Loading...
HomeMy WebLinkAboutPermit D05-211 - 700 ANDOVER PARK WEST - REROOFVACANT - ANDOVER PK W 700 ANDOVER PK W EXPIRED DOS -211 Z: w JU U O; W w; W I' J F.: W 0. g J' tL Q': _ Z H. O` Z �. ui w U0 OH' W. H U - O. Z' W N; OF-', Z City oz \ Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: ci.tukwila.wa.us DEVELOPMENT PERMIT Steven M. Mullet, Mayor Steve Lancaster, Director Parcel No.: 2623049124 Permit Number DOS -211 Address: 700 ANDOVER PK W TUKW Issue Date: 07/12/2005 Suite No: Permit Expires On: 01/08/2006 Tenant: Name: VACANT - ANDOVER PK W Address: 700 ANDOVER PK W, TUKWILA WA Owner: Name: VON ELTZ - RUBENACH ROBIN K F Phone: Address: C/O METZLER REALTY ADVISORS, 700 FIFTH AVE #6175 Contact Person: Name: CHUCK MAHLUM Phone: 206 784 -8414 Address: 4910 15 AV NW, SEATTLE WA Contractor: Name: HAIGHT ROOFING COMPANY INC. Phone: 206 784 -8414 Address: 4910 15TH AVE NW, SEATTLE, WA Contractor License No: HAIGHRC269QK Expiration Date: 05/11/2006 DESCRIPTION OF WORK: REMOVE EXISTING BUR AND REPLACE WITH NEW BUR. REMOVING EXISTING BUILT -UP CAP SHEET ROOF TO THE EXISTING PLYWOOD DECK. NAIL RED ROSIN SHEET AND MECHANICALLY ATTACH NEW COVER BOARD. TWO PLIES OF MODIFIED TYPE 6 SHEETS WILL THEN BE SET IN MOPPINGS OF HOT ASPHALT, FOLLOWED BY A MODIFIED CAP SHEET ALSO SET IN HOT ASPHALT. Value of Construction: $174,809.00 Fees Collected: $2,896.09 Type of Fire Protection: SPRINKLERS International Building Code Edition: 2003 Type of Construction: Occupancy per IBC: 0019 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Flood Control Zone: N Hauling: N Land Altering: N Landscape Irrigation: N Moving Oversize Load: N Sanitary Side Sewer: N Sewer Main Extension: N Storm Drainage: N Street Use: N Number: 0 Start Time: Volumes: Cut 0 C.Y. Start Time: Private: Profit: N Size (Inches): 0 End Time: Fill 0 c.y. End Time: Public: Non - Profit: N Z iE Z it Q � JU 00, N a w= J CO W w U. CO) D = �.. w. Z 1 2 w Uj U CO 0 H w � LL O. w Z co Z Water Main Extension: Water Meter: City o Tukwila Steven M. Mullet, Mayor Department of Commuttity Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: ci.tu/nvila.wa.us N Private: N Public: Steve Lancaster, Director I 1 City o. Tukwila Departn :e► :t of Commu►►ity Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: ci.tukwila.wa.us Permit Number: Issue Date: Permit Expires On: Steven M. Mullet, Mayor Steve Lancaster, Director DOS -211 07/12/2005 01/08/2006 I I Permit Center Authorized Signature: / ' Y,�c�P l��,Gri'� Date: 07 � -/0 i I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. i - a The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws 1 regulating constructio r the performance of work. I am authorized to sign and obtain this development permit. i Signature: /L Date: Print Name: L I This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is j suspended or abandoned for a period of 180 days from the last inspection. Z W JU U O (D o VU J cl) LL W O• LL U. ¢. Ca = U Z r~ O Z f--' W �; U � O� W UJ LL O ui Z U co , H =� O� Z doc: IBC- Permit D05 -211 Printed: 07 -12 -2005 .� �g City of Tukwila face Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 PERMIT CONDITIONS Parcel No.: 2623049124 Address: 700 ANDOVER PK W TUKW Suite No: Tenant: VACANT - ANDOVER PK W Permit Number DOS -211 Status: ISSUED Applied Date: 06/21/2005 Issue Date: 07/12/2005 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: Prior to final inspection a written statement from the roofing contractor shall be required. The statement shall confirm the fire classification of the roof assembly that was installed. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ** *FIRE DEPARTMENT CONDITIONS * ** 10: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 11: An operational permit is required to conduct hot work. (IFC 105.6.24, Chapter 26) 12: An operational permit is required to erect or operate a tent or air - supported temporary membrane structure having an area in excess of 200 square feet, or a canopy in excess of 400 square feet, except for structures used exclusively for camping. (IFC 105.6.44, Chapter 24) 13: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. 14: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Z Z w _3U 00 Co J N LL wO �a_J LL ¢ co = F w z P H O Z i~ W U co ' o f- wW u. O w Z U= O ~. Z doc: Conditions D05 -211 Printed: 07 -12 -2005 � X Ci of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 15: These plans were reviewed by Inspector 512. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. * *continued on next page ** I i i i i Y �g City of Tukwila 1906 Department of Community Development / 6300 Southcenter BL, Suite 100 Tukwila, WA 98188 (206) 431-3670 doc: Conditions D05-211 Printed: 07-12-2005 I +u. w CITY OF T UKWI LA Community Development' �iartment Public Works Department Permit Center 1905 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 Building Perm ­ To. Mechanical Permit No. Public Works Permit No: Project No. For office. use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** .: . 1 SITE- LOCATION: King Co Assessor's Tax No.: _ �o.2.�G Site Address: 700 -768 Andover Park West Suite Number: Floor: Tenant Name: N/A W1CA N T New Tenant: ❑ .... Yes []..No Property Owners Name Metzler Reality Advisors, Inc. Mailing Address: 700 - 5th Avenue, Suite 6175 Seattl a Washington 98104 City State Zip CONTACT PERSON Name: Chuck Mahl um Day Telephone: 206 784 -8414 Mailing Address 4910 - 15th Avenue Northwest Seattle, Washington 981 City State Zip E -Mail Address: N/A Fax Number: 206- 784 -1058 GENERAL .CONTRACTOR INFORMATION = (Mechanical Contractor information on back.page). Company Name Haight Roofing Company, Inc. Mailing Address 4910 - 15th Avenue Northwest Seattle Washington 98107 City Slate Zip Contact Person: Chuck Mahl um Day Telephone: 206- 784 -8414 E -Mail Address: N/A Fax Number: 206- 784 -1058 Contractor Registration Number: HA IG HR C269QK Expiration Date: 5/11/2006 * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** ARCHITECT. OF RECORD = All plans must be wet stamped.by Architect of Record Company Name: N/A Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: ENGINEER_ OF RECORD All plans must. be wet stamped by Engineer of Record Company Name: N/A Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: q.\ \permits pluslicc changesl{xnnit application (7.2004) Revised: 6.8.05 hh Page 1 Z ;H Z �W aa J UO Cl) C0 J � C0 LL WO LL Q N D = d F - w Z r^ z� W W U� ON OH Ww u. O Z W U= O Z BUtLDING::P'ERMIT >INFORMA`TION 206 -431- 3670: ' Valuation of Project (contractor's bid price): $ 174,809.00 Existing Building Valuation: $ Scope of Work (please provide detailed information): Remove existing Bur and replace with new Bur Will there be new rack storage? ❑ ..Yes [n.. No If "yes ", see Handout No. for requirements. Provide.All Building Areas in Square Footage Below PLANNING DIVISION: Single - family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ ....Yes ❑ ..No If "yes ", explain: FIRE PROTECTIONIHAZARDOUS MATERIALS: ®.. Sprinklers ❑..Automatic Fire Alarm ❑..None ❑ . Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ .. Yes ®..No If "yes ", attach list ojmaterials and storage locations on a separate 8 -112 x I I paper indicating quantities and Material Safety Data Sheets. +\ \permits plus\icc changes\permit application (7 -2004) Revbed, 6.8.05 Page 2 bb Z Z. �W 0 UO Cl) C3 C0 W J NU_ WO 9� WQ N� = F. W ' Z H I— O W l` � = p U O CO) �H W H LL O W Z CO) Z Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC I` Floor 35,900 2 nd Floor :. 3` d Floor Floors thru Basement Accessory Structure* ' Attached Garage Detached. Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single - family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ ....Yes ❑ ..No If "yes ", explain: FIRE PROTECTIONIHAZARDOUS MATERIALS: ®.. Sprinklers ❑..Automatic Fire Alarm ❑..None ❑ . Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ .. Yes ®..No If "yes ", attach list ojmaterials and storage locations on a separate 8 -112 x I I paper indicating quantities and Material Safety Data Sheets. +\ \permits plus\icc changes\permit application (7 -2004) Revbed, 6.8.05 Page 2 bb Z Z. �W 0 UO Cl) C3 C0 W J NU_ WO 9� WQ N� = F. W ' Z H I— O W l` � = p U O CO) �H W H LL O W Z CO) Z MECHANICAL PERMIT INFO 'IATION — 206.431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name N/A Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): Use: Residential: New .... ❑ Replacement..... ❑ Commercial: New .... ❑ Replacement..... ❑ Fuel Type Electric ..... ❑ Gas ­-n Other: Indicate type of mechanical work being installed and the quantity below: Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler/Compressor: Q Furnace <100K BTU Air Handling Unit >I0,000 Fire Damper 0 -3 HP /100,000 BTU CFM Furnace >100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected Thermostat 15 -30 HP /1,000,000 BTU to Single Duct Suspended/Wall /Floor Ventilation System Wood /Gas Stove 30 -50 HP /1,750,000 BTU Mounted Heater Appliance Vent Hood and Duct Water Heater 50+ HP /1,750,000 BTU Repair or Addition to Incinerator - Domestic Emergency Heat/Refrig/Cooling Generator System Air Handling Unit I Incinerator — Comm/Ind I Other Mechanical I <10,000 CFM Equipment PERMIT APPLICATION NOTES Applicable: to all permits in .this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER (}I�JAUTHORIZED AGENT: Signature: / � .�— Date. 6/20/05 Print Name: Chuck Mahl um Day Telephone: 206- 784 -8414 Mailing Address 4910 15th Avenue Northwest Seattle, Washington 98107 City State Zip Date Application Accepted: Date Application Expires: Staff In 1.2 - q.\ \permits plus\icc changes *rrnjt application (7.2004) Revised: 6 -8.05 YagC 4 bh Z Z a W W O _3 U 00 O W = H C0 W w 0 U- co O 2 C7 HW Z�- ' HO Z H w W U ON O I•— W W H �. LL 0 tit Z 0 O Z a d f City of Tukwila r� i 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 i i I Parcel No.: Address: Suite No: Applicant: i 2623049124 700 ANDOVER PK W TUKW VACANT - ANDOVER PK W Permit Number: Status: Applied Date: Issue Date: DOS -211 PENDING 06/21/2005 Receipt No.: R05 -00906 Initials: SKS User ID: 1165 RECEIPT t Payment Amount: 2 Payment Date: 06/21/2005 01:55 PM Balance: $0.00 i Payee: HAIGHT ROOFING COMPANY, INC. TRANSACTION LIST: .Type Method Description Amount ---- - - - - -- -- - - - - -- --------------------- - - - - -- ----- - - - - -- Payment Check 25014 2,896.09 ' ACCOUNT ITEM LIST: Description Account Code Current Pmts -------------------------- --- ---------- - - - - -- ------ - - - - -- BUILDING - NONRES 000/322.100 1,752.48 PLAN CHECK - NONRES 000/345.830 1,139.11 STATE BUILDING SURCHARGE 000/386.904 4.50 Total: 2,896.09 i i t 4313 06/22 971.0 TO T& 2B96.09 doc: Receipt Printed: 06 -21 -2005 Z - Z � U U0 w= J F- N U. W F } } }� J !L co) d. HW z rH 1- O Z W 5: CO3 O- 3 H. WW — 0 , Z tll UN O Z INSPECTION RECORD �GJ I •. � ti Retain a copy with permit INSPECTION NO. PE I N �5 ` CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Proj ct: Type IUPection: F] Approved per applicable codes. Corrections required prior to approval. COMMENTS: Add r ss: , � .. 12 Date Called: AJ 2f Special Instructions: ` O � ( �4 � Date Wanted: 3 m Reqgps2 1�t�. M Lv M Phone No: a F] Approved per applicable codes. Corrections required prior to approval. COMMENTS: i s �'.._ /N5 z /� 7 AJ 2f � Inspe or:. � [,.' Date- f 8.00 REI SPE ON FEE REQUIR . Prior to inspection, fee must be d at 6300 South enter Blvd., Suite 100. Call to sechedule reinspection. Receipt No.: I Date: 4 Z i� W UO 0 w: N W w O �_j U. F=- _ ?H H O Z I_ �p O CO), D F,_. W H U' U: 0 : ll! Z U� H� z "Since 1919" June 21, 2005 gcamms NO Ch R n geS Mail be IMdt to the scope 03 uroek tulthout prior approval of 'Gickwila Gu ldkq Dhdsion. NOTE: Revisions tvill require a new plan submittal and may include addkior W Dian review fLaes. City of Tukwila Department of Community Development 6300 Southcenter Blvd., Suite D Tukwila, WA 98188 RE: Narrative of re -roof project at 700 Andover Park West To whom it may concern: SEPARATE PERMIT REQUIRED FAR: W Mectwiral W Electrical ar Plumbing Be Gas Plping City Of Tukw;;a BUIL DING DIVISION The re -roof project for 700 Andover park West in Tukwila, Washington will consist of removing the existing built -up cap sheet roof to the existing plywood deck. After sweeping clean, we will nail a red rosin sheet and mechanically attach a new cover board. Two plies of modified Type 6 ply sheets will then be set in moppings of hot asphalt, followed by a modified cap sheet also set in hot asphalt. The building is currently insulated within the structure, and other than our cover board, no other insulation will be installed. Sincerely, Haight Roofing Company, Inc. :, 2 5 — z ) Permit Chuck Mahlum Project Manager R ev �o������E co�� q�� rt " �Q �C�( HAIGHT ROOFING COMPANY, INC. 4910 -15 Avenue NW Seattle, WA 98107 (206) 784 -8414 / Fax (206) 784 -1058 INDUSTRIAL /COMMERCIAL ROOFING, WATERPROOFING AND SHEET METAL WORK LIGHTWEIGHT INSULATING CONCRETE ROOF DECKS rw rev � � a e errors It P1 t� and om iss;atls. doourtxItts does not audwWcM- ED a CWe Or ordinance. ReF TUKWILA 19741d!7 of a4ppmed &W Q0ndbe is is admwle*o; 7 i � 00� BY PERMIT CENTER Dabs: �7 ' / 2' - oS-- Of 7U ���D II -z MEMBERS ROOFING CONTRACTORS ASSOC. OF WA /WESTERN STATES RCA / NRCA / BIAW / MASTER BUILDERS ASSOC. Washington State Contractors Registration Number HA- IG- HR- C269QK z W JU vo w= �U_ w O LLQ = a. �w Z� H O z I- 25 U O co ❑ I_ W W LLO W z U= O z 4 ' 'Jul ,Johns Manville Commercial /Industrial Roofing Systems UL External Fire Resistance (UL 790) Asphalt Adhered SBS Modified Bitumen Summary Chart f * Check Individual Construction Listing To Ensure Accuracy " Max. Slope Deck (Inch /Ft.) Insulation Base Ply Cap Rating Comments C (15/32) 1/2 E,FF,F,FG (1 +)GP,GPP,PP N/A DKF,DGF A (Optional) GB,DB,V,DP OG3,DL1 ;.. . DL2 C.(15/32) 1/2 E,F,FG* (1 +)GB,GB+ (1 +)GB,GB+ DKF,DGF A *Min 3/47, (Optional) PP,V PP,V,DB DL1,DL2 15 /16 "FG, 2 "E GP,GPP NC 1/2 E,FF,F,FG (1 +)GB,GB +,PP DKF,DGF A (Optional) V,OB,GP,GPP DL1,DL2 j C (15/32) 1 E,FF,F,FG (1 +)GB,DB,DP N/A DK,DP,DG A Gravel - (Optional) GPP DG3,DL1 Surface �. DL2 NC 3 E,FF,F,FG (1 +)GB,D6,DP N/A DK,DP,DG A Gravel (Optional) PP,GPP,GP,V DL1,DL2 Surface Legend: Deck: C= Combustible; ( ) =Min Thickness; NC= Non - Combustible Slope UL= Unlimited Insulation: E= E'NRG'Y2; F= Fesco; FF =Fesco Foam; RF =Retro -Fit; FG =FGR1 Base Sheet: PP= PermaPly 28; GB= GIasBase; GB += GIasBase Plus; V= Ventsulation; OB= DynaBase; OP= OynaPly ( Ply Sheet: GP= GIasPly IV; GPP = GIasPly Premier Cap Sheet DK= DynaKap; DKF= DynaKap FR; DG= DynaGlas; DGF= DynaGlas FR; DG3= DynaGlas30 FR; DL1= DynaLastic 180 FR; DL2= DynaLastic 250 FR; DMF= DynaMax FR; DC= DynaClad ' Coatings: TA= TopGard A; TB= TopGard B; FA= Fibrated Aluminum Roof Coating Notes: 1. Approvals for combustible decks automatically apply to non - combustible decks. } 2. Insulation is any thickness one or more layers unless otherwise stated. d6t J� Z Z` tY W . U O : . N 0 J � :Cj) u., WO L L = d ` f- LU Z Z O 5 , O �0 H. W W' H U U_ F.. O W Z U CO) Z 13 -4 l Johns Manville Three Ply Hot Mopped Modified Bitumen Mineral Surfaced Roofing System. For use over plywood or other nailable decks on inclines up to 3" per foot (250 mm /m). For Regions 1, 2 and 3 Materials per 100 sq. ft, (9.3 m of Roof Area Sheathing Paper: Wood board decks only 1 layer Felts; Base: GlasBase Plus, DynaBase, DynaPly, PermaPly 28 or DynaLastic 180 S 1 layer Intermediate: DynaBase, DynaPly, GlasPly Premier, GlasPly IV, PermaPly 28, DynaLastic 180 S or GlasBase Plus 1 layer Cap: 3CND — DynaKap or DynaKap FR 3FND — DynaGlas, DynaGlas FR or DynaGlas 30 FR* 3PND— DynaLastic 180, DynaLastic 180 FR, DynaLastic 250 o r DynaLastic 250 FR 1 layer 'DynaGlas 30 FR must be used in conjunction with DynaBase, DynaPly or DynaLastic 180 S only. Asphalt (Refer to Para. 7A.8): Trumbull or other JM Approved Asphalt Incline per foot Asphalt Total Weight Up to 'h" 190 °F, Type III, Steep 46 lbs. (21 kg) 'h" to 3" 220 °F, Type IV, Special Steep 46 lbs. (21 kg) Approximate installed weight: 165 - 360 lbs. (75. 163 kg), General This specification is for use over any type of approved structural deck (without insulation) which can receive and adequately retain nails or other mechanical fasteners that may be recommended by the deck manufacturer. Examples of these decks are wood, plywood, and approved oriented strand board (OSB). This specification is not for use directly over lightweight, insulating concrete decks. Design and installation of the deck and /or roof substrate must result in the roof draining freely, to outlets numerous enough and so located as to remove water promptly and completely. Areas where water ponds for more than 24 hours are unacceptable and will not be eligible for a JM Roofing System Guarantee. Note: All general instructions contained in the current JM Commercial/ Industrial Roofing Systems Manual shall be considered part of this specification. Flashings Flashing details can be found in the "Bituminous Flashings" section of the JM Commercial /Industrial Roofing Systems Manual. Application On roof decks with slopes up to 1 h" per foot (41.6 mm /m), the roofing felts and modified bitumen sheets may be installed either perpendicular or parallel to the roof incline. Over wood board decks, one ply of sheathing paper must be used under the base felt, next to the deck. Using one of the base felts listed, start with a piece 24" (610 mm) wide. The remaining felts are to be applied full width with 3" (76 mm) side and 4" (102 mm) end laps over the preceding sheets. Nail the laps at 9" (229 mm) centers, and down the longitudinal center of each felt place two rows of nails, with the rows spaced approximately 11" (279 mm) apart, and nails staggered on approximately 18" (457 mm) centers. Use nails or fasteners appropriate to the type of deck, with 1" (25 mm) minimum diameter caps, For additional fastener information, refer to the fastener Nailable Deck • Nails 4 Lap Sheathing Paper III Required) T. GlasBase Plus, ^� • • ♦ Approved JM DynaBase, SBS Cap Sheet DynaPly or PermaPly 28 or •— • DynaLastic 180 S I~ 18• --0- 3 Lap j A 3 Lap d' End Lap IT ° • — — • • to, 3PND) 1 N End laps m Staggered 1H1 Asphalt 3' Apart IMin.) • �'. . . 0yna8ase, DynaPly, GlasPly Premier, GlasPly IV, PermaPly 28, DynaLastic 180 S or GlasBase Plus 3CND /3FND/3PND data in the "Roof Decks" section of the current JM Commercial /Industrial Roofing Systems Manual. Roll an 18" (457 mm) wide piece of one of the intermediate felts listed into a full mopping of asphalt. The remaining felts are to be applied full width, in the same manner, with 3" (76 mm) side and 4" (102 mm) end laps over the preceding sheets. Apply a full width piece of one of the cap sheets listed into a full mopping of asphalt. Subsequent sheets are to be applied in the same manner, with 4" (102 mm) side and end laps over the preceding sheets (6" [152 mm] end laps for DynaLastic products). Apply all felts so that they are firmly and uniformly set, without voids, into the hot asphalt. Asphalt temperature should be at the Equiviscous Temperature (EVT), ±25 °F (t14 °C), at the point of application. All felt edges shall be well sealed. The asphalt shall be applied just before the felt, at a nominal rate of 23 lbs. per square (1.1 kg/ml). For modified bitumen sheets, the asphalt temperature shall be at a minimum of 400 °F (204 °C) when the sheet is set into it. This higher temperature maximizes the bonding of the modified bitumen sheet. Note: When using metric and English sized base and cap sheets in the same system, care must be taken to avoid lap over lap configurations. Base sheets and cap sheets with polyester reinforcement must be allowed to relax in an unrolled position prior to installation. For cold weather application techniques, refer to Paragraph 7A.24, Steep Slope Requirements Special procedures are required on inclines over I& per foot (41,6'rri �m Refer to Paragraph 7A.21. Surfacing 1IION��y�� \dv No additional surfacing is required. c n Asphalt Asphalt should meet the requirements of ASTM JM Guarantees require the use of Trum ull asphalt b nother JM Approved Asphalt. � _ % nY :k for { RS= 1 For an identical copy of this specification, 7 -20 Z h I 5 UO to o J CO U. WO U. Q Cl = uJ F'•' O Z F- �5 U� ON � E- ,uJ W H FU-- �O .. Z W U =, O Z Specification 3CND /3FND /3PND ILA, 0 't Z ; O r' 2 City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director 01 -02 -2007 CHUCK MAHLUM 4910 15 AV NW SEATTLE WA 98107 RE: Permit No. DOS -211 700 ANDOVER PK W TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such germit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned.. If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for additional periods not exceeding 90 days each. Extension requests must be in writing and Provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 02/13/2007 , your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, d feirdshall, Permit Technician xc: Permit File No. D05 -211 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax. 206 -431 -3665 Z QQ �: W� J U UO CO w =` J � N LL w O L L (0 :D . = W Z H O Z F-' w UJ Do ON D H w �U W �. iii N O Z ILA V ,� x �J�(•. . .. .. , 1 ..ti��3�� o ='�� .. � City o f Tukwila Steven M. Mullet, Mayor r ' Department of Community Development Steve Lancaster, Director �s08 August 25, 2006 Ron Haight Haight Roofing Company, Inc. 4910 15 Av NW Seattle, WA 98107 RE: Request for Extension Development Permit No. D05 -211 700 Andover Pk W Dear Mr. Haight: This letter is in response to your written request for an additional extension to Permit No. D05 -211. The City of Tukwila Building Division will be extending the expiration date of your permit for an additional 180 days (through February 13, 2007). If you should have any questions, please contact our office at (206) 431 -3670. Sincerely Je fer arshall i e hnician File: Permit No. D05 -211 P: Uennifer\Extension LettersTennits\D05 -21 lb Permit Extension.doc Page 1 of 1 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax. 206 - 431 -3665 s August 17, 2006 HAIGHT ROOFING COMPANY, INC. 4910 -15` Ave. NW Seattle, WA 98107 (206) 784 -8414 / Fax (206) 784 -1058 INDUSTRIAL /COMMERCIAL ROOFING, WATERPROOFING & SH EET METAL WORK LIGHTWEIGHT INSULATING CONCRETE ROOF DECKS REROOFING SPECIALISTS City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 Attn: Mr. Bob Benedicto Re: Permit No. D05 -211 700 Andover Park West Tukwila Dear Mr. Benedicto, y RECEIVED AUG 2 12006 COMMUNITY DEVELOPMENT The reroofing work referenced above was suspended due to discovery of substantial problems regarding construction of a secondary roof deck built above the original structural roof deck. This condition was revealed during the initial project inspection and j resulted in the immediate suspension of any further work pending determination of an acceptable solution. At that time the owner couldn't fund the additional work necessary to comply with the changed conditions and the exposed roof decking was sealed using a temporary application of a nailed base sheet with one ply of fiberglass felt set in hot asphalt and surfaced with a glaze coating of hot asphalt. New sheet metal coping has been installed to protect the parapet where the existing coping had been destroyed during removal. To date the owner has paid for labor used to date and materials purchased for the original scope of work. These materials are stored in our warehouse. Unfortunately, the owner had already established their capital improvement budget for this fiscal year and missed the opportunity to accommodate the doubled cost of the changed work for this season. As such we still anticipate completing the work as soon as the owner's funding is re- established. For these reasons we are requesting an extension of the above referenced reroofing permit and anticipate completing the project early next Spring. We appreciate your MEMBERS ROOFINGCONTRACTORS Assoc. OFWA /W ESTERNSTATESRCA/ NRCA/ BIAW/ MASTER BUILDERS Assoc. Washington State Contractors Registration Number HA- 1G- HR- C269QK Z U O (0 cl: . .W = J S2 LL w J U- j. W a Z �. E-- 0 Z ~, � o� o N: o W W : u. 0; w Z U N Z "Since 1919" consideration of this unusual predicament; if you have any questions please feel free to contact me anytime. [Fee _ Members: Roofing Contractors Association, Seattle, Washington / National Roofing Contractors Association Washington State Contractors Registration Number 223- 01- HA- IG- HR- C2690K o : 1908 07 - 03 - 2006 City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director CHUCK MAHLUM 4910 15 AV NW SEATTLE WA 98107 RE: Permit No. D05 -211 700 ANDOVER PK W TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. i i Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. �. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for additional periods not exceeding 90 days each. Extension requests must be in writing and provide satisfactort reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 08/17/2006, your permit will become mull and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, O itfeshall, Permit Technician xc: Permit File No. D05-211 Z Z AW D U UO CO) C3 CO) =: C �. W O' LL Q' N � + (3, W Z �. �- O'. Z F- LU Dp U tn` F- W W Z LL _O. !tl Z U C0 F= _ O F_ Z 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washin;ron 98188 • Phone: 206.431 -3670 • Fax: 200- 431.3665 i 11 A �w , otf Z Departm 1908 January 20, 2006 Chuck Mahlum Haight Roofing Company, Inc. 4910 15 Av NW Seattle, WA 98107 f RE: Request for Extension j Development Permit No. D05 -211 700 Andover Pk W i Dear Mr. Mahlutn: j This letter is in response to your written request for an extension to Permit No. D05 -211. The City of Tukwila Building Division will be extending the expiration date of your permit for an additional 180 . days (through August 17, 2006). d If you should have any questions, please contact our office at (206) 431- 3670... . Sincerely, w 4 �J Jv i arshall Permit Technician f File: Permit No. D05 -211 P:VennifeAlixtension LettecsO05 -211 Permit Extension doc Page 1 of 1 jem City of Tukwila Steven M. Mullet, Mayor ent of Community Development Steve Lancaster, Director - 431 -3670 Fax: 206 -431 -3665 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 HAIGHT ROOFING COMPANY , INC. 4910 -15 Avenue NW Seattle, WA 98107 (206) 784 -8414 / Fax (206) 784 -1058 INDUSTRIAL /COMMERCIAL ROOFING, WATERPROOFING AND SHEET METAL WORK LIGHTWEIGHT INSULATING CONCRETE ROOF DECKS REROOFING SPECIALISTS January 18, 2006 RECEIVED fJAN 19 2006 COMMUNITY DEVELOPMENT Jennifer Marshall City of Tukwila Department of Community Development 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 RE: Permit No. D05 -211 700 Andover Park West, Tukwila Dear Jennifer: Thank -you for the letter dated January 3, 2006 reminding us of the status of the above - mentioned permit. During our pre -roof meeting, it was determined by the City of Tukwila, that it would be necessary to add insulation above the roof deck. Due to the time of year and the material availability, we were unable to start this project before the record rainfall we have been experiencing, began to fall. We respectfully request a one -time extension of 180 days and appreciate your consideration. Sincerely, Haight Roofing Company, Inc. 0 Chuck Mahlum Project Manager MEMBERS ROOFING CONTRACTORS ASSOC. OF WA /WESTERN STATES RCA / NRCA / BIAW / MASTER BUILDERS AS SOC. Washington State Contractors Registration Number HA- 1G- HR- C269QK z Z Z �W �D 0 0 CO) 0: CO) = � iu- .U. ?; � �w _. z� I- 0; D o' 0 cn W Ui Z U= O f.. z "Since 1919" PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D05 -211 DATE: 06 -21 -05 PROJECT NAME: VACANT - ANDOVER PARK WEST SITE ADDRESS: 700 -768 ANDOVER PARK WEST X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after /before permit is issued DEPARTMENTS B i ng Division ® Fire Prevention Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator X_ DETERMINA13ON OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 06 -23 -05 Complete Incomplete ❑ Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS R UTING: Please Route Structural Review Required REVIEWER'S INITIALS: ❑ No further Review Required ❑ DATE: APPROVALS OR CORRECTIONS DUE DATE: - 07-21-05 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: PERMIT COORD COPY Documents/routing slip.doc 2 -28.02 z z �w QQ JU UO Cl) C0 W J � w J L� Cl =w �_ z F.. t= 0 z t-- LU �p O UY off W uj X IL —0 W z U= O z DEPARTMENT OF LABOR AND INDUSTRIES REGISTERED AS PROVIDED BY LAW AS CONST CONT GENERAL `f�'= ..t�_ y��._ �y% pSn •c�r.�yi ; + r •,��.- ,c�s:�..:� ;.�;c �.. .�t:� ^ :., y c! ti�.'^ ' -:�yF •: c-. ;'t�'�. y.i. S -�- •.L "'mss %i;. � .at% T, = �'i.;�r 1�a..- �...f:•"Y!. 1•r, '4• - � � .: C' elr'.yrL:.'F.y -� .�• �.�.:RF- ,G2 #SZ? °- ��: #1i_,.i: � EXP .�+ .,'.- . ,.Y � . _ ; - �� • � DATE'. .'Y1:2_Q • .. .. VE`:'DATE:" 2:. HAIGHT ROOFING COMPANY INC - • .4910 15TH•AVE N.W' SEATTLE WA 98107 F625 -052 -000 (8/97) ,`�,,���. DAR �•,, \ W i ��� � � Y •� Z = UBI. Vo o o =� • TpBER �� //tut ► u Nliii` ,`�,,���. DAR �•,, \ W i ��� � � Y •� Z = UBI. Vo o o =� • TpBER �� //tut ► u Nliii` f File: D05 -0211 35mm Drawing #1 83IN30 li'v'e 83d �� i ► I YIVM(11 :1O A.UO i7.3,A13�3a hlMlllll1 II►►I►�2 ►►1►,�II,I� ► IIIiII li�(� +Illy Iii111117 Illi�ilal I ►Iflllll� 1 91 2 13 14 f lfll I(If i11f IIII IIli�1111 IIIllllll IIITI�iiI�IIII�IIiI II : ,110 ` 111 111 115 � • !N� } � `e �i� 'It.� r J f� (jjj i"'C'+.*�..,,� �� 1 a T i;'" y .. I (` �. a' A� 'dAr yNi t tj.:ti 9W 4oul ���I J�I _�ILI (I,I Ii I��.I_�II`i� I � • I I _ ____._. ________..�_.(__L-1� I I L:LI l l l:laa 1,1:11.1 I ► II _ I I ► I ► I. I � � � (i l_i,l MINKLER BOULEVARD ,L CA ill-Jull l c J Q > O o C > n --� ZZ a 00 � co '� C rn cf),