' e ,
ADDRESS �,Ci O 4v-42. / S-G idt-t. wQ
ZIP 9�� `U%
CONTRACTOR f,1 LA Bap Coot/ s T.
PHONE 6a41-..„ 0 .9 e
ADDRESS - /SIU 5,7Ci/t%'L w3{/( Aj / �P..L$[ �Q
ZIP 9[+��U 'L
C� m,7
LICENSE NO 2 .a 3 -01 Mc. 4e. iF c. a G 0 TA
SST NO,
BUILDING USE R��1,' i
TENANT 1-74,1x ,-1,14,LE re (-bar,
CLASS OF WORK
❑ NEW ❑ ADDITION ❑ REMODEL ❑ REPAIR MOTHER (Specify) 7-C let ap%J yv1v In v.. ,`yj
BLDG.
AREA
1st FL.
2nd FL.
BASEMENT
GARAGE
DECK
MEZZANINE
# OF STORES
TOTAL S.it. VALUATION
PLANNING/
SEPA
BOND
1/41Z, (o 3(..)1 000.00
NAME OF APPLICANT (PLEASE PRINT)
ip M t A sme. C c'At Gr.
ADDRESS 99 VQ 51m/ � /Vi Ccail e
PHONE 52.4 - E7
j
I CERTIFY THAT THE INFORMATION FURNISHED BY ME IS TRUE AND ORRE T AND THAT THE APPLICABLE CITY OF
TUKWI LA REQUIREMENTS WILL BE MET.
SIGNAT OF APPLI T
DO NOT WRITE BELOW THIS LINE
TYPE CONST,
OCC. GROUP
0CC)C, LOAD
FIRE ZONE
USE ZONE
AUTO SPRINKLERS REQ.
V- N
(3 Z
1j7
C p R
❑ YES ❑ NO -.\IZ%
--
PLAN
RVW.
PLANS:
SENT
RETURNED
APPROVED
FEE
DISTRIB.
BUILDING
FIRE DEPT.
to _ ZU
r0 _ 2-
3. N , VS i.S
PLAN RVW.
$ $ , p0
DEMOLITIO
PLANNING/
SEPA
BOND
OTHER
PUBLIC WKS.
TOTAL
a %O . 00
RECEIPT NO.
COMMENTS:
APPROVED FOR INSURANCE BY:
a" P,(1--tt
(-
City of Tukwila
Edgar D. Bauch
Mayor
Hubert H. Crawl
Fire Chief
Fire Department Crawley
Al Pieper
Building Department
City of Tukwila
Dear Al,
Fire Prevention Bureau
October 26, 1978
Re: The Athlete's Foot
In reviewing the above mentioned project plans, please note
the following items:
1. Per UFC Sec. 10.104(b), "All doors in or
leading to exits shall be maintained openable
from the inside without the use of a key or
any special knowledge or effort at all times
when the building or area served thereby is
occupied."
2. Per UFC Sec. 10.113, "At every required exit
doorway, and wherever otherwise required to
clearly indicate the direction of egress, an
exit sign with letters at least 6 inches high and
readily distinguishable shall be maintained ".
3.. Maintain sprinkler protection for all enclosed
areas,
All modifications to sprinkler systems shall have
the written approval of the Washington Survey &
Rating Bureau, then of the Tukwila Fire Department.
No work shall commence without the approved drawings.
4, Fire extinguishers shall be provided per NFPA #10,
as a minimum requirement.
One dry chemical extinguisher rated 2 -A., 10 B:C
is required.
5. Per NFPA requirements, extinguishers with a gross
weight of 40 pounds or less shall be hung so that
the top of the extinguisher is not higher than 60
inches above the floor. Extinguishers weighing
more than 40 pounds, shall be hung so that the top
of the unit is not higher than 42 inches above the
floor.
Extinguishers shall be located so as to be in plain
view (if at all possible). If not in plain view,
they shall be identified with a sign stating,
City of Tukwila Fire Department, 444 Andover Park East, Tukwila, Washington 98188 (206) 575 -4404
The Athlete's Foot
5. .cont d..
"FIRE EXTINGUISHER' with an arrow pointing:
6, Wood used for this remodel shall be fire - retardant
treated.
7.. All interior wall covering materials shall be fire
resistive or shall be treated to be fire - resistive,
so as to result in a Flame - Spread Rating of at
least Class III (.Class II for Exit - ways).
A certificate of Flame - Spread Rating is required .
to be delivered to the Fire Department.
:Please. include these comments in your review of:the,above
' ment,i oned.`,project.
arshal.''
I
it HERR HOMES INC
2410 HARBOR AVE SW
ti SEATTLE MA 48126 ; u- .4.: ^`
JP
DIRECTOR
Wi
ACCOUNT %;,•1BER I EXPIRATION DATE
:,y
=+ 223 -01 j HE -RR- H *- *2680R 12-31 -78
DAY LEE PAY STATE OF WASHINGTON JOHN C. HEWITT
GOVERNOR DIRECTOR
DEPARTMENT OF LABOR AND INDUSTRIES
THIS CERTIFIES THAT THE PERSON NAMED HEREON IS REGISTERED AS PROVIDED BY LAW AS A
CONTRACTOR- GENERAL
BILLFOLD COPY OF YOUR LICENSE
>C
a. el
U r
z
>.
<0
LLv
0
2
0
U-
LL
0
U
0
0
0
W
o�
Q¢I
-i,
STATE OF WASHINGTON
CONTRACTOR - GENERAL
HERR HOMES INC
2410 HARBOR AVE SW
SEATTLE 'i WA 9,&126
ACCOUNT NUMBER
DIRECTOR
EXPIRATION DATE
;223-01
1 J-
HE-RR- H *- *2680R
12 -31 -T8
reflected ceiling plan
tra
demolition plan
floor plan
southcenter plan
athlete's foot
elevations
finish schedule
color schedule