Loading...
HomeMy WebLinkAboutPermit D04-112 - SOUTHCENTER MALL - T-MOBILE - TENANT IMPROVEMENTT- MOBILE 757 SOUTHCENTER MALL D04 -112 z cc JU U O: • 0 W= 1- (A LL. w O} g lL < d; F=-_. F- O' Z H; w w U �. N O -� W • w U. - - llJ - Z H 0 1 z g City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 DEVELOPMENT PERMIT Parcel No.: 2623049023 Address: 757 SOUTHCENTER MALL TUKW Suite No: Tenant: Name: T- MOBILE Address: 1127 SOUTHCENTER MALL, TUKWILA WA Owner: Name: JG SOUTHCENTER LTD Address: 25425 CENTER RIDGE RD, CLEVELAND OH Contact Person: Name: PAUL LAWRENCE Address: 250 S 5 ST, BOISE ID Contractor: Name: BUSH DECOR & FIXTURE Address: 3949 W YORKSHIRE DR, SOUTH JORDAN, UT Contractor License No: BUSHDFI005LR Permit Number: Issue Date: Permit Expires On: Phone: D04 -112 05/06/2004 11/02/2004 Phone: 208 429 -4034 Phone: 801 - 280 -0424 Expiration Date: 01/18/2006 SCRIPTION OF WORK: DEMOLITION OF EXISTING STOREFRONT, NEW STOREFRONT, INTERIOR (NONBEARING) PARTITION, FLOORING, CEILING AND LIGHTING. Value of Construction: $ $60,000.00 Type of Fire Protection: SPRINKLERS /AFA Type of Construction: VN Fees Collected: $1,182.19 Uniform Building Code Edition: 1997 Occupancy per UBC: 0023 Pu blic Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number:. 0 Size (Inches): 0 Flood Control Zone: N Hauling: N Start Time: End Time: Land Altering: N Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: N Moving Oversize Load: N Start Time: End Time: Sanitary Side Sewer: N Sewer Main Extension: N Private: Public: Storm Drainage: N Street Use: N Profit: N Non - Profit: N Water Main Extension: N Private: Public: Water Meter: N ** Continued Next Page ** doc: Devperm D04 -112 Printed: 05 -06 -2004 .. :..v lJ " "'r�' ,. ., ., , :tv •'� �'�K1 t�1 x� }y�:l�e+• `�.W .Jlcu:.:a,ti�untisa.AiLx' W.a.. s'..i"�.!..u:.�il.uw5.i.ilca �u.r�iauxa'+: W.w�Wtt.:w.xx "� Z Z � D 00 N CO) J � CO) L w J LL? co C% = w Z' HO Z f- w �5 U� O N off w �O W Z U= O~ Z City of Tukwila 19Q6 Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Permit Center Authorized Signature:- Date: S d y I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating constr on or th perfor ce ork. I am authorized to sign and obtain this development permit. Signature: Date: eL � D Print Name: - ,= /5 1 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: Devperm D04 -112 Printed: 05 -06 -2004 Z w a 2 JU 0 CO 0 w� S2 LL wO LL CO) a 11-- O Z 11- w UO O CO o H- wW L L .• Z w U= O H Z City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 PERMIT CONDITIONS Parcel No.: 2623049023 Address: 757 SOUTHCENTER MALL TUKW Suite No: Tenant: T- MOBILE Permit Number: Status: Applied Date: Issue Date: D04 -112 ISSUED 04/01/2004 05/06/2004 1: ** *FIRE DEPARTMENT CONDITIONS * ** 2: The attached set of plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 3: Maintain fire extinguisher coverage throughout. 4: Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5) 5: Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 1207.3) 6: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (UFC 1207.3) 7: Exit hardware and marking shall meet the requirements of the Uniform Fire Code. (UFC 1207 -1212) 8: Maintian sprinkler coverage per N.F.P.A. 13. Addition /relocation of walls, closets or partitions may require relocating and /or adding sprinkler heads. 9: Sprinkler protection shall be extended to all areas where required, including all enclosed areas, below obstructions and under overhangs greater than four feet wide. (NFPA 13- 4- 5.5.3.1) 10: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recorgnized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1901) 11: Contact the Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1900 and #1901) 12: All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 13: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. 14: Accumulation of combustible waste material is prohibited during the demolition phase of this project. Remove and properly dispose of all waste material prior to the close of the working day and as often throughout the day as needed. 15: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of doc: Conditions D04 -112 Printed: 05 -06 -2004 .- fu�.._,.,_,.,_.4...�.._...� , w�......,.........._,.-_......, r�; AF„ �� ^�!!����,.,t�„`�t:- ���'��'..... r:', �... n. �# t85�1F�' n} �,•. x�+ � _:x!�'A�� rwfl!�nrruaaraaa*a€a�a+ sir.+ Deske�ra "2!s€M:1 k'tsR1(f4� 4� n7it�l J Z ~ w L L. JU 00 Cl) C0 W J = H C LL WO LLQ CJ) D = �. w H Z' H 0 Z �5 U� 0� off wW LL 0 w Z UN 0 Z ..g City of Tukw race Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 such condition or violation. 16: These plans were reviewed by Inspector 512. If you have any questions, please call Tukwila Fire Prevention Bureau at Q (206)575 -4407. ;F=- w 17: H.V.A.C. units rated at greater than 2,000 dm require auto - shutdown devices. These devices shall be separately zoned v in the alarm panel and local U.L. central station supervision is required. (City Ordinance #1900) 0 0 18: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be co F equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the CO L air - moving equipment upon detection of smoke in the main supply -air duct served by such equipment. Smoke detectors w O shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (UMC 608) Q co o 19: Duct smoke detectors shall be capable for being reset from the alarm panel. (City Ordinance #1900) = CY F - w 20: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #1900) ? F- F- O Z F- 21: Call the Tukwila Fire Department at 575 -4407 for approval of any system shut down. Have job site address, name and LU Uj Tukwila Fire Department Job Number available to confirm shut down approval. (City Ordinance #1900) v o ON 22: ** *BUILDING DEPARTMENT CONDITIONS * ** O H w 23: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. F �0 24: Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical W Z Co work will be inspected by that agency (206- 835- 1111). v O 25: All mechanical work shall be under separate permit issued by the City of Tukwila. Z 26: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any construction. These documents are to be maintained and available until final inspection approval is granted. 27: Any new ceiling grid and light fixture installation is required to meet lateral bracing requirements for Seismic Zone 3. 28: Partition walls attached to ceiling grid must be laterally braced if over eight (8) feet in length. 29: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 30: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. 31: There shall be no occupancy of the building(s) until the final inspection has been completed by the Tukwila Building Inspector. 32: Ventilation is required for all new rooms and spaces of new or existing buildings in conformance with the Uniform Building Code and the Washington State Ventilation and Indoor Quality Code, Chapter 51 -13 WAC. doc: Conditions D04 -112 Printed: 05 -06 -2004 a w '' .... T St ;�W { A ?F1 Fe a !' ak .M?wE'AraaS * nrxr+ rnrawatme v � �attc cMaa.�m. wr ?e� i f f I' 1 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performanc work. Signatu Date: i�)S � d Print Name: S& z W JU UO CO 0 J = H CO W. WO LL ?. CO a. H— Z , �. F- O' Z f-: W 25 U O N �H W H W — O! .. Z W U =; H O ~' Z I Wiu, 1 f CITY OF TUKWIL4 Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 - Budding Niffiit ' Mecliamcal'Perniit No. Public V�orks Permit N f Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION 1 CONTACT PERSON '71l� King Co Assessor's Tax No.: I v 6. 230 �" Fa "> 3 51� 3 Site Address: —CPM y i(`rl au Suite Number: 25 Floor: � S~t � 1 2 Tenant Name: - r -. YY10 !P21Lt° New Tenant: .... Yes E] ..No Property Owners Name: - Ne4f Lej d ��ltj Pflt� 2a�S2� hS Mailing Address: J�p0) W (1-S ti6 - p) Tel v - t �.� LZn l b)5 Prn CAeS (_'�A . q O o ZS City Stale Zip 1 Name: Rut.. _(Akk) Yl gyp_ Day Telephone: 40 - 4 L%- 40 Mailing Address: _ -2 5, S 5T T-�?Q (S-e- 830oZ City State Zip E -Mail Address: Fax Number: 1,6?2- -�74;3, - 4{0 �;% I y GENERAL CONTRACTOR` .INFORMATION ,�. -t 1, Company Name: TBD -5� Mailing Address: Contact Person: E -Mail Address: City State Zip Day Telephone: Fax Number: .ARCHITECT OFRECORD - All plans must be wet stamped:by Architect of Record Contractor Registration Number: Expiration Date: "Aft'- orf [ yVy } i # *# 3 ' / ma y ` " t . �� ' ]]( { ' ] ( ] .#3i ] ��y fQft: iltit c i eeCtse musf se` f { ' re5enfed ' � ` jr : � ,(L7{i ' y ' , � 1 : : ' :e fi>r eriiiiti ssuanee'�:* . •.• �•:.•� \•. ••••.ii: •: Ni•V•t ••. •1•• -•(•� ' T". At•• 11.• lJY: f••• V• t••.•••.••• it1••••••.•.••••:• Vl• t•.••.••••••..••. .tl` .............•!CT.'Yf1Y.:MM Company Name: CS 4&y) wGlt! j Mailing Address: 5. ��% $f ''Jd i -1 4 . 837 aL� City State 'Lip Contact Person: Day Telephone: Z01- 4 ZR. I E -Mail Address: Fax Number: 4<4 7 , , 8 ENGINEER OF RECORD = All plans must, be wet stamped by Engineer of Record. Company Name: 65t+_� 7►f_4_ S. W t DN bv- G r Mailing Address: ZrJO 5 . jf5 7r �d f� Ste! g�7 _70 Z City State Zip Contact Person: Day Telephone: - 4 Zq - 40 q E -Mail Address: Fax Number: ZOl - 46 \applicalionApennil application (3 -2003) 312003 Pilge ) tF Ski' rit, UaK+ VKt7. 4: wi, w..:v�vrx..,.v..».....,.....n «.:.,r.:=..0 .. vaw. �r..: uzww. n..-. A... xe.: , ::.r.,- «ia= .r:,«n.•�. �ci:tr�:c'.:,;.a.�: '„�.+eir;ai,i �rt;.,y' t Z ~ W JD UO U W= S2 LL W J U. Q NCY CY F W Z z� W W D Cf)_ 0 H_ W H C - ) W Z iii U= O Z i i,` •,v 1 - Budding Niffiit ' Mecliamcal'Perniit No. Public V�orks Permit N f Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION 1 CONTACT PERSON '71l� King Co Assessor's Tax No.: I v 6. 230 �" Fa "> 3 51� 3 Site Address: —CPM y i(`rl au Suite Number: 25 Floor: � S~t � 1 2 Tenant Name: - r -. YY10 !P21Lt° New Tenant: .... Yes E] ..No Property Owners Name: - Ne4f Lej d ��ltj Pflt� 2a�S2� hS Mailing Address: J�p0) W (1-S ti6 - p) Tel v - t �.� LZn l b)5 Prn CAeS (_'�A . q O o ZS City Stale Zip 1 Name: Rut.. _(Akk) Yl gyp_ Day Telephone: 40 - 4 L%- 40 Mailing Address: _ -2 5, S 5T T-�?Q (S-e- 830oZ City State Zip E -Mail Address: Fax Number: 1,6?2- -�74;3, - 4{0 �;% I y GENERAL CONTRACTOR` .INFORMATION ,�. -t 1, Company Name: TBD -5� Mailing Address: Contact Person: E -Mail Address: City State Zip Day Telephone: Fax Number: .ARCHITECT OFRECORD - All plans must be wet stamped:by Architect of Record Contractor Registration Number: Expiration Date: "Aft'- orf [ yVy } i # *# 3 ' / ma y ` " t . �� ' ]]( { ' ] ( ] .#3i ] ��y fQft: iltit c i eeCtse musf se` f { ' re5enfed ' � ` jr : � ,(L7{i ' y ' , � 1 : : ' :e fi>r eriiiiti ssuanee'�:* . •.• �•:.•� \•. ••••.ii: •: Ni•V•t ••. •1•• -•(•� ' T". At•• 11.• lJY: f••• V• t••.•••.••• it1••••••.•.••••:• Vl• t•.••.••••••..••. .tl` .............•!CT.'Yf1Y.:MM Company Name: CS 4&y) wGlt! j Mailing Address: 5. ��% $f ''Jd i -1 4 . 837 aL� City State 'Lip Contact Person: Day Telephone: Z01- 4 ZR. I E -Mail Address: Fax Number: 4<4 7 , , 8 ENGINEER OF RECORD = All plans must, be wet stamped by Engineer of Record. Company Name: 65t+_� 7►f_4_ S. W t DN bv- G r Mailing Address: ZrJO 5 . jf5 7r �d f� Ste! g�7 _70 Z City State Zip Contact Person: Day Telephone: - 4 Zq - 40 q E -Mail Address: Fax Number: ZOl - 46 \applicalionApennil application (3 -2003) 312003 Pilge ) tF Ski' rit, UaK+ VKt7. 4: wi, w..:v�vrx..,.v..».....,.....n «.:.,r.:=..0 .. vaw. �r..: uzww. n..-. A... xe.: , ::.r.,- «ia= .r:,«n.•�. �ci:tr�:c'.:,;.a.�: '„�.+eir;ai,i �rt;.,y' t Z ~ W JD UO U W= S2 LL W J U. Q NCY CY F W Z z� W W D Cf)_ 0 H_ W H C - ) W Z iii U= O Z BUILDING PERMIT INFORN"�TION 206 431 3670 .. Valuation of Project (contractor's bid price): $ 60 000 . oc;� Scope of Work (please provide detailed information): G} i?nry1.p t&lf ' , 6 Will there be new rack storage? []..Yes M.. No If "yes ", see Handout No. for requirements. Provide All Building Areas.in Square Footage Below. Addition to Type of Type of Interior Existing Construction Occupancy per Existing Remodel Structure New per UBC UBC 1a.. Floor 5 0 _ —0— — N h'1 2 .Floor. T Floor. :. :thru .:;Basernetit Accessory Structure* Attached Garage .:. Detached Garage Attached Carport Detached Carport Covered Deck. Uncovered Deck :. PLANNING DIVISION: Single - family building footprint (area f undation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, pro ide the following: Lot Area (sq ft):= Floor area of principal dwelling: Floor area for accessory dwelling: *Provide documen ation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Provided: Standard: Compact: Handicap: Will there be� change in use? F� ....Yes F� ..No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: ' ... Sprinklers []..Automatic Fire Alarm n ..None E]. Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? n ..Yes n ..No If "yes", attach list of materials and storage locations on a separate S -1/2 x 11 paper indicating quantities and Material Safety Data Sheets. \applications%pumit application (3.2003) 3/2003 Page 2 Z W tY � JU UO W� CO LL WO LLQ U � = �W Z HO Z t^ W W UC3 ON 0 1.— W H - tL O .• Z W UZ O Z Existing Building Valuation: $ MECHANICAL PERMIT INF01tMATION =206 -43:1 3670 : N : a -aJ U1fN MECHANICAL CONTRACTOR INFORMATION Company Name:_ Mailing Address: Contact Person: E -Mail Address: City Day Telephone: Fax Number: State Zip Contractor Registration Number: Expiration Date: * *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): Use: Residential: Commercial: Fuel Type Electric New .... ❑ New ... ❑ ❑ Gas .. ❑ Replacement .... ❑ Replacement .... ❑ Other: Indicate type of mechanical work being installed and the quantity below: Unit .Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <IOOK BTU Air Handling Unit >= 10,000 CFM Other Mechanical Equipment 0 -3 HP /100,000 BTU Furnace>IOOK BTU Evaporator Cooler 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan 15 -30 HP /1,000,000 BTU Suspended /Wall/Floor Mounted Heater Ventilation System 30 -50 I-IP /1,750,000 BTU Appliance Vent Hood 50+ HP /1,750,000 BTU Heat/Refrig/Cooling System Incinerator - Domestic Air Handling Unit <= 10,000 CFM Incinerator — Comm /Ind PERMIT APPLICATION NOTES - Appl>LCable to all perltnrts in th>ts`,applicahoin 0. . l Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the tilne for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDIN )t OR AUTHORIZED AGENT: Signature: ` Date ? 7 x'64 Print Name: 2,y)d,\l v'lrnv Day Telephone: Z0S - 4 PSG' - 4L 3 Mailing Address: ?�L - 3 h' �r, P?� f)f 7370 City State Zip Date Application Accepted: I Date Application Expires: Staff Initials: \applications \permit application (3.2003) 3/2003 Page 4 ���' `� rtsN`��N n*�m�arv.�warman om+. .r.r.».arN+«. ..r.+av��•vrKrnw., i ii'. �° S. Y'".= 2"- T�xt� .::S:rJt.::.:L'.:t:."`4 _.. -.. _ ... Z .� Z W qq JU UO W= H- �LL WO 9_J WQ N� = a �W Z H O W ~ W U ON OH W L H� —O • W Z U= H� O Z City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 RECEIPT Parcel No.: 2623049023 Permit Number D04-112 Address: 757 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 04/01/2004 Applicant: T- MOBILE Issue Date: Receipt No.: R04 -00391 Payment Amount: 463.94 Initials: SKS Payment Date 04/01/200411:28 AM User ID: 1165 Balance: $718.25 Payee: CSHQA TRANSACTION LIST: Type Method Description Amount ---- - - - - -- -- - - - - -- --------------------- - - - - -- ------ - - - - -- Payment Check 27681 463.94 ACCOUNT ITEM LIST: Description Account Code Current Pmts ------------------------ - - - - -- ---------- - - - - -- ------ - - - - -- PLAN CHECK - NONRES 000/345.830 463.94 Total: 463.94 9487 04/02 071.0 TO 463-94 .. Rece Printed fKx •i:H,17t�E.r�ki.4+'.h Z 1- JU UO N 0 CO) J � N L1.. WO L L CO)� =d �. W Z� H O. Z F- W j. O� (3 H W' W . LL .. Z. W U= O Z �,Y1tiV1, k� 1 f Cit y of Tukwila f f9Q9 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 RECEIPT Parcel No.: 2623049023 Permit Number D04 -112 Address: 757 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 04/01/2004 Applicant: T- MOBILE Issue Date: Receipt No.: R04 -00545 Payment Amount: 718.25 Initials: SKS Payment Date: 05/06/2004 01:12 PM User ID: 1165 Balance: $0.00 Payee: BUSH DECOR AND FIXTURE INC TRANSACTION LIST: Type Amount - - - - -- Method Description - - - - -- Payment Check 715 718.25 ACCOUNT ITEM LIST: Description Account Code Current Pmts ------------------------ - - - - -- ---------- - - - - -- ------ - - - - -- BUILDING - NONRES 000/322.100 713.75 STATE BUILDING SURCHARGE 000/386.904 4.50 Total: 718.25 Z w UO U) 0. J = C0 L w U-Q (0 =) = CI: �w z =. Z' � Zo W w �5 U� O� w LL H —0. 111 Z U co): O Z INSPECTION RECORD Retain a copy with permit INSPECTION NO. PER CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (20a 431 -3670 Projg�;_.. `� Type o Address: Date Called` _. Special Instructions: Date Wanted: a. m. Requester: J Ph n�o: b / /ir I Corrections required prior to approva9f-� Z = Z WU U CO) C0 W J :c �LL W O J U. ?. co) Cl = W Z� zO W W U O N 0 F- W U. 111 Z CO) O Z Approved per applicable codes. INSPECTION RECORD ;� Retain a copy with permit J 614 -1 INSPECTION NO. PE I O CITY OF TUKWILA BUILDING DIVISION .6300 Southcenter Blvd., #100, Tukwila, WA 98188 206)431-3670 Prpj.eet; Type of Igsp ction: Addr �5? � sc ,���►1� Date Called: Special Instructions: Date Wanted: a.m. Requester: ... -a Phone No: -.Approved per applicable codes. Corrections required prior to approval. COMMENTS: spe or: Da1 _ I el y OL .00 REINSPECTION F E REQUIRED. rior to inspection, fee must be id at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: z ~ W JU UO (1)0, Cl) LU �LL W O 9 : u_ cf)d =w I— O z 1- W W U� O �' i, f- W UJ F-- W Z tll U= O~ z INSPECTION RECORD Retain a co with p ermit r �l INSPEC ION NO. cop p PERMIT CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: • rr -- --- loll Type of Ins tion: Addre g _ 1 -• ,/ Gv � Called: SpI . C A Date Wanted: �( .m. / 0� p.m. Requester: Phone No: YOPIF/5 - 7119 ` proved per applicable codes Receipt No.: Date: I , Z �Z W J U. UO W W Co LL WO 9a N Z) = �W z� ZO LU W U O C 0 H WW H L). W Z til U= O~ Z Corrections required prior to approval. INSPECTION RECORD �� �� , _�` \3 _ Retain a copy with permit INSPECTION NO. PER NO CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (20 )431 -3670 Projeci� -- j Type of inspection: 1 , D Q Ad S G �� �L�L 7S Date Ca led: -17 ' 04� Special Instructions: Date Wanted: a. m. Requester:, Phonon: !� Approved per applicable codes. 92corrections required prior to approval. COMMENTS: Inspector Dater / v Fj $47.00 REINSPECT ON FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: :1 Z JU 00 W= J �- �LL WO L L CO = F W Z� F- O z W �5 U O co O H W LIJ HF 111 Z US O ~; Z INSPECTION RECORD Retain a copy with permit r ' l INSPECTION NO. PERMIT NO CITY OF TUKWILA BUILDING DIVISION LW 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Proje _. ' Type of Inspection: Address: Date Called: Special Instructions: Date Wanted: Requester: U h Phone No: Inspector: Date: $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Z H '~ W JU 0 ND J = CO O _ WO LLQ = CY �. W Z' H O Z I— U� O N �H W LU LL �U —O .Z W U= O Z INSPECTION RECORD Retain a copy with permit INSPECTION NO. j NQ CITY-OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (6)431 -3670 Project: Type Pfrfs ection: Addr ss: Z sd M446 Date Called: /\ :5 S ecial Instructions � Date Want�f: � � � 4'"" Requester: 1,. ' Phone o: / pproved per applicable codes. Corrections required prior to approV COMMENTS: I Inspect r/' $47. E)-REINSPEI paid at 6300 Sou Date-- - Ue :E REQUIRED. Prior to inspection, fee must e Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Z �Z �W 2 JU U0 CO J H S2 U_ W J LL co = W 1— ZH Z �. UJ 5 UC1 fn o — W W LL U H — Z llJ U =. O I— Z O 1908 Thomas P. Keefe, Fire Chief Steven M. Mullet, Mayor Permit No. OC . Retain current - inspection schedule Needs shift inspection Suite ## Approved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: 7 r Hood & Duct: —�- Halon : — Monitor: Pre -Fire: Permits: E City of Tukwila TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Fire Department Authorized Signature ~' ` FINALAPP.FRM Rev. 2/19/98 Date T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206 -575 -4404 • Fax. 206 -575 -4439 Z ~ w JD UO N J = H TLL w 9-1 LL C0 0 = a �w �O Z�_ w w D ON o F- wW �- F- U_ O W Z CO b H. O Z 2001 2001 Washington State Nonresidential Energy State Nonresidential Energy Code Compliance Form 2002- Project Info Project Address T- Mobile (Southcenter Mall) Date 3/30/2004 Area in ft Southcenter Mall Blvd. For Building Department Use RECEIVED CITY OF T1 1KWI1 A Tukwila, WA 98188 1.50 948.0 1422.0 APR 12004 Applicant Name: Bret Wilkinson, P. 1.50 PERMIT CENTER Applicant Address: 250 South 5th Street - Boise, ID 83702 Applicant Phone: (toe) 393 -9635 Project Description ❑ New Building ❑ Addition [D Alteration El Plans Included Indicate controls (Sections 1513) including commissioning requirements on plans. 0 Prescriptive p Lighting Power Allowance Q Systems Analysis ompliance Option (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box) ❑ No changes are being made to the lighting ❑ Less than 60°x6 of the fixtures are new, and installed lighting wattage is not being increased Maximum Allowed Lighting Wattage (Interior) FILF l0,00V Location (floor /room no.) Occupancy Description Allowed Watts per ft " Area in ft Allowed x Area All Retail sales 1.50 948.0 1422.0 Sales 101 Merchandise Display 1.50 608.0 912.0 101 Recessed Can Light (window display) 5 From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 2334. 0 ivo[es: 1. Use manufacturer's listed maximum input wattage. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used 2. Include exit lights unless less than 5 wafts per fixture. Proposed Lighting Wattage (Interibkyt all fixtures. For exempt lighting, not exception and leave Watts /Fixture blank. Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed 102 2x4 Recessed Troffer w /Acrylic Lens 4 62.0 248.0 101 2X2 Recessed Troffer w /Specular Louvers 10 62.0 620.0 101 Recessed Can Light (window display) 5 101 G 102 Exit sign 2 101 Track Lighting (merchandise display) 25 50.0 1250.0 103, 104 i 105 4 -ft Surface Strip Light 1 62.0 62.0 I TT .r, GM OF TUMI-14 .� Y.: • p U 27517 O ` S'Sr G 6iiY N G DN EXPIRES 01.08 -e) Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 2180.0 I .. 7k /. X SRT" 1 i 4pY2f, 4, '. ?X.?'f FPYS.'+ r%, M' s: f C' Att,< YnzHrc! Y9, O. uat�'.'. mn:... A• l' ucr» .vrnncerta >.•� ; 'ert• ".4:' `;r11: ?!x; �`f ° 'v'9: } �34f9AhK`.[1�1`l .M«f,.� Z W J U wz F _ CQ W WO LL U :) = CY W ZH HO Z W W UC3 O� W H LL O 111 Z U= O Z ' 2001 Washington State Nonresidential Energy Code Compliance Form Maximum All Lighti "Wattage (Exterior) Proposed Lighting Wattage (Exterior) the default table in the NREC Technical Reference Manual may also be used. Location Fixture Description Allowed Watts Area in ft Allowed Watts Location Description per ft or per If (or If for perimeter) x ft (or x if) Covered Parking (standard paint) Not a part 0. W /ft Covered Parking (reflective paint) Not a part 0.3 W/ft Open Parking Not a part 0.2 W /ft Outdoor Areas Not a part 0.2 W /ft Bldg. (by facade) Not a part 0.25 W /ft Bldg. (by perim) INot a part 7.5 W /If Note; for building exterior, choose either the facade area or the perimeter method, but not both) Total Allowed Watts Proposed Lighting Wattage (Exterior) the default table in the NREC Technical Reference Manual may also be used. Location Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Total Proposed Watts may not exceed Total Allowed Watts for Exterior Total Proposed Watts . .:...,:.. :,..:.'...:s_ «.,.n.�:,..._:. ,.+. tii. vu:..,.,...,. 1;...>: way..:.: s...::u�.i.e +L.;;;aS..,tie:.vn.d r:`:a:sG4'.:��••+ =1, Jar .tn..4,e�.a�:.2.�:,+ .. :. s: t: i.�ea.':t:::.:wYl:ee!,wr:u.+id' �1ik l�«3tLUit.RiY`Ciro'�i+n : alt? 1 '„�15+ %:ai::Li!.;o0 *.1�7WiF.:1: Q ~ W ' �Q CO UJI N o J = H N W. w O �Q Cl) _ CY �W F- O Z I-- Cl O CO. O H. W W Z U U — O� .. Z w O ~. z 2001 2001 Washington State Nontesldentlai Energy Code Prescrip Spaces Qualification Checklist Note: If occupancy type is "Other" and fixture answer is checked, the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans. If not qualified, do LPA Calculations. ashington State Nonresidential Energy Code Compliance Form t. ,ompllance Forms Revised June 2002 - Occupancy: O Warehouses, storage areas or aircraft storage hangers 0 Other Lighting Fixtures: ❑ Check here if at least 95% of fixtures in the space meet all four criteria: 1. Fixtures are fluorescent, non - lensed, with only one or two lamps, and 2. Lamps are T -1, T -2, T -4, T -5, T -6, T -E 3. Lamps are 5 -50 Watts, and 4. Ballasts are electronic ballasts 5. Exit lights < 5 watts /fixture 6. Screw -in compact fluoresc fix do not qualify TABLE 15 -1 Unit Lighting Power Allowance (LPA) Use LPA Wls Use LPA Is Painting, welding, carpentry, machine shops 2.3 Police and fire stations 1.5 Barber shops beauty shops 2.0 Atria atriums 1.0 Hotel banquebconference /exhi bit! on hall ' 2.0 Assembly spaces', auditoriums, gymnasia , heaters 1.0 Laboratories 2.0 Group R -1 common areas 1.0 Aircraft repair hangars 1.5 Process plants 1.0 Cafeterias, fast food establishments 1.5 Restaurantslbars 1.0 Factories workshops, handling areas 1.5 Locker and /or shower facilities 0.8 Gas stations, auto repair shops" 1.5 Warehouses", storage areas 0.5 Institutions 1.5 Aircraft storage hangars 0.4 Libraries 1.5 Retail ' retail banking 1.5 Nursing homes and hotel /motel guest rooms 1.5 Parking garages See Section 1532 Wholesale stores (pallet rack shelving) 1.5 Mall concourses 1.4 Plans Submitted for Common Areas Only Schools buildings (Group E occupancy only), school classrooms, day care centers 1.35 Main floor building lobbies (except mall concourses 1.2 Laundries 1.3 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 Office buildings, office /administrative areas in facilities of other use types (including but not limited to schools hospitals, pitals, institutions, museums, banks, churches) 1.2 Footnotes for Table 15 - 1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) Includes pump area under canopy. 7) In cases in which a lighting plan is submitted for only a portion of a floor, a Unit Lighting Power Allowance of 1.35 may be used for usable office floor area and 0.80 watts per square foot shall be used for the common areas, which may include elevator space, lobby area and rest rooms. Common areas, as herein defined do not include mall concourses. 8) For the fire engine room, the Unit Lighting Power Allowance is 1.0 watts per square foot. 9) For indoor sport tournament courts with adjacent spectator seating, the Unit Lighting Power Allowance for the court area is 2.6 watts per square foot. 10) Display window illumination installed within 2 feet of the window, lighting for free- standing display where the lighting moves with the display, and building showcase illumination where the lighting is enclosed within the showcase are exempt. An additional 1.5 w /ft of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. Z '~ W JU 0 NQ J 00 U_ WO U Q = d W Z` 3: H O Z I- 5 U� ON D f- W I=- H �- O Z W U= O� Z `�:''vw1 u,i,4na l:'t viii �y;i�Ri;'F�•a ir�ae:+ltu �1(''t$:Kd:i:x'G.�...a i'y:3.'tia.:.; •M. 2001 Washington State Nonresidential Enerav Code Comaliance Form i Lighting Permit Plae Checklist LTG-CHK 2001 Washington State Nonresidential Energy Code Compliance Forms Revised June 2002 • KJM Project Address T- Mobile (southcenter Mall) Date 3/30/2004 The following information is necessary to check a lighting permit application for compliance with the lighting requirements in the 1994 Washington State Nonresidential Energy Code. Applicability (yes, no n.a.) Code Section Component Information Required Location on Plans Building Department Notes LIGHTING. CONTROLS (Section 1513) yes 1513.1 Local control /access Schedule with type, indicate locations E -2 yes 1513.2 Area controls Maximum limit per switch E -2 a. 1513.3 Daylight zone control Schedule with type and features, indicate locations a. vertical glazing Indicate vertical glazing on plans a • overhead glazing Indicate overhead glazing on plans yes 1513.4 Display /exhib /special Indicate separate controls E -2 1513.5 Exterior shut -off Schedule with type and features, indicate location n.a. (a) timer w /backup Indicate location x.a. (b) photocell. Indicate location 1513.6 Inter. auto shut -off Indicate location a. 1513.6.1 (a) occup. sensors Schedule with type and locations a. 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans _T_ 4 1513.7 Commissioning Indicate requirements for lighting controls commissioning yes Lighting Sum. Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture E -1 r . a • Elec motor efficiency MECH -MOT or Equipment Schedule with hp, rpm, efficiency If "no ". is. circled for any. question, provide. explanation: Z Z �W QQ� JU U U co W W = H CO LL WO } J . U. Q c o = a F. W Z Z O. W W U� O� 0 t-- WW �U LL ~ O .. Z W co O� Z NYifi:adiL'FXAa:. NLY 4: <�� re.., r: /.. :�h +3a: <: :K+iic��. .�5?:t �a��Fwi�.�t;lfi�^`;ti.' W;Rrx' ��J.��•. +aa::wu'.7wis wig ✓ '' u++id� '"+ -t' 2001 Washington State Nonresidential Energy Code Compliance State Nonresidential Energy Code Compliance Forms Lighting - General Requirements 1513 Lighting Controls. Lighting, including exempt lighting in Section 1512, shall comply with this section. Where occupancy sensors are cited, they shall have the features listed in Section 1513.6.1. Where automatic time switches are cited, they shall have the features listed in Section 1513,6.2. 1513.1 Local Control and Accessibility: Each space, enclosed by walls or ceiling- height partitions, shall be provided with lighting controls located within that space. The lighting controls, whether one or more, shall be capable of turning off all lights within the space. The controls shall be readily accessible, at the point of entry/exit, to personnel occupying or using the space. EXCEPTIONS: The following lighting controls may be centralized in remote locations: 1. Lighting controls for spaces which must be used as a whole. 2. Automatic controls. 3. Controls requiring trained operators. 4. Controls for safety hazards and security. 1513.2 Area Controls: The maximum lighting power that may be controlled from a single switch or automatic control shall not exceed that which is provided by a twenty ampere circuit loaded to not more than eighty percent. A master control may j be installed provided the individual switches retain their capability to function independently. Circuit breakers may not be used as the sole means of switching. EXCEPTIONS: 1. Industrial or manufacturing process areas, as may be required for production. 2. Areas less than five percent of footprint for footprints over 100,000 square feet. 1513.3 Daylight Zone Control: All daylighted zones, as defined in Chapter 2, both under overhead glazing and adjacent to vertical glazing, shall be provided with individual controls, or daylight -or occupant- sensing automatic controls, which control the lights independent of general area lighting. Contiguous daylight zones adjacent to vertical glazing are allowed to be controlled by a single controlling device provided that they do not include zones facing more than two adjacent cardinal orientations (i.e. north, east, south, west). Daylight zones under overhead glazing more than 15 feet from the perimeter shall be controlled separately from daylight zones adjacent to vertical glazing. EXCEPTION: Daylight spaces enclosed by walls or ceiling height partitions and containing 2 or fewer light fixtures are not required to have a separate switch for general area lighting. 1513.4 Display, Exhibition, and Specialty Lighting Controls: All display, exhibition, or specialty lighting shall be controlled independently of general area lighting. Revised June 2002 - KJM 1513.5 Automatic Shut -Off Controls, Exterior: Exterior lighting not intended for 24 -hour continuous use shall be automatically switched by timer, photocell, or a combination of timer and photocell. Automatic time switches must also have program back -up capabilities, which prevent the loss of program and time settings for at least 10 hours, if power is interrupted. 1513.6 Automatic Shut -Off Controls, Interior: Office buildings greater than 5,000 sq. ft. and all school classrooms shall be equipped with separate automatic controls to shut off the lighting during unoccupied hours. Automatic controls may be an occupancy sensor, time switch, or other device capable of automatically shutting off lighting. EXCEPTIONS: 1. Areas that must be continuously illuminated, or illuminated in a manner requiring manual operation of the lighting. 2. Emergency lighting systems, 3. Switching for industrial or manufacturing process facilities as may be required for production, 1513.6.1 Occupancy Sensors: Occupancy sensors shall be capable of automatically turning off all the lights in an area, no more than 30 minutes after the area has been vacated. 1513.6.2 Automatic Time Switches: Automatic time switches shall have a minimum 7 day clock and be capable of being set for 7 different day types per week and incorporate an automatic holiday "shut -off' feature, which turns off all loads for at least 24 hours and then resumes normally scheduled operations. Automatic time switches shall also have program back -up capabilities, which prevent the loss of program and time settings for at least 10 hours, if power is interrupted. Automatic time switches shall incorporate an over -ride switching device which: a) is readily accessible; b) is located so that a person using the device can see the lights or the areas controlled by the switch, or so that the area being illuminated is annunciated; and c) is manually operated; d) allows the lighting to remain on for no more than two hours when an over -ride is initiated; and e) controls an area not exceeding 5,000 square feet or 5 percent of footprint for footprints over 100,000 square feet, whichever is greater. 1513.7 Commissioning Requirements: For lighting controls which include daylight or occupant sensing automatic controls, automatic shut -off controls, occupancy sensors, or automatic time switches, the lighting controls shall be tested to ensure that control devices, components, equipment and systems are calibrated, adjusted and operate in accordance with approved plans and specifications. Sequences of operation shall be functionally tested to ensure they operate in accordance with approved plans and specifications. A complete report of test procedures and results shall be prepared and filed with the owner, Drawing notes shall require commissioning in accordance with this paragraph. Z ~ W _3 L) UO W= I— �W WO LL N = ut F H O W ~ W UCl O- i0 H W H� U. O .. Z W U= O Z PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D04 -112 DATE: 04 -01 -04 PROJECT NAME: T- MOBILE SITE ADDRESS: 757 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter #_ Revision # afteribefore permit is issued DEPARTMENTS: ,per Buil " Division Public Works i , r L * 1 51 2- W c 4- - i�-Ocf Fire Prevention Structural ❑ oj(, P& Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS (Tues., Thurs.) Complete Ed Incomplete ❑ Comments: DUE DATE: 04 -06 -04 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TOES /THURS ROUTING: Please Route 9 Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS Approved ❑ Approved with Conditions [V Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: PERMIT COORD COPY Documents /routing slip.doc 2 -28.02 l::::.A .4. z i,s i ��f a e' ; *, "•�.!'.S<s >.. *ri„e „ <.J:: �5++.,z v.�.1,a-wti1 >� :•'i. z .�:�. DUE DATE: 05 -04 -04 Not Approved (attach comments) ❑ z ~ w JU UO 0 Ito W J = CO U _ w 9-1 U� cod = w F- Z~ F_ O z I_ w W U� Ito o�_ wW HP LL O ..Z W CO O Z dEPARTMENT• - OF L ABOR AND INDUSTRIES• • . State of Washington DEPARTMENT OF LABOR & INDUSTRIES PO BOX 44450 OLYMPIA WA 98504 -4450 BUSH DECOR & FIXTURE INC 3949 W YORKSHIRE DR SOUTH JORDAN UT 84095 FIRST CLASS MATE. V$ POSTAGP,, PAID OLVMPTA WA PERMIT NO 11 z r-- Detach And Display Certificate -� Detach And Display rertificee ' REGISTERED AS PROVIDED BY LAW ASI CONST ;..:.. . DATE CCOT " "'BUSHDF2005•UR 01/ EFFECTIVE D.�TE 06/19/.2000 BUSH DEC OR. ° &`' FTX,TURE. tNC ' 3949 W YORKSHIRE DR SOUTH J .095 Signetucc Issu y EPARTIAENT O _ OR ANA INDUSTRIES J F625.0524W W971 Please Remove And Sign Identification Card Before Placing In Billfold '.r SUMMARY AP I_ICAf3I E COL)[ 1996 UNIT OPV CODE WITH WA`)HINGTON AMENDME_N TS 1 996 UNI{ 0PM 1 1 { C; IPIC CODE WI 1 H WASHINGTON AML IJDME N TS 1906 UNIT OPR A rAf CHAr ,IICAI COf)f WITH WASHING ION AML NDMENTS 19 96 UNIT ORM I'1 UMHINC CODE WITH WASHINGI ON AMENDMENTS WASHINGT()N `)TAT[ f NI RGY CODE OCCUPANCY GROUP M (MFRCANTILF) TYPE 01 CONSTRUCTION V--N FIR[ PROTECTION: (E) FULLY SPRINKLERED ACTUAL TENANT AREA 945 S.F AREA & OCCUPANT LOADING SALES: BACKROOM INVENTORY /STOCKROOM 608.0 S.I. / 30 253.0 S.F. 100 84.0 S.F. 300 20.26 0CC. 2.53 OCC. .28 OCC. TOTAL OCCUPANCY 945 S.F. 23.07 OCC. 2 EMERGENCY EXITS PROVIDED ACST EAST EXIT WIDTH REQUIRED (SALES AREA) INFORMATION SALES: 20.26 OCC. x 0.2 IN. = 4.05 IN. INVENTORY /OFFICE 2 53 OCC. x 0.2 IN. = .56 IN TOTAL 60.90 OCC. x 0.2 IN. = 4.61 IN. TOTAL EXIT WIDTH PROVIDED 98 IN (DOOR EX Q 8' -2" WIDE) GENERAL CONDITIONS 1 ALL WORK AND MATERIALS SHALL BE INSTALLED IN ACCORDANCE WITH ALL CODES HAVING JURISDICTION. 2 ALL WORK SHALL BE PERFORMED IN CONFORMANCE WITH THE BUILDING MANAGEMENT'S RULES AND REGULATIONS. 3_ MODIFICATIONS TO THE BASE BUILDING STRUCTURE, CORE AREAS AND UTILITY SYSTEMS ARF NOT IN THIS CONTRACT, EXCEPT AS NOTED ON THESE DRAWINGS OR AS REQUIRED TO COMPLETE THE WORK INDICATED ON THESE DRAWINGS. 4 THE CONTRACTOR SHALL MAKE ALL ARRANGEMENTS AND PAY FOR ALL FEES, CHARGES AND PERMITS REQUIRED AS WELL AS FOR HAULING, RIGGING AND TRANSPORTATION CHARGES. �• PENETRATIONS THROUGH FIRE -RATED ASSEMBLIES SHALL BE FIRE STOPPED PER PER APPLICABLE CODE). 6. ALL. INSULATION MATERIALS, INCLUDING FACINGS, SUCH AS VAPOR BARRIERS OR BREATHER PAPERS INSTALLED WITH FLOOR- CEILING ASSEMBLIES, ROOF- CEILING ASSEMBLIES, WALLS, CRAWL SPACES, OR ATTICS SHALL HAVE A FLAME - SPREAD RATING PER APPLICABLE CODES. 7. CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS. CONTRACTOR SHALL PROVIDE MATERIAL AND INSTALL ALL SYSTEMS AS REQUIRED BY THESE DOCUMENTS AND APPLICABLE CODES. 8. EXECUTION OF THE CONTRACT BY CONTRACTOR IS A REPRESENTATION THAT THE CONTRACTOR HAS VISITED THE SITE AND HAS BECOME FAMILIAR WITH THE LOCAL CONDITIONS UNDER WHICH THE WORK IS TO BE PERFORMED, THE CONTRACTOR SHALL. VERIFY ALL EXISTING CONDITIONS BEFORE COMMENCING WORK AND SHALL NOTIFY ARCHITFC ; HD /OR ENGINEER IF A CONDITION EXISTS WHICH PREVENTS THE CONTRACTOR FROM ACCOMPLISHING THE INTENT OF THE DRAWINGS. 9. EXISTING FIRE SPRINKLER SYSTEM TO REMAIN. THE FIRE SPRINKLER SUBCONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR SPRINKLER HEAD RELOCATION /MODIFICATIONS TO THE AUTHORITY HAVING JURISDICTION FOR REVIEW AND APPROVAL PRIOR TO BEGINNING WORK. FIRE SPRINKLER SUBCONTRACTOR TO OBTAIN ALL REQUIRED PERMITS. KEY PLAN T LAf%M11 C a CSHQA 250 S. 5TH ST. BOISE, ID. 83702 CONTACT: SANDY IRVINE PH: (208) 429 - 4037 FAX: (208) 343 -4638 TENANT IMPROVEMENT SOUTHC NT R MALL 1127 SOUTHCENT R MALL BLVD., SPACE 252 TUKWILA, WASHINGTON 98188 TENANT: T- MOBILE LANDLORD: WESTFIELD SHOPPINGTOWN 5242 SOUTH COLLEGE DRIVE 11601 WILSHIRE BLVD. SUITE 1200 SUITE 170 LOS ANGELES, CA 90025 SALT LAKE CITY, UT 84123 JOSE HERNANDEZ CONTACT: MATT CHILD (310) 575 -5918 PH: (801) 860 -1178 ARCHITECT: CSHQA GENERAL TO BE DETERMINED 250 S. 5TH ST. CONTRACTOR: BOISE, ID. 83702 CONTACT: SANDY IRVINE PH: (208) 429 -4037 FAX: (208) 343 -4638 MECHANICAL, ELECTRICAL & PLUMBING ENGINEER: I I FI LE COPY -- I I understand that the Plan Check approvals are subject to e rrors and omissions and approval of plans does not authorize the violation of any adopted code or ordinance. Receipt of con- tractor's copy of approved plans acknowledged, Dates Permit No. SEPARgT E M REQUIRED FOR: 116 ECHgNICAL ELECTRICAL PLUMBIHO NA 3AS PIPING CITY OF 'ryUKMu 811ILDING DMgIIpN , �EVa�' NO _nom E &. i dd. AM 0" - SYMBOLS Elevation Number A ELEVATION Sheet Where Drawn DETAIL Elevation Number T 6 Sheet Where Drown Elevation Number A SECTIONS Sheet Where Drown ROOM NUMBER 0410 DOOR Door number - A 1 Hardware set 7 EQUIPMENT TYPV 0 RF VISION Ai\ FLOOR SURFACES nP T FINISH TYPE P ALIGN FINISH SURF ACES AL IGN (lAS( SURF ACE L PI A' TI(" I AMIN A TE Ci5 2 ABBREVIATIONS ABOVE FINISHED FLOOR AFF EACH EA INCH IN ACOUSTIC ACST EAST E INFORMATION INFO ADJUSTABLE ADJ ELECTRIC, ELECTRICAL ELEC INSIDE DIAMETER ID AIR CONDITIONING A/C ELEVATION EL INSULATED, INSULATION INSUL AIR HANDLING AH ELEVATOR ELEV INTERIOR INT AIR HANDLING UNIT AHU EMERGENCY POWER EM UNDERWRITER LABORATORY UL ALTERNATE ALT EMPTY CONDUIT EC JANITOR'S CLOSET JC ALTERNATE CURRENT AC ENGINEER ENGR JOINT JT ALUMINUM AL ELECTRIC WATER COOLER EWC JOIST JST AMPERES AMP ELECTRIC WATER HEATER EWH JUNCTION BOX JB ANCHOR BOLT AB EXHAUST EXH RADIUS PAD. R ARCHITECT ARCH EXISTING EXIST. LAMINATED LAM AT 0 EXPANSION EXP LAVATORY LAV AVERAGE AV EXPANSION JOINT EXP JT LEFT HAND LH RETURN AIR RA EXTERIOR E X T LENGTH L BEAM BM EQUAL EQUAL LIBRARY LIB BOARD BD LINEAR FEET LF FAHRENHEIT F LONG LEG HORIZONTAL LLH CABINET CAB FEET PER MINUTE FPM LONG LEG VERTICAL LLV CATALOG CAT FEET, FOOT FT CEILING CLG FINISH FIN MAINTENANCE MAIN T CENTERLINE CL FIRE EXTINGUISHER CAB_ FEC MANUFACTURER MFR CERAMIC TILE CT FLOOR FL MASONRY MAS CLOSET CLO FLUORESCENT FLUOR MASONRY OPENING MO COLUMN COL FIRE RATED FR MAXIMUM MAX COMPANY CO STORAGE STOP MECHANICAL MECH CONCRE TE CONC GAUGE GA MEDIUM MED CONCRETE MASONRY UNITS CMU GALLON GAL MEZZANINE MEZZ CONFERENCE CONE GALLONS PER MINUTE GPM MINIMUM MIN CONTINUOUS CONT GALVANIZED GAL V MISCELLANEOUS MISC CONTROL JOINT CJ GENERAL CONTRACTOR GC MOUNTED MTD COORDINATE COORD GROUNDED FAULT !NTFRAUPT GPI MULLION MUL CORRIDOR CORK GYPSUM GYP ME_ T AL M Tl CUBIC FEET CF GYPSUM WAL BOARD GWR CUBIC FFE T PER MINUTE CF M NO T IN CONTRACT NIC HANDICAPPED HE CF' NOT TO SCAT F NTS DE RICA TED DF -D HARDWARE HPW NUMPF R #. NO DEPARTMENT DEPT HARDWOOD HG WV NOT APPLICAPLE N/A DEPTH D HEIGHT HG 1, r4 DE TAIL DE T HE RTZ HZ DI AGON AL DI AG HOL LOW ME T Al HM OFF ICF OFF DIAME TFR DIA H0R110NTAt HORIZ ON CFNTFR OC PIMFNSION DIM H ORS[ P0WE R HP OPE NINC OPNG DISHWA R DW HOT WA TFR HF A TF R HWH O PPOSI TE O p p DOOR DR H;')(jp HR OUNCE OZ D0WN DN OVERALL_ C,A DRAWING DWG OVERHF AD OH • • BUILDING CITY OF TUKWILA DEPARTMENT COMMUNITY DEVELOPMENT DEPARTMENT PUBLIC WORKS DEPARTMENT, PERMIT CENTER 6300 SOUTHCENTER BLVD., SUITE 100 TUKWILA, WASHINGTON 98188 PAINTED PTD TELEPHONE TEL PANEL PNL THICK OR THICKNESS THK PARTITION PTN THRESHOLD THRSLD PERPENDICULAR PERP TILE T PERSONAL COMPUTER PC TONGUE & GROOVE T &G PHASE PH TOP T PLASTIC LAMINATE P LAM TYPICAL TYP PLATE PL SALES ELEVATIONS PLUMBING PLMB UNDERWRITER LABORATORY UL PLYWOOD PLYWD POLYVINYL CHLORIDE PVC VERTICAL VERT PREFABRICATED PREFAB VESTIBULE VEST PREFINISHED PREFIN VINYL COMPOSITION TILE VC T PRELIMINARY PRELIM VOLTS V QUARRY TILE QT WALLBOARD VV8 WELDED WIRE FABRIC WWF RADIUS PAD. R WIDTH W REFRIGERATOR PEF WINDOW VD REINFORCING PEINF WI TH WV/W REQUIRED PLOD WI THOU T W /0 RESILIENT RES WOOD WD RETURN AIR RA RIGHT HAND PH YARD YD ROOM RM ROUGH OPENING PO SCHEDULE SCHED SECTION SECT SERVICE SINK SS SIMI( AR Sim SOUND TRANSMISSION STV SPECIFICATION SPE C SPECIFIED SPECD SQUARE SQ STANDARD STD STANDARD PIPE Sr STAINLESS STFFt SS STATION STA STEFL STL STORAGE STOP STRUC TURAI STR",C T SUSPENDED CE It INC, SUSP DRAWING INDEX 6RCHI A - -o Cove S1 -iF_F_1 A GENE' ^AL NOTES A -- 2 I~ Loon PLAN A - 2.1 SECTIONS DFIAILS A. -- 2.2 DEMOLI PLAN A--3 REFLECTED CEILING PLAN A -4 FIXTURE & FLOOR FINISH PLAN A-5 DETAILS AND NOTES A--6 SALES ELEVATIONS A— DETAILS ENGINEERING E---1 SYMBOLS, PANELS NOTES E - 2 LIGHTING PLAN E--3 POWER PLAN E -4 TITLE 24 DEFERRED SUBMITTALS FIRE SPRINKLER MODIFICATIONS SIGN PERMIT CIV OF JOKV10 APPROVED APR 2 Z04� p k " i tU VICINITY MAP T - MOBILE 1127 SOUTHCFN-ER MALL BLVD. _ lV i - ' 1 AS $t �� i � i Ce e llr» Ile- ` -- •-- - . .� �� _ . I � 1. � 0o a ir�a t 1 ` �Ip er Blvd iI Paik i r ti S 1CCth a' - _' ftoft ' r' -,:; - - -----I 4 tT2n d DI MiOder Blvd N �'JV ? .31t , ,t ran, st . `' , 9 180th 3t -wio " .. s 1 t h St I� tot i S 2 The 12 r owl .1 Z ISE eG�l� F€ 5 JL V � N N 0 �a Q a Z F � I �T PR DATE 04072.000 01/01/04 LAY S, R£J'SE� I I CITY OF TL4C*XA APR - 1 2MK m 5►+EE' ' ', E OHM A�o i s 14 A. GENERAL REQUIREMENTS I. BASIC PROVISIONS A THE STATEMENTS BELOW APPLY THROUGHOUT ALL OF THE CONTRACT DOCUMENTS TO ALL CONTRACTORS, SUBCONTRACTORS SUPPLIERS, OWNER - BUILDERS AND OTHERS WHO MAY USE THESE DRA WINGS DURING THE LIFE OF THIS PROJECT. THE TERM "CONTRACTOR" WHERE IT APPEARS BELOW AND THROUGHOUT THE CONTRACT DOCUMENTS DESCRIBES ALL OF THESE PARTIES. B. IF WRITTEN SPECIFICATIONS ACCOMPANY THESE DRAWINGS ITEMS REQUIRED BY EITHER SHALL BE CONSIDERED TO BE REQUIRED BY BOTH, CONFLICTS BETWEEN THE TWO SHALL BE GOVERNED BY THE SPECIFICATIONS. C. THE DRAWINGS AND SPECIFICATIONS MAY NOT CONTAIN ALL ITEMS THAT ARE NECESSARY FOR A COMPLETE AND FUNCTIONAL PROJECT. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO FURNISH AND INSTALL ANY ITEM WHICH MAY BE REASONABLY INFERRED AS BEING REQUIRED TO ACCOMPLISH A FINISHED PRODUCT. D. THE CONTRACTOR IS RESPONSIBLE FOR HAVING A REASONABLE KNOWLEDGE OF ALL CODES, LAWS, STANDARDS, ACCEPTED METHODS AND PERFORMANCE CRITERIA APPLICABLE TO THE PROJECT. ALL MATERIALS AND EQUIPMENT SHALL BE INSTALLED IN A WORKMANLIKE MANNER, AND IN ACCORDANCE WITH STANDARD PROCEDURES RECOMMENDED BY THE MANUFACTURERS, TRADE ASSOCIATIONS, OR OTHER GENERALLY RECOGNIZED CONSTRUCTION STANDARDS ORGANIZATIONS. WORK SHALL CONFORM TO ALL APPLICABLE CODES, LAWS, STANDARDS, AND REGULATIONS OF GOVERNING AUTHORITIES. E. THESE DOCUMENTS HAVE NOT BEEN PREPARED UNDER A FULL SERVICES ARCHITECTURAL AGREEMENT AND ARE NOT WARRANTED BEYOND A CUSTOMARY DILIGENCE. IF ANY OMISSION OR DISCREPANCY 15 FOUND WITHIN OR BETWEEN THE CONTRACT DOCUMENTS, OR IF ANY FEATURE SHOWN CONFLICTS WITH ANY LAW, CODE, STANDARD PRACTICE, PERFORMANCE CRITERIA, OR ANY MANUFACTURER OR TRADESMAN WARRANTY, THE OWNER SHALL BE NOTIF PROMPTLY 50 THAT THE ITEM IN QUESTION CAN BE RESOLVED PRIOR TO CONSTRUCTION INVOLVING THE ITEM. FAILURE TO NOTIFY THE OWNER OF A REASONABLY OBSERVABLE OMISSION, DEFECT, DISCREPANCY, OR CONFLICT SHALL TRANSFER TO THE CONTRACTOR ALL RESPONSIBILITY FOR ANY CONSEQUENCES OF SUCH FAILURE TO NOTIFY. F. ALL ACTIONS TAKEN WITHOUT SPECIFIC DIRECTIVES STATED IN THE DOCUMENTS SHALL BE THE RESPONSIBILITY OF TH05E TAKING SUCH ACTIONS. G. T CONTRACTOR SHALL VISIT THE SITE TO BECOME FAMILIAR WITH EXISTING CONDITIONS BEFORE CONSTRUCTION BEGINS. ALL REASONABLY OBSERVABLE CONDITIONS SHALL BE ACCOMMODATED BY THE CONTRACTOR AFTER WORK HAS BEGUN. H. SECURE ALL NECESSARY PERMITS AND LICENSES. 2. CLEANING A. THE CONTRACTOR AND SUBCONTRACTOR SHALL AT ALL TIMES KEEP THE JOB FREE FROM EXCESSIVE ACCUMULATION50F WAST MATERIALS AND RUBBISH. 3. WARRANTIES A. THE CONTRACTOR SHALL WARRENT LABOR, MATERIALS, AND INSTALLED EQUIPMENT FOR A PERIOD OF ONE YEAR FOLLOWING THE DATE OF OCCUPANCY BY THE OWNER OR THE DATE OF FINAL PAYMENT, WHICHEVER OCCURS FIRST. THE CONTRACTOR SHALL REPAIR AT NO COST TO THE OWNER ANY FAILURE OR DEFICIENCY DISCOVERED WITHIN THIS TIME PERIOD. B_ COPIES OF WARRANTIES FOR SPECIFIC ITEMS SHALL BE DELIVERED TO THE OWNER PRIOR TO FINAL PAYMENT. 4. ALL WORK SHALL CONFORM TO THE REQUIRMENTS OF ALL CODES AND REGULATIONS OF ALL GOVERMENTAL AUTHORITIES HAVING JURISDICTION. SUCH CODES AND REGULATIONS SHALL HAVE PRECEDENCE OVER THAT WHICH IS INDICATED ON THE CONSTRUCTION DOCUMENTS_ IN CASES OF DISCREPANCIES, OMISSIONS, CHANGES IN THE CODES OR CODE INTERPRETATIONS BY THE CODE OFFICIALS WHICH WILL CAUSE A CHANGE IN THE WORK NOTIFY INTERPLAN PRIOR TO PROCEEDING WITH THAT PROTION OF THE WORKAFFECTED BY THE CHANGE. B. THERMAL AND MOISTURE PROTECTION 1. SEALANTS A. CAULKING: -- POLYURETHANE BASED OR "SILICONIZED" ACRYLIC ELASTOMERIC, PAINTABLE. APPL AT LOCATIONS SHOWN AND WHEREVER NECESSARY TO FILL GAPS THAT COULD NOT BE SEALED BY PAINTING ALONE. B. SEALANT -- SILICONE BASE, CLEAR OR COLORED TO MATCH ADJACENT MATERIALS_ APPLY SEALANT TO SHEET METAL, GLASS OR OTHER APPLICATIONS WHERE PAINTING 15 NEITHER REQUIRED NOR DESIRABLE_ SEALANT COLOR SHALL MATCH OR BLEND WITH ADJACENT MATERIAL COLOR. C. DOORS AND WINDOWS I. DOORS A. INTERIOR SUITE DOORS -- 1 -3/4 ", SOLID CORE, HARDBOARD FACES(PAINT). B. FRAMES -- KNOCK -DOWN STEEL, "TIMELY" OR EQUAL. C. NEW OR REPLACEMENT DOORS TO EXIT CORRIDOR - MATCH BUILDING STANDARD. 2. HARDWARE A. DOOR HARDWARE - SEE SHEET A -5 3. GLAZING A. ALL GLASS SHALL BE INSTALLED WITH MANUFACTURER'S LABELS INTACT, NOT TO BE REMOVED UNTIL FINAL CLEANUP. ALL INSULATING UNITS SHALL BE WARRANTED AGAINST EDGE SEAL FAILURE. CONTRACTOR SHALL BE RESPONSIBLE FOR REPLACING BROKEN AND DAMAGED GLASS, AT NO COST TO OWNER, UP TO FINAL ACCEPTANCE. UPON COMPLETION OF ALL CONSTRUCTION, LABELS SHALL BE REMOVED AND GLASS SHALL BE WASHED CLEAN. B. MATERIALS- GL 1 - FROSTED GLASS GL2 - TEMPERED C=LASS, GAUGE SPECIFIC TO DETAIL D. MILLWORK NOTES: I. ALL MILLWORK, STANDING AND RUNNING TRIM, CASEWORK AND PLASTIC LAMINATE WORK SHALL CONFORM TO THE ARCHITECTURAL WOODWORK INSTITUTE (AWI) QUALITY STANDARD "CUSTOM GRADE" UNLESS OTHERWISE NOTED. 2. ALL MILLWORK AND FINISH CARPENTRY FABRICATION SHALL BE FABR ICATED FROM FIELD MEASUREMENTS WITH PROVISIONS FOR SCRIBING AS REQUIRED TO MEET FIELD CONDITIONS. 3. INSTALL ALL CASEWORK AND FINISH CARPENTRY PLUMB, LEVEL, TRUE AND STRAIGHT WITH NO DISTORTIONS OR WARPS. 4_ ADJUST CABINETWORK AND HARDWARE 50 THAT DOORS AND DRAWERS OPERATE SMOOTHL WITHOUT WARP OR BIND, LUBRICATE OPERATING HARDWARE AS RECOMMENDED BY HARDWARE MANUFACTURER, 5. PROTECT INSTALLED CASEWORK AND PANELWORK IMMEDIATELY AFTER INSTALLATION AGAINST SOILING AND DAMAGE. REMOVE PROTECTION JUST PRIOR TO TENANT ACCEPTANCE AND MOVE -IN AND GLEAN ALL SURFACES. b. ALL DOORS AND DRAWER FACES SHALL BE ADJUS AND ALIGNED PR IOR TO TENANT ACCEPTANCE. 1, UNLESS OTHERWISE NOTED, CONCEALED HINGES SHALL BE USED THROUGHOUT. 8 BALL- BEARING GLIDES SHALL BE USED THROUGHOUT UNLESS OTHERWISE NOTED. BOX DRAWER GLIDES SHALL HAVE A 15 RATING. FILES DRAWER GLIDES SHALL HAVE A 150 RATING. S, PROVIDE AND INSTALL GROMM IN ALL MILLWORK AT SURFACES WITH WALL - M OUNTED CONNECTIONS BELOW, FIELD COORDINATE SIZE OF GRO AND LOCATIONS WITH ARCHITECT. 10 VERIFY IN F IELD ALL DI PRIOR TO ORDERING PREFABRICATED CABINET WIDTH OF CABINETS MAY BE INCREASED /DECREASED TO NEXT STANDARD SIZE AS REQUIRED. MILLWORK NOTES: II_ METER HOLLOW CHROME ROD WITH FLANGE ENDS BY STANLEY OR EQUAL, 12. SHELVING - (5) 34" x 12"D ADJUSTABLE SHELVES WITH HARDWOOD EDGE (PAINTED) ON KNAPP 4 vOGT 85/185 STANDARDS. BOTTOr► SHELF STARTS AT I' -3" AFFt REMAINING SHELvES SPACED 12" CLEAR BETWEEN r E I CsY P WALL A. INTERIOR WALLBOARD (EXCEPT WET AREAS) -- 5i8" REGULAR GYPSUM BOARD. B. WET AREAS (TOILET, COFFEE BAR) -- 5 /15" MOISTURE RES ISTANT GYPSUM BOARD. C. FIRE SEPARATION WALLS -- 5/8" TYPE "x" G Y P S U M BOARD. D. WALLS TO RECEIVE CERAMIC TILE -- TILE BACKER BOARD, 5/8" DENS- SHIELD (GP GYPSUM) E. ALL GYPSUM BOARD SHALL BE FASTENED BY SCREWS. JOINTS SHALL BE CONCEALED WITH 3 STEP SYSTE INCLUDING EMBEDDING TAPE, MUDDING OVER TAPE, FINISH MUD AND SANDING. FINISHED SURFACES SHALL BE SMOOTH, EVEN AND UNINTERRUPTED, WITHOUT ANY TAPE SHOWING, FREE OF WAVINESS, JOINT LINES AND IMPERFECTIONS OF ANY SORTt READY FOR PAINT OR WALL COVERINGS. 2. TILE A. USE TILE COUNCIL OF AMER ICA INSTALLATION METHODS APPROPRIATE TO LOCATION. °vURFACEB TO RECEIVE TILE SHALL BE EXAMINED BEFORE TILE 15 APPLIED AND CORRECTIONS MADE TO UNSATISFACTORY CONDITIONS. 13. TOILET -- SHEET VINYL.. 3_ CARPETING A. PROVIDE ALL PAD, TACK STRIPS, ADHESIVES, TRANSITION STRIPS AND OTHER ACCESSORIES REQUIRED FOR INSTALLATION. REVIEW SEAM PATTERN WITH OWNER PRIOR TO CUTTING OR LAYING CRPET. B. CARPET SUPPLIED THROUGH OWNER'S NATIONAL ACCOUNT AT MIDW OFFICE. CONTACT: GORDON TODD OR CINDI CUNDIFF 801- 359 - 1681 4. PAINTING A. ALL SURFACES SHALL BE CLEAN AND DRY BEFORE STARTING WORK. PROTECT ALL ADJACENT SURFACES AND MATERIALS WITH COVERS, DROP CLOTHS OR MASKING, REMOVE HARDWARE, FIXTURE PLATES, COVERS, ETC. BEFORE PAINTING: AND REPLACE AFTER PAINT HAS DRIED. B. PREPARE GYP BOARD SURFACES BY DUSTING SURFACE AND REMOVING SPECKS OF COMPOUND. SAND OR REPAIR ANY IMPERFECTIONS THAT WOULD SHOW THROUGH THE PAINT. C. PREPARE METAL SURFACES BY CLEANING WITH DEGREASER. GRIND OR SAND MINOR IMPERFECTIONS. I. REGULAR GYPSUM BOARD - - WALLBOARD PRIMER PLUS ONE COAT (OR TO COVER) EGGSHELL FINISH LATEX. 2. METAL -- FACTORY PRIMER PLUS TWO COATS SEMI GLOSS LATEX ENAMEL. 3. INTERIOR WOOD DOORS -- OIL BASE PRIMER PLUS TWO COATS SEMI GLOSS LATEX ENAMEL. F. FINISH NOTES: 1. PROVIDE, STORE AND INSTALL ALL SPECIFIED FINISH MATERIALS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS. 2. NO SUBSTITUTIONS OF SPECIFIED FINISH MATERIALS WILL BE ALLOWED WITHOUT PRIOR WRITTEN APPROVAL OF INTERPLAN INCORPORATED. 3. ALL FINISH MATERIALS AND FINISH ASSEMBLIES SHALL CONFORM TO THE REQUIREMENTS OF ALL CODES AND REGULATIONS OF ALL GOVERNMENTAL AUTHORITIES HAVING JURISDICTION. ALL FINISHES MUST HAVE A FLAME SPREAD RATING OF 200 OR LESS, AND A SMOKE GENERATION RATING OF 4 OR LESS AS DETERMINED BY ASTM E 84. 4. ALL FINISH MATERIALS SHALL BE NEW, FIRST QUALITY MATERIALS NORMALLY AVAILABLE FROM THE MANUFACTURER. 5. PREPARE ALL SURFACES SCHEDULED TO RECEIVE NEW FINISHES IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS. 6. FLASH PATCH ALL AREAS WHERE FLOOR SURFACES ARE NOT SMOOTH, LEVEL OR TRUE, PRIOR TO FINISH FLOOR INSTALLATION. 1. ALL FINISH FLOOR TRANSITIONS SHALL OCCUR AT THE CENTERLINE OF DOORS OR CASED OPENINGS, UNLESS OTHERWISE NOTED. S. ALL SEAMS AND JOINTS OF FINISH MATERIALS SHALL BE STRAIGHT, SMOOTH AND CLEAN. 9. ALL SURFACES SCHEDULED TO RECEIVE PAINTED FINISHES SHALL RECEIVE ONE (1) PRIMER COAT AND TWO (2) FINISH COATS, UNLESS OTHERWISE NOTED. 10. ALL WALLS, COLUMNS AND OTHER GYPSUM WALLBOARD SURFACES SCHEDULED FOR PAINT FINISH SHALL BE FINISHED WITH LATEX FLAT ENAMEL, UNLESS OTHERWISE NOTED. ALL PAINT GRADE DOOR CASINGS, PAINT GRADE TRIMS, SHELVING, ETC. SCHEDULED FOR PAINT FINISH SHALL BE FINISHED WITH LATEX SEMI -GLOSS ENAMEL, UNLESS OTHERWISE NOTED. 11. UNLESS NOTED OTHERWISE, ALL WALL /CEILING PAINT TO BE SMOOTH ROLLED FINISH. 12. ONLY WHERE INDICATED "EQUAL TO" CR "SUBSTITUTIONS" FOR SPECIFIED MATERIALS, OR FOR LONG LEAD TIME CONSIDERATION SHALL SUBSTITUTIONS BE CONSIDERED BY INTERPLAN INCORPORATED. 13. BEFORE PROCEEDING WITH PROCUREMENT, THE RESPECTIVE INSTALLER SHALL FIELD VERIFY DIMENSIONS TO ASSURE SUFFICIENT QUANTITIES OF MATERIALS TO COMPLETE THE WORK. 14. ALL WALLS AND 5URFACE5 RECEIVING PAINT AND WALL COVERINGS, ETC. SHALL BE PROPERLY PREPARED PRIOR TO FINISH INSTALLATION AS PER MANUFACTURER'S SPECIFICATIONS. ALL J BEADS OR OTHER GYPSU METAL TRIM SHALL BE SPACKLED AND BLENDED INTO ADJACENT SURFACE. 15. COMPLIANCE WITH THE MANUFACTURER'S REQUIREMENTS FOR HANDLING, STORAGE, INSTALLATION AND PROTECTION 15 THE EXCLUSIVE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND HIS RESPECTIVE INSTALLERS ( I.E., FABRIC WALLCOVERING BACKING). 16. THE RESPECTIVE INSTALLER SHALL ADV15E ARCHITECT OF LOCATIONS OF CHANGES IN DYE LOTS, BATCHES OR SIMILAR COLOR SHIFTS. 1 THE GENERAL CONTRACTOR SHALL PROVIDE ONE FINAL TOUCHUP OF PAINTED SURFACES AFTER THE TENANT HAS MOVED INTO THE SPACE. 18. EXTERIORS OF STANDPIPE CABINETS AND FIRE EXTINGUISHER CABINETS SHALL BE PAINTED IN SEMI TO MATCH ADJACENT WALL_ 19_ ALL CEILING REGISTERS, VENTS, GRILLES, DIFFUSERS, SPEAKERS, ETC. SHALL BE PAINTED IF REQUIRED TO MATCH CEILING. 20. FINISHES CALLED FOR SHALL EXTEND OVER, UNDER AND /OR BEHIND ANY ITEM OF BUILT -IN MILLWORK, EQUIPMENT, MIRRORS, ETC. AS INDICATED ON THE DRAWINGS. M (I _ OWER AND _ _TELEPHONE NOTES: I. SEE ELEV ATIONS FOR EXACT OUTLET LOCATIONS WHERE APPLICABLE. 2. PROVIDE AND INSTALL 2 - GANG BACK BOX WITH I -GANG TRir"M RING AND DRAG LINE TO CE ILING AT TELEPHONE AND DATA LOCATIONS. PRO ✓IDE 3 '4' EMT TO CEILING AT INSULATED WALLS UNLESS OTHERW NOTED. 3. REVIEW ALL ROUGHED IN BOXES IN FIELD WITH GENERAL CONTRACTOR PRIOR TO INSTALLATION OF GYPSUM BOARD, 4. ALL TYPICAL RECEPTACLE MOUNTING HEIGHTS SHALL BE 18" AFF UNLESS OTHERWISE NOTED. 5. CONTRACTOR, TO RE VIEW DRA WINGS AND VERIFY INTENT WITH ARCHITECT, NOTIFY ARCHITECT OF ANY DISCREPANCIES AND ERRORS OR OMISSIONS PRIOR TO PROCEEDING WITH FABRICATION OR INSTALLATION. 6. REFER TO ELECTRICAL ENGINEER'S DRAWINGS FOR SWITCHING LISTS OF DEVICES AND SPECIFICATIONS RELATING TO SPECIFIED EQUIPMENT. 1. REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS, SCHEDULES AND FIXTU TYPES. 8. GANG OUTLETS AND SWITCHES WHERE POSSIBLEt GANGED OUTLETS AND SWITCHES SHALL BE INSTALLED WITH A COMMON FACEPLATE. 9. GENERAL CONTRACTOR TO VERIFY ALL CORE DRILLS PRIOR TO DRILLING. 10. COORDINATE ALL THERMOSTAT LOCATIONS WITH GENERAL CONTRACTOR PRIOR TO INSTALLATION. 11. REFER TO ELEVATIONS AND SECTIONS TO COORDINATE M LOCATIONS AT ALL OUTLETS IN MILLWORK. REVIEW WITH ARCHITECT FOR MOUNTING: INSTRUCTIONS AND PROPOSED GROMMET SIZES AND LOCATIONS. CONTRACTOR SHALL PROVIDE AND INSTALL EXTENSION BOXES WHERE NEEDED. 12. RECEPTACLES ADJACENT TO "WET" AREAS SHALL BE GROUND FAULT INTERRUPTED (GFI TYPICAL). 13. CONTRACTOR SHALL COORDINATE MOUNTING HEIGHTS OF RECEPTACLES WITH MANUFACTURER'S RECOMMENDATIONS FOR ALL EQUIP''IENT DESIGNATED. 14. PROVIDE AND INSTALL 3 /4" EMT IN ALL LOW PARTITIONS FROM DATA AND TELEPHONE LOCATIONS TO CEILING. PROVIDE DRAG LINE IN EMT. 15_ OUTLETS SHALL BE STAGGERED RATHER THAN BACK -TO -BACK IN A SHARED PARTITION. 16. ELECTRICAL RECEPTACLES SHALL NOT BACK UP TO DATA LINE. 11. ALL CIRCUIT BREAKERS SHALL BE PROPERLY MARKED FOR THE OFFICES AND /OR FOR THE AREAS THEY SERVICE. ALL PC OUTLETS SHOULD BE CONFIGURED ON A BASIS OF THREE (3) OUTLETS PER 20 AMP CIRCUIT. H. SPECIALTIES 1. MISCELLANEOUS SPECIALTIES A. ACCESS DOORS - - MILCOR TYPE "DW" OR KARP "KDW ", WHERE REQUIRED FOR MAINTENANCE ACCESS IN G YPSU M BOARD SURFACES, B. TOILET ACCESSORIES (FOR NEW AND REMODELED TOILETS. MATCH FIXTURES IN EXIS TING RESTROOM, RE: A-0.2-1 FOR SPECIFIED BRAND AND MODEL NUMBERS) 1. TOILET FLUSH CONTROLS SHALL BE OPERABLE W/ I HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING= OR TWISTING OF THE WRIST. FLUSH HANDLE TO BE LOCATED TO OPEN SIDE OF TANK. 2. WALL HUNG SINK 3A. 1 -1/2 " X42 "o -OGRAB BAR 3B. 1 -1/2 5.5. GRAB BAR 4. I PAPER DISPENSER - WITH OUT STOPS 5. DISPENSER - DISPENSE FROM BTM. Co. TOILET SEAT COVER DISPENSER C_ FIRE EXTINGUISHER - 2A -IOBC ON WALL BRACKET_ CONFIRM REQUIREMENTS FOR TYPE, LOCATION AND QUANTITY WITH LOCAL AUTHORITIES. D. INVENTORY CAGE - OWNER FURNISHED CHAIN LINK ENCLOSURE AS MANUFACTURED BY KING WIRE PARTITIONS INC. CONTACT: KING WIRE - FRED BESHID 323 256 4848 I. FURNIS 1. CABINETS AND STORE FIXTURES A. ALL RETAIL STORE FIXTURES ARE TO BE 5UPPL'ED THROUGH OWNERS NATIONAL ACCOUNT AT HAMILTON FIXTURES INC. 2. CONTACT JOEL KATTERHAGEN 909 - 931 -3100 (WESTERN US) OR MARTY EVANS 909 - 931 -3136 (EASTERN US) J. CONSTRUCTION NOTES 1, PROVIDE CEILING ACCESS PANELS AS REQUIRED BY MECHANICAL ENGINEERS, PAINT OUT TO MATCH ADJACENT CEILING: COLOR. REFER TO MECHANICAL 4 ENGINEERING DRAWINGS. 2. CONSTRUCTION DUMPSTER MUST BE PROVIDED BY TENANT. AT TENANTS SOLE EXPENSE_ PLACEMENT BY LANDLORD PRIOR TO DELIVERY OF DUMPSTER. ALL DAMAGE TO CENTER PREMISES WILL BE BILLED TO TENANT. a� v"o C\ 1 2p�4 aP�2�w r 0 y s l o ot � Oh o tarn 1 1F O a O 3 o 3a o a� D V� N on a �a r rMME4 C R !4 ■ D ATE 04072.000 01/01/04 Ly i REVISE i �0lNlD CITY Of TtiKWA APR - 1 2004 PEFi11Aff COffM A�l v il -,..- A FLOOR PLAN_ -- NORTH (1) JOIST ., TTACHE ('I TO ABOVE - AITACH h14 - 7/16" M 08 SCRFWS. CEILING, BAC DOOM Ito CEILING, MAIN SALES NEW 3 5/8' FRAMED WALL. 25 GA. 0 24" O.C. NEW 5/8" GYP. --C BOARD BOTH SIDES. 3/16 "x1 1 FASTENERS 0 12" O.C. TOP AND BOTTOM CONTINUOUS TRACK. FINISH FLOOR 32)PARTITION DETAIL FL PLAN KEY NOT EXIST. FULL HEIGHT DEMISING: WALL TO REMAIN. NEW STOREFRONT AND GLAZING. NEW 5 5/8" METAL STUD FURRING AT 16" O.G. TO 6" ABOVE MAIN SALES CEILING WITH 5/8" GYPSUM BOARD. NEW 8' - TALL CHAIN LINK INVENTORY ENCLOSURE AND GATE FURNISHED BY TENANT, INSTALLED BY GC. 5 NEW MANAGER'S STATION, SEE DETAIL 2/A - 1, TENANT FURNISHED CONTRACTOR INSTALLED. NEW &' -0" LONG COUNTER W/ CABINETS BELOW, BY CONTRACTOR. EXIST. ELECTRICAL PANEL TO REMAIN SEE SHEET E - NEW SHELVING BY G.C. NEW 5 5/8" METAL STUD FRAMING AT 16" O.C. TO 6" ABOVE MAIN SALES 1 . CEILING WITH 5/8" GYPSUM BOARD ON EACH SIDE. SEE DETAIL 2 FOR CONNECTION BRACING TO ROOF STRUCTURE. im EXISTING DOOR, TO REMAIN. II NEW CARPET TILE PATTERN. SUPPLIED BY TENANT INSTALLED BY CONTRACTOR. EXIST. RE5TROOM FIXTURES TO REMAIN. 14 COMPUTER STATION BY G.G. SEE SHEET A -4, FIXTURE SCHEDULE. � 15 NEW DOOR, RE: DOOR AND HARDWARE SCHEDULE. C1� Q I6 TRAFFIC COUNTER FURN15HEO BY TENANT, INSTALLED BY GENERAL 2 1 ZQQ� CONTRACTOR. APR �GU I'T NEW 2AIOBG FIRE EXTINGUISHER_ EXISTING WALL TO REMAIN, 19 CUSTOM MAGENTA 6ABLE50a "x42 "). SEE DETAIL 4 4 5 /A -2.I. 22� CUSTOM MAGENTA GABLE5(18 "x42 ") SEE DETAIL & d - /A -2_I :4 ) FL OOR PLAN G NOTES I ALL BACKROOM FURNITURES SHALL BE SUPPLIED AND INSTALLED BY T- MOBILE 2 REMOVE ALL EXISTING FLOORING, PATCH 4 REPAIR 45 REQUIRED TO PROVIDE SMOOTH LEVEL FLOOR SURFACE FROM HOLES, CRACKS AND BUMPS TO ALLOW FOR NEW FLOOR FINISH, 3 PATCH AND REPAIR ALL EXISTING WALLS AS REQUIRED FOR NEW FINISH. 4, EXIT DOORS SHALL BE OPENABLE FROM THE EGRESS SIDE WIT"OUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. ALL LOCKING / LATCHING HARDWARE SHALL RELE «SE WITH ONE OPERATION SUCH 045 TURNING ONE DOOR LE' ✓ER OR PUSHING ONE PUSH PLATE ( PER APPLICAPICAL CODE:. SEE EXCEPTION BELOW FOR MAIN EXIT FROr - TENANT 5PACE5. 5. IN BUILDINGS IN OCCUPANC GROUPS B. F. M AND 5 OCCUPANCIES, TH+E MAIN EXTERIOR DOOR OR DOORS IS PERMITTED TO BE EQUIPPED (1.1►TH KE'r OPERATED LOCKING DEVICES FROM T"E EGRESS SIDE PROvIDED: THE LOCKING DEVICE IS READILY DISTINGU'5 "ABLE A 5 LOCKED. THE MAIN EXIT CON51STS OF A SINGLE DOCK O R PEA IR OF DOORS IF T)-SERE 1 5 A READIL'r VISIBLE DURABLE SIGN CN OR ADJACENT TO THE DOOR ON T"E EGRESS SIDE 5T,4TING DOOR TO REr"?AIN UNLOCKED WHEN BUILDING 15 OCC *r"E SIGN SHALL BE IN LETTERS NOT LE55 THAN I" HIGH ON 4 CCNT4Z•49T'NG BACKGROUND. Wr -4ERE EGRESS DOORS ARE USED 'N Ate► RS APPROVED 4U'rO"4TIC FLUSH BOLTS SHALL BE PERT " ED TC BE USED PRCvIDED TWA' '64E DOOR LEAF HAv�NG T•1E ""UrC"ATIC r-LUSN BCLT5 N45 NCT NO DOORKNOB CPR 5„RF «CE "CUNTED WARDU04RE. r "E UNLATCHING OF 4N- LEAF 5"4�.L NOT REQU'RE "CRE '"'N ONE OPERATION. , `PER CODE'. 6 INTERIOR WALLS PER''TENT "r IONS ANN, 'E`^AOR•:►R` PARTITIONS Ww'C -+ EXGEED h FEE"' 'N WE'G "' NC,-JD LNG '�E R r-'N S" MATERIALS 3E DE5 'O 'RES 5"' -%L. LC «C5 'C �AJIW C� 'rwEY ARE SUBJEC'ED B.' NC' L. ESS `" N 4 -+CR ZCti'4` L ^4C 5 FOUNDS °ER 5Gj «RE FCC' PER C•+B,.E CC :E �. CONTRACTOR 5N «�� aRE° «ARE :•'vC 1 DAIN - WALL PER SPECIFICATIONS SEE 5 WALLS CEILING FOR APR - 1 2004 PEFW CEWER FLOW FLM .. w • 0 `✓ERIFY CE' BULKHE AD ,-L 14' -0" " (E) MALL SPLICE NEL FRAMING W, EXISTING EXISTING '�-- MALL NEUTRAL STRIP PATCH AND REPAIR AS NEEDED. PAINT PER MALL REQUIRMENTS. 1 17 EXTERIOR ELEVATION SCALE: 1 /4 " =1' -0" EXTERIOR ELEVATION VERIFY (E BULKHEAD 14 ' -011 (E) MALL CEILING 23 25 R to 1 N R I I wo : ,e " 12 i 8 1 2' -o%" 1 N r e I BEYOND I 14 121-011 ilk B.O. SUPPORT qV FRAMING I1' -0 "}- 3 �� 8 1 " ; 33/ Iq BEYOND EXTERIOR ELEVATION SCAT F: 1 '4" 1' 0" • • • GENERAL NOTES A FIELD ✓ERIFY ALL EXISTING MAL` STRuCTuRES BULKHEAD : C N S *RUCT'ON LEASE t-INE "DCA' (DESIGN CONTROL AREA. Lir"►ITS ETC COORDINA *E 1,04LL I OPERATIONS MANAGER. PRIOR TO BEGINNING DV*10LITION OR l`*CNSTRUCTION. P GLASS PANES DOORS PANELS ETC. SHALL BE TEMPERED t0 "SEE* LOCAL CODES ALL EXPOSED EDGES OF GLASS SO44LL "A ✓E POLISHED EDGES C. F!ELD ✓ERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION ANG A ✓.,JSr D'►"1ENSIONS TO COORDINATE WITH INTENDED ALIGNMENT OR RELATIONSHIPS KEYED NOTES I. ROLL DOWN GRILL BY ALUMATEK, INC. MOTOR OPERATED JNIT WITH E I � EGRESS DEVICE. DOORS SHALL REMAIN SECURED IN FULL OPEN POSITION WHILE PREMISES 15 OPEN TO THE GENERAL PUBLIC AND SHALL NOT BE CLOSED IF THERE ARE MORE THAN 10 OCCUPANTS WITHIN THE PROMI AND OPENABLE WITHOU THE USE OF KEY OR SPECIAL KNOWLEDGE WHEN SPACE IS OCCUPIED. 2. )�" CLEAR TEMPERED GLASS. BUTT GLAZED WITH OPEN EDGE JOINTS 3 /8 , MAX. 5 SPACING, WITH ANODIZED GLASS CLIPS. 3. ALUMINUM STORE FRONT BY UNITED STATES ALUMINUM. CUT DOWN TOP AND BOTTOM MULLIONS TO 2" HEAD s 6" BASE OVERALL HEIGHTS, RESPECTIVELY. 4. BIRCH GABLE. RE: A2.1 -6 AND 1. 5. MAGENTA GABLE. RE: A2.1 -4 AND 5. 6. T- MOBILE SIGN AND ACCENT CHANNELS W/ 3/4" PUSH -THRU PLEXI, MIN. SIGN 5� go-RA PACKAGE UNDER SEPARATE SUBMITTAL. �. L� XI 3M DUSTED CRYSTAL FILM 31725 -314 DIGITS , . AFFIX TO INTERIOR OF GLAZING. PROVIDE AND INSTALL TO MEET LANDLORD REQUIRMENTS_ 8. %" GYPSUM WALL BOARD, PAINTED PI. RE: SHEET A - 5 S. 3/4" SOLID) BIRCH END CAP. 10. SATIN ALUM, FINISH BASE BOARD. 11. 3/8" PLYWOOD, FIRE RESISTANT PER CODE AND LANDLORD REQUIREMENTS. 12. 3 5/8" METAL STUD BOX BEAM. 13- 5 % "THICK ALUM. LAY UP PANELS, MAGENTA. 14. 3% 16 GA. METAL FRAMING AT 24 O.G., UNLE55 NOTED OTHERWISE. NO WOOD FRAMING ALLOWED. CONNECT AT EXISTING MALL STRUCTURE. 15. ALUMN. "F" CHANNEL, SATIN FINISH. 16. ALUMN_ "L" CHANNEL, POWDER COATED, MAGENTA. 11. ALUMN. "J" CHANNEL, CLEAR ANODIZED. 18. ALUMN. "U" CHANNEL, POWDER COATED, MAGENTA. 19. OVERHEAD GRILL TRACK. 20. DOWNL IGHT, SEE SHEET E-2 21. 4" ALUMN. CHANNEL, SATIN BRUSHED FINISH. 22. ILLUMINATED T- MOBILE SIGN W/ 3/4" PLEXI. PUSH -THRU MIN.. COORDINATE WITH G.C./ > 04 ELECTRICIAN AND SIGN CONTRACTOR. SIGN SUBMITTAL UNDER SEPARATE SUBMITTAL. 23. JUNCTION BOX FOR ILLUMINATED T- MOBILE SIGN, 24. BLOCKING 25. 6" CLEAR ANODIZED CHANNEL. 26. 3/4" MAPLE VENEER MDF 21. 3g /8" Irc GA. CONTINUOUS METAL TRACK. 28. ROLLDOWN GRILL SUPPORT BY ALUMATEK, INC. (11"xll" CABINET). 29. ALUM. PANEL WITH BACKER SECURE TO METAL STUDS WITH CLIP ANGLES AT BOTTOM AND METAL STUD. TYP. 30. SUSPENDED ACOUSTICAL CEILING, SEE SHEET Al 31• No" x 2V" HILTI HIT 150. LOCATIONS AS SHOWN. NOT USED 32. b 33. 0 10 "TEK" SCREWS, 6" O.C. UNLESS NOTED OTHERWISE. NOT USED 3 4. 1 2 " TH I CK N A T „ , ALUM L UP r-, ,, NE T B NOT USED 35. 3 5'' TA FR FR AMING. 36.3/4" X 3/4" ALUM. CHANNEL, PAINT FIN15H SATIN BLACK. BLIND FASTEN TO BACKUP MATERAL (NO EXPOSED FASTENERS). APPROO AFINISH� FLOOR 5 WR I CAL SEECTM - MAGMA GABLE 8 -0 I� 0' -6" I� EXISTING WALL 1 CLEAR SPACE FOR MELD ADJUSTMENT 6 F+oRao►ff& WCTM - sc� t� -t-or I ' - -� 27 12' -0" AL FINISH FLOOR Al_ 7 MINE%~ v�nc� sECTa� - s�CV2W -Or' Q 3 I � I � I � 5 ... f h o 5� go-RA w oi l 0 i _ LA- k� vi N H on W 0 > 04 z R A � R R � w � i O.IE 0072.0W DATE 01/01/04 -lRAWN LY 9 �Y1SE C I i i CITY Of TUKW A APR - 1 2004 PEWT OOM ;►.� : r SECTKM AM WTAU 7 ��� F • A�2 ApR 2 1 20Q� r Hoa¢aWM. %CTM - sca.E: 1 yr -t-W I • ) DEMOLITION - PLAN SCALE 1/4" 1'4r C� � 21 2�ti� p� r h I � � a ow •►� m 'd ex gA�o� LI R M O ° �i 3 •IL V • N on N d CA �a a • f �} I I a PQCJECT DATE aori.WO 01/01/04 �q�wN CHECKED I REOSEC WV OKA APR - 1 zoo4 PERwr S nt;c SNEf A�2 I F 2 KEYED NOTES I REMO EX ISTING WALL AND ALL RELATED ITEMS PATCH REPAIR AND PAINT WALLS AS REQUIRED WHERE DEMO WORK OCCURS. ? REMOVE ALL EXISTING INTERIOR AND FLOOR FIXTURES 'MILLWOORK. PATCH AND REP4• "R .45 NEEDED. 3. REMOVE ALL EX ISTING LIGHT FIXTU TILE CEILING a GRID AND GYP, BRC. CEILINGS d. REMOVE EXIST. TILE. REPAIR FLOOR AS REQUIRED FCR NEW FINISHES. REPAIR MALL TILE WHERE DEMO, WORK OCCURS. 5. EXISTING COLUMN TO REMAIN. 6. REMOVE AND INFILL EXISTING DOORWAY. 8 . REMOVE EXISTING STO REFRONT GLAZINCs. 9 . REMOVE EXISTING SHOW W INDOW PLATFORM. IO . REMOVE EXISTING ROLL DOWN GRILL. 3 ) DEMOLITI NOTES I. REMOVE ALL EXISTING INTERIOR PARTITIONS, DOORS AND DOOR FRAMES SCHEDULED FOR DEMOLITION. REMOVE ALL MILLWORK, EQUIPMENT, ETC. ATTACHED TO PARTITIONS OR COUNTERS SCHEDULED FOR DEMOLITION. VERIFY WITH CONTRACTOR WHICH ITEMS ARE TO BE SAVED AND STORED FOR REUSE. 2. REMOVE EXISTING ACOUSTIC CEILING GRID AND TILES LIGHT FIXTURES, AS SCHEDULED FOR DEMOLITION AND AS REQUIRED BY PARTITION DEMOLITION AND NEW CONSTRUCTION WORK. 3. REMOVE EXISTING ELECTRICAL DEVICES, OUTLETS, TELEPHONE AND DATA JACKS AND THERMOSTATS IN PARTITIONS SCHEDULED FOR DEMOLITION. MODIFY EXISTING WIRING AS REQUIRED BY NEW CONSTRUCTION OR, IF NOT REQUIRED, TERMINATE AND CAP OFF AT NEAREST PANEL OR SOURCE ABOVE CEILING. VERIFY WITH LANDLORD WHICH ITEMS ARE TO BE SAVED AND STORED FOR REUSE. 4. RELOCATE EXISTING HVAC DUCTWORK, CEILING DIFFUSERS AND RETURN GRILLES AS SHOWN ON A -3. 5. REMOVE ALL CARPET. Fo. REUSE EXISTING DOORS FRAMES, HARDWARE, LIGHT FIXTURES ELECTRICAL DEVICES HVAC GRILLES, ETC. FROM DEMOLITION INVENTORY OR SCHEDULED. CAREFUL REMOVAL, STORAGE AND REINSTALLATION OF ALL MATERIALS AND EQUIPMENT 15 REQUIRED TO PREVENT DAMAGE. REPAIR AND REFINISH ALL DAMAGED MATERIALS AND EQUIPMENT AS REQUIRED FOR PROPER INSTALLATION. ALL MATERIALS AND EQUIPMENT NOT REQUIRED FOR REUSE BY NEW CONSTRUCTION ARE TO BE STORED FOR FUTURE USE. 1. REMOVE ALL CONSTRUCTION DEBRIS FROM AREA. REPAIR ALL ADJACENT DAMAGED SURFACES, AS NECESSARY. PREPARE ALL DAMAGED SURFACES FOR FIN15HES AS SCHEDULED OR REFINISH TO MATCH E XISTING FINISH. REPLACE DAMAGED CEILING TILES*- REPAIR OR REPLACE DAMAGED CEILING GRID. 8. PROVIDE A SMOOTH, NEAT, CONTINUOUS APPEARANCE WHERE DEMOLITION WORK MEETS ADJACENT EX15TING WORK. REMOVE EXISTING FINISHES AS REQUIRED TO PROVIDE NEAT, STRAIGHT SEAMS AND TRANSITIONS BETWEEN EXISTING AND MATCHING NEW FINISHES_ 9. REPLACE OR RELOCATE, IN ACCORDANCE WITH LOCAL CODES, ALL FIRE SUPPRESSION AND FIRE ALARM EQUIPMENT DISTURBED BY DEMOLITION WORK. MAINTAIN INTEGRITY OF FIRE SUPPRESSION AND FIRE ALARM 5YSTEMS. ,...- 4 I i 2 KEYED NOTES I REMO EX ISTING WALL AND ALL RELATED ITEMS PATCH REPAIR AND PAINT WALLS AS REQUIRED WHERE DEMO WORK OCCURS. ? REMOVE ALL EXISTING INTERIOR AND FLOOR FIXTURES 'MILLWOORK. PATCH AND REP4• "R .45 NEEDED. 3. REMOVE ALL EX ISTING LIGHT FIXTU TILE CEILING a GRID AND GYP, BRC. CEILINGS d. REMOVE EXIST. TILE. REPAIR FLOOR AS REQUIRED FCR NEW FINISHES. REPAIR MALL TILE WHERE DEMO, WORK OCCURS. 5. EXISTING COLUMN TO REMAIN. 6. REMOVE AND INFILL EXISTING DOORWAY. 8 . REMOVE EXISTING STO REFRONT GLAZINCs. 9 . REMOVE EXISTING SHOW W INDOW PLATFORM. IO . REMOVE EXISTING ROLL DOWN GRILL. 3 ) DEMOLITI NOTES I. REMOVE ALL EXISTING INTERIOR PARTITIONS, DOORS AND DOOR FRAMES SCHEDULED FOR DEMOLITION. REMOVE ALL MILLWORK, EQUIPMENT, ETC. ATTACHED TO PARTITIONS OR COUNTERS SCHEDULED FOR DEMOLITION. VERIFY WITH CONTRACTOR WHICH ITEMS ARE TO BE SAVED AND STORED FOR REUSE. 2. REMOVE EXISTING ACOUSTIC CEILING GRID AND TILES LIGHT FIXTURES, AS SCHEDULED FOR DEMOLITION AND AS REQUIRED BY PARTITION DEMOLITION AND NEW CONSTRUCTION WORK. 3. REMOVE EXISTING ELECTRICAL DEVICES, OUTLETS, TELEPHONE AND DATA JACKS AND THERMOSTATS IN PARTITIONS SCHEDULED FOR DEMOLITION. MODIFY EXISTING WIRING AS REQUIRED BY NEW CONSTRUCTION OR, IF NOT REQUIRED, TERMINATE AND CAP OFF AT NEAREST PANEL OR SOURCE ABOVE CEILING. VERIFY WITH LANDLORD WHICH ITEMS ARE TO BE SAVED AND STORED FOR REUSE. 4. RELOCATE EXISTING HVAC DUCTWORK, CEILING DIFFUSERS AND RETURN GRILLES AS SHOWN ON A -3. 5. REMOVE ALL CARPET. Fo. REUSE EXISTING DOORS FRAMES, HARDWARE, LIGHT FIXTURES ELECTRICAL DEVICES HVAC GRILLES, ETC. FROM DEMOLITION INVENTORY OR SCHEDULED. CAREFUL REMOVAL, STORAGE AND REINSTALLATION OF ALL MATERIALS AND EQUIPMENT 15 REQUIRED TO PREVENT DAMAGE. REPAIR AND REFINISH ALL DAMAGED MATERIALS AND EQUIPMENT AS REQUIRED FOR PROPER INSTALLATION. ALL MATERIALS AND EQUIPMENT NOT REQUIRED FOR REUSE BY NEW CONSTRUCTION ARE TO BE STORED FOR FUTURE USE. 1. REMOVE ALL CONSTRUCTION DEBRIS FROM AREA. REPAIR ALL ADJACENT DAMAGED SURFACES, AS NECESSARY. PREPARE ALL DAMAGED SURFACES FOR FIN15HES AS SCHEDULED OR REFINISH TO MATCH E XISTING FINISH. REPLACE DAMAGED CEILING TILES*- REPAIR OR REPLACE DAMAGED CEILING GRID. 8. PROVIDE A SMOOTH, NEAT, CONTINUOUS APPEARANCE WHERE DEMOLITION WORK MEETS ADJACENT EX15TING WORK. REMOVE EXISTING FINISHES AS REQUIRED TO PROVIDE NEAT, STRAIGHT SEAMS AND TRANSITIONS BETWEEN EXISTING AND MATCHING NEW FINISHES_ 9. REPLACE OR RELOCATE, IN ACCORDANCE WITH LOCAL CODES, ALL FIRE SUPPRESSION AND FIRE ALARM EQUIPMENT DISTURBED BY DEMOLITION WORK. MAINTAIN INTEGRITY OF FIRE SUPPRESSION AND FIRE ALARM 5YSTEMS. ,...- 4 I • • 6 LIGHTING SCHEDULE a 1I' -0" AFF. CEILING MOUNT TRACK L IGHTS • IV-0" A .FF. SPRINKLER HE (TYP.) GRILL, RE: DOOR SCWEDULE R PLAN E h, 1C1 I 1-%I�M IGCC_s 6 II' -0" A.F.F. I 1 ' r NORTH • �J SHEET NOTES /CEILING MOUNTED DEVICES I SEE S HT A -5 FOR ADDITIONAL NOTES AND LEGENDS. 2. SEE ENGINEERING D RAWINGS FO ExIT SIGN SPECIFICATION 3. PROVIDE BLACK POP -OFF SPRINKLERS ON CEILING "CLOUDS" REMAINING PORTION OF CEILING SHALL RECEIVE WHITE POP -OFF SPRINKLERS. 4. EXIT SIGNS ARE REQUIRED (PER APPLICABLE CODE. 5. EXITS AND EXIT PATHWAYS SHALL BE ILLUMINATED WITH A MINIMUM OF ONE FOOT - CANDLE AT AT FLOOR LEVEL ANY TIME THE BUILDING 15 OCCUPIED. PROVIDE EMERGENCY ILLUMINATION OF EXIT PATHWAYS. (PER APPLICABLE CODE). 43 CEILING GENERAL NOTES 1. VERTICAL HANGERS: SUSPENSION WIRES SHALL NOT BE SMALLER THAN NO. 12 GAGE SPACED AT 4' -0" ON CENTER OR NO. 10 GAGE AT 5' -0" ON CENTER ALONG EACH MAIN RUNNER EACH VERTICAL WIRE SHALL BE ATTACHED TO THE CEILING SUSPENSION MEMBER AND TO THE SUPPORT ABOVE WITH A MINIUM OF THREE TURNS. ANY CONNECTION DEVICE AT THE SUPPORTING CONSTRUCTION SHALL BE CAPABLE OF CARRYING NOT LESS THAN 100 POUNDS. 2. SUSPENSION WIRES SHALL NOT HANG MORE THAN I IN (p OUT OF PLUMB UNLESS COUNTERSLOPING WIRES ARE PROVIDED. WIRES SHALL NOT ATTACH TO OR BEND AROUND INTERFERING MATERIAL OR EQUIPMENT. A TRAPEZE OR EQUIVALENT DEVICE SHALL BE USED WHERE OBSTRUCTIONS PRECLUDE DIRECT SUSPENSION. TRAPEZE WSPEN51ONS SHALL BE A MINIMUM OF BACK TO BACK I - 114" COLD - ROLLED CHANNELS FOR SPANS EXCEEDING 48 ". 3. PERIMETER HANGERS: THE TERMINAL ENDS OF EACH CROSS RUNNER AND MAIN RUNNER SHALL BE SUPPORTED INDEPENDENTLY A MAXIMUM OF 8 INCHES FROM EACH WALL OR CEILING DISCONTINUITY WITH NO. 12 GAGE WIRE OR APPROVED WALL SUPPORT. 4. LATERAL FORCE BRACING, HORIZONTAL RESTRAINTS SHALL BE EFFECTED BY FOUR NO. 12 GAGE WIRES SECURED TO THE MAIN RUNNER WITHIN TWO INCHES OF THE CROSS RUNNER INTERSECTION AND SPLAYED 90 DEGREES FROM EACH OTHER AT AN ANGLE NOT TO EXCEEDING 45 DEGREES FROM THE PLANE OF THE CEILING. A STRUT FASTENED TO THE MAIN RUNNER SHALL BE EXTENDED TO THE STRUCTURAL MEMBERS SUPPORTING THE ROOF OR FLOOR ABOVE. THE STRUT SHALL BE ADEQUATE TO RESIST THE VERTICAL COMPONENT INDUCED BY THE BRACING WIRES. THESE HORIZONTAL RESTRAINT POINTS SHALL BE PLACED 12 FEET ON CENTER IN BOTH DIRECTIONS WITH THE FIRST POINT WITHIN 6' -0" FROM EACH WALL. ATTACHMENT OF THE RESTRAINT WIRES TO THE STRUCTURE SHALL BE ADEQUATE FOR THE LOAD IMPOSED. 5. LATERAL FORCE BRACING MEMBERS SHALL BE SPACED A MINIMUM OF 6 INCHES FROM ALL HORIZONTAL PIPING OR DUCT WORK THAT 15 NOT PROVIDED WITH BRACING RESTRAINTS FOR HORIZONTAL FORCES. BRACING WIRES SHALL BE ATTACHED TO THE GRID AND TO THE STRUCTURE IN SUCH SUCH A MANNER THAT THEY CAN SUPPORT A DESIGN LOAD OF NOT LESS THAN 200 POUNDS OR THE ACTUAL DESIGN LOAD, WHICHEVER 15 GREATER, WITH A SAFETY FACTOR OF 2. PERIMETER MEMBERS FOR TILE CEILING5 ENDS OF MAIN RUNNERS AND CROSS MEMBERS SHALL BE TIED TOGETHER TO PREVENT THEIR 5PREADING. MAIN RUNNERS AND CROSS RUNNERS MAY BE ATTACHED TO THE PERIMETER MEMBER AT TWO ADJACENT WALLS WITH CLEARANCE BETWEEN THE WALL AND THE RUNNERS MAINTAINED AT THE TWO OTHER WALLS. LIGHTING FIXTURES: ALL LIGHTING FIXTURES SHALL BE POSITIVELY ATTACHED TO THE SUSPENDED CEILING SYSTEM. THE ATTACHMENT DEVICE SHALL HAVE A CAPACITY OF 100 PERCENT OF THE LIGHTING FIXTURE WEIGHT ACTING IN ANY DIRECTION. NO. 12 GAGE HANGERS SHALL BE ATTACHED TO THE GRID MEMBERS WITHIN 3 INCHES OF EACH CORNER OF EACH FIXTURE. TANDEM FIXTURES MAY UTILIZE COMMON WIRES. LIGHTING FIXTURE WEIGHING LESS THAN 56 POUNDS SHALL HAVE, IN ADDITION TO THE REQUIREMENTS OUTLINED ABOVE, TWO NO, 12 GAGE HANGERS CONNECTED FROM THE FIXTURE HOUSING TO THE STRUCTURE ABOVE. THESE WIRES MAY BE SLACK LIGHTING FIXTURES WEIGHING 56 POUNDS OR MORE SHALL BE SUPPORTED DIRECTLY FROM THE STRUCTURE ABOVE BY APPROVED HANGERS. PENDANT -HUNG LIGHTING FIXTURES SHALL BE 5UPPORTNG DIRECTLY FROM THE STRUCTURE ABOVE USING NO. 9 GAGE WIRE OR APPROVED ALTERNATE SUPPORT WITHOUT U51NG THE CEILING SUSPENSION SYSTEM FOR DIRECT SUPPORT. DO NOT ATTACH OR SHOOT PINS TO THE ROOF DECK. HANG FROM EXISTING JOIST OR BEAMS. SPAN STUD OR UNISTRUCT OR INTERMEDIATE MEMBERS, WHERE NECESSARY. SUSPENDED CEILING SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH APPLICABLE CODE. RELOCATE EXISTING SPRINKLER HEADS AS NEEDED. RELOCATION OF FIRE SPRINKLER H E A DS SHALL COMPLY WITH APPLICABLE CODE. AS REGULATED BY THE LOCAL FIRE DEPARTMENT LOCAL FIRE CHIEF SHALL BE NOTIFIED WHEN o4NY REQUIRED FIRE ALARM SYSTEM IS PLACED TEMPORARILY OUT OF SERVICE AND UPON RESTORATION OF SERVICE (PER APPLICABLE CODE). REMOVE AND RE- INSTALL SPEAKERS, GRILLES SPRINKLERS ETC. THAT ARE AFFECTED BY NEW CEILING WORK. COORDINATE DEMO OF LIGHTS WITH ELECTRICAL PLANS. �F ��oio ��� ApP ppvtp � 2o a4 o 2 as TA) o � y�� I� A r � y LOW- � o ! r A i t s � Q�o E ofi Q Q�o sb =- Z b O a oi O o LLA 3i • LL U� • vd a -- N 'v► IA r4 ILI r Q a 00 �• a � . J NW 4 V r► ! I PRGA c DATE MC72.000 0 D RAWN CH+FCKEC' lr g RfV+SEC I I �� APR - 1 2004 ��Tlk PUN yNCt' A � .. 3 r Al 1 r 9 i QTY. SYMBOLS our- - DESCRIPTION LOCKER WATER COOLER U/G SAFE 24 ''W X 2 1 "H >t I( 11 G7 WE 1 20 LBS. NO 1. ALL BACKROOM FIXUTURES t FURNISHINGS TO BE PROVIDED BY T- MOBILE (: o NOTE: RE: 41/A -5 FOR F INISH SCHEDULE � 0. CAS POD DETAIL IAI 9>'-C" COUNTER - ' BY CONTRACTOR �L GET MORE MURAL Tro I WALL MTD. ACCESSORY PANEL SALES SUPPORT -3 STATIONS T 19�3 - ' T Iro G BRAND MURAL T14.1 J BRAND MURAL T26 - PRE PAID T15 POSTER FRAME WALL "TD. ACCE SSOR'r PANEL TIS EASEL STAND 13' -10" `- T4 WINDOW DI FIXTURE /FLOOR FINISH PLAN _ 1 o °o •o• 1, T32.4 WALL MTD DIVIDER FIXTURE IP Who M oo I (E) I MANAGER'S rn ,.--•. DE r� R I I I I T1 ACCESSORY SPINNER WALL PANEL T 10 , T20.31 POSTER i FRAME X3 T15 i-- M COVERAGE PO TER T21 j WALL PANEL 1 TIO L� CONSUMER CABINET- 3 STATIONS T9.3 T1 ---------- ACCESSORY ; POSTER FRAME X3 SPINNER i'�'� ' T15 - T3.1 �'� PRODUCT I SL AND BRAND MURAL •! Kr i TS NORTH PROSUMER CABINET - 3 STATIONS I T16 FIXTURE LIST • T FIXTURE QTY". DESCRIPTION GO I"'►►~1 EN 5 T1 3 CASH POD • T1.1 2 GASH POD • ' T3.1 I PRODUCT ISL AND 4 PHON STANDS 2 • 2 WIDE COUNTER TRA T3.2 C PRODUCT ISL AND 4 PHONE STANDS 2 • 2 WIDE C TRAY T3.3 0 PRODUCT I SL AND 12 PHON STANDS, 2 • 2 WIDE TRAY T4 I WINDOW DISPLAY .C,ah • T5 0 BRAND SIGN Tb 2 WALL MO UNTED ACCESSORY PANEL • T1 2 ACCESSORY SPINNER • T8 I BRAND MURAL • T8.1 C BRAND MURAL • T9.1 0 CONSUMER CABINET - STATION 1 * 3 PKT. BROCHURE, 3 PH, STDS, 2 • 2 WIDE COUNTER TRAY T9.2 O CONSUMER CABINET -2 STATIONS 1 3 PKT. BROCHURE, 6 PH. STDS 3 • 2 WIDE COUNTER TRAY T93 I CONSUMER CABINET -3 STATIONS 2 • 3 PKT. BROCHURE, 9 PH. STDS, 4 • 2 WIDE COUNTER TRAY TIC 2 WALL PANEL 2 SHELVES RAM 5 PKT. BROCHURE R T11 C DISPLAY CASE • T12 C PHONE STANDS « T13 I GET M ORE MURAL T14.1 1 BRAND MURAL • T14.2 1 BRAND MURAL • T14.3 0 BRAND MURAL • T15 I POSTER FRAME T16 3 TRACK 91' -5 3/4" LIN. FT. T11.3 0 DIVIDER FIXTURE 3 PANEL T1 C DIVIDER FIXTURE 4 PANEL T11.5 0 DIVIDER FIXTURE 5 PANEL T18 I EASEL STAND ' T19.1 0 SALES SUPPORT -1 STATION T19.2 C SALES SUPPORT -2 STATIONS • T19.3 I SALES SUPPORT -3 5TATION5 « T20.1 0 PRO5UMER COUNTER -1 STATION 3 PHONE STANDS, 2 6 2 WIDE COUNTER TRAY T20.2 0 PR:OSUMER COUNTER -2 STATIONS 6 PHONE STANDS, 2 • 2 WIDE COJNTER TRAY T20.3 I PROSUMER COUNTER -3 STATION5 9 PHONE STANDS, 2 • 2 WIDE C OUNTER TRAY T21 I COVERAG=E POSTER « T22 0 COUNTER TRAP • T23 0 BROCHURE HOLDER -3 POCKET « T24 0 BROCHURE HOLDER -5 POCKET « T25 0 GLASS DISPLAY CASE -WALL MTD. TBD. - AS REQUIRED T26 I PRE PAID • T2 0 BACKROOM COUNTER, SEE I /A -1 BY G.C. T28 I MANAGER'S DESK, SEE 214-1 BY G.C. T29 5 STOOL, TO LATER SPEC. T32.4 I WALL MTD DIVIDER FIXTURE COMPUTER I BUSH VISIONS PERSONAL COMPUTER STATION STATION, CzALAXY FINISH- ORDER B Y G.C. 1 WWW_5TAPLES.COM THE ACCESSIBLE RESTROO" L,4vATORIE5 5HALL HA\/E ,4 MAXIMUM "EIGHT OF 34 INCHE5. WITH A MINIMUM KNEE CLEr4R,4NCE OF 29 INCHES AND THAT THE DRAIN PIPING SHALL BE INSULATED. PER APPL IGABLE CODE. ALL PUBLIC: COUNTERS WITH A HEIGHT BETWEEN 28 AND 34 INCHES, AND BE A MINIMUM OF 36 INCHES LONG WITH KNEE CLEARANCE OF 2'1 INCHES ON BOTH PUBLIC AND EMFLO�T EE SIDES. NOTE: KNEE CLEARANCE 15 NOT REQUIRED FOR 51DE APPROACH. (PER APPLICABLE CODE). FOR ADDITIONAL INFORMATION. SEE ACCE55115ILIT�' DETAILS ON .4 - 0.2. 4 � 2ad 1 G � i z z m a a a w 7 te a' A A Ila !! A a w ■ w � PROJECT 0072: DRAWN i Lr i REVSED Olt i gel Il r-,8 F! d�q I la p xm u u 0 I o Z• � o 1 3 oil le O LL tI� I I i I i SATE 01/01/04 APR - 1 1004 i PEWT c"ff• " F1 am Fem A�4 PLMI It 0 r 6 4 FNW gas= 5 DESCR PAINT, BENJAMIN MOORE, CLOUD WHITE "OC -130 NWD. TNRSLD. REMARKS MFG FINISH/REMARKS DIM. PROS I ED 0LAS9 MFG. NUMBER PORCELAIN TILE, OLYMPIA TILE- POLISHED FLAVIKER (LCB) 12" X 12" G T38 GRAPHITE ACK GROUT ° MATCH EX,46-T,NG MALL TILE TO REAR FAGE SCHL'4GE OF MAGNETA GABLE. O CARPET, M LL K N CARPET- T UD , WINDOW PANE SUMMER DA 0 185 TENANT FURNISHED CONTRACTOR INSTALLED. LATCHSET ACCENT CARPET, P /2cJ03COLOR ACCENTS, COLOR "161, FOSSIL, 18 "X18" ON COMFORT PLUS CUSHION BACK. TENANT FURNISHED CONTRACTOR INSTALLED. COLLINS t AIKMAN, TRIAD MAT SERIES, STYLE: MAXIMUM FASHION, COLOR 0 00154 CHARCOAL v VINYL COMPOSITE TILE, ARMSTRONG- STANDARD EXCELON IMPERIAL TEXTURE '"51889 COOL WHITE. CONTRACTOR FURNISHED AND INSTALLED. Q RUBBER COVE BASE, ARMSTRONG- GRAPHITE GRAY Mrol, 4" COVE PROFILE UBBER COVE BASE, ARh'15TRONG- GRAPHITE GRAY 0 61, 4 COVE PROFILE. CONTRACTOR FURNISHED AND INSTALLED. __eAtTIC SILENCERS 5IRC14 PLYWOOD, CLEAR FINISH, BY FABRICATOR IVES 2 1 A METAL, SCHLAGE CLE;AR SATIN ANODIZED ALUMINUM, BY FABRICATOR IFINIS1 RIVACYSET SILVER F-VIZIDER C ., FINISH I - . HINCsES ANODIZED MA5ENTA ALUMINUM TO MATCH CORPORATE STANDARD McKINNEY SATIN ALUMINUM O SILENCERS -- D ACRY --L IVES , , 1 SI GN . 8' C - O. CLI , � je MTL MFR. 5 3 NEW OVERHEAD COILING DOOR 2 - . 3' - 0" 1' - 0" 1 3/4' CEILING TILE, ARMSTRONG- DESIGNER SERIES 1 PARM 8334, 24 "X48" SQUARE LAY -IN, 15 1Iro" TEE. HIN GES CEILING TILE, ARMSTRONG- DESIGNER SERIES, *ARM 8388, 24 "X24" TEGULAR EDGE, 15116" TEE. ■r - P0951151tIT155, TEXTURE 0 800 2 10 "COOL 041TE" I 3 WIRE MESH Z DOC)g - &gum= DOOR A L FRAME NWD. TNRSLD. REMARKS MFG FINISH/REMARKS DIM. MFG. NUMBER 1 ° AL SERIES SCHL'4GE SATIN ALUMIN a LATCHSET PASSAGE LATCH "D SERIES/RNODES OR EQUAL" 1 PR HINGES 4.5 X 4.5 TA2114 U5 26D Q SATIN ALUMINUM MAT./ SILENCERS 0 20 IVES 2 1 A I LOCATION SCHLAGE SATIN ALUMINUM IFINIS1 RIVACYSET PRIVACY LOCK FINISH I 11/2 HINCsES 4.5 X 4.5 TA2114 US 26D McKINNEY SATIN ALUMINUM O SILENCERS 0 20 IVES 1 SI GN ENTRY 8' C - O. _ ALUM. MTL MFR. 5 3 NEW OVERHEAD COILING DOOR 2 INTERIOR 3' - 0" 1' - 0" 1 3/4' PAINT WD HIN GES HM. PAINT I I 3 WIRE MESH BLDG. STD. 4 OWNER EXIT DEVICE ARM -A -DOOR OWNER SUPPLIED, CYLINDER LEVER HINGED 3' -0" 6' -10" FURNISHED PANIC DEVICE' 888 - 168 - 1301 3 LOCK TENANT DOOR BY TW I L A GORE 801- 284 -1015 TO ORDER. FURNISHED, KING WIRE ALL HARDWARE BY DOOR". MANUF-ACTURE. CONTRACTOR PARTITIONS PROVIDE EMERGENCY ACCESS RELEASE ALL DOOR HARDWARE TO BE COMMERCIAL GRADE SATIN INSTALLED 4 EXISTING TO REMAIN EXIST E XI ST EXIST EXIST PAINTED SEMI-GLOSS UNLESS OTHERWISE SPECIFIED. MTL EXIST 4 AND SLIDING) SHALL NAVE A SMOOTH UNINTERRUPTED 5URFACE OR SHALL BE PROVIDED WITH 10 - INCH 1 SMOOTH NOTE: ALL HARDWARE SHALL 3 LE 3 HARD WARE sc COMPL ANT. _.,.,,......._ SET QTY. ITEI'`''I DESCRIPTION MFG FINISH/REMARKS MFG. NUMBER 1 LEVER AL SERIES SCHL'4GE SATIN ALUMIN LATCHSET PASSAGE LATCH "D SERIES/RNODES OR EQUAL" 1 PR HINGES 4.5 X 4.5 TA2114 U5 26D McKINNEY SATIN ALUMINUM 3 SILENCERS 0 20 IVES 2 1 LEVER AL SERIES SCHLAGE SATIN ALUMINUM RIVACYSET PRIVACY LOCK "D- SERIES/RHODES OR EQUAL" 11/2 HINCsES 4.5 X 4.5 TA2114 US 26D McKINNEY SATIN ALUMINUM O SILENCERS 0 20 IVES 1 SI GN RESTROOM MEET ALL LOCAL AGCESSABL IT1' GODE5 3 1 LEVER LATCH - GALVANIZED STEEL 1 1/2" PR HIN GES - GALVANIZED STEEL I DOORSTOP BLDG. STD. 4 1 EXIT DEVICE ARM -A -DOOR OWNER SUPPLIED, EXIT ONLY SERVICES CONTRACTOR PANIC DEVICE' 888 - 168 - 1301 INSTALLED. CONTACT: TW I L A GORE 801- 284 -1015 TO ORDER. ALL HARDWARE BY DOOR". MANUF-ACTURE. PROVIDE EMERGENCY ACCESS RELEASE ALL DOOR HARDWARE TO BE COMMERCIAL GRADE SATIN STAINLESS STEEL, SATIN NICKEL OR SATIN ALUMINUM. • EXIT HARDWARE SHALL BE COMPLIANT WITH APPLICABLE CODE. • ALL DOOR PULLS AND LOC:<5ET5 TO BE COMMERCIAL GRADE SATIN STAINLESS STEEL FINISH BY SCHLAGE, D SERIES /RH0DE5 OR EQUAL. • ALL DOORS, JAMBS, I CEILINGS TO BE PAINT GRADE PAINTED SEMI-GLOSS UNLESS OTHERWISE SPECIFIED. v ALL INTERIOR 1- 4ARDWARE 15 TO BE LEVER TYPE OR APPROVED EQUAL FOR DISABLED ACCESS. TH15 INCLUDE5 DOORS AND 51NK5. THE BOTTOM 10" INCHES OF ALL DOORS (EXCEPT .AUTOMATIC AND SLIDING) SHALL NAVE A SMOOTH UNINTERRUPTED 5URFACE OR SHALL BE PROVIDED WITH 10 - INCH 1 SMOOTH METAL PANEL AT THE BOTTOM TO ALLOW THE DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS CONDITION. (PER APPLICABLE CODE). 0 W � sill h Q i _E 444 pry, a r- 04 Mal �alo w rn moo e� dai Ms u Q 3 � v�. C4 on r4 V a» IL+ rA F m C4 s ■ ■ m ~ ORCOECT DATE 04m.m 01/01/04 DRAWN C►+ECNfD Lr 9 R"SEC I op u APR - 1 2004 CIETAU AM s►� t A -5 A THE MAXIMUM FLAME SPREAD CL-ASS OF FINISH MATERIALS USED ON INTERIOR WALLS AND CEILINGS SHALL NOT EXCEED THAT SET FORTH i r -, . , i . ! I IT i_uiit TESTING SHALL BE MADE BY AN APPROVED TESTING AGENCY TO ESTABLISH SURFACE -- BURNING CHARACTERISTICS AND TO SHOW THAT MATERIALS WHEN CEMENTED OR OTHERWISE FASTENED IN PLACE WILL NOT READILY BECOME DETACHED WHEN SUBJECTED TO ROOM TEMPERATURES OF 300 DEGREES FOR 25 MIN. CLASSES OF MATERIALS BASED ON THEIR FLAME SPREAD INDEX SHALL BE AS SET FORTH ��02.2 CLASSIFICATION: THE CLASSES OF MATERIALS BASED ON THEIR FLAME SPREAD INDEX SHALL BE AS SET FORTH IN TABLE 8 —A. THE SMOKE DENSITY SHALL BE NO GREATER THAN 450 WHEN TESTED IN ACCORDANCE WITH UBC STANDARD 8 -1 IN THE WAY INTENDED FOR USE. of to o ONog*lo �' N ??, I 1 2QQ q.&� 'N i W: v 411 J: mxe� W.T:Tz :03 • A THE MAXIMUM FLAME SPREAD CL-ASS OF FINISH MATERIALS USED ON INTERIOR WALLS AND CEILINGS SHALL NOT EXCEED THAT SET FORTH i r -, . , i . ! I IT i_uiit TESTING SHALL BE MADE BY AN APPROVED TESTING AGENCY TO ESTABLISH SURFACE -- BURNING CHARACTERISTICS AND TO SHOW THAT MATERIALS WHEN CEMENTED OR OTHERWISE FASTENED IN PLACE WILL NOT READILY BECOME DETACHED WHEN SUBJECTED TO ROOM TEMPERATURES OF 300 DEGREES FOR 25 MIN. CLASSES OF MATERIALS BASED ON THEIR FLAME SPREAD INDEX SHALL BE AS SET FORTH ��02.2 CLASSIFICATION: THE CLASSES OF MATERIALS BASED ON THEIR FLAME SPREAD INDEX SHALL BE AS SET FORTH IN TABLE 8 —A. THE SMOKE DENSITY SHALL BE NO GREATER THAN 450 WHEN TESTED IN ACCORDANCE WITH UBC STANDARD 8 -1 IN THE WAY INTENDED FOR USE. of to o ONog*lo �' N ??, I 1 2QQ q.&� EASEL STAND INTERI ELEV SCALE: 1/2" = V -0" DER IRE INTERIOR ELEVATION SCALE: 1/2" = V -0" BRAKE ARM POSITION ON MOUNTINCs MWACrcFZT M;:r_niat= SETTING ON TR4 � NOTE: D O,NOT L IFT ARM ALL THE WAS ' _UP C LEVELER LOCK DETAIL l SCALE N 0 • 6 4 INTERIOR ELEVATION SCALE: 1/2" = V -0" INTE ELE SCALE: 1/2" = 1' -0" NOTE_: A L IBRAKE A '►5 ARE TO_ 5 IN THE LOCKED ED A" TRACK_ MOUNTED UNITS NOTE: CABINETS ARE FOR DISPLAY PURPOSES ONLY. ALL CONSUMER TRANSACTIONS OCCUR AT SALES STATIONS WHICH ARE COMPLIANT WITH TITLE 24 REQUIREMENTS. TRACK T I Co TRACK C 118681(0 ) — MENDING BRACKET l 1 186 813 ; -� -- NO. 8 x 0.62 PAN HEAD SCREW TNROUCsN BOTTOf" HOLE AT END OF TRACK INTO 1"1'END:NG BRACKET T -1 6 TRACK D -- SCALE. N.T.S. - c T -16 TRACK DETAIL NO. 10 x 1 114" TRUSS +4E AD SCREWS ON 17 1/2 "CENTERS. THROUGH ALUMINIUM TRACK INTO STUD AND BLOCKING GYP. BOARD � �RpytD PR 2 � 2Q4� A Y i I � i t: 7 ~ ZF b �� DO 22 L o i 3 • LL„ v� • v� N �y s a w ■ I PPo,kCT 04071.000 DAR 01/01/04 DR AWN LY CHECc•:: �— 1 9 �� +"slo I I � I I APR - 1 2004 i SHf E ''TL E ^1 ElEVAT101� . =T S►�f E' � i N i . r-.. .. .�.... .. .. .. .w... � .- .p.+.. .•.niyy�w.�.��.�yr..,,.... ♦� �w ^+.r�r. .n .w.�y�rw +�� 2x WOOD BLOCKING SCREWED TO STUDS W/ 2" SELF TAPPING 16" O.C. FINE THREA DRYWALL SCREWS CUSTOM • b ._ S ' rl 01 r` /I f1I r\ A r11 f A f f A I I �I BACK ROOM COUNTER SCALE: 3/8" = I' -0" 5 ,_ 3 1, in N (V 1' -4 2 1 -6" C_4" MANAGER'S STATION ELEVATION 5CALE: 3/8" = I' -0" CTRICAL METALLIC TUBING (EMT) ONLY. UNDERSIDE OF FLOOR OR SIZE (01A.) L(MAX HEIGHT) 1/ 211 41-001 ` 2 / 11 3/4 5 1 1 11 6 1_ rill SETTING TUBE. , SEE MAX. HEIGHT SCHEDULE. 211 121 -711 /'� 2 -1/2 1fv 1_G11 3 " 20 1 .2 11 4 26 -0" 0 ls� NOTES INSTALL BOLT TO SECURE TUBE TO THE OTHER TUBES SHALL LAP ONE- ANOTHER 4" MIN. IN FULLY EXTENDED POSITION. STRUTS OTHER THAN E,M.T. MAY REQUIRE ' ENGR. CALCULATION NOTES (1) 1/4 THE LENGTH OF THE END RUNNER WHICHEVER 15 LEAST. (2) NAILS is ENDS OF HORIZ. STRUTS ARE TO BE PLACED W/ NAIL HEAD TOWARD q OF SPAN OF 5TRUT. 12 GA. HANGER WIRE MILL 'l 71,0 1 M 71 WILIA NOTES 1. ALL 2'X4' L6HT FIXTURE 4 2'X2' HVAC AIR REGISTERS SHALL BE SUPPORTED BY 12 G HANGER WIRES WITHN 3" OF EACH CORNER AND TWO (2) HANGER WIRES (SLACK) AT DIAGONAL CORNERS, CEILING SYSTEM SHALL NOT SUPPORT OTHER ITEMS. 2. WIRES TO PEDANT MOUNTE FIXTURES SHALL BE 9 GUAGE AND FIX TURE5 SHALL BE INDEPENDANTL SUPPORTED BY BUILDING STRUCTURES _ CROSS RUNNER Ar-MATIr'AI PANFI TYPICAL: 12 GA. VERTICAL HANGER WIRE 0 4' -0" EA. WAY W/ MIN. 3 TIGHT TURNS IN 1 1/2" BOTH ENDS OF WIRE INSTALL COMPRESSION STRUT a 12' -0" EA. DIRECTION OR EVERY 144 5F. OF CEILING AREA PER UBC 5TD, 41 -18 LOCATE 6 SPLAY WIRE LOCATION SEE Al -1 _I2 GA. SPLAY WIRE 612' -0" CC EA WAY W/ MIN 4 TIGHT TURNS IN 11/2" BOTH ENDS OF WIRE. INSTALL IN 4 DIRECTIONS 0 90' ANGLE TO EACH, TYPICAL TYPICAL: 3/4" X 3/4" ANGLE BRACE * 45 DEGREE ANGLE. TYPICAL: 12 GA. ATTACH TO FLOATING GRID 4 VERTICAL WIRE AND STATIONARY GRID WITH 4' EA. WAY 1/2" X 0 12 SELF - TAPPING SCREW. —, AP "VID R 2 � zooa p,P MAIN RUNNER 2' O.G. TO RECE I vE NEW ARMSTRONG CEILING. DETAIL @ ACCENT CEILIN GRO55 RUNNER SCALE N.T.S. COMPRESSION STRUT RUNNER TEE5 FIRST WIRE - NO. 12 GAUGE WIRE HANGERS AT 4' -0" O.C. EACH WAY. 4 NO. 12 WIRES SPLAYED 45 degrees IN 4 DIRECTIONS SO degrees APART. MAX MA WALL 6 _U 7�._pO» i ,_0p» 6 *--0» MAX. 1`1ASc. MAX NOTE: COMPLIES LOTH UBC 25 -2: SEE SHEET 4- 5`DE7AIL A FOR 51=ECIFICATION INFO. 4 DETAIL 5 @ ACCENT CEILING MAIN ' » T`'AICAL: 3'4" 2'_ 4�'0» r BRACE • 45 DEGREE 4NG,_E. �— RUNNER it 2 CROSS RIANER `�"C, » �` ,-' A "AC:w TO FLOAT GR ^ 4 C C 'C 24' - :11 (M AX.) FROM BRACING `� 04 3TAT GRID w RECE /E NE,, WIRES TO C ,055 RANKERS 1 X 91 2 SELF- TAPP'NG SGREw - +R? CE _ ING : 6) CXTAL �AC�T _ � DETAL @ ACCENT CEO SCALE N.T.S. SCALE N. - 'r .s 4 •r MAIN RUNNER CRO55 RUNNER DETAIL @ ACCENT CEILING 7 SCALE N.T.S. 12 GA. HANGER WIRE MIN. 3 TIGHT TURNS AT TOP " c„ AND BOTTOM OF WIRE. MAX. - MAIN OR CROSS RUNNERS $ MAX. OTE (1) - OR NOTE (1) HORIZ. SPACER BAR W/ HORIZ. 6d RING SHANK NAIL (SEE NOTE 2) ALTERNATE LOCATION WITHOUT NAIL NOTCHING PERMITTED ONLY --�—* is RWVER ACOUSTICAL PANEL FOR RIVET a ALL MEMBERS ONE WALL (NO RIVET) PERIMETER MEMBER * STARTER 4 OPP. WALLS MTL. ATTACHMENT - 1 1 " MIN. EMBEDMENT, OPPOSITE WALLS Ll z all, v z a NQ it F 4" + E M � Ira; » ,5 IFS a ail n Ip p, � z o �,_ ��o H a� v 3 W. c in o ILI I� IOWA a O z, H � T ,A*r 01072.000 01/01/04 (1QAMN LY 9 I QE - v+SED %R I v APR - 1 2004 11 cEmm UNDERSIDE OF FLOOR OR ROOF STRUCTURE ABOVE. MTAU NO. 12 GA. VERTICAL WIRE HAWGER, TRUE CEILING GRID LEVEL PRIOR TO SETTING TUBE. , SEE MAX. HEIGHT SCHEDULE. DRILL 5/32" HOLE IN 4 INSTALL 1/8" BOLT 4 LOCK- ING NUT. EMT. SLEEVE - ' SLOT CUT. 4 •r MAIN RUNNER CRO55 RUNNER DETAIL @ ACCENT CEILING 7 SCALE N.T.S. 12 GA. HANGER WIRE MIN. 3 TIGHT TURNS AT TOP " c„ AND BOTTOM OF WIRE. MAX. - MAIN OR CROSS RUNNERS $ MAX. OTE (1) - OR NOTE (1) HORIZ. SPACER BAR W/ HORIZ. 6d RING SHANK NAIL (SEE NOTE 2) ALTERNATE LOCATION WITHOUT NAIL NOTCHING PERMITTED ONLY --�—* is RWVER ACOUSTICAL PANEL FOR RIVET a ALL MEMBERS ONE WALL (NO RIVET) PERIMETER MEMBER * STARTER 4 OPP. WALLS MTL. ATTACHMENT - 1 1 " MIN. EMBEDMENT, OPPOSITE WALLS Ll z all, v z a NQ it F 4" + E M � Ira; » ,5 IFS a ail n Ip p, � z o �,_ ��o H a� v 3 W. c in o ILI I� IOWA a O z, H � T ,A*r 01072.000 01/01/04 (1QAMN LY 9 I QE - v+SED %R I v APR - 1 2004 11 cEmm ,i ADJACENT WALLS MTAU A�7 r ,i ADJACENT WALLS r PANEL 'A' M /120 -MOLT, 3-PHASE, 4 -WIRE 225 -AMP MAIN LUG DESCRIPTION FI=RE LOAD T P POLE CASH REGISTER &>jM& E (NOT ALL FIXTURES USED) KEYED NOTE 10 1 REF LOAD BREAKER NO AMPS P AMP 9.0 1 20 LOAD TYPE R NOTES: EXISTING PANELBOARD WITH 200 -AMP FEEDER BY LANDLORD. PROVIDE NEW PANELBOARD COVER. PHASE AMPS LOAD LOAD REF KEYED A 6 C TYPE AMPS NO NO TE 15.0 R 20 1 6.0 101 LOAD DESCRIPTION AEC - CAT S DATA HUB CKT NO 2 3 REC - T P POLE CASH REGISTER TYPE 101 1 9.0 1 20 R 62 15.0 RECESSED R 20 1 6.0 SHEET E -3, KEYED NOTE J6. 101 REC - SUPPORT SHIES CASH REGISTER 4 5 REC - SUPPORT PRE -PAID 2 101 2'x4' RECESSED LIGHT AND BATTERY PACK 9.0 1 20 R RECESSED "METAL.UX" 2GR8232A- UNV -EB81 EMERGENCY BALLASTS - IOTA 124 15.0 R 20 1 6.0 101 FUSIBLE DISCONNECT SWITCH, SIZE AS NOTED REC - CONSUMER 6 7 REC - CASH REGISTER EXISTING 101 LARGEST MOTOR 4.5 1 20 R 9.0 3 W R 20 1 4.5 2 101 120 REC - SALES AREA 8 9 REC - SALES AREA 2. DEVICE AND COVERPLATES COLOR PER NOTES 1 AND 2 ABOVE. SEE 101 ELECTRONIC BALLASTS 6.0 1 20 R 4g ISOLATED GROUND MARE 11.6 FOR CLARITY, WIRING MARKS ARE 94OWN ON THE HOMERUN ONLY. L 20 1 5.6 2 100 120 T- MOBILE SIGN 10 11 LIGHTS & REC - WINDOW DISPLAYS 101 2.8 1 20 W 5 5.8 R 20 1 3.0 RECESSED 101 REC - DESK 12 13 LIGHTS - SALES BACK ROOM 101 8.8 1 20 L 11.8 3 R 20 1 3.o 100 AEC - BACK ROOM 14 15 TRACK LIGHTS EXIT LIGHT UNIVERSAL RED FACE 101 16.0 2 20 T 17.5 "JUNO" 2- CIRCUIT, TRAC -LITES R 20 1 1.5 101 120 REC - MICROWAVE 16 17 TRACK LIGHTS 101 1 16.0 + ++ T 19.0 R 20 1 3.0 101 REC - RERRWERATOR 18 19 REC - DESK /TRAINING 101 6.0 1 20 R 41.0 A 40 3 35.0 100 C UNIT 20 21 BLANK "METALUX" CR- 232 -A- 120 -EB81 ELECTRONIC BALLASTS FLU. 32W 2 62 35.0 SURFACE A ++ + 35.0 100 C UNR 22 23 BLANK 1'x4' SURFACE WRAP AND FLU. 32W 2 62 120 SURFACE "METALUX" CR- 232 -A- 120 -EB81 EMERGENCY BALLAST - 10DA 124 35.0 A •+ + 35.0 100 C UNIT 24 251 0.0 26 27 0.0 28 29 0.0 30 31 0.0 32 33 0.0 34 35 0.0 36 37 0.0 38 39 0.0 40 41 0.0 42 PANEL TOTALS: 1 77 1 79 1 75 1 5% DIFFERENCE 03126104 N.E.C. DEMAND CALCULATION LIGHTING AN OTHER CONTINUOUS LOAD: TRACK LIGHTING: SHOW WINDOWS: RECEPTACLE LOAD: KITCHEN EQUIPMENT LOAD: HEATING (COINCIDENTAL) LOAD: MOTORS AND OTHER NON - CONTINUOUS OR MISCELLANEOUS LOAD: LARGEST MOTOR LOAD: TOTALS: ACTUAL ANA 1.7 3.8 0.3 9.2 0.0 0.0 8.3 4.3 27.7 DEMAND FACTOR 125% N/A N/A 1002 100% 100% 100% 1252 119% DEMAND KVA 2.2 3.8 4.0 9.2 0.0 0.0 8.3 5.4 32.9 ExNudes track and show window lighting. Length of track: 24 ft Length of show window: 20 ft 1 00% of the first 10 WA. plus 50% over 10 WA. Booed on 0 piece(s) of equipment. Includes space heat in excess of cooling and other electric hoot. AN other hods excluding longest motor lood. MINIMUM 3 -PHASE FEEDER: 92 -AMPS FWTM &>jM& E (NOT ALL FIXTURES USED) TYPE SYMBOLS DESCRIPTION LAMP WATT VOLT MOUNTING MANUFACTUER & MODEL TYPE N0. 1 2'x4' RECESSED LIGHT W/ ELECTRONIC BALLASTS FLU. 32W 2 62 120 RECESSED "METALUX" 2GR8232A- UNV -EB81 W /SYL F032/735 WHIPS 4 -PLEX WALL MOUNTED JACK FOR CASH PODS AND PRODUCTS ISLAND, REFER TO SHEET E -3, KEYED NOTE J6. ZS P.O.S DATA OUTLET WITH 3/4" CONDUIT TO DATA TERMINAL. 15" A.F.F. = TELEPHONE OUTLET WITH 3/4" CONDUIT TO TELEPHONE BACKBOARD. 15" A.F.F. 2 2'x4' RECESSED LIGHT AND BATTERY PACK FLU. 32W 2 62 120 RECESSED "METAL.UX" 2GR8232A- UNV -EB81 EMERGENCY BALLASTS - IOTA 124 PANELBOARD CIRCUIT BREAKER EP FUSIBLE DISCONNECT SWITCH, SIZE AS NOTED W /SYL F032/735 LAMPS NON- FUSIBLE DISCONNECT SWITCH, SIZE AS NOTED (E) EXISTING LM LARGEST MOTOR (N) NEW A.F.F. ABOVE FINISHED FLOOR FLA 3 W WATTS ML 2'x2' RECESSED LIGHT W/ FLU. 32W 2 62 120 RECESSED "LIGHTOLIER" DPA2G9LS2U6 -120 NOTES 1. SUBSCRIPT LETTER NEXT TO THE ABOVE SYMBOLS. INDICATES DEVICE CONTROLLED. 2. DEVICE AND COVERPLATES COLOR PER NOTES 1 AND 2 ABOVE. SEE ARCHITECTURAL DRAWING FOR EXACT LOCATIONS OF OUTLETS, UNLESS NOTED. ELECTRONIC BALLASTS EXTERIOR LOCATIONS SHALL BE GROUNDED FAULT TYPE (GFI). 4. DASHED LINE TYPE INDICATES EXISTING CONDITIONS. UNGROUNDED CIRCUIT WIRE. (HOT) GROUNDED CIRCUIT MARE. (NEUTRAL) 4g ISOLATED GROUND MARE W /SYL F8032 /735 /ECO LAMPS FOR CLARITY, WIRING MARKS ARE 94OWN ON THE HOMERUN ONLY. 4 RUN TO THE FINAL CONNECTION OF ANY DEVICE SERVED. 2'x2' RECESSED LIGHT AND BATTERY PACK FLU. 32W 2 62 120 RECESSED "LIGHTOLIER" DPA2G9LS2U6 -120 EMERGENCY BALLAST - IOTA 124 w /SYL F8032 /735 /ECO LAMPS 5 RECESSED DOWNLIGHT W /SPECULAR CLEAR ALZAK FLU. 32W 1 37 120 RECESSED "CAPRI"CM6 /FV26/32/42U/V65 REFLECTOR W /SYL CF32DT /E /IN/ 835 LAMPS 6 EXIT SIGN W /BATTERY LED 3 120 CEUNG OR "SUREUTE" LPX70RWH LED BACK -UP WALL. EXIT LIGHT UNIVERSAL RED FACE TRACK LIGHT FIXTURE WITH "JUNO" 2- CIRCUIT, TRAC -LITES 7 TRACK (LENGTH AS SHOWN) 5O/FT 120 CEILING TRAC SYSTEM, 'JUNG' T620WH WITH 5OPAR20 /HAL /SPL /NFL/ RP -120 LAMP AL A& If F9ft f v run M 9 1'x4' SURFACE WRAP W/ "METALUX" CR- 232 -A- 120 -EB81 ELECTRONIC BALLASTS FLU. 32W 2 62 120 SURFACE l� EQUAL) W /SYL F032/735 10 1'x4' SURFACE WRAP AND FLU. 32W 2 62 120 SURFACE "METALUX" CR- 232 -A- 120 -EB81 EMERGENCY BALLAST - 10DA 124 BATTERY PACK (OR EQUAL)W /SYL F032/735 LAMPS SYMBOLS AM NOTES SYMBOLS DESCRIPTION $ SINGLE POLE TOGGLE SWITCH, 20 AMP, 120V. 36" A.F.F. $Z DOUBLE PLOE, SINGLE THROW SWITCH 20 AMP, 120V. 36" A.F.F. $3 THREE WAY SWITCH, 20 AMP, 120V. 36" A.F.F. $m MOTOR RATED SWITCH, H.P. RATED. 36" A.F.F. TELE /POWER POLE WITH DEVICES AS INDICATED SINGLE RECEPTACLE, NEMA RATING A NOTED $ DUPLEX RECEPTACLE, 20 AMP, 120V GROUNDING TYPE, =(:�: I.G. TYPE =0: DOUBLE DUPLEX RECEPTACLE, 20 AMP, 120V GROUNDING TYPE, 40 I.G. TYPE A CEILING MOUNTED DUPLEX RECEPTACLE, SAME AS ABOVE 4 -PLEX WALL MOUNTED JACK FOR CASH PODS AND PRODUCTS ISLAND, REFER TO SHEET E -3, KEYED NOTE J6. ZS P.O.S DATA OUTLET WITH 3/4" CONDUIT TO DATA TERMINAL. 15" A.F.F. = TELEPHONE OUTLET WITH 3/4" CONDUIT TO TELEPHONE BACKBOARD. 15" A.F.F. FLOOR TYPE DUPLEX RECEPTACLE, 20A GROUNDING TYPE SPECIAL PURPOSE OUTLET OR DIRECT CONNECTION M UTIUTY METER MOTOR OR CEILING EXHAUST FAN JUNCTION BOX TO SUIT THE FIELD CONDITIONS PANELBOARD CIRCUIT BREAKER EP FUSIBLE DISCONNECT SWITCH, SIZE AS NOTED Q� NON- FUSIBLE DISCONNECT SWITCH, SIZE AS NOTED (E) EXISTING LM LARGEST MOTOR (N) NEW A.F.F. ABOVE FINISHED FLOOR FLA FULL LOAD AMPS W WATTS ML MOTOR LOAD A AMPS LCL LONG CONTINUOUS LOAD NOTES 1. SUBSCRIPT LETTER NEXT TO THE ABOVE SYMBOLS. INDICATES DEVICE CONTROLLED. 2. DEVICE AND COVERPLATES COLOR PER NOTES 1 AND 2 ABOVE. SEE ARCHITECTURAL DRAWING FOR EXACT LOCATIONS OF OUTLETS, UNLESS NOTED. 3. RECEPTACLES IN BATHROOMS, LAUNDRY ROOMS, AND KITCHEN SINK AND EXTERIOR LOCATIONS SHALL BE GROUNDED FAULT TYPE (GFI). 4. DASHED LINE TYPE INDICATES EXISTING CONDITIONS. UNGROUNDED CIRCUIT WIRE. (HOT) GROUNDED CIRCUIT MARE. (NEUTRAL) 4g ISOLATED GROUND MARE GROUND WIRE FOR CLARITY, WIRING MARKS ARE 94OWN ON THE HOMERUN ONLY. CONTRACTOR SHALL MAINTAIN THE CONDUCTOR QUANTITY THROUGHOUT THE RUN TO THE FINAL CONNECTION OF ANY DEVICE SERVED. NO7'E8: I. ALL RECEPTACLES AND SWITCH COVERPUIES ON P1 FINISH SHALL BE WHITE. 2. ALL RECEPTACLES AND SWITCH COVERPLATES ON P2 FINISH SHALL BE BLACK. 3. LIGHT SWITCH AND POSITION AND CIRCUIT ALLOCATION TO BE DETERMINED, MOUNT All SWITCHES 448 O.C. A.F.F. SPECIFICATIONS I. THE ELECTRICAL DRAWINGS, SPECIFICATIONS AND GENERAL NOTES DESCRIBE THE RECOMMENDED SCOPE OF WORK AND SHALL BE USED FOR THE PURPOSE OF BIDDING, BUILDING DEPARTMENT REVIEW AND TO SECURE THE NECESSARY CONSTRUCTION PERMIT ONLY. CONTRACTOR SHAD. PROVIDE CONSTRUCTION DRAWINGS AND OBTAIN WRITTEN APPROVAL OF ALL INSPECTION AGENCIES AND UTILITY COMPANIES PRIOR TO START OF WORK. 2. THE ELECTRICAL DRAWINGS, CONDUIT RUNS, WIRING, LIGHTING FIXTURES AND DEVICE LOCATIONS ARE DIAGRAMMATIC ONLY. DO NOT SCALE THE ELECTRICAL DRAWINGS TO DETERMINE THE LOCATION OF EQUIPMENT, LIGHTING FIXTURES, DEVICES OR OUTLETS. 3. REFER TO THE ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATION OF ALL LIGHTING FIXTURES, CEILING MOUNTED OUTLETS AND EQUIPMENT. 4. COORDINATE THE PLACEMENT AND MOUNTING HEIGHT OF ALL DEVICES WITH THE ARCHITECTURAL DRAWINGS ELEVATIONS PRIOR TO ROUGH -IN WORK. 5. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FURNISH APPROVED LIGHTING FIXTURES OF THE TYPE REQUIRED FOR MOUNTING IN RELATED CEIUNGS. PROVIDE FIXTURES COMPLETE WITH NECESSARY MOUNTING HARDWARE AND ACCESSORIES. 6. PORTIONS OF THE CEILING SYSTEMS MAY BE INACCESSIBLE. THEREFORE, THE CONTRACTOR SHALL STRATEGICALLY LOCATE ALL JUNCTION BOXES IN AN ACCESSIBLE CEILING SPACE. ALL LIGHTING FIXTURE WIRING, BALLASTS, J- BOXES, ETC. SHALL BE ACCESSIBLE FROM FIXTURE OPENING. 7. MAKE ALL FINAL CONNECTIONS TO OWNER FURNISHED EQUIPMENT, UNLESS OTHERWISE NOTED. VERIFY ELECTRICAL CHARACTERISTICS AND UL LISTING PRIOR TO CONNECTION. 8. ELECTRICAL OUTLETS ON OPPOSITE SIDES OF FIRE -RATED WALLS AND PARTITIONS MUST BE SEPARATED BY DISTANCE OF 24 IN. HORIZONTAL. 9. PROVIDE AN ADDITIONAL JUNCTION BOX (SIZE AS REQUIRED) WHERE THE NUMBER OF CONDUCTORS EXCEEDS THE MAXIMUM ALLOWED FOR A GIVEN JUNCTION POINT OR OUTLET. 10. CONDUCTORS SHALL BE COPPER THHN/THWN 600 VOLT INSULATION UNLESS OTHERWISE NOTED. USE PROPER TEMPERATURE RATING OF CONDUCTORS BASED ON THE AMBIENT AIR TEMPERATURE WHERE CONDUCTORS ARE BEING USED. HIGH AMPACITY CONDUCTOR AND LARGER RACEWAY SHALL BE PROVIDED TO OFFSET THE AMPACITY CORRECTION FACTORS AS INDICATED IN NEC TABLE 310 AND ELSEWHERE PER CODE. 11. ALL FLUORESCENT BALLASTS AND LAMPS SHALL BE ENERGY SAVING TYPE. 12. SEAL ALL PENETRATIONS THROUGH FIRE RATED WALLS, CEILINGS, FLOORS. ETC., TO MAINTAIN THE FIRE RATING. FURNISH AND INSTALL FIRE RATED ENCLOSURE FOR ALL EQUIPMENT PENETRATING INTO FIRE RATED ENVELOPES, SPACES, ETC. 13. ALL ELECTRICAL EQUIPMENT SHALL BE BRACED OR ANCHORED TO RESIST A HORIZONTAL FORCE ACTING IN ANY DIRECTION USING THE FOLLOWING CRITERIA. v) FIXED EQUIPMENT ON GRADE 33% OF OPERATING WEIGHT. b) FIXED EQUIPMENT ON STRUCTURE 50% OF OPERATING WEIGHT. c) FOR FLEXIBLE MOUNTED EQUIPMENT, USE 2 TIMES THE ABOVE VALUE. d) SIMULTANEOUS VERTICAL FORCE - USE 1/3 TIMES HORIZONTAL FORCE. 14. ALL EXISTING CONDITIONS ARE NOT INDICATED ON THE DRAWINGS. CONTRACTOR SHALL CAREFULLY EXAMINE THE EXISTING INSTALLATION AND ALL PROJECT DRAWINGS TO BECOME FAMILIAR WITH THE SCOPE OF WORK. NO ADDITIONAL CHARGES WILL BE ALLOWED DUE TO THE LACK OF A PRE -BID SITE EXAMINATION. 15. CONDUIT, WIREWAYS, ETC., SHALL BE BRACED IN ACCORDANCE WITH SMACNA. 16. ALL FIXTURES TO BE INSTALLED PER UBC SECTION 2804. FIXTURE SUPPORT BY NO. 12 GAUGE HUNGERS ATTACHED TO GRID MEMBERS WITHIN THREE INCHES OF EACH CORNER OF EACH FIXTURE. 17. LIGHTING FIXTURES AND CONDUITS SHALL BE SUPPORTED DIRECTLY BY WIRES TO THE STRUCTURE ABOVE. EXCEPTION: RECESSED LIGHTING FIXTURES NOT OVER 56 LBS. IN WEIGHT AND SUSPENDED OR PENDANT HUNG FIXTURES NOT OVER 20 LBS. IN WEIGHT MAY BE SUPPORTED AND ATTACHED DIRECTLY TO THE CEILING SYSTEM RUNNERS BY A POSITIVE ATTACHMENT SUCH AS SCREWS OR BOLTS. AIR DIFFUSERS WHICH WEIGH NOT MORE THAN 20 LBS. AND WHICH RECEIVE NO TRIBUTARY LOADING FROM DUCTWORK MAY BE POSITIVELY ATTACHED BY THE CEILING RUNNERS. THE ABOVE REQUIREMENTS ARE BASED ON UBC STANDARD 25 -2. OTHER METHODS MAY BE USED, PROVIDED THEY ARE SUBSTANTIATED BY DESIGN CALCULATIONS USING THE LOADS SPECIFIED IN CHAPTER 25. THE APPROVED BUILDING PLANS SHALL CLEARLY IDENTIFY ALL ELEMENTS AND SHOW ALL DETAILS OF THE BRACING SYSTEMS. 18. BRANCH CONTROL CIRCUITING AND WIRE COUNT MAY NOT BE INDICATED ON THESE PLANS. CONTRACTOR IS RESPONSIBLE TO COMPLETE THE BRANCH CIRCUIT WIRING IN ACCORDANCE WITH PLAN NOTES AND AS PERMITTED BY AUTHORITY. CONTRACTOR SHALL SUBMIT AS -BUILT DRAWINGS AS A PART OF RECORD DRAWING SUBMITTAL TO ARCHITECT AND AUTHORITY HAVING JURISDICTION (AHJ). 19. THE ELECTRICAL INSTALLATION SHALL COMPLY WITH THE NATIONAL ELECTRICAL CODE (NEC) ADOPTED BY THE JURISDICTION AND INCLUDING ANY LOCAL SUPPLEMENTS. 20. THE ELECTR INSTALLATION WORK SHALL COMPLY WITH ALL LOCAL, STATE AND NATIONAL CODES, LAWS AND ORDINANCES APPLICABLE TO ELECTRICAL WORK. 21. ALL MATERIAL AND EQUIPMENT FURNISHED AND INSTALLED UNDER THIS CONTRACT SHALL BE FREE FROM DEFECTS, AND SHILL BE GUARANTEED FOR A PERIOD OF ONE YEAR FROM DATE OF FINAL ACCEPTANCE BY OWNER OR HIS REPRESENTATIVE. 22. ALL WORK TO BE EXECUTED IN WORK MANLIKE MANNER AND SHALL PRESENT A NEAT MECHANICAL APPEARANCE W 14EN COMPLETED. 23. REMOVE AND DISPOSE OF ALL UNUSED OR ABANDONDED CONSTRUCTION MATERIALS. 24. METAL CLAD CABLE SHALL BE PERMITTED FOR BRANCH CIRCUITING PER NEC. 25. IT SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO VERIFY ALL EXISTING LIGHT FIXTURES, DEVICES AND EQUIPMENT SCHEDULED FOR REMOVAL, AND DISCONNECT AT THEIR POWER SOURCE PRIOR TO ANY DEMOLITION WORK. THE CONTRACTOR SHALL TAKE ALL PRECAUTIONARY MEASURES NECESSARY TO ELIMINATE ANY ELECTRICAL HAZARDS THAT MAY ARISE DURING THE DEMOLITION PHASE OF WORK. 26. THE ELECTRICAL CONTRACTOR SHALL VERIFY AND INSPECT ALL EXISTING CONDITIONS AND ELECTRICAL EQUIPMENT AND MAKE ALL NECESSARY MODIFICATIONS AND /OR ADJUSTMENTS AS REQUIRED FOR THE PROPER OPERATION OF EQUIPMENT AND COMPUANCE WITH ALL APPLICABLE CODES. 27. ALL DEVICES AND COVERPLATES SHALL BE DECOR TYPE. 28. ALL CONDUITS SFIALL CONTAIN AN EQUIPMENT GROUND CONDUCTOR, SIZE IN ACCORDANCE WITH ARTICLE 250 OF THE NEC. PLRMIT AND APPROVAL REQUIRED A t =6 a I L � 100 EXISTING CIRCUIT TO REMAIN. 101 REMOVE EXISTING CIRCUIT AND RE -USE BREAKER FOR NEW CIRCUIT AS SHOWN. W ,&. A a • i r 1/2 3 #12:A -11,13 1 #12:GND - i; I� ;c �I 1 F Yk 1 1a 1 S 1/2"c 3# 12:A -15,17 1 # 12:GND UGHTM PLAN r c_z _: "T "as --I TZ A. THE ELECTRICAL CONTRACTOR SHALL ADJUST, RELOCATE, OR PROVIDE NEW FIXTURES AS REQUIRED TO ACCOMMODATE NEW CONSTRUCTION. PROVIDE AND INSTALL JUNCTION BOXES, FITTINGS, CONDUITS AND WIRING AS NECESSARY FOR A COMPLETE INSTALLATION IN COMFORMANCE WITH THE NATIONAL ELECTRIC CODE AND OTHER LOCAL CODES. THE ELECTRICAL. CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS AND INSPECTIONS REQUIRED. COORDINATE ELECTRICAL REQUIREMENTS AND CONDUIT ROUTING WITH OTHER TRADES. B. THE ELECTRICAL CONTRACTOR SHALL VERIFY ELECTRICAL LOADS ON EXISTING CIRCUIT(S) AND PANELBOARD(S) PRIOR TO MAKING ANY MODIFICATIONS TO ENSURE ADEQUATE CAPACITY FOR NEW DEVICES AND LIGHT FIXTURES. PROVIDE AND INSTALL CIRCUIT BREAKERS OF THE SAME TYPE AND RATING IN THE EXISTING PANELBOARD(S). C. CONTRACTOR SHALL COORDINATE LOCATIONS OF RECEPTACLES AND VOICE /DATA RECEPTACLES TO BE INSTALLED WITH TENANT. MOUNT CONVENIENCE RECEPTACLES AND VOICE /DATA RECEPTACLES AT 18" ABOVE FINISHED FLOOR. MEASUREMENTS SHALL BE TO THE CENTER OF BOX. D. FINAL ELECTRICAL MODIFICATIONS ARE TO BE COORDINATED WITH GENERAL CONTRACTOR, io POSITION OF ALL ELECTRICAL CONTROL DEVICES, SWITCHES, ALARM SENSORS, SECURITY CAMERAS, THERMOSTATS, TELEPHONE JACKS, ETC. E. PROVIDE EMPTY CONDUIT FROM VOICE /DATA JUNCTION BOX WITH PULLSTRING TO ACCESSIBLE SPACE ABOVE CEILING. F. WHERE DEMOLITION OF EXISTING DEVICES OCCURS, THE CONTRACTOR SHALL REMOVE CONDUIT AND WIRE BACK TO NEAREST UP— STREAM DEVICES OR JUNCTION BOX. INTERCEPT AND EXTEND EXISTING CIRCUITS TO DOWSTREAM DEVICES SO THEY REMAIN OPERATIONAL.. G. EXISTING ELECTRICAL DEVICES TO REMAIN AND BE PROTECTED, UNLESS OTHERWISE NOTED. H. COORDINATE WITH MECHANICAL CONTRACTOR AND PROVIDE POWER AS REQUIRED TO MECHANICAL UNITS. I. COORDINATE WITH THE LANDLORD— TENANT AGREEMENT TO ENSURE COMPLIANCE WITH THE ELECTRICAL REQUIREMENTS FOR TENANT'S CONSTRUCTION WORK. s KEYED NOTE& (nxs SHEET ONLY) 2. EXISTING nweaocK FOR ca+rna OF r -MOBILE spa+. 3. PROVIDE AND INSTALL SPST, 120V. TOGGLE SWITCHES TO CONTROL FRONT END LIGHTING AS FOLLOWS: = GENERAL LIGHTING = TRACK LIGHTS = DAYLIGHT TRACK = WINDOW DISPLAY LIGHTING (LABEL EACH SWITCH) 4. CONNECT TO T— MOBILE SIGN. PROVIDE CONNECTION FOR EACH SIGN, LETTER, OR LOGO. 5. VERIFY AND RE —USE EXISTING CIRCUIT AND ROUTE VIA THE T— MOBILE SIGN TIME CLOCK LOCATED ADJACENT TO PANEL. W. nrr r � r+ 7. CONNECT EXHAUST FAN TO THE SWITCHED LEG OF THE CIRCUIT SO THAT THE FAN OPERATES WHEN LIGHT IS ON. NOtr NQ� MW 11=0 1 ANO IN , NOR , ;GWA FOR 609— r n n 12. FURNISH AND INSTALL. BLOCKING FOR SURFACE MOUNTING OF FIXTURE TO THE WIRE CEILING OF THE CAGE. 13. CONNECT BATTERY TO "HOT" SIDE OF SWITCH. PARATE PFRMIT AND liz QUIRED r % • a 1 - ..� raw .r...a..ti• .. a T ... r. - ...n ...n .. - .. 2 CAT 5 DATA HUB RE: E -3 -2 FOR 1/2 LAYOUT REQUIREMENTS ; 2112:A-2 , I 1 #12:GND i f 3 4 1 /2 "C - 3# 12:A -16,18 1 #I2:GND 1 / 3# 12:A -1 3 - 1 2 C � 6 f ! r; 4# 12:A - 5,7,9 1/2-C" _ 1 12:GND I l -�' �� -�- 4#1$:4,6,8 f • 1 # 12:GND E.i 9 7 c wis- l9 3 f , _6. : r I -- - -- - - - --- - ---- - ___ v 1 POWER PLAN 6 1 r L (E)PANEL 'A' 1/20'C 2#' 12:A -12 6 2#12:A-19 1_#l2:GN0 _ f :a ,.1' I 3 s � �` i1. i �i a 7 I A. THE ELECTRICAL CONTRACTOR SHALL ADJ UST, RELOCATE, OR PROVIDE NEW FIXTURES AS REQUIRED TO ACCOMMODATE NEW CONSTRUCTION. PROVIDE AND INSTALL JUNCTION BOXES, FITTINGS, CONDUITS AND WIRING AS NECESSARY FOR A COMPLETE INSTALLATION IN COMFORMMNCE WITH THE NATIONAL ELECTRIC CODE AND OTHER LOCAL CODES. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS AND INSPECTIONS REQUIRED. COORDINATE ELECTRICAL REQUIREMENTS AND CONDUIT ROUTING WITH OTHER TRADES. B. THE ELECTRICAL CONTRACTOR SHALL VERIFY ELECTRICAL LOADS ON EXISTING CIRCUIT(S) AND PANELBOARD(S) PRIOR TO MAKING ANY MODIFICATIONS TO ENSURE ADEQUATE CAPACITY FOR NEW DEVICES AND LIGHT FIXTURES. PROVIDE AND INSTALL CIRCUIT BREAKERS OF THE SAME TYPE AND RATING IN THE EXISTING PANELBOARU(S). C. CONTRACTOR SHALL COORDINATE LOCATIONS OF RECEPTACLES AND VOICE /DATA RECEPTACLES TO BE INSTALLED WITH TENANT. MOUNT CONVENIENCE RECEPTACLES AND VOICE /DATA RECEPTACLES AT 18" ABOVE FINISHED FLOOR. MEASUREMENTS SHALL BE TO THE CENTER OF BOX. D. FINAL ELECTRICAL MODIFICATIONS ARE To BE COORDINATED WITH GENERAL CONTRACTOR, is POSITION OF ALL ELECTRICAL CONTROL DEVICES, SWITCHES, ALARM SENSORS, SECURITY CAMERAS, THERMOSTATS, TELEPHONE JACKS, ETC. E. PROVIDE EMPTY CONDUIT FROM VOICE /DATA JUNCTION BOX WITH PULLSTRING TO ACCESSIBLE SPACE ABOVE CEILING. F. WHERE DEMOLITION OF EXISTING DEVICES OCCURS, THE CONTRACTOR SHALL REMOVE CONDUIT AND WIRE BACK TO NEAREST UP- STREAM DEVICES OR JUNCTION BOX. INTERCEPT AND EXTEND EXISTING CIRCUITS TO DOWSTREAM DEVICES SO THEY REMAIN OPERATIONAL. G. EXISTING ELECTRICAL DEVICES TO REMAIN AND BE PROTECTED, UNLESS OTHERWISE NOTED. H. COORDINATE WITH MECHANICAL CONTRACTOR AND PROVIDE POWER AS REQUIRED TO MECHANICAL UNITS. I. COORDINATE WITH THE LANDLORD- TENANT AGREEMENT TO ENSURE COMPLIANCE WITH THE ELECTRICAL REQUIREMENTS FOR TENANT'S CONSTRUCTION WORK. KEYED NOTE& (n«s SHEET ONLY) 1 TELE /POWER POLE WITH 4 -PLEX JACK AND DUPLEX RECEPTACLE FURNISHED BY OWNER, INSTALLED BY CONTRACTOR. PROVIDE AND INSTALL APPROXIMATELY 3' -0" OF SPLIT CORRUGATED INNERDUCT FROM CEILING TO TOP OF POLE FOR CABLE WRAP. 2 CONTRACTOR SHALL FURNISH AND INSTALL 25 PAIR PHONE CABLE FROM MAIN TELEPHONE DEMARCATION LOCATION TO PHONE BOARD. PROVIDE 106 COPPER GROUND IN 1/2" CONDUIT TO PANEL GROUND BAR. 3 MOUNT RECEPTACLE ABOVE COUNTER AND BEHIND MICROWAVE. FIELD VERIFY LOCATION PRIOR TO ROUGH -IN. 4 MOUNT RECEPTACLE ABOVE COUNTER SPLASH PLATE. FIELD VERIFY LOCATION PRIOR TO ROUGH -IN. WT 1=11E 6 STORE — CABLE REQUIREMENTS AS FOB (1) 4 —PLEX JACK AT EACH CASH POD (CASH DESKS NEAR STORE FRONT) (2) 4 -PLEX JACK AT EACH DOUBLE CASH POD (CASH DESKS NEAR STORE FRONT) (2) 4 -PLEX JACK AT EACH SALES SUPPORT COUNTER (WHERE APPLICABLE) (1) 4 -PLEX JACK AT EACH CUSTOMER CARE DESK (WHERE APPLICABLE) (1) 4 —PLEX JACK AT EACH PRODUCT ISLAND (1) 4 —PLEX JACK AT EACH CONSUMER (1) 4 —PLEX JACK AT EACH PROSUMER (1) 4 —PLEX JACK AT EACH RSSK PODIUM (WHERE APPLICABLE) (1) 4 —PLEX JACK IN THE INVENTORY ROOM (1) 4 —PLEX JACK AT THE MANAGER'S DESK /OFFICE. COAXIAL CABLE AS REQUIRED PER THE POWER AND COMMUNICATIONS DRAWING. o) ALL CABLE TO BE 4 PAIR CAT -5E (PLENUM IF REQUIRED BY CODE). b) EACH 4 -PLEX LOCATION, THERE SHALL BE (3) CAT -5E CABLES (PLENUM CABLE IF REQUIRED BY CODE) TERMINATED ON A RJ45 4 - PLEX JACK (ALL JACKS AND PLATES TO BE WHITE.) WIRE /LABEL AT THE PATCH PANEL AND JACK AS FOLLOWS: Wlem (1) —BLANK (I)—VOICE 1 —A (1) — DATA 1 - 8 (1)— BACKUP 1 —C I. CLEARLY MARK EACH AT BOTH THE LOCATION PANEL AND JACK. 2 CAT 2. ALL THREE CABLES TO BE TERMINATED ON A 48 -PORT PATCH PANEL THAT MEETS SPECIFICATIONS REQUIRED BY THE CABLE SUPPLIER TO MEET CAT -5E STMNDARDS. EACH PATCH PANEL MUST HAVE 5 TO 8 EXTRRA PORTS FOR EXPANSION. WALL MOUNT EACH PATCH PANEL WITHIN A SWING -OUT BRACKET ON THE TELEPHONE ROOM'S WALLBOARD. c) DATA PRODUCTS TO BE UTILIZED: FOR FURNITURE: LEVITON QUICKPORT SURFACE MOUNT HOUSINGS MODEL 1 41089 -4WP CONNECTORS: LEVITON GIGAMAX CATEGORY 5e QUICKPORT SNAP —IN CONNECTORS MODEL f 5G108 —RW5 F . LEVITON QUICKPORT SINGLE —GANG WALLPLATES MODEL i 41080 -4WP PATCH . MEL: LEVITON UNIVERAL CATEGORY 5 AND GIGAMAX 5e PATCH PANELS AND PATCH BLOCKS MODEL 1 5G584 --U48 PATCH PANEL BRACKET: LEVITON HINGED WALL -MOUNT BRACKETS MODEL f 49251 -W62 M BERKTEK CAT 5e COPPER CABLE MODEL j LAN - MARK 350 7 REPLACE EXISTING RECEPTACLE AND COVERPLATE. CIRCUIT AS SHOWN. �r"4RATF `.R-MIT AND f REQUIRED a.. . +-. r._ n .. . +. .�,.• _. a.�._.y nw.a..v r -w ..- .�....A�� -aww.. r- i.....�.� . ..» - .. .. v w.. •..r +..., r_ w M •w -..-. • u r+w+•w.M... -r-yn. �.M.w ... .�.n�l.i.w .. ...r.w. - ., rs. w w ...__. -. r r.r. ..-r. a.....�. -_ .- 5 DATA HUB LAYOUT r7