Loading...
HomeMy WebLinkAboutPermit D05-220 - BENEFICIAL FINANCE - TENANT IMPROVEMENTBENEFICIAL FINANCE DOS -220 •r4 • JU, - 0 0; N W I J � N LL: u. WO} J 'N d • i=- _ Z� Z t- ut La. U 0: :0 H. • O: • Z • W - • - 0E- Z DEVELOPMENT PERMIT Steven M. Mullet, Mayor Steve Lancaster, Director Parcel No.: 0223100080 Permit Number: DOS-220 Address: 415 BAKER BL TUKW Issue Date: 07/25/2005 Suite No: Permit Expires On: 01/21/2006 Tenant: Name: BENEFICIAL FINANCE Address: 415 BAKER BL, SUTIE 104, TUKWILA WA Owner: Name: BAKER SQUARE RETAIL BLDG PT Phone: Address: C/O SOLLY BRUCE DEVELOPMENT, 415 BAKER BLVD STE 200 Contact Person: Name: DOUG POESCHEL Phone: 206 - 276 -3754 Address PO BOX 6315, FEDERAL WAY WA Contractor: Name: RIVER CITY CONSTRUCTION INC Phone: 253- 939 -4545 Address: PO BOX 6315, FEDERAL WAY, WA Contractor License No: RIVERCC1170B Expiration Date: 06 /06/2007 DESCRIPTION OF WORK: TENANT IMPROVMENT - SPACE EXPANSION, REMOVE AND ADD NEW WALLS. Value of Construction: $54,000.00 Fees Collected: $1,378.46 Type of Fire Protection: SPRINKLERS International Building Code Edition: 2003 Type of Construction: VB Occupancy per IBC: 0008 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Flood Control Zone: N Hauling: N Land Altering: N Landscape Irrigation: N Moving Oversize Load: N Sanitary Side Sewer: N Sewer Main Extension: N Storm Drainage: N Street Use: N Water Main Extension: N Water Meter: N Number: 0 Start Time: Volumes: Cut 0 c.y. Start Time: f Size (Inches): 0 End Time: Fill 0 c.y. End Time: Private: Public: Profit: N Non - Profit: N Private: Public: doc. IBC - Permit 005 -220 Printed: 07 -25 -2005 City a. lTukwila Department of Commutdty Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: cOukwila.wa.us Z W: D UO Cl) o . LU J CO) LL w O U _ U) c i d. �w Z �. z O UJ � o O CO w F U` U. O Z U H- 0 : Z I �J�� "kgiP N 2 .r iso8 y City o : Tukwila Steven M. Mullet, Mayor Departnietit of Community Development Steve Lancaster Director 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: cOukwila.wa.us Permit Number D05 -220 Issue Date: 07/25/2005 Permit Expires On: 01/21/2006 Permit Center Authorized Signature: Date: 7/S � I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The ng�of this permit does not 1 esume to give authority to violate or cancel the provisions of any other state or local laws regu sting construction or the performance of wor I am uthorized to sign and obtain this development permit. Signature: d Date: 1' Print Name: E 1 This permit shall become null void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IBC- Permit D05 -220 Printed: 07 -25 -2005 1 Z Z '. W 2 Q � ... J V U0 , co o. w= J H CO u,,. W 0; LL Q S2 d' H= Z z0 W LLJ � o U 0 - off w L 0 iu Z U N H X O Z City of Tukwila Department of Community Development 16300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 PERMIT CONDITIONS Parcel No.: 0223100080 Permit Number: DOS-220 Address: 415 BAKER BL TUKW Status: ISSUED Suite No: Applied Date: 06/28/2005 Tenant: BENEFICIAL FINANCE Issue Date: 07/25/2005 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design requirements of ASCE 7. 6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. 7: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 8: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Department of Public Health - Seattle and King County (206/296- 4932). 10: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department of Labor and Industries (206/248- 6630). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: ** *FIRE DEPARTMENT CONDMONS * ** 13: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 14: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) doc: Conditions D05 -220 Printed: 07 -25 -2005 i r.. ^'r,} , fr.'o n {.wtt.,..t�i .v �r+y;• d4. ,. �.. ��.•a�Y+..s; `•('" a"•.. c• ; _. 1.. ,1. . L:, u 4.,,.:1, _ /,.:.' ,;:' �k?- vsH":.<: i3'` �: r° , :- , a'Trri'r;vie4�vi'tivjui,� ; � : +:c?. ti':t: #?<ildr, t� +ef• . wt7 .M 3'hytl + ki.:� %iiq w. ,J. :i�.cE �..tx -'�:i t� z �z '~ w �0 UO No Cl) Nw W 0 U. = C1 �w Z H 1--0 Z W w U� O N � 1— wW U_ w Z U= O Z ti City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 15: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or Q brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation _ instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so W that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross 2 weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the o floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 U o Cl) inches (102 mm). (IFC 906.7 and IFC 906.9) w = 16: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot CO u_ be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) g 0 17: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available a for use. These locations shall be along normal paths of travel, unless the fire code official determines that the to d hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) w Z 18: ** *MEANS OF EGRESS * ** - IFC Chapter 10 F .. p 19: No point in a building may exceed the maximum exit access travel distance listed in Chapter 10, section 1015, Table Z�_ w w 1015.1 of the International Fire Code and International Building Code. v o -- 20: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. O 0 H (IFC 1008.1.8.3 subsection 2.2) H v 21: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle � O Z iw is engaged from inside the tenant space. (IFC Chapter 10) co 22: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) z ~ 23: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 24: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 25: Means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. The means of egress illumination level shall not be less than 1 foot - candle (11 lux) at the floor level. The power supply for the means of egress illumination shall normally be provided by the premise's electrical supply. In event of a power failure an emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 26: ** *FIRE ALARM SYSTEMS * ** - City Ordinance #1900 - NFPA 72 27: Maintain automatic fire detector coverage per N.F.P.A. 72. Addition/ relocation of walls, closets or partitions may require relocating and /or adding automatic fire detectors. 28: Maintain fire alarm system audible /visual notification. Addition /relocation of walls or partitions may require relocation and /or addition of audible /visual notification devices. (City Ordinance #2051) doc: Conditions D05 -220 nted: 07 -25 -2005 J... r: ..a a,.,� is �.�r...Ze".!.`,t ::i 4..: ir�'un;��'K,t::3i. v..t rrl s�l'x� "•� ,• �F ..:ii �X �� , t 7.oi . ' 2iSknnYri w :.:i',' :�4n� .0 r� :.'s � .: i.: H: v,: n::. wir. o- ..4,::s. +.acs,�t.L.:u.:.;.'µ -.Lx.rt•' City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 29: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 30: Call the Tukwila Fire Department at 206/575 -4407 for approval of any system shut down. Have job site address, name and 3 the Tukwila Fire Department Job Number available to confirm shut down approval. (City Ordinance #2051) ! 31: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 32: ** *BUILDING CONSTRUCTION * ** - IFC - IBC i 33: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 34: Accumulation of combustible waste material is prohibited during the demolition phase of this project. Remove and properly dispose of all waste material prior to the close of the working day and as often throughout the day as needed. 35: These plans were reviewed by Inspector 510. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. * *continued on next page ** z Z W W U O' U) 0 J � L W 2� LLa CC%: =w z F- ZO w w U 0' ' O S off 2V H� O' U — . p _ O ~' Z ! doc: Conditions D05 -220 Printed: 07 -25 -2005 r Cit y of Tukwila 1908 Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 (206) 431 -3670 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating - construction or the performance of work. Signature . .-- fir~ ,�i 6 Date Print Name: doe: Conditions D05 -220 Printed: 07 -25 -2005 (W o"3 - *IL A, w CITY OF T UKWI LAS � Community Developmebt department Public Works Department Permit Center 1908 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 i Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SIMEOCATION King Co Assessor's Tax No.: eo?, Site Address: V 'J a k w l tJ Suite Number: Floor Tenant Name: CJ ` t�Qw New Tenant: ❑ .. Yes 2'.No Property Owners Name: 4 r- tA d C Mailing Address: �Q City State Zip .`CONTACTPERSON . Name: (I Day Tel phone: S Mailing Address: < � E -Mail Address: �03,2 S [' lL e f T� 1.M( CtA Ste of Fax Number: a 3 9 3 9 — 4 /3 �f GENERAL CONTRACTOR INFORMATION - (Mechanical Contractor information on back page) Company Name: Mailing Address: City / State Zip / Contact Person: P 6 Day Telephone: C.CJ (O E -Mail Address: V. Fax Number: -� -7 Contractor Registration Number: Expiration Date: f� — 7 * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** :ARCHITECT OF RECORD. - All plans must be wet stamped by Architect of Record Company Name: OW��D Mailing Address: ✓` --� city state Z � � u Contact Perso Day Telephone: I 7 —, Q E -Mail Address: Fax Number: 6 �� ENGINEER OF RECORD All plans must be wet stamped by Engineer of Record Company Name: Mailing Address City State Zip i Contact Person: Day Telephone: E -Mail Address: Fax Number: gAkpc mhs pluslicc changesXpemit application (7 -2004) Revised: 6.8.05 Page t bh Z W UO N CO W J = F— CO W WO 2 QQ tL CO) = �W Z �O Z �_ WW U� ON OH W H 160 .Z W U= 0 �.. Z BVILDING PERMIT, INFORNYAfION' 206- 431 -3670 :........ Valuation of Project (contractor's bid price): $ lb 7 . U l�J ,�� Existing Building Valuation: $ Scope of Work (please provide detailed info ation): CA 'i 1 I Will there be new rack storage? ❑ 2 ,/ ..Yes •• No If "yes ", see Handout No. for requirements. Provide All Building Areas in Square Footage. Below PLANNING DIVISION: Single- family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ ....Yes ❑ ..No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑.. Sprinklers Automatic Fire Alarm []..None ❑ . Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ ..Yes 2r If ' yes ", attach list of materials and storage locations on a separate 8 -112 x II paper indicating quantities and Material Safety Data Sheets, q:Vpermits plus \ice changes%permit application (7.2004) Revised 6•8-05 Page 2 bh �t ZZ — Z �W Q � Q � JU 0 (I)0 CO) 11i J � U. WO J W Q. = FW Z H Z� �5 U O CO) 0 H- W ~ H L O. LLI Z CO) P H: O Z Existing Interior . Remodel Addition to Existing Structure New Type of 'Construction . per IBC Type of Occupancy per IBC I" Floor gig 2 ". Floor r P Floor Floors thru Basement . Accessory Structure* :. Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single- family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ ....Yes ❑ ..No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑.. Sprinklers Automatic Fire Alarm []..None ❑ . Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ ..Yes 2r If ' yes ", attach list of materials and storage locations on a separate 8 -112 x II paper indicating quantities and Material Safety Data Sheets, q:Vpermits plus \ice changes%permit application (7.2004) Revised 6•8-05 Page 2 bh �t ZZ — Z �W Q � Q � JU 0 (I)0 CO) 11i J � U. WO J W Q. = FW Z H Z� �5 U O CO) 0 H- W ~ H L O. LLI Z CO) P H: O Z MECHANICAL PERMIT INFL..MATION - 206- 431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance" Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): f i Use: Residential: New .... ❑ Replacement..... ❑ Commercial: New .... ❑ Replacement..... ❑ i i Fuel Type Electric ..... ❑ Gas .... ❑ Other: Indicate type of mechanical work being installed and the quantity below: Unit T e: Qty Unit Type: Qty Unit Type: Qty Boiler/Compressor: Q Furnace <100K BTU Air Handling Unit >10,000 Fire Damper 0 -3 HP/ 100,000 BTU CFM Furnace>100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected Thermostat 15 -30 HP /1,000,000 BTU to Single Duct Suspended/Wall /Floor Ventilation System Wood /Gas Stove 30 -50 HP /1,750,000 BTU Mounted Heater Appliance Vent Hood and Duct Water Heater 50+ HP /1,750,000 BTU Repair or Addition to Incinerator - Domestic Emergency Heat/Refrig/Cooling Generator System Air Handling Unit Incinerator — Comm/Ind Other Mechanical <10,000 CFM Equipment PERMIT APPLICATION` NOTES - Applicable.to ` 11,permits in this.application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Bui ding Code (current edition). . I HE BY CERTIFY THAT I HAVE READ AND EXAMINED THIS IPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY 13F PERJURY BY THE LAWS - QF THE STATE OF W AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUIL ING O ER OR Signatu Lr Print Name: Mailing Address: Day City ,Date: 7 V ^3 /, State Zip Date Application Accepted: Date Application Expires: Staff l d 'als: �- q:\\purnits plus\ice changes \permit application (7.2004) Revised: 6.8 -05 bh Page 4 Z }�- Z �W W Q2 JU u to 0 CO LLJ J � to LL WO 9 J LL Q C = �W Z H H O Z LU �5 U� O� 0 1— W 3: L ) —0 .• Z W F _ O Z I f Tukwila face Y l j 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 RECEIPT Parcel No.: 0223100080 Permit Number: Address: 415 BAKER BL TUKW Status: Suite No: Applied Date: Applicant: BENEFICIAL FINANCE Issue Date: DOS -220 APPROVED 06/28/2005 i : E Receipt No.: R05 -01084 Payment Amount: r Initials: BLH Payment Date: User ID: ADMIN Balance: 4 Payee: RIVER CITY CONSTRUCTION I i. TRANSACTION LIST: i . Type Ifethod Description Amount t--- - - - - -- -- - - - - -- --------------------- - - - - -- ------ - - - - -- j Payment Check 16514 837.20 I I ACCOUNT ITEM LIST: .Description Account Code Current Pmts BUILDING - NONRES 000/322.100 832.70 1. STATE BUILDING SURCHARGE 000/386.904 4.50 I i Total: 837.20 837.20 07/25/2005 09:01 AM $0.00 doc: Receipt Printed: 07 -25 -2005 City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 i (206) 431-3670 RECEIPT Parcel No.: 0223100080 Permit Number: D05-220 Address: 415 BAKER SL TUKW Status: PENDING Suite No: Applied Date: 06/28/2005 Applicant: BENEFICIAL Issue Date: Receipt No.: R05-00934 Payment Amount: 541.26 Initials: BLH Payment Date: 06/28/2005 10:42 AM User ID: ADMIN Balance: $837.20 Payee: RIVER CITY CONSTRUCTION INC TRANSACTION LIST: Type Method Description Amount ---------- -------- --------------------------- ------------ Payment Check 1695 541.26 .z Z' QQ JU .0 0: U) LU wx� -j F- 0 U-' ' a w U- U) CY LU P 0 z ~- I . O to LLJ LLJ F- LL ... Z LU �0 F-� z ;.r"'35 X76; --'�7 i ii 'T1')Tt!L VA, I doe: Receipt Printed: 06-28-2005 t i INSPECTION RECORD Retain a copy with permit INSPECTION NO. PE MIT NO f CITY OF TUKWILA BUILDING DIVISION "' ► 6300 S,outhcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project r Type of Inspectio Addr s. 1 Date Called: Special instructions: Date Wanted: r U��.m. Requester: Phone No: .r �3/-7 u u paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspectio Receipt No.: Date: f Y f Z Z Q� W W �• JU 00' CO) =. H W O. -j LL Q N d ~W Z . H O W LL1, :O co C) t•- W W, IL H U U I-- L ' r . INSPECTION RECORD Retain a copy with permi *(2 61431.3 ' INSPECTION NO. CITY OF TUKWILA BUILDING DIVISIO Southcenter Blvd., #100, Tukwila, WA 98188 70 G M Approved per applicable codes. Corrections required prior to approval. fkQ ject: Type of In pection: d ress: � � . � Date Call d: a a Spe ial Instructions: Date Wanted: M. 3 p.m. o �� Requester: P ^ z �_— Z Q �W W� UO W =' Co U W O �5 U. �. =a �.. W �O .z H U� .O N. WW U- O .z W v =: z { INSPECTION RECORD r Retain a copy with permit ��- INSPECTION NO. PER CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 ( 0 431 -3670 Proj ct: Type of In ection: A ess: Datd Called: J Special Instructions: Date Want d: Iti Requester: Phon o� .mss- ao proved per applicable codes. Corrections required prior to approval. 9 BENTS: I / Inspector: v Date: - $58. REINSPECTION EE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcen er Blvd., Suite 100. Call to sechedule reinspection. Receipt No.: Date: Z Z'. �}" W _3 UO W LLI �L WO Ei U. U = CJ �W F- O W H, W U O TO oF- W w F- C.) � 0 tll Z, CO) O Z City of Tukwila Fire Department TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Permit No. I j r Project Name j . Address /a Inc ke 1 Suite # /o Y 1� Retain current inspection schedule Needs shift inspection Approved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: Occupancy Type: FPO `/ - - Authorized Signature Date Final Approval Frm Rev. 5/2/03 T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206 -575 -4404 • Far: 206 -575 -4439 . z . � mo w: u�l � UO CO) J H D U_ W LL a . N � = �o zF U N =U LL ~O' w z U CO) O ~ _ Z.. 2003 Washington State Nonresidential Energy Code Compliance Form Project Info Project Address BENEFICIAL FINANCE Date 6/22/2005 415 BAKER BLVD., SUITE 104 For Building Department Use RECEIVED CITY OF: TUKWILA► ,• 1:; e'. " J PERMIT CENTER TUKWILA, WASHINGTON 98188 Applicant Name: Applicant Address: IN Applicant Phone: Project Description 13 New Building Addition ® Attera ion Mans Included Refe WSEC Section 1513 for controls and commissioning requirements. Compliance Option C Prescriptive Lighting Power Allowance Q Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box) Q No changes are being made to the lighting Q Less than 60% of the fixtures are new, and installed lighting wattage is not being increased Maximum Allowed Lighting Wattage (Interior) Location (floor /room no.) Occupancy Description Allowed Watts per fe " Area in ft' Allowed x Area WHOLE BLDG. RETAIL BANKING 1.5( 1769. 2653. 103,104,108 2 X 4' PRISMATIC TROFFER, (3) F32T8,BLECT BALLAST 5 93. ( 837. Open Parking 0.2 W /f? From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Wa 2653 . Noies: { 1. Use manufacturer's listed maximum input wattage. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used 2. Include exit lights unless less than 5 watts per fixture. t Proposed Lighting Wattage ( Interi Ist all fixtures For exempt lighting, not exception and leave Watts/Fixture blank. Location (fioodmom no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed 101,102,105,106 2' X 4' PRISMATIC TROFFER, (4) F32T8,ELBCT BALLAST 1 114. 17 10. 103,104,108 2 X 4' PRISMATIC TROFFER, (3) F32T8,BLECT BALLAST 5 93. ( 837. Open Parking 0.2 W /f? Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watt 5 2547. Maximum Allowed Lighting Wattage4ExteriUr) I i i� Location REVIEW-_L CODE 'QMp IANCE ° Description Allowed Watts per fe or per If Area in t f (or If for perimeter ) Allowed Watts x fl? (or x If) Covered Parking (standard paint) 1'- f"N" V^ ` 0.2 WHIF Covered Parking (reflective paint) J U L r7 Z�Q U +� 0.3 W /f? Open Parking 0.2 W /f? Outdoor Areas _ - 0.2 W /ft Bldg. (by facade) / (1� -} ! �l/lll % 0.25 W/ft Bldg. (by Perim) , :� }�..: E i`'?t.,� i V L: t . ;t'i, '. 7.5 Wif Note: for building exterior, choose either the area or the perimeter method, but not both) Total Allowed Watt vse "119F 115teu inaximurn input wattage. rur nxwies wnn naru - wueu uanasw unry, i Proposed Lighting Wattage (Exterior) default table in the NREC Technical Reference Manual may also be used. Location Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Total Proposed Watts may not exceed Total Allowed Watts for Exterior Total Proposed Watt Z Z �w QQ JU U0 CO W = t— U) LL w Q to I. W Z H O Z w U� . N. � f^ WW H U. .. Z W CO) O Z A, 2003 Washin State Nonresidential Energy Code Compliance Form 2003 Washington Slate Nonresidential Energy Code Compliance Forms Revised July 2004 Prescriptive Spaces I Occupancy: 0 Warehouses, storage areas or aircraft storage hangers iD Other Qualification Checklist Note: If occupancy type is "Other" and fixture answer is checked, the number of fixtures in the space is not limited by Code. Clearly Indicate these spaces on plans. If not qualified, do LPA Calculations. Lighting Fixtures: 0 Check here if at least 95% of fixtures in the space meet all four criteria: 1. Fixtures are fluorescent, non - lensed, with only one or two lamps, and 2. Lamps are T -1, T -2, T -4, T -5, T -6, T -8 3. Lamps are 5 -50 Watts, and 4. Ballasts are electronic ballasts 5. Exit lights < 5 watts /fixture 6. Screw -in compact fluorescent fixtures do not q ualify TABLE 15 -1 Unit Lighting Power Allowa (LPA) Use LPAz (W /sf) Use LPA (Ulf /sf) Painting, welding, carpentry, machine shops 2.3 Police and fire stations" 1.5 Barber shops, beauty shops 2.0 Atria atriums 1.0 Hotel ban uet/conference/exhibition hall ' 2.0 Assembly spaces auditoriums, gymnasia heaters 1.0 Laboratories 2.0 Group R -1 common areas 1.0 Aircraft repair hangars Cafeterias fast food establishments 1.5 1.5 Process plants Restaurants/bars 1.0 1.0 Factories workshops, handlin areas 1.5 Locker and/or shower facilities 0.8 Gas stations, auto repair shops 1.5 Warehouses ", storage areas 0.5 Institutions 1.5 Aircraft storage hangars 0.4 Libraries Nursing homes and hotel/motel guest rooms 1.5 1.5 Retail retail banking Parking garages 1.5 See Section 1532 Wholesale stores (pallet rack shelvin 1.5 Mall concourses 1.4 Plans Submitted for Common Areas Ont Schools buildings (Group E occupancy only), school classrooms day care centers 1.35 Main floor building lobbies' (except mall concourses 1.2 Laundries 1.3 Common areas, corridors, toilet facilities and washrooms elevator lobbies 0.8 Office buildings, office /administrative areas in facilities of other use types (including but not limited to schools" hospitals, institutions, museums, banks, churches 1.2 Footnotes for Table 15 -1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The wafts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) Includes pump area under canopy. 7) In cases in which a fighting plan is submitted for only a portion of a floor, a Unit Lighting Power Allowance of 1.35 may be used for usable office floor area and 0.80 watts per square foot shall be used for the common areas, which may include elevator space, lobby area and rest rooms. Common areas, as herein defined do not include mall concourses. 8) For the fire engine room, the Unit Lighting Power Allowance is 1.0 watts per square foot. 9) For indoor sport tournament courts With adjacent spectator seating, the Unit Lighting Power Allowance for the court area is 2.6 watts per square foot. 10) Display Window illumination installed Within 2 feet of the window, lighting for free - standing display where the lighting moves With the display, and building showcase illumination where the lighting is enclosed Within the showcase are exempt. An additional 1.5 We of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted With tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. Z �Z W QQ� 0 N o CO W W = H CO LL W O LL Q to Z d �W Z =. F- I- O Z i- W U� O N ID � WW � U' U_ 0 . L1J Z. to H F=- O Z t .L 2003 Washin ton State N Li ghting Pe rmit 2003 Washington Slate Nonresidential Energy Code Compliance Fortes Code Compliance Form Project Address BENEFICIAL FINANCE Date 6/22/2005 The following information is necessary to check a lighting permit application for compliance with the lighting requirements in the 1994 Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component Information Require Locatio on Plan Building Department Note, LIGHTING CONTROLS (Section 1513) yes 1513.1 Local control /access Schedule with type, indicate locations E -2 yes 1513.2 Area controls Maximum limit per switch E -2 yes 1513.3 Daylight zone control Schedule with type and features, indicate locations yes vertical glazing Indicate vertical glazing on plans E -2 r.. overhead glazing Indicate overhead glazing on plans r • a • 1513.4 Display /exhib /special Indicate separate controls 1513.5 Exterior shut -off Schedule with type and features, indicate location r • a • (a) timer w /backup Indicate location r • a • (b) photocell. Indicate location 1513.6 Inter. auto shut -off Indicate location r • a. 1513.6.1 (a) occup. sensors Schedule with type and locations r.. a. 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans 4 1513.7 Commissioning Indicate requirements for lighting controls commissioning E -2 yes Lighting Sum. Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture ALSO SEE E -2 r.. a. Elec motor efficiency MECH -MOT or Equipment Schedule with hp, rpm, efficiency If "no" is circled for any question, provide explanation: Z i= Z �W QQ � JO UO Nc U) UJI J= fH IL W O. UQ N d = W H Z 1_ O Z H W Lu U O CO. � F- WW H �O .. Z W U CO O Z i 1908 July 13, 2005 ;y City of Tukwila Steven M. Mullet, Mayor •'� Department of Community Development Steve Lancaster, Director Doug Poeschel PO Box 6315 Federal Way, WA 98063 RE: CORRECTION LETTER #1 Development Permit Application Number D05 -220 Beneficial Finance – 415 Baker BI Dear Mr. Poeschel: This letter is to inform you of corrections that must be addressed before your development permit(s) can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time, the Planning, Public Works and Fire Departments have no comments. i Building Department: Ken Nelsen, at (206) 431 -3677, if you have questions regarding the ( attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) complete sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. j In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accented through i the mail or by a messenger service. If you have any questions, please contact me at (206) 433 -7165. Si cerely, i Brenda Holt Permit Coordinator i encl xc: File No. D05 -220 i 4 PAplanning %rendAD05 -220 — correction Itr N l.doc bh 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax. 206 - 431 -3665 i Z Z Ui 3 0 0 CO) =. t` N U. w 0 U— = CY E.. w Z� F- o. LU5 � o W w : U LL ~O ui Z U= O ~. Z... Building Division Review Memo Date: July 11, 2005 Project Name: Beneficial Finance, permit application Application #: D05 -220 Plan Review: Ken Nelsen, Senior Plans Examiner An initial Building Division plan review has been conducted on the subject permit application. Only one item of concern has been noted at this time. Please address the following comment with revised plans and/or other applicable documentation. 1. The new location for the rear egress door #106, will swing into the existing hallway and may project more then allowed by IBC Section 1008.1.2. Revise the direction of the door swing in toward the space, or relocate the door to a location that would not require it to project in to the hallway's clear width and accessible maneuvering space per IBC Chapter 11. No further comments at this time. Z Z' LU JU UO U U. wi J f' U- 0 J. a_ Q co d' =w. i-- _ z� Z W 2 5. U ;O w w` H U i6 �. ..Z U N' O � . Z ,- 1 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D05 -220 DATE: 7 -13 -05 PR03ECT NAME BENEFICIAL FINANCE SITE ADDRESS 415 BAKER BL Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 1 Revision # After Permit Issued DEPARTMENTS: -oS Buijing Di iv sion Fire Prevention ❑ Planning Division ❑ j e Public Works ❑ Structural ❑ Permit Coordinator . DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 7 - 14-05 Complete d Incomplete ❑ Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TOES /THURS R UTING: Please Route Structural Review Required REVIEWER'S INITIALS: ❑ No further Review Required ❑ DATE: APPROVALS OR CORRECTIONS Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routlng slip.doc 2 -28.02 DUE DATE: 5-11 -05 Not Approved (attach comments) ❑ z . �z }' w o aa C 2 WU 00 ND C0 W J S2 LL w U- Q � i .-w z Z0 LLJ W U o O (1) OH w w LL Z' UN F O ~' z PLAN R SLIP ACTIVITY NUMBER D05 -220 DATE: 6 -28 -05 PROJECT NAME BENEFICIAL FINANCE SITE ADDRESS 415 BAKER BL, SUITE 104 X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: � S: t / � 4w(, N o-3o 9 Buildin Division Fire Prevention P Pan ni Division Publi Works Z Structural ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 6 Complete d Incomplete ❑ Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TOES /THURS RO TING: Please Route Structural Review Required REVIEWER'S INITIALS: ❑ No further Review Required ❑ DATE: APPROVALS OR CORRECTIONS Approved ❑ Approved with Conditions ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg N, Fire ❑ Ping ❑ PW ❑ Staff Initials: DUE DATE: 7-28 Not Approved (attach comments) E� z Z w u� D . �U UO (/) W = F— N LL w 9a �d =w z �. �o w ~ w U CO C3 I-- w ti 0 ..z w U= O~ z City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us `'` ` REVISION SUBMITTAL : x Revision: submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 7____r = /3 .— � Plan Check/Permit Number: Response to Incomplete Letter # 0 to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name:_ Project Address: Contact Person: Summary of Revision: e �f -.� Sheet Number(s): "Cloud" or highlight all areai of revision including date of revision Received at the City of Tukwila Permit Center by: 1 E 6 4 AL RECEIVED Entered in Permits Plus on CITY OF TUKWILA app ications orms- applications on line evision submittal J U L Created: 8 -13 -2004 Revised: PERMIT CENTER z Z �W JU UO 0 W= H C0 LL w O. �Q T d 3: Z F-. Z0 W5 U� co 0 1— w I-- P', LL .. z w CO) O z Look Up a Contractor, Electrician or Plumber License Detail Washington State Department of Labor and Industries General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. License Information License RIVERCCI170B Licensee Name RIVER CITY CONSTRUCTION INC Licensee Type CONSTRUCTION CONTRACTOR UBI 601139256 Ind. Ins. Account Id Business Type CORPORATION Address 1 PO BOX 6315 Address 2 Cancel City FEDERAL WAY County KING State WA Zip 98063 Phone 2539394545 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 9/2/1989 Expiration Date 6/6/2007 Suspend Date Separation Date Parent Company Until Previous License RIVERCC210134 Next License Associated License Business Owner Information Name Role Effective Date Expiration Date DOWN, ROBERT H 01/01/1980 DOWN, DIANNE L 01/01/1980 Company Bond Information Bond Bond Company Account Effective Expiration Cancel Impaired Bond Received Bond Name Number Date Date Date Date Amount Date TRAVELERS CAS & Until #4 SURETY CO 206853225 09/02/2001 Cancelled $12,000.00 08/10/2001 Page 1 of 3 Z W JU U O CO t] J y H NLL WO J U. Q. N d = W Z �. Z O. W 5. U � O N � F- WW H� �O. . Z . W O Z https:H fortress. wa. gov /lni/bbip /printer.aspx ?License= RIVERCCl 170B 07/25/2005 `'I SIPARATE PEttMI'� WA%m FOR: PhxnNnQ d/ Gas Plp'nj Cry Of TL BUIWI G DIVISION ( ADAMS AUUHGROYY 1(206) 431-3670 A RCHOVECUUREP.C. 0 CODES I550 N NORUHWESU I BErL`AEF0C9AL FONANCE 45 BAKER BLVD, SUffE �04 Do TUKWgLA 000 , WAO 9M [�IIImti� \III[] \A pwna N&ITMs liplo phn iewkw apprmW is subW to errors and orrti skm 4PV4 of cm to cdon dow wilts does not ate ft of any Or *A 1-T KIIIIII a approvW Reid Copy mnd ft ay of Nklk AmAVAmILa:LE AIm IZI I LI (I 111) CEOUNG PLAN a" LEGEND AImI3. FUU'm%NOYUnME/ FONOSH ufl-ILAN SCHEDULES & DEUABLS LOCATION INFORMATION � � � SITE PLAN SME U"Y E P3iVd'0NA Ck 9'ru*769 (tvqY9) 397==3004 p'Afl 397 iAx HFC PROPERTY ENT 1 mm No ch meges : be mob to tM occF I e' vic 7! : At ha t prior a'pprOvAd Of c .�:E`.vi� Bid Q�1/�510rl. -.::.is �Ari! {} r rt • o p '�n ar ± r-E y w..u� fJ�/ to al pl- S. i C .•. ..~ �5. G ROSS S.F.09 - ----------------------- 1.800 ST. .CKo"CUPANU LOAD; MtEA-- 1.8W SLF- • • L OAD lepMsm EGRES& • 1 Nm EXff 1 • t ARCHITECT CODE REVIEW t0 `' Ssy► . o i� : 60Cft T. a diL, :. •Vl ` it • � - i t E tiar ow e s e = _ G ROSS S.F.09 - ----------------------- 1.800 ST. .CKo"CUPANU LOAD; MtEA-- 1.8W SLF- • • L OAD lepMsm EGRES& • 1 Nm EXff 1 • t ARCHITECT CODE REVIEW DOMENSdON PLAN SCHED n DETAOLS E ELE-C UROCAL PLAN PANEL I LEGENDS n ELEVAUBONS 140 Iff \ , •�\ I� T�5•?20 DRAWING INDEX ♦ SIM ho W� C3 0 Z Q w Z w CO Q i —iQ 11MLw W Y — Zm w�� �0 V� " �O Q W 46 a � 0. �to� Q �- =40 40 Z -um U. Lu 3 o 0 CL Z .O a V ZWN rL _aeo ' V4 o tbd� FMI 7 I�i�IS��II ca . d C d m H W W Z W O U Revisiar s 0 O O O D 0 = ♦R f0 V w wMEX - E - 4 SIM :ar. • .r- �►. is s V;i» - 0" w -'Vo NMIM 3w maw WR ar"G *c SgkxT%pn out OP411111110'* Or! AS NOTM IMPOLE ift 05�2208 Smm% cs.mi 4 3 i •Vl ` I� i DOMENSdON PLAN SCHED n DETAOLS E ELE-C UROCAL PLAN PANEL I LEGENDS n ELEVAUBONS 140 Iff \ , •�\ I� T�5•?20 DRAWING INDEX ♦ SIM ho W� C3 0 Z Q w Z w CO Q i —iQ 11MLw W Y — Zm w�� �0 V� " �O Q W 46 a � 0. �to� Q �- =40 40 Z -um U. Lu 3 o 0 CL Z .O a V ZWN rL _aeo ' V4 o tbd� FMI 7 I�i�IS��II ca . d C d m H W W Z W O U Revisiar s 0 O O O D 0 = ♦R f0 V w wMEX - E - 4 SIM :ar. • .r- �►. is s V;i» - 0" w -'Vo NMIM 3w maw WR ar"G *c SgkxT%pn out OP411111110'* Or! AS NOTM IMPOLE ift 05�2208 Smm% cs.mi 4 3 i Djq� 1 N 88'25'27' W 252.66 LEGAL DESCRIPTION BAKER BLVD i Goolowilm F 354.10 NORTH LINE TRACT 8 173.3'4' 10' UTILITIES EASEMENT PER PLAT E p = 89 I R = 50.00' L = 78.11' ------- ------------------------------------------------------ I ` I I ` I NORTHWEST CORNER TRACT 8 ��J �`< • t ' `� E E r I RANDOM SPACED � ET _ -w -- PARKING BUMPER r - - BLOCKS -L I _ y _ 60' GUIDING SETBACK UNE PER PLAT SCALE 1' = 20' 0 20 40 sow n: `• �._S• = �;.- S 1 � L ��^^' - � = - re jLwr Truck RENTON TU-K ILA • F ' .. M me_ 1 a � I � ' ��.4� F `•� 1 �• � � • � : ....tee_ _ -� - _ r sr VICINITY MAP I h��� I � a I 1 ! 1 I I __!•_.__ I o I HANOI -CAP v � %a H e 1 RAMP 11 .01 I ---- ____ -- 1.0 I I I I I 1 I I I I - "•; • • • • ,i •: CONC. WALK _ , ,-- • 1 ', •,' •.• _ ,,• , ., . ..., 71.51 -_ • CON C. i = I ' • �, i I I (.' SLAG •'.,• m I I • GATE I _ -- 45.00 1 HANa -CAP EXISTING BUILDING 4.19 RAMP • E XISTIN G G GARAGE �= -- -- -- 2 - STORY BRICK : • 0 I ° 1 - STORY BRICK ` :I .: I N •: 2- sTOR`r OVERHANG 45.03 4.19 co wM W-- - --- -_ to I I ° OR M •• I I co GAS METERS (2) 71.48 . • I - -- E1.FCTRIC EASEMENT T L : AF 8807111069 j 1 I I I 1 � SOUTH LINE TRA 6 � s � f r IIIIIIIIIIIIIIIIIIII NORTH LINE TRACT 9 + .- C _ 1 I I 1 ! ! 1 1 1 1 I I 1 1 I r r r r I I SLAB ! �•- •..- -•" � 1 1 1 I I 1 ! I 1 1 r l I 1 I • I N 88'25 W 224.93' 0 CHA,N LINK FENCE (TYP) LEGEND .0 Fo M CASE IMM G 51 OR#1 CATCH SAM FEE wfiwj T WA7ER IEIM ELEOTRlC vm&T ) CT mmww 'm Er IRSER ON COWo. PAD 4 co no. REV I S I OHS CE I aT i ow m U c.i 0 U to ❑S SURVEYOR'S CER11FICAlION L GORDON T. PA71MAN1. HII�REBY CER1F7 10 1FE OF FORE5IERS SEATTLE MORTGAGE Ca1PAllY NO 7RANSr1ME30CA TITLE INSURANCE CQWAN1f THAT 1HS WP IS A 7RIJE 1110 ACT REP�lITAl10N OF A SlJR11Elr MADE BY 1E OR UNDER MY OIIiEC'T RESMISINUTY. 7a THE BEST OF MY 9140KED6E AND BELIEF, ALL DiQ190NS AND LOG11106 Sfi0M1 HEREON ARE llllE AND CORRECT /ICOQIDN6 70 FIELD IS MADE SEPT. 219 1991 AT 7FE REQUEST OF 9aLY DEY. CO. 4 24 - 9 -'s1 •l 1 6RD01 T. PA7FYAM1. P.L..S, 1801e p,AW R OJI sy IoInTE . - PATHMANN SURVEYING v ; LAS SUWU SPECIALIST - - - -~ w u%w l m a.Ex SOILY DEVO CO.. INC. RMACT ROYAL VAJLFF SIZE AS -BUILT OYim or GT'p ORTE 911-27-S r A mD 63.06 C7EOIED Ir GTP 9GLE (. = x . 9EEF ( OF r t E I s i t i i Kol THAT PORTION OF TRACTS 8 AND 9 OF ANDOVER PARK NO. 2. AS PER PLAT RECORDED IN VOLUME 71 OF PLATS, PAGES 88 AND 69, RECORDS OF KONG COUNTY, DESCRIBED AS FOLLOWS: BEGINNING AT THE I NORTHWEST CORNER OF SAID TRACT 8; THENCE SOUTH 88 25 EAST ALONG THE NORTH LINE OF SAID TRACT 8, A DISTANCE OF 354.10 FEET TO THE TRUE POINT OF BEGINNING; THENCE SOUTH 01 3 WEST A DISTANCE OF 235.00 FEET; THENCE SOUTH 88 25 27" EAST A DISTANCE OF 224.93 TO THE EAST UNE OF SAID TRACT 9; THENCE NORTH 01 05'06" EAST ALONG SAID EAST UNE A DISTANCE OF 185.43 FEET; THENCE ALONG A CURVE TO THE LEFT HAVING A RADIUS OF 50.00 FEET AN ARC DISTANCE OF 78.11 FEET THROUGH A CENTRAL. ANGLE OF 89 30'33 ; THENCE NORTH 88 25 WEST ALONG THE NORTH UNE OF SAID TRACT 8 A DISTANCE OF 173.34 FEET M THE TRUE POINT OF BEGINNING; SITUATED IN THE CITY OF TUKWILA, COUNTY OF KING. STATE OF WASHINGTON. SUBJECT M AND/ OR TOGETHER WITH THE FOLLOWING RECORDED EASEMENTS: A.F. 8807111069, FOR ELECTRIC SYSTEM (AS SHOWN) RECORDED PLAT, FOR UTILITIES (AS SHOWN) .4 NOTES I. THE LEGAL DESCRIPTION AND EASEMENTS SHOWN HEREON ARE PER A I TITLE REPORT BY TRANSAMERICA TITLE INSURANCE COMPANY, ORDER NO. 0860964 SUPPLEMENT NO.1 DATED SEPT. 10, 1991. 2. THIS SURVEY WAS PREFORMED WITH A LIETZ THEODOLITE AND EDM. - 3. UNDERGROUND UMU71ES NOT SHOWN ARE UNLOCATABLE. W 4. THE PROPERTY SHOWN HEREON LIES WITHIN FLOOD ZONE "X". AREAS 'FW C/) OETERMINED M BE OUTSIDE 50Q -`YEAR FLOOD PWN, PER < MAP 28 D. PANEL 328 OF 6,504, DATED SEP 1 29, W 0 1989. in IrIM DATA: � 0 o SITE - 415 BAKER BLVD. a. Q I Z WA - AREAS - PROPERTY 52.095.3 SOFT. BUILDING 6.4610 SQ.FT. (BASED UPON EXIERIOR DRI NSI(M) � PARKING SPACES (PAINTED) _ 79 j HANDI --CAP- 1 0 UNUSABLE - 3 (FENCES IN WAY) 0 TOTAL - 83 Z 1 Q t0 ., Go -,� CJ 1 30 .4 _ . W IL T- up . me - ,�• T op' ' QR' 14AR'�' .- . SU ILT- UP RODE c . , ,• . yr GvL .. � .. COL. '. .. .: ; , • • _� � ', -, • , -_ : ; •. ..' . , : . � - .- '- •, ' _� , . • .. � .. , ' .. ... ; _« �► _ �. 16TE6L JOIST! • . '" ALL.., SUfir. GEILIhi _n • 1,� _ t�•:! .1 _ ,: s ': r tG - ----- 11" 0� - ��- .. _.._ - fP C 2EE 1w ® 17 Zi► '!i - : 9' PI C'S _ . - 'FLAB INt✓ GOttt►1TlR boLTs . iYP. C� O' - s e N . F6•A' Iwo C t�'AINTI D tt " TOP Of 4 Ub. D" A . GYP. bp.' �. - , ,:: -. •, - _ _._ , . r A ' :�'L:IZ. ~ »= �•' t>�I. tip. lam- _ _ bai.D, . __ Go1�1G..f LAb -- 4 1106 , bAS! bu ILT uP tacooF 44t�,` UAID GOL. GOL . _ _ - - JOISTS L _ T1 �•:� -- STEEL (PA+ 'w suer. '011LINd a G�:'o►. :s; . :. o. A LL • + t , L 1 , •' , GO G DO E _ 1• ) R �1 L MALL !#iKIST r - �qA E b.d.D. ,'et .. �► ,,' �; .:. . , II .� 11 110' � I I �� '� •_ E% =-4 Rub. lSA6 .--- - •o d .r , . r. _. SLOGIC j2 • OIIGT • , .. ,- '; _ �:�: .,.. � LT I! r'ERI !T!R uo PUCT P : = lilC ► T .. -,; t1!�;I��T I l 4 4"(- SLAE►•P1TG1� To pR�►I�I aw ' vRAni MM _ Z7•• 4� -� , ,....... Z9 ... - .. �!- t'EltlM Tea 1 .. - II�SU ' - • . - .I' .__ :.,.PQRI�11Q' INfLtLATIiQN''' _ 0 5 I , 1A•3 - .. - - . _ _ .. ., - - • '.. _. - .:' I�I _ .. .. - .. INEt1L•A� ION.. ' � GoMP'AGTSC� . . ' • - ... . - .. .. � .. . - ... �` 1111$ ... _ • FIIJ. GRAt�E • - - . ... r • . _ � ' . .. :, _ , - .. ,, • : - .. .�. • , • .. -, • - _ _ .. 2 'LAYFrs ol� �.A�a oN :y � y • SACT /0Al Q /4 - G T N "• IZ.I -p� TRI1NSFORMER * SrIITGN GUil64�t s+1� P . - _ SE I o. ..S CA L E . �/� r s �:, �i • . - - i a i �� o PULL Soy( Uwoffsz4Ro NOT! b�✓M GOM . � - - - - - ' •.. . - - - .. ', ...- .. . • . .. - - - . .� • � �= •sciz s • . . is . _; � - o.. .. .. .- . � • ' . : um NRlGAST • • • _ • . • . - :. ' ' .. . • : ., � • • - ' - _ =: _ :. .,. :'. }� - _ . • •CON�R rA0 RoR !<oRM R • . - WITGN CUSICL! 1•URNISNED 4- INSTALLED A ' F�ta/!R co. G.tNeRAL GvwT ToR ' - ' °' • " _ ! "1'n VlRll� GrcTENT OF NIS Wb171CAowOa o. _ Itv -4: ,..., - , II ,{ -a .� •iO 3 a -O -� 3. a Z a a 4'- 0 q - 4 ► a t . .. _ 3 Id 3 4 b .� �� - =- - ' . •_• .,• _ . •• - - - - Lr - STAIR B 8'. SUP E.1. 5 P r -r ; _ M A - TAT 8. .. .,: I •., -., _ � - Z07 _ , _.. :, .I V. 1 MS N F• E tJ T'EL.E 1 _ 1:18• t + _ I o w . 1 'I • F 1 7 V ep - • 1_ r, -'' . r. •, E T . : L• 1 1 ir MOVAl3L6r. PARTITIONS 1J.1,G. - :,. .�, t �9 1 0 1~4 A i+ t I'I4 _ r NAIL ---�L " L I _ .+ - W ,� t ESS+ i !i1De1VALK - - :-WO MEWS - 1 r � M T - W • M �• I �i I O G _ . PA T 1!R>f T I i I I _ : ,' � e•, • � fotttld!• XLASN r _ _ T � •{ z I •t 3 t I 00* - - _ _ >- .. 4�Z�h,. � Y �•- _ ='�o s. `ear:•.: �• .�_ �;.• '�_1 t__.1• :L 1 L.1 � - _ . COL. Ht r t, i - + -• a - I ti G O AC C. A r /J u ny Q clot _ s .1�OF . _ _ ,- . �-.' W.W. F. I '1 - -- f r' I `T F . i 1 '. .I r - f • _ . , -:, _ ..: .: • •1: I `I� I t I L-U et N_ - M. ... .. • t 1 , l I r 1 �, I . t . I t _ : H.P. fiC10f• .: -1. l .� t _ f _ I . _ . - I E 9a' �4 EL.2�4o 4or ti i - i r - •+ NIC I 1 [Q �_� L�. L_ � �. •.. _ f_ - z '•=`j ';f D •r _ c : L_:1 L:. J- '1:�:� L_ -! , L'' I ,. c NTT+tAI•�Ct'. ALL. D K N LJ 1 TC Trl >_ W • O" KS VA U AT N R :- R14i r • ..._ R. t _ -, o1i. - i r FIN. RLR. EL. 8.40 ti T` 3I b L ' fe 10 -=S'� . 9 s' I ( !. I - 1•'•. ! 1 1St — — - IL 5 - - I I _I I '� f I -- ;, _ ••:- -, _ ..;, - •�_' � - 1- 1 _1 '� I I• 1 - bw -• _ �' A "�I' - • •� _ o - - _ , _ ,' 204 'Cf: i� _ .. z 1 ,• :� G E W E RA L O F F i [ E o v :.• .. :�- : :.R _ _ _ i .. �; •• , - - - � r• _ ..:: - - :�•• ,. � -� -#, � _ - SLOPE ,- SLOPE F _�. _ '3 0 _ • � � _ = FIN. LR. 4t? .. r r i r J t _ t t►--- 1A - i _ 1 - - - • I t - � :• -- . ��': . _ .. - - - � - ,FLOOR EL-2 S.Z4 _ GotrF• �Cd.S G F o _ r I - 1 _ - I t -1 - I . • t - � t - . , ;- . _ - ' .��- -� , - - 29 : . - • I. I ; •I . • I . • WW _• Y � � n I s I COT. • I t I i I I i ) I iRlw E - E IE C OL. L _ 1 L_J L -..! =�_ I _�! L 1 �L _1 L__i L_! 'o• . I , •� _ _ I _ L '.J L_ 1 L__ i L __I L _ 1 C.� - I •��: _ r M r «o tac - _ - - r - - - - - ' Z� �Z� c oc . _ :7 �9 =--e- Writ: EVALUATION AREA 15 I = DRIVE TNRU DAMAGE r -� t- -� ' - . #- r --� «- f' f *": - _ _ . - - , - - s t T *STIMATIQO OWW. NO PARKIN& l 1 i - ! ! : f _ HALL I REPNIRallo OR STORAbt PERMRTED. . fF =t - 1 I I I I_ I I I 1 [ s 24 ; _� b •rls I I l j I I I 1 �= N:P i Ql��• i • - - . 1 *: 0 34 12� • 3. L.2A.40-� 40 L 1 L_'1' L' _J L_ 1 - -_ 1 L 1 1 ��� L;_1 22 -4 7+4' -Sr Z'1'•4 _ ': 1 1 • _ - - /'• - _ '1�• L• ,' - -• ',• -•' • - - - •= - . - , MWO *Li�.TRIG. IPLAl11 • I. _ _ ,- - -_ - t ! L - O -� , r _ _ _ _ a_ _ _ _ Y s _- • - �: I�OR- - CEILING -�iR1D MItTTERIr ; t MootD - E,5 i •'' 1 r 1 t- Z l r T r ` E r : �` =�� s '� _ _--- : �= -- .r - raft W& • _ ' I - I - I � 1 I 1 1 , ;, :. _ -.. - - _ _ '',. , _ _ �•- -' -"" -� - I 1 ! 1• 1 , I -t' • � �• - - .t - :' - RECCE �' i 0'%l � t - � I• . � , � - , , r � � t i 1 a'� -4� A -O Z -S •0 9 -O -, L + i �� _ - 1._ _•'_ _� 1 - _ 1 a Z ` �•8 -0 3 L _1 L_J L_ l_ �_� t.�J �_� ;, L_� L_.� L_J •.,� :_ _ _ •; L_ L_� �._� t' L.� -j : - ? 1 2' 4j REFEit T4 EL�LTRfG "rLA1�1 - • _ "R +� _ , .. • - _ - = ! - �- - f G�iiG11 i�pr►artp qi ' . _ t I 1 ! - _FOR CALM&.' &RIO ftT'rEbN -•: - .. - _ _ _ iAIItT iN _ T • - - - 1 - -� _ "- - • _ - _ • - : _ _ • ' _� - , Y _ •• M .• �. • _ •� ` � i l •- � � - '• j 1o' -gam' � 1 I•T" I � � • �'•�' _ " �+ ` ' � -. f �- 1 i I r 1 r- -� _ i ' , r , T' , - - _ ' - r r - _ �- - -, - - 1 - -= _ 1 �+ c o Jr C 4, 4 1 110 _' • = ;� vYV ! V. F. r� 1 • I : I I - TAI _, �� ' ! I I f 1 I I t :£ N T RY [ �� I R '�� L_ - L i _�-_1 t--;� . L_-� :.L_� L_� L_� Lis L_.:, 1 - - 1 _ . ' :__ L_� L__� } __� -' L_� '� D21 �: ! - -. _ .. ` - `' � � • � - 101 _ no - '• _ _ - 1 = • ♦ f PtANT SPA C6 �-�• PL4ivr W44 d 4r 4' -S' 4 3' ALdf 3L4• , 4L>b V-4 r • v- - .. ...,.ter , t , TN+5 VRAw r 1&j 1S QE E Vi5o E ` - _ - •- - _ - - •- _ A 5voERCEQF COp�£S 15SUE7 n4 i c 2 -o LATEST ;?EN11510 N C 01V 40 - aF L O O R 4 A IV - SC A LE A /t o w t - _ _ - - �IR S 1 ,t�" L 0 oR X f A A � I� 1 PC V - l c �� Fc:A tw--, .4 _ . _ _ - `_` ., ,. -_ -.� - _ .:•: - `- • A�dr?EVI-AT10N S 4 yY%+1b0L5 - = - _ - t ' - , _ L . • . .. - war w GONTRSLT iVOiLK ' ft. GUMT I ON Xaft. +_ "m1 &ftATW /MRTITIa1 To OF PLOD! _ -- •- i _ _ C01�11G_ _ FOR woo "MI". V ca ow m 0amm sew ftuft Penn P400TIM Cm sea= jhw uffraft Abm mot _ _. .. - _ •�_ : �- _�._� - _. �.� _ ., ` •► ` � _ ' 1 . - - •�� : . fj • . \. _ �►� - �ri�F � � ` _ ` .� . + • r i- � . !_ - w , � ' . _ •. �_ y, - f - .� {/ ... � � • � _ � _ _ _ �► � w._.1 +r_ .- _ .rte. -►�.. ' _, " ,� i - ., . w_ �irraL< �`�• .. . � w -i � . _ ! _ . w _ _ `yt� • _ _ ` _ ., _ � a e•.' _ o - . - - - - I� 1 PC V - l c �� Fc:A tw--, .4 qb f , SID ' if '�. - '' ••l�l�t•�tt•• � ti+R ta TER , IL 71 � . , IS :O .r.1 ;• - . :`I• ; = � �, ' 1* POP RIVETS de 4AI L ; • . VALL . "4 DE. G SPACE. AT ALL ��. �• ' .. ALL MUrtODCaS Cv•'C WAL ,,. i '` 4 j_ , V.,,jrR5 AT OvpOS I tp WALL VERTIC STRUT PCIt U.n.C. ,7t 1C 1 P)q5. COMP4tlovr PER P1.CNUM A)EPTII. Y 1 2 c.>tcr!► w61cm k s :: 4 4 ' • � M 2e wive ivkllw . 110� w4 Ir dr" I 'off • IJ w Alk Go a�. eta ' MJAV It. to" "%" I0i4 jrAt e Q VUb h1AI t i p so • •• • • .♦ • •• • •• ••, .� •• r ♦ I V r I I I •I • • , ' t , 410 AT MAIM IRV4W. R W-DO" (J.C- (Ory cw MINIMUM OF • G zc a Zys A.1E 1` �' k oV �TrG h Wu+►lr1KCT Q •� M �; • ,Y' ''. •:,� ,, �.� •�' �• ---'�' 1 c AVGE s ptJ►YE O e+u►Cti�' wtRls . •K .s t VMP 94kL.L.. ..« ,,,,1`_' , - •i� r ��• J• -• �' • /'+ .�..r•+• • . • (NOTE 1 1L2 ) mod • wr :L _•. t .'• fir..i vp 0 , .: , : �. • ,,;.; r .�;�.. �•; .. .. . • ; ,+ . ', 1 Ji.- t ih� p f7 1,1 Ai 1 �� 1 � 'TEE f:0. v ' ' .:�' =x•1.,:,1 -, r im JI M u •1 ;j IP *v (AV N ga 6. 4w Sit few W_ top ,.� - �. _ +•.•..�- _. w —w_ -r �_ -w.. �� `- r•rrw _ .�.. . _ ._ �� ,•t •nr.. _. 4�- .. .. r _ r+M r r _ • ..• •� . -• t ` i I' I f / + I I - - s . ti ,� Y • .�nR -� 1 H 1' r , 1 r i , 01"elA OLva RIP p,r r• r. r rl +r r r r.rr irr•+r.rr•r rrr • Itr�r r�lrr �iw BAfi 'L'r : Ki eft^ �v,q t%tiO�R V41 .,• IZ. .i`.1& Fvft V 10 � repipi T e a� u1�w UF 1�r 81 : - ' ' � . : ' • �,�,,3,4,g,� . • 3 r< fl g. L. � � , ..:�, � �Ah -s�, 2 PPS•• .. . ' , Im PONSsdl M Marc." ID i• a wIraw twa al VOLAW 111i ' lime l 111 M an M . 00011101 w RtfO y li0�i�>t 7 :L I, �, °j(8 ti as vvod mt:;� rwt' a, 2 M. wIrl� i►t .!_ • W Mn low •t s 1 �uTT , I.�c- �:.•;�~T' l 1. v�R 1 1[`.�.�), I -1/1 1- ��T�P; W1'"' un WAM = fit! iii M "to Ina • A off" ar f �. 1 !M •!0 A!t 10 w 1'R #01" M motilMt ' • l�Ct 01100011411 am A Btu M 211416111116 MT 1 1 - M'wsw Im 10l11M M 224.601 pw !i0 l! W� LM 1p / 3 �° ��.G. lip t P. FtStAt E Z law • s • • • K LK F'LATf� � L►�L� `. OIW Isom Om h er a Wt At�rtw an war L= A DI rat w I SO. " vM9 , Isom MM • Mi� " M am NONSO • &am SO $6.00 N we Bc gloom w "Oil A CMIUL An" GO 010162011112168 ' 10 � 41 •r .rr! ARM = �11 LM a SAN sit • • 0t li r 298.06 pw 10 Un AMR MM M 01111�1111t G 0x ISTI r•ics :Tc. y+�/ /��,��,r�� F..xry it; H • t-'f71. -• GAS - 40M : U�. W (M161 bfi6-0 4 WILT AX U06, ' &11 1 100k. &WL*JP PUZA S, cAAS raP. (ZOEPI 4-w- WMM umpw -m* M% mft) DUI Ld �� '� � �- N � - . , . : • . wW -Sl"G' WALL - xi t X11 -�•:ri =�c� C� t►•�LL W4 4")P 6 A-L qlb u1J M RSA Oft �� ' W F O*f 7 Z I } I 1 T� '► N•JD CA RY WALL So _r C"r I 1 I = ` _'" � - - Exfw11� kP416 74 iE D1`MGt.ISN E A _ -� A tw} I I Ov PIJMXA O JTLZT 'O 1 • M 1 ', O I �'- M I'�' 3� CO 10 O 0 o V ar �'� 1 �I•�CW W I u D+o�� ' yI LLr �: Cvl Er is r y =DAFT oil ! 8 O ` AFF, ! • • L-4 IF s - F L OOK - • �-� _. _._� _ �....�..� �..�. �_ - __ •� -� w. - +..�• ----� _� � s �+ _•••• S .. •- _� ... - � J•i� .. .f• i — � •�. � � : t . �. ♦ �r _ .► .► it •..� -.+• �qq!`• 1 _ ) - q c GENERAL NOTES 1 THE WORK INCLUDES THE FURNISHING OF ALL LABOR, MATERIALS, EQUIPMENT AND SERVICES NECESSARY FOR ANY REASONABLE INCIDENTAL TO THE COMPLETION, IN PLACE, OF ALL WORK AS ILLUSTRATED AND DESCRIBED IN DRAWINGS AND REFERENCE SHEETS AS PREPARED BY THE ARCHITECT. GENERAL CONTRACTOR IS 70 COORDINATE THE WORK OF THE HVAC, PLUMBING AND ELECTRICAL CONTRACTORS AS REQUIRED 2. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS SHOWN ON DRAWINGS AT THE JOB SITE, AND SHALL NOTIFY THE OWNER IN WRITING OF ANY OMISSIONS, DISCREPANCIES, AND /OR CONFLICTS BEFORE SUBMITTAL Of BIDS OR RESPONSIBLE FOR SAME. 3. DO NOT SCALE DRAWINGS, DIMENSIONS GOVERN. 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SECURING ALL REQUIRED BUILDING PERMITS AND FOR INSURING THAT ALL WORK CONFORMS TO APPLICABLE BUILDING CODES. 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL FIELD DIMENSIONS AND PROPER INSTALLATION OF SAID WORK. 6 THE CONTRACTOR SHALL REVIEW THE DRAWINGS FOR ANY DISCREPANCIES AND SHALL REPORT ANY SUCH DISCREPANCIES AS MIGHT BE FOUND TO THE PROPERTY MANGER PRIOR TO BID AWARD OR BE RESPONSIBLE FOR SAME. 7. WHERE SPECIFIC PRODUCTS AND MANUFACTURERS ARE SPECIFIED, THE CONTRACTOR MAY USE AN EQUIVALENT, IF APPROVED AS SUCH BY THE PROPERTY MANAGER IN SUCH CASES THE CONTRACTOR SHALL SUBMIT SPECIFICATION SHEETS AND SAMPLES AS APPLICABLE FOR THE OWNER'S APPROVAL PRIOR TO ORDERING 8. THE GENERAL CONTRACTOR SHALL HAVE DIRECT CONTROL AND MANAGEMENT OF ALL CONSTRUCTION MEANS AND METHODS AND BE RESPONSIBLE FOR THE SATISFACTORY OVERALL PERFORMANCE OF ALL HIS SUPPLIERS AND SUBCONTRACTORS AS WELL AS ALL ASSIGNED CONTRACTORS IN ORDER THAT THE ENTIRE PROJECT BE COORDINATED AND SUPERVISED 9. ALL GYPSUM BOARD PARTITIONS AND FURRED WALLS SHALL HAVE CONTROL JOINTS AT 30' -0" O.C. MAXIMUM. 10. ALL WOOD STUD AND /OR WOOD BLOCKING TO BE FIRE RETARDANT TREATED TO MEET RATINGS IF REQUIRED BY LOCAL OR STATE CODES. 11. ALL INTERIOR PARTITIONS TO BE FABRICATED OF METAL STUDS SPACED AT 16" O.C. AND 518" GYPSUM BOARD, FIRE CODE "C" UNLESS OTHERWISE NOTED. 12. GENERAL CONTRACTOR TO TURN OVER THE PROJECT IN COMPLETE OPERATING CONDITION IRRESPECTIVE OF WHETHER THE DRAWINGS AND REFERENCE SHEETS COVER EVERY INDIVIDUAL ITEM IN MINUTE DETAILS. 13. ANY COSTS INCURED BECAUSE OF CHANGES MADE BY THE GENERAL CONTRACTOR WITHOUT PRIOR WRITTEN APPROVAL FROM THE ARCHITECT'S OFFICE OR HSBC, WILL BE THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR. 14. THE INTERNATIONAL ACCESSIBILITY SYMBOL IS TO BE PLACED ON THE ENTRY DOOR OR ON THE GLASS ADJACENT TO THE LATCH SIDE OF THE DOOR. THE SYMBOL SHALL BE APPROXIMATLY 6" SQUARE. 1 1 GENAERAL NOTES No. DOOR SIZE REMARKS DOOR MAT. JAMB HEAD REMARKS 101 _ ENTRY DOOR 1 FLOOR STOP SIM TO A ANOD ALUM. 11 PR. HINGES 1250 PROVIDED BY LANDLORD 102 3' -0'x6'- 8'x1314' C F.P.S.C- 7/A -1 SIM TO 7A-1 103 3' -0'x6'- 8'x1314' -_ C F.P.S.C. 71A -1 SIM TO 7 /A -1 144 Y -0 8'x1314' B F.P.S.0 7/A -1 _ SIM TO 7iA -1 105 EXISTING EXIST. - - - 106 EXISTING EXIST. - _ _ PROVIDE PANIC RELEASE DEVICE [ DEVICE 107 EXISTING EXIST. - _ _ PROVIDE PANIC RELEASE 4. NO THLA%f8 LATCHES OR KEYED CYLINDER DEAD BOLTS ALLOWED ON ANY DOORS UNLESS OPERATED BY A SNG..E ACTION WITH LEVER 5, MANUALLY - OPERATED EDGE OR SURFACEA40UNTED FLUSH BOLTS AND SURFACE BOLTS OR ANY TYPE OF DEVICE THAT MAY BE USED TO CLOSE OR RESTRAIN THE DOOR OTHER THAN THE OPERATION OF THE LOCKING DEVICE SHALL NOT BE USED AND ARE PROHWED. 2001 CBC 1003, 6. EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL EFFORT- NOTE: DOORS TO BE STANDARD 6'4' WITH METAL FRAMES CL NEW DOOR EXISTING DOOR EXISTING DOOR TO REMAIN TO BE REMOVED q DOOR SCHEDULE Q L W" 18' SIDELITE 1/4' TEMP. GL. 1/4' TEMPERED ALUM. FRAME F.P.S.C. F.P.S.C. GLASS G.C. TO INSTALL MAIL SLOT ON HINGE SIDE A b B C� 6 ' 1. F.P.S.C. =FLUSH PANEL SOLID CORE. ALL DOORS TO HAVE METAL FRAME 5 DOOR TYPES ONE LAYER 5/8' TYPE 7C GYPSUM WALL BOARD APPLIED AT RIGHT ANGLES OR PARALLEL TO EACH SIDE OF 3-5x8' METAL STUDS 16' O/C WITH 1' TYPE 'S' DRYWALL SCREWS 8' 0 C TO VERTICAL EDGES & TOP & BOTTOM RUNNERS B 12' O/C TO INTERMEDIATE STUDS STAGGER ALL VERTICAL. b HORIZONTAL JOINTS 24' O/C EACH SIDE TO THE BOTTOM OF CEILING. �weuj Tp 3-518' METAL STUDS 20 GAUGE STEEL 3 I NON -RATED PARTITION SCALE.- 1J8"=l'-(r 518' GYP. BD. H.M FRAME ANCHOR PAINT P2 3-50 METAL STUDS PER MANUFACTURERS 20 GAUGE STEEL SPECS. I j L J I I I I I i I I I I I I 1 SILENCERS (3) MIN. DOOR ---� HINGE WOOD BLOCKING 7 METAL JAMB DETAIL (TYP.) l o t� , i ) M!; 7 DIMENSION PLAN +- e._. a.�.r -�..__ ��- � ... w_ � -�.�� ... r. :-_ - ,.- .�..��- �. -rte. +ter .�- �. ��.. _.���__. _.._ _� -� .. � _.,,.. � �.- a._ _ �.. � -..�. ��.. -.� '�� ...a..�._� � w . � ��.. _ _..rr..r .�.- "...w A.. �-�� -.+ �� `�•�i .�.- r'.�• �- ��_ SYMBOL DESCRIPTION REMARKS EXISTING PARTITION TO REMAIN 11 PR. BUTTS 88 1279 6/8' GYP BD ON 3-518' METAL STUDS @ 16' O.C_ TO BOTTOM OF SUSPENDED CEILING. --- ------ EXISTING PARTITION TO BE REMOVED NOTE. CONTRACTOR TO VERIFY ALL DIMENSIONS IN FIELD. 2 IPARTITION SCHEDULE GROUP NO. DESCRIPTION REMARKS 11 PR. BUTTS 88 1279 1 1 PASSAGE SET 93968 SERIES F10CSV SATIN CHROME SEE NOTE 2 CLOSING 1 FLOOR STOP 11 PR. HINGES 1250 2 1 PRIVACY SET 33975 SERIES F40CSV SATIN CHROME 1 FLOOR TOILET STOP 1 DOOR SKIN 3 11 PR. HINGES COMMERCIAL GRADE SATIN CHROME 1 LOUNGE PASSAGE SET 93968 SERIES F10CSV SATIN CHROME 1 FLOOR STOP 4 HARDWARE TO MATCH EXISTING (BUILDING STANDARD). VERIFY W1 REAR ENTRY LANDLORD AND CONFIRM W/ BENEFICIAL PROPERTY MANAGER 5 1 CRL MAIL SLOT MS125A HARDWARE TO MATCH EXISTING FRONT ENTRY (BUILDING STANDARD). VERIFY W/ LANDLORD AND CONFIRM W/ BENEFICIAL PROPERTY MANAGER. HARDWARE NOTES: 1, FINOES SHALL BE CHROME OR POL&U CHROME 2. G.C. TO VERIFY HARDWARE IS IN COtiPLANCE WITH ADA. 3. EXISTING HARDWARE TO BE REPLACED AS REQURED. 4. NO THLA%f8 LATCHES OR KEYED CYLINDER DEAD BOLTS ALLOWED ON ANY DOORS UNLESS OPERATED BY A SNG..E ACTION WITH LEVER 5, MANUALLY - OPERATED EDGE OR SURFACEA40UNTED FLUSH BOLTS AND SURFACE BOLTS OR ANY TYPE OF DEVICE THAT MAY BE USED TO CLOSE OR RESTRAIN THE DOOR OTHER THAN THE OPERATION OF THE LOCKING DEVICE SHALL NOT BE USED AND ARE PROHWED. 2001 CBC 1003, 6. EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL EFFORT- 6 HARDWARE SCHEDULE CAI L%d#n"_.:t L W •l�r UO z Z LL 0 Go J — LJ Y Zm� L1J Lc) � F-- .o U° C/7 a �o W .p � " a a. •- o it O r� .0 0 = PA6 M Q L u 0 �� =a 0 0 6 6 Da. = 2 .CI a 2 �N FC b .�i f v u F Z I I�;� il�I ' Iif •� 71 I a_ l W J W 2 U Z Q J a Z 0 C!1 J U) z — LU Q ,�. LLJ 00 Rev,,iam 0 r, M?Ltt.,TiC I Jc r • -6 4 sw ::Mp. ' 1I'- 0— k..r S. f«► air aw= agk1'MCFS Y - -OWL • %A a 're sTftjGTLvRcs 4m et at 9�AhC!- s slaw BI► C>A�1: 9s 05�2208 AA S� 5� .� A4 H.V.A.C. NOTES ALL HN.A.C. EQUIPME E TO BE REUSED 1. HEATING, VENTILATING AND AIR CONDITIONING CONTRACTOR SHALL FURNISH AND INSTALL ALL DUCTWORK, DUCTWORK INSTALLATION, REGISTERS, GRILLES, DIFFUSERS AND TERMINAL BOXES 2 HEATING, VENTILATING AND AIR CONDITIONING CONTRACTORS SHALL FURNISH ALL EQUIPMENT TEMPERATURE CONTROL COMPONENTS AND ANY SPECIAL MOUNTING OR SUPPORT PACKAGE. 3 HEATING, VENTILATING AND AIR CONDITIONING CONTRACTORS SHALL INSTALL ALL H.V.A.C., EQUIPMENT. 4. ALL WORK TO COMPLY TO LOCAL, MUNICIPAL AND NATIONAL HEATING AND VENTILATION CODES. S. CONTRACTOR TO COORDINATE ALL WORK WITH THE RESPECTIVE TRADES AND VERIFY LOCATIONS FROM THE ARCHITECTURAL DRAWINGS AND FIELD MEASUREMENTS AND SUPPLIER SHOP DRAWINGS, 7 OBTAIN AND PAY ALL PERMIT AND INSPECTION FEES AS REQUIRED FOR THIS PORTION OF THE WORK 6 LAYOUT IS DIAGRAMMATIC AND CONTRACTOR SHALL INSTALL EQUIPMENT AND DUCTWORK TO MEET THE FIELD CONDITIONS AND PROVIDE SHOP DRAWINGS AS MAY BE REQUIRED FOR THE WORK 9 ALL DUCTWORK CONSTRUCTION SHALL CONFORM TO LOCAL CODES AS WELL AS A.S.H.R.A.E AND S M.A C.N.A. CONSTRUCTION STANDARDS FOR LOW VELOCITY DUCTWORK CONSTRUCTION AND NFPA 190-A. 10. BRANCH TAKE -OFFS SHALL HAVE SPUTTER DAMPERS OR MANUAL DAMPERS FOR ALL SUPPLY OR RETURN AIR DUCT BRANCHES. ALL MAIN BRANCHES SHALL HAVE MANUAL DAMPERS. 11. UPON COMPLETION OF INSTALLATION OF VENTILATION DUCTS, CLEAN ENTIRE SYSTEM OF RUBBISH, PLASTER, DIRT, ETC. BEFORE INSTALLING GRILLES OR DIFFUSERS 12. AFTER ADJUSTMENTS HAVE BEEN MADE TO THE HEATING, VENTILATING AND AIR CONDITIONING SYSTEM, THE HEATING, VENTILATING AND AIR CONDITIONING CONTRACTOR SHAH BALANCE THE AIR DISTRIBUTION SYSTEM, SUBMIT THREE SETS OF DATA OF THE TEST AND BALANCE TO THE OWNER FOR APPROVAL. 13. ALL NEW DUCTWORK SHALL BE LINED WITH 1' FIBERGLASS ACOUSTIC LINING, CONSTRUCTED PER SMACNA STANDARDS, STANDARDS, MAXIMUM S-T FLEX DUCTWORK ALLOWED. 14. PROVIDE FACTOR FABRICATED TURNING VANES IN ALL SQUARE TURN ELBOWS. 6. CONTRACTOR TO VISIT THE SITE TO DETERMINE THE FULL EXTENT OF THE WORK AND FACILITY LOCATIONS AND VERIFY WITH GOVERNING BODIES. � GENERAL NOTES RECEPTION i 15. PROVIDE FLEXIBLE DUCT CONNECTORS BETWEEN DUCTS, FANS AND AIR HANDLING UNITS AND ALSO IN DUCTS CROSSING BUILDING EXPANSION JOINTS. 16 NO GRILLES WILL BE INSTALLED IN ANY DOOR NOR WILL UNDERCUTTING OF ANY DOOR BE PERMITTED. 17. PROVIDE MANUAL DAMPERS AT SUPPLY GRILLES. 18. PROVIDE MECHANICAL VENTILATION IN ALL ROOMS CAPABLE OF SUPPLYING A MINIMUM OF 15 CUBIC FEET PER MINUTE OF OUTSIDE AIR. 19. G.C. TO COORDINATE WITH SPRINKLER CONTRACTOR ON ANY ADJUSTMENTS TO EXISTING SPRINKLER SYSTEM. (IF APPUCABLE) VERIFY ALL EXISTING CONDITIONS AND AS NEEDED 4l P... 4e�" 3'�be az4d�c� � 1�� -2?d V �fv MAW � REFLECTED CHUNG PLAN I se " �4r • 40 SYMBOL DESCRIPTION SYMBOL DESCRIPTION I ca EXISTING 7x4' PRISMATIC 4 BULB FLUORESCENT FIXTURE I SINGLE POLE SWITCH ( +4' -0'AFF} r HONEYWELL'MAGICSTAT' PROGRAMMABLE THERMOSTAT *C T 3200A 1001 OR EQUAL. �-� 2'x4' PRISMATIC 4 BULB FLUORESCENT FIXTURE (1) TUBE OPERATING AS A NIGHT LIGHT. I - COMBINATION EXIT SIGN 3 EMERGENCY LIGHT COMBINATION LIGHT! q1T 0 Z T- EXHAUST FAN (TOILET ROOM) z TYPICAL SUPPLY DIFFUSER WITH MANUEL DAMPER i u 2 - � 2 - RATED FIRE EXTINGUISHER W TYPICAL RETURN/ L i.. co co EXHAUST GRILLE a co w J LL W— Y w j Z W Z m 3: L 2 FIXTURE LEGEND r L7 th co CA) EIIIIIIIIIIIII d C d m 00 o c " 40 LL o. S �o W ��� cle po0• toy a� Z »IW. LAJ . O 0 = 00 46 CL a 2 a - I FZ1 Revi O sims O O O O 1 Pr R1RC . T i i F M 41C1■1.EX& Sma :31P w - 4iL_ , k_. S W-!:t-L +'C'46 MC - - - -ow. • I" qp a re sTft.1Gvwws 4K: RJt 74wt OP4*0- ! Gas sore �t AS 110111D + ilk 05�2208 amp* Is ca Z W UO q1T 0 Z T- z Q u W L i.. co co a co w J LL W— Y w j Z W Z m 3: L W � = W w im qqr H W j 00 o c " 40 LL o. S �o W ��� cle po0• toy a� Z »IW. LAJ . O 0 = 00 46 CL a 2 a - I FZ1 Revi O sims O O O O 1 Pr R1RC . T i i F M 41C1■1.EX& Sma :31P w - 4iL_ , k_. S W-!:t-L +'C'46 MC - - - -ow. • I" qp a re sTft.1Gvwws 4K: RJt 74wt OP4*0- ! Gas sore �t AS 110111D + ilk 05�2208 amp* Is 1 ALL FLOOR SURFACES MUST BE SMOOTH AND LEVEL, FREE OF DIRT, WAX AND OLD ADHESIVES PATCH AND FILL CRACKS AND DEPRESSIONS WITH A LATEX BASED FLASHING COMPOUND SUCH AS LEV -L- LASTIC OR SIMILAR FOLLOW WITH LEES EVERSEAL FLOORING SEALER LEAVING NO G IN THE INSTALLATION CARPET SHOULD BE CONDITIONED ON SITE AT A MINIMUM OF 65 DEGREES F FOR 24 HOURS BEFORE AND 48 HOURS AFTER INSTALLATION VERIFY MATCH BETWEEN DYE LOTS INSTALL CARPET IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS AND THE CARPET AND RUG INSTITUTE'S INSTALLATION STANDARD, CRI 104 MAKE CUTS STRAIGHT, TRUE AND UNFRAYED CUT CARPET FOR TIGHT. NEAT FIT AGAINST WALLS, COLUMNS, PROJECTIONS. AND EDGE STRIPS WITHOUT GAPS REMOVE EXCESS ADHESIVE FROM FLOOR. BASE, DOORS. AND WALLS WITHOUT DAMAGE CLEAN AND VACUUM CARPET SURFACES PROTECT TRAFFIC FROM CARPET AREAS FOR 24 HOURS AFTER INSTALLATION CARPET SHALL BE TILE SIZE WITH REGULAR BACKING NONSTICK CARPET SHALL NOT BE USED 2 ALL. WALL SURFACES WILL BE SMOOTH AND DRY WITH NO IMPERFECT IONS BUMPS, ROUGH WALL JOINTS AND OTHER DEBRIS ON THE WALL SURFACE WILL NOT BE ACCEPTED. ALL WALLS WILL BE PRIMED WITH SEALER PRIOR TO WALLCOVERING OR PAINTING 3 ALL GLUE TO BE REMOVED FROM EXPOSED SURFACE OF WALLCOVERING AFTER INSTALLATION STRAIGHT AND UNDETECTABLE SEAMS ARE REQUIRED, THE DOUBLE CUTTING METHOD OF INSTALLATION IS RECOMMENDED CUTTING THROUGH THE DRYWALL WILL NOT BE ACCEPTED AND WILL RESULT IN THE CONTRACTOR REMOVING THE OLD WALLCOVERING, REPAIRING THE WALLS AND BUYING NEW WALLCOVERING AT THE CONTRACTOR'S EXPENSE 4 PRIME WALLS AND TRIM TO BE PAINTED WITH ONE COAT OF ALKYD PRIMER SEALER FOLLOWED BY TWO COATS OF LATEX PAINT PER SPECS. BEJAMIN MOORE OR SHERWIN WILLIAMS- GENERAL NOTES A PLASTIC LAMINATE STORAGE CABINET LOCATED ABOVE TOILET SHALL BE MILLS PRIDE WALL BRIDGE CABINET MODEL #OJ2428CC WITH CLASSIC FINISH DOORS. B PROVIDE "BLANK' COVER PLATE(S) FOR EACH EXISTING ELECTRICAL AND PHONEJDATA OUTLET NOT UTILIZED PER NEW CONSTRUCTION. 1 1 GENERAL NOTES SCALE- LOCATION FLOOR WAILS CEILING COMMENTS ARCH. NO ROOM NAME MATERIAL L FINISH BASE MATERIAL FINISH MATERIAL FINISH HEIGHT VCT -1 #51803 PEARL WHITE 232 S.F. USE SABLE BROWN - LEES - FACILITIES N/A C -1 #301 HEMLOCK 158 S.Y. B-1 I.F. CERAMIC TILE 101 WAITING CONC CT - B1 GYP. ! . WC1 ACT1 - FISSURED 10'-0" SEE HB1 102 RECEPTION KOROSEAL - ARCADIA Cl ARMSTRONG-STANDARD GLASS/ VERIFY WITH PROPERTY MANAGER IF EXISTING FLOOR COVERAGE TO REMAIN VINYL COMPOSITION SEE H81 103 CLOSING 1 GLASS/ GYP. BD, I LINEN ' SEE HB1 104 _. CLOSING 2 ARMSTRONG STANDARD SHEET ---� GYP. GYP. BD. NIA VINYL/LINOLEUM G.0 TO _ SEE HB1 105 MEETING I GLASS/ GYP, BD JOHNSONITE #80 FAWN 1i8" ` T SEE HB1 106 SALES ROPPE #140 FAWN 1B' VINYL COVE BASE, 4' H GLASS/ GYP. B0. TS1 ROPPE #177 CARPET TO HB1 TRANSITION STRIP NIA TILE ADAPTOR COLOR: #140 FAWN CARPET TO TILE ADAPTOR COLOR: #80 FAWN LEES - FACILITIES #224 SEE NOTE #1 C1 (ASTM E 648 )CLASS 1 INTERFACE CARPET HOUSEHOLD 107 MANAGER FLOOR SEALER: CARPET (ASTM E .662) 450 SYMMETRY #4295 GLASS/ GYP. BD. INTERNATIONAL,. I LEES- EVERSEAL (ASTM E•84) DSI - KOROSEAL SEE HB1 108 O LUNGE VCT1 (TUNNEL TEST) GYP.BD. P - 1 SEE NOTES #2 AND #3 VINYL WALLCOVERING FLAME SPREAD: 10 SYCAMORE 54" w/ NO 1. ALL PERMANENT ROOMS WILL REQUIRE ADA COMPLIANT SIGNAGE. ROOM DESIGNATIONS TO BE PROVIDED BY THE BENEFICIAL GENERAL CONTRACTOR. 2 ROOM FINISH SCHEDULE I SCALE- cp i FINISHED FLOOR 4" VINYL SEE SHT. A-3 BASE 6 I ELEVATION @CLOSING ROOM SCANL_c - I - 2.''X 3v L Aoil - ap -f Q _ E� �m 5< O •� F -" RECEPTION ,02 At WAITING 1 o, CLOSING I F CLOSING 2 KITCHEN ELEVATION FM RE / F I N ISN 7 8 sc^l ^^"r►'�"- +�.- ...�- .�-.--- '.�..r�-. sue-.- --�" .► .. -�. .... -- ..fw. -..,. ,. -�.�- �. �. �...- ..�...- -+•• -v +�.... --�_. _ .•-'�- _ ..- _ - �. DIRECT GLUE DOWN CARPET CONTRACTOR TO ADJUST FLOOR LEVEL AS REQUIRED TO PROVIDE FLUSH TRANSITION RUBBER ADAPTER STRIP (JOHNSONITE #CTA-40-H) VCTISOLID TILE 3 I INTERIOR THRESHOLD CODE DESCRIPTION QUANTITY AMERICAN OLEAN- SELECT CT -1 PORCELAIN TILE - #SL 62 S.F. DESCRIPTION *ALMOND'. 17028 OR 18608" PROVIDED BY: INSTALLED BY: ARMSTRONG-STANDARD EXCELON, VCT -1 #51803 PEARL WHITE 232 S.F. USE SABLE BROWN - LEES - FACILITIES N/A C -1 #301 HEMLOCK 158 S.Y. B-1 ROPPE #140 FAWN 118" CERAMIC TILE VINYL VINYL COVE BASE, 4" H 352 L.F. BASE CONTRACTOR ALTERNATE HYDROMENT #627 -327 TS-1 MERCER #152 CARPET TO TILE 19 L.F. TILE A155-009 "GOLD" 12"x12'. ADAPTOR #201 BROWN WC -1 KOROSEAL - ARCADIA 317 S.Y. ARMSTRONG-STANDARD A421 -04 SYCAMORE NOTE: VINYL COVE BASE INCLUDES STOREFRONT, DEDUCT IF NOT NEEDED VERIFY WITH PROPERTY MANAGER IF EXISTING FLOOR COVERAGE TO REMAIN FLOORINGMALL FINISH SCHEDULE MEMO No MENOMINEE MENNEEN MEN MEN OEM ON mommosom Emommom moommommom 0 5 FINISH SCHEDULE 'I SCALE. 1 1 1 1 1 1 w � 1 ac 1 1 1 1 PROVIDE AND INSTALL A 2-A RATED FIRE EXT. (MIN.) IN A COASpMCUOUS LOCATION N ACCORDANCE YMTFH STATE AND LOCAL CODES, r 1 i T 3n7r 30172• s 1 C-1 M 3C'xTI 3'tcAr 1' j ...go— f � f I c 1 ' i 3�1rT1" 30'x? v I � 24'��a48' o -- a 1816 I� r . +r. VCT -1 I � AlL AIL [71 Ln ri i? MANAGER 107 > LOUNGE _ 108 r- SALES � II - I1 L L J L J_ L w w PIE -`%` `n r � � 0 6 cn W .j 0 0 W cr) Z U w W Z U Q r J W Q- z _ LL c T_ ..Ji:)co z Q J LL W U) LL Y g W Z W U-) Y X W m � F_ lL O .o o • gyp '�► , o W � tol: Q� -°i�o Q u, ; 0 t_a o046 0 a Z_cm ag V Q ge �. ' i;•'�'�;i� liii O O �I 0 I A2GIi: + ALT s- i V ^ y'f '7• yy 7 � • j - �7T�:� •i L Its. J Y .Pw, a Y VC S*R.CTums aye 1V` >Ra■w �! Cods IN SJc � Sale 011lae 05�2208 �►s Iwa� IIIi,�-� J� Aa smw f. A�3 i s FLAME SPD./ CODE /USE MOKE INDE DESCRIPTION ALTERNATE: PROVIDED BY: INSTALLED BY: COMMENTS AMERICAN OLEAN- HOME DEPOT - DAL TILE - DEMETRA PORCELAIN USE SABLE BROWN - CT1 N/A SELECT PORCELAIN TILE TILE P052, A188- 398'PARADISO SAND 13'x13' GENERAL. GENERAL POLYBLEND #95 GROUT CERAMIC TILE - #SL51 "ALMOND' 12'x12` HOME DEPOT - DAL TILE - TRAVERSA GLAZED CONTRACTOR CONTRACTOR ALTERNATE HYDROMENT #627 -327 OR 16'x1' _ TILE A155-009 "GOLD" 12"x12'. I FLASH WALNUT GROUT VCT1 ARMSTRONG-STANDARD ARMSTRONG- STANDARD VINYL COMPOSITION FLAMMABILITY 1 EXCELON, #51803 PEARL. EXCELON, #51810 WASHED TILE WHITE LINEN ARMSTRONG STANDARD SHEET ---� VC1 NIA VINYL/LINOLEUM G.0 TO SHEET VINYL CORRDINATE WITH HSBC PROPERTY MANAGER ON BRAND. JOHNSONITE #80 FAWN 1i8" I 4 " HIGH BI VINYL BASE FLAMMASILITY:1 ROPPE #140 FAWN 1B' VINYL COVE BASE, 4' H VINYL COVE BASE 4" N JOHNSONITE #CTA -XX -A TS1 ROPPE #177 CARPET TO TRANSITION STRIP NIA TILE ADAPTOR COLOR: #140 FAWN CARPET TO TILE ADAPTOR COLOR: #80 FAWN LEES - FACILITIES #224 SEE NOTE #1 C1 (ASTM E 648 )CLASS 1 INTERFACE CARPET HOUSEHOLD FLOOR SEALER: CARPET (ASTM E .662) 450 SYMMETRY #4295 ETCHING BROWN INTERNATIONAL,. I LEES- EVERSEAL (ASTM E•84) DSI - KOROSEAL DSI - KOROSEAL �— WC1 (TUNNEL TEST) ARCADIA #A421-04 VIEWPOINT #V221 -33 SEE NOTES #2 AND #3 VINYL WALLCOVERING FLAME SPREAD: 10 SYCAMORE 54" w/ NO DRIFTWOOD 54" w/ NO SMOKE INDEX: 5 REPEAT REPEAT ARMSTRONG FISSURED GENERAL. CEILING GRID - ARMSTRONG (OR ACT1 (ASTM E 1264) MIN BOARD 2'X4' WHITE CONTRACTOR EQUAL) 15116 WHITE FOR 2514' ACOUSTICAL CEILING ACOUSTICAL CELL. TILES 3"R-1 1 TILE CLASS A PAPERFACED BATT INSULATION (7X4' LAY -IN) ABOVE CEILING TILES BENJAMIN MOORE SHERWIN WILLIAMS SW r READY MIX - ATRIUM 1910 TENNIS WHITE WALLS IN BREAK/STGfTOILET P1 NIA WHITE REGAL AQUA PRO MAR 200 LATEX ROOMS SEE NOTES #2 AND #4 PAINT VELVET LATEX EGGSHELL ENAMEL EGGSHELL ENAMEL BENJAMIN MOORE SHERWIN WN-LIAMS #1018 #1086 SAND STORM DOORS AND FRAMES P2 NIA REGAL AQUA GLO, LATEX PRO MAR 200 THROUGHOUT SEE PAINT SEMI -GLOSS ENAMEL SEMI -GLOSS ENAMEL NOTES #2 AND #4 HB1 NIA VISTA -1" METAL #006 'RAW UMBER" OR #205 HOUSEHOLD PROVIDE Q STOREFRONT MINI BLINDS WHITE SATIN INTERNATIONAL VENDOR SEE NOTE 5 (ASTM E-84) N EVAMAR #S-7-24T PL1 (TUNNEL TEST) WILSONART #D 354-6 DESIGNER CHALK WHITE MATTE GENERAL GENERAL COUNTER TOP FOR BREAK PLASTIC LAMINATE FLAME SPREAD: 55 WHITF MATTE FINISH FINISH CONTRACTOR CONTRACTOR ROOM CABINETS SMOKE INDEX: 40 FRP (ASTM E-84) MARLITE #5-100 FORMICA #934 4'-0" TALL AROUND FIBER REINFORCED CLASS III/ C WHITE SLATE PEARL- BATHROOM WALLS POLYESTER PANELS SEE ROOM FINISH 5 FINISH SCHEDULE 'I SCALE. 1 1 1 1 1 1 w � 1 ac 1 1 1 1 PROVIDE AND INSTALL A 2-A RATED FIRE EXT. (MIN.) IN A COASpMCUOUS LOCATION N ACCORDANCE YMTFH STATE AND LOCAL CODES, r 1 i T 3n7r 30172• s 1 C-1 M 3C'xTI 3'tcAr 1' j ...go— f � f I c 1 ' i 3�1rT1" 30'x? v I � 24'��a48' o -- a 1816 I� r . +r. VCT -1 I � AlL AIL [71 Ln ri i? MANAGER 107 > LOUNGE _ 108 r- SALES � II - I1 L L J L J_ L w w PIE -`%` `n r � � 0 6 cn W .j 0 0 W cr) Z U w W Z U Q r J W Q- z _ LL c T_ ..Ji:)co z Q J LL W U) LL Y g W Z W U-) Y X W m � F_ lL O .o o • gyp '�► , o W � tol: Q� -°i�o Q u, ; 0 t_a o046 0 a Z_cm ag V Q ge �. ' i;•'�'�;i� liii O O �I 0 I A2GIi: + ALT s- i V ^ y'f '7• yy 7 � • j - �7T�:� •i L Its. J Y .Pw, a Y VC S*R.CTums aye 1V` >Ra■w �! Cods IN SJc � Sale 011lae 05�2208 �►s Iwa� IIIi,�-� J� Aa smw f. A�3 i s 1 VERIF Y EXISTING CONDITIONS AND LOCATIONS INFIELD PRIOR TO SUBMIT T ING PROPOSAL FAILURE TO 00 SO SHALL NOT REL IEVE THIS CONTRACTOR FROM PERFORMING THE WORK REQUIRED UNDER THIS CONTRACT 2 MAKE NECESSARY MODIFICATIONS AND ADJUSTMENTS TO ALL ELECTRICAL ITEMS AND EQUIPMENT. BOTH NEW AND EXISTING, AS MAY BE REQUIRED BY THESE AL I k 4A I IONS AND ADDITIONS 3 THIS CONTRACTOR SHALL FURNISH AND INSTALL ALL MATERIAL INDICATED ON DRAWINGS AND AS RkQUIkkU 1 0 PROVIDE A COMPLETE AND SAT ISFACTORY OPERAI ING INSTALLATION INSTALLATION SHALL BE LEFT IN OPERATION 4 ALL MATERIALS SHALL_ BE NEW AND OF STANDARD QUALITY, NO REJECTS ALL MATERIALS FOR WHICH AN UNDERWRITERS LABORATORIES STANDARD EXISTS SHALL BEAR A U L LABEL. PROTEC I ALL E(AJIPMENT AND WORK FROM DRAINAGE DUE TO My CAUSE. 5 DUPLEX RECEPTACLES SHALL BE HUBBELL #5242 OR APPROVED, OR EQUAL. SINGLE POLE SWITCHES SHALL BE HUBBELL #1201 OR APPROVED EQUAL COVER P LATES SHALL BE PLASTIC, IVORY OR BROWN AS SELECTED BY PROPERTY MANAGER. HUBBELL #98000 OR 999000 SERIES OR APPROVED EQUAL. AND SHALL BE INSTALLED 1S" A.F.F. 6. IN GENERAL, FLUORESCENT LIGHTING CIRCUITS SHALL BE 20 AMP #12 TW WIRE MINIMUM, INCANDESCENT LIGHTING CIRCUITS SHALL BE 20 AMP. #12 TW WIRE K41KIMUM AND RECEPTACLE CIRCUITS SHALL BE 20 AMP, #12 TW WIRE MINIMUM 7 ALL WIRE SIZES INDICATED ARE FOR COPPER CONDUCTORS ALL WIRE SHALL BE COPPER. ALL WIRING SHALL BE INSTALLED IN E M.T. CONDUIT FLEXIBLE METAL CONDUIT MAYBE USED FOR CONNECTIONS TO FIXTURES LOCATED IN ACCESSIBLE TILE CEILINGS. 8- T H!S CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PLAN EXAMINATION FEES, PERMITS, AND JOB INSPECTION FEES REQUIRED FOR THIS WORK. 1 9 ALL WORK SHALL BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE LAWS, ORDINANCES, REGULATIONS, AND ELECTRICAL CODES 10. THIS CONTRACTOR SHALL COORDINATE HIS WORK WITH ALL ARCHITECTURAL, STRUCTURAL, AND MECHANICAL FEATURES OF THE BUILDING, CONSULT ARCHITECTURAL, STRUCTURAL AND MECHANICAL PLANS. ADJUST WORK TO FIT ACTUAL JOB CONDITIONS. COOPERATE WITH OTHER CONTRACTORS. 11. THIS CONTRACTOR SHALL REMOVE ALL RUBBISH, DEBRIS, ETC. CAUSED BY HIG WORK AS FAST AS IT ACCUMULATES. 12. THIS CONTRACTOR SHALL GUARANTEE ALL OF HIS WORT( FOR ONE YEAR AFTER DATE OF WRITTEN ACCEPTANCE BY OWNER AGAkST ALL DEFECTS OF MATERIAL, EQUIPMENT AND WOR MANSHIP. ALL SUCH DEFECTS APPEARING WITHIN THE GUARANTEE PERIOD SHALL BE PROMPTLY REMEDIED WITHOUT FURTHER COST TO THE OWNER. ENTIRE INSTALLATION SHALL BE GUARANTEED TO OPERATE SATISFACTORILY. 13. EXTRA WORK MUST BE APPROVED IN WRITING BY THE PROPERTY MANAGER. WITHOUT THE WRITTEN APPROVAL, NO EXTRA PAYMENT WILL BE MADE. 14. THIS CONTRACTOR SHALL DO ALL CUTTING AND PATCHING REQUIRED FOR HIS WORT( 15. ALL DUPLEX AND QUAD RECEPTACLES SHALL BE LOCATED AT 15 ABOVE FINISHED FLOOR, UNLESS NOTED OTHERWISE. l�R/FY L OCA 7/OA( OF J BOX FOR S/GNAGE I - A -25= � I 111 A -23- / ; -2. -AAA" A -2, 4 t 1 i i \ y �. . ' • -ti ' A -5 E I A-12 + rA - 5> > - -5,7,9 t_ _A -24 /. i PANEL A - f 3 ' I ! A- 14,16.18 T i A-- 14, . , f I t 1 I A - �, • - _ _- I I � `- fi t--. • ' I = 1 I- ri t OF I T ELECTRICAL PLAN 16 AT DATA CABINET, ALL DUPLEX AND QUAD RECEPTACLES SHALT. BE LOCATED AT 44 ABOVE FINISHED FLOOR EACH ON THEIR OWN DEDICATED CIRCUIT. 17 EXISTING LIGHT FIXT URES, RECEPTACLES, SWITCHES AND ELECTRICAL PANELS SHALL BE REIAINEU AND REUSED AS POSSIBLE. 18 SIGN CIRCUIT - (NORMALLY REQUIRED) - THE ELECTRICAL SERVICE CONSISTING OF ONE 20 AMP CIRCUIT IS TO BE PROVIDED FOR THE EXTERIOR SIGN IT WILL BE SWITCHED BY A TIME CLOCK LOCATED ON THE WALL NEXT TO THE ELECTRICAL PANEL- THE TIME CLOCK IS TO BE TOF:K MODEL 4110124 HOUR CLOCK OR COMPARABLE SUPOLIED BY THE CONTRACTOR. THE CIRCUIT WILL TERMINATE IN A JUNCTION BOX NOT FURTHER THAN 3' FROM WHERE THE SIGN IS TO BE INSTALLED. THE SIGN WILL BE FURNISHED BY BENEFICIAL TO DETERMINE WHERE THE SIGN IS TO 3E LOCATED 19. TELEPHONE AND DATA - PROVIDE A JUNCTION BOX LOCATED 15' ABOVE FINISHED FLOOR TO JUST ABOVE THE CEILING AT EACH LOCATION WHERE DATA AND/OR PHONE IS TO BE INSTALLED. NO JUNCTION BOX IS NEEDED WHERE THE WIRING WILL TERMINATE IN THE DATA ROOM. USE 14' CONDUIT ONLY 20. CONDUIT SHOULD BE 3 4 - WITH JUNCTION INSTALLED AT A MINIMUM OF 15' A.F.F. AND A PULL STRING. DATA DROPS WILL BE CAT 5 WIRE WITH TWO DATA AND TWO VOICE AT EACH STATION. 21 ALL WORK SHALL COMPLY WITH THE CURRENT EDITION OF THE NATIONAL ELECTRICAL CODE AND ALL LOCAL CODES -"OORDINATE EXACT CODE REQUIREMENTS AND LOCAL AMENDMENTS WITH LOCAL INSPECTOR PRIOR TO ANY INSTALLATION. 22 ALL BRANCH CIRCUIT BREAKERS SHALL BE "PLUG-ON' TYPE RATED AT 20 AMPERE -1 POLE FOk 75 C WIRE, UNLESS NOTED. 23. ALL 20 AMP CIRCUIT BREAKERS USED AS SWITCHES SHALL BE ULSWD RATED & SHALL BE MARKED "SWD'. 24. PROVIDE SPACES WITH MOUNTING HARDWARE FOR FUTURE BREAKER INSTALLATION 25. PANELS TO BE MANUFACTURED BY SQUARE')' (OR APPROVED EQUIVALENT), WITH FLUSH LOCK AND KEYED ALIKE. 26. NO MORE THAN 3 WORKSTATIONS ON A CIRCUIT. 27. NIGHT LIGHT(s) TO BE "ON" 24 HOURS CONTINUOUSLY. 28. EXISTING RTU's AND DUCTWORK TO REMAIN, REROUTE NEW DIFFUSERS WITH FLEX INTO EXISTING DUCTWORK 1 I ELECTRICAL NOTES SCALIE 1 200, v.11 1, ` l r ... .L Y .. 2� /l� t .� '. ��• r ` l��T - I • , v ' •rJ Y ; .. r , � 1. �\�'. .. -, Jr � .. I 1' ._.,.1 �. (. - _ � � I' � y _/•� .- —_— t `1• '� JE • y CF• T r, j I I r I NOTES I _ ! 1 FURNISH AND INSTALL LIGHTING CONTROL CONTACTORS, IN A HINGED NEMA t ENCLOSURE OF ^f � �t�l ; 1 • _I 1 i :' 1 ;, ' 1 ' 1 r 1 , } — - - . �,- • - -� -- - ADEQUATE SIZE, SURFACE MOUNTED NEXT TO ELECTRICAL PANEL CONTACTORS SHALL BE MULTI - POLE, 20 AMP RATED ELECTRICALLY HELD, MANUFAC f URED BY SQUARE -D OR APPROVED EQUAL PROVIDE 3 �, 1 ) / , c ��,• : , .,! . ; R. TERMINAL STRIPS FOR All LINE AND LOAD CONDUCTORS IDENTIFY THE CIRCUIT NUMBER FOR EACH 4 CONDUCTOR USING WIRE LABELS AND PROVIDE A SCHEDULE INSIDE OF THE ENCLOSURE IDENTIFYING 1- , �; , THE LOAD 1 �� � 1 y EACH clRculT SERVES ' 1 T �1 2 ALL LIGHTING CONTACTORS TO HAVE A M!N OF IS.O U A I C INTERRUPTING RATING 54 fit• . `� �, �. , ';1 , ! 0 , H „ ', j �F . ' ` A ' L, . ;,; . • I • • ; •; N 120 - - - - -- l�: rt, -- -I r.. �, I I OU'�,•� 5 TVOR — -f - -- __ ---- 1 -- _ - -- --: - - __- {� 1 - _ I - S ITS - ---� 00 v( ,'�< } 1�1.•GI LyE �' A1� : , ^ !( J; Breakers I - - - - -- -- - _. - — -- _- - - - - - -- @ Panel I - � F - - - - -� ;; � ' 1 1 _- TS1 P1 -- -- - --� � t -- S -- -� -- NEMA II Sr :;r :�.I I I I "= '1 ► 5� j `= I Enclosure I I I ` c' 1 J SP n - -- I With Hinged Lockable I I 1-1 - - -. - - - -- - --- - ---�- - - ---: - -: ____ I Door - Recessed Mount Size asRewimd - --- --�-�• 1 41 j VERIFY EXISTING RTU. ADJUST BREAKER SIZE AND WIRE SIZE ACCORDING - SIGN' 3 ELECTRICAL LEGEND TO EXISTING CONDITIONS. 0 _ --� - - - - -- VERIFY EXISTING HWH. ADJUST BREAKER SIZE AND WIRE SIZE ACCORDING - - - — - - - -- - - TO EXISTING CONDITIONS. P r. Cvr.' . _ 'c I 'fir :. 3 , _ _ - _ T' METERING EQUIPMENT ,! #6 GROUND IN 21/2" CONDUIT 9 I EXISTING PANEL 'A' i I ONE LINE DIAGRAM ! K,T�.rc.} �. p! 0 C - -- ---r -- ' _' L0. _ _ C o� 0! C C' L0 -_ -- 2- , 2 PANEL DIAGRAM r r� } I C - 24 "x72" ROLLING 0 CABINET 4 C DATA CABINET &PHONE BOARD Cam' �,�. y N C ' O �� �� —w •- .�,•�. +�.... -.�-�. +��..�.- •.•+r- -s ,ter -. �.. - 'w + +� �+r �.�� � v+.�.�.�.�'. i'e"n'�.wvti��_ - -. _ ..- �... _ice �. �.rr��� �- 4'x4' PLYWOOD FOR PHONE EQUIPMENT MOUNTING cc 4) Q O J W W az Uo 0 w Z� J> CID Uj co Q J00 Q W m Q U °tS LLw� � Z Zm3 W C� Y CCC m � H W J . o V° 40 a = a LU ce 0 v 4; Co. C? =.00 z V...� .. < 1. 0 mm i O • • a. Z00, _() =QC o atv too q No d 1I + •!III; :1.... , ....Il�il, I 0 0 # �g I - ESE a_ a* -++; � �iF : JUF� � :JaG�.�5iC1r. �IIC - f" _ ''f f• : _ vP a''�rC *C S' -Ikjc � me out 31wc f 0 fir+ 91r C?Krllet 96 Saft Dm 05-2208 _r E -1 H-V, 1 HEATING, VENTILATiNG AND AIR CONDITIONING CONTRACTOR SHALL FURNISH AND INSTALL ALL DUCTWORK, DUCTWORK INSTALLATION, REGISTERS, GRILLES DIFFUSERS AND TERMINAL BOXES 2 HEATING, VENTILATING AND AIR CONDITIONING CONTRACTORS SHALL FURNISH ALL EQUIPMENT TEMPERATURE CONTROL COMPONENTS AND ANY SPECIAL MOUNTING OR SUPPORT PACKAGE 3. HEATING, VENTILATING AND AIR CONDITIONING CONTRACTORS SHALL INSTALL ALL H V A C . EQUIPMENT 4 ALL WORK TO COMPLY TO LOCAL, MUNICIPAL AND NATIONAL HEATING AND VENTILATION CODES. 5. CONTRACTOR TO COORDINATE ALL WORK WITH THE RESPECTIVE TRADES AND VERIFY LOCATIONS FROM THE ARCHITECTURAL DRAWINGS AND FIELD MEASUREMENTS AND SUPPLIER SHOP DRAWINGS. 6. CONTRACTOR TO VISIT THE SITE TO DETERMINE THE FUL: EXTENT OF THE WORK AND FACILITY LOCATIONS AND VERIFY WITH GOVERNING BODIES. � GENERAL NOTES SCALE LIGHTING PLAN ALL H I PM E EX TO BE REUSED 7 OBTAIN AND PAY ALL PERMIT AND INSPECTION FEES AS REQUIRED FOR THIS PORTION OF THE WORK, 8. LAYOUT IS DIAGRAMMATIC AND CONTRACTOR SHALL INSTALL EQUIPMENT AND DUCTWORK TO MEET THE FIELD CONDITIONS AND PROVIDE SHOP DRAWINGS AS MAY BE REQUIRED FOR THE WORK. 9. ALL DUCTWORK CONSTRUCTION SHALL CONFORM TO LOCAL CODES AS WELL AS A.S.H.R.A.E. AND S.M.A.C.N.A. CONSTRUCTION STANDARDS FOR LOW VELOCITY DUCTWORK CONSTRUCTION AND N FPA 190-A. 10. BRANCH TAKE -OFFS SHALL HAVE SPUTTER DAMPERS OR MANUAL DAMPERS FOR ALL SUPPLY OR RETURN AIR DUCT BRANCHES. ALL MAIN BRANCHES SHALL HAVE MANUAL DAMPERS. 11. UPON COMPLETION OF INSTALLATION OF VEN fILATION DUCTS, CLEAN ENTIRE SYSTEM OF RUBBISH, PLASTER, DIRT, ETC BEFORE INSTALLING GRILLES OR DIFFUSERS. SYMBOL DESCRIPTION c 4) Im ccc EXISTING 70 +-' -- ��-. � .r.w+ �..�..e.• �..�irs -.. - .rte a. _ � � ._ _ ,...�� - -.�,. - ...�-- ��.n.- - — �. . �. ._- ..r .- -- rte . . �.�..- !1 �-- -- .�- '+ - w.� --w�. �w PRISMATIC 4 BULB ,a W ~ FLUORESCENT FIXTURE Z I EXISTING 70 PRISMATIC 3 BULB _ - w Q > 7 ._-.1Q FLUORESCENT FIXTURE f %� I 7x4' PRISMATIC 4 BULB FLUORESCENT FIXTURE (1) TUBE OPERATING AS A NIGHT LIGHT. TYPICAL SUPPLY DIFFUSER WITH MANUEL DAMPER TYPICAL RETURN/ EXHAUST GRILLE I , SYMBOL i t I� (T I DESCRIPTION SINGLE POLE SWITCH ( +4'-W A.F F.) HONEYWELL'MAGICSTAP PROGRAMMABLE THERMOSTAT OCT3200A1001 OR EQUAL. COMBINATION EXIT SIGN & EMERGENCY LIGHT COMBINATION LIGHT! EXHAUST FAN (TOILET ROOM) I I ?C 2-A RATED FIRE EXTINGUISHER r i 2 FIXTURE LEGEND F l i " E I I C.: t r c - I I F i 1 , J G.C. TO VERIFY ALL EX,STING CE €LING CONDITIONS AND ADjlJST AS NFLDED �� cc c 4) Im ccc w +-' -- ��-. � .r.w+ �..�..e.• �..�irs -.. - .rte a. _ � � ._ _ ,...�� - -.�,. - ...�-- ��.n.- - — �. . �. ._- ..r .- -- rte . . �.�..- 0 �-- -- .�- '+ - w.� --w�. �w Z IT-- ,a W ~ Z c o L -..w- - -� '�' --�� �-+w� w Q > J ._-.1Q rn �'`�'�...- s... "'w—� w Y � w �-- Zm� _ WAY J . o o C� • ' W rq p V N CID Z I U ~ " " id Q V 3 ° o �- U - — o o '0 VaCps� F Z I ICU � 0 0 0 0 ,� SOY s�►�Sr Now ^ � dw ' s Ea . t - -•E i_4M - evF jL E: SPKaw9C% aE - f - E f �.a l » 4 00 31?4AC* S : - -Wft AW art 4- ?'- S�J4 njws am I LI P..wi4 0 aqw, 0410a i% IIIIIII� GRS 4 s A 05�22%10 SAM Ift �E�2 12. AFTER ADJUSTMENTS HAVE BEEN MADE TO THE HEATING, VENTILATING AND AIR CONDITIONING SYSTEM, THE HEATING, VENTILATING AND AIR CONDITIONING CONTRACTOR SHALL BALANCE THE AIR DISTRIBUTION SYSTEM, SUBMIT THREE SETS OF DATA OF THE TEST AND BALANCE TO THE OWNER FOR APPROVAL. 13. ALL NEW DUCTWORK SHALL BE LINED WITH 1' FIBERGLASS ACOUSTIC LINING, CONSTRUCTED PER SMACNA STANDARDS, STANDARDS, MAXIMUM 5'4r FLEX DUCTWORK ALLOWED. 14. PROVIDE FACTOR FABRICATED TURNING VANES IN ALL SQUARE TURN ELBOWS. 15. PROVIDE FLEXIBLE DUCT CONNECTORS BETWEEN DUCTS, FANS AND AIR HANDLING UNITS AND ALSO IN DUCTS CROSSING BUILDING EXPANSION JOINTS. 16. NO GRILLES WILL BE INSTALLED IN ANY DOOR NOR WILL UNDERCUTTING OF ANY DOOR BE PERMITTED, 17. PROVIDE MANUAL DAMPERS AT SUPPLY GRILLES. 18. PROVIDE MECHANICAL VENTILATION h ALL ROOMS CAPABLE OF SUPPLYING A MINIMUM OF 15 CUBIC FEET PER MINUTE OF OUTSIDE AIR. 19, G.C. TO COORDINATE WITH SPRINKLER CONTRACTOR ON ANY ADJUSTMENTS TO EXISTING SPRINKLER SYSTEM. (IF APPLICABLE) 7 : 1 +-' -- ��-. � .r.w+ �..�..e.• �..�irs -.. - .rte a. _ � � ._ _ ,...�� - -.�,. - ...�-- ��.n.- - — �. . �. ._- ..r .- -- rte . . �.�..- �- rr. �'w�,�,�- �..- w�.+... �� ��� �.-- .r.�.�.�.. �-- -- .�- '+ - w.� --w�. �w -..w- - -� '�' --�� �-+w� - .....r .� —..� - � - .� �..� -� __ �... -- _�._ r•- -..�► .� ��._. -_r- � "1 .ter. +� -. w- +..�. - as+��.� �r .. '1wi�/w����- �f��..� _� �'_ +�- � - L �'`�'�...- s... "'w—� 12. AFTER ADJUSTMENTS HAVE BEEN MADE TO THE HEATING, VENTILATING AND AIR CONDITIONING SYSTEM, THE HEATING, VENTILATING AND AIR CONDITIONING CONTRACTOR SHALL BALANCE THE AIR DISTRIBUTION SYSTEM, SUBMIT THREE SETS OF DATA OF THE TEST AND BALANCE TO THE OWNER FOR APPROVAL. 13. ALL NEW DUCTWORK SHALL BE LINED WITH 1' FIBERGLASS ACOUSTIC LINING, CONSTRUCTED PER SMACNA STANDARDS, STANDARDS, MAXIMUM 5'4r FLEX DUCTWORK ALLOWED. 14. PROVIDE FACTOR FABRICATED TURNING VANES IN ALL SQUARE TURN ELBOWS. 15. PROVIDE FLEXIBLE DUCT CONNECTORS BETWEEN DUCTS, FANS AND AIR HANDLING UNITS AND ALSO IN DUCTS CROSSING BUILDING EXPANSION JOINTS. 16. NO GRILLES WILL BE INSTALLED IN ANY DOOR NOR WILL UNDERCUTTING OF ANY DOOR BE PERMITTED, 17. PROVIDE MANUAL DAMPERS AT SUPPLY GRILLES. 18. PROVIDE MECHANICAL VENTILATION h ALL ROOMS CAPABLE OF SUPPLYING A MINIMUM OF 15 CUBIC FEET PER MINUTE OF OUTSIDE AIR. 19, G.C. TO COORDINATE WITH SPRINKLER CONTRACTOR ON ANY ADJUSTMENTS TO EXISTING SPRINKLER SYSTEM. (IF APPLICABLE) 7