Loading...
HomeMy WebLinkAboutPermit 1079 - The Colonial - Tenant ImprovementADDRESS 2 Three Tree Point Lane, Seattle 98166 PHONE 243 -8340 242 -7007 NAME OF BUILDER STATE LICENSE NO. SALES TAX NO. ADDRESS PHONE INSPECTION RECORD FOOTINGS BUILDING PERMIT VOID IF WORK IS NOT COMMENCED IN 120 DAYS December 17, 1976 ESTIMATED VALUE OF COMPLETED WORK $ 350,000.00 FOUNDATION PERMIT FEE $ 512.00 FRAMING PLAN CHECK FEE $ 332.80 LATE PERMIT FEE $ TOTAL FEE $ 844.80 TYPE OF CONST. V 1 HR OCCUPANCY GROUP F-2 DATE ISSUED April 17, 1977 ZONE 3 C -2 ZONE EXPIRATION DATE FINAL FIRE SPRINKLERS REQUIRED MAX. OCC. LOAD 246 P(Yes II No LOCATION OF WORK / NUMBER & STREET LOT OWNER BLOCK DESCRIPTION OF WORK: SUBDIVISION CALL FOR INSPECTION BEFORE WORK IS CONCEALED OR POURING CONCRETE PHONE 242-2177 FINAL INSPECTION BEFORE OCCUPANCY CITY Ori UKWILA BUILDING DEPART( :NT 6230 Southcenter Blvd. t542A 5301 Southcenter Blvd. Mr. & Mrs. Richard Hall Retail clothing store. The Colonial Tukwila, Washington 98067 Phone: (206) 242 -2177 THIS PERMIT DOES NOT AUTHORIZE ANY WORK IN PUBLIC RIGHT-OF-WAY OR ON UTILITY EASEMENTS. SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, HEATING, VENTILATING OR AIR CONDITIONING. PERMIT NUMBER N_ I HEREBY CERTIFY THAT NO WORK IS TO BE DONE EXCEPT AS DESCRIBED ABOVE AND IN APPROVED PLANS AND SPECIFICATIONS AND THAT ALL WORK IS TO CONFORM TO TUKWILA CODES AND ORDINANCES. APPLICANT Mr. /Mrs. Richard Hall BY SUBJECT TO COMPLIANCE WITH THE ORDINANCES OF THE CITY OF TUKWILA AND INFORMATION FILED HEREWITH, THIS PERMIT IS GRANTED. BUILDING DIRECTOR BY ADDRESS Z / fr7/ G - 7 _ E w«...wwa rt=b /4./'T G A'-r 6 SC'"�7 ipIG4 r PHONE C,/.." 3 a3 (.1. . C' z - 70 4 ' 00WIwe NAME OF BUILDER STATE LICENSE NO. SALES TAX NO. ADDRESS PHONE I ; �Y )I 1 Y ; CITY , , • _ / I . - (� 2 . OF TUKWILA 1975 t` `? 9 r # i : .,: . ; ^ 5 ).1 I �� �LB��'� ®�� FOR BUILDING PERMIT • ESTIMATED VALUE '� COOMPLETED WORK $ G- 000 C) ✓ - MIT FEE P;� ab l 76 _/ 1 ,`� t 'PLAN CHECK FE a__._ . 33:2. x. ;�'r t. 4 a 339 $ 3/.27//5— LATE PERMIT FEE TOTAL FE $ TYPE OF i CONST. OCCUPANCY .— Z GROUP / DAIE ISSUED I FIRE I ZONE USE ZONE L— 2 • EXPIRATION DAM FIRE SPRINK S REQUIRED Yy o MAX. OCC. LOAD LOCATION OF WORK / NUMBER Be STREET �O / LOT 0 6i.C6 Stl OWNER f .11•2 0 _ BLOCK SUBDIVISION 9 P L!WL1E RW D E VART 6230 Southcenter Blvd. Tukwila, Washington 96067 Phone: 242 -2177 S C /3 G VI) /4/2 Ai/(7_ S (2/ cA'4 /0' /7/ 4 LL S 'TO /26; ,gc11 cp/ APPLICANT Name of Tenant: Co _O. //,4 L Nature of Business: G 4c.)7 //4../C /2 e f/a /L ,did Gam' THIS PERMIT DOES NOT AUTHORIZE ANY WORK IN PUBLIC RIGHT-OF-WAY OR ON UTILITY EASEMENTS. SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, HEATING, VENTILATING OR AIR CONDITIONING. I HEREBY CERTIFY THAT NO WORK IS TO BE DONE EXCEPT AS DESCRIBED ABOVE AND IN APPROVED PLANS AND SPECIFICATIONS AND THAT ALL WORK IS TO CONFORM TO TUKWILA CODES AND ORDINANCES. fr/ /2 4'4// S /-7' 4 Le.-. • CALHOUN W HI CONSTRUCTION CO., INC. i ill I I I llill VIII II' 718 SOUTH CENTRAL AVENUE • UL. 2 -6360 • KENT, WASH. 9 December 2, 1976 City of Tukwila 6230 Southcenter Blvd. Tukwila, Washington 98188 Attention: Alfred J. Pieper, Building Inspector Re: Building Permit for "THE COLONIAL" Sincerely yours, CALHOUN CONSTRUCTION CO.., INC. .6)( )47. Willis M. Calhoun President Dear Sir: We are progressing with the sitework and foundation forms per our discussion a couple of weeks ago. We hope you have had the time to review the old plans and documents as we discussed and will be able to issue the permit soon. We expect to be ready for our first concrete pour by approximately December 15, 1976. If there are any items we can help with please feel free to contact our project superintendent at the jobsite (244 -8862) or our Kent office (852- 6360). cc: Alexander G. Sasonoff - • . 4 - 0 1 : 4 1 4 . 4 1 , 1 11 AI( EA UtaL n stt) -5pt a ( 1z_64 r) k p oC, T2 L L. o ‘4b`Si4 K444cm ; Forte M a.Tegi s:1) .r1 L ' 512 S A (1 O N O F F & M C K L E N B U R fr 1 2 .,. 1975 ? Tq.9::W 'a Bernard L. Ruppert, Building Director Public Works Department 6230 Southcenter Blvd Tukwila, Wash. 98067 Dear Mr. Ruppert: Re: "The Colonial" Corrections made to drawings and specifications per your letter dated Sept. 4, 1975. Basement: 1. Two exits will be provided. Stair No. 2 has been extended to basement and required exit signs provided. Sheet E3„ 2. Corridor serving as exit will be made to comply with 1 hour code requirement. 3. Directional exit signs have been added. See Sheet E3 4. Counter opening is automatic fire door controlled by a fusible link. See Section 8D Specifications. Main Entrance Door has been moved to comply with separation. Sheet A4. Directional exit signs have been added. Sheet E4. Upper Floor: 7. Exit signs have been provided. Sheet E5. 8. Stairway No. 2 has been widened. 9. Automatic sprinkler system will be installed in building on all 3 floors. Shop drawings will be submitted at a later date for Bldg. Dept. approval. 10. Main roof drainage is shown on Upper Floor Plan, Sheet M -4. Scuppers are shown on elevation drawings of Architectural Dwgs. 11. Mens Toilet in Basement has been made to comply for handicapped and Toilet for Women on Main Floor has been made to comply. Main Floor: General Sept. 17, 1975 A I I C H I T E C T S 2 2 0 1 S W 1 5 2 N U 2 4 2 • 3 7 3 5 rw+ommese wmr.. SE A T T L E, W A S H 1 N G T G N 9 8 1 6 6 . Bes .regards, 12.. Hose stations will be provided per Ordinance #730. 13.. Mechanical heating and air conditioning system provides air changes per Code requirements. General: PUBLIC WORKS DEPARTMENT 6230 Southcenter Boulevard Tukwila, Washington 98067 telephone C 206 ) 242 - 2177 September 4, 1975 Mr. Alexander G. Sasonoff Q 2201 S. W. 152nd St. Seattle, Washington Re: "The Colonial" MO N he CC requirements other than structural: 4( Q, Basement: Dear Mr. Sasonoff: Following are comments relative to Uniform Building Code '1. Two exits are required, Sec. 3302(a). N2. Corridor.se exit from floor above and is required to be one -hour fire resistive with rated, self - closing doors (Sec. 3304). '3. Directional•exi.t signs required, Sec. 3312(a). 4. ,Counter opening to be fire protected. Main Floor: 5. Exits not properly separated, Sec. 3302(c). 6. Directional exit signs required. Bernard L. Ruppert Building Director Upper Floor: 7. Exit signs..r 48. Width of stairway #2 will prevent ever using this for retail sales purposes. 9 . Automatic fire sprinklers requir. 3802(b)1. -10. Please show drainage for . main_ roof, area. Also, overflow scuppers required, Sec. 3207(c). ..t.11. 'Provide facilities for handicapped Sec. 1711. 12.• Hose stations required per, Tukwila Ordinance #730 (copy enclosed). 13. Provide two changes of air per hour (Sec. 1105). Comments on the structural review as well as those of the Public Works Department, Planning Department and Fire Department will be forwarded as they are received. el r' 2 (cm/ W W Sincerely yo W BLR /ma cc: Fire Department CATION OF WORK / NUMBER & STREET IT ■•■••74 VNER )DRESS veorovowoomi.poore4. %ME OF BUILDER )DRESS ESCRIPTION OF WORK: ••■■•••••••"....,••■•••■•••••• Nature of Business: ■■•••••■■••• .,•••••':.--;•!;;;.•.•:::-.., • BLOCK Aldo [TV vE [VI NU IING REVIERtENT /-( 0 '— SUBDIVISION CITY OF TUKWILA CP/ 6230 Southcenter Blvd. Tukwila, Washington 98067 Phone: (206) 242-2177 A-222 S 2/ C / 4 /co /-/ 4 LL — 7 - 7-icf: 6 e A A./ 6 I APPLICATION FOR BUILDING PERMIT . DALE ISSUED EXPIRATION DALE Name of 'Tenant: C(..)Z.-0,,V/A S 'TO 12 /gCli_ CD/ // a 7`;‘./ /2 7 lc_ 3- , — j.-e , 5 `P/cei F' 3 • C,/ . • - .44 STATE PHONE ESTIMATED VALUE ; OF: COMPLETED WORK $ Z?2 • COO PERMIT FEE LiceNsti NO. • TOTAL FE TYPE OF CONST. FIRE ZONE FIRE SPRINK REQUIRED SALES TAX NO. •PL N CHECK FEE LATE PERMIT FEE 0 THIS PERMIT DOES NOT AUTHORIZE ANY WORK IN PUBLIC RIGHT-OF-WAY OR ON UTILITY EASEMENTS. SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, HEATING, VENTILATING OR AIR CONDITIONING. s-- N OCCUPANCY -z GROUP USE ZONE 1 / 4 - - MAX. OCC. LOAD 10 •■•••••• I APPLICANT / / 1(4"/6 ° S 4 Z:C !IA I HEREBY CERTIFY THAT NO WORK IS TO BE DONE EXCEPT AS DESCRIBED ABOVE AND IN APPROVED PLANS AND , SPECIFICATIONS AND THAT ALL WORK IS TO CONFORM TO TUKWILA CODES AND ORDINANCES. ui�.•r 4 -c" H1I,14 c0.404 (j L str -5pec -I to • r t7-6 n k F3 z i,l.;i E. Col j5t. -C --f -to ¶ . t ea L . o 5e 5u p: -t * o \ i4y xG;4 i4 Foil e >'j. A'TZ.iGL) th 2 0 J I- General: W W a w 2 a W w 2 2 W PUBLIC WORKS OEPARTME 'T 8230 Southcenter Boulevard Tukwila, Washington 98067 telephone t 206 3 242 — 2177 September 4, 1975 e Mr. Alexander G. Sasonoff 2201 S. W. 152nd St. Seattle, Washington m Re: The Colonial" E Dear Mr. Sasonoff: x Following are comments relative to Uniform Building Code a requirements other than structural: 4( 0, Basement: 1. Two exits are required, Sec. 3302(a). i 2. Corridor serves as exit from floor above and W is required to be one -hour fire resistive . with rated, self - closing doors (Sec. 3304). 3 3. Directional exit signs required, Sec. 3312(a). w 4. Counter opening to be fire protected. 0) Main Floor: 5. Exits not properly separated, Sec. 3302(c). W 6: Directional exit signs required. F' Upper Floor: 7. Exit signs required. 8. Width of stairway #2 will prevent ever using N this area for retail sales purposes. 9. Automatic fire sprinklers required, Sec. 3802(b)1. 10. Please show drainage for main roof area. Also, overflow scuppers required, Sec. 3207(c). 11. Provide facilities for handicapped, Sec. 1711. 12. Hose stations required per Tukwila Ordinance #730 (copy enclosed). 13. Provide two changes of air per hour (Sec. 1105). Comments on the structural review as well as those of the Public Works Department, Planning Department and Fire Department will be forwarded as they are received. cc: Fire Department Sincerely yo 4 Bernard L. Ruppert Building Director D S A S O N O F F E, M Bernard L. Rupert, Building. Director Public Works Department 6230 Southcenter Blvd Tukwila, Wash. 98067 A Dear Mr. Rupert: Re: "The Colonia We are experiencing a delay in arranging financing for the Colonial and would appreciate your holding our application for permit in abeyance. We hope to have the details worked out in the near future so we can proceed. Hopefully this will not inconvenience you or your office. Please call me if you have any questions. gards E N B U R G A Q C H 1 T E C T S AGS:ht Jan 7, 1976 . Alexander G. Sasonoff, A.I. GC /cw MEMOERAf\IDUM MTV' TUK VQLA OFFICE of COMMUNITY DEVELOPMENT 2 December 1976 TO: Dick Williams FROM: Gary Crutchfield SUBJECT: VARIANCES for Colonial House Development VARIANCE from setback of parking surface edge: Hope this clears the air for you. The Colonial House Development, to be located at Southcenter Boulevard and 53rd Avenue, was granted two 12) variances in early 1974. 1. VARIANCE from 60' R/W width: 0 ,Su.. 415 1,64' LI Y W b d dk Due to length of 53rd Avenue, St wanted50' R/W with 80' (diameter) ,4 cul -de -sac. Planning Commission, in rezoning parcel lying west of 53rd Avenue, obtained agreement to provide 10' additional R/W along west side of 53rd, hence gaining 50' total R/W when it develops. Based on this assurance of 50' R /W, Commission granted variance from 60' R/W requirement with the stipulation that a Developer's Agreement be executed between Colonial and City to establish street development requirements as Steve sees fit. /444.- 41t,L ev. be closer to edge This one is simple enough -- allows parking stalls of road than required by code — no conditions. Both variances were granted in January 1974. A variance becomes void after one (1) year if a permit for the variance - approved plans is mot obtained within that year. To the best of my knowledge, no permit has been issued since either variance was granted; HENCE, neither variance. is valid. Dick Williams City Of Tukwila 6230 Southcenter Tukwila Wash. IJ R G A R C H I T E C T S RE: Colonial Bldg. 15424 53rd So. Dear Mr. W i l l i a m s We. will submit curb grade drawings to you for your approval within 45 days. These.grades wil establish the new street grade for you along 53rd So.: E; 2 Y 0,• 1 5 W.: 1 , . 5. .,2 N D 2:_ A 2 3 7 • 3 .5 ,s #40.4. ns wr }+memo mu�ub�i.a urbscros m .rx �+awlocive atilkel ea, C S ;A T T I F _ W A .0 /1 I• u .�:' A I AA Mr. Barney Ruppert Building Department City of Tukwila Dear Barney: JH:vma cc:TFD file FIRE DEPARTMENT CITY of TUKWILA 444 ANDOVER PARK EAST TUKWILA, WASHINGTON 98188 TELEPHONE: (206) 244 -7221 In reviewing the above mentioned project plans, please note the following items: 1. Per UFC Sec. 10.104(b), "All doors in or lead- ing to exits shall be maintained openable from the inside without the use of a key or any special knowledge or effort at all times when the building or area served thereby is occupied ". 2. Walls are to be fire stopped per UBC Sec. 2517(f). 3. All sprinkler drawings shall be prepared by reputable companies licensed to perform this type of work. Drawings shall first be approved by the Washington Survey & Rating Bureau, then by the Tukwila Fire Dept. No work shall commence without approved drawings. 4. Fire extinguisher type, quantity and placement shall;. be per. NFPA #10. 5. Protective guard posts or curbs are required around all gas meters, electrical vaults, sprinkler valves;, and hydrants. • 6. Exits must be illuminated at all times that the building is occupied per U.F.C. Section 10.113. This requires a stand -by electrical system for emergency use. Please include these comments in your review of the above mentioned project. Fire Prevention Bureau September 26, 1975 Re: The Colonial Yours very truly, James A. Hoel Fire Marshal September 17, 1975 City of Tukwila Department of Public Works 6230 Southcenter Boulevard Tukwila, WA 98067 Attention: Bernard Ruppert, Building Director Re: Plan Review No. 75 -S -9 Gentlemen: B. RICHAL SMITH GARY M. SWENSON 002 COLMAN BUILDING SEATTLE, WASHINGTON 98104 Tusr=oN (206) 024 -8160 We have received the proposed Colonial. Building and have reviewed it in compliance with chapters 23 through 29 of the Uniform Building Code. Here are our comments: 1. Provide Span Deck shop drawings. 2. Storage areas require 125 PSF minimum live load. Please call if you have any questions. Sincerely, S E P 22 1975 CITY OF TUKWILA PuBLL.IL. WORK.% ,CIEPARTMIC J` r 8230 Bouthcenter Boulevard Tukwila, Washington 98067 telephone t 206 ) 242 — 2177 September 11, 1975 th 0 J Mr. Alexander G. Sasonoff Ei 2201 S. W. 152nd St.. Seattle, Washington m th Dear Mr. Sasonoff: Et a W it W OD W N W E . H 2 CC tU 2 2 Re: Plan Review The Public Works Department has reviewed your plans for the proposed "Colonial ". We find that your site and utilities plans do not contain enough information to warrant approval. Please provide additional information regarding type of pipe for storm sewer, sanitary sewer and water lines, percent of slope on the appropriate sewers, backflow prevention device locations, type and size and radii on curb cuts. If we can be of any assistance in these matters or answer any questions, please do not hesitate to call us at 242-2177 between 8:30 A.M. and 5:00 P.M. Sincerely yours, lnJ 1 // /' Richard K. Williams Engineering .Technician City of Tukwila Department of Public Works 6230 Southcenter Boulevard Tukwila, Washington 98067 ROBERT VALLA & ASSOCIATES CONSULTING ENGINEERS SUITE #730 FOURTH & PIKE BLDG. SEATTLE, WASHINGTON 98101 November 8, 1 975 Attention: Bernard Ruppert, Building Director Re :. Plan Review No. 75 -S -9 Dear Sir: The sdtorage area in question is a temporary storage area where dresses on racks with walk space between will be stored for a short period of time. The live Load during that period will be less than 75 PSF, but, will be 75PSF when the area is used for retail sales. TELEPHONE 624.5451 248 -1438 522 -4816 13: RIC)Li L SAIITII cSt ASSOCIATES CONSULTLNG ENGINEERS September 17, 1975 City of Tukwila,."' Department ,of Public Works 6230 Southcenter Boulevard Tukwila, WA 98067 Attention: Bernard Ruppert, Building Director Re: Plan Review No. 75 -S-9 Sincerely, /f B. Richal Smith, P,E., . Structural Engineer TP:mw We have received the' proposed.Colonial Building and have reviewed it incompliance with chapters 23 through 29 of the Building Code. Here are our comments: 1. Provide Span Deck shop drawings.' -ti ( 2torage areas require 125 PSF minimum live.load. SEP 2 ; 1975 Please call if you have any questions.' 13. RICSAL S'JIITIH .' GARY M. 8WENSON 002 coLues BI TIDING SEATTLE. WASEUNGTON 08104 TzLzrzto1 z (208) 624 -8150 C• M r Robert Valla"& Associates Consulting Engineers Suite #730 , Fourth '& Pike Bldg Seattle Wa • 98101 In regard to your letter 1of' September 28th; con- cerning. the:. use of our ". top= floor . "storage area "; your assumption is absolutely,: correct: The, area planned as. a future.' sales =i.area' anise as zstorage .. will- be`.temporaT a nti ` 'tconsist�t�:•o } i i.:.. u .• y F .? t , . ✓ :; t xri >. ), c ai't.lair. '. : .w i %� th' isle. space. 1..,: ,$] «<. �;,. -Y,. ,,:` "" h , : ' r , ! .. Z C° . 3� d �; �i�rt :.�i:.'... Dear Mr Valla: 1! S eptember4 *00 SP. ij 452nd 9eale4, �'aslu.'s�ij4 n 98166 ?DAY s 42444 7104 B. RICSAL SMITH &. ASSOCIATES • cioNstrinNG.ENGINEERB November 12, 1975 City of Tukwila .Department of Public Works -6230`Southcenter Boulevard Tukwila, WA 98067 Attention: Bernard Ruppert, Re: Plan Review No. 75 -S -9 Gentlemen: Please call if you have any questions. '_Sincerely Building Director B. MORAL OMIT$ GARY M. SWENSON 802 DOLMAN BUILDING SEATTLE, WASHINGTON 08104 TILXPEOW (208) 824.8150 We.have received a letter of revision for the Colonial and all of our questions have been'answered'satisfactorily. However; it is:still nec- essary to 'provide span deck shop drawings. B. MORAL Sm.= & ASSOCIATES CONSULTING ENGINEERS November 12, 1975 City of Tukwila • Department of Public Works 6230 Southcenter Boulevard Tukwila, WA 98067. Attention: Bernard Ruppert, Building Director Re: Plan Review No. 75 -S -9 Gentlemen: We have received a letter of revision for the Colonial and all, of our questions have beein•answered satisfactorily. However, it is still nec- essary to provide span deck•shop drawings. Please call if you have any questions. Sincerely B. Richal Smith, P.E. Structural Engineer • B. RICIIAL SMITH GARY 11I. SWENSON 602 COLMAN BUILDING SEATTLE. WASHINGTON 08104 TELEr80H11 (200) 024 -8150