Loading...
HomeMy WebLinkAboutPermit 1160 - Southcentert Mall - Baskin & Robbins - Tenant Improvement4DDRESS PHONE ■AME OF BUILDER The Glad Co. STATE LICENSE NO. 223 -01 -11846 SALES TAX NO. 4DDRESS 903 Broadway, Seattle 98122 PHONE 329 -5200 INSPECTION RECORD = OOTINGS BUILDING PERMIT VOID IF WORK IS NOT COMMENCED IN 120 DAYS March 29, 1977 ESTIMATED VALUE COMPLETED WORK $ 10,000.00 'OUNDATION PERMIT FEE $52.00 °RAMING PLAN CHECK FEE $34.00 LATE PERMIT FEE $ TOTAL FEE $ 86.00 GRo OCCUPANCY F -2 CONST. I II N DATE ISSUED July 29, 1977 FIRE ZONE 1 USE ZONE CPR EXPIRATON DATE 'INAL FIRE SPRINKLERS REQUIREDaYes MAX. OCC. LOAD 36 all No _OCATION OF WORK / NUMBER tL STREET ..OT DWNER BLOCK )ESCRIPTION OF WORK: 886 Southcenter Shopping Center SUBDIVISION Allied Stores Tenant Improvement. Name of Tenant: 31 Flavors Store joAltLy+ (b3(1-1,n,o Nature of Business: Ice Cream Parlor THIS PERMIT DOES NOT AUTHORIZE ANY WORK IN PUBLIC RIGHT -OF -WAY OR ON UTILITY EASEMENTS. SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, HEATING, VENTILATING OR AIR CONDITIONING. I HEREBY CERTIFY THAT NO WORK IS TO BE DONE EXCEPT AS DESCRIBED ABOVE AND IN APPROVED PLANS AND SPECIFICATIONS AND THAT ALL WORK IS TO CONFORM TO TUKWILA CODES AND ORDINANCES. CALL FOR INSPECTION BEFORE WORK IS CONCEALED OR POURING CONCRETE PHONE 242-2177 FINAL INSPECTION BEFORE OCCUPANCY CITY OTUKWILA BUILDING DEPAR'ENT 6230 Southcenter Blvd. Tukwila, Washington 98067 Phone: (206) 242 -2177 APPLICANT The Glad Co. y , a ,e,4 ,4 . SUBJECT T INFORMAT BUILDING DIRECTOR C OMPLIANCE WITH THE ORDINANCES OF THE CITY OF TUKWILA AND N FILED HEREWITH, THIS PERMIT IS GRANTED. • 13Y PERMIT NUMBER No 1160 DRESS PHONE VIE OF BUILDER � e � . / G / d/ e ('l. STATE LICENSE NO�1-0 I„ //6, yli SALES TAX NO. DRESS / PHONE !.r i "17`81 . • c,, }` MAR 2S 1976 auu iivu D6■1*, APPLICATION FOR BUILDING PERMIT ESTIMATED VALUE COMPLETED WORK $ / 6/ t D D ------ PERMIT FEE $ 6 L I o v PLAN CHECK FEE $ 361, 0 0 LATE PERMIT _EE To�T FEE $ E(6 40 TYPE OF CONST. N OCCUPANCY GROUP F DATE TODAY FIRE ZONE J USE ZONE C ' \ FIRE SPRINKLERS MAX. OCC. LOAD / 67 IXIYos N No _____REQUIRED :ATION OF WORK / NUMBER & STREET F 6 �5v v 'Pv1 7 P f� NER BLOCK SUBDIVISION < rt�f U ICRIPTION OF WORK; F •I k - SS CITY OF TUKWILA MUM DEPARTMENT 6230 Southcenter Blvd. Tukwila, Washington 98067 Phone: (206) 242 -2177 cR lA JT ' ' THIS PERMIT DOES NOT AUTHORIZE ANY WORK IN ''BLIC RIGHT-OF-WAY OR ON UTILITY EASEMENTS. SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PL MBING, HEATING, VENTILATING OR AIR CONDITIONING. 1 HEREBY CERTIFY THAT NO WORK IS TO BE DONE EXCEPT AS DESCRIBED ABOVE AND IN APPROVED PLANS AND SPECIFICATIONS AND THAT ALL WORK IS TO CONFORM TO TUKWILA CODES AND ORDINANCES. APPLICANT BY FIRE DEPARTMENT CITY of TUKWILA 444 ANDOVER PARK EAST TUKWILA, WASHINGTON 98188 TELEPHONE: (206) 244 -7221 Al 'Pieper. . Building Department City of Tukwila. Dear Al', Re ' : ; 31: Flavors Ice Cream In reviewing the above mentioned project:'' plans, please note the following items.: . Per UFC Sec. 10.113, "At every required exit doorway, and wherever otherwise required to clearly indicate the direction of egress,` an exit sign with letters at least 6' inches high and readily distinguishable shall be main- tained." (rear exit only) Maintain sprinkler protection for all enclosed areas, 3. Fire extinguishers shall be provided per NFPA #10,.as'a, minimum requirement: Please.. include : these comments in' Your 'review of above mentioned project. Yours very:. truly, DG vma Douglas . R. Gibbs' cc :TFD file Fire Inspector 177717 y K . • t .; i s try: Opt iF'11!a Fire Prevention Bureau March 31, 1977 floor plan sections remodel STORE LOCATION! SOUTH CENTER SHOPPING CENTER WASHINGTON Store No . 1386 • STORE SPECIFICATIONS FOR 31 FLAVORS STORES REALTY, INC. I. GENERAL BY :,ESSEE A. Leased premises to comply with all detail, measurements and layout : . shown on Lessee's , plans and further detailed in the followin s �+ 9 p..ci- fications. All interior walls, 1n 1udingOdoor openings, to be installed in exact locations shown. Le se Lessee of any design or construction changE: that may differ from Lessee's prepared drawings. Replace tiles in existing suspended T -bar ceiling with Class "A" 24" 48 tiles. Raise suspended ceiling, in storage and toilet area and replace tiles. Less to furnish 'Glaz'e Ceramic tale (I.iterpace BR VI) £3oor <materl only 'for the `sales area. Lessee to install ceraitiic "file complete wi th stop `set brown rubber has,e. Lessee to f a,r nst "a11 in. s'to ia 'ge area Armstron' Fxrelcin'vtnyl askiestos :£ �5 Casa , Oranae, Imurial Texture, size :::12 ", x 12" x' 1 "8 con lre "te with 4" cove `base; Armstrong #14102 Walnut.; Tile to be 'instal, w' th a]ter . ra+ e :Graining. Toilet room is to hav vi nyl seamle floor ;coverthg; o:f pattern 'similar tco above. Lessor gra -"ts ;permission o'f Lessee''s installation signs as shown. 1 work, mate ials ana- construction detaifl used must cod 1 .�r any go iernig riles' =and `:regu'lat`ion as sit forth Building' and'Heal.th .Oepartmon'ts. cooling system. Relocate return storage room! Lessee to utii i7 .existing 'heating air as shown and raise diffuser in 11. ELECTRICAL BY LESSEE Electrical work shall he furnished and installed under the General Contractor in accordance with all City, State and County Codes and requirements. The Electrical Contractor shall obtain and pay f.. all permits, licenses, and fees rectuired, and shall guarantee all labor and materials for a period of one year from date of cometion of electrical installation. The exact locations of all electrical outlets in floor, slab, walls and ceiling shall be the responsibility of the Electrical Contractor. All outlets shown on plans are listed in numerical order and detailed in same order in the followinc soecifirations. Outlets are listed with Symbol "E" and "EP". Control panels and time clocks to be installed in location indicated on plans. Install new 200 amp service and meter in service corridor. Remove and revamp existing 100 amp service. Electrical outlets numbered and defined as follows: 1 EP Furnish and install Duplex Twistlock receptacle in floor in exact location shown for hook -up of one Model BRT-90 and oneBRT -68 cab 20 amp circuit, 115 volts 3/4 HP. S eparate circuits each unit. Outlet box not to exceed 1-1/2 height above floor. 2 ED Furnish and install in exact floor location shown, one (1) floor receptacle box to accomma' ate separate circuit hook -up of two (2) ice cream cabinets. Receptacle box is to accommodate one ( 20 amp, 110 V -115 V twistlock plug connection for one (1) BRT -90 cabinet, 3/4 HP compressor or separate circuits, and a stub -out with separate circuits pulled through for direct rigid conduit connection to junction box in FPD-5 party cabinet, 1/2 HP, 110V -115V. Rigid conduit connection to be installed at time store is being fixturized. Height of outlet box and stub is not to exceed 1-1/2 above finish floor. 3 EP O^rittec3. EP 5 EP 31 FLAVORS STORE Furnish and install on roof weather proof disconnect for hook -up of walk -in freezer cabinet. Provide 30 amp corn pressor circuit and 30 amp electric defrost circuit, 230 Volts, single phase. Furnish and install electrical flex conduit plus 48" through wall at a height of 24" above floor with circuits nulled through for direct hook -up" of soda fountain motor 4 1/3 U.P. 6 E Furnish and install duplex convenience outlet 110 Volts. Page 2 8 EP 9 EP 11 E 12 E 13 E 7 EP 31 FLAVORS STORE Furnish and install in wall duplex U- ground receptacle for hook -up of two Multimixer Malt Mixing Machines. 1/4 H. P. 110 -112 Volts. Install 24" above floor. Furnish and install in wall duplex tJ- ground receptacle for hook -up of Kelvinator Ice Cream Cabinet. Compressor size 1/4 H.P., 115 Volts. Install 24' above floor. Furnish and install in wall duplex U - ground receptacles for hook -up of hot fudge warmer, 350 Watt. Install 24" above floor. 10 EP Ditto 9 EP above. At a height of 94" above finish floor, and 2" out from corner of wall, furnish and install electrical outlet box of flex conduit with circuits pulled through for direct hook -up of three 8' and one 4' single tube fluor- escent light fixtures. Lighting soffit complete with brackets to receive light fixtures will be furnishes; and installed by Lessee. Electrical contractor is to supply, install and hook up lighting fixtures and tubes. Fix- tures to be controlled at panel. Furnish and install wall outlet and lighting fixture in toilet room. Sw_.tch as indicated. Also furnish and in tall ceiling exhaust fan connected to same switch to cornly with ventilation requirements. Furnish and install ceiling outlet in thilet for hook -up of overhead light fixture. Switch:as indicated. Elec- trical contractor to furnish and install ceiling light fixture. 14 E Furnish andd install ceiling outlets, light fixtures, tubes and lines for hook --up of four tube 4' x 2' flush mounted fluorescent fixtures with prismatic lenses as show-. All fixtures to be controlled on one switch. Reuse existing 4' x 2' flush mounted fixtures. Raise fixtures in storage area and revise switching. 15 E Omitted. 1� E Omitted. 17 E Omitted. 18 E Omitted. 19 EP Omitted. Page 3 20 E 21 E Omitted. 22 F Omitted. 25 E F_Irnish and install in locations shown, electrical stubs with circuits pulled through for hook-up of Lessee's exterior siqns. Signs furnished, installed and hooked by Lessee. Control on time clock. Each sign requires two 20 amp circuits. 23 FP rurnish and install new 200 amp power panel and meter. Service to •b of ample size and capacity to accommodate all loads listed, plus two (2) spares. Reuse existing subpanels and main panel if possible. 24 EP Omitted. Furnish and install in wall at a height of 80" above finish floor, recessed electrical clock outlet. 26 E Furnish and install in wall at a height of 24", outlet bo: only with conduit stubbed out for telephone installation. 27 E, 28 E, 29 E, 30 E, 31 E, 32 E, & 33 E. Tarnish and install duplex convenience outlets, 110 Volts, in locations shown on drawings. III. PLUMBING IMPROVEMENTS BY LESSEE A. Plumbing work will be furnished and installed under the General Contractor in accordance with all City, County, and State Codes and requirements. The Plumbing contractor shall make new con- nections to existing city sewer and obtaZn and pay for all permits, licenses and fees pertaining to complete plumbing installation. The exact locations of all stubs, lines and fixtures, as shown on plans and detailed in specifications, shall be the responsibility of the - 'luMbing C The sidewalks, streets, curbs, etc., should it be recuired to open and excavate same for purposes of installing service or sewer lines, are also the responsibility of the Plumbing Contractor. All to be in accordance with City Require- ments. B. All work and material mu -t comply with all State, City and County Codes and r equirements, including local Health Department. C. Plumbing Contractor to furnish and install pressure regulator and relief valve on main supply line to building to insure maximum water r,ressure to building will not exceed 60 P.S.I. nor be less than 40. 31 FLAVORS STORE Page 4 • 31 FLAVORS STORE D. For purposes of identification and detail, all plumbing outlets and lines have been listed in numerical order and detailed for measurements on floor plan. Further detail listed as follows; 1 P Furnish and install 12 x 12 x 8" enameled cast iron floor sink in exact location indicated on plans with 2" drain line and vent concealed in wall. 2 P Ditto 1P above in exact location indicated, except install recessed, flush mounted. Verify with local Heals Department as to type drain required. 3 P Furnish and install hot water stub, 1/2" line through floor in location 'shown. Install good quality hand shut - off valve and back pressure check valve on stub. Height of stub and valves not to exceed 5" above finish floor. 4 P Ditto 3P above for cold water wi.th hand shut -off and check valve on stub. All not to exceed 5" above finish floor. 5 P Furnish and install in floor hot water stub, 1/2" line for soda fountain supply. Furnish al -1 install good quality hand shut -off valve on stub. Height of stub and valve to be 5" above fi.nisr floor. 5 P Ditto 5P above for cold water. Height of stub and valve to be 5" above finish floor. 7 P Omitted. 8 P Furnish and install complete with trim 24" x 20" cast iron, porcelain lined laundry tray, American Std. type 4P7602 including tray, stand, swing spout mixing faucets, (R4240) and han1 shut -off valves on stubs ahead of the swing spout. 9 P Furnish and install compiete,,12" x 12" stainless steel Wash sink with`hot' and cold water. Include trim. 10 P Omitted.: 11 P Furnish and install 50 gallon electric, 10 year hot water heater complete with all water lines and proper venting. Page