Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D05-174 - KING COUNTY / METRO TRANSIT - FACILITIES - REROOF
KING COUN'T'Y FACILPTIES 11911 EAST MARGINAL WY S D05 -174 1908 Parcel No.: Address: Suite No: City o. Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: ci. tukwila. wa. us DEVELOPMENT PERMIT 1023049066 11911 EAST MARGINAL WY S TUKW Permit Number: Issue Date: Permit Expires On: Steven M. Mullet, Mayor Steve Lancaster, Director DOS -174 09/07/2005 03/06/2006 Tenant: Name: Address: Owner: Name: j Address: Contact Person: Name: Address: KING COUNTY FACILITIES 11911 EAST MARGINAL WY S, TUKWILA WA KING COUNTY 500 4 AV, #500, SEATTLE WA MARC DALLAS 201 S JACKSON ST, TR -0431, SEATTLE, WA Contractor: Name: HAIGHT ROOFING COMPANY INC. Address: 4910 15TH AVE NW, SEATTLE, WA Contractor License No: HAIGHRC269QK Phone: Phone: 206 684 -1332 Phone: 206 784 -8414 Expiration Date: 05 /11/2006 DESCRIPTION OF WORK: REROOF OF 35,290 SQ FT ROOF. NEW ROOF TO MEET R VALUES REQUIRED BY CITY OF TUKWILA (FM 1 -90, UL CLASS A) WITH METAL DECK; 4 INCHES POLYISOCYANURATE RIGID INSULATION BOARD MECHANICALLY ATTACHED; HOT MOPPED TYPE III ASPHALT ADHESIVE; 1/2 INCH FIBERBOARD INSULATION; 4 PLY MODIFIED BITUMEN BUILT UP MEMBRANE; FLOOD COAT OF APO MODIFIED ASPHALT IMBEDDED WITH GRAVEL AND FLASHINGS, CURBS, EQUIPMENT STANDS AND SHEET METAL COPINGS. Value of Construction: $300,000.00 Fees Collected: $4,327.47 Type of Fire Protection: International Building Code Edition: 2003 Type of Construction: Occupancy per IBC: Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: N Hauling: N Start Time: End Time: Land Altering: N Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: N Moving Oversize Load: N Start Time: End Time: Sanitary Side Sewer: N Sewer Main Extension: N Private: Public: Storm Drainage: N Street Use: N Profit: N Non - Profit: N doc: IBC - Permit D05 -174 Printed: 09 -07 -2005 Z = F' Z �7 D UO Co 0 wX V) U. w LL ?. � =w ZX H O w W V 0 0 — CO. .0 F--. W W HF LL0 Ill to O Z ;f i 'r City o Tukwila Department of Commuitity Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: ci.tulcwila.wa.us i Water Main Extension: N Private: Water Meter: N Public: * *continued on next page ** Steven Al Mullet, Maya Steve Lancaster, Directol- O� 12 t N 2 ,r iso8 �� City o.L rTukwila Steven M. Mullet, Mayor Departbnent of Contntuitity Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: ci.tukwila.wams Steve Lancaster, Director Permit Number DOS -174 Issue Date: 09/07/2005 Permit Expires On: 03/06/2006 Permit Center Authorized Signature: a/ Date: ( � 71d -Y I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not me to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the p ante of am autho 'zed to sign and obtain this development permit. Signature" '� "' �� Date: Q • 0 e> Print Name: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IBC - Permit D05 -174 Printed: 09 -07 -2005 I Z Z. �QQ � 3 U to o J H. Co tL W O LL Q co =d w. Z ZO w . moo 'O U, La w U �O Z U= Z City of Tukwila rasa Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 PERMIT CONDITIONS Parcel No.: 1023049066 Address: 11911 EAST MARGINAL WY S TUKW Suite No: Tenant: KING COUNTY FACILITIES Permit Number: Status: Applied Date: Issue Date: DOS -174 ISSUED 05/19/2005 09/07/2005 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: Prior to final inspection a written statement from the roofing contractor shall be required. The statement shall confirm the fire classification of the roof assembly that was installed. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: ** *FIRE DEPARTMENT CONDITIONS * ** 9: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 10: An operational permit is required to remove paint with a torch; or to use a torch or open -flame device in a hazardous fire area. (IFC 105.6.33, Chapter 3) 11: A minimum of one portable fire extinguisher complying with the International Fire Code and with a minimum 2- A:20 -B:C rating shall be readily accessible within 30 feet (9144 mm) of the location where hot work is performed. (IFC 2604.2.6) 12: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. 13: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 14: These plans were reviewed by Inspector 512. If you have any questions, please call Tukwila Fire Prevention Bureau at doe: Conditions D05 -174 Printed: 09 -07 -2005 �'': ,Mt....�: •. t.. J.'',: 4w�.: 5a: riuJ: i�t.' n:: l:: u+ �ri+ li:: it+. lti3i »a::.r1Y4�Yi.Lei..l`:lis7WiEk` - .. ..�,. .r .. „,= Z �z �w QQ J0 UO N J 3: U. w LQ cl) = a �w Z H t-- O Z H 5 U� ON DH_ w w LL 0 - -Z w 0 0�- Z City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 * *continued on next page ** Printed: 09 -07 -2005 doc: Conditions D05 -174 �.� 860 Cit y of Tukwila i Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performa ce of work. Signature. Date: Print Name: r� doc: Conditions 005 -174 Printed: 09 -07 -2005 I Z Z �W 2 D UO CO w =. J H CO U W O LL OC � • fN d = W O. z �— U� O - :0 I— W LLJ tL H —O W Z. CO O F-. Z. • r CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** King Co Assessor's Tax No.: 10 210 4 9 0 6 6 0 9 Site Address: 11911 East Marginal Wad' S. Tirkwi laSuiteNumbcr: 100 Floor: ground Tenant Name: King r'niini-�r iPa r I i -ieS New Tenant: ❑ ...... Yes @..No Property Owners Name: c/o METRO rPRANSTiT Mailing Address 201 S. Jackson St. MIS TR 0431 Seattle, WA 98102 City state Zip Name: MARC DALLAS Day Telephone: 2 0 6 8 4.13 3 2 Mailing Address 201 Sou:th J ackson St T —0431 S _a , WA 98104 City state Zip E -Mail Address Marc. dallas @metrokc. gov Fax Number: .684.1900 �.lh t ' �st , HI I �� � ilYi� �6�>n a " t - c " ni - - .ti'tc �idi���t�ftr 'a + l r Fet.'. Company Name: To. be determined @ notice of award Mailing Address City state Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance* Company Name: N/A Mailing Address City State Zip Contact Person: E -Mail A04ress Day Telephone: Fax Number: Company Name: John Davis PE — for King County Metro Mailing Address 201 S Jackson St MS TR -0433 Seattle, WA C)Rl n4 City state Zip Contact Person: +Tohn IIavi s Day Telephone: 206,694.1-970 E -Mail Address j nhn davi s @me t rnkr geiv Fax Number: 9 0 6. 6 8 a 1179 \applicationsVermit application (7.2004) Pape 1 Z ~ w JU UO to 0 N W W = H N LL WO L L co = W H Z� H O Z H W W U� ON OH WW H F- -O Z W U= O Z 11 1 A ... fif' M,, �w�`.. t,....; a,.° ik" 1t: 24^ 9v. il;``^"+' �7tN:.rr.ntar`!^ Way:«........+ �mnr' C+^ rr:+ r>. K^ n-.... t!*} L`••. a`*«; y,:"rwam5r? �pjami.. �iaen�> a:: rti' i�� ';4,�1,#'"+HY,r'�t,'i+�''..F, Valuation of Project (contractor's bid price): $ 3 4LL 0 40_ -0 0 Existing Building Valuation: $ 3. 5 tut; i i ; — Scope of Work (please provide detailed information): Please see a t tacherl 4 Page dPS1` -r t- i nn & dP -qGriptinn of existing r�Q o f SyStOM. sit. 0, .2, r ;j Will there be new rack storage? []..Yes [R...No If "yes", see Handout No. for requirements. 'Provide All I3iiildittg;Areas iit�S'gii'�r: "e Fittitagt.B'elow NSA Existin Interior Remodel Addition to - Existing `:: Siructtlre._ New ... ::: Type of ConsfiV6 'on ei IBC Type of Occupancy! per:. 1 Floor 2° Floor 3` Floor Flodrs thru Basement Accessory' Sh ucture* Attached Garage Detached Garage Attached Carport Detached Carport. . Covered Deck . Uncovered Deck PLANNING DIVISION: Single-family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? E] ..... Yes ❑ .. No If "yes ", explain: FIRE PROTECTIONMAZARDOUS MATERIALS: ❑ ... Sprinklers ❑ ... Automatic Fire Alarm ❑ ... None ❑ ... Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ... Yes ... No If "Yes"', attach list of materials and storage locations on a separate 8 -112 x 11 paper indicating quantities and Material Safety Data Sheets. bpplicatioWpemit application (7 -2004) Paee 2 t nk•:A'�a Y 3f�:� ak.il.SW.:.eUW r/..T. �.. uueW..iJYAHUIa`atsv >u�� +w a � •}. _ N^F i4.Mw z J~ z W UQ to W = H Co LL WO U— co = W Z f.. t— O z H W UJ UC3 O� O t-- WW H u. O tiJ Z' U= O f... z [:1 ... Right -of -way Use - Profit for less than 72 hours El ... Right -of -way Use- Potential Disturbance Scope of Work (please provide detailed information): .N / Call before you Dig: 1- 800424 -5555 Please refer,to Ptiblic Works.Bulletin #' fglt fees aiid','estimte sfie'e :x:: Water District ❑ ... Tukwila ❑... Water District #125 ❑...Highline El ... Renton ❑ ... Water Availability Provided Sewer District ❑ ...Tukwila ❑ ... Va1Vue El ... Renton El ... Seattle ❑ ... Sewer Use Certificate []...Sewer Availability Provided [].,.Approved Septic Plans Provided ❑ ... Septic System- For onsite septic system, provide 2 copies of a current septic design approval by King County Health Department. Submitted with Application (mark boxes which anplvl: ❑ ... Civil Plans (Maximum Paper Size -22" x 34 ❑ ... Technical Information Report (Storm Drainage) ❑... Geotechnical Report ❑ ...Traffic Impact Analysis ❑ ... Bond ❑ ... insurance ❑ ...Easement(s) ❑... MaintenanceAgreement(s) ❑ ...Hold Harmless Proposed Activities (mark boxes that a ❑ ... Right -of -way Use - Nonprofit for less than 72 hours ❑ ... Right -o f -way Use -No Disturbance ❑ ... Construction/Excavation/Fill - Right -of -way Non Right -of -way_ ❑...Total Cut cubic yards ❑ ... Total Fill cubic yards ❑...Sanitary.Side Sewer - ❑... Cap or Remove Utilities ❑ ... Frontage Improvements O.-Traffic Control ❑ ... Backflow Prevention - Fire Protection _ Irrigation Domestic Water ❑ ... Work in Flood Zone ❑ ... Storm Drainage ❑ ...Abandon Septic Tank ❑ ..,Curb Cut ❑ ...Pavement Cut ❑ ...Looped Fire Line m ❑ ... Permanent Water Meter Size... WO# ❑ ... Temporary Water Meter Size.. WO #_ ❑ ... Water Only Meter Size............ WO# _ ❑ ... Sewer Main Extension .............Public Private ❑ ... Water Main Extension .............Public Private ❑ ...Grease Interceptor ❑ ...Channelization ❑ ...Trench Excavation ❑ ...Utility Undergrounding ❑ ...Deduct Water Meter Size......... " FINANCE INFORMATION Fire Line Size at Property Line ❑ ... Water ❑ ... Sewer Monthly Service Billing to Number of Public Fire Hydrant(s) ❑ ... Sewage Treatment Name Day Telephone - Mailing Address City State Zip Water Meter Refand/Billing; Name Day Telephone Mailing Address City State Zip lapplicatiotis\prnnil application (7 -2004) Paee 3 Z •,_~ Z �W J U. 00 Cl) 0 CO) LLJ J = H CO) LL WO }} J L N d = W Z F- t- O Z H LLI W U5 0 0 0 H W LL -O itl Z' 0 O F- Z MECHANICAL CONTRACTOR INFORMATION Company Name: Mailing Address City State Zip Contact Person: Day Telephone: E -Mail Address Fax Number: Contractor Registration Number: Expiration Date: * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): Use: Residential: New .....C1 Replacement ..... F1 Commercial: New ..... El Replacement ..... ❑ Fuel Tyne Electric ......Q Gas..... Other: Indicate type of mechanical work being installed and the quantity below: UnitT e: Unit:T: e: ::Uitijf-,T "'e ; y:, _ ; 1l],:gilefJCoui' =Xe Fumace<100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood Water Heater 50+ HP /1,750,000 BTU Heat/Refrig/Cooling System Incinerator - Domestic Emergency Generator Air Handling Unit <I0,000 CFM Incinerator — Comm/Ind Other Mechanical Equipment Value of Construction —In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review— Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. I HEREBY CERTIFY THAT I HAVE READ AND EXAWNED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STA3r0F WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR A ORIZED A ! Signature: _ � _ °� r=• r Date: - �� Print Name: Marc Dallas Day Telephone: 0.6 . 6 8 4 . 13 3 2 Mailing Address 201 S. Jackson St. Seattle WA 981 City State Zip Date Application Accepted: Date Application Expires: Staff Initials: tapplicatirnutpcnnit application (7 -2004) Pace 4 Z Q� = Z �W 0 NO co UJ J � Cf) u_ WO �QQ LL Q N� = �W Z I•- ZO 5 U� O� O H WW H� O •Z W L) O Z ': ti:. E: i:: af4�siis7; ie: r.:,. 5 �?.: A. 4 . u' a`•":.: t;<ii4'.L fi'u ':wt• tiv_& City of Tukwila 19C8 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 i Parcel No.: 1023049066 Address: 11911 EAST MARGINAL WY S TUKW I Suite No: Applicant: KING COUNTY FACILITIES Receipt No.: R05 -01327 Initials: LAW User ID: 1630 RECEIPT Permit Number: Status: Applied Date: Issue Date: DOS -174 APPROVED 05/19/2005 Payment Amount: 2 Payment Date: 09/07/2005 02:02 PM Balance: $0.00 Payee: KING COUNTY TRANSACTION LIST: Type Method Description Amount Payment Check 41943 2,624.48 i ACCOUNT ITEM LIST: Description Account Code Current Pmts ------------------------ - - - - -- ---------- - - - - -- ------ - - - - -- BUILDING - NONRES 000/322.100 2,619.98 STATE BUILDING SURCHARGE 000/386.904 4.50 Total: 2,624.48 z : . i~ Z J U: 0 0, C0 f-. �LL w� �a5 U- 00 i a, �w Z f- I-- 0 z 1--. W UJ U � ON O 1-- W H LL. O i lL Z: co) 0 Z 6915 091083 0716 TOTAL 2624.48 doc: Receipt Printed: 09 -07 -2005 g City of Tukwila INS 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 1023049066 Address: 11911 EAST MARGINAL WY S TUKW Suite No: Applicant: KING COUNTY FACILITIES i Receipt No.: R05 -00729 Initials: SKS User ID: 1165 RECEIPT Permit Number: Status: Applied Date: Issue Date: D05 -174 PENDING 05/19/2005 Payment Amount: 1,702.99 Payment Date: 05/19/2005 02:08 PM Balance: $2,624.48 Payee: KING COUNTY TRANSACTION LIST: Type Method Description Amount Payment Check 4328 1,702.99 1 ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000/345.830 1,702.99 Total: 1,702.99 3,32.E 05 / 19 R1.6 i'VAL 1702.9 Z Z JU U O ca 0 : w= J S2 U. WO �E U- S2 d = z� 1- O z t— + �p O co, w W LL O i 111 Z V Co ' Z doc: Receipt Printed: 05 -19 -2005 r INSPECTION RECORD '1 Retain a copy with permit 7 7 INSPECTION N0. ;PE R TiNO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -360 Approved per applicable codes. Corrections required prior to approval. Project: -- Type of Insp Address: c Date Called: Special Instructions: Date Wanted: a.m. rn Requester: Phone No: COMMENTS: c f Jr $58.00 REINSPECTI.ON FEE REQUfRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. z F- �QQ W UO CO W J F = TLL WO 2� LLa = C! �W Z F— F— O z F-- �5 U� ON .0 F-- WW U AL 111 Z: co O Z INSPECTION RECORD Retain a copy with permit D05 /-7 t� I NSPEC ION NO. PER CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: _ I N �I O C C 1 N 1 F V . Type of Inspection: F- I\j r'E Address: 11 f 1 f Date Called: Special Instructions: Date Wanted: / a.m. Requester: Phone No: , Approved per applicable codes. Corrections required prior to approval. G COMMENTS: f r W er: Date: PECTION F REQUIRED.;P 'or to inspection, fee must be outhcenter Blvd., Suite 100. Call to sechedule reinspection. Receipt No.: Date: z Z. '~ W UO 0 ❑ to W J = N O' W� 9Q N� = W 1-0 W U Uj O CO. ❑ F— W W H ti O z CO) 1= _ o INSPECTION RECORD INSPECJJPN NO. Retain a copy with permit P' 'T CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (2 PER MI T CITY P ion Type 091ns Insp ection: Address: Date Called: 41 Special Instructions: 0/ Date W t d: 77-/L/ P. Requester FPFn e No: ;or") x NApproved per applicable codes. Corrections required prior to p val A a pro I. 19 COMMENTS: j Ifpe11R,: Date: 9EINSPECTION FEE QUIRED. Poor to inspection, fee must be j ai at 6300 Southcenter B[v Suite 100. Call to sechedule reinspection. Receipt No.: I Z Z JU 00 CO a co W W (D LL W 2� 1 :3 U. co I.- LLI Z 3: W W 2 5 D a 0 (D 0 WW 3:0 F- LL Z Z INSPECTION RECORD r Retain a copy with permit INSPECTION NUMBER PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East. Tukwila. Wa. 98188 206 - 575 -4407 Project: ��I G Type of nspection: Addres - Contact Person: Suite Pre -Fire: Special Instructions: V Phone No.: 2 " A / pproved per applicable codes. 1-1 Corrections required prior to approval. COMMENTS: n' Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: I ector: ' l� Dates Hrs.: $80.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be t 444 Andover Park East. Call to schedule reins ection. c ipt No.: Date: Word /Inspection Record Form.Doc 12/2/05 T.F.D. Form F.P. 85 z z �w Q D J 00 Cl) J = CO) LL w LLa N D 2 F w ?H z �- w U� O� w H� �O lil z UN H -r O z 3 D W.P. HICKMAf11 E L L 0 v E Paul Fannin SYSTEMS, INC. 15315 50th Avenue East •Tacoma, WA 98446 MAY 0 $ 2006 Office /Mobile: 206 -841 -ROOF • Fax: 253 - 531 -3584 E -Mail: fanninroof @comcast.net SOUTH SATELLITE OFFICF May 4, 2006 City of Tukwila Dept. of Community Development 6300 Southcenter BL, Suite 100 Tukwila, WA 98188 RE: R -Value Totals; 11911 East Marginal Way South, Tukwila, WA; Parcel No. 1023049066 To Whom It May Concern: Per your request, below is a breakdown of the R- values of each component of the specified roof system for the referenced facility. This R -Value total meets and exceeds Washington State Energy Code requirements for a gas heated facility. Material Description R -value Outside air film 0.17 Built -up membrane (aggregate surfaced) 0.33 ' /z" wood fiberboard 1.39 4" polyisocyanurate 20.00 Vapor Barrier Nom. Metal substrate Nom. Inside air film 0.61 Total R- value: 22.50 Please call with any questions. Sincerely, 7 aulnnin Senior Representative � TO I50`fpp X10 30700 Solon Industrial Parkway • Solon, OH 44139 el�,TTS.�rwMS 440.248.7760 • Fax 440.248.6524 • www.wphickman.com 1- PART 1 r 1.01 A. GENERAL SECTION 01010 SUMMARY OF WORK REVIEWED FOR CODE COMPLIANCE A0000 ED MAY ' 2 6 2005 SUMMARY City Of TWl�wila BUILD N DIVISION The work under this Contract includes furnishing all labor, materials and equipment necessary for the removal of the existing ballasted single ply roof and the installation of anew, complete, roofing system. B. Demolition work includes, but is not limited to, the following: removal of single ply roof membrane, rock ballast, flashings, sheet metal copings, Dads, expansion joint, wood blocking and other roofing components but leaving the existing polyisocyanurate insulation. C. Installation work includes, but is not limited to, the following: mechanically. attaching existing polyisocyanurate insulation to the metal deck, hot mopping 1/2 inch fiberboard insulation, applying 'a 4 -ply modified bitumen built -up membrane system with gravel weathering surface, flashings, curbs, equipment stands, and sheet metal copings. D. The total area to be covered is approximately 35,290 square feet not including walls or flashings. 1:02 PROJECT ADDRESS A. South Base Annex Facilities Building 11911 East Marginal Way South - Building C Tukwila, ,Washington' 98168 1.03 . CONTRACT TIME A. Construction' shall be complete and ready for use within 60 calendar days of the effective date of the Notice to Proceed. Schedule and conduct the Work in a manner consistent with achieving these purposes complying with the limitations of Work specified. Failure of the contractor to finish within the Contract time will result in damages in accordance with Section 0070.0, Article 9.7 of the Contract's General Terms and Conditions and Paragraph 1.14 of this Section. 1.04 TIME RESTRICTIONS A. Limit the hours of work to occur within the following schedule% Weekdays: 7 AM to 4:30 PM; unless noted otherwise. Weekends: Subject to approval by the Project Representative. 4/26/05 01010-1 C53065C 1.. ,�:. �.'.'Sw .� ,.,:5 ✓ e�«l.. :.xx. A�..N,h: 4,.t.1.[��...ul'MS'.wi l . V h'!• :; S'� �J f k '. �y4�..a ".�.,. z ~w JU UO N J = H C0 LL w o� �a Vd =w z �. ►- 0 w ~ w U 0- , oI.- wW F- L o ..z w �F 0 z B. The Contractor shall be liable. for the .premium costs of King County's overtime inspection for work performed outside of the regular work Hours listed.;above that has not been approved by the Project Representative. C. Limit deliveries of materials to between 9:00 a.m. and 3:00 p.m. 1.05* CONTINUITY OF FACILITY OPERATIONS A. The facility operates 24 hours a day, 5 days a week. Buses move throughout the facility to access scheduled transit routes, maintenance and repair facilities, and fuel/wash facilities. These operations occur on a tight time schedule which shall not be disrupted except under the conditions noted in this Section. i 1,06 CONTRACTOR RESPONSIBILITIES A. It is assumed that existing facilities ouitside the scope of the Contract are in good repair. Existing damage or defects shall be reported to the Project Representative immediately and prior to the start of Work. Damages caused by the Contractor shall be repaired and/or replaced to a condition equal to or better than that exisiting prior to the damage and to the satisfaction of the Project Representative at no additional cost to King County. 1.07 KING COUNTY RESPONSIBILITIES A. King County's operating personnel will be responsible for operating the existing facility throughout the performance of the Contract. Equipment presently installed in the .facility must be available to personnel at all times for use, maintenance and repair. If it is necessary in the course of operating the facility, for the Contractor to move -its equipment and materials or material included in the Work, the Contractor shall do so promptly and place such equipment or material in an area which does not interfere with the facility operation. The Contractor shall not adjust or operate King County's serviceable or functioning equipment or systems except as specifically required by this Contract.. Contact between King County's operational personnel and the Contractor shall be through the Project Representative or the Project Representative's designated representative. 1.08 PROJECT CONSTRUCTION COORDINATION A. Designate a representative to be on the site at all times during the construction. This representative shall be capable of giving direct field orders as the need arises. Official project communication shall be conducted between the Contractor's representative and the Project Representative. 1.09 PRECONSTRUCTION CONFERENCE A. Prior to beginning construction, a meeting of representatives of the Contractor and King County will be held. The purpose of the meeting will be to establish lines of authority and communication and identify duties and responsibilities of the parties. Discussion will cover specific Contract plans, specifications, unusual conditions, schedules of 4/26105 01010-2 C53065C• V. z '~ w D 00 J = F-- LL w LL � =w z� �0 w U� o- 0H wW 6o w z U= O z completion and other pertinent features of the Contract. Written notification of such a pending preconstruction conference will be made. 1.10 SPECIAL PRECAUTIONS A. Take special precautions to protect operating mechanical equipment, power supply and distribution equipment, and instrumentation equipment from exposure to weather, concrete dust, debris, dirt and water during the construction period. 1.11 ELECTRICAL WORK A. The Contractor shall use licensed electricians to perform electrical modifications if noted on the Drawings and in the Specifications. Electricians shall be available within four (4) hours, minimum, of request to modify roof top units or to repair any interruptions of service resulting from the Contractor's actions. In order to prevent water damage, interim repairs may be made by King County at the Contractor's expense. 1.12 PERMITS A. King County has received approval for a building permit from the City of Tukwila for the work to be performed under the terms, conditions, specifications•of this Contract. The permit requirements can be found in Section 01062 of this Contract. 1.13 SPECIFICATION LANGUAGE A. Portions of the Specifications are written in imperative and streamlined' form. This imperative language is directed to the Contractor, unless specifically noted otherwise. The words "shall be" shall be included by inference where a colon (:) is used within sentences or phrases. 1. Example a. Aggregate: ASTM D1863 b: Adhesive: Spray applied. 1.14 LIQUIDATED DAMAGES AGAINST CONTRACTOR A. Failure to achieve substantial completion within the Contract time will result in damages assessed against the Contractor in the amount of $200.00 per day for each day beyond the number of days established for completion. PART 2 MATERIALS Not used. PART 3 EXECUTION Not used. END OF SECTION z :J- Z w JU UO N C0 Uj J = C0 w w O. U- (0 = I w - _ z� E_- o z E- w LU o o -. 0 F- wW U � o LLi z U C0 O� z SOUTH BASE ANNEX FACILITY ROOF REPLACEMENT NARRATIVE May 17, 2005 FnJ Co" Location: South Base Annex - Facilities Building j . a n^^ 11911 E. Marginal Way South - Building C Tukwila, WA 98168 The 35,290 square foot roof at King County Metro Transit's South Base Annex Facilities Building has served its useful life and is showing signs of failure. It will be replaced in ` the summer of 2005. The existing built -up roof system consists of the following materials described Jro1_1r substrate to top layer RENle\ M C 1) Metal Deck (existing building structure) SOD 2) 4 inches of polyisocyanurate insulation 3) One layer EPDM single ply membrane MQ� 2 6 2005 4) Rock ballast surface Summary of Work ; Of �-uwwila Demolition and installation work includes, but is not limited to the fo lowi single ply roof membrane, rock ballast, flashings, sheet metal copings 1 sloe joint and wood blocking. These items will require disposal in a waste facility. The new roof that is being installed (FM 1 -90, UL Class A) will meet R values required by the City of Tukwila. The work will be done according to Chapter 15 of the International Building Code and will consist of the following material described from substrate to surface: 1) Metal Deck (existing building Structure) 2) 4 inches polyisocyanurate rigid insulation board mechanically attached 3) Hot mopped Type III asphalt adhesive 4) 1/2 inch fiberboard insulation 5) Hot mopped Type III asphalt adhesive 6) 4 ply modified bitumen built up membrane 7) Flood coat of APO modified asphalt imbedded with gravel as a weathering surface 8) Flashings, curbs, equipment stands, and sheet metal copings RECEIVED CITY OF TUKWILA There will be no structural changes made under this contract. j g 200 PERMIT CENTER P. Overby, Project Manager Metro Transit Division Design & Construction Section b5 -17q z �w D JU UO 0 CO) w w:r �LL w J U. ?. � =L ZO U C3H W � O .z w Cl) o �- z Pol MOEN eD 00 O CI1 O J ;NOTICE: IF THE DOCUMENT IN THIS FRAME IS LESS CLEARfitiAN MENT. THIS NOTICE IT IS DUE TO, THE QUALITY OF THE DOCU 4 W ct�`• 1908 04 - 03 - 2006 Ci ty of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director MARC DALLAS 201 S JACKSON ST, TR -0431 SEATTLE, WA 98104 RE: Permit No. D05 -174 11911 EAST MARGINAL WY S TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under.the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such pennit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection.. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve a one or more extension of time for additiona perios not exceeding 90 days each. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 05/13/2006, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, nuu Je ifer shall Permit Technician xc: Permit File No. D05 -174 i 1 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 Phone: 206.431 -3670 • Fax: 206 - 431 -3665 Z Z n: W JU U O Cl) 0, W= J X. NO W LL Cl) = }_ W . Z= H E O. Z H. W �5 U 0. 'O CO a WW 2 u O Z U CO: O Z nEIRMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D05 -174 DATE: 05 -19 -05 PROJECT NAME: KING COUNTY FACILITIES SITE ADDRESS: 11911 EAST MARGINAL WAY SOUTH X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after /before permit is issued DEPARTM ^,� �'y�) �l/5 Buil intDisision LM Public Works ❑ 1 z - No' 4.4' 0 5 Fire Prevention �] Structural ❑ Planning Division ❑ Permit Coordinator A DETERMINATION OF COMPLETENESS (Tues., Thurs.) Complete ( Incomplete ❑ Comments: DUE DATE: 0 - 24 -05 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ t=ire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS R UTING: Please Route Structural Review Required ❑ No further Review Required ❑ i REVIEWER'S INITIALS: DATE: 1 APPROVALS OR CORRECTIONS Approved ❑ Approved with Conditions i Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: PERMIT COORD COPY Documents/routing slip.doc 2.28.02 DUE DATE: 06 -21 -05 Not Approved (attach comments) ❑ z �z W 5 JU UQ CO CID W J H S2 LL W LL S2 C3 =W z ZO �vo co_ o H_ WW LL .z W U3 O E_ z i . Sent By: HAIGHT ROOFING CO INC; I . • r-625•D52,000 (07) 2087641058; Aug-2G 6 3:29PM; Page 3/3 DEPAR'rMENT OF LABOR AND INDUSTRTF . . .S REGISTERED AS PROVIDED BY LAW A S CONST CONT GENERAL t , -s " *" t ; � g r - T. A p, Ad HAIGHT tooFlWG'CompANy INC 4910 15TH*AVE N.W. SEATTLE WA 98107 1 4 I I 08/29/2005 MON 15•17 rTW/PW Nn ARA71 rAAAQ i i J S Z Fz. W . . 2 D U U 0 co) 0 cl) w w 1: co U- , WO 2 9:3 LL cl) cy� LU Z F— 0 Z w Lu. .2 5; . I :30 U cf) 0— .0 F— W L u 3: L ) Z F- Xll :0 F-" Z. Look Up a Contractor, Electri ,c�n or Plumber License Detail Page I of 3 Topic Index Contact Info Search Home Safety Claims It Insurance Workplace Rights Trades Et Licensing : Find a Law or Rule , Get a Form or Publication Look Up a Contractor, Electrician or Plumber General/Specialty Contractor A business registered as a construction contractor with I-Etl to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. License Information License HAIGHRC269QK Licensee Name HAIGHT ROOFING COMPANY INC Licensee Type CONSTRUCTION CONTRACTOR UBI 600142367 Verify Workers Comp Premium Status Ind. ins. Account Id Business Type CORPORATION Address 1 4910 15TH AVE N.W. Address 2 City SEATTLE County KING State WA Zip 98107 Phone 2067848414 Status ACTIVE Specialty I GENERAL Specialty 2 UNUSED Effective Date 11/12/1974 Expiration Date 5/11/2006 Suspend Date Separation Date Parent Company Previous License Next License Associated License Business Owner Information ...... ..... https://fortress.wa.gov/lni/bbip/Detail.aspx?License=HAIGHRC269QK 09/07/2005 z 5 JU 00 Cj) 0 LU CO W w 0 �Q CY, UJ z w C O UJ 5 C0 0 13 F- W Uj —0 .. Z' W C0 0 O X 0 F- z File,, ID DO5 -0174 35mm Drawing #1 -6 Pr / 0 1 E CL m C E V u 0 R m a U) 0 0 W N N V 7 i_ X; 'u `u a .m ul � M O V ID o .. i� O X V 0 CL .y O F N U V O CL /(5; >0 N D N 0 0 co ° o 0 IL DRAWING NUMBERING SYSTEM KEY: DISCIPLINE DESIGNATED CATEGORY G GENERAL 0 GENERAL C CIVIL 1 PLANS L LANDSCAPE 2 ELEVATIONS A ARCHITECTURE 3 SECTIONS S STRUCTURAL 4 ENLARGED PLANS M MECHANICAL 5 DETAILS FP FIRE PROTECTION 6 SCHEDULES & DIAGRAMS E ELECTRICAL 7 USER DEFINED T TROLLEY 8 USER DEFINED 9 3D VIEWS AREA LOCATION (FOR PROJECTS WITH C1 MULTIPLE LOCATIONS) DISCIPLINE DESIGNATOR SEQUENTIAL DRAWING NUMBER SEPARATOR WITHIN DISCIPLINE AND DESIGNATED CATEGORY VICINITY MAP SCALE: NONE LE BELLEVUE WAS on B 6 s? 0 405 ISS•QUAH RENTON • PROJECT M VICINITY • MAPLE VALLEY LOCATION MAP SCALE: 1 " = 200' STATE ROUTE 599 ................ -- N ACCESS ROAD TYPICAL . SECTION AND DETAIL REFERENCING SYSTEM: (1) THE SECTION IS CUT ON DRAWING A101: SECTION LETTER LETTER A105_ � / ELEVATION 10', '�L DRAWING ON WHICH SECTION /ELEVATION APPEARS. (2) ON DRAWING A105 THIS SECTION IS IDENTIFIED: SECTION LETTER SECTION DRAWING ON WHICH SECTION SCALE: 1 " =1' -0" A10 WAS TAKEN. (3) DETAILS ARE CROSS- REFERENCED IN A SIMILAR MANNER, EXCEPT THAT DETAILS ARE IDENTIFIED BY NUMBERS RATHER THAN BY LETTERS. I ABBREVIATIONS: I APPROX APPROXIMATELY HT HEIGHT MAX MAXIMUM MIN MINIMUM OC ON CENTER SS STAINLESS STEEL TYP TYPICAL W/ WITH V SOUTH BASE ANNEX FACILITIES ROOF REPLACEMENT LOCATION ki -I n o. SOUTH BASE FILE COPY GENERAL NOTES SHEET INDEX 1. CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE Permit N®® 2003 INTERNATIONAL BUILDING CODE AND THE LATEST D RAWI NG NUMBER DESCRIPTION EDITION OF THE TUKWILA BUILDING CODE. A COPY OF THE APPROVED PLAN, MUST BE ON SITE WHENEV a IS SUb` CONSTRUCTION IS IN PROGRESS. PP subje to e rrors a nd Omiss, � 01 GENERAL INFORMATION 2. IT IS THE SOLE RESPONSIBILITY OF THE CONTRA I Of Co nstructi on documerb doles not a11dWW2 STAGING PLAN TO INDEPENDENTLY VERIFY THE ACCURACY OF AL vkMbon of any adopt. � or ®t'rdlnaAce. R �01 ROOF REPLACEMENT PLAN BUILDING UTILITY LOCATIONS SHOWN AND TO FUR ©©��,t DISCOVER AND AVOID HARM TO ANY OTHER BUIL i Copy aW �$ a 1 01 ROOF REPLACEMENT SECTIONS UTILITIES NOT SHOWN HEREON WHICH MAY BE AFFECT D BY THE IMPLEMENTATION OF THIS PLAN. /� �A3.02 ROOF REPLACEMENT SECTIONS 3. THE CONTRACTOR SHALL TAKE APPROPRIATE STEPS By ,( R 3.003 3 REQUIRED TO PROTECT EXISTING BUILDING UTILITIES, ROOF REPLACEMENT SECTIONS EQUIPMENT OR BUILT -IN FURNISHINGS REMAINING IN THE WORK AREA DURING CONSTRUCTION. n 4. THE CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND LOCATIONS PRIOR TO START OF WORK. 5. ALL DEMOLITION DEBRIS MUST BE DISPOSED OF � LEGALLY, OFF SITE. aty0f BUILDING DIVISION aW FOP SOUTH BASE ANNE A0,0Q0V'P.D ROOF REP! ACEMENT Mh,y z0°b KING COUNTY Inch 1/16 1 7Y 1 1 A & s " + 5L b6 E6 Z6 66, `..06 L.I.IIL I IIILIII�IIIIILIL��IJ .IIIILII1�11- I.I_�hIlIJ ICI I'�I ICI I�r ICI I)i IIL III - III 'III. III III ICI (� �3J N� Q 6 r i i I I�I LII�IIIl�LII�I�llll� L III �IIII��II:I�I�Iill lflII SKID PAD 6',o ch a nnex :fin be rneds to thou scqm C , u:., W . % v-1 'tout prior approval of `-'_ _"� _ Ala Building Division. Revisions e;v�isio Is will require a new plan submittal and may include additional plan review fees. PROJECT DES CRIPTION OWNER: KING COUNTY AGENT: MARC DALLAS 201 S JACKSON ST, MS KSC -TR -0431 SEATTLE, WA 98104 -3856 206 -684 -1332 BUILDING USE: MAINTENANCE FACILITY CONSTRUCTION ROOF REPLACEMENT ONLY TYPE: REFERENCE: 2003 INTERNATIONAL BUILDING CODE RECEIVED CIYY OF TUKMLA MAY 1 9 2005 PERMIT CENTER FACILITIES METRO TRANSIT DIVISION °AiE SOUTH BASE ANNEX FACILITIES MAY 2005 BUILDING ROOF REPLACEMENT DRAWING NO: GENERAL INFORMATION Go.01 SHEET NM DI 1 6 PERMIT REVIEW — 6/05. FOR INFORMATION ONLY `�'° '►L9r 07• �4� ' GITAL r •�•� a b I - PULLET B FARISS- BATEMAN cHECKE°: R PUTNEY P OVERBY A 8 ISLER N315 ND: 432680.300 wow RT01 n 057 AS NOTED ONE INCH AT FULL SIZE I-- ----•4 '' IF NOT ONE INCH, SCALE ACCORDINGLY Count D King C un O Transportation No. REVISION BY APP'D DATE RECOMMENDED:. D CRIPPEN CONTRACT ND: C53065C SITE LOCAT)DN NO: SOUTH BASE ANNEX FACILITIES ROOF REPLACEMENT LOCATION ki -I n o. SOUTH BASE FILE COPY GENERAL NOTES SHEET INDEX 1. CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE Permit N®® 2003 INTERNATIONAL BUILDING CODE AND THE LATEST D RAWI NG NUMBER DESCRIPTION EDITION OF THE TUKWILA BUILDING CODE. A COPY OF THE APPROVED PLAN, MUST BE ON SITE WHENEV a IS SUb` CONSTRUCTION IS IN PROGRESS. PP subje to e rrors a nd Omiss, � 01 GENERAL INFORMATION 2. IT IS THE SOLE RESPONSIBILITY OF THE CONTRA I Of Co nstructi on documerb doles not a11dWW2 STAGING PLAN TO INDEPENDENTLY VERIFY THE ACCURACY OF AL vkMbon of any adopt. � or ®t'rdlnaAce. R �01 ROOF REPLACEMENT PLAN BUILDING UTILITY LOCATIONS SHOWN AND TO FUR ©©��,t DISCOVER AND AVOID HARM TO ANY OTHER BUIL i Copy aW �$ a 1 01 ROOF REPLACEMENT SECTIONS UTILITIES NOT SHOWN HEREON WHICH MAY BE AFFECT D BY THE IMPLEMENTATION OF THIS PLAN. /� �A3.02 ROOF REPLACEMENT SECTIONS 3. THE CONTRACTOR SHALL TAKE APPROPRIATE STEPS By ,( R 3.003 3 REQUIRED TO PROTECT EXISTING BUILDING UTILITIES, ROOF REPLACEMENT SECTIONS EQUIPMENT OR BUILT -IN FURNISHINGS REMAINING IN THE WORK AREA DURING CONSTRUCTION. n 4. THE CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND LOCATIONS PRIOR TO START OF WORK. 5. ALL DEMOLITION DEBRIS MUST BE DISPOSED OF � LEGALLY, OFF SITE. aty0f BUILDING DIVISION aW FOP SOUTH BASE ANNE A0,0Q0V'P.D ROOF REP! ACEMENT Mh,y z0°b KING COUNTY Inch 1/16 1 7Y 1 1 A & s " + 5L b6 E6 Z6 66, `..06 L.I.IIL I IIILIII�IIIIILIL��IJ .IIIILII1�11- I.I_�hIlIJ ICI I'�I ICI I�r ICI I)i IIL III - III 'III. III III ICI (� �3J N� Q 6 r i i I I�I LII�IIIl�LII�I�llll� L III �IIII��II:I�I�Iill lflII SKID PAD 6',o ch a nnex :fin be rneds to thou scqm C , u:., W . % v-1 'tout prior approval of `-'_ _"� _ Ala Building Division. Revisions e;v�isio Is will require a new plan submittal and may include additional plan review fees. PROJECT DES CRIPTION OWNER: KING COUNTY AGENT: MARC DALLAS 201 S JACKSON ST, MS KSC -TR -0431 SEATTLE, WA 98104 -3856 206 -684 -1332 BUILDING USE: MAINTENANCE FACILITY CONSTRUCTION ROOF REPLACEMENT ONLY TYPE: REFERENCE: 2003 INTERNATIONAL BUILDING CODE RECEIVED CIYY OF TUKMLA MAY 1 9 2005 PERMIT CENTER FACILITIES METRO TRANSIT DIVISION °AiE SOUTH BASE ANNEX FACILITIES MAY 2005 BUILDING ROOF REPLACEMENT DRAWING NO: GENERAL INFORMATION Go.01 SHEET NM DI 1 6 R Q Co a a 0 C� 0 ri 0 6 co m m E 0 a e nc w 0 0 of LL p N p �O 10 m a 0 iu U U- 0 U c a c m a CL 0 IL N C 2 _N U i v Y 0 CL No. N CONTRACTOR ) S PROPERTY LINE PROPERTY LINE X � X — — o� - -X �y, i ROOF ACCESS POINTS o 0 O STAGING AREA r CONTRACTOR PARKING SHEj -TER 1. MA TERIA, STORAGE - -- . -- . j - 1 WORK AREA a 0 131 11111 o L] L L I I Itti I I X X a X X - TROPERT1T= NOTE: EXISTING INFORMATION SHOWN ON THIS PLAN IS BASED UPON PRIVATE RECORDS SUPPLIED BY THE ORIGINAL PROJECT DEVELOPER /ENGINEER. NO GUARANTEE IS MADE AS TO THE ACCURACY OR COMPLETENESS OF THIS INFORMATION. NOR MAY ANY — ASSUMPTIONS BE MADE AS TO THE ACCURACY OF THE LOCATION OF ANY ENTITY SHOWN ON THE PLAN. 0' SCALE: 1 " = 40' REVISION BY IAPP - 01 DATE rp J O 0 0 r z m GRAVEL STORAGE Y, 20' a PERMIT REVIEW — 5/05 FOR INFORMATION ONLY a 432680.300 wow 11IOUEfir 05T -01 1 40' ONE INCH AT FULL SIZE I-- ' -— IF NOT ONE INC Ilill�il rllllll I�III��` - ICI i� I III Inch ,3I' l i -- 2 n l I 5 I 1116 Ih � 5 I s. si r'� d K� rr rhM ,e I I I 6 1 �' A M •�I 1 � 1 � '.' „r ' 1 � �i{ � � t } � {S.+'* �� * � i f t � ! �i� kr ` ° < 7 � '� 7 { � _ 7 �'',.^ � , •• �u i � tusr u� YY.awrfM'e��'* t t � 1 aft�y 5 6 ti 1 d L £ L 6� 8 �' C' FE Ya�Y {1vuU�dH4 al h �E� C+ w� �������I��111 ( IIII IIIi��� �IIII�IIL �������� .�.�����.� iliii���� iiii�� I�� ,�:,.. i ��:�� ����... ��� s �����1������-:- ������� ►I�����IIIII�l����i����l LE. GEND ff//Zm STAGING AREA REVIEWED FpR CODE COMPLIANCE A D�POUP MAY 2 6 2005 I City Of Tukwila BUILDIN D -, ! V ISI ON RECEIVED CITY OF TUKWILA M 1 9 2005 PERMIT CENTER METRO TRANSIT DIVISION SOUTH BASE ANNEX FACILITIES BUILDING ROOF REPLACEMENT Kin County STAGING PLAN Department of Transportation MAY 2005 GO.02 2 6 R Q 0 0 N C� Ln S N oD h O Q 3 O1 �D c+i O Q O c� O O IL rn c D m C m E 0) u O a d Od w O O Ce LL H 8 O 10 Co N M N U O LL L O h N �U O LL O u C 0 c o� c N a 1 CL L 2 N u m a 9 a Inch 1116 z grd3 ay,µ r °1 r7 x„ r 1 ,r�ctK r�r l ... 7 t �.• 5 !M't 't r „ , F ` 9 L L E 6 irr El Q �o N b: Ln G u� 0 ri Q 0 co Q 0 c* 0 IL v m c m E U U O a m 0 0 ce U_ N �o v m s n o N m U a m U c a c m c a i Q. 0 a �c 0 i N V Q� v CL No. c� z Y U 0 M z3 :2o .- m SPECIFIED ROOF MEMBRANE Xt" FIBERBOARD THERMAL INSULATION EXISTING METAL ROOF DECK EXISTING METAL WALL PANEL — EXISTING CONCRETE WALL 2x4 NAILER METAL COUNTER FLASHING W/ EXTRA BUTYL GASKET-----, POLYISOCYANURATE INSULATION " PLYW FASTENED TO WALL BASE FLASHING SPECIFIED ROOF MEMBRANE SEALANT \ , 4" MIN w z N NEW WOOD CANT Xz" FIBERBOARD NEW L- THERMAL INSULATION "-EXISTING METAL ROOF DECK INSULATION FASTENERS NEW INSULATION FASTENERS ROOF AT METAL WALL PANEL SECTION I IB� SCALE: NONE A1.01 SPECIFIED METAL COVER WITH RECEIVER FOR COUNTERFLASHING SET BOLTS IN SEALANT FASTENERS (APPROX CAPPE OC) NEOPRENE PAD REMOVABLE SHEET METAL COUNTERFLASHING _ FASTENERS APPROX 8" OC z EXTENSION OF FIELD PLIES ABOVE HEAD Z = OF CANT (NOT SHOWN FOR CLARITY) NEW CANT z SPECIFIE MEMBRANE E FLASHING (8 MIN HEIGHT) SPECIFIED ROOF MEMBRANE COVERBOARD INSULATION: Xt" FIBERBOARD THERMAL INSULATION EXISTING METAL ROOF DECK EQUIPMENT SUPPORT CURB SECTION r1 SCALE: NONE A1.01 REVISION STANDING SEAM SHEET METAL PARAPET CAP CONTINUOUS SHEET MEMBRANE LINER CONTINUOUS TAPERED WOOD SHIM (BEVELED CEDAR SIDING OR SIMILAR) SEAL TOP OF FLASHING WITH A 3- COURSE OF SPECIFIED MASTIC AND REINFORCED FABRIC PERMIT REVIEW — 5/05 FOR INFORb1ATI0N ONLY HIGH- DOMED, CAPPED, GASKETED FASTENERS AT ( APPROX 18" OC) FASTENERS APPROX 8" OC EXTENSION OF FIELD PLIES 2" ABOVE HEAD OF CANT (NOT SHOWN FOR CLARITY) NEW WOOD CANT SPECIFIED MEMBRANE BASE FLASHING (8" MIN TO 14" MAX HT). EXTEND MIN 4" BEYOND TOE OF CANT BY I APP'DI DATE DRAW BAND SEALANT —� APPROX X" CLEARANCE AT CORNERS —� NON- SHRINK GROUT SPECIFIED SEALANT OR MASTIC FELT ENVELOPE AROUND PENETRATION REQUIRED FOR COAL TAR , OR TYPE I do II ASPHALT ROOF ASSEMBLY — EXISTING METAL FRAME WINDOW METAL COUNTER FLASHING W/ EXTRA BUTYL GASKET 20 NAILER POLYISOCYANURATE INSULATION - -� " PLYWOOD FASTENED TO WALL BASE FLASHING SPECIFIED ROOF MEMBRANE SEALANT \ 4" MIN THERMAL INSULATION V) w L L N � N_ 1. A MINIMUM OF 2 FEET OF HORIZONTAL CLEARANCE MUST BE PROVIDED FOR REMOVAL AND REPLACEMENT OF ROOFING AND FLASHING BETWEEN PARALLEL SUPPORTS. A MINIMUM OF 3 FEET OF VERTICAL CLEARANCE FROM ROOF SURFACE TO BOTTOM OF SUPPORTED EQUIPMENT SHOULD ALSO BE PROVIDED. 2. PRIOR TO INSTALLATION, SEAL PENETRATION --- WUH-ELASTIC FILL. REVIEWED FOR CODE COMPLIANCE AV ;gyp MAY 2 6 2005 D CANT CI . I Qf •'t`ul.Wl a e V ION .�-. n.....�.,_, EXISTING METAL ROOF DECK ROOF AT WINDOW CITY OFTUKKIMIA SECTION �C1 MAY 1 9 20n5 SCALE: NONE A1.01 WATERTIGHT SHEET METAL RAIN COLLAR OVERLAPPING PENETRATION POCKET 24 GA SHEET METAL PITCH PAN, SOI DERED /WELDED WATERTIGHT (4" MIN HEIGHT) 4" MIN FLANGE, SET IN MASTIC AND FASTENED 3" OC OVER ROOFING PLIES, PRIME FLANGE BEFORE STRIPPING SPECIFIED MEMBRANE STRIPPING PLIES FIBERBOARD THERMAL INSULATION EXISTING METAL ROOF DECK �{ I--- 1" MIN PIPE DIAMETER PENETRATION POCKET SECTION �E1 SCALE: NONE A1.01 P OVER13Y I NONE ROUND PIPE COLUMN SPECIFIED ROOF W/ SOLDERED LEAD do MEMBRANE SHEET METAL HOOD. IF COVERBOARD NOT PRESENT, INSTALL INSULATION: 1z" PER SECTION E,(_ --- FIBERBOARD THERMAL INSULATION EXISTING METAL ROOF DECK �{ I--- 1" MIN PIPE DIAMETER PENETRATION POCKET SECTION �E1 SCALE: NONE A1.01 P OVER13Y I NONE � II I i �� I � Ii - l FULL SIZE 8 ISLER 24 as W. 1--- - 1 432680.300 IF NOT ONE INCH, nau noouan osT SCALE ACCORDINGLY CONWRACT N0: UM UXAPON NO: � II I i �� I � Ii - l HEIGHT OF LEGS UP TO 24 24 24" TO 48 36 48 ' AND WIDER 48'" x , II Illl�l�l II���I�II�I, f I w� II �IIIII EQUIPMENT SUPPORT CURB DETAIL 1�i1 SCALE: NONE A1.01 PERMIT CENTER STRUCTURAL FRAME t _ _w 0 J liJ La- = o WIDTH OF EQUIPMENT HEIGHT OF LEGS UP TO 24 24 24" TO 48 36 48 ' AND WIDER 48'" NOTE SEE DETAIL 1 METRO TRANSIT DIVISION °NTE 0 SOUTH BASE ANNEX FACILITIES MAY 2005 BUILDING ROOF REPLACEMENT King County ROOF REPLACEMENT o Department o SECTIONS sHM W . or Transportation 4 6 EXTERIOR ROOF BAY SECTION �q� SCALE: NONE A1.01 F TOP OF FLASHING CAPPED OR ROLLED INTO PIPE APPROXIMATELY 1" PLUMBING VENT STACK ►: Q a N O N O. O Uz 9 vi m a ri Q 0 9 CL CD CD c c m E a) U 0 a m 0 me U_ h co n m U r 0 i • U m U c 0 c a� `c `a f N Q) Q 0 C a i N v m Q a v S SPECIFIED SOFT METAL PIPE FLASHING. SEE NOTE 1 /_ SEALING MATERIAL SHEET METAL HIGH - DOMED, CAPPED, GASKETED FASTENERS ( APPROX FLASHING RECEIVER -� 18" OC MINIMUM TWO FASTENERS PER SIDE) REMOVABLE SHEET METAL COUNTERFLASHING SPECIFIED MASTIC OR SEALANT FASTENERS APPROX B" OC 4" MIN 4" MIN 6" MIN SET FLANGE IN MASTIC PRIME FLANGE EXTENSION OF FIELD PLIES ABOVE HEAD OF CANT FLANGE BEFORE STRIPPING z (NOT SHOWN FOR CLARITY) AF SPECIFIED MEMBRANE STRIPPING PLIES 4 MI 4" MIN _ � SPECIFIED BASE FLASHING (8" MIN HEIGHT) 7 N SPECIFIED ROOF 0 MEMBRANE l q� COVERBOARD W,W �4��w�� _ I AN INSULATION: )iw FIBERBOARD 04 MAINA , INSULATI THERMAL �iiG7 �� ROOF D ECK EXISTING METAL ROOF DECK REPLACE WOOD W II II NAILERS IF DAMAGED ----J u U NEW CANT PLUMBING VENT SECTION �A1 SCALE: NONE A1.01 _RAISED CURB FOR EQUIPMENT AND DUCTS SECTION t61 SCALE: NONE A1.01 MOTES: PLUMBING VENT 1. SHEET LEAD MINIMUM OF 4 LB PER SQUARE FOOT. REVIEWED FOR CODE COMPLIANCE MAY 2 6 2005 SPECIFIED LEAD FLASHING (30" SQUARE MINIMUM) SET ON STRIPPING PLIES IN MASTIC, PRIME TOP SURFACE BEFORE STRIPPING —, SPECIFIED MEMBRANE STRIPPING PLIES MULTI –PLY, ll BUILT –UP 1 ROOF MEMBRANE TAPERED INSULATION DECK CLAMP No. EXISTING METAL ROOF DECK THERMAL INSULATION COVERBOARD INSULATION: Y2" FIBERBOARD ROOF DRAIN - ALTERNATE FLASHING SECTION �C1 SCALE: NONE A1.01 REVISION BY IAPP'DI DATE CLAMPING RING DRAIN STRAINER DRAIN BOWL MEMBRANE, LEAD FLASHING AND STRIPPING PLIES ALL EXTEND UNDER CLAMPING RING PERMIT REVIEW — 5/05 FOR INFORMATION ONLY JIF���EXTENSION OF FIELD PLIES ABOVE HEAD OF CANT (NOT SHOWN • - �, SPECIFIED BASE FLASHING (8 MIN HEIGHT) jj� SPECIFIED ROOF MEMBRANE .i. i. i�i�i�i�w�w WWO — A MIN FIBERBOARD THERMAL INSULATION *. ��EXISTING METAL ROOF D ECK NEW CANT I RAISED CURB FOR LARGE HVAC UNIT SECTION �p1 SCALE: NONE A1.01 FLAT BAR TERMINATION BAR FASTENERS APPROX 8" OC FASTENERS APPROX 18" OC REMOVABLE SHEET METAL COUNTERFLASHING P R 8 432680.300 NONE ONE INCH AT FULL SIZE IF NOT ONE INC III ICI :.1..�1 .� - II ( III III I(I ill I�I ITR 1,1 ._.�... ..._«.. _ I l ( ) L, �L R { 1 1,1 I Inch 1/16 t 4,:. tir' 3 5 I < 96 bL EL Z1 LL 06 b�r I y r,''' Z L WO I LI I (I 1 1 1 1 1 1 LLLLI I Li I I I II 1 1 1 1 1 1 1 LLl ll I i l! I I L Ll l_LLI1.1 LLIJ.LIIi l (LIJ I I ` I 1 . 6!I 1 1 111 1 1 11 " l, (�� 1_ll.l.lh'Illllllil�l IIII�IIIII _IIlllllll�lllllllllllllll King County Department of Transportation City Of Tukwila BUILDING DIVISION REcem +OITY OF TUKML MAY 1 9 2005 PERMIT CENTER METRO TRANSIT DIVISION SOUTH BASE ANNEX FACILITIES BUILDING ROOF REPLACEMENT ROOF REPLACEMENT SECTIONS MAY 2005 M M A3.02 no: or 5 6 SCUPPER 1 • SUMP 2' AROUND SCUPPER OPENING TO PROMOTE WATER RUN OFF. 2. SCUPPER LINER TO BE MANUFACTURED FROM 24 GAUGE STAINLESS STEEL, AND ALL SURFACES THAT RECEIVE AN ADHERED MEMBRANE SHOULD BE PRIMED WITH ASPHALT PRIMER. 0. 9 ri 0 ri a d, Q 0 C7 A CL 0 C 'v �m i C U E 0 U O a m Be 0 0 o: N N U V. L O U m U C C a m t a a c a i U m a i B a � SEALANT/ SPECIFIED ROOF MEMBRANE MIN BACKER ROD IF NEEDED COVERBOARD INSULATION: Xz" FIBERBOARD THERMAL INSULATION EXISTING METAL ROOF DECK WOOD NAILERS AND CURB SPECIFIED BASE FLASHING SPECIFIED ROOF MEMBRANE SKYLIGHT. SCUTTLE, AND SMOKE VENT SECTION �q1 SCALE: NONE A1.01 SCUPPER SECTION SCALE: NONE A1.01 SPECIFIED ROOF MEMBRANE. EACH MEMBRANE LAYER EXTENDED TO PROVIDE MULTIPLE SEALS ROOF SUMPED WITH TAPERED INSULATION EXISTING METAL ROOF DECK TREATED WOOD NAILER RE V - " ®O . C ®MpLIA vf"4. #r' MAC � � 2D0a .�._ ---- �.� Tu4 �11 C��Y Bull -DIN No. REVISION DATE I PULLET PERMIT REVIEW — 5/05 a mi ss- FOR INFORMATION ONLY :�rf , CHUWM R PUTNEY (IIII�IIIj�h' Inch 1/16 ,2 � .. � 5� ti6 EL ZIP' 432680.300 � llI [ II IIIIIIIII I IIII 3. OUTSIDE EDGE OF SCUPPER SHOULD BE TOTALLY SEALED TO PREVENT WATER FROM ENTERING WALL CAVITY. 4. SCUPPER HEAD (NOT SHOWN) MUST BE BELOW OR HAVE SPILL -OUT BOTTOM LEVEL OF SCUPPER. 5. BREAK OUTSIDE TOP AND BOTTOM EDGES DOWN 45 DEGREES. 6. FLANGES SHALL BE A MINIMUM OF 6" WITH SOLID SOLDERED CORNERS. ,o - 2 -PLY STRIPPING FELTS NONE ONE INCH AT FULL SIZE IF NOT ONE INCH, ;CALE ACCORDINGLY Ring County TE L XA710N " Department of 1ranaportaUon RECEIVM Orry OF TUKMLa MAY 1 9 2005 PERMIT CENTER METRO TRANSIT DIVISION SOUTH BASE ANNEX FACILITIES BUILDING ROOF REPLACEMENT ROOF REPLACEMENT SECTIONS MAY 2005 A 3.03 SHM"m of 6 6 STANDING SEAM SHEET METAL PARAPET CAP 2 -PLY CONTINUOUS SHEET MEMBRANE LINER CONTINUOUS TAPERED WOOD SHIM (BEVELED CEDAR SIDING OR SIMILAR) c� _Z Y U HIGH - DOMED, CAPPED, GASKETED GASKETED FASTENERS MINIMUM FASTENERS AT APPROX 18" OC TWO FASTENERS PER SIDE m _Z3 FASTENERS APPROX 8" OC w .- m SHEET METAL COUNTERFLASHING SCUPPER LINER CONTINUOUS CLEAT EXTENDED FIELD PLIES ABOVE HEAD OF CANT (NOT SHOWN FOR CLARITY) CANT SS TRIM RING �� SPECIFIED MEMBRANE BASE FLASHING (8 SOLDERED TO SCUPPER SCUPPER LINER SET IN FULL BED OF MIN HEIGHT) FEATHERED AT FIELD OF ROOF ASPHALT PRIMER AND PRIMED WITH ASPHALT MASTIC � SEALANT/ SPECIFIED ROOF MEMBRANE MIN BACKER ROD IF NEEDED COVERBOARD INSULATION: Xz" FIBERBOARD THERMAL INSULATION EXISTING METAL ROOF DECK WOOD NAILERS AND CURB SPECIFIED BASE FLASHING SPECIFIED ROOF MEMBRANE SKYLIGHT. SCUTTLE, AND SMOKE VENT SECTION �q1 SCALE: NONE A1.01 SCUPPER SECTION SCALE: NONE A1.01 SPECIFIED ROOF MEMBRANE. EACH MEMBRANE LAYER EXTENDED TO PROVIDE MULTIPLE SEALS ROOF SUMPED WITH TAPERED INSULATION EXISTING METAL ROOF DECK TREATED WOOD NAILER RE V - " ®O . C ®MpLIA vf"4. #r' MAC � � 2D0a .�._ ---- �.� Tu4 �11 C��Y Bull -DIN No. REVISION DATE I PULLET PERMIT REVIEW — 5/05 a mi ss- FOR INFORMATION ONLY :�rf , CHUWM R PUTNEY (IIII�IIIj�h' Inch 1/16 ,2 � .. � 5� ti6 EL ZIP' 432680.300 � llI [ II IIIIIIIII I IIII 3. OUTSIDE EDGE OF SCUPPER SHOULD BE TOTALLY SEALED TO PREVENT WATER FROM ENTERING WALL CAVITY. 4. SCUPPER HEAD (NOT SHOWN) MUST BE BELOW OR HAVE SPILL -OUT BOTTOM LEVEL OF SCUPPER. 5. BREAK OUTSIDE TOP AND BOTTOM EDGES DOWN 45 DEGREES. 6. FLANGES SHALL BE A MINIMUM OF 6" WITH SOLID SOLDERED CORNERS. ,o - 2 -PLY STRIPPING FELTS NONE ONE INCH AT FULL SIZE IF NOT ONE INCH, ;CALE ACCORDINGLY Ring County TE L XA710N " Department of 1ranaportaUon RECEIVM Orry OF TUKMLa MAY 1 9 2005 PERMIT CENTER METRO TRANSIT DIVISION SOUTH BASE ANNEX FACILITIES BUILDING ROOF REPLACEMENT ROOF REPLACEMENT SECTIONS MAY 2005 A 3.03 SHM"m of 6 6