Loading...
HomeMy WebLinkAboutPermit D05-205 - MICROSOFT - COLO 4 TRAY3433 S 120 PL i i i 4 i City o ukwila Departmeyst of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: ci.tulnvila.wa.us DEVELOPMENT PERMIT Parcel No.: 1023049069 Address: 3433 S 120 PL TUKW Suite No: Tenant: Name: MICROSOFT Address: 3433 S 120 PL, TUKWILA WA Owner: Name: SABEY CORPORATION Address: 12201 TUKWILA INTL BLVD 4THFL, SEATTLE WA Contact Person: SEPARATELY) Name: BRIAN B. LAWRY Address: 1245 PEAR AV, MOUNTAIN VIEW, CA Contractor: Fees Collected: $518.28 Name: MCKINSTRY COMPANY Address: 5005 3 AV S, PO BOX 24567 Contractor License No: MCKIN * *372NO Steven M. Mullet, Mayor Steve Lancaster, Director Permit Number: Issue Date: Permit Expires On: Phone: D05 -205 07/22/2005 01/18/2006 Phone: 650 335 -1990 Phone: 206 762 -3311 Expiration Date: 01 /02/2006 DESCRIPTION OF WORK: COLO 4 EXPANSION TRAY PACKAGE. INSTALL CABLE TRAYS OVER (N) CABINETS AND RACKS (BEING PERMITTED SEPARATELY) Value of Construction: $15,000.00 Fees Collected: $518.28 Type of Fire Protection: SPRINKLERS /AFA International Building Code Edition: 2003 Type of Construction: VA Occupancy per IBC: 0008 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: N Hauling: N Start Time: End Time: Land Altering: N Volumes: Cut 0 c.y. Fill 0 C.Y. Landscape Irrigation: N Moving Oversize Load: N Start Time: End Time: Sanitary Side Sewer: N Sewer Main Extension: N Private: Public: Storm Drainage: N Street Use: N Profit: N Non - Profit: N Water Main Extension: N Private: Public: Water Meter: N doc: IBC - Permit D05 -205 Printed: 07 -22 -2005 Z Z� �2 u� D. UO N p UJ J U) w, w O. 9� LL ¢. co =d �w Z ZF_ w D o. U O CO D I_ w Lu =U LL O, t.. Z U N. Z City 6 kwila S teven M. Mullet. Mavor Departnteiit of Commuttity Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: ci. tukwila. wa. us Permit Number D05 -205 Issue Date: 07/22/2005 Permit Expires On: 01/18/2006 Permit Center Authorized Signature: Date: 0 712 "1 `' I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating I am authorized t sign and obtain this development permit. / 1� -7/ Signature: c =!M= Date: Z Z� Print Name: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doe IBC-Permit D05 -205 Printed: 07 -22 -2005 i Z i� Z � WD JU U O co w= J I -. LL W O J to D. = d, rw �o Z~ U� O N D I— _ LLJ. �O .. Z w U =: � I`- Z _ VtA i906 Cit y of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 PERMIT CONDITIONS Parcel No.: 1023049069 Address: 3433 S 120 PL TUKW Suite No: Tenant: MICROSOFT Permit Number: Status: Applied Date: Issue Date: D05 -205 ISSUED 06/15/2005 07/22/2005 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department of Labor and Industries (206/248- 6630). 6: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 7: ** *FIRE DEPARTMENT CONDITIONS * ** 8: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 9: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 10: All new srpinkler sysetms and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and /or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 11: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 12: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 13: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. 14: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of z �z � W UO C0 W J = F— N LL WO U. CO)� = d �w z F- f- O z� W W U ON o �- UJI w F- H LL O w z CO) O Z doc: Conditions D05 -205 Printed: 07 -22 -2005 �g Cit y of Tukwila f906 I ( Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 such condition or violation. 15: These lans were reviewed b In 512. If y ou have an p y p y y questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. * *continued on next page ** doc: Conditions D05 -205 Printed: 07 -22 -2005 r i 1 �g Cit of Tukwila Y Department of Community Development / 6300 Southcenter BL, Suite 100 I Tukwila, WA 98188 / (206) 431 -3670 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Date: d � doc: Conditions D05 -205 Printed: 07 -22 -2005 F=4m- - � ILA j Igoe CITY OF TUKWILA,,,,, Community Developmeri epartment Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** t. King Co Assessor's Tax No.: 10.2 3 0 4 — 9 0 6 9 Site Address: 3433 South 12 Pth Place Suite Number: Floor: 1 Tenant Name: M s of t • New Tenant: ❑ .... Yes ®..No Property Owners Name: I n t e r n a t i o n a I Gateway East • LLL Mailing Address: 12201 Tukwila International Way Seattle, WA 9 8168 City State Zip Name: Brian B. Lawry Day Telephone: 6 5 U — 3 3 5 19 9 u Mailing Address: 1245 Pear Avenue'Mountain View, CA 94043 City State bblawry @gpdinc.com Fa 650- 335 -1988 zip E -Mail Address: Fax Number: GENERAL CONTRACTOR INFORMATION (Mechanical Contractor infortnaf><on on _back page) r. Company Name: M c K i n s t r ARC °HITECT'OF !RECORD` All plans musf ewe amp t sted by Ar`chi ect of Record Y ry . Mailing Address: 5005 3rd Avenue South Seattle, WA 98134 City State Zip Contact Person: Danny H o r.t o n Day Telephone: 206-832-8138 E -Mail Address: DanHo @MeKinstry.com Fax Number: 206- 832 -8592 Contractor Registration Number: Expiration Date: * *An origntal or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** ENGINEER OF RECORD —Ail plans must'bc, .,, stamped!by Engineer of Record `,! City State Zip Contact Person: Brian B. Lawry Day Telephone: 650-335-1990 E -Mail Address: bblawry@gpdinc.com Fax Number: 650-335-1988 Company Name: Gordon — Prill, Inc.... Mailing Address: 1245 Pear Avenue Mountain View, CA 94043 1 Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: \permits plus\icc changeslpermit application (7 -2004) Page 1 AM i F, l� Z '~ W JU UO W� N LL WO Q � Q LL ? N = W Z f. F_ O W U� C0 C3�_ WW LL —z CO O Z Will there be new rack storage? ❑ .. Yes K. No If "yes ", see Handout No. for requirements. Provide All Building Areas:in Footage_Below PLANNING DIVISION: Single- family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: yG Compact: Handicap: Will there be a change in use? ❑ ....YesX ..No 'If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: (j A/O J9.. Sprinklers ,9 ..Automatic Fire Alarm ❑..None ❑ . Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ .. Yes ❑ .. No If "yes ", attach list of materials and storage locations on a separate 8 -112 x 11 paper indicating quantities and Material Safety Data Sheets. %permits phaVcc ehangakpennit application (7 -2004) Page 2 Z W Q� JU U to o �LL WO L N CY = W H O W ~ W U O -. WW u. O. Z W(D U O F- Z tBUILDING PERMYT�NF"��tMATYON 206 431 366 - - i 1 Valuation of Project (contractor's bid price): $ 0,000 Existing b, ,,ding Valuation: $ Scope of Work (please provide detailed information) 7may Existing Interior Remodel Addition to Existing Structure New Type of Construction pef IBC Type of Occupancy per IBC 1 :`.Floor:.- 116,079 2 n .:Floor 3. Floor ..:.:. , ... Floors 'thrti : - , :$asement':: Accessory. Structure *.:. - 'Attached Garage, :Detached Garage - Attached Carport. - Detached:CaT it .Covered Deck- .. . -Uncovered Deck PLANNING DIVISION: Single- family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: yG Compact: Handicap: Will there be a change in use? ❑ ....YesX ..No 'If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: (j A/O J9.. Sprinklers ,9 ..Automatic Fire Alarm ❑..None ❑ . Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ .. Yes ❑ .. No If "yes ", attach list of materials and storage locations on a separate 8 -112 x 11 paper indicating quantities and Material Safety Data Sheets. %permits phaVcc ehangakpennit application (7 -2004) Page 2 Z W Q� JU U to o �LL WO L N CY = W H O W ~ W U O -. WW u. O. Z W(D U O F- Z tBUILDING PERMYT�NF"��tMATYON 206 431 366 - - i 1 Valuation of Project (contractor's bid price): $ 0,000 Existing b, ,,ding Valuation: $ Scope of Work (please provide detailed information) 7may ,tea. �VIECHANICAL PERMIT INFO NATION - 206431:670 a , MECHANICAL CONTRACTOR INFORMATION Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance" Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): Use: Residential: New .... Q Replacement..... Unit Type: Commercial: New .... ❑ Replacement..... ❑ Fuel Tyne Electric ..... ❑ Gas .... ❑ Other: Indicate type of mechanical work being installed and the quantity below: Unit'T e: Qty Unit Type: Qty Unit Type: Qty Boiler/Compressor: Q Furnace <100K BTU Air Handling Unit >I0,000 Fire Damper 0 -3 HP /100,000 BTU CFM Furnace>100K BTU Evaporator Cooler Diffuser - 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected Thermostat 15 -30 HP /1,000,000 BTU to Single Duct Suspended/Wall/Floor Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Mounted Heater Appliance Vent Hood and Duct Water Heater 50+ HP /1,750,000 BTU Repair or Addition to Incinerator - Domestic Emergency Heat/Refrig/Cooling Generator System Air Handling Unit Incinerator — Comm/Ind Other Mechanical <10,000 CFM I I I I Equipment PERMIT APPLICATION;NOTES Appl><cable to :all perm><ts ><n tbis app cat><on : Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Mailing B. Lawry 1245 Pear Avenue Mountain View, CA Date: 6 Z Z151 Day Telephone: 650-335-19§0 94043 City State Zip Date Application Accepted: Date Application Expires: Staff Initials: 1pertnits phulicc changeslpermit application (7 -2004) Page 4 l� Z Z �W UO N 0 CO U.1 J = F— N LL WO LL Q N =11 2 l .- u.l Z E- H- O Z N w �5 U� ON OH W H L). tL —0 .. Z W U= O F- Z i i i �.wtiu, w City of Tukwila V f9p8 6300 Southcenter BL, Suite 100 / Tukwiia, WA 98188 / (206) 431 -3670 RECEIPT Parcel No.: 1023049069 Address: 3433 S 120 PL TUKW Suite No: Applicant: MICROSOFT Permit Number: Status: Applied Date: Issue Date: DOS -205 APPROVED 06/15/2005 Receipt No.: R05 -01080 Initials: LAW User ID: 1630 Payee: MCKINSTRY CO Payment Amount: Payment Date: Balance: 315.88 07/22/2005 02:53 PM $0.00 TRANSACTION LIST: i Type Method Description Amount '. ---- - - - - -- -- - - - - -- --------------------- - - - - -- ------ - - - - -- Payment Check 315.88 315.88 i ACCOUNT ITEM LIST: Description Account Code Current Pmts j ------------------------ - - - - -- ---------- - - - - -- ------ - - - - -- BUILDING NONRES 000/322.100 311.38 j STATE BUILDING SURCHARGE 000/386.904 4.50 ti f Total: 315.88 ? 5250 07/22 9716 TOTAL 315.88 doc: Receipt --- -- - Printed: 07 -22 -2005 1 s zz }� Z , L) O. CO C3 U) -r� J P S2 LL W� LL ?' Co C7 = iuI �- _, ir- O z H W LIJ U� O N 0 W W` L Z 11J U N,, O ~' z I City of Tukwila I 196 i 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 1023049069 Address: 3433 S 120 PL TUKW Suite No: Applicant: MICROSOFT RECEIPT Permit Number D05 -205 Status: PENDING Applied Date: 06/15/2005 Issue Date: Receipt No.: R05 -00880 Initials: SKS User ID: 1165 Payment Amount: 202.40 Payment Date: 06/15/2005 09:29 AM Balance: $315.88 Payee: GORDON- PRILL, INC. I. i TRANSACTION LIST: i Type Method Description Amount Payment Check 1677 202.40 ACCOUNT ITEM LIST: Description Account Code Current Pmts ------------------------ - - - - -- ---------- - - - - -- ------ - - - - -- PLAN CHECK - NONRES 000/345.830 202.40 Total: 202.40 i V doc: Receipt Printed: 06 -15 -2005 7 Z' Z U O ' co) CY wi J � CO) L W O H =. � Z �— W UJ U� ,O N, D I-- WW H V W f' .. Z. W N H =' O ~` Z INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: g � Type of Inspection: l Address;- � ,.,,t,�. Date Called: Special Instructions: Date Wanted: •'"�� V �� a`. Requester: Phone No: i i Receipt No.: Date: Z H W MQ W J0: UO (1) 0 w= S2 LL W O � QQ LL = W ZH H O W I— W UO O (1); W UJ u. O ttl Z CO) O Z u paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspectior .v3Nt- ... INSPECTION RECORD ' Retain a copy with permit INSPE ION NO. PE IT CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Pro'ect:� /?'- (" )1> ad= Type of Ins lion: e [Special 3 3 5 ate CaII d: --- /C structions: ^• �� / � n t Date Wanted: M. Requester: Ph ne N� i I Receipt No.: Date: Z �Z J V L) 0 ' ,A Q' w= J iH W W' WO J W Q' = Cy �W Z =. H 1— O` W �Q UJ '0 C/) 01•-. WW .O .. Z W N F— H O Z `'—' paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspectic = 1 1 1 ' • � 11 1 1 - City Of Tukwila Steven M. Mullet, Mayor Fire Department Thomas P. Keefe, Fire Chief TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Auth Signature FINALAPP.FRM Rev. 2/19/98 Date T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206 -575 -4404 • Fax. 206.575 -4439 z '~ w � JU UO CO co W J = H �U- w J LL Q N = = a F w z �O z E- LU U� ON 0 !-- WW H LO . Z. w U =` O Z ARMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D05 -205 DATE: 06 -15 -05 PROJECT NAME: MICROSOFT SITE ADDRESS: 3433 SOUTH 120 PLACE X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision #_after /before permit is issued DEPARTMENTS �m % AW Build'iNc Div "isIon 0 Fire Prevention ❑ Planning Division ❑� Publir, Works , I, 0 W 'O s Structural ❑ Permit Coordinator Q DETERMINATION OF COMPLETENESS (Tues., Thurs.) DUE DATE: 06 -16 -05 Complete [ Incomplete ❑ Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TOES /THURS RROTING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS DUE DATE: 07 -14 -05 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: PERMIT COORD COPY Documentstrouting slip.doc 2.28.02 z z Q w W 0 UO Cl) 0 C0 W J = S2 U_ w 0 U. 0 S2 a �w z �0 zi_ LLI w U ON 0H wW LL O ill Z U= O Z Look Up a Contractor, Electrician car Plumber License Detail Page I of 4 Topic Index Contact Info EEF S - earc . hi Ham X Home - Safety i; Claims lk Insurance Workplace Rights Trades Et Licensing ......... .... Find a Law or Rule'; Get a Form or Publication Look Up a Contractor, Electrician or Plumber General/Specialty Contractor A business registered as a construction contractor with LEtI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. . .......... --- .... . ..... ..... . .......... License Information License MCKIN**372NO Licensee Name MCKINSTRY CO Licensee Type CONSTRUCTION CONTRACTOR UBI 179012657 Verify Workers Comp Premium Status Ind. Ins. Account Id Business Type CORPORATION Address 1 5005 3RD AVE S Address 2 PO BOX 24567 City SEATTLE County KING State WA Zip 981240567 Phone 2067623311 Status ACTIVE Specialty I GENERAL L Specialty 2 UNUSED Effective Date 8/20/1963 Expiration Date 1/2/2006 Suspend Date Separation Date Parent Company Previous License Next License Associated License Business Owner Information Z Z LU 3 00, co W Lu 3: -j P (0 tL W 0 U. a. LU 0* Z !- LU uj ; 5* . 0—, �a H-F W L U , u- O_ ill Z' co : F- Z https:Hfortress.wa.gov/lni/bbip/Detail.aspx?License=MCKIN**372NO 07/22/2005 PRANIN6 INDEX A -O DOVER SHEET A -I ARCHITECTURAL GON5TR11GTION PLAN 5TRUCiTIAi& :i-I NOT USED !'EGNAIdIGN. M -I NOT USED ELEC+1RICAL (ELECTRICAL WORK UNDER SEPARATE PERMIT) E -I NOT USED I CONSTRUCTION PHASING NOT APPL I GABLE l irl .I IP Q $uiifliN6 MAP dEkok �� msoN villa of of we* � IN" ��„ v/ "a" � ^o'er /M� aid fwN af01r10r^ .a I've, .� f�Vl!!W apps is to oval s and cm mom ow" Of dOES floc a1�flafM ft vioww d any adopaed °ode a WW d ew Meld Dopy and --- Is adano� ok'i00000000000 Dom: � � 1 � 1.`11 • MICROSOFT NETWORK COLO #4 COLD 4 EXPANSION TRAY PACKAGE INTERNET SERVICE EXCHANGE FACILITY 000 ISX - SE I INTERGATE EAST 3433 SOUTH 120th PLACE TUKWILA, WA 98168 PROJECT DATA PROJECT NAME: TENANT IMPROVEMENT FOR MICROSOFT, ABOVE NET AT INTER6ATE EAST 3433 SOUTH I20th PLACE T'tJKWILA, WA 4b168 ZONING: MIG /H MANUFAGTUR I N6 INDUSTRIAL CENTER/HEAVY PARCEL 1029044069 S I TE AREA I"f3,Ab5 SF SEISMIC CLASSIFICA71ONB: SEISMIC USE GROUP: II NOLUNTERY UPGRADE) SEISMIC DESIGN CATEGORY: D SITE GLA55: D ONE SECOND PERIOD 51: 45.5A5 SHORT PERIOD 55: 140.6% (FORMERLY uBG ZONE 3) 17FmelcvN CODES: 2008 EDITIONS OF: INTERNATIONAL BUILDING GORE INTERNATIONAL FIRE CODE INTERNATIONAL MECHANICAL GODS UNIFORM PLUMBIN6 GORE 200 EDITION OF NNTIONAt. ELECTRIC GORE 2009 WASFI. STATE ENERGY GORE NFPA 75 ELECTRONIC COMPUTER/DATA PROGE551N6 BUIL=�ING flATA ADDRE55: AeovE NET 3433 SOUTH I20th PLACE TUKWILA,WA 48186 5LI�&- OWNER INTERNATIONAL GATEWAY EAST, LLG 1201 TUKY'IILA INTERNATIONAL BLVD., 4th FLOOR SEATTLE, WA5HIN6TON q816b -512I TEL: (206) 281 -8'100 CONTACT: JOHN SABEY 15UILidIN& AREA TOTAL FLOOR: 116,019 5F NORTH SERVICE YARD: 6059 5F SOUTH SERVICE YARD: 0 1,535 5F CONSTRUCTION TYPE VA (FORMALLY V - I HR) FULLY Sf'RINKLERED I -STORY low CCCLJFANC'*io' B- BU51NE55 TELEPHONE EXCHANGE (FORMALLY UHG FI FAG70RY INDUSTRIAL) PARKING ENTIRE FACILITY ANTICIPATES HOUSING A MAXIMUM OF 30 EMPLOYEES AND 30 VISITORS. NUMBER OF PARKING SPADES 15 60. (REFER TO A80VENET LETTER DATED 5/5/00) M i v • PROJECT STATEMENT — TENANT IMPROVEMENTS TO AN EXISTING TELECOMMUNICATION FACILITY (ELECTRONIC SAITCH&EAR). WORK CONSISTS OF: W m I. INSTALLATION OF GABLE TRAYS (TO MATCH EXI5TIN6) — O 10 d 2. PROJECT T AREA: 1600 SF. •PRLL, N • as IY d 5TRUCTURAL CALC5 PREPARED AND APPROVED UNDER PERMIT t NO. 005 - 76 (CABINETS) AND 005 - 11 (TRAYS) SHALL APPLY TO 1,245 crAR /GNU Z THE INSTALLATION DETAILS FOR THIS PROJECT. M OUNTAIN /IE^ O Q p GA, G- I.O- T3 -I-�31 Z c .. co W o ~ LEGAL. =)E5CRIPTION FA\ (650 555 -Ig�� w o a LOT 2 OF SHORT PLAT NO. 785018, ACCORDING TO THE SHORT PLAT 105 EAST PINE STREET REC40RDW UNDER KI N6 COUNTY RECORD IN6 NO. 860524Og5Ot M I S SOUL A r TOGETHER WITH THAT PORTION OF THE NORTH HALF OF VACATED MONTANA, 5gaC2 0 SOUTH 124th STREET LYIN& EAST OF THE SOUTHERLY PRODUCTION (40(o) OF THE Ye5T LINE OF SAID LOT 2 OF THE SHORT PLAT AND F A \ : 1'406) Ye5TERLY OF A LINE BE I N6 50 FEET NEST OF THE PARALLEL W 1 TH THE NORTHERLY EXTENSION OF THE CENTERLINE OF 55th AVENUE o SOUTH AS LOCATED BY THE PLAT OF RIVERTONt AND TOGETHER a WITH THAT PORTION OF VACATED 35th AVENUE SOUTH ADJO I N I N& AS VACATED UNDER CITY OF TUKWILA ORDINANCE NO. 1512, RECORDED N UNDER RECORD I N6 NO. gOOq l AH I CH, UPON VACATION, ATTACHES TO ' SAID PROPERTY BY OPERATION OF LAYVt SITUATE IN THE CITY OF = TUKWILA, COUNTY OF KIN&, STATE OF W045HIN6TON. 0 0 m 6ENERAL (UNLESS OTHERW 15E NOTED) I. THESE DRAWI1465 YORE PREPARED IN ACCORDANCE WITH THE 2003 INTERNATIONAL BUILDING CODE (IBC) 2. VERIFY EXISTING (E) CONDITIONS ON 51TE AND REVIEW MODIFICATIONS REQUIRED TO SUIT (EJ CONDITIONS PRIOR TO FABRICATION AND INSTALLATION. INCLUDING UNDERSIDE UTILITY LOCATIONS. 5 . TYPE OF LOCK OR LATCH, EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE W 1 THOUT THE USE OF KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. DOOR HARDWARE SHALL BE H.G. ACCESSIBLE LEVER TYPE UNO. TELCO EQUIPMENT ROOMS NEED NOT BE H.G. ACCESSIBLE. 1 4. EXITS 5HALL BE ILLUMINATED AT ANY TIME THE BU I LD I N& 15 OC.CUP I ED WITH LIGHT HAV ! NG INTENSITY OF NOT LE55 THAN I FOOTCANDLE AT FLOOR LEVEL.. f. 5. WHERE REQUIRED, EXIT 5I &N5 SHALL BE INSTALLED AT REQUIRED EXIT DOORYVAYS AND WHERE OTHERA15E NECE55ARY TO CLEARLY INDICATE THE DIRECTION OF EGRE55 WHEN THE EXIT SERVES AN EXIT LOAD REQUIRING TWO OR MORE EXITS. ; 6. COMPLY WITH SPECIAL INSPECTION REQUIREMENTS OF SECTION 1'101 OF THE UNIFORM !BUILDING CODE AS APPLICABLE TO TH15 PROJECT. 0 7. ALL PARTITION DIMEN5;0145 ARE TO FACE OF STUD UNLE55 OTHERWI5E NOTED. 8. SEISMIC BRAG I N& AND ANGHORI N& OF EQUIPMENT SYSTEMS SHALL BE IN ACCORDANCE W 1 TH APPLICABLE SECTIONS OF THE UBC WITH THE EXCEPTION OF MECHANICAL EQUIPMENT AND D 1ST, WHICH SHALL COMPLY YV 1 TH 5MACNA GUI DEL I NE5 FOR SEISMIC RE5TRA I NT5 OF MECHANICAL UNITS. PROJECT TEAM OWNER: ABOVE NET 3455 120th PL TUKWILA, WA 4 18168 CONTACT: RON THOMPSON EMAIL: Ron.Thompsoneabove.net TEL: (206) q88 -8698 CELL: (206) 5 -4277 ARCH I 7EC7/57RUC7: 60RDON PRILL INC. 1245 PEAR AVE MOUNTAIN V I EA, GA 4 14045 TEL: (650) 555 -IggO FAX: (650) 355 -1°188 GONTAGT: BRIAN LA RY, A.I.A. E -MAIL bblawry®gpdinc.com TENANT: MICROSOFT CORPORATION ONE MICROSOFT WAY REDMOND, WASHINGTON 48052 TEL: (425) 706 -8665 CELL: (425) 766 -5q75 E -MAIL: lour(h®mlcrosoft.com CONTACT: Lourl Haycock SPECIALTY CONTR: MGK I NSTRY CO. 5005 5RD AVE. SOUTH SEATTLE, KA g8154 TEL: (206) 852 -8158 FAX: (206) 852 -8582 E-MAIL: DANHOO MCK I NSTRY .COM CONTACT: DANNY HORTON, PROJECT MANAGER 7,5 *4 1ZA I hA►ND I G A1T�p !� A1lK i NQr I J jChISTINO. 5 55 5 molrH , PLACE 7677 RE GISTE RED ARCHITECT RIAN Wily STALE Pm4jrGT STATZMENT. 1 f NO RXTMIOR MORK IS f�o*osea P on Tmis -� C^sT M��I rwRY I�I�Q.lGT SITE MA I ou) J a 0 u vW o� a W W J Who 0 Z Z V IL •~ COOK + ` . s / � � o s ? • 3 11 3th St wZ O s 1 tf A J ~� • ` •�► A 4. > 8 tip+ F" �r S � �► y w 4 > SI tau 91 fry ►u► 1 OQ N � S t.'. r. M z PROJECT °� �. �' ' `o LOCATION -�. :,a,wst�, ire sr a g 1 331d ��a .AM • •.r,• ... C N." 1, �.. L,. ►.... p. I N I T1 MAP l irl .I IP Q $uiifliN6 MAP dEkok �� msoN villa of of we* � IN" ��„ v/ "a" � ^o'er /M� aid fwN af01r10r^ .a I've, .� f�Vl!!W apps is to oval s and cm mom ow" Of dOES floc a1�flafM ft vioww d any adopaed °ode a WW d ew Meld Dopy and --- Is adano� ok'i00000000000 Dom: � � 1 � 1.`11 • MICROSOFT NETWORK COLO #4 COLD 4 EXPANSION TRAY PACKAGE INTERNET SERVICE EXCHANGE FACILITY 000 ISX - SE I INTERGATE EAST 3433 SOUTH 120th PLACE TUKWILA, WA 98168 PROJECT DATA PROJECT NAME: TENANT IMPROVEMENT FOR MICROSOFT, ABOVE NET AT INTER6ATE EAST 3433 SOUTH I20th PLACE T'tJKWILA, WA 4b168 ZONING: MIG /H MANUFAGTUR I N6 INDUSTRIAL CENTER/HEAVY PARCEL 1029044069 S I TE AREA I"f3,Ab5 SF SEISMIC CLASSIFICA71ONB: SEISMIC USE GROUP: II NOLUNTERY UPGRADE) SEISMIC DESIGN CATEGORY: D SITE GLA55: D ONE SECOND PERIOD 51: 45.5A5 SHORT PERIOD 55: 140.6% (FORMERLY uBG ZONE 3) 17FmelcvN CODES: 2008 EDITIONS OF: INTERNATIONAL BUILDING GORE INTERNATIONAL FIRE CODE INTERNATIONAL MECHANICAL GODS UNIFORM PLUMBIN6 GORE 200 EDITION OF NNTIONAt. ELECTRIC GORE 2009 WASFI. STATE ENERGY GORE NFPA 75 ELECTRONIC COMPUTER/DATA PROGE551N6 BUIL=�ING flATA ADDRE55: AeovE NET 3433 SOUTH I20th PLACE TUKWILA,WA 48186 5LI�&- OWNER INTERNATIONAL GATEWAY EAST, LLG 1201 TUKY'IILA INTERNATIONAL BLVD., 4th FLOOR SEATTLE, WA5HIN6TON q816b -512I TEL: (206) 281 -8'100 CONTACT: JOHN SABEY 15UILidIN& AREA TOTAL FLOOR: 116,019 5F NORTH SERVICE YARD: 6059 5F SOUTH SERVICE YARD: 0 1,535 5F CONSTRUCTION TYPE VA (FORMALLY V - I HR) FULLY Sf'RINKLERED I -STORY low CCCLJFANC'*io' B- BU51NE55 TELEPHONE EXCHANGE (FORMALLY UHG FI FAG70RY INDUSTRIAL) PARKING ENTIRE FACILITY ANTICIPATES HOUSING A MAXIMUM OF 30 EMPLOYEES AND 30 VISITORS. NUMBER OF PARKING SPADES 15 60. (REFER TO A80VENET LETTER DATED 5/5/00) M i v • PROJECT STATEMENT — TENANT IMPROVEMENTS TO AN EXISTING TELECOMMUNICATION FACILITY (ELECTRONIC SAITCH&EAR). WORK CONSISTS OF: W m I. INSTALLATION OF GABLE TRAYS (TO MATCH EXI5TIN6) — O 10 d 2. PROJECT T AREA: 1600 SF. •PRLL, N • as IY d 5TRUCTURAL CALC5 PREPARED AND APPROVED UNDER PERMIT t NO. 005 - 76 (CABINETS) AND 005 - 11 (TRAYS) SHALL APPLY TO 1,245 crAR /GNU Z THE INSTALLATION DETAILS FOR THIS PROJECT. M OUNTAIN /IE^ O Q p GA, G- I.O- T3 -I-�31 Z c .. co W o ~ LEGAL. =)E5CRIPTION FA\ (650 555 -Ig�� w o a LOT 2 OF SHORT PLAT NO. 785018, ACCORDING TO THE SHORT PLAT 105 EAST PINE STREET REC40RDW UNDER KI N6 COUNTY RECORD IN6 NO. 860524Og5Ot M I S SOUL A r TOGETHER WITH THAT PORTION OF THE NORTH HALF OF VACATED MONTANA, 5gaC2 0 SOUTH 124th STREET LYIN& EAST OF THE SOUTHERLY PRODUCTION (40(o) OF THE Ye5T LINE OF SAID LOT 2 OF THE SHORT PLAT AND F A \ : 1'406) Ye5TERLY OF A LINE BE I N6 50 FEET NEST OF THE PARALLEL W 1 TH THE NORTHERLY EXTENSION OF THE CENTERLINE OF 55th AVENUE o SOUTH AS LOCATED BY THE PLAT OF RIVERTONt AND TOGETHER a WITH THAT PORTION OF VACATED 35th AVENUE SOUTH ADJO I N I N& AS VACATED UNDER CITY OF TUKWILA ORDINANCE NO. 1512, RECORDED N UNDER RECORD I N6 NO. gOOq l AH I CH, UPON VACATION, ATTACHES TO ' SAID PROPERTY BY OPERATION OF LAYVt SITUATE IN THE CITY OF = TUKWILA, COUNTY OF KIN&, STATE OF W045HIN6TON. 0 0 m 6ENERAL (UNLESS OTHERW 15E NOTED) I. THESE DRAWI1465 YORE PREPARED IN ACCORDANCE WITH THE 2003 INTERNATIONAL BUILDING CODE (IBC) 2. VERIFY EXISTING (E) CONDITIONS ON 51TE AND REVIEW MODIFICATIONS REQUIRED TO SUIT (EJ CONDITIONS PRIOR TO FABRICATION AND INSTALLATION. INCLUDING UNDERSIDE UTILITY LOCATIONS. 5 . TYPE OF LOCK OR LATCH, EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE W 1 THOUT THE USE OF KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. DOOR HARDWARE SHALL BE H.G. ACCESSIBLE LEVER TYPE UNO. TELCO EQUIPMENT ROOMS NEED NOT BE H.G. ACCESSIBLE. 1 4. EXITS 5HALL BE ILLUMINATED AT ANY TIME THE BU I LD I N& 15 OC.CUP I ED WITH LIGHT HAV ! NG INTENSITY OF NOT LE55 THAN I FOOTCANDLE AT FLOOR LEVEL.. f. 5. WHERE REQUIRED, EXIT 5I &N5 SHALL BE INSTALLED AT REQUIRED EXIT DOORYVAYS AND WHERE OTHERA15E NECE55ARY TO CLEARLY INDICATE THE DIRECTION OF EGRE55 WHEN THE EXIT SERVES AN EXIT LOAD REQUIRING TWO OR MORE EXITS. ; 6. COMPLY WITH SPECIAL INSPECTION REQUIREMENTS OF SECTION 1'101 OF THE UNIFORM !BUILDING CODE AS APPLICABLE TO TH15 PROJECT. 0 7. ALL PARTITION DIMEN5;0145 ARE TO FACE OF STUD UNLE55 OTHERWI5E NOTED. 8. SEISMIC BRAG I N& AND ANGHORI N& OF EQUIPMENT SYSTEMS SHALL BE IN ACCORDANCE W 1 TH APPLICABLE SECTIONS OF THE UBC WITH THE EXCEPTION OF MECHANICAL EQUIPMENT AND D 1ST, WHICH SHALL COMPLY YV 1 TH 5MACNA GUI DEL I NE5 FOR SEISMIC RE5TRA I NT5 OF MECHANICAL UNITS. PROJECT TEAM OWNER: ABOVE NET 3455 120th PL TUKWILA, WA 4 18168 CONTACT: RON THOMPSON EMAIL: Ron.Thompsoneabove.net TEL: (206) q88 -8698 CELL: (206) 5 -4277 ARCH I 7EC7/57RUC7: 60RDON PRILL INC. 1245 PEAR AVE MOUNTAIN V I EA, GA 4 14045 TEL: (650) 555 -IggO FAX: (650) 355 -1°188 GONTAGT: BRIAN LA RY, A.I.A. E -MAIL bblawry®gpdinc.com TENANT: MICROSOFT CORPORATION ONE MICROSOFT WAY REDMOND, WASHINGTON 48052 TEL: (425) 706 -8665 CELL: (425) 766 -5q75 E -MAIL: lour(h®mlcrosoft.com CONTACT: Lourl Haycock SPECIALTY CONTR: MGK I NSTRY CO. 5005 5RD AVE. SOUTH SEATTLE, KA g8154 TEL: (206) 852 -8158 FAX: (206) 852 -8582 E-MAIL: DANHOO MCK I NSTRY .COM CONTACT: DANNY HORTON, PROJECT MANAGER 7,5 *4 1ZA I hA►ND I G A1T�p !� A1lK i NQr I J jChISTINO. 5 55 5 molrH , PLACE 7677 RE GISTE RED ARCHITECT RIAN Wily STALE Pm4jrGT STATZMENT. 1 f NO RXTMIOR MORK IS f�o*osea P on Tmis -� C^sT M��I rwRY I�I�Q.lGT SITE MA I ou) J a 0 u vW o� a W W J Who 0 Z Z V IL 9 r9 Li M Wes" 0 J Y >0 � 0 I—) W L he Q _zm �c � v W �n "3 1 N A -0 i � - � � .. .. . • v. ..fin ••V.�Y.t� ...�.I1! ✓' •�.' «n ►'wi. �� LL�.. �Y:�. If T .. f .Ir . , . • , .. ., ARE of ^0RK - H V) W wZ O I C w CD " w OQ N � z J LL- O r� CIS r� Y O mot - F- — Z W V 9 r9 Li M Wes" 0 J Y >0 � 0 I—) W L he Q _zm �c � v W �n "3 1 N A -0 i � - � � .. .. . • v. ..fin ••V.�Y.t� ...�.I1! ✓' •�.' «n ►'wi. �� LL�.. �Y:�. If T .. f .Ir . , . • , .. ., ARE of ^0RK - • G I { H 49j_'*wA.'L' IL W" u'.4a&i *AASLA; _40 A5 * '7 CU"JLATI\/E OCCUPANT M) RATED LOAD FOR ROOM, OR 21.6 CORRIDOR AT THIS DOOR. y OFFICE 9 604 517/1100 C4 L 6.0 OCCUPANTS A EXISTING ROOMS (NIC) 7 - - _ — �� ..,. x _j % L J ri Ll F_' _4 TELCO EOUIP 1182 5F/300 6.6 OCCUPANTS , o _ 1 I l p 6, L n z t I G y H 1. 1j. 14 42 1 ... -.. _... _ ...... ,� L "T 9 �________ _._ I I__j_ L__ il I I Li F _ _ -_ 7 EXISTING RACK5 v 5 A. z TELCO EGUIP 110814 5F/500 56.2 OCCUPANTS ELECT EQUIP (be) 5F/500 A OCCUPANTS 0 ­4 . 4 F _ L—A A t (r:) RATED 2 451 CUMULATIVE OCCUPANT LOAD FOR ROOM, OR 21.41 AT THIS DOOR 1 ARCHITECTURAL FLOOR PLAN Al SCALE: 3/32 1 0 6 5 -4 f 1� 5Co,0FE OF WORK A. INSTALL CABINET MOUNTED AND UNDERFLOOR TRAYS TO MATCH EXISTING INSTALLATIONS. 15. OWNER PROVIDED CABINETS INSTALLED UNDER SEPARATE PERMIT. QTY: 40 CA51NET5, AND 4 RACKS C. CABINET/RACK ELECTRICAL WORK UNDER SEPARATE DE516N/BUILD PERMIT. GENERAL NOTES A. STRUCTURAL CALC5 PREPARED AND APPROVED UNDER PERMIT NO. 005-16 (CABINETS) AND 005-11 (TRAYS) SHALL APPLY TO THE INSTALLATION DETAILS FOR THIS PROJECT. B. TYPE OF LOCK OR LATCH, EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE Y41THOUT THE USE OF KEY OR ANY SPECIAL KNOM-ED6E OR EFFORT. DOOR HARDWARE SHALL BE H.C. ACCESSIBLE LEVER TYPE UNO. AM 001 ID ON*PRLL, IC 1."b'. 4 5 FE A A / E: N vE MOUNTAIN ,IIEV4 CA, 4-14045-1431 z (650 FA\ (650) 105 EA5T FINE STREET MIS-BOULA MONTANA (406) 121-5c`156 F AQ: j G(v) - 7. - 0 1 - P, 7 (o C) C. WORK NOTED AS "FUTURE" 15 5HOYIN FOR INFO ONLY, AND WILL C) F__ BE PERM ITED SEPARATLY. cl- w C.) V. ALL CONSTRUCTION ACTIVITIES SHALL COMPLY WITH MICROSOFT'S CONSTRUCTION U) REOUIREMENTS FOR CONSTRUCTION WORK WITHIN ACTIVE COLO AREAS. w c c z L E. MAINTAIN A PHYSICAL SEPARATION BETWEEN THE FLOOR SUPPORT SYSTEM (TO z INCLUDE CABLE TRAYS) AND THE ROOF SUPPORTED 5Y97EM OF AT LEAST 5" 10 HORIZONTAL. ro LEGEND : EX1571N& ACCE55 FLOOR MOTES LINE TYPES MANUFACTURER: MAXCESS TECHNOL061E5, INC, SYSTEM- BOLTED STRINGER VV BOLTED CONCRETE CORE TILES (N) NEW TILE- RYV,400 YV NEVAMAR ST-6-1 CPF;ZAY STARLITE (E) EXISTING 'PERF TILE. SP200 SIZE: 24x24 ---------- (D) DEMO -HEI&HT: 50" ABOVE SLAB ON GRADE ATTACHMENT: MASTIC AND (2) Y A.B. ALTERNATI N6 DIAGONAL UNIFORM LOAD: 500 P5F CONCENTRATED LOAD: 2000 L55 ROLLING LOAD. 1500 LBS. EQUIPMENT LATERAL LOADS: FLOOR ORIGINALLY DE516NED TO ACCOMMODATE CABINET/RACK LATERAL LOADS SHEET NOTES 0 OWNER PROVIDED RACKS /CABINETS, INSTALLED UNDER A SEPARATE PERMIT. NEW 24" FLEX TRAY MOUNTED TO TOP OF CABINET5, WITH 90 DE& TRAN515TION -0 51DE OF CABINET. UNDERFLOOR TRAYS (NOT 5HONN) WILL CONSIST OF EXTENDING (E) 20" FLEX TRAY TO NEW CABINETS. ALL UNDERFLOOR TRAY AND CABLE SHALL BE PLENUM RATED. 0 NEW 24" TROUGH MOUNTED TO TOP OF RACKS. r C`� 11 1i L ll A L 4-- T T si ­7 j J A 3 11 1 t ` I ,r yI � �- i ,,� :, , - r ; A.L AJ 2 r . 2 CABLE TRAY Al SCALE: 3/32 1 -0" RE���p�paVC� ovk 5 700 . --r-� p,� Tukwi 51 ON OIN ��5 20� Q?)pq .Zb % J* 1 5 ft LA P ERUr r 1 7677 REGISTEpe "I s ARCHITECT STA,l,E IAIY B. smfva• I = 040 O W ma mn 0 W mi o z 0 z u ac IL < L LLJ LJ u 0 L < _j 0 < Ln cj CL C-5 wm z m 0 I LL_ o z < U) 0 d J an C) IL z ul z Lai Z J �Q v¢ Ln AID C) C. WORK NOTED AS "FUTURE" 15 5HOYIN FOR INFO ONLY, AND WILL C) F__ BE PERM ITED SEPARATLY. cl- w C.) V. ALL CONSTRUCTION ACTIVITIES SHALL COMPLY WITH MICROSOFT'S CONSTRUCTION U) REOUIREMENTS FOR CONSTRUCTION WORK WITHIN ACTIVE COLO AREAS. w c c z L E. MAINTAIN A PHYSICAL SEPARATION BETWEEN THE FLOOR SUPPORT SYSTEM (TO z INCLUDE CABLE TRAYS) AND THE ROOF SUPPORTED 5Y97EM OF AT LEAST 5" 10 HORIZONTAL. ro LEGEND : EX1571N& ACCE55 FLOOR MOTES LINE TYPES MANUFACTURER: MAXCESS TECHNOL061E5, INC, SYSTEM- BOLTED STRINGER VV BOLTED CONCRETE CORE TILES (N) NEW TILE- RYV,400 YV NEVAMAR ST-6-1 CPF;ZAY STARLITE (E) EXISTING 'PERF TILE. SP200 SIZE: 24x24 ---------- (D) DEMO -HEI&HT: 50" ABOVE SLAB ON GRADE ATTACHMENT: MASTIC AND (2) Y A.B. ALTERNATI N6 DIAGONAL UNIFORM LOAD: 500 P5F CONCENTRATED LOAD: 2000 L55 ROLLING LOAD. 1500 LBS. EQUIPMENT LATERAL LOADS: FLOOR ORIGINALLY DE516NED TO ACCOMMODATE CABINET/RACK LATERAL LOADS SHEET NOTES 0 OWNER PROVIDED RACKS /CABINETS, INSTALLED UNDER A SEPARATE PERMIT. NEW 24" FLEX TRAY MOUNTED TO TOP OF CABINET5, WITH 90 DE& TRAN515TION -0 51DE OF CABINET. UNDERFLOOR TRAYS (NOT 5HONN) WILL CONSIST OF EXTENDING (E) 20" FLEX TRAY TO NEW CABINETS. ALL UNDERFLOOR TRAY AND CABLE SHALL BE PLENUM RATED. 0 NEW 24" TROUGH MOUNTED TO TOP OF RACKS. r C`� 11 1i L ll A L 4-- T T si ­7 j J A 3 11 1 t ` I ,r yI � �- i ,,� :, , - r ; A.L AJ 2 r . 2 CABLE TRAY Al SCALE: 3/32 1 -0" RE���p�paVC� ovk 5 700 . --r-� p,� Tukwi 51 ON OIN ��5 20� Q?)pq .Zb % J* 1 5 ft LA P ERUr r 1 7677 REGISTEpe "I s ARCHITECT STA,l,E IAIY B. smfva• I = 040 O W ma mn 0 W mi o z 0 z u ac IL U) Wm 00 JU 0 42 ug L �W� C) 94 z x) " t' J �� Uzi a� A - 1 < L LLJ LJ u 0 L < _j 0 < 0 L'j V) LL_ o U) 0 Qf r4 an C) z ul U) Wm 00 JU 0 42 ug L �W� C) 94 z x) " t' J �� Uzi a� A - 1