Loading...
HomeMy WebLinkAboutPermit D05-002 - INSURANCE AUTO AUCTION - DIESEL FUEL TANKINSURANCE AUTO AUCTION 8801 E. MARGINAL wys. D05 -002 t t 7 i 10 .0 o DEVELOPMENT PERMIT Parcel No.: 5422600060 Address: 8801 EAST MARGINAL WY S TUKW Suite No: Type of Construction: Tenant: Public Works Activities: Name: INSURANCE AUTO AUCTION Address: 8801 EAST MARGINAL WY S, TUKWILA WA Owner: N Name: KENWORTH MOTOR CORP Address: i 8801 E MARGINAL WAY, SEATTLE WA Contact Person: N Name: DAVID KEHLE Address: 12720 GATEWAY DR, STE 116, TUKWILA WA Contractor: N Name: SGA CORPORATION Address: 1501 N 200 ST, SHORELINE WA Contractor License No: SGACO * *084BS Permit Number: Issue Date: Permit Expires On: Phone: Steve Lancaster, Director D05 -002 01/21/2005 07/20/2005 Phone: 206 433 -8997 Phone: 206 778 -2191 Expiration Date: 01 /10/2006 DESCRIPTION OF WORK: INSTALLATION OF 500 GALLON DIESEL FUEL TANK WITHIN A PLASTIC CONTAINMENT TUB AND WITHIN A CONCRETE ! PROTECTION /CONTAINMENT AREA. TANK IS ABOVE GROUND WITH UL LISTING AND DISPENSER. Value of Construction: $2,000.00 Type of Fire Protection: SPRINKLERS Type of Construction: II -B Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Flood Control Zone: N Hauling: N Land Altering: N Landscape Irrigation: N Moving Oversize Load: N Sanitary Side Sewer: N Sewer Main Extension: N Storm Drainage: N Street Use: N Water Main Extension: N Water Meter: N Fees Collected: $145.91 International Building Code Edition: 2003 Occupancy per IBC: 0025 Number: 0 Size (Inches): 0 Start Time: End Time: Volumes: Cut 0 c.y. Fill 0 c.y. Start Time: End Time: Private: Public: Profit: N Non - Profit: N Private: Public: doc: IBC-Permit D05 -002 Printed: 01 -21 -2005 C � f ti � i� ity G1 Tukwila Steven M. Mullet, Mayor Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: ci.tttkwilama.its s Z u�= J U" UO Co o W X. J � LL: W O. L L �a t W Z � O`. Z i-- Au5 O —: W W; H V;. ed Z Z City u Tukwila ' Steven M. Mullet, Mayor Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: ciaukwila.wa.us Permit Number: Issue Date: Permit Expires On: Steve Lancaster, Director D05 -002 01/21/2005 07/20/2005 Permit Center Authorized Signature: Date: l ��` �•=�� ok I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating constr ction or the performance of work. I am authorized to sign and obtain this development permit. Signature: I Date: - fly Print Name: 0"ad - T This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. f f I r i 1 i doc:IBC- Permit D05 -002 Printed: 01 -21 -2005 -a 9 e Cit y of Tukwila f�Q Department of Community Development / 6300 Southcenfer BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 PERMIT CONDITIONS Z Parcel No.: 5422600060 Permit Number DOS -002 W W Address: 8801 EAST MARGINAL WY S TUKW Status: ISSUED Suite No: Applied Date: 01/04/2005 v O Tenant: INSURANCE AUTO AUCTION Issue Date: 01/21/2005 Cl) ❑ C0 W J = H 1: ** *FIRE DEPARTMENT CONDITIONS * ** CO) U. W 2: Approved portable fire extinguisher complying with Section 906 with a minimum rating of 2A, 20B:C shall be provided and Ua located such that an extinguisher is not more than 75 feet from pumps or storage i s. a tank fill-pipe openings. IFC 2205.5 9 P P 9 pp p 9( ) U_ < � 3: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or H w brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation z instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so z 0 that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross w weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the o 2 floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 v N inches (102 mm). (IFC 906.7 and IFC 906.9) o 4: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot W —. v be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) w Z 5: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available v co for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) Z 6: ** *HAZARDOUS CONDITIONS * ** 7: Installation and use of "fleet vehicle motor dispensing facility" shall meet all applicable Sections of the IFC chapter 22, 27, and 34. 8: Hazardous materials shall not be released into a sewer, storm drain, ditch, drainage canal, lake, river or tidal waterway, or upon the ground, sidewalk, street, highway or into the atmosphere. (IFC 2703.3) 9: Visible hazard identification signs shall be placed at entrances to locations where hazardous materials are stored, dispensed, used or handled in quantities requiring a permit. Individual containers, cartons or packages shall be conspicuously marked or labeled in accordance with nationally recognized standards. (IFC 2703.5) (NFPA 704)) 10: The tank shall be seismically anchored (IFC 2703.2.8) 11: "No Smoking" signs shall be conspicuously posted within and at all entrances to hazardous materials storage areas. (IFC 2703.7.1(1 -4)) 12: Tanks containing classl, 2 and 3A liquids shall have emergency venting. (IFC 3404.2.7.4) 13: Vent pipe outlets for tanks storing Classl, 2 or 3A liquids shall be located such that the vapors are released at a safe point outside of buildings and not less than 12 feet above the adjacent ground. (IFC 3404.2.7.3.3) 14: An operational permit is required for the use, storage or handling of flammable or combustible liquids. (IFC 105.6.17, Chapter 34) doc: Conditions D05 -002 Printed: 01 -21 -2005 i i City of Tukwila We Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 doc: Conditions D05 -002 Printed: 01 -21 -2005 I �l1Ul K -`� •" i City of Tukwila f9C6 I 1 l Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 { i t i I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws + regulating construction or the performance of work. I Date: / - '=�- / - n: doc: Conditions D05 -002 Printed: 01 -21 -2005 mo w' CITY OF TUKWIL. t Community Development Department Public Works Department Permit Center * taoe 8300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 Building Permit No. Mechanical Permit No. Public Works Permit No. Project No. (For ooke use only) Applications and plans must be complete in order to be accepted for lan review. Applications wil not be accepted through th mail r by(Lax) * *Please Print ** 'WXIMATION King Co Ai g or's Tax No.: Site Address• SSuite umber: Floor: Tenant Name: k m I L -- rlo New Tenant: l Tenant: ...... Yes �.. No Property Owners Name: V IH HOLV H&I Cv, Mailing Address UNual. '�i� / ►. / V City State Zip Name: " VIW 'C/t✓FIIN DavTelenhone: M0 IT7:/I Mailing Address U- I GU L-V I t7ir-x.1 ( r'W. ✓it l j G I rt!/ E -Mail Address: Jk&WCJ dkeh6e&M, , &0A City 9& State Zip Fax Number: GENERAL CONTRACTOR INFORMATION: - (Mechaaicai,Coutructor ieformation on buck page) Company Name: Mailing Address City State Zip Contact Person: Day Telephone: E -Mail Address Fax Number: Contractor Registration Number. Expiration Date: * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** ARCHITECT OF RECORD = ARpplaes niust be wet stamped by ArAitect`of Record:: Company Name:_ Mailing Address; Contact Person: W 4 V 0 E E -Mail Address- t'7t ` �� Q City state zip Day Telephone: �_ "f� Fax Number: l' -JI 'b ` s' ;ENGINEER OF RECORD All plans, must be wet stamped by Engineer of Record Company Name: Mailing Address i City State Zip Contact Person Day Telephone: E -Mail Address Fax Number: i %aMkatiors pvmit apptieation (7.2004) Pace 1 &%V" OK 4 Z iH W lY � UO to a W= F to LL WO J U- 0 . W �5 U� ON o�- WW U 0 itl Z co Z~ 'BUIL DING PERMT- INFORK -Y'ION =206,4 14670 Valuation of Project (contractor's bid price): Mp 1 co Existing Valuation: $ 2 M ( WIo Will there be new rack storage? [:]..Yes X If "yes", see Handout No. for requirements. Provide All Building Areas in Square Footage Below PLANNING DIVISION• Single-family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) � -_ r *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: c Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: N Compact: Handicap: Will there be a change in use? ❑..... Yes 16-No If "yes", explain: FIRE PROTECTIONIH ZA U MATERIALS: ...Sprinklers 0-Automatic Fire Alarm ❑ ... ❑ ... Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ ... Yes ❑ ...No If "yes ", attach list of materials and storage locations on a separate 8 -111 x II paper indicating quantities and Material Safety Data Sheets. NaMicuioWr=mlt aWicsibn (7.2004) Paae 2 Z Z: �a 2 W D J U U O U � W W J � LL W U. Q N d = W Z t— O Z 1— W �j UC O N` � 1— WW t=-- H L O. LLI Z U =, O Z Existin Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1 Floor Floor 37 Floor Floors thru Basement. Accessory Structure' Attached Garage Detached Garage Attached Carport Detached.Carport . Covered Deck Uncovered Deck PLANNING DIVISION• Single-family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) � -_ r *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: c Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: N Compact: Handicap: Will there be a change in use? ❑..... Yes 16-No If "yes", explain: FIRE PROTECTIONIH ZA U MATERIALS: ...Sprinklers 0-Automatic Fire Alarm ❑ ... ❑ ... Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ ... Yes ❑ ...No If "yes ", attach list of materials and storage locations on a separate 8 -111 x II paper indicating quantities and Material Safety Data Sheets. NaMicuioWr=mlt aWicsibn (7.2004) Paae 2 Z Z: �a 2 W D J U U O U � W W J � LL W U. Q N d = W Z t— O Z 1— W �j UC O N` � 1— WW t=-- H L O. LLI Z U =, O Z 1 I` PUBLIC WORKS PERMIT INFORMA'�fION 3 6433-0179,, :. Scope of Work (please provide detailed information):___.�`Jul Call before you Dig: 1-860424-5555 Please refer to Public Works Bulletin #1 for fees moil estimate sheet. Water District ❑ ... Tukwila ❑ ... Water District #125 ❑...Highline ❑...Renton ❑ ... Water Availability Provided Sewer Diatrlct ❑ ... Tukwila ❑ ... Va1Vue ❑ ... Renton ❑ ... Seattle H Sewer Use Certificate ❑ ... Sewer Availability Provided [I ... Approved Septic Plans Provided ... Septic System- For oasite septic system, provide 2 copies of a current septic design approval by King County Health Department. Submitted with A011catio (mark boxes which Ugly): ❑...Civil Plans (Maximum Paper Sbx -22" x 34") ❑ ... Technical Infirmation Report (Storm Drainage) ❑ ... Geotechnical Report ❑ ...Traffic Impact Analysis []...Bond ❑ ... Insurance ❑ ...Easement(s) ❑... MaintenanceAgreement(s) ❑ ...Hold Harmless ProggW Activities (mark boxes that anDlv): ❑ ... Right-of-way Use - Nonprofit for less than 72 hours ❑... Right-of-way Use - Profit for less than 72 hours ❑ ... Right -of -way Use - No Disturbance ❑ ... Right -of -way Use —Potential Disturbance ❑...Constmction/Excavation/FilI - Right-of-way Non Right -of -way ❑...Total Cut cubic yards ❑ ... Work :n Flood Zone ❑ ... Total FRI cubic yards ❑ ... Storm Drainage ❑ ... Sanitary Side Sewer ❑ ...Abandon Septic Tank ❑ ...Grease Interceptor ❑ ... Cap or Remove Utilities ❑ ...Curb Cut ❑ ...Channelization ❑ ... Frontage Improvements ❑ ...Pavement Cut ❑ ...Trench Excavation ❑ ...Traffic Control ❑ ...Looped Fire Line ❑ ...Utility Undergrounding ❑ ... Backflow Prevention - Fire Protection " Irrigation " Domestic Water ❑... Permanent Water Meter Size... I I WO# ❑... Temporary Water Meter Size.. WO# ❑ ... Water Only Meter Size............ WO# ❑ ...Deduct Water Meter Size......... " ❑ ... Sewer Main Extension ............. Public Private ❑ ... Water Main Extension ............. Public Private FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ ... Water ❑ ...Sewer ❑ ... Sewage Treatment Monthly Service Billing to Name Day Telephone Mailing Address City state Zip Water Meter Meter Reimd/Bill' Name _ Day Telephone Mailing Address v City State Zip \aWi -don *mt1tapplicationt7 -2004) Pave 3 Z J.-Z !Y W W� J U 0 CO) W = Ji. CO) W W O 2 LL Q N d = W Z !•-., l- O Z 1-- w UJ � o' O N, J3 H- W UJ U. O lii Z: O ~. Z MECHANICAL PERMIT INFORMATION = 206- 431 - 3670 MECHANICAL CONTRACT IN RMATION Company Name : TT4t5 Mailing Address City State Zip Contact Person: Day Telephone: E -Mail Address Fax Number. Contractor Registration Number: Expiration Date: * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** Valuation of Project (contractor's bid price): $a Scope of Work (please provide detailed information): JL% Residential: New .....0 Replacement .....❑ Commercial: New .....0 Replacement .....❑ Fuel LM : Electric ......0 Gas ..... 0 Other. Indicate type of mechanical work being installed and the quantity below: Unit Type: Oty Unit Type: Qty Unit Type: Boiler/Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0-3 HP /100,000 BTU Furnace >100K BTU EvaporatorCooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30-50 HP /1,750,000 BTU Appliance Vent Hood Water Heater 50 +HP /1,750,000 BTU Heat/Refrig/Cooling System Incinerator - Domestic Emergency Generator Air Handling Unit <10,000 CFM Incinerator — CommlInd Other Mechanical Equipment PERIVIIT APPLICATION' NOTES Applicable twall permits in this Application Z �W _3 U UO to 0 .J = H CO LL W O 9-1 LL Q to 0 = F. W Z� F_ O Z I_ UJ 5 U O N 0 H WW �U U_ O t! t Z co O Z Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF. UQY BY THELAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Print Mailing City Date: ��31,0 State Zip Date Application Accepted: Date Application Expires: Staff Initials: 1-41-19 7- 1 159S *v6atiom. =mltappliagioa(7 -2004) Paee 4 - 'l l 1 1 1 I �� i i 1 City of Tuk wila Fire Department TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Steven M. Mullet, Mayor Thomas P. Keefe, Fire Chief Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206 -575 -4404 • Fax: 206 -575 -4439 z a '~ w J U. U UU CO) LU J = H NU_ wO �Q UD = �w Z F_ ZO w w U ON 0 H w LL 0. w z U= z Permit No. 0a �_ 0p 2- -1- c� 1 l Pro ect Name ��� U :. �C�iv� -• i�-� cr Gc. �CNI �- �l Address CI i of W Suite # Retain inspection schedule, _ .. R. z Needs shift inspection Approved without correction notice Approved with issued correction notice ;Sprinklers: Fire Alarm: ` Hood & Duct .Halon: Monitor: Pre- Fire. Permits: Authorized Signature Date FINALAPP.FRM Rev. 2/19/98 T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206 -575 -4404 • Fax: 206 -575 -4439 z a '~ w J U. U UU CO) LU J = H NU_ wO �Q UD = �w Z F_ ZO w w U ON 0 H w LL 0. w z U= z �g City of Tukwila 1908 i i 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 I RECEIPT Parcel No.: 5422600060 Permit Number: Address: 8801 EAST MARGINAL WY S TUKW Status: Suite No: Applied Date: Applicant: INSURANCE AUTO AUCTION Issue Date: D05 -002 PENDING 01/04/2005 Receipt No.: R05 -00080 Payment Amount: s Initials: SKS Payment Date: User ID: 1165 Balance: 90.20 01/21/200510:23 AM $0.00 Payee: DAVID E. KEHLE ARCHITECT i i TRANSACTION LIST: Type Method Description Amount - - - - - -- -- -- - - - - -- ---------------------------------------- Payment Check 16543 90.20 ACCOUNT ITEM LIST: Description Account Code Current Pmts ------------------------ - - - - -- ---------- - - - - -- ------ - - - - -- BUILDING - NONRES 000/322.100 85.70 PLAN CHECK - NONRES 000/345.830 55.71 PLAN CHECK - RES 000/345.830 -55.71 STATE BUILDING SURCHARGE 000/386.904 4.50 Total: 90.20 qa.2a doc: Receipt Printed: 01 -21 -2005 City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 RECEIPT I Parcel No.: 5422600060 Permit Number: Address: 8801 EAST MARGINAL WY S TUKW Status: Suite No: Applied Date: f Applicant: INSURANCE AUTO AUCTION Issue Date: D05 -002 PENDING 01/04/2005 Receipt No.: R05 -00007 Payment Amount: 55.71 f Initials: SKS Payment Date: 01/04/2005 03:48 PM User ID: 1165 Balance: $90.20 4 Payee: DAVID E. KEHLE ARCHITECT � s TRANSACTION LIST: Type Method Description Amount { Payment Check 16508 55.71 j I ACCOUNT ITEM LIST: Description Account Code Current Pmts ------------------------ - - - - -- ---------- - - - - -- ------ - - - - -- z . PLAN CHECK- RES 000/345.830 55.71 L , t i Total: 55.71 l j j , I t i doc: Receipt Printed: 01 -04 -2005 PERMIT COOPD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D05 -002 DATE: 01 -04 -05 PROJECT NAME: INSURANCE AUTO AUCTION SITE ADDRESS: 8801 EAST MARGINAL WAY SOUTH X Original Plan Submittal Response to Correction Letter # — Response to Incomplete Letter # Revision #after /before permit is issued DEPARTMENTS r L � -13'05 Buildin hit, 0 Fire P ev�ion I 0 Public Works t�n � _n�S Structural ❑ � 1� Planni 'g Division no Permit Coordinator 1 4 DETERMINATION OF COMPLETENESS (Tues., Thurs.) Complete [ Incomplete ❑ Comments: DUE DATE: 01 -06 -05 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS �UTING: Please Route Structural Review Required REVIEWER'S INITIALS: ❑0 APPROVALS OR CORRECTIONS Approved ❑ Approved with Conditions E Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: DUE DATE: 02 -03 -05 Not Approved (attach comments) ❑ rNAIT COORD COPY Documents /routing slip.doc 2.28.02 ❑ No further Review Required DATE: z �w JU UO U) 0 W= J H CO u.; .w O 2 � 9a Nd = W Z F = .. . �- O. z �- LLJ o` U O CO) o f-. w w'. �o .. z: U N: O ~ Z s I i Paawn And Displuy C.unificuto F .M'k1STRR= ..DEPARnIENT OF LABOR AND INDUSTR.IE�9 ', AS PROVIDED BY L a w AS REGISTEREL AS PROVIDED gY LAW 'AS • t Pieria Remove CQh9T,, CONS. , GEIITEERAL . .. �.t.:+.::1: EXP . DATE. And Sign r .t. v.: if.. , :. �;. .. .. � t,.: ,�w..�..z;±:t t. • 01/10/2006.. • Identification EFFEC ^IVE DATE. ..f1,y .�• Card Before C�Wfi�Ani � 17; "� d:'y. rt,,,� j .. �EF r DATE O 2;, Placing In 1501..N .200TH 5T Billfold S G A CORPO_RAT ION . 1501 N. 200TH ST SHOItELZN:; WP_ 981.3.3 Si�t:utu • Paawn And Displuy C.unificuto F .M'k1STRR= AS PROVIDED BY L a w AS CONST CONT GENERAL Pieria Remove 'REGIST : # ' EXP . DATE. And Sign 0001 - .$GAC0t *084ES 01/10/2006.. • Identification EFFEC ^IVE DATE. 01/10 1992 Card Before S G A CORPORATION Placing In 1501..N .200TH 5T Billfold SHORED ip 9 Z Si�t:utu • Isiur l E?A�WrI MENT OF LABOR AND INDUSTRIES Ilt'; WHOO tlss SGTZ££99OZ 9 :0L v0 /ZL /90 �i WA POW PoLf" POW par. POW P. R T IONNG VALL NAIN INK FENCE 9AX NW 1 POL ' • /GlM1EAAlL �.. „��; � I � I 91 3 I BUGLING D F0°""11INWA IMF T. In �.2� M.. 11' AM FT. D4 BWG. % ,. Ifs -12.4 lOOTPR1011 - 5.410t SOFT ] \ SM. HT - 43.41*t. AP& F.F. I a INTER TOUR o F%P ON CONC. PAD ICLE STAGING A o nnp EX. SLAB ICLE STAGING A • _ t 0 1 1 y • - jr V APPROX 200' SETBACK I FROM MHW f� , 1 I 9 _ _ Imo. PROPAFE__,�/_ � EX SLAB If 1E CNC E -337 r( � IRIatT r . \ PowER POLE irALUNAIRE lip SASE FLOW ELEVATKIN - e.4 t MEAN M ON WATER LINE- 4.5 ! FEET � \ x . x � � cow-... a CONC. RETAIN. CK I SRA OUARORML RECESS DOCK o AREA , FLOOR -ISM pla �I �Iw 99 W mi M 1 L i I�'OMER -jug QW. _. - - G - / FM •/MV •/FPS► IEEE r� ® n3.w .�a, ftupo Ts OW" , x 'A k x v ITTITTT�TT'� H 11llll 9 ZrZAoA i i i vZZZZZA, i��� ME A ft wbilum ar any adopted not &Soft i don o Sw�L.K wo 4r Too Gopy and � 1 � Ex. CURB CUT SUPER EXIT d .. ........ ..... 1 SIfB1A1. POLE '� : /LMWAIE Dire \ , 0 a - \\ o low \\ :• ' '�. do BUYER ENTRY 0 \\ ;.� < EXISTING CURS GUT p � 4� / BUGLING B �� \\ n O PULL-OUT/ \ 0 BUYER PARKING \ \� ,.+► Wol EXISF (133) \\ O NEW STRIPING TOQ, NEW r_ ® / 371E fioc/i4w LDI F R t FT I ® > \\ TOP OF W NAt M*TION - 15.17 FEET (NOAH) .... ... I .. I I oloe e t ... .... .... I �° BUILDNG A \\% _ TO BE FelIODELED DER o SEPARATE PERMIT CANOPY 6 o Y BLDG. FOOTPRINT AREA - , 13,970 t SO. FT. -- -- -- - - _ N-M _ - _ _ ®_ I _ I _ _ L I ,,,� BLDG. HEIGHT - 25.4 ABOK F.F. GUARDRAIL WATER o IL -- T 1 / I aUA40RAI I'm 1 2 12' OUARORAII E4 S4.� R '- "- ` - -- -- SLAB FOUNDATI I iuu 0 aA is -t4. I EX SLAB I o o � 1 - I I ' NEW IE b 0 P IUCHT srANDARo E 3z �,� o POLE v/J -BOX a Ole UNIN�IAIRE (LEI) W /L UMINAIRE f C N A I N L I N K Ir E N C E SEMM CORNER (AS NOTED) C STORM lit TION so. SEWR U T STATM 00 POWER o _ a - Er ® UrM MANMOIE (AS NOTED) SURVEY OONTROI STATION ❑ CATCH IMSIN (CO) A& STORM MANHOLE (SDW) ADM GROUND VQ0uT1014 TOWER ` : '• '• , • VAULT Faon�RN+ Allfk .1eseA 90 .n. (NO PIPES! A ` ox. It WO SAS METER ... � � ..... , 1• �.•�' "'`�.' tort. L IT ANNE F.F. 7taL '*^ 414 e/W CIS *I* •v -w- w � • �i WA POW PoLf" POW par. POW P. R T IONNG VALL NAIN INK FENCE 9AX NW 1 POL ' • /GlM1EAAlL �.. „��; � I � I 91 3 I BUGLING D F0°""11INWA IMF T. In �.2� M.. 11' AM FT. D4 BWG. % ,. Ifs -12.4 lOOTPR1011 - 5.410t SOFT ] \ SM. HT - 43.41*t. AP& F.F. I a INTER TOUR o F%P ON CONC. PAD ICLE STAGING A o nnp EX. SLAB ICLE STAGING A • _ t 0 1 1 y • - jr V APPROX 200' SETBACK I FROM MHW f� , 1 I 9 _ _ Imo. PROPAFE__,�/_ � EX SLAB If 1E CNC E -337 r( � IRIatT r . \ PowER POLE irALUNAIRE lip SASE FLOW ELEVATKIN - e.4 t MEAN M ON WATER LINE- 4.5 ! FEET � \ x . x � � cow-... a CONC. RETAIN. CK I SRA OUARORML RECESS DOCK o AREA , FLOOR -ISM pla �I �Iw 99 W mi M 1 L i I�'OMER -jug QW. _. - - G - / FM •/MV •/FPS► IEEE r� ® n3.w .�a, ftupo Ts OW" , x 'A k x v ITTITTT�TT'� H 11llll 9 ZrZAoA i i i vZZZZZA, i��� ME A ft wbilum ar any adopted not &Soft i don o Sw�L.K wo 4r Too Gopy and � 1 � Ex. CURB CUT SUPER EXIT d .. ........ ..... 1 SIfB1A1. POLE '� : /LMWAIE Dire \ , 0 a - \\ o low \\ :• ' '�. do BUYER ENTRY 0 \\ ;.� < EXISTING CURS GUT p � 4� / BUGLING B �� \\ n O PULL-OUT/ \ 0 BUYER PARKING \ \� ,.+► Wol EXISF (133) \\ O NEW STRIPING TOQ, NEW r_ ® / 371E fioc/i4w LDI F R t FT I ® > \\ TOP OF W NAt M*TION - 15.17 FEET (NOAH) .... ... I .. I I oloe e t ... .... .... I �° BUILDNG A \\% _ TO BE FelIODELED DER o SEPARATE PERMIT CANOPY 6 o Y BLDG. FOOTPRINT AREA - , 13,970 t SO. FT. -- -- -- - - _ N-M _ - _ _ ®_ I _ I _ _ L I ,,,� BLDG. HEIGHT - 25.4 ABOK F.F. GUARDRAIL WATER o IL -- T 1 / I aUA40RAI I'm 1 2 12' OUARORAII E4 S4.� R '- "- ` - -- -- SLAB FOUNDATI I iuu 0 aA is -t4. I EX SLAB I o o � 1 - I I ' NEW IE b Lr P IUCHT srANDARo �,� o v/J -BOX a Ole UNIN�IAIRE (LEI) .i f Y00 LICHT SEMM CORNER (AS NOTED) C POWER METER • MW REBAR /CAP (AS NOTED) -0- POWER o _ V 1W 7M wvm k i VIoMNty Mop m O r% Q � O SrTE El � B S No awN am IAA ►.NI RO. UWf4U -WAA.t The Having Company Bell E Marginal Way S. TAX ACCOUNT NUMBER 542260 0060 - 03 LEGAL DESCRIPTION A PORTION OF THE FRANCIS MCNATT DONATION CLAIM NO. 38, M SECTION 33, TOWNSHIP 24 NORTH, RANGE 4 EAST, W.M., IN KING COUNTY, WASHINGTON, BEING THAT PORTION OF TRACT NO. 3 AS SHOWN ON THE PARTITION MAP FILED IN CAUSE NO. 120091, OF THE SUPERIOR COURT OF KING COUNTY, WASHINGTON, MORE PARTICULARLY DESCRIBED AS FOLLOWS: COMMENCING ON THE WESTERLY LINE OF EAST MARGINAL WAY SOUTH, WHICH POINT LINES 167.68 FEET SOUTH OF AN INTERSECTION WITH THE NORTH LINE OF SAID DONATION LAND CLAIM NO. 38; THENCE NORTH 89' 16' 16" WEST, 1499.53 FEET TO THE EASTERLY MAR OF COMMERCIAL WATERWAY NO. 1 (DUWAMISH WATERWAY): THENCE SOUTH 15' GO' 00' EAST, 456.1 FEET ALONG SAID ELY MARGIN TO A POINT; THENCE EAST 1 574 72 FEET TO THE WESTERLY LINE OF SAID EAST MARGINAL WAY SOUTH; THENCE NORTHERLY ALONG SAID WESTERLY LINE AT 481 FEET, MORE OR LESS, TO THE POINT OF BEGINNING. EXCEPT THAT PORTION THEREOF CONVEYED BY MONSANTO CHEMICAL COMPANY TO GREAT NORTHERN RAILWAY COMPANY, ET AL, By DEED DATED MARCH 7, 1957, RECORDED UNDER KING COUNTY RECORDING NO. 4784818. ALSO A PORTION OF THE FRANCIS MCNATT DONATION CLAIM NO. 38, IN SECTION 33, TOWNSHIP 24 NORTH, RANGE 4 EAST, W.M., IN KING COUNTY, WASHINGTON, BEING THAT PORTION OF TRACT 2 AS SHOWN ON THE PARTITION MAP FILED IN CAUSE NO. 120091, OF THE SUPERIOR COURT OF KING COUNTY, WASHINGTON, MORE PARTICULARLY DESCRIBED AS FOLLOWS COMMENCING ON THE WESTERLY UK OF EAST MARGINAL WAY SOUTH, WHICH POINT BEARS NORTH 89' 15' 54" WEST, 2470.01 FEET ALONG TIRE DONATION CLAIM UNE AND SOUTH 23' 4C' 59" EAST, 468.77 FEET ALONG THE WESTERLY LINE OF EAST MAR'GMAL WAY SOUTH FROM THE INTERSECTION OF THE LINE BETWEEN TIME DONATION CLAWS OF FRANCIS MCNATT AND HENRY VAN ASSELT WITH THE EAST UNE OF SECTION 33, TOWNSHIP 24 NORTH, RANGE 4 EAST, W.M. IN KING COUNTY, WASHINGTON; THENCE WEST 1574.72 FEET TO THE EASTERLY LINE OF COMMERCIAL WATERWAY NO. 1; THENCE EAST 1053.10 FEET TO A POINT DESIGNATED HEREIN AS POINT "A" FOR SUBSEOl1ENT REFERENCE; THENCE SOUTH 23' 02' 00" EAST, 46.03 FEET; THENCE EAST 561.38 FEET TO TH WESTERLY LINE OF EAST MARGINAL WAY SOUTH; THENCE NORTH 2T 40' 59" WEST ALONG SAID WESTERLY LINE 297.03 FEET TO THE POINT OF BEGINNING. EXCEPT THAT PORTION THEREOF CONVEYED BY MONSANTO CHEMICAL COMPANY TO GREAT NORTHERN RAILWAY COMPANY, ET AL, BY DEED DATED MARCH 7, 1957 AND RECORDED UNDER KING COUNTY RECORDING NO. 4784818. q ,- 'V EXISTING RAM CONCRETE WALL X 4' TALL CONTAWT WALL TAW 18 A 5W GALLON DIESEL M, SINGLE WALL, UL LISTE TAW FO R ABOVE GISOM pIg!°E►�MG CATION) SINGLE WALL TAW N5 SET � FI- OW"CE -3@ ROM A "TIC TO CONTA1t'lNT, ALL. W61DE AN EXISTINGS RAISED W CONAIIIETE WALL. PLAN VIEW N x ,E: W . I' - dr STD. L ° o W FET�GE / / "` " I I K o e W TALL CNANLINC , O G UDR J-90 AUCTION YARD I I ucxT SM. ". LON 12' FENCE /// I ' CHAIPLIMC (MATCH 1SHICLE DROP I I X) AREA NEW GATE -PAIR 10.0" CHAINIINK FENCE ALONG PROPERTY FINE =" C T I ON SCALE: 1/4• . r • ir 2 Ex nnSoNer ewLDo+61 M14L1 Yv uNDOUIb I 4' -6• ' O Ask MOMW 0-v % N li J � l J SITE PLAN - TI N 13 &E 1 "• I$0' -0' 30' fool 120 Iwo 240' SCALE I a 60 41.6. PLASTIC TO CONTAIN ENT • Y -8" DIA EXISTING RA ISED 4' WNICRETE WALL. UL. LISTED ` MO GAL EX EX GONG. STEEL M TAW SLAB Z i TA:'. LOT Nc, 54 , :2 Kn.nnl {t CONTAINER PROPEO' ES 9229 E. Marginal Wad S. Tuimila, WA. 9el09 Al •••• itibMB1 1 • NlON PtT�E / �1 �'�' �,y' KyD !is / DROP ENTRY NEW GATE PAIR 0 Ifd' -la" ON ;, E"'y ROLLERS C ® " 10' REF Pt NEW GATE T GATE O BE PAIR 10' -0" IN 'Q LOCKED P . PEG. CODE NOTES y no dew I ke M ■ m" r E­4 1. � 000N CHAPTER 22 OF IFC 2003. # 1NN11a1� � ► > wMOI of 2. THE FACILITY IS A "FLEET VEHICLE MOTOR FUEL DISPENSING d \ OlWlriow. FACILITY", FUELING BY PERSONS WITHIN THE EMPLOY OF THE Tvkwft ��B \ O BUSINE Wn: ftybions wB m*f► a nm pbn "ff*111111 REVIEWED F I DISPENSING DEVICE LOCATION: aid nlray hxWft addkW M pion rovi%V '1 CODE COMPUA Q A. IO' OR MORE FROM LOT LINES. p,Ioopf)VE0 B. 10' FROM COMBUSTIBLE BUILDING OR NON - COMBUSTIBLE NOT BUILDING AND SRE - &USTICS A PART OF 1 HOUR ASSEMBLY. C. NON-COMBUSTIBLE OVERHANG PROVIDING WEATHER BUILDING CODE: IBC 2003 JAN 19 2005 PROTECTION IS EXEMPT FROM ABOVE. ZONING: MIC /H U F D. NOZZLE WHEN HOSE IS FULLY EXTENDED WILL NOT REACH SITE AREA: 1,061,980 SF (24.38 ACRES) �, Q WITHIN S' OF BUILDING OPENINGS. SETBACKS: FRONT 20' E. 20' PROM FIXED SOURCE OF I GN ITIO N. 4. SIDES o of Tukwila � 1.4 LESS�'THAN EMERGE FUEL ISLAND I ISLAND AND EL NOT REAR 0 NG DIMSION Z SHUTOFF", IF VIA REMOTE PUMP. FUEL MAX. HEIGHT: 125' BUILDING 6� C) 5. DISPENSING IS DONE BY PERSONS WITIM EMPLOY OF BUSINESS. LANDSCAPE: FRONT 5' Z w 6. DELIVERY VEHICLE LOCATION TO ABOVE GROUND TANK VIA SIDES 0 w E Q.1 POSITIVE PRESSURE, TANKER MUST BE MIN. 25' FROM THE TANK REAR 0 7. FUEL DISPENSIING FAG'II.TI'Y EQUIPMENT SHALL BE MAINTAINED IN PARKING REQUIRED: OFFICE: 3.0/1000 USEABLE WORKING ORDER (SECTION 2205.2.1 THROUGH 2205.2.3). SPELL WAREHOUSE: 1/1000 USEABLE CONTROL (2205.3) SHALL BE MADE TO PREVENT LIQUID SPILLED W DURING DISPENSING FROM FLOWING INTO HUII.DIING VIA GRADE OR RAISED SII.I.S EXISTING UX OF SITE SALVAGE AND WRECKING OPERATIONS WITH ASSOCIATED � I. SMOKING OR OPEN FLAMES ARE PROHIBITED DMINISTRATIVE OFFICES. AND ENGINES BEING w FUELED MUST HE TURNED OFF. POST SIGNS "No SMOKING" AND 04 "TURN ENGINE OFF DURING FUELING". ,ipuw o OCCUPANCY ESL 0 9. PROVIDE PORTABLE FIRE EXTINGUISHERS COMPLYING WITH TO REMAIN: BLDG. A 8 13,913 SF V -6 O U F-4 SECTION 906 WITH A MINIMUM RATING OF 2 -A :20.B:C, TO BE WTIMIM BLDG. 8 S2 «. 75' OF PUNS, DISPENSERS, OR STORAGE TANK FILL PIPE OPENING. 10. KEEP FENCED AND DIKED AREAS SURROUNDING ABOVE GROUND 215,400 SF N - BLDG. E F -NO WORK 16,560 SF V - TANKS FROM VEGETATION, DEBRIS OR OTHER MATERIAL. 11. SECTION 2206.2.3 ABOVE GROUND TANKS OUTSIDE BUILDING. BLDG. C F -NO WORK 1,764 SF V -8 A. TANK MUST BE LISTED AND LABELED PER CHAPTER 34. BLDG. 0 F - WORK 4 1 V - Z H. LOCATION SHALL BE PER TABLE 2206.2.3 TOTAL 253,158 SF r� CLASS I PROTECTED ABOVE GROUND TANKS LESS THAN 6,000 GALLONS, MINIMUM DISTANCE TO IMPORTANT BUILDING IS 5'. NO BUILDING A SECOND FLOOR: B (NOT OCCUPIED) 13.973 SF SEPARATION IS REQUIRED FROM TANK TO DISPENSER co POR FLEET VEHICLE DISPENSING, l5' TO PROPERTY LINE OR PUBLIC PARKING: PROPOSED 203 STALLS (INC. 7 H.C.) co AY. 12. ABOVE GROUND TANKS SHALL HE SAFEGUARDED FROM PUBLIC ACCESS OR UNAUTHORIZED USE. My OF TUkV4LA 13. GUARD POSTS OR OTHER MEANS OF PROTECTION SHALL BE EMPLOYED JAM ; Z B LDG B (THIS TANK SITS WITH A CONCRETE RAISED CONTAINMEENT AREA). Q� 14. SECONDARY COINTAII4MEW IS REQUITED AND SHALL HE MONITORED VISUALLY. ( THIS TANK INSTALLATION IS WITHIN A PLASTIC POUT CATER CONTAINMENT BIN AND THE TANK AND BIN ARE WITHIN A CONCRETE ABOVE GROUND ENCLOSUR E WTTH 4' WALLS.) FUEL 1 S. FUEL DISPENSING} SYSTEMS SHALL BE DESIGNED, FABRICATED AND INSTALLED PER UL LISTING FOR SUCH USE. 16. DOPENSV40 HOSES SHALL BE MAXIMUM 1 111- (SEE DISTANCE TO OPENINGS goo DISPENSING ABOVE) AND HAVE A BREAKAWAY DESIGN. 17. THIS INSTALLATION DOES NOT HAYS REMOTE PUNS FOR PUMPING. IS. OVERFI P RO'TBCTIOIN SHALL BE PROVIDED FOR TANK FILLING TO MAX. •S TE PLAN BASED ON SURVEY SY BARGmU ( 10-31-03) "% O C C 9SX.y WITH AUTOMATIC SHUT - OFF OF FLOW WHEN CAPACITY nWkN4\eoammmrb\CAD\2000O41e Insure" Auobon\8LDG -B-FuvI a.p.owg. Fuel v1 j i4rnM 2:33: LEGEND, P POWER VAULT (As wn) •} ODrCN11AR1c UNIN�IAIRE (LEI) .i f Y00 LICHT SEMM CORNER (AS NOTED) C POWER METER • MW REBAR /CAP (AS NOTED) -0- POWER o F'GIN�ID �AD/rACx ® �MCTpN (AS NOTED) ® UrM MANMOIE (AS NOTED) SURVEY OONTROI STATION ❑ CATCH IMSIN (CO) A& STORM MANHOLE (SDW) j O SANTrARY SEWER MANI'W (SSW) : '• '• , • OONCRETE SANITARY SEWER CLENW (MM) C ® SAS METER ... � � ..... , 1• �.•�' "'`�.' tort. L MVEL Q CIS *I* •v -w- w WATER LINE D4 WATER VKVE (WV) SANITARY SEWER LINE FI1RE HYDRANT SiO �ORM�MC,E LINE � MATER MMrHOIE�) -o -a- ® WATER METER -- TWO --- 1EI.EPH UNDEItCROUNO .a -- P(uc) - POWER Lmomvom MONITOR WELL ` - 'K oN1- POWER OM ERmm -X OM LINK FENCE IAA ►.NI RO. UWf4U -WAA.t The Having Company Bell E Marginal Way S. TAX ACCOUNT NUMBER 542260 0060 - 03 LEGAL DESCRIPTION A PORTION OF THE FRANCIS MCNATT DONATION CLAIM NO. 38, M SECTION 33, TOWNSHIP 24 NORTH, RANGE 4 EAST, W.M., IN KING COUNTY, WASHINGTON, BEING THAT PORTION OF TRACT NO. 3 AS SHOWN ON THE PARTITION MAP FILED IN CAUSE NO. 120091, OF THE SUPERIOR COURT OF KING COUNTY, WASHINGTON, MORE PARTICULARLY DESCRIBED AS FOLLOWS: COMMENCING ON THE WESTERLY LINE OF EAST MARGINAL WAY SOUTH, WHICH POINT LINES 167.68 FEET SOUTH OF AN INTERSECTION WITH THE NORTH LINE OF SAID DONATION LAND CLAIM NO. 38; THENCE NORTH 89' 16' 16" WEST, 1499.53 FEET TO THE EASTERLY MAR OF COMMERCIAL WATERWAY NO. 1 (DUWAMISH WATERWAY): THENCE SOUTH 15' GO' 00' EAST, 456.1 FEET ALONG SAID ELY MARGIN TO A POINT; THENCE EAST 1 574 72 FEET TO THE WESTERLY LINE OF SAID EAST MARGINAL WAY SOUTH; THENCE NORTHERLY ALONG SAID WESTERLY LINE AT 481 FEET, MORE OR LESS, TO THE POINT OF BEGINNING. EXCEPT THAT PORTION THEREOF CONVEYED BY MONSANTO CHEMICAL COMPANY TO GREAT NORTHERN RAILWAY COMPANY, ET AL, By DEED DATED MARCH 7, 1957, RECORDED UNDER KING COUNTY RECORDING NO. 4784818. ALSO A PORTION OF THE FRANCIS MCNATT DONATION CLAIM NO. 38, IN SECTION 33, TOWNSHIP 24 NORTH, RANGE 4 EAST, W.M., IN KING COUNTY, WASHINGTON, BEING THAT PORTION OF TRACT 2 AS SHOWN ON THE PARTITION MAP FILED IN CAUSE NO. 120091, OF THE SUPERIOR COURT OF KING COUNTY, WASHINGTON, MORE PARTICULARLY DESCRIBED AS FOLLOWS COMMENCING ON THE WESTERLY UK OF EAST MARGINAL WAY SOUTH, WHICH POINT BEARS NORTH 89' 15' 54" WEST, 2470.01 FEET ALONG TIRE DONATION CLAIM UNE AND SOUTH 23' 4C' 59" EAST, 468.77 FEET ALONG THE WESTERLY LINE OF EAST MAR'GMAL WAY SOUTH FROM THE INTERSECTION OF THE LINE BETWEEN TIME DONATION CLAWS OF FRANCIS MCNATT AND HENRY VAN ASSELT WITH THE EAST UNE OF SECTION 33, TOWNSHIP 24 NORTH, RANGE 4 EAST, W.M. IN KING COUNTY, WASHINGTON; THENCE WEST 1574.72 FEET TO THE EASTERLY LINE OF COMMERCIAL WATERWAY NO. 1; THENCE EAST 1053.10 FEET TO A POINT DESIGNATED HEREIN AS POINT "A" FOR SUBSEOl1ENT REFERENCE; THENCE SOUTH 23' 02' 00" EAST, 46.03 FEET; THENCE EAST 561.38 FEET TO TH WESTERLY LINE OF EAST MARGINAL WAY SOUTH; THENCE NORTH 2T 40' 59" WEST ALONG SAID WESTERLY LINE 297.03 FEET TO THE POINT OF BEGINNING. EXCEPT THAT PORTION THEREOF CONVEYED BY MONSANTO CHEMICAL COMPANY TO GREAT NORTHERN RAILWAY COMPANY, ET AL, BY DEED DATED MARCH 7, 1957 AND RECORDED UNDER KING COUNTY RECORDING NO. 4784818. q ,- 'V EXISTING RAM CONCRETE WALL X 4' TALL CONTAWT WALL TAW 18 A 5W GALLON DIESEL M, SINGLE WALL, UL LISTE TAW FO R ABOVE GISOM pIg!°E►�MG CATION) SINGLE WALL TAW N5 SET � FI- OW"CE -3@ ROM A "TIC TO CONTA1t'lNT, ALL. W61DE AN EXISTINGS RAISED W CONAIIIETE WALL. PLAN VIEW N x ,E: W . I' - dr STD. L ° o W FET�GE / / "` " I I K o e W TALL CNANLINC , O G UDR J-90 AUCTION YARD I I ucxT SM. ". LON 12' FENCE /// I ' CHAIPLIMC (MATCH 1SHICLE DROP I I X) AREA NEW GATE -PAIR 10.0" CHAINIINK FENCE ALONG PROPERTY FINE =" C T I ON SCALE: 1/4• . r • ir 2 Ex nnSoNer ewLDo+61 M14L1 Yv uNDOUIb I 4' -6• ' O Ask MOMW 0-v % N li J � l J SITE PLAN - TI N 13 &E 1 "• I$0' -0' 30' fool 120 Iwo 240' SCALE I a 60 41.6. PLASTIC TO CONTAIN ENT • Y -8" DIA EXISTING RA ISED 4' WNICRETE WALL. UL. LISTED ` MO GAL EX EX GONG. STEEL M TAW SLAB Z i TA:'. LOT Nc, 54 , :2 Kn.nnl {t CONTAINER PROPEO' ES 9229 E. Marginal Wad S. Tuimila, WA. 9el09 Al •••• itibMB1 1 • NlON PtT�E / �1 �'�' �,y' KyD !is / DROP ENTRY NEW GATE PAIR 0 Ifd' -la" ON ;, E"'y ROLLERS C ® " 10' REF Pt NEW GATE T GATE O BE PAIR 10' -0" IN 'Q LOCKED P . PEG. CODE NOTES y no dew I ke M ■ m" r E­4 1. � 000N CHAPTER 22 OF IFC 2003. # 1NN11a1� � ► > wMOI of 2. THE FACILITY IS A "FLEET VEHICLE MOTOR FUEL DISPENSING d \ OlWlriow. FACILITY", FUELING BY PERSONS WITHIN THE EMPLOY OF THE Tvkwft ��B \ O BUSINE Wn: ftybions wB m*f► a nm pbn "ff*111111 REVIEWED F I DISPENSING DEVICE LOCATION: aid nlray hxWft addkW M pion rovi%V '1 CODE COMPUA Q A. IO' OR MORE FROM LOT LINES. p,Ioopf)VE0 B. 10' FROM COMBUSTIBLE BUILDING OR NON - COMBUSTIBLE NOT BUILDING AND SRE - &USTICS A PART OF 1 HOUR ASSEMBLY. C. NON-COMBUSTIBLE OVERHANG PROVIDING WEATHER BUILDING CODE: IBC 2003 JAN 19 2005 PROTECTION IS EXEMPT FROM ABOVE. ZONING: MIC /H U F D. NOZZLE WHEN HOSE IS FULLY EXTENDED WILL NOT REACH SITE AREA: 1,061,980 SF (24.38 ACRES) �, Q WITHIN S' OF BUILDING OPENINGS. SETBACKS: FRONT 20' E. 20' PROM FIXED SOURCE OF I GN ITIO N. 4. SIDES o of Tukwila � 1.4 LESS�'THAN EMERGE FUEL ISLAND I ISLAND AND EL NOT REAR 0 NG DIMSION Z SHUTOFF", IF VIA REMOTE PUMP. FUEL MAX. HEIGHT: 125' BUILDING 6� C) 5. DISPENSING IS DONE BY PERSONS WITIM EMPLOY OF BUSINESS. LANDSCAPE: FRONT 5' Z w 6. DELIVERY VEHICLE LOCATION TO ABOVE GROUND TANK VIA SIDES 0 w E Q.1 POSITIVE PRESSURE, TANKER MUST BE MIN. 25' FROM THE TANK REAR 0 7. FUEL DISPENSIING FAG'II.TI'Y EQUIPMENT SHALL BE MAINTAINED IN PARKING REQUIRED: OFFICE: 3.0/1000 USEABLE WORKING ORDER (SECTION 2205.2.1 THROUGH 2205.2.3). SPELL WAREHOUSE: 1/1000 USEABLE CONTROL (2205.3) SHALL BE MADE TO PREVENT LIQUID SPILLED W DURING DISPENSING FROM FLOWING INTO HUII.DIING VIA GRADE OR RAISED SII.I.S EXISTING UX OF SITE SALVAGE AND WRECKING OPERATIONS WITH ASSOCIATED � I. SMOKING OR OPEN FLAMES ARE PROHIBITED DMINISTRATIVE OFFICES. AND ENGINES BEING w FUELED MUST HE TURNED OFF. POST SIGNS "No SMOKING" AND 04 "TURN ENGINE OFF DURING FUELING". ,ipuw o OCCUPANCY ESL 0 9. PROVIDE PORTABLE FIRE EXTINGUISHERS COMPLYING WITH TO REMAIN: BLDG. A 8 13,913 SF V -6 O U F-4 SECTION 906 WITH A MINIMUM RATING OF 2 -A :20.B:C, TO BE WTIMIM BLDG. 8 S2 «. 75' OF PUNS, DISPENSERS, OR STORAGE TANK FILL PIPE OPENING. 10. KEEP FENCED AND DIKED AREAS SURROUNDING ABOVE GROUND 215,400 SF N - BLDG. E F -NO WORK 16,560 SF V - TANKS FROM VEGETATION, DEBRIS OR OTHER MATERIAL. 11. SECTION 2206.2.3 ABOVE GROUND TANKS OUTSIDE BUILDING. BLDG. C F -NO WORK 1,764 SF V -8 A. TANK MUST BE LISTED AND LABELED PER CHAPTER 34. BLDG. 0 F - WORK 4 1 V - Z H. LOCATION SHALL BE PER TABLE 2206.2.3 TOTAL 253,158 SF r� CLASS I PROTECTED ABOVE GROUND TANKS LESS THAN 6,000 GALLONS, MINIMUM DISTANCE TO IMPORTANT BUILDING IS 5'. NO BUILDING A SECOND FLOOR: B (NOT OCCUPIED) 13.973 SF SEPARATION IS REQUIRED FROM TANK TO DISPENSER co POR FLEET VEHICLE DISPENSING, l5' TO PROPERTY LINE OR PUBLIC PARKING: PROPOSED 203 STALLS (INC. 7 H.C.) co AY. 12. ABOVE GROUND TANKS SHALL HE SAFEGUARDED FROM PUBLIC ACCESS OR UNAUTHORIZED USE. My OF TUkV4LA 13. GUARD POSTS OR OTHER MEANS OF PROTECTION SHALL BE EMPLOYED JAM ; Z B LDG B (THIS TANK SITS WITH A CONCRETE RAISED CONTAINMEENT AREA). Q� 14. SECONDARY COINTAII4MEW IS REQUITED AND SHALL HE MONITORED VISUALLY. ( THIS TANK INSTALLATION IS WITHIN A PLASTIC POUT CATER CONTAINMENT BIN AND THE TANK AND BIN ARE WITHIN A CONCRETE ABOVE GROUND ENCLOSUR E WTTH 4' WALLS.) FUEL 1 S. FUEL DISPENSING} SYSTEMS SHALL BE DESIGNED, FABRICATED AND INSTALLED PER UL LISTING FOR SUCH USE. 16. DOPENSV40 HOSES SHALL BE MAXIMUM 1 111- (SEE DISTANCE TO OPENINGS goo DISPENSING ABOVE) AND HAVE A BREAKAWAY DESIGN. 17. THIS INSTALLATION DOES NOT HAYS REMOTE PUNS FOR PUMPING. IS. OVERFI P RO'TBCTIOIN SHALL BE PROVIDED FOR TANK FILLING TO MAX. •S TE PLAN BASED ON SURVEY SY BARGmU ( 10-31-03) "% O C C 9SX.y WITH AUTOMATIC SHUT - OFF OF FLOW WHEN CAPACITY nWkN4\eoammmrb\CAD\2000O41e Insure" Auobon\8LDG -B-FuvI a.p.owg. Fuel v1 j i4rnM 2:33: TA E \ c EMPLOYEE/ CUSTOMER 0) (D ENTRY EXISTMCs CURB CUT Go 00 a M (D Z M et (A' CD CD �- \ r 00 'a N N TALL WhILW / ` r •, co ; W / Z o a r p x N CL LA_ Ir- \ loop .i C �0 .j } y� C W � � V V � i � ag � i � O OC D f�. CTf ! !R Z Z Inn E \ c EMPLOYEE/ CUSTOMER 0) (D ENTRY EXISTMCs CURB CUT Go 00 a M (D Z M et (A' CD CD �- \ r 00 'a N N TALL WhILW / ` r •, co ; W / Z o a r p x N CL LA_ Ir- \ loop