Permit D2000-117 - KRAUSES SOFA FACTORY - RESTROOMS AND LIGHTING
KRAUSE'S FURNITURE D2000-117 . City of Tukwila Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES, APPLICANT IS PROCEEDING AT THEIR OWN RISK. Parcel No: 352304 -9005 Permit No: D2000 -117 Address: 17740 SOUTHCENTER PY St: 01 Status: ISSUED Suite No: Issued: 05/11/2000 Location: Expires: 11/07/2000 Category: ARET Type: DEVPERM Zoning: TUC Const Type: V -N Occupancy: STORE Gas /Elec.: UBC: 1997 Units: 001 Fire Protection: SPRINKLERED /AFA Setbacks: North: .0 South: .0 East: .0 West: .0 Water: TUKWILA Sewer: TUKWILA Wetlands: Slopes: N Streams: Contractor License No: MITCHCI044MN OCCUPANT KRAUSE'S SOFA FACTORY Phone: 17740 SOUTHCENTER PY, TUKWILA, WA 98188 OWNER MBK NORTHWEST Phone: 206 575 -8090 C/O TRAMMEL CROW COMPANY, 17560 SOUTHCENTER PY, TUKWILA WA 98188 F.-z CONTACT ROB KING Phone: 425 - 778 -1921 w 20503 88 AV W, EDMONDS WA 98026 6 D CONTRACTOR MITCHELL CONTRACTORS INC Phone: 206- 463 -5838 v 0 PO BOX 167, VASHON, WA 98070 u) 0 al * k: k*** k*• k• k•******* k** k• k**** k* k*************** k*** k** k** **kkk*k*kk*kk *** * *•k *k * **** *kk* wi F- Permit Description: INTERIOR REMODEL/ RESTROOMS ELECTRICAL SERVICE, CEILING LIGHTING. ** ** * * *** *-k ***•k *•k * * * *•k* * ** * *•k** k*• k********: k*******• k*• k• k• k• k***•** * **•k * **•k*•k•k *•k ***•k* **•k*•k Construction Valuation: $ 180,000.00 PUBLIC WORKS PERMITS: *(Water Meter Permits Listed Separate) Eng. Appr: Curb Cut/Access/Sidewalk/CSS: N Fire Loop Hydrant: N No: Sizefin): .00 Flood Control Zone: N Hauling: N Start Time: End Time: Land Altering: N Cut: Fill: Landscape Irrigation: N Moving Oversized Load: N Start Time: End Time: Sanitary Side Sewer: N No: Sewer Main Extension: N Private: N Public: N Storm Drainage: N Street Use: N Water Main Extension: N Private: N Public: N * **•k k• k********•********• k**• k***** k**************• k*** k****** ** * * * *•k * ***•k*k* * * *•k* * * **** TOTAL DEVELOPMENT PERMIT FEES: $ 2,383.39 : *********************************** k****************** * * * ***k* ** * * **•k* **k* * *•k* * ** *t Permit Center Authorized Signature: Signature: Print Name: DEVELOPMENT PERMIT I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provis "on of ary other state or local laws regulating construction or the performan a war'./ I am authorized to sign for and obtain this development perm This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. !+! Date: S (206) 431 -3670 'Date: i l • CO w g< = d F w z = I- ZO w w Ca 0 ON 0 I- w . I L I O .z w U= OF z Address: 17740 SOUTHCENTER PY St: 01 Permit No: D2000-117 Suite: Tenant: Status: ISSUED Type: DEVPERM Applied: 04/25/2000 Parcel #: 352304-9005 Issued: 05/11/2000 Akki.k************k*AA*%***Ak*AA*A** Permit Conditions: 1. No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 2. Al) permits,-inspection records, •and approved plans shall be available at the job site prior to the start of any con- struction. These documents are to be maintained and avail- able until final inspection approval is granted. 3. Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (248-6630). 4. Plumbing permits shall be obtained through the Seattle-King Countyl Department of Public Health. Plumbing will be inspected by that agency, including all gas piping (296-4722). 5. All mechanical work shall be under separate permit issued by theCity of Tukwila. 6. All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition)', and:Washington State Energy Code (1997 Edition). 7 Validity of Permit. The issuance of a permit or approval of plans, specification, and computations shall not be con striled to' be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to: give authority to violate or cancel the provisions of this code ,shall: be valid. 8. Any new ceiling grid and light fixture installation is required to meet lateral bracing requirements - for Seismic' Zone. 3. 9. Partition walls attached to ceiling grid must be laterally braced if over eight (8) feet in length. CITY OF TUI(WILA .,;.' • - z z W re -J 00 U) 0 W L1J LL aj 0 g u_ CO I I- ILI Z 0 Z 1- L11 uj C.) 0 0 I- UJ LU I 0 Z LU (i) 0 1- z Project Na - KK ct5 k, 7 Value of Construction: / d oo Site Addres : City State /Zip: / 7 > 4' 0 Scc i rtCt - . lu T it.. V 'in.),k 1 M (/ T tAol cIi GA r Tax Parcel Number: 33- -06S.s E''Y` ( 35213 -IC Property wner: i - / ttcSf t2/yi TZG/Z‘ Phone: i- 2oo -s ?2- 8737 Street Address: City State /Zip: 200 N. .sot Zy Sr, 66/1, CA. IZFZ 1 Fax #: / -7/9 990 - 3sF( Contractor: • /*/ 7.ee•74 coNrie/ocre/2S Phone: '6-3 -S' 3 8' Street Address: City State /Zip: PO 4.6X /61, VHT/'e/ ea, 4 8 0 76 Fax #: Architect: • frrat - 6IZC- Phone: 7 /4 5 -0370 Street ,a�ddress : n City State /Zip: 5U 5 C0 .�A . j(,/ZGde /do t4111,4 (4. 97-GZG Fax #: 7/y Y27_ 037s Engineer: Phone: Street Address: City State /Zip: Fax #: Contact Person: /� ieL,Ca*.c); j1‘/1i/7" /50%� Phone: '12S 77 g -f9Z j Street Address: > r4 City State /Zip: 2c2 o3 ge -- 41 4 4 , C 2l i (DS, G✓ `?yOZ6 Fax #: 'f 7 ri- 35zf Description of work to be done: //t/7'£'h ''. 72gkc.I,(J(G /4 �G£ ci7t lc cc 0c E / Ct t o t«- Lt c..wlrir4 Existing use: Retail El Restaurant El Multi-family ❑ Warehouse ❑Hospital El Church ❑ Manufacturing ❑ Motel /Hotel ❑ Office El School /College /University ❑ Other Proposed use: 71 Retail El Restaurant El Multi- family ❑ Warehouse El Hospital ❑ Church El Manufacturing ❑ Motel /Hotel ❑ Office ❑ School /College /University El Other Will there be a change of use? ❑ yes 71 no If yes, extent of change: (Attach additional sheet if necessary) Will there be rack storage? yes gt no �❑rr Existing fire protection features: ICf..sprinklers : automatic fire alarm El none El other (specify) Building Square Feet: /0 existing Area of Construction: (sq. ft.) /b 030 Will there be storage of flammable /combustible hazardous material in the building? ❑ yes fa no Attach list of materials and storage location on separate 8 1/2 X 11 paper indicating quantities & Material Safety Data Sheets CITY OF TUKVLA Permit Center 6300 Southcenter Blvd., Suite 100, Tukwila, WA 98188 (206) 431 -3670 Commercial / Multi - Family Tenant Improvement / Alteration Permit Application Application and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or facsimile. CTPERM1T.DOC 1 /29/97 APPLICANTi`REQUEST:FOR PUBLIC: WORKS SITE/CIVIL `PLARREVIEW OF THE FOLLOWI Addit oval reviews may -bedetermined4y the:Public Departmenf)y .. _,;. ❑ Channelization /Striping ❑ Curb cut/Access /Sidewalk ❑ Fire Loop /Hydrant (main to vault) #: Size(s): El Land Altering 0 Cut cubic yds. 0 Fill cubic yds. El Sanitary Side Sewer #: ❑ Sewer Main Extension ❑ Storm Drainage ❑ Street Use El Water Main Extension ❑ Water Meter /Exempt #: Size(s): 0 Deduct ❑ Water Meter /Permanent # Size(s): El Water Meter Temp # Size(s): Est. quantity: Cl Miscellaneous El Flood Control Zone El Landscape Irrigation O Private 0 Public O Private 0 Public 0 Water Only El Hauling gal Schedule: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date fop icalion accepted: .� -7_. — CO Date p Ilcalion expir s: Application do by: (Initials) PLEASE SIGN BACK OF APPLICATION FORM` ,, L Z w re 00 J = U) u_ w u _ � = W Z I- 1- 0 W ~ O • D- 0 I- W W 0 -O W Z U� t= _ O ~ Z BUILDING OWNEfl TH D AGENT: Signature: Date: ii/Z j Print name: 06 L k Ph fis... -779,-llz Fa Fax - l.7 Y_ 31zI Address � 3�I� ?A5--N 05I IN i` , City/State/Zip f i 6 ALL COMMERCIAUMULTI—IVIILY TENANT IMPROVEMENT /a RATION PERMIT APPLICATIONS ivnosT BE SUBMITTED WITH THE FO OWING: • ALL DRAWINGS TO BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT, STRUCTURAL ENGINEER OR CIVIL ENGINEER • ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN D BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED N/A SUBMITTED ❑ ❑ Complete Legal Description ❑ 171 Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures (Form H -13). Business Declaration required (Form H -10). Four (4) sets of working drawings (five(5) sets for structural work), which include : Z ❑ Site Plan (including existing fire hydrant location(s) 1. North arrow and scale 2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements 3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions 4. Location of driveways, parking, loading & service areas 5. Recycle collection location and area calculations (change of use only) 6. Location and scrpening of outdoor storage (change of use only) 7. Limits of clearing /grading with existing and proposed topography at 2' intervals extending 5' beyond property's boundaries 8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of use only) Z 9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of those, identify by size and species which are to be removed and saved I W 10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change ct of use only) 11. Location and gross floor area of existing structure with dimensions and setback c.) 0 12. Lowest finished floor elevation (if in flood control zone) (I) w 13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form H- _I H 9). u) u- w ❑ ® Floor plan: show location of tenant space with proposed use of each room labeled 2 ❑ 71 Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of u_ any hazardous materials; dimensions of proposed tenant space. = a ❑ ® Vicinity Map showing location of site I-- z i- • ❑ Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack z O layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of w w CI 21 rack. Structural calculations are required for rack storage eight feet and over. v a Indicate proposed construction of tenant space or addition and walls being demolished 0 F- Cl El wW Construction details i i— H ❑ 71 Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of -- 0 water supply to sprinkler vault with documentation from contractor stating supply line will meet or Iii U) exceed sprinkler system design criteria as identified by the Fire Department. v = ❑ SI Washington State Non - Residential Energy Code Data shall be noted on the construction drawings. z ® ❑ SEPA Checklist - if intensification of use (check with Planning Department for thresholds). ® ❑ Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other land use or SEPA decisions. 1 ❑ Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County Department of Public Health prior to submitting for building permit application. The Department of Public Health is located at 201 Smith Tower, Seattle, WA or call (206) 296 -4787. (Form H -5) 71 ❑ Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no contractor has been selected at time of application a copy of this license will be required before the permit is issued OR submit Form H -4, "Affidavit in Lieu of Contractor Registration ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJVR.KBY THE' LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. CTPERMIT.DOC 1/29/97 :� . ron ' , NW/ MEM mum raw *********** * * * * * * * * * (4)6444 *4 - ***** ****7k************* CITY OF TUKWILA, WA'4( f* — " ,�° TRANSMIT **I* * * * * * * * * * * * * * * * * * * ** 4r* * * * * * ** * * * * * * * * *51 * * * * * * * * * ** TRANSMIT Number: R9800271 Amount: 2,383.39 04/25/00 13:22 Payment Method: CHECK Notation: KRAUSE'S FURNITU Init: TLB Permit No: D2000 -117 Type: DEVPERM DEVELOPMENT PERMIT Parcel No: 352304 -9005 Site Address: 17740 SOUTHCENTER PY St: 01 Fl: Un: Total Fees: 2,383.39 This Payment 2,383.39 Total ALL Pmts: 2,383.39 Balance: .00 ********************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Account Code Description Amount 000/322.100 BUILDING - NONRES 1,441.75 000/345.830 PLAN CHECK - NONRES 937.14 000/386.904 STATE BUILDING SURCHARGE 4.50 3762 04/26 970 TOTAL 2383.39 Project: r• ca L,C4 e.-- A of Inspection: K. C- , n ", pe-e- k ...- ■ y r,.L., ( / Address: , . C Li, N €1 -- 7), s 1 LAAJ y Date called: ____ 7 - 0 L.) Special instructions: Date wanted: a.m. 7- IC - e.)e) P.m. Rqq,uester: *ICt v e.n f. eY - ......, INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter B lvd, #100, Tukwila, WA 98188 (206)431-3670 COMMENTS: Ott, 7o Inspect° Date: Approved per applicable codes. El Corrections required prior to approval. El $47. REINSPECT FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: • v.• • -• • . Z CC 6 o c (OW W I cL . W O 2 g u -< to a I- al Z l-0 Z ILI al 2 0 0 - (12 0 1- u i I 0 I- LL Fa' . z O w 0 1— Z Project: - t■ca I ( (— Type of Inspection: Address: 1 7 `:: /hi;(( i4lidv, Date called: 7 7- • Special instructions: ' (q-c ) 1)--Q. 4:141, r-e.... a • 2 ,D' n,- Date wanted: a.m. RequIster: 4a "a-.<::' Phone: 2.0(6 -L/25? 6. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 COMMENTS: za) ;igir 4 ,"2, 1... 64464_ INSPECTION NO. 4 proved per applicable codes. PERMIT NO. (206)431-3670 Corrections required prior to approval. $47.00 REINSPECTIq,aEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter rnvd., Suite 100. Call to schedule reinspection. Receipt No: Date: • COMMENTS: x A l 7 s 2 4J/ � S .,:::', it 41 e_ 7/.5 a / Kam,,.. -) s 5uh,c�vltcr pY Dte d rr ' iio D, 'gC D 0 f) S kl e.A 7-7,-. 5 i'z-,_ ir.4.- bate wanted: 16 -6° 2._) / / f 30.dein '..pie e Zvi r b i ,..1 -- c s ,6 a/ ' / 7 0413 ' , 54,6t / .O/' /11/iN (6 r./t l/ / r/ S6y9 ,54,Gt 4 gi 1. t 1. te, 1 r le I" tee " H lam. ,Gibs ivS (.9-A, L,J 6 f(./ ;2.1 ex, 4l .A�. if- 7202-, N r ject: C�l,a5.S! _Type of Insp ctio : �UEVi CeiJi' 5uh,c�vltcr pY Dte d rr ' iio D, 'gC D 0 Special instructions: bate wanted: 16 -6° p.m. uesterr :: st 0 I ll Inspector, 47 INSPECTION RECORD R etain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 0 Approved per applicable codes. PERMIT NO. (206)431 -3670 Corrections required prior to approval. Date: 7 6 ,.. 0.7 n $47.00 REINSPECT! FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: Z H W J U UO 0 W J H c W 0 Q ' r u_ Na W Z = Z I- W �o 0 1— =W U IL O z 0~ z COMMENTS: Af T . 0 &Lc.. pesp__v(0%.&. Kcgc$-re . C. re-(c.46 ,444erv4C, -eiVt/i tecA) CO .' Peovt V A OCA 1714 6-S 0'01 C. -- -Plate 1-4-64-ci 101 Di D. )14) D 0" / /44/ 7 CeAr/d-S 20$ 6 butycis I uester: ! Vey) .! (36r6r,t_ro-/i64770X( A A . Project: Krai)ce ',S Type of Inspection: 6.egi3Cr (A..- cl C6:- 1 1 1 1-■ , Address: ,. , 11 L K) SI k tQfark-er Vy Date called: (,) — te, - , -- Special instructions: ate wanted: .1 p.m. uester: ! Vey) .! INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 Approved per applicable codes. orrecti require p tor tu approval. Dat T/ j7/& n $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: PERMIT NO. (206)431-3670 (37 COMMENTS: ce /4)0' - 4c , ,,.. , - e.,.... /1 rte, ,-;:,-/ ..dir 5 _,.,,-.) ' o fiLf Y l - ) . ) S 7) Lam-- s �,,e ,-,( ,14 /00 � , 5 7 1-- _6,„ 16 I-tt '4. !.r/// !/ 6 (1ol /. 0/- ./ /i r....,;/ /� Ie:e�t . `60. / "234..,, { .ma 1 4 t )a - 4..�, -�Fe' ,. , l� "- 3 « .rh ��� e%l -, ✓ .i ll., . i __J _ _ / t ` / c ,07 Project: I kfaU's 5 ) Tod of � Type of Inspection: ;n}eF'r�r fravni 1(\yl ic�tn rri Address: ► - q 9 Iri etil�d R <Y, Date calked: (t)I400 Special instructions: ! Date wanted: ( 100 p.m. Requester: Phone: _ Pan_hR I - .1- hq INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter :Blvd, #100, Tukwila, WA 98188 Approved per applicable codes. Inspector: _ .4 / - $47.00 REINSPECTIO FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: INSPECTION RECORD Retain a copy with permit Corrections required prior to approval. Date: PERMIT NO. (206)431 -3670 • 3 COMMENTS: p 1'i .. iS )tJoT j Q /1r S TmLC. Die, 14-Pr .9m PS Pg6 /q' 7- 0n1C CWdt(ccA-C X $P,4c&S� toot Cb c.CS71at/C77o' x( 0 Rk' YI'1 E.. rE,.L01.0 )1 W,,4C vii !`rs - 4i- & /,./ t-t-c De--7 4 2 /nQ - °L TD /ll suLAT - `JAL Pt'e TX1(Z -- ,CIabcei (' - &COB Ox.M.. S 1 <cv r C,e. cr (c /Q�i�/�-�`'1/.�, L. equrt Phone: Pro ect: 'P s ,-_,r 1---1 T of Inspection: inn o(1hi.1 ol r ss halw Pr ate called: 00 Special instructions: Date wanted:_ ^ equrt Phone: '-j INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd, #100, Tukwila, WA 98188 PERMIT NO. (206)431 -3670 El Approved per applicable codes. Corrections required prior to approval. a 470 $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No: Date: 'ta..as�. �b i �':i:.'.�tiiL�,:..'ti: gala:, �i. �... a:: S::..... �1..±.", �.._._ Cr. a...._.:. c::.. 1.:..=. u:,.: a+.:.:.:-.. �. w.x..w:2.c..•__.....�.....�.... s.,.....;;� • z Z Q � JU U W w I 2 LL w g5 LL. gl a I- al z � Zo W � o = IL /6 w z p z O ~ z trn:.ciasu a.;a. u✓:Le:'.iswu. «..u:1 •:C.±c.:YS ri;S:.U. ii. w:r:ia.+.u.:ca.:M..yr. • . .. '+.+gym »:_,.._ .w•- ,.+e:.a � . � k� t r. ;is � . i �•� °j s rf'.:.. . �. .:r..'ts•dr:- d"�•,��"' °"' "•Y'� ::; .� !Ft ^ is . r.�!:.� City of Tukwila Fire Department TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM r Project Name 17 /a" u S ,E 5 5 �-�'► f' 7 „i2 Address X77 U `: G •P Y � Retain currentAns.pection schedule Needs shift inspection Y Approved without correction notice Approved with correction notice issued Sprinklers: 5 Fire Alarm: 4 Hood & Duct: ,C/ Halon: n1 Monitor: �.,� // Pre -Fire: Permits: Authorized Signature FINALAPP.FRM d Steven M Mullet, Mayor Thomas 1? Keefe, Fire Chief Permit No. I >oer - /1 Suite # -.7 Da Rev. 2/19/98 ti T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206-575-4404 • Fax: 206-575-4439 #; w re 2 J U 00 0 W= I- w gQ CO d = IW z � w� w U ON OH W LL z Ui = O z • d - 27 -2000 6:16AM FROM WW-db -fib 11:41 4/26/2000 Mitchell Contractors P.O. Box 167 24234 129 Ave. SW Vashon WA. 98070 Attention: Mr. Ron Mitchell Dear Ron, ATR Engineering Inc. 9929 SV/ 20618 CT Vadim WA. 98070 (206) 463 -5738 Sybjpt. Parkway Supercen e r / Krause Furniture New mechanical units _�� �,�_r•r1 .Rwt 4 " D ZQOO —1 t n � I have reviewed the existing structural system and the impact new mechanical units would have on it. My analysis indicates that 4ton mechanical units placed in alternate bats would be acceptable. (See sketch for unit location). Additional beams would have to be placed under the existing structure to accommodate the new mechanical units. Please note that the existing glued - laminated beams are stressed in bending to their maximum capacity with an assumed additional load due to new Batt insulation of 3 - 1/2 inches thickness. In other words care must be taken not to introduce any additional dead toads onto the framing system other than the new mechanical and the additional ban insulation. If you have any question regarding this information please feel free to call. Sincerely. Arthur T. Rack P.E. Principal (3tfrs 1 1 7 P.01 RECEIVED CITY OF 7UKWILA APR 2i 2000 PERMIT CENTER P. 1 .: z w 6 UO to 0 w= � LL. w g a co � = I- _ Z � ►= Z t- w uj 2 o w uj u. O .. Z U O z Lt-27-2� 6:16AM FROM Zb-.621147 1 1 • <I ATR Enamoring Consulting Engineer 9929 SW 206th Ct. Vashon, WA 96070 phone: (206) 483-5735 • smem.edbip■momi■■■ _ •••■• z z u-i 6 D _1 0 • 0 CO 0 W Ui - J • u., ill 0 g LL. I • a I- ILI Z I- 0 Z ° U 0- 0 LU LU u i U_ 1 6 Z 0 0 Project Info Project Address 40415 -(Is 174/ma node. Allowed Watts per ft " F,VC- ...---" 3 /I . *t (1- F Department Usek - "' Cl OF TUKWiLA t _� it PEM.411 CENTER /.12 y0 50.c 772. e,a y E T/ct-i 4 S• ,w Ar 2 crb rt _.,,. /06 3 v /50 �• Zt °( Applicant Name: _ . , kia R*5r••ack.) rA s . °"' Outdoor Areas �� Applicant Address : 7 spa �hVr J 1 �'',f}` vlt(3 ( CN S , [C4E7anrtAf -24?Te 5513 ? Applicant Phone 75" -') t =- /12 / 5 8 '/ /(o Location (floor /room no.) Occupancy Description Allowed Watts per ft " Area in ft Allowed x Area Rcff, �at�S E T/ct-i 4 S• ,w Ar 2 crb rt /,, /06 3 v /50 'iit .K- I-ic1N Zt °( £ R*5r••ack.) rA s - ,.11 0 / * N S'rtiarucV mc......T Outdoor Areas r 0.2 W/tt [C4E7anrtAf -24?Te 5513 ? W, • 5 8 '/ /(o Bldg. (by perim) 7.5 Will Alteration Exceptions (check appropriate box) CI No changes are being made to the lighting [I Less than 60% of the fixtures are new, and installed lighting wattage is not being increased Location (floor /room no.) Fixture Description t,, r_ l.1 -1MtA t4 k. 3 PR Number of Fixtures Watts/ re/ Fixture Watts Proposed 3'')*4V a' / o qSC f/ Rcff, �at�S z -itmP Ti2ort t � z CPL. 110 ss�,z7) 6 S 5 0' if Gpct`( .S'trt.a 'iit .K- I-ic1N Zt °( £ R*5r••ack.) rA s - ,.11 0 / * N S'rtiarucV mc......T Outdoor Areas r 0.2 W/tt [C4E7anrtAf -24?Te 5513 ? W, • 5 8 '/ /(o Bldg. (by perim) 7.5 Will Note: for building exterior, choose either the facade area or the perimeter method, but no both) Total Allowed Watts Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts X56 /D // Location - Description Allowed Watts per it or per If Area in ft (or If for perimeter) Allowed Watts x ft (or x If) Covered Parking 0.2 W/H Open Parking 0.2 W/ft Outdoor Areas 0.2 W/tt _ Bldg. (by facade) 0.25 W/ft Bldg. (by perim) 7.5 Will Note: for building exterior, choose either the facade area or the perimeter method, but no both) Total Allowed Watts Location Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Total Proposed Watts may not exceed Total Allowed Watts for Exterior Total Proposed Watts D7 non - I 17 1997 Washinstrt\State Nonresidential Ener Lighting Summary LTG-SUM at Edition • Ju 1997 Washington State Nonresidential Energy Code Compliance Forms Project Description l ❑ New Building ❑ Addition Alteration Compliance Option ❑ Prescriptive ❑ Lighting Power Allowance ❑ Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Use mfgr listed maximum input wattage. For fixtures with hard -wired ballasts only, the Maximum Allowed Lighting Wattage (Inters default table in the NREC Technical Reference Manual may also be used From ab le 15-1 (over) - document all exceptions taken from footnotes Proposed LiEhtine WattaEe (Exterior Code Com liance �•+rm Proposed Lighting Wattage (Interior) (May not exceed Total Allowed Watts for Interior) Total Allowed Watts Use mfgr listed maximum input wattage. For fixtures with hard -wired ballasts or>j(r, the Proposed Lighting Wattage (Exterior) (May not exceed Total Allowed Watts for Exterior) /50y 1998 Z 1 Z w QQ JU O 0 to co J M W O 2 uQ = • d F W Z � I— O Z W • W U � O � O H- =W F- �5?i u_z Pt() r.3 F= _ o F- Z Og Mechanical - General Requirements 1997 Washin ton State Nonresidential Eners Code Corn •liance Form Mechanical Perm r lans Checklist 1997 Washington State Nonresidential Energy Code Compliance Forms MECH -CHK Flrat Edition -June 1998 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown in Table 14 -1 through 14 -3. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures aids', data shall be furnished by the equipment manufacturer. 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124.1991. Storage water heaters used In combination space heat and water heat applications shall have either an Energy FActor (EF) or a CAE 1411.4 Packaged Electric Heating and Cooling Equipment: Packaged electric equipment providing both heating and cooling with a total cooling capacity greater than 20,000 Btu/h shall be a heat pump. Exception: Unstaffed equipment shaefiers orcabineb used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shal be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a build h g shall be considered as a separate zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees Fwihin which the supply of heating and cooing energy to the zone ls shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buidings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooing thermostat setpoinb are set to the same temperature between 70 degrees F and 75 degrees F Inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or alternate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven diferent day types per week. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full bad demands of 2 kW (6,826 Btu/h) or less may be controlled by readiy accessble manual off -hour controls. 14124.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon powerfaiure. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion airintakes. 14125 Heat Pump Controls: Unitary air cooled heat pumps shal include microprocessor controls that minimize supplemental heat usage during start -up, sat -up, and defrost conditions. These controls shall anticipate need for heat and use compression heating as the first stage d heat. Controls shall indicate when supplemental heating is being used through visual means (e.g., LED indicators). 1412.8 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu/h shal have modulating or staged combustion control. Exceptions: 1. Boilers. 2. Radiant Heaters. 14127 Balancing: Each air supply outlet or air or water terminal device shal have a means for balancing, Including but not limited to, dampers, temperature and pressure test connections and balancing valves. 1413 Alr Economizers 1413.1 Operation: Air economizers shat be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. 1413.2 Control: Air economizers shall be controlled by a control system capable of determining If outside air can meet part or al of the buiding's cooing loads. 1413.3 integrated Operation: Building Heating Energy: Air economizers shal be capable of providing partial cooling even when additional mechanical cooing is required to meet the remainder of the cooing load. Controls shall not preclude the economizer operation when mechanical cooling is required simultaneously. Exception: Economizers on individual, direct expansion, cooling systems with capacities not greater than 75,000 Btu/h may inciu controls that limit simultaneous operation of the economizer and mechanical cooling for the purpose of preventing ice formation on cooling coils. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 Inch water column static pressure shall be sealed in accordance with Standard RS-18. Extent of sealing required is as folows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse Joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse Joints and longitudinal seams. 3. Static pressure: above 3 inches: seal all transverse Joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shat not be used as the primary sealant where ducts are designed to operate at static pressures of 1 inch W .C. or greater. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the buiding envebpe, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements include insulation Installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air buyers must be isolated from the conditioned space by insulating surfaces to a minimum o f R -11 and any exterior envelope surfaces per Chapter 1 3. Outside air duct runs are cons bared building envelope until they, a. connect to the heating or cooling equipment, or b. are isolated from the exterior with an automatic shut -off damper Once outside air ducts meet the above fisted requirements, any runs within conditioned space must comply with Table 14-5 requirements. Other duds and plenums shat bethermaly insulated per Table 14-5. Exceptions: 1. Within the HVAC equipment. 2. Exhaust air ducts not subject to condensation. 3. Exposed ductwork within a space that serves that space only. 1415 Piping Systems 1415.1 Insulation: Piping shall be thermaly insulated in accordance with Table 14-6. Exception: Piping instaled within unitary HVAC equipment. Water pipes outside the conditioned space shall be insulated In accordance with Washington State Plumbing Code (W AC 51 -26) 1420 SIMPLE SYSTEMS (PACKAGED UNITARY EQUIPMENT) 1421 System Type: To qualfy as a simple system, systems shall be one of the following: 1. Air cooled, constant volume packaged equipment, which provide heating, cooling a both, and require only external connection to duct work and energy services. 2. Air cooled, constant volume spit systems, which provide heating, cooling or both, with cooling capacity of 84,000 Btu/h or less. 3. Heating only systems which have a capacity of less than 5,000 cfm or which have a minimum outside air supply of less than 70 percent of the total air circulation. All other systems shal comply with Sections 1430 through 1438. 1422 Controls: In addi to the control requirements in Section 1412, where separate heating and cooing equipment serve the same temperature zone, thermostats shal be Interlocked to prevent simultaneous heating and cooling. Systems which provide heating and cooling simultaneously to a zone are prohibited. 1423 Economizers: Economizers meeting the requirements of Section 1413 shat be instaled on single package unitary fan-cooling units having a supply capacity d greater than 1,900 dm or a total cooling capacity greater than 54,000 Btu/h. The total capacity of al units without economizers shat not exceed 24 0,00 0 Btu/h per building, or 10% of its aggregate cooling (economizer) capacity, whichever is greater. 1424 Separate Alr Distribution Systems: Zones with special process temperature requirements and /or humidity requirements shall be served by separate air distribution systems from those serving zones requiring only comfort conditions. EF CAE < 50 gal storage 0.58 0.71 50 to 70 gal storage 0.57 0.71 > 70 gal storage 0.55 0.70 Mechanical - General Requirements 1997 Washin ton State Nonresidential Eners Code Corn •liance Form Mechanical Perm r lans Checklist 1997 Washington State Nonresidential Energy Code Compliance Forms MECH -CHK Flrat Edition -June 1998 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown in Table 14 -1 through 14 -3. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures aids', data shall be furnished by the equipment manufacturer. 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124.1991. Storage water heaters used In combination space heat and water heat applications shall have either an Energy FActor (EF) or a CAE 1411.4 Packaged Electric Heating and Cooling Equipment: Packaged electric equipment providing both heating and cooling with a total cooling capacity greater than 20,000 Btu/h shall be a heat pump. Exception: Unstaffed equipment shaefiers orcabineb used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shal be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a build h g shall be considered as a separate zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees Fwihin which the supply of heating and cooing energy to the zone ls shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buidings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooing thermostat setpoinb are set to the same temperature between 70 degrees F and 75 degrees F Inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or alternate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven diferent day types per week. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full bad demands of 2 kW (6,826 Btu/h) or less may be controlled by readiy accessble manual off -hour controls. 14124.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon powerfaiure. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion airintakes. 14125 Heat Pump Controls: Unitary air cooled heat pumps shal include microprocessor controls that minimize supplemental heat usage during start -up, sat -up, and defrost conditions. These controls shall anticipate need for heat and use compression heating as the first stage d heat. Controls shall indicate when supplemental heating is being used through visual means (e.g., LED indicators). 1412.8 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu/h shal have modulating or staged combustion control. Exceptions: 1. Boilers. 2. Radiant Heaters. 14127 Balancing: Each air supply outlet or air or water terminal device shal have a means for balancing, Including but not limited to, dampers, temperature and pressure test connections and balancing valves. 1413 Alr Economizers 1413.1 Operation: Air economizers shat be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. 1413.2 Control: Air economizers shall be controlled by a control system capable of determining If outside air can meet part or al of the buiding's cooing loads. 1413.3 integrated Operation: Building Heating Energy: Air economizers shal be capable of providing partial cooling even when additional mechanical cooing is required to meet the remainder of the cooing load. Controls shall not preclude the economizer operation when mechanical cooling is required simultaneously. Exception: Economizers on individual, direct expansion, cooling systems with capacities not greater than 75,000 Btu/h may inciu controls that limit simultaneous operation of the economizer and mechanical cooling for the purpose of preventing ice formation on cooling coils. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 Inch water column static pressure shall be sealed in accordance with Standard RS-18. Extent of sealing required is as folows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse Joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse Joints and longitudinal seams. 3. Static pressure: above 3 inches: seal all transverse Joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shat not be used as the primary sealant where ducts are designed to operate at static pressures of 1 inch W .C. or greater. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the buiding envebpe, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements include insulation Installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air buyers must be isolated from the conditioned space by insulating surfaces to a minimum o f R -11 and any exterior envelope surfaces per Chapter 1 3. Outside air duct runs are cons bared building envelope until they, a. connect to the heating or cooling equipment, or b. are isolated from the exterior with an automatic shut -off damper Once outside air ducts meet the above fisted requirements, any runs within conditioned space must comply with Table 14-5 requirements. Other duds and plenums shat bethermaly insulated per Table 14-5. Exceptions: 1. Within the HVAC equipment. 2. Exhaust air ducts not subject to condensation. 3. Exposed ductwork within a space that serves that space only. 1415 Piping Systems 1415.1 Insulation: Piping shall be thermaly insulated in accordance with Table 14-6. Exception: Piping instaled within unitary HVAC equipment. Water pipes outside the conditioned space shall be insulated In accordance with Washington State Plumbing Code (W AC 51 -26) 1420 SIMPLE SYSTEMS (PACKAGED UNITARY EQUIPMENT) 1421 System Type: To qualfy as a simple system, systems shall be one of the following: 1. Air cooled, constant volume packaged equipment, which provide heating, cooling a both, and require only external connection to duct work and energy services. 2. Air cooled, constant volume spit systems, which provide heating, cooling or both, with cooling capacity of 84,000 Btu/h or less. 3. Heating only systems which have a capacity of less than 5,000 cfm or which have a minimum outside air supply of less than 70 percent of the total air circulation. All other systems shal comply with Sections 1430 through 1438. 1422 Controls: In addi to the control requirements in Section 1412, where separate heating and cooing equipment serve the same temperature zone, thermostats shal be Interlocked to prevent simultaneous heating and cooling. Systems which provide heating and cooling simultaneously to a zone are prohibited. 1423 Economizers: Economizers meeting the requirements of Section 1413 shat be instaled on single package unitary fan-cooling units having a supply capacity d greater than 1,900 dm or a total cooling capacity greater than 54,000 Btu/h. The total capacity of al units without economizers shat not exceed 24 0,00 0 Btu/h per building, or 10% of its aggregate cooling (economizer) capacity, whichever is greater. 1424 Separate Alr Distribution Systems: Zones with special process temperature requirements and /or humidity requirements shall be served by separate air distribution systems from those serving zones requiring only comfort conditions. Lighting Permit Plan 1997 Washington State Nonresidential Energy Code Compliance Forms hecklist LTG -CHK First Edition - June 1998 Project Address Date The following information is necessary to check a lighting permit application for compliance with the lighting requirements in the 1994 Washington State Nonresidential Energy Code. Applicability (circle) Code Section Component Information Required Location on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) MI no a. a. 1513.1 Local controVaccess Schedule with type, indicate locations MI no a•a• 1513.2 Area controls Maximum limit per switch 1513.3 Daylight zone control Schedule with type and features, indicate locations yes no n.a. vertical glazing Indicate vertical glazing on plans yes no n.a. overhead glazing Indicate overhead glazing on plans yea no a.a. 1513.4 Display /exhiWspecial Indicate separate controls 1513.5 Exterior shut -oft Schedule with type and features, indicate location yea no n.a. (a) timer w/backup Indicate location yea no n.a. (b) photocell. Indicate location 1513.6 Inter. auto shut -off Indicate location Yea ao n.a. 1513.6.1 (a) occup. sensors Schedule with type and locations yea ao n.a. 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans LIGHTING WATTAGE (Sections 1520 -22 or 1530-32) yea no Lighting Sum. Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture ELECTRIC MOTORS (Section 1511) yes AO n.a. 1E0c motor efficiency MECH -MOT or Equipment Schedule with hp, rpm, efficiency 1997 Washington State Nonresidential Energy Code Compliance Form no Is circled for any quest on, provide explanation: it s M711,4lCnvtxfnPMxct .w.mrerv...,.,T'M'< : art r twa' em. z'+^ .xw.cuun • ,..��,.._.....,. « +, rw,rfr>r rca!^ sr K?Y ; Yd, n1 ! y�R^M".akT'k33r'- ti.5"ak4lt�Vgf Z W re D U0 to CO ILI J H w LLQ = I— w Z = .. l- 0 Z F- w 7 o 0 0- I 0 H I- -O LU U= 01- Lighting - General Requirements 1513 Lighting Controls 1513.1 Local Control andAcoeseibility: Each space, enclosed by walls or ceiling- height partitions, shall be provided with lighing controls located within that space. The lighting controls, whether one or mores shall be capable of turning off all lights within the space. The controls shall be readily accestsible, at the point of entry/exit, to personnel occupying or using the space. Exceptions: The fdlowing lighting controls may be centralized in remote locations: 1. Lighting controls br spaces which must be used as awhde. 2. Automatic controls. 3. Controls requiting trained operators. 4. Controls for safety hazards and security. 1513.2 Area Controls: The maximum lighting power that may be controlled from a single switch or automatic control shall not exceed that which is provided by a twenty ampere circ tit loaded to not more than eighty percent. A master control may be installed provided the indi swtches retain their capadlityto function independently. Circuit treakers may not be used as the sole means d switching. Exceptions: 1. Industrial or manufacturing process areas, as may be required for production. 2. Areas less than five percent of the building footprint forfootprints over 100,000 ft 15133 Daylight Zone Control: All daylighted zones, as defined in Chapter 12, both ;rider overhead glazing and adjacent b vertical glazing, shall be provided with incividual controls, or daylight- or occupant- sensing automatic controls, which control the lights independent of general aea I ghting. 1513.4 Display, Exhibition, and Specialty Lighting Controls: All cisplay, elhibition, or specialty lighting shall be controlled independently of general area lighting. 1513.5 Automatic Shut -off Controls, Exterior. Exterior lighting not intended for 24 -hour continuous use shall be automatically switched by timer, photocell, ora combination of timer and photocel . Automatic time switches shall also have 1997 Wash ~ gton State Nonresidential Ener• Code Corn • ce Form Lighting Permit PI. s Checklist 1997 Washington State Nonresidential Energy Code Compliance Forms LTG -CHK First Edition -June 1998 program back -up capabilities, which prevent theloss of program and time settngs for at least 10 hours, if power is interrupted. 1513.6 Automatic Shut -Off Controls, Interior: Office buildngs greater than 25,000ft all school dassrooms shall be equipped with separate automatic controls to shut off tie lighting during unoccupied hours. Automatic contrds may be an occtpanty sensor, time switch, a other device capable of attomatically shutting off I ghting. Exceptions: 1. Areas that must be continuously illuminated, or illuminated in a manner regtiring manual operation of the lighting. 2. Emergency lighting systems. 3. Switchng for industrial or manufacturing process fadlities as may be required forproduction. 15136.1 Occupancy Sensors: Occupancy sensors shall be capable of automatically tuning off all the lights in an area, no more than 30 minutes after the area has been vacated. 1513.12 Automat icTime Switches: Automatic time switches shall have a minimum 7 day clock and be capable of being set for7 different day types per week and incapaate an aromatic holiday 'shut-off" feature, which turns off all loads for at least 24 hours and then resumes normally scheduled operations. Automatic time switches shall also have program back -up capabilities, which prevent the loss of program and time settings for at least 10 hours, if power is interrupted. Automatic time switches shall incorporate an over -ride switching device which: a. is readilyaccesstble; b. is located so that a person using the device can see the lights or the areas cortrolled by the switch, or so that tha area being illuminated is annunciated; c. is manually operated; d. alows the lighting to remain on for no more than two hours when an over -ride is initiated; and e. controls an area not exceeding 5,000 ft 2 5 percent of footprint forfootprirts over 100,000 ft whichever is greater. Use' LPA (W /ft Use' LPA (W /ft Painting, welding, carpentry, machine shops 2.3 Police and fire stations 1.2 Barber shops, beauty shops 2 Atria (atriums) 1 Hotelbanquet /conference /exhibitionhall 2 Assembly spaces auditoriums, gym nasia theaters 1 Laboratories 2 Process plants 1 Aircraft repair hangars 1.5 Restaurants /bars 1 Cafeterias fast food establishments 1.5 - ,' 1 Factories, workshops, handling areas 1.5 Retail B Retail bankina = 1.5 Gas stations, auto repair shops 1.5 Locker and /or shower facilities 0.8 Institutions 1.5 Warehouses", storage areas 0.5 Libraries 1.5 Aircraft storage hangars 0.4 Nursing homes 1.5 Parking garages Si Soothe 1532 W holesale stores (pallet rack shelving) t.5 Mall concourses 1.4 Plans Submitted for Common Areas Only' Schools buildings, school classrooms, day care centers 1.35 Com mon area, corridors, lobbies (except mall concourse) 0.8 Laundries 1.3 Toilet facilities and washrooms 0.8 Office buildings, office/administrattve areas in facilities of other use types (Including but not lim iced to schools, hospitals, institutions, museums, banks, churches)"'" 1.2 Prescriptive Spaces Occupancy ❑ Warehouses, storage areas or aircraft storage hangers ❑ Other Qualification Checklist Note: If occupancy type is 'Other and fixture answer is checked, the number of fixtures in the space is not limited by Code. Clearly Indicate these spaces on plans. If not qualified, do iPA Calculations. Lighting Fixtures: ❑ Check here if at least 95% of fixtures In the space meet all four criteria: 1. Fixtures are fluorescent, non - lensed, with only one or two lamps, and 2. Lamps are T -5, T-6, T -8 or PL, and 3. Lamps are 5-50 Watts, and 4. Ballasts are electronic ballasts Lighting Summary : ck) LTG -SUM 1997 Washington State Nonresidential Energy Code Compliance Forms Table 15 -1 Unit Lighting Power Allowance (LPA) for Interior Lighting 1. In cases in which a use is not mentioned specifically, the Unit PowerAllntuance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2. The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3. Watts per square foot of room maybe increased by two percent per foot of ceiling height above twelve feet. 4. For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5. Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6. Includes pump area under canopy. 7. In cases in which a lighting plan is submitted for only a portion of a floor, a Unit Lighting Power Allowance of 1.35 may be used for usable office floor area and 0.80 watts per square foot shall be used far the common areas, which may include elevator space, lobby area and rest rooms. Common areas, as herein c}efined do not include mall concourses. 8. For the fire engine room, the Unit Lighting Power Allowance is 1.0 watts per square foot. 9. For indoor sport tournament courts with adjacent spectator seating, the Unit Lighting Power Allowance for the court area is 2.6 watts per square foot. 10. For both Retail A and Retail B, light for free - standing display, building showcase illumination and display window Illumination installed within two feet of the window are exempt Retail A allows a Unit Lighting Power Allowance of 1.0 watts per square foot. Ceiling mounted adjustable tungsten halogen and HID merchandise display illuminaries are exempt. Retail B allows a Unit Lighting Power Allowance of 1.5 watts per square foot, including all ceiling mounted merchandise display luminaries. 11. Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. .7 ''°4 4',4 : 3trrt(n, nt'1, t£9.1(Px'N y cr , ',V rr.+. Y,gro,`. 7 _.r1•ry,,,.., r, /n:-, ;,ycn 1997 Washington State Nonresidential Ener Code Com M (lance Form Footnotes for Table 15.1 First Edition • June 1996 1997 Wast*gton State Nonresidential Ener Code Corn •ice Form Lighting Power All b ance Adjustments LTG -LPA 1997 Washington State Nonresidential Energy Code Compliance Forms Adjusted Lighting Power Allowances (Interior) First Edition - June 1998 Project Address rate / // ,(/� I z` Use this form if you are claiming any ceiling height adjustments for your Lighting Power Allowances for interior lighting. The Occupancy Description should agree with the, 'Use' listed on Code Table 15-1._ Identify the appropriate Ceiling Height Umit (9 feet, 12 feet or 20 feet) on which the adjustment is based. The Adjusted LPA is calculated from this number and from the Allowed Watts per square foot. Carry the Adjusted LPA to the corresponding 'Allowed Watts per it location on LTG -SUM. 2AU_S�S /ratzivr 7e?,(' -- - Location (floor /room no.) Occupancy Description Allowed Watts per ft Ceiling Height for this room Ceiling Height limit for this exception" Adjusted LPA Watts per ft From Table 15-1 based on exceptions listed In footnotes z 1 z W 1 O 0 CO O W J WO 2 g Q 3 I— W Z � I— O Z 1— W ill U � O N OH = W I— H LL- O . z Ui U s2 p _ O ~ z R. C. Construction & Management Inc, Mr. Ken Nelson City of Tukwila, Dept. of Community Dev. 6300 Southcenter Blvd. #100 Tukwila, WA. 98188 Dear Ken: R. C. Construction & Management Inc. 20503 88th Av. W. Edmonds, WA. 98026 April 24, 2000 Subject Construction Permit, Krause's Furritture @ Parkway Supercenter, Tukwila WA. "MMaelrington State Nonresidential Energy Code Compliance Form" and general explanation of remodel I have filled out the WSECF relative to the work being undertaken at the Krause's Furniture location in Parkway Supercenter. The Architect (hired by Krause's) is in southern California, and is unfamiliar with the forms required by jurisdictions here in Washington. That combined with the relative simplicity of the remodel, as it relates to building envelope, has caused me to explain our efforts with this letter. The initial calculations for lighting at Krause's did not comply with the 1.5 watt per foot maximum listed in the state energy compliance form. I did a fixture change for wattage reduction and accomplished the desired results, but then the lighting in the space was below the minimums Krause's requires to sell pis. A second approach used their designed fixtures and relates to the current use, rather than meeting a watt per foot maximum. This method gives the light required by the tenant, and reduces the energy use from current rent consumption by 58% This approach accomplishes the spirit of the code and compliance, and gives the retailer light levels for optimum retail sales of their products. It also keeps the total wattage to under 2 watts per foot. (1.94 watts/ft.) In general, Krause's is reducing the size of their retail showroom in the center. They are transferring the reduced space footage to the Bon Marche, who will remodel that area under a separate construction permit The new smaller space remodel will include a T -bar ceiling, repaint and carpet Lighting change, new restrooms and a break room. No building shell alteration will take place, so the envelope will remain "as is" except for the installation of roof insulation under the deck That insulation will fill the cavity of the Berkley Panel roof structure, and be faced with vinyl. Electrical, Mechanical, Plumbing, and Sprinkler will be "Bidder Design" so each subcontractor will apply for their respective permits when the design drawings are complete. Please contact me at once if the energy information provided is unacceptable. I look forward to your input and comments ASAP so we can get this remodel completed. CIS OF RECEIVED NPR 252000 PERMIT CEPITEH P z000 ii7 z 1 w ix JU 00 CO 0 CO w 0 2 g Q = d: F w Z = I— 0 zr— w uj M p U O F- WW � u. O. w z U= O~ z 3 NOTICE: IF THE DOCUMENT IN THIS FRAME IS LESS CLEAR THAN THIS NOTICE IT IS DUE TO THE QUALITY OF THE DOCUMENT. _ OCT 30 '00 17 19 FR TRAMMELL CROW CO 11'a111111dll (.rO\VCOIllpaily RECEIVED October 30, 2000 OCT 31 2000 COMMUNITY DEVELOPMENT Duane Griffin CITY OF TUKWILA Building Division 6300 Southcenter Boulevard Tukwila, Washington 98188 Re: Parkway SuperCentor— Tukwila, Washington Krause's Furniture: Permit #D2000-11T Dear Duane, 206 575 4140 TO 4313665 P.01/02 Via Facsimile (206) 4Z1 -3665 Thank you for clarifying the City of Tukwila's viewpoint regarding Certificates of Occupancy. I appreciate your time and consideration over the phone this afternoon. It is my understanding that the City of Tukwila does not typically issue new Certificates of Occupancy for tenant remodels. Although there is no previous /existing Certificate of Occupancy on record for the Krause's Fumiture space, it is also my understanding that the City of Tukwila has not deemed it necessary to issue a new one at this time. The final Inspection Record dated 07/10/00 which clearly states "OK to final" is the City of Tukwila's authorization for Krause's Furniture to occupy the space. Please do not hesitate to call me if you would like to discuss this issue 'further. Otherwise, please indicate your confirmation of this statement by signing below and faxing this page back to my attention at (206) 575 -4140. Thank you for your help! Sincerely, TRAMMELL CROW COMPANY Jo Ann Bertram Property Manager City of Tu wila Crfirmatibn /11 /' Dat 17574 Southcenter Parkway Tukwila, Washington 98188 Office (206)- 575 -8090 Fax (206) -575 -4140 z 1 w JU UO co co cu J H co w w u_ = w F— _ z � ►—o z ►- w Lu U� o � w H IL. O ui z — = O ~ z OCT 30 '00 17:19 FR TRAMMELL CROW CO WW 1...0 tNSPCCTIQ NO. ( ITY OF TUKWILA SWLDING DIVISION 300 Southcenter Blvd, 0100, Tukwila, WA 98188 Addres l- _Type of Inspection: Date called: D wa �o ` 7 — ID -64 p.m. , ,. 'I0. V e lm 6 6:- 3960 -y�� z P I • \IJ• • --�. COMM ` nspect S. cwt,. Special instructions: 1 4 ... Approved per applicable codes. • $�17 NSPECT at 6300 Southcenter `receipt No: INSPECTION RECORD Retain a copy with permit d er jam 206 575 4140 TO 4313665 P.02/02 Pf,RMIT NO. (2061431 -3670 Corrections required prior to approval. Date. 7,n d') FEE REQUIRED. Prior to inspection, fee must be paid lvd., Suite 100. Call to schedule rein . - . ion. Date: ** TOTAL PAGE.001 ** ** TOTAL PAGE.02 ** 6-21-2200 I 0 : I 54.t.1 RECEIVED CITY OF TUKWILA JUN 2 2 2000 PERMIT CENTER 6/5/2000 Mitchell Contractors P.O. Box 167 24234 129 Ave. SW Vachon WA. 98070 Attention: Mr. Haven Stewart Subject: Parlo Supeh Dear Haven, FP.01 1 Th. 1 .e4:4.cr t. z' e ATP, En2:inecrilc 1 s provided by Mitchell Contractor. Inc Str s J.z . ,h-tts 4-ton ra...thar for Lnit to accoirirnoctattt the zietv . No :1oo1 s t.1 s:ld required. ara :he regarding th■s Sincerely, Arthur T. Rack P.E. Pi incipal ATR Engineering Inc. e i.:tt....;.:('•!.1; a :1 L;t■.,! ..ti ; DL lu. Li. arc': Into • - 0 . 1. additional frr...r. . ceilin8 and ii:sclati. as :;tiol.vri r r - • c SW 20(.0) CT hou WA. 98070 (20(5) -WI 5 /3.5 Lj no: :2606 ,nechanical SPIRES 6,105/ • tpad n/ ‘.k as le vt.L. w 4-Tort ....cd 6 '.O'!0 sis indicates that - act.:eplable sketch SK- k. plact'd untlei the ;:x:sting ' .,!Ae (Atif..)) when all introduce any electrical, 31.5 inch GLB are .1,:.:Id!;ons If you have any question Z Z tu•. .r 6m () 0: CO 0 '. (0 LW W I -J w 2 Li g Di i2 a. w: Z 0. Z wi 2 D. ° 0 LLI w: v rc5 z. wco z . 0 r 4.X P. 1 • 27 -2000 6 : 16AM FROM F+r'K -db 11: 41 4126/2000 z Mitchell Contractors 1 -0 - 2.0Oo H P.Q. Box 167 .- -- ,::. c _ _ � tt wt T -11 1- z 24234 129 Ave. SW .,, ...: t B ` 1, i Y • • ,.. _ . w Vashon WA. 98070 v v 0 Attentic+n: Mr. Ron Mitchell W W J V) u_ w 2 Dear Ron, I t . Please note that the existing glued - laminated beams are stressed in bending to their v S maximum capacity with an assumed additional load due to new bast insulation of 3 -1/2 p 1— inches thickness. In other words care must be taken not to introduce any additional dead w ur loads onto the framing system other than the new mechanical and the additional bait insulation u 0 w U =` o I z Subisct� Parkway Supercenter / Krause Furniture New mechanical units 1 have reviewed the existing structural system and the impact new mechanical units would have on it. My analysis indicates that 4ton mechanical units placed in alternate bins would be acceptable. (See sketch for unit location). Additional beams would have to be placed under the existing structure to accommodate the new mechanical units. If you have any question regarding this information please feel free to call. Sincerely. Arthur T. Rack P.E Principal ATR EnQineenina Inc. 9929 SW 206U1 CT Vadxa WA. 91010 (206) 463-573S 'D-2000 117 ! P.01 WON OD t3E'l' ttyyl APR 272000 PERMIT CENTER . -27 -2000 6: 1 6AM FROM P. 2 �►rt YM t�G -G10 11: V1 A EnglmstMg Inc. Consulting Engineer 9929 SW 206th Ct. Vahan. WA 96070 phone: (206) 483 -5735 A e'Gc - mare AN /[,QC.. 4 Tdb Data ihilZCav - .I PROJECT P i tirr Da I)1 P.02 Sheet No. Sk �� roTCE11ViD city OP TUKWIIA APR 2 7 2000 PERMIT CENTER ...,..._.., % z ry Z . Uo N CO W W O 2 gJ ' LL = ; H W Z I- F- 0 Z F- W 2 p ON O I- uj O Z. W = O ~ z DEPARTMENTS: Building Division hlAki -21-c0 Public orks `13 Complete Comments: WitROl11l.DOC NII StA PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D2000 -117 DATE: 4 -25 -2000 PROJECT NAME: KRAUSE'S FURNITURE SITE ADDRESS: 17740 SOUTHCENTER PY XX Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # - Revision # After Permit Is Issued APPROVALS OR CORRECTIONS: (ten days) CORRECTION DETERMINATION: qi o Fire Prevention AVG — l-- 0 v Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete TUES /THURS ROUT NG: Please Route Structural Review Required REVIEWER'S INITIALS: Approved n Approved with Conditions Approved I Approved with Conditions n REVIEWER'S INITIALS: Pla Division _2 j -o " Permit Coordinator DUE DATE: 4- 27-2000 Not Applicable n No further Review Required DATE: DUE DATE 5 -25 -2000 Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: DUE DATE Not Approved (attach comments) DATE: Fire Department Review Control ##D2000 -117 (510) Re: Krause's Furniture - 17740 Southcenter Parkway Dear Sir: City of Tukwila The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. The total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 3000 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 10B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (NFPA 10, 3 -1.1) Portable fire extinguishers shall be securely installed on the hanger or in the bracket supplied, placed in cabinets or wall recesses. The hanger or bracket shall be securely and properly anchored to the mounting surface in accordance with the manufacturer's instructions. The extinguisher shall be installed so that the top of the extinguisher is not more than 5 feet above the floor and the clearance between the bottom of the extinguisher and the floor shall not be less than 4 inches. Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206 -575 -4404 • Fax: 206 -575 -4439 Fire Department Thomas R Keefe, Fire Chief Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be identified with a sign stating, "Fire Extinguisher ", with an arrow pointing to the unit. (NFPA 10, 1 -6.3) (UFC Standard 10 -1) Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5) May 1, 2000 Steven M. Mullet, Mayor z Z ` ce W UO .0 Cow W =' N WO Q . U U = = Z � H Z F-. 0 p U 'O m ,. CI I-- w LLO w Z 2 O I' z City of Tukwila Page number 2 Steven M. Mullet, Mayor Fire Department Thomas P. Keefe, Fire Chief Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. (NFPA 10, 4 -3, 4 -4 and 4 -4.3) Every six years, dry chemical and halon type fire extinguishers shall be emptied and subjected to the applicable recharge procedures. (NFPA 10, 4 -4.1) If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 2. Exit hardware and marking shall meet the requirements of the Uniform Fire Code. (UFC 1207 -1212) When two or more exits from a story are required, exit signs shall be installed at the required exits and where otherwise necessary to clearly indicate the direction of egress. (UBC 1003.2.8.2) When two or more exits from a story are required and when two or more exits froma room or an area are required, exit signs shall be illuminated. (UBC 1003.2.8.4) All exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 1 1/2 hours in case of primary power loss, the exit signs shall also be connected to an emergency electrical system provided from storage batteries, unit equipment or an on site generator set, and the system shall be installed in accordance with the electrical code. (UBC 1003.2.8.5) Exits shall not pass through kitchens, storerooms, restrooms, closets or spaces used for similar purposes. (UBC 1004.2.2) Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206 -575 -4404 • Fax: 206 -575 -4439 : ry' Ax`• a5!' .M;'L1+.'7"+;Rm +rrrrt�mr;7;ry'F; ^s= '�eteT -_"fa .,,. �o-.,. �, yr�z—+ m,..,... µ.- � ..��,.....�- T....�.r.:w over,+ n maa: �- irw. xevnn... t � N' C` �! sCRMJa '.•,;*r5?efiC9E5'cY.Yht;7l7NA'k z re w �U U co o . w J I ' F- L WO � a 12 a I- Ili Z z �.. Z O U� uj }- IL I U H- 1 . IL .. Z : U O 1 ' z eirlsiva City of Tukwila Page number 3 All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1742) (UFC 1001.3) Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1742) 5. All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) An aisle to and working space shall be provided for n17 �4* 7t" �v ,4ts»XrA�x�q��. +;..a+nR.Xr'tt`* ... �i''""-.=..- w. e, �w ;.rwn3"• r�+nrr..7 .rzy«wrnurmfir•n.c Steven M. Mullet, Mayor Fire Department Thomas P Keefe, Fire Chief 3. Maintain sprinkler coverage per N.F.P.A. 13. Addition /relocation of walls, closets or partitions may require relocating and /or adding sprinkler heads. All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recognized by The City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1742) Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1742) 4. Maintain automatic fire detector coverage per N.F.P.A. 72. Addition /relocation of walls, closets or partitions may require relocating and /or adding automatic fire detectors. Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206 -575 -4404 • Fax: 206.575 -4439 Each circuit breaker shall be legibly marked to indicate it's purpose. (NEC 110 -22) 6. Your street address must be conspicuously posted on the building and shall be plainly visible and legible from the street. (UFC 901.4.4) 7. Accumulation of combustible waste material is prohibited during the demolition phase of this project. Remove and properly dispose of all waste material prior to the close of the working day and as often throughout the day as needed. Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Yours truly, City of Tukwila Fire Department Thomas P Keefe, Fire Chief Page number 4 each electrical panel. An aisle width not less than 24 inches shall provide access to the panel and 30 inches of working space shall be provided directly in front of the panel. (NEC 110- 16(a), NEC 110- 16(c)) • The Tukwila Fire Prevention Bureau cc: TFD file ncd S l 0 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206 -575 -4404 • Fax: 206-575-4439 Steven M. Mullet, Mayor z ~ • w 6 J o o co o: ww J • LL w 2 • a I a . F- _ z � I- O Z �. 2j U � 0 1- W W ' • U .z . 0 Y2 w t= O ~ z Kind of Fixture Fixture Units No. of Fixtures Total Fixture Units Public Private Public Private Bathtubs and /or shower 4 2 Dental units 1 1 Dishwasher 4 2 Drinking fountain (each head) 1 1 Hose bibb (interior) 5 3 Clotheswasher or laundry tub 4 2 Sink, bar or lavatory 2 1 Sink, clinic, flushing 10 10 Sink, kitchen 4 2 ( Z Sink, other 4 2 2, .- Sink wash, circle spray 4 4 Urinal, flush tank 3 3 Urinal, wall or stall 5 5 Water closet, tank 5 3 2. & Water closet, flush valve 10 6 Non -T • Sewer Use Certi ration (To be completed for all new sewer connections, reconnections or change of use of existing connections. C This form does not apply to repairs or replacements of existing sewer connections within five years of disconnect.) 411, Pursuant to King County Ordinance No. 11034, all sewer customers who establish a new service which uses metropolitan sewage facilities after February 1, 1990 shall be subject to a capacity charge. The amount of the charge is established annually by the King County Council but is limited by state law to $10.50 per month per residential customer or residential customer equivalent for a period of fifteen years. The purpose of the charge is to recover costs of providing sewage treatment capacity for new sewer customers. The charge is collected semi - annually. All future billings can be prepaid at a discounted amount. Questions regarding the capacity charge or this form should be referred to King County's Wastewater Treatment Division at (206) 684 -1740. (Please print or type) Owner's Name Property Tax ID # 3 - 76-r38 `-/ (Last, First, Middle Initial) Property Legal Address: Subdivision Name Lot # Subdiv. # Block # Property Street Address /7 7O Oct 7 m7 i . l'it"W y, L4I74 City, State, Zip Owner's Phone Number ( ) Owner's Mailing Address (if different from above) A. Fixture Units Fixture Units x Number of Fixtures = Total Fixture Units Total No. of Fixture Units _ 20 1058 (Rev. 2 /00) Total Fixture Units / 2- Residential Customer Equivalent (RCE) 20 fixture units equal 1.0 RCE . G RCE For King County use: Account # Monthly Rate Six Month Due Building Name (if applicable) I R A's e S 'Fowl-rug Party to be Billed (if different from owner) Party's Mailing Address: /1' cS ES •FranN t FLiZe Zoo N r a z1en y sr g 2S2 71- or Property Contact Phone # (I f ctO )- 571- f37 �7 City or Sewer District Date of Connection Side Sewer Permit # Demolition of pre - existing building? ❑ Yes ❑ No Demolition Permit # B. Other Wastewater Flow (in addition to Fixture Units identified in Section A) Type of Facility /Process: Date Estimated Wastewater Discharge: Gallons /days Residential Customer Equivalents (RCE): 187 gallon per day equals 1.0 RCE Total Discharge (gal /day) _ 187 C. Total Residential Customer Equivalents: (add A & B) A B • G RCE RCE I certify that the information given is correct. I understand that the capacity charge levied will be based on this information and any deviation will require resubmission of corrected data for determ' - 'on of a revised capacity charge. t Signature of Owner/ Representative Print Name of Owner/ .11 O I< Ill(,+ Representativ 4 71 4° White - King County Yellow - Local Sewer Agency Pink - Sewer Customer pi g,, •e` onwmii averixitriveciimmilivoirr,"" btu+i ". t[?11xtn'F" re,?11>P.'+tenif% !t�.±sti.'w .: .+a +,n,,•Irv.+c�•.?ce'�s sn :. rn . ; k.,•raw w ,..,m �r�rxsr.•m{sx•.,o•yr. 3rx..x. ., „Yer� rues. q:, �qr rrryve�e.r,++,ureuuiiwo?ciwit+ ?w mfltomoromilft z T- 6 � U 00 rn C LU J 1.— U) WO g rn l w z � H z W W 0 O - � u j F- H ti O w z U O I— z 7 -13 -1999 12:09PM FROM STATE OF • WAS IGTON MITCHELL CONTRACTORS, INC. 19505 VASHON HWY SW PO BOX 167 VASHON WA 96070 MASTER LICENSE SERVICE REGISTRATIONS AND LICENSES ORGANIZATION TYPE DOMESTIC PROFIT CORPORATION DOMESTIC PROFIT CORPORATION RENEWED BY AUTHORITY OF SECRETARY OF STATE - The above enlily has been issued the bua'riess reglsaadons or Iioenses Ustad DEPARTMENT OP LICENSING. BUSINESS & PROVFSSIONS OMSION. P.O. BOX am d. ruptA eI607.054 (350) MASS ) UNIFIED BUSINESS ID 1: 601 704 034 BUSINESS ID #: 001 EXPIRES : 04 -30 -2000 d licorwu+g F6=4.32.400 (07) DEPARTMENT OF LABOR AND INDUSTRIES REGISTERED AS PROVIDED BY LAW AS CONST CONT GENERAL. 04010 " To MITCHELL CONTRACTORS INC PO BOX 167 VASHON WA 98070 z ~ W �U U 0 WI CO IL. F— W0 g .73 _ ° . W 1- 0 z I— w 2 o. U 0 — 0 I - I U '. I- — LL 0 W z U( _ 0 z ACCEPTANCE SIGNATURES PHIL HAWLEY CHARLES SHELTON ���oFV.01 RUSSELL FRESE P� , 0 7000 CHARLIE HARRINGTON .\ ns\(o t D\ SHA 0 HERB FREIDMAN CYLE FRUTCHEY TOM BEALE , ALUM. A.C. ACOUS. I ADJ. AP. A.F.F. APPD. APPROX. ARCH. AVE. A.B. ABV. BLDG. BLKG. BD. BETW. BEV. B.F. BSMT. B.S. BLK. B.M. B.B. ATM. B.O.S. BM. CAB. CALC. CAP. CAT. C.BD. C.B. C.toC. CEM. CER. CHAM. CHAN_ C.L CHG. C.I. CIR. C.J. C.L. CLG_ CIKG. CLR. CLO. CO. CO. COL C.O. COMPO. CONC. CONC.BLK. COND. CONN. CONST. CONT. CONTR. CORR. CSK. CTR. C.J. C.R. DIM. DO. DIA D.F. Aluminum Asphaltic Concrete Acoustic Adjustable Access Panel Above Fin. Flr. Approved Approximate Architecture or Architectural Avenue Anchor Bolt Above Building Blocking Board Between Bevel Both - Faces Basement Both Sides Block Bench Mark Bottom of Beam Bottom Bottom of Steel Beam Cabinet Calculation Capacity Catalogue Chalk Board Catch Basin Center to Center Cement Ceramic Chamfer Channel Chain Link Change Cast Iron Circle Construction Joint Center Line Ceiling Caulking Clear Closet Cleanout Company Column Concrete Opening Composition Concrete Concrete Block Condition Connect Construction Continuation or Continuous Contractor Corrugated Countersink Center Ceiling Joint Crushed Rock Dimension Ditto Diameter Drinking Fountain DR. DWG. D.S. D W. DWR. E.W.C. E.G. EA. E.D.F. ELEC. ELEV. ENGR. ENGRG. ENTR. EQ. EQUIP. EQUIV. EST. E.P. EX.PL. EXC. EXP. EXT. EXTR. F.O.S. F.D. FON. F.OR. F.E. F.B. F.G. FIN. FLR. FLRG. FLUOR. FRPF. F.L. FLSHG. FT. FT. FTC.. FURN. F.J. F.O.M. F.O.W. F.F. F.S. F.G. GA. GALV. GENL. G.I. GLS. GYP. AD. GOVT. GRD. GR. GRND. GYP. G.L.B. H.B. HDW. HGT. H.M. HORIZ. H.P. HTG. HDWD. Door Drawing Downspout Dumbwaiter Drawer Electric Water Cooler Existing. Grade Each Electrical Drinking Fountain Electric Elevation Engineer Engineering Entrance Equal Equipment Equivalent Estimate Electrical Panel Exterior Plaster Excavate Expansion Exterior Exterior Face of Stud Floor Drain Foundation Fire Door Fire Extinguisher Fiber Board Finish Grade Finish Floor Flooring Fluorescent Fireproof Flow Line Flashing Feet Foot Footing Furnish Floor Joist Face of Masonry Face of Wall Finish Floor Finish Surface Finish Grade Gage or Gauge Galvanize General Galvanized Iron Glass Gypsum Board Government Grade Grille Ground Gypsum Glu Lam Beam Hose Bibb Hardware Height Hollow Metal Horizontal High Point Heating. Hard Wood HR. HDCP. D. N. NCL. NFO. NS. NSTU. NT. NV. NL. JST. JNT. LAM, LAN/. LBR. LNDG. L.P. LNG. L.H. LINO.. LINTL. LGT, LGTG. L.W.C. LOT.FIXT. MAS. MACH. MAINT. MATL. MAX. M.C. MECH. MTL. MEZZ. MFR. - MIN. MISC. MIR. MTD. M.O. M.B. MED. N.G. N. Hour Handicapped nside Diameter nch nclude or Inclusive nformation nsulate nstall nterior nvert nlet Joist Joint Laminate: Lavatory Lumber Landing Low Point Long Left Hand Linolium Lintel Light Lighting Light Weight Concrete Light Fixture Masonry Machine Maintenance Material - Maximum Medicine Cabinet Mechanical Metal. Mezzanine Manufacture Minimum Miscellaneous Mirror Mounted Masonry Opening Machine Bolt Medium Natural Grade North No. Number NOM. Nominal N.T.S: Not to Scale N.I.C. Not in Contract OBS. Obscure O.C. On. center OFF. Office OPNG. Opening OPP. Opposite ORIG. Original O.H. Over Head 0/ Over P.A. Public Address PART. Partition PERM. Permanent PL Plate PLAS.- - Plaster PLMBG. Plumbing PORT. Portable PR. Pair PREFAB. Prefabricated PRELIM. Preliminary PROJ. Project PLYWD. Plywood PLAS.LAA PT. P.P. P.O.C. P.T.D.F. QUAL. R.W. RAD. R. RD. R.D. RND. REF. REM. READ. REV. RF, REG. RGH. RM, REF. R.J. RTD. SIM. SCHED. SPL.BLK. SCHEM. SECT. SERV. SHT. SHTG. SNK. SPEC. SQ. S.S. SCRN. ST. STD. STL. STRUC. SUSP. SYM. SW. S.C. T.O.F. T. T.O.C. TELE. TEMP. T.O.G. T &G THRU. T.O.M. T.O.S. TYP. T.O.B. T.O.L. T.O.S. T.O.W. T &B U.N.O. VERT. VEST. W/ WC. WD. W.H. W/O Plastic Laminate Point Power Pole Point of Connection Pressure Treated Douglass Fir Quality Redwood Radius Riser Road Roof Drain Round Refrigerator Remove Required Revise Roof Roofing Rough Room Reference Roof Joist Rated Similar Schedule Splash Block Schematic Section Service Sheet Sheathing Sink Specification Square Stainless Steel Screen Street Standard Steel Structural Suspend Symetrical Switch Sow Cut Top of Footing Tread Top of Concrete Telephone Tempered Top of Grate Tongue and Groove Through Top of Masonry Top of Sheathing Typical Top of Beom Top of Ledger Top of Steel Top of Wall Top and Bottom Unless Noted Otherwise Vertical Vestibule With Wetercloset Wood Water Heater Without Detail Reference Building Section Reference Wall Section Reference Elevation Reference Room Reference Structural Grid Openings Revision Delta Finish Indication Earth Pavement Concrete Masonry Steel Plywood Wood Property Lines AA �- Detail Number Sheet Number Section Letter �- Direction of View -Sheet Number 3 112 I( Room Number O t z\t L9 Finish Number Direction of View Section Number Sheet Number Elevation Designation g- Direction of View Sheet Number (- Grid Number or Letter n section) Door Designation Window Designation Revision Designation Pavement Agg. Base Concrete (where applies) Sand Base (where applies) Agg. Base Masonry Units Continuous Interrupted tGLIJ Side View Vicinity Map NO SCALE OWNER'S REPRESENTATIVE KRAUSE'S 200 NORTH BERRY STREET BREA, CA 92821 Mr. CHARLES SHELTON DIRECTOR OF CONSTRUCTION (714) 990 -3100 (714) 990 -3561 FAX BUILDING CODE: OCCUPANCY GROUP: CONSTRUCTION TYPE: SCOPE OF WORK: 1997 U.B.C. TYPE V - N (FULLY SPRINKLERED) 10,030 S.F. INTERIOR TENANT IMPROVEMENT FOR A NEW FURNITURE SHOWROOM. A -1 A -2 A -3 A -4 A -6 ARCHITECTURAL TITLE SHEET, VICINITY MAP, & PROJECT SUMMARY EXISTING FLOOR PLAN SHOWING REMODEL WORK NEW REFLECTED CEILING PLAN FURNITURE LAYOUT PLAN A -5 FINISH / DOOR SCHEDULES DETAILS A -7 RESTROOM ENLARGEMENTS / DETAILS A -8 ENLARGED SALES COUNTER / DETAILS approva . Plan Check are e I understand that the sslon` and approval of u b l ecttoer rorsandom the violation of an. • / O' I ENTER -ARC INCORPORATED 950 South Coast Drive Suite Number 100 Costa Mesa, CA. 92626 tel. 714.427.0370 fax. 714. 427. 0375 I Sheet 0 Z w 0 TITLE PAGE Project No. 2864 Date 4/10/00 B.D. Submittal Bid Issue Const. issue Revision Revision Revision a 4O E TL7m , LEE 2 5 (MD PERMIT CENTER A -1 Dz000- 30 CENTER FLOOR DISPLAY WALL SECTION TYP. SCALE :. 1/8 V-0" EX STING HANDICAP PARKING. STALLS j KEY NOTE LEGEND El NEW 16" DIA. SONOTUBE COLUMN WRAP AROUND EXISTING COLUMNS. TYP. FULL HEIGHT TO CEILING, SEE O2 PAINT THE HEADER ABOVE THE WINDOW g3 NEW QUAD OUTLET LOCATED 7' -6" A.F.F. MOUNTED IN WALL ABOVE THE DOOR FRAME 4❑ EXISTING DOWNSPOUT ❑5 REMOVE THE EXISTING NON- STRUCTURAL POSTS © REMOVE EXISTING SALES COUNTER. RE -USE IF POSSIBLE ® NEW SALES OFFICE. 7❑ DEMOLISH EXISTING WALLS. ® EXISTING COLUMN TO REMAIN. NOTES: 1. THE EXITING LEASE SPACE IS FULLY SPRINKLERED. CONTRACTOR SHALL RETROFIT EXISTING FIRE SPRINKLER LINES SO THAT THE DROPS EXTEND DOWN TO THE NEW LEASE SPACE CEILING. THE WORK SHALL BE DONE UNDER A SEPARATE PERMIT. 2. PROVIDE 3/4" RADIUS BULLNOSE EDGE ON ALL PARTITION WALLS. INCLUDING TOP EDGES OF NON FULL HEIGHT WALLS. 3. PROVIDE A DURABLE SIGN AT EACH EXIT DOOR STATING THAT "THIS DOOR TO REMAIN UNLOCKED WHENEVER THE BUILDING IS OCCUPIED ", UBC 1004.37. Qa0 1DM 'Buff TYPB- INSHLU ITS 12ootF F MEL Sy57 - 6 1 To PACE Tn S"T'YLU- CTU.ve3 - - FEN.E2S • 2 -13 T 4 P 1 CUt L— W \TH V(WYL LEGEND 0 KEY NOTE REFERENCE O REFER TO A -5 FOR LEGEND INDICATES FINISH SPECIFICATION . . = = = = EXISTING WALLS TO BE DEMOLISHED. TYP. NORTH EXISTING WALLS ON EXTERIOR SHELL TO REMAIN. REPLACE EXISTING BASE WITH NEW BASE ( Bt ) TYP. NEW WALLS COMPRISED OF 3 -5/8" 25 GA METAL STUDS 16 O.C. WITH 5/8" GYP. BD. BOTH SIDES. GYP. BD. SHALL BE TEXTURED WITH A LIGHT ORANGE PEEL FINISH AND THEN PANTED TYP. UNLESS NOTED OTHERWISED. PROVIDE NEW BASE ei.. TYP. SEE ALSO NOTE: ALL NON -FULL HEIGHT PARTITION WALLS SHALL BE ATTACHED TO CONCRETE FLOOR WITH. 1/4 DIA. SHOTPINS 1' -0" O.C. (STAGGERED) AS ILLUSTRATED BELOW FOR STABILITY. ENTER -ARC 950 South Coast Drive Suite Number 100 Costa Mesa, CA. 92626 tel. 714.427.0370 fax. 714. 427. 0375 • INCORPORATED Sheet N N D EXISTING FLOOR PLAN SHOWING REMODEL WORK Project No. 2864" Date 4/10/00 B.D. Submittal Bid Issue CITY OFEN' Const. Issue APR 2 5 20W Revision PERMIT CENTER Revision Revision A -2 NEW SUSPENDED. ACOUSTICAL CEILING AT. 12'. -0" A.F.F.- II . 1111111 1111111111111Mliant 1 ti �'\ 1 I �4 31111111111111111111111 Mk - - -- - :'1 i'� `,1 .fit °s�L�� WNW= 11 IKV11111011=11111111111' Kol 11: 2111 Mt WiriinillaMMIK III II mix mitc* 312111111111B1111111111110 Migtagfnegil ■VPIJIVIIIIr ME BiliWaiRMEMOWONIIM 1116M1111 ime:miciawalEMPA11111111m11111111111 1111 W \_ Ma 111111111113111.1111111===111111 MI SEW WM ER owl 1121R12 EMS WM 111111111151111111111111111111111 all 1111111111111102E SIMI -- i 1111‘1111111=111111MMINNIMENIIVIIIIISSMIMINWMIIMM IS Mill= == NM IIIPM1115111111111111111 MI 1 111AN_IMME1111Wit II =- -- MIME® ® 1 111117631111111111111 I I ®1 1 / I 111111311111111 OE 1111115 111112131111111111111 CI IFOINVIIIIM11111/ i ®1 1.1 I �1 . t ■ 11 PI O ® �� raWalli ®1 ®® �i i . ll ___I_ 1 : I MINNM Mil MIME ® I ®�® I� ism ® ma r�� ®im 1;1l . - e' I °®tom ® ®i H - >/ d a i Is I \ i . NM ,, \\ I �: I , ® �: o 'I� I , . 1 ' ' . i ° I \� v`FO1� ® ®�� _________ _____ ...,--- - NM 11N1 I 1111111MINNIO IN M111111111111111111 1 ism �— I �t ®fie.. Iiii ii I, \ 1 : d {� I 1. 11131111011111 I , ®NE �> .011111111N M 1 ; MISIBEIIII 11 RN 11•1111IFYI IMIlitiVAIMIleilk1111111111111 ,..,: MEN MN larnaf24111111WIRMIN BILE 11111M111111111 I BM 111,1111 NEW GYP. BD. CLG. 8' -0" A.F.F. (PAINTED) NEW WALLS KEY NOTE LEGEND EXISTING WALLS., ® NEW 2' x 4' FLOURESCENT FIXTURES. Q NEW 1' x 4' FLOURESCENT FIXTURES. 7t NEW 4' TRACK LIGHTING: •L p . LL a NEW - 8' . TRACK UGHTING. ® AIR RETURN. I EXIT I ILLUMINATED EXIT. SIGN CEILING MOUNTED DOOR SENSOR 6' BACK FROM THE ENTRANCE. SENSOR SHALL CONNECT TO A BELL LOCATED IN THE BREAKROOM. NORTH ENTER -ARC INCORPORATED NEW REFLECTED CEILING PLAN Sheet 950 South Coast Drive Suite Number 100 Costa Mesa, CA. 92626 tel. 714.427.0370 fax. 714.427.0375 Project No. 2864 Date 4/10/00 B.D. Submittal Bid Issue RECEED Const. Issue CITY OF TL T " Revision APR 2 5 2000 Revision PERMIT CENTER Revision A -3 i�seeea a ® eltlfeeet�lp■ ■gee see/ '®®®irjjrioreoen linumumernonumerminnu t a■ eaeemeseel eeeeeee■ee/ /seerleem e i I®4aef ®eeeeilsef a� ®Y� IIA /�! /e ��w ® 8eel E /� ® ® ®lee5y //39 /ll.��._�_�_ ®ee► eese/�eeeL• /� ®® ' eleel . l iia mirE =eeec !_1158111 ®J Ir m■ ■I ■ ■■ ■.■ ■ ® m, sm ammm mi eeeeeeee lileee l eeeeeeee/ /eeelu�i . ® ■ ■■. ■ ■ ■..■.. ■. eeeeeaee® seeei/eea ® ®e/1/ ee.e las b /seal/ ®arena me / �I L E G E N D EXISTING WALLS TO - REMAIN = NEW WALLS = = = = WALLS TO BE DEMOLISHED O WALL OUTLETS o EXISTING FLOOR OUTLETS >.. QUAD, OUTLETS D TELEPHONE D TELEPHONE -/ DATA (E) EXISTING. NORTH ( N) N EW I l 8' - X 10' FURNITURE ARRANGEMENT (BY OWNER) I ENTER-ARC INCORPORATED 950 South Coast Drive Suite Number 100 Costa Mesa, CA. 92626 tel. 714.427.0370 fax. 714.427.0375 O %VS co W 0 O .„0 Q a oc W FURNITURE LAYOUT oe z z U x O 0 Project 14o. 2864 Date 4/10/00 B.D. Submittal Bid Issue ) RECEi w Const. Issue CRY OF "' A Revision APR 2 5 2000 Revision PERMIT CENTER Revision DOOR SCHEDULE CEILING FINISH SCHEDULE FLOOR FINISH SCHEDULE NO TYPE ' SIZE RATED MATERIAL FINISH FRAME THRESHHOLD HARDWARE ACOUSTICAL . CEILING SYSTEM SCHEDULE CARPET CONTACT: DANIEL SALERNO (714) 536 -3907 NO MANUFACTURER SPECIFICATION COLOR INSTALLATION LOCATION NO MANUFACTURER SPECIFICATION COLOR INSTALLATION LOCATION WIDTH HEIGHT THICKNESS * 1 , CAE, - .'A _ 3 ' -0 ' PAIR 7 1 -1/4" _- STOREFRONT ODOR CLEAR. ALUMINUM ALUMINUM ' — .. #1 - 1 , -2 - _—... I. ARMSTRONG WORLD INDUSTRIES ARMSTRONG WORLD INDUSTRIES -. - "CORTEGA #735, 2'x4'x5/8' CLASS A FLAME SPEED, SQUARE LAY IN -. 2" X 4' 5/16" EXPOSED TEE GRID W/ LOW WALL MOULDING. "WHITE" OR PAINTED P -3 "WHITE" OR ' PAINTED P -3 INCLUDING OFFICE, PANTRY AND REST ROOMS INCLUDING OFFICE, PANTRY AND REST ROOMS CPT LOTUS CARPETS COLUMBUS MILLS,I STYLE: /� L. L" 240376. FORMULA: DR 20884 'ONCORE', 24 OZ. GREY /MAUVE SPECIFIED - - `�' THROUGHOUT SHOWROOM INCLUDING RAISED PLATFORMS, EXCEPT AS NOTED. 02 C 3' -0" 7' -0 1 -3/4" _ SOLID CORE DOOR - PAINTED TIMELY — #2 VINYL COMPOSITION TILE CONTACT: KARNDEAN REP. TONY GOLBURN (760) 967 9544 O. C 3' - O" 7' -0 1 -3/4' — SOLID CORE DOOR PAINTED ;..; TIMELY •, y # i- NO MANUFACTURER SPECIFICATION COLOR INSTALLATION LOCATION O *n �� ll B B 3• - 0" 3 -0" 7' - 0" 7 -0° 1 - 3/4" 1 -3/4° - SOLID CORE SOUD DOOR CORE PAINTED PAINTED* TIMELY TIMELY - #z #1 LIGHTING SYSTEM SCHEDULE VT1 "KARNDEAN" NORTH AMERICA TILE COLLECTION KOMBINATION" 12 "X12" LUXURY VINYL TILE, J -89 "MERCURY" AT ENTRANCES AND IN FRONT OF ORDER COUNTER (TURN EACH ALTERNATING TILE 90', TYP.) NO MANUFACTURER SPECIFICATION COLOR INSTALLATION LOCATION * CI E: D B' —o" 7 -6" t" — DOOR !AINTED.. , _ Ll O NORA LIGHTING INC. NTH -109 Ft/PAR-38 HEAD NT -302 WHITE 4Fi TRACK. - NT -304 WHITE 8 FT TRACK t NT 312 WHITE 12 FT TRACK NT -311 WHITE LIVE END FEED NT -332 WHITE BAR ATTACHMENT CLIP "WHITE" PER PLAN C2 ARMSTRONG 'STONETEX' "EXCELON" 12 "X12" LUXURY VINYL TILE, 52121 IN REST ROOMS, OFFICE AND BEHIND ORDER COUNTER B 3' -0" 7' -0" 1-3/4- / _ SOLID CORE DOOR PAINTED.. TIMELY _ - #1 t 4 —0" r-0- 1 -3/4° - SOLID CORE DOOR PAINTED TIMELY — #2 VT3 "KARNDEAN" NORTH AMERICA TILE COLLECTION "DA VINCI" 12 "X12" LUXURY VINYL TILE, CS - 75 LEAD ALTERNATE VINYL TILE AT ENTRANCES AND IN FRONT OF ORDER COUNTER (TURN EACH ALTERNATING TILE 90 TYP.) • �E , ' 3 -0" PAIR. 7• -0" 1 -1/4" — STOREFRONT DOOR CLEAR ALUMINUM ALUMINUM a — — 1 -3/4 _ DOOR;: CORE PAINTED•* TIMELY — # . 'L3 COOPER LIGHTING INC. FLOURESCENT LIGHTING. FIXTURE 'METALUX' #2G332A, 120V, EBB1, 3 —T8 LAMP STANDARD, 2 X 4 LAY —IN FIXTURE "WHITE" PER PLAN NOTE: RESTROOMS ARE REQUIRED TO BE ACCESSIBLE TO THE PUBLIC AND THE FLOOR FINISH MUST COMPLY WITH UBC 807.1.1. REMARKS: _ _ •. EXISTING •• INTERIOR -SEE A -2; EXTERIOR TO MATCH EXISTING EXTERIOR' - .L4 COOPER LIGHTING INC. RECESSED CAN DOWN LIGHT - 'HALO' #H7854T/6870P SEMI — RECESSED ADJUSTABLE ACCENT LIGHT "WHITE" PER PLAN i NOTE: ' ALL NEW DOORS SHALL BE EQUIPPED WITH. LEVER TYPE HARDWARE HIGH PRESSURE LAMINATED PLANK CONTACT: KARNDEAN REP. TONY GOLBURN (760) 967 9544 NO MANUFACTURER SPECIFICATION COLOR INSTALLATION LOCATION . HARDWARE SCHEDULE: HARDWARE GROUP 91 HARDWARE GROUP 92 HARDWARE GROUP 93 L5 PHILLIPS TRACK LIGHTS LAMP PHILLIPS #60 AR/ SP 12, 60 WATT. PAR 38 LAMP W/ 12 DEGREE SPOT, 1110 LUMEN OUTPUT 2700K PER PLAN "KARNDEAN" NORTH AMERICA WOOD PLANK COLLECTION "DA VINCI" 3" x 36" LUXURY VINYL TILE, SQ, EDGE RP01 "NORWEGIAN SPRUCE" DESIGN CENTER IN CENTER OF SHOWROOM _. ;. PROVIDE CLEAR, ADA ADA APPROVED • LEVER LEVER HARDWARE, APPROVED LEVER HARDWARE, LOCKSET AND . LOCKSET CLOSER AND - HARDWARE, LOCKSET CLOSER. . 12" KICK PLATE. _ - WEATHER SEALS AND - - ASTRAGAL. : - L6 GENERAL ELECTRIC INC. - FLOURESCENT LAMPS #F32T8/ SPX30, 32 WATT T -8 LAMP W/ RE 830 PHOSPHOR 3000K PER PLAN BASE COVE L7 O GENERAL ELECTRIC INC. .: - RECESSED CAN DOWN LAMPS, #FLE20TBX /R40 /EC 20 WATT, TRIPLE BIAX, COMPACT FLOURESCENT LAMP W /R40. REFLECTOR & RE 827 PHOSPHOR 2700K PER PLAN NO MANUFACTURER SPECIFICATION COLOR INSTALLATION LOCATION DOOR TYPES: B 1 BURKE FLOORING PRODUCTS TOP SET BASE 4" HIGH RUBBER COVED. NO. 564 —P "SMOKE" ON ALL VINYL FLOOR EDGES C ". WALL PARTITIONS ON CARPETED AREAS 4 1/4" X 1 -1/4" - INTE INTERNATIONAL ALUMINUM FRAME SYMBOL OF LH GENERAL ELECTRIC , INC. FLOURESCENT LAMP BALLAST #GL— RL— T8 -11L -120 RAPID START, LO —WATT, LOW LIGHT ELECTRONIC BALLAST PER PLAN _ T - O O* I O EXISTING STORE — 0 FRONT DOORS -.. < ACCESSIBILITY B BURKE FLOORING PRODUCTS TOP SET BASE 2 1/2" HIGH RUBBER COVED. NO. 564 —P "SMOKE" ON DESIGN CENTER PLANK FLOOR AREA SOLID CORE DOOR. : SOLID CORE DOOR 12" KICK PLATE L9 COOPER LIGHTING INC. 'METALUX' #12 PATTERN 100% ARCYLIC : 1 -1/2" X.1 -1/2" PARABOLIC LENS ADJUSTABLE ACCENT LIGHT CLEAR PER. PLAN - C TEMPERED GLASS - 0 © O ® JOHNSON FLOORING TRANSITION STRIPS, EDGES GUARDS NO. CTA -42 —C NO. CTA -42 —A NO. EG -42 —H AT WOOD VINYL FLOORS AT VINYL FLOORS AT BARE FLOORS *p 00 OVIUL,, WALL FINISH SCHEDULE A ppROV E May I° '1..00 NO MANUFACTURER SPECIFICATION COLOR INSTALLATION LOCATION CARLON ELECTRICAL PRODUCTS. : #E971FB ROUND FLOOR BOX #E97DSC DESIGNERS SERIES FLOOR BOX COVER "CARMEL" PER POWER PLAN EXISTING - SECTION - INTERIOR PAINT SCHEDULE - " „ S ,ON - LEVITON - ELECTRICAL WALL PLATES (DUPLEX AND FOURPLEX WALL OUTLET. MINIMUM HEIGHT 15" A.F.F. PER CODE "IVORY” PER POWER PLAN - NO MANUFACTURER MANUFACTURER NO. COLOR _- FINISH BLII . - Q - (D SHERWIN WILLIAMS SW1053 "LIGHT MOVES" FLAT, "ORANGE —PEEL FINISH" ® ERICO FASTENING PRODUCTS TELEPHONE WALL JACKS #MP 1 MOUNTING BRACKET, SINGLE GANG W/ PLATE .. "IVORY" PER POWER PLAN P2 SHERWIN WILLIAMS SW1080 "MERINO WOOL" FLAT, "ORANGE —PEEL FINISH" -� - - .. - -- - - - - - " = ' DOOR SCHEDULE CD SHERWIN WILLIAMS SW1109 "ARIA IVORY" FLAT, 'ORANGE —PEEL FINISH" DOOR SYSTEM SCHEDULE P4 SHERWIN WILLIAMS SW1313 "RUSTIQUE" FLAT, "ORANGE —PEEL FINISH" NO MANUFACTURER SPECIFICATION COLOR INSTALLATION LOCATION 01 PAINT GRADE SOLID CORE, PAINT GRADE DOORSJA WITH TIMELY METAL P 2, DOOR JAMBS - E ROOMS , OFFICES RESTROOMS, STORAGE AND BREAKROOMS AS SHOWN ON PLANS. P ) SHERWIN WILLIAMS SW1455 "FORMAL GARDEN" FLAT, "ORANGE —PEEL FINISH" ® THE STANLEY WORKS 3 -4 1/4 BUTTS #626 SATI CHROME ALL DOORS - - P6 SHERWIN WILLIAMS SW1614 - "DUCHESS ROSE" FLAT, "ORANGE —PEEL FINISH" _ SCHLAGE , 'A' SERIES PASSAGE AND LOCK SETS W/ LEVON LEVER HANDLES . 11 -085 SQUARE CORNER DEADLATCHES. #626 SATIN CHROME - ALL DOORS CD SHERWIN WILLIAMS SW1609 "RENOIR RED" FLAT. "ORANGE —PEEL FINISH" ( DS1 NEWMAN TONKS QUALITY HARDWARE NO. 331 ES:- DOOR STOP, (1) 1/4 -2021" MACHINE SCREW - AND EXPANSION SHIELD. SATIN - CHROME - ALL DOORS - P$ SHERWIN WILLIAMS SW) 649 "MELON BALL" FLAT, "ORANGE —PEEL FINISH" MISCELLANEOUS SCHEDULES Ps SHERWIN WILLIAMS SW1545 'VIBRANT VIOLET" FLAT, "ORANGE —PEEL FINISH" MISCELLANEOUS FINISH SCHEDULE SHERWIN WILLIAMS SW)097 - "YORKSHIRE BROWN" FLAT, "ORANGE —PEEL FINISH" NO MANUFACTURER SPECIFICATION` - -- COLOR INSTALLATION LOCATION O SONOTUBE - 12 " -20" DIA:,_DENSE CARDBOARD _ TUBES, TAPED, MUDDED, FINISHED AND PAINTED P -2 FLOOR TO CEILING ... '.. SEE FLOOR PLAN FOR SIZE. . PAINTED 'P2' FLOOR FINISH AT TOP OF SALES COUNTER AND - CENTER CONSOLE - - SHERWIN WILLIAMS SW 1433 "CHIVES" FLAT, "ORANGE —PEEL FINISH" '® SHERWIN WILLIAMS SW2839 (EXTERIOR) - "ROYCROFT COPPER RED" FLAT, "ORANGE —PEEL FINISH" (P13) SHERWIN WILLIAMS SW1370 "PROVINCIAL GOLD" FLAT, "ORANGE - PEEL FINISH" PLASTIC LAMINATE FINISH SCHEDULE ^�^ � NO MANUFACTURER SPECIFICATION COLOR INSTALLATION LOCATION MD SHERWIN WILLIAMS SW1754* "TIDE POOL" FLAT, "ORANGE —PEEL FINISH" WILSONART NO. 4624 -60 - PLASTIC LAMINATE "BEGE— NEBULA" AT TOP OF SALES COUNTER AND CENTER CONSOLE INCLUDING EDGES. SHERWIN WILLIAMS SW11 13 - ; "RAFFIA VASCEK" FLAT, "ORANGE —PEEL FINISH" WILSONART NO 0433 -60 "VICUNA" AT FACES OF SALES COUNTER AND CENTER CONSOLE * VERIFY WITH RUSSELL FRESE (714) 990-3100 ext. 5022 PM INCORPORATED 950 South Coast Drive Suite Number 100 Costa Mesa, CA. 92626 tel. 714.427.0370 fax. 714.427.0375 o.) w vi „mom. „zo 41 4 ,.., v E O lig v Revision Revision Sheet 0 Z 0 h Q FINISH SCHEDULES DOOR SCHEDULE Project No. 2864 Dote 4/10/00 B.O. Submittal Bid Issue RECEIVE() CITY OF T "'��lLq Const. Issue APR 2 5 2001 Revision PERMIT CENTER A -5 p "�i > ' ' j �� / ✓ -�� / % / j / /' / %' / - RED PAIN ARCH � � J TEXTURED TED ANCHOR 3 5/8 x 20 GA. WOOD STRUDCTURAL EXISTING MEM MEMBERS " T TY W/ 4 1/4 LAG BOLTS, P. OF ROOF •L �I .;- . I . +HIGH ` 2� II, ROVIDE 2 1/2" AT THE CENTER WAbLS�:B2 PRESSURE 'Ll�MINg7L. RUBBER BASE FLOOR DISPLAY •--•, ! 1 _ _ — � Aim ! ! /! / / . / / // !� `// / y / UNDERSIDE 3 5/8" 20 GA. DIAGONAL ` ' �i /! „,/, / - " j- /% j , � I� ti Y /, / j < ! , ® ! x - RACE TO BRACE 3 5 /8 " 20 GA. PARTITION METAL STUDS TOP FRAMING W/ 4 - #8 SHEET METAL Q CD 80 DES ` g : ANCHCE TO PARTITION / ! // ' PROVIDE 2 1/2" RUBBER. BASE // a TOP C/ 4 //8 .'` - - \ �- / / ,/ '`/ % - /.. - G�, / '' �' / � / i i / - / \� W TE CENTER FLOOR DISPLAY H- / i / i i��i // �' � W � LS : / / . / J // / ! B2. v %' : / .` v '' ' / ' am ` / . / -� / /'- ''' ! -' - !� ! - / / / ! / / j /' -' �' / % /<, - / �> N OTE: PROVIDE 3/4" RADIUS T- / BULLNOSE / / _ -. AL L PARTI EDGES ON i i' / / i . �/ / .' / . ' / ... ! i ALL PARTITIONS. / i / �_ _ _� I - I I I III I ES.ANID 3'_ 3 5" 3' -0 - I III I f ° - ! 9R L" � _AND _. ! TOP ON .,.^ �i HEDULEED BY KRAUSE'S. ` - �µ. INSTALLED BY CONTRACTOR. / � : `" ! / `� `! // = � I III 1 III I I III I II I I III i I III III III L J_ III I a NOTE: PROVIDE BULLNOSE TOP ON I! I k III I 1 G III 1 III I 1 3/4" RADIUS EDGES AND ALL PARTITIONS. I I I III I I III I III I I I I III I 1 I II I II I G I I I I I 3 5/8" x 20 GA. METAL STUDS % & END FRAMES ® 16" O.C., ANCHOR BOTTOM TRACKS TO EXISTING CONCRETE FLOOR W/ "HILTI" X -ZF POWER DRIVEN FASTENERS ® 32" O.C. MIN. 1" EMBEDMENT. METAL STUDS- REP 17E5- P205S350 I.C.B.O FINISH FLOOR "Z WALL `PARTITION SCALE 1/4 " =1 -0" 12I PARTITION WALL ISOMETRIC . S C A SCALE 1 4 " = 1 • -0" / ,. I ° p SEE FOR - 1 \ S • � FLOOR PLAN DIMENSIONS _ - - �7YP. - NOTE: PROVIDE 3/4 BULLNOSE TOP ON ALL / - RADIUS EDGES AND PARTITIONS. l � i i i + �'' ,/ � ! � // ! ��/ ' ,- / i �� / / �, ��i % / A 7 ! !' / w �y/ / ! / . v �! v! /` ' ! / ,,� / /// y v % / ! ,- ' / . „ i � �� / ! / !� i /� ,/ �� --- / / „�� ; - ' �, / / ' , —' ! : - 0 v �„ HIGH PRESSURE '',/' I 1'NATE PLANK .: / DETAIL T SCH #1 BASE I I1 I /IIIi�I I / �C 1 .1 to a.- I \ 4 -O 4 / ! - f � / / / �` ... '- / �� - / / ! � ' /! i / � - // / -' % % i ! / !/ / --->„" / / i �! � / ' / " �' /�- - / ' ' !�/ / % FOR SCHEDULE) - PROVIDED BY KRAUSE'S / - INSTALLED BY .CONTRACTOR. PROVIDE 2 1/2" RUBBER �, 5 6 4' -91--6 4'- �/ / � ? / / � .- ' / -/ ! �' ' ,' ' / > % /� / ' / / v., % / .% 7 4 '' ! - i - AT THE CENTER FLOOR DISPLAY ' ! /' / / /`� / !� i - NOTE: PROVIDE 3/4" RADIUS // /� ' / /' BULLNOSE EDGES ON / ,� ..- ALL PARTITIONS. 5" •\ PLAN VIEW "T" WALL PARTITION SCALE 1 /4" =,• —O" 11 ARCHED WALL PARTITION ISOMETRIC SCALE 1/4 " =1' -a" 5 ARCH SUPPORT DETAIL SCALE 1/2 =1 -0" 1 2 I - - - - 1/2" THICK PLYWOOD - 0 El PARTITION PANEL POSTERS: PROVIDED BY KRAUSE'S I BY G.C. I�N�S- "QUALITY ASSURANCE" 1�1 "FABRIC TO FRAME" Q "PERSONAL STYLE" "CUSTOM CRAFTED QUALITY" ® r 8 11111=1■1117111111MENIM I "M LOCATION OF ELECTRICAL L. _ I- OUTLET (BEHIND DRAWERS). ®.�S�da�9E�':�� . �9�8�Qa KICK FILE -. r ° I „0 - ,8 „0 -.9 a i � ' i > / / / r / v ^�6' / ' ak.g. ' % ~ rte ARCH SUPPORT DETAIL PROVIDED BY KRAUSE'S INSTALLED BY CONTRACTOR. INSTA INSTALLED ED INSTALLED 2 vv >' ` ° � ' / / 113\SW NOTE SUBMIT BY CONTRACTOR. KRAUSE'S FOR PREFABRICATION. BY CONTR ® ,,,,/,/ / / /, , - , � �/ _� \ . �iT F ® �pY ' 0 la I� P1 \ISI� © © QJI° NOT USED 10 TYP. CNTR. EDGE SCALE 3 ° •1 • -0' 8 CTR CONSOLE ELEV. SCALE 1/2 " =1• -O" 4 0 I � ►�► ( 1; H�ORIZONT lipr 0 PROVIDE WOOD PLANK FLOORING UNDER CUTAWAY PLATFORM & CENTER CONSOLE. TYP. . - . ` - 5 -/2"w6 COLUMN. I © ° wrS • I17, / ,K ■ 1 -7 1 /4 "I 2'-3 1 -7 1 /4 , _ ,� � 3 c ® y � 1' EXISTING NEW TELEPHONE OUTLET. NEW TELEPHONE & DATA OUTLET. .. '// W PROVIDE ROUNDED CORNERS _ ® ALL GYP. BD. WALL CONDITIONS. SEE gk VP \.. ` tO \ .� . N 1 ,:. FI 0 \ � • 4. c ' •4W ■ , /// = as �.� , °- /. ' ��'G�// — I — . I 2 " GROMMET (COLOR 2 .COMPLIMENT PLASTIC .LAMINATE TOP). \ \ - 8 -0" - 1 _8'_0" 8' -0" - FILE FILE ( -: - - - - - — I NEW ELECTRIC OUTLET MOUNTED AS HIGH �AS POSSIBLE, CLEAR OF DRAWERS. - 3/4" CONDUIT STUB UPS FOR TELEPHONE, ELECTRIC &ONE, DATA. I , FILE I - E 24' 0`. PROVIDED INSTALLED , .. .. FOR SIDE VIEW Bil. KRAUSE'S BY`,CONTRACTOR. - 40' -D" 200c)pli \ __ f NOT U SED 1 NOT USED 7 CENTER 'CONSOLE SCALE 1/2 " =1' -0" 3 CENTER FLOOR DISPLAY AREA SCALE 1/e " =1; -O" ENTER -ARC INCORPORATED 950 South Coast Drive Suite Number 100 Costa Mesa, CA. 92626 tel. 714.427.0370 fax- 714.427.0375 m Z IIII 02 co cC CO 0 0' S» ' 0 z S Z Z O O z N >- Q • Q w o_ F w Z Z w w U U S r DETAILS 0 O ' Project No. 2864 Date 4/10/00 B.D. Submittal Bid Issue crrr DV ,,,, Const. Issue APR 2 5 ))IR Revision PERMIT CENTER Revision Revision Sheet A -6 (WALL ASSEMBLY PER 1CR0 1715) R -13 VINYL COATED) INSULATION WITH V OR BARRIER AT THE W•RM 0 S'AC . WALL PARTITION DETAIL ELUZED ROOF STRUCTURE / 2 X 4 JOISTS 0 24" O.C. (2) #8 S.M.S. EACH STUD. 3 5/8" METAL STUDS BRACES: ®4' -0" O.C. STAGGERED EACH WAY -R 19 ENCAPSULATED INSULATION W/ VAPOR BARRIER SET ON T - BAR CEILING, TYP.. . SUSPENDED ACOUSTICAL CEILING CONT. TOP TRACK 3 5/8" 25 GA METAL STUDS (ANGELES METAL STUDS OR EQUAL) '® 16" O.C. W/5/8" GYP. BD. BOTH SIDES (PAINTED) SECURE BOTTOM TRACK TO SLAB HILTI ON37P8 OR EQUAL SHOT PINS ® 24" O.C. (ICBO #2388) TOP SET RUBBER BASE -BOTH SIDES CONCRETE SLAB SCALE 1 1/2 " =1' =0" TYPICAL 12 GA. VERTICAL HANGER WIRE 0 12' -0" EA WAY W/ MIN. 3 TIGHT TURNS IN 1 -1/2' BOTH ENDS OF WIRE. 12 GA. BRACING WIRE ® 12' -0 ". EACH WAY W/ MIN 4 TIGHT TURNS IN 1 -1/2" BOTH ENDS OF WIRE, TYPICAL. 1 NOTE: SPLINE MAY START A i MAXIMUM OF 4' -0" FROM WALL. SEE SONOTUBE BACK FRONT FOR PAINT TERMINATIONS TYP. CORNER EDGE COLUMN COLLAR (ACCENT COLOR SIDE) SEE TEXTURED WITH A LIGHT ORANGE PEEL. FINISH AND PANTED. 5/8" THICK GYP. BD. 3/4" RADIUS METAL CORNER FILLER (TYP. ON CORNERS) 3 5/8 " -25 GA. METAL STUDS ® 16 " O.C. COLOR LINE TYP. SCALE 3 " =1' - 0 TOP OF SONOTUBE CEILING LINE 4" VINYL BASE GLUED TO TOP OF SONOTUBE PAINTED P2) • ACOUSTICAL CEILING I.C.B.O. #2244 MAIN RUNNER. SCALE 1/2 " =1' -0 NO SCALE REAR OF SHOWROOM FRONT OF SHOWROOM PLAN RESTROOM 4" RUBBER BASE GLUED 81, TO BOTTOM OF SONOTUBE FLOOR LINE. SCALE 3 " =1' -0" CREATE A SCORE LINE OPPOSITE THE LONGITUDINAL SLICE TO OPEN SONOTUBE AROUND COLUMN SONOTUBE (SLICED OPEN) FOR INSTALLATION SUGGESTED INSTAI LATION OPEN, TWIST AND TURN THE SONOTUBE COLUMN TO FIT. AROUND THE NEW BRACING COLUMN 2 x BRACING NAILED TO COLUMN (4 LOCATIONS MIN.) NOTE: SONOTUBES SHALL BE SEALED PRIOR TO APPLYING SKIN COATING & TEXTURED SPRAY. FOR COLUMN COLLARS TOP AND BOTTOM SONOTUBE 2 x VERTICAL NAILED 2.x BRACING ® 2' -0" O.C. NAILED TO COLUMN TEXTURE PAINT (P'T )TYP. CONVENIENCE OUTLETS 15" A.F.F. MIN. SCALE 1 • EXISTING COLUMN VERIFY SIZE. & SHAPE. - PAINT IF P2 EXPOSED NOTE: CUT SONOTUBE LATERALLY ON ONE SIDE ONLY. SPREAD EDGES TO ACCOMMODATE. COLUMN & WOOD ,• BRACING.. MUD, PATCH & PANT PZ SEE FLOOR PLAN FOR SIZES. • PLAN & ELEVATIONS - �._12- - ---- - -- - -% ELEVATION B Z� - - - ice - m L 28" MIN T CLEAR ELEVATION A WOMEN'S'. 32" 1 MIN. 1:14000-irl TOILET PAPER DISPENSER 48" MARLITE WAINSCOT ON ALL WET WALLS 1 1/2" DIA. GRAB BAR WITH 250# FORCE BOBRICK 3 -6806. 1 -1/2" SPACE BETWEEN WALL AND GRAB BAR. 4" VINYL BASE 2' 0" X 3 -O" MIRROR SOAP DISPENSER 1 -1/2" DIA. STAINLESS STEEL HANDICAPPED GRAB BAR BOBRICK B -6806. 1 -1/2" SPACE BETWEEN WALL AND GRAB BAR. INSULATE ACCESSIBLE HOT WATER AND DRAIN PIPES WI APPROVED BOOT. BRAILLE SIGNAGE C 60" A.F.F. NEW HINGED DOOR W /LEVER HARDWARE CLOSER, 12" KICK PLATE AND LOCKSET FOR PRIVACY EW TOILET PAPER DISPENSER NEW FLUSH CONTROL 44" MAX. ABOVE FLOOR AT WISE SIDE. FLUSH CONTROL FORCE Slb. MAX. \S \ C� 1 FAUCET CONTROL FORCE 51b. MAX. SELF CONTROL VALVE TO REMAIN OPEN 10 SEC. AN. KNEE CLEARANCE 30" WIDE, 48" DEEP TOE CLEARANCE 30° WIDE, 17' DEEP 9" HIGH MIN. BRAILLE SIGNAGE B 60" A.F.F. NEW INTERNATIONAL SYMBOL OF ACCESSIBILITY 6" 25 GA METAL STUDS ®16" O.C. TO 6" ABOVE CEILING LINE NOTE: NOTES PERTAIN TO BOTH THE MEN'S AND WOMEN'S RESTROOMS SCALE 1/2 " =1' -0" ENTER -ARC INCORPORATED 950 South Coast Drive Suite Number 100 Costa Mesa, CA. 92626 tel. 714.427.0370 fax. 714.427. 0375 DETAILS Sheet 6 col 02 RESTROOM ENLARGEMENTS Project No. 2864 Date 4/10/00 B.D. Submittal Bid Issue Const. Issue Revision Revision Revision A -7 BEXCISEB APR 2 5 (001 PERMIT CENTER CABINET. SECTION 6 USE WOOD PLATE @ UPPER COUNTER - -& WOOD "BLOCKING ' 0 LOWER COUNTER LAMINATED PLASTIC COUNTER TOP SHELF .EDGE CONTINUOUS 2 z -'4 OUTLET 2 4i SD W GYP BD. BOTH TU SI WALL DE (HINTED) FLOOR' LINE RUBBER BASE TYP. BOTH SIDES SCALE:. 1" = CABINET SECTION N CABINET SECTION CABINET SECTION * BREAKROOM ELEVATION Q L 2' -6" Ocri 1 Ii NOTE: VERIFY W/ KRAUSE'S DIRECTOR OF CONSTRUCTION USE OF OFF THE SHELF CABINETS AS ALTERNATE PROVIDE LOCK FOR TOP DRAWER FILE CABINET W/ HEAVY DUTY DRAWER HINGES AND CHROME HANDLES FLOOR LINE TOE SPACE SCALE: 1" = 1' -0" NOTE: VERIFY W/ KRAUSE'S DIRECTOR OF CONSTRUCTION USE OF OFF THE SHELF CABINETS AS ALTERNATE LAMINATED PLASTIC COUNTER TOP SHELF EDGE 2 x 4 CRIPPLE STUD WALL W/ GYP BD. EACH SIDE PROVIDE LOCK FOR TOP DRAWER OUTLET DRAWERS W/ HEAVY DUTY DRAWER HINGES AND CHROME HANDLES FLOOR LINE TOE SPACE SCALE: 1 = 1' -0" 2 x 4 CRIPPLE STUD WALL W/ GYP BD. EACH SIDE LAMINATED PLASTIC COUNTER TOP SHELF EDGE 1" PAPER SLOT. PAIR OF CABINET DOORS WITH CHROME HANDLES OUTLET ADJUSTABLE ADJUSTABLE SHELVES FLOOR UNE. SCALE: 1 ". = 1' -0 ". NOTE: HOT WATER AND DRAIN PIPES EXPOSED UNDER SINKS SHALL BE INSULATED. UPPER CABINET. REFRIGERATOR TO BE PROVIDED BY KRAUSE'S 4" BACKSPLASH NEW SINK. PROVIDE LEVER PUSH TYPE, TOUCH TYPE, OR ELECTRONICALLY CONTROLED TYPE FAUCETS. FIXED DRAWER PANELS. ONE ADJUSTABLE SHELF. DRAWERS. NOTE: CABINET SHALL HAVE PLASTER LAMINATE COUNTER AND FACE. - PROVIDE MELAMINE ON THE INTERIOR. SCALE: 3/8" =1' -0 ENLARGED SALES OFFICE PLAN AND ELEVATIONS V V U © SALES OFFICE ELEVATION O SALES OFFICE ELEVATION 1i• LOCK 1" PAPER SLOT CUT THROUGH COUNTER DULL CHROME DOOR HANDLES EXISTING DEMISING WALL QUAD OUTLET LOCATED ® 7' -6" A.F.F. VCT (3) 2" ROUND GROMMET HOLES AND COVERS OVERHEAD CABINET 'J' BOX BELOW SINK, SEE ELECTRICAL 1" PAPER SLOT I I7 .� c ,,l,sa1d .r �1a6 SCALE: 3/8" = 1' -0" I ENTER -ARC INCORPORATED 950 South Coast Drive Suite Number 100 Costa Mesa, CA. 92626 tel. 714.427.0370 fax. 714.427.0375 ce 0 N SALES COUNTER ENLARGEMENTS DETAILS Sheet Project No. 2864 Date 4/10/00 B.D. Submittal Bid Issue RECEIVep CrfV OF . ..i,p Coast Issue APR 2 5 2000 Revision PERMIT CENTER Revision Revision A -8 — -SALES OFFICE -4 -1- -a 4 - -1' 0 u r . P t L I �- - / . I I � . - -- -■ 3' Ii! lUii . . 2 -0 BR� K CFI 3. OOA r MIME 1 " • �� 1' 6 -0" � � - — - -i mi I CFI - 3 -3" p; I f Allh lir ® ilai gh !IV MI Mr Jiff; aNITSRIE :."(;71',Y7M5NRIZAWIE4NA CABINET. SECTION 6 USE WOOD PLATE @ UPPER COUNTER - -& WOOD "BLOCKING ' 0 LOWER COUNTER LAMINATED PLASTIC COUNTER TOP SHELF .EDGE CONTINUOUS 2 z -'4 OUTLET 2 4i SD W GYP BD. BOTH TU SI WALL DE (HINTED) FLOOR' LINE RUBBER BASE TYP. BOTH SIDES SCALE:. 1" = CABINET SECTION N CABINET SECTION CABINET SECTION * BREAKROOM ELEVATION Q L 2' -6" Ocri 1 Ii NOTE: VERIFY W/ KRAUSE'S DIRECTOR OF CONSTRUCTION USE OF OFF THE SHELF CABINETS AS ALTERNATE PROVIDE LOCK FOR TOP DRAWER FILE CABINET W/ HEAVY DUTY DRAWER HINGES AND CHROME HANDLES FLOOR LINE TOE SPACE SCALE: 1" = 1' -0" NOTE: VERIFY W/ KRAUSE'S DIRECTOR OF CONSTRUCTION USE OF OFF THE SHELF CABINETS AS ALTERNATE LAMINATED PLASTIC COUNTER TOP SHELF EDGE 2 x 4 CRIPPLE STUD WALL W/ GYP BD. EACH SIDE PROVIDE LOCK FOR TOP DRAWER OUTLET DRAWERS W/ HEAVY DUTY DRAWER HINGES AND CHROME HANDLES FLOOR LINE TOE SPACE SCALE: 1 = 1' -0" 2 x 4 CRIPPLE STUD WALL W/ GYP BD. EACH SIDE LAMINATED PLASTIC COUNTER TOP SHELF EDGE 1" PAPER SLOT. PAIR OF CABINET DOORS WITH CHROME HANDLES OUTLET ADJUSTABLE ADJUSTABLE SHELVES FLOOR UNE. SCALE: 1 ". = 1' -0 ". NOTE: HOT WATER AND DRAIN PIPES EXPOSED UNDER SINKS SHALL BE INSULATED. UPPER CABINET. REFRIGERATOR TO BE PROVIDED BY KRAUSE'S 4" BACKSPLASH NEW SINK. PROVIDE LEVER PUSH TYPE, TOUCH TYPE, OR ELECTRONICALLY CONTROLED TYPE FAUCETS. FIXED DRAWER PANELS. ONE ADJUSTABLE SHELF. DRAWERS. NOTE: CABINET SHALL HAVE PLASTER LAMINATE COUNTER AND FACE. - PROVIDE MELAMINE ON THE INTERIOR. SCALE: 3/8" =1' -0 ENLARGED SALES OFFICE PLAN AND ELEVATIONS V V U © SALES OFFICE ELEVATION O SALES OFFICE ELEVATION 1i• LOCK 1" PAPER SLOT CUT THROUGH COUNTER DULL CHROME DOOR HANDLES EXISTING DEMISING WALL QUAD OUTLET LOCATED ® 7' -6" A.F.F. VCT (3) 2" ROUND GROMMET HOLES AND COVERS OVERHEAD CABINET 'J' BOX BELOW SINK, SEE ELECTRICAL 1" PAPER SLOT I I7 .� c ,,l,sa1d .r �1a6 SCALE: 3/8" = 1' -0" I ENTER -ARC INCORPORATED 950 South Coast Drive Suite Number 100 Costa Mesa, CA. 92626 tel. 714.427.0370 fax. 714.427.0375 ce 0 N SALES COUNTER ENLARGEMENTS DETAILS Sheet Project No. 2864 Date 4/10/00 B.D. Submittal Bid Issue RECEIVep CrfV OF . ..i,p Coast Issue APR 2 5 2000 Revision PERMIT CENTER Revision Revision A -8