Loading...
HomeMy WebLinkAboutPermit D05-115 - WATANABE RESIDENCE - NEW SINGLE FAMILY RESIDENCE• WANTANABE RESIDENCE 12256 46 AV S D05 -115 n City ax Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: ci.tulnvila.wa.us DEVELOPMENT PERMIT Stever: M. Mullet, Mayor Steve Lancaster, Directo►- Parcel No.: 0179000976 Permit Number: DOS -115 Address: 12256 46 AV S TUKW Issue Date: 11/03/2005 Suite No: Permit Expires On: 05/02/2006 Tenant: Name: WATANABE RESIDENCE Address: 12256 46 AV S, TUKWILA WA Owner: N Name: WATANABE 3AMES Phone: Address: 5916 18 AV S, SEATTLE WA Contact Person: Name: MARK TRAVERS Phone: 206 - 763 -8496 Address: 2315 E PIKE ST, SEATTLE WA Contractor: Name SKYWAY HOME IMPROVEMENT INC Phone: 206 772 -1886 Address: P.O. BOX 4084, RENTON, WA Contractor License No: SKYWAHI002O3 Expiration Date: 09/18/2007 DESCRIPTION OF WORK: CONSTRUCTION OF A NEW 2,448 SQ FT SINGLE FAMILY RESIDENCE, 423 SQ FT ATTACHED GARAGE AND 102 SQ FT COVERED DECK AREA. PUBLIC WORKS ACTIVITIES INCLUDE: Allentown Water & Sewer Assessment Fees, 3/4" water meter, connection to water main in 46th Av S, Pavement mitigation fee of $3.30 /SF of pavement cut, connection to existing side sewer stub. Stub located on property to the north. Cut and fill, 10' wide access and paved connection to pavement in 46th Av S, roof downspouts separate from footing drains, erosion prevention and sediment control. Value of Construction: $224,658.33 Fees Collected: $22,413.74 Type of Fire Protection: NONE International Building Code Edition: 2003 Type of Construction: VB Occupancy per IBC: 22 Public Works Activities: Channelization / Striping: Y Curb Cut / Access / Sidewalk / CSS: Y Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: N Hauling: N Start Time: End Time: Land Altering: Y Volumes: Cut 10 c.y, Fill 10 c.y. Landscape Irrigation: N Moving Oversize Load: N Start Time: End Time: Sanitary Side Sewer: Y Sewer Main Extension: N Private: Public: doc: IBC - Permit D05 -115 Printed: 11 -03 -2005 t' :a.' .1.. :t ee• ,;v:: "t.'„.rN�;.ilx I,.�S'?%, f.�l,'rs. `,4. :xt�`7..,... a`ib�' .2 }f� ilt.t••f.� .if..•.. .,v�.l' EdA':tfir:+•V' i1a• .f? ��.G.:xJ dxt }$. x,�bi Z Z �w �U UO C/) Cl J = CO L W L L CO D = 0 �-w Z t-- z� W w U� :O CO D H W F- �. L O wZ co py z �J.� cP Storm Drainage: r Street Use: Water Main Extension: 1 Water Meter: i i E j i City o. Tukwila Steven M. Mullet, Mayor Departinew of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: cOukwila.wa.us Y Y Profit: N N Private: Y * *continued on next page ** Steve Lancaster, Director Non - Profit: N Public: doc: IBC-Permit D05 -115 Printed: 11 -03 -2005 j Z = Z �W J U' 00f to 0: CO J �- fn V„ W 0. LL Q:. N = W H Z 1-- 0 Z !— W U� O N` W W, O. UJ Z CO) O ~• Z 190E Permit Number: Issue Date: Permit Expires On: Permit Center Authorized Signature: Date: �; , I hereby certify that I have read and �inedhis permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. City oY Tukwila Departniew of Coniunuiiity Developriient 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: cOukwila.wa.us Steven M. Mullet, Mayor Steve Lancaster, Directo,- DOS -115 11/03/2005 05/02/2006 The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the perfopmance of work. I am authorized to sign and obtain this development permit. Signature: Date: ) I I�� 1 0 Print Name: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. i doc: IBC - Permit D05 -115 Printed: 11 -03 -2005 Z `~ W U O, �o M to LL, W O J LLQ �D = �. w Z O. Z �- 5. �o o t] t`- =v. u~- o _Z U= O ~' Z City of Tullcwlla Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 PERMIT CONDITIONS Z �z Parcel No.: 0179000976 Permit Number: D05 -115 W Address: 12256 46 "S TUKW Status: ISSUED Suite No: Applied Date: 04/11/2005 v Tenant: WATANABE RESIDENCE Issue Date: 11/03/2005 0 p CO W J = H 1: ** *PUBLIC WORKS DEPARTMENT CONDITIONS * ** CO u- w 2: Contractor shall notify Public Works Utility Inspector Mr. Greg Villanueva at (206)433 -0179 of commencement and � J completion of work at least 24 hours in advance. LL Q co D d 3: Perform all Public Works activities per approved plans and specifications. _ z� The Permittee shall maintain a set of approved plans, specifications, and associated permits on the job site. z O W Permittee shall apply for a revision for proposed work that is not according to approved plans and specifications, and ? o permit conditions. v ON The Permittee shall schedule inspections with the Public Works Inspector, 206.433.0179, at least 24 -hours in advance. o w w Work covered prior to inspection will be uncovered at the expense of the Permittee. LL z w UN All public infrastructure construction is to be done under the control and at the direction of the Public Works Inspector. 0 Z Permittee shall repair and pay all costs associated with repair of damage to City infrastructure. 4: Temporary erosion control measures shall be implemented as the first order of business to prevent sedimentation off -site or into existing drainage facilities. 5: The City of Tukwila has an undergrounding ordinance requiring the power, telecommunications, and cable service lines be underground from the point of connection on the pole to the house. 6: Any material spilled onto any street shall be cleaned up immediately. 7: A bond in the amount of 150 %x cost of work within the City right -of -way, made out to the City of Tukwila for possible property damages caused by activities. 8: A copy of the Certificate of Insurance Coverage (minimum of $2,000,000 naming the City of Tukwila as additionally insured). 9: The site shall have permanent erosion control measures in place as soon as possible after final grading has been completed and prior to the Final Inspection. 10: Driveways shall comply with City residential standards. Driveway width shall be a 10' minimum and 20' maximum. Slope shall be a maximum of 15 %. Turning radii shall be a minimum of 5'. 11: Downspouts, driveway, patio and drainage from other impervious areas shall be collected in an on -site storm drain doc: Conditions D05 -115 Printed: 11 -03 -2005 i� 7 ,r. ;, „r..,,,ir <p . ::L.c'.iv rr. «.�krai:Srr zt�rif.tse'rf. ? ALks Kr'ilt,nk7 ti.�l`sh !e a +t..'� a'�tiq�t�'Y •.i+'r„ fir' di�LY�;r<. V�';.hlh;��.Stk!?.£�v�1ti'�'o;, +�'}�)Wj�y� .y" t' �� �+" ��Y``,l�lt'.�'t�+_ir'A'�r+:i� � {y City of Tulcwila race Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 system. Drains shall be 4" minimum diameter, PVC schedule 40 or corrugated poly ethylene pipe with a minimum 1% slope for gravity discharge to location approved by the Public Works Department. Downspouts shall not connect to footing Z drains. Footing drain and downspouts may share a single discharge pipe downstream of the lowest footing drain. z 12: The Land Altering Permit Fee is based upon an estimated 10 cubic yards of cut and 10 cubic yards of fill. If the final �w quantity exceeds this amount, the developer shall be required to recalculate the final quantity and pay the difference 0 in permit fee prior to the Final Inspection. t o o 13: Storm drainage system adjacent to the West property line being within 46th Ave. South, shall be replaced with new storm LU drainage pipe and CB(s). Coordinate with Public Works Utilities Inspector for acceptable materials to be installed, S2 u- O depth of system, and for removal of existing culvert along roe frontage. Connect to newt installed or to be P Y 9 9p property 9 Y� w � installed storm drainage, at the NW property corner. 14: From October 1 through April 30, cover any slopes and stockpiles that are 3H: IV or steeper and have a vertical rise of U¢ N a 10 feet or more and will be unworked for greater than 12 hours. During this time period, cover or mulch other disturbed w areas, if they will be unworked more than 2 days. Covered material must be stockpiled on site at the beginning of this Z period. Inspect and maintain this stabilization weekly and immediately before, during and following storms. p Z 1-- UJI 15: From May 1 through September 30, inspect and maintain temporary erosion prevention and sediment at least monthly. All ? o disturbed areas of the site shall be permanently stabilized prior to final construction approval. v ON 16: ** *BUILDING DEPARTMENT CONDITIONS * ** o F= w 17: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the U Building Official. - Z w U- 18: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center O H ( 206/431- 3670). Z 19: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 20: Truss shop drawings shall be provided with the shipment of trusses delivered to the job site. Truss shop drawings shall bear the seal and signature of a Washington State Professional Engineer. Shop drawings shall be maintained on the site and available to the building inspector for inspection purposes. 21: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 22: Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 23: All wood to remain in placed concrete shall be treated wood. 24: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 25: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be obtained at City Hall in the office of the City Clerk. 26: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. doc: Conditions D05 -115 Printed: 11 -03 -2005 ..1. : :,j,`.�e'.jtm':ri ",'ro�N:1�`. .... r_,. wF : ai.:aFas. , v'ttn'Li+ii�L x ,.: ':rz: "'rw ra it ens' Yv.: fet' �u ''#a`Sdit _ dst:1r.,i�r,L:i:;arss.+ . dsiui.•. . '�.. City of Tul,wlla i9C8 Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 s 27: Except for direct -vent appliances that obtain all combustion air directly from the outdoors; fuel -fired appliances Q shall not be located in, or obtain combustion air from, any of the following rooms or spaces: Sleeping rooms, z bathrooms, toilet rooms, storage closets, surgical rooms. W D 28: Equipment and appliances having an ignition source and located in hazardous locations and public garages, PRIVATE _30 ARAGES, repair garages, automotive motor -fuel dispensing facilities and parking garages shall be elevated such that 0 o the source of ignition is not less than 18 inches above the floor surface on which the equipment or appliance rests. w w J _. 29: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall N p LU be at points within the upper one -third and lower one -third of the water heater's vertical dimension. A minimum distance of 4- inches shall be maintained above the controls with the strapping. _, LL¢ 30: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Department of co a Public Health - Seattle and King County (206/296- 4932). w zF 31: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department z O of Labor and Industries (206/248- 6630). w w 32: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, v any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits o presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila w W shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the v Building Official from requiring the correction of errors in the construction documents and other data. L w z co * *continued on next page ** F Z doc: Conditions 005 -115 Printed: 11 -03 -2005 , �,. _ � � t;, Y �ti:d��e "rk' 'r �>A;i,c�.,l�i �> � {A4..,...., c .id r �° 51.! �r!�Jt�F,'oi. �.Q.0 ,. ,u_ a ��, :•'s, .+r,.'(,1G;� U':yS to :rdt'af :� S'�+a ts,,aq r�+:'f��a;: . � Cit y of Tuk r�oa Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: _ Print Name: a Date: // �3 O� doc: Conditions 005 -115 Printed: 11 -03 -2005 z J- ' J— w ug D U C l) 0; LU J F.. CO LL w 0 U- ?. COd �w z F- . F- 0 Z F- w 2� U 0 CO: O F- w W 2 F- �O . Z' UCO 0 F- O Z *nu 2 4 X 19"05 CITY OF TUKWILA ComMunity Developmer "` "epartment Public Works Departmen, Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 Building Perr " Do5-/ j5 Mechanical...Perrnit.No. 1 Public: Works Permit No. Project No. For office use onl Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION ` King Co Assessor's Tax No.:_ 0 0 00 -- 01� ;; Site Address: 1 � S Suite Number: Floor: Tenant Name: tX f>t 7 ,4AIlf 66 ZE.9eD,501 New Tenant: ❑ .... Yes ❑ ..No Property Owners Name: :TPAAC; \N*T N kAA'Qa'- Mailing Address: 5 116 \1A 4 3 6105 City State Zip : CONTACT : PERSON. :. Name: -- M PTV- I V6T-" Day Telephone: (2-06) 1 - 13 6 Mailing Address: Wit ILz ` b ZZ- City Slate Zip E -Mail Address: Fax Number (z o(o 1 326 -37-38 GENERAL CONTRACTOR INFORMATION (Mechanl.cal Contractor information on back page) Company Name: I cV� Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: _ * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance" ARCHITECT OF-RECORD..- All plans must be wet stamped. by Architect.of Record Company Name: Mailing Address & city State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: ENGINEER OF. RECORD All plans:must be wet stamped by Engineer of Record ' Company Name:. Mailing Address: Contact Person: E -Mail Address: City Day Telephone: Fax Number: State Zip permits plusticc changes \permit application (7.21)x1) Page l Z ;= Z �W � D U UO w= H �LL W 9_j LL co �w Z ZO W W U o E- W W 3:U LO .Z W U= O~ Z 4WILDING`PERMIT INFORMS "SON - 206=431 -3670 Valuation of Project (contractor's bid price): $ 1 * ' LLU �2 Existing Building Valuation: $ Scope of Work (please provide detailed information): W44 COVATt.)MUO C t ti�S Will there be new rack storage? []..Yes iZ I l cr l No If "yes ", see Handout No. for requirements. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single- family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) 4ISCu *For an Accessory dwe ( provide the following: Lot Area (sq ft): '1 . .7"y k Floor area of principal dwelling: l' 00k Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: _ q Compact Handicap _ Will there be a change in use? ❑ ....Yes 'R.No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: E].. Sprinklers ❑..Automatic Fire Alarm ❑..None Other (specify) 5�0 Will there be storage or use of flammable, combustible or hazardous materials in the building? E].. Yes X.No If" yes ", attach list of materials and storage locations on a separate 8 -I /1 x I I paper indicating quantities and Material Safety Data Sheets. \permits phu\icc changeslpermit application (7.204) Page 2 Z �W QQ� W UO to 0 co W J = H CO W WO �-- J LLQ to = d. �W Z F– t— O Z 1'-- �5 U� O N � H WW H �O W Z N H �. O Z Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1" Floor 00 � g 3 2 Floor P Floor Floors thru Basement Accessory Structure* Attached Garage ��� $ T3 'Detached Garage Attached Carport Detached Carport Covered Deck Uncovered.Deck PLANNING DIVISION: Single- family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) 4ISCu *For an Accessory dwe ( provide the following: Lot Area (sq ft): '1 . .7"y k Floor area of principal dwelling: l' 00k Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: _ q Compact Handicap _ Will there be a change in use? ❑ ....Yes 'R.No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: E].. Sprinklers ❑..Automatic Fire Alarm ❑..None Other (specify) 5�0 Will there be storage or use of flammable, combustible or hazardous materials in the building? E].. Yes X.No If" yes ", attach list of materials and storage locations on a separate 8 -I /1 x I I paper indicating quantities and Material Safety Data Sheets. \permits phu\icc changeslpermit application (7.204) Page 2 Z �W QQ� W UO to 0 co W J = H CO W WO �-- J LLQ to = d. �W Z F– t— O Z 1'-- �5 U� O N � H WW H �O W Z N H �. O Z t PUIMC WORKSTERMY TINT ' RMATION - 206- 433 -0179. Scope of Work (please provide detailed information): 1" VA� VS SAM FC�r �''1 e Coyle dj ' 00 yTT- S'I' VA �A ' Call before you Dig: 1- 800 - 424 -5555 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Wat er District ...Tukwila El ... Water District # 125 ❑ Availability Provided ❑ .. Highline [- ...Water i Se er District `...Tukwila El ... ValVue ❑ .. Renton ❑ ...Seattle ❑ ...Sewer Use Certificate ❑... Sewer Availability Provided El.. Approved Septic Plans Provided I ❑ ...Septic System - For onsite septic system, provide 2 copies of a current septic design approval by King County Health Department. Sulinnitted with Application mark boxes which apply)- i ...Civil Plans (Maximum Paper Size - 22" x 34 ") i ❑...Technical Inforrnation Report (Storm Drainage) ❑ — ❑ .. Geotechnical Report ❑. Traffic Impact Analysis '. ... Bond ❑ .. Insurance ❑ .. Easement(s) ❑ .. Maintenance Agreement(s) Hold Harmless 11� Propdsed Activities (mark boxes that apply): ❑ ...Right -of -way Use - Nonprofit for less than 72 hours ❑ .. Right -of -way Use - Profit for less than 72 hours ❑ .. ight -of -way Use - No Disturbance ❑ .. Right -of -way Use - Potential Disturbance Construction/Excavation/Fill - Right -of -way ✓ Non Right -of -way ✓ i Total Cut 10 cubic yards ❑ Work in Flood Zone j .Total Fill to cubic yards Storm Drainage ` .Sanitary Side Sewer . Abandon Septic Tank ❑ .. Grease Interceptor ...Cap or Remove Utilities ❑ Curb Cut ❑ . Channelization ❑ . Traffic Control Frontage Improvements `( Pavement Cut � .. Trench Excavation ❑ .. Looped Fire Line �. Utility Undergrounding i ❑ ...Backflow Prevention - Fire Protection " Irrigation " Domestic Water " ..Permanent Water Meter Size...�J' WO# 20 m OS ❑ ...Temporary Water Meter Size.. WO# ❑ ... Water Only Meter Size............ WO# ❑ ...Deduct Water Meter Size " ❑ ...Sewer Main Extension ............ Public Private ❑ ... Water Main Extension .............Public Private FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ ... Water ❑ ... Sewer ❑ ... Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: City Slate Zip Water Meter RefundBillina: Name: Day Telephone: Mailing Address: City State Zip *units plu&Qce ehanScApermit application (7.2004) Page 3 .. �.:.,.::. ,. ..: . �.u.�r >�; , N,.. ra_.r1t ..,, ..i;., ��l1 tI:i4Yri�r ;�. �c�S::t3�:.ti:' �a.. +d,aY,, � x:iti�.k:Y',fky �:'.J'a�3 >t t k,. y'�iq .�•Y.�, )' dr,.;,an,�a:.S� .:... ... _:....lu iJ«��. ..i� .i.i w�h'•.ii+" "� "s�h'�ara',•,r� �ei,:at t". �= ri«si�: �i Z 2 Z D JU UO CO W = H N LL W �J LL ? GO CY = F- W _ Z F- W O =. U� O C0. o I.- W W . F_ �. �Z llJ U =: 0 F.. Z .. ECHANICAIr`PERMIT INFORMATION = 206- 431 -3670. Ni MECHANICAL CONTRACTOR INFORMATION Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number:_ Contractor Registration Number: Expiration Date: * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** Valuation of Project (contractor's bid price): $ — �l Scope of Work (please provide detailed information): IOW 's - G R.,, WC A� Use: Residential: New .... ❑ Replacement..... ❑ Commercial: New .... ❑ Replacement..... ❑ Fuel lype : Electric ..... ❑ Gas .... ❑ Other: 0 -3 HP /100,000 BTU Indicate type of mechanical work being installed and the quantity below: Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Com ressor: Q Furnace <100K BTU Air Handling Unit >I0,000 Fire Damper 0 -3 HP /100,000 BTU CFM Furnace> 100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected Thermostat 15 -30 HP /1,000,000 BTU to Single Duct Suspended/Wall/Floor Ventilation System Wopd�as Stove 41 30 -50 HP /1,750,000 BTU Mounted Heater Appliance Vent IT Hood and Duct Water Heater 50+ HP /1,750,000 BTU Repair or Addition to Incinerator - Domestic Emergency Heat/Refrig/Cooling Generator S stem Air Handling Unit Incinerator - Comm/Ind Other Mechanical <10,000 CFM Equipment PERMIT APPLICATION NOTE5 -- Applicable to all permits m M CA on Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJU9Y BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. ALIWORIZED AGENT: Signatu � Date: 4 - / l'05 - � c' Print Name: NI � � Day Telephone: � � °� S Mailing Address: 2315 �� V,-, 0 �131Z2 City State Zip Date Application Accepted:. Date Application Expires: Staff Initials: \pc mus plus\icc chsnga \permit application (7.2004) Page A Z Q� ~ W 00 Cl) o J � W LL W J U. N d = W Z F- f- O Z I- 2� U ON 0 1— WW HF- -O •• Z W U= H� Z Nvw�+w«,�a..,...�+M.. rc+* rrr rwr�aa .wo +:teswti.xwr��;svarioaurarmt. ,, aK' tS�S* W.+ sdi".¢ 5�i' �1RAlk' �iFJ�tiP ?�"4�"t�9'�'�Lfi�''�}�..+�� I' _ 08 � Q City of Tukwila 1.9 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 RECEIPT Parcel No.: 0179000976 Permit Number: DOS -115 Address: 12256 46 AV S TUKW Status: APPROVED Suite No: Applied Date: 04/11/2005 Applicant: WATANABE RESIDENCE Issue Date: Receipt No.: R05 -01600 Payment Amount: 20,630.08 Initials: 7EM Payment Date: 11/03/2005 03:53 PM User ID: 1165 Balance: $0.00 Payee: LINCOLN ALAN LOUIE TRANSACTION LIST: Type Method Description Amount ---- - - - - -- -- - - - - -- --------------------- - - - - -- ------ - - - - -- Payment Check 5202 20,630.08 ACCOUNT ITEM LIST: Description Account Code ------------------------ - - - BUILDING - RES - -- ---------------- 000/322.100 CASCADE WATER ALLIANCE, 401/386.550 PLAN CHECK - WATER METER 000/345.830 PW LAND ALT PERMIT FEE 000/342.400 PW PAVEMENT MITIGATION 000/344.101 PW PERMIT /INSPECTION FEE 000/342.400 PW PLAN REVIEW 000/345.830 SEWER - ALLENTOWN /RYAN 402/379.004 STATE BUILDING SURCHARGE 000/386.904 WATER - ALLENTOWN /RYAN 401/379.004 WATER CONNECTION 401/379.002 WATER INSPECTION FEE 401/342.400 WATER INSTALLATION (DEP) 401/386.520 WATER TURN -ON FEE 401/343.405 Current Pmts 2,099.48 2,222.00 10.00 23.50 330.00 168.75 -.25 9,825.30 4.50 5,356.80 60.00 15.00 490.00 25.00 Total: 20,630.08 z = z` W. JU U O N Cl W J � �LL WO J U_ Q C0 d. =W z_ z F. I- O Z F- W UU ON 01- W u1 N U' U_ O' .. Z 1 H 2 O z City of Tukwila 19A8 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 z H - JU UO. c o w= cn ~. U . W �. J LL Q co F-_ 1- O z F- w 5; U ON ❑ F- LU W H U U-- o ..z CO H 3:' O z RECEIPT Parcel No.: 0179000976 Address: Suite No: Applicant: WATANABE RESIDENCE Permit Number: Status: Applied Date: Issue Date: D05 -115 PENDING 04/11/2005 Receipt No.: R05 -00506 Initials: BLH User ID: ADMIN Payment Amount: Payment Date: Balance: 1,783.66 04/11/2005 12:39 PM $2,272.98 Payee: JAMES WATANABE CONSTRUCTION TRANSACTION LIST: • Type Method Description Amount ---- - - - - -- -- - - - - -- --------------------- - - - - -- ------ - - - - -- Payment Check 4800 1,783.66 ACCOUNT ITEM LIST: : Description Account Code Current Pmts ------------------------ - - - - -- ---------- - - - - -- ------ - - - - -- PLAN CHECK - RES 000/345.830 1,364.66 PW BASE APPLICATION FEE 000/322.100 250.00 PW PLAN REVIEW 000/345.830 169.00 ` Total: 1,7$3.66 0 1 6 0- INSPECTION RECORD �! Retain a copy with permit S� INSPECTION NO. PERMI O. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (06)431 -3670 a'6 proved per applicable codes t IJdIU dl UJVV JVUI.11Lt DIVU., JUICe IVV. t-du ue tU secnea� relnspecLlon. P oject: Type of Inspection: A cTd � S Lp /4 Date Called: Special Instructions: r Date Wanted: D P.M. Requester: Phone No: `''� d 1 Receipt No.: Date: 9 Z IH W q � W =. UO UD co J = F- CO L WO LLQ d = W H ?H HO W 1- W U� O N 0 1.- Z: U- O �Z U= O Z Corrections required prior to approval. r ..T INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project ����� Type of Inspection: Address-c // Date Called: Special Instructions: Date Wanted: a.m. Gt 11f p.n,. Requester: 1?4ne No: ` Approved per applicable codes. El Corrections required prior to approval. _ c M �.. Su COMMENTS: v - 7/2,6/0 Inspector: / Date: 7 /2( � 6 (, $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Receipt No.: Date: z �Z �W Q� UO (00 C0 11.1 LU N LL W O. 2 QQ 9 LL co o = H =. Z� H O W �5 U0 O t. 0 F- W U_ W C0 U =. o� z 2� .off 5 • S? ' Z (..� 4+4 .£ �� i.. � .. { , 1 � l�^- .t1R'NWMY .- u'�LYex'l ?,�; tW�' '%. • L^T nJ ! J .. - _ 'L. +n °� �; .. , ? : ' ::.jl a� INSPECTION RECORD RECORD Retain a copy with permit��� INSPECTION NO. PER T CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 ( 06)431 -3670 I Project: aho 6 2 c, Type of Inspection: F , Address: 12.Z 561 Y &Ili/ S Date Called: Special Instructions: Date Wanted: p.m. 1 Requester: �one A 6 - 3 3 t/ - 2 5 yS Approved per applicable codes. ;0 .. I Project: aho 6 2 c, Type of Inspection: F , Address: 12.Z 561 Y &Ili/ S Date Called: Special Instructions: Date Wanted: p.m. 1 Requester: �one A 6 - 3 3 t/ - 2 5 yS Corrections required prior to approval. COMMENTS: 12z mss►- . :: " 10 Inspe tor: Date: 58.00 REINSPECTIA FEE REQUIR D. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. receipt No.: Date: Z Z �W J 00, N C0 W W = I— LL W O LL = �W Z WO �5 UC) O� WW = U u. ~O Z W U= o� z Project: Type of Inspection: Q � .. �'^ '?'�"'.""j.'M.. ,..+.i•1 �',* Z 41f!^).l^i^�'i'..w, ^ ±rT'T ++- '•+!+t�:^••'^^'S! � .".` �I v6 Special Instructions: Date Wanted: .;' Reque���� INSPECTION RECORD r Phone No: ou� 33 1- ( "7 y Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION }...;. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: Type of Inspection: Q i Addr Date Called: v6 Special Instructions: Date Wanted: < < a.m. 0. P m. Reque���� Phone No: 33 1- ( "7 y Approved per applicable codes. Corrections required prior to �,;,• ., p PP � q p � approval. ,..i S hy t� . ,0 ;{k t�tt iy+ COMMENTS: 'D tkoQ 79 _ T'�i"vN G t) r A J Inspector: � t. Date: Receipt No.: Date: MIA E] $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. 9 Z i� W �0 UO N U) LLJ J = Co LL WO La S � W Z ZO W W 5 CO 0 H W w, L O ill z N O Z INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: Type of Inspection: Address: (v flU Date Called: d>r, Special Instructions: Date Wanted: ig a.m. p.m. Requester: / ZG>m Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: WP J V 3 Inspector:% �� / Date: � o ! $58.00 REINSPECTICIN FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspectior Receipt No.: Date: " �' .+,wl:.}!..:t !, w• a� .' ,: '.,;,. c:. �i`.��� � c F. Z �Z �W QQ U O 0 C0 H N LL W O �aa LL Q F . W z� l'-O WH 5 U� O� W W LL O 6i Z Cl) O Z VT - I ,... stir- .R.�n.•.�a�..w: -. — • . -117 ?...r^w- em+- ?.�- n.a*w• ne- .t..^ r•....r- +.rm... rr- ;.nx•. -- .•n- +•n-.w — a INSPECTION RECORD ?� I Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Fl Approved per applicable codes. El Corrections required prior to approval. Project: Type of Inspection: Addre� s; ( Date Called: G G b Special Instructions: Date Wanted: t a.m. • *! OEM .� !` p.m. r Request r: n �� Phone � Inspector: � Date: Receipt No.: Date: $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. - • � :.'. ' . . - ....r.¢ ?•4�s_""`tn"ri�.�vy m "it � irk - ; �.'.��. Z Z �~ W UO to 0. C0 W J = Cl) LL, W O. J U- Q co = FW Z F- 0 W ~ W U O CO 0 1_ W H u 0 Z W U CO) O Z • *! OEM .� I r Inspector: � Date: Receipt No.: Date: $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. - • � :.'. ' . . - ....r.¢ ?•4�s_""`tn"ri�.�vy m "it � irk - ; �.'.��. Z Z �~ W UO to 0. C0 W J = Cl) LL, W O. J U- Q co = FW Z F- 0 W ~ W U O CO 0 1_ W H u 0 Z W U CO) O Z PAWA INSPECTION RECORD 'Retain a copy with permit INSPEtTIM NO. PER MT NU,. CITY, OF TU " BUILDING DIVISION T - (206)43 1 - 6300 Southcenter'BlYd., *100, Tukwila, WA 98188 70 I Project Type..o Inspection: 4, Address: Date Called: Special Instructions: Date Wanted: a.m. Requeftq% Phone No: Approved per applicable codes. Correcti'ons'required prior to approval. A COMMENTS: 5 ff ............... .0 '42 V f Inspector: j Date./ $58.00 REINSPECTION IF RE QUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedute reinspection. Rec eipt No.: Date: 0 z W 0 0 C a Cj) W: LU —J Cf) LL 0 2� 9M U- < M F- W 0 W W 5, 0 LU: F- U- 0 z C.) cf) P M 0 1-- z r' E INSPECTION RECORD ''�" Retain a copy with permit ' INSPECTION NO. PE ITN . CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 W2)43 -367 I t: Proje c Type of Inspection: Addres : Date Called: Special Ins ruc ions: Date Wanted: a.m. Requester: Phone No: ' Approved per applicable codes.'TCorrections required prior to approval. 1 I ki COMMENTS: YD `rte ` X / etc . 1 4 4, A I $58.00 119KIIIECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Receipt No.: Date: �*�.`;„. r'F+r7' , `tI +','...a.....• �:ti ":..a+b.wd+awn ✓*yr...:ir: 2 Z �W Q � W U. 00 N 0 W_ C0 L WO U_ Q cl) = C! H W. Z = Ir— H O W ~ W U� O N .0 1— W U H W Z W U= ~O H Z INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: Type of Inspection: Approved per applicable codes. Corrections required prior to approval. r. h� 1. k Inspector: / Date: S,- i� $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Receipt No.: Date: s Z �Z W UO N❑ J = H N LL ' WO 9-J LL Q U❑ = �W Z H W ~ 2j U ON ❑ N WW l-- H LL Z L11 U= O Z Address: 6 �� r � Date Called: 06 Special Instructions: Date Wanted: a.m. G p.m. Requester: J. Phone No: 1. k Inspector: / Date: S,- i� $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Receipt No.: Date: s Z �Z W UO N❑ J = H N LL ' WO 9-J LL Q U❑ = �W Z H W ~ 2j U ON ❑ N WW l-- H LL Z L11 U= O Z INSPECTION RECORD Retain a copy with permit 7 INSPECTION NO. PER 1 O A CITY OF'TUKWILA BUILDING DIVISION 6300 Southcen* Blvd., #100, Tukwila, WA 98188 (206)431 - 6 0 Pr ject: _ T fl A (3 f �� Type of Inspe tion: �- U A v►� ► r�! L.. Address: 215 L y O d S Date Called: Special Instructions: Date Wanted: L — 13 — QC� r p.m. Requester: Phone No: - Approved per applicable codes. Corrections required prior to approval. r� F� y t 4. 3 n T,. I: 1. Z �Z Q W W JU UO (D U co LLJ J F- S2 LL WO LL Q to =W H ZF- F-- O W W UC3 O� .0 H W H �. O lLl Z U =, O Z INSPECTION RECORD Retain a copy with permit INSPECTION NO. PER N CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 20 )431 -3�7 0 Project: Type of Inspection: Address: y�> Date Called: Special Instructions: Date Wanted a, y - .m. Requester: Phone No: �j Inspect Dat� o i Pat 00 REINSPECTION EE REQUIRED. or to inspection, fee must be 6300 Sc uthcent r Blvd., Suite 1 . Call to sechedule reinspection. I Reofpt No.: Date: z � W J UO N 0 W = fr- �LL W O La cl): = I- _ �O W ~ W U� O N O C;- WW <L —O .. z W O z PAP2 iy INSPECTION RECORD INSPECTION NO. Retain a copy with permit Do E CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3670 P . . 10 r� . ' t) A Type of I ection: c Y41 . IdI 2 As- -S & Date Called: Special Instructions: Date Wanted: L Requester: Phone No: * $ZAppj9ved per applicable codes. Corrections required prior to approval. COMMENTS: f �sp cto Date'. t I 5 00 REINSPECTION FEE REQUIRED Prio(to inspection, fee must be at 6300 Southcenter Blvd., Suite 100.'CalL to sechedule reinspection. Recelp Date: ry Z Z U U 0 N 0 C0 W W Cf) LL W LL co) CY W Z f. 0� W UJ U) . OH LLI W F- LL —0 z IJ C0 L) — �: X: 0 H. Z 0.l. ..ems.:: 1i.Jk- wt�'r; ^.a4 .. �R1 Y'I.Yi. V�Y^wti. t 4•� ... :-� . .. -... �. .;.. _.. .._ n..».... .... • .. r L6 INSPECTION RECORD Retain a copy with permit INSPECTION NO. R ACITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila WA 98188 6 0 r Approved per applicable codes C Project: �� {I, C, ' Type of l�ns,p X\ A dr `-. (.,. %, 144e Date Called: Special Instructions: r Date t ed, _ V ` a. m. A 1 Requester: Phone No: Corrections required prior to approval. COMMENTS: W 144e Cam' y'' ` A 1 a, Q e c� d JA qv4- s tom- n V �' � (( A R J r inspe r: � Date: $58. 0 REINSPECTION FEE R QUIRED. Prior to inspection, fee must be paid)t 6300 Southcenter Blvd., Suite 100. Cali to sechedule reinspection. Re N O.: Date: r Z W. Z UO CO 0 C0 LLI J = �L w J LL � = W z O �5 U� O N OH W Lu H U. LL ti— W Z U= O z.. M j INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERM CITY OF TUKWILA BUILDING DIVISION 1 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3610 Projec : Type of Inspection: i�> -M I YJ6 Address: 1 q (O 1 Date Called: Special Instructions: Date Wanted: L — 0 0 � t� P.M. Requester: Phone No: F] Approved per applicable codes. Corrections required prior to approval. i s COMMENTS: fi Inspec r: Date: l ,-1 . ice. e 58.00 REINSPECTI N FEE RE D. QU ft Prior to inspection, fee must be aid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Receipt No.: I Date: Z ;= Z QQ W W� 0 to 0 W = �U. WO LL N = W I^ _ z �. U O U. 0 E- W F- 0 �. co lLl O Z INSPECTION RECORD Retain a copy with permit'�5= /ls INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: Gc�Gc 6 -:) E'_ Type of Inspection: . 5�s 5 Address: laa �G -%'l ,¢U'- 5 Date Called: f93 6710 C Special Instructions: 1 Date Wanted: a /06 (p.m l G CY /IUGJY� Requeste Phone No: ars - 9 LJ be � s3- ass -G�35 ❑ Approved per applicable codes. Corrections required prior to approval. 555 I/ S Inspector: Date: 'M / L Receipt No.: Date: L I 1 $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must De J paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection r Z = Z UO Cl) Cl) = J F- Cf) U. W O L L cf) = F w ' Z I-- w � �p U O H. w W F- UL Z 111 U =: O F- - z �s .1 INSPECTION RECORD Retain a copy with permit - �� S INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: A e- Type of Inspection: weck'-r 'I Address: .1;2R54 Y� Date Called: Special Instructions: Date Wanted: a.m. iU 1 5 a 3 / U9�U(� m Requester: Phone No: Z 3- y - 7a - 9y nsl e - uhe�1 3 - �55 X13 Approved per applicable codes. Corrections required prior to approval. COMMENTS: K AA I oL) ,�. Inspector: ! <k Date: ' 31 c -/ Receipt No.: Date: $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Z Z � W� UO U) o C0 W J = �LL W O J LL Q N� s �W F- 0, W �5 U� O N 0 H W LL _ ~ Z CO i= 2 O F. Z 'Z Z" T INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION f 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Projec } t�: Type of Inspection: Addr S ,_�� // Date Called: U Special Instructions: Date Wanted: l r a.m. p.m. Requester: Phone No: E Approved per applicable codes. Corrections required prior to approval. W" • J ! , ` Inspector: � � (Date: .� F� $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspectior Receipt No.: Date: Z �Z JU UO cf) a C0 W W = WO LL Q: to = a Z F- F- O W F- W U� O o F-. = U. F- _ 111 P _ O Z INSPECTION RECORD Retain a copy with permit INSPECTOR NO. CITY.OF TUKWILA BUILDING DIVISION 6300 So'uthcenter Blvd., #100, Tukwila, WA 98188 (206)431-36y P r j e ct: 14, Aj.b to Type f I t* O 7� 1 ti, , Address Date Called Special Instructions: Date Wants : a.m. Requester: Phone No: r. ,eceipt No.: TD7t_e Z W �U 00 to Uj X: J Cl) LL 0 U_ (j) :) CY LU z z Ir— LU LLj N 0—. LU u j 3: L ) ILL z CO. 0 z paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. r� INSPECTION RECORD n / Retain a copy with permit s INSPECTION NO. PERMI O t CITY OF TUKWILA BUILDING Di'�fiaRON 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36 1 Project* 7 A-1 /3 Type of nsp� / ( / Ad ss: f a A � Date Called: '-'� ` / --., _ d Special Instructions: Date Wanted_ // / a.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: � r /a 1 44 m Inspector Date: r-1 elf ,r i I $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection Receipt No.: Date: ,r z IZ 1— W W� UO (1) O C0 W W = �U- WO 2� � �. Cl) d = W F- _ ? I-- ZO W W U �. O -, 0 F- WW HL) z U- F- _: O z INSPECTION RECORD Retain a copy with permit 65 11 INSPECTI N NO. PER T O. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36 Project: n Type of Inspecti A8dre s L y J ` Date Called:_ ^/ '�.-06 Special Instructions: Date Wanted: -- Zp-rii Requester: Phone No: l Inspector: $58 .�FOMINSPECfION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Receipt No.: Date: ::1 t Z �~ W J0 00 CO Q co 11.1 J = U. W 0 LL to =0 �W Z H F- O W �5 U� 0- o !- W W. H F. 6 0 li l Z co O Z INSPECTION RECORD Retain a copy with permit 2 INSPECTION NO. PERMI 9 CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 ( 3670 Project: f a Type of Inspection: _ Address: I{ �t _' Date C Iled: Special Instructions: Date Wanted: �a� .. .�� Requester: Phone No: Receipt No.: Date: y Z }_- Z W UQ (0 U) 111 J � N W W O u- Cl) 2 �W Z t— H O W H 5 U� O Cl) DH WW H H It. O . W Z 0 C0 P _. O Z I paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. RIVE INSPECTION RECORD Retain a copy with permit INSPECTION NO. PER IT 0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (20.6)151 Project: Type of Inspection: Address: Date Called: Special Instructions: V IC-, p% 4e Date Wanted: p.m. Requester: CV J1 VA Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS. Date 8.00 REINSPECTION JEE R17QUIRED.Prior to inspection, fee must be E Y15 p at 6300 Southcenter Blvd., Suite 100. Cali to sechedule reinspection. Receipt No.: Z W 0 U 0 ND Cl) W W J S2 LL w o LL CO) 0 1 0 LU z X: I-- Ir- 0 z I-- W W 5- 0 co , �C) :0 .W UJ . X LL --z U N Z 1-- INSPECTION RECORD �S, -� Retain a copy with permit INSPECTION NO. R CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 R206)431-3670 R oj*ect* J-Inspecti Type o M04� Address: I — A 7 a S 4 U -).r Date lip 1':) Special Instructions: Date Wanted: 0z Requ ster, 7 A'�A V 0 /- I 1- po PP : I Mcx No —a3 g —7 s; q9 11 Approved per applicable codes. Corrections required prior to approval. :OMMENTS: a!7 A0 Inspector • 144', Aawl� I Date: rl ( ( ' IR - F-1 $58.00 REINSPECTION EE REQUIR Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Cali to sechedule reinspection. Receipt No.: — [Date: 1 71 Z Z� 0, 00, NO Cl) W W = J C0 IL W C), 5 LL C0 LU F- 0 z �- W W 5; C') W W LL Z Cf)' O X , F-. z INSPECTION RECORD' Retain a copy with permit 1 INSPECTION NO. PER I O CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: - ,r_ r I Type of Inspection: Address: E C Date Called: o 4q105 Sp cial Instructions: Date Wanted: / GA - m�, p.m. Requester: i, �W Phone No r. / ,, V c Receipt No.: Date: Z IZ W J U, UO Cl) W= J C0 LL W 95 LL Q. LLI ? F— Z 0: W LLJ D WW XU tL Z N H 0 Z $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be " paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. KApproved per applicable codes. Corrections required prior to approval. { COMMENTS: f i i i, ` I i Receipt No.: Date: Z IZ W J U, UO Cl) W= J C0 LL W 95 LL Q. LLI ? F— Z 0: W LLJ D WW XU tL Z N H 0 Z $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be " paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. I i i Print Mar ('age 0 King County i' Parcel M ap and D ata 0179400850 27 174401065 0119001155 0174000710 0174001050 0179000715 1295 0179000720 0179000840 0179004435 0179001048 179001180 0179001046 0179040725 0179004835 179004950 179001045 a_; 179401170 1270 0179040735 0179440834 0174001042 v' 4179000985 0174001040 0179001185 ? 017 1261 . 0179040745 179000820 0179001195 179040755 0179000814 0119000915 0.1 7900 06 76 & 179000845 = 179000976 0179401200 0179 1250 790007 4179000785 01 01 7904701 7900121 4 +* 017 005 017 225 S 24TH-ST [017:9003OM:%'0 790034 0179003239 W900302' 7 0 790030 0 {C} 2002, tGnff County, 3�1z�.r.H s __ gam_ Parcel Number 0179000976 Address Zipcode Taxpayer The information included on this map has been compiled by King County staff from a variety of sources and is subject to change without notice. King County makes no representations or warranties, express or implied, as to accuracy, completeness, timeliness, or rights to the use of such information. King County shall not be liable for any general, special, indirect, incidental, or consequential damages including, but not limited , to, lost revenues or lost profits resulting from the use or misuse of the information contained on this map. Any sale of this map or information on this map is prohibited except by written permission of King County" Pa I of I C17 Op TVKW APR 11200 PERMIT CENTE King Coun _ GIS- Center News I Services I Comments I Search By visiting this and other King County web pages, you expressly agree to be bound by terms and conditions of the site. The details. http://Nvww5.metroke.gov/p,irceIN /1'rint t E; Or <<s 4/11/2005 0 Z ;= Z �W D U O (n D. W= J F, WW WO 9 Q CO D CY I W z : _ Z F- H O Z f" W W U� O CO W HC LL O w z CO O z I 1 i i LEGAL DESCRIPTION: LOTS 5,6,7, AND 8, BLOCK 6, HILLMAN'S LAKE FRONT ADDITION TO _ THE CITY OF SEATTLE, (DIVISION NO. 1), ADDITION, ACCORDING TO j. THE PLAT THEREOF, RECORDED IN VOLUME 10 OF PLATS, PAGE 44, IN KING COUNTY, WASHINGTON; EXCEPT THAT PORTION I THEREOF CONDEMNED IN KING COUNTY SUPERIOR COURT CAUSE NUMBER 236360 FOR AURORA AVENUE; AND EXCEPT THAT PORTION OF SAID LOTS 5,6, AND 7 CONDEMNED IN KING COUNTY SUPERIOR COURT CAUSE NUMBER 66850 FOR AURORA AVE. 1 Y� Lo C. HILLWAq Z Z �W 2 J J U, UO cl) J = H N W W O L L N n = d f. W Z F- O w h- 2 5 U� o� W � F �z ui S O z Z Z: �W Q 2 J O' UO U 0. Cl) =. J �. CO LL W 0' LL a cd =w �O z�- 2 �* Do ^O �. =U H LL Z ll.l U CO, O Z 11 Uz- Mili NOTICE: IF THE DOCUMENT IN THI UAY RAM OF THE DOCUMENT THIS NOTICE IT IS DUE TO THE QT i ; i Parcel 017900 -0975 KNIGHT JR ELDON LEONAt.il RITUrw TO JAbtES WATANABE 12252 46TH AVENUE So TUM'"I WA 98179 r ° , Wersrsoe N (if applicable) Grantor(s)t• Additional on Papt Gtantee(s)t Additional on Paget C� App d 'I'l -O and C ° nj4nt ST ATUTORY WARRANTY DEED ELDON LEONARD KNIGHT, JR. JAMS WATANABE i i Abbreviated Legal Dascriptiont PTN L16, ALL L 17 -18, BLE 5, ALLENTOWN i , Additional on r apt ADDITION, V12 /P100 RECEIVED - CITY OF TUKWILA Assessor's Tax Parcel IDN 017900- 0975 -06 APR 112005 PERMIT CENTER THE GRANTOR ELDON LEONARD KNIGHT, JR., unmarried, as bin separate estete for and In consideration of TEN DOLLARS AND OTHER GOOD AND VALUABLE CONSIDERATION i In hand paid, conveys and warrants to JAMES WATANABE, a single man the following described real estate, situated In the County of KING Sate of Washington: THE SOUTH ONE HALF OF LOT 16 AND ALL OF LOTS 17 AND 18, BLOCK 5, ALLENTOWN ADDITION TO THE CITY OF SEATTLE, ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 12 OF PLATS, PAGE'100, IN KING COUNTY, WASHINGTON. SUBJECT TOt AN ORDINANCE ESTABLISHING WATER CONNECTION AND SEWER CONNECTION FEES, RECORDING NO. 9706120642 Dated: October 26, 2004 ELDON LEONARD KNIGHT, JR. • owl I'S Mai .v .. ...... ... .. '...��. ..,. :..i... v- .� ". l... •' .....�....i ��L.k'a': F+'�.i�+.:4�.�.u'1.• >.urr.• � _ • �F}Y�i t H.�a'�ii ° . xY 4 f•.+:y1F�.A* � +��r+l�P >�,�V� "�."A�'t.11�i s "}:,ti Z J_ Z W vo W= J � � U_ W O 9- U_ Q = a W. Z H. Z O. 5 U� O C0. WW �U O .. Z': W CO) O z Location No Bank No r No Restricted No Yr Built/Renov Px ,,;c l 017900 -0975 KNIGHT JR ELDON LEONA,.✓ Bedrooms 2 Grade 5 Fair Total Baths i Parcel Data Very Good Parcel 0 Present Use Single Family(Rcs Use/Zonc) Name KNTGHTJR�: 1)ONLEONARA Accessory Imps Y Site Address , '1225246TH AV { S 98178: Jurisdiction TUKWILA Area Code 024 -002 Property Type Code 'R ' Block 5 Lot 16- 17 -18• { Legal Description ALLENTOWN ADD S 1/2 OF 16 & ALL 17 -18 Land Data,, Land SgFt 8,500 Use Exemption Acres 0.20 Environmental No Water WATER DISTRICT Topography No Sewer /Septic PRIVATE Tr&Mc No Views Rainier No Sound No Olympics No Lk Wash No Cascades No Lk Samm ' No Territorial No Lk/Riv /Crk No ..., Seattle No Other No Location No Bank No Tide/Shore No Restricted No f Waterfront Footage 0 Access Rights No Prox.Inluence No Poor Quality No Pagc I of 3 Z QQ '~ W ' J U 0 0 0 W = J to LL; W 0. L¢ = W Z 0 U D , 0 N � H W W. Z{ W U N 0 F— O Z Building/Improvement Building Nbr I of I Living Units I Yr Built/Renov 1934 Bedrooms 2 Grade 5 Fair Total Baths i Condition Very Good Basement 0 AGLA 900 Finished Bsmt 0 Accessory Imps Y Covered Parking 0 Pagc I of 3 Z QQ '~ W ' J U 0 0 0 W = J to LL; W 0. L¢ = W Z 0 U D , 0 N � H W W. Z{ W U N 0 F— O Z O King County C_ , 4 1 . NOTICE: IF THE DOCUMENT IN THIS FRAME IS LESS CLEAR THAN THIS NOTICE IT IS DUE TO THE QUALITY OF THE DOCUMENT. Indemnification and Hold Harmless and Permit Temporary in Nature Reference Number(s) of Related Document(s): D05 -085 / D05 -115 Grantor: Skyway Home Improvement, P.O. Box 4034, Renton, WA 98057 Grantee: CITY OF TUKWILA, a municipal corporation of King County, Washington Work Location: Along 46` Ave. South, located adjacent to 12252 & 12256 — 46 Ave. South Abbreviated Work Description: Work within the City Right -of -Way, including driveway access, utilities, undergrounding of power, and storm drainage. NOW, THEREFORE, the parties agree as follows: The Permittee shall indemnify, defend and hold harmless the City, its officers, agents and employees, from and against any and all claims, losses or liability, including attorney's fees, arising from injury or death to persons or damage to property occasioned by any act, omission or failure of the Permittee, its officers, agents and employees, in using the City's right -of -way under this permit. This indemnification and hold harmless shall not apply to any damage resulting from the sole negligence of the City, its agents and employees. To the extent any of the damages referenced by this paragraph were caused by or resulted from the concurrent negligence of the City, its agents or employees, this obligation to indemnify, defend and hold harmless is valid and enforceable only to the extent.of the negligence of the Permittee, its officers, agents, and employees. Further, the right -of -way permit herein is wholly of a temporary nature and it vests no permanent right to use whatsoever to the Permittee. Pagel of 4 z H .� w 2 �U UO U W =. J F- N LL, WO 9 - LL � d =W F- _ ? F- f-- O z I— U O - 0 H W H I--1 M= O, W z co O z V DATED this .? day of , I( ;( - 1 200S GRANTOR: t` 1) J IA) 5 k ("��� T `vJeivxrl z1C a limited liability corporation By: Print Nam :) A)q Its: OWOEL STATE OF WASHINGTON ) ss. COUNTY OF KING ) On this -D�� day of , 200 before me a Notary Public in ( and for the State of Washington, pers ally appeared to me known to be the CTvRr1 of 4v7\.Q I a limited liability I corporation that executed the reg ing instrument, and acknowledged it to be the free and voluntary act of said corporation, for the uses and purposes mentioned in this instrument, and on oath stated that he /she was authorized to execute said instrument. IN WITNESS WHEREOF, the day and year first above written. ••o`� NOTARY �,. • 'G�a p U8 L I C o. 2 BER G, 0 F� have hereunto set my hand and official seal My commission expires: J.;-Ykp �0 "Pkc -1 CT- 4 .•,.d..kah.0 iel�Jlw.}' n ti544.;ti.}.uS:.pt �i. a. ka: a:.:.'^' i.'•..<. vi.+:: w: arrt�Sh: is`.' w. .':ar�:�l',t.3e.:d`.+�.dx`�:i.' kv:�,. ,..:.c.�;. Z = z �2 D UQ wi J H N O W� U - cf) :. = a �w z� � - 0. Z t- 7- 5. U 0 CT 0 E- wW F- LL o w Z U= O ~. Z NOTARY PUBLIC, in and for the State of Washington, residing at //tt <iflG LO EXHIBIT A DEPICTION OF WORK LOCATIONS) a MEIER PER YfA I LK EP CITY OF LINE TUKWILA SS MH 1 16-1 _ REQUIREMENTS • Page 4 of R A S IST -11 A;,j • NEW 4*0 *0 PVC, - §EWERs,,i •15 ( "•SOL'ASHBLOCK EXI iff CO' tS v TYP. N C, GROUND I - : I ca ON ECT I To ..PP CU RTC 1 G ' ec 0 -;rART WAE it-X Q�l CHA�ft Lu NEW SERVICE CONNECTIO1 NEW I"t W I I W T I ----------- -- NEW - y4' WATER NEW Z 3: W ui. 2 D 00 CO a co ui- Lu _j LL. 0 LL Q. co cy LLI Z 0 z �_ W LIJ 5� W 0 WW L) u. 0 Z co 0 Z -BACKFILL-IN- 6? -LIFTS- CLEAN- COMPACTED FILL MATERIAL. fn 13 MATCH ADJACENT GRADE. SEED W/ GRASS MIX. (D ( j < LOT• 16 OT IT) E ' IC •: kW',4"0 6 -SEWER L I I y -5 E)l 6 ,�% lll N -WATER--,- NEW 2- MAIN TO REMAIN; 0 Cu .. I ..CAP SERVICE - CULVIRT LINE 0 PROP. CONN TO E) -.CT IST UNE & CITY ( ;. CULVE RT UNION. - Y4 ' N EiW WATER LINE.�' EXIST' AT CONN 10 N Ln 'I —CONNECT PROP. UN Go ce NEW B CONNjCT l:-7 . ....... .-I 1 7 _ SF TO CULVERT TY ME I0 (, I I t_EI 4! Ai- a MEIER PER YfA I LK EP CITY OF LINE TUKWILA SS MH 1 16-1 _ REQUIREMENTS • Page 4 of R A S IST -11 A;,j • NEW 4*0 *0 PVC, - §EWERs,,i •15 ( "•SOL'ASHBLOCK EXI iff CO' tS v TYP. N C, GROUND I - : I ca ON ECT I To ..PP CU RTC 1 G ' ec 0 -;rART WAE it-X Q�l CHA�ft Lu NEW SERVICE CONNECTIO1 NEW I"t W I I W T I ----------- -- NEW - y4' WATER NEW Z 3: W ui. 2 D 00 CO a co ui- Lu _j LL. 0 LL Q. co cy LLI Z 0 z �_ W LIJ 5� W 0 WW L) u. 0 Z co 0 Z S • '""\ 1 1 DATED this (2^ day of A 2005. GRANTEE: CITY of TUKWILA By: CQS �- Print Name: James Morrow Its: Public Works Director STATE OF WASHINGTON )SS. COUNTY OF KING ) On this day, before me personally appeared JIM MORROW to me known to.be the PUBLIC WORKS DIRECTOR for the City of Tukwila, and executed this instrument on behalf of the City of Tukwila in his capacity as PUBLIC WORKS DIRECTOR and acknowledged that he is authorized to do so at his free and voluntary act and deed, for the uses and purposes therein mentioned. IN WITNESS WHEREOF, I have hereunto set my hand and official seal the day and year first above written. -'� P` lo Name Ake ce A • D estc _ �SS1oN I NOTARY PUBLIC in and for the State of v`� �OTAgy 9 .. p 1 �.� Washington, residing at Il e �l 1 b y ;� N :• AU : 2 O F WAS ,� My commission expires: Page 3 of 4 .! Ati J ..V �_ _ _ .a.4.+»w 4Y:: ..µ.,rw. ': 1:14f{.7uw��14�.fi 7.+.- ,ia�.t:..+:1M;5'rsWN7}: w,Naiu:. • :i:Lii rM.� Z Imo. ww �5 JU UO N 0; W =' J � �LL W O: LL cn a 1w z 1 - 0 Z 2= D o CO) o �. w u. o . ..z w U co) H X' Z Return to: City Clerk City of Tukwila 6200 Southcenter Boulevard Tukwila, WA 98188 Above this line reserved for Recorder's use CONVEYANCE OF PUBLIC IMPROVEMENTS Grantor /Borrower: Skyway Home Improvement, Inc., a Washington State corporation P.O. Box 4084 Renton, WA 98057 Grantee /Beneficiary: CITY OF TUKWILA, a Washington municipal corporation Document Reference Number(s): D05 -115 Section/Township /Range: SE1 /4, 10 -23 -04 Assessor's Tax Parcel Number(s): 017900 -0976 Property Address: 1225646 1h Ave. South, Tukwila Property Legal Description (abbreviated): A portion of the SE 1 /4, Sec., 10, T.23N., R.4E., W.M., (a.k.a.) Adjacent to Lot 18, Block 5, Allentown Addition to the City of Seattle, according to the Plat thereof, recorded in Vol. 12 of Plats, Page 100, records of King County, Washington. Within Public right -of -way. DEED OF CONVEYANCE OF PUBLIC IMPROVEMENTS Page of z �QQ W� JU UO N C0 J H' CO U. W U- a. i d: z� �O z� W5 U� O = 5. u. ~O w z CO P _ 0 f- . z . 90V sw CONVEYANCE OF PUBLIC IMPROVEMENTS The Grantor, Skyway Home Improvement, Inc., a Washington State corporation; conveys, warrants, and dedicates to the City of Tukwila, a Washington State municipal corporation, the following described public water utility system improvements: Thirty three (33) feet of /4 -inch type K copper pipe, one (1) each – 3 /a -inch water meter box with '/4" check valve and angle stop, one (1) water tap service, one (1) eight inch saddle, one (1)' /4" core. stop, and all appurtenances. ENGINEERING COSTS: N/A CONSTRUCTION COSTS: $2,500.00 TOTAL: $2,500.00 situated in King County, State of Washington. DATED this ��' day of T, ( , 2006. GRANTOR: (title) STATE OF WASHINGTON) )ss. County of King ) I certify that I know or have satisfactory evidence tha N q� is the person who appeared before me, and said p ser on acknowledged that he /she signed this instrument, on oath stated that he /she was authorized to execute the instrument and acknowledged it as the o w ne (_ of ,5f<t4Q)61L1 1 —c-T e_ - �-r 'e r)mr Zhe a corporation, to be the free and voluntary act of such party for the uses and purposes mentioned in this instrument. Dated 0'711 1 Lc'(,, A IA s / - 7 / Notary Public in_gnd residing at I �t My appointment expi the State of Washington Z Z +� w . u� D 00. 0 C0 CO w w 0 U_ CO D = �w Z Z w D0 U o F- w H r LL O. ui Z U N1 H X O Z ILA, 0! i;' . 1908 August 19, 2005 Mark Travers 2315 East Pike Street f' Seattle, WA 98122 City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director RE: CORRECTION LETTER #3 Development Permit Application Number D05 -115 Watanabe Residence —12256 — 46 Avenue S Dear Mr. Travers: This letter is to inform you of corrections that must be addressed before your development permit(s) can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Public Works Department. At this time, the Building and Fire Departments have no comments. Plannins Department: Brandon Miles, at 206 - 431 -3684, if you have questions regarding the attached memo. Public Works Department: Jill Mosqueda, at 206 - 431 -2449, if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) complete sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messen-eer service. If you have any questions, please contact me at (206) 433 -7165. Sincerely, r✓ Brenda Holt Permit Coordinator encl xc: File No. D05 -115 p;lplanningUendAD05 -115 — correction Itr Kdoc bb 6300 Southcenter Boulevard, Suite #100 -a Tukwila, Washington 98188 * Phone: 206 - 431 -3670 * Fax: 206 - 431 -3665 Z w UO 00 J = H S2 LL uj J u- co = W Z F- HO Z I— w LLI � o U O� D F— wW HF- u' O w Z U =, O Z Ya �5 PLANNING DIVISION COMMENTS DATE: August 2, 2005 CONTACT: Mark Travers RE: D05 -115 ADDRESS: 12256 46` Ave South The Planning Division of DCD has reviewed the above permit application that was submitted on July 28, 2005. The application cannot be approved. 4 1. Tukwila Municipal Code (TMC) 8.25 governs the vehicle storage and parking on single- family residential property. The provisions of the code strictly limit the amount of approved durable uniform surface per lot. TMC 8.25.020 (E) notes: "No more than 50 percent of the front yard or 800 square feet, whichever is smaller, may be approved durable uniform surface ". The site map provided shows a front yard of 1200 square feet. The driveway occupies an area of 630 square feet, which is greater than 50 percent of the front area. The driveway must be reduced in size. �, :.F.. � e.; • -R .k'.,i'rA+1::r {dY.Sua:dS. asiul�:, .. o.: :i;f.+..,:M'a:::4�.swa...tu: Lt.sf.�i'vA � .. �, Y' �c1:. w'•+ na[ �, iss .:rt�'.t+i{::o:tA:k:ttuw�ttf�:. 3.r -3y �.x:: " k:s:�' .�•:�R+� c.'V�W`a:+�.!i Z Z JU U O' CO) O N w' w =: U) u.: w O 9-1 LL �d =w �_ Z f_ t- O Z 1- W W UC O N 0 f- - ww �U H LL O Z U H � O Z CITY OF TUKWILA PUBLIC WORKS PROJECT REVIEW COMMENTS www.ci.tukwila.wa.us Development Guidelines and Design and Construction Standards Permit M D05 -115 Project Name: Watanabe SFR 12252 46" Av. S Review M 3 Date: 06.13.2005 Reviewer: L. Jill Mosqueda, P.E. The City Of Tukwila Public Works Department (PW) has the following comments regarding your application for the above permit. Please contact me at 206.431.2449, if you have any questions. 1. Update the storm drainage design per our meeting on August 4` 2005. > i j z �Z ;s w JU UO LU J '.. S2 LL W O L CO d . = w` z �. z O, w w U� CO) W W H U W N H O z I l 0 CITY OF TUKWILA PUBLIC WORKS PROJECT REVIEW COMMENTS www.ci.tukwila.wa.us Development Guidelines and Design and Construction Standards Permit M D05 -115 Project Name: Watanabe SFR 12252 46" Av. S Review M 3 Date: 06.13.2005 Reviewer: L. Jill Mosqueda, P.E. The City Of Tukwila Public Works Department (PW) has the following comments regarding your application for the above permit. Please contact me at 206.431.2449, if you have any questions. 1. Update the storm drainage design per our meeting on August 4` 2005. > i j z �Z ;s w JU UO LU J '.. S2 LL W O L CO d . = w` z �. z O, w w U� CO) W W H U W N H O z I l Mark Travers a Architect a c June 23rd, 2005. Re: 12256 46 Ave S PERMIT #D05 -195 - Correction Notice #2 Dear Miles: This letter is in response to your correction letter dated 06/13. We have updated our drawings and have noted the changes below. General 1. Garden window is updated. See Site Plan on sheet Al and Floor Plan on sheet A2. 2. Parking will be provided on Lot 17, on 12252 46 Av S, new construction. See Floor Plan on sheet Al. Please feel free to contact our office if you have any questions regarding this project. Sincerely, An rea Losekann Mark Travers Architect RECEIVED Cr rV OF TUKWILA J U L 2 8 2005 PERMIT CENTER 1 1 - J - 'ORRECTION LT R# 2061763.8496 P 206 1 328.3238 F Why Too Quo Building 2315 E. Pike Street 5 y Seattle, WA 98122 -ins Z mo �D; J U� 0 0 N o J H; N LL` W o; L L CJ) = d w. ZO: AU M: . D 0: U !0 N; D h-; W W' H U; u. ~O 111 z 0 ~' Z N Mark Travers June 23rd, 2005. Architect Re: 1225646 th Ave S PERMIT #D05 -115 - Correction Notice #2 \16 Dear osqueda: This letter is in response to your correction letter dated 06113. We have updated our drawings and have noted the changes below. General 2. a) We don't need a percolation test anymore, as per our new system, so see sheet A1.1; b) See note on sheet A1.1. 3. Water line is shown 1 ". See sheet A1.1. 4. Sewer line is updated. See sheet A1.1 5. See sheet A1.1 6. The items you requested, as per our conversation on June 23` are provided. Please feel free to contact our office if you have any questions regarding this project. Sincerely, Andrea Losekann Mark Travers Architect b V'S CORRE TION LT R# . -�-• - i 2061763.8496 P 2061328 3238 F IV i Why Too Que " Building 2315 E. Pike Street rx Seattle, WA 98122 .t Z . J U: U O; U w = cl) LL w O, LL j, = f� I` _; ? H; t— O` z� .0 � H W W- - ~p1 w Z U (T O Z. e i'lq� i r � June 13, 2005 r � city of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director Mr. Mark Travers 2315 East Pike Street Seattle, Washington 98122 RE: CORRECTION LETTER #2 Dear Mark: Development Permit Application Number D05 -115 Watanabe Residence —12256 46 Avenue South This letter is to inform you of corrections that must be addressed before your development permit(s) can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Public Works and Planning Departments. At this time, the Building and Fire Departments have no comments. Planniniz Department: Brandon Miles, at (206) 431 -3684, if you have questions regarding the attached memo. Public Works Department Jill Mosqueda, at (206) 431 -2449, if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) complete sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in versa: and will not be accepted through the mail or by a messenjeer service. If you have any questions, please contact me at (206) 433 -7165. Sincerely, Stefaniw pencer Permit Technician encl xc: File No. D05-115 sks TALinks \Docs \D05- 115\D05 -115 - Correction Letter #2.DOC 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 • Phone: 206- 431 -3670 • Fax: 206- 431 -3665 1+ 1 Z �W Q � Q 2. JU UO ND C0 ui J = F— cn u,,. w LL (0 d =w zX F— O Z F— U.15 ON W W LO .Z w U= H F- O Z or �rl 35 p ;b 1 1 1 1 1908 DATE: CONTACT: RE: ADDRESS: { City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director PLANNING DIVISION COMMENTS June 2, 2005 Mark Travers, Architect D05 -115 12256 46` Avenue South The Planning Division of DCD has reviewed the above permit application that was submitted on May 26, 2005. Planning cannot approve the application due to the following: 1. The Garden Window on the south elevation extends into the setback area. The only item permitted to extend into the setback areas are roof eaves. 2. It appears that the lot being built on was used for parking for the existing house. (12252 46`" Ave South). Where will the parking for the existing house be provided? i 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 • Phone: 206- 431 -3670 Fax: 206- 431 -3665 z H �w UO: NO. U) =. J cn LL. WO LL ¢ CO D, = Cy. F— _: z� �O z }-- �o U O cn W W LL �" _ O. .. z U Co; O z �vJILA, l O ' G) City �[ uk YY lla Steven M. Mullet Ma v f or Y Department of Community Development Steve Lancaster, Director 1905 CITY OF TUKWILA PUBLIC WORKS PROJECT REVIEW COMMENTS www.ci.tukwila.wa.us Development Guidelines and Design and Construction Standards Permit #: Project Name: Review #: Date: Reviewer: D05 -115 Watanabe SFR 12252 46` Av. S 2 06.13.2005 L. Jill Mosqueda, P.E. The City Of Tukwila Public Works Department (PW) has the following comments regarding your application for the above permit. Please contact me at 206.431.2449, if you have any questions. 1. PW issues a Type C permit as part of the building permit. For the Type C permit, PW collects a base application and plan review fee when the application is submitted. The fee pays for two reviews. Public Works charges for additional reviews. 2. The Public Works'Development Guidelines and Design and Construction Standards is available at www.ci.tukwila.wa.us Please provide the following items, most of which were requested on 04.27.2005: a) Provide a percolation test using the EPA Falling Head method, available in the Public Works s standards and on the website at http: / /www.ci.tukwila .wa.us /pubwks /pwpermit.htm Footing drains and roof downspouts must be separate systems. b) Because this area is flat, Public Works looks very closely at the elevation changes to avoid creating drainage problems. Placing 66 CY of fill in the driveway will raise the elevation almost 3 feet. This will not work. Please provide a design that will work. 3. Do you really intend to install an 8" water line to the property? The usual size is V. 4. Provide a copy of the side sewer easement from the property to the north. 5. The pavement mitigation fee for the cut shown on the plans in $900. 6. Provide the items required for work in the right -of -way per Bulletin A6 that is available on the City's website at: hag.- Ilwww. ci. tukwila. wa. us1bubwks 1p wpermit. htm 7. 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 -431 -3665 C,':�, _ _�,« _ri::.�.ac. a�:. wuvw.ta:,rt ».:::.Lt.,a i:., �.j:.+.»�:: .:ai,ir�;;�l.ia:.: x' ir)s9!rSli49" m Z '~ w D UO N J = F-- N LL wO LL ¢ C0 D T o �- w Z f - O Z �5 U� O N w �- O w Z U= o z .i , -tIl/ City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director �soa Z May 11, 2005 w D JU Mr. Mark Travers 0 0 2315 East Pike Street Seattle, WA 98122 N ►_- U- Uj — O RE: CORRECTION LETTER #1 �. Development Permit Application Number D05 -115 :3 Watanabe Residence -12256 46 1 ' Avenue South N s Dear Mark: z H This letter is to inform you of corrections that must be addressed before your development permit(s) can be approved. w All correction requests from each department must be addressed at the same time and reflected on your drawings. I O- 5 have enclosed comments from the Planning and Public Works Departments. At this time, the Building and Fire v c co Departments have no comments. 0 1- wr Plannin Department: Brandon Miles, at (206) 431 -3684, if you have questions regarding the g U attached memo. p' W Z Public Works Department: Jill Mosqueda, at (206) 431 -2449, if you have questions regarding the U attached memo. p H Z Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) complete sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 433 -7165. Sincerely, • .rte' Stefani Spencer Permit Technician encl xc: File No. DOS - 115 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206. 431 -3665 O X City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director W: JU 0 0:1 W W U. 0 PLANNING DIVISION COMMENTS Uj DATE: April 14, 2005 LL < CONTACT: MARK TRAVERS cl) cf RE: D05-115 UJ ADDRESS: 12XXX 46 Ave South X z P� 0 : The Planning Division of DCD has reviewed the above pen applications that were submitted on W LU April 11, 2005. Planning cannot appiove the application because the application does not comply D 5 with applicable development regulations: 0 C0 1. The site map shows that the fireplace will intrude into the side setback area. The fireplace UJ UJ m ust meet setbacks. U- O (0 , L) 3: 0 z CITY OF TUKWILA PUBLIC WORKS PROJECT REVIEW COMMENTS www.ci.tukwila.wa.us Development Guidelines and Design and Construction Standards Permit #: D05 -115 Project Name: Watanabe SFR 122XX 46" Av. S Review #: 1 Date: 04.27.2005 Reviewer: L. Jill Mosqueda, P.E. The City Of Tukwila Public Works Department (PW) has the following comments regarding your application for the above permit. Please contact me at 206.431.2449, if you have any questions. 1. PW issues a Type C permit as part of the building permit. For the Type C permit, PW collects a base application and plan review fee when the application is submitted. The fee pays for two reviews. Public Works charges for additional reviews. 2. The Public Works' Development Guidelines and Design and Construction Standards is available at www.ci.tukwila.wa.us 3. Conditions at the site include one sewer stub to the property line, an open ditch along the frontage and a power pole in front of the proposed location for the house. According to City records, there is no water stub to the property line for this parcel. 4. Please provide one site plan that shows: a) All existing items in the right -of -way. b) All work related to all utilities ( water, sewer, power, cable, gas), C) Underground power from the pole onto the site. Show it on the plans. d) The work required to enclose the ditch in 46` Av S. Include the frontage along this lot and the lot to the north. This is required by TMC 11.12. Include materials, sizes, slopes, bedding, elevations, etc. Provide all information necessary for installation and for inspection. e) Erosion Control Best Management Practices. f) Show what the driveway catch basin will connect to and show how it will connect. (If you expect to infiltrate the roof downspouts, provide a percolation test using the EPA Falling Head method, available in the Public Works standards and on the website at httl2:HwwNv.ci.tukwila .wa.us /pubwks / yXermit.htm g) Paved connection from pavement in 46`" AV. S to the paved driveway. Show the culvert, the turning radii at the right -of -way connection, and the material. h) Existing and proposed elevations, i) Expected cut and fill volumes (in cubic yards). Zero is not acceptable. sks Page 3 TALinks\Docs\D05- 115\D05 -115 - Correction Letter #1.DOC 05/12/2005 Z Z u�l 7- UO 0 co LU J H LO o w� J t1- co =w �o Ui z� U� O N o E- w F- F, Lo w z U= z G j) Amount of cut volume ( in cubic yards) that will go in the driveway. k) Elevation difference due to expected fill. 1) Erosion prevention Best Management Practices, M) All work in the right -of -way, including enclosing the ditch (TMC 11. 12.080) and connection to the water main. 5. Provide the items required for work in the right -of -way per Bulletin A6 that is available on the City's website at: http://ww%v.ci.tukwila.wa.us/pubwks/Snermit.htm r sks Page 4 T:\Links\Docs\D05- 115005 -115 - Correction Letter #I.DOC 05/12/2005 Z F z W UO W =. CO LL U1 O; -J. L a co d _` z �. O' z �--. w Do o �: w w F- L ..z UN b F=—; O Z ( PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER D05 -115 DATE: 8 -30 -05 PROJECT NAME WATANABE RESIDENCE SITE ADDRESS 12256 46 AV S Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 3 Revision # After Permit Issued DEPARTMENTS Yvl x$10 Building Division ❑ Fire Prevention ❑ Planning Division ie Public Works Structural ❑ Permit Coordinator 17 AAA All S r ref n r� DETERMINATION OF COMPLETENESS (Tues., Thurs.) DUE DATE: 9 -1-0 Complete Ef Incomplete ❑ Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS 7 ING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: ! APPROVALS OR CORRECTIONS DUE DATE: 9-29-05 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing sllp.doc 2 -28.02 z ;= z �W D �U UO CO C3 w= WLL WO LL = � =W �_ Wo LLJ G 5 U� O CO 0 f- WW UO z W U= O~ z PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER D05 -115 DATE: 7 -28 -05 PROJECT NAME WATANABE RESIDENCE SITE ADDRESS 12256 46 AV S Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 1 Revision # After Permit Issued DEPARTMENTS Building Division ❑ Fire Prevention F Planning Division Public Wo ks Structural ❑ Permit Coordinator LA DETERMINATION OF COMPLETENESS (Tues., Thurs.) DUE DATE: 8 Complete ❑ Incomplete ❑ Not Applicable Pp ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS RO TING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS Approved ❑ Approved with Conditions ❑ DUE DATE: 8 Not Approved (attach comments) ;/ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: S tai: - Departments issued corrections: Bldg ❑ Fire ❑ Ping [ PWP. Staff Initials: Documents /routlng shp.doc 2 -26.02 z ~w �U 0 N CO W J H 2 wO cf)d =w z z o 25 D U O� 0 F- wW �- O ..z W co O z PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: D05 -115 DATE: 05 -26 -05 PROJECT NAME: WATANABE RESIDENCE SITE ADDRESS: 1225646 TH AVENUE SOUTH Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 1 Revision # after /before permit is issued DEPARTMENTS Building Division ❑ Fire Prevention ❑ I ning Division A Public Works „ Structural ❑ Permit Coordinator (AYV) dmy &, /� -O. DETERMINA ON OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 05 -31 -05 Complete Incomplete ❑ Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS R TING: Please Route 9 Structural Review Required REVIEWER'S INITIALS: ❑ No further Review Required DATE: APPROVALS OR CORRECTIONS Approved ❑ Approved with Conditions ❑ Notation: IN DUE DATE: 06 -28 -05 Not Approved attach comments PP ( ) REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: 1p 5 Departments issued corrections: Bldg ❑ Fire ❑ Ping x PWX Staff Initials: PEMWIT COORD COPY Documents/routing slip.doc 2.28.02 t z ~w � UO CO 0 C0 W J F— Cf) U. w U.a Cl) D = �_w z t- f.. O zF- LU LLJ U� O- o E- w W HF_ LL 0 ..z W U= O z PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D05 -115 DATE: 04 -11 -05 PROJECT NAME: WATANABE RESIDENCE SITE ADDRESS: 1C 46 AVENUE SOUTH X Original Plan Submittal IUD Response to Incomplete Letter # Response to Correction Letter # Revision #_after /before permit is issued DEPARTMENTS. ! / /nn Bui i Division Fire Pkvention (� Pld'nning Division Q Public Wo&k L_ L Rk r i t �_ / Structural ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete ❑ Comments: Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS R UTING: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: ❑ No further Review Required DATE: DUE DATE: 05 -10 -05 ❑ Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: � Departments issued corrections: Bldg r_1 Fire El Ping( PW Staff Initials: Docu ments/routing sllp,doc PERMIT C O O R D COPY 2.28 -02 DUE DATE: 04 -12 -05 z w. i� JI U UO W 3: NU_ w° U_ _ =W H z� ZO LU5 U� O cn. o�_ Ww U- O W z U= O z City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206- 431 -3665 Web site: http: / /www.ci.lukwila.wa.us Steven M. Mullet, Mayor Steve Lancaster, Director SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail fax ptr.. Date: - Plan Check/Permit Number: ❑ Response to Incomplete Letter # [?� Response to Correction Letter # _ I ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: w K )ez /JI Project Address: 22__ �Co -1 XAAg�, S Contact Person: _ •'"� /�,C Phone Number: "-O G & Summary of Revision: lit (, . 2 �' • 0 2 4 - lrz--. 30 RECEIVED .. nr 0 26 .S PERMIT CENTER Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: P Entered in Permits Plus on pplications orms- applications on Ime evision submittal Created: 8 -13 -2004 Revised: z �W D JU UO N W = H to LL WO LL Q CO D = d �w z F— O z 1— w U� CO o� W LL O z w U= O F- z ..M ..:. v::. u=.: we��..:.. j�.-.. L..> w.:. w;:: 1o:.: .4.i:+::..d.:.'�:rr.u..�iys::: y.:.:. x. is�t'.. 4. t.•! n', iRiza.. Y .:+ah.:s�:.M:wrw:N«:'Avtf.:iu•n r;L a.�rs..,eN v,5:••w v wv.5.w.iti: .i1 w+s.:os:N,.ir,.l�+i'i++' "• ILA, �, City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 N `�= Tukwila, Washington 98188 Phone: 206 -431 -3670 1908 * Fax: 206 - 431 -3665 Web site: http : / /www.ci.tukwila.wa.us Steven M. Mullet, Mayor Steve Lancaster, Director .M 'REVISION STBMITTAL .., Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. ` Date: 2 Plan Check/Permit Number: DS � ❑ Response to Incomplete Letter # Response to Correctibn Letter MO Revision # after Permit is Issued Revision requested by a City Building Inspector or Plans Examiner Project Name: Project Address: L 2 2 C(OL Contact Person; Phone Number: 2 aCo 7 Summary of Revision: S1L > L�� n _ AECE _ - 0" Or- r JUL PERMIT CENTER Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: 6 L&W [ Entered in Permits Plus on pp icatior►s\forms -app ications on me evision submittal Created: 8 -13 -2004 Revised: z �Z k- w rY 2 D JU 0 to 0 CO ul, W= to LL WO J u- Q = �w z Z0 U O Co. o I— =U u.- O .z co O z City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Steven M. Mullet, Mayor Steve Lancaster, Director REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 05 4K Plan Check/Permit Number: ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # A ❑ Revision # after Permit is Issued �oS -115 ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Project Address: LFC N S Contact Person: M= rtll� Phone Number: Summary of Revision: ~ i�.S IS M t 1�1 `MT ( `��L MyS� -�-� Ik /h/�►1� M�'1.L, �,l -�.' � Sc -M1-t ire ►�� � -�u�- t'�� , ��`1�9� �r�, CIT RECEI MAN7r - MIT CENTER Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: ..Y7 11� Entered in Permits Plus on ^dS' pp ications orms -app ications on line ewsion submittal Created: 8 -13 -2004 Revised: Z '~ w JU UO 0 W= LL , .W .w L L to D = a. �w z X I— O w ~ w 5: U� O CO o h_ wW .L O w Z to O Z Look Up a Contractor, Electra, an or Plumber License Detail Pagel of 2 https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= SKYWAHI0020J 11/03/2005 I Washington State Department of Labor and Industries General /Specialty Contractor A business registered as a construction contractor with L &1 to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. License Information License SKYWAH10020J Licensee Name SKYWAY HOME IMPROVEMENT INC Licensee Type CONSTRUCTION CONTRACTOR U BI 602062377 Ind. Ins. Account Id Business Type CORPORATION Address 1 PO BOX 4084 Address 2 Cancel City RENTON County KING State WA Zip 98057 Phone 2067721886 Status ACTIVE Specialty l GENERAL Specialty 2 UNUSED Effective Date 9/11/2000 Expiration Date 9/18/2007 Suspend Date Separation Date Parent Company Until Previous License ALLSEH1053K2 Next License Associated License Business Owner Information Name Role Effective Date Expiration Date NO, RAYMOND 01101/1980 Bond Information Bond Bond Company Account Effective Expiration Cancel Impaired Bond Received [Bond Name Number Date Date Date Date Amount Date AMERICAN STATES INS Until #3 CO 6310625 10/05/2004 Cancelled $12,000.00 " i 10/08/2004 WESTERN Until i i I I Z = Z LU JU UO Co 0 co W J U) W WO 2� UQ N� =Cl �W Z F-. ZO W 5: U� ON 0 1— WW �U LL ~ O Z W co O Z NOTE: REFERENCE DATUM i ELEVATIONS ARE ASSUMED IBC 2003 IRC Abbre viati S/A SUPPLY AIR UPC OnS STRUCT STRUCTURAL A F F _ ABOVE FINISH FLOOR 5W _ SHEAR WALL A B ANCHOR BOLT TEMP TEMPERED GLASS ABV _ ABOVE T &G TONGUE & GROOVE ADD'N _ ADDITION T.O.S. TOP OF SLAB ADD 'L ADDITIONAL - T. 0. P. TOP OF PLATE AV` - - AVERAGE T.O.W. TOP OF WALL - .- - - - BLW BELOW - - TYP TYPICAL BMS BEAMS VERT VERTICAL BM BEAM -. - -. - -- - -- _ _ - V T 0 - -- -- .._._. - VENT TO OUT SIDE BOT _ ^ -- - - - BOTTOM V-13 VAPOR BARRIER - B.S.B.L. BUILDING SETBACK LINE V.G. - VENEER GRADE - CB CATCH BASIN V.C.T. VINYL COMP. TILE C ONC CONCRETE _ w/ D WASHER / DRYER CONTIN - - CONTINUOUS W.F. WIDE FLANGE BEAM COMP _ COMPOSITE W.W.F. WELDED WIRE FABRIC - CAB - -- - -- CABINET w/ WITH CLG CEILING CLR CLEAR COL _ COLUMN C.J. _ _ CONTROL ,JOINT CPT CARPET CER CERAMIC - - -_ - -- - -- -.__ __ _- - - --- - --- -- -- -- -- -- -- ---- -_ CONTR CONTRACTOR D.O. _ _ _ DUPLICATE OTHER DISP DISPOSAL DN � - - -- - -- DOWN - - - - -- - - -- -- ---- - -_ -__ __- - - D.F. DRINKING FOUNTAIN - DS Dw __ -- DOWNSPOUT ._ _-- - - - - -- Sy mbols DISHWASHER EA EACH _ _ SECTION ELEV ELEVATION - -- --- -- - - _� EQ _ - -� _ EQUAL X WALL SECTION EQUIP _ _ EQUIPMENT -T ' DETAIL EQUIV _ EXIST EQUIVALENT _ - -- EXISTING - - - - - - - -- - - -- - - -- - - POINT ELEVATION - EXT _ EXTERIOR - �_ �}� +• -� EXISTING CONTOUR - - -- FDN - - - FOUNDATION -- - -- ---- TO BE REMOVED _ _ F.D. -- --- -- FLOOR DRAIN - _ _ • � ' _ EXISTING CONTOUR TO BE REMAIN F.E. — _ FIRE EXTINGUISHER NEW CONTOUR FTG FOOTING - - - - - - -- - -- FURN _ _ _ __ _ FURNACE DOOR (EXISTING) F.F.E. - FINISH FLOOR ELEV -_ Q DOOR (NEW) F. F. _ _ FINISH FLOOR -� WINDOW ( EXISTING) F. P. - -- FIREPLACE FIN FINAL <X -- - WINDOW (NEW) - -- - -- - F.O.S. FACE OF STUD - - - -- - - - -- -- F.O.W. - _ _ _ - FACE OF WALL SWx SHEAR WALL PER SCHED GA GAGE SD SMOKE DETECTOR - GALV GALVANIZED MECH. FIXTURE -- G.I. GALV. IRON _ _ _ Mx - PER SCHED. GR GRADE E ELECT. FIXTURE _ _- GLB -` GLU LAM BEAM - - -- -__ PER SCHED. - GWB GYPSUM WALLBOARD ® CB CATCH BASIN GYP GYPSUM �— SOLID BLOCKING i HDWD - HARDWOOD - TO FOUND. BELOW -- - - Px PLUMBING FIXTURE HORIZ HORIZONTAL PER SCHED. H.W. HOT WATER - _ MATCH LIC a MA TCH LINE INSUL _ INSULATION �c- - - - - - -- - -- LONGIT LONGITUDINAL ® CFM EXHAUST FAN MAX MAXIMUM T EXIT SIGN -- M!N -- - MINIMUM -- -- MANUF -- MANUFACTURER - -- -- - -- +F.D. FLOOR DRAIN MECH - MECHANICAL r : FIRE EXT. M.H. MAfU HOLE - - - - -- - - - - -- N - - - -- NUM - - -- -- -- 0 7 TEE CENT DIN t� Pt." pERFORA; El!-` - - -- -- - - -- - - - - _ _- -- Y -- ;C" Nr Sim S*1mL* — - -- S S JAF t,R 'X riE.. -LE — - S = SW'*. E IE C- -- -- NOTE: REFERENCE DATUM i ELEVATIONS ARE ASSUMED From Yard Seim& 'Pmr, n Scale Vl--w4 r PLAN VIEW NTS infiit ation tre dra in i . 4' rice(; or 6 tloxible. pe�t� ►r��tE�d pipe SUM Wl"i -Oh f lid PLAN VIEW -r oof dra NTS overflow 4 ' rigid or o' flexiMe, splash block perforated pipe - N V , was`�ed r, "�t:k r ~'-, �J' }� Emil 5_p�n��n 4 mi n fine mesh screen `--- CB sump w /sold lid 9 - -1 miry -+- A Biter tabrIC IBC 2003 IRC 2003 compacted backfi =1 2003 UPC 2003 6 " : ") _ _ L L y _ , r perforated p ipe CL I I — , r-.• washed rock r _ • DRn SW AY _ r ,! . 24' oc From Yard Seim& 'Pmr, n Scale Vl--w4 r PLAN VIEW NTS infiit ation tre dra in i . 4' rice(; or 6 tloxible. pe�t� ►r��tE�d pipe SUM Wl"i -Oh f lid PLAN VIEW -r oof dra NTS overflow 4 ' rigid or o' flexiMe, splash block perforated pipe - N V , was`�ed r, "�t:k r ~'-, �J' }� Emil 5_p�n��n 4 mi n fine mesh screen `--- CB sump w /sold lid 9 - -1 miry -+- A Biter tabrIC SECTION A NTS Perforation Tightline Connection Scale: NTS go Mom N ch "mft shalt be tilt de Of '"CA �� c y� .•, [( > �] f �� tl � �� a �� �� Tijk Um ft1d"Aa C lYw.V�w ' r NOTE: Revisions trill require a new plan submtW and may 1ndude addbonal plan rev;•ew fees. j Plans bare h er -n rcvirw(%d by tier V or Department for conformincc « r';, s%mlards. Acceptance is su; to crrnrc and rIi i «ions which do not authorize -v•iolati,n, of s:'orted standards or ordinances. The rerpomihility for the adequacy of the design restt totally wit'i the des - ;finer. Additions, deletions or m to thccc dr :w.inRe after this date v611 void this acceptance a7 -d Will require a resubmittal of revised draR-inbs for s ihsequent approval Final acceptance is subject to field inspection by ,he Public Forks utilities in n tc: B 9 Z owl Idim FILE � rte. 1 1-Ar P11" miew qV ov4 iS 940a dD !'fT+ n and AW "aI of does not the violation of arnr ad�opR,led or cpde o ��� of approved Field Copy aml ado � - BY - aft I +116-10 m + 116.25' +116-50 I EXIST. /FIN. ;r) ) "' EXIST. GR. FIN. GR. _ -- GRADE J MAIL ` N 89017'24' W PROP. LINE 100. N 00' ' BOXES - — — -- W \� EXISTING '� PJWER POST _= _ _ : 5 8.S.8.L _ f +` � � � • as N , _ .. -- _ . r � i _ o CONC. UP _ : _ : _. _ '. 1 ? � e CL c WALK t ! �. - __ _ - P S'F WFTH ' __� _ GUTTER, TYP. to I _ - - _t5 G -- -- - - - -_ - - 0 # �& -o $ _fl t REM SETBACK F 0. W' I FRONNT SETBACK o i IE ` GF + ;, - ' - - % - ., GARAGE F F. mil. _ :. _ r o 00 N 1" 111 cn ......- . - - - • - - - E7 G R IVE e3 _ _ .. I ST F.F.E. _ - :. ,o t,� w ' METE +11&20 .-• t ' . _ a IL •:6 f �.f ::;�w � t ��1. N 890 1724' W PROP UNE 100-W 1 E > E� IST.; < EXIST-/ FtN. E -S7j.Nk-- FiN. CR- W C.R. 'S,AkITAP`t SEVER r SEP K TAW TO BE DEMOLISH � f MAHMiOL f � AS KR #W4 -388 1 ! f m scalie:1%0a0 PROJECT: SINGLE FAMILY RESIDENCE 122XX 46TH AVE S TUKWILA, WA OWNER JAMES WATANABE 5916 18TH AVE S SEATTLE, WA 98108 (206) 226 3193 CONTACT: JAMES WATANABE ARCHITECT /AGENT: MARK TRAVERS ARCHITECT 2315 E PIKE ST SEATTLE, WA 98122 (206) 763 -8496 CONTACT: MARK TRAVERS SCOPE OF WORK: NEW CONSTRUCTION OF SFR W/ (2) CAR ATTACHED GARAGE CONSTRUCTION TYPE: V -B ZONE: LDR OCCUPANCY: R--3, U -1 TYPE OF HEAT: GAS HEATING APPLICABLE CODES: 2003 IBC 2003 IRC 2003 compacted backfi =1 2003 UPC 2003 6 " : a'. rigid nr 6" flexible _ O _ ., perforated p ipe i ,.� :.., : _ •` -, y washed rock 1 1 u 24' SECTION A NTS Perforation Tightline Connection Scale: NTS go Mom N ch "mft shalt be tilt de Of '"CA �� c y� .•, [( > �] f �� tl � �� a �� �� Tijk Um ft1d"Aa C lYw.V�w ' r NOTE: Revisions trill require a new plan submtW and may 1ndude addbonal plan rev;•ew fees. j Plans bare h er -n rcvirw(%d by tier V or Department for conformincc « r';, s%mlards. Acceptance is su; to crrnrc and rIi i «ions which do not authorize -v•iolati,n, of s:'orted standards or ordinances. The rerpomihility for the adequacy of the design restt totally wit'i the des - ;finer. Additions, deletions or m to thccc dr :w.inRe after this date v611 void this acceptance a7 -d Will require a resubmittal of revised draR-inbs for s ihsequent approval Final acceptance is subject to field inspection by ,he Public Forks utilities in n tc: B 9 Z owl Idim FILE � rte. 1 1-Ar P11" miew qV ov4 iS 940a dD !'fT+ n and AW "aI of does not the violation of arnr ad�opR,led or cpde o ��� of approved Field Copy aml ado � - BY - aft I +116-10 m + 116.25' +116-50 I EXIST. /FIN. ;r) ) "' EXIST. GR. FIN. GR. _ -- GRADE J MAIL ` N 89017'24' W PROP. LINE 100. N 00' ' BOXES - — — -- W \� EXISTING '� PJWER POST _= _ _ : 5 8.S.8.L _ f +` � � � • as N , _ .. -- _ . r � i _ o CONC. UP _ : _ : _. _ '. 1 ? � e CL c WALK t ! �. - __ _ - P S'F WFTH ' __� _ GUTTER, TYP. to I _ - - _t5 G -- -- - - - -_ - - 0 # �& -o $ _fl t REM SETBACK F 0. W' I FRONNT SETBACK o i IE ` GF + ;, - ' - - % - ., GARAGE F F. mil. _ :. _ r o 00 N 1" 111 cn ......- . - - - • - - - E7 G R IVE e3 _ _ .. I ST F.F.E. _ - :. ,o t,� w ' METE +11&20 .-• t ' . _ a IL •:6 f �.f ::;�w � t ��1. N 890 1724' W PROP UNE 100-W 1 E > E� IST.; < EXIST-/ FtN. E -S7j.Nk-- FiN. CR- W C.R. 'S,AkITAP`t SEVER r SEP K TAW TO BE DEMOLISH � f MAHMiOL f � AS KR #W4 -388 1 ! f m scalie:1%0a0 PROJECT: SINGLE FAMILY RESIDENCE 122XX 46TH AVE S TUKWILA, WA OWNER JAMES WATANABE 5916 18TH AVE S SEATTLE, WA 98108 (206) 226 3193 CONTACT: JAMES WATANABE ARCHITECT /AGENT: MARK TRAVERS ARCHITECT 2315 E PIKE ST SEATTLE, WA 98122 (206) 763 -8496 CONTACT: MARK TRAVERS SCOPE OF WORK: NEW CONSTRUCTION OF SFR W/ (2) CAR ATTACHED GARAGE CONSTRUCTION TYPE: V -B ZONE: LDR OCCUPANCY: R--3, U -1 TYPE OF HEAT: GAS HEATING APPLICABLE CODES: 2003 IBC 2003 IRC 2003 IFC 2003 UPC 2003 WSEC Project Information TAX ID #: 0179000976 LEGAL DESCRIPTION: LOT 18, BLOCK 5, ALLENTOWN ADDITION TO THE CITY OF SEATTLE, ACCORDING TO THE PLAT THEREOF RECORDED IN VOL. 12 OF PLATS, PAGE 100, CITY OF TUKWILA, KING COUNTY, WASHINGTON Legal Description LOT AREA: BUILDING FOOTPRINT AREA: LOT COVERAGE: 4,000 SF 1,500 SF 1,500 < 2,275 SF vs per 18.10.057.5 TMC Project Calculations !SEPARATE PEmr POR: dr Fw>ta dcm 11r_ Rp P'�srtbi��g d G=P City Of Tukw - ;$" l IDIM DMSION V) i cry I W W . Q Q I S 124TH ST i S 1 %5TH ST Vidnilty Plan y REVIE�IV ED FOR CODE ComP LANCE s onomiln SP Of TLimv FMCBVW CYTY OF TUKWLA PF..IW cEWO 0 : 4 1 awl AL fh ,Imp of Reoad = Travers r Ard AA ~ Tot 20&76M - Foic 205426=6 2315 Emit P&B 9" - - Sias, WA am co r Fm O J c 1 � c» C L Ca Ed a� Fm o CO U CD CN __... N r � �pteche� UTT DOW OV2m A l S, pI Pf? : lTA • wA t. AND St R `hvE _ -' ST :,tOh^TR'J+L Fi,m �= F4?S LEVEL. SECOND LEVE` F PtWS A3 & SECT06. €FMS X44 FRA&W PW6 A5 ELEVATIOHS, SPECS SPECS PICAT06 sneer index Dos -►�s Al C 12 f1 nT, I cr•r SEDIMENT CONTROL FILTER FENCE �__ METAL FENCE POST'S i STANDARD PRACTICES E3.10 j PRESERVING VEGETATION -- FILTER FABRIC MATERIAL 60` MADE / BOILS USE STAPLES OR WIRE RINGS TO ATTACH FABRIC TO MARE MMRAFI 70OX OR PRE - APPROVED EQUAL TREE FENCING SHALL BE A MINMWM OF 4' HIGH ORANGE POLYETHYLENE LAMINAR SAFETY NETTING j r •'r X 2' X 14gO WIRE FABRIC OR EQUIV 1 6 ' \ �-- PROTECTIVE FENCING t (OPTIONAL -PER SITE CONDITION) POSTS SETTING TO 2 IN GROUND MADE OF DURABLE DURING CONSTRUCTION BURY BOTTOM OF FILTER MATERIAL IN 8 METAL - T - OR CQUIVALENT 1 X 12' TRENCH a s -0 _t —= MAXIMUM l j IT T 1 , — W WES_ - FILTER FABRIC MATERIAL I. 3 WOOD CHIP MULCH MAY BE ADDED FOR ROOT NOTE ANGLE SILT FENCE BACK UP THE .1 ? PROTECTION WITI�IN FENCED SLOPE AT THE END OF RUN. T`+ AREA. ° 2 OUTSIDE OF PROTECTIVE FENCING PROTECTED ROOT LONE wTI�IN THE _ `^ AREA, PROTECT ROOTS 2 -INCHES CANOPY DRIP UNE-ACTUAL FEEDER BACKFILL MATH NATIVE SOIL MATERIAL � OR LARGER IN DIAMETER BY USING ROOTS EXTEND MQL BEYOND DRIP OR GRAVEL BACKFR_L IN TRENCH AND HAND EXCAVATION TECHNIQUES. LINE ON BOTH SIDES OF FENCE 3. MINIMIZE CONSTRUCTION ZONE PROTECT FABRIC ON THE SURFACE VEGETATION OUTSIDE CONSTRUCTION ZONE BY SEGREGATING IT VATIJ HIGH VISIBILITY CONSTRUCTION FENCING. REASON _ T IISnxRBEDD AREAS DDUR oTSN o DECREASE VELoa S�T#ET FLOW FROM REASON TO REDUC EROSION BY PRESERVING NATURAL VEGETATION MAIfREVER PRACTICABLE. SYMBOL: Q - - -- - - - -- - - SYMBOL: VEG CONSTRUCTION ACCESS E2.10 LENGTH PER THE DPD SITE / DEVELOPMENT INSPECTOR GEO- TEXTILE FAEIRIC - ;N•._�, i; •• %�- .�- ;t !L STABILIZED ACCESS SHALL BE USED IN ALL AREAS OF THE SITE MNTN VEHICLE TRAFFIC AND PARKING, INCLUDING PLOW TTNG STRIPS. OTHER MEANS OF PROVIDING STABIUZED ACCESS WILL BE CONSIDERED. REASON . TO R��j S ��� E IRT• ETC. TRANsPm7m ONTO SYMBOL: — � COVER MATTING /ROLLED EROSION CONTROL PRODUCTS E1.15 STEEP SLOPE R E A S N : TG mv" MEDIATE PROTECTION TO Dwosm sO s maw THE PERIOD OF - - SHORT - CONSTR DELAYS - SYMBOL: �' - PLASTIC COVERING STOCrcds iE 1.20 ANCHOR >E�NTS SETH STANCES i . --STRAW IMTTIf A* i — 10' MA.X ,,—sa BErl -- STRAIT BALES CONVEY CONWY RUNW T. APPRGVQ ;ACADM an 7LMS 6JP` 9UTW iK 4 w 1 c Nk +PETMG A 4"C" NuG+� NTH STAKES WAILM()FrF % F" - ,DFOF ,SLOPE SAW1A. W"F M9M0 ROCK � AFPQO'C LOCAIM `, t 'ML1E EIE�G? t F�►�Ii► ,- -ONE So" ME%]Er • TXw3ErWwaw J� SLOPE W'- 1•ASir "A30k SsES 4rtC _ 1 bc =J . ftw-c- %-A :.Mer.r:1 BE e• 1MU►a t ri. TW T ��T -�L.. ���. `. `' CC % �C+� ' CNC E. I EALC ) LkRft r rk Now 1 1 5AS Olt 7'PtE - REF" � K A1LL cTC R P_h­1 I:Z� tc PLA % WhFkL IS COA P'..E 4 " -B' QUARRY SPALLS i El .25 ,.,--CANOPY DRIP LINE to __ - - - - -- •. 1 sir... �:.. -' ~..•� - - - ,�.•. �•r: � L- _- PROP. LINE 100.00' -L.QT 18 ep C!1 Q — STOCKPILE FF ; zo :t I = PROPOSED SFR WITH • :�,; • � � • :- , - : - . - I 2 CAR r a �� GARAGE $ r tr l I �0 i. PROP. LINE 100.00' Stormwater Control Plan Scale: 1"-10'-0* ON SHALLOW SLOPES, STRIPS OF NETTING MAY BE APPLIED ACROSS THE SLOPE NORTH SHALLOW SLOPE w (c3: t) JUTE MAT71MG OR OTHER 6" PVC TESTING BIODEGRADABLE UAIERW. ON STEEP SLOPES. APPLY STRIPS OF NETTING PARALLEL TO THE DIRECTION OF BERM THE FLOW AND ANCHOR SEAIREIY - - • - � 1, -� , � TEE (TT) MIEERE THERE IS A BERM AT THE TOP OF ~ THE SLOPE. BTiM% THE N TIMG OVER THE BERM AND ANCHOR R BEH>ND THE BERM STEEP SLOPE R E A S N : TG mv" MEDIATE PROTECTION TO Dwosm sO s maw THE PERIOD OF - - SHORT - CONSTR DELAYS - SYMBOL: �' - PLASTIC COVERING STOCrcds iE 1.20 ANCHOR >E�NTS SETH STANCES i . --STRAW IMTTIf A* i — 10' MA.X ,,—sa BErl -- STRAIT BALES CONVEY CONWY RUNW T. APPRGVQ ;ACADM an 7LMS 6JP` 9UTW iK 4 w 1 c Nk +PETMG A 4"C" NuG+� NTH STAKES WAILM()FrF % F" - ,DFOF ,SLOPE SAW1A. W"F M9M0 ROCK � AFPQO'C LOCAIM `, t 'ML1E EIE�G? t F�►�Ii► ,- -ONE So" ME%]Er • TXw3ErWwaw J� SLOPE W'- 1•ASir "A30k SsES 4rtC _ 1 bc =J . ftw-c- %-A :.Mer.r:1 BE e• 1MU►a t ri. TW T ��T -�L.. ���. `. `' CC % �C+� ' CNC E. I EALC ) LkRft r rk Now 1 1 5AS Olt 7'PtE - REF" � K A1LL cTC R P_h­1 I:Z� tc PLA % WhFkL IS COA P'..E 4 " -B' QUARRY SPALLS i El .25 ,.,--CANOPY DRIP LINE to __ - - - - -- •. 1 sir... �:.. -' ~..•� - - - ,�.•. �•r: � L- _- PROP. LINE 100.00' -L.QT 18 ep C!1 Q — STOCKPILE FF ; zo :t I = PROPOSED SFR WITH • :�,; • � � • :- , - : - . - I 2 CAR r a �� GARAGE $ r tr l I �0 i. PROP. LINE 100.00' Stormwater Control Plan Scale: 1"-10'-0* i I MI CA �' +' NEW w A f ! , - -- 4 SEA �c a uS _ — _ __--- __-- -- N 8 f 77 4 W PROP�t�IE 10� - -- - - � �, �.__�___.�._.__ --__ 1 r~ 4titiECj`c:� t _ NEW �a *A E `R EP IC ET Et R 4S PER j ,� I I Cly of "z � I TUk I SS , z I I La f .> - CC'dTRX 10R 00 NOT BC SE � CE UN E , wad, sewer 8, Pow use No PROJECT: SINGLE FAMILY RESIDENCE 12256 46th AV S (LOT 18) TUKWILA, WA APPLICANT: MARK TRAVERS ARCHITECTS 2315 E PIKE ST SEATTLE, WA 98122 (206) 763 -8496 CONTACT: MARK TRAVERS TAX ID #: 0179000976 LEGAL DESCRIPTION: LOT 18, BLOCK 5, ALLENTOWN ADDITION TO THE CITY OF SEATTLE, ACCORDING TO THE PLAT THEREOF RECORDED IN VOL. 12 OF PLATS, PAGE 100, CITY OF TUKWILA, KING COUNTY, WASHINGTON GRADING CALCULATIONS TOTAL CUT: ' ' 0 c TOTAL FILL:(" Cy � NET CHANGE: 0 cy NOTES: 1. CONTRACTOR IS RESPONSIBLE FOR HAULING THE AMOUNT OF FOUNDATION CUT (EXPORT 66.3 CY). 2. ALL GRADES SHOWN ARE EXISTING /FINAL UNLESS OTHERWISE yi�D R NOTED +" Cm 0N �U1LP ;S 122TN ST t 4- ,rL:, PEROT COffM I r d Q S f 24TH ST I S ► 25TH ST k*v Plan i►: °..i�h�`f.►:A�l�! wi+.ii.i� :1r�t.ilr� . ; Swm of Am Mark Travers &A • Td: 2W?63M Falc 2315 EM PMIe SMMt ��. SMINK WA m _V! •- Y CIO r FI_ O CD C0 — CC Q � C) CO U CD L0 cl N —_ N qr""' �pppopp •Drat JHK w1T .Aa - Sti��l l R�ii�bris .�..� J A7.7 L] 12 MIN. THICKNESS = NORTH w 6" PVC TESTING - - • - � 1, -� , � TEE (TT) XIST i `/i . - -6 PVC WASHED >n 16 PVC _ C _ » 'C NEW 4 0 SS ROCK 6 i EXIST ,� y--r (CO) - - - - --• DEEP TYP. . - -- 60 •• � — ' �. ;' - -4" 0 DS - N 89� 17'24' W PROP. LINE 100.00' � 4"0 DS V) 4 "0 PERF. - -6 — p' _ . t_.. � ........� . ....... . ,�.�..� .— FOOTING GRAIN C0 > 00 MB PP- Y MIN. �" �g 4 0 py&- =- t 6' —6* PVC I I ' I V) a v, ! ! �— _ �• i $ __SEE R i DETAIL CLF�N —OUT - I - ' 6'X6'X3' INr =IL. PROVIDE I LLJ ,W — __ _ i' PIT. POSITIVE - . = ♦1 c0 I C8 w 1 /A1 - OV `•• _ _ O>rERh._AD - - r i ' .DR DRAINAGE FROM FTC. "' . , POWER $t - - -- - - ` DRAIN TIGHT -INE TO NEW Cg - � - -TELEPHONE I • 1 FOUNDATION LINES C �)F�I`�ECT a: � 1 �j I 1 0 1 1 g I uLVER I a » Pti 6 I • 6 sL1 r i PR I�OSED S R W 't� (2) '• a z i L ` E �_nUT CAR GALA : t J - WAGE EEli LOT 18 0 - e a i I MI CA �' +' NEW w A f ! , - -- 4 SEA �c a uS _ — _ __--- __-- -- N 8 f 77 4 W PROP�t�IE 10� - -- - - � �, �.__�___.�._.__ --__ 1 r~ 4titiECj`c:� t _ NEW �a *A E `R EP IC ET Et R 4S PER j ,� I I Cly of "z � I TUk I SS , z I I La f .> - CC'dTRX 10R 00 NOT BC SE � CE UN E , wad, sewer 8, Pow use No PROJECT: SINGLE FAMILY RESIDENCE 12256 46th AV S (LOT 18) TUKWILA, WA APPLICANT: MARK TRAVERS ARCHITECTS 2315 E PIKE ST SEATTLE, WA 98122 (206) 763 -8496 CONTACT: MARK TRAVERS TAX ID #: 0179000976 LEGAL DESCRIPTION: LOT 18, BLOCK 5, ALLENTOWN ADDITION TO THE CITY OF SEATTLE, ACCORDING TO THE PLAT THEREOF RECORDED IN VOL. 12 OF PLATS, PAGE 100, CITY OF TUKWILA, KING COUNTY, WASHINGTON GRADING CALCULATIONS TOTAL CUT: ' ' 0 c TOTAL FILL:(" Cy � NET CHANGE: 0 cy NOTES: 1. CONTRACTOR IS RESPONSIBLE FOR HAULING THE AMOUNT OF FOUNDATION CUT (EXPORT 66.3 CY). 2. ALL GRADES SHOWN ARE EXISTING /FINAL UNLESS OTHERWISE yi�D R NOTED +" Cm 0N �U1LP ;S 122TN ST t 4- ,rL:, PEROT COffM I r d Q S f 24TH ST I S ► 25TH ST k*v Plan i►: °..i�h�`f.►:A�l�! wi+.ii.i� :1r�t.ilr� . ; Swm of Am Mark Travers &A • Td: 2W?63M Falc 2315 EM PMIe SMMt ��. SMINK WA m _V! •- Y CIO r FI_ O CD C0 — CC Q � C) CO U CD L0 cl N —_ N qr""' �pppopp •Drat JHK w1T .Aa - Sti��l l R�ii�bris .�..� J A7.7 L] 12 MIN. THICKNESS = i I f CONTIN. BEAM ON RIM JOIST -� SECOND FLOOR CONTIN. BEAM 0 RIM JOIST -� 8d NAILS @ 3" O.C. STHD 14 @ SLAB ON GRADE, STHD14RJ @ CRAWLSPACE. INSTALL AS PER MANUFACTURER'S INSTR. AT EACH END OF PANEL. END DIST. FIRST FLOOR Alternate Braced Wall Panel Scale: 114 -1 0 E Isometric #, 2' -8" MIN. A OSECOND FLOOR CONTIN. BEAD ON RIM JOIST (2) 2X STUDS ---�- 8d NAILS @ z • J �• ( 0; L PLATE NAIL Sii AT±�,'!�O Tv EACH - 17 F :RSt F' "R I �--- STHD 14 @ SLAB GRADE, S i HD 14P_ � CRAwLSPA�c. a ItYST AL 4 1 - AS PER MAN-jFAC + UREF -�` IINSTR_ AT Ems., __ OF PANEL_ ENZ �jt� K (3 ) '.' tea_ 7" EMBED 4 ' MIN_ I I Aftemale ___ed WaM Panel safe: tK��•� 4 4 4 � _O �, I 5 p _ Jf i 00 1 i I I I o A3 A3 r 0 N Cq L I i O I Ln _ i ; f i M - ' 0 C) o' NN 1. ALL EXTERIOR DOORS (OPAQUE) TO BE 0.20 Uo MIN. W/ DEADBOLT W/ MIN. 1/2 THROW 2. ALL SMOKE DETECTORS TO BE 110V INTERCONNECTED W/ BATTERY BACKUP 3. SEE SHEET A4 FOR SHEARWALL NOTES & SCHEDULE 4. ALL LOWER FLOOR WINDOWS TO HAVE SECURITY LOCKS, TYP. O' i =�- o e- k , � 1C> I} P 3 Traver CrtP�r9rMt . �- CID C) O I 0 N Cq L I i O I Ln _ i ; f i M - ' 0 C) o' NN 1. ALL EXTERIOR DOORS (OPAQUE) TO BE 0.20 Uo MIN. W/ DEADBOLT W/ MIN. 1/2 THROW 2. ALL SMOKE DETECTORS TO BE 110V INTERCONNECTED W/ BATTERY BACKUP 3. SEE SHEET A4 FOR SHEARWALL NOTES & SCHEDULE 4. ALL LOWER FLOOR WINDOWS TO HAVE SECURITY LOCKS, TYP. O' i =�- o e- k , � 1C> I} P 3 Traver CrtP�r9rMt . �- CID 0 � o -memo C t > Q Co Co V � CD w N CN r � ii- cam: 05r19W r r r 100 CFM i I KITCHEN R LIVING - - - �- `20 Oil U_L. USTED FIREPLACE A A - -°+- -- _- - �--_ - -- -- - - A A3 A3 L , �A3 HEARTH o I' AT 5/8- TYPE 'X' GWB 3 ' j ALL WALLS, COILING. BEAUS & COL, TYP. i - f y EJ. _ g`_0' ._G. E f 2 2 -0 _ t k � _y 30 *-O F wst i .008 SF E.rvrrrG FksOr Plan GIAP**a 4 23 SF SC@hL IWJKIH ,r 8 '_ 0 1' 80 6a R 3 L . i - I SLlGE O j i j� Z i �- �ELAST ` +36' DECK I C> ^ � R # 4 - CGU& DRAIN lift 16� -0 ` 8' -0 _ 3' -0 EQ ' -J" I EG_ 3' - . �►c+" ---�' — - -� / / - / - - ar 10 t� 13 a T 30 ' L!'V c 1,444 SF ICS FI&AA p1 DECK 102 SF scow 114 -W NMIH r �- :T � �-- Y EXT. PLYWD. ON (1) SIDE AT 2ND FLOOR ONLY - (2) MST48 0 2ND FLOOR (ONE PER PANEL END TYP.) Y2 EXT. PLYWD. BOTH SIDES @ 1 ST FLOOR -- (3) 2X PLATES NAIL SHEATHING TO EACH �--- (3) " 0 A.B. 7" EMBED " EXT. PLYWD. ON (1) SIDE AT 2ND FLOOR ONLY (2) MST48 @ 2ND FLOOR (ONE PER PANEL END TYP.) r y M. PLYWD. BOTH SIDES @ 1 ST FLOOR OR :11 u") B I L i I A A3 I � o� co tf) i { I 4 - - 10 I r O ,p I A '- o� Co 70 I fi 6 -0 „ - -- 4' - i i Window Schedule SYMBOL _ MANUFACTURER SIZE (R.O.) TYPE QUANTITY ( T.G.A.(S.F.) I Uo REMARKS A 1 -0" x 6 -8" FIXED 7 0.40 I TEMP. GLASS MILGARD 920 1 B _ 8' -0" x 6' -8" SLGD 1 53 _ TEMP. GLASS " 1' - 6" x 4' -0" FIXED 2 12 " D , 3 f -0 q x 4, -0" � 2 24 ., - -- _ - - -- -- - FIXED E 060106 6' -0" x 6' -8" SLGD 1 40 , TEMP. GLASS F 5' - 0" x 4' -0" SLIDER 4 � 80 G > 6' -0 x 4 SLIDER 1 24 H 4' -0" x 4' -0" SLIDER 3 48 TEMP. GLASS I 8' -0" x 4' -0" 1 32 " " SLIDER K .� � .. t ELIMINATED 3 ' -0 " x 5 ' -0 " FIXED 1 15 TEMP. GLASS k ;2 -0 x 4 -Opp SKYLIGHT •1 8 x. it : _ .t ... - «•,+..' Ap? 2' -0" x 2' -0" 2 oil M SKYLIGHT 8 ' OPTION IV, TABLE 6.1, CH. 6 WSEC TOTAL = 351 2448 SF LIVING AREA EQUIP. AFUE =0.78 = 14.33 % GLAZING STEEL #4 BAR wgLL HT. VERT. HORIZ. �_ 18" O.C. 18" O.C. 3 ' 4' •� 10" O.C. 6' as 8' * W/ STEEL CORNER OVERLAP DRIVEWAY PER SITE PLAN <�x x N ; l9 1 , 7. 1 2 4 BARS CONTIN. T &B. Footing/Slab 1 5 �: 3/4 = 1' �s c 1 !'UST 4 PER PLAN r 5,32' SHEATHNG 0 +14" FELT P.T_ 2x6 �-- COW f:OOT. W PER PLAN Wall, T 4 3W ` 1 , UL- LISTED SKYLIGHT 4' -0" MAX. SPAN 0.030 LAMINATED INTERLAYF° FLASHING D 3 T . Skylight Detail _ � Scale. 3/4 ROOF ASSEMBLY PER SECTIAM (3) 16d EA. TRU`. 1" CONT AIRSPACI 2x BLOC w/(2)1Y2 w/#16 ( WIRE ME 26 GA C EDGE FL 5" 'K -LI GUTTER 2x6 FA(Z' O. Eave Typical Scale: 3114• -1 16d ®6 "o.c. 2x JOISTS PER STRUCT. PLANS 8d ®4 "o.c. 2x6 TOP PLATE ---� I X" T &G PLYWOOD %" GWB AT CLG TYPICAL ROOF CONSTRUCTION: CLASS 'B' ROOFING 30# FELT V EXT. PLYWD COMMON TRUSSES ® 24 "o.c. R -38 INSUL. %" GWB 12 41 TYPICAL EXT. WALL CONSTRUCTION: 1 " WOOD SIDING 15# FELT h" EXT. PLYWD 2x6 STUDS ® 24"o.c. R -21 INSUL. )�" GWB TYPICAL INTERIOR WALL CONSTRUCTION: 2x4 STUDS 0 24" O.C)Z" G.W.B. EA. SIDE - TYPICAL FLOOR CONSTRUCTION: 3 / 4 " T &G PLYWD JOISTS PER PLAN R -30 INSUL AT CRAWLSPACE BLW %" GWB ABV HEATED SPACE I Y t I 1 t '1 t '1 1 Y f ` Y `! R -21 1 :14��:4.�'Ll CONTINUOUS RIDGE VENT R -38 i D f r X S� �N� . IF7 z , •{ • 2 A3 0 10101 .0f R -21 ° � I II I I � EXIST/FIN GRADE --I 2x6 P.T. PLATE (ASSUMES NO SURCHARGE) % "Ox 10" AB 0 4' Cox., \ PLATE EMBED 7' MIN w 26 GA. G. 1. � w/ PLATE PER SPECS #16.1 FLASHING � .;�� -' T&G PLYWD w/ R - 30 MIRADRAIN OVER UNHEATED SPACES 140 NSL Z I �� t FI NISH GRADE 12" NA TIVE SOIL (2) 14 TOP CONTIN. 4'0 DS I i I 6 - TIGHTL!NE Ji - • TYP 18 VA MIN. - CL�AN I �` _- - - HORIZ. REINF. AS ►- .Q - .� - PER TABLE � , Q v FREE - DRAJNING �, - ` MATERIAL - VERT_ REINF. AS CC DAMPP'RCK FING _ IPE.R TABLE 4 ' i -' EYWAY �0N�T PERT r-; rr FOOTING DRAik W 16" OF � � � � " ao tlNOtST't1R8E0 SOIL EXAVATED I 0 4 5• 1 s' r 2 4 BARS - l F S+CaI� 3W =1'4r 3'ANT } I A t A f ( 1 l t 1 i 1 I 1 I -- T w ill— R -30 I 1 t t f -' I 1 - _• IT i I� I I ► }� — ill � �ll — „���il �= �— . iI }— '� ► = il; � � =i�l= I! 'lil }I`— — } } — 11 = =11' -- I CRAWLSPACE 18” CL.R. MIN. BETWEEN GROUND AND LOWEST FRAMING MEMBER, Building Section B-B - 1p Scale: 1140 =1' -0w COIDF- C Mv ' 6000 n pt Io Kv r i ia ON � 12 4F I s cc QWTV �-�~ '_,I_'t i a ov c Coto vow DcV / FIN_ (;R. r I I PGs -iii 4 r 1 10 ti ' S -: iol -. ? • w.3 ti Y T . ".rs \ L k' I Go i r 0 �j O .4.0 0) Cf) s > ce Us w U � CD L0 m N N =3 r � V, ;b�lm , Daw 060106 Adlimmm C:x ..r. �� .S. - �•'��• � '_.�_..- -.'..'...'� . _ r.-.� ._.ter.. +.. - +.•!.....�...•• 7t.• M. � . ..�_ _ .__.' .• ��.�..'.._ _ � � w. - v _ may .. - _. -�.�.- ._ ! - ' - s. ....I. �J►�. _.+ ��.. _ _ - OTE: PLATE WASHERS @ ALL ANCHOR BOLTS SHALL BE 1444VIV THICK AND SHALL BE USED ON EACH BOLT. THERE SHALL BE A MINIMUM OF (2) BOLTS PER PIECE. ANCHOR BOLTS SHALL BE LOCATED NO MORE THAN 12" FROM THE END OF A PIECE OF PLATE OR LESS THAN SEVEN BOLT DIAMETERS. 4" CONC. SLAB ON GRADE -- 7 29 ►. i 1 4'- 5Y 15 , _ 0 3 ! ! 6 "x16" FDN ! i! I I VENTS TYP. ' �I (10) 4 = I LOCATIONS A3 � I I E I � CRAWLSPACE ---^ CRAWLSPACE -= I� I I � CRIPPLE WALL I j I I / AS PER DETAIL I I � F r - -• i , / � I I CRAWLSPAC ► I , � 4/A3 00 ( �' CD 2X10 @ 16 "O.C. 2xi (� .lfi'O.C. ! l 1 ! I I r---2 x 10 0 1 C .C. I •_' I - - I ; --- -- Q }� II 1 8 "X24' i 1A ' _�__ -� _._ -� ' I ACCESS i- -- CRAwLSP E i I 7 ____ ■ � I i i i 2 I I STRINGERS, TYP. f I I 2x10 @ FIF N C 16 "O.. I . i I I I 2 -0 SQxy _ D 0ONC- PAD W/ r I i (2.r #4 W.RS EA" WA Y. T` P. (3,1 (2 i I I `�. -�.. � LOCATIONS o/ a I f it � -- CRAWLSPA E r � CIONC. S;_ AB I I I I i Oti 37W- E W/ 6x6 t 6 1 ' CRUSH II I ._._ -� _....�� ,J I o � u ._ g , J ._ 9 _ 0 4x10 ii I li �I I' =i t W O's @ 1 6"O.C. rk i (2) 2x10 �- (3) 2x12 ! STRINGERS, -.. TYP- - - - - -- - _(2) 2x10 - 2) 2x 10 s UNE OF �• elf 2 , ;, R.F. ABOVE K* F(T V ENT & INSUL - • iZx8 - - - �'...:�.� .4 COL. U%E Cf DECK ABM Fourida�tioN First Floor F Plan �R� lical' -W NORTH i 4x10 e I x ■ o x Io x 2 x 10's @ 16 = I Lr— ' i ' O V_ O x Q . t P 2x 10's 2x 1 O's � @ 16"O.C. @ 15 "0.;, (2' 200 -- (` 1x 10 C-0 ON4 r CR On x 7x ! U x ��' @ 16 C. @1 C'0_C- i 1` I I m J J 3 0 Q m W 0 V) z c� J -Q 1 LK OF FLR 48M SoFw, VIM & WSLIL. ..JL 1 Imom ' Von- - ,�.+..�.�• '-� _•...rye `..w.e- �..�.. _ NORTH j INDICATES STDH 14 (4 PLACES) a INDICATES STDH 14RJ (2 PLACES) INDICATES MST 48 STRAPS (6 PLACES) Holddown & StrakSchedule ALTERNATE BRACED WALL PANEL AS PER IBC 2308.9.3.1 ® BRACED WALL PANEL AS PER IBC 2308.9.3 METHOD #3 BRACED WALL PANEL AS PER IBC 2308.9.3 METHOD #5 Braced Wall Panel Schedule 01 � 0, . 4x10 COMMON TRUSS @ 24 O.C. O i' � o I ; • � a U i f t SC.SSOR TRUSSES @ 24 .�0�10 410 m J J 0 W . Q m cr w 1 ? =i 2 0 2 0 2 0 2 0 22 � 22 _ SKYL SKYL t c o - — -- - c it y ot - , -SKnT, Cam- / AWP of Reoad = , :Mark Travers AOkectM ;, :Tot 20SIRSIOM fm 208- b,'!?38 '4315 End Pit SWd - :. Soft WA 88171 VA C T'7d!'IICaU Xt t �f'�I t"�i2� t 0 J o C c Q w � o � U N Y N ~` N� r H Dmw J . U �« oafs: 114304 .{. X ;>oST — 2x6 s 4x10 024' - ■_ Alit-711 - I . l: NORTH r r► q _ *1L - — South Elevation Scale: 1/4"=1'-O" C'4 — I u— P N C 16 -C lie Eti Irs'r C-P V) Cer ac - DIRECT VENT OUTLET �I'I . . LA.. 000 il. + 1 2 7.03' SECOND FLO + 1 18-20' ' FIRST FLOOR + 127-03" - ---� SECONbr FLOOR East Elevation Scale: 114w=11-06 LLJ CN I LA- With= -il- C) LAJ C> - I LA- C) L O + AIR mWA Cm W 12 RECENED 4 OMOFTUKMA t JIG 1 0 Mllj- cl� PEAWT CENTER <B> C) C 4" MAX. - I W C j� I{ Ji j: :� i� i� �7 � ' �t � �� �� �; i •i • i li '� I� I' �� , ,• •� �' � 'I + 12 7 03' 1 / SECOND FLOOR >< i � A IL E GRACE FLOCAR 1-- D"ST , j F4W RN GR uw Ak MML P.. tv%A I u i ElevabW SCOW- 1M ~1 *-(r MP nh- GR. 11 1 t " --" 1 16. • - GARAGE - 1p PRO EMST FIN. GR a P- Won SCOW- 11140=11"O its I&MV of Ro r m"d ta .Mark Travers Amhftck MA T* A Foc 20541284M M15 Eft Pig 9WW Co 0 0 C0 CO3 > M 0 C� � CD 04 04 Oran SAILM .ChKind: uff We: o8r2m A5 Is \+I I b-Du EXIST/FIN GRADE Timber (Qnnectors 58.3. Timber connectors called out by letters and numbers shall be "Strong -Tie" by Simpson Company, as specified in their catalog. Equivalent devices by other manufacturers may be substituted, provided they have IC80 approval for equal or greater load capacities. Provide number and size of fasteners as specified by manufacturer. Connectors shall be installed in accordance with the manufacturer's recommendations. Where connector straps connect two members. place one -halt of the nails or bolts in each member All bolts in wood members shall conform to ASTM A307. Provide washers under the heads and nuts of all bolts and lag screws bearing on wood. Unless noted otherwise, all nails shall be common. All shims shall be seasoned and dried and the some grade (minimum) as members connected. All joists shall be connected to flush beams with "U" Series Joist Hangers. QXRsum Wallboard 59. Screw to all studs, top and bottom plates and blocking with 1-1/4" Type N screw, 4" o.c. at lowest floor level and at 7" o.c. at upper floor levels. 5/8" GWB to use 1-1/4" Type N bulge head screw (0 GWB shear walls only). 60. At areas shown to be fire rated wall, use 5/8" type "x" gypsum wallboard and fasten with 6d cooler nails 0 7" o.c. or 1-1/4" Type N bulge head screw stagger joints. Tape all joints. Braced Wall Qnel 61. Building shall be provided with exterior and interior braced wall lines as per SBC 2308.3. Spacing of braced wall lines shall not exceed 35 FT o.c in both longitudinal and tronverse directions each story. Braced wall lines shall be supported by continuous foundation. See braced wall schedule as per Framing Plan. 62. Truss Loads ..... ............................20# DL Uniform per In. ft. 50# LL Uniform per In. ft. (based on 10 +25 psf with trusses 0 2' -0 ". Point loads as noted on truss drawings. Roof Live Load .............................30 psf Floor Live Load ............................40 psf, 30 psf 0 B occ. Stoir and Corridor Live Load ....... 40 psf r Mechanical Units .. ........................Weights furnished by manufacturer Wind. .85 mph Exp. "B" Earthquake ............ ........................Seismic Design D Z =0.3, R =6.5 Allowable Soil Pressure ................. Equivalent Fluid Pressure .............35 pcf �� ENERGY NOTES General 63. All materials, workmanship and construction shall conform to the requirements of the International Building Code and the Washington State Energy Code, lotest edition. Verify all conditions before proceeding with work. Insulat 64. Walls: Insulated with R -21 butt (for 2x6 walls) and R -21 butt (for 2x4 walls) unless noted otherwise. 65. Roof and ceiling: Insulated with R -38 bolt. Provide insulation in ceiling where possible and in 2x12 rafters if vaulted ceiling conditions exist. Maintain a minimum of 2" clear between top of insulation and bottom of sheathing for venting. Venting must occur in each joist space. Where continuous venting is within a joist space by a header (i.e. skylight or at hip -end), provide (2) 1-1/2" venting holes at the top of the rafter at the header to allow for continual through - venting into the next joist space. 66. Floors: Provide R -30 bott insulation over unheated space unless noted otherwise. 67. Slab on grade: Provide extruded rigid closed cell insulation R -10. Insulation to provide thermal break between slab and footing and run from the top of the slob to the bottom of the footing. Insulation may be interrupted for 6" every 2' -0" to aliox for doweling to tie slab and footing together. 68. Vapor Barriers: An approved vapor barrier shall be installed at exterior walls and at all roof decks, below enclosed joist spaces where ceiling finishes are directly installed to joists, and any other wall or ceiling surfaces which receive insulation. This vapor bonier may be a component of the insulation material. Application and installation of insulation and vapor barriers shall comply with State of Washington thermal insulation standards (H.B. 96). TRICAL NOT 69. All electrical materials, workmanship and construction shall conform to the requirements of the International Building Code and the Notional Electrical Code, latest edition. Verify oil conditions before proceeding with work. 70. All electric hot water heaters shall be provided with a shutoff switch close to the tonk. 71. ! Proviae and install smoke detectors in compliance with governing codes. Smoke detector to be 110v w/ battery back -up, interconnected. MECHANICAL. NOTES (Residential only) 72. All mechanical materials, workmanship and construction shall conform to the Intemationai Building Code and International Mechanical Code, Forest edition. Verify all conditions before proceeding with work. 73. Mechanical ventilation systems capable of providing 5 air changes per hour shall be provided in rooms not provided with or, operable window of 1.5 sf or greater per IBC. ?4. Hat waver heaters small be provided wdh pressure reiief valve. K electric. provide shutoff switcn close to tcnk. Insulote in compliance with Washington State Energy Code. All hot water lines shall be fitted with snop - insulation it compliance with Washington State Energy Code. Wro!e house Ventiotion 5 4ge-n ( Residential only) 75. 6 diameter auct from oi;tside to the return cir pienum. Minimum 0.35 air chor -ges per hour, but not less than '5 cubic feet per menite per bearoor pigs on ocditional 15 c.:bic feet pe• minute. maxir'1urn or cho per ho4.r must be limited to 0.5 air charges per hc•u• the systeT rn,ist supply 00side air t:, al hatxtobie roorns thr .ugn the fo-ced a.r reater.g sys'e 7E All: .^e - 4o:,c e s ante - r. z f' 3i to rec s►ty acc essibie Ord be ccPabse zf cperctiir g I ver :►Wt,or stister, •it% -.it energ z ►n ctt-er energy cons.xrwg oop"ances '?1e for c r Syste - r. sna I be w t ri s c,� N: w !t A;° C..cts spa ter r rate ii ts•de t.,e b%.Adiinc Etra.sst d..rcts r systems trot oaerote i'terr'''" tter t -. Sr'3' Ce eti;,_jc*ea w :t i t '* araf-. .- .ar"-4x- rL ea M3 st 0 S-:,ii )' Cucts r scoces sttc «_ tie xs..irtee c. c vr of r? -E =he occ J--VII dcmper sr`[ be : " ,..T ;f a 3r i is vna' be scree-t_ or o*r+e- se protected `ror entry ;y - -L9 is bbd aebr-*_ ono s'%aK be oc. zeta s, ass -oc to ta. a a e f tr, a fo&oww --; oreas C. os trap- T ;, feet 4 woer on cPPbOrt`e vent 0- -Xiet. ;suss s.r: h vent is 3 feet above ire c.Asoc* :Pr me, inhere t w c*:i uv .:d ee-ztmxmtwe c4cps. furies.. or f -wron ave vapows A ftaxarrxua cr ins.+• t7v lecot•ar rZiOrr Cr SgKXe NNW4 4 tv - 16116--b4:rr" 0P;* - *Zes Ittere+r. Ckner tipar- t o feet firM a •TrA ape -big of a FkAnbWas �31`o•'o9e Swell. es+10ess tide VW4 eoenwlg s at ~east s feet the or =+yret. '*e cuts+ae air connectxorm to the r+eturr or Stearn SW tie krcated to prlvwt sf+eac0 x time hex evchargLw Miscellaneous Steel 49. Structural steel shall be RISC- LRFD, RISC 335, AISC -HSS, Fy= 36,000 psi. All welding shall conform to the AWS codes for arc and gas welding in building construction. All welds shall be 3/16" minimum unless otherwise noted. Welding electrodes shall be E70XX electrodes for manual shielded metal -arc welding or equal electrode for their welding processes. Welded points shall conform to AWS pre qualified joint details for welded construction. All welding shall be performed by AWS certified welders. Miscellaneous hangers to be Simpson or approved equal. All hangers to be fastened to wood with proper nails. All holes shall be nailed. All nails shall be common wire nails. Machine bolts to be A -307 Anchor bolts shall be stainless steel 5/8" diameter at 2' -0" o.c. embedded 8 ". There shall be a minimum of 2 bolts per each piece with one bolt located within 12" of each end and within 12" of each corner, unless otherwise noted. Provide standard plate washers under all bolt heads and nuts bearing on wood. 50. Lumber (unless noted otherwise) Joists ani Rafters (incl. 2x6 Hem - Fir No. 2 and larger members used minimum basic design stress as studs and plates) fb= 900 psi Beams and StrinQgrs Douglas Fir No. 1 minimum basic design stress fb= 1350 psi Posts and Ti mber s Douglas Fir No. 1 minimum basic design stress f'c= 1000 psi Sleds. Plates and Misc. Hem -Fir construction grade Ughl Fro Glue Laming ed Timber 24F -V3 fb =2400 psi All other lumber Hem - Fir standard or better 51. All framing to comply with IBC Chapter 23. Nail size and spacing to conform to IBC Section 23 and table 2304.9.1. All timber to be kiln dried. All grades shall conform to "WWPA Grading Rules for Western Lumber ", most recent edition. Bolt heads and nuts bearing on wood shall be provided with standard cut washers. All wood in contact with concrete shall be pressure treated or protected from decay. All nailing not noted on drawings shall conform to IBC Table 2304.9.1. See miscellaneous steel for hangers. At sawn timber joist areas: Provide cross- bridging and solid blocking at bearing points as per IBC 2306.5.1.2. Provide double joists under oil partitions. Provide double joists each side of openings unless detailed otherwise. Provide solid blocking over bearing partitions, walls and beams. Attach timber joists to flush headers and beams with Simpson series metal joist honger to suit the joist size. Plywood 52. Plywood panels shall meet the requirements of the latest edition of "U.S. Product Standard DOC PS -20 for Softwood Plywood ". Each piece shall bear the APA grade trademark of the American Plywood Association. Plywood roof and wall sheathing in accordance with SBC Section 2304. Minimum plywood to be 6" o.c. at all supported edges and 12" o.c. at interior supports. Nails to be 8d common for 1/2" plywood, 10d common for 5/8" and 3/4" plywood roof and floor sheathing. Stagger and lop at roof and floor sheathing. Nails shall be driven flush but not fracture the surface of the sheathing. All floor sheathing to be glued and nailed continuously at all floor joists. Span rating shall be 40/20 in X floor sheathing and 20/0 in X" roof /wall sheathing. 53. At shear walls: Nails sholl be 10d common for 1/2" sheathing with all edges blocked, 10d nails 0 4" o.c. 0 edges and 10" o.c. 0 field. 54. Support shall be supplied to oil plywood edges with plyclips, blocking, tongue and groove plywood joints or other approved methods per APA recommendation. Supports to occur at 4" o.c. 0 edges and 6" at field. Glued Laminated Members 55. Glued laminated members shall be fabricated in conformance with U.S. product standard as required in AITC A190.1 and ASTM D3737 for structural glued laminated timber. All members shall be fabricated of industrial grade western woods in accordance with American Institute of Timber Construction (AITC) Specifications using water resistant glue throughout. Each member shall bear on AITC identification mark and be accompanied by an AITC certificate of conformance. One coat of end sealer sholl be applied immediately after trimming in either shop or field. Laminated Veneer Lumber CLVL) 55.1 Laminated veneer lumber shall be manufactured under a process approved by the National Research Board. Each piece shall bear a stamp or stamps noting the name and plant manufacturer, the grade, the Notional Research Board number, and the quality control agency. AJI laminated veneer lumber shall be manufactured in accordance with NER -126 using Douglas Fir veneer glued with a waterproof adhesive meeting the requirements of ASTM D2559 with all grain parallel with the length of the member. iFb = 2600 PSI, E = 1,800,000, Fv = 285 (for 1.8E members) ,Design shown on plans is based on lumber manufactured by the Trus -Joist Corporation. Alternate manufacturers may be used subject to review and approval by the architect and structural engineer. Alternate joist hangers and other hardware may be substituted for items shown provided they have I.C.B.O. approval for equal or greater load capacities. All joist hangers and other hardware sholl be compatible in size with members provided. Porollel Strand Lumber (Ef�,) 55.2 Parallel strand lumber shall be manufactured under a process approved by the National Research Board. Each piece shall bear a stamp or stamps noting the name and plant manufacturer, the grade, the National Research Board number, and the quality control agency. All parallel strand lumber shall be manufactured in accordance with NER -292 glued with a waterproof adhesive meeting the requirements of ASTM D2559 with all grain parallel with the length of the member. Fb = 2900 PSI. E = 2.000.000. Fv = 290 (for 2.OE members) Design shown on plans its based on iusnber manufactured by the Trus -Joist Corporation. Alternate manufoctrers may be used subject to review and approval by the architect and structural engineer. Alternate joist hangers and other hardware nay be substituted for items shown provided they have I.C.B.C. approval for equal or greo;er Iood capacities. All ,joist hangers and other hardware shoo be compatible in size with members provided. Roo Trusses 56. Trusses to be designed ty c licensed Washiingten State Professional Engineer. Roof teases shall oe pia,nt fabricated of Douglas Fir - .orcti or Hens F ir - Am rr^echor g_ come, tors shcN be 1BC approved and boas shad, be in acc ordar c e wrtn the elbwar ie stresses of Liss cornecto - for oopro rol and verify at truss lengths proof to fate cation Shop drawings shch incijave a peocing ;,Ioni road dbgroms and erection brocirg and tarrddirl req..xrei ents. Each wood to member shOrl carry c gr"ng stomp N. f eld r todifec=aons of trusses w:1 be Mowed w:tro -.R the mcn,,foct.rer's ; pprova (3) sets s hop Cower •gs reau.r ed. S%A>mit shop Cogs as regwred by local o.&►orrty Focf cr_ - =- •OvmK1e orj: r.,Jpus �.Y 'ny f raf:er5 ,:t .he si opoo'. S and craw or<q r-9 reQwr/C P de t40Ck- - arw-* trOA?n - or t ^..sses per roof t T<r.0 -' C1,0e- req: r+ .ts Flush beo s nct - aut r the p• ,- es s Ce oa4:�e ms's AM vert•ca-y a- r4r%cted beams 3r:d neoder s shy to spied tcgett"er w th 2 - as s of 16C no.rs O ! o c stoggered Rafter onz t-.zs ccrectcvs s t%e F1 xc Jrdont e ••' &C TJp►e X304 9 1 figm_Eam". 2v 4 st-.,cs unless voted ottlerw+®e W NO less Vw (3 t studs shill be ionstaiiiiec a:t eo& _o rkr 3n an extercr 00 r AN 01a and m 1dow heoda 'sot c o fed out or the pion shat De 1 \ N 1, D Z •, �/) #2 with srr! : rVp* cnd one stun eo& end fcr ocenw ap 4 - -0 Of 4ss aid two c* ou^�rs ani cc st,.rd for c4pv rlg ffwe Van. 4'-C" wide per 0l. C?- per 23 Ali eokorn s rbot CoSec or.A or► the o�sr1s shit* be k a". 1 stalls. Spike be*WX*ed Cvwrrrs t0grt W with t 6d naliq 0 16' o : 1111111 1% !M wcod des and thoc*w%S wt dot zcetact einilip ��or*cne�te s►noil be pressili" treat or p mtectod f:'+ decap The SQW_ •W%V and spocan of stubs OWN t* in arccoicaorlce woth `0C 2300 9 1 DOORS. WINDOWS AND QLAZIN 27. Glazing in compliance with IRC Section 308 and Washington State Safety Gloss Law. Exceptions ore as outlined in IRC R308.4. 28. Glazing in locations subject to human impact such as glass on doors, glazing within 12" on either side of a door opening, glazing closer than 18" to o floor, shower door and tub enclosures shall be wire reinforced, tempered gloss, laminated safety glass or shatter resistant plastic. 29. Sliding and bifold glass doors to be safety glazing laminated as per IRC R308.6.2 or tempered glass. 30. Shower enclosures shall be approved wire reinforced, tempered or laminated safety glass or shatter resistant plastic. 31. Glazing within 18" of floor and greater than 18" in least dimension shall comply with impact loads per IRC Section R308 3. 32. All exterior wall glazing shall comply with Washington State Energy Code (WSEC). 33. Egress in every sleeping room shall hove a min. net clear opening of 5.7 SF. The min. net clear opening height dimension shall be 24 ", and min. net clear opening width dimension of 20 ". Finished sill height to be not more than 44" above finished floor per IRC R310.1. FIREPLACES 34. Fireplace code per IRC Chapter 10, local Building Deportment and requirements of manufacturer. See further notes on fireplace section. 35. Masonry fireplaces and chimneys are to be constructed to conform to all applicable portions of the IRC and Municipal Codes. Flue liner shall be install as oer IRC R1001-9. Flue area per IRC R1001-12. Chimneys shall support only their own weight unless specifically designed to support additionol loads. 36. All fireplaces ore to be provided with tightly fitting flue dampers, operated with a readily- occessible manual or approved automatic control and an outside source of combustion air, min. duct size of 6 sq. inches in area, provided with readily operable damper, located in front part of firebox. Fireplaces must be installed per any iRC and local conditions of approval. See fireplace details IRC FIG 1003.1. 37. Prefabricated fireplaces, chimneys and related components to bear U.L. 127 of approval. 38. Hearth Extensions. Heorths shall extend at least 16" in front of, and at least 8" beyond each side of the fireplace opening. Where the fireplace opening is 6SF or larger, the hearth extension shall extend at least 20" in front of, and at least 12" beyond each side of the fireplace opening. 39. Provide 2" clear between masonry and framing members at fireplaces. 40. Provide chimney reinforcement and anchoring per IRC 1001.1. TRUCTURAL NOT General 41. All materials, workmanship and construction shall conform to the requirements of the International Building Code, latest edition. Verify all dimensions and condition before proceeding. Provide erection bracing as necessary until permanent support and stiffening are installed. Qemolition 41.1 Contractor shall verify all existing conditions before commencing any demolition. shoring shall be installed to support existing construction as required and in a manner suitable to the work sequences. Demolition debris shall not be allowed to damage or overload the existing structure. Limit construction loading (including demolition debris) on axisting floor systems to 40 psf. 52 Al2 Soils Report# dated 42. Unless a soils investigation report by a qualified soils engineer is provided and attached, foundation design is based upon a minimum average soil bearing of 2,000 psf. All footings shall be cost on undisturbed firm natural soil or compacted soil of 2,000 psf bearing capacity at least 1'-6* below lowest adjacent grade, free of organic materials. Footing excavation shall be free of loose soils, debris and free of water at all times. on r t 43. The selection of materials for, and the mixing and placing of all concrete, shall conform to the requirements of the Seattle Building Code, latest edition. Materials shall be proportioned to produce a dense, workable mix, having a maximum slump of 4 inches which can be placed without segregation or excess -free surface water. Water- cement ratios for 2500 PSI concrete strength (F'c) shall be a maximum of 6 gallons of water / sock of cement. The minimum number of sacks of cement per cubic yard shall be 16.0. 44. A water reducing admixture, conforming to ASTM C494 Classification D, shall be used in strict accordance with the manufacturer's recommendations. An air entraining agent, conforming to ASTM C260, shall be used in oil concrete mixes. The amount of entrained air shall be 4.5% plus or minus 1.5% by volume. Maximum area of slab before control or expansion joint: 200 sf. G ro u t 45. Grout shoN be Masterflow 713, or acceptable substitute. masOrrY 46- Masonry bearing and shear wags to be reinforced and design in occordance w/ Section 2106.1.1. Units to be load bearing grade. Dn type - s" mortar shall be used. Al- masonry reinforcing requirements shall conform to !BC Chapter 11. Girl rcin 47 Unless noted otherwise, all reinforcing steel snail be deformed bars in accordance with either the AISC LRFD. AlSC 335 or RISC -HSS. Welled w +re fobrc shoN conform to IIK 2204 1- J1lininx.m reinforcing in concrete slabs on grade and sidewalks shcdi be 6a6 - WI 4 x W1.4 WWF. Lop one Ful0l mesh at splices. Reinforcing steel snag be securely t t : in piece with J16 oaible anrteofed iron wire_ Bars shall be de :oiled in oc = ordonce lxetr the - ACI Manuod of Standard Proc ice for Detcding Reerforced Concrete Structures - . krest eoit�on. A minimum lap for adl bars shall be 1' -6 or 30 bar diameters. whiche% m rro�e The designed ord d tc3ed to resist Seismic Forces seal° to in occordorce w/ 34!. par; I or W. K *hFOKCING STEE_ IRCTEC - ION GENERAL NOTES The following notes apply except where shown otherwise. MISCELLANEOUS 1 . These drawings ore the exclusive property of the Architect and may be reproduced only with the written permission of the Architect. Authorized reproductions must bear the name of the Architect. 2. All construction shall conform to the 2003 International Residential Code (IRC), also in accordance with the Washington State Laws and Regulations and various codes imposed by local authorities. This project must also comply with 2001 WSEC. 3. Do not scale these drawings for critical dimensions. Contractor to verify all dimensions and datums before commencing work and be responsible for their accuracy. Dimensions shown are typically to the face of framing stud, unless noted otherwise. 4. Vent dryer, bath fons, ranges /ovens, and fireplaces to the outside. 5. Vertical shafts (dumbwaiter, laundry chute, etc.) shall be lined with 5/8" Type "X" GWB or 24 go. sheet metal. FOUNDATION 6. Footings and foundations shall be provided as shown on the drawings. Unless otherwise specifically provided shall conform to the requirements of the IBC. Footings shall extend below the frost line. 7. Foundations supporting wood shall extend a minimum of 6" above adjacent finish grade per IBC. 8. Foundations where the surface is sloped more than (1) foot in (10) feet shall be level or shall be stepped so that both top and bottom of such foundation are level per IBC Section 1805.3. 9. Pier footings under bearing walls of post and beam systems and concentrated loads shall have a minimum of 10" edge thickness and shall project a minimum of 8" above exposed earth per IBC Section 1808.2.8. 10. Where structural columns and posts ore exposed to weather or water splash above a concrete surface, provide a 1 " plinth above the concrete surface per IBC Section 1807. 11. Provide 14" minimum crawl space under wood joists and 12" minimum crawl space under wood girders per IBC Section 2308.2- exception.. 12. Provide electrical ground wire embedded in foundation per electrical code. 13. Foundation plates shall be bolted to the foundation with no less than 5/8" nominal diameter steel bolts embedded at least 8" into the concrete and spaced no less than 24" apart. There shall be a minimum of (2) bolts per piece and within 12" from each end, unless otherwise noted. 14. A ground cover vapor barrier of min. 6 mil (0.006 ") polyethylene (or equivalent) shall be installed in all crawl spaces, joints lopped 12 Extend up foundation wall at least to outside ground line. 15. Crawl space ventilation minimum net area not less than (1) SF for each (1 SF. Openings shall be pia-ed as close to the corners as practicable and shall provide cross ventilation on at leas two approximately opposite sides per IBC Section 1203.3. 16. Unobstructed w cess to crawl space to be min. 18" x 24' r I ti 1209.1. 3 "x "x 16.1. Plate washers at all anchor bolts shall be stainless steel thick and shall be used on eac-i bolt. There shall be a minimum of (2) bolts per piece. Anchor bolts shall be located no more than 12" from the end of a piece of plate or less than seven bolt diameters. 16.2 Epoxy- grouted items specified on the drawings shall be grouted with epoxy -tie adhesive by Simpson Strong -Tie Company. Install in strict accordance with manufacturer's recommendations. Special inspection of installation is required. ffi 6MIN 17. All framing shall be provided as shown on the drawings. Unless otherwise specifically provided, framing shall conform to the requirements of the IBC. 18. Foundation cripple walls shall be framed of studs not less in size than the studding - above with the minimum (wall height) length of 14', or shall be framed of solid bloc Where exceeding 4' -0" in height, such walls shall be framed of studs having the side required for an additional story per IBC Section 2308.9.��+ 19. Fire and draftstops shall be installed to cut off enclosed openings, both horizontal and vertical, between all floors, attics, etc., and shall conform to the 4 Z�QS requirements of IBC Section 717.4 (attics) and 717.3 (floor). S� 20. All exterior walls and main cross stud partitions shall be effectively and thoro t braced per IBC Section 2320.9.3. u9 Tt�kVi1 .. n� 21. Rafter ties maximum 4 -0 o.c. where ceiling joist and rafters ore not poroiliel, fasten as required per IBC Section 2308.10.1. Connections sr►oN be in accordance w/ the Table 2308.10.4.1 and 2304.9.1 22. Goroge and house occupancy separation min. 1 hr taped and finished per IRC R705.5.1. 45 min - door required in 1 hour wail (1 - 3/8' solid core with closer) Garage with habitable space above requires OH beonng supports to be 1 nour rated. 23. Tub surround shall oe a 6' - above finished floor with water resistant backing. 24. 'Stair Notes: Menerwrrt head room E' -8 - . min- tread 10 - . rrox riser 7 hoodroil min_ ?4" a 1d max. 38' above star nesmg, hon.lro:1 to be , -1;'2 cross section and men 1/2' away from wall Mondrai- ends shOii oe returned a - shall termenate ir. nail posts ,r safety terr►wrxft. tnstrA fire b- ock -,g at rrd s;'%.n ger span o -4 at wall cl�nq fi st -.r_ C, Cove wogs o rW sotSts rf isatge space under storyr w►tn - " ; ,I ' E; - type x - GMB See IRC i .5 i 2`- Att:. veb'vtior ' , ` 150 SF x tt ac oree cr 1/ 30C :f 1/d is r soK4 aril 1/? is 3"r== '+.t�' " • -3o plate " per PC :;S: t Prowde holes r frorr a-q nx noers .%f rafters and tecders c.'o.ssd .opeonigs in -afters `,c - ft+ for contnuc-is ventng sc ro r'a`t spoce conta rson -v ftc Y 26 - Att access : 22 3J w- min '?0 4N0bstrutted reax2rocm, reodety xcess.�e Q.oening oer W_ R8G - s :6.1 AM t'rWTWV 11110M sere eft - _ *r4aCt with press tr korber :o be stemless steel ,ra101111Aflta : S> M of P4=d .. ; r . Y Mark Travers : Tit 20670386 " -F /MM/_ 208 - .. 380k WA OM : USE PROTECT)GtA `^ arbc spas burs - inte+rw foces 3 ;'4 V_ 5-x aria wag bars - evp••td to 2 (f o and aoovee) weather ants/ or ecrth 1- : ; 2 ( #`_ znd ssnoier� 611iia as. caner steel bars tc r wtc*+ 'worcar" reinforcer -K" V*oere a concrete soN el"d does not ntersiec t ora other spar, hook hocetz Mall bons 90r a1d prcv*ft a 6 bar 6 meter evtomm r . At co w+ai3 lap vwticar stee+ 42 bor d ar.",eters waft footing darnels tcr'ecm a •aos s bas be rew*onced as shown on ttv pions Grid detoft and it nct stmmn snarl dye 04 0 16` a c each way at the Cep *V fore of a 6 waJ and #4 0 1 2" a c eoctt '" at the center vv of an a wag C GENERAL NOTES The following notes apply except where shown otherwise. MISCELLANEOUS 1 . These drawings ore the exclusive property of the Architect and may be reproduced only with the written permission of the Architect. Authorized reproductions must bear the name of the Architect. 2. All construction shall conform to the 2003 International Residential Code (IRC), also in accordance with the Washington State Laws and Regulations and various codes imposed by local authorities. This project must also comply with 2001 WSEC. 3. Do not scale these drawings for critical dimensions. Contractor to verify all dimensions and datums before commencing work and be responsible for their accuracy. Dimensions shown are typically to the face of framing stud, unless noted otherwise. 4. Vent dryer, bath fons, ranges /ovens, and fireplaces to the outside. 5. Vertical shafts (dumbwaiter, laundry chute, etc.) shall be lined with 5/8" Type "X" GWB or 24 go. sheet metal. FOUNDATION 6. Footings and foundations shall be provided as shown on the drawings. Unless otherwise specifically provided shall conform to the requirements of the IBC. Footings shall extend below the frost line. 7. Foundations supporting wood shall extend a minimum of 6" above adjacent finish grade per IBC. 8. Foundations where the surface is sloped more than (1) foot in (10) feet shall be level or shall be stepped so that both top and bottom of such foundation are level per IBC Section 1805.3. 9. Pier footings under bearing walls of post and beam systems and concentrated loads shall have a minimum of 10" edge thickness and shall project a minimum of 8" above exposed earth per IBC Section 1808.2.8. 10. Where structural columns and posts ore exposed to weather or water splash above a concrete surface, provide a 1 " plinth above the concrete surface per IBC Section 1807. 11. Provide 14" minimum crawl space under wood joists and 12" minimum crawl space under wood girders per IBC Section 2308.2- exception.. 12. Provide electrical ground wire embedded in foundation per electrical code. 13. Foundation plates shall be bolted to the foundation with no less than 5/8" nominal diameter steel bolts embedded at least 8" into the concrete and spaced no less than 24" apart. There shall be a minimum of (2) bolts per piece and within 12" from each end, unless otherwise noted. 14. A ground cover vapor barrier of min. 6 mil (0.006 ") polyethylene (or equivalent) shall be installed in all crawl spaces, joints lopped 12 Extend up foundation wall at least to outside ground line. 15. Crawl space ventilation minimum net area not less than (1) SF for each (1 SF. Openings shall be pia-ed as close to the corners as practicable and shall provide cross ventilation on at leas two approximately opposite sides per IBC Section 1203.3. 16. Unobstructed w cess to crawl space to be min. 18" x 24' r I ti 1209.1. 3 "x "x 16.1. Plate washers at all anchor bolts shall be stainless steel thick and shall be used on eac-i bolt. There shall be a minimum of (2) bolts per piece. Anchor bolts shall be located no more than 12" from the end of a piece of plate or less than seven bolt diameters. 16.2 Epoxy- grouted items specified on the drawings shall be grouted with epoxy -tie adhesive by Simpson Strong -Tie Company. Install in strict accordance with manufacturer's recommendations. Special inspection of installation is required. ffi 6MIN 17. All framing shall be provided as shown on the drawings. Unless otherwise specifically provided, framing shall conform to the requirements of the IBC. 18. Foundation cripple walls shall be framed of studs not less in size than the studding - above with the minimum (wall height) length of 14', or shall be framed of solid bloc Where exceeding 4' -0" in height, such walls shall be framed of studs having the side required for an additional story per IBC Section 2308.9.��+ 19. Fire and draftstops shall be installed to cut off enclosed openings, both horizontal and vertical, between all floors, attics, etc., and shall conform to the 4 Z�QS requirements of IBC Section 717.4 (attics) and 717.3 (floor). S� 20. All exterior walls and main cross stud partitions shall be effectively and thoro t braced per IBC Section 2320.9.3. u9 Tt�kVi1 .. n� 21. Rafter ties maximum 4 -0 o.c. where ceiling joist and rafters ore not poroiliel, fasten as required per IBC Section 2308.10.1. Connections sr►oN be in accordance w/ the Table 2308.10.4.1 and 2304.9.1 22. Goroge and house occupancy separation min. 1 hr taped and finished per IRC R705.5.1. 45 min - door required in 1 hour wail (1 - 3/8' solid core with closer) Garage with habitable space above requires OH beonng supports to be 1 nour rated. 23. Tub surround shall oe a 6' - above finished floor with water resistant backing. 24. 'Stair Notes: Menerwrrt head room E' -8 - . min- tread 10 - . rrox riser 7 hoodroil min_ ?4" a 1d max. 38' above star nesmg, hon.lro:1 to be , -1;'2 cross section and men 1/2' away from wall Mondrai- ends shOii oe returned a - shall termenate ir. nail posts ,r safety terr►wrxft. tnstrA fire b- ock -,g at rrd s;'%.n ger span o -4 at wall cl�nq fi st -.r_ C, Cove wogs o rW sotSts rf isatge space under storyr w►tn - " ; ,I ' E; - type x - GMB See IRC i .5 i 2`- Att:. veb'vtior ' , ` 150 SF x tt ac oree cr 1/ 30C :f 1/d is r soK4 aril 1/? is 3"r== '+.t�' " • -3o plate " per PC :;S: t Prowde holes r frorr a-q nx noers .%f rafters and tecders c.'o.ssd .opeonigs in -afters `,c - ft+ for contnuc-is ventng sc ro r'a`t spoce conta rson -v ftc Y 26 - Att access : 22 3J w- min '?0 4N0bstrutted reax2rocm, reodety xcess.�e Q.oening oer W_ R8G - s :6.1 AM t'rWTWV 11110M sere eft - _ *r4aCt with press tr korber :o be stemless steel ,ra101111Aflta : S> M of P4=d .. ; r . Y Mark Travers : Tit 20670386 " -F /MM/_ 208 - .. 380k WA OM : Omm JtOFSF MTT DOW 25MA5 ---- - - - - -- ---- ---- - --- �- � I SPECS ~ r • q 0 V_ I I U) m ..� 4-0 Co Alma n � Cl) L V C 0 C4 Omm JtOFSF MTT DOW 25MA5 ---- - - - - -- ---- ---- - --- �- � I SPECS ~ r • q