Loading...
HomeMy WebLinkAboutPermit D05-049 - STARBUCKS - TENANT IMPROVEMENTSTARBUCKS COFFEE 17480 SOUTHCENTER PY EXPIRED 11-14-05 D05-049 City 6. Tukwila Steven M. Mullet, Mayor Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: ci.tukwila.wa.us DEVELOPMENT PERMIT Parcel No.: 2623049110 Address: 17480 SOUTHCENTER PY TUKW Suite No: Tenant: Name: STARSUCKS COFFEE COMPANY Address: 17480 SOUTHCENTER PY, TUKWILA WA Permit Number: Issue Date: Permit Expires On: Steve Lancaster, Director DOS -049 05/18/2005 11/14/2005 Owner: N Name: MSK NORTHWEST Phone: j Address: 7690 SW MOHAWK ST, TUSALATIN OR N Contact Person: Name: JUSTIN EVANS Phone: 253 893 -3127 Address: 804 W MEEKER ST, KENT, WA End Time: Contractor: N Name: ELITE COMMERCIAL CONTRACTING Phone: j . Address: 804 WEST MEEKER STREET, KENT, WA N Contractor License No: ELITECCO20CD Expiration Date: 02 /06/2007 DESCRIPTION OF WORK: N TENANT IMPROVEMENT OF EXISTING SPACE FOR EXISTING TENANT. REMOVING EXISTING CABINETS, INSTALLING NEW CABIENTS, REMOVING FLOOR TILE AND FINISH AS NECESSARY; INSTALLING NEW CHAIR RAIL AND COUNTER TOPS, PAINT. N Value of Construction: $40,000.00 Fees Collected: $1,114.59 Type of Fire Protection: SPRINKLERS International Building Code Edition: 2003 Type of Construction: VB Occupancy per IBC: 0019 Public Works Activities: N Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: N Hauling: N Start Time: End Time: Land Altering: N Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: N Moving Oversize Load: N Start Time: End Time: Sanitary Side Sewer: N Sewer Main Extension: N Private: Public: Storm Drainage: N Street Use: N Profit: N Non - Profit: N Water Main Extension: N Private: Public: doc: IBC- Permit D05 -049 Printed: 05 -18 -2005 Z UO cn w Lq H . CQ LL w O: J' LL Q D. ? t- 1— O Z F_ W LL I Do O N.. W .L O: Z U tn, S' O ~ Z.. . Steven M. Mullet, Mayor Steve Lancaster, Director Z � UJ QQ �: 0 O.` � w J U- 0 OC �� lL Q; Cy F=— W, 2 Z I—; 5; U 0 N` W Wi F=- V Z; 1-- 0 Z dom IBC- Permit D05 -049 Printed: 05 -18 -2005 i f O A r� City GA "Tukwila Steven M Mullet, Mayor Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: ci.tukwila.wa.us Permit Number: Issue Date: Permit Expires On: Steve Lancaster, Director D05 -049 05/18/2005 11/14/2005 Permit Center Authorized Signature: , Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this wo! will be complied with, whether specified herein or not. The granting of this regulating corjgruct Signature: Print t/does not presume to give authority to violate or cancel the provisions of any other state or local laws the performance of work. I am authorized to sign and obtain this development permit. Date: S �- Z V u S i i,, �vAvNS This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Z h W W Q � Wes. UO o . J � CO LL W QQ O }} U- ¢: S2 a H =. Z P. O : LU C3 o �'. o E-- W w'. —O 111 Z O Z City of Tukwila 1908 Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 PERMIT CONDITIONS Z Parcel No.: 2623049110 Permit Number D05 -049 w Address: 17480 SOUTHCENTER PY TUKW Status: ISSUED 2 Suite No: Applied Date: 02/14/2005 0 STARBUCKS COFFEE COMPANY Issue Date: 05/18/2005 v Tenant: CO) o 1: ** *BUILDING DEPARTMENT CONDITIONS * ** co U. w� 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. LL 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to 3: 0 start of any construction. These documents shall be maintained and made available until final inspection approval is Z F =„ granted. 4: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design Z F- g 5 requirements of ASCE 7. v o ON 5: All construction shall be done in conformance with the approved plans and the requirements of the International LU Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. v 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Department of LL O Z Public Health - Seattle and King County (206/296- 4932). v co 7: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department z of Labor and Industries (206/248- 6630). 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ** *FIRE DEPARTMENT CONDII IONS * ** 10: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 11: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 12: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) doe: Conditions 005 -049 Printed: 05 -18 -2005 �g City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 13: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 14: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 15: Doors shall swing in direction of egress travel where serving an occupant load of 50 or more persons or a Group H occupancy. (IFC 1008.1.2) 16: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 17: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 18: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 19: Means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. The means of egress illumination level shall not be less than 1 foot- candle (11 lux) at the floor level. The power supply for the means of egress illumination shall normally be provided by the premise's electrical supply. In event of a power failure an emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 20: Maintain sprinkler coverage per N.F.P.A. 13. Addition /relocation of walls, closets or partitions may require relocating and /or adding sprinkler heads. (IFC 901.4) 21: All new srpinkler sysetms and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and /or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 22: Maintain fire alarm system audible /visual notification. Addition/ relocation of walls or partitions may require relocation and /or addition of audible /visual notification devices. (City Ordinance #2051) 23: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 24: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 25: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and doc: Conditions 005 -049 Printed: 05 -18 -2005 Z Z �w U CO 0 w� U) L w o� L? � = uj z �O Z �_ 2� U O �. 0H W W LO w z U= O z E i City o f Tukwl l a Department of Community Development / 6300 Southcenter BL Suite 100 / Tukwila WA 9 Y P � 8188 / (206) 431 -3670 #2051) 26: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 27: ** *PUBLIC WORKS DEPARTMENT CONDITIONS * ** 28: Applicant shall obtain a separate Public Works Type C Construction Permit to install required backflow on domestic water service and upgrade the existing landscape irrigation water meter per attached May 10, 2005 letter. This work shall be completed by August 10, 2005. * *continued on next page ** Z Z' W' UO N W. Wm LL., W O: LL ¢. to a. sw Z . � Z� CO' o w w; LL H- Lu z U CO), O Z City of Tukwila i Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or thwiJerformance of work. Signature: i Print N m i i doc: Conditions Date: 5 �e D05 -049 Printed: 05 -18 -2005 Z UO U. N 0 w =. LL w O'. 9 CO =Y = C!. W Z� H O' Z F— UJI 2 5; Mp O N W W.' H O L) F— F- O Z CITY OF TUKW[ 1 tiZ Community Development Department g Public Works Department Permit Center 1905 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 Building Permit No. b os - _ Mechanical Permit No. Public Works Permit No. Project No. use Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** .SITE LOCATION King Co Assessor's Tax No.: =M&2 " ��ffd Site Address: 1 S°� - cHGp� -r Pori rcwa. Suite Number: Floor: It Tenant Name: S'*AieBuc.wS C-orPtE New Tenant: ❑ ...... Yes ©..No Property Owners Name: t1(3k t3otz - Vri west Mailing Address 4ot uTaH IAyE S. S 0119 - '200 Se&7ya City State Zip CONTACT PERSON Name: J.1 s'r 1 PJ Eck*`' S Day Telephone: ZS T `i'S- 31 z'1 Mailing Address: %b1A WF-Scr Me£KCe S t, K*4 6 4 IN 4gp3Z City State Zip E -Mail Address: JQ s "A E C EL % - - CAM Fax Number: ZS 3 - %9'5- 3 y GENERAL CONTRACTOR INFORMATION - (Mechanical Contractor information on back page) Company Name: C.o " Mailing Address . C0 4 %4e%-T MER -w,4e • S'z'tiEe:_T KV-1. - c WX 11637- City State Zip Contact Person: 1 v S'T' ti res S Day Telephone: E -Mail Address: 3 ta s - r 0 ­ 4 F— Q. E A- % - ec. Fax Number: z S a 31 Contractor Registration Number: IEl-1"M LC_ 4d co G 6 Expiration Date: * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** I ARCHITECT OF RECORD -All plans must.be wet stamped by Architect of Record ' Company Mailing Address. Contact Person: E -Mail Address State Zip Day Telephone: Fax Number: ( ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record I Company Name:. Mailing Address; Contact Person :_ E -Mail Address City \applications\pennit application (7.2004) Nee 1 City State Zip Day Telephone: Fax Number: Z '~ W JU U Cl) C3 J = H CO W OC Ei LL Q co = a �. w Z 1- O Z W U� O- 0 I- WW H� U. O W Z U= O ~ Z BUILDING PERMIT INFOR" "ATION - 206431 -3670 Valuation of Project (contractor's bid price): $ 4 4 b,602 Existing Building Valuation: $ Scope of Work (please provide detailed information): T J 1 R E M*Q&- 01P Ex% ST IsJ S S PAc.6 ib i ¢N AN"T RGMt�J� FIST Iwi c/'�RINE'FS. INS'►<1k- NG W QIc'iS � .✓CT S (�,�r..�e. ✓� �buor� - C< N�s N AS MC- .fT1±t ArsS-'ALI,. WSW cHPIR &&,fl- s C. F I . PAINT. Will there be new rack storage? ❑ .. Yes W..No If "yes ", see Handout No. for requirements. Provide All Building Areas in Square Footage Below Single - family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑..... Yes No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: Sprinklers ❑ ... Automatic Fire Alarm ❑ ... None ❑ ... Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ ...Yes Va' If "yes'; attach list of materials and storage locations on a separate 8 -112 x I I paper indicating quantities and Material Safety Data Sheets. �applications\pertnil application (7.2004) Paee 2 Z iH Z �W JU 0 N J �_-. CO LL WO LL co �W Z F- E O Z I-- �5 UC3 ON o E- WW HF- F- .Z U= O Z Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC I' Floor Y 2 0 ,�- 2" Floor 3` Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck Single - family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑..... Yes No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: Sprinklers ❑ ... Automatic Fire Alarm ❑ ... None ❑ ... Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ ...Yes Va' If "yes'; attach list of materials and storage locations on a separate 8 -112 x I I paper indicating quantities and Material Safety Data Sheets. �applications\pertnil application (7.2004) Paee 2 Z iH Z �W JU 0 N J �_-. CO LL WO LL co �W Z F- E O Z I-- �5 UC3 ON o E- WW HF- F- .Z U= O Z PUBLIC WORKS PERMIT I F ORMATION — 206433 -0179 Scope of Work (please provide detailed information): R 1Gw%oV E c-^ roww7r.S _ t ry s -T^ Vo. mrcQ �+'gt�NETS, R. E.w.o.rE rLoort '"C t��' t lrtN ASS NtcGsyt�� �ws taE.ht t.t�ActGZ �,�� i cac Z.is� pAt,w -t. Call before you Dig: 1- 800424 -5555 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District i ❑ ...Tukwila ❑ ... Water District #125 ❑... Highline ❑ ... Renton ! ❑ ... Water Availability Provided Sewer District ❑ ... Tukwila ❑ ... Va1Vue ❑... Renton ❑ ... Seattle ❑ ...Sewer Use Certificate ❑ ... Sewer Availability Provided ❑... Approved Septic Plans Provided ❑ ... Septic System - For onsite septic system, provide 2 copies of a current septic design approval by Kin ounty Health Department. Submitted with Application (mark boxes which auoly): ❑ ... Civil Plans (Maximum Paper Size -22" x34' ❑ ... Technical Information Report (Storm Drainage) ❑ ... Bond ❑... Insurance ❑ ...Easement(s) Prouosed Activities (mark boxes that annlv): ❑ ... Right -of -way Use - Nonprofit for less than 72 hours ❑ ... Right -0f - -way Use - No Disturbance ❑ ... Construction/Excavation/Fill - Right -of -way Non Right -of -way ❑ ... Total Cut cubic yards ❑ ...Total Fill cubic yards ❑ ... Sanitary Side Sewer ❑ ...A ❑ ... Cap or Remove Utilities ❑ ...0 ❑...Frontage Improvements ❑ ...P ❑ ... Traffic Control L ❑ ... Backflow Prevention - Fire Protection " Irrigation " n ❑ ... Permanent Water Meter S' e... WO #_ ❑ ... Temporary Wat/Me Size.. WO # ❑... Water Only Me........... WO #❑ ... Sewer Main E ........... Public Private ❑ ... Water Main xtension .............Public Private ❑... Geotechnical Report ❑ ...Traffic Impact Analysis ❑... Maintenance Agre ent(s) El ...Hold Harmless ❑... Right -of- y Use - Profit for less than 72 hours ❑... Right way Use— Potential Disturbance }'j... Work in Flood Zone El ... Storm Drainage Tank nt Cut Fire Line ❑ ...Grease Interceptor ❑ ...Channelization ❑ ...Trench Excavation ❑ ...Utility Undergrounding ❑ ...Deduct Water Meter Size......... is FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ ... Water ❑ ... Sewer ❑ ... Sewage Treatment Monthly Service Billing to: Name Day Telephone Mailing Address City State Zip Water Meter Refund/Billing: Name Day Telephone Mailing Address City State Zip \applications \permit application (7 -2004) Pam 3 S Z ;= Z W QQ� WV UO CO 0 C0 W J �. CO U 0 J LL ?. N W Z= H 1— O Z 1—_ W � U O N 0 f— WW lL O. •Z W U= O F- Z MECHANICAL PERMIT INS. JRMATION — 206431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name:, Mailing State Zip Contact Person: E -Mail Address: Contractor Registration Number: _ * *An original or notarized copy of Valuation of Project ( Scope of Work Day Telephone: Fax Number: Expiration Date: State Contractor License must be presented at the time of permit issuance ** price): $ detailed information): Residential: New ..... ❑ Commercial: New .....0 Fuel Tyge Electric ...... ❑ Gas ..... ❑ Replacement ..... El Replacement ..... El Other: Indicate type of mechanical work being installed and the quantity below: Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler/Compressor: Qty Furnace<100K BTU Air Handling Unit >I0,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace>l00K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood Water Heater 50+ HP /1,750,000 BTU Heat/Refrig /Cooling System Incinerator - Domestic Emergency Generator Air Handling Unit <10,000 CFM I Incinerator - Comm/Ind I I Other Mechanical Equip ment .PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review- Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the _J�rm Building Code (current edition). No application shall be extended more than once. I HEREBY CERTIFY PENALTY OF PERJUM BUILDING Signature: Prin am Mailing X AGENT: Date: &5 Gyows Day Telephone: ZS 3 - 10 - ' 31w S : gay I✓ES ,r1ArEet rz s ileti T wA Fa City State Zip Date Application Accepted: Date Application Expires: Staff Initials: 4/-a'` \applications\pcnnit application (7 -2004) Paee 4 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER E LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Z �W QQ� JU UO NO C0 W W = H WU_ WO U. Q CO) = �W Z F- ZF- LLJ W U� ON O I-- WW (U -O -- Z co ~O h- Z i�..Q City of Tukwila I 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 RECEIPT Parcel No.: 2623049110 Address: 17500 SOUTHCENTER PY TUKW Suite No: Applicant: STARBUCKS COFFEE COMPANY Permit Number: Status: Applied Date: Issue Date: D05 -049 PENDING 02/14/2005 Receipt No.: R05 -00203 Initials: SKS User ID: 1165 Payment Amount: Payment Date: Balance: 1,114.59 02/14/2005 01:57 PM $0.00 Payee: ELITE COMMERCIAL CONTRACTING, INC. TRANSACTION LIST: Type Method Description Amount ---- - - - - -- -- - - - - -- --------------------- - - - - -- ------ - - - - -- Payment Check 28992 1,114.59 i ACCOUNT ITEM LIST: Description -------- - - - - -- Account Code - - -- Current Pmts ---------- - - - - -- ---- - - - - -- ------ - - - - -- BUILDING - NONRES 000/322.100 672.78 PLAN CHECK - NONRES 000/345.830 437.31 STATE BUILDING SURCHARGE 000/386.904 4.50 i. C Total: 1,114.59 Z Z W: UO Mo w= J F- N LL: W O. U- a: N = _ °, W. ? t--. ' z 0; W. U � O N . W W s u. O , 111 Z' U Z 9907 02/15 9716 TOTAL 1114.59 doc: Receipt Printed: 02 -14 -2005 W � CJt woo �D ~ d O O MOM O 0 �Q �C NOTICE: IF THE DOCUMENT IN THIS FRAME IS LESS CLEAklkAN THIS NOTICE IT_ IS DUE TO THE QUALITY OF THE DOCUMENT. __ O JE // JUSTIN EVANS 804 W MEEKER ST KENT, WA 98032 City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director RE: Permit No. D05 -049 17480 SOUTHCENTER PY TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Permit Center at 206 - 431 -3670 to arrange for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve a one -tine extension up to 180 days. Extension requests must be in writing and Provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 11/14/2005, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, p L J 1 fifer Marshall, Permit Technician xc: Permit File No. D05 -049 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 -431 -3670 • Fax: 206 - 431 -3665 Z z w u� D JU L) 0 , CO U . N w' w O. J. (L Q Vd W. F— O Z F- w =: U � O N, = LU U, w O, tLl Z H H. O Z S 1 I LA gs ot. =r City of Tukwila Steven M. Mullet, Mayor • Department of Community Development Steve Lancaster, Director 1908 September 16, 2005 Dewaine Bednarik Elite Commercial Contracting j 804 Meeker Street { Kent, WA 98032 S RE: Release of Bond Bond No. 104442267 i . Dear Mr. Bednarik: f . This letter hereby authorizes the release of the bond referenced above in the amount of $15,375.00 for the property located at 17480 Southcenter Py, Tukwila, Washington. If you should have any questions, please contact our office at (206)431 -3672. l Sincerely, f Brenda Holt Permit Coordinator end xc: Permit No. D05 -049 i i Z �z W. JU o N 0: N W W =: LL w O J: u_ Q � OI H W. 1- O: Z ~' w, 5: � p O N; ww. H U- . O U CO O Z i �w w City of Tukwila `♦ 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 206- 431 -3670 } DEVELOPER'S PROJECT WARRANTY REQUEST FORM i Section 1 — to be completed by Developer t,IGiLS Cfi���� CO . ' Name of Development: `J7 Date: 0 5 i Address:! Jo CP,vAr Permit No.: �5'0�(� Release should be sent to: Name: ELIri5 C'0R1'16iGG' 11k-,, COiU G / Address: City/State /Zip l`� �/ . b0 ? {n. - Ibc"191n Description of items to be completed (reference plans /documents where items are described): 1 0 87? ,u 7- ,tea iIL15-179-CL A .bOH6�5� �c G>r,17 APiOK //U /4 F��49 41 7710 �_ r 1 1 i t As the owner, or authorized agent of the owner, I hereby submit cash or cash equivalent in the amount of $ 15 375 1 OU (150% of value to complete work above) and attach support documentation for value of work. I will have this work carried out and call for a final inspection by this date: eP 2G�r risk having the City use these funds to carry out the work with their own contractor or in -house manpower. If I fail to carry out the work, I hereby authorize the City to go onto the property and carry out completion of the above deficiencies. I further agree to complete all work listed above prior to requesting inspection and release of these funds. Signed: Title: Section 2.- to be completed by City staff THIS FUND IS AUTHORIZED TO BE ACCEPTED Signed:_ Amount: s ❑ Cash /Check City Receipt No.: Department Head: Deposited this Dat ❑ Cash Assignment )5d Bond 1 OH�y229 Received By: 11 Section 3 — to be completed by Developer All work identified in Section 1 of this form has now been completed and returned to department which authorized warranty. I hereby request inspection and release of my cash /cash equivalentibond. Developer's Representative: Date: To be completed by City staff I I have reviewed the above work and found it acceptable and therefore authorize the release of the above A caqh;(gyash equivalent/bond. Inspector: I :t�Ncl Date: �— 0 Authorized By: Section 4 — to be completed by City staff Amount Released: $ I S %- 0 0 ❑ Check - Check No. ❑ Cash Equivalent — Letter attached Bond — Letter attached Date Released: I I& Released by: *I Icy and proccclura4cd bookWoceloper's project Warranty form 1� Created: Fcbniary 7tMU Z Z �w QQ JU UQ CO C0 LL w O L� cf)a =w Z �- O Z F- w w U O CO off w �O id CO) O Z Y� } Bond No. 10444 2267 f KNOW ALL BY THESE PRESENTS, That we E lite Commercial Contracting, Inc. 3 as Principal, and the Travelers Casualty nd Sure Co of America m y y p y as Surety, are held and firmly bound r unto the City of Tukwila *Fifteen thousand three hundred seventy five and in the just and full sum of y ' 00 /100* ($ 15 9 375.00 ) Dollars, for which sum, well and truly to be paid, we bind ourselves, our heirs, executors, administrators, successors and assigns, jointly and severally, firmly by these presents. 1 Sealed with our seals, and dated this 9 th day of May 2005 THE CONDITION OF THIS OBLIGATION IS SUCH, that, whereas, the Principal has agreed to the completion of Installation of R educed Pressure Principle Assembly (RPPA) with freez } Protection in Tukwila, WA. NOW, THEREFORE, If the said Principal shall well and truly construct said improvements during the term thereof or any extension of said term that may be granted by Obligee with or without notice to the surety, 'then this obligation to be void; otherwise, to remain in full force and effect. Elite Commercial Contracting, Inc. (Principal) I By. Travelers Casualty and Surety Company of America (Surety) i B �. . R.A. Fix , , Attomey - In , - Fact j RECEIVED CITY OF TUKWII.A MAY 1 0 2005 PERMIT CENTER dos 0 V Z W �QQ 2. W UQ N W J CO W O J = cy: �W Z � ZO W LLJ 2 U 0: 1 3 W W : X � 0 lil Z O H Z 4 . . ,I r I. fi 1 May 10, 2005 To: The City of Tukwila Public Works Department 6200 Southcenter Boulevard Tukwila, WA 98188 -2544 Phone: 206 433 -1800 From: Elite Commercial Contracting Dewaine Bednarik 804 West Meeker Street Kent, WA 98032 Phone: 253- 893 -3100 Re: Permit # D05 -049 Review # 1 dated 02/24/05 Starbucks Coffee Company 17480 Southcenter Parkway Tukwila, WA CORRECTION LTR # L-_, To Whom It May Concern: It is the intent of Elite Commercial Contracting in conjunction with Starbucks Coffee Company to comply with Washington State Department of Health requirements for protection of water supply systems. It is furthermore our intent to install the required Reduced Pressure Principal Assembly (RPPA) with freeze protection as close as possible to the permanent water meter for this building. For installation of the RPPA, Elite Commercial Construction will install under a separate Public Works permit. Elite will provide installation plans consisting of a schematic that clearly shows the location of the water meter, in relationship to the property line(s) and the building water meter size(s), water main connection and service to the property, together with a construction cost estimate to the Permit Center. It is the objective of Elite Commercial Contracting to comply with a financial guarantee of 150% of the project cost, estimated at 10,000 by Merit Mechanical and will be completed within 120 days of the date of this letter. Thank you for your attention and cooperation in this matter, CITY OF TUKWILA RF-Cr. ED MAY 1 0 2005 PERMIT CENTER Dewaine Bednarik MAY 10 2005 Vice President Elite Commercial Contracting TUKWILA PUBLIC WORKS . i)05 .- 0 Y9 Z Z �w J U; 0 0 1 W= J H; w O' U- 0: Z �— �o O N; 0 w ui' H U .1L H ` W z U N z Apr, 28, 2005 2:37PM `t Mechanical, Inc, No, 2501 P, 2 PROPOSAL = 14016 TO 'DEWAINE BEDNARIK ELITE COMMERCIAL CONT INC 804 W MEEKER ST STE 201 KENT, WA 98032 -5702 Phone (253) 893 -3100 rox (253) 893 -3101 Page 1 Merit Mechanical, Inc. PQ Box 2109 Redmond, WA 98073 - 2109 Phone: (425) 883 -9224 Fax. (425) 867 -0962 04/28/2005 1 Po # Job Nom/ Location $TUCKS TUKWILA 17480 SOUTHCENTER PKWY SEATTLE, WA 98188 Phone ( ) - 206 Fax ( ) - 206 ME This is a proposal to provide all labor, material, equipment, and permit to: A. Provide and install one Watts 2" 909 RPBA in a hot box within 18" of the customers water meter. The installation will be done per City of Tukwila specifications. Price includes: - Coordinating w/ the building property management company and building engineer for the purpose of shutting down the water to the-complex while the changeover is completed. This will take approximately 5 hours to complete. - Excavation, backfill, trench cover, and safety barricades as required. Maximum excavation depth of 4 0 11 is allotted for in this bid. - Removal of the existing landscape plants and sod as needed. - Reconfiguring the irrigation supply piping as needed for the purpose of placing the new RPBA within 18 inches of the meter box. -Shop drawings and design drawings for permit submittal with the city. - Allowance of $325.00 for the cost of plan review and cost of permit. - Allowance of $500.00 for cost of landscape restoration. B. Provide and install one 1 water meter on the irrigation supply piping near near the water meter and after the newly installed RPBA. This meter to meet City of Tukwila speoifications as written on the letter dated 2- 18 -05. Price includes RECENEO - Excavation, backfill, trench cover, and barricades as required. Maximum CITY OF TUM excavation depth of 40 is allotted for in this bid. - Installing the new motor at the same time the water line is changed to MAY 1 0 20 accommodate the new RPBA. - besign and shop drawings for permit submittal with the city. - Allowance of $275.00 for the cost of plan review and cost of permit. PERMIT CENT - Installation of a plastic meter box over the new water meter. C. Exclusions and Conditions 1. Price excludes any modifications to the fire system backflow protection equipment. 2. Property management, tenants, and equipment owners will be responsible for all hutdown, securing, and restarting any water cooled equipment as needed. 3. Price excludes cost of electrical circuit to the hot box and any subsequent heat tape. 4. All new under ground piping to be Type "L" copper w/ closed cell insulation to protect it from the native soils. (Continued) Dlos:woy? z z W J U. UO ND CO) LU J S2 LL W O 9 _ U Q CY ry = W H =. Z� F- O z 2 :5 U �O �; D F- W W I=- P LL O: W z U CO O z Apr, 28, 2005 2:37PM I "`i,I Mechanical, Inc, No, 2501 P. 3 PRO' POSALIt10. 14016 Page 2 Merit Mechanical, Inc, PO Box 2109 Redmond, WA 98073.2109 Phone: (426) 883 -9224 Pax: (425) 867 -0962 TO 'DEWATNE BEDNARIK Date 04/28/2005 PO # ELITE COMMERCIAL CONT INC Job Name/ 804 W MEEKER ST STE 201 KENT, WA 98032 -5702 zaoation STARBUCKS TUKWILA 17480 SOUTHCENTER PKWY SEATTLE, WA 98188 Phone (253) 893 -3100 FF= (253) 893 -3101 phoaa ( ) - 206 Fax ( ) - 206 5. Dewatering the excavations if required will be extra. 6. Price is based on back filling w/ native soil; export or import of fill is extra. 7. Price is based on working during normal business hours; after hours work will be extra. 8. Price excludes sales tax 9. Any work not specified in the scope above will be extra. All additional costs will be authorized in writing before continuing work. CITY OF: TUK MAY 1 0 2005 PERMIT CENTEn Ten Thousand Two Hundred Fifty Dollars and 00 cents $10,250.00 Payment to be made as follows: MONTHLY PROGRESS BILLINGS NET 30 DAYS, FINAL BALANQE NET 30 bAYS FROM INVOICE, 1 3/43 INTEREST CHARGED MONTHLY ON ALL PAST DUE AMOUNTS, MO s—M MWI TY ON ALL W Od2MSHIP ANO MATERIALS, MAHUMTUR5S WX %RM 9' ON Authorized ALL 3QV' - A= # 3ON?5, VALUER, AND CONTROLS, NO WNWTY ON ANY 19CERIALS OR EQVISONUT 7.Rovmw 3% or=Rs. No W7Lawy ON ANY °MU MNO EOVIZUSNT, Signature PLUM.9ING, PIPING SYST"=, ?UH25, 0.3 CONTROLS. Submitted By: Scot MacColman Note: This proposal may be irithftawn by us if not aoc pted within 45 days Acceptance of Proposal Signature Date of Aaeeptance: Print Name DOS 0 (19 Z z Z. �W: �U :t) O co) ( . J H S2 W. 2 La c a, = W Z H- O Z F— W UJ �p O N. W U- O W Z H =: O Z a X 41\ . City of Tukwila FEB 2 4 2005 I Steven M. Mullet, Mayor Department of Public Works [BY: February 18, 2005 MBK Northwest 2401 Utah Avenue South, #800 Seattle, WA 98134 RE: Starbucks Coffee Company Tenant Improvement 17480 Southcenter Pkwy, Tukwila WA Permit No. D05 -049 To Whom It May Concern: F. Morrow, P.E., Director In accordance with Washington State Department of Health guidelines for Group A Public Water Systems, Public Works has implemented a cross - connection control program to protect the public water system from contamination via cross - connection. The program requires elimination or control of any cross - connection between the distribution system and a consumer's water system by the installation of an approved backflow device. Since this project includes alterations to the existing plumbing system, the entire plumbing system must be brought up to the current standards as set forth in the Uniform Plumbing Code including installation of an approved backflow prevention on the fire line, irrigation line and the water supply to the building. The City has determined that the building at the above address has deficiencies on the domestic water supply and landscape irrigation. a) Domestic Water A Reduced Pressure Principle Assembly (RPPA), previously called a Reduced Pressure Backflow Assembly (RPBA), shall be installed immediately downstream of the permanent water meter. Installation at another location requires the Public Works Director's approval. The RPPA shall be installed in a Hot Box or equal freeze protection enclosure anchored to a. minimum 4" thick i concrete pad. Public Works highly recommends a power supply be provided for the Hot Box. b) Landscape Irrigation The existing irrigation deduct water meter shall be upgraded with a Sensus ECR -WP register that is compatible to the Invensys automatic reading system and register ring. The Public Works Director will withhold issuance of Starbucks Coffee Company Tenant Improvement permit until the Permit Center receives plans for installation or a bond for installation of an RPPA on domestic water and upgrade of irrigation water meter. RECEIVED CITY OR TUKWIU► MAY 1 0 2005 PERMIT CENTER Z Z. �QQ W WD J UO CO) w= J S2 U. ,w U_ Q cf) a. =W Z� �_ O: Z E-. W �o ON O I— W LL. O _ u.i U= O� Z 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 -433 -0179 • Fax: 206 - 431.3665 f • MBK Northwest Page 2 February 18, 2005 If you opt to install, you may install under a separate permit or under a revision to the Tenant Improvement permit D05 -049 application. If you opt to install under the Tenant Improvement permit, z you must supply the installation plans consisting of a schematic that clearly shows the location of the 0— Z irrigation deduct and domestic water meters in relationship to the property line(s) and the building, At w fff sizes of all water meters, connections to the water main, and service to the property together with a construction cost estimate to the Permit Center as a revision to the Tenant Improvement permit v p j application. RPPA installation and irrigation modifications will trigger a Public Works Type C N W { Construction Permit, which has a progressive fee. For a Type C permit, Public Works collects a base w s application and plan review fee ($250.00 plus 2.5 % of construction cost for RPPA installation and CO u irrigation modifications) when the application or revision to this TI is submitted. An additional 2.5 % w 0 of construction cost for RPPA installation and modifications to the irrigation system will be assessed at the time of permit issuance. U- Q S2 C'Y If you opt to bond for the installation, you must provide the following to the Permit Center: 1) an w original design and installation estimate, 2) a bond for 150 % of the design and installation cost, and 3) ? a letter stating your intent to install the backflow and modify fire and irrigation systems by a certain Z O date. This must be done before the Permit Center issues the permit w w ?0 I have enclosed Public Works Bulletin 1 to help you. Please call Mike Cusick, Public Works Senior ,p N; Water and Sewer Engineer, at (206) 431 -2441, or Jim Morrow, Public Works Director, at (206) 433- 7161, if you have any questions. w w l U. p Sincerely, U O 0 .J y v Z..... . Joanna Spencer Development Engineer i � JS:lw enclosures: Public Works Bulletins #land C5 Permit Application Policy 99 -01 r cc: Justin Evans (P:Laurie Admin/Joanna/MBK Northwest 021805) t i i i t i i I f ,�1A'�: WM May 10, 2005 To: The City of Tukwila Public Works Department 6200 Southcenter Boulevard z Tukwila, WA 98188 -2544 Phone: 206 433 -1800 Fz From: Elite Commercial Contracting v U O' Dewaine Bednarik N o 804 West Meeker Street Ui Kent, WA 98032 N Phone: 253- 893 -3100 LL — O Re: Permit # D05 -049: Review # 1 dated 02/24/05 a_ Starbucks Coffee Company = d 17480 Southcenter Parkway _ Tukwila, WA CORRECTION . ? O. LTR# W W To Whom It May Concern: V 0, CO, ;O —: It is the intent of Elite Commercial Contracting in conjunction with Starbucks = Coffee Company to comply with Washington State Department of Health v requirements for protection of water supply systems. It is furthermore our intent F- — to install the required Reduced Pressure Principal Assembly (RPPA) with freeze Z protection as close as possible to the permanent water meter for this building. v N: For installation of the RPPA, Elite Commercial Construction will install under a O ~' Z separate Public Works permit. Elite will provide installation plans consisting of a schematic that clearly shows the location of the water meter, in relationship to the property line(s) and the building water meter size(s), water main connection and service to the property, together with a construction cost estimate to the Permit Center. It is the objective of Elite Commercial Contracting to comply with a financial guarantee of 150% of the project cost, estimated at 10,000 by Merit Mechanical and will be completed within 120 days of the date of this letter. RECEM Thank you for your attention and cooperation in this matter, CITY OF TUKMLA MAY 1 0 2005 PERMIT CENTER Dewaine Bednarik Vice President Elite Commercial Contracting �o5 -ov9 Bond No. 104442267 KNOW ALL BY THESE PRESENTS, That we Elite Commercial C Inc. Casua and Surety Company of America as Principal, and the Travelers as Surety, are held and firmly bound unto the City of Tukwila in the just and full sum of *Fifteen thousand three hundred seventy five and 00/100* ($ 15,375.00 ) Dollars, for which sum, well and truly to be paid, we bind ourselves, our heirs, executors, administrators, successors and assigns, jointly and severally, firmly by these presents. Sealed with our seals, and dated this 9th day of May 2005 THE CONDITION OF THIS OBLIGATION IS SUCH, that, whereas, the Principal has agreed to the completion of Installation of Reduced Pressure Principle Assembly (RPPA) with freez .Protection in Tukwil WA. NOW, THEREFORE, If the said Principal shall well and truly construct said improvements during the term thereof or any extension of said term that may be granted by Obligee with or without notice to the surety, then this obligation to be void; otherwise, to remain in full force and effect. Elite Commercial Contracting, Inc. (Principal) By Travelers Casualty and Surety Company of America (Surety) /f B l/( . R.A. Fix , , Attorney -In -Fact CITY OF TUKKWIU1 MAY 1 d 2005 .PERMIT CENTEIR s dos -ov9 -Z W JU U O; CO �. J to LL W J U. ?; CY ~W O . Z F-'. U� O D I-: W W' F- V O: ui Z U N'. X i O Z Apr.28, 2005 2:37PM 0 00 it Mechanical, Inc. No. 2501 P. 2 'DEWAINE BEDNARIK ELITE COMMERCIAL CONT INC 804 W MEEKER ST STE 201 KENT, WA 98032 -5702 PROPOSALm. 14016 Job Page 1 Merit Mechanical, Inc. PO Box 2109 Redmond, WA 98073 -2109 Phone (425) 883 -9224 Fax: (425) 867 -0962 04/28/2005 1 po # STARBUCKS TUKWILA 17480 SOUTHCENTER PKWY SEATTLE, WA 98188 phone (253) 893 -3100 JrU (253) 893 -3101 1Phone ( ) - 206 1 Fax ( ) - 206 1 This is a proposal to provide all labor, material, equipment, and permit to: A. Provide and install one Watts 2" 909 RPBA in a hot box within 18" of the customers water meter. The installation will be done per City of Tukwila specifications. Price includes: - Coordinating w/ the building property management company and building engineer for the purpose of shutting down the water to the complex while the changeover is completed. This will take approximately 5 hours to complete. - Excavation, backfill, trench cover, and safety barricades as required. Maximum excavation depth of 40 is allotted for in this bid. - Removal of the existing landscape plants and sod as needed. - Reconfiguring the irrigation supply piping as needed for the purpose of placing the new RPBA within 18 inches of the meter box. -Shop drawings and design drawings for permit submittal with the city. - Allowance of $325.00 for the cost of plan review and cost of permit. - Allowance of $500.00 for cost of landscape restoration. B. Provide and install one 1" water meter on the irrigation supply piping near near the water meter and after the newly installed RPBA, This meter to meet City of Tukwila specifications as written on the letter dated 2- 18 -05. Price includes: - Excavation, backfill, trench cover, and barricades as required. Maximum excavation depth of 40" is allotted for in this bid. RECEM - Installing the new meter at the same time the water line is changed to CITY OF TUIM accommodate the new RPBA. - Design and shop drawings for permit submittal with the city. MAY 1 Q 201 - Allowance of $275.00 for the cost of plan review and cost of permit. - Installation of a plastic meter box over the new water meter. PERMIT CEw In C. Exolusions and Conditions 1. Price excludes any modifications to the fire system backflow protection equipment. 2. Property management, tenants, and equipment owners will be responsible for all hutdown, securing, and restarting any water cooled equipment as needed. 3. Price excludes cost of electrical circuit to the hot box and any subsequent heat tape. 4. All new under ground piping to be Type "L" copper w/ closed cell insulation to protect it from the native soils. (Continued) z '►-' w JU 00 (00, W= J � N U. W O �Q CO D =d W F- _ Z� H O z 1_ UJ �5 U O c 0 F- W W F- ~. u. O 111 Z U _ H X, O z Dos -oY9 Apr, 28. 2005 2:37PM �it Mechanical, Inc, No, 2501 P. 3 PROPOSAL wo. 14 016 Pa 2 Merit Mechanical, Inc. PQ Box 2199 Redmond, WA 98073 -2409 Phone: (426) 883 -9224 Fax: (425) 8$7 -0962 TO 'DEWATNE BEbNARIK Date 04/28/2005 Po # ELITE COMMERCIAL CONT INC Job Name/ 804 W MEEKER ST STE 201 Location STARBUCKS TQKWILA SCENT, WA 98032 -5702 17480 SOUTHCENTER PKWY SEATTLE, WA 98188 Phona (253) 893 -3100 sax 1253)893 -3101 Phoaa ( } - 206 Fax ( ) - 206 5. Dewatering the excavations if required will be extra. 6. Price is based on back filling w/ native soil; export or import of fill is extra. 7. Price is based on working during normal business hours; after hours work will be extra. 8. Price excludes sales tax 9. Any work not specified in the scope above will be extra. All additional, costs will be authorized in writing before continuing work. CITY OF KKWIL.A MAY 1 0 2005 PERMIT CENTER Ten Thousand Two Hundred Fifty Dollars and 00 slants $10,250.00 Payment to be made as follows: MONTHLY PROGRESS BILLINGS NET 30 DAYS, FINAL BALANCE NET 30 DAYS PROM INVOICE; 1 3/43 INTEREST CHARGED MONTHLY ON ALL PAST DUE AMOUNTS. 107 §X 020 -X3111 WXR ON ALL W Od704Ci9 N IP AND MTE IALS. MMUMCT0435 WILZ ANDY ON Authorized ALL EQV17MM'NT 'WS. VALV85. AND COMOLS. NO NA ON ANY MATYRIALS OR SQUI -PHIOT PROVIDED ST Or'MS. NO WX-LU TY ON AN- MCIST_NO EQV1rC3NT, Signatur® ?2���Pe ea-�O� MMING. ? SYS -MM, PUN25. OR CONTROLS. Submitted By: Sco t MacEolman Notes This proposal may be withftawn by us if not aoc"ted within 45 days Acceptance of Proposal Signature Date of Aaeeptance: Print Name oY9 Z Z W 0t 2 . 00 (D o CO) LL, W O }F �J LL Q � d �W F- O. Z !- 5 U� O N: .0 H W Z I-- U. •• Z W , O f-: Z City of Tukwila FED 2 4 2005 Department of Public Works [y: February 18, 2005 MBK Northwest 2401 Utah Avenue South, #800 Seattle, WA 98134 Steven M Mullet, Mayor ztn es F. Morrow, P.E., Director 1 # RE: Starbucks Coffee Company r E Tenant Improvement L, 17480 Southcenter Pkwy, Tukwila WA MAY 1 0 2005 Permit No. D05 -049 PERMIT CENTER To Whom It May Concern: s In accordance with Washington State Department of Health guidelines for Group A Public Water Systems, Public Works has implemented a cross - connection control program to protect the public water system from contamination via cross - connection. The program requires elimination or control of any cross - connection between the distribution system and a consumer's water system by the installation of an approved backflow device. Since this project includes alterations to the existing plumbing system, i i the entire plumbing system must be brought up to the current standards as set forth in the Uniform ! Plumbing Code including installation of an approved backflow prevention on the fire line, irrigation line and the water supply to the building. The City has determined that the building at the above address has deficiencies on the domestic water supply and landscape irrigation. a) Domestic Water A Reduced Pressure Principle Assembly (RPPA), previously called a Reduced Pressure Backflow Assembly (RPBA), shall be installed immediately downstream of the permanent water meter. Installation at another location requires the Public Works Director's approval. The RPPA shall be installed in a Hot Box or equal freeze protection enclosure anchored to a. minimum 4" thick concrete pad. Public Works highly recommends a power supply be provided for the Hot Box. b) Landscape 17Wgation The existing irrigation deduct water meter shall be upgraded with a Sensus ECR -WP register that is ! compatible to the Invensys automatic reading system and register ring. The Public Works Director will withhold issuance of Starbucks Coffee Company Tenant Improvement permit until the Permit Center receives plans for installation or a bond for installation of an RPPA on domestic water and upgrade of irrigation water meter. Z W' ug D o O' cf)o J � �LL w LL = CY w Z �. Z O. �p 0—. o F- w u_ ui Z F= _ O~ z j)OSO -ot�9 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 -433 -0179 • Fax: 206- 431 -3665 I MBK Northwest Page February 18, 2005 o 'r If you opt to install, you may install under a separate permit or under a revision to the Tenant Improvement permit D05 -049 application. If you opt to install under the Tenant Improvement permit, you must supply the installation plans consisting of a schematic that clearly shows the location of the irrigation deduct and domestic water meters in relationship to the property line(s) and the building, sizes of all water meters, connections to the water main, and service to the property together with a construction cost estimate to the Permit Center as a revision to the Tenant Improvement permit application. RPPA installation and irrigation modifications will trigger a Public Works Type C Construction Permit, which has a progressive fee. For a Type C permit, Public Works collects a base application and plan review fee ($250.00 plus 2.5 % of construction cost for RPPA installation and irrigation modifications) when the application or revision to this TI is submitted. An additional 2.5 % of construction cost for RPPA installation and modifications to the irrigation system will be assessed at the time of permit issuance. If you opt to bond for the installation, you must provide the following to the Permit Center: 1) an original design and installation estimate, 2) a bond for 150 % of the design and installation cost, and 3) a letter stating your intent to install the backflow and modify fire and irrigation systems by a certain date. This must be done before the Permit Center issues the permit I have enclosed Public Works Bulletin 1 to help you. Please call Mike Cusick, Public Works Senior Water and Sewer Engineer, at (206) 431 -2441, or Jim Morrow, Public Works Director, at (206) 433 - 7161, if you have any questions. Sincerely, Joanna Spencer Development Engineer JS:lw enclosures: Public Works Bulletins #land C5 Permit Application Policy 99 -01 cc: Justin Evans (P:Laurie Admin/Joanna/U3K Northwest 021805) FIECEM CITY OF TUKMLA MAY 1 0 2005 PERMIT CENTER dos -oyq Z Z �w 2 �D J U. U (0 U: CO W J H CO) U W O. 9 Ei U¢ CO d' = w z F.. Z W D' D CX o CO' C 3 = U� LL � 0 ui Z , U o Z . -r 1 - 1 I �I -aa► 3 City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director Mr. Justin Evans 804 West Meeker Street Kent, Washington 98032 RE: CORRECTION LETTER #1 Development Permit Application Number D05 -049 Starbuck's Coffee Company —17480 Southcenter Parkway Dear Justin: This letter is to inform you of corrections that must be addressed before your development permit(s) can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Public Works Department. At this time, the Building, Planning and Fire Departments have no comments. Public Works Department Joanna Spencer, at (206) 431 -2440, if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) complete sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. Z �Z Cr.W JU 00 co D CO LU W = N u. L L co) = C! H= Z Z o. U D:. 0D. D F— w w U —O Z , U CA; :O Z.. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the or by athe mail or by a messenger service. If you have any questions, please contact me at (206) 433 -7165. Sincerely, i Stefania pencer Permit Technician encl xc: File No. D05 -049 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 _5 (.j C� E f ZI 0 PUBLIC WORKS DEPARTMENT COMMENTS DATE: February 18, 2005 PROJECT: Starbucks Coffee Company PERMIT NO: D05 -049 Z z W PLAN REVIEWER: } Contact Joanna Spencer at (206) 431 -2440 if you have any U1 7- questions regarding the following comments. 0 Co 0 1) Since this project includes alterations to the existing plumbing system, the entire plumbing W X system must be brought up to the current standards as set forth in the Uniform Plumbing cn LL , Code including installation of an approved backflow prevention on the fire line, irrigation W O, line and the water supply to the building. The City has determined that there are �a deficiencies on the domestic water supply line and irrigation line. LL d a) Domestic Water Z UJ. A Reduced Pressure Principle Assembly (RPPA), previously called a Reduced Pressure F . 0 Backflow Assembly (RPBA) shall be installed immediately downstream of the existing w w permanent water meter. Backflow installation at another location requires the Public o' Director's approval. The RPPA shall be installed in a Hot Box or equal freeze o cn; protection enclosure anchored to a concrete pad. A power supply is highly ° �- recommended for the Hot Box. 0 ~O U- b) Landscape Irrigation w Z The existing irrigation deduct water meter shall be upgraded with a Sensus ECR -WP U to register that is compatible to the Invensys automatic reading system and register ring. z ~ I have enclosed Development Bulletins C5 that spells out design and installation requirements for cross connection control and Al and A2 that summarizes Public Works permits and fees. Please note that a separate letter was mailed to the building owner, MBK Northwest. The Public Works Director will withhold issuance of this Tenant Improvement permit until the Permit Center receives plans for items (if applicable) la and lb or a bond for 150% of the design and installation cost of subject devices, together with a letter stating the installation by a certain date. (P:Laurie Admin/Joanna/Comments D05 -049) PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D05 -049 DATE: 02 -14 -05 PROJECT NAME: STARBUCKS COFFEE COMPANY SITE ADDRESS: 17480 SOUTHCENTER PARKWAY X Original Plan Submittal _Response to Incomplete Letter # Response to Correction Letter # Revision # after /before permit is issued DEPARTMENTS �n> I Z',S 'a� �51( Buil ing Ivlsion Q Fire Preven ion Q Public Wor E1, Structural ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete ❑ Comments: P a n ' ���� A/ % Pning Division Permit Coordinator DUE DATE: 02 -1 5 -05 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS R TING: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS Approved ❑ Approved with Conditions ❑ Notation: REVIEWER'S INITIALS: N1 DUE DATE: 03 -15 -05 Not Approved (attach comments) DATE: Permit Center Use On /y CORRECTION LETTER MAILED: ca-c- -5' Departments issued corrections: Bldg E Fire ❑ Ping ❑ PW19 Staff Initials: sa g t 9 *4 y C OPY Documentslrouft sllp.doc z -28 -oz ❑ No further Review Required DATE: z z �w D JU UO W J = H � w O ga_j U. ?. U)d �w z �. �O w ~ w U� O - 0 H wW L lIJ Z' z } PLAN REVIBIVROUTING SLIP ACTI VI TY N U M BER- D05-049 DATE 05/10/05 PROJECT NAME Starbucks Coffee Company SI TE AD D REST 17480 Southcenter Pkwv Original Plan Submittal __Response to Incomplete Letter# Response to Correction Letter # 1 Revision # _ After Permit Is Issued D EPARTM ENT& Building Division ❑ Fire Prevention ❑ Planning Division ❑ Public Wo s� Structural ❑ Permit Coordinator DErE MINATION OFCOMPLErENESS (Tu Thurs.) DUEDATE 05/12/05 Complete Id Incomplete ❑ Not A p plicable 1:1 Comments: Fkwmit Center Use Only INCOMPLETE LETTER MAI LID: LETTER OF COM PLETEN ESS MAI LID: Departments determined incomplete: Bldg ❑ Fire ❑ Fing ❑ PW ❑ Staff Initials TUMHURSROU G: Please Route Structural Review Required ❑ No further Review Required ❑ REVI NERSINITIALS DATE APPROVALS OR CORRECTION& DUEDATE 06/09/05 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ N otati on: REVIBNERS INITIALS DATE Permit Center Use Only COATI O N LETTER MAILED: Departments issued corrections Bldg ❑ Fire ❑ Fing ❑ PW ❑ Staff Initials: Documents/routing dip.doc i 2 -28 -02 z I ~ iW W, JU Uo LU J N LL W O LLQ �d = w z� I- o z �- LLI 5. U° O CO .o H- W NU LL -- z U N O z City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: ht(p:! /www.cLtukwila.wa.us ! '�'"`4 Steven M. Mullet, Mayor Steve Lancaster, Director REVISION SUBMITTAL j a Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date.. G . 10 . 0 � ❑ Response to Incomplete Letter # Plan Check/Permit Number: rte- y S " D4 't [� Response to Correction Letter # I ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: S'T A23�►c,�S �CE� ow•PPa� y Project Address: 1'1 `i� S• --�rM c- �N'�e +Ls -yc�,, ��'�. �+� `,o�. Contact Person: , - 5, 'T I P-5 E' -Jr+.+S Phone Number: Z Summary of Revision: t 2 --T a12QC —c,ci� c.-Zrc.zow-o, Re RPPA yp►%.uc t r.► S -- f-jk_ E '�....r� + cra t e 9 - V0aJz C -% �t:) c,.-. e I es o = oart L.FW1WX oV t. •5�..�� '3ors� i� d.�o - tE CfiY OF TUKMLA Sheet Number(s): "Cloud" or highlight all areas of revision including date of ' re ) vision Received at the City of Tukwila Permit Center by: /, &/ d Entered in Permits Plus on ()5 # Q- pp ications onus- applications on Ime evision submittal Created: 8 -13 -2004 Revised: Z '~ W U. UO U) o . W =. N LL ,w LLQ CO D = �. w z� F- O w ~ W U� 0 Cl) o E- w W' LL lJJ Z U= O Z - '1N3Wf10oa 3H1 = iO Jll1 yno 3H1013f1a Sl 1130110N SIHl NVH.Lad310 SS31 SI 3WVH=l SIHl NI 1N3wnooa_3H1_ -41 :3011ON" ----- ---- - f DEPARTMENT OF LABOR AND INDUSTRIES I REGISTERED AS PROVIDED BY LAW AS j CONS,T _GENERAL. REGIST # EXP: DATE- YCCO1 ELITECCO20CD;02 /06/2007 EFFECTIVE DATE ^ 02/04/1998 ELITE COMMERCIAL CONTRACTING 804 WEST MEEKER STREET KENT WA 98032 F625- 052 -000 (8/97) ( Detach And Display Certificate l REGISTERED AS PROVIDED BY LAW AS CONST CONT GENERAL Please Remove REGIST . # EXP . DATE And Sign CC01 ELITECCO20CD 02/06/2007 Identification EFFECTIVE DATE, 02/04/1998 Card Before ELITE COMMERCIAL CONTRACTING Placing In 804 .WEST MEEKER. STREET Billfold KENT W r9o 2. SiOlUtUre Issued by DEPARTMENT CIF LA OR AND INDUSTRIES F625 -052 -000 (8/97) \ N N S GpN►Miss� � + +, Qy .... .. _.. .,. .�. r.... -.. «.. -- 'na. +. .r.. ,. > -.. ._ :,.m.....t �,`. i. �;;..: 2Z:. �v:=]'. z.:, = «. �.-..: K,: �ezc: mac�u:. �. u•• raseea. m.:,• .�...- ...:e<+�•.�.7- T- . -.<u.. _ ,..,k_.e. -"... . " ..T...- ..- .�- . - ,_.�.ox_'- ,.:... �.c+- ...r < >s-. ... .a1- -... >„ .,. z ----- ---- - f DEPARTMENT OF LABOR AND INDUSTRIES I REGISTERED AS PROVIDED BY LAW AS j CONS,T _GENERAL. REGIST # EXP: DATE- YCCO1 ELITECCO20CD;02 /06/2007 EFFECTIVE DATE ^ 02/04/1998 ELITE COMMERCIAL CONTRACTING 804 WEST MEEKER STREET KENT WA 98032 F625- 052 -000 (8/97) ( Detach And Display Certificate l REGISTERED AS PROVIDED BY LAW AS CONST CONT GENERAL Please Remove REGIST . # EXP . DATE And Sign CC01 ELITECCO20CD 02/06/2007 Identification EFFECTIVE DATE, 02/04/1998 Card Before ELITE COMMERCIAL CONTRACTING Placing In 804 .WEST MEEKER. STREET Billfold KENT W r9o 2. SiOlUtUre Issued by DEPARTMENT CIF LA OR AND INDUSTRIES F625 -052 -000 (8/97) \ N N S GpN►Miss� � + +, Qy .... .. _.. .,. .�. r.... -.. «.. -- 'na. +. .r.. ,. > -.. ._ :,.m.....t �,`. i. �;;..: 2Z:. �v:=]'. z.:, = «. �.-..: K,: �ezc: mac�u:. �. u•• raseea. m.:,• .�...- ...:e<+�•.�.7- T- . -.<u.. _ ,..,k_.e. -"... . " ..T...- ..- .�- . - ,_.�.ox_'- ,.:... �.c+- ...r < >s-. ... .a1- -... >„ .,. pr File: D05 -0049 35m m Drawing #1 -8 pr fififfl- LOADING I I I I I I I I I I I I I I I I I I I I F] I 160' 55' . .uuuxl _ 11 55' U. I I T L N zN r STORAGE . 6,865 S. F. e . GART L DD .sPo.rts N 40,000 S.F. I U N.AVY ST R B U KS 2R82 SF, 125' U U U U U n n 0 n U U U U U 70' 30' H+f+ ZLL F ro L W c W . CO 1r^ co U U RETAIL CL LL: Z 5,600 S. F. o IM N IL m Il 38,500 S. F. Q C� 71- )-� ( . J-) 29,200 S.F. R®STROOMS .o C W zLL -� (Ij CD U) Cr) Z z e . H+f+ ZLL F ro L W c W . CO 1r^ co U !r ce�oladon of any of approved H@ Go cc c ccl �I c c c c C c c c J c C C C �/ � SoU � MC EN��R SEPARATE PERMIT REQUIRED FOR: Mechanical I� Electrical t Plumbing Gas Piping C4 Of Tukwila KING DIVISION I sbW to emors and Ion dImmou does(not 0.S 1 0 *)1 k �fi 1� oi- Starbucks Coffee Company 2401 Utah Avenue South Suite 800 Seattle, WA 98134 206 - 318 -1575 Starbucks Parkway Supercenter 17500 Southcenter Parkway Tukwila, WA 98188 Starbucks Store # 3267 RENOVATION Site Plan Scale: 1" = 60' N REVIEWED FOR CODE ComPLIA CE MAY 1 �. X005 Site Plan Scale 1" = 60 Created: Page 2/11/05 1 of 1 F.H. C of 7UWla BUILDING DM M .- :K ",..� _ SITE P LAN iil.I�.l,ll.l.l.�il ill I(I ICI I(I I ITIIIlI I)I i(Thl(I 1�1 III I(1, Ill �I� �ji I(I IjI t � _ Inch vts u ,� NA 7l �m� 5 61 ft ♦ i � �` ( S. l r . II I l I I I I I Ll�.l -!LI I LI ll.�.11LIIJ.LLI� I LIILLI I L� LI_I I I I LI l.! -! (! L�.l.l I I �I IJ (l.l.11 l�ialLl I I I,i �.I,lI I I I [L�LLI - I I I LI�L� � I II I LI � I I I I I I I I I � I I I I I , 165' F N • ABBREVIATIONS: STARBUCKS COFFEE COMPANY A3.0 GENERAL NOTES: ACC ACT ACCESSIBLE ACOUSTICAL CEILING TILE HORZ HR HORIZONTAL HOUR I. AFTER STARBUCKS ACCEPTS THE BID FROM THE GENERAL CONTRACTOR (GC), F ADJ ADJUSTABLE HVAC HEATING VENTILATING THE GC HAS NOT ALREADY DONE SO FOR A PRIOR JOB, THE GC SHALL REVIEW AFF ABOVE FINISHED FLOOR 1 A0. AIR CONDITIONING AND EXECUTE STARBUCKS AGREED TERMS AND CONDITIONS FOR REMODEL ALUM APPROX ALUMINUM APPROXIMATE HW HOT WATER CONSTRUCTION PROJECTS ( "TERMS AND CONDITIONS') AND FOLLOW ITS REQUIREMENTS. BLXG BLOCKING ID IF INSIDE DIAMETER 4 BOB BOTTOM OF BEAM INSIiL INSIDE /INTERIOR FACE INSULATION 2. GC SHALL VISIT THE SITE, REVIEW THE BUILDING SHELL DRAWINGS AS SUBMITTED BLDG BUILDING INFO INFORMATION BY THE LANDLORD OR STARBUCKS SITE SURVEYOR, AND BECOME THOROUGHLY CAB CABINET JC JOB CAPTAIN FAMILIAR WITH THE SITE CONDITIONS PRIOR TO BIDDING OR CONSTRUCTION. CLG CLR CEILING CLEAR/CLEARANCE LL MAX LANDLORD MAXIMUM 3. GC SHALL CONSULT WITH STARBUCKS CONSTRUCTION MANAGER (CM) TO RESOLVE CMU CONCRETE MASONRY UNIT MEC1 MECHANICAL ANY CHANGES, OMISSIONS OR PLAN DISCREPANCIES PRIOR TO BIDDING OR CYR C.L. CENTER CENTER LINE MC MECHANICAL CONTRACTOR CONSTRUCTION COL COLUMN MEP MECHANICAL ELECTRICAL 4. FOR EACH PROJECT GC SHALL SUBMIT TO STARBUCKS CM AN EXECUTED PROJEC CONC CONCRETE AND PLUMBING REMODEL CONSTRUCTION CONTRACT PRIOR TO STARTING CONSTRUCTION. CONT CONTINUOUS WG MANUFACTURER CONST CONSTRUCTION MIN MINIMUM 5. GC SHALL COORDINATE AND MANAGE ALL PORTIONS OF THE WORK AS DESCRIBED CT CERAMIC TILE MIDG MOULDING IN THE CONTRACT DOCUMENTS, WFNICH INCLUDE, BUT ARE NOT LIMITED T0, CW COLD WATER MRL NAT METAL NATURAL THE TERMS AND CONDITIONS, CONSTRUCTION SPECIFICATIONS, DEG DEGREES NIC NOT IN CONTRACT ARCHITECTURAL. DRAWING AND MECHANICAL AND ELECTRICAL DRAWINGS. DTL DIA DETAIL DIAMETER OA NOT TO SCALE ALL 6. ALL WORK SHALL BE PERFORMED IN STRICT COMPLIANCE WITH LOCAL, COUNTY, DIM gdSP DIMENSION gbS ENSER OC ON CENTER STATE AND FEDERAL. CODES AND ORDINANCES. DWG(s) DRAWING(S) O OUTSIDE DIAMETER 7. GC SHALL VERIFY THE LOCATION OF ALL UTILITIES. EA EACH OPNG OPENING 8. GC TO VERIFY ALL DIMENSIONS, INCLUDING CLEARANCES REQUIRED BY OTHER EC ELECTRICAL CONTRACTOR PC PLUMBING CONTRACTOR TRADES, AND NOTIFY STARBUCKS CM OF ANY DISCREPANCIES PRIOR TO ELEY ELEVATION PLAM PIYWD PLASTIC LAMINATE* PROCEEDING WITH THE WORK.ALL DIMENSIONS ARE TO THE FACE OF THE FINISHEE ELEC ELECTRICAL PM PLYWOOD PROJECT MANAGER SURFACE UNLESS NOTED OTHERWISE. ALL DIMENSIONS TO BE TAKEN FROM EOUIP EOUIPMENT PT PAINT DESIGNATED DATUM POINT.DO NOT SCALE DRAWINGS. ED E/S EOUAL EG -SHEL OT R OUARRY TILE RADIUS 9. GC SHALL PATCH AND REPAIR ALL EXISTING WALLS, FLOORS, CEILINGS OR OTHER EXIST EXISTING RCM RENOVATIONS CONSTRUCTION SURFACES IDENTIFIED TO REMAIN THAT MAY BECOME DAMAGED DURING THE EXP EXPOSED MANAGER CO OF THE WORK. EXT FFE EXTERIOR FINISH FLOOR EIEV REF REGVO) REFERENCE REOUIRE(D) 10. TIRE GC IS RESPONSIBLE FOR OBTAINING PERMITS FOR FIRE PROTECTION, FOE FACE OF CABINET REV REVISED/REVISION PLUMBING, MECHANICAL AND ELECTRICAL. SYSTEMS PRIOR TO INSTALLATION OF FOG FACE OF GLAZING SC SOLID CORE SUCH SYSTEMS, FOS FRP FACE OF STUD FIBERGLASS S/G SEMI -GLOSS 11. GC SHALL RETAIN ONE SET OF THE PLANS TO NOTE AND DOCUMENT ALL RET ER G LASS PANEL SHY SHEET CHANGES DURING CONSTRUCTION. THIS SET SHALL BE DELIVERED TO STARBUCKS FIO FURNISHED d INSTALLED SIM SOL SIMILAR SOLID CM UPON COMPLETION OF THE WORK. FOIL BY OWNER FURNISHED BY OWNER SPECS SPECIFICATION(S) 12. G.C. IS RESPONSIBLE FOR COORDINATING DELIVERY OF MATERIALS FROM INSTALLED BY CONTRACTOR so SOUARE STARBUCKS CONTRACTED THIRD PARTY LOGISTICS (3PL) DISTRIBUTION SERVICES FLR FLOOR SF Ss SQUARE FEET AND VENDOR DIRECT (VD) SHIPMENTS. REFER TO STARBUCKS CM FOR METHODS FT FOT/FEET STL STAINLESS STEEL STEEL AND LEAD TIMES. FV GA FIELD VERIFY GAUGE STG STORAGE 13. RESPONSIBILITY FOR SUPPLY AND DELIVERY OF MATERIALS AND EQUIPMENT IS GALV GALVANIZED SUSP SUSPENDED IDENTIFIED IN THE SCHEDULE DRAWING SHEETS (SC.1, SC.2, A SC.3) UNDER! THE GC GENERAL CONTRACTOR TEL TEMP TELEPHONE TEMPORARY COLUMN LABELED "SNP ". "GC" MEANS THE ITEM IS TO BE SUPPLIED BY THE G.C. "3PL" G GYPSUM WALL BOARD TYP TYPICAL MEANS AN ITEM IS SUPPLIED BY STARBUCKS VIA STARBUCKS CONTRACTED HC HOLLOW CORE URN UNLESS OTHERWISE NOTED DISTRIBUTION SERVICE AND "VD" MEANS SUPPLIED BY STARBUCKS AND SNIPPED HDR HEADER VET VINYL COMPOSITE TILE DIRECTLY TO THE SITE FROM THE VENDOR. HDWD HARDWOOD VERT VERTICAL HDWR HM HARDWARE HOLLOW METAL V1F VERIFY IN FIELD WH WATER HEATER WD WOOD FLOOR PLAN: 1/4" = 1 1 — o-- 7 M09Y THROUGHOUT BACK L�—� HOUSE WHERE NECESSARY WORKROOM S A LES LEGEND: ® NEW WALL CONSTRUCTION r... ___.�. EXISTING TO BE REMOVED EXISTING TO REMAIN . • . • . • . CENTER LINE 0 REVISION CLOUD / I t 1 1 1 0 -VLF`%" SCALE BAR 6' -7Yi° DIMENSION LINE FROM FINISH FACE TO FINISH FACE 0 �•-' ' .. . W 3 FW9 Pl*7 ESTROOM V ST �„.,.. �� ✓ h 6 MOW r"`. - h` `' "` TYP. THROUGHOUT FRONT 4 OF HOUSE WHERE NECESSARY ry •t �•,.• E.'::: ::' � � "*,r i� .`'•`.+/' ..K • •t •.• • i . . ,� • `�• SEATING ADLI A6.1 ol REPAIR AND MAINTENANCE: AO TOUCH UP EXISTING WOODWORK THROUGHOUT, TO INCLUDE CASEWORK AND WAINSCOT. REMOVE ALL SCRATCHES, SCRAPES, AND BLEMISHES, STAIN TO MATCH EXISTING WOODWORK FINISHES, SEE SHEET SCI FOR EXISTING FINISHES. © REPLACE ANY DAMAGED OR BROKEN EXISTING TILE THROUGHOUT THE STORE AS REQUIRED. FILL IN GROUT LINE DEFICIENCIES. SEE SHEET SCI FOR EXISTING FINISHES. © REPLACE ANY DAMAGED CASEWORK AS REQUIRED, INCLUDING RELAMINATING COUNTERTOPS OR CABINET FACES, REPLACING DEFECTIVE DRAWER GLIDES, AND REPAIRING CABINET DOORS, HINGES, III PULLS. FLOOR PLAN NOTES Q SEE SCI FOR FULL SCHEDULE OF ALL COMPONENTS OTHER THAN CASEWORK. �2 RELOCATE EXISTING BREWING EQUIPMENT. O3 RELOCATE EXISTING BLENDERS, PROVIDE POWER FOR FOUR BLENDERS. 40 ITEMS TAGGED ON SHEET All. 8 NEW CHAIR RAIL FINISH TO MATCH EXISTING. 6 INSTALL CLEAR CORNER GUARDS AS INDICATED. MOUNT AT 6" AFF. BACK-PAINT W1TW SL OW CHAIR RAY!" AT APPLICABLE LOCATIONS. R DO�NOT INSTALL CORNER GUARDS ABOVE CHAIR 7O INSTALL METAL CORNER GUARDS AS INDICATED. MOUNT AT 6" AFF. AFFIX WITH 06 STAINLESS S TEEL OVAL Z" O.C. OFFSE ON FROM ' EITHER SIDE %2" VERTICALLY. REPLACE ALL PREVIOUSLY ISSUED SHEETS. PROJECT INFORMATION: MAI WP+ ADDRESS- STARBUCKS COFFEE COMPANY A3.0 2401 UTAH AVENUE SOUTH T • NORTH ARROW A6.0 FINISH SCHEDULE A6.1 BENCHMARK STORE PI.ANNER/DESIG ER- REVISION FINISH SCHEDULES SECTION NUMBER $ DATUM POINT 1 A0. SECTION +X' -XX" AFF HEIGHT TAGS 2 SHEET NUMBER ® DOOR NUMBER 1 0 3 ELEVATION O EQUIPMENT TAG 4 bETAIL AMBER <0 WAIL TYPE TAG i AO.O DETAIL BUBBLE Q APPLIED WALL WORKSINK TREATMENT TAG 1 SHEET NUMBER .. SCOPE OF WORK TAG ® NEW WALL CONSTRUCTION r... ___.�. EXISTING TO BE REMOVED EXISTING TO REMAIN . • . • . • . CENTER LINE 0 REVISION CLOUD / I t 1 1 1 0 -VLF`%" SCALE BAR 6' -7Yi° DIMENSION LINE FROM FINISH FACE TO FINISH FACE 0 �•-' ' .. . W 3 FW9 Pl*7 ESTROOM V ST �„.,.. �� ✓ h 6 MOW r"`. - h` `' "` TYP. THROUGHOUT FRONT 4 OF HOUSE WHERE NECESSARY ry •t �•,.• E.'::: ::' � � "*,r i� .`'•`.+/' ..K • •t •.• • i . . ,� • `�• SEATING ADLI A6.1 ol REPAIR AND MAINTENANCE: AO TOUCH UP EXISTING WOODWORK THROUGHOUT, TO INCLUDE CASEWORK AND WAINSCOT. REMOVE ALL SCRATCHES, SCRAPES, AND BLEMISHES, STAIN TO MATCH EXISTING WOODWORK FINISHES, SEE SHEET SCI FOR EXISTING FINISHES. © REPLACE ANY DAMAGED OR BROKEN EXISTING TILE THROUGHOUT THE STORE AS REQUIRED. FILL IN GROUT LINE DEFICIENCIES. SEE SHEET SCI FOR EXISTING FINISHES. © REPLACE ANY DAMAGED CASEWORK AS REQUIRED, INCLUDING RELAMINATING COUNTERTOPS OR CABINET FACES, REPLACING DEFECTIVE DRAWER GLIDES, AND REPAIRING CABINET DOORS, HINGES, III PULLS. FLOOR PLAN NOTES Q SEE SCI FOR FULL SCHEDULE OF ALL COMPONENTS OTHER THAN CASEWORK. �2 RELOCATE EXISTING BREWING EQUIPMENT. O3 RELOCATE EXISTING BLENDERS, PROVIDE POWER FOR FOUR BLENDERS. 40 ITEMS TAGGED ON SHEET All. 8 NEW CHAIR RAIL FINISH TO MATCH EXISTING. 6 INSTALL CLEAR CORNER GUARDS AS INDICATED. MOUNT AT 6" AFF. BACK-PAINT W1TW SL OW CHAIR RAY!" AT APPLICABLE LOCATIONS. R DO�NOT INSTALL CORNER GUARDS ABOVE CHAIR 7O INSTALL METAL CORNER GUARDS AS INDICATED. MOUNT AT 6" AFF. AFFIX WITH 06 STAINLESS S TEEL OVAL Z" O.C. OFFSE ON FROM ' EITHER SIDE %2" VERTICALLY. REPLACE ALL PREVIOUSLY ISSUED SHEETS. PROJECT INFORMATION: MAI WP+ ADDRESS- STARBUCKS COFFEE COMPANY A3.0 2401 UTAH AVENUE SOUTH All MS STOP- S -SD2 A6.0 SEATTLE, WASHINGTON 98134 A6.1 (206) 447 -1575 STORE PI.ANNER/DESIG ER- WARREN PHILLIPS FINISH SCHEDULES (206)'318 -4032 PHONE CABINET - 24" (206) 318 -1776 FAX RENOVATIONS GARY NEWMAN CONSTRUCTION MANAGER- (206) 908-8224 X2220 PHONE BREWER (29'• AFF) (206) 318 -2591 FAX LANDLORD MBK NORTHWEST Q `� 7690 SW MOHAWK STREET TRASH DROP TUALATIN, OR 97062 1 503 684 -7272 FAX U WW STARSUOR CaroUn M STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH, SUITE 800 SEATTLE, WASHINGTON 98134 (208)318 -1575 TWX MJM ILO SKOI1CATR-/a. AS ML AS STARKOWK%9 NO LOCO. TRAMMMM ao DEN" ARC TIC D mLWVt PRwom or STARKOM CalORAmK /M• Kmwm CT m MWFXAMN. OaCLO M mWOR UX or THM MATLRMLS IOM Illy PO R7" of T-CM1 SRIMOIR STIIU"OI T_ worm Comm a sTlecTLr rRalertm. APPROVAL STAMPS: — I INDEX OF SHEETS: I A1.0 PROJECT INFORMATION/ SCOPE OF WORK A3.0 DEMOLISH PLANS All CONSTRUCTION, REFLECTED CEILING PLANS A6.0 INTERIOR ELEVATIONS A6.1 INTERIOR ELEVATIONS SIMEOM SCI COMPONENTS SCHEDULES SC2 FINISH SCHEDULES c � �0,46 Fp��� MFR �• � M ay � � ( + & CASEWO K SPONSOLITIES LEGEND e D FINISHED BY AL CONTRACTOR. MATCH - ADJACENT CASEWORK FINISHES. SEE EXISTING FINISH SCHEDULE, A.' �" \a� SHEET SC.2. PROVIDED AND FINISHED BY STARBUCKS CASEWORK VENDOR. SEE NEW FINISH SCHEDULE, SHEET SC.2. I rlllI ill�lll il'i�l`)Ilil���l��i� atil�l�l�l �I� li�l� Inch 1118 ... {■, 5L ti EL ZL 0 j• �a: �. �. �. 1L1. IJ - I 6 1 .. II�LI I�III�IIII. I�IIaIIIIII�IL�IIIILL�ll1I( �IL��. I- �I, �J�1�� .1_IL�ILLI:�_l�ILLI_I�I���II I)', VI [FI �iI'5ii `IIi1iliili+II6I, 1. <•. 'Qa 1'�:a�Il�ls•���ifl �� ) Z b w� LII;I �l,1II ' I III�1 1 �llllll ll�ljllll �����111111111�IIIII. CASEWORK SCHEDULE: F EM QTY I DESCRIPTION OPFPATInuC C140 1 CONDIMENT TOP - C621 21.94 SOLID SURFACE C230 1 CABINET - 16'• C678 3 HANDSINK C233 1 CABINET - 24" C237 2 CABINET - 36" BREWER (29'• AFF) C240 1 SS TOP - 16'• Q `� / TRASH DROP C246 1 SS TOP - 16 IN =Q HAND SINK C250 1 SS TOP - 24 IN WORKSINK C253 1 SS TOP - 72 IN V BREWER C258 3 UPPER FILLER KIT - 12•• C260 7 UPPER WALL CABINET - 30" C261 3 SOFFIT FASCIA - 14 "X96'• C262 3 SOFFIT VALANCE - 3 "X96'• C288 1 CABINET - 16•• TRASH C C C C WAI I G /TRI" VDt ADDITIONAL ITEMS ADL1 1 WAINSCOT WITH VINYL TRIM CONSULTANTS REV DATE JC DESCRIPTION &/11/05 CASEWORK REVISION BY O.L. STORE NUMBER 3267 PHONE NUMBER: 208575 -1774 2036 Q C621 21.94 CHAIR RAIL - JC: DAVID LIU 3 -1/2 C678 3 BB WALL PLAM - 0 W OLIVE ORCANIX C682 4 WALL PLAM - OLIVE ORCANIX VDt ADDITIONAL ITEMS ADL1 1 WAINSCOT WITH VINYL TRIM CONSULTANTS REV DATE JC DESCRIPTION &/11/05 CASEWORK REVISION BY O.L. STORE NUMBER 3267 PHONE NUMBER: 208575 -1774 PROJECT NO. 03267 -044 SQ. FT: 2036 Q 11 JAN 2005 z V JC: DAVID LIU CHECKED: w 0 W a - a ~ :3 woo v— Q `� / Z W� Q =Q 0 m 0 Z W Er. V Q �� F Y 0 IL U PROJECT NO. 03267 -044 SQ. FT: 2036 ISSUE DATE: 11 JAN 2005 PM: WARREN PHILLPS JC: DAVID LIU CHECKED: MARK MEADOWS SCALE: NO SCALE (DO NOT SCALE DRAWINGS) SHEET TITLE PROJECT INFORMATION / SCOPE OF WORK A1.0 pr 0 DEMOLITION RCP /SOFFIT DEMOLITION FLOOR PLAN OUTDOOR SEATING GENERA!. NOTES O DEMOLITION TO MEAN REMOVAL. AND OFF SITE DISPOSAL OF DEMOLISHED MATERIALS. REMAINING SURFACES TO BE RESTORED TO ACCEPTABLE CONDITION. O IF DURING DEMOLITION CONDITIONS ARE REVEALED THAT MAY JEOPARDIZE INTEGRITY OF STRUCTURE OR PRECLUDE FOLLOWING DESIGN INTENT, GC TO NOTIFY STARBUCKS RCM IMMEDIATELY. © GC RESPONSIBLE FOR SITE INVESTIGATION PRIOR TO DEMOLITION TO REVEAL FULL SCOPE OF WORK. DEMOLITION RCP NOTES U ioo] STARKOM Coffl GMT M STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH, SURE 800 SEATTLE, WASHINGTON 98134 (208)318 -1575 STMOUCKV MAW 'ZL joo= TRmmx rem me Mum MC 7m EXCLLmn PROP", v of STMOUCKS CCR►OItAML MM RDOODUCTM TMd[ LVDMAUKDOMPSURE µ0 PORTTlOM OF TOo IrmlovT sT/MtRxr /NOn raRp CONSM CONSULTANTS 1D REMOVE EXISTING CEILING TILE, GRID AS INDICATED TO EXTEND CEILING GRID. O2 REMOVE EXISTING LIGHT FIXTURES, AND POWER LINES AS INDICATED TO REV DATE JC DESCRIPTION SUPPORT NEW ELECTRICAL REQUIRE- MENTS. SEE REFLECTED CEILING PLAN FOR FURTHER INFORMATION. at c ��Fq e r e-6 I Mpy 1 � 200 ` 0 k�i1a �, M DEMOLITION PLAN NOTES 20 REMOVE EXISTING WALLS AS INDICATED. O REMOVE EXISTING FLOOR FINISHES AS INDICATED AND REPAIR /REPLACE SUB - FLOOR AS REQUIRED TO PROVIDE AN EVEN WALKING SURFACE FOR A FINISH FLOOR CONDITION. 22 REMOVE EXISTING PLUMBING FIXTURES AS INDICATED. CAP LINES AS NECESSARY FOR THOSE NOT BEING RE -USED. SEE CONSTRUCTION 8 FLOOR FINISH PLAN FOR FURTHER INFORMATION. 23 REMOVE EXISTING VINYL WALL COVERING, INCLUDING MURAL GRAPHICS. PATCH AND REPAIR AS REQUIRED TO PROVIDE A SMOOTH, PANT READY CONDITION. U.N.O. 24 REMOVE EXISTING U/C REFRIGERATOR. G.C. TO COORDINATE WITH STARBUCKS RCM FOR DISPOSAL OR STORAGE OF U/C REFRIGERATOR. 25 REMOVE AND DISPOSE OF EXISTING BANQUETTE. INCLUDING CUSHIONS. FRAME & MOUNTING HARDWARE PATCH AND REPAIR FLOOR AS REQUIRED. 28 REMOVE 6 DISPOSE OF EXISTING BACKLINE CASEWORK AS INDICATED. PATCH AND REPAIR WALL AS REQUIRED TO PROVIDE A SMOOTH PAINT READY FINISH. SALVAGE EQUIPMENT AS NOTED. 27 REMOVE AND DISPOSE OF EXISTING CONDIMENT CART TOP. SALVAGE METAL RACK FOR RE- INSTALLATION. 28 REMOVE AND DISPOSE ALL STARBUCKS PROPRIETARY ART U.N.O. 29 REMOVE EXISTING LOCKERS. SALVAGE FOR RELOCATION. \I 0 1 2 3 4 8 12 I II � L � .I II �',ff Inch 1/16 ZI ��I '�` "RS 3.z 17 � i II 5L Yb Eb Z6 �brf �Ob L LI�IIII( IIII�III. II. LLI 1�. 11L )� III( �LLLL�I !l I,- I jl I goet"'t t44., , I. 51 I I 16 Y� '�' n - �,„ ... i �,.(� r �I_ll.l:�l�ll�l ll�.�, �U�l�ill ��1111lhII�IIII�IIII�ILLI�IIII� STORE NUMBER 3267 PHONE NUMBER: 208 57&1774 PROJECT NO 03267 -044 SQ. FT: F- a 11 JAN 2005 Z U JC: DAVID LIU CHECKED: w 0 W a ED 00 Q W00 Q = Q 0 m� Z �g W C7 �— v --- Y a a � PROJECT NO 03267 -044 SQ. FT: 2036 ISSUE DATE: 11 JAN 2005 PM: WARREN PHILLPS JC: DAVID LIU CHECKED: MARK MEADOWS SCALE: 1/4 " =1' -0' (DO NOT SCALE DRAWINGS) SHEET TITLE DEMOLITION PLANS A3.0 PF nEFLCU I CU UtILIINU rLAN Inch 1/16 • r' a 1' ► R ,t� � e ! � , I ',i r tit ,�% �+I �6 b6 E6 Z6 66,, O6 b �00 GENERAL NOTES G NUMERICAL. NOTES NOT LISTED ARE NOT USED. O CASEWORK INSTALLATION IS PART OF GC SCOPE OF WORK. © FOR WALL HUNG /MOUNTED GRAPHICS, SEE A6 ELEVATION SHEETS. DO CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY RCM ANY DISCREPANCIES PRIOR TO CONSTRUCTION. ALL DIMENSIONS TO BE TAKEN FROM DESIGNATED DATUM POINT. O DIMENSIONS ARE TO FACE OF FINISHED SURFACE LION. OF GENERAL CONTRACTOR AND CASEWORK VENDOR TO VERIFY ALL DIMENSIONS AND CONDITIONS. NOTIFY RCM OF ANY DISCREPANCIES PRIOR TO CON- STRUCTION. OH FOR NEW AND RELOCATED ELECTRICAL COMPONENTS, THE ELECTRICAL. CONTRACTOR SHALL FURNISH AND INSTALL ALL LABOR, MATERIAL., AND EOUIPMENT NECESSARY TO COMPLETE THE ELECTRICAL WORK. O FOR NEW AND RELOCATED PLUMBING FIXTURES, THE PLUMBING CONTRACTOR SHALL FURNISH AND EQUIPMENT NECESSSARY COMPETE THE PLUMBING WORK. O REFER TO SHEET SC1 FOR COMPLETE COMPONENT SCHEDULE. REFLECTED CEILING PLAN NOTES 10 INSTALL NEW TASK LIGHT TO UNDERSIDED OF UPPER CABINETS. 11 MODIFY EXISTING CEILING GRID AND TILES AS REOUIRED. FLOOR FINI NOTES O NEW WICK -OFF MAT TO REPLACE EXISTING WALK -OF MAT AREA O ALIGN TILE GROUT LINES. O3 LEAVE META. TRANSITION STRIP. O EXISTING FLOOR SINK TO REMAIN. O FURR WALL OUT AS REQUIRED TO PROVIDE A FLUSH SURFACE. © SEE SCI FOR FLOOR SCHEDULE. WALL TYPE LEGEND: WALL TYPE CONSTRUCTION/DETAL LOCATION O NEW PARTITION WALL TO 6" ABOVE CEIING z � GA 3 %" MTI. STUDS 16" OC WITH TYPE "X' _ I DAVID LIU GWB ONE OR 80TH SIDES TO M IN OF 6" ABOVE CEILING GRID. DRYWALL SCREWS o 12" OC. 45 DEGREE MTL STUD o REINFORCEMENT 0 6' -0" OC ABOVE Q CEILING LINE TO BUILDING LID. SYMB WALL TYPE EXISTING WALL: NEW WALL: mo 0 1 2 3 4 8 12 J 6 Z w� FOR Com CnmpLjp MAY � �' 2005 U 2007 STARWJ= COIiptATXN STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH, SUITE 800 SEATTLE, WASHINGTON 98134 (206) 3181575 !WSE PLNG AV SKCFICATIONS. AS VM AS "9LUWn FROMMY OF NATION. My R[PROCUCTION, -CUM MOOR USE OF R ANY PORTION OF TH M Kr PRIOR inert Co"Son CONSULTANTS REV DATE JC DESCRIPTION STORE NUMBER: 32 6 7 PHONE NUMBER: 206 575-1774 PROJECT NO. 03267 -044 SCI. FT 2036 Q 11 JAN 2005 z V JC: DAVID LIU CHECKED: w o W Q D Lu Co Q Lu 00 Q Q o � D 0 Z Lu CD � v vo U c . CL v PROJECT NO. 03267 -044 SCI. FT 2036 ISSUE DATE: 11 JAN 2005 PM: WARREN PHILLPS JC: DAVID LIU CHECKED: MARK MEADOWS SCALE: 1/4 " =1'-0" (DO NOT SCALE DRAWINGS) SHEET TITLE FLOOR PLAN / FLOOR FINISHES A3.1 CONSTRUCTION & FLOOR FINISH PLAN �,o TILE 6053 BASE F , ELEVATION END OF BAR &aEMMN 7 _ MW 110= rAGIMCTe �7 FRPi W C.B.S. 3 N N W NEW BREW STATION W oCCDIr el loom wn etiv n _ELEVATION (7a BACKBAR m� — - E) GENER NOTES nnnu 5 11 1 - DD �� ___ELEVATION STOREFRONT i X21 ��� Inch 1/16 y ( L � NNN• M� lY "•] � 1 IIIIIII�IIIIIII l�_ llI II�III�IIIIIIII. �LIIIIIIIL�LILI_ �LLLL�LILL�JIII��LI l���lIILI) s I AO REFER TO SHEET SC2 FOR FINISH INFORMATION - N NOT USED. C� ALL PANT DESIGNATIONS TO EXTEND MOUND OUTSIDE CORNERS, UNLESS OTHERWISE NOTED. © SEE SHEET All FOR CEILING FINISH CkLOUTS, EO CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY PROJECT ARCHITECT OF MY DISCREPANCIES PRIOR TO CONSTRUCTION. ALL DIMENSIONS TO BE TAKEN FROM DESIGNATED DATUM POINT. F� DIMENSIONS ARE TO FACE OF FINISHED SURFACE LION. ELEVATION SHEET NOTES O1 EXISTING LOCH. ART WORK TO REMAIN. O NEW CHAIR RAIL, MATCH EXISTING. ® LAMINATE DOOR FINISH PANELS TO MATCH EXISTING ADJACENT CASE WORK.REFER TO CASEWORK FINISH SCHEDULE FOR MORE INFORMATION. 49 0 9 �U` o � � 4 , ED FO�C'� c ompa MAy v U =W3 STS, COMORATION STARBUCKS COFFEE COMPANY 2401 UTAH AVEIAJE SOUTH, SUITE 800 SEATTLE, WASHINGTON 98131 (205)318-15 MSC KAHS No SPCCtICATmHS, AS WU AS STAASUCKSI NMI NO 1000, TRXXmAMfS NO OCSICNS_ Ne THE C%C twn P*wum OF MR Nn ►ONTfON Or THT]U CW PFXR •IOfi[rl CoNsw CONSULTANTS REV DATE JC DESCRIPTION STORE NUMBER 326 PHONE NUMBER 206 575.1774 z U 0 W D Q U 0 z w � ir CL U W O CL CL Q a a W oo Z� w oo �< C/) z �H Y U PROJECT NO. 03267 -044 SQ. FT- 2036 -- � - ru k�, j i►� ISSUE DATE: 11 JAN 2005 PM: WARREN PHILLPS Al JC: DAVID LIU CHECKED: MARK MEADOWS P2 0 1 2 4 9 SCALE: 3/8 " =1' -O" (DO NOT SCALE DRAWINGS) SHEET TITLE INTERIOR ELEVATIONS m E1701 el F Jr LAWIIMU HUNT BAR I, T ELEVATION INSIDE OF END BAR ELEVATION FRONTBAR . R EXISTING FRONT BAR TO REMAIN ELEVATION INSIDE FRONT-BAR `f � I 17 I I ` _ELEVATION (7a BACKBAR m� — - E) GENER NOTES nnnu 5 11 1 - DD �� ___ELEVATION STOREFRONT i X21 ��� Inch 1/16 y ( L � NNN• M� lY "•] � 1 IIIIIII�IIIIIII l�_ llI II�III�IIIIIIII. �LIIIIIIIL�LILI_ �LLLL�LILL�JIII��LI l���lIILI) s I AO REFER TO SHEET SC2 FOR FINISH INFORMATION - N NOT USED. C� ALL PANT DESIGNATIONS TO EXTEND MOUND OUTSIDE CORNERS, UNLESS OTHERWISE NOTED. © SEE SHEET All FOR CEILING FINISH CkLOUTS, EO CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY PROJECT ARCHITECT OF MY DISCREPANCIES PRIOR TO CONSTRUCTION. ALL DIMENSIONS TO BE TAKEN FROM DESIGNATED DATUM POINT. F� DIMENSIONS ARE TO FACE OF FINISHED SURFACE LION. ELEVATION SHEET NOTES O1 EXISTING LOCH. ART WORK TO REMAIN. O NEW CHAIR RAIL, MATCH EXISTING. ® LAMINATE DOOR FINISH PANELS TO MATCH EXISTING ADJACENT CASE WORK.REFER TO CASEWORK FINISH SCHEDULE FOR MORE INFORMATION. 49 0 9 �U` o � � 4 , ED FO�C'� c ompa MAy v U =W3 STS, COMORATION STARBUCKS COFFEE COMPANY 2401 UTAH AVEIAJE SOUTH, SUITE 800 SEATTLE, WASHINGTON 98131 (205)318-15 MSC KAHS No SPCCtICATmHS, AS WU AS STAASUCKSI NMI NO 1000, TRXXmAMfS NO OCSICNS_ Ne THE C%C twn P*wum OF MR Nn ►ONTfON Or THT]U CW PFXR •IOfi[rl CoNsw CONSULTANTS REV DATE JC DESCRIPTION STORE NUMBER 326 PHONE NUMBER 206 575.1774 z U 0 W D Q U 0 z w � ir CL U W O CL CL Q a a W oo Z� w oo �< C/) z �H Y U PROJECT NO. 03267 -044 SQ. FT- 2036 -- � - ru k�, j i►� ISSUE DATE: 11 JAN 2005 PM: WARREN PHILLPS Al JC: DAVID LIU CHECKED: MARK MEADOWS P2 0 1 2 4 9 SCALE: 3/8 " =1' -O" (DO NOT SCALE DRAWINGS) SHEET TITLE INTERIOR ELEVATIONS m E1701 el F Jr LAWIIMU HUNT BAR I, T ELEVATION INSIDE OF END BAR ELEVATION FRONTBAR . R EXISTING FRONT BAR TO REMAIN ELEVATION INSIDE FRONT-BAR PF EO EO \ / — — — . —. —•— — •— •— •— • —• —\— /— •— •— • —• —•— GOa9 1 O 2 /' \ - I ,/ ELEVATION ART WALL I IE n ELEVATION VESTIBULE P3 3' -8" 2OF2 io in P3 X ELEVATION (c� VESTIBULE n ELEVATION na VESTIBULE e R�VIEwE ®F � c® �'� m- COmpap' v r , .0 %orb .MAC �2Z005 0 1 2 4 8 I���I�t�l� �II �i�I�i�I�I�I . • it��� .t " �I�I�I�I� . . Inch 1/16. '� ' T ' -,: ; ,r�3 �•,.o<,,. 5L ti6 EL Z6 66�� X 06 6 8. � I I III�I II III IIl�1�.IIlllll�l l 11111 ll.�ll 1 1 1 1 ll��� LIILILI II �L . �III�IILIIILIllalllll_I)Itlll( s I- Z L w� V v 0 4 0 GENERAL NOTES OA REFER TO SHEET SC2 FOR FINISH INFORMATIC -------------------------------------------------------- - - - - -- - -- OB NOT USED. I 1 1 1 I I 1 I (208) 318.1575 © ALL PAINT DESIGNATIONS TO EXTEND AROUND I I I 1 I P3 = I STNleuolr►" WMTTEN CoNsufT IS STIIICiLY PRd�iEp, OUTSIDE CORNERS, UNLESS OTHERWISE NOTED. I I i I i I I 3267 OD SEE SHEET All FOR CEILING FINISH I i I 1� Q CALLOUTS. I 1 1 I 1 I I I 1 I c c OE CONTRACTOR TO VERIFY ALL DIMENSIONS I I J I I I 1 I I I i J AND NOTIFY PROJECT ARCHITECT OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. ALL DIMENSIONS TO BE TAKEN `__ I 1 I I Q z� w FROM DESIGNATED DATUM POINT. -_ ` - O 1 o Y z (1) FO DIMENSIONS ARE TO FACE OF FINISHED SURFACE UON. CL 0 PROJECT NO. 03267 -044 SQ. FT- 2036 ELEVATION SHEET NOTES PM: WARREN PHILLPS JC: DAVID LIU CHECKED: MARK MEADOWS O EXISTING ARTWORK TO REMAIN. (DO NOT SCALE DRAWINGS) P3 X ELEVATION (c� VESTIBULE n ELEVATION na VESTIBULE e R�VIEwE ®F � c® �'� m- COmpap' v r , .0 %orb .MAC �2Z005 0 1 2 4 8 I���I�t�l� �II �i�I�i�I�I�I . • it��� .t " �I�I�I�I� . . Inch 1/16. '� ' T ' -,: ; ,r�3 �•,.o<,,. 5L ti6 EL Z6 66�� X 06 6 8. � I I III�I II III IIl�1�.IIlllll�l l 11111 ll.�ll 1 1 1 1 ll��� LIILILI II �L . �III�IILIIILIllalllll_I)Itlll( s I- Z L w� V v 0 4 0 © 2W3 PAREUM com o urm STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH, SUITE 800 SEATTLE, WASHINGTON 98134 (208) 318.1575 TWX PLANS AND wwnrATOO. As WELL As STAM)CWNM[ AND LOCO, TRADC WIKS MO oE906 N"E TK DMUME PROPERTY OF STARBUCKS COWMArM. MIY R[PIIOOUCTIOK YOOPICATION.OI5QAA1[ pm, us o< TTCU wTEinrLS to wrr rorT"oN as TKM1 = I STNleuolr►" WMTTEN CoNsufT IS STIIICiLY PRd�iEp, CONSULTANTS REV DATE JC DESCRIPTION 3267 STORE NUMBER: PHONE NUMBER: 208 575.1774 1� Q V z c c O W CL H W o C) Q z� w Q =Q o Y z (1) w o� C� U W CL 0 PROJECT NO. 03267 -044 SQ. FT- 2036 ISSUE DATE: 11 JAN 2005 PM: WARREN PHILLPS JC: DAVID LIU CHECKED: MARK MEADOWS SCALE: 3/8' =1' -0" (DO NOT SCALE DRAWINGS) SHEET TITLE INTERIOR ELEVATIONS A6.1 i COMPONENT SCHEDULES; O O O O O MISCELLANEOUS SCHEDULE: 1 ITEM- OTY DESCRIPTION MMr MANUFACTURER I MODEL • I VOLTS I AMPS I SUPPLYI WASTE I REMARKS SKU SHIP M054 1 SOAP DISPENSER LAVATORY MNTD LOCKNET LLC ASI0332 Q FOR RESTROOM SINKS 181934 3PL M056 I FULL PAPER TOWEL DISPENSER FORT HOWARD '566 -50 "C" 3/4" I FOR RETAIL N. - ----- GC T102 O ACT 2' CROSS TEE - WHITE ARMSTRONG FOLD Z v - CW /HW AMERICA ONLY 119873 3PL M094 1 PLASTIC CORNER OUTWATER 'CC-17-132- 1/2" 3/4•' 1 WHITE TILES ONLY -- GC ;103 0 GUARDS (5) PLASTICS 4' r�_H 24 TILES) 178251 3PL CLEAR 183644 GC M099 1 METAL CORNER BFC ANGLE WH 2036 ISSUE DATE: 11 JAN 2005 WHITE TILES ONLY - - - -- GC JC: GUARDS ENTERPRISES 5 /8OX SCALE: 1/2" CW 1 PEWTER 1 .25 FINISH SS -- 1 159409' __ 189442 3PL CEILINGS SCHEDULE: ACT MFTAI S..ArT urTnl c T100 O ACT MAIN RUNNER - WHITE ARMSTRONG 7300WH MAIN Q TO BE USED WITH V z (BOX) PRODUCTS RUNNER 3/4" I WHITE TILES ONLY - ----- GC T102 O ACT 2' CROSS TEE - WHITE ARMSTRONG XL7328WH 2' Z v - CW /HW TO BE USED WITH 179252 API 6053 5 WALLCOVERING PRODUCTS CROSS TEE 1/2" 3/4•' 1 WHITE TILES ONLY -- GC ;103 0 ACT WALL ANGLE WHITE ARMSTRONG 7800WH WALL r�_H 24 TILES) 178251 3PL TO BE USED WITH 183644 VD P367 1 12X12 IMPORTS ANGLE WH 2036 ISSUE DATE: 11 JAN 2005 WHITE TILES ONLY - - - -- GC GRAPHICS SCHEDULE: [ITEM OTY DESCRIPTION MANUFACTURER MODEL REMARKS M11R01 C SKU SHIP G089 1 GA29 - PAPER ON I BLOCKS I DISPLAY STAMP ART Q V z (BOX) PRODUCTS SERIES 2 CROW 3/4" I 12 X 12 (BOX OF 15 TILES) 183737 VD C380 1 RM39 - DISPLAY K27 -Y001 Z v - CW /HW 24 TILES) 15CM X 30CM (BOX OF 179252 API 6053 5 WALLCOVERING PRODUCTS 16 X 8 1/2" 3/4•' 1 12 X 12 (BOX OF 15 181033 3PL 8004 1 LE EVANS ASSOCIATED Z7440 -WF r�_H 24 TILES) 178251 3PL TILES) 183644 VD FLOOR COVERINGS S CHEDULE: ITEM- OTY OESCRIPTION CERAMIC TILE TILE BASE O MANUFACTURER I MODEL - REMARKS SKU • I SHIP 8001 1 TILE LE LONGS ASSOCIATED TRADIZIONAL Q V z (BOX) IMPORTS 72802 3/4" I 12 X 12 (BOX OF 15 TILES) 189439 3PL 8002 1 LE CLOUD BEIGE ASSOCIATED K27 -Y001 Z v - CW /HW 24 TILES) 15CM X 30CM (BOX OF 179252 API 6053 5 OX) IMPORTS 72803 1/2" 3/4•' 1 12 X 12 (BOX OF 15 181033 3PL 8004 1 LE EVANS ASSOCIATED Z7440 -WF r�_H 24 TILES) 178251 3PL TILES) 189440 3PL P367 1 12X12 IMPORTS 72805 2036 ISSUE DATE: 11 JAN 2005 12 X 12 t80X OF 15 WARREN PHILLIPS JC: PITCHER RINSER ENTERPRISES ZURN Z -825F1 SCALE: 1/2" CW (DO NOT SCALE DRAWINGS) T ILES) 189442 3PL 8005 1 TILE - JACKSON ASSOCIATED STAINLESS INTEGRAL TO SS 182121 3PL 7 NERO 12X12 IMPORTS 72806 1/2" 12 X 12 f80X OF 15 . VD 8010 45 TILE ROAST3 GIZA CASEWORK VENDOR TO NE CWF TILES) 189443 3PL 30CM X 30CM (BOX OF 1 FAUCET FERGUSON STEEL 12X12 CERAMICHE CERAMICHE HE GIZA , GIZA COUNTERTOP C -250 VD B012 1 TILE INTERIM3 PASTORELLI TECNOSTONE, 15 TILES) 15 TI 179265 3PL DIAMANTE 12X12 CERAMICHE DIAMANTE CW /HW X 30CM (BOX OF 189613 VD 18 TILES) 179263 3PL B050 1 TILE BIANCO BASE PASTORELLI TRADIZIONAL Q V z 6 "X12' CERAMICHE E. BIANCO 3/4" I 15CM X 3OCM (BOX OF 188345 3PL P007 1 SINK WATER TOWER COMPONENT K27 -Y001 Z v - CW /HW 24 TILES) 15CM X 30CM (BOX OF 179252 API 6053 5 TILE NERO BASE PASTORELLI CERAMICHE TRADIZIONAL 1/2" 3/4•' 1 W/ GRILLE 181033 3PL POOR E. NERD COLD BEVERAGE SPOKANE Z7440 -WF r�_H 24 TILES) 178251 3PL 8040 3 WALK•OFF MAT PACIFIC MAT AZO BERBER 78•• X 48' 156384 3PL FLOOR NOTES; O 00 NOT ORDER. INFORMATION PROVIDED FOR REPLACEMENT OF TILE AS REQUIRED. O2 MATCH EXISTING GROUT. EQUIPMENT SCHEDULE: ITEM- OTY DESCRIPTION MANUFACTURER MODEL VOLTS AMPS SUPPLY WASTE REMARKS SKU SHIP �cr n,vc n.v, wrvi we E334 1 REDR GCOUNTER DELFIELO UC4048 115 4 SAME AS E301 RISC DISPENSER, FRAPP AC 220 FIP E564 1 MANUAL AC DISPENSING W/ TRAY 120 3 PLUMBING SCHEDULE: ITEM` OTYJ DESCRIPTION MANUFACTURER MODEL VOLTS AMPS SUPPLY WASTE REMARKS FIV TI IDCC 110101 1 3PL 187555 1 3PL SKU I SHIP P001 1 ICE BIN 90LBS W/ MOLT BIB -D -1418 Q V z DOME LID ENTERPRISES W/ DOME LID 3/4" I 16.5 X 12 X 17 188345 3PL P007 1 SINK WATER TOWER COMPONENT K27 -Y001 Z v - CW /HW COMPARTMENT SINKS 180463 3PL ZURN HARDWARE GROUP 1/2" 3/4•' 1 W/ GRILLE 181033 3PL POOR 1 COLD BEVERAGE SPOKANE Z7440 -WF r�_H CW /TW Y SINK 190076 3PL P367 1 STATION RH UNIT STAINLESS RH LAYOUT 2036 ISSUE DATE: 11 JAN 2005 WARREN PHILLIPS JC: PITCHER RINSER ENTERPRISES ZURN Z -825F1 SCALE: 1/2" CW (DO NOT SCALE DRAWINGS) CC INSTALL BACKFLOW 189564 3PL P051 1 HAND SINK CASEWORK VENDOR STAINLESS INTEGRAL TO SS 182121 3PL 7 DISPENSER HARDWARE GROUP STEEL 1/2" COUNTERTOP C -246 VD P052 1 WORK SINK CASEWORK VENDOR STAINLESS CWF INTEGRAL TO SS 181034 3PL P377 1 FAUCET FERGUSON STEEL 1/2" COUNTERTOP C -250 VD P057 1 CBS RINSE SINK SPOKANE STAINLESS BLENDER INTEGRAL TO SS PITCHER RINSE CW /HW COUNTERTOP POOB /P009 189613 VD P353 1 FAUCET BACKBAR FERGUSON PHONE NUMBER: 206 57 &1774 Q V z WORKSINK ENTERPRISES ZURN 1/2" AT BACKBAR P354 1 FAUCET HANDSINK FERGUSON ZURN Z v - CW /HW COMPARTMENT SINKS 180463 3PL ZURN ENTERPRISES 1/2" AT RESTROOM HAND w 0� 0 Z7440 -WF r�_H CW /TW Y SINK 190076 3PL P367 1 FAUCET BACKBAR FERGUSON SQ. FT 2036 ISSUE DATE: 11 JAN 2005 WARREN PHILLIPS JC: PITCHER RINSER ENTERPRISES ZURN Z -825F1 SCALE: 1/2" CW (DO NOT SCALE DRAWINGS) CC INSTALL BACKFLOW P373 TOWER 14" WATER COMPONENT PREVENTER IN SUPPLY 182121 3PL 7 DISPENSER HARDWARE GROUP KN26- 5000 -14 1/2" CWF 181034 3PL P377 1 FAUCET FERGUSON 1/2" LABORATORY HOT 8 M43LERPRISES INC ZURN Z-826F1 GC INSTALL BACKFLOW CW /HW PREVENTER IN SUPPLY 189613 3PL LIGHTING SCHEDULE: \1cj� 4W,�y�11■ A 6N- � �'t �, �Ii Iii °IIi �I� I.II i�I I II I III I h..I�I ICI iII j II I ] j I Iji III I j 5I I II1Ch ( 1 /16I 1I I Y"" • I :: 1 GI k , }I I � ' I I I I I V I .. I R 1 - L R 1 : � k r t' 1 t :Il �"(Pnmm.r�',�.� � n �. }. r, N"•-- i • R M . , � I f.l^nS ��i? S I�rl y ,( f � Si• -� �,1,, .• . I .:� ' MII 7 1 �� bl � 1 .'F�, I. WL.�FT j b I. � 4 fI ,r )� I �... g( �� til6 E6 Z w. I Z L WO iiliilllllll IILL�1 .1.1 IIIIII�IIIIIII III.I_III I� :._ I � ! I II �Iilll_LLLLLILi_ii.l. dill( Liiili��.. I_l �I�LLIIIIIIILLL� .��LI IILIIILLILIIIILIIIII�I� (IIIIIIIIII fill I SKU SHIP L4 Q�5 pFR Aftrc � NT U 2= STPASUM CORAORAT1011 STAR BUCKS S COFFEE COMPANY 2401 UTAH AVENUE SOUTH, SUITE 800 SEATTLE, WASHINGTON 98134 (206)318.1675 THESE KM4 AM VECFICATMMAS WILL As STARSUDW MAW AM LOCO. TRIOEIMUO MC OESIGO AE THE EXCLUSIVE PROPEM OF STAPSUOM CORPORATION. ANY RVIOMCTICIL MOOFICATXK VISMOSME XWOR USE OF THESE MATDIMLS (OR My PORTION OP TIM WTT WT STAMUDW PNM WRITTEN COWW O STRICTLY PRO"Em. CONSULTANTS REV DATE JC DESCRIPTION 3267 STORE NUMBER: PHONE NUMBER: 206 57 &1774 Q V z 1"— D W cO Q w/ Z v - Q T W co 2 Q O Z w 0� 0 r�_H Y t W PROJECT NO. 03267 -044 SQ. FT 2036 ISSUE DATE: 11 JAN 2005 PM: WARREN PHILLIPS JC: DAVID LIU CHECKED: MARK MEADOWS SCALE: NO SCALE (DO NOT SCALE DRAWINGS) SHEET TITLE COMPONENT & FINISH SCHEDULES SC.1 L EM- I OTY DESCRIPTION MANUFACTURER MODEL VOLTS WATTS AMPS REMARKS pir EXIST FINISH SCHEDULES: WA14S/11AIN3COT/PAINTED FN. CEILINGS N0. DESCRIPTION MATERVU MANUFACTtRER TYPE/COLOR REMARKS P1 RETAIL CEILINGS & MURAL NICHE WALLS PAINT PRATT &LAMBERT SCC11 - STARBUCKS ACCOLADE FLAT ENAMEL LRV -6 DOOR & DRAWER FRONTS, FINISHED END PANEL, FIT KIT, UPPER CABINETS, MELAMINE PURPLE 02 02 RETAIL WAINSCOT PAINT I PRATT & LAMBERT SCC16- STARBUCKS ACCOLADE NT. SATIN LRV -9 VALANCE & FACIA, REFRIGERATOR BROWN •3 P3 RETAIL UPPER WALLS PAINT PRATT & LAMBERT SCC6 - STARBUCKS ACCOLADE INT. SATIN LRV -26.5 WM PC119 BACKBAR WALL OWN •2 PIONITE- OLIVE ORGAN) P5 PUBLIC RESTROOM UPPER WALL PAINT PRATT & LAMBERT BEIGE STAIiBUCKS BEIGE 2 ACCOLADE INT. SEMIGLOSS LRV -45 P6 PUBLIC RESTROOM CEILING PANT ATT &LAMBERT SCC2-STARBUCKS ACCOLADE INTERIOR WDID OFF - WHITE 0 1 SEMIGLOSS LRV -68.5 P7 WORKROOM UPPER WALLS & CEILING & PAINT PRATT &LAMBERT SCCIO-STARBUCKS OFF-WHITE •2 A CCOLADE INT. SEMIGLOSS LRV -73.1 WM WD112 EMPLOYEE RESTROO EB BARISTA MERCH APRON ROLLING MERCH CUBE WMV ON MDF NEW RAISIN STAIN Dl*4 UPPER WALLS EB BARISTA DIE WALL PANELS, HANDOF PLANE WM V ON MDF LIGHT CHERRY STAIN P8 RETAIL ACCENT PAINT PRATT & LAMBERT TARBUCK ACCOLADE INT. SATIN LRV -14.4 CABINET END PANELS GREEN .j PIC RETAIL ACCENT PAINT PRATT & LAMBERT SCC17- STARBUCKS ACCOLADE INT. SATIN LRV -8 FI CAB, CORNER FILLER, STORAGE RED •2 P11 RETAIL ACCENT PAINT PRATT & LAMBERT SCC30- STARBUCKS ACCOLADE INT. SATIN LRV -10 BEAN INSERT SCRIBE; MERCH UNITS; BROWN •7 ADJACENT SURFACE AND EST RES WAINSCOT AND MELAM NEVARMAR SIENNA ESSENCE SUPPLIED BY CASEWORK EB100 NET EDGE BAND CORE CASEWORK INTERIOR; •ES-2 -3T MFG 1 /� WAINSCO MELAM MATERIAL IS EXTERIOR BOTTOM OF CABINET END PANELS TAPE C4 WAINSCOT PS TRIM TRIM TRIM PREC ISION B MATTE SUPPLIE FACIA; UPPER FIT KIT; UPPER FINISHED TAPE DO NOT P B A A JT CASE WO RK I ALW MFG. END PANEL; CORNER FILLER CAB. CONTACT CEMENT FRIPI W ORKROOM & OYES RESTROOM F RP MARLITE P -100 WHITE FULL HT. ALL AREAS, INCLUDING MOP SINK. W AINSCOT TAPE WD115 RETAIL WAINSCOT aASO- DICK ROOS (800) 888-2776 G -100 LINEN PROVIDED BY GC GENERAL NOTEST L PANT SUBSTRUTIONS ARE NOT ALLOWED. 2 To locate Pratt & Lambert Starbucks program dealer, call (800) 289 -7728 0800) BUY PRATT) Order paint by Starbucks Coffee Company Program SCC• 3.Submit Two (2) Sets of 8%" x11" brush -outs of ollpoint colors and finishes to the Storbucks CM for approval prior topointing. 4.Refer to interior elevations for color locations. 5. Al wood and metal surf aces shall be painted semi - gloss, unless otherwise noted. 6. Wall receiving vinyl mural wallcovering shall be smoothwall and PVC primed. Murals to be sealed. Sealer is provided with Mural. RENOVATION FINISH S CHEDULES: CASFWURK: RAA¢T A MAT. FN. LOCATION DESCRPTtON MATERIAL TYPE/F� WD102 PC107 BACKBAR DOOR & DRAWER FRONTS, FINISHED END PANEL, FIT KIT, UPPER CABINETS, MELAMINE CORIANDER FIBER 1S / CORIAN 'SILT' BY GC VALANCE & FACIA, REFRIGERATOR ALMOND 1S OAT981 -S CORE DOOR SOFFIT, CUP SHELF GENERAL NOTES: WM PC119 BACKBAR WALL PLAZA PIONITE- OLIVE ORGAN) AV674 -S W W ,103 F012 EB BARISTA TOPCAP, FIN WMV ON MDF/ NATURAL STAIN WDID SOLID MAPLE/ MELA- OUINELLA WM WD112 F095 EB BARISTA MERCH APRON ROLLING MERCH CUBE WMV ON MDF NEW RAISIN STAIN Dl*4 F096 EB BARISTA DIE WALL PANELS, HANDOF PLANE WM V ON MDF LIGHT CHERRY STAIN WDK)2 KIDD CASEWORK CORE CASEWORK INTERIOR; MELAMINE ALMOND 2S CABINET END PANELS SS COUNTERS BARISTA, BREWER, SINKS, TRASH, STAINLESS BRUSHED FI CAB, CORNER FILLER, STORAGE STEEL EBy02 EDGE BAND BARISTA; POS SIDE PANELS: PREPACK WOOD STAINS MATCH BEAN INSERT SCRIBE; MERCH UNITS; TAPE ADJACENT SURFACE ETAGERE EB100 PC= EDGE BAND CORE CASEWORK INTERIOR; PVC ALMOND BOTTOM OF CABINET END PANELS TAPE EB100 PCK)7 EDGE BAND DOORS, DRAWER FRONTS; VALANCE; PVC CORIANDER FIBER FACIA; UPPER FIT KIT; UPPER FINISHED TAPE END PANEL; CORNER FILLER CAB. EB100 PC122 EDGE BAND CABINET FACES; BACKBAR FINISH PANEL: PVC BLACK TAPE WD115 PC119 BACKBAR WAINSCOT �/ MDF PIONITE- OLIVE ORGANI MELAMINE AV674 -S 140-5 BACKBAR WAINSCOT TRIM VINYL TRIM ANTIQUE SAGE GENERAL NOTES: 1. Refer to casewqrk schedule and casework plan for locations yy wmv -white maple veneer 3. All wmv to have edge banding stained to match VENDOR PROVIDED CASEWORK MAT. FN. LOCATION DESCRPTION MATERIAL TYPE/COLOR TR500 WAINSCOT VINYL TRIM RETAIL CONDIMENT TOP SOLID SURFACE CORIAN 'SILT' GC- PROVIDED MATERIAL NO. DESCRIPTION MATERIAL MFG. /SUPPLIER TYPE /COLOR REMARI(S TR500 WAINSCOT VINYL TRIM TRI M 1- 800 44 8140110 NO PAINT COD S M ISCELLANEOUS N0. DESCRIPTION MATERWL MANUFACTURER TYPE /COLOR REMARKS MS INTERIOR DOOR WHITE MAPLE PROVIDED CLEAR FINISH SUPPLIED BY GC VENEER SOLID BY GC CORE DOOR GENERAL NOTES: 1. REFER TO PLANS & ELEVATIONS FOR LOCATIONS UPDATED MAR 27 98 II�I1I�L�III�1� IIIIIIIiillllll 1 J , I 1 Illj1 11111 1 I ._ 1 - j11 6 � I � I I Inch 1/16" 1 �2I #YXI f.��3I��T ( 1i� r- I s I P • 1 k I +R@T��HIw�qavl t J f i ^e mwr . li , _�{ _"'+�A!'}rf)�,♦ fk t ' ,� �`'� I �1 ��,, 11I •�. 0 � �t � NS`N�W ��.c � ?�Y �'1�. :,Y`}G. N7 f ' 4 Z � IN .7 I I I I I I I I I I I I I I I I LI I I I I I I I I I I I I I I LLI LI I I I I I I LI I LLI LL I LI LI LLI_I_I I �I hill LLI 1 1111 1 1 111 LI 111 11 111 I L LI I I IJ 1 I I I I LI I I (I 11 I I I I 1 11 , II I I I I I 111 I I I I I I I I I I I ., IIIIIIIIII o�F �- r?j -% G� O pZ�' e 00 0 © 2000 STAReaCxS CORPORATION STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH, SUITE 900 SEATTLE, WASHINGTON 99134 (208) 319.1575 TNest MJ#13 APO SPEOTICATOG. AS w[u As STARBLOW NAW AND LOCO, TRAOaM04 AND DICSIGNS APE TIE DxC tEW PR". V Of STANR=S CORPaRATx1N. ANr R0MR00WTXK WDF=T10K D3M0SUE AND/OR UX of TKSL YATEN&S (OR ANY PORTIDN OF TNUO Wm} STAFOUCKTIMM wwrTEN coNSpIT R sn'"MY PROHIMM. CONSULTANTS REV DATE JC DESCRIPTION STORE NUMBER: 3267* PHONE NUMBER 206 575.1774 � Q z V O W Q ^ W I..L H� Z Q >' U° > Q �< Z (0 J w 0� 0 U a v PROJECT NO. 03267 -044 SQ. FT: 2036 ISSUE DATE: 11 JAN 2005 PM: WARREN PHILLPS JC: DAVID LIU CHECKED: MARK MEADOWS SCALE: NO SCALE (DO NOT SCALE DRAWINGS) SHEET TITLE FINISH SCHEDULES SC.2 ___%1