Loading...
HomeMy WebLinkAboutPermit D04-060 - STARFIRE SPORTS - SCOREBOARDSTARFIRE SPORTS 6800 FORT DENT WY • • D04-060 � City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 DEVELOPMENT PERMIT Parcel No.: 2954900426 Address: 6800 FORT DENT WY TUKW Suite No: Tenant: Name: STARFIRE SPORTS Address: 6800 FORT DENT WY, TUKWILA WA Owner: Channelization / Striping: Name: CITY OF TUKWIILA Address: 6200 SOUTHCENTER BL, TUKWILA WA Contact Person: Flood Control Zone: Name: TREVOR SCHAAF Address: 2111 THIRD AV, SEATTLE WA Contractor: Landscape Irrigation: Name: DUCHESS CONSTRUCTION INC Address: P.O. BOX 1985, MILTON Contractor License No: DUCHECIO21N8 Permit Number: Issue Date: Permit Expires On: Phone: D04 -060 03/05/2004 09/01/2004 Phone: 206 - 441 -3066 Phone: 253 952 -7285 Expiration Date: 08/24/2004 DESCRIPTION OF WORK: INSTALL FREESTANDING ELECTRONIC SCOREBOARD, INCLUDING CONCRETE FOUNDATION, NEAR FIELD #2. Value of Construction: $ $10,343.00 Type of Fire Protection: Type of Construction: Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Flood Control Zone: N Hauling: N Land Altering: N Landscape Irrigation: N Moving Oversize Load: N Sanitary Side Sewer: N Sewer Main Extension: N Storm Drainage: N Street Use: N Water Main Extension: N Water Meter: N Fees Collected: $326.66 Uniform Building Code Edition: 1997 Occupancy per UBC: 0002 Number: 0 Size (Inches): 0 Start Time: End Time: Volumes: Cut 0 C.Y. Fill 0 c.y. Start Time: End Time: Private: N Public: N Profit: N Non - Profit: N Private: N Public: N doc: Devperm D04-060 Printed: 03-05-2004 Z Z Q: 2 D 00, W= J f.. �LL w LL ?. � H= 11-0 Z � �5 U� ON Q H_ wW 2 u. O ui Z U =, O Z X City of Tukwila f9C6 Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Permit Center Authorized Signature: Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating constr coon r the performance of work. I am authorized to sign and obtain this development permit. Signature: Date: / Print Name: I _ ;k 1c L; e� U k �� l� rz C s , This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Z W or � UO N wi J S2 U. W O, u_ ?. CO)d =w Z� I— O Z 1— W W. �p U O N O = V, LL .. Z' CO) H � O Z doc: Devperm D04 -060 Printed: 03 -05 -2004 4.. City of Tukwila T908 Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 PERMIT CONDITIONS Parcel No.: 2954900426 Address: 6800 FORT DENT WY TUIKW Suite No: Tenant: STARFIRE SPORTS Permit Number: Status: Applied Date: Issue Date: D04 -060 ISSUED 02/18/2004 03/05/2004 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 3: Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (206- 835 - 1111). 4: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any construction. These documents are to be maintained and available until final inspection approval is granted. 5: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 6: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. 7: The score boards will be restricted to representing scores and time with no fixed, moving or animated displays or any other type of advertising panels, consistent with the letter dated Feb 19, 2004 by Christopher G. Slatt (President & CEO Starfire Sports). I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. L . y� / Signature: � Date: Print Name: A L �s�,;t., doc: Conditions D04 -060 Printed: 03 -05 -2004 z Z �W Q 2 JU cU 0 to o J = F— S2 U- WO LLQ LD D m �-W z F-- O w UJ � o U ON of WW �O W z U— H� O z � . . w, CITY OF TUKWILA Community Development Department Public Works Department Permit Center ' 80H 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Site Address: (o ti-1 O :`SITE LOCATION:. Tenant Name: Property Owners Name: Mailing Address: CONTACT: PERSON Name: Mailing Address: / King Co Assessor's Tax No.: 2.S2_ Q1 900 Suite Number: Floor: New Tenant: E) .... Yes 3..No E -Mail Address: i t sodouch • E.Orrl Fax Number: 2oc • r . 6C) GENERAL CONTRACTOR INFORMATION Company Name: Mailing Address: G City ' . — State zip Contact Person: '(t?,[X��' T l Day Telephone: _2Za. 2.0 1. J� r 74 E -Mail Address: Fax Number: Qs . 63. " 2 5 __ _ Contractor Registration Number: DucaF-C..1 O 21 r4 1 6 Expiration Date: 6/ Wbi * *An original or notarized copy of current Washington State Contractor License must be presented'at the time of permit issuance ** ARCHITECT OF'RECORD All.plans must be wet stamped by Arch>ttect of Recor "d ENGINEEROF RECORD -All plans must be wet stamped by Engineer of Record Company Name: Mailing Address - , _ __ _ City • State zip Contact Person: Q D / (� r. Day Telephone: . yy /�• E -Mail Address: k) L rj Fax Number: Company Name: Mailing Address: Contact Person: ,&,/ :dk E -Mail Address: City 16 — State Zip Day Telephone: 2e< Fax Number: �2Q• 6�� Z W D JU UO ND co W J S2 LL wo LLQ (0 D = �W Z H ° Z W w U ON 0H Ww - z W U= O Z tapplicationslpertnit application (3.2003) I �1'.•`;; + I 312003 Page i F:kDA7'!{M '�:1. �'.� +Qj' S7t . .w •T.l"4!'.?.. VY�.WfF.ns• .�... � „..tau :., .. :. �' �: i .., A{; r.. rrv. ltv vxwCw.+ . i.at..7....4 w. r..n P?p.n I' I,BUILOING PERMIT INFO ION.�"206- 431 -3670 . Valuation of Project (contractor's bid price): $ , D 1 A/ Existing Building Valuation: $ Scope of Work (please provide detailed information): CX Will there be new rack storage? E] ..Yes A. No If "yes ", see Handout No. for requirements. Provide All Building Areas in Square Footage a ow r I is PLANNING DIVISION: Single - family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? [] ....Yes E3 ..No If "yes ", explain: FIRE PROTECTIONMAZARDOUS MATERIALS: ❑.. Sprinklers n ..Automatic Fire Alarm []..None [] . Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ .. Yes n ..No If "yes ", attach list of materials and storage locations on a separate S -112 x I I paper indicating quantities and Material Safety Data Sheets. \applications \permit application (3.2003) 3/2003 Page 2 r.� Z W JU U Cl) CO LU J = H CO LL WO J LL Q _ d W Z H 1­0 Z H w U� O- 0 H- W W �O ..Z W U CO O Z PUBLIC WORKS PERMIT INF TION = 206 433 0179 , Scope of Work (please provide detailed information): Call before you Dig: 1- 800 - 424 -5555 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ ...Tukwila ❑ ... Water District # 125 ❑ .. Highline ❑ ...Renton ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila ❑... Va1Vue ❑ .. Renton ❑ ...Seattle ... Sewer Use Certificate ❑... Sewer Availability Provided ❑ .. Approved Septic Plans Provided ❑ ...Septic System - For onsite septic system, provide 2 copies of a current septic design approval by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ... Civil Plans (Maximum Paper Size -22" x 34 ") ❑ ...Technical Information Report (Storm Drainage) ❑ .. Geotechnical Report ❑...Traffic Impact Analysis ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) ❑ .. Maintenance Agreement(s) ❑ ... Hold Harmless Proposed Activities (mark boxes that a ❑ ...Right -of -way Use - Nonprofit for less than 72 hours ❑ ...Right -of -way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right -of -way Non Right -of -way _ ❑ ...Total Cut cubic yards ❑ ...Total Fill cubic yards ❑..'Sanitary Side Sewer ❑ ...Cap or Remove Utilities ❑ ... Frontage Improvements ❑ ...Traffic Control ❑ ...Backflchv Prevention - Fire Protection _ Irrigation Domestic Water ❑ .. Right -of -way Use - Profit for less than 72 hours ❑ .. Right -of -way Use — Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑ .. Abandon Septic Tank ❑ .. Curb Cut ❑ .. Pavement Cut ❑ .. Looped Fire Line r ❑ .. Grease Interceptor ❑ .. Channel ization ❑ .. Trench Excavation ❑ .. Utility Undergrounding ❑...Permanent Water Meter Size... WO# ❑ ...Temporary Water Meter Size.. WO# " ... Water Only Meter Size.......... WO# ❑. .Deduct Water Meter Size •••••• ... Sewer Main Extension ............Public Private ... Water Main Extension .............Public Private FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ ...Water ❑ ...Sewer ❑ ...Sewage Treatment Monthly Service Billing to: Name: Mailing Address: Water Meter RefundBillinc: Name: Mailing Address: Day Telephone: City Zip Day Telephone: City State Zip \applicationslpcnnit application (3.2003) 3/2003 Page 3 f Z �Z '~ W Q om? U O N W= J � NU- WO LQ _CY F- W Z1-- 1— O W �5 U� O N. o I— W S �O .. Z W CO O F- Z MEC _ HANICAL: PERMIT INFO _.NATION - 20.6 -43 i -3670 :. MECHANICAL CONTRACTOR INFORMATION Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** r Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): Use: Residential: New .... ❑ Replacement .... ❑ ! Commercial: New .... ❑ Replacement .... ❑ Fuel Type Electric.....❑ Gas ❑ Other: Indicate type of mechanical work being installed and the quantity below: U Type: . Qty.: Unit Type:. Qty, Unit Type: Qty', Boiler /Compressor: Qty Furnace <IOOK BTU Air Handling Unit >= 10,000 CFM Other Mechanical Equipment 0 -3 HP /100,000 BTU Furnace >l OOK BTU Evaporator Cooler 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan 15 -30 HP /1,000,000 BTU Suspended /Wall /Floor Mounted Heater Ventilation System 30 -50 HP /1,750,000 BTU Appliance Vent Hood 50+ HP /1,750,000 BTU Heat/Refrig/Cooling System Incinerator - Domestic Air Handling Unit <= 10,000 CFM Incinerator— Comm /Ind PERMIT'APPLICATION NOTES Appl>tcable, to all permiits in th�s;applicahon Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJU Y BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNE THORIZED AG Signature: r Date: Print Name:L`�� Day Telephone: ��� • � Mailing Address: B' 1 1 T � `� 5 Zb I — JKW I LN A' !jN 8B City State Zip Date Application Accepted: I Date Application Expires: ff Initials: \applications \permit application (3.2003) 3/2003 Page 4 Z aa� 1 UO W= H �LL WO �QQ LL cl) = F. W ? F ZO �5 U� N 0H W H� L O • W Z UN 1— _ O� Z i i �,v�►u, w �g Cit of Tukwila ! f� i 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 2954900426 Address: 6800 FORT DENT WY TUKW Suite No: Applicant: STARFIRE SPORTS RECEIPT Permit Number Status: Applied Date: Issue Date: D04-060 APPROVED 02/18/2004 I Receipt No.. R04 -00218 Payment Amount: 199.75 Initials: BLH Payment Date: 02/23/2004 12:37 PM User ID: ADMIN Balance: $0.00 i I Payee: STARFIRE SPORTS i . i TRANSACTION LIST: Type Method Description l ---- - - - - -- -- - - - - -- --------------------- - - - - -- Amount ------ - - - - -- Payment Check 1607 i 199.75 ACCOUNT ITEM LIST: Description Account Code Current Pmts ------------------------ - - - - -- BUILDING - NONRES ---------- - - - - -- 000/322.100 ------ - - - - -- 195.25 ' STATE BUILDING SURCHARGE f 000/386.904 4.50 Total: 199.75 N **? 02/24 9716 TOTAL. 199.75 I doc: Receipt Printed: 02 -23 -2004 z F= �W QQ JU 0 Cl) U) cn ~ LL WO LLQ c �. ►— _ t— O z F—. W 5: U 0. .O - 0 F— = U. U. O ilJ Z' 0 z City of Tukwila 1908 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 i RECEIPT Parcel No.: 2954900426 Permit Number: Address: 6800 FORT DENT WY TUKW Status: Suite No: Applied Date: Applicant: STARFIRE SPORTS Issue Date: i Payment Amount: Payment Date: Balance: Receipt No.: R04 -00186 Initials: BLH User ID: ADMIN Payee: STEVEN BECK TRANSACTION LIST: Type - - - - -- Method Description. - - - - -- Amount -- - - - - -- --------------------------- Payment Check 1560 126.91 ACCOUNT ITEM LIST: Description Account Code Current Pmts ------------------------ - - - - -- ---------- - - - - -- ------ - - - - -- PLAN CHECK - NONRES 000/345.830 126.91 D04 -060 PENDING 02/18/2004 126.91 02/18/2004 11:12 AM $199.75 Total: 126.91 70;:i 02 9716 TOTAL 776-49 Z ZZ W �0 UO CO) o. CO) ul J = F- Cf)U- W O U - a = W t— _ Zx Z O. U� ON ,0 H. W W. 1=- U .. Z W U =` O Z INSPECTION RECORD or 2 Re'tain''a copy with'permit o 7 INSPECTION NO. PERM CITY OF TUKWILA BUILDING DIVISION �' i 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3670 Project: Type of-Wapection: A dd r e� s: Date Cal!e� Special Instructions: Date IALnted: a.m. 1,7; -- / ""- p.m. Requester: Phon N o: (, 'Oc') ksD Inspecto Date: F� $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. I Receipt No.: Z U. 00 to a V) W W S2 U. WO 2 9 E . Ei U. < CO) C%. W Z c i f z W LL I 5 0 ca 0 -W 0 Z UN 0 Z ±- INSPECTION RECORD ,. �`- Retain a copy with permit - J S INSPECTION NO. PERMIT NO. t , CITY OF TUKWILA BUILDING DIVISION l 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 r P eject: Typ I spection: l , i� dresD C-) D to Called 3 r Special instructions: y ` Date Wa nted: Vq Requester: Phon No: * Z " �? i Approved per applicable codes. Corrections required prior to approval. S I 1 , �t I --��.• Date: � -� 1,.' Z lti.P -cat. "�' ! ��.. �� ❑ $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Z �Z '~ W J UO CO 0 w� CO u 0 U - _ CY I.. W Z� H O W ~ W O � 0 H W W H� W Z LLI U =; O Z AKU MICRO COM SYSTEMS LTD. ATTENTION ' ❑ The next image may be a duplicate of the previous image. +x: L yy x ?j 5f [� Please disregard previous image. 3 ; ❑ Please disregard previous 2 images. ❑ Please disregard previous 3 images. r ❑ Other: Z QQ S F' W WD JU UO y0 W =` S2 LL; WO U. Q Z H- F- O. Z H N O- � H W F- LL O, Z; U C(): 1-- H Z INSPECTION RECORD Retain a copy with permit -. <.....- Q INSPECTION NO. PERMIT NO. J� CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 J li P eject: Typ I spection: AQdres�s�D I� D to Called 3 1 Special instructions: ; Date Vlante d: 4- og Requester: F Phpnp No: 4 2a c e (Y Approved per applicable codes. Corrections required prior to approval. i Is I�ip ctor: j�l � ;� Date: ! � �✓ � � $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Z �_— Z W QQ 2 JU UO co W = J C0 L WO La �_D = C� �W Z H H O W H W U� O N 0 H W LL IJ U =; O Z E INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMI t. . CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Pr oj t Type of Insp ion Add es • � 0 ate Called: 3 as o Special Instructions: /I O © Date anted L a. p M. Requester: , v s ce Approved per applicable codes. Corrections required prior to approval. tor: uate: .Z.V 6 547.00 REINSPECTI N FEE RE( ED. Prior to inspection, fee must be Paid at 6300 Southcenter Blvd., uite 100. Call to schedule reinspection. Receipt No.: I Date: Z �Z JU UO W= C0 LL WO LLQ U� = �W Z� �o z i-- W UJ .gip U O N o1-- W F- �O W Z to 0 F=- O Z STARFIRE CITY OF TUNILA APPROVED FEB 2 0 2004 AS ED DIVISI SOCCER COMPLEX SCOREBOARD # Z- FILE COPY I understand that the Plan Check approvals are subject to errors and omissions and approval of plans does not authorize the violation of any adopted code or ordinance. Receipt of con- tractor's copy of approved plans acknowledged. By � ,� U � � �2� � . Date Permit N.- RECEIVED CITY OF TUKVVILA FEB PERMIT CENTER SEPARATE PERMIT REQUIRED FOR: EIMECHANICAL MI ❑ PLUMBING ❑ GAS PIPING CITY OF TUKWILA BUILDING DIVISION_ Doi - -O(Oo Z Z W J U Co 0 W UJ: LI J T : —J CO LL! w 0 :3 U. < Do S2 = d z� LU I— 0i Z h—s o Lu � Au 6 Z W co! I, i ® � t 210 wr Z F-, QQ WS UO U 0' LU J H N 0, W� �q J LL co = W H Z� H- O Z F— :O N W 0: Z. LL! ` U N° 'O H. Z 0 7 • 1tiM . deb $ Ode: •,••� Polo Em!>•dmwnt 1n W1 Peoe DNCt ptlon OX12 SCOREBOARD 0 1& Moor pas" Load duratlon factor Pole Is Round DMmdw No Surface Restraint 1,600.00 pd 1.330 30.000 in Point Load 875.00 Ibs distance from bas 15.000 R Distributed Lad 0.00 WR dbtmce to top 0.000 ft distenoa to bottom 0.000 ft MarwMs s surfians .. Point had 13,125.00 ft4 Total Moment 13,126.001t-0 DlWlbutad load 0.00 TOM Lateral 875.00 Me NMh011t surfh0e RsalhaNrt.. With surhoe RestraUlt... Required Depth GAGA R Reld Depth 0.000 ft Press ®113 Embed... Pressure a Base... Actual 372.93 pet Actual 0.w psf Allowable 372.36 psf Ati"ble 0.00 pef 3urfaoe Restraint Force 0.00 NA RECEIVED 01YY OF TUKWILA r L.1 L Zi �3 i { ✓ . PERMIT CENTER z Z` �w U0 CO) 0 Wui LL J W o, 9:3: LL ' WOE .gip OU W i I- U� . U ON ! O ~ z Tale: Deer: DeserMMba 8 �M Pole E dment in Soli DMn"M 6X12 SCOREBOARD • 1T Oonorol info W ... Max Pwwwe 1,500.00 pal Point Load Load duration factor 1.330 distance from bass Pole is Round Diameter 38.000 in Distributed Load No 8urlroe Restraint distance to top distance to bottom Momenta 41 8ur10os... Pok* Iced 15,300.00 R-# Total Moment Distributed load 0.00 Total Lateral YYllhout >surfaoe Reetra" L. With Suurfaoe PAstraint... Required Depth 6.750 R Raga Depth Prove 01/3 Embed... Pressure ® ease... Actual 386.50 psf Actual Allowable 380.02 psi Allowable Surface Restraint Force L'y- e Job N 900.00 lbs 17.000 R 0.00 STIR 0.000 R 0.000 R 16,300.00 R# 900.00 Ibs 0.0001! 0.00 psf 0.00 paf 0.00 The POP 1 CISY � ��� t�7 AP FEB 2 t�1� I�� tdv i ►-U _ i31,�t�D1i�.x RECEIVED CI'T'Y OF TUKWILA F+ r! `S PERMIT CENTER i z i� Z J U: U 0: 00 W =: tL w O, LL N D. = H =. Z� 1— O z I— O N, H , w w O' Z: U N' O z ` Job 0 Ode: lop: Pole Finb9dmang In $oil PW pdon 6X12 SCOREBOARD 0 IV MW Poe" l.iw Wi Point Load Load durstlon footer 1.330 distance fbm ban Pole Is Round DNM*K 30.000 In DWOKded Load No Surface Restraint dMUMM to fop di how to bottom a Mo -- slitallowftos... Point Wed 17,675.00 ft4 Total Moment DMUROW load 0.00 Total Lateral — WNh Swrace PlastraftlL.. wNh awrwe RwbalnL- Required Depth Un ft RWd Depth Press @ 1/3 Embed Pressure Q &w.. Actual 406.38 psf Actual Aftvable 404.94 Pat AftmMe Surface ReWaInt Force 925.00 The 10.000 ft 0.00 tm 0.000 ft 0.000 ft 17,575.00 ft4 925.00 The 0.000 ft 0.00 pal 0.00 pif 0.00 lbs F EB b Z00!j 6) , , - RECEIVED CITY OF TUKINILA 2 LID 4 PERMIT CENTER . . . . . . . . . . k z W 0. C CO) w J CO) LL � 0 9:3 U- < co D H= z f- Z 00 �- I I W UJ, :0 UJ LL liJ Z, 00. TIb: Os9ar: `� OMCf�IrOrl 1 aeope: Pfd M M 1 DacflpfHon 6X12 SCOREBOARD ! 21' Job 0 Dole: pop 1 Max Paeslw 1,500A0 Pd Point Load .. 943.00 Ibs Load duration factor 1.330 distance from base 21.000 It Pole is Round Diarnater 30.000 In Distributed Load OAO #/ft No 8urlace Restraint diatenos to top 0.000 ft diet s to boW, 0.000 ft Mowrerrls S Surfaoe... Point bad 19 ft-i Total Moment 19,803.001t -0 Distributed load OAO Total Lateral 943.00 The 1Npirout Surfaos RaNrsint... With surfaos Restraint... Required Depth 722 ft ReWd Depth 0.000 tt Press 0113 Embed... Pressurs 0 Base... Actual 419.50 pef Actusl 0.00 psf Albwabls 419.13 pet AIWA%ble 0.00 psi Surface, Restraint Force 0.00 The Cf Cr+Cn ran z w o � J U U O: . 0 0 W = N LL W O U- N �. = �. W I l- O Z F- W W ;O CO ,D H� .W W H P u. O: Z U N; O }. Z TO@ : . thpw: •i Osserlption $00ps: i Poly Fi - ibe tatMnt In ftl Daw.rip�tlon OX12 SCOREBOARD • 23 Olh: Job N Mex PaeelVe 1,500A0 Fd T POInt Load " M.00 The Load duration frct0r 1.330 dkWm from bass 23.000 R Pole Ie Round MM Swfm* ResbsInL.. DN"wer 38.000 In Distributed Load OAO WR No SUff M Restraint disWM to top 0.000 R -- 434.40. psf dkbW=to bottom 0.000 R Moasa t OR surfam - .. Point bad 22,287.00 R# TOW Moment 22,287.00 R-0 DiskilMad load 0.00 TOW Laurel we.w Ibs 1 wx" Aurlbas Raftsh ... MM Swfm* ResbsInL.. Requirrd Depth 7.682 R Req'd Depth 0.000 R Press 0113 Embed... Pressure 0 Base... Actual 434.40. psf Actual 0.00 pat Albw" 434.07 pef Albwable 0.00 pef Surface Restraint Force 0.00 The pop 1 a�ak�wty LU IRECEIVED CITY OF TUKWILA rA ' rt PERMIT CENTER M --, .......... .� � W W U O U D CO) =: J H CO W WO }} �J W ?. (0 D = W i- Z M, z W Uj r D (3 U N. O O F- W W` H L O .. z W U O z i t k? 20'-0' MAX. O STADIUM 12'-0' I MAX. O FIELD 2 I E0-_j_ 14'-0' O ST M _1 _ EQ. � N O O 2 a 6'-0' — 6' -0' O FIELD 2 i MIN= mm= mmm CONC. BASE ' f'c�2500p�i MIN. Y ' Ci" `�' GF Tu; diLA APPRU to r F 2 0 'git ° 38 ■� r�� i`��J t �U it SCOREBOARD ELEVATION 1'-0' RECEIVED CITY OF TUKWILA PERMIT CENTER SCOREBOARD ELEVATION (1 OF 3) 4� DATE: 10 -23 -03 ENGINEERS NORTHNST, INC. SHEET: 6 WO 660 ODLAW AVE. N.E. ANAL SEATTLE, WAMINGTON 98115 ,!�i Pl z ,- z WN QQ W W: UO N 0. J = H N LL W O ll. Q = d. �w Z �. F- O. z r-- W O -, o�- W Lu u. O LLi z U= O z t i �... RECEIVED CITY OF TUKWILA PERMIT CENTER TYP. SCOREBOARD BASE Starfire Soccer Complex at Fort Dent Park roNAL �G 1Q +: T.E.B. E'a A. RKM SCOREBOARD BASE DETAIL (2 OF 3) JOB No: oz118005 OiAIE: 10 -23-03 SMUT 2 ENGNEERS INC e8d1➢ 1M000LAWN AVE. N.E. • SEATTLE. KA MINGM 98115 RIES &28M ''#�� i �+,' �.�.a�„�w�� , a�+i��" � �:` �a9�M' tr' k�f" �. t '.�..�tN�±;v?!?'t7- ° t'�°R -`,C+; Yx �tE+Y'4'K.7,rc'lb+r �r�: x: �rxmtF.: �' rYk n�l.. xF c. ni� ��' �Y+:' it !q,.r+„' <3�.C:4�°.?i"e�'��£�GA, j 1 r i CITY OF TU: WUA APPROVED COL. PER PLAN F ED 20 2 ,094 A6 i : J 1 L 1 CHAMFER (6) #5 BARS VERT. EQ. SPACE wi 1' -0' MIN. LAP # TIES O 18'0% CAST BASE AGAINST UNDISTURBED SOILS Z �Z �w QQD JU UO UD C0 w J � LL w 0 u . C� = �w ' z �. �0 z�_ 25 U ON o �_ .w w �- 0 .. z. w U= O Z STADIUM SCOREBOARD N (fL) O r (ft) SUPPORT COLUMN (ASTM A992 GM) 12'-0' 9' -4' W10x30 14' -0' 9' -9' W12x30 16 10' -1" W12x35 18'-0' 10' -5' W14x38 20'-0' 10' -8' W14x48 FIELD 2 SCOREBOARD 'N' (ft,) O O r 00 S SUPPORT COLUMN (ASTM A992 GR50) 12'-0' 6 6' -8' W W8x18 14'-0' 6 6' -9" W W8x24 18 7 7' -1" W W8x28 18 7 7' -4' W W10x22 20'-0" 7 7' -7' W W10x30 I'll �'�:' ^4r�1` J �N r RECEIVED CrrY OF TUKWILA t Ly' t PERMIT CENTER i i !1!t'lPB4✓fi' 7wv 7wra 2. ?�r+ tJ.'.'* ?? a^ nwwrm^ K+'* 4�x^ n"-` xM• e. rr+ rw�.•,+.ay.�.:.r• < , wrrr:. a+ nsepitun; ...» kw- nn.. v+ �.= vs+l r"' f" �: !t�+r,.+r.'dYYg1�'iT." ..w Z ,0- Z uj J 0' UO co) 0 w= J � S2 u. W O }r LL J : z d FW ? �o W �. .moo o -, oF- w F- O: til Z U Co): O Z E NW ENGMUM NORTHWTST, INC., P.S. S TRUCI'[IKAL E NGINEERS ' 6W woaouwN ASE. N. B.. #203. SEATnE, WA 98115 (206) 525 -7560 FAX (206) 322 -4M PROJECT 0 PROJECT �dI�CS DATE 3 SUMEC'f' G ✓W ", D � S� �t ! 'l� (. SHEET OF Z B y �, D UO c l) O r J111 r. Co) U_ y Eb y .. _. _.�.�.+�1 '� .� �'v,�► e 5 �F � o = a UJ 12 o D V= 3 P z Mo o� I � • Z� - p � 1� fl I.G►•�t.�#) Eip�i� ��•3 115 D � VJ$�t$ G•� ► W w 14 'x' �� 1�,4C.1•w) x,01) , 0 1 � I �o w bh 4pe 7s r � n i r► 1 l�� - o� r I q -o ! { � I�.Iti " 2r,, psi I $ s o Won �. 27 � �. 0 t $ -� Z(!• Q.' llo:�� j,y) 1� 14� = �.1�, Z- psi i voso wlo�zz- 7 N Z D" z3!�' j�►qj. G.I�) " PS'f 1431 * V�►w�1`30.1. 0 z pECEiVitdl r, ert�r of Yu►cwit.A 960 P FIMIT CF_INTER ��.�'� 1�.4z il►•�F (I,rt)f 1���� =�F 4y>D3 wi�cx q�ea 10. q Z t k +I- *f af)c"'O i G 96861 -8 L 0 a -0801 L'- 'n 13o tiZ -31Yo 3nilm us Nww OS 'SJNIN0088 •3NI 1�dnT 711 TSdD.t l 0 ON C 'SWM A All : ■rlb Si , NO IIb6 Lvnm 'ATNO ON3 AV Ids10 311 s3llr::TNOS K% KIM3 O1 031r1�W31 38 lSrin erl TY H3ddW TTY io 01J1S 3N! 310N s.a3nvlsa 3H+.OHrN 031W)On ATwNa31N 3HYMOHYH 031w10n ATlnW31X3 - WIX SWU HOJ ONVAYH0 dOHS n31SAS 3HI 37N3H3J3H 3W'id 'SW130 1N3n33Y1d AryS10 WM3Y HOJ ' MYW Su11 33N3H3J3H ION 00 '1N3rkW03 Sl/u J0 NWVMI OtALN 0 _MWN30 Y S1N308d3b 3NMIYH0 SINI - AHrA AYn 'S13Wd 3onds Ow s.3/v somoe MWd Sr MOSS 'StN3N0dn03 T D(=313 JO 1N3n33Y1d TYnt3N . ,.Iw S33N3H313H Hoi 03sn 38 O'XIONS OW S3un t8SNOdS3H 3NIna3130 01 03ON31NI ION Sl ONMY110 SKI '03T?VLW 0731! Sr 0315n SM311 H0J 378SN0dS3H S3uHYd 110 AlHYd 31I 3/r1/W MA iN3n3383Y 7Yn12Y8Ut03 311 '3NwVw hyd2 10 H35W O31Yodn "" 3M038 , nw OW 13NNOSb3d WfM S3WOMM H11A1 MSSrt3510 38 aWH5 drIM HOW 00 l0r onM 01 30M S3ONYH3 ANY 'NMp6 dn135 Ow IN3nd1103 3H1 01 031!03,5 3HY SLN3n3wo3H 'Nomm CRY H3MOd - mHDM 03 WSW n3lSS SW1 w MW ION 3w S3HOa3308d AVVSS333N WH10 HO mllJMO N336 31%YH Sd3IS NoarlMiSla d AtNBYn oN S3nMSY '3N 'SowoH111w SS SNX13nH15Nt 353HL SLOAM s3wo11x.G 3fgntn Sr NOIlYrIMW H3Y3 3S 038 , n3LSAS AYtdsq 3H1 01 n31SAS Au3ml30 maw 3m Jo AlrM10 311 HW 7186NOdSU 1ON S1 S3ogHLr4 'CERG93A0 38 01 3AVH AM (S)33VM NOa33111Hd IWAMM 113A0 3H1 'dnImis NO 1N3ndM3 AYIdS10 3HL AS 03IM3 (33NIS AHY1rr3n0n) iN3 um msnum 3HL of 300 1 03LDVIAM 39 G S 3AUr1x3532 d S38XXU 0 r 'Sd11Y DWO r S033M n3LSA.S TYJQW3T3 3H1 N iN3&M 1TWJ TN YMAY 311 A - GNNOSH3d 03urWno AS 31S Hr10.1 1r 031WOJH3d 38 01 033H AYn ATAIXS 1K3MM llfWJ MEM NY 'IrOM J0 L731Wr13 limn 3wY1YNI 3m 3NInam 01 '013= AH3AM H3MOd 3Hi N 31BY1NAr SI Mil 1N3WM IT WA 311 01 03WIY11 38 LSr" 33KT0 NOtr3310Hd IN3HN13 H3A0 3N1 'S30KAUXY0 AB 030Y.08d ION JN3ndM3 GrIckl K S3040HIM HU '1 AW= H3MOd ounoHo SnHo 01 NY1I 30M ON 11M 3003 TY3W13313 70N011YN 3HI J0 009 ONY MZ 3mwiv Had 03awvt3 3e Ism s1Yld9a TTY 'AINp 01A0 H3153HHN 33Hns 310Y3 TYNOLS 311 lY TvNnW31 al3ets 301 01 030N1089 SI 3" 01355 3111 mu 3HnSN3 10 1SAS Hn01 N 03zrKLn st 3TeY.1 wNOS 013116 'SnCYtl ON38 1 nnn*M r HIM SIXNYNINO3 38 1Snn sww 37013 3ud0 kaW 'N)11YN1$30 OW NOW 01 SY aMDn 38 axldrs sw w Too WN= TTY 7YNOU WWI aw WI Tw 80 SIMPI 315 NO 031WOAW XHO. WOMID313 TTY XVHI 3HrSN3 0l 8013Yd1H03 MMVT Y15N WDWt33A 3H1 JO mn8WJ0dM 3H1 St L A'M S1N3n3W1032f www ow H3MOd Hoi a35n 3e MONS ow 3Nmw a3MJs V ION A s■u 00 149 T/dd. --- 1 3013N :a T30 1 3 ama n3LSAS -nm I I MOdS 3813SV1S DOM= MUM 0 MAM 09M RN aR 'AM17d0W r ®IOO LdZMW 3N1 1 I I 1 L-- 31V0 311LL 03NOIS �ANtldYdO3 11W9nS3b 8 nu3Lo(J SV 3SIAli =' Q O;li:! SV 03A04iddtl 03AOaddV M31A3a - mu imns d " n TS S1r N0 vv e�nlcnunvin vv�c...� , ..n �3 332H1 11V '0113 + SUVA Y OVA AOWOZl AHYMMcf- MV1 a 0010 00 WNH31N1 r � AS 03OV W NOUROS38 r I IfY I roNVd OY J HgSOHd A KZ- 911X09 13NYd 0Y LV mwd HOsNOdS r . m r: I .—�� r Qn M m cc z r ^ m -i v -) i Iml 9v TS S1r N0 vv e�nlcnunvin vv�c...� , ..n 4v rti. YIN AMNODM-33r1T0A 9z0'9 SLIrM nrwcm z2 3Nn Had MH3dr1Y 332H1 S3svl4d JO / '0113 + SUVA Y OVA AOWOZl AHYMMcf- MV1 •]Jtw"m Vw1U 1nr1 -r I - MCt -. I XH mul sowouUIYO XH/X1 zCZsu X! H YLIO- S901 -w H3LH3ANM WNOS H38U t Stoo-l9ll - Z. E1 911 Nr10T03 9t '19 MOH NOLLYH031JNO3 H3Indn03 H woo1- 60011 - 20 A /N07n A OOOLA 20 1 »Z -TT 000 - 9611 - w O ❑ 1011 3003 o,rz-n To' O Q H3LWMO 1NOW NO 031w01 L I aolINOn 180 -St �+ i OSCt -V 1,- K a W - - n t I 00b 10HINO3 ORFUL 01 a3riolsno Aa NounG181SIO NrM M31A 8V321 a sowouUIYO S3X08 -r roNVd 0r 0 l4V L roNVd Lv 13VA P a 0010 00 WNH31N1 r � AS 03OV W NOUROS38 r I IfY I roNVd OY J HgSOHd A KZ- 911X09 13NYd 0Y LV mwd HOsNOdS WWZ - 9L LX08 I NJ sowouUIYO S3X08 -r roNVd 0r CLr -11Y 1711-1 $JIr10H1)IY(I roNVd S3S Hd JO / 13VA P sown m 0010 00 WNH31N1 AS 3TWiM AS 03OV W NOUROS38 iN3NOdMOD • H3noisn3 A8 TTv15N1 Ol a 08v1 )p '1InaNO3 'Saolonalloo aQ ainONOO NI llnom OVAOZL dRVSl 't • a3n01Sn3 AS S318VO TTVISNI 01 HOW ONV vnONO3 ' SZO dAl (4ZZl-M) SOINOa1NVa A8 3't8v3 Q •IinONO3 N1 31m a30113HS OMv ZZ alvd -Z 't a3noisn3 A8 llV1SNl 01 a 08v1 V '11nONO3 '318v3 •llnoNO3 N1 (a38U 300nulnn eQ Slt /929) 31811! 3udO N38U 'a38U 9 't •a3no1Sn3 AS 03TTV1SNI 1 Y OMS iinONOO 1 P Sa013naN0O Q lInONO3 NI (aN0 + S38IM 0 lln3ai3 OvA Asoz /ort 't •S31ON NOTICE: IF THE DOCUMENT IN THIS FRAME I LESS THE D OCUM ENT .. T AN THIS NOTICE IT IS DUE TO THE QUALITY r/N AHwN)73S- 37r110A Z99'6 -%uvm wnrclrn Lz 3N1 Had S3S3dMv 33HH1 S3S Hd JO / 'OND + S311IM t 3 AWZ /OZ1 Ab'" Wd- 3OYITOA G� 0 9t l -00'13 -080 l l 04 `` ' DD :u vr+ n N<mr 5 L mw XIWI as Iwvo XIWI Us I 900L9 OS 'S9NIX0088 - 3N1 - S31N081XV0 7r anodlr.0 rwr mmum mw 'LiRIr m )0 1 zmw NL1AlN 03CDNM 3a YIOH3r++ ATN'JOICRi1 aortw 'SWI. A AS 10N 00 'APN11M1rd OW WN30LMM 3N SMW sw NO UMS MW OW OESISU Ltrlxm 341 53lDNV .4/ l 38n1/SAY1dS10 3o Wolloe� .0 -.0 - S'0'1.£ -.0 A1ND 3SOd8nd 1d33NO3 H03 NMOHS 38n1 . - -38n1 ..F 30 3sn NO 03SVS 3NV SNOISN3W10 1331S- 30 -dO1 T1V 310N "S'0'1..Z /t f -.9 'S'0'1..Z /t t -.8 1ro130 33S HO,dWDM I 3n0 I WW 11V NO 03Sn 3MOH S 08D .Z /t H11M 08V08 X181VW NO 035n S31ONV d113 13315 .9 /FXfXZ XI81V 30 '/"' 83ddn Sl 13NVd 80SNOdS /Ov NO 80SNOdS 30 S31ONV dno ON3 63MOI 13315 .4 /txZXZ 3 1ro13o 'AV1d510 30 n01L08 ONY d01 1V 031V301 13NVd 831113 .9 v - A WtSNOd538 A1NO S.83m== 3H1 323V WXLV - 33 V 9201530 3Nnormt5 '3animms Tri t C 'NO1.9NtHSvA1 30 3LVIS 3H1 M 03SN33n 2I33NtW3 AS 03011M ONV 3N00 •NoLL3nH1SNO3 nnNlnnw r S I A YLd51 0 38 01 NOG30 WnLOY *XIN0 3SO&M 1.03"00 203 SI NMOHS 32YuDref15 Try 'Ot :SHON 'MI ONLH 3H1 SWH ONV 3NIN2 MMM AY1dSt0 151S3H iSnn 1N3nH3v11y MldSM d01 3H1 '03120ddnS L SnDnN0NO3 38 isnr% AY1dS10 V 3o MUM 3H1 '6 Oil MON 33S 'Ol 03LNnon SI Avid510 3H1 IWU 38n13nH15 - - NMOHS 38n1 3H1 30 A.LQM31M 1VHn13naLS 3H1 Hoj 37815NOdS3H SI MO1Sn3 •8 G� 0 9t l -00'13 -080 l l 04 `` ' DD :u vr+ n N<mr 5 L mw XIWI as Iwvo XIWI Us I 900L9 OS 'S9NIX0088 - 3N1 - S31N081XV0 7r anodlr.0 rwr mmum mw 'LiRIr m )0 1 zmw NL1AlN 03CDNM 3a YIOH3r++ ATN'JOICRi1 aortw 'SWI. A AS 10N 00 'APN11M1rd OW WN30LMM 3N SMW sw NO UMS MW OW OESISU Ltrlxm 341 53lDNV .4/ l 38n1/SAY1dS10 3o Wolloe� .0 -.0 - S'0'1.£ -.0 A1ND 3SOd8nd 1d33NO3 H03 NMOHS 38n1 . - -38n1 ..F 30 3sn NO 03SVS 3NV SNOISN3W10 1331S- 30 -dO1 T1V 310N "S'0'1..Z /t f -.9 'S'0'1..Z /t t -.8 1ro130 33S HO,dWDM I 3n0 I WW 11V NO 03Sn 3MOH S 08D .Z /t H11M 08V08 X181VW NO 035n S31ONV d113 13315 .9 /FXfXZ XI81V 30 '/"' 83ddn Sl 13NVd 80SNOdS /Ov NO 80SNOdS 30 S31ONV dno ON3 63MOI 13315 .4 /txZXZ 3 1ro13o 'AV1d510 30 n01L08 ONY d01 1V 031V301 13NVd 831113 .9 v - A WtSNOd538 A1NO S.83m== 3H1 323V WXLV - 33 V 9201530 3Nnormt5 '3animms Tri 1314levo 'NO1.9NtHSvA1 30 3LVIS 3H1 M 03SN33n 2I33NtW3 AS 03011M ONV 3N00 •NoLL3nH1SNO3 nnNlnnw r S I A YLd51 0 38 01 NOG30 WnLOY *XIN0 3SO&M 1.03"00 203 SI NMOHS 32YuDref15 Try 'Ot :SHON 'MI ONLH 3H1 SWH ONV 3NIN2 MMM AY1dSt0 151S3H iSnn 1N3nH3v11y MldSM d01 3H1 '03120ddnS L SnDnN0NO3 38 isnr% AY1dS10 V 3o MUM 3H1 '6 Oil MON 33S 'Ol 03LNnon SI Avid510 3H1 IWU 38n13nH15 - - NMOHS 38n1 3H1 30 A.LQM31M 1VHn13naLS 3H1 Hoj 37815NOdS3H SI MO1Sn3 •8 1331S /CXfX£ •(V3HV 3N13V .1 x .Yft) 31n00n .9t -- S838W3W — H3d 03OLN08d 3B ISM 31nNln Had 133! 318113 8Z '13M8YO 03SOION3 1VINOZ180H 3H1 01m 033H03 38 1Snn M -11 "a3HIno3H 38 Avn 3Hn13nti15 o3SOl3N3 3H1 jo N011YVIN3A 033H03 '3Nn000 31vn030V HOj - JWUOMJ.S 3H1 M S'.)NIN3dO 3H1 0N213A03 IVIH31Vn 3H1 NI N3310S 30 33V1N33d3d 3H1 203 31tSN3dn03 01 30M 38 ISM S33WIAOTIV 'ONf1003 AVId510 31vn030V 3HnSM O1 O30v,OHd 38 Isnn 31no0n Had ONw3d0 o313ndLS8ONn jo S3H3NI 3HVnOS 91 'SNOUMltS 13NOY3 03SOI3N3 NI TolLYIUN3n 'Z "S3HONI V 1333 NI 3Hv SNOT Wma TIV '9 T=nblS80 38 lON NVO ',WdStO j0 W8 NO 'SOOOH 13IN1 HIV •S '83n01SM AS 03HSIN8nj 38 01 133NNO3S10 lr,)H133I3 NW" Y •oHYoe x1divvl jo X3v8 NO 8 0 3Hn13n8LS 3NLLNnon dAi .4 /£ £ -.0 - 9t /C Z -.l 0 -, t sr3N+a1 �— a 1M130 335 v Tr=v O1 - hm3w ouNnon 38 Nv3 (ms=38 31) MIND Oral 'r S13NVd .. 'H30k90 'o 3A1 xv S537OY W38 HD 1"OHj AJOUS I" nOA '1N31313i3 38on 38 Avn S5333V 1NOH3 'AINO 1NIOdONYIS AYIdS10 805"0.5 /OV NO / 3H1 nOH3 1118 'SS333V Hd3H 20 1NOW 80) 03ND1S30 38 NY3 AYId510 • Z 't S31ONV dno - / •NoLL3nH1SNO3 nnNlnnw r S I A YLd51 0 13315 .4 /tXZXZ :SHON M IA IS Ott 31ON 33S - -NMOHS 38n1 13315 .9L /£X£X£ -- S838W33v - 1VINOZIHOH .0 t j � .B /f 4 -,0 NOTICE: IF THE DOCUMENT IN THIS FRAME IS LESS CLEAR THAN THIS NOTICE IT IS DUE TO THE QUALITY OF THE DOCUMENT. dU S13NVd BOSNOdS 30 4 _ _9I /£t 8 -.0 ON3 83ddn MhdO1 zswn.n iwas vo sxo.0 laowa Iw -0-s Wro n. vim" ./r 31Vv 1!�r;srs3e z e�1oN s� % 311^,12 S'� 031 A131A38 IVJ -LI14 1SM,00 NWYKIN 3A LX181VW 30 W311 NO 031NnOW 08V08 l3NVd Mv M h 1 H3 I I CIVVSL x .OWZe 581 OZt ' t w �� 'X08ddV 1 v3 'XO X08dd V .Z /t £-.9 8 OV 301S I OV OS l8 .Z /t f - ,8 S81 OtZ 'XOaddV .0 -.z 13NYd NOSNOds InXOV8 ,OZ X .0 -,Z V .0-.OZ �'•Rbu335 SOOOH Swim NOUYUN3A OMM SOl31HSNM_ J 2t3111i /NVd W313 Ol d330 .9 30 W/tt11NIM 38 01 033N nuA Hid30 S.m38r13L7 IVIWZWH '035n sl DNMJVdS 3 -3 N11n 103 M3TMIS 31 31ON Ott 31ON 33S - 0N13VdS 3 -0 .4L 1V 1d33NO3 803 NMOHS SNrimoo 13315 04X8M 11:1 IDS d r,03 L1 �1 S tarf i re Sp6fts R Washington non - profit corporation February 19, 2004 Mr. Steve Lancaster Director, City of Tukwila Department of Community Development 6300 Southcenter Boulevard Tukwila, Washington 98188 -2544 FILE COPY Re: Starfire Complex Outdoor Scoreboard Installation Steve, This letter serves as confirmation of our agreement that the two soccer scoreboards being installed at the Starfire Sports Complex at Fort Dent Park will initially be restricted to representing scores and time with no moving or animated displays or fixed or animated advertising panels. Consistent with the Concession Agreement between Starfire and the City of Tukwila, Starfire intends to submit a signage master plan to the City with the intent of obtaining approval for full, unrestricted use of the video scoreboard and placement of permanent advertising panels in selected areas of the complex. Until this approval is obtained, Starfire will operate under the restrictions identified above. Thank you for assisting us with this project.. RE CFJ\JED �A CITY OF Sincerely, FEB 19 2004 pER�11-r CcN "►EF? Starfire Sports Christopher G. Slatt President and CEO Doi -ono 6840 Fort Dent Way, Suite 125 • Tukwila, WA 48188 • phone: 206.431.3232 • fax: 206.431.6811 www,starfiresports.com z 1 ;F- w u� = U O J = cn ,,.: w O LL Q. �a �_ z� �o Z U ;o o� W W` - OP ui z CO) 0 Z PERK IIT COORD CORY PLAN P"I B/V/R0 U T1 N G SLJP _X _ Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter if Revision # After Permit Is Issued Buil inDivis n Fre Prevention ❑ Planning Division i Public Works ❑ Structural ❑ Permit Coordinator (Tues., Thurs:) DUEDATE 2 -19-04 Complete Incomplete ❑ Not Applicable ❑ i Comments: i Permit Center Use Only I NCOMPLETE LEiT6t MAI L®: LETTER OF COMPLErEN ESS MAI L®: Departments determined incomplete: Bldg ❑ Fi re ❑ Ping ❑ PW ❑ Staff Initials TU ESITH U RS RO U G: Please Route Structural Review Required ❑ No further Review Required ❑ REVIIBIVMS IN ITIALS DATE Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIMUTS INITIALS DATE Permit Center Use Only CORRECTION LE171782MAIL ®: Departments issued corrections Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials Documenlslrouting siip.doc 2 -28 -02 z W JU 00 NO J � C0 U _ w LLQ �D = I .. w Z w� 25 U� o� wW H� LE:O W UN 0 H O z