HomeMy WebLinkAboutPermit 1032 - RSR Developers Inc - Chameleon Convention Center - FoundationADDRESS
c /o William Tsao /2367 Eastlake Ave. East, Seattle 98102
PHONE
324 -8780
NAME OF BUILDER
C. A. Strouss & Assoc.
STATE LICENSE NO CASTRA259PO
SALES TAX NO. 600 173 414
ADDRESS
821 Puget Lane, Edmonds WA 98020
PHONE
776 -6728
INSPECTION RECORD
FOOTINGS
BUILDING
PERMIT
VOID IF WORK IS NOT
COMMENCED IN 120 DAYS
October 4, 1976
ESTIMATED VALUE
OF WORK $ 333,750.
FOUNDATION
PERMIT FEE $ 392.00
FRAMING
PLAN CHECK FEE $ 263.55
LATE PERMIT FEE $
TOTAL FEE $ 655.55
TYPE OF
CONST. I
OCCUPANCY
GROUP B -2
DATE ISSUED
February 4, 1977
FIRE 2
ZONE
USE
ZONE M-1
EXPIRATION DAIS
FINAL
FIRE SPRINKLERS
REQUIRED ❑Yes [:1No
MAX. n/a
OCC. LOAD
,
LOCATION OF WORK / NUMBER & STREET
LOT
7000 Southcenter Blvd.
BLOCK
SUBDIVISION
OWNER
RSR Developers, Inc.
DESCRIPTION OF WORK:
CITY OF . UKWI LA BUILDING DEPART ►,LENT
6230 Southcenter Blvd.
Tukwila, Washington 98067
Phone: (206) 242 -2177
Foundation only for Chameleon Convention Center
SUBJECT TO Sec. 302 of the UBC, Paragraph 3.
SUBJECT TO special inspection per Sec. 305, UBC.
CALL FOR INSPECTION
BEFORE WORK IS CONCEALED OR
POURING CONCRETE
PHONE
242-2177
FINAL INSPECTION BEFORE OCCUPANCY
APPLICANT William S. Tsao
BY
BUILDING DIRECTOR
BY
THIS PERMIT DOES NOT AUTHORIZE ANY WORK IN PUBLIC RIGHT-OF-WAY OR ON UTILITY EASEMENTS.
SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, HEATING, VENTILATING OR AIR CONDITIONING.
I HEREBY CERTIFY THAT NO WORK IS TO BE DONE EXCEPT AS DESCRIBED ABOVE AND IN APPROVED PLANS AND
SPECIFICATIONS AND THAT ALL WORK IS TO CONFORM TO TUKWILA CODES AND ORDINANCES.
PERMIT NUMBER
N° 1032
SUBJECT TO COMPLIANCE WITH THE ORDINANCES OF THE CITY OF TUKWILA AND
INFORMATION FILED HEREWITH, THIS PERMIT IS GRANTED.
LOCATION OF WORK / NUMBER & STREET
7 o co 1 -1/4c7
OWNER
LOT (BLOCK
f Lki 7;6-0 6.1 ce-
NAME OF BUILDER
*T vcs
ADDRESS
ADDRESS
Ma.
•
5
SUBDIVISION
PECF.I.VED
CITY OF TUKWILA
DESCRIPTION OF WORK:
MAY 131916
BUILDING DEPT:.
NAME OF TENANT
(ill L k.U.ES‘ foU 1 t'q
•
6230 SOUTHCENTER BLVD.
TUKWILA, WASHINGTON 98183 _
Phone: (206) 242-2177
•
APPLICATON
FOR
BUILDING PERMIT
DATE ISSUED
othio Al) C<1._ qk N L&i U Goav&11% 16-1,411,-A..._ •
NATURE OF BUSINESS :
•-t 1..R OA .//i
-/
c ri?tmA• 1 4' 1 1 0
...wafgaeolettofteeixicbtuulaxwiam4stomeinkezmettez
EXPIRATION DATE .
;APPLICANT /?..S
7
r Ytcz , PHONE 7 (-)
ESTIMATED VALUE
OF
COMPLETED WORK S • ).-) 7 3 6
PERMIT FEE $
'PLAN CHECK FEE
.. •
TYPE OF
CON ST.
FIRE-
ZONE
SALES TAX NO. /2 /72: ( 1 -1 /
PHONE
11 1
LATE PERMIT FEE
TOTAL FEE
STATE LICENSE NO. ei-1,1774.5.5
THIS PERMIT DOES NOT AUTHORIZE ANY WORK IN PUBLIC RIGHT-OF-WAY Of? ON UTILITY EASEMENTS.
. SEPAI?ATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, HEATING, VENTILATING OR AIR COiVDITIONING.
c
G3,3
$
$ s s.
OCCUPANCY
GROUP
USE
ZONE
3 0 .5 (,)
/4 /
FIRE SPRINKLERS MAX.
REQUIRED OYes 2610 OCC. LOAD 4
I HEREBY CERTIFY THAT NO WORK IS TO BE DONE EXCEPT AS DESCRIBED ABOVE AND IN APPROVED PLANS AND
SPECIFICATIONS AND THAT ALL WORK IS-TO CONFORM TO TUKWILA CODES AND ORDINANCES.
MARK
CK
TRUCK .
SIZE
AREA (SQ. IN.)
DATE CAST
^�
DATE BROKEN
AGE AT
TEST
• ETIMATE
TICKET N0.
LBS.
P.S.I.
IX /2-
2.f:7-
/ - /3 - 77/0
- /6 - '
3
, , ., .
a�rl o
_
: ".r) /6
�-
• - 5 /
fix? -
_l()-7.-
?
(V
• 3
ENGINEERING CONSULTATION
CONSTRUCTION SUPERVISION
MATERIAL TESTING
.1't) \I)
PERMIT NUMBER / L /
PROJECT
MAILING r �� /
ADDRESS
TEMP. &
WEATHER
TYPE OF CEMENT -A •
L
CEMENT
PROPORTIONS ❑ Lbs. r Sacks /Cu. Yd.
(Not Certified By P.T. Lab) //
SAMPLING IN ACCORDANC.E WITH
APPLICABLE CODE AND SPEC.?
SAMPLING REPRESENTATIVE
OF POUR PLACEMENT?
MIX PROPORTIONS VERIFIED
BY HATCHING SUPERVISION?
Copies 3 to Foodmakers
to:
1 to Tukwila Bldg. Dept
qs . ,REPORT NUMBER P
PREVIOUS RP'T. NO.
PACIFIC TESTING' LABORATORIES
EXECUTIVE OFFICES
3220.17TH AVENUE WEST P.O. CALL BOX 19125 (206) 282.0666
SEATTLE, WASHINGTON 98119
RADIOGRAPHIC INSPECTION
GEOLOGICAL SURVEYS
SOIL TEST BORINGS
SOIL MECHANICS
ye COMPRESSI T ST ESULTS
"15 5 REPORTED BY t t A II .krE /( -/-3-7( NUMB "'y
f1 LF_ 2 .6 If LOCATION /f/d ZL , �E6�A1E /4' D/'
zAzo AteA; DR F ARCHITECT
'I:J /6.)/ i i 414
L J CONTRACTOR ` <,h,/7 `,_D)f S>""'
MIXING 14/4/
PLANT•�
C'SE AGG FINE AGO
❑ Lbs. I In. Max. ❑ Lbs.
r
; SLUMPS
ENGINEER
DESIGN �.•00 f
STRENGTH f'c
ADMIX. 3 -O
❑ Per Sack ❑ Par_,0„
EST. ` , l
ins. MEAS. AIR • Y %; QUANTITY 6 Cu. Yds.
y
` ALL DETECTED DISCREPANCIES
CORRECT PRIOR TO PLACEMENT?
A � WITNESSED PLACEMENT ACCEPTABLE IN ACCORDANCE
/r WITH PROJECT REQUIREMENTS AND CONDITIONS?
, if64 2, z 79 kip
EMBEDDED ITEMS IN GENERAL /
COMPLIES WITH APPROVED PLAN?
POUR LOCATION & NOTES. 1 / 0 /erh
L != 4 �L
Report Certified by
mld 10/18/78 3 day break
mld 10/23/78 7 daybreak
PT Lab Form 935.1 Roy. 1
A Wnahinnton corporation furnishinn nnninrerinn cervices by rind under the sirnrrvicinn of ienieternrt nrnfneeinnnt ennineere C79
1032