HomeMy WebLinkAboutPermit D05-404 - BAKER COMMODITIES - GREASE STORAGE TANKSBAKER COMMODITIES 5795 S 130 PL D05 -404 z 6 UO U) LL W 2 gQ co _C I— _. z 0 U0 0 — co C1 I- = U. O W.. U =. z. City O.'Tukwila Department of Comnnirnity Developnient 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: ci.tukwila.wa.us DEVELOPMENT PERMIT Parcel No.: 0001400005 Address: 5795 S 130 PL TUKW Suite No: Tenant: Name: BAKER COMMODITIES Address: 5795 S 130 PL, TUKWILA WA Owner: Name: BAKER COMMODITIES INC Address: 4020 BANDINI BLVD, LOS ANGELES CA Contact Person: Name: BEN CAMERON Address: PO BOX 58368, SEATTLE WA Contractor: N Name: C H G BUILDING SYSTEMS, INC Address: P.O. BOX 78448, SEATTLE, WA Contractor License No: CHGBUSI124BH Steven M. Mullet, Mayor Steve Lancaster, Director Permit Number: Issue Date: Permit Expires On: D05 -404 12/14/2005 06/14/2006 Phone: Phone: 206 243 -7387 Phone: Expiration Date: 07/14/2006 DESCRIPTION OF WORK: TO INSTALL 6 GREASE STORAGE TANKS INTO EXISTING CONTAINMENT LAGOON. THE LAGOON IS 50' W X 100' L X 4' DEEP. THE TANKS ARE ON OUR PROPERTY. Value of Construction: $220,000.00 Type of Fire Protection: NONE Type of Construction: Fees Collected: $3,411.39 International Building Code Edition: 2003 Occupancy per IBC: 0025 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: N Hauling: N Start Time: End Time: Land Altering: N Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: N Moving Oversize Load: N Start Time: End Time: Sanitary Side Sewer: N Sewer Main Extension: N Private: Public: Storm Drainage: N Street Use: N Profit: N Non - Profit: N Water Main Extension: N Private: Public: Water Meter: N doc: IBC - Permit D05 -404 Printed: 12 -14 -2005 Z �Z � QQ 2. JU U0 CO 0U_ w 0 9-1 LL �D 1: W ZF �_0 Z�_ W LLJ Do U CO 0—. 0 F_ wW LL z. W F - CO O Z City o�Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: ci.t:tkwila.wa.its * *continued on next page ** Steven M. Mullet, Mayor Steve Lancaster, Director dom IBC - Permit D05 -404 Printed: 12 -14 -2005 Z �W u� D J U' U Cl) U` W =: CO) LL. W O. J U- <: _CY FW Z = H Z F- LLJ � p' U O � H = V H F- tL O LLI Z , . U CO: H H O Z City o. ' Tukwila Steven M. Mullet, Mayor Departmew of Conimitnity Developmew 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: cOukwila.wa.us Permit Number: Issue Date: Permit Expires On: Steve Lancaster, Director D05 -404 12/14/2005 06/14/2006 Permit Center Authorized Signature: Date:� I hereby certify that I have read and ami a this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit. Signature: Date: Print Name: & e� " � This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Q Z Q 2 Z. �W Q � W U. UO t o D wi J H- CO LL W O J LL Q �d = w i— O Z 2 o ff. U O N � I— wW O ii Z t UN O Z doc: IBC - Permit 005 -404 Printed: 12 -14 -2005 1 ' City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 PERMIT CONDITIONS Parcel No.: 0001400005 Permit Number DOS -404 Address: 5795 S 130 PL TUKW Status: ISSUED Suite No: Applied Date: 11/10/2005 Tenant: BAKER COMMODITIES Issue Date: 12/14/2005 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: The special inspections and verifications for concrete construction shall be required. 5: The special inspections for steel elements of buildings and structures shall be required. All welding shall be done by a Washington Association of Building Official Certified welder. 6: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 7: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 8: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 9: Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 10: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department of Labor and Industries (206/248- 6630). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. * *continued on next page ** doc: Conditions D05 -404 Printed: 12 -14 -2005 z �w JU UO Cl) o LLJ_ H �LL w� J LL j � = w z� E- O z�- W UJ Do U ON o�- w W tL O w U= z 1 �...Q Cit y of Tukwila f9C6 Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 I hereby certify that I have read these conditions and will compiy with them as outlined. All provisions of law and ordinances j governing this work will be complied with, whether specified herein or not. 4 The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: _ Date: wit /ism /� i doc: Conditions D05 -404 Printed: 12 -14 -2005 z z~ Z 0 0, N O w= J f.. N u WO U - �d = W Z �. �- O'. z H 2 5, U13 O N. o �- Ww H L). u- O LLi z U to O z N J� WILA, k� = o 19pB CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 900 Tukwila, WA 98988 W C LA W Building Permit No. V o�;' q lJL` Mechanical Permit No. Public Works Permit No. Project No. ftl")� " 0 21 LIE Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: 000 14 0- 0 0 0 5-06 Site Address: 5 7 9 5 S 13 0 th P 1 Suite Number: Floor: Tenant Name: Baker Commodities New Tenant: ❑ ..... Yes ❑..No Property Owners Name: Baker Commodities Inc. Mailing Address: 4020 Bandini B1 Los Angeles CA 90023 City State Zip CONTACT PERSON Name: Ben Cameron Day Telephone 206- 243 -7387 Mailing Address: PO Box 58368 Seattle WA 98138 City State Zip E - Mail Address: bcameron@bakercommodities.com Fax Number 206 -243 -3412 GENERAL CONTRACTOR INFORMATION - (Mechanical Contractor information on back page) Company Mailing A Contact Person: City state Zip Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance" ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record Company Name: Mailing Address: City state zip Contact Person: Day Telephone: E -Mail Address: Fax Number: ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Anderson - Peyton Mailing Address: 31620 23rd Ave S, Suite 321 Federal Way WA 98003 City state zip Contact Person: Todd M. Phillips P. E. Day Telephone: 253-941-9929 E -Mail Address tphillips@anderson-peyton.com Fax Number 253 -941 -9939 q: %\permits plus\ice changes\pc mit application (7.2004) Revised: 6.8.05 Page I bh Z a , W QQ� JU UO W W C0 u_ W° �QQ LL ? = W F- Z 1— O Z 1— W U� ON O F- WW O .. Z W U= O Z 4. BUILDING PERMIT INFORMATION - 206 -431 -3670 Valuation of Project (contractor's bid price): $ 2 2 0 , 0 0 0 Existing Building Valuation: $ N / A Scope of Work (please provide detailed information): To install 6 tanks into existing containment lagoon. The lagoon is 50'W x 100'L x 4'Deep The tanks are on our property. Will there be new rack storage? ❑..Yes ® ... No If "yes ", see Handout No. for requirements. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single- family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ ....Yes ❑ ..No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑.. Sprinklers ❑..Automatic Fire Alarm 91 -None [:]..Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? El.. Yes ®.. No If "yes ", attach list of materials and storage locations on a separate 8 -112 x I1 paper indicating quantities and Material Safety Data Sheets. gAVetmits pluslicc changeatpennit application (7.2004) Revised: 6.8.05 bh Page 2 FK :u• ' (` �.. ,J v 34..a alJ:.rr ..`t�e.d,'. , i, :.i;. ": i; �.��' ., G. . v7.F.:zs..•4.. :.Ss.u:,,r._ti.i.:, : a:. ^ %.tr, Z = z J 0 Cl) CO LU J X N L WO L J Q = d W 2 Z� F- O Z f- �5 U .O N � F- WW �- O Z U= O Z Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1" Floor 2 d Floor Y Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single- family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ ....Yes ❑ ..No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑.. Sprinklers ❑..Automatic Fire Alarm 91 -None [:]..Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? El.. Yes ®.. No If "yes ", attach list of materials and storage locations on a separate 8 -112 x I1 paper indicating quantities and Material Safety Data Sheets. gAVetmits pluslicc changeatpennit application (7.2004) Revised: 6.8.05 bh Page 2 FK :u• ' (` �.. ,J v 34..a alJ:.rr ..`t�e.d,'. , i, :.i;. ": i; �.��' ., G. . v7.F.:zs..•4.. :.Ss.u:,,r._ti.i.:, : a:. ^ %.tr, Z = z J 0 Cl) CO LU J X N L WO L J Q = d W 2 Z� F- O Z f- �5 U .O N � F- WW �- O Z U= O Z Call before you Dig: 1- 800 -424 -5555 PUBLIC WORKS PERMIT INFORMATION - 206- 433 -0179 Scope of Work (please provide detailed information): To install 6 grease storag ta nks into existing containment lagoon. Anderson - Peyton Structural Enctineering has done the calculations for the foundation. Geotech Consultants has done the geotechnical recommendations for the Foundation. Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ ...Tukwila ❑ ... Water District #125 ❑ - Highline ❑ .. Renton ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila ❑ ... Va1Vue ❑ .. Renton ❑ .. Seattle ❑ ...Sewer Use Certificate ❑ ... Sewer Availability Provided ❑ .. Approved Septic Plans Provided ❑ ...Septic System - For onsite septic system, provide 2 copies of a current septic design approval by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size - 22" x 34 ") ❑ ...Technical Information Report (Storm Drainage) ❑ .. Geotechnical Report ❑ ...Traffic Impact Analysis ❑ ...Bond ❑ ..Insurance ❑ .. Easement(s) ❑ .. Maintenance Agreements) El-Hold Harmless Proposed Activities (mark b oxes t hat a pp) ❑ ...Right -of -way Use - Nonprofit for less than 72 hours ❑ ...Right -of -way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right -of -way Non Right -of -way _ ❑ ...Total Cut cubic yards ❑ ...Total Fill cubic yards ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities ❑ ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection _ Irrigation Domestic Water ❑ .. Right -of -way Use - Profit for less than 72 hours ❑ .. Right -of -way Use - Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑ .. Abandon Septic Tank ❑ .. Curb Cut ❑ .. Pavement Cut ❑ .. Looped Fire Line ❑ ...Permanent Water Meter Size... WO# _ ❑ ...Temporary Water Meter Size.. WO# _ ❑ ...Water Only Meter Size............ WO# _ ❑ ...Sewer Main Extension ............Public Private ❑ ...Water Main Extension .............Public Private ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding ❑ ...Deduct Water Meter Size ........ " FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ ...Water ❑ ...Sewer ❑ ...Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: City State Zip Water Meter Refund/Billing: Name: Day Telephone: Mailing Address: City State Zip q:\tpcnnits pluslice chsages\petmit application (7 -2004) Revised: 6.805 Page 3 bh Z ;�.. z W. �0 UO. C0 W NO J f- N jL W } J. U. C0 a =W Z I- F- O Z I- W O N. D !< WW �U LL. ~O W Z O ~. Z MECHANICAL PERMIT INFORMATION - 206 - 431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New .... ❑ Replacement .... ❑ Electric ..... ❑ Gas .... ❑ Fuel Type Other: Indicate type of mechanical work being installed and the quantity below: Unit Type: Qty Unit Type: Qty Unit Type: Oty Boiler/Compressor: Qty Furnace<100K BTU Air Handling Unit >I0,000 Fire Damper 0 -3 HP /100,000 BTU CFM Furnace>100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected Thermostat 15 -30 HP /1,000,000 BTU to Single Duct Suspended/Wall/Floor Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Mounted Heater Appliance Vent Hood and Duct Water Heater 50+ HP /1,750,000 BTU Repair or Addition to Incinerator - Domestic Emergency Heat/Reftig/Cooling Generator System Air Handling Unit Incinerator — Comm/Ind Other Mechanical <10 000 CFM I I I Equipment PERMIT APPLICATION NOTES - Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR A CGtivL(/LG ORIZED AGENT: Signature: �(%�. _ � -_ Date: 11 -9 -05 Print Name Ben Cameron Day Telephone: 206- 243 -7387 Mailing Address: PO Box 58368 Seattle WA 98138 City State Zip Date Application Accepted: Date Application Expires: f�S /�o' Staff Initials: ul� q: \\permits plua\icc changeatpermit application (7.2004) Revised: 6.8.05 Page 4 bh <r:_ ..t. :; .w.f> i.r,,: t,f. }1.' .: aff.: c�. rs: t:., �..., r:_ rze. �. M:.. 1.aait::.',r�t.Rne.! « + <�i�;ai<: 1J z'✓. �::. «.r. > >'.kr:�,.tc•i�� t•r�iti �: t . n .. � . %N ;..+,: v J" nfA7�,.s �.u.r '!� >r>x e:w:'�Any Cr.4•; .<.+�ly ,l•r;itm �'. fi;p,.q, ac..:.at':.n .Fi.fLe. iis'��.�� Z — Z �W QQ� JU UO CO) C0 W J� Co LL WO J LL Q lA _ d H W ' Z F- F- O W H. �5 U� O� �H W 2 1— u. O Z W U= O F- Z I �..Q City of Tul�wlla 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 i I j Parcel No.: Address: Suite No: Applicant: 0001400005 5795 S 130 PL TUKW BAKER COMMODITIES Receipt No.: R05 -01769 Initials: LAW User ID: 1630 Payment Amount: Payment Date: Balance: 2,069.28 12/12/2005 11:23 AM $0.00 Payee: BAKER COMMODITIES INC TRANSACTION LIST: Type - - - - -- Method Description - - - - -- Amount -- - - - - -- ---------- �----------- - - - - -- Payment Check 122530 2,069.28 ACCOUNT ITEM LIST: Description Account Code Current Pmts r ------------------------ - - - - -- ---------- - - - - -- ------ - - - - -- j BUILDING - NONRES 000/322.100 2,064.78 s STATE BUILDING SURCHARGE 000/386.904 4.50 i Total: 2,069.28 :1:2/13 ?716 TQ iL 2069 -20 20 doc: Receipt Printed: 12 -12 -2005 RECEIPT Permit Number: Status: Applied Date: Issue Date: D05 -404 APPROVED 11/10/2005 Z Z M W UO N o w =' J f.. Cl) U- WO U. to �w Z = t-- t— O Z i•--, w � o U 0 it WW HU LL O .. Z W U 3 Z City o f Tukwi l a 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 J (206) 431 -3670 RECEIPT Parcel No.: 0001400005 Permit Number: Address: 5795 S 130 PL TUKW Status: Suite No: Applied Date: Applicant: BAKER COMMODITIES Issue Date: DOS -404 PENDING 11/10/2005 Receipt No.: R05 -01640 Payment Amount: 1 Initials: 7EM Payment Date: 11/10/2005 12:12 PM User ID: 1165 Balance: $2,069.28 I Payee: BAKER COMMODITIES, INC. TRANSACTION LIST: Type Method Description Amount ---- - - - - -- -- - - - - -- --------------------- - - - - -- ------ - - - - -- j Payment Check 122030 1,342.11 j ACCOUNT ITEM LIST: Description Account Code Current Pmts i -------------------- ---- - - - - -- ---------- - - - - -- ------ - - - - -- j PLAN CHECK - NONRES 000/345.830 1,342.11 i Total: 1,342.11 Z Z W : JU UO. Cl) CO J F. N LL WO J LL cf)d = W r~ _ Z� t•- O. Z I-- �O O N.. CI �- =U tL O .Z W U= ~O F- Z 9206 a/10 R16 'rOTAL 1342-11. doc: Receipt Printed: 11 -10 -2005 INSPECTION RECORD Retain ircopy with permit ' l , --lea INSPECTION NO. PE I O CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: Type of Inspection: Address: ate Calle : Special Instructions: Date Wanted: a.m. p.m. Reques Phone No: y C Approved per applicable codes. F-1 Corrections required prior to approval. Inspector Date: $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Receipt No.: Date: i i Z Z �W g. D JU UO O W= N L, w U. U� = Cy h W Z F- H O Z F- W LU D p'. U O N 01— W LI J H� L O Z W U= Z INSPECTION RECORD ''Z _ GH Retain a copy with permit INSPECTION NO. PE I NO CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Corrections required prior to approval f� 1 Inspector: Date• / Coll $5 EINSPECTIO EE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Project Type of In Ad ress: Date Called: Special Instructions: Date Wanted: a p.m. Requester: Phone No: Receipt No.: Date: l I Z W JU 00 CO D to LL W O E. LL N� = CY W Z� 1— O W ~ W U� O -. 0 I' WW H� O: W Z U =. O Z INSPECTION RECORD Retain a copy with permit INSPECTION NO. PER T NO S� CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 'ect: Type of Iry4 ection: l Pr Aadre n/ Date Called: Special Instructions: Date Wanted: M. Phone No: a-D � 3 - 7 Approved per applicable codes. Corrections required prior to approval. COMMENTS: . onx ^fd'e a.e t a W i or: Date: 8.00 REINSPECTION E REQUIRED Prior to inspection, fee must be d at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Receipt No.: I Date: Z I jp W JU UO CO co W W = S2 LL W O LLQ CO) = F.. W Z F- �O Z H W ON o F- WW F-F- �Z llJ U co z RECEIVED MAYES TESTING ENGINEERS, INC FEB 2 2 2U�6 Tac S. Tacoma Way Product: Concrete Ibs -«- .w ».....•- COMMUNITY DEVELOP Op Suite E•2 Tacoma WA 98499 Ticket Number: 606740 ph 253.584.3720 CONCRETE LABORATORY TEST REPORT fax 253.584.3707 Project Name: Baker Commodities Grease Storage Tanks Project No: T5318 Site Address: 5795 S 130th Place Issued on: 02/16/06 (ASTM C231) Sample Set ID: 10279 Seattle, WA Water /Cement Ratio:' Slump (ASTM C143)' Client: Baker Commodities Permit # (s): 005 -404 6 Original: d 4 x 8 Engineer: Anderson Peyton Structural Engineers Revised: 12.63 Contractor: CHG Building Systems NA ' 02/15/06 FIELD DATA 4 x 8 67925 ASTM C31 and C172 12.63 5380 Air Temperature: 43 °F Design Mix Proportions: Weather Overcast Placement Location and Notes: Holding tank f o u ndation footing. Ingredient Coarse Aggregate 3/4" Fine Aggregate Water Fly Ash Cement - -Type I & II W R DA -64 ADVA Required Strength ft): 3000 psi @ 28 days Weight (per cu.yd) 1,955.0 Ibs 1,395.0 Product: Concrete Ibs Supplier: Stoneway 450.0 Ticket Number: 606740 oz MixDesign ID: 4852A 0216 Sample Temp. Initial Storage Temp. Entrained Air (ASTM C1064) (ASTM C31) (ASTM C231) 62 °F NR NR Water /Cement Ratio:' Slump (ASTM C143)' Sample(s) Recd: ' 0.434 6 01/19/06 Placement Location and Notes: Holding tank f o u ndation footing. Ingredient Coarse Aggregate 3/4" Fine Aggregate Water Fly Ash Cement - -Type I & II W R DA -64 ADVA Required Strength ft): 3000 psi @ 28 days Weight (per cu.yd) 1,955.0 Ibs 1,395.0 Ibs 230.0 Ibs 80.0 Ibs 450.0 Ibs 21.2 oz 10.6 oz Date Made Sample # Lab # 01/18/06 0001 0213 01/18/06 ` 0001 0214 01/18106 0001 0215 01/18/06 0001 0216 Remarks: Dia (in) Surface Inspector(s): Pratt, C. Tested by: Brooks, M. Reviewed by: Jennis Sanborn Branch Manager NOTES: Failure descriptions for samples tested with neoprene pads are not required per ASTM Std. " NA = Not Applicable, S = Shear, C = Cone, CSp = Cone and Split, CSh = Cone and Shear, Col = Columnar, FC - Field Cure, NR = Not Recorded All testing performed in accordance with applicable ASTM's except C -31, 10.1.2 - "recording field temperature Information in this report applies only to the actual samples tested and shall not be reproduced without the approval of Mayes Testing Engineers, Inc. MTE Form #150, Rev 3, 7-0 Z '~ w � QQ � JU UO (3. V) CQ U_ WO �_J LL j. C = w H z H O WW �p O N. �H W W. H H O ui Z U= O Z COMPRESSION TEST RESULTS (ASTM C39, C1231, and C617 when applicable) Date Tested Age Size (in) Load (Ibs) Dia (in) Surface Strength (psi) Failure Code 01/25/06 7 4 x 8 45605 3.99 12.50 3650 NA " 02/15/06 28 4 x 8 64705 4.01 12.63 5120 NA ' 02/15/06 28 4 x 8 67925 4.01 12.63 5380 NA " 02/15/06 28 Ax 8 64295 4.01 12.63 5090 NA " Inspector(s): Pratt, C. Tested by: Brooks, M. Reviewed by: Jennis Sanborn Branch Manager NOTES: Failure descriptions for samples tested with neoprene pads are not required per ASTM Std. " NA = Not Applicable, S = Shear, C = Cone, CSp = Cone and Split, CSh = Cone and Shear, Col = Columnar, FC - Field Cure, NR = Not Recorded All testing performed in accordance with applicable ASTM's except C -31, 10.1.2 - "recording field temperature Information in this report applies only to the actual samples tested and shall not be reproduced without the approval of Mayes Testing Engineers, Inc. MTE Form #150, Rev 3, 7-0 Z '~ w � QQ � JU UO (3. V) CQ U_ WO �_J LL j. C = w H z H O WW �p O N. �H W W. H H O ui Z U= O Z i v 1,395.0 Product: MAYES TESTING ENGINEERS, INC JAN u 917e 13�h Street SW Stoneway 450.0 r�; E Suite A•1 oz MixDesign ID: 4852A Lab # Sample Temp. Initial Storage Temp. i i CO&J& �� �� Everett WA 98204 ph 0 J (ASTM C31) CONCRETE LABORATORY TEST REPORT fax 25.745.1 37 Project Name: Baker Commodities Grease Storage Tanks Project No: T5318 Site Address: 5795 S 130th Place Issued on: 01/26/06 _ 28 4 x 8 - Sample Set 1D: 10279 0001 Seattle, WA 02/15/06 28 ± Client: Baker Commodities Permit # (s): 005 -404 0001 0216 Original: d 28 Engineer: Anderson Peyton Structural Engineers Revised: ea er. v 1,395.0 Product: Concrete Ibs Supplier: Stoneway 450.0 Ticket Number: 606740 oz MixDesign ID: 4852A Lab # Sample Temp. Initial Storage Temp. i i Entrained Air (ASTM C 1064) J (ASTM C31) (ASTM C231) 62 °F NR NR Water /Cement Ratio:' Slump (ASTM C143) ` Sample(s)Redd: ' 0.434 6" 01/19/06 Contractor: CHG Building Systems FIELD DATA ASTM C31 and C172 Air Temperature: 43 °F W fin 0 ercast - Design Mix Proportions: � Ingredient Coarse Aggregate 3/4" Fine Aggregate Water Fly Ash Cement - -Type I & II W R DA -64 ADVA Required Strength ft): Placement Location and Notes: Holding tank foundation footing. i 3000 psi @ 28 days Weight (per cu.yd) 1,955.0 Ibs 1,395.0 Ibs 230.0 Ibs 80.0 Ibs 450.0 Ibs 21.2 oz 10.6 oz Surface Strength (psi) Failure Code 12.50 3650 NA " 0.00 NA ' 0.00 NA ' 0.00 NA ' Inspector(s): Pratt, C. Tested by: Edmonds, B. Reviewed by: Dennis Sanborn Branch Manager NOTES: Failure descriptions for samples tested with neoprene pads are not required per ASTM Std. " NA = Not Applicable, S = Shear, C = Cone, CSp = Cone and Split, CSh = Cone and Shear, Col = Columnar, FC - Field Cure, NR = Not Recorde All testing performed in accordance with applicable ASTM's except C -31, 10.1.2 - "recording field temperature Information in this report applies only to the actual samples tested and shall not be reproduced without the approval of Mayes Testing Engineers, Inc. MTE Form #150, Rev 3,7-0 Z ,= z �w QQ om. J U UO N � J = H W LL w g LL N CY =w ? F- H O Z F- 5 U� O N: 3 H W W. F �. LL Z LLI U= ~O h- Z COMPRESSION TEST RESULTS (ASTM C39, C1231, and C617 when applicable) Date Made Sample # Lab # Date Tested Age Size (in) Load (Ibs) Dia (in) 01/18/06 0001 0213 01/25/06 7 4 x 8 45605 3.99 ..01/18/06 ; _ 0001 0214 02/15/06 _ 28 4 x 8 - 0.00 01/18/06 0001 0215 02/15/06 28 4 x 8 0.00 01/18/06: 0001 0216 02/15/06 28 4 x 8 0.00 Remarks: Surface Strength (psi) Failure Code 12.50 3650 NA " 0.00 NA ' 0.00 NA ' 0.00 NA ' Inspector(s): Pratt, C. Tested by: Edmonds, B. Reviewed by: Dennis Sanborn Branch Manager NOTES: Failure descriptions for samples tested with neoprene pads are not required per ASTM Std. " NA = Not Applicable, S = Shear, C = Cone, CSp = Cone and Split, CSh = Cone and Shear, Col = Columnar, FC - Field Cure, NR = Not Recorde All testing performed in accordance with applicable ASTM's except C -31, 10.1.2 - "recording field temperature Information in this report applies only to the actual samples tested and shall not be reproduced without the approval of Mayes Testing Engineers, Inc. MTE Form #150, Rev 3,7-0 Z ,= z �w QQ om. J U UO N � J = H W LL w g LL N CY =w ? F- H O Z F- 5 U� O N: 3 H W W. F �. LL Z LLI U= ~O h- Z r r 'FC MAYES TESTING ENGINEERS, INC r• Everett Office '1 ^{t,� ; 917 -134th Street SW 2 3 (Ulf Suite A -1 ' Everett, WA 98204 CO E OPNF- T ax 425.7451737 MTE NO: T5318 0� I PROJECT: BAKER COMMODITIES GREASE STORAGE TANKS Tacoma Office th 10029 S. Tacoma Way Address: 5795 S 130 Place Suite E -2 Tukwila, WA Tacoma, WA 98499 PERMIT NO: 005 -404 ph 253.584.3720 fax 253.584.3707 Page 2 Portland Office g 7911 NE 33rd Drive Suite 190 Portland, 1. 97211 Owner: Baker Commodities ph 503.281.7515 Architect: Anderson-Peyton fax 503.281.7579 Engineer: Anderson - Peyton Structural Engineers Contractor: CHG Building Systems Date: 1 -18 -06 Weather: Overcast Inspection: Reinforced Concrete Samples: (4) 4 x 8" MTE inspector arrived on site and completed reinforcing steel inspection of holding tank footing at central location of jobsite per details on approved plans. Previous report written on 1/4/06 is no longer a preliminary inspection report due to the fact that the #4's below embeds were placed per detail on 3 on page S2.0. Checked clearances and cleanliness prior to concrete placement. Observed the placement of 126'/2 cubic yards of Stoneway Concrete Mix # 4852 -A at footings mentioned above. Concrete placed by pump truck with mechanical consolidation by vibration. A composite sample was taken and a set of (4) 4 x 8" cylinders was cast for strength verification. Placement started after 10:00am due to 2 different pump breakdowns. To the best of our knowledge, items inspected this date are in accordance with approved plans and specifications. INSPECTOR: Chris Pratt Reviewed by: i cc: Ben Cameron, Baker Commodities Ben Sessions, CHG Building Systems Todd Phillips, Anderson - Peyton Structural Engineers } James Dunaway, City of Tukwila i Dennis Sanborn, Branch Manager z = Z '~ w 00 0 w= J H U) U_ w 9 _ U_ (n0 = w z O' w Ljj D0 U o CO_ ff w w ti z U =. O ~. z l A MAYES TESTING ENGINEERS, INC. RECEIVED 1. MTE NO: T5318 COMMUNITY DEVELOPMENT PROJECT: BAKER COMMODITIES GREASE STORAGE TANKS Address: 5795 S 130 Place Tukwila, WA PERMIT NO: '005 -404 Page 1 Owner: Baker Commodities Architect: Anderson - Peyton Engineer: Anderson - Peyton Structural Engineers Contractor: CHG Building Systems Date: 1-4 -06 Weather: Cloudy Inspection: Resteel Samples: N/A Everett Office 917 -134th Street SW Suite A -1 Everett, WA 98204 ph 425.742.9360 fax 425.745.1737 Tacoma Office 10029 S. Tacoma Way Suite E -2 Tacoma, WA 98499 ph 253.584.3720 fax 253.584.3707 Portland Office 7911 NE 33rd Drive Suite 190 Portland, OR 97211 ph 503.281.7515 fax 503.281.7579 MTE inspector arrived on site to perform resteel inspection for new grease storage tank foundation. Resteel in place at this time is per plan. Embeds for tank attachment have yet to be installed. After embed installation Mayes Testing will need to verify that the (2) #4 x 4' -0" are installed at each embed, per detail 3 of the plans, prior to the concrete placement. PRELIMINARY: INSPECTOR: Tom Robinson Reviewed by: a"., 94, O ennis Sanborn, Bfanch Manager z ;F Z W QQ � JU UO. U 0: co = J I— N U. W O U_ ¢ = CY. �w Z F _ O. z H w � o. U O C0 oI__ W uj u-- O ..z w U= O F- z cc: Ben Cameron, Baker Commodities i Ben Sessions, CHG Building Systems Todd Phillips, Anderson - Peyton Structural Engineers ` James Dunaway, City of Tukwila I i 1 j i I a 000 Anderson -Peyton Sheet Cover of 3z� 000 Structural En Consultants Date: 9/29/05 000 A Division gFACP Consultants Design By: TMP Structural Calculations These calculations are provided as part of a submittal for the construction of a foundation to support (4) 11'0 x 40' tall, (2)13'0 x 34' tall and '(1) 6'0 x 8' tall storage tanks. Tanks are considered to have continuous bearing around it's perimeter with equal distribution of load. The design of each tank to support it's own weight including contents is not within the scope of Anderson - Peyton's work. Foundation is designed to support both gravity and lateral loads induced from the tanks themselves. Foundation is cast directly over art existing slab on grade over native soil per the project soils report. Project & Location: Structurat:Calculations for: Baker... Commodities Storage Tanks Tukwila, WA Client: Baker Commodities, Inc. P.O. Box 58365 Seattle, WA 98138 �.� Structural Anderson - Peyton Engineer: Structural Engineering ediisultants o. 31620 23rd Avenue South, Suite 321 Federal Way, WA 98003 Project Number: 05.205 Code: Loads: I. Vertical Loads: 2 total load at 6'0 tank 217 total load at l l'O tank 214 total load at 13'0 tank H. Lateral Loads (Wind): Exposure `B" Wind Speed = 85 MPH (3 Second Gust) Importance Factor, I =1.0 III. Lateral Loads (Seismic): Seismic Design Category "D" Site Class "E" Seismic Use Group I Spectral Response Acceleration: REVT_�.AlED FOP S 1.394g �QD� � \JPJJANCE S�= 0.483- a T% Importance Factor, I =1.0 D�0 - 72005 RECEIVED CITY OF TUKWILA NOV 1 0.2005 PERMIT CENTER 0. 9 23112 1 0NAI EXPIRES 4116/ oCi � 7 2003 IBC Z �Z '~ W � JU UO N �W wo J W ?. CO d �W Z W O E W 2p U 0 E- W F_ U. O Z w U CO) OH Z Anderson Peyton SirtictitralEtigitteeringConsultants A Division of ACP Consultants, Inc. 77 PROJECT JOB # DESIGNED CHECKED Z, SHEET OF DATE DATE 31620 23rd Avenue South. Suite 321, Federal Way, NVA 98003 • Phone: (253) 941-9929 Fax: (253) 941-9939 Seattle / Eastside (206) '_92 -0940 z Z 00 C O) 0 CO) w LLJ 3: -J H to LL W O LL co CY W Z 1-0 z ]�- LU Uj 93 L) W. 0 131-- LLI Lu X C. ) 0 Z U cf) z r 1.300 1.400 MCE Ground Motion - Conterminous 48 States Latitude = 47.49789, Longitude = - 122.250717 j Period MCE Sa 1 (sec) ( %9) S; 0.2 139.4 MCE Value of Ss, Site Class B 1.0 048.3 MCE Value of S1, Site Class B y 064.4 Spectral Parameters for Site Clas 0.2 5 ,., 125.4 Sa = FaSs, _ 1.0 S :115.9 Sa = FvS1 pv= 057.9 Spectrum for Site Class E Period MCE Sa T; (sec) ( %9) c� ss " -. -1 0.000 050.2 T = 0.0, Sa = 0.4FaSs 0.185 125.4 T = To, Sa = FaSs �1 0.200 125.4 T = 0.2, Sa = FaSs 0.924 125.4 T = Ts, Sa = FaSs 1.000 115.9 T = 1.0, Sa = FvS 1 1.100 105.4 . - ".1 1.200 096.6 r 1.300 1.400 089.1 082.8 LO .:. 1.500 077.3 S S I 1.600 072.4 1.700 068.2 1.800 064.4 / ^ j 1.900 061.0 _ i 2.000 057.9 0 3 z Z u�D UO � o; w =. U; U_ cf) D = w z �. A O. w D o U 0 H. w � U; 111 z 0 z tj 0130 Anderson - Peyton JOB # SWEET Or 000 Structural Engineering Co its it Ita tits 000 A DivisionofACIlConsultanis. Inc. DESIGNED DATE PROJECT CHECKED DATE 31620 23rd Avenue South, Suite 321, Federal Way, WA 98003 • Phone: (253) 941-9929 Fax: (253) 941-9939 Seattle / Easiside (206) 292.0940 z F- 1 Z w 2 6:3. 3 U 00 Cl) a CIO w W:E CO) LL 0 LL < Uj Z F- 0 z F- w LLJ fy C0 0 0 F- LLI w M F- 0 z C0 O F-' z Anderson - Peyton Structural Engineering Consultants A Division orACP Consultants, Inc. -7 PROJECT JOB # DESIGNED CHECKED SHEET OF DATE DATE 31620 23rd AvellLIC South, Suite 321, Federal Way, WA 98003 • Phone: (253) 941-9929 Fax: (253) 941-9939 Seattle / Easiside (206) 292-0940 z I U U 0 Cl) 0 1 C0 w LU 3: J �— C0 U. 0 co CY W. Z �0 — z -� .w LU co � 43 H w w O. z CO) 0 z X 13 0 Anderson - Peyton JOB # SHEET OF 0710 Structural Engineering Consultants 13:30 A Division ot'ACPConsullams. Inc. DESIGNED DATE PROJECT CHECKED DATE Z Z: Uj: 00. Cl) a. U) w W 3: J H U) LL W O J . co W Z F- I- 0 z �-� W Uj 5 U C6 :0 o ff W W L ) LL 0 iii Z co 0 F- .z 31620 23rd AvellLIC South, Suite 321. Federul Way, NVA 98003 • Phone: (253) 941-9929 Fax: (253) 941-9939 Seattle / Eastside (200) 292-0940 000 Anderson - Peyton 000 Structural Engineering Consultants 000 A Division of ACP Consullautts, Inc. PROJECT JOB # DESIGNED CHECKED SHEET OF DATE DATE 31620 23rd Avenue South. Suite 321, federal Way. WA 98003 - Phone: (253) 941 -9929 Fax: (253) 941 -9939 Scuttle / Easiside (206) 292 -0940 Z ;f— Z �W .� U UO. CO J CO) LL, W O LLQ C _. _CY F... W Z H F- O Z I - �p U O N �H W LU 2 F- H LL O LLI Z U N 1= _ O H Z - 000 Anderson - Peyton 0730 Structural Engineering Consultants 0710 A Division ofAC!'Consultants, Inc. PROJECT JOB # DESIGNED CHECKED SHEET OF DATE DATE 31620 23rd Avenue South, Suite 32l, Federal Way, WA 98003 • Phone: (253) 941 -9929 Fax: (253) 941-9939 Seattle / Eastside (206) 292-0940 Z Z w U 00 N0. CO) w W 3: J H CQ LL 0 LL <. U) :3 CY. W 0 Z F— W W 5 U cf)l 0 0 F— UJ uj � LL 0 Z. 0 Z j J 000 Anderson - Peyton JOB # 000 0 structural Engineering Cr�nsultauts 00 A Division of ACP Consultants, Inc. DESIGNED SHEET OF DATE PROJECT CHECKED DATE 31620 23rd Avenue South, Suite 321, Federal Way, WA 98003 - Phone: (253) 941 -9929 Fax: (253) 941 -9939 Scuttle / Eastside (206) 292 -0940 z gl Z. '~ w UO U 0 W= J� (0 LL w O. LL = F w Z �- i- O z f- w LU �o o C0 0 �- wW L ..z w U =: O z i l 1 1 , .i i I i ._, , i 7 1-�D 000 Anderson - Peyton JOB# 000 Structural Engineering Consultants 000 A Division of ACP Consultants. Ine. DESIGNED SHEET OF DATE PROJECT CHECKED DATE 31620 23rd Avenue South, Suite 321, Federal Way, WA 98003 • Phone: (253) 941 -9929 Fax: (253) 941 -9939 Seattle / Eastside (206) 292.0940 �5 z '~ w JU UO N 0 W = F— N LL WO J IL Q d = W Z� F- O Z F— �p O -. 0 F— W H O LLI Z U= O Z �}- Z �W aa� JU U O' U 0 J H CO LL WO LL Q Cl) D = CY. �W Z H O. Z 1-- W �p U O cl)' W W H L —O U CO, H H O Z 31620 23rd Avenue South, Suite 321, Federal Way, WA 98003 • Phone: (253) 941 -9929 Fax: (253) 941.9939 Seattle / Gastside (206) 292 -09.10 000 Anderson - Peyton 7170 Structural Engineering Consultants 71013 A Division ofACIlConsultants, Inc. PROJECT JOB # DESIGNED CHECKED %L SHEET OF DATE DATE Z 1� . ' W . JU 00 Cl) a W w LL w 0 2 � 95 LL co) CY W 3: Z t- H 0 Z f- LU Uj 5 cli 0 0 h- . w LU L) L 0 Z� CO) 0 Z 31620 23rd Avenue South, Suite 321, Federal Way, WA 98003 • Phone: (253) 941-9929 Fax: (253) 941-9939 Seattle / Eastside (206) 292-0940 DDD Anderson - Peyton Structural Engineering Consultants JOB # A Division t)I* ACV Ct)iistilitints, Inc. DESIGNED k) SHEET OF DATE PROJECT CHECKED DATE 31620 23rd Avenue Suuth, Suite 321, Federal Way, WA 98003 Phone: (253) 941-9929 Fax: (253) 941-9939 Seattle Easiside (206) 292-0940 �b z Z LLV 00 Cl) 0 CO) W W:C Cl) U- w 0. LL U) m CY F- W z � 0 z P: w a Co. 0-1 0 1-• Uj w L ) LL 0 z F- 0 z z W 6 UO co o CO w w = H CO LL, W O' J . LL. a = d �w z� �-- O z F- w �o o� 0 H W 4 - O. LLi z U= O z 7 13130 Anderson - Peyton 000 Structural Engineering Consultants 000 A Division ofACPConsultants. Inc. PROJECT JOB # DESIGNED CHECKED IT SHEET OF DATE DATE 3162023rd Avenue SOLIIII. Suite 321, Federal Way, WA 98003 Phone: (253)941-9929 Fax: (253) 941-9939 Seattle Eastside (206) 292.0940 Z Z w 3 L) 0 cf) 0 C0 LLI C0 U- w O M� :3' LL < Cl) M 3: a W 3: Z P F— 0 z �-- LLI LU 5 13 N" 0 W Ui U- F- 0, z fli Cl) 0 Z i i 1 i 1 '.0 000 Anderson - Peyton JOB# Structural Engitteerittg Cousultauts 000 A Division of ACP Consultants Inc. DESIGNED PROJECT CHECKED SHEET OF, DATE DATE Z Z �W Q � JU UO CO) p W= JH CO) LL ,W O �Q N� +(3 W Z H I- O Z F-' 5 O N. LJJ p F— = U H LL O W Z U= O Z 31621) 23rd Avenue South, Suite 321, Federal Way, WA 98003 • Phonc: (253) 941 -9929 Fax: (253) 941 -9939 Seattle / Eastside (206) 292 -0940 i 1 I 7 Y i i I 1) Title : Job # . Dsgnr: Date- 7:52AM, 29 SEP 05 Description Scope : n e v: anuuuu User: KW- 0604293, Ver5.8.0, 1- Dec -2003 Beam on Elastic Foundation Page 1 (01963.2003 ENERCALC Engineering Software footing design.ecw:Load in N/S directio Description Footing Design with 11' and 13' tank (1.OD + .7E) Max Shear 7.16 k at General Information Defi:a 0.168 in R:a 0.00 k Beam Span 30.000 ft Elastic Modulus 3,122.0 ksi Load Factodnq... R:b Depth 24.00 in Subgrade Modulus 100.00 pci Dead Loads 1.000 Width 12.00 in I Gross 13,824.00 in4 Live Loads 1.000 Left End Fixity Free Beta 3.287 Short Term Loads 1.000 Right End Fixity Free Overall Factor 1.000 Load Combination DL +LL +ST 0.000 ft Theta:a Deflections Calc'd using Unfactored Loads 0.000 ft Min SP 0.00 psf at 0.000 ft Rotations Calc'd using Unfactored Loads Rotations Calc'd using Unfactored Loads Soil Pressure Calc'd using Factored Loads Uniform Loads Deflections Calc'd using Unfactored Loads #1 Dead Load 0.300 k/ft Live k/ft Short Term k/ft Start X 0.000 ft End X ft #2 Dead Load 1.315 k -ft Live k -ft Short Term k -ft Start X 2.000 ft End X 13.000 ft #3 Dead Load 1.103 k/ft Live k/ft Short Term k/ft Start X 15.000 ft End X 28.000 ft #4 Dead Load k/ft Live k/ft Short Term 0.171 k/ft Start X 2.000 ft End X 13.000 ft #5 Dead Load k/ft Live k/ft Short Term 0.144 k/ft Start X 15.000 ft End X 28.000 ft Point Loads Dead Load Live Load Short Term Load Location #1 k k 15.80 k 5.170 ft #2 k k -15.80k 9.830 ft #3 k k 11.20 k 18.740 It #4 k k -11.20 k 24.260 ft Max Shear 7.16 k at 15.000 ft Defi:a 0.168 in R:a 0.00 k Min Shear -10.42 k at 5.280 ft Defl:b 0.017 in R:b 0.00 k -Max Moment 26.28 k -ft at 18.720 ft Max Defl 0.00 in at 0.000 ft Ma 0.00 k -ft Min Moment -27.90 k -ft at 9.840 ft Min Defl -0.17 in at 0.000 ft Mb 0.00 k -ft Max Rotation 0.00057 rad at 23.280 ft Max SP 2,414.16 psi) at 0.000 ft Theta:a 0.00036 rad Min Rotation 0.00000 rad at 0.000 ft Min SP 0.00 psf at 0.000 ft Theta:b 0.00053 rad Rotations Calc'd using Unfactored Loads Deflections Calc'd using Unfactored Loads Soil Pressure Calc'd using Factored Loads z Z �W W W UO I N 0 W= � CO W � O. LL co = d. p.. W Z F- �- O Z F- W �O O N � F- W W S L Z : L) O Z I . I ' i �I r 000 Anderson - Peyton 000 Structural Engineering Consultants 000 A Division ol'ACP Consultants. Inc. PROJECT ly JOB # SHEET Of, DESIGNED DATE CHECKED DATE z 3: J U U O N(3 W =. J �. N LL W O LL a' c� = �W X Z F- r-- O z f- U� O N D H- 2U H — LL F' O W z U =; O z 31620 23rd Avenue SOUth, Suite 321, Federal Way, WA 98003 • Phone: (253) 941 -9929 Fax: (253) 941 -9939 Scuttle / Gastside (206) 292 -0940 i i '1 i 1� DOO Anderson - Peyton 000 Structural Engineering Consultants 000 A Division of ACP Consuluuits, Inc. PROJECT JOB # DESIGNED CHECKED SHEET OF DATE DATE 31620 23rd Avenue South, Suite 321, Federal Way, WA 98003 • Pitone: (253) 941 -9929 Fax: (253) 941 -9939 Seattle / Eastside (206) 292 -0940 zz S Z w JU UO <n o J = H N LL. WO 1L to = �. w Z F- F - O z w U 5 O cf) O H w H LL. O: ui z U N' z Title : Job # Dsgnr: Date: 7:56AM, 29 SEP 05 Description Scope Page 1 Rev: 580001 User: KW- 0604293 Ver5.8.0. 1- Dec -2003 (c11983.2003 ENEf�CALC Engineering Software Single Span Beam Analysis I footing design.ecw:Load In N/S directio Description 1.2D + 1.0E (Ultimate Loads) General Information u Center Span 30.00 ft Moment of Inertia 1,000.000 in4 Q - Left Cantilever ft Elastic Modulus 29,000 ksi J U . Right Cantilever ft Beam End Fixity Pin - Pin V 0 CO Uniform Loads w W On Center Span... On Left Cantilever... On Right Cantilever... N I.- LL # 1 0.360 k/ft # 1 k/ft # 1 k/ft W O ' Point Loads Magnitude 22.500 k - 22.500 k 15.900 k - 15.900 k k LL Location 5.170 ft 9.830 ft 18.740 ft 24.260 ft It = CY F- W Trapezoidal Loads z H Magnitude ® Left 1.578 k/ft 1.317 Wit -3.090 k/ft 0.245 Wit Z O Magnitude @ Right 1.578 k/ft 1.317 Wit -0.290 k/ft 0.245 Wit W W j Dist. To Left Side 2.000 ft 15.000 ft ft 2.000 ft j 0 Dist. To Right Side 13.000 ft 28.000 ft 30.000 ft 13.000 ft N Magnitude ® Left 0.205 k/ft Wit k/ft k/ft Z Magnitude @ Right 0.205 k/ft k/ft k/ft k/ft U j Dist. To Left Side 15.000 ft ft ft ft LL -0 Dist. To Right Side 28.000 ft ft ft ft Query Values v ~O --- Center Location 0.000 ft Left Cant 0.000 ft Right Cant 0.000 ft F- ' Moment 0.00 k -ft 0.00 k -ft 0.00 k -ft Z Shear 0.12 k 0.00 k 0.00 k Deflection 0.00000 in 0.00000 in 0.00000 in I Summary Moments... Shears... Reactions... Max + @ Center 38.1Dk at 18.76 ft ® Left 0.12 k @ Left 0.12 k Max - @ Center -42.at 9.86 ft ® Right 0.18 k @ Right -0.18 k Maximum 30 k } @ Left Cant 0.00 k -ft Right Cant 0.00 k -ft Deflections... Center -0.027 in at 19.72 ft Maximum = 42.22 k -ft ® Left Cant. 0.000 in at 0.00 ft Right Cant 0.000 in at 0.00 ft Ll 38.17 30.63 22.90 16.27 7.63 0.0 .8.44 E -26.33 -3.).78 -42.22 95 5.95 .66 T.96 14.97 17.98 26.98 23.99 26.99 3 ).0 Location (ft) In X1 0.0 B +"71 Location (ft) 8.41 6.30 4.20 2.10 0.0 .3.06 -0.01 .0.01 -12.24 -15.30 0.0 B +"71 Location (ft) 0.014 -0.00 -0.01 .0.01 .0.02 -0.02 -0.03 95 595 8.96 14.97 17.98 20.98 23.99 215.99 3 0.0 B +"71 Location (ft) 1pr , z Z w uo. C 6 0 CO w W:C J �- U- 0 2� 9-1 U- < Co D Cy UJ Z }- 0 z F- UJ U J 5 CO 0- 0 F- LU W 3: C. ) F-- U- z Cf) 0 z 0.014 -0.00 -0.01 .0.01 .0.02 -0.02 -0.03 1pr , z Z w uo. C 6 0 CO w W:C J �- U- 0 2� 9-1 U- < Co D Cy UJ Z }- 0 z F- UJ U J 5 CO 0- 0 F- LU W 3: C. ) F-- U- z Cf) 0 z r s i f r ' i f r 7 i I 1 i Title : Dsgnr: Description Scope : Job At Date: 8:OOAM, 29 SEP 05 ZZ nev. aouuuu User: KW- 0604293. Ver5.8.0, 1- Dec•2003 Beam on Elastic Foundation age 1 IN (c11983.2003 ENERCALC Engineering Software footing design.ecw:Load in N/S directio Description Footing Design with 11' and 13' tank (1.2D + 1.OE) Max Shear 10.01 k at General Information Defi:a 0.221 in R:a Beam Span 30.000 ft Elastic Modulus 3,122.0 ksi Load Factoring... Depth 24.00 in Subgrade Modulus - 100.00 pci Dead Loads 1.000 Width 12.00 in I Gross 13,824.00 in4 Live Loads 1.000 Left End Fixity Free Beta 3.287 Short Term Loads 1.000 Right End Fixity Free 6.960 ft Max SP Overall Factor 1.000 Load Combination DL+LL +ST 0.00055 rad Min Rotation 0.00000 rad at Deflections Calc'd using Unfactored Loads 0.00 psf at 0.000 ft Theta:b Rotations Calc'd using Unfactored Loads Soil Pressure Calc'd using Factored Loads Uniform Loads Deflections Calc'd using Unfactored Loads #1 Dead Load 0.360 k/ft Live k/ft Short Term k/ft Start X 0.000 ft End X ft #2 • Dead Load 1.578 k -ft Live k -ft Short Term k -ft Start X 2.000 ft End X 13.000 It #3 Dead Load 1.317 k/ft Live k/ft Short Term Wit Start X 15.000 ft End X 28.000 ft #4 Dead Load k/ft Live k/ft Short Term 0.245Wft Start X 2.000 ft End X 13.000 ft #5 Dead Load k/ft Live k/ft Short Term 0.205 k/ft Start X 15.000 ft End X 28.000 ft Point Loads Dead Load Live Load Short Term Load Location #1 k k 22.50 k 5.170 ft #2 k k -22.50 k 9.830 ft #3 k k 15.90 k 18.740 ft #4 k k -15.90 k 24.260 ft Max Shear 10.01 k at 15.000 ft Defi:a 0.221 in R:a 0.00 k Min Shear -14.99 k at 5.280 ft Defl:b 0.008 in R:b 0.00 k Max Moment 36.28 k -ft at 18.720 ft Max Defl 0.00 in at 0.000 ft Ma 0.00 k -ft Min Moment -41.04 k -ft at 9.840 ft Min Dell -0.22 in at 0.000 ft Mb 0.00 k -ft Max Rotation 0.00081 rad at 6.960 ft Max SP 3,177.68 psf at 0.000 ft Theta:a 0.00055 rad Min Rotation 0.00000 rad at 0.000 ft Min SP 0.00 psf at 0.000 ft Theta:b 0.00070 rad Rotations Calc'd using Unfactored Loads Deflections Calc'd using Unfactored Loads Soil Pressure Calc'd using Factored Loads z = z LIJ 0 W� CO W W O u. Q co S F- W Z = H- ir O. Z H W U O co. 01- LLI =U H� LL O .. Z W U= O Z -J 0013 Anderson - Peyton 0130 Structural Engineering Consultants 000 A Division ofACI'Consultants, Inc. PROJECT JOB # DESIGNED CHECKED 13 SHEET OF DATE DATE 31620 23rd Aven tic South, Suite 321, Federal Way, WA 98003 • Phone: (253)941-9929 Fax: (253) 941-9939 Seattle / Eusiside (206) 292-0940 Z Z W ! 0: 0,0 Cl) 0, W W' C0 LL W LL to W Z 0 z � W W: 5 U C) !0 CI), LU W : 3: LL 0: Z. Cl) 0 Z i 1 ._t i , 2`t 000 Anderson - Peyton 000 Structural Engineering Consultants 000 A Division of ACP Consultants, Inc. JOB # SHEET OF DESIGNED DATE CHECKED DATE PROJECT Z �Z 'w w .j U U O, N W= CO U WO U . N d F-W Z— = H Z O W U� ON 0 E- W W H �. �O W Z N 1= � z 31620 23rd Avenue South, Suite 321, federal Way, WA 98003 • Phone: (253) 941.9929 Fax: (253) 941 -9939 Scathe / Eastside (206) 292.0940 Z�5 Title : Job # Dsgnr: Date: 8 :24AM, 29 SEP 05 Description Scope : I 1 s s 2- �i 1 ! z Max Shear 7.85 k at User: ZV 04293. Ver5.8.0, 1•Dec -2003 Beam on Elastic Foundation 43.798 it Page 1 39.400 ft (c)1983.2003 ENERCALC Engineering Software 10.800 ft Max Rotation 0.00063 rad at footing design.ecw.Load in EJW directio Description (3) tank configuration (D +0.7E) 11' diameter for determining maximum soil bearing Rotations Calc'd using Unfactored Loads 0.00 k -ft pressure Min Defl Soil Pressure Calc'd using Factored Loads Mb 0.00 k -ft General Information Beam Span 50.000 ft Elastic Modulus 3,122.0 ksi Load Factodnq... Depth 24.00 in Subgrade Modulus 100.00 pci Dead Loads 1.000 Width 12.00 in I Gross 13,824.00 in4 Live Loads 0.000 Left End Fixity Free Beta 5.479 Short Term Loads 1.000 Right End Fixity Free Overall Factor 1.000 Load Combination DL +LL +ST Deflections Calc'd using Unfactored Loads Rotations Calc'd using Unfactored Loads Soil Pressure Calc'd using Factored Loads Uniform Loads #1 Dead Load 0.300 k/ft Live k/ft Short Term k/ft Start X 0.000 ft End X 50.000 ft #2 Dead Load 1.315 k -ft Live k -ft Short Term k -ft Start X 2.830 ft End X 13.830 ft #3 Dead Load 1.315 k/ft Live k/ft Short Term k/ft Start X 19.500 ft End X 30.500 ft #4 Dead Load 1.315 k/ft Live k/ft Short Term k/ft Start X 36.170 ft End X 47.170 ft Point Loads Dead Load Live Load Short Term Load Location #1 k k 15.80 k 6.000 ft #2 k k -15.80k 10.660 ft #3 k k 15.80k 22.660 ft #4 k k -15.80k 27.320 ft #5 k k 15.800 k 39.32 ft #6 k k -15.80k 43.980ft ! z Max Shear 7.85 k at 36.200 ft Min Shear -12.12 k at 43.798 it Max Moment 42.04 k -ft at 39.400 ft Min Moment -31.46 k -ft at 10.800 ft Max Rotation 0.00063 rad at 43.400 ft Min Rotation - 0.00014 rad at 18.600 ft Rotations Calc'd using Unfactored Loads 0.00 k -ft Deflections Calc'd using Unfactored Loads Min Defl Soil Pressure Calc'd using Factored Loads Mb Z U O' N � W =. J F- U 0 U- = CY FW Z �. O Z H W LLJ �p O N ' LLJ � H =U ~ F- u. O Z UN H � O Z Defl:a 0.134 in R:a 0.00 k Defl:b 0.007 in R:b 0.00 k Max Deli 0.00 in at 0.000 ft Ma 0.00 k -ft Min Defl -0.13 in at 0.000 ft Mb 0.00 k -ft Max SP 1,925.82 at 0.000 ft Theta:a 0.00026 rad Min SP 0.00 psf at 0.000 ft Theta:b 0.00059 rad i i Title : Job # Dsgnr: Date: 8:24AM, 29 SEP 05 Description zk.7 Scope : s i i I HOW 5tl000U User: KW 0604293, Ver 5.8.0, 1- Dec -2003 Beam on Elastic Foundation Page 1 (c)1983.2003 ENERCALC Engineering Software tooting design.ecw:Load in E/W direct,. Description (3) tank configuration (D +0.7E) 11' diameter for determining maximum moment in footing General Information 36.200 ft Defl:a 0.175 in R:a Beam Span 50.000 ft Elastic Modulus 3,122.0 ksi Load Factoring... Depth 24.00 in Subgrade Modulus 100.00 pci Dead Loads 1.200 Width 12.00 in I Gross Ma 13,824.00 in4 Live Loads 0.000 Left End Fixity Free Beta 0.000 ft 5.479 Short Term Loads 1.430 Right End Fixity Free 2,520.85 psf at 0.000 ft Overall Factor 1.000 Load Combination DL +LL +ST Min SP 0.00 psf at Deflections Calc'd using Unfactored Loads 0.00081 red Rotations Calc'd using Unfactored Loads Rotations Calc'd using Unfactored Loads Deflections Calc'd using Unfactored Loads Soil Pressure Calc'd using Factored Loads Uniform Loads Soil Pressure Calc'd using Factored Loads #1 Dead Load 0.300 k/ft Live k/ft Short Term k/ft Start X 0.000 ft End X 50.000 ft #2 Dead Load 1.315 k -ft Live k -ft Short Term k -ft Start X 2.830 ft End X 13.830 ft #3 Dead Load 1.315 k/ft Live k/ft Short Term k/ft Start X 19.500 ft End X 30.500 ft #4 Dead Load 1.315 k/ft Live k/ft Short Term k/ft Start X 36.170 ft End X 47.170 ft Point Loads Dead Load Live Load Short Term Load Location #1 k k 15.80 k 6.000 ft #2 k k -15.80 k 10.660 ft #3 k k 15.80 k 22.660 ft #4 k k -15.80k 27.320 ft #5 k k 15.800 k 39.32 ft #6 k k -15.80 k 43.980ft Max Shear 10.61 k at 36.200 ft Defl:a 0.175 in R:a 0.00 k Min Shear -17.21 k�] at 43.798 ft Defl:b 0.006 in R:b 0.00 k Max Moment 58.85 k -ft (t � at 39.400 ft Max Defl 0.00 in at 0.000 ft Ma 0.00 k -ft Min Moment -46.19 k -ft at 10.800 ft Min Defl -0.13 in at 0.000 ft Mb 0.00 k -ft Max Rotation 0.00063 red at 43.400 ft Max SP 2,520.85 psf at 0.000 ft Theta:a 0,00041 rad Min Rotation - 0.00014 red at 18.600 ft Min SP 0.00 psf at 0.000 ft Theta:b 0.00081 red Rotations Calc'd using Unfactored Loads Deflections Calc'd using Unfactored Loads Soil Pressure Calc'd using Factored Loads � , �... .. ... ,« - ... .G...,..r,cea: ..;•. .�i:: i4 ..L.:ll':i.:r.:bi'a:�F•nil�,. w2. aw: .::�.....� " <+- aT.:.r,;] ..►.w:.r,.:k =nn +J. ..1..1:•tw�ia:w,G.+, :.i z >` J- Z �w 00 Cl) 0 J H co 1L W O LLQ (1 )d = W H _ Z� Z O W �p LLJ U 0 01- w LL O .. Z, CO) i- X O Z. { j { i i 000 Anderson - Peyton JOB # SHEET OF 000 000 Structural Engineering Consultants A Division of ACP Consultants, Inc. DESIGNED DATE PROJECT - CHECKED DATE CI1': crl A w 5: 5 `-7 7 L—it,r Vr.,�l uu Iir Dq t � C . 11. L .(.. IC ) :1_�(„ ` J!!. ��7 ��... .....` 1. ✓K .... ........... 1i � .7. - __ .... �. tnit• 1. . ._.... ... _.... _ ... _ .: _ .... _ ... _. - .. . _ .... /� 22 241r4 { to / ( Al L, _,?.1.. 21.��` �0.1,63) 8�1. 1 = .h �� # I�O,c, "��° I,11 C 1 J 1 I ....... 31620 231 d Avenue South, Suite 321, federal Way, WA 98003 • Phone: (253) 941 -9929 Fax: (253) 941 -9939 Seattle / Eastside (206) 292 -0940 r� +IT >• + .k r..t, ..:.., >... n «Ss�:r.y:.t�Y:tics.AS. c:'w �'o?;,4i,'� • �Ic�� �u;�,•k+rt+u v, ri Ft+^ z �z '~ w JU UO U13 co w J = U) LL w 0 �J L� D� =w �_ ? I-- WO w U U, O� D H w LL w U= OF z f i i i �.i i" s Title : Dsgnr: Description Scope: Job # Date: 9:05AM, 29 SEP 05 ZY nav: aouwu User: KW- 0604293, Ver5.8.0, 1 -Dec -2003 Beam on Elastic Foundation P age 1 (01983 -2003 ENERCALC Enoineerina Software footinq design.eml-oad In E/W directio Description (3) tank configuration (D +0.7E) two 13' diameter and one 11' diameter tanks for determining maximum soil bearing pressure General Information 40.000 ft Max Defl 0.00 in at 0.000 ft Ma Beam Span 50.000 ft Elastic Modulus 3,122.0 ksi Load Factoring... at Depth 24.00 in Subgrade Modulus 100.00 pci Dead Loads 1.000 Width 12.00 in I Gross 13,824.00 in4 Live Loads 0.000 Left End Fixity Free Beta 0.000 ft 5.479 Short Term Loads 1.000 End Fixity Free 0.00 psf at 0.000 ft Overall Factor 1.000 Load Load Combination DL +LL +ST Deflections Calc'd using Unfactored Loads Deflections Calc'd using Unfactored Loads Rotations Calc'd using Unfactored Loads Soil Pressure Calc'd using Factored Loads Soil Pressure Calc'd using Factored Loads Uniform Loa #1 Dead Load 0.300 k/ft Live k/ft Short Term k/ft Start X 0.000 ft End X 50.000 ft #2 Dead Load 1.097 k -ft Live k -ft Short Term k -ft Start X 2.170 ft End X 15.170 ft #3 Dead Load 1.097 k/ft Live k/ft Short Term k/ft Start X 19.500 ft End X 32.500 ft #4 Dead Load 1.315 k/ft Live k/ft Short Term k/ft Start X 36.830 ft End X 47.830 ft Point Loads Dead Load Live Load Short Term Load Location #1 k k 11.20k 5.920 ft #2 k k -11.20 k 11.440 ft #3 k k 11.20k 23.250 ft #4 k k -11.20 k 28.770 ft #5 k k 15.800 k 40.00 ft #6 k k -15.80k 44.660ft Max Shear 7.54 k at 36.800 ft Defl:a 0.120 in Min Shear -12.26 k at 44.598 ft Defl:b 0.009 in R:a 0.00 k R:b 0.00 k Max Moment 43.45 k -ft at 40.000 ft Max Defl 0.00 in at 0.000 ft Ma 0.00 k -ft Min Moment -25.86 k -ft at 11.400 ft Min Defl -0.12 in at 0.000 ft Mb 0.00 k -ft Max Rotation 0.00067 red at 44.200 ft Max SP 1,720.92 psf at 0.000 ft Theta :a 0.00020 red Min Rotation - 0.00016 red at 19.400 ft Min SP 0.00 psf at 0.000 ft Theta:b 0.00064 rad Rotations Calc'd using Unfactored Loads Deflections Calc'd using Unfactored Loads Soil Pressure Calc'd using Factored Loads I .� .� � .: a.r �,. .. .:. .....e.,..a.. � , n.).,i !.:n.�•: ��.:t: 1.� .f...�,:L•r ,:1.. .:;In .:.rr 11:� ..h..1 <;.Jrt. «w.u. a. �.' n. 4. S, Lw1, v" w' i, fo»'' y�:. ntJ: ?'iG.4.#.i.:Y7iLiv.tl::3'.+t � ' ?i'.S �.�a'•k,.`" -. 2 ' Z w. UO N J H W W W O LLQ to = F. W Z F- Z O W LLI �p U en W u.t - Z llJ U =, O Z 1 ; w i i _r i Z� Title : Dsgnr: Description Scope : Job # Date: 9:05AM, 29 SEP 05 User: KW-0604293, Ver 5.9.0, 1- Dec -2003 Beam on Elastic Foundation Page 1 (c)1963.2003 ENERCALC Engineering Software footing design.emi-oad In E/W directio Description (3) tank configuration (1.2D +1.OE) two 13' diameter and one 11' diameter tanks for determining Ultimate Moment, Shear, etc in footing R:a Min Shear at 44.598 ft General Information C61.06 ft Max Moment at 40.000 ft Min Moment ft at 11.400 ft i .... Beam Span 50.000 ft Elastic Modulus 3,122.0 ksi Load Factoring... i Depth 24.00 in Subgrade Modulus 100.00 pci Dead Loads 1.200 Width 12.00 in I Gross 13,824.00 in4 Live Loads 0.000 Left End Fixity Free Beta 5.479 Short Term Loads 1.430 Right End Fixity Free Overall Factor 1.000 Load Combination DL +LL +ST Deflections Calc'd using Unfactored Loads Rotations Calc'd using Unfactored Loads Soil Pressure Calc'd using Factored Loads Uniform Loads #1 Dead Load 0.300 k/ft Live k/ft Short Term k/ft Start X 0.000 ft End X 50.000 ft #2 Dead Load 1.097 k -ft Live k -ft Short Term k -ft Start X 2.170 ft End X 15.170 ft #3 Dead Load 1.097 k/ft Live k/ft Short Term k/ft Start X 19.500 ft End X 32.500 ft #4 Dead Load 1.315 k/ft Live k/ft Short Term k/ft Start X 36.830 it End X 47.830 ft Point Loads Dead Load Live Load Short Term Load Location #1 k k 11.20 k 5.920 it #2 k k -11.20 k 11.440 ft #3 k k 11.20k 23.250 it #4 k k -11.20 k 28.770 it #5 k k 15.800 k 40.00 ft #6 k k -15.80k 44.660ft Defl:a Max Shear 10.25 k at 36.800 ft R:a Min Shear at 44.598 ft Defl:b C61.06 ft Max Moment at 40.000 ft Min Moment ft at 11.400 ft i .... Max Rotation 0.00067 rad at 44.200 it Max Dail Min Rotation - 0.00016 rad at 19.400 ft ' Rotations Calc'd using Unfactored Loads i Deflections Calc'd using Unfactored Loads -' Soil Pressure Calc'd using Factored Loads Defl:a 0.155 in R:a 0.00 k Defl:b 0.005 in R:b 0.00 k Max Dail 0.00 in at 0.000 it Ma 0.00 k -ft Min Defl -0.12 in at 0.000 ft Mb 0.00 k -ft Max SP 2,231.24 psi at 0.000 ft Theta:a 0.00032 rad Min SP 0.00 psf at 0.000 ft Theta:b 0.00090 rad z ! �z '~ w JU UO CO W N LL W O 9 - LL _ CY t... W z i- ir•- O z F- W U� ON o I- w w: H H LL O 111 z U =. O .z i i i t — I i i i 000 Anderson - Peyton 000 Structural Engineering Cousultarnts 000 A Division ol'ACP Consultants, Inc. PROJECT JOB # DESIGNED CHECKED SHEET OF DATE DATE 3162023rd Avenue South, Suite 321, federal Way, WA 98003 - Phone: (253) 941 -9929 fax: (253) 941 -9939 Seattle / Eastside (206) 292 -0940 3J I Z Z JU UO to O W= W U W O U. ¢ co) = F w Z ��.. F O z i-- 2 -1 U C3 O U); 0 E— w W LL H' O w z 1= _ O f' Z MAYES TESTING ENGINEERS, INC 917-134th Everett Street SW Suite A-1 Everett, WA 98204 June 2 , 2006 ph fax 425.745173 RECEIVED 10029 S. Tacoma Way Cit y of Tukwila �1 /1 5 '�oos ��Ul� V suite a Tacoma, WA 98499 Building Department ph 253.584.3720 6200 South Center Blvd COMMUNITY DEVELOPMENT fax 253.584.3707 Tukwila, WA 98188 Portland Office 7911 NE 33rd Drive Suite 190 Attn.: Building Official Portland, OR 97211 ph 503.281.7515 fax 503.281.7579 Re: Baker Commodities Grease Storage Tanks FINAL LETTER 5795 S 130 Place Permit No. 005 -404 Tukwila, WA MTE Project No. T5318 Gentlemen: This is to inform you that registered special inspections have been completed for this project as per our reports, copies of which have been sent to you. Special inspection was provided for: 1. Reinforced Concrete 2. Structural Steel & Welding To the best of our knowledge, all work inspected was either performed in accordance with, or corrected to conform to, the city approved drawings, or engineer approved changes. We trust that this provides you with the information that you require. Should you have any questions, give us a call. Sincerely, MAYES TESTING ENGINEERS, INC. i Michael S. Dolder, P.E. Vice President MSD:ell Cc: Ben Cameron, Baker Commodities I Ben Sessions, CHG Building Systems Todd Phillips, Anderson - Peyton Structural Engineers j James Dunaway, City of Tukwila , z Z �w 0 0' 00 J = !— �w w 0 U_ ¢ = d. _: z F . }= o z I—: LLI w U � o C o Ir-. wW v z ui O z Date: 5 - 10 - 06 Weather: Cloudy Inspection: Structural Steel Visual Welding Samples: N/A MTE inspector arrived on site to perform visual weld inspection of the connection of the New Tanks to the Foundation Embeds. Looked at the welds connecting the five new tanks to the embeds in the foundation. The welds appear to be per plan and acceptable per AWS D1.1. To the best of our knowledge, items inspected this date are in accordance with approved plans and specifications. INSPECTOR: Tom Robinson Reviewed by: cc: Ben Cameron, Baker Commodities Ben Sessions, CHG Building Systems Todd Phillips, Anderson - Peyton Structural Engineers James Dunaway, City of Tukwila - - re.0 Dennis Sanborn, Branch Manager z W� UO: 0 W =. COU wO J LL ?. �Cf . = w Z H O; w �5 U� co C3 !— W U_ O ui z co O~ z MAYES TESTING ENGINEERS, INC. �� D Everett Office 917 134th Street SW MAY Suite A -1 2 3 �oO� Everett, WA 98204 C eE ph 425.742.9360 � MTE NO: T5318 E 425. 45.1 I PROJECT: BAKER COMMODITIES GREASE STORAGE TANKS �NT Tacoma Office j Address: 5795 S 130` Place Suoe 2Tacoma Way Tukwila WA Tacoma, WA 98499 PERMIT NO: 005 -404 ph fax 253 584 370 Page 3 Portland Office 7911 NE 33rd Drive Suite 190 Owner: Baker Commodities Portland, OR 97211 ph 503.281.7515 Architect: Anderson - Peyton fax 503.281.7579 Engineer: Anderson - Peyton Structural Engineers Contractor: CHG Building Systems Date: 5 - 10 - 06 Weather: Cloudy Inspection: Structural Steel Visual Welding Samples: N/A MTE inspector arrived on site to perform visual weld inspection of the connection of the New Tanks to the Foundation Embeds. Looked at the welds connecting the five new tanks to the embeds in the foundation. The welds appear to be per plan and acceptable per AWS D1.1. To the best of our knowledge, items inspected this date are in accordance with approved plans and specifications. INSPECTOR: Tom Robinson Reviewed by: cc: Ben Cameron, Baker Commodities Ben Sessions, CHG Building Systems Todd Phillips, Anderson - Peyton Structural Engineers James Dunaway, City of Tukwila - - re.0 Dennis Sanborn, Branch Manager z W� UO: 0 W =. COU wO J LL ?. �Cf . = w Z H O; w �5 U� co C3 !— W U_ O ui z co O~ z i Rece I MAY o 8 2006 OC OP E I f May 5, 2006 RE: Permit No D05=404 Jennifer Marshall City of Tukwila Department of Community Development 6300 Southcenter Boulevard Suite #100 Tukwila, WA 98188 Dear Ms. Marshall: Baker Commodities Inc. would like to request a 90 day extension for our tank project at 5795 S 130' Place. The certified welder that is required to complete the installation has been unavailable for a few weeks. He is scheduled to be on site in the next week or two, but if complications in his work schedule should arise we may need the additional time. i One of the tanks we had scheduled for installation has been diverted to another site and is unavailable for installation. Therefore, we will only install five (5) tanks at this time. The last tank will be rescheduled at some future time. i Thank you for your assistance. Sincerely Qe^ Ben Cameron Baker Commodities, Inc : i A ;1 BAKER COMMODITIES INC. QuaNy aiul Paide...lUexPclwkle P.O. Box 58368, Seattle, WA 98138 (206) 243 -7387 FAX (206) 243 -3412 I Z �Z �W UO J = H N LL... W LL = CI; �w Z F-. z 0 LLJ w 1 �o ,0 w W` HU LL. �'- _0 111 Z U =, O Z i i %LA o=r.. { z City of Tukwila u�t i0 N = Department of Community Development 1908 May 16, 2006 Ben Cameron Baker Commodities, Inc. PO Box 58368 Seattle, WA 98138 Steve Lancaster, Director RE: Request for Extension Development Permit No. D05 -404 Baker Commodities - 5795 S 130 PI Dear Mr. Cameron: This letter is in response to your written request for an extension to Permit No. D05.404. The City of Tukwila Building Division will be extending the expiration date of your permit for an additional 90 days (through September 15, 2006). If you should have any questions, please contact our office at (206) 431 -3670. Sincerel , Je n(fer Marshall File: Permit No. D05 -404 Steven M. Mullet, Mayor z u� D . JU U O Cf) ui J � S2 LL w O' L L cf) = (3 �- _ I— O z t- U� O CO � F- w LL O. — Z w U CO O z �. P:VenniferTmension LettersTemutsT05 -404 Pemut Extension.doc Page t of I jem 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 -431 -3670 • Fax. 206 - 431 -3665 I F���E� NAV 0 63 2006 COM May 5, 2006 RE: Permit No. D05 -404 Jennifer Marshall City of Tukwila Department of Community Development 6300 Southcenter Boulevard Suite #100 Tukwila, WA 98188 Dear Ms. Marshall: Baker Commodities Inc. would like to request a 90 day extension for our tank project at 5795 S 130"' Place. The certified welder that is required to complete the installation has been unavailable for a few weeks. He is scheduled to be on site in the next week or two, but if complications in his work schedule should arise we may need the additional time. One of the tanks we had scheduled for installation has been diverted to another site and is unavailable for installation. Therefore, we will only install five (5) tanks at this time. The last tank will be rescheduled at some future time. Thank you for your assistance. Sincerely Ben Cameron Baker Commodities, Inc J6� 011�s1dV BAKER COMMODITIES INC. Qlutatg and Paide...4UoxUUd& P.O. Box 58368, Seattle, WA 98138 (206) 243 -7387 FAX (206) 243 -3412 r I} z � lY Ui . JU U O N o J = H LL LL Nd =w 1— _ 1— O z 1—: W 2 U U ! O U wW H H U- —O w z U =. O F ". z `II I I 1 I 05 -01 -2006 BEN CAMERON PO BOX 58368 SEATTLE WA 98138 City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director RE: Permit No. D05 -404 5795 S 130 PL TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such pemut is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or.if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for additional periods not exceeding 90 days each. Extension requests mist be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 06/17/2006, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, d iZfe rshall, Permit Technician xc: Permit File No. D05404 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206.431 -3670 • Fax. 206 - 431 -3665 ',G......,.. �:....�. .. ;., ..:... � .�.�_, i �,. � ,.. . , e..s ti_,' t. �. .r;�:l.u.�.,..:sr:ila:w..:;w..�» .�,� »hw .:� ..,:� „>,.,W u.....,...,ta� � swa�fiuws .�w�6u:I:tics....w.5;�? „tss`..�.+wt,u.�.•. �':� Z F W JU UO N W= J N W WO F- LQ co d. W ' Z t— F— O Z F— W U J 2 5 Ua Y) � F- W H H �6 --Z W U Cl) O Z 'f ' 1 _ I I a City of Tukwila Department of Community Development Steve Lancaster, Director Steven M. Mullet, Mayor 1908 November 17, 2005 Ben Cameron PO Box 58368 Seattle, WA 98138 RE: Letter of Incomplete Application # 1 Development Permit Application D05404 Baker Commodities — 5795 S 130 Pt Dear Mr. Cameron: This letter is to inform you that your application received at the City of Tukwila Permit Center on November 10, 2005 is determined to be incomplete. Before your application can continue the plan review process the attached items from the following department(s) need to be addressed: Building Deaartment: Ken Nelsen, at 206 431 -3677, if you have any questions concerning the attached memo. Please address the above comments in an itenuzed format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) complete sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. -1 have enclosed one for your convenience. Revisions must be made in person and will not be accented through the mail or by a messenger service. I If you have any questions, please contact me at the Permit Center at (206) 433 -7165. s Sincerely,, i ife arshall Permit Technician Enclosures File: Permit D05404 P:Vennife6incomplete Lcttcrs\D05 -404 Incomplete Ltr #I.DQC z I� tZ a � a JU U Cl) J = H �LL W O LL Q CO = F. W Z F- z i— �5 U� ON 0 H-, W H~ U. F- •• z W CO O F ' z i. 206 - 431.3665 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 * Fax: M Building Division Review Memo Date: November 15, 2005 Project Name: Baker Commodities Permit #: D05 -404 Plan Review: Ken Nelsen, Senior Plans Examiner A Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and /or other applicable documentation. 1. An overall site plan to locate the proposed tanks on the property is required. Should there be questions concerning the above requirements, contact the Building Division at 206 -431 -3670. No further comments at this time. Z Z . �w JU U 0- Cl) o CO Ui J = N u.. w O LL ?. CO a =w Z� �- 0 w ~ w CO 0 o F- wW X U- 8 _z ui o F-' Z .)ERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D05 -404 DATE: 11 -22 -05 PROJECT NAME BAKER COMMODITIES SITE ADDRESS 5795 S 130 PL Original Plan Submittal X Response to Incomplete Letter # 1 Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS Building Vi sion Fire Prevention ❑ A K nn i nAiv s�i o n Public Works ❑ Structural ❑ Permit Coordinator ❑ j DETERMINATION OF COMPLETENESS (Tues., Thurs.) DUE DATE: 11-29-05 I Complete Incomplete ❑ Not Applicable ❑ i Comments: I Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUT NG: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documenlshouling slip.doc 2 -2M2 "f.. ... �. r �;, .C. •�,. c:1. ...i,.; 311.. .W. ati l.,'�i !y ,l � ifs ..r ; ,� �. �. .,. . 1 �:. •t .'.�:i, �..kH li'r.+ir end .xs;x„ . �xa.� � �.t.• - 4 f , .��'s., �d4 �.},,i�.{�.rrw„:b u> >s:: 3�+reti�,;;ir? � r.. is;,rs §: >.fd�! i�l;(�e�.d.%i.;:,*%+3:!i .Sd�a..;.i.4'r+,:«.:�,:� DUE DATE: 1 2-27-05 Not Approved (attach comments) ❑ Z �w QQ JU 00 00 co ILI J I— S2 U_ W 0 9_j U. < co =) =w z� ZO UJ w U� co 0 I— w W. F-F LL 0 iii Z U= O F- Z PERMIT COORD COPS PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D05 -404 DATE: PROJECT NAME BAKER COMMODITIES SITE ADDRESS 5795 S 130 PL 11 -10 -05 X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued P DEPARTMENTS- II✓Is` S u ding ivision Public Wo Not Applicable ❑ 612 h j w Fire Prevention ❑� Structural ❑ DETERMINATION OF COMPLETENESS (Tues., Thurs.) Complete ❑ Incomplete Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: I I ��l O7� LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route ❑ Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: A nnnA \IA t P Afl J nI'%" /•TEA \It• Approved ❑ Approved with Conditions ❑ Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Planning Division d Permit Coordinator ❑ DUE DATE: 11-1 5-05 DUE DATE: 12 -13 -05 Not Approved (attach comments) ❑ Documents/routing slip.doc 2.2M2 L ��. ,�crt= , �d, icxW:.t., �.AM v;G,. «..c1.�.:. +:J:•• '.++>J" u: u. tslwl.' a: a, n:. au. �a.' SaY..: st. s�ti:. J. nU�J.' w .::....,:s,a`.:,J.: �..a.., s. DATE: z �w QQ JU U 0 w= S2 LL w 0 LL Q D) = �w z X F- I— 0 z I_ LLJ U� O co 01— w LLJ I— u" 0 .z W U= z IL City of Tukwila or y Department of Conintimity Development 6300 Southcenter Boulevard, Suite #100 W = Tukwila, Washington 98188 Phone: 206-431-3670 "' 190 Fax: 206 -431 -3665 Web site: http : /Avtiviv.ci.tukwila.wa.its Steven M. Mullet, Mayor• Steve Lancaster, Director REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through 3 the mail, fax, etc. k Date: �'� OS Plan Check/Permit Number D05 -404 i ® Response to Incomplete Letter # 1 ❑ Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner i Project Name BAKER COMMODITIES i j Project Address 5795 S 130 PL i Contact Person Ben Cameron Phone Number: ;�o G - o2 c/3 - 73,q Summary of Revision: _ �� AF X 0g0 o g 1.�wlZ , ;-.r A,14Vib . i e-we OE TUKW1iA ►i n �tI 7 2 91105 PERMIT CENT Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on z z QQ W WD JU UO 0 W= �LL w J LL ?. C = F- w _ z F- �= o Z �5 CO U� o t-- w W F- P �O .z w C.) =. O z pplications forms - applications on lineVevision submittal Created: 8-13-2004 Revised: Z W � JU UO U) O co w J = H CO LL WO UQ N = �. W Z F- F- O Z I- W 25 D U O� o�- WW S I- u' O Z W U= O Z (� ;: �7 "1 ��y1tCl'YrY�,•21U 7 =.,: �.r'Jf. :•. ,.-: .: .. r . tg•rl C � ' .!^ s".�`:Irfi!'C.+ +{.A.rr�.,;w,c�.0 H:4!n:,� .. +. a .y:,r,!�vlr,�:t?.+•.++H:r:.KVr; + �5 Metro Sewer v ault - — ' r loft - - - - - - - - - - - AM e -.._ • t Pu nter Brea t . ■ w •,&L ^inn n a n c / A/4As A' non cutlet not RK i y ` cu Not net Ma r i r " - Mw PERT Y Wv soil "k o w go t acc.,rs E SMT 1W 3 ,Eo,, z ' Con w a u ♦- .... . . ..... Not. Gas asbuifts show 2` gas inn in this Ma p _ _ _ Bid 2444 5F% _ �. cant.• paveftwo r dirt i — /' asP• P~Ient Q G bc. , l it - . lop • l '' Bid ' c°x I cant, i .0,111 S r 1 + CB r Top =!9.3' 1 1 0 light pde t pips r 0 uttlity polo j ! jconc. dirt woods r d r r r r , , � r r j u',16 Pa k wood post asphalt pavement o J r cone j � l .j _ l OW PCVW7Wt LEGENCW : SCE: t' = 40' C8 = CATCH BASIN B`C = EX ' S - : ` BU ! ! D i !'SIG LP = L i Gi P0-E i � C;a = C'S' ►RON P; PE t L = L'ri - ER ! ! N E G - f14AT JRAL GAS :. ' NE w SS - SA''. , TARY SEJ ER �- M ?VOTE BU!' _ 1 AREAS :,RE -ROM 01UTS • DE BU i LC '\IG a F%S L' E L. "�i 0 E R G R v i; N 4 I j T T E S S ij t7 N� H t �v r; a� t �- t :J C .: v J E�� . S T i "'vim SI`�E fto maw a "Ma s a"* � Ne .�ar�°" of a,q'� ,dam � � Of WMyld Rdd CpPy MW � i D E r7 l'A I L S M_M_ D_ M - E�SF,Ut, d ! SC:-iED�`� RECORDING NO DESCR I PT 'ON ?91 2:0905 WATER MA :N EASEMENT 7 0 VVER GIST 125 - -OCAT iO": UNOETERM:NABLE. 85 r . ' i GOi 3l GAS P ; PEL I NE _;.__1 !`T J ',;.ASH' !NATURAL GAS 3359' 213023' O1 30' :DE ACCESS BEVEF : TS GRANTORS TO NO RTH OF SITE_ 2638928 WATER WIN EASEMENT ' 0 734.% Or %Kti ! A - LOW 'ON JWDETERM I NABLE 26,)044 10' :;E 4 MA %- r-ASEEW -NT TO VATEP D'S' 33 - LOCATION UNDETERMINABLE. 284333: BRUS D :Kc EASEMENT -0 VORTH-_:'R% PAC RA!fLROA0 - :OCAT UNDETERMINABLE 559i32- EAS£W:ti" FAR MA.N`A :%ANCE ') :_ ,;_VERT T) MUN.C:QA: '`Y OF METRO SEA' :1 E 35 i 39 J 34 ROAN AY =ASEW_!:' - =aC:•" Ot JFZE7ERMINABLE 74• 2c1,E "75 ` - 3c J "'£ A_: =S{ _A ;_VE1YT `� SEA 7iE RENDERIRK FROM 8 N. +RAILROA3. a . L . T . a . SURVEY OF THE SEATTLE RENDERING WORKS SITE 5 795 SOUTH 130TH. PLACE SEATTLE. WASHINGTON :F\ SURVEI ING PE \'i'0\ . W AS H I N G T 0 El.. 2 5 3-8440 SHEET 2 OF 2 V » • ft :,���_�Tt fwczw r 3 PEt� :,'`cri usam4q(m i � I J -� t SI`�E fto maw a "Ma s a"* � Ne .�ar�°" of a,q'� ,dam � � Of WMyld Rdd CpPy MW � i D E r7 l'A I L S M_M_ D_ M - E�SF,Ut, d ! SC:-iED�`� RECORDING NO DESCR I PT 'ON ?91 2:0905 WATER MA :N EASEMENT 7 0 VVER GIST 125 - -OCAT iO": UNOETERM:NABLE. 85 r . ' i GOi 3l GAS P ; PEL I NE _;.__1 !`T J ',;.ASH' !NATURAL GAS 3359' 213023' O1 30' :DE ACCESS BEVEF : TS GRANTORS TO NO RTH OF SITE_ 2638928 WATER WIN EASEMENT ' 0 734.% Or %Kti ! A - LOW 'ON JWDETERM I NABLE 26,)044 10' :;E 4 MA %- r-ASEEW -NT TO VATEP D'S' 33 - LOCATION UNDETERMINABLE. 284333: BRUS D :Kc EASEMENT -0 VORTH-_:'R% PAC RA!fLROA0 - :OCAT UNDETERMINABLE 559i32- EAS£W:ti" FAR MA.N`A :%ANCE ') :_ ,;_VERT T) MUN.C:QA: '`Y OF METRO SEA' :1 E 35 i 39 J 34 ROAN AY =ASEW_!:' - =aC:•" Ot JFZE7ERMINABLE 74• 2c1,E "75 ` - 3c J "'£ A_: =S{ _A ;_VE1YT `� SEA 7iE RENDERIRK FROM 8 N. +RAILROA3. a . L . T . a . SURVEY OF THE SEATTLE RENDERING WORKS SITE 5 795 SOUTH 130TH. PLACE SEATTLE. WASHINGTON :F\ SURVEI ING PE \'i'0\ . W AS H I N G T 0 El.. 2 5 3-8440 SHEET 2 OF 2 V » • ft :,���_�Tt fwczw r 3 PEt� :,'`cri usam4q(m 1 C 5 c 3 Ic C 1.o GDOK THESE STRUC1URAl NOTES SUPPLEMENT THE SPECIFICATIONS. AN) DISCREPANCY FOUND AMON(• THE DRAWINGS, SPECIFICATIONS, THESE NOTES, AND THE SITE CONDITIONS SHALL BE REPORTED TO THE ARCHITECT, WHO SHALL CORRECT SUCH DISCREPANCY IN WRITING ANY WORK DONE BY THE CONTRACTOR AFTER DISCOVERY OF SUCH DISCREPANC SHALL BE DONE AT THE CONTRACTOR'S RISK THE CONTRACTOR SHALL VERY 'i AND COORDINATE THE DIMENSIONS AMONG ALL DRAWINGS PRIOR TO PROCEEDING WITH ANl WORK OR FABRICATION THE CONTRACTOR IS RESPONSIBLE FOR ALL BRACING AND SHORING OURING CONSTRUCTION 1.1 OODES ALL METHODS, MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE REQUIREMENTS OF THE CITY OF TUKWILA AND: THE 2003 INTERNATIONAL BUILDING CODE (IBC) AS AMENDED AND ADOPTED BY THE CITY OF TUKWILA AND THE STATE OF WASHINGTON: ACI. 318 - 02; A I.S C 9TH EDITION AWS; A.I 1 C 2ND EDITION, AND A.I.S.I 1996 EDITION 1.2 OEM CHIME A VERTICAL LOADS 1. SUSTAINED LOADS 6' DIAMETER TANK W/ CONTENTS 2000 LBS 11' DIAMETER TANK W/ CONTENTS 217,000 LBS 13' DIAMETER TANK W/ CONTENTS 214,000 LBS B LATERAL LOADS: ALLOW 33 INCREASE IN ALLOWABLE SOIL BEARING PRESSURE FOR WIND AND SEISMIC FORCES. LATERAL FORCES ARE TRANSMITTED FROM THE BASE OF EACH TANK TO EMBEDDED PLATES AND FOUNDATIONS, WHERE ULTIMATE DISPLACEMENT IS RESISTED BY PASSIVE PRESSURE OF EARTH AND SLIDING FRICTION OF EARTH. OVERTURNING IS RESISTED BY THE DEAD LOAD OF THE STRUCTURES /FOUNDATION. 1 WIND: EXPOSURE B BASIC WIND SPEED = 85 M.P.H. (3 SECOND GUST). IMPORTANCE FACTOR, Iw = 1.0 SEISMIC IMPORTANCE FACTOR, Is = 1.0 SEISMIC USE GROUP ! MAPPED SPECTRAL RESPONSE COEFFICIENTS, Ss = 1.394 AND S1 = 0.483 SOIL SITE CLASS = E SPECTRAL RESPONSE COEFFICIENTS. SDs = .836 AND SD1 = .773 SEISMIC DESIGN CATEGORY = D SEISMIC RESPONSE COEFFICIENT Cs = 0.279 RESPONSE MODIFICATION FACTOR R = 3.0 1.3 SHOD DUO= SUBMIT SUFFICIENT COPIES OF SHOP DRAWINGS TO ARCHITECT; ENGINEER FOR THE FOLLOWING- 1 REINFORCING STEEL (CONCRETE) 2. CONCRETE MIX DESIGN DO NOT FABRICATE PRIOR TO ARCHITECT'S/ENGINEER'S APPROVAL. ALL SHOP DRAWINGS SUBMITTED TO THE ENGINEER SHALL BEAR THE STAMPED APPPROVAL OF THE CONTRACTOR SHOP DRAWING APPROVAL BY ANDERSON- PEYTON STRUCTURAL ENGINEERS 'SHALL NOT IMPLY THAT THE PROJECT MAY BE BUILT FROM THE SHOP DRAWINGS RATHER. THE PROJECT PLANS SHALL BE USED FOR CONSTRUCTION 2A SM 1= 2.1 901. DATA (W GWIE1304 JIL F&MT J3?S DAM 9 6 MEPAW BY GWI M OOOMTMM NQ FOR LOCA70NS SEE SOILS REPORT. SOIL BEARING 0 CONT. SPREAC FOOTINGS = 2500 PSF. 3.0 COMM 3.1 SAL NORM:, WIE;C -I•+' CONCRETE MEETING THE REQUIREMENTS OF ACI 30 -02 ESTABLISH PROPORTIONS OF CE MENT, COARSE AND FINE A-W-R�_ A'= S. WATER. AND ADMIXTURES TO PRODL) E THE pp OIxPT ES SPECIFIED FOR EACH CONCRETE MI) TYPE PER AC!- 30' ON T*!E B OF PREVIOUS FIELD EXPERIENCE OP 'TRIAL BA'C64c : USE ADMIXTURES IN ACCORDANCE W11T14 THE VANLIFACTOREWS DIRECTIONS. USE AMOUNTS t} WATER - R "_2 4E1M X TORE THAT WI! PERU: PLACING w THCv: - �.>~E : !?►�. `+IJ�iE` :,01dBING IJF �' P��GKL 'H_ aLJ'.�! S► E . EC ARE -I-E. SLUMPS GEC :3?E+ AT THE POON'r Jc F,ACEV !N,,. THE L STRUCTURE US ' ii1 MEC". ANICA Y ,Q•• � R'� WTo-- ' RPM M'NIM,44 `Yz - " f) NC L r?E ~�M E N . - V: 16_ SIN _ _ .0N, :a��y ��EVA�jRE Eh =.1t_ �ti- . r ` ►= = -_ "'�= E N l�iL E W -_ ra `►= : SE _ � � T ✓_ • . _ .. a ma�yy,' fit -- .. a�� � �..:. � -►x= t;�� .� :: au 03ML - Clow let Ac �w IL CE%EN M c - - _lr� C,F -..cc .Y - • M s - r FR U YAIDULS A. WATER RE [)�ICIN A)MIXTURES CONCRETE USING POZZOLITH ADMIXTURE` Ic ; k0DUCE FLOWABLE CONCRETE MAY BE USED WITH THE �% ;INEER'S APPROVAL AND MUST CONFORM TO ASTM -0494 •ullOLITH POLYHEED, POZZOLITH IOOXR, ()R POZZUTECI- POZZOLITH SHALL BE INCORPORATED INTO ALL CON. rE IN EXACT ACCORDANCE WITH THE MANUFACTLIRFP +'ISTRUCTION$. ADMIXTURES AND DOSAGES WIL: v DEPENDING ON CLIMATIC CONDITIONS AND THE CONI` A (R'S ,;OBSITE REQUIREMENTS MAXIMUM SLUMP FOR SU� ONCRETE SHALL NOT EXCEED 8" WITH A MINIMUM OF 1C` : OF POLYHEED PER 100 OUNCES OF CEMENT USE 1'• ;CCORDANCE WITH MANUFACTURER'S RE COMM[ NDATI, N B. AIR ENTRAINMEN_ CONFORM TO ASTM -C260 AND ASIM- C494, MBVR JF 4 RO -AIR BY MASTER BUILDER ENTRAIN 5% + / " 1% A!; VOLUME IN ALL EXPOSED CONCRETE C- OTHER ADMIXTO ; NO OTHER ADMIXTURES PERMITTED UNLESS PRIOR r ROVAL IS GIVEN BY THE ENGINEER NO ADMIXTURES CHLORIDES ARE PERMITTED. 3.5 WIN WOO SIM DETAIL, FABRICATE A J� PLACE PER ACI -315 AND ACI -318. SUPPORT REINFORCEVP_WITH APPROVED CHAIRS, SPACERS, OR TIES. A STEEL REINFORCEMENT SHALL BE NEW, DEFORMED BILLET STEEL, MEETING -STM STANDARD A -615, A -706 AT BOUNDARY ELE!AE! , S; GRADE 60 FOR #3 AND LARGER BARS UNLESS NOTE ` ` ,'ERWISE ON THE PLANS SHOP DRAWINGS SHALL BE MAR►."° ACCORDINGLY AND SUBMITTED TO THE ENGINEER FOR REVIEW PRIOR TO FABRICATION. GRADE 60 REBARS SHALL N'll BE BENT IN FIELD AFTER CONCRETE PLACEMENT. A;.l BEND SHALL BE PER ACI. B. REINFORCEMENT IN ALL WALLS. SLABS, AND FOOTINGS SHALL BE COW OUS AROUND CORNERS OR CORNER BARS PROVIDED BOT .T AND HORIZONTAL C. LAPS: ALL TEN`�I`N SPLICES ARE ACCORDING TO ACI 318, CLASS 6 AND ALL COW- F::;SION SPLICES ARE 30 DIAMETERS FOR f'c GREATER THAN 3000 PS' AND ARE 40 DIAMETERS FOR ''c WHICH IS LESS THAN 3000 PSI, UNLEP_� NOTED OTHERWISE. W Psi. F = 60I� ROAR SIZE 'a- •a � a a 29" ` 36" APPROXIMATE fit -- .. a�� � �..:. � -►x= t;�� .� :: au 03ML - Clow let Ac �w IL CE%EN M c - - _lr� C,F -..cc .Y - • M s - r FR U YAIDULS A. WATER RE [)�ICIN A)MIXTURES CONCRETE USING POZZOLITH ADMIXTURE` Ic ; k0DUCE FLOWABLE CONCRETE MAY BE USED WITH THE �% ;INEER'S APPROVAL AND MUST CONFORM TO ASTM -0494 •ullOLITH POLYHEED, POZZOLITH IOOXR, ()R POZZUTECI- POZZOLITH SHALL BE INCORPORATED INTO ALL CON. rE IN EXACT ACCORDANCE WITH THE MANUFACTLIRFP +'ISTRUCTION$. ADMIXTURES AND DOSAGES WIL: v DEPENDING ON CLIMATIC CONDITIONS AND THE CONI` A (R'S ,;OBSITE REQUIREMENTS MAXIMUM SLUMP FOR SU� ONCRETE SHALL NOT EXCEED 8" WITH A MINIMUM OF 1C` : OF POLYHEED PER 100 OUNCES OF CEMENT USE 1'• ;CCORDANCE WITH MANUFACTURER'S RE COMM[ NDATI, N B. AIR ENTRAINMEN_ CONFORM TO ASTM -C260 AND ASIM- C494, MBVR JF 4 RO -AIR BY MASTER BUILDER ENTRAIN 5% + / " 1% A!; VOLUME IN ALL EXPOSED CONCRETE C- OTHER ADMIXTO ; NO OTHER ADMIXTURES PERMITTED UNLESS PRIOR r ROVAL IS GIVEN BY THE ENGINEER NO ADMIXTURES CHLORIDES ARE PERMITTED. 3.5 WIN WOO SIM DETAIL, FABRICATE A J� PLACE PER ACI -315 AND ACI -318. SUPPORT REINFORCEVP_WITH APPROVED CHAIRS, SPACERS, OR TIES. A STEEL REINFORCEMENT SHALL BE NEW, DEFORMED BILLET STEEL, MEETING -STM STANDARD A -615, A -706 AT BOUNDARY ELE!AE! , S; GRADE 60 FOR #3 AND LARGER BARS UNLESS NOTE ` ` ,'ERWISE ON THE PLANS SHOP DRAWINGS SHALL BE MAR►."° ACCORDINGLY AND SUBMITTED TO THE ENGINEER FOR REVIEW PRIOR TO FABRICATION. GRADE 60 REBARS SHALL N'll BE BENT IN FIELD AFTER CONCRETE PLACEMENT. A;.l BEND SHALL BE PER ACI. B. REINFORCEMENT IN ALL WALLS. SLABS, AND FOOTINGS SHALL BE COW OUS AROUND CORNERS OR CORNER BARS PROVIDED BOT .T AND HORIZONTAL C. LAPS: ALL TEN`�I`N SPLICES ARE ACCORDING TO ACI 318, CLASS 6 AND ALL COW- F::;SION SPLICES ARE 30 DIAMETERS FOR f'c GREATER THAN 3000 PS' AND ARE 40 DIAMETERS FOR ''c WHICH IS LESS THAN 3000 PSI, UNLEP_� NOTED OTHERWISE. W Psi. F = 60I� ROAR SIZE SPLICE LENGTH. L E 29" ` 36" APPROXIMATE 43� D. TRIM REINFORCINS AROUND ALL OPENINGS SHALL BE A MINIMUM 1 - #5 i!� AND BOTTOM, EXTENDING 2' -6" BEYOND OPENING AT EACH- CORNER. SEE TYPICAL DETAILS E. WELDING: TACK WELDING OF REBAR IS NOT PERMITTED UNLESS CALLE ' : 'R AND APPROVED BY THE ENGINEER. F. MINIMUM REINF! ►R WHERE REINFORCEMENT IS NOT SHOWN ON THE: D AWINGS, THE 'BUILDING CODE REOUIREMENT< REINFORCED CONCRETE' (ACI 318) SHALL BE REF - YRED TC FOR PROPER REINFORCEMENT G. REBAR COVER %lDE CO PROTECTION FOR REINFORCEMEN FOLLOWS. COYER COwTION 2' ALL CONDITIONS AT FOUNDATION U C T U Ft A L N O T E H- REINFORCEMEN" A_� OWANCE- THE CONTRACTOR SHALL PROVIDE AN A_- , "NANCE FOR ADDITIONAL REINFORCEMENT WHICH MAY Or- VAY NOT BE PLACED AT THE DIRECTION OF THE PROJECT EN tNEER. �0 mums 41►1 Ml A ALL WELDING :- A--- BE IN ACCORDANCE WITH AWS D1.1 - STR CTURAL WELDING C. A C, - "STRUCTURAL WELDING CODE - SHEET STEE: » B. ALL WELDING BE DONE By AWS.!WA (WASHINGTON ST =TL ASSCCIATION °U!LE %INS OFF IC!ALS) CERTIFIED WEL C . ADD' - '�1A, -- WE:G+N;C Mtn BE R 3iiIREG FROM THA S.' ;;.►T TuE HTAI! 7 '-NN` `ON THE JOINT CONFIGURA ilON. SPL .E , LCrATiONS _ - _ +. �E':�_ LACES. ET;.. THE CDNTFAC.TOR StiA� DETERMINE . _C►� ATI__ OF ALL FIELD WELDS AND SUBM:' THEM F�>I✓ A _ ,�' • �' _ - � Rc 1A!NI�i''c' �WF'EcE 1FP >_ = SSi?_z C THE MINNiA_IV 1►r ?!_ C yH B E WF_.'� � BE MADE 7 `lA -�•nF IC {ti £L_C Wig;= 1rM►v'ul.l� `�.5+_� '"`_ ► SNAIL ELE_ �= ='��_. � .:S_ E R A WS _ • ` .. 7 E WELD+ PC _ _ x : SN ?� �J3Al�' "I _ JWNEC' - _ "�• _ A z_ CIP EaE_ �_• A w COAF_� _ +. CIF__. _ �+•+_L 3, ��TPar' 1J..,AL 7Z L 1lP0'+i 1�• B V_ _ A�'_ Wf ";,� c �_•.� C0 N - .. cc ;z_ or LIM t ti:_� :: �,� -F_+c: S :L S►• F= L - -C'W`� E�= &0 SINVIR M Spa A ALL DETAILING, FABRICATION, AND ERECTION SHALL CONFORM TO THE AISC "MANUAL OF STEEL CONSTRUCTION" STEEL SHALL CONFORM 10 THE FOLLOWING, UNO. CHANNELS EMBED MENTS ASTM A36, Fy = 36ksi OR IN CONCRETE AND MISC. STEEL TYPES LISTED UNDER METALS, UNO "ALL STEEL" NEL SON WE LDED HEAD STUD ASTM A108 Fy = 51kSi B ALL WORK SHALL BE IN ACCORDANCE WITH THE AISC SPECIFICATION SHOP DRAWINGS SHALL BE SUBMITTED TO THE ARCHITECT /ENGINEER BEFORE COMMENCING FABRICATION. ALL STEEL ANCHORS AND TIES AND OTHER MEMBERS EMBEDDED IN CONCRETE OR MASONRY SHALL BE LEFT UNPAINTED. DIMENSIONAL TOLERANCE FOR BUILD -UP MEMBERS SHALL BE PER AWS )1 1 GENERAL NOTES FOR STEEL CONNECTIONS SHALL APPLY TO ALL STEEL CONNEi. TIONS. UNO. C METAL PROTECTION - ALL MISCELLANEOUS STEEL AND HARDWARE EXPOSED TO VIEW OR IN UNHEATED PORTION OF BUILDING SHALL BE GALVANIZED PER ASTM A -123 WITH 1 25 07 OF ZINC SPELTER PER SCUARE FOOT OF SURFACE AREA ALL OTHER STEEL SURFACES TO BE SHOP PAINTED AFTER FABRICATION Lo speca NSPEIC110115. SPECIAL INSPECTIONS SHALL CONFORM TO SECTION 1702 AND 1704 OF THE 2003 IBC AND ARE REQUIRED DURING THE FOLLOWING A THE TAKING OF CONCRETE TEST SPECIMENS. 6 THE PLACEMENT OF REINFORCING STEEL, TENDONS AND PRESTRESSING STEEL OF ALL STRUCTURAL FOOTINGS, COLUMNS. WALLS, SLABS AND APPENDAGES. PRIOR TO CONSTRUCTION THE CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE A SCHEDULE OF REQUIRED INSPECTIONS AND SHALL SUBMIT THIS SCHEDULE TO THE ARCHITECT AND ENGINEER FOR APPROVAL. 7.0 OUS VERIF) ALL DIMENSIONS AND CONDITIONS PRIOR TO PROCEEDING PROVIDE ERECTION BRACING AS NECESSARY UNTIL PERMANENT SUPPORT AND STIFFNESS ARE INSTALLED REFER TO ARCHITECTURAL PLANS FOR WALL OPENING, ARCHITECTURAL TREATMENT AND DIMENSIONS NOT SHOWN REFER TO MECHANICAL AND ELECTRICAL PLANS FOR SIZE AND LOCATION OF ALL OPENINGS FOP DUCTS PIPES CONDUITS, ETC., NOT SHOWN - ... • • �► S ABBREVIATIONS N t - l AB. ANCHOR BOL T AGGR AGGREGATE ALT. ALTERNATE APPROX APPROXIMATE ARCH ARCHITEC TURAL BD, BOARD BLDG. BUILDING BLK BLOCK BLK'G BLOCKING BM. BEAM BOT. BOTTOM BTWN. BETWEEN C. J. CONTROL JT. CLR. CLEAR C.M.0 CONCRETE MASONRY UNIT COL. COLUMN CONC. CONCRETE CONN. CONNECTION CONSTR. CONSTRUCTION CONT. CONTINUOUS DEG. DEGREE DET. /DTL. DETAIL DIAG. DIAGONAL DIA, 0 DIAMETER DN. DOWN DWG. DRAWING (E) EXISTING EA. EACH E. J. EXPANSION JOINT E.I.F.S. EXTERIOR INSULATION AND FINISH SYSTENA EL. ELEV. ELEVATION ELEV. ELEVATION EQ. EQUAL EQUIP. EQUIPMENT E.W. EACH WAY EXP. EXPANSION E XT, EXTERIOR F.D. FLOOR DRAIN FDN. FOUNDATION F. F. FINSH FLOOR FIN. FINISH FLR. FLOOR FND. FOUNDATION F.O.B. FACE OF BRICK F.Q.C. FACE OF CONCRETE F. S. FULL SIZE FT. FOOT OR FEET FTC. FOOTING FURR FURRING GA. GAUGE GALV GALVINI ZED GR, GRADE GYP. GYPSUM GYP. BD. GYPSUM BOARD NT HEIGHT HVAC . HEATIN' ;. VE': T!LATION AND AIR CONDITIONING I.D INSIDE DIAMETER INSUL INSULATION INT. INTERIOR JNT .JOINT JST. JOIST MAX MAXIMUM MFR MANUFACTURER MIN MINIMUM MISC. MISCELLANEOUS M.O. MASONRY OPENING; MTL. METAL NO. NUMBER N.T.S. NOT TO SCALE O.C. ON CENTER O.D. OUTSIDE DIAMETER OH. OVERHEAD OPG. OPENING OPP. OPPOSITE PCT. PRE -CAST P.L. PROPERTY LINE PLYWD. PLYWOOD R.D. ROOF DRAIN RE: REFER TO .. REINF. REINFORCED REQ'D. 'REQUIRED RM ROOM R. 0. ROUGH OPENING SCHED. SCHEDULE SECT. SECTION S. F. SQUARE FOOT SHT. SHEET SIM. SIMILAR SPEC. SPECIFICATION SO. OR (P SQUARE S.S. STAINLESS STEEL STAGG. STAGGERED STD. STANDARD STIFF STIFFENER STL. STEEL STRUC. STRUCTURAL TR TREAD T & B TOP AND BOTTOM T & G TONGUE & GROOVE THK. THICK T/ TOP OF TYP- TYPICAL U.N.O. UNLESS NOTED OTHERWISE VER VERIFY VERT. VERTICAL W/ WITH W/0 WM TH OU T q CENTERLINE R PLATE SHEET 1 N DEX SHEET SHEET CONTENTS REVISION � S1.0 STRUCTURAL NOTES S2.0 FOUNDATION PLAN AND DETAILS wrx li I ff OM NMT I01I001 �MI P @�/t0 rl S &Ucturj d Eggineering C'onsu/tants qp 66 w W x vi H O F-• 0 CA h 0 I N H a w z a z z u � o O Y � a � x W Ad A A 4 O N W N O fA oc M a � a �o� 0 a h N w < N b 3 N N I3a M li• v c O v ci c c 0 .9� i 2 0 0 m c. C v E D� O� IN rI 1. 1 N •� N'1 W 1-� A o O � > 3 0 Q a U � � W G� RECEIVED CITY of ruKwiLa PERMIT CENTER A 4 O N W N O fA oc M a � a �o� 0 a h N w < N b 3 N N I3a M li• v c O v ci c c 0 .9� i 2 0 0 m c. C v E D� O� IN rI 1. 1 N •� N'1 C > , v O SUBMITTAL SET ONLY NOT F04t CONSTRUCTION 11111M DRAW19 M ARE StMMK'T TO owvv5i!OIm SIG L C^L MIEVNR. 51.0 i �. . — -_\ -' �.� -�"'M ..q.11l��.� -»r► �. �. .. .,fin.. t c i r C c. c AWN a AL 3 C r. ��.- �r►� .1/�' •..+.w +U► r �.�r +11r r.. .. �. ^ .—. - �- ..���• "�.. -. _.�• r!!� -.� _ ... � •�� ,.r•�. m +r - ewe - .s —...- -_.+r SPEGAL NOTES: 1 Sl UYION" W1 �Y , OOE`; NOT ItI( ! I1Df THE 1A ►d1 T C ;UPP(_)RT 'I +! IP 1_)WN CONIF1' 2 U�; - �'• 1 (__)ACIN( OF TANK -ON T' N I ! EVE! S Sly., i BE M, :T, A. INE►IC "A TFD B) THE F011 ( iNK Al FN� ►JE FR r 10 laI i�,'R TI( -)!� 1 �I" LOA[ IN �,F:r�E�' T1 LIMIT !►li F F'E hlTlAl. SE 3 F + ?.IN. N HA` HLE N DESICNEG TO SUPPORT EA -_I4 TANS NTH CON 1 114' lIJS. E VF NL r DISTRIBUTED LOAD FROM I T ; t `UN IFN T5 TO THE TH; TA* TC THE EMPIE DI)FI Pl ATE AF i ITS PE i• IAII; � r 4 Cntr� JPV ()N THAT TANKS ARE MADE OF A MINIMI IkA ;f A36 STEEL SHAT i _' ;IVE I, TO AN DERSON - f t)N PRIOR Th F F' ^'CFEDiN ;. 5 Li.'AINN`� '- 1 ^J E'� " ESS OF THOSE INDIC ATFE) ON THE DE'tiWINGS H.4 ,J r; ' H? FN A COUNTED FOR. 6, CONS 1FY :­_L DIMENSION`> SHOWN C)N THE DRAWING'S `'FInR TO F n4PP!, A' 'I (JF MATERIALS AND O_ ICTION. 7. ANA DI'i FOUND IN THE STRUCTURAL DRAWIN6S FROM THE AC' 1 4 CONDITIONS SHALL BE REPORTED TO ANE)FRSON- PEYTON FOR RE : )N. 3/16" THICK TANK WALL, AY STEEL MINIMUM. 1, ?x4x2' -0" W/ (2) 1 k 7 8 "0'110" W S® 16" GA, TYP �.- EOUA.LLY SPACED AROUND 3, 16% MIN / PERIMETER. (2)- #4x4' -0" ® EA EMBED c� Z O O CA_ Ir a w w v cv I NATIVE COMPACTED EXISTING 4" SOILS S.O.G. 3 TANK ATTACHMENT & EMBED PLATE 16 ® 12 . 0 C. IN !'I /S DIRECTION i6 Q" 0. C. IN `W DIRECTION CLP ;TYP) - • • IN ;'51 DJRr ;- TJ � f lN E!K' DIPEC TION 1 - F'XIST'N+ NA�i J� SOIL �� " " rc �/ - �- SL4E, n 2SECTION AT N/S ENDS OF FOUNDATION :=a>c 111 C7 ti % 5 iPc "'q�N t SECTI TMU FJW EXISTING WA�.LS 13'0 TANK - PLAN SCALE: 1/4"=l'-o" :} 7/8'0x10" B's 0 16" GA, 81 LOCATIONS EMBED P! ATE Fp - TANK SCALE: 1 /4 " =1' - 0" R 1 /2),4 -0~ W/ (2) 7 /8 11 0x10 1, A.B 's 0 16" GA, (16) LOCATIONS - EMBED PLATE Fp I F0 TANK - PLAN i � 1 u C rr E� v FOUNDATION PLA 4 r TANK EDGF SCALE: 1/4 =1' -0" e z Q 60 TANK - PLAN TANK EDGE PER 3/S2.0 ® 6'0 TANK JOT SHOWN FOR LAYOUT ABOVE SUBMITTAL SET ONLY NOT FOR CONS LIC.'1 ION 1 o".r1%3 AM SIIIIJIIIIIIIIIIIIIXX7F TO rEoM 1AWAL �s r� ,r,�g Carisult�nrts _.� - _ - �. —. .-.r. .. �..... __�..' .w �1•. -!. � y.. .� � _ -�/r .. .. -.. ice, . 'Y r•. \r. .. � fir.. .�� �. 11u�•.II�..�. —� �.�_. _ � — „.�.�. - +.w�� •�. ..w -� s 7�. -.+rte •• ��. �.�le _ •.wea • . �, • "'M'#"!l�.f� -- I? 1 /`2x4x2' -0” W% f (2) 7/8 "0x10' A.B.'s ® 16" GA, (R) LOCATIONS EMBED �~ PLATE w w x H O H rA z O r 4 Q I h r. C 1 --I ~ Q z O L 0 z x CAI 4 r 0 r i i RECEIVED CITY OF T'JKMLA z J PERMIT CENTER � I i6 Q" 0. C. IN `W DIRECTION CLP ;TYP) - • • IN ;'51 DJRr ;- TJ � f lN E!K' DIPEC TION 1 - F'XIST'N+ NA�i J� SOIL �� " " rc �/ - �- SL4E, n 2SECTION AT N/S ENDS OF FOUNDATION :=a>c 111 C7 ti % 5 iPc "'q�N t SECTI TMU FJW EXISTING WA�.LS 13'0 TANK - PLAN SCALE: 1/4"=l'-o" :} 7/8'0x10" B's 0 16" GA, 81 LOCATIONS EMBED P! ATE Fp - TANK SCALE: 1 /4 " =1' - 0" R 1 /2),4 -0~ W/ (2) 7 /8 11 0x10 1, A.B 's 0 16" GA, (16) LOCATIONS - EMBED PLATE Fp I F0 TANK - PLAN i � 1 u C rr E� v FOUNDATION PLA 4 r TANK EDGF SCALE: 1/4 =1' -0" e z Q 60 TANK - PLAN TANK EDGE PER 3/S2.0 ® 6'0 TANK JOT SHOWN FOR LAYOUT ABOVE SUBMITTAL SET ONLY NOT FOR CONS LIC.'1 ION 1 o".r1%3 AM SIIIIJIIIIIIIIIIIIIXX7F TO rEoM 1AWAL �s r� ,r,�g Carisult�nrts _.� - _ - �. —. .-.r. .. �..... __�..' .w �1•. -!. � y.. .� � _ -�/r .. .. -.. ice, . 'Y r•. \r. .. � fir.. .�� �. 11u�•.II�..�. —� �.�_. _ � — „.�.�. - +.w�� •�. ..w -� s 7�. -.+rte •• ��. �.�le _ •.wea • . �, • "'M'#"!l�.f� -- I? 1 /`2x4x2' -0” W% f (2) 7/8 "0x10' A.B.'s ® 16" GA, (R) LOCATIONS EMBED �~ PLATE w w x H O H rA z O r 4 Q I w a� z O Q d 4 o� 0. z a x IZ W A a 7 N a� O oG W 6 w 0 0 N O� N �p O N v W .. W M 8 N1 � O� O a .. x � a � v w d 3 w d N d 3 a 0 N N Q ~ �O 'n c 0 0 y y V ti 0 � Op ti 0 c 0 V ;j < (�O) DDO rim h r. C 1 --I ~ Q z O L 0 z x CAI 4 0 4 RECEIVED CITY OF T'JKMLA z J PERMIT CENTER � w a� z O Q d 4 o� 0. z a x IZ W A a 7 N a� O oG W 6 w 0 0 N O� N �p O N v W .. W M 8 N1 � O� O a .. x � a � v w d 3 w d N d 3 a 0 N N Q ~ �O 'n c 0 0 y y V ti 0 � Op ti 0 c 0 V ;j < (�O) DDO rim w ,1. h r. C z J 1E-- � Ia err .10 w ,1.