Loading...
HomeMy WebLinkAboutPermit D05-147 - PUGET SOUND BLOOD CENTER - HOMESTREET BANK - TENANT IMPROVEMENTHOMESTREET BANK 130 ANDOVER PK E DOS -147 W. Q W5 U O; N 0 W = J � .W O u_ a' �w z H O: z I: ut w ' N: '0 W W` O; tllZ p O z C ity a'1 Tukwila Steven M. Mullet, Mayor Department of Community Development 6300 Southeenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: cOuhwila.wa.us DEVELOPMENT PERMIT Parcel No.: 0223100040 Address: 130 ANDOVER PK E TUKW Suite No: Permit Number: Issue Date: Permit Expires On: Steve Lancaster, Director DOS -147 06/06/2005 12/03/2005 Tenant: Name: HOMESTREET BANK Address: 130 ANDOVER PK E, TUKWILA WA t r Owner: Name: PUGET SOUND BLOOD CENTER Phone: s. Address: DIRECTOR OF ADMINISTRATION, 921 TERRY AVENUE ` Contact Person: Name: GLEN E. KANZELMEYER ! Address: 2000 TWO UNION SQUARE, 601 UNION ST t, Contractor: i Name: RAFN COMPANY Address: 1721 132ND AVE NE, BELLEVUE WA Contractor License No: RAFNC* *06137 Phone: 206 389 -4415 Phone: Expiration Date: 04/20/2006 DESCRIPTION OF WORK: DEMOLISH SEVERAL EXISTING WALLS TO CREATE OPEN OFFICE AREA, CONSTRUCT NEW WALLS TO FORM WORK ROOM. NEW FINISHES (PAINT, CARPET, SHEET VINYL, RUBBER BASE AND ACOUSTIC CEILING TILES) AND OFFICE FURNITURE SYSTEM. REPLACE ALL EXISTING LIGHT FIXTURES AND NEW POWER AND DATA UNDER SEPARATE PERMIT. Value of Construction: $25,000.00 Fees Collected: $804.72 Type of Fire Protection: AUTO FIRE ALARM International Building Code Edition: 2003 Type of Construction: Occupancy per IBC: 0008 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: N Hauling: N Start Time: End Time: Land Altering: N Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: N Moving Oversize Load: N Start Time: End Time: Sanitary Side Sewer: N Sewer Main Extension: N Private: Public: Storm Drainage: N Street Use: N Profit: N Non - Profit: N Water Main Extension: N Private: Public: doc: IBC - Permit D05 -147 Printed: 06 -06 -2005 i n�. �:. i _ ..tli: ..qY. I'FI w3 a!6' tt:4.4.r ' #74. �X � ��W4.•a +RNhM�� ��Nh7 . � `t'�un..ar'1.+..... ., .. .. - t V'r5 +�+'� 3A'R• . i+F{Y'4' k S�M'�M Mfi1. tM..iHt+�nWa <:wd.'AV.", ^.;:: • oW:tiriolatr^iw� Z Z W 2 D 10 UO CO) e U) =. CO) LL W 0. U. co) d =w Z� w o: w �o U CO) W O Z' O Z i N., ' O 1908 City a. , Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: ci.tukwila.wa.us . I Water Meter: N I 1 t * *continued on next page ** Steven M. Mullet, Mayor Steve Lancaster, Director i doc: IBC- Permit D05 -147 Printed: 06 -06 -2005 i City 6K Tukwila ` Steven M. Mullet, Mayor Departn:eitt of Commuttity Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: cOukwilama.its Permit Number: Issue Date: Permit Expires On: Steve Lancaster, Director D05 -147 06/06/2005 12/03/2005 Permit Center Authorized Signature: e- Date: 0� ��!°�OS I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permi presa a to give authority to violate or cancel the provisions of any other state or local laws regulating construction r the'performa ` of work. I am authorized to sign and obtain this development permit. Signature: Date: '6 o 1 Print Name: . P/- This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. It D05 -147 Printed: 06 -06 -2005 Z J- W It � W D. J U 00 1 cn W W= J if— Cc LL ; 111 0 u- Q = Cl. iF- _, Z �. 0. Z F— 25 D0 :0 W LJ .H U LL — 0 Z. U Z �.. g City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 PERMIT CONDITIONS Parcel No.: 0223100040 Address: 130 ANDOVER PK E TUKW Suite No: Tenant: HOMESTREET BANK Permit Number: Status: Applied Date: Issue Date: DOS -147 ISSUED 05/04/2005 06/06/2005 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design requirements of ASCE 7. 6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. 7: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 8: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Department of Public Health - Seattle and King County (206/296- 4932). 10: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department of Labor and Industries (206/248- 6630). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: ** *FIRE DEPARTMENT CONDITIONS * ** 13: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 14: The total number of fire extinguishers required for a light hazard occupancy with Class A Ore hazards is calculated at doc: Conditions D05 -147 Printed: 06 -06 -2005 :.c:lt�.S...n�. �:; i,1...i .��,::1.,: ... i. i✓: m, is .Hx:ii�iae°,'�.3^,..lis¢++i+�ii »443f�"'�t�R/Yi tA1i� z Z 2 0 N w= F- �U_ W� � U) D = �W Z E- ►- O Z f_ w LIJ � o U ON D H WW LL O. Z. U O Z Cit y of Tukwila f9C8 Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) Q 15: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or = z brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so 0 0 that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross Co o weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the J = floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 CO inches (102 mm). (IFC 906.7 and IFC 906.9) w O 16: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) Q U. Nd 17: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available t=- s f for use. These locations shall be along normal paths of travel, unless the fire code official determines that the ? i— hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) z O 18: ** *MEANS OF EGRESS * ** - IFC Chapter 10 UJ w 2 o 19: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. U p (IFC 1008.1.8.3 subsection 2.2) = W 20: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle U- p i is engaged from inside the tenant space. (IFC Chapter 10) Z U= 21: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) F- Z 22: Means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. The means of egress illumination level shall not be less than 1 foot - candle (11 lux) at the floor level. The power supply for the means of egress illumination shall normally be provided by the premise's electrical supply. In event of a power failure an emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 23: ** *FIRE ALARM SYSTEMS * ** - City Ordinance #1900 - NFPA 72 24: Maintain automatic fire detector coverage per N.F.P.A. 72. Addition /relocation of walls, closets or partitions may require relocating and /or adding automatic fire detectors. 25: Maintain fire alarm system audible /visual notification. Addition/ relocation of walls or partitions may require relocation and /or addition of audible /visual notification devices. (City Ordinance #2051) 26: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 27: Call the Tukwila Fire Department at 206/575 -4407 for approval of any system shut down. Have job site address, name and the Tukwila Fire Department Job Number available to confirm shut down approval. (City Ordinance #2051) 28: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) doc: Conditions D05 -147 Printed: 06 -06 -2005 x.71,.:+ •uc.�tl...�(: ;i= :5:;a�}ts: :;�ku, �. +: oF�L. 71:,.. 1.. �d -,.fiearX.'eSkM..•.tt.At1^+b 1�� i City of Tukwila f906 Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 i (206) 431 -3670 29: ** *BUILDING CONSTRUCTION * ** - IFC - IBC 30: When walls and ceilings are required to be of fire resistive or noncombustible construction, interior finish materials shall meet the requirements of International Building Code 803. 31: Accumulation of combustible waste material is prohibited during the demolition phase of this project. Remove and properly dispose of all waste material prior to the close of the working day and as often throughout the day as needed. 32: These plans were reviewed by Inspector 510. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. * *continued on next page ** j doe: Conditions D05 -147 Printed: 06 -06 -2005 IN 11 i t z a QQ � J U UO rn ( . U J J � CO) L W O LL ¢, co) d =W z�. O. z �-' U CO: ;O : WW F=- U . H tll z:. U N O z i t City of Tukwila r9ce Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or thg-perforM - N of work. Signature: Print Name: / A" P ✓r Date: � � l ILA,k 1808 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 Building Permit No. Mechanical Permit No. Public Works Permit No. Project No. For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: 02231 C 00 J+ O 1 Site Address: i3 ANlovVE�- fANC- E Suite Number: 1 Floor: 1` Tenant Name: HOAAESTREI:'r 7m k New Tenant: ix ..... Yes ❑ .. No Property Owners Name: PARK C-As l 'O VILV I N & t I0 C Mailing Address: C IO`( S ! 3 Ml STS I , SU111 206 1 = EVEML WAJ VJA lboo3 City State Zip CONTACT PERSON Name: COLE N E - KAt3 P-- Day Telephone: ( 389 — 4q-1 Mailing Address: 2000 tWO VN" GC70AKE t b Ol OWC4I ST. SEArtfLI✓ 1NA qf3 iy l City State Zip E -Mail Address. gten• kanze l vney -ar 6 ho .0 00A Fax Number: C t5 1lF — 4C) 4 O GENERAL CONTRACTOR INFORMATION - (Mechanical Contractor information on back page) Company Name: Ri" t4 Co"PA N y Mailing Address: X72.1 l3Z AcyPNVE NE lbe1- LZVUI✓ WA 9600S +, City State Zip Contact Person: INN D 6VeF_� -f Day Telephone: �� -2- 5) 1 - 6,(,040 E -Mail Address: i�eG yj!y G rain . CovY, Fax Number: f9,25� 0 Contractor Registration Number: BANG :' brr� (J 7 Expiration Date: * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record Company Name:- iN Mailing Address Contact Person: E -Mail Address: City Day Telephone: Fax Number: State Zip ENGINEER OF RECORD — All plans must be wet stamped by Engineer of Record Company Name: Iq k Mailing Address: City Stale Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: lapplicationstpcmtit application (7.2004) Paee 1 Z — Z J— W � JU 0 NO J I NW WO 95 tL Q N =) = I.. W Z I— Z� U� co_ o I— W W H H �O .Z W CO O Z r 1 i 1-11\ WELDING PERMIT INFORMATION — 206 - 431 -3670 Valuation of Project (contractor's bid price): $ '115 i 0 00 Existing Building Valuation: $ Scope of Work (please provide detailed information): MMOW 5C- eF4%L e Xtsrt0& WAbt -S ~1'p CMS ;TE cpEN OF "c-E A16A , UNS11wa New Wt A - M 'PoW %vvlzK ISCOAA . NEW 1 (FAiwr . CAF-�E-r ,0W V1 lL ��Bt3Eft J' 1A AND ACCU,9riC CC-ILJ J& 'Y -S) ANa o(:PIOC f4wrrURE sUteM . FEPLACe ALL 6K1S;rW& LI&H - T :r-IxTyV_es Alot? H W FowEpt Atiy PNrA UNbilz SerFtL&M T W IT. Will there be new rack storage? ❑ ..Yes �4 ...No If "yes ", see Handout No. for requirements. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single-family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ ..... Yes ; .. No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: ❑...Sprinklers - .Automatic Fire Alarm ... None ... Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ ...Yes No If "yes ", attach list of materials and storage locations on a separate 8 -112 x II paper indicating quantities and Material gafeo Data Sheets. lapplications\pertnit application (7-20W) Page 2 Z J_ 2 3U UO ct) CO W J W U WO J LL C! = W H Z� Z� 5 U� O� O F- W 111 2 �O W Z L) O Z Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC .1 Floor 16 I S 12)1 S 2 "d Floor 3` Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single-family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ ..... Yes ; .. No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: ❑...Sprinklers - .Automatic Fire Alarm ... None ... Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ ...Yes No If "yes ", attach list of materials and storage locations on a separate 8 -112 x II paper indicating quantities and Material gafeo Data Sheets. lapplications\pertnit application (7-20W) Page 2 Z J_ 2 3U UO ct) CO W J W U WO J LL C! = W H Z� Z� 5 U� O� O F- W 111 2 �O W Z L) O Z MECHANICAL PERMIT INFORMATION — 206 -431 -3670 4 �1 I MECHANICAL CONTRACTOR INFORMATION Company Name: - Mailing Address. Contact Perso E -Mail Address: City State Zip Z Z W UO U) to W J H CO LL WO LLQ U) �W Z F— Z� �5 U� ON 13 E— W W U. O Z W U =, O Z D,a3�'Telephone: Fax Number:_ Contractor Registration Number: * *An original or notarized copy of current Washington State _ Expiration Date: License must be presented at the time of permit issuance ** Valuation of Project (contractor's bid price): $ / i Scope of Work (please provide detailed information): F- 9 L 0 C^'I 1 _ :: LXIS-T Ilaro 'DUCTS Alb Nf'f FKi AS �ZQ V 1 Use: Residential: New .....❑ Replacement ..... F1 Commercial: New ..... El Replacement ..... F1 I Fuel Tyne Electric ...... ❑ Gas ..... 0 Other: 0 -3 HP/ 100,000 BTU Indicate type of mechanical work being installed and the quantity below: Unit T e: Qty Unit Type: Qty Unit Type: Qty Boiler/Corn pressor: Qty — Furnace<100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP/ 100,000 BTU F BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall /Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood Water Heater 50+ HP /1,750,000 BTU Heat/Refrig/Cooling System Incinerator - Domestic Emergency Generator Air Handling Unit <10,000 CFM Incinerator — Comm/Ind Other Mechanical E ui ment PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject i to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review— Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN U O I ENT: -`+' Signature: Date: 4 /U 2005 Print Name: L e Day Telephone: [20b) Mailing Address t wo ` MV4 1 ✓goAr-c - ( 0s UNIoN s-r GeATTL. , WA 92>1 o L City State 'Lip Date Application Accepted: Date Application Expires: Staff initials: \applications =11 application (7.2001) Paw 4 i City of Tukwila 000 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 ' Parcel No.: 0223100040 Address: 130 ANDOVER PK E TUKW Suite No: Applicant: HOMESTREET BANK i RECEIPT Permit Number DOS -147 Status: PENDING Applied Date: 05/04/2005 Issue Date: Payee: GLEN E. KANZELMEYER TRANSACTION LIST: I Type Method Description Amount - - - - -- -------- - Payment Check 4486 804.72 ACCOUNT ITEM LIST: Description, Account Code Current Pmts ------------------------ - - - - -- ---------- - - - - -- ------ - - - - -- BUILDING - NONRES 000/322.100 484.98 ' PLAN CHECK - NONRES 000/345.830 315.24 STATE BUILDING SURCHARGE 000/386.904 4.50 Total: 804.72 2811 05/04 9716 TTAL. 804-72 doc: Receipt Printed: 05 -04 -2005 z .- Z LU 00, CO) Uj J � W O; LL co) = W w � � o' oC D H- W UJ: F U� LL F.... W Z: U N; O Z Receipt No.: p R05-00628 Payment Amount: 804.72 J , 1 Initia{s: SKS Payment Date: 05/04/2005 02:03 PM l User ID: 1165 Balance: $0.00 Payee: GLEN E. KANZELMEYER TRANSACTION LIST: I Type Method Description Amount - - - - -- -------- - Payment Check 4486 804.72 ACCOUNT ITEM LIST: Description, Account Code Current Pmts ------------------------ - - - - -- ---------- - - - - -- ------ - - - - -- BUILDING - NONRES 000/322.100 484.98 ' PLAN CHECK - NONRES 000/345.830 315.24 STATE BUILDING SURCHARGE 000/386.904 4.50 Total: 804.72 2811 05/04 9716 TTAL. 804-72 doc: Receipt Printed: 05 -04 -2005 z .- Z LU 00, CO) Uj J � W O; LL co) = W w � � o' oC D H- W UJ: F U� LL F.... W Z: U N; O Z . ,..„y«:.x. H1:x \t �a..•�. \��.. ..v..:•t;"•{".;f;it�S{"r. ... ..... .. ,..... ,.� .. .. .. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PE T Q CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 P o ect: Type of Inspect r►. , Jac Address: Date Called: Special Instructions: Date Wanted: M. �[ m p.m. r � Requester: Pho o: ? . Approved per applicable codes. Corrections required prior to approval. Z �Z W JU U U O w= w 0 U. Q �d = W H _ Z W ~ - � p. U O N W ul H H ll! Z ff) O Z r INSPECTION RECORD � Retain a copy with permit ±0S ` M "7 INSPECTION NO. PERM 0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Pr j ct: S�v-c AA A Type of Inspection: Address: �� Date Called: q 6 ' Special Instructions: Date Wanted: S.._m� v M. Requester: / Phone No: Approved per applicable codes. Corrections required prior to approval. Prior to inspection, fee must be Q. Call to sechedule reinspection. 1 l i Z 1. ,� W J U U0 W Uj J C0 V_ W O, 9 J LL Q co) =a �_ Z F- l' - O Z F- . ?. �p ON � H W W . L Ill Z U= Z INSPECTION RECORD Retain a copy with permit �� INSPECTION NO. PER O. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 06)431 -3670 t P o'ect: Type of Insp ction: A ress: Date I ed: Special Instructions: Date Wanted: Requester: P ne No: Receipt No.: Date: FlM g.dO REINSPECTION FEE REQUIRED. F or to inspection, fee must be aid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. i Z Z' �QQ JU cU 0 CO 0. W= J CO) u_ W F} J . LL � � Z F H O Z F- fy U O N. WW ui Z U N O Z INSPECTION RECORD �- Retain a copy with permit INSPECTION N0. PE I N CITY OF TUKWILA BUILDING DIVISION , 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)4 1 -3670 A d : Type ; f Inspec 'o s::� Date Called: 2 lo Special Instructions: `I � !. W �A �Q 1 ' 7 '�� Date Wanted: `, �( ? I OY P.M. Requester: hone N p J i i 0 , Approved per applicable codes. Corrections required prior to approval. ; COMMENTS: I X f , i .. 'i t i S f Inspector: 7h S / 0� - j t n $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be Receipt No.: Date: Z W W� 3 L 0 0 W = t - U) W W 1 5: U. N� 1... W z f- W O W OM o I- WW p ll! z CO) p3: 0 z INSPECTION RECORD S _' Retain a copy with Qermit INSPECTION NO. PE IT W. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 , r Pr j ct: _ Type of Insp io Ades,, `V � Date Called' 7 c i Special Instructions: Date Wanted: m, ' ( ((! M. Requester: P 6h ;10 5 ID -`' s pproved per applicable codes. Corrections required prior to approval. COMM S: 1 Date' $5 .00 REINSPECTION �EE REQUIRE . Prior to inspection, fee must be p id at 6300 Southcent Blvd., Suit 100. Call to sechedule reinspection. ReAlpt No.: I Date: a Z F- J W W � JU UO 0 CO) i .- CO) LL W O. �5 U. Q co = C� �W F— O Z F—, W W U� O N . W W F- r W Z N O Z Of r City of Tukwila Fire Department '_,.. Thomas P. Keefe, Fire Chief Steven M. Mullet, Mayor 1908 TUKWILA FIRE DEPARTMENT FINAL APPROVAL.FORM FINALAPP.FRM Rev. 2/19/98 T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, " Wash ington 98188 • Phone: 206 -575 -4404 • Fax: 206 -575 -4439 z ~w D U ND CO w J I— co U- WO U. Q N� 2 �W Z H F- O z 1-. 25 U ON ON W H� LL O W z CO o� z d OEM o 0 cm 0 0 Oink 4�6 *444 r� 1908 May 16, 2005 City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director Mr. Glen E. Kanzelmeyer 2000 Two Union Square 601 Union Street Seattle, Washington 98101 RE: CORRECTION LETTER #1 Development Permit Application Number D05 -147 Homestreet Bank —130 Andover Park East Dear Glen: This letter is to inform you of corrections that must be addressed before your development permit(s) can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time, the Planning, Public Works and Fire Departments have no comments. Buildine Department: Allen Johannessen, at (206) 433 -7163, if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) complete sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will toot be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 433 -7165. Sincerely, Stefania Spencer Permit Technician encl xc: File No. D05 -147 sks Page 1 05/16/2005 TALinks\Docs\D05- 147\D05 -147 - Correction Letter # LDOC 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 Phone: 206 - 431 -3670 • Fax. 206 - 431 -3665 Z �w J D UO CO 0 C0 J � C0 U. w� LL¢ C �. = CY �w Z I. �O Z E— w D� O �. w w LL O. 111 Z 0 F... Z Determination of Completeness Memo Z z �w Date: May 10, 2005 J o Project Name: Homestreet Bank o Permit #: D05 -147 w Plan Review: Allen Johannessen, Plans Examiner -J = N w. W O A Building Division has deemed the subject permit application incomplete. To assist the . applicant in expediting the Department plan review process, please forward the following u. comments. = d PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 2436; all sheets shall be the r _ same size). ? �-- �O Z r-- w 1 The plans do not show the access to toilet rooms for the "Multiple" tenant spaces. IBC D o 2902.2.2 states: Access to toilets serving multiple tenants shall be through a common use p CO area and not through an area controlled by a tenant. o 2 Provide a complete floor plan of the building that shows the access to restrooms for the subject `w v tenant. CO U Should there be questions concerning the above requirements, contact the Building Division at p 206-431 -3670. No further comments at this time. I i I x z • Page 1 {� �.,��....i ....'.., �.��.,......: .�... ��.. ...., :.. .a�.�... .. ..».:.: i...•'...•.:..�..�i�.1..:<..A.a �t..r++...ti L.. c.f.. i.tii..��>`,r. Six: �t ur. ua;:« rr, x. ��. t, �., i�, �. A::. �LwS ,.Gb:".eti..+t�:r::�.:.:'o`.... w.;iF,.�iic...c.G�,.J i}�Lc s;d,.!.c.?u:, <....00w� .4w..wntir,!h.s... F..i�+.d.'wutikx +..i� 1�: PERMIT COORD COr- I( PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D05 -147 DATE: 05 -19 -05 PROJECT NAME: HOMESTREET BANK SITE ADDRESS: 130 ANDOVER PARK EAST Original Plan Submittal _Response to Incomplete Letter # X Response to Correction Letter # 1 Revision # after /before permit is issued DEPARTMENTS: 0-51" Bu di Usio I k Fire Prevention ❑ Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator A DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete ❑ Comments: DUE DATE: 05 -24 -05 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS R TING: Please Route 21 Structural Review Required REVIEWER'S INITIALS: Notation: REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS Approved ❑ Approved with Conditions Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: DATE: PERMIT COORD COPY Documents/routing slip.doc 2.28 -02 DUE DATE: 06 -21 -05 Not Approved (attach comments) ❑ ❑ No further Review Required DATE: z .I � W . �D. JU UO N J = H �W W� �j � = W z �_O w U� O� o�__ W w ~ E- �" O W z U N O z PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D05 -147 DATE: 05 -04 -05 PROJECT NA HOMESTREET BANK SITE ADDRESS: 130 ANDOVER PARK EAST X Original Plan Submittal — Response to Correction Letter # _Response to Incomplete Letter # Revision # after /before permit is issued DEPARTMENTS: / V 'yo -�5 l3u i Sion F* Public M A h DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete ❑ Comments: DUE DATE: 05 -05 -05 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Fire Prev ntion Structural ❑ PIPg Division Permit Coordinator TOES /THURS 7tructural ING: Please Route Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS Approved ❑ Approved with Conditions ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials : DUE DATE: 06 -02 -05 Not Approved (attach comments) PERMIT COORD COPY Documents /routing slip.dcc 2.20.02 �ai - `:rr. w� rw }da..�u :::d' T {;`iio { .'�.`if.'t care' y r+ d�ii•}, . r. si����±if�V ".A✓�.i?:4ikidAwf�,n l.r i }i''4,�fa' :,n, �,r >. �.hn —f „Ga (� .;f..0 «. *: .a'C'v ?ts- rtiG.+?�•;i�r rwntYr, l.�y" , ziw:r t .. ❑ No further Review Required DATE: z =z �w �U UO J = CO L 10 LL � = F- w _ ? ►— F- O z F_ W w 5 U O N, o �-. w U_ o W z co i^ F=- Z w City of Tukwila Steven M. Mullet, Mayor z Department of Community Development ) 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 48188 1 Phone: 206-431-3670 1908 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.iva. its Steve Lancaster, Director REVISION SUBMITTAL tr Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 19 /, M 2 Plan Check/Permit Number: D05 -147 ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name HOMESTREET BANK Project Address 130 ANDOVER PARK EAST Contact Person Glen Kanzelmeyer Phone Number: — 6go(0) 3m - L+416 Summary of Revision: COpdPtM PLO* PtAfJ OP tOI LPtMO PLVIPey W osl" FOK, OW Df *4-10 Wa, ON Sal" A 2.1 AND t5A5 tng:ye ot- * dN szftyrfi k 2.2 REeEmw +Cmr OF TUKM A Z J U. UO W= J f.. CO LL w O U. CO a. = w z 5 U � CO o i-- ww LL O U CO) O z MAY 1 9 2005 PERM e ENTER Sheet Number(s): PU Site "S A 2 •1 A2-- "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on - i �• -:_ .. DEPARTMENT:OF LABOR AND INDUSTRIES M REGISTERED AS PROVIDED BY LAW AS �. CONST CONT GENERAL. I� REGI ST ## °DATE CC01.- RAFNC * *061J7 04/20/2OQ6= �I EFFECTIVE DAT E' 04/2 i,. R A FN COMPANY 1721 132ND AVE NE. ' BELLEVUE WA 98005 -2250 F -052 - 000(8/97) Detach And Display Certificate REGISTERED AS PROVIDED BY LAW AS Please Remove CONST . CONT -GENERAL EXP . :.. REGI ST . # DATE And Si gn CC01 RAFNC * *061J7 04/20/2006 Identification EFFECTIVE DATE 04/27/1994 C ard Before ' Placing In RAFN COMPANY -: - -- Billfold 1721 132ND AVE NE BELLEVUE WA 98005. =2250 Signature Issued by DEPARTMENT OF LABOR AND INDUSTRIES J .NOTICE: IF THE DOCUMENT IN THIS FRAME IS LESS CLEARtHAN. o THIS NOTICE IT IS DUE TO THE QUALITY OF THE DOCUMENT. . PF File: D05 -0147 35 mm Drawing #1 -11 F Project Data PROJECT DESCRIPTION: TENANT IMPROVEMENT OF 1 SF EXISTING OFFICE SPACE: DEMOLISH SEVERAL EXISTING WALLS TO CREATE OPEN OFFICE AREA, CONSTRUCT NEW WALLS TO FORM WORK ROOM. INSTALL ALL NEW FINISHES (PAINT, CARPET, SHEET VINYL, RUBBER BASE AND ACOUSTICAL CEILING TILES) AND OFFICE FURNITURE SYSTEMS. REPLACE ALL EXISTING LIGHT FIXTURES AND PROVIDE NEW DATA CABLING. NEW ELECTRICAL AND DATA UNDER SEPERATE PERMIT, LEGAL DESCRIPTION: TRACTS 4 and - 5 ANDOVER INDUSTRIAL PARK NO. 2 ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 71 of PLATS, PAGES 68 and 69, IN KING COUNTY, WASHINGTfqLE COPY It Ift 022310004001 Plan mview approval Is subject tD errors and CODE DATA: APpml does not SITE ZONING: ' 70 2 SF WILA U SITE AREA: , (UNCHAN BY OCCUPANCY GROUP: B OFFICE Project Team TENANT HOMESTREET BANK, Corporate Services 601 Union Street, Ste 2000 Seattle, WA 98101 (206) 389 -4415 Glen E. Kanzelmeyer (206) 38q -6314 S ' GENERAL. CONTRACTOR Raf n Company 1721 132nd Avenue NE Bellevue, WA 98005 (425) 702 -6600 Tony Beaupre usan Ferrlby ELECTRICAL BUILDINGr OWNER VELA ELECTRIC 5614 7th Avenue �cp�_, Park East Building, Inc. Seattle, WA g810 REQUIRED FOR: 90q 5 336th Street, Suite 205 (206) 436 -5200 Federal Way, WA 98003 McChanical Chris Smith � Elecb�ral BJ Jenkins - (253) 661 -8095 Or Plumbing. NO Ch angos shall be made to the >scoplt � Gas Pip'in9 07 E^ o�k uu fthout prior approval of -._..d520 Building Division. CRY Of Tu W l a DOTE: Rc €lions will require a new plan submittal �IVISI a ON nd ma include additnal plan review fees. R ' Inch ins II�II (Illal1,�lllllll�lll(aLl- Llill� IL_ I I l 11.1.1..1.1 -1111 ' Hom eStre et Southcenter Mortgage 130 Andover Parkway E, Suite 101 v oce nit Map y 1 sWvaad BWd l q J „p �►s11 � �• # Evara� Bnac r .�1 r�,.. {S '. 4T w l SUarieltr 2 . R-! S''`kfi •} /Tj J. rrr �[f 20051WMPOW0. M. lne: ILS ` sheet Index • Issued o Issued for Reference Tukwila, WA 98188 Project Location 1 � FOR FEW 11R b. o m g � pg 7 __ f5 ` tA { `A 4 zoos a ��'I iF jMZ "rte, l fi'�UIiNil CS -01 Cover Sheet CB -02 General Notes CS -03 Abbreviations ARCW I TECTU RAL A1,0 Site Plan A2.0 Demolition Plan and Floor Plan A3.0 Reflected Ceiling Plan and Details 47.0 Interior Elevations 48.0 Details 49.0 Finish Plan and. Furniture Plan 1 � fi I (� I T j I I ) I ]_TI - LT1 311 rg 7 r N:SJl IIlI.... �1111I1 ( 1.LC[11�1IJlllll�,llll ' 1111. �11. 1i _III11�1_l�l(����IIIIIIIII�II► II w MONa t a It W a D NgEMMMDRAWINd DRAWN: gek CHECKED: gak fflaffea DATE : 4 May 05 F O •R : Perm it SHEET T I T L E Project Data Project Team Vicinity Map OF TUKWILA ',MIT CENTER OKI 130 Andover Park E Tukwila, Wa5hin4on , v ------ one �!�L!! ■= R 19 !�� M ` .ff F General Notes A. CODE5 I. The "International Building Code ", 2003 edition and all other applicable codes and authorities having jurisdiction shall govern design and construction. 2. All work of the Contractor shall comply with governing laws, codes, ordinances, rules and regulations of City, County, State and Federal ,jurisdictions. B. In the case of any conflict wherein the methods or standards of installation of the materials specified do not equal or exceed the requirements of the laws or ordinances, the laws or ordinances shall govern. Contractor shall notify HomeStreet of conflicts. 5A. DRAWINGS I. The Contractor shall carefully study and compare the contract documents and shall at once report to HomeStreet and the Construction Manager any error, inconsistency or omission discovered. 2. Plans which appear as backgrounds on civil, structural, electrical, mechanical, plumbing, landscape drawings, etc., are for the purpose of Illustrating general plan configuration. Such plans shall not be used for portions of the work other than that pertaining to the title of each sheet. Refer to the appropriate sheet for each specific portion of the work. 3. Repetitive features not fully drawn or .noted on the drawings shall be completely provided as if drawn in full. 4. Throughout the drawings are abbreviations which are in common use. The list of abbreviations provided is not intended to be a complete list. HomeStreet will define the intent of any in question. 5. DO NOT SCALE DRAWINGS. The Contractor shall use dimensions shown on the drawings and actual field measurements. Notify HomeStreet if any found. Note that dimensions are to face of structural sheathing on exterior partitions, face of finish ' on interior partitions and center line of structural columns unless obviously shown or marked otherwise. b. Verify all rough -in dimensions for all i eqp pment provided In the contract documents. Verify with HomeStreet the size, shape and utility reWirements of equipment provided by others. 7. All doors located next to a perpendicular partition and not located by dimension on plans shall be 4" from face of stud to edge of door opening unless noted otherwise. B. Wherever the word "Contractor" is used in the contract documents, it shall also include any Subcontractor, Sub - subcontractor or supplier engaged by the Contractor for any portion of work. C. PRE - CONSTRUCTION I. The Contractor shall perform a complete field review of existing conditions prior to construction. Any conditions that are found to be inconsistent with the documents or where the intent is in doubt, should be brought to the attention of NomeStreet for resolution prior to beginning work. 2. Each Contractor shall be responsible for the verification and coordination with other Contractors to secure compliance of documents and the accurate location of openings for mechanical, electrical and miscellaneous equipment, , B. Each Contractor shall be responsible for the joining of his work to the work of other trades. All deficiencies between trades shall be the responsibility of the General Contractor at no additional cost to WomeStreet. 4. The Contractor shall investigate and verify locations of structural, mechanical electrical and other existing conditions. Notify Wonn05treet of conflicts prior to construction. D GENERAL CONSTRUCTION I. The Contractor shall verify sizes and locations of all mechanical equipment pads and bases as well as power, water or drain installation with equipment manufacturers prior to beginning work. 2. The Contractor shall protect adjacent properties, utilities and improvements from damage. Should damage occur, the Contractor shall restore to previous existing condition at no cost to HomeStreet, B. All work shall be confined to property or area designated on drawing owned or leased by the permittee or party contracting with the permittee. 4. The constructions means, methods, technialues, sequences and safety programs connected with the I11Arle 1111) h. + ati _1• 11_ _ - • 5. The Contractor shall at all times keep the premises free from accumulation of waste material or rubbish caused by the Contractors operations. b, Where floor drains or Floor sinks occur, all finish floors shall slope to drain. 7. The Contractor shall store all construction materials and egpip T=t in areas designated by HomeStreet. B. The Contractor shall salvage all fixtures and mpipment for re - use on the project. Fixtures and equipment not used on the project shall be offered to HomeStreet prior to removal. q. All exterior wall openings, flashing, counter flashing and expansion joints shall be constructed in such a manner as to make them weatherproof • 10. Provide galvanic insulation between dissimilar metals. 11, All partitions shall extend to underside of structure above, unless noted otherwise. 12. All partitions shall be constructed with 3 1/2" metal studs at Ib" o.c., with 5/8" type Y GWB each side, unless noted otherwise. 13, The Contractor shall guarantee all work against fault of any material or workmanship For a period of not less than one year after acceptance. Faulty work shall be replaced All signage shall comply, as required, with the A.D.A. 14• The Contractor shall be responsible for providing blocking for all wall and ceiling mounted items, including all N.I.C. owners egpipment. 15. Provide furring as required to conceal mechanical and electrical work in £• FOR Samples of all iris t' �ANCE 16, Sam p finish materials and paint colors specified shall be s bmif ed eme5treet for approval prior to the beginning of work. , Dloonlis 17, All finish material shall comply with the flume spread class as iden Ufied in M 99 18, The Contractor shall Furnish shop drawings for Nomeareet a ZOe cabinets, millwork or other items regpiring custom shop fabricaattiaQ� prior to manufacture of any E. F IRE I LI FE SAFETY 1, Provide fire dampers at all • supply and return outlets, inlets or duct i Of • Tukwila assemblies, enclosures, partitions or floors as required by the fire d "N ._T__� . 2, Fire extiguishers are to be f urnished. and installed by the Contractor. Placement, location and number of extiguishers shall be determined by fire code officials. 3. Penetrations in assemblies requiring protected openings shall be fire Products and methods shall be submitted to building officials for approval prior to installation. 4. All exits shall be operable from the inside without use of a key or any special knowlege or effort, and shall be equipped with panic hardware where required or indicated. 5. All exit signs shall have letters min, (b) inches high and shall conform with applicable codes. b. All glazing shall be subject to Federal glazing standards. Glazing Subcontractor shall be responsiblolf for adherence to the requirements. The Subcontractor shall bring to the attention of HomeStAw any discrepancies before proceeding with work. F. PLUMBING/ _LFCTRI AL /MECHANICAL MAY I. Electrical/Telephone outlets shall be mounted vertically at +15 unless noted otherwise. PERM 2. All plumbing pipes in walls shall have acoustical insulation, 3. Mechanical contractor shall propose locations for thermostats and obtain approval from WameStreet prior to installation. 4. Coordinate all junction box and outlet locations with casework contractor. Junction boxes, outlets, conduits, receptacles, lights and all other electrical components required for power, lighting and data within casework shall be furnished by the electrical contractor, The Contractor is to review the casework shop drawings to verify the location, type and quantity of electrical and data components required for all casework items, S. The Contractor shall coordinate with HomeStreet supplied security data wiring, equipment and accessories to include but not be limited to: conduit, J -box and power requiements. b, The Contractor shall coordinate with HomeStreet supplied furniture systems to include but not be limited to: electrical and data wiring, J -box and wall connection requirements. IIIIIIII�III� .l(IIIIIIIIIII�EI il� Inch P x :06 " IIIll LIl. LILLIIIIIILILIIILL�ll1IILLLLLLI _LL . l .l.I LI 111.1_L11�1 LLLI `` V + r^ i 'r I i yF q y v M . + rar flE� O r� '7 Z 6 W0 l�. I LI�I � _LII I I I;I1l�1111.� h1l I�IIII� J II I II I i __...._ IIIIII�IIIII J 0 E W D 0 REVISIONS ORAWINI I r 13 •R : Permit SHEET T I T L E Cmeral Notes =1VED TUKWILA 4 ZU05 CENTER .r °'i` —' 1PROJECT � :T I T L E 5outhcenter Mortgage 130 Andover Park E Tukwila, Washington sam mm P 05 -OOG � M 1M8HEET N0. CS 00*101-TROM 00=141f. Owl WE, OF Abbreviations v I pffaw"M RE V181ONS � And E East m A gle EA Each LAM. Long/Length SPEC, Specification Laminate /Laminated 50. S quare Ems. Expansion Joint LAM, Center Line EL, Elevation(Ht) LT. Lavatory 50. FT. /SF Square feet LTG, # � Charnel ELEV, Elevator ELEC. Electric/Electrical Lighting S• Stainless Steel Z Number /Pound g ng 55K. Service Sink ° Pa y EQ. Equal — d S.T.C. So Transmission � L MAT, Material und smission Coefficient Perpendicular IE plate EQUIP. Equipment MAX STD, Standard ° Square EXIST. /(E) Existing Maximum STL. Steel ° Exterior MECH. Mechanical STOR. Storage o W Wide Flange' MFR. /MANUF. Manufacturer STRUCT. Structure/Stru MIN, Minimum ctural m . Suspended i A.B. Anchor Bolt F.D. ' Floor Foundation MI:�C. Miscellaneous SV. SUSP Sheet Vin l ° A/C Air Conditioning FE n MTL. Metal SYM, y o Fire Extinguisher Symmetrical Z ACT Acoustical Ceiling Tile F.E.C. Fire Extinguisher Cabinet N ! DRAWING A.D.A. American Disability Act F.F. Finish Face North T. Thermostat/Tread DRAWN k ADJ. Adjacent /Adjustable FIN. Finish/Finished , Not n Cont le T.A. Toilet Accessories N I C AFF Above Finish Floor FLR. Floor /Flooring NO. Number act T5• Towel Bar CHECKED: gek ALT. Alternate FLUOR. Fluorescent N,R,C, Noise Reductio TELE. Telephone � 1 e SUE ALUM, Aluminum F.O,C, Face of Concrete Coe fficient TEMP. Tempered/Temporary : ARCH. Architect /Architectural F.O.F. Face of Finish N. N S Not to Scale TAG. Tongue and Groove DATE 4 Ma 05 ASK Asphalt F.O.S. Face of Stud THK. Thick F o R : Permit F.O. I.C, Furn. by owner, inst, by contractor p; j : Center THR. Threshold BD, Board Outside Diameter f Parapet f S H E E T F.O,1,O, Furn, by owner, inst, by owner OPN, T.O.P. TOP Top �jT 1 T E BLDG. Building FP. Fireproofing �� T.O.S. Top of Slab BLKG. Blocking FT, Foot /Feet DZ � TPD. Toilet Paper Dispenser Abbreviations BM Boom FTG. Footing PART. Partition TYP. Typical BOT• Bottom FURN, Furnish/Furnished /Furniture PLAM. Plastic Laminat B/5 Building Standard a U.N.O. Unless Noted Otherwise BSMT, Basement PLBG, Plumbing UR. Urinal BTWN, G' Gas Plywood �n GA. Gauge PLWD, UTIL. Utility y B.U.R. Built Up Roofing GALV. Galvanized PR, Pair . G.B. Grab Bar P.S.F. Pounds per Square Foot VAC. Vacuum CAB, Cabinet G.F.R. Glass Fiber Reinforced P.S.I. Pounds per Square Inch V.B. Vapor Barrier CEM. Cement GI• Galvanized Iron T Pa r Towel D' V.C.T. Vinyl Composition Tile P CHBD, Chalkboard GL. Glass /Glazing . ispenser VERT. Vertical P CJT, Control Joint GLU LAM. Glue- Laminated (Timber) Pavement VEST. Vestibule CLG. Ceiling GR. CLO, Closet Qde R. Riser G.W.B. CLR. Clear V.T. Vinyl Tile �.., B Gypsum Wallboard R.A. Return Air ' W West C.M.U. Concrete Masonry Unit N/C W/ With CONC. Concrete H BPb R.B. Rubber Base R.C. Resilient Channel W.C. Water Closet COL' Column HCW Hollow Core Wood R.D. Roof Drain RECEIVED COMP. Composition HDR, Header REF. Radius WDO. Window CITY OF TUINV CONST, Construction REF. Reference /Refrigerator CONT. Continuous N.V.A.C, Heating/Ventilating/Air- Conditioning REINF. Reinforcing AY 0 4 2UU CONTR. Contractor HDWR. Hardware READ. Required W.G. W, Wire Glass W Water Heater W/O Without CORR. Corridor /Corrugated NMWD' Hardwood RES. Resilient WP, Waterproof PERPERMIT CENT Q CPT, carp Hollow Metal REV, Revision/Reverse W.R. Water Resistant C.T. Ceramic Tile HORIZ• Horizontal RM, Room WSCT. HT. Height R.O. Wainscot P RO J ECT 4 O Rough Opening WT. i ht L E DEMO, g Demolition I,D, Inside Diameter R Ided Wi re S South FO Reinforcing DF Drinking Fountain IN INSUL Insulation Solid Evil" �G� 5outhcenter Mo a e SCHED. Schedule �Z �p�` g DIA, Diameter . nsulation , Solid Core W '� C� i 3 DIM. SCW Dimension INS Install /Installed 0 Andover Park E S Soap Dispenser C 000 m�n D Down INT. Interior SEC. Section Tukwila Washln ton DR. Door• �j 9 D.S. .S Downspout JAN. Janitor Closet SN• Shelf /Shelves y Zoo DTL. Detail JNT. Joint SNT, Sheet M MSM R 0 J. N 0. DW Dishwasher JST. Joist SNTG, Sheathing .- 05 -006 DWG, Drawing SIM. '"N Simi w11� �8 H E E T N 0. Sink DWR, Drawer KPL. Kickplate SNK, 0r Slab on Grade 8 1 '0' N-Awl-W1111 W-1-WPI W MININ I�I�����I�lii�l� i11�111h1111f�1 11111 Inch 1/I6 �I v. i� 1. ��. I ~ r y ., IIIII 1 .1.11 1.1 III�IIILIIII'd11IIIIII I _I. 11111.1. II11111�1i� �il ( L11 1iIIII I I I II5 1 11111.1i111jiIII r lr? 4-- II� 11.1.1.1� IIII. �ll I1�11L111LII�1111��1J�1�11�II11I !_1)� '1 1111'11 i, I1III� 'i 'i iliiiill1111111111111I ppr REVI810N8 m II�� 111 IIIII� III I - 11 I II, II�IT Inch 1/16 I I I LI I I� I I I I I I I I_I_Ll i.l II,i i I I I I I I I I I I I,LLII I I I I:I L L� Lll I LIJ I I,l (.111.11.1.1'1 Site Scale: Plan 1 4 5 ' }I I Il ILI 111 Tjl jlI 'i i - � � �. 11 11i III , `3 ,'. 1 1 1��� t� I I - 6I Own F y { n tin inj1 t4 ^s "'ww4VC�4atit�{t�u z w� I I II 111 ILILI. IIlILIIII�IIIIIIILI�hlllllllll .�lll IILI�I1I LIIIIIIIIIIIIII�IIIIIIIII�III I a VIEWED FOR E COMPLIANCE J ' MAY 31 2005 l Ci Of Tukwila U pI1lISI0N_ CITY F T MAY 04 PERMIT CEN Z O W 0 W D DRAWING DRAWN: gak affmommm 1 8 8 U E D DATE : 4 may o5 Site Plan 14 ' .1 1PR0JECT T I T L E 5outhcenter Mortgage 130 Andover Park E Tukwila, Wa5hington 9 �::�{ M�. MEN; P R 0 J. N 0. 05 -006 m `km 8HEET N0. A1 ---- -- — JAMES C H R I S T E N S E -- N R O A D r 0 Demolition Scale: 1 8 :1 —0 2 Floor Plan Scale: 1/8 ,�. t) :. � ( - - - - -- �_ 1 �� ; �i�TI� ji]iliIi1i I1111 Inch 1N6 �.: > ,'!a 3 1 a 5I I 6I r rt�k ";� M Legend Walls Existing walls /partitions to remain. New partition: % type 'X' CWB each A side o/ % metal studs. Extend to underside of ceiling above or infill As w to match existing wall. S: indicates wall to receive sound insulation. = = = = == Existing wall to be demolished. Doors F� Existing door to remain. Relocate existing door from adjacent suite. Ir Existing door to be removed. Keynotes Q Remove counter and cabinets, salvage sink for reuse, discard faucet. Q Remove existing door and closet. Q New undercounter refrigerator, F.O.I.C. Q Reuse existing sink, install new faucet, connect to existing plumbing. Q New 74 ACX plywd, backerboard, fire treated, anchor to wall, 8 -D �� high, full length. © 4' -0 "x8' -0" wood f rarned dry marker board with tray. Q Relocated door and side lite assembly from suite 100. Q Server rack, F.C.I.C. Confirm rack type and size with laomeStreet prior to installation. �a 9.' II IIII�III I�IIII�IIIII IIIIIIIIIIIILILLIII�LIIL�LI _LL�LUL�I .. ' � �`� , , `�``:�� � ,,��'�: z IJI�.II�I�IIII�IIIl�_ IIII lII )�IIl I�LiLI�I:III�Illl�l! - II IIII 11111 I�'���I I�� ._._ II -. I IIIIIIIIIII�IIIII Plan RECEIVED CITY OF TUKWILA MAY 0 4 2UU5 PERMIT CENTER I m I I _o W o - I I I ld 0 a Z 3 DRAWING DRAWN: gek CHECKED: gek DATE : 4 May 05 F O •R : Perrn it 8 HEET f "T IT L E Demolition Plan Floor Plan Legend, Keynotes E NMI �■I i—ow Q PROJECT . IT I T L E 5outhcenter Mortgage 130 Andover Park E Tukwila, Wa5hington 8=2�'IMMc0PR0J. N0. 05 -006 8HEET N0. A2.0 81 m Z O_ It C� W G W D ' � -�� DRAW DRAWN: gak ATE :I q M 05 Floor Plan - West Key Plan s —%-':PROJECT 1T 1 T L E 5outhcenter Mortgage 130 Andover Park E Tukwila, Washington MONO PROJ. N0. 05 -006 &N.0 98' �' 8 H E E T N 0. A291 I�����I�IIII��I��I�I�I��III�III ,, �I I�III�rIR,�l,�l.11�l �I�I�11 j Inch 1/16 Y �i Z �(• 01 b IL II �II I I��L .III 5I III I 1 `�I���I I � I 6I h cc I ,7 W.7 (IIIIIII,III� III (IIIIIIIIIIIIIIIIII f 810NS REVIEWED FOR CODE COM PLIANCE A0000 I: MAY 3 1 2.005 City Of Tukwila BUILDING DIVISION CORREC ION tTR# j Z _O E3 m W O W 0 6 ,WINO Ei Inch 1/16 r r�` o() Floor Plan Scale: 1 8 ;1 —p __East - ---- I - - z 1 -. - - - - 1— - I � 1.. -1 - --I.- - . 5' 6I t. CRY O EE UKWILA essib" MAY 1 g 2005 let PERMIT CENTER { r �„ .`� PROJECT T LE 5outhcenter Mortgage 130 Andover Park E Tukwila, Washington " �PR0J. N0. 05 -006 HIMIREM 8HEET N0. A2 Key Plan F ...................... :: I uoo ■ ■ ■r■ nuuo n ■uuu■ ■■ 11 MAM W k .... _.. -... w■� ......... I .. WA� d ■� ,fit R .� ., ... �r nruuro■ � moo. u.::u u.0 ■ �■ � ' uurouu � uuuuu■ :: : :: :: :: :: ■Dour ■■ ■ (2) 12 GA. galv. slack wires dia. fixture corners, attach to structure above. Light fixture clips, attach to main runner @ each corner. (4) clips per fixture. 0 .............. ....... . - ............ Seismic De tail Scale: Not to Scale Scale: 1/8 :1' -0 Ceilin Finishe CITY OF MAY 04 2 Notes PERMITCEN Conference 102 Reflect Ceilin I Inch 1/1 1I M" I !r: =x2 tl ( , IS 5� b tt� Z o � �( ," �A Illllll�lill llll.l�.11.11l,llll�lllllll .l - I ILlI�� �IIIILL�LLLLULiL�LI1L Ceilin Off ice 103 ZeC ption 0 GWB, existing, PT -1 100 Q ACT -1 0 9 -10 a.f.f. Plan CISiII�II�tII�6I ( `w i�r�. ,,, � Y w.7 IIII 6 "I -1lIIIIIIIIII Iilll 11lll 1. Contractor shall obtain approval from owner for thermostat locations. 2. All ra pired exit signs shall conform with applicable codes. 3, Ceiling heights are from sub -floor to finished ceiling. 4. Contractor shall be responsible for providing emergency lighting, strobe lights, audiovisual alarms to meet all applicable codes, 5. For ACT seismic detail, refer to 3/A3,0 6. For light fixture seismic detail, refer to 2/A3,0 Pr End Panel v 1 VOW Work Room Scale: 3/8 1 —0 104 3 Conference 102 Scale: 3/8 1 —p I:'%- ) 9 Filler 3311 33 18 Filler 3 1 ill 7 1 _011 Verify 2 Work Room 104 Scale. 3/8": 1 —0 II�III.IIYiIi.�.111_..I.IIIIII I II III III I xIT III 1�I III 11 I�� il I IT, Inch 1/18 , i1, t ^ f 7yljt u 4 5 I 6I N (� {, (� t t - ih_ a� 1� 1 1� 1 •.0 r }a t �."r. l ��, " { � f' �l{ }i,+" ( 'y se L1 f IIIJ IILI�IIIIIIIII�IIIII Keynotes O Copier, F.0.1,0, Q Not Used. New undercounter refrigerator, F.O. I.C. Q Reuse existing sink, install new faucet, cornett to existing plumbing, Q Not Used, © 0- 0 "x8' -0" wood framed dry marker board with tray. General Notes All outlets in Work Room 104 shall be CFI or on a GFI circuit. Ay 3 � 245 ovot �, ra RECEIVED CITY OF TUK A MAY 0 4 2UO PERMIT CENTS 9 0 W 0 0 610N6 MEMISH DRAWING DRAWN: gek CHECKED: gek 196UED DATE : 4 May 05 Interior Elev Keynotes �f TROT L E 5outhcenter Mortgage 130 Andover Park E Tukwila, Wa5hington µ09T' 1 E PR0J. N0. 05 -OOG MM&MMS NEE T NO A7 3611 6 3611 36 18" Filler X= T. 00,/ A8.0 A8.0 CV 7 Filler 3311 33 18 Filler 3 1 ill 7 1 _011 Verify 2 Work Room 104 Scale. 3/8": 1 —0 II�III.IIYiIi.�.111_..I.IIIIII I II III III I xIT III 1�I III 11 I�� il I IT, Inch 1/18 , i1, t ^ f 7yljt u 4 5 I 6I N (� {, (� t t - ih_ a� 1� 1 1� 1 •.0 r }a t �."r. l ��, " { � f' �l{ }i,+" ( 'y se L1 f IIIJ IILI�IIIIIIIII�IIIII Keynotes O Copier, F.0.1,0, Q Not Used. New undercounter refrigerator, F.O. I.C. Q Reuse existing sink, install new faucet, cornett to existing plumbing, Q Not Used, © 0- 0 "x8' -0" wood framed dry marker board with tray. General Notes All outlets in Work Room 104 shall be CFI or on a GFI circuit. Ay 3 � 245 ovot �, ra RECEIVED CITY OF TUK A MAY 0 4 2UO PERMIT CENTS 9 0 W 0 0 610N6 MEMISH DRAWING DRAWN: gek CHECKED: gek 196UED DATE : 4 May 05 Interior Elev Keynotes �f TROT L E 5outhcenter Mortgage 130 Andover Park E Tukwila, Wa5hington µ09T' 1 E PR0J. N0. 05 -OOG MM&MMS NEE T NO A7 PF G� K? O 0 0 N U A7. PL -1 at All Exposed Surfaces French Cleat, Top 4 Bottom Recessed Metal Shelf Standards ca 314" Adjustable Plywd. Shelf, PL -1 N Brushed Aluminum Wire Pull, Typ. Under Cabinet Light w/ Valance er Cabinet Scale: 1 -11 _rill Lower A7.0 Sink I� Scale: 1 " — 1 0 c� cn c a 0 I N L A7.0 nI_rill ililil�l�-IIIiIi. �IIII�I_I�I f IiI II, ICI -I-Ii 111 I �I II�II� Ill III III I � II.I III l Inch 1/16 �I I' '2I � � � Y� 4 �' g, 8 a,. `. a,��Jtq IiIiIIIIIIIIIIIIILILIILIIII�III � �_ '�'��£ l � Z � w� I I I LL� I_I I I II I I I LLi.ILI I LLILI LI_Li I� (I LLI I (I I .LI I I I I III... I IiI�IL: IILLLi�I�IIILIIII����I�II( I�IL ►IIIIII�'I���I�����I�IIIIIII � iIIII v thk. Backsplash, PL -1 Pl ywd . Countertop, PL -1 Panel, PL -1 ied Aluminum Wire Pull al Plywd. Door, PL -1 RB -1 I _ In Foxed Shelf � CpMp� R 3/4" MAV 7 �OQS Shelf, PL -1 3 pity 0 vTSTp If r Under Cabinet Light w/ Valance m Z 0 Ild 0 0 ! DRAWING gek 3/4" Plywd. Countertop, PL -1 Under Counter Refrigerator Scale: 1 : 1' -0 3/4" thk. Backsplash, PL -1 3/4" Plywd. Countertop, PL -1 MEIM1 1 8 8 U E D DATE ; 4 May 05 F O •R : Perm it � 0�- '�'8 HT L E 6 _ Details 81ON8 Drawer w/ Heavy -Dut Full NMI Extension Glides Y � 11 k Brushed Aluminum Wire PulojTY of T ,° ILA Typical MAY 0 4 uo5 3/4" Adjustable Plywd . ShgiJ nlT I T PL -1 ER Recessed Metal Shelf Standards 3/4" Plywd. Door, PL -1 3ase, RS -1 Scale: 1" : 1' -0 4J r..r '� "(PROJECT : iT I T L E 5outhcenter Mortgage 130 Andover Park E Tukwila, Washington 2M- PR0J. N0. 05 -OOG HIM. '' `, 18 H E E T N 0. F AA =M cabinet C� PV Finish Scale: 1/871 V Plan Furnitur _ •. o Pl an � Scale: 1/8 -- Inch 1/16 2I I y 6 t {} � '' ���9V�� d66 ea rK++Ha+Nrf w S •J.� t �ty�.'�} t .:1 � . (` �-�. i h 1. ',• "�M,�...,w..;��i'J.! � �i } 4J1('.q�r Z 0 .1� ' E L L L 6 b �. 8, L 9�A ,^ .z w IIIIIIIIIIIIIIItILIIIILIIIIIIIII ll �f z w� I I I I LLI I I I I l I I I IJ L LLLI (LLIJJJ.ILLLI l I LLI l I l I_I I I I I I III.,.. I II(III IIII�IIIIIIIII� 'I I I Finish, Ke ti e 3 I RE 18113118 GENERAL FINIS -HES ACCENT AREAS } CPT -1 Floor Finish CPT -1 Floor Finish m WB -1 Base Finish VVe_1 Ban Finish PT -1 Walls Finish PT -1 Walls Finish z 0 Finish Schedule P -1 Benjamin Moore, Latex Enamel m Eggshell, #1065 0 P -2 Benjamin Moore, Latex Enamel Eggshell, Hampshire Gray, HC -101 0 RB -I Rdppe, P130 Buckskin, 4" cove i WB -1 Existing wood base , refinish IDRAW1No SV -1 Armstrong, Possibilities, Petit Point DRAWN: gek #86078 Sandpiper Beige CHECKED; ge CPT -1 Interface, Equilibrium, Custom Color 1 8 8 U E G Nexstep #141230250A backing, glue DATE . 4 May 05 down w/ menuf. premium adhesive, FOR Permit install w/ ashlar pattern a =11NUT S H E E T • 1 T I T L E PL -1 Nevemar ARP Surface, Shale Green, Matrix Textured #MR -5 -4T F Plan ACT- I Armstrong, Fine Fissured Second Look Furniture /Elec Plan II, White, 24 "x48" scored to look . . 24 "x24", Angled Tegular w/ 9f�" grid F Schedule face Electrical U d 1:0 Duplex put te �Jle P lW Ded l 4� outle� e."5q VID 1 Fourplex � utlet F< Phone jac Q� I-44 Phone /data 'ack _ -��� I-® Data Jack Q �`��� . 7U L Furniture syst MAY 4 2UU5 Electrical Notes PE R" CENTER O I. All wall mounted electrical outlets and M', o l p R J E C T Phone /data jacks to be installed 0 +18" A T I T L E to center of box U.N.O. (Heights called 5outhcenter Mortgage out on plan are to center of box). 2. Refer to Reflected Ceiling Plan, A3.0, for 130 Andover Park E additional electrical requirements. Tukwila, Washington 3. Electrical contractor shall provide all ,9 p R O J. N a. wiring infrastructure for signage, banking 05_006 4 security equipment. Coordinate with ,."` i,S HEET N 0. appropriate vendor(s). 4. Verify bank and security equipment power 4 data requirements, A9 16 0