Loading...
HomeMy WebLinkAboutPermit D2000-091 - KING COUNTY HOUSING AUTHORITY - PARITIONS, RESTROOM AND CUBICLESKING COUNTY HOUSING AUTHORITY D2000 -091 City of Tukwila Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 9818a DEVELOPMENT PERMIT WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES, APPLICANT IS PROCEEDING AT THEIR OWN RISK. Parcel No: 262304 -9123 Address: 600 ANDOVER PK W Suite No: Location: Category: AOFF Type: DEVPERM Zoning: TUC Const Type: V -N Occupancy: OFFICE Gas/Elec.: UBC: 1997 Units: 001 Fire Protection: SPRINKLERS Setbacks: North: .0 South: .0 East: .0 West: .0 Water: N/A Sewer: N/A Wetlands: Slopes: N Streams: Contractor License No: HOUSIT *215KD Permit No: Status: Issued: Expires: (206) 431 -a. D2000 -091 ISSUED 05/01/2000 10/28/2000 OCCUPANT KING COUNTY HOUSING AUTHORITY Phone: 600 ANDOVER PARK WEST, TUKWILA WA 98188 OWNER HOME ELECTRIC COMPANY Phone: (206)455 -1341 PO BOX 9, BELLEVUE WA 98009 CONTACT CLALIDE DACORSI Phone: 206 -433 -7360 15455 65th AVE S, TUKWILA WA 98188 CONTRACTOR HOUSING AUTHORITY /CTY /KING, TH 15455 65th AVE S, SEATTLE WA 98188 • k******* k***************************• k***************** ******* *:k*********k*k**** *** ** Permit Description: INTERIOR ALTERATION INCLUDING PARTITION DEMOLITION AND REPLACEMENT (1) NEW RESTROOM, AND OPEN OFFICE SPACE CUBICLE INSTALLATION k* kit** k*** k***•****•k•k• k*****• k** kk**• k* k* k*** k *•k ***•k** **k* *•k * * *k•kk•kkk*•k k***•k* *•k*kk**k*k* Construction Valuation: $ 500,000.00 PUBLIC WORKS PERMITS: *(Water Meter Permits Listed Separate) Eng. Appr: Curb Cut /Access /S•idewalk /CSS: .• Fire Loop Hydrant: No: Size(in): .00 Flood Control Zone: Hauling: Start Time: End Time: Land Altering: Cut: Fill: Landscape Irrigation: Moving. Oversized Load: Start Time: End Time: Sanitary Side Sewer: No: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Water Main Extension: Private: Public: * kk* k•k*****- k• k** kk** k** kk**• k**** k** k*kk k kk**k k** k kk** k** kkk* **k *kk * * * * ** *kk* TOTAL DEVELOPMENT PERMIT FEES: $ 5,340.19 • k* k* k**• k*******•k ***k *k* * * * *k * *•kk * * * * *k* ** * kk *k kk* k***•*** k *k * *kkk* :k *k * * * * � , k , * * Date : E i-02000 Q Permit Center Authorized Signature: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other state or local laws regulating construction or the perfor ce work. I am authorized to sign for and obtain this development Signature:_ Print Name: Date: 5/116 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. -.. z w r QQ LI J0 0 J CO LL w z � 1- 0 z 1- w uj co U 0 - 0 1- = 1- H IL O .z w = 0 1- z • CITY OF TUKWILA Address: 600 ANDOVER Pt; W Permit No: D2000• -091 Suite: Tenant: Status: ISSUED Type: DEVPER M Applied: 03/24/2000 Parcel #: 262304 --9123 Issued: 05 /01/2000 **• k •k•k ** *•k ****** * *•k•k•kk*•k•k ** *** k**** k**k k• k*****k k k l• * * *kk*k*k ***•k*•k•k *k *k *fr*** Permit Conditions: 1. No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. • 2. All permits, inspection records, and approved plans shall be available at the job site prior to the start of any con- struction, These .documents are to be maintained: and avail- able until ftnal inspection approval is granted, 3. Electrical : shall be obtained through the Washington State Division of Labor and Industries and all elect:rical work will be inspected by that agency (248-6630). 4. Plumbing permits shall be obtained through the Seattle -King County Department of Public Health. Plumbing will be inspected _:'by that agency, , including all gas piping • (2964722 ),' 5. All r`ntechani ca i work shall be under separate permit issued by City of Tukwila. _ `_"•" 6. Al ,ironstr.ucti on to , be. done in conformance with approved p l #axis and requ i rements of the Uniform B u i l d i n g Code (1997 as amended, .Uniform Mechanical Code (1997 Edition), arid;; Washington`. State Energy Code (1997 Edition) . 7. Val td i ty of Permit The issuance of a permit or approval of plans,. specifications, and computations shall not be con strued to be ° a permit ford or an approval of, any violation of, any •of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give : authority to violate or cancel the provisions of -this code,:. shall :be valid. 8. Any new ceiling grid and light fixture installation is required, to meet lateral bracing requirements for Seismic Zone 3: `' 9. Partition wails attached to ceiling grid "must be laterally braced if over eight. (8) feet in length. 10. There shall' be no .occupancy of the bui1ding(s) until the final inspection has been completed by the Tukwila Building Inspector. 11. VENTILATION IS REQUIRED FOR ALL NEW ROOMS AND SPACES OF NEW OR EXISTING BUILDINGS IN CONFORMANCE WITH THE UNIFORM BUILDING CODE AND THE WASHINGTON STATE VENTILATION AND _INDOOR AIR QUALITY CODE, CHAPTER 51 -13 WAC. z w QQ1 JU 0 w= H w g< a = w I- z � I-- O Z ~ O • - w L I O w U 0~ z Description of work to be done: I N - j - � jQ p 4L - g -j I j t CLUO 1 f ' sV-Tt ('I Qty D'i 'I -A Lt c t or-) 4 API PC tVt 'k t 0{ oftCe s c Cut ci (k SSW )t) Existing use: U Retail ❑ Restaurant ❑ Multi- family Warehouse El Hospital r:3 Church ❑ Manufacturing El Motel /Hotel Office ❑ School /College /University ❑ Other Proposed use: ❑ Retail ❑ Restaurant ❑ Multi- family ❑ Warehouse El Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel 10 Office ❑ School /College /University ❑ Other Will there be a change of use? ❑ yes .A no If yes, extent of change: (Attach additional sheet if necessary) Will there be rack storage? ❑ yes 0 no Existing fire protection features: ,I. sprinklers automatic fire alarm ❑ none ❑ other (specify) Building Square Feet: .R4 ilik existing Area of Construction: (sq. ft.) 151313b Will there be storage of flammable /combustible hazardous material in the building? ❑ yes 171 no Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets Project Name/Tenant: N Tm I cR '1, I ALTE - 0Q 0 -- K. G1-I -4 Value of Construction: It hoc oc: Site Address: / City State /Zip: Goo AN1)oVLK 664 W..C IUKUJILA Us1\cfilt °v Tax Frpel N t ber: ((Dp2 O'-/ - 9/2 3 Property Owner: r--1 C00.11\/ koUS1)^16 A u 'Moen)/ City State /Zip: T t&t I r Ulf 9R 1 �3 Phone: 1 ,- 2-4 -11 - 95D Fax #: 2x,, • 244 -- l Street Address: IS4- - C 6 / Sow Contractor: 1..C1-1- l� I Phone '�U� .244 - ` l �l� o Street Address: � , ►54 5- G3 i 1-h i JC. S OX City State /Zip: T 111,1 ALA-, 11111 i8P Fax #: ?2L 2'44 - 1 ,946 Architect: Si I TRASKIS LLC / s .S vt-s16 1.J ASSOcr s Pho e: x-26 - 8(4 - l c ¢;o Street Address: City State/Zip: 2363 t —n V -- Su ►Th 202 1< -UUr�- W,A o6� Fax #: 425. 885 - (208 in En eer: G L)sk t 1:t j �G �,� { 1 l.) Phone: 201. -1„22.- 332-1 Street Address: Gc S closi 1-v 6 . , &t►t 'k O City State /Zip: Saxiii -I 1 WA- etBio Fax #: /DC - i LZ - 58o4- Contact Person: , 14Lia DCiC -ors l C 1 Phone: It% - 1 1 - . 2 ) 13Coo Str et Address: City State /Zip: 154€ -5 l V r Scarf Tuv-w ILA-, W A -. 126 Fax #: 2CC ..- 342 - O r l 33 CITY OF TUrVILA Permit Center 6300 Southcenter Blvd., Suite 100, Tukwila, WA 98188 (206) 431 -3670 FOR STAFF USE ONLY Project NUmber: Permit Number: Commercial / Multi - Family Tenant Improvement / Alteration Permit Application Application and plans must be complete In order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. APPLICANT REQUEST. FOR PUBLIC : WORKS SITE/CIVIL.FLAN REVIEW; OF THE.FOLLOWIN •(Additional reviews maybe determined.by the. Public Works Department ❑ Channelization /Striping ❑ Curb cut/Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: Size(s): ❑ Land Altering 0 Cut cubic yds. 0 Fill cubic yds. ❑ Sanitary Side Sewer #: ❑ Sewer Main Extension ❑ Storm Drainage ❑ Street Use ❑ Water Main Extension ❑ Water Meter /Exempt #: Size(s): 0 Deduct ❑ Water Meter /Permanent # Size(s): ❑ Water Meter Temp # Size(s): Est. quantity: ❑ Miscellaneous ❑ Flood Control Zone ❑ Hauling ❑ Landscape Irrigation O Private 0 Public O Private 0 Public 0 Water Only gal Schedule: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Datsp =a ned: Da plicati n expires: 9 -ji4 21)00 Appllc ion t PLEASE SIGN BACK OF APPLICATION FORM CTPERMIT.DOC 1/29/97 Z ~ w —I C.) 0 to J 2w w 2 � w Z = w o U � O - OH w 2 O W Z U= 0 Z • I- wow limb 1 rem IMMIN think MI BUILDIN 0141 OR U RI Ell) GENT: 1 Signature � � U Date: 3/ 2 � Print c l� t,,.Q,,, Dc G5� j , �' ' �''/S` l -( 7 F 4. 5 01.33 ' . * Address _5 Avg, �L. City /State /Zip, j A l v/ A 9s 1138 ALL COMMERCIAUMULTI-FAlialY TENANT IMPROVEMENT/ALT11114TION PERMIT APPLICATIONS MUL` SUBMITTED WITH THE FOLL ING: ➢, ALL DRAWINGS 'TO BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT, . STRUCTURALENGINEER OR CIVIL ENGINEER • ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN • BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A SUBMITTED ❑ ❑ Complete Legal Description ❑ ❑ Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures (Form H -13). Business Declaration required (Form H -10). Four (4) sets of working drawings (five(5) sets for structural work), which include ❑ ❑ Site Plan (including existing fire hydrant location(s) 1. North arrow and scale 2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements 3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions 4. Location of driveways, parking, loading & service areas 5. Recycle collection location and area calculations (change of use only) 6. Location and screening of outdoor storage (change of use only) 7. Limits of clearing /grading with existing and proposed topography at 2' intervals extending 5' beyond property's boundaries 8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of use only) z 9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of those, identify by size and species which are to be removed and saved I-- w 10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change ct 2 of use only) D 11. Location and gross floor area of existing structure with dimensions and setback v O 12. Lowest finished floor elevation (if in flood control zone) • to 13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form H - W H 9 ). co u_ CI CI Floor o Floor plan: show location of tenant space with proposed use of each room labeled w • 0 ❑ ❑ Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of g Q any hazardous materials; dimensions of proposed tenant space. cn d ❑ ❑ Vicinity Map showing location of site I- _ z1.- ❑ ❑ Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack Z O layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of w rack. Structural calculations are required for rack storage eight feet and over. D • o El 0 Indicate proposed construction of tenant space or addition and walls being demolished U o ❑ ❑ Construction details w • w ❑ El Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of u_ O water supply to sprinkler vault with documentation from contractor stating supply line will meet or LLi z exceed sprinkler system design criteria as identified by the Fire Department. U El ~ ❑ Washington State Non - Residential Energy Code Data shall be noted on the construction drawings. z ❑ ❑ SEPA Checklist - if intensification of use (check with Planning Department for thresholds). ❑ ❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other land use or SEPA decisions. ❑ ❑ Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County Department of Public Health prior to submitting for building permit application. The Department of Public Health is located at 201 Smith Tower, Seattle, WA or call (206) 296 -4787. (Form H -5) ❑ El Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no contractor has been selected at time of application a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed . . by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application, and obtain the permit will be required as part of this submittal I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. CTPERMIT.DOC 1/29/97 s f i, r i,,iv ;4 :4* * * * ** * * *:4 *A ** CITY . OF TUKWILA, .. 'k3 * * *3+ * * *:4 * *** *:4 TRANSMIT Number: Payment Method: Permit NO3 Par e1 No: Site Addr'es :This .P.aynieht Accoutl.li .Code 000/22,100 0001286.904 \r �:.�,: yj. •3'�`r�.'i1.�S ilii''1;'i�.jl: ::j'�;.J ±}t. J >, }° :4 * **A A44 * * * *•k* NA 2000- O * *i4 * * �t. * *:s . k'I * *A* 8980022 (iic un CHECK tlt.tatio 02000- 091 Typ 262204-9122 600 ANDOVER PK W 23S.�2; Description BUILDING - HCMPES STATE i3UFL'3 ?IWG SURCHARGE •h * * * **:lk•A4 A *.k*3*3 :•. *A:5 **3:* *kid. * ** 777777 777777. TRANSMIT * .A1‘4: i•3••. * * *:4 * * t4 *ilc *•A *: a*:4 *3. 1- , 23 . 2E, 05/01/00 15:23 rl: HOUSING t1UTfl WER e; D'c :vPEnM DEVELO MCAT 'PERM) : T Total Fees: 5,340.19 Total ALL Pmts; 5,240.19 Balance: .00 * *•h'E* ** k** * * *sl3 *7%.*ik** *** * *f :*** ::l k k**4tk{ : *A **•* :3. * *•k *3.*3.**3. *•k *:k *•..3 Amount :3,2:33.75 4.50 3960 05/03 9717 TOTAL 3238.25 . *********************************** *f; * * * * ** * * * * * * * * * * * * * * * * * * * CITY OF. TUKWILA, WA * -O9 I TRANSMIT * * * * * * * * * * * * * * * * * * * * ** ********* * * ** * * * * * * * * * * * * * * * * * * * * * * * * * ** TRANSMIT Number: R9800256 Amount: 2,101.94 03/24/00 13:58 Payment Method: CHECK Notation: KCHA Init: WER Permit No: D2000 -091 Type: DEVPERM DEVELOPMENT PERMIT Parcel No: 262304 -9123 Site Address: 600 ANDOVER PK W Total Fees: 5,340.19 This Payment 2,101.94 Total ALL Pmts: 2,101.94 Balance: 3,238.25 ********************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Account Code Description Amount 000/345.830 PLAN CHECK - NONRES 2,101.94 2374 03/27 9719 TOTAL 2101.94 Z g Z ~ w. 00 y 0 cow J L: w 0 g a P_ d , 1— 11 Z � F— 0 Z w D C.) co 0 H ILI 2V U. w • Z 0 — 0 /- Z . % Pro ect: Ty se ofInspecti. • / A, dress: 4t401410 40 ir, 17..4 Date called: eopjhje7.-opHile Special instructions: Date wanted: `'' Requester: Phone: INSPECTION NO. Approved per applicable codes. COMMENTS: Inspector INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 • 9 PERMIT NO. (206)431 -3670 Corrections required prior to approval. r• Date: r 0 $47 6 REINSPECTIO F E REQUI ED. Prior to inspection, fee must be paid ,-at 6300 Southcenter BI ., Suite 100. Call to schedule reinspection. Receipt No: Date: r COMMENTS: 4 !/ 2 y'? B?://(va rhi7fii . 2,)Ro) � m ri,63 -)-1,— /O2 / ., ./"...",4 Add ess: e O ,�,ri�dbrz /".:2 GJ � rr'� v r'.eii� ` � /9.P.. 3)1 r,ct f" ti 5+s "Dor)" 2.4 / 440 c A le /1h /Y! SS he,4y, /.//1, re—r2 te...v/ /.d t '..- • r`7 6 •• r1/1/ 6464 ._ /J 41-1-7, �! 20,f ` m/,/0i,7 fr-./, -I aWie/ 2.07 ,4, I // ,Gprsrr .5) /vd -h 4a 7 1 s/i c�s6a, 2.€92... 4.-- / r,►r7,lr,�./. / emu �, .c �wu -e 1/ / - 4, r r� oar /7a Yt�d�-tlie). -1 G/h/W.#1 ! h / 4 b / ! ,,,, , lx,I-h,44 ,.. y+ ✓,"CJ d i61/ C14 Pro ct: Type of Inspectio . Add ess: e O ,�,ri�dbrz /".:2 GJ Date called: D/ Special instructions: _ • gL, � "' Date wanted: /— 9 - Requester: Phone: o4' S'7Y --/,, 243 Inspector: kLn INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 ED Approved per applicable codes. Corrections required prior to approval. :r�7, v-, /0 E] $47.00 REINSPECTION FEE REQUIRED. Prior fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: i•'ta T 7' =Yr� Date: PERMIT NO. (206)431 -3670 rgr`e.. �1 ... ?��ai.9iiil:tn:�i`w'17. Y: Z: ?' , J4•��'i'.',�'.:tii2.:. >�:S:T:? 1 +Sc' COMMENTS: Type of I ection: Frx_r 06e e./�t9� y Address: AP `_+ ` / 9 47- , GL. ,, ,e7 % e /iS S, , Date wa ed 8 is/op D (1:9,-,v/967x ,fix r 7 �i'6A// Rp ster: � Ti (C //4 I (T /GG v /At /.L' 77 r 7 Pe: A.G- v/ i„'0,` J f " e //L CZ7c9 t / i Project: i idb 000/U TV Type of I ection: Frx_r Address: AP `_+ ` Date ` cal d: Special instructions: Date wa ed 8 is/op a.m. p.m. Rp ster: � Ti (C //4 Pe: •■ E-E- INSPECTION RECORD R etain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 9818 PERMIT NO. (206)431 -3670 Approved per applicable codes. corrections required prior to approval. Inspec : Datt /�C) ■ $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: 6�.. +w..wRw ^.:.rte .u:l + +, �w:i:Y� •'a'�:.�r's4kv" •• "� �' « ` dw a: i�tr. a'sLLaid�4..'1±.737�ii`�"l�:.y(" vale: i +lalkl.�"vG'3fw.wr.'L`eN..' Pry ' Ml' (1W „may. � % � Type �ivd y� �rL A .. i p • , 4 J ) Date called: Special instructions: Date w tec �� a.m. P.m. Requ /47X-(6444- C Pho c5_. 7.7 INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 Approved per applicable codes. PERMIT NO. (206)431 -3670 COMMENTS: OW.4141 Peeeir /fril�I28vRC 06a./A4 C1) 4 41 :4 - fil AfP6-6 T p T . SA GS p (f -t. , .(`ci Sc ,y. wruri... orrections required prior to approval. $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: (1 9 'et• • +: c: teH. tis;:: st„` d< A::,t;? edry."r ...''r':.lr?n;ir•:v;,.:rc1'::..s Z W re f UQ W i N WO 2 g a D. a . 1- Lu I— O W es. D I- W W I — u' O. . Z W z Prp�ect: �� / Co�/.✓>y HuvS✓.c Type of Inspection: 5.1 p CE /G ,6 d dr�es�s: 1W Date called: Special instructions: Date w Re ester: Mig(C/fj /Weil/fir Phone: INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 (206)431 - 3670 n Approved per applicable codes. ,Corrections required prior to approval. COMMENTS: of A,d6.6,72ed A /4.74/ �� 6 r; ��, • ,¢.�� „� Insp r: Date: ( /6�� $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: z re w 00 co 0 co wO � N 3 � z� w U O tn, (31— tu W H .. z U= O ~ Z COMMENTS: ,/ "IC , q c6 s7 =e J �,L( 7 1 ' a, 147`.0 , neoss \',7°- r" 4,- sec 77 o. 0�t' 7 711,11 Gt.),e04-ror 61 49/5 /Y 7 G /C7ti7 4L ,416 c4'.Zt 5 a.m. ' p.m. PEcrt> (7�..*4-1 40:77%17g-4. r77,-A - /r—r ( 6,te c > lt `ST le-Z i Project: .-, nc ' , /( • Type of Inspection: (l)VO / Address:) , / :c c dnrraV/YIk.! *) Date Z Iletl: Special instructions: — Date wanted: ` - I a.m. ' p.m. Request t _-mot. v_e.,_. Ellgl INSPECTION RECORD Retain a copy with permit INSPECTION NO, 1 / CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 PERMIT NO. (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. Dar , 7: E] $47.00 REINSPECTION FEE REQUIRED. Prior to inspec ion, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Insp r Receipt No: Date: I r:,.�.ni:� ` �r L r keielVd. Z W O 0 o W J i w LL W � Q = d H W Z � W I . ui U � O 5 . 0 1- = c y I— LI- -O W Z v w F. O ~ z COMMENTS: R6- c/f -r1 OL ,Co ',-, -r PC .`I S Tic /,c.6c1C 47•►at, K,er ,c;e _e -oto,- r-, Rom 7)/E, C9 76,/979 l/itri o,2.,-t Pac.ogiVCD r S /7 /S ftro�:a 71/.4T 74/$ . 4 47o4 t e. o-14-e-, ,< rOT Se LF r - Ex 1 tii,? ,lo et 2-4 so r,r / 7 '6-6 ci A 7 0141 ,d. if: ( 6/-tise /14 v5T fE /,</) c 64 Y/ . /u ,ee ,;‘, f o , ,,f 4.t1 //Li- gAt.6 iga22 f4 fitrc7 WOv4n /QvieC" Z Svq,, )eT rift Gw,o, 771/5 i t// fe-itr7 ASe'° ,:. P,z,rtcr, 4. OL' <o,4.rt, Pt..s1.5rres /s s.,nnu.ak ,(t,( CuI ur44 Pr ' t: ,t.rt7 6 (AL, 11 / 4 "/- 5 ."‘" Type ofI v ) S,s •*---c1O44) 06 r e /' Address: 6o0 Ai P ex} Date called: Special instructions: P3R70, ftriST7Cr /,urtj4j OA .1 g t)I t-D,ti27 rt K type Ai/ 10,,J/ Cg.g //t7 s�•4i Date wanted: a.m. p.m. Re nester: �A r �-rc �� Phone .5''5 ✓'/ INSPECTION NO. El Approved per applicable codes. INSPECTIO Retain a copy h permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 PERMIT NO. (206)431 -3670 C orrections required prior to approval. n $47.00 REINSPECTION FEE REQUIRED.'' Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date? • Receipt No: Date: BC z w r -0 0 CO 0 111 � LL w 2 d � z � o . w ~ w C.) o - 0 I— w I � Uo iii z U= 0 I— z 1ri�ai. 7�i�? 3'` �:.. 1i;t �' ,.S� .''�''� �:S7�ttn��;fs�:rtr/K �xi� '..itASl;f,?. �' '�"'"�ii. 4.�:� � �`a�. COMMENTS: pe.. V/6641 7) (b 06- ,2 4'J' ,eE.rtir,f-fc °Ps - pgv v s C Address: Special instructions: Date wanted: a.m. P.m. Requester: Phone: M Project: Typ of Inspec�tioi: 5 vsPt/1?+% Date called: e lt,/ Address: Special instructions: Date wanted: a.m. P.m. Requester: Phone: INSPECTIOECORD Retain a copylwith permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 981880 (206)431 -3670 0 Approved per applicable codes. Corrections required prior to approval. Inspector: Date: El $47.00 REINSPECTION FEE REQUIRED. Prior to, inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to scheltale reinspection. Receipt No: Date: COMMENTS: eve' ,9 rTie Y - �2 4" 13 -r 471.-r 0 56 c n o-,Lr /.313 414- r7f6 Ar,45N TU,L( 5j4 G ,crF 6c/ CoOE - Di JP Afar ,t..ro 7 4 I/4474. � -DF ( /.+✓c " S r/ B.fi/7TA6 At. /, -/i, 17,677 .0 f?os 6-1) /41-- .€E >7�.vr�. , 7vs7' 1 _7` «rn S. -,-1.4 )Q-02(//,e-6-1 Phon 3; '7a / A Project: KK1'— (6 Cm £,�.(r — y Tye of Inspection: 5 ' 1-dirtv c ie4.(.6 Address: " t Date called: Special instructions: Date win y �/� 1 0© a.n p.m. Requester: / Ct4 Phon 3; '7a / Approved per applicable codes. INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 9818 PERMIT NO. ".�i.'y' C,�.GC�r:;Ga7 -,-t— _ _. - • _- '.a6a -.n t i.' z.i r` - ..:..a�.:..•'"",.n .c;.nCR:,ri:�:sa�..'... ,.I <a. �:;t 1- (206)431 -3670 Corrections required prior to approval. Date : 9 $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: z J U 00 W = CO u_ W u.. ( P.. �.w z �. I— O Z L U U � o I- ww O Z p NOTICE: IF THE DOCUMENT IN THIS FRAME IS LESS CLEAR THAN THIS NOTICE IT IS DUE TO THE QUALITY OF THE DOCUMENT. COMMENTS: f P 6-a/6 c4/46s t c ,,aer. / • Pled.kfr 0t' (a1 C. rn wS , SOT 4V,4cc. t.I - ( l f )'7 Pt-bm f ?ri' PLUS 0 Special instructions: Date wanted: a.m. p.m. Requejer: Phone: A 7/iL ct: ( - •Tipe o e Zn: /�� & aL.G ao 4 lotJ Date called: Special instructions: Date wanted: a.m. p.m. Requejer: Phone: INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southceh \er Blvd, #100, Tukwila,.1(VA 9818 PERMIT NO. (206)431 -3670 Approved per applicable codes. LI Corrections required prior to approval. $47.00 REINSPECTION FEE REQUI • ED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Insp Receipt No: Date: '.` ��' ac: �`.. rt:." s�. G' w�x�rr, "`w.;�" s �`..[- acF' �`... i.'' tl+;r''R:a:i�v:�s::'s,:s':�+%; .,• o. �' y���t +aic"aan:ri�..�:i•Ctik.l�.l:na� ......,; Z W et 6 .�U 00 N O WW J t0 LL : W II . oD- O I-- W W II ~. - o I z O ff' Z Project: : i r , ,.. ( 14.,( -,1,, �, //�r/4 Type of Inspection: -F-e_r , '1 ,:i. , I: �{= , - a : � ; r Coo f Address:, / .) %O . '4,2-7 1 6,46/ - '. r L / =*� `,i Qa a called: I - 1\ • Co Special instructions: r.' .. ' "; l•i..0 k)(1 I / ( . Date wanted: a..m R 'Oct V C__ Phone: 2 0 el, 12 s , %,,.-/-)6) INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 PERMIT NO. (206)431 -3670 Approved per applicable codes. ❑ Coru ctions required prior to approval. COMMENTS: S T- f � . (k)pF 7g-t-/ e/(6 El $47.00 REINSPECTION FEE REQUIRED. Prior to inspec ion, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: i�t�. tier w' �a4� ` c�.`,�ei'ilrut"a1t21��Y�:t1�f€: ��^'�} o�:tiµ : �` di�a�i4' L:, i? �; nS' ia�tiht':: L^.` ��t,' r` u' �+ ' .5!tul.^,Y'Gx'r'�i�!✓,:i�':r.�a , `' z W re 00 co o I J � WO J u. co W z F zO UJ W U� O rA, OH W W H H u_ O .z 1 O z COMMENTS: Type o t YP 1 CS/t.,4 /77 (7 /CAA ..-, : Date called: d1 � tlo - .�' � �K",OSE j C ' u-/77i a.m. p.m. Reque /e Phone: (t7c 64..10, ,4 -°G 66,...0 /7 /.2 )ft-(57 g' )2 AG _./ A / f Pro ec ,, / 1 "W -a 4,<_1,,t, Type o t YP AZrr : w Date called: Special instructions: Date wante 7 / (0 40 a.m. p.m. Reque /e Phone: 431 INSPECTION RD Retain a copy with perm INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila; WA 981 Z W re 2 00 0 W F- � LL W O QQ = d. W Z � ZI- wW 0 O -' 0 I- w u.l I U O wZ U ( o H O z COMMENTS: Type of Inspection: tr`'1 Wck.i t \ oLtEkncl Address. (ocZ (rn&o.e4 P K h) f .e../.4 An-c?-az Special instructions: Date wanted: CG,: e.4 /,-" 6 . c 4e .c., fc•- ' p1t9/361/4/1 /C:7 ,e9t ? Phone: 2.C6-- 16)3 -- 111to a e�.6 - : g '. I (/.,( ,, L4c 6-6 ( 6icic4TZ,G Project: KInc CU.. 1- )ostrq Type of Inspection: tr`'1 Wck.i t \ oLtEkncl Address. (ocZ (rn&o.e4 P K h) Date cal called: - 1 --1 - c0 Special instructions: Date wanted: p �� Requester: Phone: 2.C6-- 16)3 -- 111to INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 a . Approved . per applicable codes. ,. Corrections required prior to approval. INSPECTION RECORD Retain a copy with permit Insp= o i Date ? / $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: zw74,01 is• AS PERMIT NO. (206)431 -3670 �i�M: i? �'. a7�" ���« �ii3s2DLs:.i.�:Ya�u"`x�lm:a fii"r� tie, �.�5?'t'=^k�: _^: .:ri`•':'.- :- ,:�::��.::,':�:...: �::a3'icfn•i :.`...i� c.,:�:"i,�.wiC:i;', +iY,'.:ES `.+ , " Z W 00 co W W J H W }} • O g J . W co d I- _ Z F H Z H. 0 I - = w I— - • 0 .. z 0— 0 H O Z Prot ..t) m 6 0ouiLtrzi T of Ins t' 6.-- AddrG n p , l Date called: c .-4 04 Special instructions: Date want, �� � e) a.m. p.m. Reque11/�� Phone: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 9818 Approved per applicable codes. INSPECTION RECORD Retain a copy with permit PERMIT NO. (206)431 -3670 Corrections required prior to approval. COMMENTS: ittO �� ic7�77c � icr � E�c?.�U�ft seq. 1: Insp n $47.00 REINSPECTION FEE REQUIRED. Prior to ins ection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: Z I-- qq = J U 0 W1- Nu_ W 0 u _ = d I -W z � 1- 0 z t- Lu 0 O O N 0 I— W I0 IL. .Z = O z .; . r ,i;'ii:±P ;,::a °>•:L'lt�d'h'.:f : h4.:^ i' i«. isi:: �.4:�afi+itatSlt�+�GF1. � .�oS}tt�osriY,i�'f%!�d'6'i+�'� 's ldr►` t'i �rk '?q"e COMMENTS: `V rittfl, • il/-/ Aft 1 SYVPS .I 7 --- � l7D012, Fe-.4744k-S .9 -a X 1'7' 56cc,4Z .. 7t) `t e44 (75 Date called: Cr - 3n ) Off= ,9 1E nr S EE Pl v? &/ S ,<JoT- , Re uester: z. Vt..... Phone: ..<. I - r r- .)' - 0.- C ? ( ) Project: (10' I F'(( ■ A \6.„.i., i I , \',\ i...( 4rd.J',,e.cs t /Type of Inspection: 'I.." •- • 'i'; , (6 Address: I . G (0 A Y1,4ev ,r y 4 UJ. Date called: Cr - 3n ) Special instructions: Date wanted: - 7 -- '-> ' C �'. C.) a.m. p.m. Re uester: z. Vt..... Phone: ..<. I - r r- .)' - 0.- C ? ( ) INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 . rte- _ __ -- ,Ym e}. mems �C.tifl._r orrote '] ry�f yy�� ttivg, PERMIT NO. (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. r-D n $47.00 REINSPECTION FEE REQUIRE . Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Ins Dater. o) Receipt No: Date: 'S:?+. �[ Lr�''+ aiM: t�f:. F• wwubtiwS. f�1F4oil iyY .MMyp�M2d�.bw�+M�s�l' - N:" "�k� COMMENTS: /. /�� 19T ,l Z 0 /z s pr /6.- 51 t, / QC- -24 4c //( ISM (-6 ) p u; X t- ,Z- 3L -c/ Z6 (0' oC it�'i,�c) e) C6-01,4'r 6 57 -t. /7 7 e /,/57)4 *,1.4. 5,0i.5 £ / vo c--- ,1,K Reques er: /»'Z i2ic `1D ('iV/.3 07t(6 57 O P hone: / , / / �G' Pro � jf�' ct: ;;, ' / ;' /' .') Ty ee of Inspection: Address' � / ` , /(` ') ;= it / 'YP'r 7 /J( �7 Date called: lf `, 9 - f r S pe ial instructions: ( 2, 1 / / I ,e_ ` 1r.G.. .7 L."/ _ V-e_ , 2 5 - l ' U Date wanted: _ (''' .c--.) C 1> a.m. p.m. Reques er: /»'Z P hone: / , / / �G' INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 9818 (206)431 -3670 n Approved per applicable codes. Q Corrections required prior to approval. In: $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: G: a:..' 1N �' • 1 w�' ::::..':s4i:..i�x:,inC ""' i1..- h".:. is .'�x�...i'e:�'u�:i:+l.:^'<'m.: T ..G+ii d �C"i�Y:i..s::ti: e�' ° 1:xY�:dn:+..:•,n'ly :iY•4i� �s Mkt' t> •�' possandamememangrammte.rxv- z' 15 "1t ,9 Vs':w:Y•�'.:.j • Project Name Y1 (J Address __Retain current inspec.tion_schedule.. Needs shift inspection Approved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre - Fire: Permits: Authorized Signature INALAPP.FRM City of Tukwila Fire Department \N :-t7.) TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Rev. 2/19/98 Steven M. Mullet, Mayor Thomas P. Keefe, Fire Chief Permit No. O "'1 Suite # ak Date T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206-575-4404 • Fax: 206 -575 -4439 z w 6 JU 0 U 0 w J = N w Q � LL I- ILI Z = Z o U 0 OH w L O Li l Z U H 1 . O z September 17, 2001 Mr. Claude Dacorsi 15455 65th Avenue South Tukwila, WA 98188 RE: Permit Status D2000 -091 600 Andover Park West Dear Mr. Dacorsi: In reviewing our current permit files, it appears that your permit for interior alteration including partition demolition and replacement of I new restroom and open office space cubicle installation, issued on May I, 2000, has not received a final inspection by the City of Tukwila Building Division as of the date of this letter. Per the Uniform Building Code and /or Uniform Mechanical Code, every permit issued by the building official under the provision of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time for a period of 180 days, after the work is commenced. Based on the above, if the final inspection is not called for within ten (10) business days from the date of this letter, the Permit Center will close your file and the work completed to date will be considered non- complying and not in conformance with the Uniform Building Code and /or Mechanical Code. Please contact the Permit Center at (206) 431 -3670 if you wish to schedule a final inspection. Thank you for your cooperation in this matter. Sincerely, Ste fania Spencer Permit Technician City of Tukwila la�crl e — Xc: Permit File No. 1)2000 -091 Duane Griffin, Building Official Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite 11100 • '/Tukwila, Washington 98/88 • Phone: 206-431-3670 • Fax: 206-431-3665 z W ` 6 o O rn W W. J co IL W0 g- ti Q: 1=— _ Z F— 0 Z W U 0 O N C3 l— W W! 2 u ' 0 ltl Z U= O ~' Z • • Department of Community Development . 6300 Southcenter 81, #100 Tukwila, WA 98188 Phone: 206 -431 -3670 Fax 206-431 -3665 To: Fax: Phone: /4 7 A"e/M 2104, i74 `439 Re: 4?)1da ' 9/ •Comments: s. From: Pages: o7 7 r- .r • Date: /D =0/ ❑ Urgent ❑ Far Review ❑ Please Comment Q Please Reply ❑ Please Recycle ��!>ke/LG. -6; / z I C4 1 J 0 00 (0 0 CO ILI J H WO Q u. 92 0 = _ z �. I- O z ,- W ui U O� 0 I - . W I W O ; ill Z , 0 - H = O 1- z COMMENTS: Type of lapection: k r4.(r—u� Address: Date Special instructions: Date wa tedy A9,7,5 / i'ib a.m . p.m. 4 7 A« ,2,17o /-1S - 1-1,&- �C ' ,&.‘• 7 . -ci .5 - _ %,c. r r /4":. ' /Al '- r_ % - 7 r7 c t/ / L t- ) . /iL � cT-76-7c 7 ,e' r _ J Proj ct: i'S1 kJ&i ('of,k.! i (-/ Type of lapection: k r4.(r—u� Address: Date Special instructions: Date wa tedy A9,7,5 / i'ib a.m . p.m. Reqgu P47 Zrf 1,4 Phone: n b 0 INSPECT, J RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 9818 PERMIT NO. (206)431 -3670 0 Approved per applicable codes.Lorrections required prior to approval. El $4 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: , ' r •••• TRANSMISSION RESULT REPORT (OCT 05 '01 03 :59PM) TUKWILA DCD /PW THE FOLLOWING FILE(S) ERASED FILE FILE TYPE OPTION TEL NO. 037 TRANSMISSION 9 *- 2065741234 i (AU PAGE RESULT 02 OK ERRORS 1) HANG UP OR LINE FAIL 2) BUSY 3) NO ANSWER 4) NO FACSIMILE CONNECTION ...... --- ... �;(': CL W a. 00. N0 . NW W O Q 2 1 • Q d � I- O� Z H, al la D p. O 0 0 1- = U '. I- - O LU 0 - . 17. H O Z 06%30/2000 15:58 20693802 MIKE WERLECH CONST To: kAY �. From: Mike Werlech Construction, Inc. 4522 49th Avenue SW Seattle WA 98116 Phone 206-937-2208 6 kn." so 13 Doe nj b lA /Va. FAX TRANSMITTAL Fax No. 206-938-0227 Date: 30- - oqv Notes: /� c u r•! T y 40 VS , #.1 C; Number of Pages, including cover sheet: ■ A- v714a2( 'rY 7 . 3 e. A . 7 6 0 0 A +J O It, t Ric #3 0 A RECEIVErl JUL 0 COMMUNITY DEVELOPMENT 1 /14.sr t)6c- r d12 S'f%tas R c a5 0- c. / Ss 4 o Y n/c, o • t4 S , r./ s PAGE 01 W . rt U 00 0 W = . J i- WO g Q : I- W I-0 Z O 0 H X 0 W W W H -O ui Z , U - . 0'- 0 Z 06 %30/2000 15:58 2069380227 APR -24 -00 MON 03'= ; KCHA PURCHASING DOREEN CATO.:'! :. RICK S. 8ENDr:14. rigs 4 . '• DE35.A COATL• S S1TARON MAC'= ALVA SAD1.1- STEPHEN J. NORM:`. 2) Q. Erx midi) c Direcrrr April 24, 2000. Additional Tnfarmation Answers and cl3rii A. Bid Due Date remains April 27, 2000. Q. Steel Stud-• is 24 inch O.C. acceptable? A. Yes MIKE WERLECH CONST ADDEN NO. 5 - Carpent FAX NO. 206 242 0733 KING COUNTY HOUSING AUTHORITY PAGE 02 P. 02 This addendum iS used to clarify, change, delete, add to or substitute items in the original bid documents. Reference Paragraph K. 'Substitution for Specified Products' of Bidding Instructions: Delete:...... any request for substitution of specified products from the bidders or suppliers : .ist be received by the Housing Authority not less than five (5) calendar days befer ;: Cr.?. ,..:ate of bid opening 1) Q. Acoustics? Ceiling: Do you want shadow molding for the main areas repl :iced or use standard :1'l angle? A. Use standar; wall angle. Aeouaticai Ce ling: 95112,1.A.1 calls for exterior grid. Is that correct for the interior of the huilchii , It is more expensive. Use ini,f1 •01 arid. z w re U O. Co J H, W O 2 uQ to = CJ. W F- O` Z !— W W Ufn O -. • W w - U Z U O •Z - 06/30/2000 15:58 2069380227 APR -24 -00 MON 02 KCHA PURCHASING Page 2 Addendum ;.:5 April 24, 20rc 4) Q. Dox;n in an arca in first floor conference room for projection screen? A. No, t' ;one by owner at time of screen installation. 5) Q. Clari!f: Floor Plan Keynotes 4 and 5 on page A2.2. A. KO- TA :vi l' perform the work in Keynotes 4 and 5 on page A2.2. 6) Q. Clarify demolition, particularly any and or all, as noted on the Demolition Plan page A2.1 A. Particularly Keynote 8 and it is suggested at one day's work time be allowed to cover any ir�cid�nt,�i demolition that may be encountered in the normal course of Tenant 7) Q. A. Clani ry the size of the fire shutter? Contractor will furnish the lire shutter. See note on A3.1 - 'As per opening'. See drawing A2.1- section attached: The opening is indicated (open since Owner demolition of demountable partitions) and is approximately 6'. 8) Q. Clari fy Not A2.2 note 6. A. Mechon = cal contractor will install lavatory, shower and faucets. If you have an' ct:'st please do not hesitate to call me at 206- 433 -7391. Sincerely. L'GClr� /Il�l_� Patricia Largest. Assistant Enc. Drawing :\. ; :•ction for Fire Shutter END OF ADDENDUM #5 MIKE WERLECH CONST FAX NO. 206 *e42 0733 PAGE 03 P. 03 z w CC iJ 0 CO 0 CO ILI' Ui _ LL; WW 0. LL -J = a: z = z 0_ . . 2 n •U0 o - .. 0 H W W' Z . t-- U- O .z w ui •O z APR -17 -00 MON 07:44 AM KCHA PURCHASING BUILDING DIVISION REVIEW Date: Project Name: Application #: Plan Reviewer: End I initial review. FAX NO. 206 242 0733 Tukwila Building Division 6300 Southcenter Blvd. Tukwila, WA 98188 206 / 431 -3670 April 11, 2000 KING COUNTY HOUSING AUTHORITY D2000 -091 BOB BENEDICT° Conference room 109 must be provided with not less than two exits, exit- access doorways or combination thereof. Note: One may provide egress through an adjoining room and the other must lead directly to the exterior or to a corridor. 2. The second floor hallway(s) designated #202, 203, 209 and 215 comprises the egress route to the two required exits from the second floor. Consequently, the hallway layout must exclude " dead ends" greater than 20 -feet Re: UB + Section 1004.2.6. ac door i h GOrrrl P. 02 z z w � U O 0 N 0 . w= J • L. w °. U-a D. a. I- w zF 1- 0 z I- uj U 0 -' 0 F—. W W z 1-_ 0~ z Project name /4 6h C k 140 H, A ,o Address Description of work I _ _. . Related reference number The above project permit applicant, due to the limited scope of work is authorized to submit reduced plan requirements describe as noted below. 2. Minimum plan and /or specification requirement: l k Site plan Floor plan Elevations Foundation Cross sections Roof plan W.S.E.C. compliance Narrative Structural calculations ( stamped by Washington State licensed engineer ) Specific required information 3. Other special instructions: crrtGc_�r p K 2 cop% _%r rcvt5ed 64 koi \e--cbt Authorization by, TBD3/96 -f3 ; Application # t) 2 c) —01i ALTERNATE PLAN SUBMITTAL AUTHORIZATION FOR LIMITED SCOPE OF WORK U.B.C. Section 106.3.2 exception Complete permit application required: ( Note, all application must include; 1) property assessor number, 2) copy of contractors license or completed owner waiver form. ) Building Mechanical Other "' , Tukwila Building Division (206)431 -3670 A 7.2 Date a fte t e a te sued ( Authorization void 3 0 days date ) z 1 Z e � J U 0 J = F- . LL w u. _co D w H =. Z �. Z o w w U� O 22 w I, u. O . .. z W U = . P O.~ z April 14, 2000 Claude DaCorsi King County Housing Authority 15455 65 Avenue South Tukwila, WA 98188 Dear Mr. DaCorsi: SUB ECT: CORRECTION LETTER #1 Development Permit Application Number D2000 -091 King County Housing Authority 600 Andover Pk W This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed review comments from the Building Department. At this time the Planning Department, Fire Department and Public Works Department have no comments regarding your application for permit. The City requires that four (4) complete sets of revised plans be resubmitted with the appropriate revision block. If your review does not require revised plans but requires additional reports or other documentation, please submit four (4) copies of each document. In order to better expedite your resubmittal a Revision Sheet must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions please contact me at the City of Tukwila Permit Center at (206) 431- 3671. Sincerely, Tammy Beck Permit Technician Enclosures File: D2000 -082 City of Tukwila Department of Community Development Steve Lancaster, Director 130gidr- 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 -431 -3670 • Fax: 206-431-3665 Steven M Mullet, Mayor z z re 2 J U 00 . N 0 w= ("U ° LLQ co d = . O w o O N 0E- ww .z - I o '' z BUILDING DIVISION REVIEW Date: April 11, 2000 Project Name: KING COUNTY HOUSING AUTHORITY Application #: D2000 -091 Plan Reviewer: BOB BENEDICTO 1. Conference room 109 must be provided with not less than two exits, exit - access doorways or combination thereof. Note: One may provide egress through an adjoining room and the other must lead directly to the exterior or to a corridor. 2. The second floor hallway(s) designated #202, 203, 209 and 215 comprises the egress route to the two required exits from the second floor. Consequently, the hallway layout must exclude " dead ends" greater than 20 -feet. Re: UBC Section 1004.2.6. End / initial review. • Page 1 Tukwila Building Division 6300 Southcenter Blvd. Tukwila, WA 98188 206 / 431 -3670 i. ~ w� C42 UO No. • W= J w o (11. • I w. z = � z ►- • U . U , r• .w w z Location (Roar/room no.) S F oor Fixture Description Fluorescent Par. - Number of Fixtures Wens/ Fixture , Warts Proposed n • oor Lam. T8 -32W Electro•c Balla. '2nd Floor Office Area r Location (floor /ream no.) Occupancy Description Allowed Win pe It' " Ares in h Mowed x Area 1st Floor_ Office Area '2nd Floor Office Area 03/22/2000 17:05 4253380827 vv u w:u /A ■.41 ..� r • r . Li G -SUM Wa•M IMP NMrtteeeu•txr Enemy Cads 1997 Washin • • 'Stage Nonr Project Info Pro 600 Andover Pk W Tukwila, WA App eInlNama:ECS Engineering. Inc. ' APPlical 4 Addreu16030 Bothell- Everett Hwy #100 AppkAntPhone: ( 425) 338 -2416 Mill Creek WA 9 Compliance Option ❑ New Sawn U Addition ECS ENGINEERING Cori Con► • Form Alteration Dale 012 Prescriptive CI Lighting Power Alowence CI System, Analysis (See 4vetinoatian Check Mat (over). indicate Preaerlptive A LPA spares dourly on plans.) f'WUt tJL/ t13 Mrs E P. O Juno tee* - I 3 -22 -00 For Building Department Alteration Exceptions O changes are being made to the lighting (cheek appropriate boa) No then 60% of She fixtures are new and instafed fighting wattage is net being increased Use mtgr Mated maximum Input wattage. For Assures with hare -wired baeasts only, the Maximum Allowed Li tin Wattage (Inter! detainable in the NREC Technical Reference Manual MO y also be used Proposed Lighting Wattag (Interior) (May not exceed Total Allowed Warta for Inferior) Proposed Lighting Wattage (Exterior) Location " From Table 15.1 (ever) • document al exceptions taken from footnotes Tole/ Allowed Warta Total Propeaed Watts may riot exceed Total At owed Watts for Interior Description overed Parking N/A Open Parking okmoor Areas Bldg. (by facade) Bldg. (by poem) Note: for bu i tng exterior, choose ether the facade area or the perimeter method, out not both) Total Proposed Watts may not exceed Total Mowed Woes ter Exterior D Zo oOo9 l Use migr listed maximum Input wattage. For Routes with hardwired ballasts cow, the default table in the NREC Technical Reference Manual may also be used. Allowed Watts per h' or per If 0.a Witt' 0.2 W/tt G� e 0.26 wm 7.5 Writ Pro • osed Li htin : Watta: e (Exterior) (May not exceed Total Allowed Watts for Exterior) etas Proposed Watts Area in h (or If for perimeter) Total Allowed Watts Total Proposed WOOS Allowed Wamt x or if) Location Fixture Description N/A Number of Fixture' Wane/ Wars Fixture Proposed EIVED -- CIN OP W ILA MAR 2 i 2000 PERMIT CENTER Z I I ~ w 00 W = F U) LL w° 2 u Q = d I— Z I— O Z F- W U � O- 0 F— w F- tL 0 W U= O F- Z Use' LPA (Witt') Use' LPA (WRt Painting, welding, carpentry, machine shops 2.3 Police and fire stations 1.2 Barber shops, beauty shops 2 Atria (atriums) I Hotel banquet /conference /exhibition hai 2 Assembly spaces ° , auditoriums, gymnasia ° , theaters 1 Laboratories 2 Process plants 1 Aircraft repair hangars 1.5 R estaurants /bars 1 Cafeterias, fast food establishments 1.5 R stall A 1 Factories, workshops, handling areas 1.5 R stall B Retail banking 1.5 Gas stations, auto repair shops 1.5 Locker and/or shower facilities 0.8 Institutions 1.5 W are houses ", storage areas 0.5 Libraries 1.5 Aircraft storage hangars 0.4 Nursing homes 1.5 Parking garages s" Seercn '532 Wholesale stores (pallet rack shelving) 1.5 Malt concourses 1.4 Plans Submitted for Common Areas Oniy Schools buildings, schoolclass:ooms, day care centers 1.35 Common area, corridors, lobbies (except mall concourse) 0.8 Laundries 1.3 Toilet facilities and washrooms 0.8 Office buildings, office /administrative areas in facilities of other use types (including but not limited to schools, hospitals, Institutions, museums, banks, churches) 1.2 Prescriptive Spaces Occupancy ❑ Warehouses, storage areas or aircraft storage hangers Qualification Checklist Note: If occupancy type Is 'Other' and fixture answer is checked, the number of fixtures In the space is not limited by Code. Clearly Indicate these spaces on plans. if not qualified, do LPA Calculations. Lighting Fixtures: 1Check here if at least 95% of fixtures In the space meet all four criteria: 1. Fixtures are fluorescent, non - lensed, with only one or two lamps, and 2. Lamps are T -5, T-6, T -8 or PL, and 3. Lamps are 5 -50 Watts, and 4. Ballasts are electronic ballasts 4 Lighting Summary ( LTG -SUM 1997 Washington State Nonresidential Energy Code Compliance Forms 1997 Washington State Nonresidential Energy Code Compliance Form Table 15 -1 Unit Lighting Power Allowance (LPA) for Interior Lighting Footnotes for Table 15-1 on•June 1999 1. In cases in which a use is not mentioned specifically, the Unit Power AUnwrrnce shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2. The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3. Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4. For all other spaces, such as seating and common areas, use the Unit Light Power A lloK+ance fcr assembly. 5. Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6. Includes pump area under canopy. 7. In cases in which a lighting plan is submitted for only a portion of a floor, a Unit Lighting Power Allowance of 1.35 may be used for usable office floor area and 0.80 watts per square foot shall be used for the common areas, which may include elevator space, lobby area and rest rooms. Common areas, as herein defined do not include mall concourses. 8. For the fire engine room, the Unit Lighting Power Allowance is 1.0 watts per square foot. 9. For indoor sport tournament courts with adjacent spectator seating, the Unit Lighting Power Allowance for the court area is 2.6 watts per square foot. 10. For both Retail A and Retail B, light for free - standing display, building showcase illumination and display window illumination installed within two feet of the window are exempt. Retail A allows a Unit Lighting Power Allowance of 1.0 watts per square foot. Ceiling mounted adjustable tungsten halogen and HID merchandise display illuminaries are exempt. Retail B allows a Unit Lighting Power Allowance of 1.5 watts per square foot, including all ceiling mounted merchandise display luminaries. 11. Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be definer 0F�'u IA computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. ; MAR 2 4 20011 PERMIT CENTER• TUES /THURS ROUTING: Please Route Approved \PRROUTE.DOC 5/99 itit die PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D2000 -091 DATE: 4 -18 -2000 PROJECT NAME: KING COUNTY HOUSING AUTHORITY SITE ADDRESS: 600 ANDOVER PARK WEST Original Plan Submittal Response to Incomplete Letter #__ XX Response to Correction Letter # 1 Revision # _ After Permit Is Issued DEPARTMENTS: BuiIdNg. ivisiop Fire Prevention Public Works Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE:4 -20 -2000 Complete n Incomplete n Comments: CORRECTION DETERMINATION: Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: (ten days) Approved with Conditions Approved Approved with Conditions REVIEWER'S INITIALS: n n Planning Division Permit Coordinator Not Applicable n No further Review Required n DUE DATE 5 -11 -2000 Not Approved (attach comments) F1 REVIEWER'S INITIALS: DATE: DUE DATE Not Approved (attach comments) n DATE: ACTIVITY NUMBER: D2000 -091 DATE: 3 -24 -2000 PROJECT NAME: KING COUNTY HOUSING AUTHORITY SITE ADDRESS: 600 ANDOVER PARK WEST XX Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Is Issued DEPARTMENTS: CsP, Nc sir2�� Public Works 11 LIm ilia_ 4 3.2 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete APPROVALS OR CORRECTIONS: (ten days) Approved \PRROUTE.DOC 5/09 Approved with Conditions PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP i5I0 Fire Prev tion 400 Structural Incomplete TUES /THURS ROUTI G: Please Route Structural Review Required REVIEWER'S INITIALS: n REVIEWER'S INITIALS: Planning Division 3 -2$ -00 Permit Coordinator DUE DATE:3 -28 -2000 Not Applicable Comments: No further Review Required DUE DATE 4 -25 -2000 or as n DATE: Not Approved (attach comments) DATE: CORRECTION DETERMINATION: DUE DATE Approved Approved with Conditions Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: City of Tukwila Department of Community Development z ~ w cc 2 J U 00 CO lJ. w 2 ua m a = Z = Z0 w tu Project Name: 1 1t G Co U14T 4 OcIS 1 0t - 1-3'OR l7 n 0 Project Address: Gam= 9 Jt \1 G0- a ~ Contact Person: LVstil7 r a Co 12S Phone Number. 4 3 3 -'75 a �? LLO z kc Summary of Revision: T ek eJ I.p�`t o :Z v on oI Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: ❑ Response to Incomplete Letter # Er Response to Correction Letter # ❑ Revision # after Permit is Issued I s -Entered in Sierra on 1 — )00 U' Plan Check/Permit Number: D`2-; z ^ I John WoRants, Mayor _ Steve Lancaster, Director CIVOETh LA LAPP 1 'tnn i.v ( Mi f CENTER Sheet Number(s): "Cloud" or highlight all areas of revision including of revision Received at the City of Tukwila Permit Center by: ` R.Ct Wl 06/29/99 00 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • (206) 4313670 • Far (206) 4.313665 �ua .m w.xw�..M ots wnrarw•n n.w +e7+ .. .. »..M....•,. +rr- ..�•:....,• nMh..+w.wr.r..•.rua • wmsu..*u•C V ir.! ltq•:M:?rT.�h4Y74 't5"N°s!`C:1 *t �4'C S�Yd,;?". "K�3 �%r P4:. k +'�`t'�M7S�°`?�45;� z Ciiy of Tukwila Fire Department Thomas R Keefe, Fire Chief z April 3, 2000 rX 2 • -I U U O CO o III �j (S. � Re: King County Housing Authority - 600 Andover Park West z� 1-0 z w w U 0 O— w 1. The total number of fire extinguishers required for LL your establishment is calculated at one extinguisher for —0 each 3000 sq. ft. of area. The extinguisher(s) should be uiN of the "All Purpose" (2A, 10B:C) dry chemical type. Travel v = . distance to any fire extinguisher must be 75' or less. pt- (NFPA 10, 3 -1.1) z Portable fire extinguishers shall be securely installed on the hanger or in the bracket supplied, placed in cabinets or wall recesses. The hanger or bracket shall be securely and properly anchored to the mounting surface in accordance with the manufacturer's instructions. The extinguisher shall be installed so that the top of the extinguisher is not more than 5 feet above the floor and the clearance between the bottom of the extinguisher and the floor shall not be less than 4 inches. Fire Department Review Control #D2000 -091 (510) Dear Sir: The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be identified with a sign stating, "Fire Extinguisher ", with an arrow pointing to the unit. (NFPA 10, 1 -6.3) (UFC Standard 10 -1) Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5) Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206 -575 -4404 • Fax: 206 -575 -4439 Steven M. Mullet, Mayor Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. (NFPA 10, 4 -3, 4 -4 and 4 -4.3) Every six years, dry chemical and halon type fire extinguishers shall be emptied and subjected to the applicable recharge procedures. (NFPA 10, 4 -4.1) If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 2. No point in a sprinklered building may be more than 250 feet from an exit, measured along the path of travel. (UBC 1004.2.5.2.2) Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 1207.3) Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (UFC 1207.3) Exit hardware and marking shall meet the requirements of the Uniform Fire Code. (UFC 1207 -1212) Gates and barriers shall be openable without the use of a key or any special knowledge or effort. Gates and barriers in an exit shall not be locked, chained, bolted, barred, latched or otherwise rendered unopenable at times when the building or area served by the exit is occupied. (UFC 1208.2) Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206 - 575.4404 • Fax: 206.575 -4439 City of Tukwila Fire Department Thomas P. Keefe, Fire Chief Page number 2 , • StevenM. Mullet, Mayor z ~ w 0 00 co Wi- NW W 0 w d I z � z O Lu U D O co 0 H W L —O w z U = O~ z City of Tukwila Fire Department Thomas P. Keefe, Fire Chief Page number 3 Steven: M. Mullet, Mayor When two or more exits from a story are required, exit signs shall be installed at the required exits and where otherwise necessary to clearly indicate the direction of egress. (UBC 1003.2.8.2) Exits shall not pass through kitchens, storerooms, restrooms, closets or spaces used for similar purposes. (UBC 1004.2.2) When two or more exits from a story are required and when two or more exits froma room or an area are required, exit signs shall be illuminated. (UBC 1003.2.8.4) Manually operated edge- or surface- mounted flush bolts and surface bolts are prohibited. When exit doors are used in pairs and approved automatic flush bolts are used, the door leaf having the automatic flush bolts shall have no door knob or surface- mounted hardware. The unlatching of any leaf shall not require more than one operation. (UFC 1207.3) All exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 1 1/2 hours in case of primary power loss, the exit signs shall also be connected to an emergency electrical system provided from storage batteries, unit equipment or an on site generator set, and the system shall be installed in accordance with the electrical code. (UBC 1003.2.8.5) 3. Maintain sprinkler coverage per N.F.P.A. 13. Addition /relocation of walls, closets or partitions may require relocating and /or adding sprinkler heads. All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206 -575 -4404 • Fax: 206 -575 -4439 .... z � • Z 6 U 0 U) CO 11.1 WI CO W 2 � Q = • d I- Ili Z �. I- O Z I- w 2o 0 0— o H- w u I ; O W z U N 1= O~ z City of Tukwila W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recognized by The City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1742) All sprinkler system plans, calculations and the contractors Materials and Test Certificates submitted to The Tukwila Fire Prevention Bureau must be stamped with the appropriate level of competency seal. (WAC 212 -80) Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1742) Steven M. Mullet, Mayor Fire Department Thomas P. Keefe, Fire Chief z �z ce w Page .....L....... n 6 V U ND WI CO w O. 2 u.Q w I- I` 1- O Z i-- w U � ON w il l � L ui U 4. An approved manual fire alarm system is required for z this project. The fire alarm system shall meet the requirements of the Americans With Disabilities' Act, chapter 51 -20 WAC (Chapter 31 Accessibility), N.F.P.A. 72 and the City of Tukwila Ordinance #1742. All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1742) (UFC 1001.3) Local U.L. central station supervision is required. (City Ordinance #1742) Dedicated fire alarm system circuit breaker(s) shall be equipped with a mechanical lockout device. (NFPA 72 (1- 5.2.8.2)) Remote alarm annunciation indication is required if the control panel is not visible from the main entrance. (City Ordinance #1742) When the control panel is located inside a room, the Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206.575 -4404 • Fax: 206 -575 -4439 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206 -575 -4404 • Fax: 206-575-4439 City of Tukwila Fire Department Thomas P. Keefe, Fire Chief z �w • Page number 5 00 co W = WO door to the room shall have a sign with one -inch letters which reads "Fire Alarm" or "Fire Alarm m d Control ". (City Ordinance #1742) w 5. All electrical work and equipment shall conform z i strictly to the standards of The National Electrical Code. z 0 0. (NFPA 70) j . An aisle to and working space shall be provided for v O each electrical panel. An aisle width not less than o - - 24 inches shall provide access to the panel and 30 w inches of working space shall be provided directly in w i front of the panel. (NEC 110-16(a), NEC 110-16(c)) F= Each circuit breaker shall be legibly marked to tii indicate it's purpose. (NEC 110 -22) 0 _. I 6. Your street address must be conspicuously posted on the building and shall be plainly visible and legible from the street. (UFC 901.4.4) 7. This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. 8. Accumulation of combustible waste material is prohibited during the demolition phase of this project. Remove and properly dispose of all waste material prior to the close of the working day and as often throughout the day as needed. Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. ,, ,"," � Steven' M. Mullet, Mayor Page number 6 Yours truly, City of Tukwila Steven M. Mullet, Mayor Fire Department Thomas R Keefe, Fire Chief cc: TFD file ncd The Tukwila Fire Prevention Bureau Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206-575-4404 • Fax: 206-575-4439 . KING COUNTY HOUSING AUTHORITY CENTRAL OFFICE 600 ANDOVER PARK WEST TUKWILA, WA 98188 TENANT IMPROVEMENT FILE COPY Check approvals are fissions and approval of understand that the Plan of any pla je does of and violation ns does not authorize the pd code or ordnance. Receipt of con - adopted rov -dplansack nowledged. tractor's �' = i , ( , i � � 5 By /I Date Permit No. SEPARAT REQUIRED FOR. ECHANICA ECTRICAL PLUMBING PIPING crrf OF TUKY -. BUILDING OMtSSO a' 1■ - / /N► I /A # 1 SYNTHS ISLLC THE FUSION OF ARCHITECTURE. DESIGN TECHNOLOGY & PEOPLE ISSUE NO. 2353 13001 Avenue NE, Seale 202 Bellevue, WA 98005 425 8691946 (fax) 425 885 6208 Sssk ssign 0200 DESIGNED BY. Inferior Planning & Design PHONE 206 236 -7273 FAX 206 236 -1240 rjseeks@aof_com CELL 206 605 -1501 4259 EAST MERCER WAY MERCER ISLAND, WA 98040 REVISIONS PROFESSIONAL STAMP -091 ITEM PROJECT • INFORMATION KING CO. HOUSING AUTHORITY TENANT IMPROVEMENTS CENTRAL OFFICE 600 Andover Park West Tukwila, WA 98118 SHEET INFORMATION RELEASEPOR• ISSUED. FOR PERMIT REVIEWED BY. APPROVED BY• Dpi. 03/23/2000 SNIET NO• PROJEOT No. 98009.03.000 OW OFTUKWIIA MAR 2 4 2000 aaaa BY• PERMITGENTER ABBREVIATIONS ( m AB AC A/C ACP ACT ADD AOH ADJ ADJT AFF AGG AL ALT AP APPROX ARCH AWF AWP BD BEAR BLDG BLK BIM BM BRG HOT BSMT BUR CAB CB CBU GEM CER CFCI CFO! CFM CC CHBD CI, CJT CLG CJ' CUT CLR CMU CNTR Co COL CONC CONN CONSTR CONT CORR CPT CT CTR CTSK CY DBL DEPT DET DIA DAG DIM DISP DMPF DN OR DWR DS DW DWG ANGLE CENTER LINE CHANNEL DIAMETER OR ROUND NUMBER OR POUND PENNY SQUARE FOOT PLATE ANCHOR BOLT ACOUSTICAL OR ASPHALT CONCRETE AR CONDITIONING ACOUSTICAL PANEL ACOUSTICAL TILE ADDITIVE ADHESIVE ADJACENT ADJUSTABLE ABOVE FINISH FLOOR AGGREGATE ALUMINUM ALTERNATE ACCESS PANEL APPROXIMATE ARCHITECTURAL ACOUSTICAL WALL FABRIC ACOUSTICAL WALL PANEL BOARD BETWEEN BUILDING BLOCK BLOCKING BEAM BEARING BOTTOM BASEMENT BUILT UP ROOF CABINET CATCH BASIN CEMENTITIOUS BACKER UNIT CEMENT CERAMIC CONTRACTOR FURNISH - CONTRACTOR INSTALL CONTRACTOR FURNISH- OWNER INSTALL COBIC FEET PER MINUTE CORNER GUARD CHALK BOARD CAST IRON CONTROL JOINT CEILING CONSTRUCTION JOINT CAULKING CLEAR CONCRETE MASONRY UNIT COUNTER CLEANOUT COLUMN CONCRETE CONNECTION CONSTRUCTION CONTINUOUS CORRIDOR CARPET CERAMIC TILE CENTER COUNTER SINK CUBIC YARD DEEP, DEPTH DOUBLE DEPARTMENT DETAIL DIAMETER DIAGONAL DIMENSION DISPENSER DAMPPROOFING. DOWN DOOR OR DRAIN DRAWER DOWNSPOUT DISHWASHER DRAWING GENERAL NOTES EA EB EJ EIFS EL ELEC ELEV EMER ENCL EWC EQ EQPT ESEW EST EXIT EX EXST EXP EXT FA FB FBD FBO FCIC FCTY FD EON FE FEC AN FL EEG FLUOR FOC FOF FDIC F010 FOS FEW FS FT ETC FURR FUT GA GALV GB GL GLBM GC GOD GWB GYP HB HBD HC HD HDR HDWD HOWE HM HORIZ HR HT HTG HVAC NCL NSUL NT NV JAN JST JT KO KS EAST EACH EXPANSION BOLT EXPANSION JOINT EXTERIOR INSULATED FINISH SYSTEM ELEVATION ELECTRIC ELEVATOR EMERGENCY ENCLOSURE OR ENCLOSED ELECTRIC WATER COOLER EQUAL EQUIPMENT EMERGENCY SHOWER/ EYE WASH ESTIMATE EXHAUST EXPANSION EXISTING EXPOSED EXTERIOR FIRE ALARM FLAT BAR FIBER BOARD FURNISHED BY OTHERS FURNISHED BY CONTRACTOR INSTALLED BY CONTRACTOR FACTORY FLOOR DRAW FOUNDATION FIRE EXTINGUSHER ARE EXTINGUSHER CABINET FINISH FLOOR FLASHING FLUORESCENT FACE OF CONCRETE FACE OF FINISH 11RNISH BY OWNER INSTALL BY CONTRACTOR FURNISH BY OWNER INSTALL BY OWNER FACE OF STUD FREEZE PROOF WALL HYDRANT FULL SIZE FEET FOOTING FURRING FUTURE GAGE GALVANIZED GRAB BAR GLASS OR MATING GLU -LAM BEAM GENERAL CONTRACTOR GROUND GYPSUM WALL BOARD GYPSUM HOSE BIB HARD BOARD HOLLOW CORE OR HANDICAP HAND DRYER HEADER HARD WOOD HARDWARE HOLLOW METAL HORIZONTAL HOUR HEIGHT HEATING HEATING/VENT001ION/ AIR CONDIBONING HWH HOT WATER HEATER INSIDE DIAMETER/ DIMENSION INSULATED GLASS INCH RICLUDE INSULATION INTERIOR INVERT JANITOR JOIST JOINT KNOCK OUT KNEE SPACE LAM LAV LB LF LG LH LL INS LT LWC MAY MAT_ MAX MB MDo MDE MECH MEND TAR MEZZ MFR MIN MR MISC MO MID MULL NIC NOTI NRC NIS OA OBS OC OFC1 OECD co OH OFR OPRG OPP PBD PER PL PLAN PLAS FWD PM_ TNT POI PR PSE PSI PT PN PTD /R PIN PTR PVC PVMT OT RA RB RIBS RD RO /0 REF REFR ROOF RED REV RH REAL RO Rif RO RE RUB RWL LAMINATE LAVATORY LAG BOLT UNEAL FOOT LONG, LENGTH LAMINATED GLASS LEFT HAND LAVE LOAD LIQUID MARKING SURFACE LIGHT LIGHT WEIGHT CONCRETE MASONRY MATERIAL MAXIMUM MACHINE BOLT MEDIUM DENSITY OVERLAY MEDIUM DENSITY FIBERBOARD MECHANICAL MEMBRANE METAL MEZZANINE MANUFACTURER IAN HOE MWNUM MIRROR MISCELLANEOUS MASONRY OPENING MOUNTED MULLION NORTH NOT IN CONTRACT NUMBER NOIMNAL NOISE REDUCTION COEFFICIENT NOT TO SCALE OVERALL OBSCURE ON CENTER OWNER FURNISH- CONTRACTOR INSTALL OWNER FURNISH- OWNER INSTALL OUTSIDE DIAMETER/ DIMENSION OVERHEAD OPPOSITE HAND OPENING OPPOSITE PARTICLE BOARD PERPENDICULAR PLATE OR PROPERTY UNE PLASTIC LAMINATE PLASTER PLYWOOD PANEL PAINT POLISH PAIR POUNDS PER SQUARE FOOT POUNDS PER SQUARE INCH PRESSURE TREATED PAPER TOWEL DISPENSER PAPER TOWEL DISPENSER AND RECEPTABLE PARTDON PAPER TOWEL RECEPTATLE POLYVINYL CHLORIDE PAVEMENT QUARRY TILE RISER, RADIUS RETURN AR RESIDENT BASE ROD & SHELF ROOF DRAIN ROOF DRAIN OVERFLOW REFERENCE, REFLECTED REFRIGERATOR REINFORCED REQUIRED REVISION RIGHT HAND OR ROBE HOOK RESNJENT ROUGH -IN ONLY ROOM ROUGH OPENING REUUENT/RUBBER TILE RUBBER RAIN WATER LEADER SC SCD SCHD SD SECT SF SHT SHTG' SG SRI SK SIR SND SNR SNT SPEC SPGL SO 55 SST 55K STA STC STN STD SR_ STIR STRL SUSP 5V 5YM sic TB TAB TAN TG THK THR TIC TKBD' TO TOP TOS TOOL TOW TPD TPH TPTN TS N TYP UL LION UR VAR ALT VENT VERT VEST VNR VB VWC SOUTH SOLID CORE SEAT COVER DISPENSER SCHEME SOAP DISPENSER OR STORM DRAIN SECTION SQUARE FEET SHEET SHEATHING SOLAR INSULATED GLAZING SIMIBAR SINK SEVER SANITARY NAPKIN DISPENSER SANITARY NAPKIN RECEPTAXE SEALANT SPECIFICATION SPANDRE GLASS SQUARE SOLID SURFACING STAINLESS STEEL SERVICE SINK STATION SOUND TRANSMISSION CLASS STAIN STANDARD STEEL STORAGE STRUCTURAL SUSPENDED SHEET VINYL SYMMETRICAL SPECIAL WAIL COVERING TREAD TOWEL BAR TOP A BOTTOM TONGUE A GROOVE TEMPERED GLASS THICK THRESHOLD TEMPERED INSULATED GLAZING TACK BOARD' TOP OF TOP OF CONCRETE TOP OF PAVEMENT TOP OF STEEL TOP OF SLAB TOP OF WALL TOILET PAPER DISPENSER TOILET PAPER HOLDER TOILET PARTITION TUBULAR STEEL TELEVISION TYPICAL W/ W/0 WC WD WDO WG WM WP WR WSCT WT WWF XFMR TRANSFORMER YD YARD UNDERWRITERS LABORATORY UNLESS OTHERWISE NOTED URINAL VARIES VINYL COMPOSITION TILE VENTILATOR VERTICAL VESTIBULE VENEER VAPOR RETARDER VINYL WALL COVERING WITH WITHOUT WATER CLOSET WOOD WINDOW WIRE GLASS WIRE MESH WATER PROOF WATER RESISTANT WAINSCOT WEIGHT WELDED WIRE FABRIC 1. CONTRACTORS SHALL VISIT THE PROJECT SITE TO BECOME FAMILIAR WITH THE SCOPE OF WORK. MAKE ARRANGEMENTS WITH THE OWNER FOR SITE VISIT AND DATE. 2. ALL WORK SHALL COMPLY WITH APPUCABLE CODES AND ORDINANCES. 3. VERIFY ALL EXISTING CONDITIONS, DIMENSIONS, DETAILS, ETC. NOTIFY ARCHITECT OF ANY AND ALL DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK. 4. CONTRACTOR SHALL KEEP AREAS UNDER CONSTRUCTION CLEAR OF DIRT AND DEBRIS CAUSED BY DEMOLITION AND SHALL STORE CONSTRUCTION MATERIALS AND EQUIPMENT IN AREAS DESIGNATED BY THE OWNER. 5. CONTRACTOR IS TO VERIFY DIMENSIONS AND CONDITIONS SHOWN ON THE DRAWINGS AND SHALL BE RESPONSIBLE FOR THE JOINING OF HIS WORK TO THE WORK OF OTHER TRADES. DISCREPANCIES ON THE DRAWINGS AND SPECIFICATIONS. IF ANY, SHALL BE BROUGHT TO THE ATTENTION OF THE OWNER IMMEDIATELY IN WRITING UPON DISCOVERY. 6. CONTRACTOR SHALL CHECK WITH THE OWNER FOR STAGING AREA AND SECURITY REGULATIONS. 7. REPETITIVE FEATURES NOT NOTED ON THE DRAWINGS SHALL BE COMPLETELY PROVIDED AS IF DRAWN IN FULL. 8. DIMENSIONS ON THE DRAWINGS ARE TAKEN TO THE FACE OF MASONRY AND /OR CONCRETE WALLS, TO THE FACE OF STUDS, AND TO THE CENTERLINE OF WINDOW MULLIONS. UNLESS OTHERWISE NOTED. VERIFY ELEVATIONS & LOCATIONS TO BE JOINED BEFORE CONSTRUCTION. CONTACT ARCHITECT IF THEY DIFFER FROM THOSE SHOWN ON THE DRAWINGS. DO NOT SCALE DRAWINGS; DIMENSIONS GOVERN. 9. PROVIDE CLOSURE, MEETING THE REQUIREMENTS OF THE GOVERNING FIRE AUTHORITIES. BETWEEN ALL FIRE RATED BUILDING PARTITIONS AND ANY PENETRATING DUCTS, PIPES, CONDUIT, MECHANICAL; ELECTRICAL, AND ALL OTHE EQUIPMENT. 10. EACH CONTRACTOR SHALL CONSULT PLANS OF ALL TRADES FOR ALL OPENINGS THROUGH NEW OR EXISTING CONSTRUCTION FOR DUCTS, PIPES, CONDUIT. CABINETS, AND EQUIPMENT AND SHALL VERIFY SIZE AND LOCATION. 11. EACH CONTRACTOR SHALL VERIFY ALL ROUGH -1N DIMENSIONS FOR EQUIPMENT FURNISHED AND INSTALLED BY HIMSELF OR OTHERS. 12. ALL FURNISHED ITEMS SHALL BE SUPPLIED WITH REQUIRED MECHANICAL AND ELECTRICAL SERVICES TO PROVIDE OPERATION OF ITEMS FURNISHED. 13. ROOM FINISH SCHEDULE SHALL NOT BE TAKEN AS COMPLETE SPECIFICATIONS FOR ALL INTERIOR ROOM MATERIALS HOWEVER IT SHALL BE BINDING TO THE EXTENT OF THE MATERIAL IT DOES SPECIFY, FOR OTHER MATERIALS NOT COVERED BY THE SCHEDULE, CONTRACTOR TO VERIFY WITH THE ARCHITECT. 14. PLANS WHICH APPEAR AS BACKGROUNDS ON ENGINEERING DRAWINGS ARE FOR THE PURPOSE OF ILLUSTRATING GENERAL PLAN CONFIGURATION ONLY. SUCH BACKGROUNDS SHALL NOT BE USED FOR PORTIONS OF THE WORK OTHER THAN THAT PERTAINING TO THE TITLE OF EACH SHEET. REFER TO THE APPROPRIATE SHEET FOR EACH SPECIFIC PORTION OF THE WORK. 15. THE GENERAL CONTRACTOR AND RESPECTIVE SUBCONTRACTORS SHALL BE RESPONSIBLE FOR THE COORDINATION OF MECHANICAL AND ELECTRICAL WORK. MECHANICAL AND ELECTRICAL DRAWINGS. SHALL BE REFFERRED TO IN DETAIL FOR COORDINATION OF REQUIREMENTS. 16. CONSULT WITH MECHANICAL CONTRACTOR FOR EXACT LOCATIONS FOR ACCESS REQUIRED BY THEIR WORK. ACCESS MUST BE PROVIDE FOR ALL CONCEALED VALVES, DAMPER CONTROLS, AND FIRE DAMPERS LINKAGE. OBTAIN ARCHITECT'S APPROVAL IN LOCATING ACCESS DOORS. 17. ALL PIPING, CONDUIT, DUCTS, ETC., SHALL BE FURRED -IN IN ALL FINISHED ROOMS. 18. PLACE NO MAINS, PIPING, CONDUIT, OR OBSTRUCTIONS OF ANY KIND SO AS TO IMPAIR GIVEN CEILING HEIGHTS AND CLEARANCES. 19. ALL DIMENSIONS DETERMINED BY EQUIPMENT OR CABINETRY ARE TO BE CHECKED AND VERIFIED WITH EQUIPMENT OR CABINETRY DIMENSIONS. 20. MECHANICAL EQUIPMENT SHALL BE ISOLATED FOR SOUND AND VIBRATION. 21. ALL DUCTWORK AND PIPING SHALL BE ISOLATED FOR SOUND AND VIBRATION WHEN SUSPENDED FROM THE STRUCTURE ABOVE. 22. ALL DOORS NOT LOCATED BY DIMENSION ON PLANS OR DETAILS SHALL BE 4 FROM FACE OF ADJACENT WALL EDGE OF DOOR OPENING OR CENTERED BETWEEN ROOM PARTITIONS AS SHOWN UNLESS OTHERWISE NOTED. 23. ALL GLAZING SHALL BE CERTIFIED AND LABELED WITH ITS U- FACTOR AND SOLAR HEAT GAIN COEFFICIENT (SHGC) BY AN INDEPENDENT AGENCY LICENSED BY THE NFRC. SYMBOLS NORTH COLUMN LINE /GRID UNE DOOR NUMBER DOOR TYPE KEY NOTE WALL TYPE REVISION/ CLOUDED AREA MATCH UNE VICINITY MAP WORK POINT, CONTROL POINT OR DATUM POINT SECTION IDENTIFICATION/ SHEET NUMBER DETAIL IDENTIFICATION/ SHEET NUMBER INTERIOR ELEVATION IDENTIFICATION/ SHEET NUMBER OFFICE ROOM IDENTIFICATION/ NUMBER 100 NORTH PROJECT NORTH 0 EXTERIOR GLAZED OPENING NO. <EQ -I> EQUIPMENT IDENTIFICATION (PL -1) FINISH IDENTIFICATION LEGAL DESCRIPTION THAT PORTON OF THE NOR -EAST QUARTER OF THE SOUTHEAST QUARTER OF SECTION 26, TOWNS* 23 NORTH, RANGE 4 EAST, W.M., IN KING COUNTY. WASHINGTON. DESCID AS FOLLOWS: COI&ENCNG AT TIE SOUTHWEST CORNER OF THE SAID NORTHEAST QUARTER OF THE SOUTHEAST QUARTER THENCE SOUTH 118' lY 3Y EAST 30.00 FEET TO THE POINT OF ORIGIN OF THE CENTERLINE ON THE P -17 DRAINAGE CHANNEL, WHICH CHANNEL CONIWAIES SOUTH 88' 12' 32' EAST TO TERMINUS AT THE WESTERLY MARGIN OF CRISTQ6EN ROAD; THENCE CONIIMIING SOUTH 86' 12' 32" EAST 360.00 FEET; THENCE NORTH or 47' 28' EAST 69.00 FEET TO THE NORTHERLY MARGIN OF MINKLER BOULDAND; TIWIICE CONIWIIRIG NORTH 01' 4Y 28' EAST 319.00 FEET TO THE TRUE POINT OF BEGWRIO,OF THE PARCEL TO BE DESCRIBED HEREIN; THENCE FROM SAD TRUE PRAT. OF DEIN*W G NORTH air 12' 32' WEST 360.00 FEET THE EASTERLY. MGR OF ANOOLER PARK WEST AS RECORDED UNDER AUDITOR'S FEE NO. 6355529, DOME 5095, PAGES 63 AND 64, RECORDS of KING COUNTY, . WASHINGTON; THENCE ALONG SAD EASTERLY MMWYN NORTH or 47 28' EAST 150.00 FEET; THENCE LEAVING SAD EASTERLY WREN SOUTH 88' 17 32" EAST 360.00 FEET; THENCE SOUTH 01' 47' 28 REST 150.00 FEET TO THE TRITE POINT OF BEGINNING. CODE INFORMATION CODE EDTIIIk 1997 UDC, 1997 UPC AND IAIC,HEEC, 1995 WSEC, WPC 51 -11, WAG 51 -13 Amended by Local Juedelian ❑ Yes Xl No Dale 116 New Canshuctim ❑ Addition ❑ Bulling Std Only ® Tenant Improvement 1997 UBC ANALYSIS Se RAIN 301 (Fable 3-A) - OCCUPANCY OASSFICUTON(S): Regrind Occupancy Sepmatims (Table: 3-B) ® No Requirement ❑ Two-hour Fire Resistive ❑ One-ltarr FA Restive ❑ Three -has Fire Resistive SECTION 503 - LOWER ON PROPERTY: Distance to Openings Property Line Permitted North 15 Ft ❑ Yes No East 180 Ft ❑ Yes ❑ No South 7'1 Ft ❑ Yes ❑ No West 80'.. Ft ❑ Yes ❑ No SECTION 504 - MI /®MIT ROOK AiRk KT Basic Allowable Arco ( Tale 5-B) TE MS-story Baiting (x 2) ❑ Arm. Separation Waits (504.6) 1 No ❑ Two Hour ❑ Four Hour SECTION 505 - MH/*IAF AREA NL ❑ Separation 2 Sides; (Over 201 Ft x 1.25% ( 50% Marimwn)= ® Separation 3 Sdes. (Ow 20') 51 Ft x 2505 (1002 Mmimwn)= ❑ Separation 4 Side, (aver 20') Ft x 5J00X (1007C Mmimmr)= ® Fie Sprinklers Provided ❑ She -stay (x 3) III MID -stay (x 2) ❑ Ranged Armn, Approved F. Sprinkler System(505.2) BUILDING A€AS (DROSSk SECTION 601 - TYPE OF CONSTRUCTION SECWN 100322 - OCCUPANT LOAD 1 Areas .Trout Fared sealing (Table 10-A) 15E two NUMBER OF ▪ BEIDI AMINO OFFICE 19,886 SF 100 199 5. Special Regulations Applicable ❑ Shoreline Management Ad ❑ Rood Plain ar Wots.oy ❑ - &pod opera ass /9rde path ❑ Storm Water Retention/Run-Off ❑ Fre Lane Requirements 8. Parking Requirements - L1 Office ❑ AIeratian ❑ Repdr TENANT AREAS (GROSSk LOWER UPPER TOTAL SECTION 506 - MEM MIGHT OF WIll G5 NO INCREASES ❑ Are Spruddrrs Provided (1 Story - NA if sprinklers used for the inlaying) ❑ Section 90426 ® Section 505 ❑ Section 508 ❑ Section 402 ❑ Section 904.27 ❑ Arens dh fixed seating (111037771) ❑ Benches or PENS Total Length (inches) ' / 18 in = ❑ Boobs DATA Length (Indies) / 24 in = ZONING INFORMATION I. Jurisdiction CITY OF DACHA 2. Present sic use zame: C-M. Permitted IBA B =WANLY (NO CHANGE) 3. Projected sic use mires NO ACTION 4. Use Zone Adjacent Lots N NA E NA S NA W NA Action Required Action Required Action Required Action Required Action Required Openings Protected ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No HO BT Basic Wind Speed 80 MPH Seismic Zone 3 Snow Lead ❑ Four -hoar Fire Resistive ❑ Not Permitted Fire Resistance of Exterior Well REQUIRED NOM 39.8' 6. Setbacks Required: Front Yard NA Side Yard NA Rear Yard Actual: Front Yard NA Side Yard NA Rear Yard 7. Easements, Vocations, restrictive coevenatis es applicable Action Required ND CHANGE W BLHDNG OCCUPANCY OR SIZE - HOER RATIW REQUIRED 19,286 SF NA NA 9. Total Ste Area 54.120 SF 1.24 ACRES 8,000 SF 16.000 FS UNLIMITED 32,000 SF 64,000 SF 9,474 SF 10.412 SF 19,886 SF 2 STORES TYPE 5-N 199 PROVIDED NA Parking and Loading Stalls Actual NA Handicap NA Parking NA Total NA R Standard NA X Compost NA size standard stall NA size compact stall INDEX OF DRAWINGS COVER SHEET T1.1 GENERAL INFORMATION A2.1 DEMOLITION FLOOR PLANS A2.2 FLOOR PLANS A3.1 DOOR SCHEDULE & WALL TYPES A3.2 ROOM FINISH SCHEDULE A5.1 INTERIOR ELEVATIONS A5.2 INTERIOR ELEVATIONS A6.1 REFLECTED CEILING PLANS A9.1 INTERIOR DETAILS A9.2 INTERIOR DETAILS 102.2 INTERIOR FINISH PLANS ID2.3 INTERIOR FINISH PLAN & FINISH SCHEDULE CONTACT LIST OWNER KING COUNTY HOUSING AUTHORITY 15455 - 65th AVE S SEATTLE, WA 98188 -2534 DESIGNER SEEKS DESIGN ASSOCIATES 4259 EAST MERCER WAY NONE MERCER ISLAND, WA 98040. NONE NA NA NA COMMUNICATION ENGINEERS: HARGIS ENGINEERS, INC. 600 STEWARTST. 11800. SEATTLE, WA 98101 MECHANICAL ENGINEERS: FS CONSULTING ENGINEERS 605 FIRST AVE. f400, SEATTLE.' WA 98104 -2224 ELECTRICAL ENGINEERS ECS ENGINEERING. INC. 16030 BOTHELL- EVERETT HWY. SUITE 1100 MILL WA 98012 PHONE (206) 244 -7750 FAX (206) 244 -1948 PHONE (206) 236 -7273 FAX (206) 236 -1240 E -MPIU NOTE ARCHITECT: NONE SYNTHESIS. LLC PHONE: (425) 869 -1946 NONE 2353 130TH AVE NE. STE 202 FAX (425) 885 -6208 BELLEVUE, WA 98005 E -WVL PHONE: (206) 448 -3376 FAX (206) 448-4450 E-MAIL: PHONE (206).622 -3321 FAX (206).622 -5804 E -MAIL•, PHONE' (425) 338 -2416 FAX (425) 338-0827 E -MAIL: CLAUDE E. DA CORSI ADMIN. SERVICES SPECIALIST JIM SEEKS PRINCIPAL seeksdesign0home.com ROGER OAKDALE ARCHITECT roger.oakdeIe11synthesisllc.com WALLY HEDMAN ENGINEER wally_hedman @hargiseng.cam MICHAEL ESHELMAN PRINCIPAL mceOfsi- engineers.com ELMO RAJAH ENGINEER rajah0ers- engineering.com.com S' THESISLLC THE FUSION OF ARCHITECTURE. DESIGN . TECHNOLOGY 8 PEOPLE REVISIONS D2000 -091 1531E NO. PROFESSIONAL STAMP :PROJECT INFORMATION KING CO. HOUSING AUTHORITY TENANT IMPROVEMENTS CENTRAL OFFICE 600 Andover Park West Tukwila, WA 98118 SHEET INFORMATION REI.EA5E FOR ISSUED FOR PERMIT RECEIVED TntE GENERAL INFORMATION MAR 2 4 2000 DESIGNED BY. RO DRAWN er. STAFF REVIEWED BY. APPROVED BY. DATE 2353 130th Avenue NE, Sule 202 Bellevue, WA 98005 425 8691946 (fax) 425 885 6208 Sssk Pssion A S S O 0 1 A T E S Interior Planning & Design PHONE 206 236 -7273 FAX 206 236 -1240 rjseeks @aol.G CELL 206 605 -1501 4259 EAST MERCER WAY MERCER ISLAND, WA 98040 DATE EEGI , CIiITEGT SLE -ICJ 03/23/2000 SHEET NO. PROJECT NO. 98009.03.000 GEM PERMIT CENTER T1.1 NORTH NORTH SECOND FLOOR DEMOLITION PLAN SCALE: 1 /8 " -1' -0" FIRST FLOOR DEMOLITION PLAN GENERAL DEMOLITION NOTES: CONDITIONS MAY VARY FROM THOSE SHOWN. THE CONTRACTOR IS TO'SCHEDULE A BUILDING WALK- THROUGH WITH THE OWNER BEFORE DEMOLITION TO IDENTIFY ITEMS TO BE SALVAGED AND CLARIFY DEMOLITION. THE CONTERACTOR IS TO REMOVE ALL DESIGNATED EQUIPMENT AND RETURN IN ORIGINAL CONDITION TO THE OWNER C. PROTECT PORTIONS OF EXISTING BUILDING OR STRUCTURES, WHICH ARE TO REMAIN, AGAIF"'T DAMAGE OF DISCOLORATION D. PROTECT ANY ITEMS OR EQUIPMENT TO REMAIN AGAINST DAMAGE E. WHERE EXISTING CONDITIONS ARE DEFACED OR MODIFIED DUE TO WORK PERFORMED, THE CONTRACTOR IS TO RESTORE SAME WITH FULL PIECES TO MATCH ADJOINING MATERIAL AND FINISH. REPAIRED FINISHES SHALL BE EXTENDED TO THE NEAREST VISUAL BREAK LINES SUCH AS CORNERS, CEILING LINES, TOP OF BASE AND SIMILAR F. VERIFY RELOCATION OR TERMINATION OF SERVICES IN WALLS OR CEILINGS TO BE REMOVED. COORDINATE WITH MECHANICAL AND ELECTRICAL G_ ADDITIONAL DEMOLITION, NOT DIRECTLY INDICATED HERE MAY BE REQUIRED DEMOLITION PLAN KEYNOTES: THIS AREA N.I.C. OFOI - OWNER TO REMOVE ALL CEILING TILE AND STORE SALVAGEABLE UNITS FOR REUSE IN ROOM 201 - OWNER TO DISPOSE OF SALVAGE: CEILING GRID TO REMAIN INPLACE AND BE REUSED THROUGHOUT ENTIRE BUILDING O OFOI - OWNER TO REMOVE ALL DEMOUNTABLE PARTITIONS AND DEMOUNTABLE DOORS FOR REUSE IN ROOM 201 - OWNER TO DISPOSE OF SALVAGE REMOVE CARPET - INCLUDING STAIRS O REMOVE SHEET VINYL O REMOVE CASEWORK O REMOVE WOOD BASE O REMOVE WOOD TRIM AND HANDRAIL AS REQUIRED FOR NEW CONSTRUCTION DEMOUNTABLE WALL AND DEMOUNTABLE DOOR TO REMAIN INPLACE 10 TILE. FIXTURES, PARTITIONS, AND CASEWORK TO REMAIN INPLACE - PROTECT <> WOOD HANDRAIL AND STAIR EDGING AGAINST STORFRONT WINDOWS TO REMAIN INPLACE 12 BASE BID REMOVE CERAMIC TILE, GROUT BED, ENTRANCE MAT AND FRAME - DO NOT DAMAGE SUBSURFACE OR EDGES DEDUCTIVE ALTERNATE CERAMIC TILE TO REMAIN INPLACE ENTRACNCE MAT TO BE REPLACED MAT FRAME TO REMAIN LEGEND PARTITIONS TO BE REMOVED WALLS TO BE REMOVED SYNTHESISLLC THE FUSION OF ARCHITECTUR DESIGN TECHNOLOGY PEOPLE 2353 130th Avenue NE, Sute 202 Bellevue, WA 98005 425869 1946 (Talc) 425 885 6208 Ssk E?ssiQn ISSIE NO. DATE O ENOPED BV• JS Interior Planning & Design PHONE 206236 -7273 FAX 206 236 -1240 rjseeks @aol.com CELL 206 605 -1501 4259 EAST MERCER WAY MERCER ISLAND. WA 98040 REVISIONS D PROFESSIONAL STAMP D ATE• 03/23/2000 PROJECT NU 98009.03:000 _091 ▪ e SECISTE SED I REElT PROJECT INFORMATION KING CO. HOUSING AUTHORITY TENANT IMPROVEMENTS CENTRAL OFFICE 600 Andover Park West Tukwila, WA 98118 SHEET INFORMATION RELEASE FOR ISSUED FOR PERMIT ' TRLE DEMOLITION FLOOR'e PLANS REVEWED BV• APPROVED BY. SHEET NO MAA p{ R 2 4 MR DRAWN in PEi ��� 1 CENTER A2.1 N p I N ' 4I 11 ■ 1, .... 1 . II a 11 I / � I I NW 1, 1, it I I '1 3 TP i; O Y II �i I I ,\ ;i n n TYP 111 \ 'P 6 a a a d � ' d n ii , II ii ii1 F -- . - 1 nL // L—� ii 3 �I II TYP 9 TYP ry ry 3 , TYP ,1 1 1. r , 3 O TYP -T. �r - =ii L J 1 ' i� u „ 1■ u " n 11 0 n 11 ri : \ ° a a a a /� i; I \ !y yI I 1. _ 1 I _ _/ i 12 �, 12 4 .. j / L- ..y t - 3 TYP P s i TYP I O 11 // L -� r _ OTYP i TYP 4 © O IO ' 10 L, ,' ' O I r / \ /TYP NTYP .2e mk. , O \ i� m T Fa I II J OTYP F I L 1' -'1 L�I I I s� 1M J °__ 9P al ih F 1 O L I / MI �._� MA. I , i I � �� L 11 _ __ i 12 .4 ■1111! w li r l # . e 11 111111' O . Jail H OOO 4711111 O <s> NORTH NORTH SECOND FLOOR DEMOLITION PLAN SCALE: 1 /8 " -1' -0" FIRST FLOOR DEMOLITION PLAN GENERAL DEMOLITION NOTES: CONDITIONS MAY VARY FROM THOSE SHOWN. THE CONTRACTOR IS TO'SCHEDULE A BUILDING WALK- THROUGH WITH THE OWNER BEFORE DEMOLITION TO IDENTIFY ITEMS TO BE SALVAGED AND CLARIFY DEMOLITION. THE CONTERACTOR IS TO REMOVE ALL DESIGNATED EQUIPMENT AND RETURN IN ORIGINAL CONDITION TO THE OWNER C. PROTECT PORTIONS OF EXISTING BUILDING OR STRUCTURES, WHICH ARE TO REMAIN, AGAIF"'T DAMAGE OF DISCOLORATION D. PROTECT ANY ITEMS OR EQUIPMENT TO REMAIN AGAINST DAMAGE E. WHERE EXISTING CONDITIONS ARE DEFACED OR MODIFIED DUE TO WORK PERFORMED, THE CONTRACTOR IS TO RESTORE SAME WITH FULL PIECES TO MATCH ADJOINING MATERIAL AND FINISH. REPAIRED FINISHES SHALL BE EXTENDED TO THE NEAREST VISUAL BREAK LINES SUCH AS CORNERS, CEILING LINES, TOP OF BASE AND SIMILAR F. VERIFY RELOCATION OR TERMINATION OF SERVICES IN WALLS OR CEILINGS TO BE REMOVED. COORDINATE WITH MECHANICAL AND ELECTRICAL G_ ADDITIONAL DEMOLITION, NOT DIRECTLY INDICATED HERE MAY BE REQUIRED DEMOLITION PLAN KEYNOTES: THIS AREA N.I.C. OFOI - OWNER TO REMOVE ALL CEILING TILE AND STORE SALVAGEABLE UNITS FOR REUSE IN ROOM 201 - OWNER TO DISPOSE OF SALVAGE: CEILING GRID TO REMAIN INPLACE AND BE REUSED THROUGHOUT ENTIRE BUILDING O OFOI - OWNER TO REMOVE ALL DEMOUNTABLE PARTITIONS AND DEMOUNTABLE DOORS FOR REUSE IN ROOM 201 - OWNER TO DISPOSE OF SALVAGE REMOVE CARPET - INCLUDING STAIRS O REMOVE SHEET VINYL O REMOVE CASEWORK O REMOVE WOOD BASE O REMOVE WOOD TRIM AND HANDRAIL AS REQUIRED FOR NEW CONSTRUCTION DEMOUNTABLE WALL AND DEMOUNTABLE DOOR TO REMAIN INPLACE 10 TILE. FIXTURES, PARTITIONS, AND CASEWORK TO REMAIN INPLACE - PROTECT <> WOOD HANDRAIL AND STAIR EDGING AGAINST STORFRONT WINDOWS TO REMAIN INPLACE 12 BASE BID REMOVE CERAMIC TILE, GROUT BED, ENTRANCE MAT AND FRAME - DO NOT DAMAGE SUBSURFACE OR EDGES DEDUCTIVE ALTERNATE CERAMIC TILE TO REMAIN INPLACE ENTRACNCE MAT TO BE REPLACED MAT FRAME TO REMAIN LEGEND PARTITIONS TO BE REMOVED WALLS TO BE REMOVED SYNTHESISLLC THE FUSION OF ARCHITECTUR DESIGN TECHNOLOGY PEOPLE 2353 130th Avenue NE, Sute 202 Bellevue, WA 98005 425869 1946 (Talc) 425 885 6208 Ssk E?ssiQn ISSIE NO. DATE O ENOPED BV• JS Interior Planning & Design PHONE 206236 -7273 FAX 206 236 -1240 rjseeks @aol.com CELL 206 605 -1501 4259 EAST MERCER WAY MERCER ISLAND. WA 98040 REVISIONS D PROFESSIONAL STAMP D ATE• 03/23/2000 PROJECT NU 98009.03:000 _091 ▪ e SECISTE SED I REElT PROJECT INFORMATION KING CO. HOUSING AUTHORITY TENANT IMPROVEMENTS CENTRAL OFFICE 600 Andover Park West Tukwila, WA 98118 SHEET INFORMATION RELEASE FOR ISSUED FOR PERMIT ' TRLE DEMOLITION FLOOR'e PLANS REVEWED BV• APPROVED BY. SHEET NO MAA p{ R 2 4 MR DRAWN in PEi ��� 1 CENTER A2.1 11 ■ 1, 'I . II a 11 I / � I I OTY ii / / -II -� / q / 1::I \ i r� ; I I \` q it I I '1 3 TP i; O Y II �i I I ,\ ;i n n TYP 111 \ 'P 6 II N �I - _ d � ' d n ii , II ii ii1 F -- . - 1 nL // L—� ii 3 �I II TYP ey L r— L// -11- 3 O TYP -T. �r - =ii L J 1 ' i� u „ 1■ u " n 11 0 n 11 ri : \ !y yI I 1. 7 ,, { I r _ T / O L i \ l 12 T OO 6 ;: s i TYP I O 11 // L -� r _ OTYP i TYP 4 \ O 5 II� NTYP mm Ma !� mk. T Fa I II J OTYP F I L 1' -'1 L�I I I r � ' 1 � j u IL/ II 11 3 � ii TMP i II 3 TY �\ F I / MI �._� MA. I , i I � _ L 11 _ __ i .4 im. _n_ li r l # . e 11 111111' i 4711111 <s> <s> 0<s> 0 NORTH NORTH SECOND FLOOR DEMOLITION PLAN SCALE: 1 /8 " -1' -0" FIRST FLOOR DEMOLITION PLAN GENERAL DEMOLITION NOTES: CONDITIONS MAY VARY FROM THOSE SHOWN. THE CONTRACTOR IS TO'SCHEDULE A BUILDING WALK- THROUGH WITH THE OWNER BEFORE DEMOLITION TO IDENTIFY ITEMS TO BE SALVAGED AND CLARIFY DEMOLITION. THE CONTERACTOR IS TO REMOVE ALL DESIGNATED EQUIPMENT AND RETURN IN ORIGINAL CONDITION TO THE OWNER C. PROTECT PORTIONS OF EXISTING BUILDING OR STRUCTURES, WHICH ARE TO REMAIN, AGAIF"'T DAMAGE OF DISCOLORATION D. PROTECT ANY ITEMS OR EQUIPMENT TO REMAIN AGAINST DAMAGE E. WHERE EXISTING CONDITIONS ARE DEFACED OR MODIFIED DUE TO WORK PERFORMED, THE CONTRACTOR IS TO RESTORE SAME WITH FULL PIECES TO MATCH ADJOINING MATERIAL AND FINISH. REPAIRED FINISHES SHALL BE EXTENDED TO THE NEAREST VISUAL BREAK LINES SUCH AS CORNERS, CEILING LINES, TOP OF BASE AND SIMILAR F. VERIFY RELOCATION OR TERMINATION OF SERVICES IN WALLS OR CEILINGS TO BE REMOVED. COORDINATE WITH MECHANICAL AND ELECTRICAL G_ ADDITIONAL DEMOLITION, NOT DIRECTLY INDICATED HERE MAY BE REQUIRED DEMOLITION PLAN KEYNOTES: THIS AREA N.I.C. OFOI - OWNER TO REMOVE ALL CEILING TILE AND STORE SALVAGEABLE UNITS FOR REUSE IN ROOM 201 - OWNER TO DISPOSE OF SALVAGE: CEILING GRID TO REMAIN INPLACE AND BE REUSED THROUGHOUT ENTIRE BUILDING O OFOI - OWNER TO REMOVE ALL DEMOUNTABLE PARTITIONS AND DEMOUNTABLE DOORS FOR REUSE IN ROOM 201 - OWNER TO DISPOSE OF SALVAGE REMOVE CARPET - INCLUDING STAIRS O REMOVE SHEET VINYL O REMOVE CASEWORK O REMOVE WOOD BASE O REMOVE WOOD TRIM AND HANDRAIL AS REQUIRED FOR NEW CONSTRUCTION DEMOUNTABLE WALL AND DEMOUNTABLE DOOR TO REMAIN INPLACE 10 TILE. FIXTURES, PARTITIONS, AND CASEWORK TO REMAIN INPLACE - PROTECT <> WOOD HANDRAIL AND STAIR EDGING AGAINST STORFRONT WINDOWS TO REMAIN INPLACE 12 BASE BID REMOVE CERAMIC TILE, GROUT BED, ENTRANCE MAT AND FRAME - DO NOT DAMAGE SUBSURFACE OR EDGES DEDUCTIVE ALTERNATE CERAMIC TILE TO REMAIN INPLACE ENTRACNCE MAT TO BE REPLACED MAT FRAME TO REMAIN LEGEND PARTITIONS TO BE REMOVED WALLS TO BE REMOVED SYNTHESISLLC THE FUSION OF ARCHITECTUR DESIGN TECHNOLOGY PEOPLE 2353 130th Avenue NE, Sute 202 Bellevue, WA 98005 425869 1946 (Talc) 425 885 6208 Ssk E?ssiQn ISSIE NO. DATE O ENOPED BV• JS Interior Planning & Design PHONE 206236 -7273 FAX 206 236 -1240 rjseeks @aol.com CELL 206 605 -1501 4259 EAST MERCER WAY MERCER ISLAND. WA 98040 REVISIONS D PROFESSIONAL STAMP D ATE• 03/23/2000 PROJECT NU 98009.03:000 _091 ▪ e SECISTE SED I REElT PROJECT INFORMATION KING CO. HOUSING AUTHORITY TENANT IMPROVEMENTS CENTRAL OFFICE 600 Andover Park West Tukwila, WA 98118 SHEET INFORMATION RELEASE FOR ISSUED FOR PERMIT ' TRLE DEMOLITION FLOOR'e PLANS REVEWED BV• APPROVED BY. SHEET NO MAA p{ R 2 4 MR DRAWN in PEi ��� 1 CENTER A2.1 oFFtca. SPA INFORMATION SERVICES HALL 202 LOBBY ELEC ROOM 231 WOMEN 229 MEN 227 I/A II r! 0 I E1��0 IHI E �� 2301 RENTAL 201 OPFI Q WORK AREA I _ 210 ,o 3' -1 1" MAINTENANCE & CONST. 211 4' -5 1/4" 33' -2 1/4" ASSET MANAGEMENT 219 NORTH NORTH SECOND FLOOR PLAN SCALE: 1/8 " -1' -0" FIRST FLOOR PLAN 0 0 SIM nn FLOOR PLAN KEYNOTES: ' O NO WORK THIS AREA - ROOMS 201 N.I.C. OFOI - REPLACE ALL DAMAGED GLASS (N.I.C.) THROUGHOUT ENTIRE BUILDING REMOVE SILL - CONSTRUCT NEW WALL INSIDE WINDOWS ONTOP OF EXISTING PARTIAL WALL, INSULATE NEW WALL AND PROVIDE BLACKOUT FILM INSIDE WINDOWS REPAIR AND REFINISH EXISTING WOOD TRIM AND HANDRAILS TO MATCH NEW WOOD TRIM REPAIR AND REPAINT ALL EXISTING WOOD WINDOW SILLS THROUGHOUT- TYPICAL OFCI - LAVATORY. SHOWER, FAUCETS, GRAB BARS, MIRROR. AND TOILET ACCESSORIES FOR TOILET ROOM 125 BASE BID PROVIDE CARPET - SEE INTERIOR FINISHES DEDUCTIVE ALTERNATE CERAMIC TILE TO REMAIN INPLACE CLEAN (COMPLETELY) AND REPAIR CRACKED TILE - REPLACE ENTRANCE MAT OFCI - DEMOUNTABLE PARTITIONS AND DOORS TO BE REUSED FROM STORED MATERIALS LOCATED IN ROOM. 201 PROVIDE 1 HR CONSTRUCTION SEPARATION OF THE CORE FROM THE REMAINDER OF THE BUILDING - MAINTAIN AND REPAIR EXISTING 1 HR WALLS ABOVE CEILING PROVIDE 1 HR FIRE SAFING WHERE REQUIRED FOR MECANICAL AND ELECTRICAL PENETATIONS CLOSET 106 PROVIDE'. +7' K & V ADJUSTABLE SHELF BRACKETS AND (6) SHELVES CLOSET 110 - PROVIDE CLOTHES ROD AND FULL. LENGTH. SHELF HANDRAIL ALONG. WINDOWS TO REMAIN INPLACE I REPLACE SUPPORTS W/ 'JULIUS BLUM #892 BRONZE - REFINISH TO MATCH NEW WD TRIM( CORRECTION LTR#_1___ 11 s tn -t)9 SYNTHESISLLC • THE FUSIO 0 .ARCHITECTURE, DESIGN TECHNOLOGY & PEOPLE 2353130th Avenue NE, Suite 202 Bellevue, WA 98005 425 8691946 (fate) 425 885 6208 ISSUE NO. Ssokt Dosign Interior Planning & Design PHONE 206 236 -7273 FAX 206 236 -1240 seeksdesian@homecom CELL 206 605 -1501 4259 EAST MERCER WAY MERCER ISLAND, WA98040 REVISIONS A 04/17/00 ADD DOOR $202 DATE REM PROFESSIONAL ST CITY OETUICNIL n, ++ T I, pP�� APR 2 8 cJ BL PROJECT INFORMATION - KING CO. HOUSING AUTHORITY TENANT IMPROVEMENTS CENTRAL OFFICE 600 Andover Park West Tukwila, WA 98188 SHEET INFORMATION RELEASE FOR. ISSUED FOR BID FLOOR PLANS ammo, BY. JS RENEWED BY. DATE 03/31/2000 SHEET NO PROTECT NO. 98009.03.000 APPROVED BY. RECEIVED CITY OFTUKWIIA PR t -20' PERMIT CENTER ORAwa aY• STAFF A2.2 170' -0 VERIFY / I `�' r ,0 li i _ 4 4 _ 9. o 4 Lk " Z I P 7 © TM I o IF © I WORK ROOM O OFFICE o ®m OFFICE ® © � -H ° _ BREAK dAl w = TOR 107 5' - 5" I - ASST - ,>-_, DIRECTOR 0 © CONFERENCE EXE n 4 � UTIVE _ FFICE I 1 8 EXECUTIVE OFFICE 124 ' - 7 1 /z" I 1s' -o 1/2° FILES ADMINISTRATIVE SERVICES 108 a 1 ,17/ l 6 -,9 „9 — .6 118 118A i. © 7 - 1 a TYP 109 CLOSET N III II I . _ II • LO 108 W - TYP 123 El 107 CLOSET HALL 110 11 88 E rn OFFICE o 711 - - /2" _ _ 106 _0 � i 10 i 1 - a. 5 —o" 114 14 116 122 fO 123 OFFICE te- I TOILET • © -1 I ^ 2 13 " ° j09 r © 5 _4 .7 - 1 1/4 1 - 1" �-s, 119 1 1 9 -r-I ry X .` - 121 I ® w �' 1 re 0 RESIDENT 4' - 9 1 If WM -. -- -- 1 0 1 _ _ _ e TELE 138 TIP t 0 i ^ I TYP I Q n „o —,z I © Tv - n E� } - r CONF. I '� �4'- 0 °' -4 127B In d.0 SEI'WES °o 7 ' 3 -I © 4' - 4 1/2" 4' 0" ;-L I I _ 0 O 0 HALL 39 O7 a 139 120 TY 120 N e 3 I 5' - 4 • STAI I ' - � I 72 i iv� LI © ALIGN ,. 3 - e ©HALL 2' -8 6 / = N �� STORA - �� it a - - ` CONF. �fT 1oa - Ty P N o , �S 3 / ' � 1 I _ LOBB 100 a , ELEC ROOM 14 '�' 4 HAL © du �. i R, I ._ ► � o• I I' WOMEN O MEN 140 O �► p o _ ' 4 � _ -I H OUSING - ' , 126 13 4' - to 3/4" m 1'8 142 .o ° D 0° 10. 0 " i MANAGEMENT B 1 32 10 3_ 1 DIR I 1_y ®TM i �, i 03 I / © - - _I- -- - - -- II I I I I HUMAN M O8 HM A DIRECTOR PURCHASING [ " ' CTOR n 103 COMM . HM C = 13. A I I o 7 _ 131 0 130 °O 129 137 OFFICE OFFICE OFFICE o la �' ® HT. II P ,z —,s RESOURCES I / I� 1�■�!I�+� t ' LQ. •�� \Ip, ® 102 Iu 5 '! �� ' ¢ . e TAIR143 � MECH f' ROOM 141 i 135 134 133 _ P - _ ni '1'I' I •o••�= p II \® \IF V / mar ® © ►,[�� SIM / ® .GY' SIM SIM ;O � - WP � � ' Q I I e. ; , o ;; I; I r _.4 !_4IJ S I - - - -- I 8' -3 3/4 ". 10 1 1/2" 10' -1 1/2" 10' -1 1/2" 9' -3 /4" VERIFY 20' -2" VERIFY 1 - . oFFtca. SPA INFORMATION SERVICES HALL 202 LOBBY ELEC ROOM 231 WOMEN 229 MEN 227 I/A II r! 0 I E1��0 IHI E �� 2301 RENTAL 201 OPFI Q WORK AREA I _ 210 ,o 3' -1 1" MAINTENANCE & CONST. 211 4' -5 1/4" 33' -2 1/4" ASSET MANAGEMENT 219 NORTH NORTH SECOND FLOOR PLAN SCALE: 1/8 " -1' -0" FIRST FLOOR PLAN 0 0 SIM nn FLOOR PLAN KEYNOTES: ' O NO WORK THIS AREA - ROOMS 201 N.I.C. OFOI - REPLACE ALL DAMAGED GLASS (N.I.C.) THROUGHOUT ENTIRE BUILDING REMOVE SILL - CONSTRUCT NEW WALL INSIDE WINDOWS ONTOP OF EXISTING PARTIAL WALL, INSULATE NEW WALL AND PROVIDE BLACKOUT FILM INSIDE WINDOWS REPAIR AND REFINISH EXISTING WOOD TRIM AND HANDRAILS TO MATCH NEW WOOD TRIM REPAIR AND REPAINT ALL EXISTING WOOD WINDOW SILLS THROUGHOUT- TYPICAL OFCI - LAVATORY. SHOWER, FAUCETS, GRAB BARS, MIRROR. AND TOILET ACCESSORIES FOR TOILET ROOM 125 BASE BID PROVIDE CARPET - SEE INTERIOR FINISHES DEDUCTIVE ALTERNATE CERAMIC TILE TO REMAIN INPLACE CLEAN (COMPLETELY) AND REPAIR CRACKED TILE - REPLACE ENTRANCE MAT OFCI - DEMOUNTABLE PARTITIONS AND DOORS TO BE REUSED FROM STORED MATERIALS LOCATED IN ROOM. 201 PROVIDE 1 HR CONSTRUCTION SEPARATION OF THE CORE FROM THE REMAINDER OF THE BUILDING - MAINTAIN AND REPAIR EXISTING 1 HR WALLS ABOVE CEILING PROVIDE 1 HR FIRE SAFING WHERE REQUIRED FOR MECANICAL AND ELECTRICAL PENETATIONS CLOSET 106 PROVIDE'. +7' K & V ADJUSTABLE SHELF BRACKETS AND (6) SHELVES CLOSET 110 - PROVIDE CLOTHES ROD AND FULL. LENGTH. SHELF HANDRAIL ALONG. WINDOWS TO REMAIN INPLACE I REPLACE SUPPORTS W/ 'JULIUS BLUM #892 BRONZE - REFINISH TO MATCH NEW WD TRIM( CORRECTION LTR#_1___ 11 s tn -t)9 SYNTHESISLLC • THE FUSIO 0 .ARCHITECTURE, DESIGN TECHNOLOGY & PEOPLE 2353130th Avenue NE, Suite 202 Bellevue, WA 98005 425 8691946 (fate) 425 885 6208 ISSUE NO. Ssokt Dosign Interior Planning & Design PHONE 206 236 -7273 FAX 206 236 -1240 seeksdesian@homecom CELL 206 605 -1501 4259 EAST MERCER WAY MERCER ISLAND, WA98040 REVISIONS A 04/17/00 ADD DOOR $202 DATE REM PROFESSIONAL ST CITY OETUICNIL n, ++ T I, pP�� APR 2 8 cJ BL PROJECT INFORMATION - KING CO. HOUSING AUTHORITY TENANT IMPROVEMENTS CENTRAL OFFICE 600 Andover Park West Tukwila, WA 98188 SHEET INFORMATION RELEASE FOR. ISSUED FOR BID FLOOR PLANS ammo, BY. JS RENEWED BY. DATE 03/31/2000 SHEET NO PROTECT NO. 98009.03.000 APPROVED BY. RECEIVED CITY OFTUKWIIA PR t -20' PERMIT CENTER ORAwa aY• STAFF A2.2 INFORMATION SERVICES 208 OPE! OFFICI 20` Y v 170' -0" VERIFY 574' -0" VERIFY Q All AI &I 121 AX w NV 4 • w I © WORK ROOM I © OFFICE o I f - R ri �_� 1 1 , 1 7 Ii _ 9 - TOR - T- • 0 Tr• OFFICE _ I BREA - 1' -s yP MAINTENANE � n .l CONFERENCE ' ADMINISTRATIVE SERVICES = i 124 s' - 7 1/2' `'� �c V') 1 4' - 7" INFORMATION SERVICES 'F I DIR CTOR & CONST. 7 109 CLOSET • ts 0 1 /z FILES 114 _ N 206 3 _ OFFICE 211 „e /< < -,zz • CI Ty 212 t CLOSET 208 OPEN TYP Juan UTIVE FFICE _I : 122 ° OFFICE TYP 208 207 4 7" 11' -0 1/: 4'-11 / 4• -7• 205 2 -9 1/2" it' -11 5/8" r rn OFFICE h 19 119 I & ii 'I'. M TYP RENTAL , '� s � C ` �' H _ , � �� ALIGN 1 ,�I IIIIK 5' r 1/4 1 1 o WORK AREA © 4 _ _ A5. J ^ � � ryry 121 2 - 2ALL 02 TYP OFFICE �, •y 1 _ 210 N� _ ���� 1/ alA 1 1 _ 204 3I ALIGN O © HALL .. �� 23 2 2 I HALL TYP I © 1 OM , I \ 204 -ALIGN \ COL. , \ © GN _ 7 1. 7 q TYP 21 MINI „0 ( I I s I w Q 226 0 ' I i, TYP ALIGN 203 ) �� I '- ', 4 4'- zz2 CONE TYP 222 HALL 2O9 ® WORK , �,, /¢ nva CI 1 _,,,c J Ol Q a csj 2 Y 0 3 ZZ / ` " ' T� I I I I I LOBBY 200 �� 0 ELEC ROOM 231 • ■ 1 1� _ T rP ;WAITING ! jE 2241 u am mat MEI ∎ _ ■ ■ ■ lim WOMEN z r w � 11 C AREA 220 3 I ALIGN ° 1/4" _ / 33 -2 1/4 a , 7 © = TYP ,„ - . ^ LOBBY m 100 ° �� 229 H ALL � .1 1 15 © 2219 TrP 4' - 5 _DEVELOPMENT -77 216 N M I © I LOUNGE DIRECTOR 8' 7" Illlllllllll • ELEC ROOM 144 _. 1 1 Y Y11W 3' 11" ASSET '° 4' -8 3/4" 216 �■ - / � 1 ♦ i o`� i �TYP ; ;eotA � � MEN 140 I a ° 4 _ } ;I 'r MANAGEMENT 219 HOUSING 2i D °I ^ N �r �� TYP -. ,,30. 126 1 4' - 10 3/4" 221 1 _ 1 m I � = � I 223 1 I Q 1 1 �np �_ s i _ L n M 4. -O. to' -o" i MANAGEMENT B DIRECTOR N 132 to' - 7Q 3 � ) RENTAL I + 1 � DIR OOF211 217 �I, 201 I IO .' F��O M - © ■ - - -- ' h � I HUMAN 11 RESOURCES j II L— L � ii , 228 t � ; � � : ii i �- HM A 103 H TYP ; ,.t �. �yI IIII trim sz3o COMM. 137 II i � � M m 13 0 p ° Q TYPI I � 129 S wil � ©' 1� 0 0 1 2 I IIE�� 11 •:ra- Y v 170' -0" VERIFY _ Q Lk w Lk Lk ,_._ 1 !� w Lk Ak w w w NV 4 • w I © WORK ROOM I © OFFICE o I f - R ri �_� 1 1 , 1 7 I .I 01 II -�IM1 I TOILET 9 - TOR - T- • 0 Tr• OFFICE _ I BREA - 1' -s 107 DIRECTOR � n .l CONFERENCE ' ADMINISTRATIVE SERVICES EXECUTIVE OFFICE 124 s' - 7 1/2' 5 _5 +I 1 08 ° 118A 118B __ © T - t ' ° to 7 109 CLOSET • ts 0 1 /z FILES 114 N 7 [ •- o �� TYP 123 4 123 t CLOSET 1 10 EXE ` UTIVE FFICE _I : 122 ° I•y II I qI- /z " ^ - - ^I 106 b HALL 101 ' 116 r rn OFFICE h 19 119 .I 0125 i © I 0D I 2 4' -9 1 • 5 0" I ' 3 ° 109 5' r 1/4 1 1 OFFICE - - _L I ° T o i TYP 4 _ _ A5. J ^ � � ryry 121 2 - r' o �, . ' ,� I W -1 ' �I__- _ 'n •� 138__ '+- i Oi 139 TYP I © 1 OM , I \ T W r\ o CONF. a 120 I TYP - �" 1L- 72 ( I I s I w RESIDENT S VI o - 101 - /1 _TELE '- ', 4 4'- 0 " ,' -4 1276 STAI' - 1 2 ° u 105 a �I 4' 1/2 1 HALL 139 © ® //1 5 - 4 / 4' - 0" i e I Q' ; 1 l — 1� / a I - . ^ LOBBY m 100 ° �� H ALL � .1 1 15 © - , © ALIGN � © ® 3 / N � ■. = l !■ III ■ - CONF. 104 N TYP / \ o l / � 0 / � � I ELEC ROOM 144 _. 1 1 Y Y11W ® HALF �.. 8" 2 ' - • 12 6 , STORAGE _ - / � 1 ♦ i o`� i WOMEN MEN 140 I a ° 4 _ } ;I 'r HOUSING ,,30. 126 1 4' - 10 3/4" o 1 '8 M MN mu � I "r 142 • o ; a n M 4. -O. to' -o" i MANAGEMENT B roa � N 132 to' - 7Q 3 s I 1 • - -7 " .. TYP J DIRECTOR © PURCHASING ,, : =IF �=II MI. �■ '� 0 1 � DIR 103 I I , CTOR ` 1 i E 1 - t n -® 1• - © ■ - - -- ' h � I HUMAN 11 RESOURCES j II I s. HM° - C 13 m Nn OFFICE a n 0 OFFICE M r� HM A 103 H TYP m: o I O 111111 q COMM. 137 0 OFFICE 131 m 13 0 p ° Q TYPI I � 129 S wil � ©' _ - s 102 lu —I� 0 ■■ IIE�� 11 •:ra- �� • 0 TM_ 135 � 134' w OSIM 1.0' -1 1/2" 133 � ,_. ` w 1; ■Ilu■It ROOM ' VIVA Irk 14 I �► • \/ An A1 T �SIM II \i \P %V Lk W I °O �\ �,� S 0 1 1/2_� 10' -1 1/2" SI 9' -3 /4" VERIFY 20' -2" VERIFY � I 8' - 3/4" . I NORTH NORTH SECOND FLOOR PLAN SCALE: 1/8"=1' -0" FIRST FLOOR PLAN SCALE: 1/8 " =1' -0" 00 FLOOR PLAN KEYNOTES: NO WORK THIS AREA - ROOMS 201 N.I.C. OFOI - REPLACE ALL DAMAGED GLASS (N.I.C.) THROUGHOUT ENTIRE BUILDING REMOVE SILL - CONSTRUCTS NEW WALL INSIDE WINDOWS ONTOP OF EXISTING PARTIAL WALL, INSULATE NEW WALL AND PROVIDE BLACKOUT FILM INSIDE WINDOWS REPAIR AND REFINISH EXISTING WOOD TRIM AND HANDRAILS TO MATCH NEW WOOD TRIM REPAIR AND REPAINT ALL EXISTING WOOD WINDOW. SILLS THROUGHOUT- TYPICAL OFCI - LAVATORY, SHOWER, FAUCETS, GRAB BARS, MIRROR. AND TOILET ACCESSORIES FOR TOILET ROOM 125 BASE BID PROVIDE CARPET - SEE INTERIOR FINISHES DEDUCTIVE ALTERNATE CERAMIC TILE TO REMAIN INPLACE CLEAN (COMPLETELY) AND REPAIR CRACKED TILE - REPLACE ENTRANCE MAT OFCI DEMOUNTABLE PARTITIONS AND DOORS TO BE REUSED FROM STORED MATERIALS LOCATED IN ROOM 201 PROVIDE 1 HR CONSTRUCTION SEPARATION OF THE CORE FROM THE REMAINDER OF THE BUILDING - MAINTAIN AND REPAIR EXISTING 1 HR WALLS ABOVE CEILING PROVIDE 1 HR FIRE SAFING WHERE REQUIRED FOR MECANICAL AND ELECTRICAL PENETATIONS CLOSET 106 PROVIDE +7' K & V ADJUSTABLE SHELF BRACKETS AND (6) SHELVES CLOSET 110 PROVIDE CLOTHES ROD AND FULL LENGTH SHELF HANDRAIL ALONG WINDOWS TO REMAIN INPLACE / REPLACE SUPPORTS W/ 'JULIUS BLUM' #692 BRONZE - REFINISH TO MATCH NEW WD TRIM CORRECTION 1 Rit t £ I D 2OOO oi SYNTHESISLLC THE FUSION OF ARCHITECTURE, DESIGN TECHNOLOGY & PEOPLE 23531s Avenue NE, Sulam 202 Bellevue, WA 98005 425 8691946 (fax) 425 885 6208 ISSUE NO. DATE. SEEDS ?siqn CITYOFTU F( APO APR 2 5 Interior Planning & Design PHONE 206 236 -7273 FAX 206 236 -1240 seeksdesign @home com CELL 206 605 -1501 4259 EAST MERCER WAY MERCER ISLAND, WA 98040 REVISIONS Q l 04/17/OD ADD DOOR #202 DATE PROFESSIONAL STAMP PROJECT INFORMATION KING CO. HOUSING AUTHORITY TENANT IMPROVEMENTS CENTRAL OFFICE 600 Andover Park West Tukwila, WA 98188 SHEET INFORMATION ....As.... ISSUED FOR BID RnE FLOOR PLANS DESIGNED BY. JS DRAWN BY.. STAFF RENEWED BY. APPROVED SY. 03/31/2000 SNEET NO PROJECT No. 98009.03.000 ... RECEIVED . CRY OFTUKWILA 1 8 •4UP PERMIT CENTER A2.2 DOOR /OPENING SCHEDULE DOCKS "OP` NING`' FRAMES DETAILS REMARKS NC E DOOR SIZE THK MATL GL LABEL HDW FIN TYPE MTL FIN HD JAMB SILL 1009 - -- - -- - -- - -- - -- - -- OFq - -- - -- - -- - -- -- - -- -- NOTE 13 '... 1000 F 3' -0 x 7' -0` 1 3/4" WD 1 HR /SAFE 1 HR OFCI SV 2 SIL PNT 9, 14//92 5, 4/A9.2 14/A9.2 NOTE 15 101 F 3' -0 x 7' -0 1 3/4° WD --- -- OF l SV 1 WD W 12/A9.2 12/A9.2 .. - -- 102/ F 3' -0 x 7' -0 1 3/4` --- --- gig � a � 1 12//92 12//9.2 --- 1020 - -- AS PER OPENING - -- - -- 1 HR - -- 14/A9.1 17/A9.1 14/A9.1 ROUJNG COUNTER FIRE SHUTTER 103 F 3' -0 x 7' -0" 1 3/4" SAFETY - -- 2 3, 13/A9.2 2, 12/A9.2 3/A92 104 F 3' -O x 7' -0" 1 3/4" WD SAEEIY -- UFa SV 4 WD SV 3, 13/A9.2 2. R,12/A9.2 3, 7/A9.2 105 F 3' -0 x 7' -0" 1 3/4" WD SAFETY - -- OM SV 2 WD SV 3, 13/A92 2. 12/A9.2 3/A9.2. 106 F 3' -0" x 7' -0' 1 3/4 WD - -- - -- OM SV 1 WD SV 12/A92 12/A9.2 - -- 107 F 3' -0 x 7' -0' 1 3/4° WD SAFETY - -- OM SV 3 WD SV 3, 13/A9.2 2, 8. 12/A9.2 3, 7/A9.2. 108 F 3' -0 z 7' -0" 1 3/4° WD SAFETY - -- OM SV 3 SW WD SV 3, 13/Al2 2, 8, 12/A9.2 3, 7/A9.2 ADD (1) UPPER REUTE BAY - AS PER PLAN A2.2 109 F 3' -0 x 7' -0" 1 3/4". WD SAFETY - -- OFCI SV 6 WD SV 3, 13/A9.2 2, 8. 12/A9.2 3, 7/A9.2 113 F 3' -0" x 7' -O' 1 3/4" WD - -- - -- OEt SV 1 WD SV 12/A9.2 12/A9.2 - -- 717 F 3' -0 x 7' -0 1 3/4" WD SAFETY - -- OR2 SV 4 WD SV 3. 131/9.2 2, 8, 12/A92 3, 7/A9.2 1184 F 3' -0 x 7' -0" 1 3/4" f1D SAFETY' - -- 0FC1 W 4 WD SV 3, 13/A9.2 2, 8, 12/A92 3, 7/A9.2 1180 - -- -- -- -- SAFETY. --- --- --- 9 WD SV 13/A92 2, 8/A9.2 7/99.2 119 F 3' -0 x 7' -0" 1 3/4' WD SAFETY - -- 9972 SV 4 WD SV 3. 13/99.2 2, 8, 12/A9.2 3. 7/A9.2 120 F 3' -0" x 7-0" 1 3/4" WD SAFETY - -- OFG SV 4 WD 9f 3. 13/A92 2, 8, 12/A92 3. 7/A9.2 122 F 3' -0 x 7' -0 1 3/4" WD SAFELY - -- OFCI SV 4 WD SV 3. 13/992 ........ Z 8. 12/A92 3. 7/A9.2 _ _... 123 F 3' -0 x 7-0" 1 3/4" VA SAFETY - -- OFCI SV 4 VA SV 3, 13//9.2 2, 8. 12/99.2 3, 7/A9.2 124 F /1 -R 3' -0 x 7 -0" 13/4" WD SAFETY - -- OFG SV 2 WD SV 3, 13/99.2 2, 12/992 3/A9.2 RELITE 18 DOOR: 10 " - X 24" 125 f 3' -0 x 7' -0 1 3/4° WD - -- --- 9993 SV 7 WD SV 12//9.2 12//9.2 --- 126 --- - -- - -- - -- SAFETY --- - - -. --- 7 WD N 13//92 2//92 7//9.2 127A F - -- - -- WD - -- --- ORII SV --- WD SV - -- -- - -- NOTE /2 1278 - -- --- - -- - -- --- -- 0E01 - -- - - - -- - -- - -- - - -.. - -- HOTE /3 128 F 3' -0 z 7' -0" 1 3/4" WO - -- - -- OFCI SV 1 WD SV 12//92 12//9.2 - -- 730/ F 3' -O" x 7' -0" 1 3/4" WD SAFETY ' --- OFa SV 2 ND SV 3, 73//92 2, 12/992 3/992 1309 --- - -- - -- --- SAFETY - -- - -- - -- 10 YD " 13/99.2 2, 8//9.2 7/A92 133 F. 3'x 7' APPROXIMATE -- WO -- --- OFG SV 1 WD 9..' -'- - - -. - - -. NOTE /4. 134 F 3'x 7' APPROXIMATE -- 1L19 --- -- OFa SV 1 WD SR - -- -- ---. NOTE /4. 135 F 3'x 7' APPROXIMATE --- HO -- --- OFq SV 1 WD SV -- -- -- NOTE /4. 137 F 3' -0 z 7' -0" I 3/4" WO SAFETY - -- fOFG SR 2 WD SV 3, 13/992 2, 12//92 3//9.2 WO - -- - -- ma SV - -- w0 SV - -- - -- - -- NOTE / 139 F 3' -0" x 7' -0` 1 3/4" WD - -- I HR OFq SV 1 SR PHI 4/A9.2 4/A92 - -- NOTE /5 YID -- - -- OFG SV --- WD SV -- --- --- NOTE /2 141 F --- - -- WD --- --- 0E01 SV --- WD SV --- --- - -- NOTE /2 142 F --- --- WD --- --- OF01 SV --- WD SV --- --- --- NOTE /2 144 F - -- --- WD - -- -- 0E0! SV - -- WD SV - -- -- --- NOTE /2 201/ F 3' -0 x 7' -0 1 3/4" SIL - -- 1 HR OFCI PAT 2 SR PAT . 14/992 4/A92 - -- ROTE /5 WD ___ ___ 0E01 SV -__ SIL PNI - -_ ___ ___ NOTE /2 204 - -- --- --- - -- SAFE(Y - -- -- -- 8 WD SV 13/992 2. 8//92 7//92 205 F 3' -0 x 7' -0` 1 3/4' WD SAFELY - -- OF 9V 2 WD SV 3, 13//92 2, 12//92 3//92 206 F 3' -0 x 7' -0" 1 3/4` WO SAFETY - -- 0F12 SV 2 WO SV 3, 13//92 2, 12/992 3/992 208 F 3' -0 x 7. -0" i 3/4" WD - -- - -- OFG SV I WD SV 12/A92 12/A92, - -- 212 F 3' -0" x 7' -0 1 3/4" WD SAFETY - -- OFC1 SR 4 WD SV 3. 13//92 2, 8. 12/A92 3, 7/A92 213 F 3' -0 x 7' -0" 1 3/4" WD SAFETY - -- OF13 SV 4 WD SV 3, 13/99.2 2, 8. 12/A92 3, 7/A92 214 F -- - -- WD - -- -- OM SV - -- ND SV -- -- - -- 1107E /2 216 - -- -- -- - -- SAFETY - -- - -- - -- 9 WD SV 13//92 2. 8/992 7/992 217 F 3' -0 x 7-0" 1 3/4` WD SAFETY - -- OFCI SV 2 WD SV 3, 13//92 2, 12//9.2 3/992 218 F 3'x 7' APPROXIMATE - -- WD -- -- OFCI SV 1 WD SV -- -- - - -. NOTE 14. 221A F 3' -0 x 7' -0` 1 3/4° WD SAFETY - -- oFC SV 2 WD SV 3, 13//92 2, 12/99.2 3/942 2218 - -- - -- -- - -- SAFETY - -- -- -- 9 WO SV 13//92 2, 8//92 7//92 222 F 3' -0 x 7' -0" 1 3/4" HD - -- -- SV 5 WD SV 3, 13/A92 2. R, 12/A9.2 3, 7/92 223 - -- - -- SAFETY - -- - -- - -- 11 WD SV 13/A92 2, 8/892 7/A9.2 224 f 3' -0 x 7' -0` 1 3%4" WD SAFETY - -- OFG SV 2 WD SV 3, 13//92 2, 12//92 3//92 226 F 3' -0 x 7' -0° 1 3/4` WD - -- 1 HR OFq SV 1 SR PFT 4//92 4//92 - -- NOTE /5 227 F --- - -- WD --- -- OM SV -- WD SV -- - -- -- NOTE /2 228 F --- - -- ND --- - -- OFG SV --- WD SV --- - -- - -- NOTE /2 229 F - -- - -- WD - -- - -- OFC SV - -- WD SV - -- - -- - -- NOTE /2 231 F -- --- WD - -- - -- OF01 SV --- WD SV --- --- - -- NOTE /2 232 F, F --- --- WO - -- -- OF01 SV --- WO SV --- --- --- NOTE /2 GENERAL DOOR NOTES: A. NOTATION OF DOORS F DENOTES SINGLE DOOR F,F DENOTES PAIR OF DOORS. B. EXIT DOORS, IN FIREMODE, SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR AN SPECIAL KNOWLEDGE OR EFFORT. C. PROVIDE HANDICAPPED HARDWARE PER UNIFORM BUILDING CODE AND FEDERAL ACCESSIBILITY STANDARD. D. PROVIDE POSITIVE LATCHING HARDWARE ON ALL DOORS. DOOR /RELITE SCHEDULE NOTES: EXISTING DOOR TO REMAIN. SECURITY SYSTEM HARDWARE - OFCI EXEE FROM ROOM 201 RESTRICTED EXCEPT IN FIREMODE DOOR ALSO ALARMED IF OPENED 2. EXISTING DOOR TO REMAIN, OF01 - HARDWARE UPGRADES. CFCI - REFINISH DOOR AND FRAME TO MATCH NEW DOORS 3. EXISTING STOREFRONT DOOR - MODIFICATIONS NIC OFOI - REFINISH FRAMES, REINSTALL.. OF REFURBUSH HARDWARE INSTALL CARD READER SECURITY LATCH SYSTEM 4. OFCI - EXISTING DOOR, FRAME, AND HARDWARE TO BE SELECTED AND REUSED FROM EXISTING DEMOUNTABLE PANEL SYSTEM CFCI - REFINISH DOOR AND FRAME TO MATCH NEW DOORS 5. OFCI - SECURITY CONTROL SYSTEM HARDWARE: SWING FREE CLOSER AND ELECTRONIC LATCH ACTIVATED BY REMOTE CONTROL FROM ROOM 102 (CLOSER ALSO ACTIVATED IN FIREMGDE) 6. 10 ° X 24 REUTE IN DOOR WOOD STOP GLASS IN DOOR WALL TYPES SCALE: 3/4 =1' -U 7 8 0 DOOR & FRAME TYPES EXISTING FLOOR El 3 1/2 METAL OR WOOD STUDS 0 16' OC WITH 5/8", TYPE 'IC. GWB ON EACH SIRE - 1 HR CONSTRUCTION EXISTING CEIUNG ID 3 1/2" METAL OR WOOD STUDS 0 16" DC WITH 5/8" GWB EACH SIDE PROVIDE 7 1/4" WOOD STUDS AT PLUMBING WALL BRACE AS REQUIRED TO STRUCTURE ABOVE EXSTING 1 FIR CONSTRUCTION ABOVE I.:EtiNG FIRESAFE OR TAPE AS REQUIRED FOR 1 HR CONSTRUCTION CEILING PER FINISH SCHEDULE 2 1/2° SOUND BATT INSULATION GWB EA SAE OF S.UDS SILL - WOOD OR MR BRACE AS REQUIRED TO STRUCTURE ABOVE 9 2 1/2 SOUND BAIT INSULATION GWB EA SIDE OF STUDS SILL - WOOD OR MR EXISTING SLAB ON GRADE NOTE 10 SEE DTL 1/992. FOR LOCATION OF 1/8" REVEILS IN WO FRAMES - TYPICAL O q 60% FROSTED SAFETY GLASS (ALL OTHER GLASS TO BE SAFETY, CLEAR) 11 BRACE AS REQUIRED TO STRUCTURE ABOVE CEIUNG PER FINISH SCHEDULE GWB EA SIDE OF STUDS 2 1/2 ° ' SOUND BATT INSULATION SILL - WOOD OR MTL EXISTING FLOOR El 3 /2 METAL OR WOOD STUDS N 16 OC WITH 5/8' GWB - EACH SIDE ® SAME AS D. PROVIDE SOUND BATT INSULATION AT ALL WALL LOCATIONS WHERE A ROOM IS ENCLOSED AND HAS A DOOR BOIL0NG 1 SYN. THESISLLC THE FUSION o F ARCHITECTURE: DESIGN TECHNOLOGY t`£ PEOPLE 2353 130th Avenue NE, sae 202 Bef(evue, WA 98005 425 8691946 (fax) 425 8856208 Ssk S IQfl Interior Planning & Design PHONE 206 236 -7273 FAX 206 236 -1240 rjseeks @aol.Gom CELL 206 605 -1501 4259 EAST MERCER WAY MERCER ISLAND, WA 98040 REVISIONS D2000 -091 DATE REM PROFESSIONAL STAMP _PROJECT :INFORMATION KING CO. HOUSING AUTHORITY TENANT IMPROVEMENTS CENTRAL OFFICE 600 Andover Park West Tukwila, WA 98118 SHEET INFORMATION RELEASE Fop. ISSUED FOR PERMIT TITLE. DESIDrED eY. JS RENEWED BY. CRY TUOR . DOOR SCHEDULE MAR 2 a tail'. Sc WALL TYPES DATE. 03/23/2000 SHEET NO PROJECT Na 98009.03.000 DRAWN 5Y. STAFF APm ovm SY. PERMIT CENTER A3.1 www.synthesisllc.com ROOM FINISH SCHEDULE NO. NAME FLOOR BASE WALLS CEILING REMARKS MTL FIN MTL NORTH EAST SOUTH WEST MTh MTL FIN MTh FIN : MTL FIN MTL FIN 100 LOBBY CONC CPT WOOD GWB PNT GWB PNT GWB PNT GWB PNT ACP /GWB g' -0" SEE SHEET 02 -3 FOR CARPET DESIGN SEE SHEET 1D12 FOR PAINT COLOR LOCATION .. 101 HALL CONC CPT WOOD GWB PNT GWB PNT : GWB PNT GWB PNT ACP 9' -0" SEE SHEET 02.2 FOR CARPET DESIGN 102 HUMAN RESOURCES CONC CPT R8 GWB. PNT GWB PNT GWB PNT GWB PNT ACP 9' -0".. 103 DIRECTOR CONC CPT RB GWB : PNT GWB PNT GWB PNT GWB PNT ACP 9' -0 104 CONFERENCE CONC CPT R8 GWB PNT GWB PNT GWB PNT GWB PNT ACP 9' -0 SEE SHEET ID2.2 FOR CARPET DESIGN 105 RESIDENT SERVICES CONC CPT R8 GWB PNT GWB PNT GWB PNT GWB PNT ACP 9' -O SEE SHEET 02 -2 FOR CARPET DESIGN SEE SHEET 02.2 FOR PANT COLOR LOCATION 106 CLOSET CONC CPT R8 GWB PNT GWB PNT GWB PNT GWB PNT ACP 9' -0" - 107 DIRECTOR CONC CPT RB GWB PNT GWB PNT GWB PNT GWB PNT ACP 9' -0 108 ASST. DIRECTOR CONC CPT RB GWB PNT GWB PNT GWB PNT GWB PNT ACP 9' -0" 109 CONFERENCE CONC 1:03=1. 112:21E211 CPT WOOD GWB PNT GWB PNT. GWB PNT GWB PNT ACP 9' -0" SEE SHEET 102.2 FOR CARPET DESIGN RB GWB PNT GWB PNT GWB PNT GWB PNT ACP 9' -0" CLOSET RB OWN PNT : GWB PNT GWB PNT GWB PNT ACP 9' -0" ® WORK ROOM 114 FILES CONC CPT R8 GWB PNT GWB PNT GWB PNT GWB PNT ACP 9' -0" CFCI - CARPET PLYWOOD FLOOR AND RAMP FOR ROLLING FILES ( OF01 RAMP AND PLYWOOD FLOOR FOR ROLLING FILES ) 115 HALL CONC CPT RB GWB PNT GWB PNT GWB PNT' GWB PNT ACP 9' -O SEE SHEET 102.2 FOR CARPET DESIGN SEE SHEET ID2.2 FOR PANT COLOR LOCATION 116 ADMINL SERVICES CONC CPT RB OWN PNT GWB PNT GWB PNT GWB. PNT ACP R' -0" SEE SHEET 02,2 FOR CARPET DESIGN SEE SHEET 1D2.2 FOR PAINT COLOR LOCATION 117 OFFICE CONC CPT RB GWB PNT GWB PNT GWB PNT GWB PNT ACP 9' -0 118 OFFICE CONC CPT. RB GWB... .... PNT ..GWB.... _ PNT ....GWB ..._.PNT _.. GWB _..PNT.. ACP._.. 9'- 0 " _........ _.. 119 OFFICE CONC CPT RB OWN PNT GWB PNT GWB PNT GWB PNT ACP 9' -O" 120 CONFERENCE CONC CPT WOOD OWN PNT GWB PNT GWB PNT GWB PNT ACP 9' -0" SEE SHEET 02,3 FOR CARPET DESIGN SEE THEET 1D2.2 FOR PAINT COLOR LOCATION 121 OFFICE CONC CPT R8 OWN PNT GWB PNT GWB PNT GWB PNT ACP 9' -0" SEE SHEET ID2.2 FOR CARPET DESIGN SEE SHEET 102.2 FOR PAINT COLOR LOCATION ® EXEC. OFFICE Emizig 'MIMI RB GWB PNT OWN PNT GWB PNT GWB PNT GWB 8' -6 RB OWN PNT GW8 : PNT GWEL PNT GWB PNT ACP 9' -0' ® EXEC. OFFICE mom BREAK ROOM MIME RB GW8 PNT OWN :. PNT OWN PNT GWB PNT ACP 9 ° -O 125 TOILET CONC SV SV OWN PNT GWB PNT GWB PNT GWB PNT, ACP 9 -0" SELF COVED VINYL BASE - HEAT WELD SHEET VINYL SEAMS.. 126 HALL CONC EM /CPT R8 OWB PNT GWB PNT' GWB PNT ,GWB PNT ACP 9' -0" SEE SHEET 02.2 FOR CARPET DESIGN SEE SHEET 102.2 FOR PAINT COLOR LOCATION 127 STAIR CONC EM /CPT RB GWB PNT GWB PNT GW8:' PNT GWB PNT ACP 9 SHT ID22 FOR CARPET DESIGN & PAINT COLOR LOCATION / CARPET STAIRS / ENTRY MAT LOWER LANDING- EXTEND INTO 126. 128 STORAGE : CONC CPT RB GWB PNT OWN PNT GWB PNT GWB PNT ACP 9' -0 ° ' 129 PURCHASING CONC CPT R8 GWB PNT OWN '' PNT GWB PNT GWB PNT ACP 9' -0" 130 DIRECTOR CONC CPT R8 GWB PNT GWB PNT GWB PNT GW8 PNT ACP 9' -0 131 HOUSING MOM'T A CONC CPT RB GWB ' PNT OWN PNT GWB , PNT GWB PNT ACP 9' -O" SEE SHEET IB22 FOR CARPET DESIGN CFCI -. PAINT VINYL COVERED WALLS OF DEMOUNTABLE PARTITIONS 132 HOUSING MGM7 8 CONC CPT R8 OWN PNT OWB PNT GWB PNT GWB. PNT ACP 9' -0" CFCI - PAINT VINYL COVERED WALLS OF DEMOUNTABLE PARTITIONS SEE SHEET 1D2.2 FOR CARPET DESIGN. 133 OFFICE CONC CPT RB OWN PNT OWN PNT GW8 PNT GWB PNT ACP 9' -O" CFCI - PAINT VINYL COVERED WALLS OF DEMOUNTABLE PARM1ONS 134 OFFICE CONC CPT R8 GWB PNT GWB PNT .GWB PNT GWB PNT ACP 9' -O" CFCI - .PANT VINYL COVERED. WALLS OF DEMOUNTABLE PARTTIONS 135 OFFICE CONC CPT R8 OWN TNT OWN PNT GWB PNT GWB PNT ACP 9 CFCI - .PAINT VINYL COVERED WALLS OF DEMOUNTABLE PARm1ONS 136 HOUSING MGM7 C CONC CPT R8 OWN PNT OWN PNT GWB PNT GWB PNT ACP 9' -0 CFCI - PAINT VINYL COVERED: WALLS OF DEMOUNTABLE PARTITIONS SEE SHEET ID22 FOR PAINT COLOR LOCATION 137 COMMUNICATION CONC CPT R8 GWB PNT GWB PNT GWB PNT. GWB PNT. ACP 9` -0 ° SEE SHEET 02.2 FOR CARPET DESIGN -- SEE SHEET 102.2 FOR PAINT COLOR LOCATION 138 TELEPHGNE 139 HALL CONC CPT WOOD EXST /GWB PNT GWB PNT EXST /GW8 PNT - -- - -- ACP 9' -0 SEE SHEET 02.3 FOR CARPET DESIGN SEE SHEET 102.2 FOR PAINT COLOR LOCATION 140 MEN CONC EXST/111.E EXST/11LE EXST /TILE - -- EXST /TILE - -- EXST/TILE - -- EXST /TILE PNT EXST /GW8 9' -0` 141 MECH. ROOM - -- - -- - -- - -- - - -- - -- 142 WOMEN CONC EXST/TILE EXST/TILE EXST /TILE - -- EXST/TILE - -- EXST/TILE - -- EXST /TILE PNT EXST /GW8 9' -0 143 STAIR ONC/ i CPT WOOD EXST /GWB PNT •JcST /GWB PNT EXST /GWB PNT EXST /GWB PNT EXST /GW8 - -- SEE SHEET 02 -3 FOR CARPET DESIGN SEE SHEET 102.2 FOR PAINT COLOR LOCATION 144 ELEC. ROOM - -- - -- - -- - -- -- - -- --- 200 LOBBY •NC /• CPT RB GWB PNT GWB PNT GWB PNT GWB PNT ACP /GWB 9' -0" 201 RENTAL ONC • • -- R8 - -- -- OWB PNT --- - -- - -- - - -: --- --- 202 HALL : ONC/ • CPT RB OWN PNT OAR TNT GWB PNT OWB : PNT 9' -0 203 HALL : ONC /P • CPT R8 GWB PNT. GWB PNT GWB. PNT OWN PNT ACP 9,-0 SEE SHEEF 102.2 FOR CARPET DESIGN 204 OFFICE ONC / • • CPT RB MB PNT GWB PNT GWB PNT GWB PNT ACP 9' -0" SEE SHEET 102.2 FOR CARPET DESIGN SEE SHEET 'ID2.2 FOR PAINT COLOR LOCATION 205 OFFICE ONC • CPT R8 OWN PNT OWN PNT GWB PNT GW8 PNT ACP '9'. -0 SEE SHEET 102.2 FOR CARPET DESIGN SEE SHEET 102.2 FOR PAINT COLOR LOCATION 206 DIRECTOR ONC/ • CPT R8 GWB PNT OWB PNT GWB PNT GW8 PNT ACP 9' -0 ". 207 OPEN OFFICE ONC / • • CPT RB GWB PNT GWB PNT GWB PNT GWB PNT ACP 9' -0 SEE SHEET 102.2 FOR CARPET DESIGN SEE SHEET 022 FOR PAINT COLOR. LOCATION 208 INFO- SERVICES ONC / • • CPT RB GWB PNT OWB PNT GW8 PNT GWB PNT ACP 9' -0 SEE SHEET 102.2 FOR PAINT COLOR LOCATION 209 HALL ONC/ • CPT R8 GWB PNT OWN TNT GWB PNT GWB PNT ACP 9' -0" SEE SHEET 102.2 FOR PAINT COLOR LOCATION 210 WORK AREA ONC / • • CPT R8 GWB PNT OWB TNT GW8 PNT GWB PNT ACP 9' -0 211 MAINT. & CLNST. ONC /P • CPT R8 GWB PNT GWB PNT GWB PNT : : GWB. PNT ACP 9' -0" SEE SHEET 102.2 FOR CARPET DESIGN SEE SHEET 02.2 FOR PAINT COLOR LOCATION 212 DIRECTOR ONC/ • • CPT RB GWB PNT GWB TNT OW8 PNT GWB PNT ACP 9' -0" 213 OFFICE ONC /P • CPT RB GW8 PNT GWB PNT GWB PNT : OWN PNT ACP 9' -0" 214 STAIR ONC /P CPT RB GWB PNT GWB PNT GWB PNT GWB PNT ACP 9' -0 SEE SHEET ID2.2 FOR PAINT COLOR LOCATION 215 HALL ONC / • • CPT R8 GWB PNT GWB PNT GW8 PNT GWB PNT ACP 9' -0 SEE SHEET 002.2 FOR CARPET DESIGN 216 DEVELOPMENT ONC / • • CPT RB GWB PNT GWB PNT GW8 PNT GWB PNT ACP 9' -0 SEE SHEET 02 -2 FOR CARPET DESIGN SEE SHEET 1D2.2 FOR PAINT COLOR LOCATION 217 DIRECTOR ONC / • • CPT RB GWB PNT GWB PNT OWN PNT GW8 PNT ACP 9' -0" 218 OFFICE ONC /PW CPT RB GWB PNT GW8 PNT GWB PNT GWB PNT ACP 9' -0" CFCI - PANT VINYL COVERED WALLS OF DEMOUNTABLE PARTITIONS 219 ASSET MGM7 ONC /PW CPT RB GWB PNT ..GWB PNT. GWB. PNT. OWN PNT ACP 9' -0" SEE SIT 102.2 FOR CARPET DESIGN & PAINT COLOR LOCATION / CFCI - PAINT VINYL COVERED WALLS OF DEMOUNTABLE PARTITIONS 220 WORK AREA ONC /PW• CPT R8 GWB PNT GWB PNT GWB PNT GWB PNT ACP 9' -0 SEE SHEET 102.2 FOR CARPET DESIGN SEE SHEET 102.2 FOR PAINT COLOR LOCATION 221 DIRECTOR ONC /PWD CPT RB OWN PNT GWB PNT GWB PNT GWB PNT ACP 9' -0" 222 CONFERENCE 0NC /PW CPT R8 GWB PNT GWB PNT GWB PNT GW8 PNT ACP 9' -0" 223 LOUNGE ONC/PW CPT /SV RB GWB PNT GWB PNT GWB PNT GW8 PNT ACP- 9' -0" SEE SHEET ID2 -2 FOR CARPET AND SHEET VINYL DESIGN 224 WAITING ONC/ • • SV RB GWB PNT OWB PNT GWB PNT GWB PNT ACP 9': -0 226 HALL ONC /PWO CPT WOOD EXST /Gw8 PNT GWB PNT `_XST /GW8 PNT - -- -. -- ACP 9' -0 227 MEN /PWD EXST/TILE EXST/TRE EXST/TILE - -- EXST/TILE - -- EXST/TILE - EXST /TILE PNT . EXST /GWB 9' 0 :.. 228 MECH. ROOM ___ ___, ___ ___ ___ _ __ ___ ___ __ -_- -__ _.. _- 229 WOMEN 0 NC /PWO EXST/TILE EXST /TILE F ST /TILE - -- EXST /TILE - -- EXST /TILE - EXST /TILE PNT EXST /GW8 9', -0 230. STAIR ONC /PWD CPT WOOD GWB PNT GWB PNT ' GWB GWN .PNT EXST /GWB - -- SEE' 102.2 FOR PAINT COLOR LOCATION 231 ELEC. ROOM - -- - -- - -- --- - -- - -- - -- - -- - -- - -- - -- - - -.. - -- 232 TELEPHONE -- - -- - -- ' - -- APPRO\I D A48 2 8 290(1 gvl'._DtivG DI S1ON SYr\ THESISLLC THE FUSION OF ARCHITECTURE, DESIGN TECHNOLOGY & PEOPLE ISSUE NO. DESIGNED BY. JS DATE. 2Ti- 130th Avenue NE, Sine 202 Bellevue, WA98005 425 8691946 (6E0425 885 6208 Sssks Pop A S S O C i A T E S Interior Planning & Design PHONE 206 236 -7273 FAX 206 236 -1240 rjseeks@aal_com CELL 206 605 -1501 4259 EAST MERCER WAY MERCER ISLAND, WA 98040 REVISIONS D2000 -091 DATE PROFESSIONAL STAMP 03/23/2000 PROJECT No- 98009 - 03.000 _ � n c(:IJiL rI L� _ . - PROJECT INFORMATION KING HOUSING AUTHORITY TENANT IMPROVEMENTS CENTRAL OFFICE 600 Andover Park West Tukwila, WA 98118 SHEET INFORMATION RELEASE FOn• ISSUED FOR PERMIT ROOM FINISH SCHEDULEg9m GRYOFTUKWL4 MAR 2 ; a.. REVIEWED WO APPROVED BY• SHEET NO. • *W Y• ST ' RMlTCENTEi, A3.2 www.synthesisllc.com 1 /2 "X WD TRIM GWB J / WALL csk LOBBY 200 5 -0" 0" -O" I I LOBBY 100 WEST w 45• END PANEL FILLER SURFACING SYSTEM c LOBBY ELEVATIONS 100 & 200 SCALE: 1 \4 " =1' -0" r = - - 1111 - - - - - -■ MEM 'Ir PLAN PLAM END PANEL RI3 SOUTH NORTH CURVE WALL MI CURVE KNEE SPACE 3 -0" 3' - ' W/ SUPPORT AS REQ (2 184) 2 -0 END PANEL HUMAN RESOURCES COUNTER 102 2 SCALE: 1 \4 " =1' -0" WEST GWB 8 OAK BASE TYP GWB CHAIR RAIL 8" OAK BASE GYP END PANEL BACKSPLASH PLAM 22�� 3 PWD RB CURVE KNEE SPACE W/ SUPPORT AS REQ (2 MIN) END PANEL 5 -0 KNEE SPACE W/ END PANEL SUPPORT AS REO (1 MIN) EAST GWB LOBBY 200 DF 5 -0 HALL 226 i N OF01 FILES SCALE: 1 \4 " =1' -0" c I I � L i I � I t 6 PLAN O TYPICAL DEPARTMENT ENTRY 3 SCALE: 1 \4' =1' -0 OF01 FILES SEE DTLS 5,8/A9.1 FIN FL PLAM EDGES EQ I, EQ ' FRONT West SIDE RESIDENTIAL SERVICES COUNTER 1/2 "X WD GWB WALL SURFACING SYSTEM FIN CLG 5• -0" d REMOVE SIDE WD TRIM REPLACE W/ SHORT BACKSPASH NORTH n LOUNGE 223 J. SCALE: 1 \4 "= 1' -0' v SCALE 1 \4 " =1' -0 ® OFFICE 121 DESK SCALE: 1 \4 " =1' -0" PLAM RB NORTH \ J i11\ L,AIL\J \ GWB 2' -O" 2' -O" 2 , -0 ° 10' -6" VERIFY WALL SURFACING SYSTEM �GWBJ 1 /2 "X WD TRIM STAIR 230 8" OAK BASE TYP GWB CHAIR RAIL MODESTY /SUPPORT PANEL PLAM BREAK ROOM 124 SEE DRS 5,6,7,8/A9.1 8' 0A1< BASE TYP RANGE HOOD OFCI 2 -6" 3' -0" 2.5 APRON TO CONCEAL EAST ' " UNDER COUNTER LIGHT EAST pLAM i OVER (2)_ 3/4° Pw0 KNEE SPACES 6" COL �-- RB ALL AROUND SOUTH EDGES 1' - 9" SOUTH GWB WALL SURFACING SYSTEM 2. -0 " 4' - 4 4. - 0' "i' OFOI FILES BEAM AS REQ 11' -0 BEAM AS REQ LAM OVER (2) 3/4 PWD RB RB O PANEL EXIST. FILE FOI NORTH PLAM EDGES EAST MAINTENANCE & CONST COUNTER 8 SCALE: 1 \4 " =1' -0" .5" APRON EXTENDS AROUND CORNER RETURN TO WALL PLAN CHAIR RAIL EXTEND. AROUND CORNER THEN MITER & RETURN TO FLOOR A ?Tz' I ` i4 � pp0 2 5 'L11U1A gt)1LDiNG ONISION SYNTHESISfC THE FUSION OF ARCHITECTURE, D -SIGN TECHNOLOGY & PEOPLE • 2353'130(6 Avenue NE, Sage 202 Bellevue, WA98005 425 8691946 (1ax) 425 885 6208 ISSUE NO. Sssktgn A S S O ES F A T E S REVISIONS DZ000 -091 DESIGNED BY• JS Interior Planning & Design PHONE 206 236 -7273 FAX 206 236 -1240 rjseeks @aoI_com CELL 206 605 -1501 4259 EAST MERCER WAY MERCER ISLAND, WA 98040 DATE INTERIOR ELEVATIONS DADS 03/23/2000 SHEET NO. PSGAECT No. 98009.03.000 ITEM PROFESSIONAL STAMP PROJECT INFORMATION KING CO: HOUSING AUTHORITY TENANT IMPROVEMENTS CENTRAL OFFICE 600 Andover Park West Tukwila, WA 98118 SHEET INFORMATION RELEASE FON ISSUED FOR PERMIT. CITY OF TUKWILA ITS S S. STAFF RENEWED BY. APPROVED BY• MAR 2 4 ::tali Pawn CENTER A5.1 www.synthesisllc.com o LOBBY 100 "l HALL / / \ \ / / / - // 1 /2 "X WD TRIM GWB J / WALL csk LOBBY 200 5 -0" 0" -O" I I LOBBY 100 WEST w 45• END PANEL FILLER SURFACING SYSTEM c LOBBY ELEVATIONS 100 & 200 SCALE: 1 \4 " =1' -0" r = - - 1111 - - - - - -■ MEM 'Ir PLAN PLAM END PANEL RI3 SOUTH NORTH CURVE WALL MI CURVE KNEE SPACE 3 -0" 3' - ' W/ SUPPORT AS REQ (2 184) 2 -0 END PANEL HUMAN RESOURCES COUNTER 102 2 SCALE: 1 \4 " =1' -0" WEST GWB 8 OAK BASE TYP GWB CHAIR RAIL 8" OAK BASE GYP END PANEL BACKSPLASH PLAM 22�� 3 PWD RB CURVE KNEE SPACE W/ SUPPORT AS REQ (2 MIN) END PANEL 5 -0 KNEE SPACE W/ END PANEL SUPPORT AS REO (1 MIN) EAST GWB LOBBY 200 DF 5 -0 HALL 226 i N OF01 FILES SCALE: 1 \4 " =1' -0" c I I � L i I � I t 6 PLAN O TYPICAL DEPARTMENT ENTRY 3 SCALE: 1 \4' =1' -0 OF01 FILES SEE DTLS 5,8/A9.1 FIN FL PLAM EDGES EQ I, EQ ' FRONT West SIDE RESIDENTIAL SERVICES COUNTER 1/2 "X WD GWB WALL SURFACING SYSTEM FIN CLG 5• -0" d REMOVE SIDE WD TRIM REPLACE W/ SHORT BACKSPASH NORTH n LOUNGE 223 J. SCALE: 1 \4 "= 1' -0' v SCALE 1 \4 " =1' -0 ® OFFICE 121 DESK SCALE: 1 \4 " =1' -0" PLAM RB NORTH \ J i11\ L,AIL\J \ GWB 2' -O" 2' -O" 2 , -0 ° 10' -6" VERIFY WALL SURFACING SYSTEM �GWBJ 1 /2 "X WD TRIM STAIR 230 8" OAK BASE TYP GWB CHAIR RAIL MODESTY /SUPPORT PANEL PLAM BREAK ROOM 124 SEE DRS 5,6,7,8/A9.1 8' 0A1< BASE TYP RANGE HOOD OFCI 2 -6" 3' -0" 2.5 APRON TO CONCEAL EAST ' " UNDER COUNTER LIGHT EAST pLAM i OVER (2)_ 3/4° Pw0 KNEE SPACES 6" COL �-- RB ALL AROUND SOUTH EDGES 1' - 9" SOUTH GWB WALL SURFACING SYSTEM 2. -0 " 4' - 4 4. - 0' "i' OFOI FILES BEAM AS REQ 11' -0 BEAM AS REQ LAM OVER (2) 3/4 PWD RB RB O PANEL EXIST. FILE FOI NORTH PLAM EDGES EAST MAINTENANCE & CONST COUNTER 8 SCALE: 1 \4 " =1' -0" .5" APRON EXTENDS AROUND CORNER RETURN TO WALL PLAN CHAIR RAIL EXTEND. AROUND CORNER THEN MITER & RETURN TO FLOOR A ?Tz' I ` i4 � pp0 2 5 'L11U1A gt)1LDiNG ONISION SYNTHESISfC THE FUSION OF ARCHITECTURE, D -SIGN TECHNOLOGY & PEOPLE • 2353'130(6 Avenue NE, Sage 202 Bellevue, WA98005 425 8691946 (1ax) 425 885 6208 ISSUE NO. Sssktgn A S S O ES F A T E S REVISIONS DZ000 -091 DESIGNED BY• JS Interior Planning & Design PHONE 206 236 -7273 FAX 206 236 -1240 rjseeks @aoI_com CELL 206 605 -1501 4259 EAST MERCER WAY MERCER ISLAND, WA 98040 DATE INTERIOR ELEVATIONS DADS 03/23/2000 SHEET NO. PSGAECT No. 98009.03.000 ITEM PROFESSIONAL STAMP PROJECT INFORMATION KING CO: HOUSING AUTHORITY TENANT IMPROVEMENTS CENTRAL OFFICE 600 Andover Park West Tukwila, WA 98118 SHEET INFORMATION RELEASE FON ISSUED FOR PERMIT. CITY OF TUKWILA ITS S S. STAFF RENEWED BY. APPROVED BY• MAR 2 4 ::tali Pawn CENTER A5.1 www.synthesisllc.com KNEE SPACES BACKSPLASH SCALE 3/4 " =1 -0" SOUTH O MAINTENANCE & CONST 211 SCALE: 1 \4' =1' -0" O COUNTER TOP PLAN SEE DETAIL 17/A9.1 5 Ira SOUTH TOILET 125 2 SCALE: 1 \4 =1' -0" FIBERGLASS SHOVER BL SERF, NI®.OUR ACCESSIBLE GWB FRERGIASS SHOVER INSERT, WHEELCHAIR ACCESSIBLE PAPER TOWEL 06PENSER/ WASTE RECEPTACLE /R) IAV, IYP R NATO) COVER PER WAC 1106.11.7.4 RIEGRAL SV COVE BASE DP WEST N O REFLECTED CEILING PLAN 6 SCALE: 3/4 ° =1' -0" 3 ' SOUTH CONFERENCE 109 SEE DRS 6,8/A9.1 O SCALE: 1 \4 " =1' -0 " EAST C WORK AREA 210 I SCALE: 1 \4 " =1' -0" 2.5 " APRON TO CONCEAL UNDERCOUNTER LT BACKSPLASH PLAM R8 GWB K & PO V ADJUSTABLE SHELF W/ p (5) SHELVES AS REO PLAM OVER (2) 3/4" PWD TYP PLAM EDGES & PANELS TYP KNEE SPACE W/ SUPPORT (2 MIN) KNEE SPACE W/ SUPPORT (3 MIN) RB SOUTH WEST (2) ADJ.. SHELVES IN BOX UNITS 2.5 APRON TO CONCEAL UNDERCOUNTER LT (2. SIDES SAME) BACKSPLASH PLAM EDGES & PANELS HOUSING MANAGEMENT B 132 7 SCALE: 0" SYNTHESIS LLC THE FUSION OF ARCHITECTURE. DESIGN TECHNOLOGY & PEOP_E ISSUE NO. Tins DESIGNED BY. JS RENEWED BY. DATE. 2353 130th AVetaee NE, Stoma 202 Bellevue, WA 98005 425 8691946 (fax) 425 885 6208 Sssk t)siijn A S u O 0 A T E S interior Planning & Design PHONE 206 236 -7273 FAX 206 236 -1240 rjseeks@aol_eom CELL 206 605 -1501 4259 EAST MERCER WAY MERCER ISLAND, WA 98040 REVISIONS D2000 -091 DATE PROFESSIONAL STAMP PROJECT INFORMATION KING CO. HOUSING AUTHORITY TENANT IMPROVEMENTS CENTRAL OFFICE 600 Andover Park West Tukwila, WA 98118 SHEET INFORMATION RECEIVED QTEY RELEASE FOB ISSUED FOR PERMIT INTERIOR MAR 2 4 70, ELEVATIONS AND DETAILSERMITCENTER 03/23/2000 SHEET NO. PROJECT No- 98009.03.000 DRAWN By. STAFF APPROVED BY. A5.2 www.s nthesisllc.com C NORTH NORTH SECOND FLOOR REFLECTED CEILING PLAN SCALE: 1/8 " =1' -0" FIRST FLOOR REFLECTED CEILING PLAN SCALE: 1/8'" =1 -0" n tc) {s� REFLECTED CEILING PLAN KEYNOTES NOTE: FIXTURES SHOWN ARE FOR LOCATION AND GENERAL TYPE - SE. ELECTRICAL FOR EXACT LIGHT FIXTURE'. TYPES PROVIDE ILLUMINATED EXIT SIGNS AS REQUIRED BY CODE - SEE ELECTRICAL FOR FIXTURES AND LOCATIONS WALLS EXTEND TO BOTT OF GRID UNLESS OTHERWISE NOTED - SEE WALL TYPES AND DTL 16/A9.1 I EXIST EXISTING SUSPENDED ACOUSTICAL CEILING ® 9' -0" AFF CEILING TILE TO BE REMOVED AND REINSTALLED BY OWNER EXISTING GRID TO REMAIN - REPAJNT ENTIRE GRID REPAIR, PATCH AND REPLACE DAMAGED SECTIONS AS REQUIRED FOR 'LIKE NEW APPEARANCE REBRACE AS REQUIRED FOR SEISMIC - SEE DTL 9/A9.1 - INCLUDES ALL ROOMS WITH THE EXCEPTION OF RM 201 NEW GWB CEILING ® 8' -0 AFF- SEE DETAIL 2/A9.1 PROVIDE EXHAUST FAN - SEE ELECTRICAL REPAINT CEILINGS PROVIDE NEW UGHTING FIXTURES REPAINT CEILINGS THIS AREA N.I.C. 77 PROVIDE SOUND BATT INSULATION ONTOP OF CEILING TILE - ONTOP AND 4' EACH SIDE OF PARTITION WALL BELOW LEGEND EXISTING LOCATION OF 2x4 FLUORESCENT PROVIDE 2x4 FLUORESCENT RECESSED 2x4 FLUORESCENT - RECESSED 2x2 FLUORESCENT- RECESSED PENDENT MOUNT LIGHTING FIXTURE UNDERCOUNTER FLUORESCENT DIRECTIONAL CAN FIXTURE - RECESSED EXISTING LOCATION OF INCANDESCENT CAN FIXTURE EXIST PROVIDE FLUORESCENT CAN FIXTURE RECESSED Q FLUORESCENT CAN FIXTURE -. RECESSED D LIGHT FIXTURE - WALL MOUNTED D EXISTING LOCATION OF WALL 'MOUNTED FIXTURE EXIST PROVIDE NEW WALL MOUNTED FIXTURE W SPRINKLER HEAD VERIFY AS -BUILT LO 1 `I EXISTING LOCATIONS SHOWN ONLY FOR FINAL LOCATIONS - BIDDER DESIGN - a ISSUE NO. DATE 4 SYNTHESISLLC THE FUSION OF ARCHITECTURE. DESIGN TECHNOLOGY & PEOPLE 2353 130th Avenue NE, Suie 202 Bellevue, INA 98005 425 869 1946 (fax) 425 885 6208 DESIGNED Sy. JS FIE-VIEWED 13, Sssk Ison A .S O C 1 ATE. DATE. 03/23/2000 PROJECT )X 98009.03.000 Interior Planning & Design PHONE 206 236 -7273 FAX 206236-1240 r }seeks @aot.com CELL 206 605 -1501 4259 EAST MERCER WAY MERCER ISLAND, WA98040 REVISIONS D2000 -0 PROFESSIONAL STAMP PROJECT INFORMATION KING CO: HOUSING AUTHORITY TENANT IMPROVEMENTS CENTRAL OFFICE 600 Andover Park West Tukwila, WA 98118 SHEET INFORMATION RELEASE Fan ISSUED FOR PERMIT 'rm.. REFLECTED CEILING PLANS SHEET. ITEM RECEIVED p � CITT wuxm a, sN 2 # 205 APPROVED Sr. PERMIT CENTER A6.1 www.synthesislIc.com I I - =min= .ii�ii ii.( ■ ®_Sums ®1.— X71.∎ ilt ii — 1 pm • ammonium bir L � iii NommEmfil•tiiii.l� rimmmag m i�i>•im �i�i�ii.(iiil i .IE=60iim iMII=O1:ii0. $���ii.EWMIMI �,_'.�► vOi .. �I■I.I•i�NiiM��>N.liii. �l IMKII=ii11ii®m iii0i. ii.iiiiiilll MI ■i∎ IMMO i�\i ■M _e-s, EzIST E}- I 3 — != viii i_iiiiiii� �i iiiE= .iiii_INi - ■ ■■UH�C ® 1 ®' in • \ • 1♦'� =- = . ION =® a ®i ® ��� ®:— 6 !�i"t!�'e�f._�==— ® ` �® T ®� II ll - - �i(IST ms — i®®iiiiiiiii ii!� iiii iiiaiiII I I MIMMI • r_I IM • c i Wli \'i �i 1 iw� • - giro] • III • • ' t ∎ "'`��iIl = MI ®ML`iiw Ii/;11iI ° ®IliiiliiP.iii.� iMIUM •I1171 l MIWAIis INIMME i�iii®i.7�,�I iii ° t, ,; • • ©I Jiii®[° ii.l.�i NE= .I.�i � \ ® ®_.\ \ I _ i.®i��It.-- I!U iii i> . 1 I AXIS MIMMI1.!!alaiOi..L•lMI O ' ■ .. ■ i0i9 ■■ \'i ce' — >• w ®iii�li \ ®I1� � �III I 1 - , � — IL I • • ° i I _I ■■ =maim ... =MI N i ii l0i1.d _ EXnT • iia■ rtilL. ' ` �. • . _�ii.li \ 1 MI aim I! �=moan i Ci�l • � III • -' moms ili__�ii 1 M� . . • EuIST = iiiiiii/'�= i.=ii"7iiiiii i►/ ° • 311 ■■••■RIMMINW_ IM .. I.I $XIS I I� I is 1. .I� 'ice l. ° • m �iLmit iiFl►iiaU M .■ �'iim H -_�--�i11 OMMIS � A0.0.0I ,.- O MM...il ' -• . M � /� _....m..., : �n. i _ . = iiiiii�iiiiiii ■ �— I III t . t i i t ire ■ C - • y • 6 {. j ,_ EXIST 3 _ . . I �� -- I ' © ii-iiiiiiii y .��� I I _ _ _ _ I ��� ∎ .� I , �j I . ..►,I �0 .Ilio�iili.l....m.w MIM ISMIiEIMMII I�O ' �I�i�iiOi_iii= alii .. O iii =i ` u NMI I !.. :.I • • • • { L ® `�.. _ I •. r.... i viii i� ®� NE l �i =iii d ®ice �`�` �i�istOl��i Iii ii ■Mi�!il�M�ii��i -- iii mIiiiii —i'PMEN_ .'' ' G �� ( ST _ X sal A. a m I= I I Mil ! ∎ 1 ■■E ® ® • I` l ® =EWE � i I•i>• ai . — . . •�•6• I.. MUM= m i..oi ■i () —_— MEMMIM►I �N S ii ®i ®IEi� i�i�® 1l.iiii� C NORTH NORTH SECOND FLOOR REFLECTED CEILING PLAN SCALE: 1/8 " =1' -0" FIRST FLOOR REFLECTED CEILING PLAN SCALE: 1/8'" =1 -0" n tc) {s� REFLECTED CEILING PLAN KEYNOTES NOTE: FIXTURES SHOWN ARE FOR LOCATION AND GENERAL TYPE - SE. ELECTRICAL FOR EXACT LIGHT FIXTURE'. TYPES PROVIDE ILLUMINATED EXIT SIGNS AS REQUIRED BY CODE - SEE ELECTRICAL FOR FIXTURES AND LOCATIONS WALLS EXTEND TO BOTT OF GRID UNLESS OTHERWISE NOTED - SEE WALL TYPES AND DTL 16/A9.1 I EXIST EXISTING SUSPENDED ACOUSTICAL CEILING ® 9' -0" AFF CEILING TILE TO BE REMOVED AND REINSTALLED BY OWNER EXISTING GRID TO REMAIN - REPAJNT ENTIRE GRID REPAIR, PATCH AND REPLACE DAMAGED SECTIONS AS REQUIRED FOR 'LIKE NEW APPEARANCE REBRACE AS REQUIRED FOR SEISMIC - SEE DTL 9/A9.1 - INCLUDES ALL ROOMS WITH THE EXCEPTION OF RM 201 NEW GWB CEILING ® 8' -0 AFF- SEE DETAIL 2/A9.1 PROVIDE EXHAUST FAN - SEE ELECTRICAL REPAINT CEILINGS PROVIDE NEW UGHTING FIXTURES REPAINT CEILINGS THIS AREA N.I.C. 77 PROVIDE SOUND BATT INSULATION ONTOP OF CEILING TILE - ONTOP AND 4' EACH SIDE OF PARTITION WALL BELOW LEGEND EXISTING LOCATION OF 2x4 FLUORESCENT PROVIDE 2x4 FLUORESCENT RECESSED 2x4 FLUORESCENT - RECESSED 2x2 FLUORESCENT- RECESSED PENDENT MOUNT LIGHTING FIXTURE UNDERCOUNTER FLUORESCENT DIRECTIONAL CAN FIXTURE - RECESSED EXISTING LOCATION OF INCANDESCENT CAN FIXTURE EXIST PROVIDE FLUORESCENT CAN FIXTURE RECESSED Q FLUORESCENT CAN FIXTURE -. RECESSED D LIGHT FIXTURE - WALL MOUNTED D EXISTING LOCATION OF WALL 'MOUNTED FIXTURE EXIST PROVIDE NEW WALL MOUNTED FIXTURE W SPRINKLER HEAD VERIFY AS -BUILT LO 1 `I EXISTING LOCATIONS SHOWN ONLY FOR FINAL LOCATIONS - BIDDER DESIGN - a ISSUE NO. DATE 4 SYNTHESISLLC THE FUSION OF ARCHITECTURE. DESIGN TECHNOLOGY & PEOPLE 2353 130th Avenue NE, Suie 202 Bellevue, INA 98005 425 869 1946 (fax) 425 885 6208 DESIGNED Sy. JS FIE-VIEWED 13, Sssk Ison A .S O C 1 ATE. DATE. 03/23/2000 PROJECT )X 98009.03.000 Interior Planning & Design PHONE 206 236 -7273 FAX 206236-1240 r }seeks @aot.com CELL 206 605 -1501 4259 EAST MERCER WAY MERCER ISLAND, WA98040 REVISIONS D2000 -0 PROFESSIONAL STAMP PROJECT INFORMATION KING CO: HOUSING AUTHORITY TENANT IMPROVEMENTS CENTRAL OFFICE 600 Andover Park West Tukwila, WA 98118 SHEET INFORMATION RELEASE Fan ISSUED FOR PERMIT 'rm.. REFLECTED CEILING PLANS SHEET. ITEM RECEIVED p � CITT wuxm a, sN 2 # 205 APPROVED Sr. PERMIT CENTER A6.1 www.synthesislIc.com I I =min= .. iiiii i ii® ilt ii • ammonium bir L � iii _ ®iii rimmmag � ®>•i ∎it i ®eiiaii�� iiiii� i, i I .IE=60iim iMII=O1:ii0. $���ii.EWMIMI �,_'.�► vOi .. �I■I.I•i�NiiM��>N.liii. �l IMKII=ii11ii®m iii0i. ii.iiiiiilll MI ■i∎ i�\i ■M MIMI — != viii i_iiiiiii� �i iiiE= .iiii_INi iii • \ ==1. 1♦'� 6 m_ = ` T ®imiszummoifl ms — i®®iiiiiiiii ii!� iiii iiiaiiII I I MIMMI • r_I IM • Se® i Wli \'i �i 1 • - ii.i©iiviMI iilMUli=1 iiiLMiilii0' I i�r • •. . ∎ "'`��iIl ____ �iiliiiiiiIiii 111111MiaIr MI ®ML`iiw Ii/;11iI ° ®IliiiliiP.iii.� iMIUM •I1171 l MIWAIis INIMME i�iii®i.7�,�I iii ° t, ,; • • ©I Jiii®[° IBM= I CIL=MI � �ir►1ii! ® I M SiiviiiH ® - ° I _ i.®i��It.-- I!U iii i> . 1 I • �1 MIMMI1.!!alaiOi..L•lMI O Mill ll ■ii MI . ..... —..... ■ .. ■ i0i9 ■■ =MIME E►�iiiiFIRS iu �� w ®iii�li ■ CO.. , � — IL I • • ° ... =MI N i ii l0i1.d • T IM Ire • I rtilL. AN iiiiiii/'�= i.=ii"7iiiiii i►/ ° • iii ii.`tt■■ I I� I is 1. .I� 'ice l. �iLmit iiFl►iiaU M .■ �'iim H -_�--�i11 ., ' ° A0.0.0I ,.- O MM...il ' -• . M e1■17HiMMI mi. =MOM= _ . = iiiiii�iiiiiii ■ �— I .11e...pjr���' �\ !iai ii i t ire 6 {. j ,_ EXIST 3 _ . . I �� -- I ' © ii-iiiiiiii ■ jj i 11 I I _ _ _ _ I ��� ∎ .� I , �j I . C NORTH NORTH SECOND FLOOR REFLECTED CEILING PLAN SCALE: 1/8 " =1' -0" FIRST FLOOR REFLECTED CEILING PLAN SCALE: 1/8'" =1 -0" n tc) {s� REFLECTED CEILING PLAN KEYNOTES NOTE: FIXTURES SHOWN ARE FOR LOCATION AND GENERAL TYPE - SE. ELECTRICAL FOR EXACT LIGHT FIXTURE'. TYPES PROVIDE ILLUMINATED EXIT SIGNS AS REQUIRED BY CODE - SEE ELECTRICAL FOR FIXTURES AND LOCATIONS WALLS EXTEND TO BOTT OF GRID UNLESS OTHERWISE NOTED - SEE WALL TYPES AND DTL 16/A9.1 I EXIST EXISTING SUSPENDED ACOUSTICAL CEILING ® 9' -0" AFF CEILING TILE TO BE REMOVED AND REINSTALLED BY OWNER EXISTING GRID TO REMAIN - REPAJNT ENTIRE GRID REPAIR, PATCH AND REPLACE DAMAGED SECTIONS AS REQUIRED FOR 'LIKE NEW APPEARANCE REBRACE AS REQUIRED FOR SEISMIC - SEE DTL 9/A9.1 - INCLUDES ALL ROOMS WITH THE EXCEPTION OF RM 201 NEW GWB CEILING ® 8' -0 AFF- SEE DETAIL 2/A9.1 PROVIDE EXHAUST FAN - SEE ELECTRICAL REPAINT CEILINGS PROVIDE NEW UGHTING FIXTURES REPAINT CEILINGS THIS AREA N.I.C. 77 PROVIDE SOUND BATT INSULATION ONTOP OF CEILING TILE - ONTOP AND 4' EACH SIDE OF PARTITION WALL BELOW LEGEND EXISTING LOCATION OF 2x4 FLUORESCENT PROVIDE 2x4 FLUORESCENT RECESSED 2x4 FLUORESCENT - RECESSED 2x2 FLUORESCENT- RECESSED PENDENT MOUNT LIGHTING FIXTURE UNDERCOUNTER FLUORESCENT DIRECTIONAL CAN FIXTURE - RECESSED EXISTING LOCATION OF INCANDESCENT CAN FIXTURE EXIST PROVIDE FLUORESCENT CAN FIXTURE RECESSED Q FLUORESCENT CAN FIXTURE -. RECESSED D LIGHT FIXTURE - WALL MOUNTED D EXISTING LOCATION OF WALL 'MOUNTED FIXTURE EXIST PROVIDE NEW WALL MOUNTED FIXTURE W SPRINKLER HEAD VERIFY AS -BUILT LO 1 `I EXISTING LOCATIONS SHOWN ONLY FOR FINAL LOCATIONS - BIDDER DESIGN - a ISSUE NO. DATE 4 SYNTHESISLLC THE FUSION OF ARCHITECTURE. DESIGN TECHNOLOGY & PEOPLE 2353 130th Avenue NE, Suie 202 Bellevue, INA 98005 425 869 1946 (fax) 425 885 6208 DESIGNED Sy. JS FIE-VIEWED 13, Sssk Ison A .S O C 1 ATE. DATE. 03/23/2000 PROJECT )X 98009.03.000 Interior Planning & Design PHONE 206 236 -7273 FAX 206236-1240 r }seeks @aot.com CELL 206 605 -1501 4259 EAST MERCER WAY MERCER ISLAND, WA98040 REVISIONS D2000 -0 PROFESSIONAL STAMP PROJECT INFORMATION KING CO: HOUSING AUTHORITY TENANT IMPROVEMENTS CENTRAL OFFICE 600 Andover Park West Tukwila, WA 98118 SHEET INFORMATION RELEASE Fan ISSUED FOR PERMIT 'rm.. REFLECTED CEILING PLANS SHEET. ITEM RECEIVED p � CITT wuxm a, sN 2 # 205 APPROVED Sr. PERMIT CENTER A6.1 www.synthesislIc.com ® SUSP.CEILINC SEISMIC BRACE SCALE: N.T.S. O PARTITION TO FLOOR 'CONNECTION SCALE: 3 " =1' -0" 3 TURNS MIN. TYP UPPER CABINET SCALE: 3/4 " =1' -0" MAN RUNNER CROSS RUNNER COMPRESSION POST @ 12' -0' 0.C. EA. WAY 12 GA. SPLAY WIRE IN PLANE OF EA. RUNNER (4 REQ'D.- 45' ANGLE MAX.) WALL TRIM SCALE:6 " =1 ' -0" / 8" MAX -- I 1 1 1 1 , 1 , I I I I SCALE: 3 " =1 -0 ,8" MAX , TYPICAL PARTITION WALL PER FLOOR PLAN VINYL COVE BASE MITER CUT NXDE CORNERS, WRAP OUTSIDE CORNERS (TIP) CARPET PER FINISH SCHEDULE 12 GA. VERT. WIRE HANGER @ 4' -0' O.C. ADJ. HANGER SIZE FOR LOADING PER CODE. 1/2" x 2" CLEAR FIR - FINISH FLUSH TO MATCH 1/2 CEMENT BD. SIDE TRIM SEE DETAIL 13/A9.1 5/8" GWB WALL CHAIR RAIL SEE DETAIL 10/A9_1 WALL SURFACING SYSTEM W/ PERIMETER & MAIN RUNNER EDGING- ATTACH PER MFG. RECOMMENDATIONS 3/4 x 8" OAK BASE - PREFINISH -CURF AS REQUIRED FINISH FLOOR #12 GA HANGER WIRE FASTEN MEMBERS TO WALL ANGLE 0 ONE WALL EA DIRECTION — " - I -- 1/2" SPACE ED OPP WALL FOR MOVEMENT ACP TYP CEILING SUPPORT @ WALL GWB CEILING GWB EA SIDE OF NIL OR WE STUDS -SEE WAIL TYPES O CEILING @ TOILET ROOM 2 SCALE: 1 1/2 " =1' -0" 5/8 0 10 CHAIR RAIL IT SCALE: FULL WALL SURFACING SYSTEM SCALE :6 " =1' -0" CEILING GASKET SCALE: 3 " =1' -0" NIL TOP RUNNER TRACK OR WD TOP PATE DOSING SUSPENDED CEILING GOB ONE SOW OF STUDS TO 6" ABOVE RN CBUNG FRAHM FOR GWB CEILING AT 16" OC SOLD BUM SOUND BAIT INSULATION MELAMINE SHELF ON KV SHELF SUPPORTS PLAM DOOR W/ CONCEALED HINGES - PLAM ALL EDGES, TYP CABINET INTERIOR OF LOW PRESSURE LAMINATE (WHITE MALAMINE) WIRE PULLS, TYP OAK CHAIR RAIL 5/8" GWB OVER 3 1/2 METAL STUDS 1/2" CEMENT BD TRIM 'J' MOULDING EDGES PROVIDE EXTRA WALL STUD FOR ATTACHEMENT WALL SURFACING SYSTEM W/ PERIMETER & CROSS RUNNER EDGING- ATTACH PER MFG. RECOMMENDATIONS HANGER WIRE EXPOSED SPURT 3 1/2" x 1/2 FINISH WOOD SPACER PANT TO MATCH FRAME ATTACH TO CDDNG GRID AS REQUIRED FOR FIRM LATERAL ATTACHMENT MOULDING TYPICAL AT TOP OF WALL 1 LAYER 5`8" TYPE 'X' GWB EA SIDE OF STUDS SEE WALL TYPES to w CABINET OVER REFR 7 SCALE: 3/4 " =1' -0" ACP CLG W/ MAIN RUNNER ACROSS OPENING 5/8" GWB OVER 3 1/2 MTL STUDS 0 16 OC - ALIGN FACE OF GWB W/ FACE OF CONC. 1/2" FIBER- CEMENT BD J MOLD CORNER MTL 5/8" GWB WALL @ AL WINDOW GLASS SCALE: 3 " =1' -0" O 14 TRACK SECTION SCALE: 1 1/2 " =1' -0" 4' -10" 5/8" GWB OVER 3 1/2" MTL STUDS TO FLR ABOVE O 7 TRACK DETAIL 1 SCALE: ' 1/2 " =1 -0" MTL FURRING CHANNEL @ 24" OC 1/2" FIBER CEMENT BD /8" GWB EA SIDE OF 3 1/2" NIL STASIS SEE WALL TYPES FRY j DMEC - 4875 DRY WALL MOLDING END CLOSURE BREAK NTL -PNT TO MATCH WALL SHIM AS REIXSRED 151 AL TUBE HUSH TO MATCH EXIST. AL AL WINDOW SYSTEM GLAZING TAPE PLAM DOOR W/ CONCEALED HINGES - PLAM ALL EDGES, TYP CABINET INTERIOR OF LOW PRESSURE LAMINATE (WHITE MALAMINE) WIRE PULLS, TYP WALL @ AL WINDOW SCALE: 3 " =1' -0" TYP BASE CABINET 8 SCALE: 3/4 " =1' -0" BRACE AS REQD SUSPENDED CEILING SYSTEM 3 1/2 MTL STUDS 0 16" OC W/ 5/8" GWB 2 LAYERS OF PLYWOOD OVER 5/8" GOB MTL CORNER TYP WALL SURFACING SYSTEM ATTACH PER MFG_ RECOMMAND OVER 5/8" GWB 5/8 GOB WALL 3/4 X 8" OAK BASE PREFIWISH CURT AS READ FINISH FLR DETERMINED BY EXISTING OPENNING WALL SURFACING SYSTEM ATTACH PER MFG. RECOMMANDATIONS OVER 5/8" GWB r 3 1/2 MTL STUDS @ '12 OC WINDOW BELOW COUNTER TOP - OWN SILL BELOW 5/8" GWB EA SIDE OF 3 1/2" MTL STUDS SEE WALL TYPES 1/4" x 1/2" ACOUSTICAL SEALING TAPE FRY # DMEC - 4875 DRY WALL MOLDING' END CLOSURE BREAK MTL -PNT TO MATCH WALL EXISTING WINDOW SYSTEM MULL PLAM COUNTER & BACKSPLASH DRAWER ON FULL EXTENSION GLIDES WIRE PULLS, TYP MELAMINE SHELF ON KV SHELF SUPPORTS PLAM DOOR W/ CONCEALED HINGES - PLAN ALL EDGES, TYP CABINET INTERIOR OF LOW PRESSURE LAMINATE (WHITE MALAMINE) RB, TYP 1/2" FIBER CEMENT BD 3X4 BLOCKING MTL CORNER TYP J MOLD W/ SEALANT, TO EXIST. CONC. CUT FROM 3X4 1/2" FIBER - CEMENT BD 2'- o SINK CABINET 5 SCALE: 3/4' =1' -0" PLAM COUNTER & BACKSPLASH FIXED PANEL WIRE PULLS, TYP SINK PLAN DOOR W/ CONCEALED HINGES - PLAM ALL EDGES, TYP CABINET INTERIOR OF LOW PRESSURE LAMINATE (WHITE MALAMINE) RB, TYP 11 CHAIR RAIL @ EXISTING WINDOW SCALE: FULL 1 1, Gu l u w,vk,vl � ?FRD RPR 2s2.000 BoILDIrNG ONISiOIN SYkTHE ISLLC THE FUSION OF ARCHITECTURE. DESIGN TECHNOLOGY 3 PEOPLE 2353130th Avenue NE, Sells 202 Bellevue, WA 98005 425 8691946 (x)425885 6208 Sssk I)s i ?n A S S O C Interior Planning & Design PHONE 206 236 -7273 FAX 206 236 -1240 rjseeks0B0I.co111 CELL 206 605-1501 4259 EAST MERCER WAY MERCER ISLAND, WA 98040 REVISIONS D2000_ ISSLE NO. DATE MBA PROFESSIONAL STAMP 71, ARCLR:. _ PROJECT INFORMATION KING CO. HOUStNG AUTHORITY TENANT IMPROVEMENTS CENTRAL OFFICE 600 Andover Park West Tukwila, WA 98118 SHEET INFORMATION MEADE FOB. ISSUED FOR PERMIT n r— INTERIOR DETAIL i„ MAR 2 4: 20.00 D ESIGNED er•. JS DRAWN aY. 5 RMfI'CENTER REVIEWED BY. APPROVED BY. uA!O 03/23/2000 SHEET NO. PROJECT NO. 98009.03.000 A a+ . I www.synthesisllc.com O RELITE/DOOR ELEVATION SCALE 1 —1 /2 '-0" 6 1/4" 1 1/2' 1 1/2" 0 RELITE HEAD © CEILING SCALE: 3=1 GLAZING TAPE FINISH CEILING 1 /8"x 1 /8" REVEIL 1 /8"x 1 /8" REVEIL BASE—VARIES FINISH FLOOR 3 1/2" x 1/2" FINISH WOOD SPACER — PAINT TO MATCH FRAME — ATTACH TO CEILING GRID AS REQUIRED FOR FIRM LATERAL ATTACHMENT SUSPENDED CEILING SYSTEM WOOD FRAME 1/8" x 1 /8" REVEL ALL AROUND WOOD STOP 1 1/2" 0 RELITE JAMB SCALE: 3"= 1 '—O" 1 1/2 0 RELITE SILL SCALE: 3"= 1 '-0" 1 1/2' WOOD STOPS—TYP 1 1/2 WOOD STOPS—TYP RELITE © DOOR MULLION SCALE: 3 5/8" GWB OVER 3 1/2" MTh STUD WOOD NAILER AS REQ. 3/4" x 1/2" RABBIT TO RECEIVE 5/8" GWB WOOD FRAME 1/8" x 1/8" REVEIL ALL AROUND 0 WOOD STOPS RELITE WITH GLAZING TAPE (ONE SIDE) RELITE WITH GLAZING TAPE (ONE SIDE) 1/B" x 1/8" REVEIL ALL AROUND 0 WOOD STOPS WOOD FRAME 3/4" x 1/2" RABBIT TO RECEIVE 5/8" GWB WOOD NAILER AS REQ. 5/8 GWB OVER 3 1/2" MTL STUD RUBBER BASE 3/1 6" GLAZING APPROVED GLAZING TAPE OR GLAZING COMPOUND AS SUPPLIED BY GLASS MANUFACTURER 1/4' EDGE CLEARANCE ALL AROUND STEEL FRAME ANCHORS, 3/JAMB MIN 1 1/2 1/2" WOOD STOPS —TYP GLAZING TAPE WOOD STOP 1 /8" x 1/8" REVEIL ALL AROUND 0 RELITE DOOR MULLION SCALE: 0 RELITE MULLION SCALE: 3=1-0" WOOD FRAME WOOD STOP, GLUE & NAIL TO FRAME 1 1/2" WOOD STOPS —TYP RELITE WITH GLAZING TAPE (ONE SIDE) 1/8 x 1/8" REVEIL ALL AROUND 0 WOOD STOPS WOOD FRAME DOOR JAMB (HEAD SIMILAR) SCALE: 3 0" 0 RELITE HEAD @ CEILING SCALE. 3"=1 SEE WALL TYPES WD OR MTL STUD SEALANT CONTINUOUS EACH SIDE STEEL FRAME ANCHORS, 3/JAMB MIN 3 1/2" x 1/2" FINISH WOOD SPACER — PAINT TO MATCH FRAME — ATTACH TO CEILING GRID AS REQUIRED FOR FIRM LATERAL ATTACHMENT ACOUSTIC CEILING TRACK 1/4" EDGE CLEARANCE ALL AROUND APPROVED GLAZING TAPE OR GLAZING COMPOUND AS SUPPLIED BY GLASS MANUFACTURER 3/16" GLAZING 0 RELITE JAMB SCALE. 3 . --0" 5/8" GWB OVER 3 1/2" MTL STUD WOOD NAILER AS REQ. 3/4" x 1 /2" RABBIT TO RECEIVE 5" GWB WOOD FRAME WOOD STOP, GLUE & NAIL TO FRAME 0 DOOR JAMB (HEAD SIMILAR) SCALE 3"=1 '-0" 02000-091 1 /4" EDGE CLEARANCE ALL AROUND APPROVED GLAZING TAPE OR GLAZING COMPOUND AS SUPPLIED BY GLASS MANUFACTURER 3/16" GLAZING 2" 5'0\ THESISLLC THE FUSION OF ARCHITECTURE DESIGN TECHNOLOGY PEOPLE ISSUE NO. DESIGIAED BY. REVIEWED EV. DATE. 2353 130th Avenue NE, Suite 202 Bellevue, WA 98005 425 869 1946 (fax) 425 8866208 (oskt Pssion A E S C I A Interior Planning & Design PHONE 206236=7273 FAX 206 236=1240 rjseeks@aol.corn CELL 206 605-1501 4259 EAST MERCER WAY MERCER ISLAND, WA 98040 REVISIONS DATE PROFESSIONAL STAMP RELME Fos, ISSUED FOR PERMIT nr.. INTERIOR DETAILS maw'. co. 98009.03.000 nal APPROWMB, PROJECT INFORMATION KING CO. HOUSING AUTHORITY TENANT IMPROVEMENTS CENTRAL OFFICE 600 Andover Park West Tukwila, WA 98118 SHEET INFORMATION RECEIVED CITYOR TUKWILA MAR 2 201.41 PERMIT CENIEN JS mum, an STAFF 03/23/2000 SHEET NO A9.2 www.synthesisllc.com tf E NORTH NORTH DI =TAI! /0 CD LOBBY HALL 202 HALL 226 STAIR 230 TELE232 OPEN OFFICE 207 OFFICE ALIGN CONF. 222 DIRECTOR 221 HALL 203 DIRECTOR 206 OFFICE MAINTENANCE & CONST. 211 DEVELOPMENT 216 OFFICE DIRECTOR 217 OFFICE t; CD 0 DIRECTOR ii 107 II j��CGPT -6) Ni " DIRECTOR 103 RENTAL 201 ( RENTAL II 201 SECOND FLOOR CARPET & PAINT LOCATION PLAN SCALE 1/8 " =1 -0" C, r INFORAMTION SERVICES 208 1 J n 174 -0" VERIFY OFFICE 117 OFFICE 134 it OFFICE OFFICE EXECUTIVE OFFICE 122 EXECUTIVE OFFICE 123 BREAK RM_ 124 RESIDENT SERVICES 105 CLOSET H U M{�N RESOURCES 102 LOBBY HALL 101 CO FER HALL 139 ( (PNr -I� I ELEC € L ROOM 144 I WOMEN 0 O 142j TELE 138' MECH ROOM 141 ASST_ DIRECTOR 108 WORK ROOM 113 E \, FILES I! 1 1 1 \ - 1 :4 ------- ----- ,, ,,,e4.- , ._' I I STAIR L -143- (GPT - 5) FIRST FLOOR CARPET & PAINT LOCATION PLAN SCALE: 1/8 " =1' -0" 114 170 VERIFY C4MM. 1 ADMINISTRATIVE SERVICES 116 SEE SHEET 102.3 FOR ENLARGED FLOOR PLAN OF CARPET PATTERNS L_ OFFICE 1, 35 HOUSING MANAGEMENT B 132 OFFICE 1 1 8 00 DIRECTOR 212 00 TOILET 125 l'1 C) 1)2 000 -®y1 GENERAL NOTES FOR PAINT WALL COLORS (PNT) SEE SHEET 102.3 FOR CARPET PATTERNS (CPT) SEE SHEET 102.3 ISSUE NO. 4 SYNTHESISLLC THE FUSION OF ARCHITECTURE DESIGN TECHNOLOGY & PEOPLE REVEWED BY. DATE 2353 130th Avenue NE, Surle 202 Befevue, WA 98005 425 8691946 (fax) 425 885 6208 Suks Pop] ASSOC f A T E S PROJECT N. 98009.03.000 Interior Planning & Design PHONE 206236-7273 FAX 206236-1240 riseeks@aaf.com CELL 206605-1501 4259 EAST MERCER WAY MERCER ISLAND, WA 98040 REVISIONS DATE 03/23/2000 SHEET N. PROFESSIONAL STAMP PROJECT INFORMATION KING CO. HOUSINGAUTHORITY TENANT IMPROVEMENTS CENTRAL OFFICE 600 Andover Park West Tukwila, WA 98118 SHEET INFORMATION RELEASE FOR. ISSUED FOR PERMIT TITHE. INTERIOR FINISH P AAWS'F MMAR s H NE la88M DESIGNED Sy. JS DMWN By. SIl CENTER APPROVED BY. (� ID2.2 www.synthesisllc.com HUMAN RESOURCES 102 NORTH CONFERENCE 109 FIRST FLOOR PLAN CARPET PATTERN PLAN SCALE: 1/8 " =1 -0" 2'x2' GRID LAID FOR THE REFERENCE OF CARPET LAYOUT FINISH SCHDULE SV1 Sheet Vinyl Floors Manufacture: Mannington Commercial Pottern: GLS Series Color: 13400 Installation: all seams except in toilet room are to be chemically welded. Toilet room 125 seams are to be heat weld: Rubber Base MFG: Johnsonite Color: 45 Sandalwood Type: 4" cove -roll stock wi Reduc MFG: Johnsonite Color. 20 Charcoal Types: Carpet to resilient # CM-80 -H Carpet to concrete - #CTA -XX -J EM1 Entry . Mats MFG: Van Disk Carpet, Inc. Pottern: Manhattan Color: Empire Pice: 100% Polypropylene Width: 13 1/2" Installation: Direct glide, butt seams to self and to carpet CPT1 without reducer. CPT1 MFG: Interface Flooring Systems Inc. Pattern: Caribbean II Style: 6607 Color: 3079 Dominica Yarn: 67% DuPont Artron Lumeno, 33% DuPont Artron Legacy Color System: 67% Solution Dyed, 337, Yom Dyed Backing: Glasbac Type: 6 foot wide broadloom Pattern Repeat: Carpet contractor to confirm Pattern Repeat with manufacture to calculate yardage requirements. Lifetime Antimicrobial: - Intersept Soil Stan Protection: Protekt with DuPont Duo Tech Pice Thickness: .138 inches, 3.5 mm Tofted Gouge: 1/12 Pile Density: 6261 Weight Density: 150,261 Installation: Direct Glue Recycle Program.: Interface Reentry Program Represented by: Tim Katzinski (425) 869 -2580 CPT 1 Alternate -Equal - on State. Government Contract MFG: Collins & Aikman Pattern: Custom Pattern, Power Vinyl ,Cushion Style: Custom 9824 -01 Color: Custom to match designers color yam porn selections. Yarn: .100% DuPont Aaron Legacy Color System: 75% Solution Dyed, 25% Yarn Dyed Backing: Powerbond Vinyl Cushion Backing System Type: 6 foot wide broadloom Pattern Repeat: Contractor to confirm Pattem Repeat with manufacture to calculate yardage requirements. Soil Stain Protection: Ensure Pice Thickness: .138 inches,. 3.5 mm Poe Density: 6216 Weight Density: 150,261 Installation:.' Direct Glue Represented by: Tom Petrillo DuPont Flooring Systems (206) 241 -0229 Recycle Program : Collins & Alkman Infinity Initiative Program CPT2 MFG: Mannington Commercial Pattern: Static Color: Cornell (Corn) Yarn: 100% DuPont Artron Legacy Color System: Color Graph Backing: Non - standard - Ultra Bac Plus Type: 12 foot wide broadloom Pottern Repeat: 24 "W x 20 "L Soil Stain Protection:. Duratech. Soil Resistant Treatment Pice Thickness: .172 inches Tufted Yarn . Width: 2603 per yard Density: 5442 installation: Direct Glue Represented by: Tom Petrillo DuPont Flooring Systems (206) 241 -0229 Recycle Program : Manningtion CPT 3 MFG: Mannington Commercial Pattern: Static Color. Ingleridge (Inir) Technical Specifications: Same CPT 2 CPT 4 MFG: Mannington Commercial Pattern: Static Color: Morrison (Mors) Technical Specifications: Same CPT 2 CPT 5 MFG: Mannington Commercial Pattern: Static Color: Carleton (Carl) Technical Specifications: Same CPT 2 h preformed comers CPT 6 MFG: Mannington Commercial Pattern: Static Color: Brooker (Broo) Decorative Modular Wall Panel System Manufacturer: Marlite Product: Surface Systems Four Panel Size: Nominal 24" x 24" x 1/4" Rails and Trim System: Clear Satin Anodized Aluminum Represented by:. David Rupple (425) 672 -8558 Panel Type Plan Codes WPS 1 Faux Wood - SSX -318FT Medium Anigre Faux Print WPS 2 Phosphate Cement SSC- Custom color to approximate Paint Color PT2 WPS 3 Phosphate Cement SSC - Custom color to approximate Paint Color PT3 WPS 4 Phosphate Cement SSC- Custom color to approximate Point :Color PT4 WPS 5 Phosphate Cement SSC- Custom color to approximate Paint Color PT5 WPS 6 SSC- Custom photo panel on plastic foam core Interior Paint Systems PSI - Flat Finish Gypsum Drywall System (Ceilings, soffits only). First Coat: Flat Latex Interior Finish of 1.4 mils OFT Second Coat: Flat Latex Interior Finish at 1.4 mils DFT PS2 - Low - Luster Finish Gympsum Drywall System First Coat: Latex Wall Primer at 1.1 mils DFT Second Coat: Eggshell Acrylic Latex. Enamel at 1.6 mils DFT Third Coat: Eggshell Acrylic Latex Enamel at 1.6 mils DFT Opaque Painted Wood First Coot: Interior Alkyd Undercooter at 1.9 mils DFT Second Coat: Eggshell Acrylic Latex Enamel at 1.6 mils OFT Third Coat: Eggshell Acrylic Latex Enamel at 1.6 mils DFT PS3 - Semi -Gloss Acrylic Latex Enamel (Toilet /Shower only) First Coat: 100% Acrylic Primer at 1.1 mils OFT Second Coat: 100% Acrylic Semi -Gloss at 1.3 mils OFT Third Coat: 100% Acrylic Semi -Gloss at 1.3 mils DFT PS4 Semi -Gloss Enamel Finish Ferrous Metal First Coat: Metal Primer at 3.0 mils DFT (Subject to coating compatibility, repriming of items delivered shop primed is not required.) Second Coot: Semi -Gloss Acrylic Enamel at 1.3 mils OFT Third Coot: Semi -Gloss Acrylic Enamel at 1.3 mils OFT Aluminum First Coot: Semi -Gloss Acrylic Enamel 8 1.3 mils DFT Second Coat: Semi -Gloss Acrylic Enamel at 1.3 mils OFT PS5 - Clear Catalyzed Lacquer (AWI Finish System TR -2) Transparent Finish Wood Doors Color Coot: Wiping Stain and shading, color as selected by Architect. Filler. Natural Filler. Sealer. Lacquer Sanding Sealer. Topcoat: Clear Catalyzed Lacquer, Satin gloss (with shading dyes as needed) 856 Clear. Polyurethane Finish Transparent Finish Architectural Woodwork Color Coat: Wiping Stain and shading, color as selected by Architect Filler: Natural Filler. (Omit on closed grain woods.) First Finish Coat Clear Polyurethane, Gloss Topcoat: Clear Polyurethane, Satin gloss Schedules Interior Point Schedule Surfaces Paint System Gypsum Board - Ceilings U.O.N. P51 Gypsum Board - Walls U.O.N. PS2 Gypsum Board - Toilets /Shower P53 Metals PS4 Wood - Opaque Finish PS2 Wood Doors Transparent Finish P. Wood Work, Architectural Transparent Finish P56 Paint Colors PT1 Parker Paint, 8723M, Desert Tumbleweed All walls unless otherwise noted shall be painted PT1 PT2 Parker Paint, 8286N, Burnt.. All hollow metal door frames including the Elevator Door Fames shall be painted PT2. PT2 is also an accent color for the top and vertical frames flanking the Marlite Panels located at corridor entries to the following departments, First Floor, Administration, Second Floor, Information Services. PT3 Parker Paint, ACt42N, Purple Jazz Accent color for the top and vertical frames flanking the Marlite Panels located at corridor entries to the following departments, First Floor; Residential Services, communications, Second Floor, Maintenance and Construction. PT4 Parker Paint, 84968, Dark Quest Accent color for the top and vertical frames flanking the Modite Panels located at corridor entries to the following departments, First Floor, Housing Management and the Alcove in Hall 139, on Second Floor, Asset' Management. PT5 Parker Paint, 79568, Bacchus Accent color for the top and vertical frames flanking the Marlite Panels located at corridor entries to the following departments, First Floor; Administrative Services, Second Floor; Development. PT6 Parker Paint, 8690W Snow Ballet All gypsum board ceilings and soffits not otherwise noted shall be painted PT6. PT7 Zolotone, Illuminations ZFX -CD 316 PT8 Zolotone, Illuminations, ZFX -BH 439 PT9 Zolotone, Illuminations, ZFX -BA 432 PTIO Zolotone, Illuminations, ZFX -HB 246 PT11 Zolotone, Illuminations, ZFX -CD 208 PT7 shall be used on elevator doors and below choir rail in lobby 100 and Hall 139. Protective Wall Panels PWP1 Plastic Laminate - Nevamar Creme Tranquility Textured TQ -2 -1T PWP1 shall be used in toilet room 125 only for wall protection at toilet. Corner Guards MFG: Bolco Inc. Type: Surface Mounted CGS -2 Color: Sunkissed 147P Size: 2 x 2 x 4' .0" Installation: Mount on top of rubber' base. Lay in Acoustical Ceiling Tile The owners intent to reuse the existing Armstrong Cortege tiles, both ACT 1 and ACT 2 sizes but replace approximately 50 % the total square feet of tile and grid required to complete ceiling areas on both levels. Approximately 50 the existing grid will also be replaced. The contractors should coordinate quantities of file required with owner prior to placing order. ACT 1 MFG: Armstrong Pattern: Cortege 747 Square Edge Size: 24 to 48" x 5/8" Grid: 15/16" wide standard . white ACT 1a (Alternate) This alternate may be used in place of ACT 1 at owners discretion. MFG: Armstrong Pattern: Cortege High NRC, 768, Square Edge Size: 24" x 48" x 3/4" Grid: 15/16" wide standard white ACT2 MFG: Armstrong Pattern: Cortege 704 Angled Tegular Edge Size: 24 +B31 x 24" to 5/8" Grid: 15/16" wide standard white Woad Doors and Frames and Hardware The owner shall specify and purchase all wood doors and frames and hardware. The contractor shall install them.. All wood doors shall be Red Oak veneer. Architectural Woodwork All architectural woodwork including trim, molding, and wood base shall be Red Oak. Cabinetry Countertops, all countertops have self edges and bock splashes. Unless otherwise noted or detailed. All counter tops unless otherwise noted shall be PL1. 36" high transaction counter top at lobby 100 reception counter shall be PL2 with wood edge. Countertops in Conference 109, Break Room 124 and Lounge 223 shall be PL2. Base and Wall Mounted Cabinets All door and drawer edges of all cabinets will receive 3mm plastic edge banding with square corners. Mail boxes in room 102 shall be edged with 1 mm plastic edge banding from wood tape. All cabinets with exposed to view' interiors shall have the interior and shelves faced with the same plastic laminate as the exterior of the cabinet. All interiors of cabinets, shelves and drawers not exposed to view shall be Melamine Interlines in a standard light gray, ' c ontractor to submit samples with shop drawings for .approval. All cabinets unless otherwise noted shall receive plastic laminate PL4. In the following rooms the cabinets shall receive plastic laminate PL3 - Conference 109, Break Room 124, Waiting 224, and 'Lounge 223. Plastic Edge Banding The plastic edge band to be used with plastic laminate PL3 shall be wood .tope 3mm. color 3921 (Wood Grain Pattern). The plastic edge band to be used with plastic laminate PL4 shall be wood tape 3mm, color 6621 White Nebula. Plastic Laminate Schedule PL1 - Plante, Opal Impression, AB121 Suede PL2 - Formica, Golden Shimmer, 7165 -21 Olympus Finish PL3 - Lamin -Art, Royal Annigre Textured, 3022T PL4 - Wilsonart, White Nebula, 4621 -60 Mali Boxes (wall mounted) Room 102 The horizontal shelves within the cabinet body shall be 1/4" thick clear le.') with polished front edge. The 3mm plastic edge band will hold the lexan shelves in place the cabinet body shall be PL4. Cabinet Hardware Hinges: European type, self closing; oll metal including bosses; 75 degree swing except 100 degree swing where cabinet abuts o wall_ Quality as commended by manufacturer for size and weight of door. Blum. Pulls: Metal Pull: Extruded brass wire pulls, 8 mm diameter, 96mm hale spacing, thought bolted from backside. Finish; BHMA ',625, polished chrome. Magnetic Catches: Manufactures standard, 7 pound pull. Drawe- Slides: Cold - rolled steel, zinc plated with steel ball bearing rollers, side mount, full extension slides, with drawer stop device. Standard Drawers - 100 pound rated load capacity, minimum_ Accuride Model 7432 or KV 8400. File Drawers - 150 pound rated load capacity, minimum. Accuride Model 4032 or KV 8500. Adjustable Shelving Supports in Casework: Drill 5 m diameter holes at 32mm on center in vertical lines full height of cabinet interior. Provide metal shelf supports, KV model 345 NP. Cord Grommets Molded plastic 2 -part set for electric cable or wires; body to 6t 60 -mm holes with removable spring closure slotted cop; matte chrome finish. Hafele 429.97.231 or Douge Mockett - #TG_ Contractor to confirm location of grommets during shop drawings. Plan for one grommet for each work surface segment of each counter top. Keyboard Arm, fully articulated low profile, ball bearing slide -guide mechanism, locks in extended position, keyboard rotates 360 degrees, 15 degree tilt, lever activated, 6 inch of spring assisted height adjustment - Hafele Model 639 - 96 Single Post -Leg for Desk/Table Top MFG Doug Marken and Company Inc. Style: TL Series Size: 6" diameter, 27" tall Leveler Glide Leveler adjust to 1 1/4" Color. Matte Black Location: To be located beneath round end of desk top in office 121. Leg should be located in center of round top. Metal Handrail Toi Accessories Gr ab 18 gauge . stainless steel straight bars, concealed mounting, 1.50 -inch diameter, no. 4 Satin Polish finish. G842: Bobrick B -6206 x 42: Locate at Ade of toilet. as shown on elevation. GB36 Bobrick 8 -6206 x 36:' Locate at back wall of toilet, % if as shown on elevation. Elevator Cab 1 - Wall' Panels - New wall panels or existing reeled with plastic 'laminate PL2 - Refer to cabinetry section for plastic laminate color specifications: 2 - Floor - Carpet, CPT1 or CPT' Alternate 3 - Ceiling - . Existing to remain SYNTHS ISLLC THE FUSION OF ARCHITECTURE DESIGN TECHNOLOGY & PEOPLE REVISIONS D2000 -091 ISSUE NO. PROFESSIONAL STAMP BI JILDING DIVISION PROJECT. INFORMATION KING'CO. HOUSING AUTHORITY SHEET INFORMATION RELEASE FOB. ISSUED FOR PERMIT INTERIOR FINISH PLANS ° FINISH SCHDULE criM MAR 2 4 I :))) DESIGNED By. JS DRAWN By STAFF AP PROVED Sy PERMIT CENTER REVIEWED BY. 2353 130th Avenue NE, Suns 202 Bellevue, WA 98005 425 8691946 (fm)425 885 6208 Wks t?siqn S S O CI A E Interior Planning & Design PHONE 206 236 -7273 FAX 206 236 -1240 rjseeks@aol.com CELL 206 605 -1501 4259 EAST MERCER WAY MERCER ISLAND, WA 98040 BATE OEM TENANT IMPROVEMENTS CENTRAL OFFICE 600 Andover Park West Tukwila, WA 98118 Dos. 03/23/2000 SHEET NP PROJECT Ro• 98009.03.000 1D2.3 www.synthesislIc.com