DEVELOPMENT PERMIT
Steven M. Mullet, Mayor
Steve Lancaster, Director
Parcel No.: 0223100080 Permit Number: DOS-220
Address: 415 BAKER BL TUKW Issue Date: 07/25/2005
Suite No: Permit Expires On: 01/21/2006
Tenant:
Name: BENEFICIAL FINANCE
Address: 415 BAKER BL, SUTIE 104, TUKWILA WA
Owner:
Name: BAKER SQUARE RETAIL BLDG PT Phone:
Address: C/O SOLLY BRUCE DEVELOPMENT, 415 BAKER BLVD STE 200
Contact Person:
Name: DOUG POESCHEL Phone: 206 - 276 -3754
Address PO BOX 6315, FEDERAL WAY WA
Contractor:
Name: RIVER CITY CONSTRUCTION INC Phone: 253- 939 -4545
Address: PO BOX 6315, FEDERAL WAY, WA
Contractor License No: RIVERCC1170B Expiration Date: 06 /06/2007
DESCRIPTION OF WORK:
TENANT IMPROVMENT - SPACE EXPANSION, REMOVE AND ADD NEW WALLS.
Value of Construction:
$54,000.00
Fees Collected:
$1,378.46
Type of Fire Protection:
SPRINKLERS
International Building Code Edition:
2003
Type of Construction:
VB
Occupancy per IBC:
0008
Public Works Activities:
Channelization / Striping:
N
Curb Cut / Access / Sidewalk / CSS:
N
Fire Loop Hydrant:
N
Flood Control Zone:
N
Hauling:
N
Land Altering:
N
Landscape Irrigation:
N
Moving Oversize Load:
N
Sanitary Side Sewer:
N
Sewer Main Extension:
N
Storm Drainage:
N
Street Use:
N
Water Main Extension:
N
Water Meter:
N
Number: 0
Start Time:
Volumes: Cut 0 c.y.
Start Time:
f
Size (Inches): 0
End Time:
Fill 0 c.y.
End Time:
Private: Public:
Profit: N Non - Profit: N
Private: Public:
doc. IBC - Permit 005 -220 Printed: 07 -25 -2005
City a. lTukwila
Department of Commutdty Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: cOukwila.wa.us
Z
W:
D
UO
Cl) o .
LU
J CO) LL
w O
U _
U) c
i d.
�w
Z �.
z O
UJ
� o
O CO
w
F U`
U. O
Z
U
H-
0 :
Z
I
�J�� "kgiP
N 2
.r
iso8
y
City o : Tukwila Steven M. Mullet, Mayor
Departnietit of Community Development Steve Lancaster Director
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: cOukwila.wa.us
Permit Number D05 -220
Issue Date: 07/25/2005
Permit Expires On: 01/21/2006
Permit Center Authorized Signature: Date: 7/S
�
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and
ordinances governing this work will be complied with, whether specified herein or not.
The ng�of this permit does not 1 esume to give authority to violate or cancel the provisions of any other state or local laws
regu sting construction or the performance of wor I am uthorized to sign and obtain this development permit.
Signature: d Date:
1' Print Name:
E
1 This permit shall become null void if the work is not commenced within 180 days from the date of issuance, or if the work is
suspended or abandoned for a period of 180 days from the last inspection.
doc: IBC- Permit D05 -220 Printed: 07 -25 -2005
1
Z
Z '.
W
2
Q � ...
J V
U0 ,
co o.
w=
J H
CO u,,.
W 0;
LL Q
S2 d'
H=
Z
z0
W LLJ
� o
U
0 -
off
w
L 0
iu Z
U N
H X
O
Z
City of Tukwila
Department of Community Development 16300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
PERMIT CONDITIONS
Parcel No.: 0223100080 Permit Number: DOS-220
Address: 415 BAKER BL TUKW Status: ISSUED
Suite No: Applied Date: 06/28/2005
Tenant: BENEFICIAL FINANCE Issue Date: 07/25/2005
1: ** *BUILDING DEPARTMENT CONDITIONS * **
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431- 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design
requirements of ASCE 7.
6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced
to the building structure.
7: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
8: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building
inspector. No exception.
9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Department of
Public Health - Seattle and King County (206/296- 4932).
10: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department
of Labor and Industries (206/248- 6630).
11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
12: ** *FIRE DEPARTMENT CONDMONS * **
13: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the
following concerns:
14: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at
one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry
chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1)
doc: Conditions D05 -220 Printed: 07 -25 -2005
i r.. ^'r,} , fr.'o n {.wtt.,..t�i .v �r+y;• d4. ,. �.. ��.•a�Y+..s; `•('" a"•.. c• ; _.
1.. ,1. . L:, u 4.,,.:1, _ /,.:.' ,;:' �k?- vsH":.<: i3'` �: r° , :- , a'Trri'r;vie4�vi'tivjui,� ; � : +:c?. ti':t: #?<ildr, t� +ef• . wt7 .M 3'hytl + ki.:� %iiq w. ,J. :i�.cE �..tx -'�:i t�
z
�z
'~ w
�0
UO
No
Cl)
Nw
W 0
U.
= C1
�w
Z
H
1--0
Z
W
w
U�
O N
� 1—
wW
U_
w
Z
U=
O
Z
ti
City of Tukwila
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
15: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or
Q
brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation
_
instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so
W
that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross
2
weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the
o
floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4
U o
Cl)
inches (102 mm). (IFC 906.7 and IFC 906.9)
w =
16: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot
CO u_
be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6)
g 0
17: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available
a
for use. These locations shall be along normal paths of travel, unless the fire code official determines that the
to d
hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5)
w
Z
18: ** *MEANS OF EGRESS * ** - IFC Chapter 10
F .. p
19: No point in a building may exceed the maximum exit access travel distance listed in Chapter 10, section 1015, Table
Z�_
w w
1015.1 of the International Fire Code and International Building Code.
v o
--
20: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort.
O
0 H
(IFC 1008.1.8.3 subsection 2.2)
H v
21: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle
�
O Z
iw
is engaged from inside the tenant space. (IFC Chapter 10)
co
22: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10)
z ~
23: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress
travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress
travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access
corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the
nearest visible exit sign. (IFC 1011.1)
24: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90
minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system
provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3)
25: Means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means
of egress is occupied. The means of egress illumination level shall not be less than 1 foot - candle (11 lux) at the
floor level. The power supply for the means of egress illumination shall normally be provided by the premise's
electrical supply. In event of a power failure an emergency power system shall provide power for a duration of not less
than 90 minutes and shall consist of storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2,
1006.3)
26: ** *FIRE ALARM SYSTEMS * ** - City Ordinance #1900 - NFPA 72
27: Maintain automatic fire detector coverage per N.F.P.A. 72. Addition/ relocation of walls, closets or partitions may
require relocating and /or adding automatic fire detectors.
28: Maintain fire alarm system audible /visual notification. Addition /relocation of walls or partitions may require
relocation and /or addition of audible /visual notification devices. (City Ordinance #2051)
doc: Conditions
D05 -220
nted: 07 -25 -2005
J... r: ..a a,.,� is �.�r...Ze".!.`,t ::i 4..: ir�'un;��'K,t::3i. v..t rrl s�l'x� "•� ,• �F ..:ii �X �� , t 7.oi . ' 2iSknnYri w :.:i',' :�4n� .0 r� :.'s � .: i.: H: v,: n::. wir. o- ..4,::s. +.acs,�t.L.:u.:.;.'µ -.Lx.rt•'
City of Tukwila
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
29: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire
Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC
30: Call the Tukwila Fire Department at 206/575 -4407 for approval of any system shut down. Have job site address, name and
3
the Tukwila Fire Department Job Number available to confirm shut down approval. (City Ordinance #2051)
! 31: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and
#2051)
32: ** *BUILDING CONSTRUCTION * ** - IFC - IBC
i
33: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth
in Table No. 803.5 of the International Building Code.
34: Accumulation of combustible waste material is prohibited during the demolition phase of this project. Remove and
properly dispose of all waste material prior to the close of the working day and as often throughout the day as needed.
35: These plans were reviewed by Inspector 510. If you have any questions, please call Tukwila Fire Prevention Bureau at
(206)575 -4407.
* *continued on next page **
z
Z
W W
U O'
U) 0
J �
L
W
2�
LLa
CC%:
=w
z F-
ZO
w
w
U 0'
' O S
off
2V
H�
O'
U — .
p _
O ~'
Z
! doc: Conditions D05 -220 Printed: 07 -25 -2005
r
Cit y of Tukwila
1908
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 (206) 431 -3670
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws
regulating - construction or the performance of work.
Signature . .-- fir~ ,�i 6 Date
Print Name:
doe: Conditions D05 -220 Printed: 07 -25 -2005
(W o"3 - *IL A, w CITY OF T UKWI LAS � Community Developmebt department
Public Works Department
Permit Center
1908 6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
i
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
SIMEOCATION
King Co Assessor's Tax No.: eo?,
Site Address: V 'J a k w l tJ Suite Number: Floor
Tenant Name: CJ ` t�Qw New Tenant: ❑ .. Yes 2'.No
Property Owners Name: 4 r- tA d C
Mailing Address: �Q
City State Zip
.`CONTACTPERSON .
Name: (I Day Tel phone: S
Mailing Address: < �
E -Mail Address: �03,2 S [' lL e f T� 1.M( CtA Ste of Fax Number: a 3 9 3 9 — 4 /3 �f
GENERAL CONTRACTOR INFORMATION - (Mechanical Contractor information on back page)
Company Name:
Mailing Address:
City / State Zip /
Contact Person: P 6 Day Telephone: C.CJ (O
E -Mail Address: V. Fax Number: -� -7
Contractor Registration Number: Expiration Date: f� — 7
* *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance **
:ARCHITECT OF RECORD. - All plans must be wet stamped by Architect of Record
Company Name: OW��D
Mailing Address: ✓` --�
city state Z � � u
Contact Perso Day Telephone: I 7 —, Q
E -Mail Address: Fax Number: 6 ��
ENGINEER OF RECORD All plans must be wet stamped by Engineer of Record
Company Name:
Mailing Address
City State Zip
i
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
gAkpc mhs pluslicc changesXpemit application (7 -2004)
Revised: 6.8.05 Page t
bh
Z
W
UO
N
CO W
J =
F—
CO W
WO
2 QQ
tL
CO)
=
�W
Z
�O
Z �_
WW
U�
ON
OH
W
H
160
.Z
W
U=
0 �..
Z
BVILDING PERMIT, INFORNYAfION' 206- 431 -3670
:........
Valuation of Project (contractor's bid price): $ lb 7 . U l�J ,�� Existing Building Valuation: $
Scope of Work (please provide detailed info ation): CA
'i
1
I
Will there be new rack storage? ❑ 2 ,/ ..Yes •• No If "yes ", see Handout No. for requirements.
Provide All Building Areas in Square Footage. Below
PLANNING DIVISION:
Single- family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑ ....Yes ❑ ..No If "yes ", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
❑.. Sprinklers Automatic Fire Alarm []..None ❑ . Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ ..Yes 2r
If ' yes ", attach list of materials and storage locations on a separate 8 -112 x II paper indicating quantities and Material Safety Data Sheets,
q:Vpermits plus \ice changes%permit application (7.2004)
Revised 6•8-05 Page 2
bh
�t
ZZ
— Z
�W
Q � Q �
JU
0
(I)0
CO) 11i
J �
U.
WO
J
W Q.
=
FW
Z
H
Z�
�5
U
O CO)
0 H-
W
~ H
L O.
LLI Z
CO)
P H:
O
Z
Existing
Interior .
Remodel
Addition to
Existing
Structure
New
Type of
'Construction .
per IBC
Type of
Occupancy per
IBC
I" Floor
gig
2 ". Floor
r
P Floor
Floors thru
Basement .
Accessory Structure* :.
Attached Garage
Detached Garage
Attached Carport
Detached Carport
Covered Deck
Uncovered Deck
PLANNING DIVISION:
Single- family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑ ....Yes ❑ ..No If "yes ", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
❑.. Sprinklers Automatic Fire Alarm []..None ❑ . Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ ..Yes 2r
If ' yes ", attach list of materials and storage locations on a separate 8 -112 x II paper indicating quantities and Material Safety Data Sheets,
q:Vpermits plus \ice changes%permit application (7.2004)
Revised 6•8-05 Page 2
bh
�t
ZZ
— Z
�W
Q � Q �
JU
0
(I)0
CO) 11i
J �
U.
WO
J
W Q.
=
FW
Z
H
Z�
�5
U
O CO)
0 H-
W
~ H
L O.
LLI Z
CO)
P H:
O
Z
MECHANICAL PERMIT INFL..MATION - 206- 431 -3670
MECHANICAL CONTRACTOR INFORMATION
Company Name:
Mailing Address:
City State Zip
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
Contractor Registration Number: Expiration Date:
* *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance"
Valuation of Project (contractor's bid price): $
Scope of Work (please provide detailed information):
f
i
Use: Residential: New .... ❑ Replacement..... ❑
Commercial: New .... ❑ Replacement..... ❑
i
i
Fuel Type Electric ..... ❑ Gas .... ❑ Other:
Indicate type of mechanical work being installed and the quantity below:
Unit T e:
Qty
Unit Type:
Qty
Unit Type:
Qty
Boiler/Compressor:
Q
Furnace <100K BTU
Air Handling Unit >10,000
Fire Damper
0 -3 HP/ 100,000 BTU
CFM
Furnace>100K BTU
Evaporator Cooler
Diffuser
3 -15 HP /500,000 BTU
Floor Furnace
Ventilation Fan Connected
Thermostat
15 -30 HP /1,000,000 BTU
to Single Duct
Suspended/Wall /Floor
Ventilation System
Wood /Gas Stove
30 -50 HP /1,750,000 BTU
Mounted Heater
Appliance Vent
Hood and Duct
Water Heater
50+ HP /1,750,000 BTU
Repair or Addition to
Incinerator - Domestic
Emergency
Heat/Refrig/Cooling
Generator
System
Air Handling Unit
Incinerator — Comm/Ind
Other Mechanical
<10,000 CFM
Equipment
PERMIT APPLICATION` NOTES - Applicable.to ` 11,permits in this.application
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested
in writing and justifiable cause demonstrated. Section 105.3.2 International Bui ding Code (current edition). .
I HE BY CERTIFY THAT I HAVE READ AND EXAMINED THIS IPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY 13F PERJURY BY THE LAWS - QF THE STATE OF W AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUIL ING O ER OR
Signatu Lr
Print Name:
Mailing Address:
Day
City
,Date:
7 V ^3 /,
State Zip
Date Application Accepted: Date Application Expires: Staff l d 'als:
�-
q:\\purnits plus\ice changes \permit application (7.2004)
Revised: 6.8 -05
bh
Page 4
Z
}�- Z
�W
W Q2
JU
u
to 0
CO LLJ
J �
to LL
WO
9 J
LL Q
C
=
�W
Z
H
H O
Z LU
�5
U�
O�
0 1—
W
3: L )
—0
.• Z
W
F _
O
Z
I
f Tukwila
face Y
l
j 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
RECEIPT
Parcel No.: 0223100080 Permit Number:
Address: 415 BAKER BL TUKW Status:
Suite No: Applied Date:
Applicant: BENEFICIAL FINANCE Issue Date:
DOS -220
APPROVED
06/28/2005
i
:
E
Receipt No.: R05 -01084 Payment Amount:
r
Initials: BLH Payment Date:
User ID: ADMIN Balance:
4 Payee: RIVER CITY CONSTRUCTION
I
i.
TRANSACTION LIST:
i .
Type Ifethod Description Amount
t--- - - - - -- -- - - - - -- --------------------- - - - - -- ------ - - - - --
j Payment Check 16514 837.20
I
I
ACCOUNT ITEM LIST:
.Description Account Code Current Pmts
BUILDING - NONRES 000/322.100 832.70
1. STATE BUILDING SURCHARGE 000/386.904 4.50
I
i
Total: 837.20
837.20
07/25/2005 09:01 AM
$0.00
doc: Receipt Printed: 07 -25 -2005
City of Tukwila
6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 i (206) 431-3670
RECEIPT
Parcel No.: 0223100080 Permit Number: D05-220
Address: 415 BAKER SL TUKW Status: PENDING
Suite No: Applied Date: 06/28/2005
Applicant: BENEFICIAL Issue Date:
Receipt No.: R05-00934 Payment Amount: 541.26
Initials: BLH
Payment Date: 06/28/2005 10:42 AM
User ID: ADMIN Balance: $837.20
Payee: RIVER CITY CONSTRUCTION INC
TRANSACTION LIST:
Type Method Description Amount
---------- -------- --------------------------- ------------
Payment Check 1695 541.26
.z
Z'
QQ
JU
.0 0:
U) LU
wx�
-j F-
0 U-'
' a
w
U-
U)
CY
LU
P
0
z ~- I .
O to
LLJ LLJ
F-
LL
... Z
LU
�0 F-�
z
;.r"'35 X76; --'�7 i ii 'T1')Tt!L VA, I
doe: Receipt Printed: 06-28-2005
t i
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PE MIT NO f
CITY OF TUKWILA BUILDING DIVISION "' ►
6300 S,outhcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Project r
Type of Inspectio
Addr s. 1
Date Called:
Special instructions:
Date Wanted:
r U��.m.
Requester:
Phone No: .r �3/-7
u
u paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspectio
Receipt No.: Date:
f
Y
f
Z
Z
Q� W
W �•
JU
00'
CO) =.
H
W O.
-j
LL Q
N d
~W
Z .
H O
W LL1,
:O co
C) t•-
W W,
IL
H U
U
I-- L
' r .
INSPECTION RECORD
Retain a copy with permi *(2 61431.3 '
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISIO Southcenter Blvd., #100, Tukwila, WA 98188 70
G
M Approved per applicable codes. Corrections required prior to approval.
fkQ ject:
Type of In pection:
d ress: � � .
�
Date Call d: a
a
Spe ial Instructions:
Date Wanted: M.
3 p.m.
o ��
Requester:
P ^
z
�_— Z
Q �W
W�
UO
W ='
Co U
W O
�5
U.
�.
=a
�.. W
�O
.z H
U�
.O N.
WW
U- O
.z
W
v =:
z
{ INSPECTION RECORD
r Retain a copy with permit ��-
INSPECTION NO. PER
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 ( 0 431 -3670
Proj ct:
Type of In ection:
A ess:
Datd Called:
J
Special Instructions:
Date Want d:
Iti
Requester:
Phon
o�
.mss- ao
proved per applicable codes. Corrections required prior to approval. 9
BENTS: I /
Inspector: v Date: -
$58. REINSPECTION EE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcen er Blvd., Suite 100. Call to sechedule reinspection.
Receipt No.: Date:
Z
Z'.
�}" W
_3
UO
W LLI
�L
WO
Ei
U.
U
= CJ
�W
F- O
W H,
W
U
O TO
oF-
W w
F- C.)
� 0
tll Z,
CO)
O
Z
City of Tukwila
Fire Department
TUKWILA FIRE DEPARTMENT
FINAL APPROVAL FORM
Permit No.
I
j
r Project Name
j . Address /a Inc ke 1 Suite # /o Y
1� Retain current inspection schedule
Needs shift inspection
Approved without correction notice
Approved with correction notice issued
Sprinklers:
Fire Alarm:
Hood & Duct:
Halon:
Monitor:
Pre -Fire:
Permits:
Occupancy Type:
FPO `/ - -
Authorized Signature Date
Final Approval Frm Rev. 5/2/03 T.F.D. Form F.P. 85
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206 -575 -4404 • Far: 206 -575 -4439
.
z .
�
mo w:
u�l �
UO
CO)
J
H
D U_
W
LL
a .
N �
=
�o
zF
U
N
=U
LL ~O'
w z
U
CO)
O ~ _
Z..
2003 Washington State Nonresidential Energy Code Compliance Form
Project Info
Project Address BENEFICIAL FINANCE
Date 6/22/2005
415 BAKER BLVD., SUITE 104
For Building Department Use
RECEIVED
CITY OF: TUKWILA►
,• 1:; e'. "
J
PERMIT CENTER
TUKWILA, WASHINGTON 98188
Applicant Name:
Applicant Address: IN
Applicant Phone:
Project Description 13 New Building Addition ® Attera ion Mans Included
Refe WSEC Section 1513 for controls and commissioning requirements.
Compliance Option C Prescriptive Lighting Power Allowance Q Systems Analysis
(See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.)
Alteration Exceptions
(check appropriate box)
Q
No changes are being made to the lighting
Q
Less than 60% of the fixtures are new, and installed lighting wattage is not being increased
Maximum Allowed Lighting Wattage (Interior)
Location
(floor /room no.)
Occupancy Description
Allowed
Watts per fe "
Area in ft'
Allowed x Area
WHOLE BLDG.
RETAIL BANKING
1.5(
1769.
2653.
103,104,108
2 X 4' PRISMATIC TROFFER, (3) F32T8,BLECT BALLAST
5
93. (
837.
Open Parking
0.2 W /f?
From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Wa
2653 .
Noies:
{ 1. Use manufacturer's listed maximum input wattage. For hard -wired ballasts only, the default
table in the NREC Technical Reference Manual may also be used
2. Include exit lights unless less than 5 watts per fixture.
t Proposed Lighting Wattage ( Interi Ist all fixtures For exempt lighting, not exception and leave Watts/Fixture blank.
Location
(fioodmom no.)
Fixture Description
Number of
Fixtures
Watts/
Fixture
Watts
Proposed
101,102,105,106
2' X 4' PRISMATIC TROFFER, (4) F32T8,ELBCT BALLAST
1
114.
17 10.
103,104,108
2 X 4' PRISMATIC TROFFER, (3) F32T8,BLECT BALLAST
5
93. (
837.
Open Parking
0.2 W /f?
Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watt
5 2547.
Maximum Allowed Lighting Wattage4ExteriUr)
I
i
i�
Location
REVIEW-_L
CODE 'QMp IANCE
° Description
Allowed Watts
per fe or per If
Area in t f
(or If for perimeter )
Allowed Watts
x fl? (or x If)
Covered Parking
(standard paint)
1'- f"N" V^
`
0.2 WHIF
Covered Parking
(reflective paint)
J U L r7 Z�Q
U +�
0.3 W /f?
Open Parking
0.2 W /f?
Outdoor Areas
_ -
0.2 W /ft
Bldg. (by facade)
/ (1� -} ! �l/lll %
0.25 W/ft
Bldg. (by Perim)
, :� }�..: E i`'?t.,� i V L: t . ;t'i, '.
7.5 Wif
Note: for building exterior, choose either the area or the perimeter method, but not both) Total Allowed Watt
vse "119F 115teu inaximurn input wattage. rur nxwies wnn naru - wueu uanasw unry, i
Proposed Lighting Wattage (Exterior) default table in the NREC Technical Reference Manual may also be used.
Location
Fixture Description
Number of
Fixtures
Watts/
Fixture
Watts
Proposed
Total Proposed Watts may not exceed Total Allowed Watts for Exterior Total Proposed Watt
Z
Z
�w
QQ
JU
U0
CO
W =
t—
U) LL
w
Q
to
I. W
Z
H O
Z
w
U�
. N.
� f^
WW
H
U.
.. Z
W
CO)
O
Z
A, 2003 Washin
State Nonresidential Energy Code Compliance Form
2003 Washington Slate Nonresidential Energy Code Compliance Forms Revised July 2004
Prescriptive Spaces I Occupancy: 0 Warehouses, storage areas or aircraft storage hangers iD Other
Qualification Checklist
Note: If occupancy type is "Other" and fixture
answer is checked, the number of fixtures in
the space is not limited by Code. Clearly
Indicate these spaces on plans. If not
qualified, do LPA Calculations.
Lighting Fixtures: 0 Check here if at least 95% of fixtures in the space meet all four criteria:
1. Fixtures are fluorescent, non - lensed, with only one or two lamps, and
2. Lamps are T -1, T -2, T -4, T -5, T -6, T -8 3. Lamps are 5 -50 Watts, and
4. Ballasts are electronic ballasts 5. Exit lights < 5 watts /fixture
6. Screw -in compact fluorescent fixtures do not q ualify
TABLE 15 -1 Unit Lighting Power Allowa (LPA)
Use
LPAz
(W /sf)
Use
LPA
(Ulf /sf)
Painting, welding, carpentry, machine shops
2.3
Police and fire stations"
1.5
Barber shops, beauty shops
2.0
Atria atriums
1.0
Hotel ban uet/conference/exhibition hall '
2.0
Assembly spaces auditoriums, gymnasia heaters
1.0
Laboratories
2.0
Group R -1 common areas
1.0
Aircraft repair hangars
Cafeterias fast food establishments
1.5
1.5
Process plants
Restaurants/bars
1.0
1.0
Factories workshops, handlin areas
1.5
Locker and/or shower facilities
0.8
Gas stations, auto repair shops
1.5
Warehouses ", storage areas
0.5
Institutions
1.5
Aircraft storage hangars
0.4
Libraries
Nursing homes and hotel/motel guest rooms
1.5
1.5
Retail retail banking
Parking garages
1.5
See Section
1532
Wholesale stores (pallet rack shelvin
1.5
Mall concourses
1.4
Plans Submitted for Common Areas Ont
Schools buildings (Group E occupancy only),
school classrooms day care centers
1.35
Main floor building lobbies' (except mall
concourses
1.2
Laundries
1.3
Common areas, corridors, toilet facilities and
washrooms elevator lobbies
0.8
Office buildings, office /administrative areas in
facilities of other use types (including but not limited
to schools" hospitals, institutions, museums, banks,
churches
1.2
Footnotes for Table 15 -1
1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not
mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based
upon the most comparable use specified in the table. See Section 1512 for exempt areas.
2) The wafts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically
directed otherwise by subsequent footnotes.
3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet.
4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly.
5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet.
6) Includes pump area under canopy.
7) In cases in which a fighting plan is submitted for only a portion of a floor, a Unit Lighting Power Allowance of 1.35 may be used
for usable office floor area and 0.80 watts per square foot shall be used for the common areas, which may include elevator
space, lobby area and rest rooms. Common areas, as herein defined do not include mall concourses.
8) For the fire engine room, the Unit Lighting Power Allowance is 1.0 watts per square foot.
9) For indoor sport tournament courts With adjacent spectator seating, the Unit Lighting Power Allowance for the court area is 2.6
watts per square foot.
10) Display Window illumination installed Within 2 feet of the window, lighting for free - standing display where the lighting moves With
the display, and building showcase illumination where the lighting is enclosed Within the showcase are exempt.
An additional 1.5 We of merchandise display luminaires are exempt provided that they comply with all three of the following:
a) located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall).
b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with
two points of track attachment).
c) fitted With tungsten halogen, fluorescent, or high intensity discharge lamps.
This additional lighting power is allowed only if the lighting is actually installed.
11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be
defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face
area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by
racks.
Z
�Z
W
QQ�
0
N o
CO W
W =
H
CO LL
W O
LL Q
to
Z d
�W
Z =.
F-
I- O
Z i-
W
U�
O N
ID �
WW
� U'
U_ 0 .
L1J
Z.
to
H F=-
O
Z
t
.L 2003 Washin ton State N
Li ghting Pe rmit
2003 Washington Slate Nonresidential Energy Code Compliance Fortes
Code Compliance Form
Project Address
BENEFICIAL FINANCE
Date 6/22/2005
The following information is necessary to check a lighting permit application for compliance with the lighting requirements in the
1994 Washington State Nonresidential Energy Code.
Applicability
(yes, no, n.a.)
Code
Section
Component
Information Require
Locatio
on Plan
Building Department
Note,
LIGHTING CONTROLS (Section 1513)
yes
1513.1
Local control /access
Schedule with type, indicate locations
E -2
yes
1513.2
Area controls
Maximum limit per switch
E -2
yes
1513.3
Daylight zone control
Schedule with type and features, indicate locations
yes
vertical glazing
Indicate vertical glazing on plans
E -2
r..
overhead glazing
Indicate overhead glazing on plans
r • a •
1513.4
Display /exhib /special
Indicate separate controls
1513.5
Exterior shut -off
Schedule with type and features, indicate location
r • a •
(a) timer w /backup
Indicate location
r • a •
(b) photocell.
Indicate location
1513.6
Inter. auto shut -off
Indicate location
r • a.
1513.6.1
(a) occup. sensors
Schedule with type and locations
r.. a.
1513.6.2
(b) auto. switches
Schedule with type and features (back -up, override capability);
Indicate size of zone on plans
4
1513.7
Commissioning
Indicate requirements for lighting controls commissioning
E -2
yes
Lighting Sum. Form
Completed and attached.
Schedule with fixture types,
lamps, ballasts, watts per fixture
ALSO
SEE
E -2
r.. a.
Elec motor efficiency
MECH -MOT or Equipment Schedule with hp, rpm, efficiency
If "no" is circled for any question, provide explanation:
Z
i= Z
�W
QQ �
JO
UO
Nc
U) UJI
J=
fH
IL
W O.
UQ
N d
= W
H
Z
1_ O
Z H
W Lu
U
O CO.
� F-
WW
H
�O
.. Z
W
U
CO
O
Z
i
1908
July 13, 2005
;y City of Tukwila
Steven M. Mullet, Mayor
•'� Department of Community Development Steve Lancaster, Director
Doug Poeschel
PO Box 6315
Federal Way, WA 98063
RE: CORRECTION LETTER #1
Development Permit Application Number D05 -220
Beneficial Finance – 415 Baker BI
Dear Mr. Poeschel:
This letter is to inform you of corrections that must be addressed before your development permit(s) can be approved.
All correction requests from each department must be addressed at the same time and reflected on your drawings. I
have enclosed comments from the Building Department. At this time, the Planning, Public Works and Fire Departments
have no comments.
i Building Department: Ken Nelsen, at (206) 431 -3677, if you have questions regarding the
( attached memo.
Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or
other documentation. The City requires that four (4) complete sets of revised plans, specifications and /or other
documentation be resubmitted with the appropriate revision block.
j In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have
enclosed one for your convenience. Corrections /revisions must be made in person and will not be accented through
i the mail or by a messenger service.
If you have any questions, please contact me at (206) 433 -7165.
Si cerely,
i
Brenda Holt
Permit Coordinator
i
encl
xc: File No. D05 -220
i
4
PAplanning %rendAD05 -220 — correction Itr N l.doc
bh
6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax. 206 - 431 -3665
i
Z
Z
Ui
3
0 0
CO) =.
t`
N U.
w 0
U—
= CY
E.. w
Z�
F- o.
LU5
� o
W w :
U
LL ~O
ui Z
U=
O ~.
Z...
Building Division Review Memo
Date: July 11, 2005
Project Name: Beneficial Finance, permit application
Application #: D05 -220
Plan Review: Ken Nelsen, Senior Plans Examiner
An initial Building Division plan review has been conducted on the subject permit application. Only one item
of concern has been noted at this time. Please address the following comment with revised plans and/or other
applicable documentation.
1. The new location for the rear egress door #106, will swing into the existing hallway and may project more then
allowed by IBC Section 1008.1.2. Revise the direction of the door swing in toward the space, or relocate the door
to a location that would not require it to project in to the hallway's clear width and accessible maneuvering space
per IBC Chapter 11.
No further comments at this time.
Z
Z'
LU
JU
UO
U U.
wi
J f'
U-
0
J.
a_ Q
co d'
=w.
i-- _
z�
Z
W
2 5.
U
;O
w w`
H U
i6 �.
..Z
U N'
O � .
Z
,- 1
PERMIT COORD COPY
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: D05 -220 DATE: 7 -13 -05
PR03ECT NAME BENEFICIAL FINANCE
SITE ADDRESS 415 BAKER BL
Original Plan Submittal Response to Incomplete Letter #
X Response to Correction Letter # 1 Revision # After Permit Issued
DEPARTMENTS: -oS
Buijing Di iv sion Fire Prevention ❑ Planning Division ❑
j e
Public Works ❑ Structural ❑ Permit Coordinator
. DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 7 - 14-05
Complete d Incomplete ❑ Not Applicable ❑
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TOES /THURS R UTING:
Please Route Structural Review Required
REVIEWER'S INITIALS:
❑ No further Review Required ❑
DATE:
APPROVALS OR CORRECTIONS
Approved ❑ Approved with Conditions
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents /routlng slip.doc
2 -28.02
DUE DATE: 5-11 -05
Not Approved (attach comments) ❑
z
. �z
}' w
o aa C 2
WU
00
ND
C0 W
J
S2 LL
w
U- Q
�
i .-w
z
Z0
LLJ W
U o
O (1)
OH
w w
LL
Z'
UN
F
O ~'
z
PLAN R SLIP
ACTIVITY NUMBER D05 -220 DATE: 6 -28 -05
PROJECT NAME BENEFICIAL FINANCE
SITE ADDRESS 415 BAKER BL, SUITE 104
X Original Plan Submittal
Response to Correction Letter #
Response to Incomplete Letter #
Revision # After Permit Issued
DEPARTMENTS:
� S: t / � 4w(, N o-3o
9
Buildin Division Fire Prevention P Pan ni Division
Publi Works Z Structural ❑ Permit Coordinator
DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 6
Complete d Incomplete ❑ Not Applicable ❑
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TOES /THURS RO TING:
Please Route Structural Review Required
REVIEWER'S INITIALS:
❑ No further Review Required ❑
DATE:
APPROVALS OR CORRECTIONS
Approved ❑ Approved with Conditions ❑
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg N, Fire ❑ Ping ❑ PW ❑ Staff Initials:
DUE DATE: 7-28
Not Approved (attach comments) E�
z
Z
w
u� D .
�U
UO
(/)
W =
F—
N LL
w
9a
�d
=w
z �.
�o
w ~
w
U
CO
C3 I--
w
ti 0
..z
w
U=
O~
z
City of Tukwila Steven M. Mullet, Mayor
Department of Community Development Steve Lancaster, Director
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
`'` ` REVISION SUBMITTAL
: x
Revision: submittals must be submitted in person at the Permit Center. Revisions will not be accepted through
the mail, fax, etc.
Date:
7____r
= /3 .— � Plan Check/Permit Number:
Response to Incomplete Letter #
0 to Correction Letter #
❑ Revision # after Permit is Issued
❑ Revision requested by a City Building Inspector or Plans Examiner
Project Name:_
Project Address:
Contact Person:
Summary of Revision:
e �f -.�
Sheet Number(s):
"Cloud" or highlight all areai of revision including date of revision
Received at the City of Tukwila Permit Center by: 1 E 6 4
AL RECEIVED
Entered in Permits Plus on CITY OF TUKWILA
app ications orms- applications on line evision submittal J U L
Created: 8 -13 -2004
Revised:
PERMIT CENTER
z
Z
�W
JU
UO
0
W=
H
C0 LL
w O.
�Q
T d
3:
Z
F-.
Z0
W5
U�
co
0 1—
w
I-- P',
LL
.. z
w
CO)
O
z
Look Up a Contractor, Electrician or Plumber License Detail
Washington State Department of Labor and Industries
General /Specialty Contractor
A business registered as a construction contractor with L &I to perform
construction work within the scope of its specialty. A General or Specialty
construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
License Information
License
RIVERCCI170B
Licensee Name
RIVER CITY CONSTRUCTION INC
Licensee Type
CONSTRUCTION CONTRACTOR
UBI
601139256
Ind. Ins. Account Id
Business Type
CORPORATION
Address 1
PO BOX 6315
Address 2
Cancel
City
FEDERAL WAY
County
KING
State
WA
Zip
98063
Phone
2539394545
Status
ACTIVE
Specialty 1
GENERAL
Specialty 2
UNUSED
Effective Date
9/2/1989
Expiration Date
6/6/2007
Suspend Date
Separation Date
Parent Company
Until
Previous License
RIVERCC210134
Next License
Associated License
Business Owner Information
Name
Role
Effective Date
Expiration Date
DOWN, ROBERT H
01/01/1980
DOWN, DIANNE L
01/01/1980
Company
Bond
Information
Bond
Bond
Company
Account
Effective
Expiration
Cancel
Impaired
Bond
Received
Bond
Name
Number
Date
Date
Date
Date
Amount
Date
TRAVELERS
CAS &
Until
#4
SURETY CO
206853225
09/02/2001
Cancelled
$12,000.00
08/10/2001
Page 1 of 3
Z
W
JU
U O
CO t]
J y
H
NLL
WO
J
U. Q.
N d
= W
Z �.
Z O.
W
5.
U �
O N
� F-
WW
H�
�O.
. Z .
W
O
Z
https:H fortress. wa. gov /lni/bbip /printer.aspx ?License= RIVERCCl 170B 07/25/2005
`'I
SIPARATE PEttMI'�
WA%m FOR:
PhxnNnQ
d/ Gas Plp'nj
Cry Of TL
BUIWI G DIVISION
( ADAMS AUUHGROYY
1(206) 431-3670
A RCHOVECUUREP.C. 0 CODES I550 N NORUHWESU I
BErL`AEF0C9AL FONANCE
45 BAKER BLVD, SUffE �04
Do
TUKWgLA 000
, WAO 9M
[�IIImti� \III[] \A
pwna N&ITMs liplo
phn iewkw apprmW is subW to errors and orrti skm
4PV4 of cm to cdon dow wilts does not ate
ft of any Or *A 1-T KIIIIII
a approvW Reid Copy mnd ft
ay of
Nklk AmAVAmILa:LE
AIm IZI I LI (I 111) CEOUNG
PLAN a" LEGEND
AImI3. FUU'm%NOYUnME/ FONOSH ufl-ILAN
SCHEDULES & DEUABLS
LOCATION INFORMATION � � � SITE PLAN
SME
U"Y E
P3iVd'0NA Ck 9'ru*769
(tvqY9) 397==3004 p'Afl
397 iAx
HFC PROPERTY ENT
1
mm
No ch meges : be mob to tM occF I
e' vic 7! : At ha t prior a'pprOvAd Of
c .�:E`.vi� Bid Q�1/�510rl.
-.::.is �Ari!
{} r rt • o p '�n
ar ± r-E y w..u� fJ�/ to al pl- S. i C .•. ..~ �5.
G ROSS S.F.09 - ----------------------- 1.800 ST.
.CKo"CUPANU LOAD; MtEA-- 1.8W SLF-
• • L OAD
lepMsm
EGRES&
• 1 Nm
EXff 1 • t
ARCHITECT CODE REVIEW
t0
`' Ssy► . o i� :
60Cft
T. a diL, :.
•Vl
`
it • �
-
i
t
E tiar ow e s
e
= _
G ROSS S.F.09 - ----------------------- 1.800 ST.
.CKo"CUPANU LOAD; MtEA-- 1.8W SLF-
• • L OAD
lepMsm
EGRES&
• 1 Nm
EXff 1 • t
ARCHITECT CODE REVIEW
DOMENSdON PLAN
SCHED n DETAOLS
E
ELE-C UROCAL PLAN
PANEL I
LEGENDS n ELEVAUBONS
140 Iff \ , •�\
I�
T�5•?20
DRAWING INDEX
♦ SIM
ho
W�
C3 0
Z
Q w
Z
w
CO
Q i
—iQ
11MLw
W Y —
Zm
w��
�0
V�
"
�O
Q W 46
a �
0.
�to�
Q �- =40 40
Z -um U.
Lu 3 o
0
CL Z .O a
V ZWN rL
_aeo
'
V4 o
tbd�
FMI
7 I�i�IS��II
ca
.
d
C
d
m
H
W
W
Z
W
O
U
Revisiar s
0
O
O
O
D
0
= ♦R f0
V w wMEX - E - 4 SIM :ar. • .r- �►. is s
V;i» - 0" w -'Vo NMIM 3w maw
WR ar"G *c SgkxT%pn out
OP411111110'*
Or!
AS NOTM IMPOLE
ift
05�2208
Smm%
cs.mi
4
3
i
•Vl
`
I�
i
DOMENSdON PLAN
SCHED n DETAOLS
E
ELE-C UROCAL PLAN
PANEL I
LEGENDS n ELEVAUBONS
140 Iff \ , •�\
I�
T�5•?20
DRAWING INDEX
♦ SIM
ho
W�
C3 0
Z
Q w
Z
w
CO
Q i
—iQ
11MLw
W Y —
Zm
w��
�0
V�
"
�O
Q W 46
a �
0.
�to�
Q �- =40 40
Z -um U.
Lu 3 o
0
CL Z .O a
V ZWN rL
_aeo
'
V4 o
tbd�
FMI
7 I�i�IS��II
ca
.
d
C
d
m
H
W
W
Z
W
O
U
Revisiar s
0
O
O
O
D
0
= ♦R f0
V w wMEX - E - 4 SIM :ar. • .r- �►. is s
V;i» - 0" w -'Vo NMIM 3w maw
WR ar"G *c SgkxT%pn out
OP411111110'*
Or!
AS NOTM IMPOLE
ift
05�2208
Smm%
cs.mi
4
3
i
Djq�
1 N 88'25'27' W
252.66 LEGAL DESCRIPTION
BAKER BLVD
i
Goolowilm
F 354.10 NORTH LINE TRACT 8 173.3'4' 10' UTILITIES EASEMENT PER PLAT
E
p = 89 I
R = 50.00'
L = 78.11'
------- ------------------------------------------------------
I
` I
I ` I
NORTHWEST CORNER
TRACT 8
��J
�`<
• t ' `� E E
r
I RANDOM SPACED � ET
_ -w -- PARKING BUMPER
r - - BLOCKS -L
I _ y _ 60' GUIDING SETBACK UNE PER PLAT
SCALE 1' = 20'
0 20 40
sow
n: `• �._S• = �;.- S 1 � L ��^^' - � = -
re
jLwr
Truck
RENTON
TU-K ILA
• F ' .. M me_ 1 a � I � ' ��.4� F `•� 1 �• � �
• � : ....tee_ _ -� - _ r
sr
VICINITY MAP
I h���
I � a I 1 ! 1 I I __!•_.__ I
o I HANOI -CAP v � %a H e
1
RAMP
11 .01
I ---- ____ -- 1.0 I I I I I 1 I I I
I - "•; • • • • ,i •: CONC. WALK _ , ,-- • 1 ', •,' •.•
_ ,,• , .,
. ..., 71.51 -_
• CON C. i = I ' • �, i I
I (.' SLAG •'.,• m I I
• GATE I
_ -- 45.00
1 HANa -CAP
EXISTING BUILDING 4.19 RAMP
• E XISTIN G G GARAGE �=
-- -- -- 2 - STORY BRICK : •
0 I
° 1 - STORY BRICK ` :I .: I
N •: 2- sTOR`r
OVERHANG
45.03 4.19 co wM
W-- - --- -_
to I I
°
OR
M •• I I co
GAS METERS (2)
71.48 .
• I
- -- E1.FCTRIC EASEMENT T
L : AF 8807111069 j 1
I I
I 1 �
SOUTH LINE TRA 6 � s � f
r IIIIIIIIIIIIIIIIIIII
NORTH LINE TRACT 9 + .- C _ 1 I I 1 ! ! 1 1 1 1 I I 1 1 I r r r r I I
SLAB
! �•- •..- -•" � 1 1 1 I I 1 ! I 1 1 r l I 1 I
• I
N 88'25 W 224.93'
0
CHA,N LINK FENCE (TYP)
LEGEND
.0 Fo M CASE IMM
G 51 OR#1 CATCH SAM
FEE wfiwj T
WA7ER IEIM
ELEOTRlC vm&T )
CT mmww 'm
Er IRSER ON COWo. PAD
4
co
no.
REV I S I OHS
CE I aT i ow
m
U
c.i
0
U
to
❑S
SURVEYOR'S CER11FICAlION
L GORDON T. PA71MAN1. HII�REBY CER1F7 10 1FE OF
FORE5IERS SEATTLE MORTGAGE Ca1PAllY NO 7RANSr1ME30CA TITLE INSURANCE
CQWAN1f THAT 1HS WP IS A 7RIJE 1110 ACT REP�lITAl10N OF A
SlJR11Elr MADE BY 1E OR UNDER MY OIIiEC'T RESMISINUTY. 7a THE BEST
OF MY 9140KED6E AND BELIEF, ALL DiQ190NS AND LOG11106 Sfi0M1
HEREON ARE llllE AND CORRECT /ICOQIDN6 70 FIELD IS
MADE SEPT. 219 1991 AT 7FE REQUEST OF 9aLY DEY. CO.
4 24 - 9 -'s1 •l 1
6RD01 T. PA7FYAM1. P.L..S, 1801e p,AW
R OJI sy
IoInTE .
-
PATHMANN SURVEYING
v ; LAS SUWU SPECIALIST
- - - -~
w u%w l m
a.Ex
SOILY DEVO CO.. INC.
RMACT
ROYAL VAJLFF SIZE AS -BUILT
OYim or GT'p ORTE 911-27-S r A mD 63.06
C7EOIED Ir GTP 9GLE (. = x . 9EEF ( OF
r
t
E
I
s
i
t
i
i
Kol
THAT PORTION OF TRACTS 8 AND 9 OF ANDOVER PARK NO. 2. AS PER PLAT
RECORDED IN VOLUME 71 OF PLATS, PAGES 88 AND 69, RECORDS OF KONG
COUNTY, DESCRIBED AS FOLLOWS:
BEGINNING AT THE I NORTHWEST CORNER OF SAID TRACT 8; THENCE SOUTH
88 25 EAST ALONG THE NORTH LINE OF SAID TRACT 8, A DISTANCE OF
354.10 FEET TO THE TRUE POINT OF BEGINNING; THENCE SOUTH 01 3
WEST A DISTANCE OF 235.00 FEET; THENCE SOUTH 88 25 27" EAST A DISTANCE
OF 224.93 TO THE EAST UNE OF SAID TRACT 9; THENCE NORTH 01 05'06"
EAST ALONG SAID EAST UNE A DISTANCE OF 185.43 FEET; THENCE ALONG
A CURVE TO THE LEFT HAVING A RADIUS OF 50.00 FEET AN ARC DISTANCE
OF 78.11 FEET THROUGH A CENTRAL. ANGLE OF 89 30'33 ; THENCE NORTH
88 25 WEST ALONG THE NORTH UNE OF SAID TRACT 8 A DISTANCE OF
173.34 FEET M THE TRUE POINT OF BEGINNING;
SITUATED IN THE CITY OF TUKWILA, COUNTY OF KING. STATE OF WASHINGTON.
SUBJECT M AND/ OR TOGETHER WITH THE FOLLOWING RECORDED
EASEMENTS:
A.F. 8807111069, FOR ELECTRIC SYSTEM (AS SHOWN)
RECORDED PLAT, FOR UTILITIES (AS SHOWN)
.4
NOTES
I.
THE LEGAL DESCRIPTION AND EASEMENTS SHOWN HEREON ARE PER A
I
TITLE REPORT BY TRANSAMERICA TITLE INSURANCE COMPANY, ORDER
NO. 0860964 SUPPLEMENT NO.1 DATED SEPT. 10, 1991.
2.
THIS SURVEY WAS PREFORMED WITH A LIETZ THEODOLITE AND EDM.
-
3.
UNDERGROUND UMU71ES NOT SHOWN ARE UNLOCATABLE.
W
4.
THE PROPERTY SHOWN HEREON LIES WITHIN FLOOD ZONE "X". AREAS
'FW
C/)
OETERMINED M BE OUTSIDE 50Q -`YEAR FLOOD PWN, PER
<
MAP 28 D. PANEL 328 OF 6,504, DATED SEP 1 29,
W
0
1989.
in
IrIM DATA:
�
0
o
SITE - 415 BAKER BLVD.
a. Q
I Z
WA -
AREAS - PROPERTY 52.095.3 SOFT.
BUILDING 6.4610 SQ.FT. (BASED UPON EXIERIOR DRI NSI(M)
�
PARKING SPACES (PAINTED)
_ 79
j
HANDI --CAP- 1
0
UNUSABLE - 3 (FENCES IN WAY)
0
TOTAL - 83
Z
1
Q
t0
.,
Go
-,� CJ
1
30
.4
_ .
W IL T- up . me - ,�• T op' ' QR' 14AR'�'
.- . SU ILT- UP RODE
c
. , ,• . yr GvL .. � ..
COL.
'. .. .: ; , • • _� � ', -, • , -_ : ; •. ..' . , : . � - .- '- •, ' _� , . • .. � .. , ' .. ... ;
_« �► _ �. 16TE6L JOIST!
• . '" ALL.., SUfir. GEILIhi
_n
• 1,� _ t�•:! .1 _ ,: s ': r tG - ----- 11" 0� - ��- .. _.._ - fP C
2EE 1w ® 17 Zi► '!i - : 9'
PI C'S _ . - 'FLAB INt✓ GOttt►1TlR boLTs . iYP.
C� O' - s e N .
F6•A' Iwo C t�'AINTI D
tt " TOP Of
4 Ub. D" A . GYP. bp.' �. - , ,:: -. •, - _ _._ , .
r A ' :�'L:IZ. ~ »= �•' t>�I. tip. lam- _ _ bai.D, . __ Go1�1G..f LAb -- 4 1106 , bAS! bu ILT uP tacooF
44t�,` UAID
GOL. GOL . _ _ - - JOISTS
L _ T1 �•:� -- STEEL (PA+ 'w
suer. '011LINd a G�:'o►. :s;
. :. o.
A LL
• + t ,
L
1 , •' ,
GO G
DO E
_ 1• ) R �1 L MALL
!#iKIST r -
�qA E b.d.D. ,'et .. �► ,,' �; .:. . , II .� 11 110' � I I �� '� •_ E%
=-4 Rub. lSA6 .--- - •o d .r , . r. _. SLOGIC
j2 • OIIGT • , .. ,- '; _ �:�: .,.. � LT
I! r'ERI !T!R uo PUCT P : = lilC ► T .. -,; t1!�;I��T I l 4 4"(- SLAE►•P1TG1� To pR�►I�I aw
' vRAni MM _ Z7•• 4� -� , ,....... Z9 ... - .. �!- t'EltlM Tea 1 .. -
II�SU ' - • . - .I' .__ :.,.PQRI�11Q' INfLtLATIiQN''' _ 0 5 I ,
1A•3 - .. - - . _ _ .. ., - - • '.. _. - .:' I�I _ .. .. - .. INEt1L•A� ION.. ' � GoMP'AGTSC�
. . ' • - ... . - .. .. � .. . - ... �` 1111$ ... _ • FIIJ. GRAt�E
• - - . ... r • . _ � ' . .. :, _ , - .. ,, • : - .. .�. • , • .. -, • - _ _ .. 2 'LAYFrs ol� �.A�a oN :y � y •
SACT /0Al
Q /4 - G T N "• IZ.I -p� TRI1NSFORMER * SrIITGN GUil64�t s+1�
P
. - _ SE I o.
..S CA L E . �/� r s �:, �i • . - - i a i �� o PULL Soy( Uwoffsz4Ro
NOT! b�✓M GOM
. � - - - - - ' •.. . - - - .. ', ...- .. . • . .. - - - . .� • � �= •sciz s • . . is . _; � - o.. .. .. .- . � • ' .
: um NRlGAST
• • • _ • . • . - :. ' ' .. . • : ., � • • - ' - _ =: _ :. .,. :'. }� - _ . • •CON�R rA0 RoR !<oRM R
• . - WITGN CUSICL! 1•URNISNED 4- INSTALLED
A ' F�ta/!R co. G.tNeRAL GvwT ToR
' - ' °' • " _ ! "1'n VlRll� GrcTENT OF NIS Wb171CAowOa o.
_ Itv -4:
,..., - , II ,{
-a .� •iO 3 a -O -� 3. a Z a a 4'- 0
q -
4 ► a t .
.. _ 3 Id 3 4 b .� �� - =- - ' . •_• .,• _ . •• - - - -
Lr
- STAIR B 8'. SUP E.1. 5 P r -r ; _
M A - TAT 8.
.. .,: I
•., -., _ � - Z07 _ , _.. :, .I V. 1 MS N F• E tJ T'EL.E 1
_ 1:18•
t + _
I
o
w
. 1 'I •
F 1
7 V ep -
• 1_ r, -'' . r. •,
E T . : L• 1 1
ir
MOVAl3L6r. PARTITIONS 1J.1,G. - :,. .�, t �9 1
0 1~4 A i+ t I'I4 _ r
NAIL ---�L "
L
I _ .+ - W
,� t ESS+ i !i1De1VALK
- -
:-WO MEWS -
1
r � M T
- W • M �• I �i I O G
_ . PA T 1!R>f T
I i I I _ : ,' � e•, • � fotttld!• XLASN
r _
_ T � •{ z I
•t 3
t
I
00* - - _ _ >- .. 4�Z�h,. � Y �•- _ ='�o s. `ear:•.: �• .�_ �;.• '�_1 t__.1• :L 1 L.1 � - _ .
COL. Ht
r t, i - + -• a - I ti G O AC C. A r /J u ny Q clot
_ s .1�OF . _ _ ,- . �-.' W.W. F. I
'1 - --
f
r' I `T F . i 1
'.
.I r - f • _ . , -:, _ ..: .: • •1: I `I� I t I L-U et N_ - M. ... .. • t
1 ,
l I r 1
�, I . t . I t _ : H.P. fiC10f• .: -1. l .� t
_ f _ I . _ . - I E 9a' �4 EL.2�4o 4or
ti i - i r - •+ NIC I
1 [Q �_�
L�. L_ � �. •.. _ f_
- z
'•=`j ';f D •r _ c : L_:1 L:. J- '1:�:� L_ -! , L'' I ,. c NTT+tAI•�Ct'.
ALL. D K N LJ
1 TC Trl >_ W • O" KS VA U AT N R
:- R14i
r • ..._
R. t _ -, o1i.
- i r FIN. RLR. EL. 8.40 ti
T` 3I b L ' fe 10 -=S'� . 9 s'
I ( !. I - 1•'•. ! 1 1St — —
-
IL
5 -
-
I I _I I '� f I -- ;, _ ••:- -, _ ..;, - •�_' � - 1- 1 _1 '� I I• 1 - bw -• _ �' A "�I' - • •� _ o - -
_ , _ ,' 204 'Cf: i� _ .. z 1 ,• :�
G E W E RA L O F F i [ E o v :.• .. :�- : :.R _ _ _ i .. �; •• ,
- - - � r• _ ..:: - - :�•• ,. � -� -#, � _ - SLOPE ,- SLOPE
F _�. _ '3 0
_ • � � _ = FIN. LR. 4t? ..
r r i r J t _ t
t►--- 1A - i _ 1 -
- - • I t - � :• -- . ��': . _ .. - - - � - ,FLOOR EL-2
S.Z4 _
GotrF• �Cd.S G F
o _ r
I - 1 _ - I t -1 - I . • t - � t - . , ;- . _ - ' .��- -� , - - 29 : . - • I. I ; •I . • I . • WW _• Y � � n
I s I COT.
• I t I i I I i ) I iRlw E - E IE
C OL. L _ 1 L_J L -..! =�_ I _�! L 1 �L _1 L__i L_! 'o• . I ,
•� _ _ I _ L '.J L_ 1 L__ i L __I L _ 1 C.� - I •��: _ r M r «o
tac - _ - - r - - - - - ' Z� �Z�
c oc . _ :7 �9 =--e- Writ: EVALUATION AREA 15
I = DRIVE TNRU DAMAGE r
-� t- -� ' - . #- r --� «- f' f *": - _ _ . - - , - - s t T *STIMATIQO OWW. NO PARKIN& l
1 i - ! ! : f _ HALL I REPNIRallo OR STORAbt PERMRTED.
. fF =t - 1 I I I I_ I I I 1 [ s 24 ; _� b •rls
I I l j I I I 1 �= N:P i Ql��• i • - - . 1 *: 0 34 12� • 3. L.2A.40-� 40
L 1 L_'1' L' _J L_ 1 - -_ 1 L 1 1 ��� L;_1
22 -4 7+4' -Sr Z'1'•4 _ ': 1 1
• _ - - /'• - _ '1�• L• ,' - -• ',• -•' • - - - •= - . - , MWO *Li�.TRIG. IPLAl11 • I. _ _ ,- - -_ - t ! L - O -� ,
r _ _ _ _ a_ _ _ _ Y s _- • - �: I�OR- - CEILING -�iR1D MItTTERIr ; t MootD - E,5 i •'' 1
r 1 t- Z l r T r ` E r : �` =�� s '� _ _--- : �= -- .r - raft W& • _ ' I -
I
- I � 1 I 1 1 , ;, :. _ -.. - - _ _ '',. , _ _ �•- -' -"" -� - I 1 ! 1• 1 , I -t' • � �• - - .t - :' - RECCE �' i 0'%l � t - � I• . � , � - , , r � � t
i 1 a'� -4� A -O Z -S •0 9 -O
-, L + i �� _ - 1._ _•'_ _� 1 - _ 1 a Z ` �•8 -0 3
L _1 L_J L_ l_ �_� t.�J �_� ;, L_� L_.� L_J •.,� :_ _ _ •; L_ L_� �._� t' L.� -j : - ? 1 2' 4j
REFEit T4 EL�LTRfG "rLA1�1 - • _ "R +� _ , .. • - _ - = ! - �- - f G�iiG11 i�pr►artp qi ' . _ t I 1 ! -
_FOR CALM&.' &RIO ftT'rEbN -•: - .. - _ _ _ iAIItT iN _ T
• - - - 1 - -� _ "- - • _ - _ • - : _ _ • ' _� - , Y _ •• M .• �. • _ •� ` � i l •- � � - '• j 1o' -gam' � 1 I•T" I � � • �'•�' _ " �+ ` ' � -.
f �- 1 i I r 1 r- -� _ i ' , r , T' , - - _ ' - r r - _ �- - -, - - 1 - -= _ 1 �+ c o Jr C 4,
4 1
110 _' • = ;� vYV ! V. F. r�
1 • I : I I - TAI _, �� ' ! I I f 1 I I t :£ N T RY [ �� I R '��
L_ - L i _�-_1 t--;� . L_-� :.L_� L_� L_� Lis L_.:, 1 - - 1 _ . ' :__ L_� L__� } __� -' L_� '� D21 �: !
- -. _ .. ` - `' � � • � - 101 _ no - '• _ _ -
1 = • ♦ f
PtANT SPA C6 �-�• PL4ivr
W44 d 4r
4' -S' 4 3' ALdf 3L4• , 4L>b V-4
r
• v- - .. ...,.ter ,
t
,
TN+5 VRAw r 1&j 1S QE E
Vi5o E
` - _ - •- - _ - - •- _ A 5voERCEQF COp�£S 15SUE7
n4 i c 2 -o LATEST ;?EN11510 N
C 01V 40 - aF L O O R 4 A IV - SC A LE A /t o w t - _ _ - - �IR S 1 ,t�" L 0 oR X f A A �
I�
1
PC
V - l
c ��
Fc:A tw--,
.4
_ . _ _ - `_` ., ,. -_ -.� - _ .:•: -
`-
•
A�dr?EVI-AT10N S
4
yY%+1b0L5
- = - _ - t ' - , _ L . • . .. -
war w GONTRSLT
iVOiLK
'
ft.
GUMT I ON
Xaft.
+_
"m1 &ftATW
/MRTITIa1 To OF PLOD!
_ -- •- i _ _
C01�11G_
_
FOR woo "MI".
V ca ow
m
0amm sew
ftuft
Penn
P400TIM Cm
sea=
jhw uffraft
Abm
mot _ _. .. - _ •�_ : �- _�._� - _. �.� _ ., ` •► ` � _ ' 1 . - - •�� : . fj • . \. _ �►� - �ri�F � � ` _ ` .� . + • r i- � . !_ - w , � ' . _ •. �_ y, - f - .� {/ ... � �
• � _ � _ _ _ �► � w._.1 +r_ .- _ .rte. -►�.. ' _, " ,� i - ., . w_ �irraL< �`�• .. . � w -i � . _ ! _ . w _ _ `yt� • _ _ ` _ ., _ � a
e•.'
_
o
- . - -
- -
I�
1
PC
V - l
c ��
Fc:A tw--,
.4
qb
f ,
SID
'
if
'�. - '' ••l�l�t•�tt•• � ti+R ta TER ,
IL 71 � .
, IS :O
.r.1 ;• - . :`I• ; = � �, ' 1* POP RIVETS de 4AI L ; • .
VALL . "4 DE.
G SPACE. AT ALL
��. �• ' ..
ALL MUrtODCaS Cv•'C WAL ,,. i '` 4 j_ , V.,,jrR5 AT OvpOS I tp WALL
VERTIC STRUT PCIt U.n.C. ,7t 1C
1 P)q5. COMP4tlovr PER P1.CNUM A)EPTII.
Y
1 2 c.>tcr!► w61cm k s :: 4 4 '
• � M
2e wive ivkllw . 110� w4 Ir dr" I 'off • IJ
w
Alk
Go
a�. eta '
MJAV It. to" "%"
I0i4 jrAt e Q VUb h1AI
t i p
so
• •• • • .♦ • •• • •• ••, .� •• r ♦ I
V r I I I •I
• • , '
t ,
410
AT
MAIM IRV4W. R W-DO" (J.C- (Ory
cw MINIMUM
OF
•
G
zc
a Zys A.1E 1` �' k oV �TrG h Wu+►lr1KCT Q
•� M �; •
,Y' ''. •:,� ,, �.� •�' �• ---'�' 1 c AVGE s ptJ►YE O e+u►Cti�' wtRls . •K .s t VMP 94kL.L..
..« ,,,,1`_' , - •i� r ��• J• -• �' • /'+ .�..r•+• • . • (NOTE 1 1L2 ) mod •
wr
:L
_•. t .'• fir..i vp
0
, .: , : �. • ,,;.; r .�;�.. �•; .. .. . • ; ,+ . ', 1 Ji.- t ih� p f7 1,1 Ai 1 �� 1 �
'TEE f:0. v ' ' .:�' =x•1.,:,1 -, r
im
JI M u
•1
;j
IP *v (AV
N
ga 6.
4w Sit
few W_
top
,.� - �. _ +•.•..�- _. w —w_ -r �_ -w.. �� `- r•rrw _ .�.. . _ ._ �� ,•t •nr.. _. 4�- .. .. r _ r+M r r _ • ..• •� . -• t `
i
I'
I
f / +
I
I
- - s . ti ,� Y • .�nR -�
1
H
1'
r
,
1
r
i
,
01"elA OLva
RIP p,r r• r. r rl +r r r r.rr irr•+r.rr•r rrr
• Itr�r r�lrr �iw BAfi 'L'r : Ki eft^
�v,q t%tiO�R V41
.,• IZ. .i`.1& Fvft V 10 � repipi T
e a� u1�w UF
1�r 81
: - ' ' � . : ' • �,�,,3,4,g,� . • 3 r< fl g. L. � � , ..:�, � �Ah -s�, 2 PPS•• .. . ' ,
Im PONSsdl M Marc." ID i• a wIraw twa
al VOLAW 111i ' lime l 111 M an M . 00011101 w RtfO
y li0�i�>t 7 :L I, �, °j(8 ti as vvod mt:;� rwt' a, 2 M.
wIrl� i►t .!_ • W Mn low •t s 1 �uTT , I.�c- �:.•;�~T' l 1. v�R 1 1[`.�.�), I -1/1 1- ��T�P;
W1'"' un WAM = fit! iii M "to Ina • A off" ar f �. 1
!M •!0 A!t 10 w 1'R #01" M motilMt '
• l�Ct
01100011411 am A Btu M 211416111116 MT 1 1 -
M'wsw Im 10l11M M 224.601 pw !i0 l! W� LM 1p / 3 �° ��.G. lip t P. FtStAt E Z
law • s • • • K LK F'LATf� � L►�L� `. OIW
Isom Om h er a Wt At�rtw an war L= A DI rat w I SO. " vM9 ,
Isom MM • Mi� " M am NONSO • &am SO $6.00 N we Bc
gloom w "Oil A CMIUL An" GO 010162011112168
' 10 � 41 •r .rr! ARM = �11 LM a SAN sit • • 0t li r
298.06 pw 10 Un AMR MM M 01111�1111t G 0x ISTI r•ics :Tc.
y+�/ /��,��,r�� F..xry it; H • t-'f71. -• GAS -
40M : U�. W (M161 bfi6-0 4 WILT AX U06, ' &11
1
100k. &WL*JP PUZA S, cAAS raP. (ZOEPI 4-w- WMM umpw -m* M% mft)
DUI Ld �� '� � �- N � - . , . : • .
wW -Sl"G' WALL - xi t X11 -�•:ri =�c� C� t►•�LL
W4 4")P 6 A-L qlb u1J M RSA Oft �� ' W
F O*f 7
Z I } I 1 T� '► N•JD CA RY WALL So
_r
C"r I 1 I = ` _'" � -
- Exfw11� kP416 74 iE D1`MGt.ISN E
A _ -�
A tw} I I Ov PIJMXA
O JTLZT
'O 1 • M 1 ', O I �'- M I'�' 3� CO
10
O 0 o V ar �'�
1 �I•�CW W I u D+o�� ' yI LLr �: Cvl Er is r y =DAFT
oil ! 8 O ` AFF,
! • •
L-4
IF
s -
F L OOK -
•
�-� _. _._� _ �....�..� �..�. �_ - __ •� -� w. - +..�• ----� _� � s �+ _•••• S .. •- _� ... - � J•i� .. .f• i — � •�. � � : t . �. ♦ �r _ .► .► it •..� -.+• �qq!`•
1 _ ) -
q
c
GENERAL NOTES
1 THE WORK INCLUDES THE FURNISHING OF ALL LABOR, MATERIALS, EQUIPMENT
AND SERVICES NECESSARY FOR ANY REASONABLE INCIDENTAL TO THE
COMPLETION, IN PLACE, OF ALL WORK AS ILLUSTRATED AND DESCRIBED IN
DRAWINGS AND REFERENCE SHEETS AS PREPARED BY THE ARCHITECT.
GENERAL CONTRACTOR IS 70 COORDINATE THE WORK OF THE HVAC,
PLUMBING AND ELECTRICAL CONTRACTORS AS REQUIRED
2. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS SHOWN ON
DRAWINGS AT THE JOB SITE, AND SHALL NOTIFY THE OWNER IN WRITING OF
ANY OMISSIONS, DISCREPANCIES, AND /OR CONFLICTS BEFORE SUBMITTAL Of
BIDS OR RESPONSIBLE FOR SAME.
3. DO NOT SCALE DRAWINGS, DIMENSIONS GOVERN.
4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SECURING ALL REQUIRED
BUILDING PERMITS AND FOR INSURING THAT ALL WORK CONFORMS TO
APPLICABLE BUILDING CODES.
5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL FIELD DIMENSIONS AND
PROPER INSTALLATION OF SAID WORK.
6 THE CONTRACTOR SHALL REVIEW THE DRAWINGS FOR ANY DISCREPANCIES
AND SHALL REPORT ANY SUCH DISCREPANCIES AS MIGHT BE FOUND TO THE
PROPERTY MANGER PRIOR TO BID AWARD OR BE RESPONSIBLE FOR SAME.
7. WHERE SPECIFIC PRODUCTS AND MANUFACTURERS ARE SPECIFIED, THE
CONTRACTOR MAY USE AN EQUIVALENT, IF APPROVED AS SUCH BY THE
PROPERTY MANAGER IN SUCH CASES THE CONTRACTOR SHALL SUBMIT
SPECIFICATION SHEETS AND SAMPLES AS APPLICABLE FOR THE OWNER'S
APPROVAL PRIOR TO ORDERING
8. THE GENERAL CONTRACTOR SHALL HAVE DIRECT CONTROL AND MANAGEMENT
OF ALL CONSTRUCTION MEANS AND METHODS AND BE RESPONSIBLE FOR THE
SATISFACTORY OVERALL PERFORMANCE OF ALL HIS SUPPLIERS AND
SUBCONTRACTORS AS WELL AS ALL ASSIGNED CONTRACTORS IN ORDER THAT
THE ENTIRE PROJECT BE COORDINATED AND SUPERVISED
9. ALL GYPSUM BOARD PARTITIONS AND FURRED WALLS SHALL HAVE CONTROL
JOINTS AT 30' -0" O.C. MAXIMUM.
10. ALL WOOD STUD AND /OR WOOD BLOCKING TO BE FIRE RETARDANT
TREATED TO MEET RATINGS IF REQUIRED BY LOCAL OR STATE CODES.
11. ALL INTERIOR PARTITIONS TO BE FABRICATED OF METAL STUDS
SPACED AT 16" O.C. AND 518" GYPSUM BOARD, FIRE CODE "C" UNLESS
OTHERWISE NOTED.
12. GENERAL CONTRACTOR TO TURN OVER THE PROJECT IN COMPLETE
OPERATING CONDITION IRRESPECTIVE OF WHETHER THE DRAWINGS AND
REFERENCE SHEETS COVER EVERY INDIVIDUAL ITEM IN MINUTE DETAILS.
13. ANY COSTS INCURED BECAUSE OF CHANGES MADE BY THE GENERAL
CONTRACTOR WITHOUT PRIOR WRITTEN APPROVAL FROM THE
ARCHITECT'S OFFICE OR HSBC, WILL BE THE SOLE RESPONSIBILITY
OF THE GENERAL CONTRACTOR.
14. THE INTERNATIONAL ACCESSIBILITY SYMBOL IS TO BE PLACED ON
THE ENTRY DOOR OR ON THE GLASS ADJACENT TO THE LATCH SIDE
OF THE DOOR. THE SYMBOL SHALL BE APPROXIMATLY 6" SQUARE.
1 1 GENAERAL NOTES
No.
DOOR SIZE
REMARKS
DOOR
MAT.
JAMB
HEAD
REMARKS
101
_
ENTRY DOOR
1 FLOOR STOP
SIM TO
A
ANOD
ALUM.
11 PR. HINGES 1250
PROVIDED BY LANDLORD
102
3' -0'x6'- 8'x1314'
C
F.P.S.C-
7/A -1
SIM TO
7A-1
103
3' -0'x6'- 8'x1314'
-_
C
F.P.S.C.
71A -1
SIM TO
7 /A -1
144
Y -0 8'x1314'
B
F.P.S.0
7/A -1
_
SIM TO
7iA -1
105
EXISTING
EXIST.
-
-
-
106
EXISTING
EXIST.
-
_
_
PROVIDE PANIC RELEASE
DEVICE
[ DEVICE
107
EXISTING
EXIST.
-
_
_
PROVIDE PANIC RELEASE
4. NO THLA%f8 LATCHES OR KEYED CYLINDER DEAD BOLTS ALLOWED ON ANY DOORS UNLESS OPERATED BY A SNG..E ACTION WITH LEVER
5, MANUALLY - OPERATED EDGE OR SURFACEA40UNTED FLUSH BOLTS AND SURFACE BOLTS OR ANY TYPE OF DEVICE THAT MAY BE USED TO CLOSE
OR RESTRAIN THE DOOR OTHER THAN THE OPERATION OF THE LOCKING DEVICE SHALL NOT BE USED AND ARE PROHWED. 2001 CBC 1003,
6. EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL EFFORT-
NOTE: DOORS TO BE STANDARD
6'4' WITH METAL FRAMES
CL
NEW DOOR
EXISTING DOOR
EXISTING DOOR
TO REMAIN
TO BE REMOVED
q DOOR SCHEDULE
Q
L
W"
18' SIDELITE
1/4' TEMP. GL. 1/4' TEMPERED
ALUM. FRAME F.P.S.C. F.P.S.C. GLASS
G.C. TO INSTALL
MAIL SLOT ON
HINGE SIDE
A b B C�
6 '
1. F.P.S.C. =FLUSH PANEL SOLID CORE. ALL DOORS TO HAVE METAL FRAME
5 DOOR TYPES
ONE LAYER 5/8' TYPE 7C GYPSUM
WALL BOARD APPLIED AT RIGHT ANGLES
OR PARALLEL TO EACH SIDE OF 3-5x8'
METAL STUDS 16' O/C WITH 1' TYPE
'S' DRYWALL SCREWS 8' 0 C TO VERTICAL
EDGES & TOP & BOTTOM RUNNERS
B 12' O/C TO INTERMEDIATE STUDS
STAGGER ALL VERTICAL. b HORIZONTAL
JOINTS 24' O/C EACH SIDE TO THE BOTTOM
OF CEILING.
�weuj Tp
3-518' METAL STUDS 20 GAUGE STEEL
3 I NON -RATED PARTITION
SCALE.- 1J8"=l'-(r
518' GYP. BD. H.M FRAME ANCHOR PAINT P2 3-50 METAL STUDS
PER MANUFACTURERS 20 GAUGE STEEL
SPECS.
I j L J
I I I
I I
i
I
I I
I I I
1
SILENCERS (3) MIN. DOOR ---� HINGE WOOD
BLOCKING
7 METAL JAMB DETAIL (TYP.)
l
o t� ,
i
) M!; 7
DIMENSION PLAN
+- e._. a.�.r -�..__ ��- � ... w_ � -�.�� ... r. :-_ - ,.- .�..��- �. -rte. +ter .�- �. ��.. _.���__. _.._ _� -� .. � _.,,.. � �.- a._ _ �.. � -..�. ��.. -.� '�� ...a..�._� � w . � ��.. _ _..rr..r .�.- "...w A.. �-�� -.+ �� `�•�i .�.- r'.�• �- ��_
SYMBOL
DESCRIPTION
REMARKS
EXISTING PARTITION TO REMAIN
11 PR. BUTTS 88 1279
6/8' GYP BD ON 3-518' METAL STUDS @
16' O.C_ TO BOTTOM OF SUSPENDED
CEILING.
--- ------
EXISTING PARTITION TO BE REMOVED
NOTE. CONTRACTOR TO VERIFY ALL DIMENSIONS IN FIELD.
2 IPARTITION SCHEDULE
GROUP NO.
DESCRIPTION
REMARKS
11 PR. BUTTS 88 1279
1
1 PASSAGE SET 93968 SERIES F10CSV SATIN CHROME
SEE NOTE 2
CLOSING
1 FLOOR STOP
11 PR. HINGES 1250
2
1 PRIVACY SET 33975 SERIES F40CSV SATIN CHROME 1 FLOOR
TOILET
STOP
1 DOOR SKIN
3
11 PR. HINGES COMMERCIAL GRADE SATIN CHROME 1
LOUNGE
PASSAGE SET 93968 SERIES F10CSV SATIN CHROME 1
FLOOR STOP
4
HARDWARE TO MATCH EXISTING (BUILDING STANDARD). VERIFY W1
REAR ENTRY
LANDLORD AND CONFIRM W/ BENEFICIAL PROPERTY MANAGER
5
1 CRL MAIL SLOT MS125A HARDWARE TO MATCH EXISTING
FRONT ENTRY
(BUILDING STANDARD). VERIFY W/ LANDLORD AND CONFIRM W/
BENEFICIAL PROPERTY MANAGER.
HARDWARE NOTES:
1, FINOES SHALL BE CHROME OR POL&U CHROME
2. G.C. TO VERIFY HARDWARE IS IN COtiPLANCE WITH ADA.
3. EXISTING HARDWARE TO BE REPLACED AS REQURED.
4. NO THLA%f8 LATCHES OR KEYED CYLINDER DEAD BOLTS ALLOWED ON ANY DOORS UNLESS OPERATED BY A SNG..E ACTION WITH LEVER
5, MANUALLY - OPERATED EDGE OR SURFACEA40UNTED FLUSH BOLTS AND SURFACE BOLTS OR ANY TYPE OF DEVICE THAT MAY BE USED TO CLOSE
OR RESTRAIN THE DOOR OTHER THAN THE OPERATION OF THE LOCKING DEVICE SHALL NOT BE USED AND ARE PROHWED. 2001 CBC 1003,
6. EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL EFFORT-
6 HARDWARE SCHEDULE
CAI L%d#n"_.:t
L
W •l�r
UO
z
Z
LL 0
Go
J
—
LJ Y
Zm�
L1J Lc) �
F--
.o
U°
C/7 a
�o
W .p � "
a a. •- o
it O r�
.0 0
= PA6
M
Q L u 0
�� =a
0 0 6 6
Da. = 2 .CI a
2 �N
FC b .�i f
v
u
F Z I
I�;� il�I ' Iif
•� 71 I
a_ l
W
J
W
2
U
Z
Q
J
a
Z
0
C!1 J U)
z —
LU Q
,�. LLJ
00
Rev,,iam
0
r,
M?Ltt.,TiC
I
Jc
r • -6 4 sw ::Mp. ' 1I'- 0— k..r S.
f«► air aw= agk1'MCFS Y - -OWL • %A
a 're sTftjGTLvRcs 4m et at
9�AhC!- s
slaw BI► C>A�1: 9s
05�2208
AA
S�
5�
.� A4
H.V.A.C. NOTES ALL HN.A.C. EQUIPME E TO BE REUSED
1. HEATING, VENTILATING AND AIR CONDITIONING CONTRACTOR SHALL
FURNISH AND INSTALL ALL DUCTWORK, DUCTWORK INSTALLATION,
REGISTERS, GRILLES, DIFFUSERS AND TERMINAL BOXES
2 HEATING, VENTILATING AND AIR CONDITIONING
CONTRACTORS SHALL FURNISH ALL EQUIPMENT
TEMPERATURE CONTROL COMPONENTS AND
ANY SPECIAL MOUNTING OR SUPPORT
PACKAGE.
3 HEATING, VENTILATING AND AIR CONDITIONING
CONTRACTORS SHALL INSTALL ALL H.V.A.C., EQUIPMENT.
4. ALL WORK TO COMPLY TO LOCAL, MUNICIPAL AND NATIONAL
HEATING AND VENTILATION CODES.
S. CONTRACTOR TO COORDINATE ALL WORK WITH THE
RESPECTIVE TRADES AND VERIFY LOCATIONS FROM THE
ARCHITECTURAL DRAWINGS AND FIELD MEASUREMENTS
AND SUPPLIER SHOP DRAWINGS,
7 OBTAIN AND PAY ALL PERMIT AND INSPECTION FEES
AS REQUIRED FOR THIS PORTION OF THE WORK
6 LAYOUT IS DIAGRAMMATIC AND CONTRACTOR SHALL
INSTALL EQUIPMENT AND DUCTWORK TO MEET THE
FIELD CONDITIONS AND PROVIDE SHOP DRAWINGS
AS MAY BE REQUIRED FOR THE WORK
9 ALL DUCTWORK CONSTRUCTION SHALL CONFORM
TO LOCAL CODES AS WELL AS A.S.H.R.A.E AND
S M.A C.N.A. CONSTRUCTION STANDARDS FOR
LOW VELOCITY DUCTWORK CONSTRUCTION AND
NFPA 190-A.
10. BRANCH TAKE -OFFS SHALL HAVE SPUTTER DAMPERS
OR MANUAL DAMPERS FOR ALL SUPPLY OR RETURN
AIR DUCT BRANCHES. ALL MAIN BRANCHES SHALL
HAVE MANUAL DAMPERS.
11. UPON COMPLETION OF INSTALLATION OF VENTILATION
DUCTS, CLEAN ENTIRE SYSTEM OF RUBBISH, PLASTER,
DIRT, ETC. BEFORE INSTALLING GRILLES OR DIFFUSERS
12. AFTER ADJUSTMENTS HAVE BEEN MADE TO THE
HEATING, VENTILATING AND AIR CONDITIONING SYSTEM,
THE HEATING, VENTILATING AND AIR CONDITIONING
CONTRACTOR SHAH BALANCE THE AIR DISTRIBUTION
SYSTEM, SUBMIT THREE SETS OF DATA OF THE TEST
AND BALANCE TO THE OWNER FOR APPROVAL.
13. ALL NEW DUCTWORK SHALL BE LINED WITH 1' FIBERGLASS
ACOUSTIC LINING, CONSTRUCTED PER SMACNA STANDARDS,
STANDARDS, MAXIMUM S-T FLEX DUCTWORK ALLOWED.
14. PROVIDE FACTOR FABRICATED TURNING VANES IN ALL
SQUARE TURN ELBOWS.
6. CONTRACTOR TO VISIT THE SITE TO DETERMINE THE
FULL EXTENT OF THE WORK AND FACILITY
LOCATIONS AND VERIFY WITH GOVERNING BODIES.
� GENERAL NOTES
RECEPTION
i
15. PROVIDE FLEXIBLE DUCT CONNECTORS BETWEEN DUCTS,
FANS AND AIR HANDLING UNITS AND ALSO IN DUCTS
CROSSING BUILDING EXPANSION JOINTS.
16 NO GRILLES WILL BE INSTALLED IN ANY DOOR NOR WILL
UNDERCUTTING OF ANY DOOR BE PERMITTED.
17. PROVIDE MANUAL DAMPERS AT SUPPLY GRILLES.
18. PROVIDE MECHANICAL VENTILATION IN ALL ROOMS
CAPABLE OF SUPPLYING A MINIMUM OF 15 CUBIC FEET PER
MINUTE OF OUTSIDE AIR.
19. G.C. TO COORDINATE WITH SPRINKLER CONTRACTOR ON
ANY ADJUSTMENTS TO EXISTING SPRINKLER SYSTEM. (IF
APPUCABLE)
VERIFY ALL EXISTING
CONDITIONS AND
AS NEEDED
4l P... 4e�"
3'�be az4d�c�
�
1�� -2?d
V �fv
MAW �
REFLECTED CHUNG PLAN
I se " �4r
•
40
SYMBOL
DESCRIPTION
SYMBOL DESCRIPTION
I
ca
EXISTING 7x4'
PRISMATIC 4 BULB
FLUORESCENT FIXTURE
I SINGLE POLE SWITCH
( +4' -0'AFF}
r HONEYWELL'MAGICSTAT' PROGRAMMABLE THERMOSTAT
*C T 3200A 1001 OR EQUAL.
�-�
2'x4' PRISMATIC 4 BULB FLUORESCENT
FIXTURE (1) TUBE OPERATING AS A
NIGHT LIGHT.
I - COMBINATION EXIT SIGN 3
EMERGENCY LIGHT
COMBINATION LIGHT!
q1T
0
Z T-
EXHAUST FAN (TOILET ROOM)
z
TYPICAL SUPPLY DIFFUSER
WITH MANUEL DAMPER
i
u
2 - �
2 - RATED FIRE EXTINGUISHER
W
TYPICAL RETURN/
L i..
co
co
EXHAUST GRILLE
a
co
w
J
LL
W—
Y
w
j
Z
W
Z
m
3:
L
2 FIXTURE LEGEND
r
L7
th
co
CA)
EIIIIIIIIIIIII
d
C
d
m
00
o
c " 40
LL o.
S �o
W ���
cle
po0•
toy
a�
Z »IW.
LAJ . O
0
=
00 46
CL
a
2
a -
I
FZ1
Revi
O sims
O
O
O
O
1
Pr
R1RC . T
i
i
F M 41C1■1.EX& Sma :31P w - 4iL_ , k_. S
W-!:t-L +'C'46 MC - - - -ow. • I"
qp a re sTft.1Gvwws 4K: RJt 74wt
OP4*0- !
Gas
sore �t
AS 110111D +
ilk
05�2208
amp*
Is
ca
Z
W
UO
q1T
0
Z T-
z
Q
u
W
L i..
co
co
a
co
w
J
LL
W—
Y
w
j
Z
W
Z
m
3:
L
W
�
=
W
w
im
qqr
H
W
j
00
o
c " 40
LL o.
S �o
W ���
cle
po0•
toy
a�
Z »IW.
LAJ . O
0
=
00 46
CL
a
2
a -
I
FZ1
Revi
O sims
O
O
O
O
1
Pr
R1RC . T
i
i
F M 41C1■1.EX& Sma :31P w - 4iL_ , k_. S
W-!:t-L +'C'46 MC - - - -ow. • I"
qp a re sTft.1Gvwws 4K: RJt 74wt
OP4*0- !
Gas
sore �t
AS 110111D +
ilk
05�2208
amp*
Is
1 ALL FLOOR SURFACES MUST BE SMOOTH AND LEVEL, FREE OF DIRT, WAX AND OLD ADHESIVES PATCH AND FILL CRACKS AND DEPRESSIONS WITH A LATEX BASED FLASHING COMPOUND SUCH AS LEV -L- LASTIC OR
SIMILAR FOLLOW WITH LEES EVERSEAL FLOORING SEALER LEAVING NO G IN THE INSTALLATION CARPET SHOULD BE CONDITIONED ON SITE AT A MINIMUM OF 65 DEGREES F FOR 24 HOURS BEFORE AND 48 HOURS
AFTER INSTALLATION VERIFY MATCH BETWEEN DYE LOTS INSTALL CARPET IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS AND THE CARPET AND RUG INSTITUTE'S INSTALLATION STANDARD, CRI 104
MAKE CUTS STRAIGHT, TRUE AND UNFRAYED CUT CARPET FOR TIGHT. NEAT FIT AGAINST WALLS, COLUMNS, PROJECTIONS. AND EDGE STRIPS WITHOUT GAPS REMOVE EXCESS ADHESIVE FROM FLOOR. BASE, DOORS.
AND WALLS WITHOUT DAMAGE CLEAN AND VACUUM CARPET SURFACES PROTECT TRAFFIC FROM CARPET AREAS FOR 24 HOURS AFTER INSTALLATION CARPET SHALL BE TILE SIZE WITH REGULAR BACKING NONSTICK
CARPET SHALL NOT BE USED
2 ALL. WALL SURFACES WILL BE SMOOTH AND DRY WITH NO IMPERFECT IONS BUMPS, ROUGH WALL JOINTS AND OTHER DEBRIS ON THE WALL SURFACE WILL NOT BE ACCEPTED. ALL WALLS WILL BE PRIMED WITH SEALER
PRIOR TO WALLCOVERING OR PAINTING
3 ALL GLUE TO BE REMOVED FROM EXPOSED SURFACE OF WALLCOVERING AFTER INSTALLATION STRAIGHT AND UNDETECTABLE SEAMS ARE REQUIRED, THE DOUBLE CUTTING METHOD OF INSTALLATION IS
RECOMMENDED CUTTING THROUGH THE DRYWALL WILL NOT BE ACCEPTED AND WILL RESULT IN THE CONTRACTOR REMOVING THE OLD WALLCOVERING, REPAIRING THE WALLS AND BUYING NEW WALLCOVERING AT
THE CONTRACTOR'S EXPENSE
4 PRIME WALLS AND TRIM TO BE PAINTED WITH ONE COAT OF ALKYD PRIMER SEALER FOLLOWED BY TWO COATS OF LATEX PAINT PER SPECS. BEJAMIN MOORE OR SHERWIN WILLIAMS-
GENERAL NOTES
A PLASTIC LAMINATE STORAGE CABINET LOCATED ABOVE TOILET SHALL BE MILLS PRIDE WALL BRIDGE CABINET MODEL #OJ2428CC WITH CLASSIC FINISH DOORS.
B PROVIDE "BLANK' COVER PLATE(S) FOR EACH EXISTING ELECTRICAL AND PHONEJDATA OUTLET NOT UTILIZED PER NEW CONSTRUCTION.
1 1 GENERAL NOTES
SCALE-
LOCATION
FLOOR
WAILS
CEILING
COMMENTS
ARCH.
NO
ROOM
NAME
MATERIAL
L
FINISH
BASE
MATERIAL
FINISH
MATERIAL
FINISH
HEIGHT
VCT -1
#51803 PEARL WHITE
232 S.F.
USE SABLE BROWN -
LEES - FACILITIES
N/A
C -1
#301 HEMLOCK
158 S.Y.
B-1
I.F.
CERAMIC TILE
101
WAITING
CONC
CT -
B1
GYP. ! .
WC1
ACT1
-
FISSURED
10'-0"
SEE HB1
102
RECEPTION
KOROSEAL - ARCADIA
Cl
ARMSTRONG-STANDARD
GLASS/
VERIFY WITH PROPERTY MANAGER IF EXISTING FLOOR COVERAGE TO REMAIN
VINYL COMPOSITION
SEE H81
103
CLOSING 1
GLASS/
GYP. BD,
I
LINEN
'
SEE HB1
104
_.
CLOSING 2
ARMSTRONG STANDARD SHEET
---�
GYP.
GYP. BD.
NIA
VINYL/LINOLEUM G.0 TO
_
SEE HB1
105
MEETING
I
GLASS/
GYP, BD
JOHNSONITE #80 FAWN 1i8"
`
T
SEE HB1
106
SALES
ROPPE #140 FAWN 1B'
VINYL COVE BASE, 4' H
GLASS/
GYP. B0.
TS1
ROPPE #177 CARPET TO
HB1
TRANSITION STRIP
NIA
TILE ADAPTOR COLOR:
#140 FAWN
CARPET TO TILE ADAPTOR
COLOR: #80 FAWN
LEES - FACILITIES #224
SEE NOTE #1
C1
(ASTM E 648 )CLASS 1
INTERFACE CARPET
HOUSEHOLD
107
MANAGER
FLOOR SEALER:
CARPET
(ASTM E .662) 450
SYMMETRY #4295
GLASS/
GYP. BD.
INTERNATIONAL,.
I
LEES- EVERSEAL
(ASTM E•84)
DSI - KOROSEAL
SEE HB1
108
O
LUNGE
VCT1
(TUNNEL TEST)
GYP.BD.
P - 1
SEE NOTES #2 AND #3
VINYL WALLCOVERING
FLAME SPREAD: 10
SYCAMORE 54" w/ NO
1. ALL PERMANENT ROOMS WILL REQUIRE ADA COMPLIANT SIGNAGE. ROOM DESIGNATIONS TO BE PROVIDED BY THE BENEFICIAL GENERAL
CONTRACTOR.
2 ROOM FINISH SCHEDULE
I SCALE-
cp
i
FINISHED
FLOOR
4" VINYL SEE SHT. A-3
BASE
6 I ELEVATION @CLOSING ROOM
SCANL_c
- I -
2.''X 3v
L Aoil
- ap
-f Q _ E� �m 5<
O •�
F -"
RECEPTION
,02
At
WAITING
1 o,
CLOSING I
F
CLOSING 2
KITCHEN ELEVATION FM RE / F I N ISN 7 8
sc^l
^^"r►'�"- +�.- ...�- .�-.--- '.�..r�-. sue-.- --�" .► .. -�. .... -- ..fw. -..,. ,. -�.�- �. �. �...- ..�...- -+•• -v +�.... --�_. _ .•-'�- _ ..- _ - �.
DIRECT GLUE DOWN CARPET
CONTRACTOR TO ADJUST FLOOR LEVEL
AS REQUIRED TO PROVIDE FLUSH
TRANSITION
RUBBER ADAPTER STRIP
(JOHNSONITE #CTA-40-H)
VCTISOLID TILE
3 I INTERIOR THRESHOLD
CODE
DESCRIPTION
QUANTITY
AMERICAN OLEAN- SELECT
CT -1
PORCELAIN TILE - #SL
62 S.F.
DESCRIPTION
*ALMOND'. 17028 OR 18608"
PROVIDED BY:
INSTALLED BY:
ARMSTRONG-STANDARD EXCELON,
VCT -1
#51803 PEARL WHITE
232 S.F.
USE SABLE BROWN -
LEES - FACILITIES
N/A
C -1
#301 HEMLOCK
158 S.Y.
B-1
ROPPE #140 FAWN 118"
CERAMIC TILE
VINYL
VINYL COVE BASE, 4" H
352 L.F.
BASE
CONTRACTOR
ALTERNATE HYDROMENT #627 -327
TS-1
MERCER #152 CARPET TO TILE
19 L.F.
TILE A155-009 "GOLD" 12"x12'.
ADAPTOR #201 BROWN
WC -1
KOROSEAL - ARCADIA
317 S.Y.
ARMSTRONG-STANDARD
A421 -04 SYCAMORE
NOTE: VINYL COVE BASE INCLUDES STOREFRONT, DEDUCT IF NOT NEEDED
VERIFY WITH PROPERTY MANAGER IF EXISTING FLOOR COVERAGE TO REMAIN
FLOORINGMALL FINISH SCHEDULE
MEMO No
MENOMINEE
MENNEEN
MEN MEN
OEM ON
mommosom
Emommom
moommommom
0
5 FINISH SCHEDULE
'I SCALE.
1
1
1
1
1
1
w �
1 ac
1
1
1
1
PROVIDE AND INSTALL A 2-A RATED FIRE EXT. (MIN.) IN
A COASpMCUOUS LOCATION N ACCORDANCE YMTFH
STATE AND LOCAL CODES,
r 1
i T 3n7r 30172•
s
1
C-1
M 3C'xTI 3'tcAr 1'
j ...go—
f � f
I
c
1 ' i 3�1rT1" 30'x?
v I �
24'��a48'
o --
a
1816
I�
r .
+r.
VCT -1
I �
AlL AIL
[71 Ln ri
i?
MANAGER
107
> LOUNGE _
108 r-
SALES
� II - I1
L
L
J
L J_ L w w
PIE -`%` `n
r � �
0 6
cn
W
.j
0
0
W
cr)
Z
U
w
W Z
U Q
r J
W Q-
z _
LL c T_
..Ji:)co z
Q J LL
W U)
LL Y g
W
Z
W U-) Y X W
m � F_ lL O
.o
o
• gyp
'�► , o
W �
tol:
Q� -°i�o
Q u, ; 0
t_a
o046
0
a
Z_cm ag
V Q ge �.
' i;•'�'�;i� liii
O
O
�I 0
I A2GIi: + ALT
s-
i
V ^ y'f
'7•
yy 7 � • j - �7T�:�
•i L Its.
J Y .Pw, a Y
VC S*R.CTums aye 1V`
>Ra■w �! Cods IN
SJc �
Sale 011lae
05�2208
�►s Iwa� IIIi,�-�
J� Aa
smw f.
A�3
i
s
FLAME SPD./
CODE /USE
MOKE INDE
DESCRIPTION
ALTERNATE:
PROVIDED BY:
INSTALLED BY:
COMMENTS
AMERICAN OLEAN-
HOME DEPOT - DAL TILE - DEMETRA PORCELAIN
USE SABLE BROWN -
CT1
N/A
SELECT PORCELAIN TILE
TILE P052, A188- 398'PARADISO SAND 13'x13'
GENERAL.
GENERAL
POLYBLEND #95 GROUT
CERAMIC TILE
- #SL51 "ALMOND' 12'x12`
HOME DEPOT - DAL TILE - TRAVERSA GLAZED
CONTRACTOR
CONTRACTOR
ALTERNATE HYDROMENT #627 -327
OR 16'x1' _
TILE A155-009 "GOLD" 12"x12'.
I
FLASH WALNUT GROUT
VCT1
ARMSTRONG-STANDARD
ARMSTRONG- STANDARD
VINYL COMPOSITION
FLAMMABILITY 1
EXCELON, #51803 PEARL.
EXCELON, #51810 WASHED
TILE
WHITE
LINEN
ARMSTRONG STANDARD SHEET
---�
VC1
NIA
VINYL/LINOLEUM G.0 TO
SHEET VINYL
CORRDINATE WITH HSBC
PROPERTY MANAGER ON BRAND.
JOHNSONITE #80 FAWN 1i8"
I
4 " HIGH
BI
VINYL BASE
FLAMMASILITY:1
ROPPE #140 FAWN 1B'
VINYL COVE BASE, 4' H
VINYL COVE BASE 4" N
JOHNSONITE #CTA -XX -A
TS1
ROPPE #177 CARPET TO
TRANSITION STRIP
NIA
TILE ADAPTOR COLOR:
#140 FAWN
CARPET TO TILE ADAPTOR
COLOR: #80 FAWN
LEES - FACILITIES #224
SEE NOTE #1
C1
(ASTM E 648 )CLASS 1
INTERFACE CARPET
HOUSEHOLD
FLOOR SEALER:
CARPET
(ASTM E .662) 450
SYMMETRY #4295
ETCHING BROWN
INTERNATIONAL,.
I
LEES- EVERSEAL
(ASTM E•84)
DSI - KOROSEAL
DSI - KOROSEAL
�—
WC1
(TUNNEL TEST)
ARCADIA #A421-04
VIEWPOINT #V221 -33
SEE NOTES #2 AND #3
VINYL WALLCOVERING
FLAME SPREAD: 10
SYCAMORE 54" w/ NO
DRIFTWOOD 54" w/ NO
SMOKE INDEX: 5
REPEAT
REPEAT
ARMSTRONG FISSURED
GENERAL.
CEILING GRID - ARMSTRONG (OR
ACT1
(ASTM E 1264)
MIN BOARD 2'X4' WHITE
CONTRACTOR
EQUAL) 15116 WHITE FOR 2514'
ACOUSTICAL CEILING
ACOUSTICAL CELL. TILES 3"R-1 1
TILE
CLASS A
PAPERFACED BATT INSULATION
(7X4' LAY -IN) ABOVE CEILING
TILES
BENJAMIN MOORE
SHERWIN WILLIAMS SW
r
READY MIX - ATRIUM
1910 TENNIS WHITE
WALLS IN BREAK/STGfTOILET
P1
NIA
WHITE REGAL AQUA
PRO MAR 200 LATEX
ROOMS SEE NOTES #2 AND #4
PAINT
VELVET LATEX
EGGSHELL ENAMEL
EGGSHELL ENAMEL
BENJAMIN MOORE
SHERWIN WN-LIAMS
#1018
#1086 SAND STORM
DOORS AND FRAMES
P2
NIA
REGAL AQUA GLO, LATEX
PRO MAR 200
THROUGHOUT SEE
PAINT
SEMI -GLOSS ENAMEL
SEMI -GLOSS ENAMEL
NOTES #2 AND #4
HB1
NIA
VISTA -1" METAL #006
'RAW UMBER" OR #205
HOUSEHOLD
PROVIDE Q STOREFRONT
MINI BLINDS
WHITE SATIN
INTERNATIONAL
VENDOR
SEE NOTE 5
(ASTM E-84)
N EVAMAR #S-7-24T
PL1
(TUNNEL TEST)
WILSONART #D 354-6 DESIGNER
CHALK WHITE MATTE
GENERAL
GENERAL
COUNTER TOP FOR BREAK
PLASTIC LAMINATE
FLAME SPREAD: 55
WHITF MATTE FINISH
FINISH
CONTRACTOR
CONTRACTOR
ROOM CABINETS
SMOKE INDEX: 40
FRP
(ASTM E-84)
MARLITE #5-100
FORMICA #934
4'-0" TALL AROUND
FIBER REINFORCED
CLASS III/ C
WHITE SLATE
PEARL-
BATHROOM WALLS
POLYESTER PANELS
SEE ROOM FINISH
5 FINISH SCHEDULE
'I SCALE.
1
1
1
1
1
1
w �
1 ac
1
1
1
1
PROVIDE AND INSTALL A 2-A RATED FIRE EXT. (MIN.) IN
A COASpMCUOUS LOCATION N ACCORDANCE YMTFH
STATE AND LOCAL CODES,
r 1
i T 3n7r 30172•
s
1
C-1
M 3C'xTI 3'tcAr 1'
j ...go—
f � f
I
c
1 ' i 3�1rT1" 30'x?
v I �
24'��a48'
o --
a
1816
I�
r .
+r.
VCT -1
I �
AlL AIL
[71 Ln ri
i?
MANAGER
107
> LOUNGE _
108 r-
SALES
� II - I1
L
L
J
L J_ L w w
PIE -`%` `n
r � �
0 6
cn
W
.j
0
0
W
cr)
Z
U
w
W Z
U Q
r J
W Q-
z _
LL c T_
..Ji:)co z
Q J LL
W U)
LL Y g
W
Z
W U-) Y X W
m � F_ lL O
.o
o
• gyp
'�► , o
W �
tol:
Q� -°i�o
Q u, ; 0
t_a
o046
0
a
Z_cm ag
V Q ge �.
' i;•'�'�;i� liii
O
O
�I 0
I A2GIi: + ALT
s-
i
V ^ y'f
'7•
yy 7 � • j - �7T�:�
•i L Its.
J Y .Pw, a Y
VC S*R.CTums aye 1V`
>Ra■w �! Cods IN
SJc �
Sale 011lae
05�2208
�►s Iwa� IIIi,�-�
J� Aa
smw f.
A�3
i
s
1 VERIF Y EXISTING CONDITIONS AND LOCATIONS INFIELD PRIOR TO
SUBMIT T ING PROPOSAL FAILURE TO 00 SO SHALL NOT REL IEVE THIS
CONTRACTOR FROM PERFORMING THE WORK REQUIRED UNDER THIS
CONTRACT
2 MAKE NECESSARY MODIFICATIONS AND ADJUSTMENTS TO ALL ELECTRICAL ITEMS
AND EQUIPMENT. BOTH NEW AND EXISTING, AS MAY BE REQUIRED BY THESE
AL I k 4A I IONS AND ADDITIONS
3 THIS CONTRACTOR SHALL FURNISH AND INSTALL ALL MATERIAL INDICATED ON DRAWINGS
AND AS RkQUIkkU
1 0 PROVIDE A COMPLETE AND SAT ISFACTORY OPERAI ING
INSTALLATION INSTALLATION SHALL BE LEFT IN OPERATION
4 ALL MATERIALS SHALL_ BE NEW AND OF STANDARD QUALITY, NO REJECTS ALL
MATERIALS FOR WHICH AN UNDERWRITERS LABORATORIES STANDARD EXISTS
SHALL BEAR A U L LABEL. PROTEC I ALL E(AJIPMENT AND WORK FROM DRAINAGE
DUE TO My CAUSE.
5 DUPLEX RECEPTACLES SHALL BE HUBBELL #5242 OR APPROVED, OR EQUAL.
SINGLE POLE SWITCHES SHALL BE HUBBELL #1201 OR APPROVED EQUAL COVER
P LATES SHALL BE PLASTIC, IVORY OR BROWN AS SELECTED BY PROPERTY
MANAGER. HUBBELL #98000 OR 999000 SERIES OR APPROVED EQUAL. AND SHALL
BE INSTALLED 1S" A.F.F.
6. IN GENERAL, FLUORESCENT LIGHTING CIRCUITS SHALL BE 20 AMP #12 TW WIRE
MINIMUM, INCANDESCENT LIGHTING CIRCUITS SHALL BE 20 AMP. #12 TW WIRE
K41KIMUM AND RECEPTACLE CIRCUITS SHALL BE 20 AMP, #12 TW WIRE MINIMUM
7 ALL WIRE SIZES INDICATED ARE FOR COPPER CONDUCTORS ALL WIRE SHALL BE
COPPER. ALL WIRING SHALL BE INSTALLED IN E M.T. CONDUIT FLEXIBLE METAL
CONDUIT MAYBE USED FOR CONNECTIONS TO FIXTURES LOCATED IN
ACCESSIBLE TILE CEILINGS.
8- T H!S CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PLAN EXAMINATION FEES,
PERMITS, AND JOB INSPECTION FEES REQUIRED FOR THIS WORK.
1 9 ALL WORK SHALL BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE LAWS,
ORDINANCES, REGULATIONS, AND ELECTRICAL CODES
10. THIS CONTRACTOR SHALL COORDINATE HIS WORK WITH ALL ARCHITECTURAL,
STRUCTURAL, AND MECHANICAL FEATURES OF THE BUILDING, CONSULT
ARCHITECTURAL, STRUCTURAL AND MECHANICAL PLANS. ADJUST WORK TO FIT
ACTUAL JOB CONDITIONS. COOPERATE WITH OTHER CONTRACTORS.
11. THIS CONTRACTOR SHALL REMOVE ALL RUBBISH, DEBRIS, ETC. CAUSED BY HIG
WORK AS FAST AS IT ACCUMULATES.
12. THIS CONTRACTOR SHALL GUARANTEE ALL OF HIS WORT( FOR ONE YEAR AFTER DATE OF
WRITTEN ACCEPTANCE BY OWNER AGAkST ALL DEFECTS OF MATERIAL, EQUIPMENT AND
WOR MANSHIP. ALL SUCH DEFECTS APPEARING WITHIN THE GUARANTEE PERIOD SHALL
BE PROMPTLY REMEDIED WITHOUT FURTHER COST TO THE OWNER. ENTIRE
INSTALLATION SHALL BE GUARANTEED TO OPERATE SATISFACTORILY.
13. EXTRA WORK MUST BE APPROVED IN WRITING BY THE PROPERTY MANAGER. WITHOUT
THE WRITTEN APPROVAL, NO EXTRA PAYMENT WILL BE MADE.
14. THIS CONTRACTOR SHALL DO ALL CUTTING AND PATCHING REQUIRED FOR HIS WORT(
15. ALL DUPLEX AND QUAD RECEPTACLES SHALL BE LOCATED AT 15 ABOVE FINISHED
FLOOR, UNLESS NOTED OTHERWISE.
l�R/FY L OCA 7/OA( OF
J BOX FOR S/GNAGE
I - A -25=
� I
111
A -23- /
; -2.
-AAA"
A -2, 4
t
1
i
i \ y
�.
. ' • -ti
' A -5
E I A-12 + rA - 5> >
- -5,7,9
t_
_A -24 /.
i PANEL A - f
3 '
I ! A- 14,16.18
T
i
A-- 14,
. , f
I
t 1
I A - �, • - _ _-
I
I � `- fi t--. • '
I =
1 I-
ri
t
OF
I T
ELECTRICAL PLAN
16 AT DATA CABINET, ALL DUPLEX AND QUAD RECEPTACLES SHALT. BE LOCATED AT 44
ABOVE FINISHED FLOOR EACH ON THEIR OWN DEDICATED CIRCUIT.
17 EXISTING LIGHT FIXT URES, RECEPTACLES, SWITCHES AND ELECTRICAL
PANELS SHALL BE REIAINEU AND REUSED AS POSSIBLE.
18 SIGN CIRCUIT - (NORMALLY REQUIRED) - THE ELECTRICAL SERVICE CONSISTING
OF ONE 20 AMP CIRCUIT IS TO BE PROVIDED FOR THE EXTERIOR SIGN IT WILL BE
SWITCHED BY A TIME CLOCK LOCATED ON THE WALL NEXT TO THE ELECTRICAL
PANEL- THE TIME CLOCK IS TO BE TOF:K MODEL 4110124 HOUR CLOCK OR
COMPARABLE SUPOLIED BY THE CONTRACTOR. THE CIRCUIT WILL TERMINATE IN
A JUNCTION BOX NOT FURTHER THAN 3' FROM WHERE THE SIGN IS TO BE
INSTALLED. THE SIGN WILL BE FURNISHED BY BENEFICIAL TO DETERMINE WHERE
THE SIGN IS TO 3E LOCATED
19. TELEPHONE AND DATA - PROVIDE A JUNCTION BOX LOCATED 15' ABOVE FINISHED
FLOOR TO JUST ABOVE THE CEILING AT EACH LOCATION WHERE DATA AND/OR PHONE
IS TO BE INSTALLED. NO JUNCTION BOX IS NEEDED WHERE THE WIRING WILL
TERMINATE IN THE DATA ROOM. USE 14' CONDUIT ONLY
20. CONDUIT SHOULD BE 3 4 - WITH JUNCTION INSTALLED AT A MINIMUM OF 15' A.F.F. AND A
PULL STRING. DATA DROPS WILL BE CAT 5 WIRE WITH TWO DATA AND TWO VOICE AT
EACH STATION.
21 ALL WORK SHALL COMPLY WITH THE CURRENT EDITION OF THE NATIONAL ELECTRICAL
CODE AND ALL LOCAL CODES -"OORDINATE EXACT CODE REQUIREMENTS AND LOCAL
AMENDMENTS WITH LOCAL INSPECTOR PRIOR TO ANY INSTALLATION.
22 ALL BRANCH CIRCUIT BREAKERS SHALL BE "PLUG-ON' TYPE RATED AT 20 AMPERE -1
POLE FOk 75 C WIRE, UNLESS NOTED.
23. ALL 20 AMP CIRCUIT BREAKERS USED AS SWITCHES SHALL BE ULSWD RATED & SHALL
BE MARKED "SWD'.
24. PROVIDE SPACES WITH MOUNTING HARDWARE FOR FUTURE BREAKER INSTALLATION
25. PANELS TO BE MANUFACTURED BY SQUARE')' (OR APPROVED EQUIVALENT), WITH
FLUSH LOCK AND KEYED ALIKE.
26. NO MORE THAN 3 WORKSTATIONS ON A CIRCUIT.
27. NIGHT LIGHT(s) TO BE "ON" 24 HOURS CONTINUOUSLY.
28. EXISTING RTU's AND DUCTWORK TO REMAIN, REROUTE NEW DIFFUSERS WITH FLEX
INTO EXISTING DUCTWORK
1 I ELECTRICAL NOTES
SCALIE
1 200, v.11 1, ` l r ... .L Y .. 2� /l� t .� '. ��• r ` l��T - I • , v ' •rJ Y ; ..
r , � 1. �\�'. .. -, Jr � .. I 1' ._.,.1 �. (. - _ � � I' � y _/•� .- —_— t `1• '� JE • y CF• T
r, j I I r I NOTES
I _ ! 1 FURNISH AND INSTALL LIGHTING CONTROL CONTACTORS, IN A HINGED NEMA t ENCLOSURE OF
^f � �t�l ; 1 • _I 1 i :' 1 ;, ' 1 ' 1 r 1 , } — - - . �,- • - -� -- - ADEQUATE SIZE, SURFACE MOUNTED NEXT TO ELECTRICAL PANEL CONTACTORS SHALL BE MULTI - POLE,
20 AMP RATED ELECTRICALLY HELD, MANUFAC f URED BY SQUARE -D OR APPROVED EQUAL PROVIDE
3 �, 1 ) / , c ��,• : , .,! . ; R.
TERMINAL STRIPS FOR All LINE AND LOAD CONDUCTORS IDENTIFY THE CIRCUIT NUMBER FOR EACH
4 CONDUCTOR USING WIRE LABELS AND PROVIDE A SCHEDULE INSIDE OF THE ENCLOSURE IDENTIFYING
1- , �; , THE LOAD 1 �� � 1 y EACH clRculT SERVES
' 1 T �1
2 ALL LIGHTING CONTACTORS TO HAVE A M!N OF IS.O U A I C INTERRUPTING RATING
54 fit• . `� �,
�. ,
';1 , ! 0 , H „ ', j �F . ' ` A ' L, . ;,; . • I • • ; •; N
120
- - - - -- l�: rt, -- -I r.. �, I I OU'�,•� 5 TVOR —
-f - -- __ ---- 1 -- _ - -- --: - - __- {�
1 - _ I - S ITS - ---�
00 v( ,'�< } 1�1.•GI LyE �' A1� : , ^ !( J; Breakers I
- - - - -- -- - _. - — -- _- - - - - - -- @ Panel I -
� F - - - - -� ;; � ' 1 1 _- TS1 P1
-- -- - --� � t -- S -- -� -- NEMA II
Sr :;r :�.I I I I "= '1 ► 5� j `= I Enclosure I I I
` c' 1 J SP n - -- I With Hinged Lockable I I 1-1
- - -. - - - -- - --- - ---�- - - ---: - -: ____ I Door - Recessed Mount
Size asRewimd - --- --�-�• 1
41 j
VERIFY EXISTING RTU. ADJUST BREAKER SIZE AND WIRE SIZE ACCORDING -
SIGN'
3 ELECTRICAL LEGEND
TO EXISTING CONDITIONS. 0 _ --� - - - - --
VERIFY EXISTING HWH. ADJUST BREAKER SIZE AND WIRE SIZE ACCORDING - - - — - - - -- - -
TO EXISTING CONDITIONS. P r. Cvr.' . _ 'c I 'fir :. 3 , _ _ - _ T'
METERING EQUIPMENT
,! #6 GROUND
IN 21/2"
CONDUIT
9 I
EXISTING
PANEL
'A'
i I
ONE LINE DIAGRAM
!
K,T�.rc.} �. p! 0 C
- -- ---r --
' _' L0. _ _ C o� 0! C C'
L0 -_ -- 2-
,
2 PANEL DIAGRAM
r r�
}
I
C
- 24 "x72" ROLLING 0
CABINET
4 C DATA CABINET &PHONE BOARD
Cam'
�,�. y N
C ' O
�� �� —w •- .�,•�. +�.... -.�-�. +��..�.- •.•+r- -s ,ter -. �.. - 'w + +� �+r �.�� � v+.�.�.�.�'. i'e"n'�.wvti��_ - -. _ ..- �... _ice �. �.rr���
�- 4'x4' PLYWOOD FOR
PHONE EQUIPMENT
MOUNTING
cc
4)
Q
O
J
W
W az
Uo 0
w
Z� J>
CID Uj
co
Q J00 Q W
m Q U °tS
LLw� � Z
Zm3 W C�
Y
CCC
m � H W J
. o
V°
40
a
=
a LU
ce 0 v 4; Co.
C?
=.00
z V...�
..
< 1. 0
mm i
O • •
a. Z00,
_()
=QC o atv
too q
No
d
1I +
•!III; :1.... , ....Il�il, I
0 0 #
�g
I
- ESE a_ a* -++; �
�iF : JUF� � :JaG�.�5iC1r. �IIC - f" _ ''f f• : _
vP a''�rC *C S' -Ikjc � me out 31wc
f 0
fir+ 91r C?Krllet 96
Saft Dm
05-2208
_r
E -1
H-V,
1 HEATING, VENTILATiNG AND AIR CONDITIONING CONTRACTOR SHALL
FURNISH AND INSTALL ALL DUCTWORK, DUCTWORK INSTALLATION,
REGISTERS, GRILLES DIFFUSERS AND TERMINAL BOXES
2 HEATING, VENTILATING AND AIR CONDITIONING
CONTRACTORS SHALL FURNISH ALL EQUIPMENT
TEMPERATURE CONTROL COMPONENTS AND
ANY SPECIAL MOUNTING OR SUPPORT
PACKAGE
3. HEATING, VENTILATING AND AIR CONDITIONING
CONTRACTORS SHALL INSTALL ALL H V A C . EQUIPMENT
4 ALL WORK TO COMPLY TO LOCAL, MUNICIPAL AND NATIONAL
HEATING AND VENTILATION CODES.
5. CONTRACTOR TO COORDINATE ALL WORK WITH THE
RESPECTIVE TRADES AND VERIFY LOCATIONS FROM THE
ARCHITECTURAL DRAWINGS AND FIELD MEASUREMENTS
AND SUPPLIER SHOP DRAWINGS.
6. CONTRACTOR TO VISIT THE SITE TO DETERMINE THE
FUL: EXTENT OF THE WORK AND FACILITY
LOCATIONS AND VERIFY WITH GOVERNING BODIES.
� GENERAL NOTES
SCALE
LIGHTING PLAN
ALL H I PM E EX TO BE REUSED
7 OBTAIN AND PAY ALL PERMIT AND INSPECTION FEES
AS REQUIRED FOR THIS PORTION OF THE WORK,
8. LAYOUT IS DIAGRAMMATIC AND CONTRACTOR SHALL
INSTALL EQUIPMENT AND DUCTWORK TO MEET THE
FIELD CONDITIONS AND PROVIDE SHOP DRAWINGS
AS MAY BE REQUIRED FOR THE WORK.
9. ALL DUCTWORK CONSTRUCTION SHALL CONFORM
TO LOCAL CODES AS WELL AS A.S.H.R.A.E. AND
S.M.A.C.N.A. CONSTRUCTION STANDARDS FOR
LOW VELOCITY DUCTWORK CONSTRUCTION AND
N FPA 190-A.
10. BRANCH TAKE -OFFS SHALL HAVE SPUTTER DAMPERS
OR MANUAL DAMPERS FOR ALL SUPPLY OR RETURN
AIR DUCT BRANCHES. ALL MAIN BRANCHES SHALL
HAVE MANUAL DAMPERS.
11. UPON COMPLETION OF INSTALLATION OF VEN fILATION
DUCTS, CLEAN ENTIRE SYSTEM OF RUBBISH, PLASTER,
DIRT, ETC BEFORE INSTALLING GRILLES OR DIFFUSERS.
SYMBOL
DESCRIPTION
c
4)
Im
ccc
EXISTING 70
+-' -- ��-. � .r.w+ �..�..e.• �..�irs -.. - .rte a. _ � � ._ _ ,...�� - -.�,. - ...�-- ��.n.- - — �. . �. ._- ..r .- -- rte . . �.�..-
!1
�-- -- .�- '+ - w.� --w�. �w
PRISMATIC 4 BULB
,a W
~
FLUORESCENT FIXTURE
Z
I
EXISTING 70
PRISMATIC 3 BULB
_ -
w
Q >
7
._-.1Q
FLUORESCENT FIXTURE
f %� I
7x4' PRISMATIC 4 BULB FLUORESCENT
FIXTURE (1) TUBE OPERATING AS A
NIGHT LIGHT.
TYPICAL SUPPLY DIFFUSER
WITH MANUEL DAMPER
TYPICAL RETURN/
EXHAUST GRILLE
I ,
SYMBOL
i t
I�
(T
I
DESCRIPTION
SINGLE POLE SWITCH
( +4'-W A.F F.)
HONEYWELL'MAGICSTAP PROGRAMMABLE THERMOSTAT
OCT3200A1001 OR EQUAL.
COMBINATION EXIT SIGN &
EMERGENCY LIGHT
COMBINATION LIGHT!
EXHAUST FAN (TOILET ROOM)
I
I
?C 2-A RATED FIRE EXTINGUISHER
r
i
2 FIXTURE LEGEND
F l i "
E
I
I
C.:
t
r
c
- I
I
F i
1
,
J
G.C. TO VERIFY ALL EX,STING
CE €LING CONDITIONS AND
ADjlJST AS NFLDED
��
cc
c
4)
Im
ccc
w
+-' -- ��-. � .r.w+ �..�..e.• �..�irs -.. - .rte a. _ � � ._ _ ,...�� - -.�,. - ...�-- ��.n.- - — �. . �. ._- ..r .- -- rte . . �.�..-
0
�-- -- .�- '+ - w.� --w�. �w
Z IT--
,a W
~
Z
c o
L
-..w- - -� '�' --�� �-+w�
w
Q >
J
._-.1Q
rn
�'`�'�...- s... "'w—�
w
Y �
w
�--
Zm�
_
WAY
J
. o
o
C� • '
W
rq p
V
N
CID
Z I U ~ " "
id
Q V 3 ° o
�-
U -
— o
o '0
VaCps�
F Z I
ICU
�
0
0
0
0
,� SOY s�►�Sr
Now ^ �
dw
' s
Ea . t - -•E i_4M - evF jL
E: SPKaw9C% aE - f - E f
�.a l » 4 00 31?4AC* S : - -Wft AW
art 4- ?'- S�J4 njws am I LI
P..wi4 0
aqw,
0410a i%
IIIIIII�
GRS
4 s
A
05�22%10
SAM Ift
�E�2
12. AFTER ADJUSTMENTS HAVE BEEN MADE TO THE
HEATING, VENTILATING AND AIR CONDITIONING SYSTEM,
THE HEATING, VENTILATING AND AIR CONDITIONING
CONTRACTOR SHALL BALANCE THE AIR DISTRIBUTION
SYSTEM, SUBMIT THREE SETS OF DATA OF THE TEST
AND BALANCE TO THE OWNER FOR APPROVAL.
13. ALL NEW DUCTWORK SHALL BE LINED WITH 1' FIBERGLASS
ACOUSTIC LINING, CONSTRUCTED PER SMACNA STANDARDS,
STANDARDS, MAXIMUM 5'4r FLEX DUCTWORK ALLOWED.
14. PROVIDE FACTOR FABRICATED TURNING VANES IN ALL
SQUARE TURN ELBOWS.
15. PROVIDE FLEXIBLE DUCT CONNECTORS BETWEEN DUCTS,
FANS AND AIR HANDLING UNITS AND ALSO IN DUCTS
CROSSING BUILDING EXPANSION JOINTS.
16. NO GRILLES WILL BE INSTALLED IN ANY DOOR NOR WILL
UNDERCUTTING OF ANY DOOR BE PERMITTED,
17. PROVIDE MANUAL DAMPERS AT SUPPLY GRILLES.
18. PROVIDE MECHANICAL VENTILATION h ALL ROOMS
CAPABLE OF SUPPLYING A MINIMUM OF 15 CUBIC FEET PER
MINUTE OF OUTSIDE AIR.
19, G.C. TO COORDINATE WITH SPRINKLER CONTRACTOR ON
ANY ADJUSTMENTS TO EXISTING SPRINKLER SYSTEM. (IF
APPLICABLE)
7
: 1
+-' -- ��-. � .r.w+ �..�..e.• �..�irs -.. - .rte a. _ � � ._ _ ,...�� - -.�,. - ...�-- ��.n.- - — �. . �. ._- ..r .- -- rte . . �.�..-
�- rr. �'w�,�,�- �..- w�.+... �� ��� �.-- .r.�.�.�..
�-- -- .�- '+ - w.� --w�. �w
-..w- - -� '�' --�� �-+w�
- .....r .� —..� - � - .� �..� -� __ �... -- _�._ r•- -..�► .�
��._. -_r- � "1 .ter. +� -. w- +..�. - as+��.� �r .. '1wi�/w����- �f��..�
_� �'_ +�- �
- L
�'`�'�...- s... "'w—�
12. AFTER ADJUSTMENTS HAVE BEEN MADE TO THE
HEATING, VENTILATING AND AIR CONDITIONING SYSTEM,
THE HEATING, VENTILATING AND AIR CONDITIONING
CONTRACTOR SHALL BALANCE THE AIR DISTRIBUTION
SYSTEM, SUBMIT THREE SETS OF DATA OF THE TEST
AND BALANCE TO THE OWNER FOR APPROVAL.
13. ALL NEW DUCTWORK SHALL BE LINED WITH 1' FIBERGLASS
ACOUSTIC LINING, CONSTRUCTED PER SMACNA STANDARDS,
STANDARDS, MAXIMUM 5'4r FLEX DUCTWORK ALLOWED.
14. PROVIDE FACTOR FABRICATED TURNING VANES IN ALL
SQUARE TURN ELBOWS.
15. PROVIDE FLEXIBLE DUCT CONNECTORS BETWEEN DUCTS,
FANS AND AIR HANDLING UNITS AND ALSO IN DUCTS
CROSSING BUILDING EXPANSION JOINTS.
16. NO GRILLES WILL BE INSTALLED IN ANY DOOR NOR WILL
UNDERCUTTING OF ANY DOOR BE PERMITTED,
17. PROVIDE MANUAL DAMPERS AT SUPPLY GRILLES.
18. PROVIDE MECHANICAL VENTILATION h ALL ROOMS
CAPABLE OF SUPPLYING A MINIMUM OF 15 CUBIC FEET PER
MINUTE OF OUTSIDE AIR.
19, G.C. TO COORDINATE WITH SPRINKLER CONTRACTOR ON
ANY ADJUSTMENTS TO EXISTING SPRINKLER SYSTEM. (IF
APPLICABLE)
7