g City of Tukwila
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
DEVELOPMENT PERMIT
Parcel No.: 2623049023
Address: 757 SOUTHCENTER MALL TUKW
Suite No:
Tenant:
Name: T- MOBILE
Address: 1127 SOUTHCENTER MALL, TUKWILA WA
Owner:
Name: JG SOUTHCENTER LTD
Address: 25425 CENTER RIDGE RD, CLEVELAND OH
Contact Person:
Name: PAUL LAWRENCE
Address: 250 S 5 ST, BOISE ID
Contractor:
Name: BUSH DECOR & FIXTURE
Address: 3949 W YORKSHIRE DR, SOUTH JORDAN, UT
Contractor License No: BUSHDFI005LR
Permit Number:
Issue Date:
Permit Expires On:
Phone:
D04 -112
05/06/2004
11/02/2004
Phone: 208 429 -4034
Phone: 801 - 280 -0424
Expiration Date: 01/18/2006
SCRIPTION OF WORK:
DEMOLITION OF EXISTING STOREFRONT, NEW STOREFRONT, INTERIOR (NONBEARING) PARTITION, FLOORING,
CEILING AND LIGHTING.
Value of Construction: $ $60,000.00
Type of Fire Protection: SPRINKLERS /AFA
Type of Construction: VN
Fees Collected: $1,182.19
Uniform Building Code Edition: 1997
Occupancy per UBC: 0023
Pu
blic Works Activities:
Channelization / Striping: N
Curb Cut / Access / Sidewalk / CSS: N
Fire Loop Hydrant:
N
Number:. 0
Size (Inches): 0
Flood Control Zone:
N
Hauling:
N
Start Time:
End Time:
Land Altering:
N
Volumes: Cut 0 c.y.
Fill 0 c.y.
Landscape Irrigation:
N
Moving Oversize Load:
N
Start Time:
End Time:
Sanitary Side Sewer:
N
Sewer Main Extension:
N
Private:
Public:
Storm Drainage:
N
Street Use:
N
Profit: N
Non - Profit: N
Water Main Extension:
N
Private:
Public:
Water Meter:
N
** Continued Next Page **
doc: Devperm D04 -112 Printed: 05 -06 -2004
.. :..v lJ " "'r�' ,. ., ., , :tv •'� �'�K1 t�1 x� }y�:l�e+• `�.W .Jlcu:.:a,ti�untisa.AiLx' W.a.. s'..i"�.!..u:.�il.uw5.i.ilca �u.r�iauxa'+: W.w�Wtt.:w.xx "�
Z
Z
�
D
00
N
CO)
J �
CO) L
w
J
LL?
co
C%
= w
Z'
HO
Z f-
w
�5
U�
O N
off
w
�O
W Z
U=
O~
Z
City of Tukwila
19Q6
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
Permit Center Authorized Signature:- Date: S d y
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and
ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws
regulating constr on or th perfor ce ork. I am authorized to sign and obtain this development permit.
Signature: Date: eL � D
Print Name: - ,= /5 1
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is
suspended or abandoned for a period of 180 days from the last inspection.
doc: Devperm D04 -112 Printed: 05 -06 -2004
Z
w
a 2
JU
0
CO 0
w�
S2 LL
wO
LL
CO)
a
11-- O
Z 11-
w
UO
O CO
o H-
wW
L L
.• Z
w
U=
O H
Z
City of Tukwila
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
PERMIT CONDITIONS
Parcel No.: 2623049023
Address: 757 SOUTHCENTER MALL TUKW
Suite No:
Tenant: T- MOBILE
Permit Number:
Status:
Applied Date:
Issue Date:
D04 -112
ISSUED
04/01/2004
05/06/2004
1: ** *FIRE DEPARTMENT CONDITIONS * **
2: The attached set of plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following
concerns:
3: Maintain fire extinguisher coverage throughout.
4: Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5)
5: Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors
shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of
an approved type. (UFC 1207.3)
6: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle
is engaged from inside the tenant space. (UFC 1207.3)
7: Exit hardware and marking shall meet the requirements of the Uniform Fire Code. (UFC 1207 -1212)
8: Maintian sprinkler coverage per N.F.P.A. 13. Addition /relocation of walls, closets or partitions may require relocating
and /or adding sprinkler heads.
9: Sprinkler protection shall be extended to all areas where required, including all enclosed areas, below obstructions
and under overhangs greater than four feet wide. (NFPA 13- 4- 5.5.3.1)
10: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and
approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler
systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk
Insurers, Kemper or any other representative designated and /or recorgnized by the City of Tukwila, prior to submittal
to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance
#1901)
11: Contact the Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance
#1900 and #1901)
12: All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70)
13: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed
description of intended use.
14: Accumulation of combustible waste material is prohibited during the demolition phase of this project. Remove and
properly dispose of all waste material prior to the close of the working day and as often throughout the day as needed.
15: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of
doc: Conditions
D04 -112
Printed: 05 -06 -2004
.- fu�.._,.,_,.,_.4...�.._...� , w�......,.........._,.-_......, r�; AF„ �� ^�!!����,.,t�„`�t:- ���'��'..... r:', �... n. �# t85�1F�' n} �,•. x�+ � _:x!�'A�� rwfl!�nrruaaraaa*a€a�a+ sir.+ Deske�ra "2!s€M:1 k'tsR1(f4� 4� n7it�l
J
Z
~ w
L L.
JU
00
Cl)
C0 W
J =
H
C LL
WO
LLQ
CJ) D
=
�. w
H
Z'
H 0
Z
�5
U�
0�
off
wW
LL 0
w Z
UN
0
Z
..g City of Tukw
race
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
such condition or violation.
16: These plans were reviewed by Inspector 512. If you have any questions, please call Tukwila Fire Prevention Bureau at
Q
(206)575 -4407.
;F=- w
17: H.V.A.C. units rated at greater than 2,000 dm require auto - shutdown devices. These devices shall be separately zoned
v
in the alarm panel and local U.L. central station supervision is required. (City Ordinance #1900)
0 0
18: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be
co F
equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the
CO L
air - moving equipment upon detection of smoke in the main supply -air duct served by such equipment. Smoke detectors
w O
shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the
manufacturer's installation instructions. (UMC 608)
Q
co o
19: Duct smoke detectors shall be capable for being reset from the alarm panel. (City Ordinance #1900)
= CY
F - w
20: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #1900)
? F-
F- O
Z F-
21: Call the Tukwila Fire Department at 575 -4407 for approval of any system shut down. Have job site address, name and
LU Uj
Tukwila Fire Department Job Number available to confirm shut down approval. (City Ordinance #1900)
v o
ON
22: ** *BUILDING DEPARTMENT CONDITIONS * **
O H
w
23: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division.
F
�0
24: Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical
W Z
Co
work will be inspected by that agency (206- 835- 1111).
v
O
25: All mechanical work shall be under separate permit issued by the City of Tukwila.
Z
26: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any
construction. These documents are to be maintained and available until final inspection approval is granted.
27: Any new ceiling grid and light fixture installation is required to meet lateral bracing requirements for Seismic Zone 3.
28: Partition walls attached to ceiling grid must be laterally braced if over eight (8) feet in length.
29: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997
Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition).
30: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be
construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any
other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this
code shall be valid.
31: There shall be no occupancy of the building(s) until the final inspection has been completed by the Tukwila Building
Inspector.
32: Ventilation is required for all new rooms and spaces of new or existing buildings in conformance with the Uniform
Building Code and the Washington State Ventilation and Indoor Quality Code, Chapter 51 -13 WAC.
doc: Conditions D04 -112 Printed: 05 -06 -2004
a w '' .... T St ;�W { A ?F1 Fe a !' ak .M?wE'AraaS * nrxr+ rnrawatme v � �attc cMaa.�m. wr ?e� i f
f
I'
1
City of Tukwila
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws
regulating construction or the performanc work.
Signatu
Date: i�)S � d
Print Name:
S&
z
W
JU
UO
CO 0
J =
H
CO W.
WO
LL ?.
CO a.
H—
Z , �.
F- O'
Z f-:
W
25
U
O N
�H
W
H
W
— O!
.. Z
W
U =;
H
O ~'
Z
I Wiu,
1
f
CITY OF TUKWIL4
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
- Budding Niffiit
'
Mecliamcal'Perniit No.
Public V�orks Permit N
f
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
SITE LOCATION 1
CONTACT PERSON
'71l� King Co Assessor's Tax No.: I v
6. 230 �" Fa
"> 3 51� 3
Site Address: —CPM y i(`rl au Suite Number: 25 Floor: � S~t
� 1 2
Tenant Name: - r -. YY10 !P21Lt° New Tenant: .... Yes E] ..No
Property Owners Name: - Ne4f Lej d ��ltj Pflt� 2a�S2� hS
Mailing Address: J�p0) W (1-S ti6 - p) Tel v - t �.� LZn l b)5 Prn CAeS (_'�A . q O o ZS
City Stale Zip
1 Name: Rut.. _(Akk) Yl gyp_ Day Telephone: 40 - 4 L%- 40
Mailing Address: _ -2 5, S 5T T-�?Q (S-e- 830oZ
City State Zip
E -Mail Address: Fax Number: 1,6?2- -�74;3, - 4{0 �;%
I
y
GENERAL CONTRACTOR` .INFORMATION ,�. -t 1,
Company Name: TBD -5�
Mailing Address:
Contact Person:
E -Mail Address:
City State Zip
Day Telephone:
Fax Number:
.ARCHITECT OFRECORD - All plans must be wet stamped:by Architect of Record
Contractor Registration Number: Expiration Date:
"Aft'- orf [ yVy } i # *# 3 ' / ma y ` " t . �� ' ]]( { ' ] ( ] .#3i ] ��y fQft: iltit c i eeCtse musf se` f { ' re5enfed ' � ` jr : � ,(L7{i ' y ' , � 1 : : ' :e fi>r eriiiiti ssuanee'�:*
. •.• �•:.•� \•. ••••.ii: •: Ni•V•t ••. •1•• -•(•� ' T". At•• 11.• lJY: f••• V• t••.•••.••• it1••••••.•.••••:• Vl• t•.••.••••••..••. .tl` .............•!CT.'Yf1Y.:MM
Company Name: CS 4&y) wGlt!
j Mailing Address: 5. ��% $f ''Jd i -1 4 . 837 aL�
City State 'Lip
Contact Person: Day Telephone: Z01- 4 ZR.
I
E -Mail Address: Fax Number: 4<4 7 , , 8
ENGINEER OF RECORD = All plans must, be wet stamped by Engineer of Record.
Company Name: 65t+_� 7►f_4_ S. W t DN bv- G r
Mailing Address: ZrJO 5 . jf5 7r �d f� Ste! g�7 _70 Z
City State Zip
Contact Person: Day Telephone: - 4 Zq - 40 q
E -Mail Address: Fax Number: ZOl - 46
\applicalionApennil application (3 -2003)
312003 Pilge )
tF Ski' rit, UaK+ VKt7. 4: wi, w..:v�vrx..,.v..».....,.....n
«.:.,r.:=..0 .. vaw. �r..: uzww. n..-. A... xe.: , ::.r.,- «ia= .r:,«n.•�. �ci:tr�:c'.:,;.a.�: '„�.+eir;ai,i �rt;.,y'
t
Z
~ W
JD
UO
U
W=
S2 LL
W
J
U. Q
NCY CY
F W
Z
z�
W
W
D
Cf)_
0 H_
W
H C - )
W Z
iii
U=
O
Z
i i,` •,v
1
- Budding Niffiit
'
Mecliamcal'Perniit No.
Public V�orks Permit N
f
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
SITE LOCATION 1
CONTACT PERSON
'71l� King Co Assessor's Tax No.: I v
6. 230 �" Fa
"> 3 51� 3
Site Address: —CPM y i(`rl au Suite Number: 25 Floor: � S~t
� 1 2
Tenant Name: - r -. YY10 !P21Lt° New Tenant: .... Yes E] ..No
Property Owners Name: - Ne4f Lej d ��ltj Pflt� 2a�S2� hS
Mailing Address: J�p0) W (1-S ti6 - p) Tel v - t �.� LZn l b)5 Prn CAeS (_'�A . q O o ZS
City Stale Zip
1 Name: Rut.. _(Akk) Yl gyp_ Day Telephone: 40 - 4 L%- 40
Mailing Address: _ -2 5, S 5T T-�?Q (S-e- 830oZ
City State Zip
E -Mail Address: Fax Number: 1,6?2- -�74;3, - 4{0 �;%
I
y
GENERAL CONTRACTOR` .INFORMATION ,�. -t 1,
Company Name: TBD -5�
Mailing Address:
Contact Person:
E -Mail Address:
City State Zip
Day Telephone:
Fax Number:
.ARCHITECT OFRECORD - All plans must be wet stamped:by Architect of Record
Contractor Registration Number: Expiration Date:
"Aft'- orf [ yVy } i # *# 3 ' / ma y ` " t . �� ' ]]( { ' ] ( ] .#3i ] ��y fQft: iltit c i eeCtse musf se` f { ' re5enfed ' � ` jr : � ,(L7{i ' y ' , � 1 : : ' :e fi>r eriiiiti ssuanee'�:*
. •.• �•:.•� \•. ••••.ii: •: Ni•V•t ••. •1•• -•(•� ' T". At•• 11.• lJY: f••• V• t••.•••.••• it1••••••.•.••••:• Vl• t•.••.••••••..••. .tl` .............•!CT.'Yf1Y.:MM
Company Name: CS 4&y) wGlt!
j Mailing Address: 5. ��% $f ''Jd i -1 4 . 837 aL�
City State 'Lip
Contact Person: Day Telephone: Z01- 4 ZR.
I
E -Mail Address: Fax Number: 4<4 7 , , 8
ENGINEER OF RECORD = All plans must, be wet stamped by Engineer of Record.
Company Name: 65t+_� 7►f_4_ S. W t DN bv- G r
Mailing Address: ZrJO 5 . jf5 7r �d f� Ste! g�7 _70 Z
City State Zip
Contact Person: Day Telephone: - 4 Zq - 40 q
E -Mail Address: Fax Number: ZOl - 46
\applicalionApennil application (3 -2003)
312003 Pilge )
tF Ski' rit, UaK+ VKt7. 4: wi, w..:v�vrx..,.v..».....,.....n
«.:.,r.:=..0 .. vaw. �r..: uzww. n..-. A... xe.: , ::.r.,- «ia= .r:,«n.•�. �ci:tr�:c'.:,;.a.�: '„�.+eir;ai,i �rt;.,y'
t
Z
~ W
JD
UO
U
W=
S2 LL
W
J
U. Q
NCY CY
F W
Z
z�
W
W
D
Cf)_
0 H_
W
H C - )
W Z
iii
U=
O
Z
BUILDING PERMIT INFORN"�TION 206 431 3670
.. Valuation of Project (contractor's bid price): $ 60 000 . oc;�
Scope of Work (please provide detailed information): G} i?nry1.p t&lf ' ,
6
Will there be new rack storage? []..Yes M.. No
If "yes ", see Handout No. for requirements.
Provide All Building Areas.in Square Footage Below.
Addition to Type of Type of
Interior Existing Construction Occupancy per
Existing Remodel Structure New per UBC UBC
1a.. Floor
5 0 _ —0— — N h'1
2 .Floor.
T Floor.
:. :thru
.:;Basernetit
Accessory Structure*
Attached Garage .:.
Detached Garage
Attached Carport
Detached Carport
Covered Deck.
Uncovered Deck :.
PLANNING DIVISION:
Single - family building footprint (area f undation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, pro ide the following:
Lot Area (sq ft):= Floor area of principal dwelling: Floor area for accessory dwelling:
*Provide documen ation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Provided: Standard: Compact: Handicap:
Will there be� change in use? F� ....Yes F� ..No If "yes ", explain:
FIRE PROTECTION /HAZARDOUS MATERIALS:
' ... Sprinklers []..Automatic Fire Alarm n ..None E]. Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? n ..Yes n ..No
If "yes", attach list of materials and storage locations on a separate S -1/2 x 11 paper indicating quantities and Material Safety Data Sheets.
\applications%pumit application (3.2003)
3/2003 Page 2
Z
W
tY �
JU
UO
W�
CO LL
WO
LLQ
U �
=
�W
Z
HO
Z t^
W
W
UC3
ON
0 1.—
W
H -
tL O
.• Z
W
UZ
O
Z
Existing Building Valuation: $
MECHANICAL PERMIT INF01tMATION =206 -43:1 3670 : N : a -aJ U1fN
MECHANICAL CONTRACTOR INFORMATION
Company Name:_
Mailing Address:
Contact Person:
E -Mail Address:
City
Day Telephone:
Fax Number:
State Zip
Contractor Registration Number: Expiration Date:
* *An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance **
Valuation of Project (contractor's bid price): $
Scope of Work (please provide detailed information):
Use: Residential:
Commercial:
Fuel Type Electric
New ....
❑
New ...
❑
❑
Gas .. ❑
Replacement .... ❑
Replacement .... ❑
Other:
Indicate type of mechanical work being installed and the quantity below:
Unit .Type:
Qty
Unit Type:
Qty
Unit Type:
Qty
Boiler /Compressor:
Qty
Furnace <IOOK BTU
Air Handling Unit
>= 10,000 CFM
Other Mechanical
Equipment
0 -3 HP /100,000 BTU
Furnace>IOOK BTU
Evaporator Cooler
3 -15 HP /500,000 BTU
Floor Furnace
Ventilation Fan
15 -30 HP /1,000,000 BTU
Suspended /Wall/Floor
Mounted Heater
Ventilation System
30 -50 I-IP /1,750,000 BTU
Appliance Vent
Hood
50+ HP /1,750,000 BTU
Heat/Refrig/Cooling
System
Incinerator - Domestic
Air Handling Unit
<= 10,000 CFM
Incinerator — Comm /Ind
PERMIT APPLICATION NOTES - Appl>LCable to all perltnrts in th>ts`,applicahoin
0. .
l
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may extend the tilne for action by the applicant for a period not exceeding 180 days upon written request by the applicant as
defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDIN )t OR AUTHORIZED AGENT:
Signature: ` Date ? 7 x'64
Print Name: 2,y)d,\l v'lrnv Day Telephone: Z0S - 4 PSG' - 4L 3
Mailing Address: ?�L - 3 h' �r, P?� f)f 7370
City State Zip
Date Application Accepted: I Date Application Expires: Staff Initials:
\applications \permit application (3.2003)
3/2003 Page 4
���' `� rtsN`��N n*�m�arv.�warman om+. .r.r.».arN+«. ..r.+av��•vrKrnw., i ii'. �° S. Y'".= 2"- T�xt� .::S:rJt.::.:L'.:t:."`4 _.. -.. _ ...
Z
.� Z
W
qq
JU
UO
W=
H-
�LL
WO
9_J
WQ
N�
= a
�W
Z
H O
W ~
W
U
ON
OH
W
L
H�
—O
•
W Z
U=
H�
O
Z
City of Tukwila
6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
RECEIPT
Parcel No.:
2623049023
Permit Number
D04-112
Address:
757 SOUTHCENTER MALL TUKW
Status:
PENDING
Suite No:
Applied Date:
04/01/2004
Applicant:
T- MOBILE
Issue Date:
Receipt No.:
R04 -00391
Payment Amount:
463.94
Initials:
SKS
Payment Date
04/01/200411:28 AM
User ID:
1165
Balance:
$718.25
Payee: CSHQA
TRANSACTION LIST:
Type Method Description Amount
---- - - - - -- -- - - - - -- --------------------- - - - - -- ------ - - - - --
Payment Check 27681 463.94
ACCOUNT ITEM LIST:
Description Account Code Current Pmts
------------------------ - - - - -- ---------- - - - - -- ------ - - - - --
PLAN CHECK - NONRES 000/345.830 463.94
Total: 463.94
9487 04/02 071.0 TO 463-94
.. Rece Printed
fKx •i:H,17t�E.r�ki.4+'.h
Z
1-
JU
UO
N 0
CO)
J �
N L1..
WO
L L
CO)�
=d
�. W
Z�
H O.
Z F-
W
j.
O�
(3 H
W'
W .
LL
.. Z.
W
U=
O
Z
�,Y1tiV1, k�
1
f Cit y of Tukwila
f f9Q9
6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
RECEIPT
Parcel No.: 2623049023 Permit Number D04 -112
Address: 757 SOUTHCENTER MALL TUKW Status: APPROVED
Suite No: Applied Date: 04/01/2004
Applicant: T- MOBILE Issue Date:
Receipt No.:
R04 -00545
Payment Amount:
718.25
Initials:
SKS
Payment Date:
05/06/2004 01:12 PM
User ID:
1165
Balance:
$0.00
Payee: BUSH DECOR AND FIXTURE INC
TRANSACTION LIST:
Type Amount
- - - - -- Method Description - - - - --
Payment Check 715 718.25
ACCOUNT ITEM LIST:
Description Account Code Current Pmts
------------------------ - - - - -- ---------- - - - - -- ------ - - - - --
BUILDING - NONRES 000/322.100 713.75
STATE BUILDING SURCHARGE 000/386.904 4.50
Total: 718.25
Z
w
UO
U) 0.
J =
C0 L
w
U-Q
(0 =)
= CI:
�w
z =.
Z' �
Zo
W
w
�5
U�
O�
w
LL H
—0.
111 Z
U co):
O
Z
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PER
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (20a 431 -3670
Projg�;_.. `�
Type o
Address:
Date Called`
_.
Special Instructions:
Date Wanted: a.
m.
Requester:
J
Ph n�o:
b / /ir
I
Corrections required prior to approva9f-�
Z
= Z
WU
U
CO)
C0 W
J :c
�LL
W O
J
U. ?.
co)
Cl
= W
Z�
zO
W
W
U
O N
0 F-
W
U.
111 Z
CO)
O
Z
Approved per applicable codes.
INSPECTION RECORD ;�
Retain a copy with permit J 614 -1
INSPECTION NO. PE I O
CITY OF TUKWILA BUILDING DIVISION
.6300 Southcenter Blvd., #100, Tukwila, WA 98188 206)431-3670
Prpj.eet;
Type of Igsp ction:
Addr
�5? � sc ,���►1�
Date Called:
Special Instructions:
Date Wanted: a.m.
Requester:
... -a
Phone No:
-.Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
spe or: Da1 _ I el y OL
.00 REINSPECTION F E REQUIRED. rior to inspection, fee must be
id at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.: Date:
z
~ W
JU
UO
(1)0,
Cl) LU
�LL
W O
9 :
u_
cf)d
=w
I— O
z 1-
W
W
U�
O �'
i, f-
W UJ
F--
W Z
tll
U=
O~
z
INSPECTION RECORD
Retain a co with p ermit r �l
INSPEC ION NO. cop p PERMIT
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Project: • rr --
--- loll
Type of Ins
tion:
Addre g _ 1 -• ,/
Gv �
Called:
SpI .
C
A
Date Wanted:
�( .m.
/ 0� p.m.
Requester:
Phone No:
YOPIF/5
- 7119
` proved per applicable codes
Receipt No.: Date: I
,
Z
�Z
W
J U.
UO
W W
Co LL
WO
9a
N Z)
=
�W
z�
ZO
LU W
U
O C
0 H
WW
H L).
W Z
til
U=
O~
Z
Corrections required prior to approval.
INSPECTION RECORD �� �� , _�`
\3 _
Retain a copy with permit
INSPECTION NO. PER NO
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (20 )431 -3670
Projeci� --
j
Type of inspection:
1
, D Q
Ad S G �� �L�L
7S
Date Ca led:
-17 ' 04�
Special Instructions:
Date Wanted: a. m.
Requester:,
Phonon: !�
Approved per applicable codes. 92corrections required prior to approval.
COMMENTS:
Inspector Dater /
v
Fj $47.00 REINSPECT ON FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.: Date: :1
Z
JU
00
W=
J �-
�LL
WO
L L
CO
=
F W
Z�
F- O
z
W
�5
U
O co
O H
W LIJ
HF
111 Z
US
O ~;
Z
INSPECTION RECORD
Retain a copy with permit r ' l
INSPECTION NO. PERMIT NO
CITY OF TUKWILA BUILDING DIVISION LW
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Proje
_. '
Type of Inspection:
Address:
Date Called:
Special Instructions:
Date Wanted:
Requester:
U h
Phone No:
Inspector: Date:
$47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.: Date:
Z
H
'~ W
JU
0
ND
J =
CO
O _
WO
LLQ
= CY
�. W
Z'
H O
Z I—
U�
O N
�H
W LU
LL
�U
—O
.Z
W
U=
O
Z
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO.
j NQ CITY-OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (6)431 -3670
Project:
Type Pfrfs ection:
Addr ss:
Z sd M446
Date Called: /\
:5
S ecial Instructions �
Date Want�f: � � � 4'""
Requester:
1,. '
Phone o:
/
pproved per applicable codes. Corrections required prior to approV
COMMENTS:
I
Inspect r/'
$47. E)-REINSPEI
paid at 6300 Sou
Date-- -
Ue
:E REQUIRED. Prior to inspection, fee must e
Blvd., Suite 100. Call to schedule reinspection.
Receipt No.: Date:
Z
�Z
�W
2
JU
U0
CO
J H
S2 U_
W
J
LL
co
= W
1—
ZH
Z �.
UJ 5
UC1
fn
o —
W W
LL U
H
— Z
llJ
U =.
O I—
Z
O
1908
Thomas P. Keefe, Fire Chief
Steven M. Mullet, Mayor
Permit No. OC .
Retain current - inspection schedule
Needs shift inspection
Suite ##
Approved without correction notice
Approved with correction notice issued
Sprinklers:
Fire Alarm: 7
r
Hood & Duct: —�-
Halon : —
Monitor:
Pre -Fire:
Permits:
E
City of Tukwila
TUKWILA FIRE DEPARTMENT
FINAL APPROVAL FORM
Fire Department
Authorized Signature ~' `
FINALAPP.FRM
Rev. 2/19/98
Date
T.F.D. Form F.P. 85
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206 -575 -4404 • Fax. 206 -575 -4439
Z
~ w
JD
UO
N
J =
H
TLL
w
9-1
LL
C0 0
= a
�w
�O
Z�_
w
w
D
ON
o F-
wW
�- F-
U_ O
W Z
CO
b H.
O
Z
2001
2001 Washington State Nonresidential Energy
State Nonresidential Energy Code Compliance Form
2002-
Project Info
Project Address T- Mobile (Southcenter Mall)
Date 3/30/2004
Area in ft
Southcenter Mall Blvd.
For Building Department Use
RECEIVED
CITY OF T1 1KWI1 A
Tukwila, WA 98188
1.50
948.0
1422.0
APR 12004
Applicant Name: Bret Wilkinson, P.
1.50
PERMIT CENTER
Applicant Address: 250 South 5th Street - Boise, ID 83702
Applicant Phone: (toe) 393 -9635
Project Description ❑ New Building ❑ Addition [D Alteration El Plans Included
Indicate controls (Sections 1513) including commissioning requirements on plans.
0 Prescriptive p Lighting Power Allowance Q Systems Analysis
ompliance Option (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.)
Alteration Exceptions
(check appropriate box)
❑ No changes are being made to the lighting
❑ Less than 60°x6 of the fixtures are new, and installed lighting wattage is not being increased
Maximum Allowed Lighting Wattage (Interior) FILF l0,00V
Location
(floor /room no.)
Occupancy Description
Allowed
Watts per ft "
Area in ft
Allowed x Area
All
Retail sales
1.50
948.0
1422.0
Sales 101
Merchandise Display
1.50
608.0
912.0
101
Recessed Can Light (window display)
5
From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts
2334. 0
ivo[es:
1. Use manufacturer's listed maximum input wattage. For hard -wired ballasts only, the
default table in the NREC Technical Reference Manual may also be used
2. Include exit lights unless less than 5 wafts per fixture.
Proposed Lighting Wattage (Interibkyt all fixtures. For exempt lighting, not exception and leave Watts /Fixture blank.
Location
(floor /room no.)
Fixture Description
Number of
Fixtures
Watts/
Fixture
Watts
Proposed
102
2x4 Recessed Troffer w /Acrylic Lens
4
62.0
248.0
101
2X2 Recessed Troffer w /Specular Louvers
10
62.0
620.0
101
Recessed Can Light (window display)
5
101 G 102
Exit sign
2
101
Track Lighting (merchandise display)
25
50.0
1250.0
103, 104 i 105
4 -ft Surface Strip Light
1
62.0
62.0
I TT
.r,
GM
OF TUMI-14
.�
Y.: •
p
U
27517 O
`
S'Sr G
6iiY
N G DN
EXPIRES 01.08 -e)
Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts
2180.0
I
.. 7k /. X SRT" 1 i 4pY2f, 4, '. ?X.?'f FPYS.'+ r%, M' s: f C' Att,< YnzHrc! Y9, O. uat�'.'. mn:... A• l' ucr» .vrnncerta >.•� ; 'ert• ".4:' `;r11: ?!x; �`f ° 'v'9: } �34f9AhK`.[1�1`l .M«f,.�
Z
W
J
U
wz
F _
CQ W
WO
LL
U :)
= CY
W
ZH
HO
Z
W
W
UC3
O�
W
H
LL O
111 Z
U=
O
Z
' 2001 Washington State Nonresidential Energy Code Compliance Form
Maximum All Lighti "Wattage (Exterior)
Proposed Lighting Wattage (Exterior) the default table in the NREC Technical Reference Manual may also be used.
Location
Fixture Description
Allowed Watts
Area in ft
Allowed Watts
Location
Description
per ft or per If
(or If for perimeter)
x ft (or x if)
Covered Parking
(standard paint)
Not a part
0. W /ft
Covered Parking
(reflective paint)
Not a part
0.3 W/ft
Open Parking
Not a part
0.2 W /ft
Outdoor Areas
Not a part
0.2 W /ft
Bldg. (by facade)
Not a part
0.25 W /ft
Bldg. (by perim)
INot a part
7.5 W /If
Note; for building exterior, choose either the facade area or the perimeter method, but not both) Total Allowed Watts
Proposed Lighting Wattage (Exterior) the default table in the NREC Technical Reference Manual may also be used.
Location
Fixture Description
Number of
Fixtures
Watts/
Fixture
Watts
Proposed
Total Proposed Watts may not exceed Total Allowed Watts for Exterior Total Proposed Watts
. .:...,:.. :,..:.'...:s_ «.,.n.�:,..._:. ,.+. tii. vu:..,.,...,. 1;...>: way..:.: s...::u�.i.e +L.;;;aS..,tie:.vn.d r:`:a:sG4'.:��••+ =1, Jar .tn..4,e�.a�:.2.�:,+ .. :. s: t: i.�ea.':t:::.:wYl:ee!,wr:u.+id' �1ik l�«3tLUit.RiY`Ciro'�i+n : alt? 1 '„�15+ %:ai::Li!.;o0 *.1�7WiF.:1:
Q
~ W
' �Q
CO UJI
N o
J =
H
N W.
w O
�Q
Cl)
_ CY
�W
F- O
Z I--
Cl
O CO.
O H.
W W
Z
U
U
— O�
.. Z
w
O ~.
z
2001
2001 Washington State Nontesldentlai Energy Code
Prescrip Spaces
Qualification Checklist
Note: If occupancy type is "Other" and fixture
answer is checked, the number of fixtures in
the space is not limited by Code. Clearly
indicate these spaces on plans. If not
qualified, do LPA Calculations.
ashington State Nonresidential Energy Code Compliance Form
t.
,ompllance Forms Revised June 2002 -
Occupancy: O Warehouses, storage areas or aircraft storage hangers 0 Other
Lighting Fixtures: ❑ Check here if at least 95% of fixtures in the space meet all four criteria:
1. Fixtures are fluorescent, non - lensed, with only one or two lamps, and
2. Lamps are T -1, T -2, T -4, T -5, T -6, T -E 3. Lamps are 5 -50 Watts, and
4. Ballasts are electronic ballasts 5. Exit lights < 5 watts /fixture
6. Screw -in compact fluoresc fix do not qualify
TABLE 15 -1 Unit Lighting Power Allowance (LPA)
Use
LPA
Wls
Use
LPA
Is
Painting, welding, carpentry, machine shops
2.3
Police and fire stations
1.5
Barber shops beauty shops
2.0
Atria atriums
1.0
Hotel banquebconference /exhi bit! on hall '
2.0
Assembly spaces', auditoriums, gymnasia , heaters
1.0
Laboratories
2.0
Group R -1 common areas
1.0
Aircraft repair hangars
1.5
Process plants
1.0
Cafeterias, fast food establishments
1.5
Restaurantslbars
1.0
Factories workshops, handling areas
1.5
Locker and /or shower facilities
0.8
Gas stations, auto repair shops"
1.5
Warehouses", storage areas
0.5
Institutions
1.5
Aircraft storage hangars
0.4
Libraries
1.5
Retail ' retail banking
1.5
Nursing homes and hotel /motel guest rooms
1.5
Parking garages
See Section
1532
Wholesale stores (pallet rack shelving)
1.5
Mall concourses
1.4
Plans Submitted for Common Areas Only
Schools buildings (Group E occupancy only),
school classrooms, day care centers
1.35
Main floor building lobbies (except mall
concourses
1.2
Laundries
1.3
Common areas, corridors, toilet facilities and
washrooms, elevator lobbies
0.8
Office buildings, office /administrative areas in
facilities of other use types (including but not limited
to schools hospitals, pitals, institutions, museums, banks,
churches)
1.2
Footnotes for Table 15 - 1
1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not
mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based
upon the most comparable use specified in the table. See Section 1512 for exempt areas.
2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically
directed otherwise by subsequent footnotes.
3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet.
4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly.
5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet.
6) Includes pump area under canopy.
7) In cases in which a lighting plan is submitted for only a portion of a floor, a Unit Lighting Power Allowance of 1.35 may be used
for usable office floor area and 0.80 watts per square foot shall be used for the common areas, which may include elevator
space, lobby area and rest rooms. Common areas, as herein defined do not include mall concourses.
8) For the fire engine room, the Unit Lighting Power Allowance is 1.0 watts per square foot.
9) For indoor sport tournament courts with adjacent spectator seating, the Unit Lighting Power Allowance for the court area is 2.6
watts per square foot.
10) Display window illumination installed within 2 feet of the window, lighting for free- standing display where the lighting moves with
the display, and building showcase illumination where the lighting is enclosed within the showcase are exempt.
An additional 1.5 w /ft of merchandise display luminaires are exempt provided that they comply with all three of the following:
a) located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall).
b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with
two points of track attachment).
c) fitted with tungsten halogen, fluorescent, or high intensity discharge lamps.
This additional lighting power is allowed only if the lighting is actually installed.
11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be
defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face
area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by
racks.
Z
'~ W
JU
0
NQ
J
00 U_
WO
U Q
= d
W
Z` 3:
H O
Z I-
5
U�
ON
D f-
W
I=- H
�- O
Z
W
U=
O�
Z
`�:''vw1 u,i,4na l:'t viii �y;i�Ri;'F�•a ir�ae:+ltu �1(''t$:Kd:i:x'G.�...a i'y:3.'tia.:.; •M.
2001 Washington State Nonresidential Enerav Code Comaliance Form
i
Lighting Permit Plae Checklist LTG-CHK
2001 Washington State Nonresidential Energy Code Compliance Forms Revised June 2002 • KJM
Project Address T- Mobile (southcenter Mall)
Date 3/30/2004
The following information is necessary to check a lighting permit application for compliance with the lighting requirements in the
1994 Washington State Nonresidential Energy Code.
Applicability
(yes, no n.a.)
Code
Section
Component
Information Required
Location
on Plans
Building Department
Notes
LIGHTING. CONTROLS (Section 1513)
yes
1513.1
Local control /access
Schedule with type, indicate locations
E -2
yes
1513.2
Area controls
Maximum limit per switch
E -2
a.
1513.3
Daylight zone control Schedule with type and features, indicate locations
a.
vertical glazing
Indicate vertical glazing on plans
a •
overhead glazing
Indicate overhead glazing on plans
yes
1513.4
Display /exhib /special
Indicate separate controls
E -2
1513.5
Exterior shut -off
Schedule with type and features, indicate location
n.a.
(a) timer w /backup
Indicate location
x.a.
(b) photocell.
Indicate location
1513.6
Inter. auto shut -off
Indicate location
a.
1513.6.1
(a) occup. sensors
Schedule with type and locations
a.
1513.6.2
(b) auto. switches
Schedule with type and features (back -up, override capability);
Indicate size of zone on plans
_T_
4 1513.7
Commissioning
Indicate requirements for lighting controls commissioning
yes
Lighting Sum. Form
Completed and attached.
Schedule with fixture types,
lamps, ballasts, watts per fixture
E -1
r . a •
Elec motor efficiency
MECH -MOT or Equipment Schedule with hp, rpm, efficiency
If "no ". is. circled for any. question, provide. explanation:
Z
Z
�W
QQ�
JU
U
U
co W
W =
H
CO LL
WO }
J .
U. Q
c o
= a
F. W
Z
Z O.
W
W
U�
O�
0 t--
WW
�U
LL ~ O
.. Z
W
co
O�
Z
NYifi:adiL'FXAa:. NLY 4:
<�� re.., r: /.. :�h +3a: <: :K+iic��. .�5?:t �a��Fwi�.�t;lfi�^`;ti.' W;Rrx' ��J.��•. +aa::wu'.7wis wig ✓ '' u++id� '"+ -t'
2001 Washington State Nonresidential Energy Code Compliance
State Nonresidential Energy Code Compliance Forms
Lighting - General Requirements
1513 Lighting Controls. Lighting, including exempt lighting in
Section 1512, shall comply with this section. Where occupancy
sensors are cited, they shall have the features listed in Section
1513.6.1. Where automatic time switches are cited, they shall
have the features listed in Section 1513,6.2.
1513.1 Local Control and Accessibility: Each space,
enclosed by walls or ceiling- height partitions, shall be provided
with lighting controls located within that space. The lighting
controls, whether one or more, shall be capable of turning off
all lights within the space. The controls shall be readily
accessible, at the point of entry/exit, to personnel occupying or
using the space.
EXCEPTIONS: The following lighting controls may be
centralized in remote locations:
1. Lighting controls for spaces which must be used
as a whole.
2. Automatic controls.
3. Controls requiring trained operators.
4. Controls for safety hazards and security.
1513.2 Area Controls: The maximum lighting power that may
be controlled from a single switch or automatic control shall not
exceed that which is provided by a twenty ampere circuit
loaded to not more than eighty percent. A master control may
j be installed provided the individual switches retain their
capability to function independently. Circuit breakers may not
be used as the sole means of switching.
EXCEPTIONS:
1. Industrial or manufacturing process areas, as
may be required for production.
2. Areas less than five percent of footprint for
footprints over 100,000 square feet.
1513.3 Daylight Zone Control: All daylighted zones, as
defined in Chapter 2, both under overhead glazing and
adjacent to vertical glazing, shall be provided with individual
controls, or daylight -or occupant- sensing automatic controls,
which control the lights independent of general area lighting.
Contiguous daylight zones adjacent to vertical glazing are
allowed to be controlled by a single controlling device provided
that they do not include zones facing more than two adjacent
cardinal orientations (i.e. north, east, south, west). Daylight
zones under overhead glazing more than 15 feet from the
perimeter shall be controlled separately from daylight zones
adjacent to vertical glazing.
EXCEPTION:
Daylight spaces enclosed by walls or ceiling
height partitions and containing 2 or fewer light
fixtures are not required to have a separate switch for
general area lighting.
1513.4 Display, Exhibition, and Specialty Lighting
Controls: All display, exhibition, or specialty lighting shall be
controlled independently of general area lighting.
Revised June 2002 - KJM
1513.5 Automatic Shut -Off Controls, Exterior: Exterior
lighting not intended for 24 -hour continuous use shall be
automatically switched by timer, photocell, or a combination of
timer and photocell. Automatic time switches must also have
program back -up capabilities, which prevent the loss of
program and time settings for at least 10 hours, if power is
interrupted.
1513.6 Automatic Shut -Off Controls, Interior: Office
buildings greater than 5,000 sq. ft. and all school classrooms
shall be equipped with separate automatic controls to shut off
the lighting during unoccupied hours. Automatic controls may
be an occupancy sensor, time switch, or other device capable
of automatically shutting off lighting.
EXCEPTIONS:
1. Areas that must be continuously illuminated, or
illuminated in a manner requiring manual
operation of the lighting.
2. Emergency lighting systems,
3. Switching for industrial or manufacturing process
facilities as may be required for production,
1513.6.1 Occupancy Sensors: Occupancy sensors shall be
capable of automatically turning off all the lights in an area, no
more than 30 minutes after the area has been vacated.
1513.6.2 Automatic Time Switches: Automatic time switches
shall have a minimum 7 day clock and be capable of being set
for 7 different day types per week and incorporate an automatic
holiday "shut -off' feature, which turns off all loads for at least
24 hours and then resumes normally scheduled operations.
Automatic time switches shall also have program back -up
capabilities, which prevent the loss of program and time
settings for at least 10 hours, if power is interrupted.
Automatic time switches shall incorporate an over -ride
switching device which:
a) is readily accessible;
b) is located so that a person using the device can see the
lights or the areas controlled by the switch, or so that the
area being illuminated is annunciated; and
c) is manually operated;
d) allows the lighting to remain on for no more than two hours
when an over -ride is initiated; and
e) controls an area not exceeding 5,000 square feet or 5
percent of footprint for footprints over 100,000 square feet,
whichever is greater.
1513.7 Commissioning Requirements: For lighting controls
which include daylight or occupant sensing automatic controls,
automatic shut -off controls, occupancy sensors, or automatic
time switches, the lighting controls shall be tested to ensure
that control devices, components, equipment and systems are
calibrated, adjusted and operate in accordance with approved
plans and specifications. Sequences of operation shall be
functionally tested to ensure they operate in accordance with
approved plans and specifications. A complete report of test
procedures and results shall be prepared and filed with the
owner, Drawing notes shall require commissioning in
accordance with this paragraph.
Z
~ W
_3 L)
UO
W=
I—
�W
WO
LL
N
= ut
F
H O
W ~
W
UCl
O-
i0 H
W
H�
U. O
.. Z
W
U=
O
Z
PERMIT COORD COPY
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: D04 -112 DATE: 04 -01 -04
PROJECT NAME: T- MOBILE
SITE ADDRESS: 757 SOUTHCENTER MALL
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter #_ Revision # afteribefore permit is issued
DEPARTMENTS:
,per
Buil " Division
Public Works i , r L * 1
51 2- W c 4- - i�-Ocf
Fire Prevention
Structural ❑
oj(, P&
Planning Division
Permit Coordinator
DETERMINATION OF COMPLETENESS (Tues., Thurs.)
Complete Ed Incomplete ❑
Comments:
DUE DATE: 04 -06 -04
Not Applicable ❑
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TOES /THURS ROUTING:
Please Route 9
Structural Review Required ❑ No further Review Required ❑
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS
Approved ❑ Approved with Conditions [V
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
PERMIT COORD COPY
Documents /routing slip.doc
2 -28.02
l::::.A .4. z i,s i ��f a e' ; *, "•�.!'.S<s >.. *ri„e „ <.J:: �5++.,z v.�.1,a-wti1 >� :•'i. z .�:�.
DUE DATE: 05 -04 -04
Not Approved (attach comments) ❑
z
~ w
JU
UO
0
Ito W
J =
CO U _
w
9-1
U�
cod
= w
F-
Z~
F_ O
z I_
w
W
U� Ito
o�_
wW
HP
LL O
..Z
W
CO
O
Z
dEPARTMENT• - OF L ABOR AND INDUSTRIES• • .
State of
Washington
DEPARTMENT OF LABOR & INDUSTRIES
PO BOX 44450
OLYMPIA WA 98504 -4450
BUSH DECOR & FIXTURE INC
3949 W YORKSHIRE DR
SOUTH JORDAN UT 84095
FIRST CLASS MATE.
V$ POSTAGP,,
PAID
OLVMPTA WA
PERMIT NO 11 z
r-- Detach And Display Certificate -�
Detach And Display rertificee '
REGISTERED AS PROVIDED BY LAW ASI
CONST
;..:.. . DATE
CCOT " "'BUSHDF2005•UR 01/
EFFECTIVE D.�TE 06/19/.2000
BUSH DEC OR. ° &`' FTX,TURE. tNC '
3949 W YORKSHIRE DR
SOUTH J .095
Signetucc
Issu y EPARTIAENT O _ OR ANA INDUSTRIES J
F625.0524W W971
Please Remove
And Sign
Identification
Card Before
Placing In
Billfold
'.r
SUMMARY
AP I_ICAf3I E COL)[
1996 UNIT OPV CODE WITH WA`)HINGTON AMENDME_N TS
1 996 UNI{ 0PM 1 1 { C; IPIC CODE WI 1 H WASHINGTON AML IJDME N TS
1906 UNIT OPR A rAf CHAr ,IICAI COf)f WITH WASHING ION AML NDMENTS
19 96 UNIT ORM I'1 UMHINC CODE WITH WASHINGI ON AMENDMENTS
WASHINGT()N `)TAT[ f NI RGY CODE
OCCUPANCY GROUP M (MFRCANTILF)
TYPE 01 CONSTRUCTION V--N
FIR[ PROTECTION: (E) FULLY SPRINKLERED
ACTUAL TENANT AREA 945 S.F
AREA & OCCUPANT LOADING
SALES:
BACKROOM
INVENTORY /STOCKROOM
608.0 S.I. / 30
253.0 S.F. 100
84.0 S.F. 300
20.26 0CC.
2.53 OCC.
.28 OCC.
TOTAL OCCUPANCY
945 S.F.
23.07 OCC.
2 EMERGENCY EXITS PROVIDED
ACST
EAST
EXIT WIDTH REQUIRED (SALES AREA)
INFORMATION
SALES: 20.26 OCC.
x 0.2 IN. =
4.05 IN.
INVENTORY /OFFICE 2 53 OCC.
x 0.2 IN. =
.56 IN
TOTAL 60.90 OCC.
x 0.2 IN. =
4.61 IN.
TOTAL EXIT WIDTH PROVIDED 98 IN
(DOOR EX Q 8' -2" WIDE)
GENERAL CONDITIONS
1 ALL WORK AND MATERIALS SHALL BE INSTALLED IN ACCORDANCE WITH ALL CODES
HAVING JURISDICTION.
2 ALL WORK SHALL BE PERFORMED IN CONFORMANCE WITH THE BUILDING
MANAGEMENT'S RULES AND REGULATIONS.
3_ MODIFICATIONS TO THE BASE BUILDING STRUCTURE, CORE AREAS AND UTILITY
SYSTEMS ARF NOT IN THIS CONTRACT, EXCEPT AS NOTED ON THESE DRAWINGS OR
AS REQUIRED TO COMPLETE THE WORK INDICATED ON THESE DRAWINGS.
4 THE CONTRACTOR SHALL MAKE ALL ARRANGEMENTS AND PAY FOR ALL FEES,
CHARGES AND PERMITS REQUIRED AS WELL AS FOR HAULING, RIGGING AND
TRANSPORTATION CHARGES.
�• PENETRATIONS THROUGH FIRE -RATED ASSEMBLIES SHALL BE FIRE STOPPED PER
PER APPLICABLE CODE).
6. ALL. INSULATION MATERIALS, INCLUDING FACINGS, SUCH AS VAPOR BARRIERS OR
BREATHER PAPERS INSTALLED WITH FLOOR- CEILING ASSEMBLIES, ROOF- CEILING
ASSEMBLIES, WALLS, CRAWL SPACES, OR ATTICS SHALL HAVE A FLAME - SPREAD
RATING PER APPLICABLE CODES.
7. CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS. CONTRACTOR SHALL PROVIDE
MATERIAL AND INSTALL ALL SYSTEMS AS REQUIRED BY THESE DOCUMENTS AND
APPLICABLE CODES.
8. EXECUTION OF THE CONTRACT BY CONTRACTOR IS A REPRESENTATION THAT THE
CONTRACTOR HAS VISITED THE SITE AND HAS BECOME FAMILIAR WITH THE LOCAL
CONDITIONS UNDER WHICH THE WORK IS TO BE PERFORMED, THE CONTRACTOR
SHALL. VERIFY ALL EXISTING CONDITIONS BEFORE COMMENCING WORK AND SHALL
NOTIFY ARCHITFC ; HD /OR ENGINEER IF A CONDITION EXISTS WHICH PREVENTS THE
CONTRACTOR FROM ACCOMPLISHING THE INTENT OF THE DRAWINGS.
9. EXISTING FIRE SPRINKLER SYSTEM TO REMAIN. THE FIRE SPRINKLER
SUBCONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR SPRINKLER HEAD
RELOCATION /MODIFICATIONS TO THE AUTHORITY HAVING JURISDICTION FOR REVIEW
AND APPROVAL PRIOR TO BEGINNING WORK. FIRE SPRINKLER SUBCONTRACTOR TO
OBTAIN ALL REQUIRED PERMITS.
KEY PLAN
T LAf%M11 C
a
CSHQA
250 S. 5TH ST.
BOISE, ID. 83702
CONTACT: SANDY IRVINE
PH: (208) 429 - 4037
FAX: (208) 343 -4638
TENANT IMPROVEMENT
SOUTHC NT R MALL
1127 SOUTHCENT R MALL BLVD., SPACE 252
TUKWILA, WASHINGTON 98188
TENANT: T- MOBILE LANDLORD: WESTFIELD SHOPPINGTOWN
5242 SOUTH COLLEGE DRIVE 11601 WILSHIRE BLVD. SUITE 1200
SUITE 170 LOS ANGELES, CA 90025
SALT LAKE CITY, UT 84123 JOSE HERNANDEZ
CONTACT: MATT CHILD (310) 575 -5918
PH: (801) 860 -1178
ARCHITECT: CSHQA GENERAL TO BE DETERMINED
250 S. 5TH ST. CONTRACTOR:
BOISE, ID. 83702
CONTACT: SANDY IRVINE
PH: (208) 429 -4037
FAX: (208) 343 -4638
MECHANICAL,
ELECTRICAL &
PLUMBING
ENGINEER:
I
I FI LE COPY -- I
I understand that the Plan Check approvals are
subject to e rrors and omissions and approval of
plans does not authorize the violation of any
adopted code or ordinance. Receipt of con-
tractor's copy of approved plans acknowledged,
Dates
Permit No.
SEPARgT E M
REQUIRED FOR:
116 ECHgNICAL
ELECTRICAL
PLUMBIHO
NA 3AS PIPING
CITY OF 'ryUKMu
811ILDING DMgIIpN ,
�EVa�'
NO
_nom E
&. i dd. AM 0" -
SYMBOLS
Elevation Number A
ELEVATION
Sheet Where Drawn
DETAIL Elevation Number T
6
Sheet Where Drown
Elevation Number A
SECTIONS
Sheet Where Drown
ROOM NUMBER 0410
DOOR Door number - A
1
Hardware set 7
EQUIPMENT TYPV 0
RF VISION Ai\
FLOOR SURFACES nP T
FINISH TYPE P
ALIGN FINISH SURF ACES AL IGN
(lAS( SURF ACE
L
PI A' TI(" I AMIN A TE Ci5 2
ABBREVIATIONS
ABOVE FINISHED FLOOR
AFF
EACH
EA
INCH
IN
ACOUSTIC
ACST
EAST
E
INFORMATION
INFO
ADJUSTABLE
ADJ
ELECTRIC, ELECTRICAL
ELEC
INSIDE DIAMETER
ID
AIR CONDITIONING
A/C
ELEVATION
EL
INSULATED, INSULATION
INSUL
AIR HANDLING
AH
ELEVATOR
ELEV
INTERIOR
INT
AIR HANDLING UNIT
AHU
EMERGENCY POWER
EM
UNDERWRITER LABORATORY
UL
ALTERNATE
ALT
EMPTY CONDUIT
EC
JANITOR'S CLOSET
JC
ALTERNATE CURRENT
AC
ENGINEER
ENGR
JOINT
JT
ALUMINUM
AL
ELECTRIC WATER COOLER
EWC
JOIST
JST
AMPERES
AMP
ELECTRIC WATER HEATER
EWH
JUNCTION BOX
JB
ANCHOR BOLT
AB
EXHAUST
EXH
RADIUS
PAD. R
ARCHITECT
ARCH
EXISTING
EXIST.
LAMINATED
LAM
AT
0
EXPANSION
EXP
LAVATORY
LAV
AVERAGE
AV
EXPANSION JOINT
EXP JT
LEFT HAND
LH
RETURN AIR
RA
EXTERIOR
E X T
LENGTH
L
BEAM
BM
EQUAL
EQUAL
LIBRARY
LIB
BOARD
BD
LINEAR FEET
LF
FAHRENHEIT
F
LONG LEG HORIZONTAL
LLH
CABINET
CAB
FEET PER MINUTE
FPM
LONG LEG VERTICAL
LLV
CATALOG
CAT
FEET, FOOT
FT
CEILING
CLG
FINISH
FIN
MAINTENANCE
MAIN T
CENTERLINE
CL
FIRE EXTINGUISHER CAB_
FEC
MANUFACTURER
MFR
CERAMIC TILE
CT
FLOOR
FL
MASONRY
MAS
CLOSET
CLO
FLUORESCENT
FLUOR
MASONRY OPENING
MO
COLUMN
COL
FIRE RATED
FR
MAXIMUM
MAX
COMPANY
CO
STORAGE
STOP
MECHANICAL
MECH
CONCRE TE
CONC
GAUGE
GA
MEDIUM
MED
CONCRETE MASONRY UNITS
CMU
GALLON
GAL
MEZZANINE
MEZZ
CONFERENCE
CONE
GALLONS PER MINUTE
GPM
MINIMUM
MIN
CONTINUOUS
CONT
GALVANIZED
GAL V
MISCELLANEOUS
MISC
CONTROL JOINT
CJ
GENERAL CONTRACTOR
GC
MOUNTED
MTD
COORDINATE
COORD
GROUNDED FAULT !NTFRAUPT
GPI
MULLION
MUL
CORRIDOR
CORK
GYPSUM
GYP
ME_ T AL
M Tl
CUBIC FEET
CF
GYPSUM WAL BOARD
GWR
CUBIC FFE T PER MINUTE
CF M
NO T IN CONTRACT
NIC
HANDICAPPED
HE CF'
NOT TO SCAT F
NTS
DE RICA TED
DF -D
HARDWARE
HPW
NUMPF R
#. NO
DEPARTMENT
DEPT
HARDWOOD
HG WV
NOT APPLICAPLE
N/A
DEPTH
D
HEIGHT
HG 1, r4
DE TAIL
DE T
HE RTZ
HZ
DI AGON AL
DI AG
HOL LOW ME T Al
HM
OFF ICF
OFF
DIAME TFR
DIA
H0R110NTAt
HORIZ
ON CFNTFR
OC
PIMFNSION
DIM
H ORS[ P0WE R
HP
OPE NINC
OPNG
DISHWA R
DW
HOT WA TFR HF A TF R
HWH
O PPOSI TE
O p p
DOOR
DR
H;')(jp
HR
OUNCE
OZ
D0WN
DN
OVERALL_
C,A
DRAWING
DWG
OVERHF AD
OH
• •
BUILDING CITY OF TUKWILA
DEPARTMENT COMMUNITY DEVELOPMENT DEPARTMENT
PUBLIC WORKS DEPARTMENT, PERMIT CENTER
6300 SOUTHCENTER BLVD., SUITE 100
TUKWILA, WASHINGTON 98188
PAINTED
PTD
TELEPHONE
TEL
PANEL
PNL
THICK OR THICKNESS
THK
PARTITION
PTN
THRESHOLD
THRSLD
PERPENDICULAR
PERP
TILE
T
PERSONAL COMPUTER
PC
TONGUE & GROOVE
T &G
PHASE
PH
TOP
T
PLASTIC LAMINATE
P LAM
TYPICAL
TYP
PLATE
PL
SALES ELEVATIONS
PLUMBING
PLMB
UNDERWRITER LABORATORY
UL
PLYWOOD
PLYWD
POLYVINYL CHLORIDE
PVC
VERTICAL
VERT
PREFABRICATED
PREFAB
VESTIBULE
VEST
PREFINISHED
PREFIN
VINYL COMPOSITION TILE
VC T
PRELIMINARY
PRELIM
VOLTS
V
QUARRY TILE
QT
WALLBOARD
VV8
WELDED WIRE FABRIC
WWF
RADIUS
PAD. R
WIDTH
W
REFRIGERATOR
PEF
WINDOW
VD
REINFORCING
PEINF
WI TH
WV/W
REQUIRED
PLOD
WI THOU T
W /0
RESILIENT
RES
WOOD
WD
RETURN AIR
RA
RIGHT HAND
PH
YARD
YD
ROOM
RM
ROUGH OPENING
PO
SCHEDULE
SCHED
SECTION
SECT
SERVICE SINK
SS
SIMI( AR
Sim
SOUND TRANSMISSION
STV
SPECIFICATION
SPE C
SPECIFIED
SPECD
SQUARE
SQ
STANDARD
STD
STANDARD PIPE
Sr
STAINLESS STFFt
SS
STATION
STA
STEFL
STL
STORAGE
STOP
STRUC TURAI
STR",C T
SUSPENDED CE It INC,
SUSP
DRAWING INDEX
6RCHI
A -
-o
Cove S1 -iF_F_1
A
GENE' ^AL NOTES
A --
2
I~ Loon PLAN
A
- 2.1
SECTIONS DFIAILS
A. --
2.2
DEMOLI PLAN
A--3
REFLECTED CEILING PLAN
A -4
FIXTURE & FLOOR FINISH PLAN
A-5
DETAILS AND NOTES
A--6
SALES ELEVATIONS
A—
DETAILS
ENGINEERING
E---1 SYMBOLS, PANELS NOTES
E - 2 LIGHTING PLAN
E--3 POWER PLAN
E -4 TITLE 24
DEFERRED SUBMITTALS
FIRE SPRINKLER MODIFICATIONS
SIGN PERMIT
CIV OF JOKV10
APPROVED
APR 2 Z04�
p k " i tU
VICINITY MAP
T - MOBILE
1127 SOUTHCFN-ER MALL BLVD.
_ lV i - ' 1 AS $t �� i � i Ce e llr»
Ile-
` -- •-- - . .� �� _ . I � 1. � 0o a ir�a t
1 ` �Ip er Blvd iI Paik i
r ti
S 1CCth a' - _'
ftoft '
r' -,:; - - -----I 4 tT2n d DI MiOder Blvd N �'JV ? .31t , ,t
ran, st . `' , 9 180th 3t
-wio " .. s 1 t h St
I�
tot
i S 2 The
12
r
owl
.1
Z ISE
eG�l�
F€
5
JL
V �
N
N
0
�a
Q
a
Z
F � I
�T
PR DATE
04072.000 01/01/04
LAY S,
R£J'SE�
I
I
CITY OF TL4C*XA
APR - 1 2MK
m
5►+EE' ' ', E
OHM
A�o
i
s
14
A. GENERAL REQUIREMENTS
I. BASIC PROVISIONS
A THE STATEMENTS BELOW APPLY THROUGHOUT ALL OF THE CONTRACT DOCUMENTS TO ALL
CONTRACTORS, SUBCONTRACTORS SUPPLIERS, OWNER - BUILDERS AND OTHERS WHO MAY USE
THESE DRA WINGS DURING THE LIFE OF THIS PROJECT. THE TERM "CONTRACTOR" WHERE IT
APPEARS BELOW AND THROUGHOUT THE CONTRACT DOCUMENTS DESCRIBES ALL OF THESE
PARTIES.
B. IF WRITTEN SPECIFICATIONS ACCOMPANY THESE DRAWINGS ITEMS REQUIRED BY EITHER SHALL BE
CONSIDERED TO BE REQUIRED BY BOTH, CONFLICTS BETWEEN THE TWO SHALL BE GOVERNED BY
THE SPECIFICATIONS.
C. THE DRAWINGS AND SPECIFICATIONS MAY NOT CONTAIN ALL ITEMS THAT ARE NECESSARY FOR A
COMPLETE AND FUNCTIONAL PROJECT. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO
FURNISH AND INSTALL ANY ITEM WHICH MAY BE REASONABLY INFERRED AS BEING REQUIRED TO
ACCOMPLISH A FINISHED PRODUCT.
D. THE CONTRACTOR IS RESPONSIBLE FOR HAVING A REASONABLE KNOWLEDGE OF ALL CODES,
LAWS, STANDARDS, ACCEPTED METHODS AND PERFORMANCE CRITERIA APPLICABLE TO THE
PROJECT. ALL MATERIALS AND EQUIPMENT SHALL BE INSTALLED IN A WORKMANLIKE MANNER,
AND IN ACCORDANCE WITH STANDARD PROCEDURES RECOMMENDED BY THE MANUFACTURERS,
TRADE ASSOCIATIONS, OR OTHER GENERALLY RECOGNIZED CONSTRUCTION STANDARDS
ORGANIZATIONS. WORK SHALL CONFORM TO ALL APPLICABLE CODES, LAWS, STANDARDS, AND
REGULATIONS OF GOVERNING AUTHORITIES.
E. THESE DOCUMENTS HAVE NOT BEEN PREPARED UNDER A FULL SERVICES ARCHITECTURAL
AGREEMENT AND ARE NOT WARRANTED BEYOND A CUSTOMARY DILIGENCE. IF ANY OMISSION OR
DISCREPANCY 15 FOUND WITHIN OR BETWEEN THE CONTRACT DOCUMENTS, OR IF ANY FEATURE
SHOWN CONFLICTS WITH ANY LAW, CODE, STANDARD PRACTICE, PERFORMANCE CRITERIA, OR
ANY MANUFACTURER OR TRADESMAN WARRANTY, THE OWNER SHALL BE NOTIF PROMPTLY 50
THAT THE ITEM IN QUESTION CAN BE RESOLVED PRIOR TO CONSTRUCTION INVOLVING THE ITEM.
FAILURE TO NOTIFY THE OWNER OF A REASONABLY OBSERVABLE OMISSION, DEFECT,
DISCREPANCY, OR CONFLICT SHALL TRANSFER TO THE CONTRACTOR ALL RESPONSIBILITY FOR
ANY CONSEQUENCES OF SUCH FAILURE TO NOTIFY.
F. ALL ACTIONS TAKEN WITHOUT SPECIFIC DIRECTIVES STATED IN THE DOCUMENTS SHALL BE THE
RESPONSIBILITY OF TH05E TAKING SUCH ACTIONS.
G. T CONTRACTOR SHALL VISIT THE SITE TO BECOME FAMILIAR WITH EXISTING CONDITIONS BEFORE
CONSTRUCTION BEGINS. ALL REASONABLY OBSERVABLE CONDITIONS SHALL BE ACCOMMODATED
BY THE CONTRACTOR AFTER WORK HAS BEGUN.
H. SECURE ALL NECESSARY PERMITS AND LICENSES.
2. CLEANING
A. THE CONTRACTOR AND SUBCONTRACTOR SHALL AT ALL TIMES KEEP THE JOB FREE FROM EXCESSIVE
ACCUMULATION50F WAST MATERIALS AND RUBBISH.
3. WARRANTIES
A. THE CONTRACTOR SHALL WARRENT LABOR, MATERIALS, AND INSTALLED EQUIPMENT FOR A PERIOD
OF ONE YEAR FOLLOWING THE DATE OF OCCUPANCY BY THE OWNER OR THE DATE OF FINAL PAYMENT,
WHICHEVER OCCURS FIRST. THE CONTRACTOR SHALL REPAIR AT NO COST TO THE OWNER ANY FAILURE
OR DEFICIENCY DISCOVERED WITHIN THIS TIME PERIOD.
B_ COPIES OF WARRANTIES FOR SPECIFIC ITEMS SHALL BE DELIVERED TO THE OWNER PRIOR TO FINAL
PAYMENT.
4. ALL WORK SHALL CONFORM TO THE REQUIRMENTS OF ALL CODES AND REGULATIONS OF ALL
GOVERMENTAL AUTHORITIES HAVING JURISDICTION. SUCH CODES AND REGULATIONS SHALL HAVE
PRECEDENCE OVER THAT WHICH IS INDICATED ON THE CONSTRUCTION DOCUMENTS_ IN CASES OF
DISCREPANCIES, OMISSIONS, CHANGES IN THE CODES OR CODE INTERPRETATIONS BY THE CODE
OFFICIALS WHICH WILL CAUSE A CHANGE IN THE WORK NOTIFY INTERPLAN PRIOR TO PROCEEDING WITH
THAT PROTION OF THE WORKAFFECTED BY THE CHANGE.
B. THERMAL AND MOISTURE PROTECTION
1. SEALANTS
A. CAULKING: -- POLYURETHANE BASED OR "SILICONIZED" ACRYLIC ELASTOMERIC, PAINTABLE.
APPL AT LOCATIONS SHOWN AND WHEREVER NECESSARY TO FILL GAPS THAT COULD NOT
BE SEALED BY PAINTING ALONE.
B. SEALANT -- SILICONE BASE, CLEAR OR COLORED TO MATCH ADJACENT MATERIALS_ APPLY
SEALANT TO SHEET METAL, GLASS OR OTHER APPLICATIONS WHERE PAINTING 15 NEITHER
REQUIRED NOR DESIRABLE_ SEALANT COLOR SHALL MATCH OR BLEND WITH ADJACENT
MATERIAL COLOR.
C. DOORS AND WINDOWS
I. DOORS
A. INTERIOR SUITE DOORS -- 1 -3/4 ", SOLID CORE, HARDBOARD FACES(PAINT).
B. FRAMES -- KNOCK -DOWN STEEL, "TIMELY" OR EQUAL.
C. NEW OR REPLACEMENT DOORS TO EXIT CORRIDOR - MATCH BUILDING STANDARD.
2. HARDWARE
A. DOOR HARDWARE - SEE SHEET A -5
3. GLAZING
A. ALL GLASS SHALL BE INSTALLED WITH MANUFACTURER'S LABELS INTACT, NOT TO BE REMOVED
UNTIL FINAL CLEANUP. ALL INSULATING UNITS SHALL BE WARRANTED AGAINST EDGE SEAL FAILURE.
CONTRACTOR SHALL BE RESPONSIBLE FOR REPLACING BROKEN AND DAMAGED GLASS, AT NO
COST TO OWNER, UP TO FINAL ACCEPTANCE. UPON COMPLETION OF ALL CONSTRUCTION, LABELS
SHALL BE REMOVED AND GLASS SHALL BE WASHED CLEAN.
B. MATERIALS-
GL 1 - FROSTED GLASS
GL2 - TEMPERED C=LASS, GAUGE SPECIFIC TO DETAIL
D. MILLWORK NOTES:
I. ALL MILLWORK, STANDING AND RUNNING TRIM, CASEWORK AND PLASTIC LAMINATE WORK SHALL
CONFORM TO THE ARCHITECTURAL WOODWORK INSTITUTE (AWI) QUALITY STANDARD "CUSTOM
GRADE" UNLESS OTHERWISE NOTED.
2. ALL MILLWORK AND FINISH CARPENTRY FABRICATION SHALL BE FABR ICATED FROM FIELD
MEASUREMENTS WITH PROVISIONS FOR SCRIBING AS REQUIRED TO MEET FIELD CONDITIONS.
3. INSTALL ALL CASEWORK AND FINISH CARPENTRY PLUMB, LEVEL, TRUE AND STRAIGHT WITH NO
DISTORTIONS OR WARPS.
4_ ADJUST CABINETWORK AND HARDWARE 50 THAT DOORS AND DRAWERS OPERATE SMOOTHL
WITHOUT WARP OR BIND, LUBRICATE OPERATING HARDWARE AS RECOMMENDED BY HARDWARE
MANUFACTURER,
5. PROTECT INSTALLED CASEWORK AND PANELWORK IMMEDIATELY AFTER INSTALLATION AGAINST
SOILING AND DAMAGE. REMOVE PROTECTION JUST PRIOR TO TENANT ACCEPTANCE AND MOVE -IN
AND GLEAN ALL SURFACES.
b. ALL DOORS AND DRAWER FACES SHALL BE ADJUS AND ALIGNED PR IOR TO TENANT
ACCEPTANCE.
1, UNLESS OTHERWISE NOTED, CONCEALED HINGES SHALL BE USED THROUGHOUT.
8 BALL- BEARING GLIDES SHALL BE USED THROUGHOUT UNLESS OTHERWISE NOTED. BOX DRAWER
GLIDES SHALL HAVE A 15 RATING. FILES DRAWER GLIDES SHALL HAVE A 150 RATING.
S, PROVIDE AND INSTALL GROMM IN ALL MILLWORK AT SURFACES WITH WALL - M OUNTED
CONNECTIONS BELOW, FIELD COORDINATE SIZE OF GRO AND LOCATIONS WITH ARCHITECT.
10 VERIFY IN F IELD ALL DI PRIOR TO ORDERING PREFABRICATED CABINET WIDTH OF
CABINETS MAY BE INCREASED /DECREASED TO NEXT STANDARD SIZE AS REQUIRED. MILLWORK
NOTES:
II_ METER HOLLOW CHROME ROD WITH FLANGE ENDS BY STANLEY OR EQUAL,
12. SHELVING - (5) 34" x 12"D ADJUSTABLE SHELVES WITH HARDWOOD EDGE (PAINTED) ON KNAPP 4
vOGT 85/185 STANDARDS. BOTTOr► SHELF STARTS AT I' -3" AFFt REMAINING SHELvES SPACED 12"
CLEAR BETWEEN
r
E
I CsY P WALL
A. INTERIOR WALLBOARD (EXCEPT WET AREAS) -- 5i8" REGULAR GYPSUM BOARD.
B. WET AREAS (TOILET, COFFEE BAR) -- 5 /15" MOISTURE RES ISTANT GYPSUM BOARD.
C. FIRE SEPARATION WALLS -- 5/8" TYPE "x" G Y P S U M BOARD.
D. WALLS TO RECEIVE CERAMIC TILE -- TILE BACKER BOARD, 5/8" DENS- SHIELD (GP GYPSUM)
E. ALL GYPSUM BOARD SHALL BE FASTENED BY SCREWS. JOINTS SHALL BE CONCEALED WITH 3
STEP SYSTE INCLUDING EMBEDDING TAPE, MUDDING OVER TAPE, FINISH MUD AND SANDING.
FINISHED SURFACES SHALL BE SMOOTH, EVEN AND UNINTERRUPTED, WITHOUT ANY TAPE SHOWING,
FREE OF WAVINESS, JOINT LINES AND IMPERFECTIONS OF ANY SORTt READY FOR PAINT OR WALL
COVERINGS.
2. TILE
A. USE TILE COUNCIL OF AMER ICA INSTALLATION METHODS APPROPRIATE TO LOCATION. °vURFACEB
TO RECEIVE TILE SHALL BE EXAMINED BEFORE TILE 15 APPLIED AND CORRECTIONS MADE TO
UNSATISFACTORY CONDITIONS.
13. TOILET -- SHEET VINYL..
3_ CARPETING
A. PROVIDE ALL PAD, TACK STRIPS, ADHESIVES, TRANSITION STRIPS AND OTHER ACCESSORIES
REQUIRED FOR INSTALLATION. REVIEW SEAM PATTERN WITH OWNER PRIOR TO CUTTING OR
LAYING CRPET.
B. CARPET SUPPLIED THROUGH OWNER'S NATIONAL ACCOUNT AT MIDW OFFICE. CONTACT:
GORDON TODD OR CINDI CUNDIFF 801- 359 - 1681
4. PAINTING
A. ALL SURFACES SHALL BE CLEAN AND DRY BEFORE STARTING WORK. PROTECT ALL ADJACENT
SURFACES AND MATERIALS WITH COVERS, DROP CLOTHS OR MASKING, REMOVE HARDWARE,
FIXTURE PLATES, COVERS, ETC. BEFORE PAINTING: AND REPLACE AFTER PAINT HAS DRIED.
B. PREPARE GYP BOARD SURFACES BY DUSTING SURFACE AND REMOVING SPECKS OF COMPOUND.
SAND OR REPAIR ANY IMPERFECTIONS THAT WOULD SHOW THROUGH THE PAINT.
C. PREPARE METAL SURFACES BY CLEANING WITH DEGREASER. GRIND OR SAND MINOR
IMPERFECTIONS.
I. REGULAR GYPSUM BOARD - - WALLBOARD PRIMER PLUS ONE COAT (OR TO COVER) EGGSHELL
FINISH LATEX.
2. METAL -- FACTORY PRIMER PLUS TWO COATS SEMI GLOSS LATEX ENAMEL.
3. INTERIOR WOOD DOORS -- OIL BASE PRIMER PLUS TWO COATS SEMI GLOSS LATEX ENAMEL.
F. FINISH NOTES:
1. PROVIDE, STORE AND INSTALL ALL SPECIFIED FINISH MATERIALS IN
ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS.
2. NO SUBSTITUTIONS OF SPECIFIED FINISH MATERIALS WILL BE
ALLOWED WITHOUT PRIOR WRITTEN APPROVAL OF
INTERPLAN INCORPORATED.
3. ALL FINISH MATERIALS AND FINISH ASSEMBLIES SHALL CONFORM TO THE
REQUIREMENTS OF ALL CODES AND REGULATIONS OF ALL GOVERNMENTAL
AUTHORITIES HAVING JURISDICTION. ALL FINISHES MUST HAVE A FLAME SPREAD
RATING OF 200 OR LESS, AND A SMOKE GENERATION RATING OF 4 OR LESS AS
DETERMINED BY ASTM E 84.
4. ALL FINISH MATERIALS SHALL BE NEW, FIRST QUALITY
MATERIALS NORMALLY AVAILABLE FROM THE MANUFACTURER.
5. PREPARE ALL SURFACES SCHEDULED TO RECEIVE NEW FINISHES IN
ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS.
6. FLASH PATCH ALL AREAS WHERE FLOOR SURFACES ARE NOT SMOOTH,
LEVEL OR TRUE, PRIOR TO FINISH FLOOR INSTALLATION.
1. ALL FINISH FLOOR TRANSITIONS SHALL OCCUR AT THE CENTERLINE OF
DOORS OR CASED OPENINGS, UNLESS OTHERWISE NOTED.
S. ALL SEAMS AND JOINTS OF FINISH MATERIALS SHALL BE STRAIGHT,
SMOOTH AND CLEAN.
9. ALL SURFACES SCHEDULED TO RECEIVE PAINTED FINISHES SHALL RECEIVE
ONE (1) PRIMER COAT AND TWO (2) FINISH COATS, UNLESS OTHERWISE NOTED.
10. ALL WALLS, COLUMNS AND OTHER GYPSUM WALLBOARD SURFACES
SCHEDULED FOR PAINT FINISH SHALL BE FINISHED WITH LATEX FLAT ENAMEL,
UNLESS OTHERWISE NOTED. ALL PAINT GRADE DOOR CASINGS, PAINT GRADE
TRIMS, SHELVING, ETC. SCHEDULED FOR PAINT FINISH SHALL BE FINISHED WITH
LATEX SEMI -GLOSS ENAMEL, UNLESS OTHERWISE NOTED.
11. UNLESS NOTED OTHERWISE, ALL WALL /CEILING PAINT TO BE SMOOTH
ROLLED FINISH.
12. ONLY WHERE INDICATED "EQUAL TO" CR "SUBSTITUTIONS" FOR SPECIFIED
MATERIALS, OR FOR LONG LEAD TIME CONSIDERATION SHALL
SUBSTITUTIONS BE CONSIDERED BY INTERPLAN INCORPORATED.
13. BEFORE PROCEEDING WITH PROCUREMENT, THE RESPECTIVE INSTALLER
SHALL FIELD VERIFY DIMENSIONS TO ASSURE SUFFICIENT QUANTITIES OF
MATERIALS TO COMPLETE THE WORK.
14. ALL WALLS AND 5URFACE5 RECEIVING PAINT AND WALL COVERINGS, ETC.
SHALL BE PROPERLY PREPARED PRIOR TO FINISH INSTALLATION AS PER
MANUFACTURER'S SPECIFICATIONS. ALL J BEADS OR OTHER GYPSU
METAL TRIM SHALL BE SPACKLED AND BLENDED INTO ADJACENT SURFACE.
15. COMPLIANCE WITH THE MANUFACTURER'S REQUIREMENTS FOR HANDLING,
STORAGE, INSTALLATION AND PROTECTION 15 THE EXCLUSIVE RESPONSIBILITY
OF THE GENERAL CONTRACTOR AND HIS RESPECTIVE INSTALLERS ( I.E.,
FABRIC WALLCOVERING BACKING).
16. THE RESPECTIVE INSTALLER SHALL ADV15E ARCHITECT OF LOCATIONS
OF CHANGES IN DYE LOTS, BATCHES OR SIMILAR COLOR SHIFTS.
1 THE GENERAL CONTRACTOR SHALL PROVIDE ONE FINAL TOUCHUP OF
PAINTED SURFACES AFTER THE TENANT HAS MOVED INTO THE SPACE.
18. EXTERIORS OF STANDPIPE CABINETS AND FIRE EXTINGUISHER CABINETS
SHALL BE PAINTED IN SEMI TO MATCH ADJACENT WALL_
19_ ALL CEILING REGISTERS, VENTS, GRILLES, DIFFUSERS, SPEAKERS, ETC.
SHALL BE PAINTED IF REQUIRED TO MATCH CEILING.
20. FINISHES CALLED FOR SHALL EXTEND OVER, UNDER AND /OR BEHIND ANY ITEM
OF BUILT -IN MILLWORK, EQUIPMENT, MIRRORS, ETC. AS INDICATED ON THE DRAWINGS.
M
(I _ OWER AND _ _TELEPHONE NOTES:
I. SEE ELEV ATIONS FOR EXACT OUTLET LOCATIONS WHERE APPLICABLE.
2. PROVIDE AND INSTALL 2 - GANG BACK BOX WITH I -GANG TRir"M RING AND DRAG LINE TO CE ILING AT
TELEPHONE AND DATA LOCATIONS. PRO ✓IDE 3 '4' EMT TO CEILING AT INSULATED WALLS
UNLESS OTHERW NOTED.
3. REVIEW ALL ROUGHED IN BOXES IN FIELD WITH GENERAL CONTRACTOR PRIOR TO
INSTALLATION OF GYPSUM BOARD,
4. ALL TYPICAL RECEPTACLE MOUNTING HEIGHTS SHALL BE 18" AFF UNLESS OTHERWISE NOTED.
5. CONTRACTOR, TO RE VIEW DRA WINGS AND VERIFY INTENT WITH ARCHITECT, NOTIFY ARCHITECT OF
ANY DISCREPANCIES AND ERRORS OR OMISSIONS PRIOR TO PROCEEDING WITH FABRICATION OR
INSTALLATION.
6. REFER TO ELECTRICAL ENGINEER'S DRAWINGS FOR SWITCHING LISTS OF DEVICES AND
SPECIFICATIONS RELATING TO SPECIFIED EQUIPMENT.
1. REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS, SCHEDULES AND FIXTU TYPES.
8. GANG OUTLETS AND SWITCHES WHERE POSSIBLEt GANGED OUTLETS AND SWITCHES SHALL BE
INSTALLED WITH A COMMON FACEPLATE.
9. GENERAL CONTRACTOR TO VERIFY ALL CORE DRILLS PRIOR TO DRILLING.
10. COORDINATE ALL THERMOSTAT LOCATIONS WITH GENERAL CONTRACTOR PRIOR TO
INSTALLATION.
11. REFER TO ELEVATIONS AND SECTIONS TO COORDINATE M LOCATIONS AT ALL OUTLETS IN
MILLWORK. REVIEW WITH ARCHITECT FOR MOUNTING: INSTRUCTIONS AND PROPOSED GROMMET SIZES
AND LOCATIONS. CONTRACTOR SHALL PROVIDE AND INSTALL EXTENSION BOXES WHERE NEEDED.
12. RECEPTACLES ADJACENT TO "WET" AREAS SHALL BE GROUND FAULT INTERRUPTED (GFI TYPICAL).
13. CONTRACTOR SHALL COORDINATE MOUNTING HEIGHTS OF RECEPTACLES WITH
MANUFACTURER'S RECOMMENDATIONS FOR ALL EQUIP''IENT DESIGNATED.
14. PROVIDE AND INSTALL 3 /4" EMT IN ALL LOW PARTITIONS FROM DATA AND TELEPHONE LOCATIONS
TO CEILING. PROVIDE DRAG LINE IN EMT.
15_ OUTLETS SHALL BE STAGGERED RATHER THAN BACK -TO -BACK IN A SHARED PARTITION.
16. ELECTRICAL RECEPTACLES SHALL NOT BACK UP TO DATA LINE.
11. ALL CIRCUIT BREAKERS SHALL BE PROPERLY MARKED FOR THE OFFICES AND /OR FOR THE
AREAS THEY SERVICE. ALL PC OUTLETS SHOULD BE CONFIGURED ON A BASIS OF THREE (3)
OUTLETS PER 20 AMP CIRCUIT.
H. SPECIALTIES
1. MISCELLANEOUS SPECIALTIES
A. ACCESS DOORS - - MILCOR TYPE "DW" OR KARP "KDW ", WHERE REQUIRED FOR MAINTENANCE ACCESS IN
G YPSU M BOARD SURFACES,
B. TOILET ACCESSORIES (FOR NEW AND REMODELED TOILETS. MATCH FIXTURES IN EXIS TING RESTROOM,
RE: A-0.2-1 FOR SPECIFIED BRAND AND MODEL NUMBERS)
1. TOILET FLUSH CONTROLS SHALL BE OPERABLE W/ I HAND AND
SHALL NOT REQUIRE TIGHT GRASPING, PINCHING= OR TWISTING OF
THE WRIST. FLUSH HANDLE TO BE LOCATED TO OPEN SIDE OF TANK.
2. WALL HUNG SINK
3A. 1 -1/2 " X42 "o -OGRAB BAR
3B. 1 -1/2 5.5. GRAB BAR
4. I PAPER DISPENSER - WITH OUT STOPS
5. DISPENSER - DISPENSE FROM BTM.
Co. TOILET SEAT COVER DISPENSER
C_ FIRE EXTINGUISHER - 2A -IOBC ON WALL BRACKET_ CONFIRM REQUIREMENTS FOR TYPE, LOCATION AND
QUANTITY WITH LOCAL AUTHORITIES.
D. INVENTORY CAGE - OWNER FURNISHED CHAIN LINK ENCLOSURE AS MANUFACTURED BY KING WIRE PARTITIONS
INC. CONTACT: KING WIRE - FRED BESHID 323 256 4848
I. FURNIS
1. CABINETS AND STORE FIXTURES
A. ALL RETAIL STORE FIXTURES ARE TO BE 5UPPL'ED THROUGH OWNERS NATIONAL ACCOUNT AT HAMILTON FIXTURES INC.
2. CONTACT JOEL KATTERHAGEN 909 - 931 -3100 (WESTERN US) OR MARTY EVANS 909 - 931 -3136 (EASTERN US)
J. CONSTRUCTION NOTES
1, PROVIDE CEILING ACCESS PANELS AS REQUIRED BY MECHANICAL ENGINEERS, PAINT
OUT TO MATCH ADJACENT CEILING: COLOR. REFER TO MECHANICAL 4 ENGINEERING
DRAWINGS.
2. CONSTRUCTION DUMPSTER MUST BE PROVIDED BY TENANT. AT TENANTS SOLE
EXPENSE_ PLACEMENT BY LANDLORD PRIOR TO DELIVERY OF DUMPSTER. ALL
DAMAGE TO CENTER PREMISES WILL BE BILLED TO TENANT.
a� v"o
C\
1 2p�4
aP�2�w
r
0
y
s
l o ot
� Oh o
tarn
1 1F
O
a
O 3 o
3a o
a�
D
V�
N
on
a
�a
r
rMME4
C
R
!4
■
D ATE
04072.000 01/01/04
Ly
i REVISE
i �0lNlD
CITY Of TtiKWA
APR - 1 2004
PEFi11Aff COffM
A�l
v il
-,..-
A
FLOOR PLAN_ --
NORTH
(1) JOIST .,
TTACHE ('I TO
ABOVE
- AITACH h14
- 7/16" M 08 SCRFWS.
CEILING,
BAC DOOM
Ito
CEILING, MAIN
SALES
NEW 3 5/8'
FRAMED WALL.
25 GA. 0 24" O.C.
NEW 5/8" GYP. --C
BOARD BOTH
SIDES.
3/16 "x1 1
FASTENERS 0 12"
O.C.
TOP AND BOTTOM
CONTINUOUS TRACK.
FINISH FLOOR
32)PARTITION DETAIL
FL PLAN KEY NOT
EXIST. FULL HEIGHT DEMISING: WALL TO REMAIN.
NEW STOREFRONT AND GLAZING.
NEW 5 5/8" METAL STUD FURRING AT 16" O.G. TO 6" ABOVE MAIN SALES
CEILING WITH 5/8" GYPSUM BOARD.
NEW 8' - TALL CHAIN LINK INVENTORY ENCLOSURE AND GATE
FURNISHED BY TENANT, INSTALLED BY GC.
5 NEW MANAGER'S STATION, SEE DETAIL 2/A - 1, TENANT FURNISHED
CONTRACTOR INSTALLED.
NEW &' -0" LONG COUNTER W/ CABINETS BELOW, BY
CONTRACTOR.
EXIST. ELECTRICAL PANEL TO REMAIN SEE SHEET E -
NEW SHELVING BY G.C.
NEW 5 5/8" METAL STUD FRAMING AT 16" O.C. TO 6" ABOVE MAIN SALES
1 . CEILING WITH 5/8" GYPSUM BOARD ON EACH SIDE. SEE DETAIL 2 FOR
CONNECTION BRACING TO ROOF STRUCTURE.
im EXISTING DOOR, TO REMAIN.
II NEW CARPET TILE PATTERN. SUPPLIED BY TENANT INSTALLED BY
CONTRACTOR.
EXIST. RE5TROOM FIXTURES TO REMAIN.
14 COMPUTER STATION BY G.G. SEE SHEET A -4, FIXTURE SCHEDULE.
� 15 NEW DOOR, RE: DOOR AND HARDWARE SCHEDULE.
C1� Q
I6 TRAFFIC COUNTER FURN15HEO BY TENANT, INSTALLED BY GENERAL
2 1 ZQQ� CONTRACTOR.
APR �GU I'T NEW 2AIOBG FIRE EXTINGUISHER_
EXISTING WALL TO REMAIN,
19 CUSTOM MAGENTA 6ABLE50a "x42 "). SEE DETAIL 4 4 5 /A -2.I.
22� CUSTOM MAGENTA GABLE5(18 "x42 ") SEE DETAIL & d - /A -2_I
:4 ) FL OOR PLAN G NOTES
I ALL BACKROOM FURNITURES SHALL BE SUPPLIED AND INSTALLED
BY T- MOBILE
2 REMOVE ALL EXISTING FLOORING, PATCH 4 REPAIR 45 REQUIRED
TO PROVIDE SMOOTH LEVEL FLOOR SURFACE FROM HOLES, CRACKS
AND BUMPS TO ALLOW FOR NEW FLOOR FINISH,
3 PATCH AND REPAIR ALL EXISTING WALLS AS REQUIRED FOR NEW FINISH.
4, EXIT DOORS SHALL BE OPENABLE FROM THE EGRESS SIDE WIT"OUT
THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT.
ALL LOCKING / LATCHING HARDWARE SHALL RELE «SE WITH
ONE OPERATION SUCH 045 TURNING ONE DOOR LE' ✓ER OR PUSHING
ONE PUSH PLATE ( PER APPLICAPICAL CODE:. SEE EXCEPTION BELOW
FOR MAIN EXIT FROr - TENANT 5PACE5.
5. IN BUILDINGS IN OCCUPANC GROUPS B. F. M AND 5
OCCUPANCIES, TH+E MAIN EXTERIOR DOOR OR DOORS IS
PERMITTED TO BE EQUIPPED (1.1►TH KE'r OPERATED LOCKING
DEVICES FROM T"E EGRESS SIDE PROvIDED: THE LOCKING DEVICE
IS READILY DISTINGU'5 "ABLE A 5 LOCKED. THE MAIN EXIT CON51STS
OF A SINGLE DOCK O R PEA IR OF DOORS IF T)-SERE 1 5 A READIL'r
VISIBLE DURABLE SIGN CN OR ADJACENT TO THE DOOR ON T"E
EGRESS SIDE 5T,4TING DOOR TO REr"?AIN UNLOCKED WHEN
BUILDING 15 OCC *r"E SIGN SHALL BE IN LETTERS NOT LE55
THAN I" HIGH ON 4 CCNT4Z•49T'NG BACKGROUND. Wr -4ERE EGRESS
DOORS ARE USED 'N Ate► RS APPROVED 4U'rO"4TIC FLUSH
BOLTS SHALL BE PERT " ED TC BE USED PRCvIDED TWA' '64E
DOOR LEAF HAv�NG T•1E ""UrC"ATIC r-LUSN BCLT5 N45 NCT
NO DOORKNOB CPR 5„RF «CE "CUNTED WARDU04RE. r "E
UNLATCHING OF 4N- LEAF 5"4�.L NOT REQU'RE "CRE '"'N ONE
OPERATION. , `PER CODE'.
6 INTERIOR WALLS PER''TENT "r IONS ANN, 'E`^AOR•:►R`
PARTITIONS Ww'C -+ EXGEED h FEE"' 'N WE'G "' NC,-JD LNG '�E R r-'N S"
MATERIALS 3E DE5 'O 'RES 5"' -%L. LC «C5 'C �AJIW C�
'rwEY ARE SUBJEC'ED B.' NC' L. ESS `" N 4 -+CR ZCti'4` L ^4C
5 FOUNDS °ER 5Gj «RE FCC' PER C•+B,.E CC :E
�. CONTRACTOR 5N «�� aRE° «ARE :•'vC 1 DAIN - WALL PER
SPECIFICATIONS SEE 5
WALLS
CEILING FOR
APR - 1 2004
PEFW CEWER
FLOW
FLM
..
w • 0
`✓ERIFY CE'
BULKHE AD
,-L 14' -0"
" (E) MALL
SPLICE NEL
FRAMING W,
EXISTING
EXISTING '�--
MALL
NEUTRAL
STRIP
PATCH AND
REPAIR AS
NEEDED.
PAINT PER
MALL
REQUIRMENTS.
1
17
EXTERIOR ELEVATION
SCALE: 1 /4 " =1' -0"
EXTERIOR ELEVATION
VERIFY (E
BULKHEAD
14 ' -011
(E) MALL CEILING
23
25
R
to
1
N
R
I I wo : ,e "
12 i
8
1 2' -o%"
1
N
r
e I
BEYOND I
14
121-011 ilk
B.O. SUPPORT qV
FRAMING
I1' -0 "}-
3 ��
8
1 " ;
33/
Iq
BEYOND
EXTERIOR ELEVATION
SCAT F: 1 '4" 1' 0"
• •
•
GENERAL NOTES
A FIELD ✓ERIFY ALL EXISTING MAL` STRuCTuRES BULKHEAD : C N S *RUCT'ON LEASE
t-INE "DCA' (DESIGN CONTROL AREA. Lir"►ITS ETC COORDINA *E 1,04LL I
OPERATIONS MANAGER. PRIOR TO BEGINNING DV*10LITION OR l`*CNSTRUCTION.
P GLASS PANES DOORS PANELS ETC. SHALL BE TEMPERED t0 "SEE* LOCAL CODES
ALL EXPOSED EDGES OF GLASS SO44LL "A ✓E POLISHED EDGES
C. F!ELD ✓ERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION ANG A ✓.,JSr D'►"1ENSIONS
TO COORDINATE WITH INTENDED ALIGNMENT OR RELATIONSHIPS
KEYED NOTES
I.
ROLL DOWN GRILL BY ALUMATEK, INC. MOTOR OPERATED JNIT WITH E
I �
EGRESS DEVICE. DOORS SHALL REMAIN SECURED IN FULL OPEN POSITION WHILE
PREMISES 15 OPEN TO THE GENERAL PUBLIC AND SHALL NOT BE CLOSED IF THERE
ARE MORE THAN 10 OCCUPANTS WITHIN THE PROMI AND OPENABLE WITHOU THE
USE OF KEY OR SPECIAL KNOWLEDGE WHEN SPACE IS OCCUPIED.
2.
)�" CLEAR TEMPERED GLASS. BUTT GLAZED WITH OPEN EDGE JOINTS 3 /8 , MAX.
5
SPACING, WITH ANODIZED GLASS CLIPS.
3.
ALUMINUM STORE FRONT BY UNITED STATES ALUMINUM. CUT DOWN TOP AND BOTTOM
MULLIONS TO 2" HEAD s 6" BASE OVERALL HEIGHTS, RESPECTIVELY.
4.
BIRCH GABLE. RE: A2.1 -6 AND 1.
5.
MAGENTA GABLE. RE: A2.1 -4 AND 5.
6.
T- MOBILE SIGN AND ACCENT CHANNELS W/ 3/4" PUSH -THRU PLEXI, MIN. SIGN
5� go-RA
PACKAGE UNDER SEPARATE SUBMITTAL.
�.
L� XI 3M DUSTED CRYSTAL FILM 31725 -314 DIGITS , . AFFIX TO INTERIOR OF GLAZING.
PROVIDE AND INSTALL TO MEET LANDLORD REQUIRMENTS_
8.
%" GYPSUM WALL BOARD, PAINTED PI. RE: SHEET A - 5
S.
3/4" SOLID) BIRCH END CAP.
10.
SATIN ALUM, FINISH BASE BOARD.
11.
3/8" PLYWOOD, FIRE RESISTANT PER CODE AND LANDLORD REQUIREMENTS.
12.
3 5/8" METAL STUD BOX BEAM.
13-
5 % "THICK ALUM. LAY UP PANELS, MAGENTA.
14.
3% 16 GA. METAL FRAMING AT 24 O.G., UNLE55 NOTED OTHERWISE. NO WOOD FRAMING
ALLOWED. CONNECT AT EXISTING MALL STRUCTURE.
15.
ALUMN. "F" CHANNEL, SATIN FINISH.
16.
ALUMN_ "L" CHANNEL, POWDER COATED, MAGENTA.
11.
ALUMN. "J" CHANNEL, CLEAR ANODIZED.
18.
ALUMN. "U" CHANNEL, POWDER COATED, MAGENTA.
19.
OVERHEAD GRILL TRACK.
20.
DOWNL IGHT, SEE SHEET E-2
21.
4" ALUMN. CHANNEL, SATIN BRUSHED FINISH.
22.
ILLUMINATED T- MOBILE SIGN W/ 3/4" PLEXI. PUSH -THRU MIN.. COORDINATE WITH G.C./
>
04
ELECTRICIAN AND SIGN CONTRACTOR. SIGN SUBMITTAL UNDER SEPARATE SUBMITTAL.
23.
JUNCTION BOX FOR ILLUMINATED T- MOBILE SIGN,
24.
BLOCKING
25.
6" CLEAR ANODIZED CHANNEL.
26.
3/4" MAPLE VENEER MDF
21.
3g /8" Irc GA. CONTINUOUS METAL TRACK.
28.
ROLLDOWN GRILL SUPPORT BY ALUMATEK, INC. (11"xll" CABINET).
29.
ALUM. PANEL WITH BACKER SECURE TO METAL STUDS WITH CLIP ANGLES AT BOTTOM
AND METAL STUD. TYP.
30.
SUSPENDED ACOUSTICAL CEILING, SEE SHEET Al
31•
No" x 2V" HILTI HIT 150. LOCATIONS AS SHOWN.
NOT USED 32.
b
33.
0 10 "TEK" SCREWS, 6" O.C. UNLESS NOTED OTHERWISE.
NOT USED 3 4.
1 2 " TH I CK N A T „ , ALUM L UP r-, ,, NE T B
NOT USED 35. 3 5'' TA FR FR AMING.
36.3/4" X 3/4" ALUM. CHANNEL, PAINT FIN15H SATIN BLACK. BLIND FASTEN TO BACKUP
MATERAL (NO EXPOSED FASTENERS).
APPROO
AFINISH�
FLOOR
5 WR I CAL SEECTM -
MAGMA GABLE
8 -0
I�
0' -6"
I�
EXISTING WALL
1 CLEAR
SPACE FOR MELD
ADJUSTMENT
6 F+oRao►ff& WCTM -
sc� t� -t-or
I ' - -� 27
12' -0"
AL
FINISH
FLOOR
Al_
7 MINE%~ v�nc� sECTa� -
s�CV2W -Or'
Q
3
I �
I �
I �
5
... f h
o
5� go-RA
w
oi l
0
i
_
LA-
k�
vi
N
H on
W
0
>
04
z
R
A
� R
R
�
w �
i
O.IE
0072.0W
DATE
01/01/04
-lRAWN
LY
9
�Y1SE C
I
i
i
CITY Of TUKW A
APR - 1 2004
PEWT OOM
;►.� : r
SECTKM
AM WTAU
7 ���
F •
A�2
ApR 2 1 20Q�
r
Hoa¢aWM. %CTM -
sca.E: 1 yr -t-W
I •
) DEMOLITION - PLAN SCALE 1/4" 1'4r
C� �
21 2�ti�
p�
r h
I � �
a ow
•►� m
'd ex
gA�o�
LI
R M O °
�i
3 •IL
V •
N
on
N
d
CA
�a
a
•
f �}
I
I
a
PQCJECT DATE
aori.WO 01/01/04
�q�wN CHECKED
I REOSEC
WV
OKA
APR - 1 zoo4
PERwr
S nt;c
SNEf
A�2 I
F
2 KEYED NOTES
I REMO EX ISTING WALL AND ALL RELATED ITEMS PATCH REPAIR AND PAINT WALLS
AS REQUIRED WHERE DEMO WORK OCCURS.
? REMOVE ALL EXISTING INTERIOR AND FLOOR FIXTURES 'MILLWOORK. PATCH AND REP4• "R .45
NEEDED.
3. REMOVE ALL EX ISTING LIGHT FIXTU TILE CEILING a GRID AND GYP, BRC. CEILINGS
d. REMOVE EXIST. TILE. REPAIR FLOOR AS REQUIRED FCR NEW
FINISHES. REPAIR MALL TILE WHERE DEMO, WORK OCCURS.
5. EXISTING COLUMN TO REMAIN.
6. REMOVE AND INFILL EXISTING DOORWAY.
8 . REMOVE EXISTING STO REFRONT GLAZINCs.
9 . REMOVE EXISTING SHOW W INDOW PLATFORM.
IO . REMOVE EXISTING ROLL DOWN GRILL.
3 ) DEMOLITI NOTES
I. REMOVE ALL EXISTING INTERIOR PARTITIONS, DOORS AND DOOR FRAMES
SCHEDULED FOR DEMOLITION. REMOVE ALL MILLWORK, EQUIPMENT, ETC.
ATTACHED TO PARTITIONS OR COUNTERS SCHEDULED FOR DEMOLITION. VERIFY WITH
CONTRACTOR WHICH ITEMS ARE TO BE SAVED AND STORED FOR REUSE.
2. REMOVE EXISTING ACOUSTIC CEILING GRID AND TILES LIGHT FIXTURES,
AS SCHEDULED FOR DEMOLITION AND AS REQUIRED BY PARTITION
DEMOLITION AND NEW CONSTRUCTION WORK.
3. REMOVE EXISTING ELECTRICAL DEVICES, OUTLETS, TELEPHONE AND DATA
JACKS AND THERMOSTATS IN PARTITIONS SCHEDULED FOR DEMOLITION.
MODIFY EXISTING WIRING AS REQUIRED BY NEW CONSTRUCTION OR, IF NOT
REQUIRED, TERMINATE AND CAP OFF AT NEAREST PANEL OR SOURCE ABOVE
CEILING. VERIFY WITH LANDLORD WHICH ITEMS ARE TO BE SAVED AND
STORED FOR REUSE.
4. RELOCATE EXISTING HVAC DUCTWORK, CEILING DIFFUSERS AND RETURN
GRILLES AS SHOWN ON A -3.
5. REMOVE ALL CARPET.
Fo. REUSE EXISTING DOORS FRAMES, HARDWARE, LIGHT FIXTURES ELECTRICAL
DEVICES HVAC GRILLES, ETC. FROM DEMOLITION INVENTORY
OR SCHEDULED. CAREFUL REMOVAL, STORAGE AND
REINSTALLATION OF ALL MATERIALS AND EQUIPMENT 15 REQUIRED TO
PREVENT DAMAGE. REPAIR AND REFINISH ALL DAMAGED MATERIALS AND
EQUIPMENT AS REQUIRED FOR PROPER INSTALLATION. ALL MATERIALS AND
EQUIPMENT NOT REQUIRED FOR REUSE BY NEW CONSTRUCTION ARE TO BE
STORED FOR FUTURE USE.
1. REMOVE ALL CONSTRUCTION DEBRIS FROM AREA. REPAIR ALL ADJACENT
DAMAGED SURFACES, AS NECESSARY. PREPARE ALL DAMAGED SURFACES FOR
FIN15HES AS SCHEDULED OR REFINISH TO MATCH E XISTING FINISH. REPLACE
DAMAGED CEILING TILES*- REPAIR OR REPLACE DAMAGED CEILING GRID.
8. PROVIDE A SMOOTH, NEAT, CONTINUOUS APPEARANCE WHERE DEMOLITION
WORK MEETS ADJACENT EX15TING WORK. REMOVE EXISTING FINISHES AS
REQUIRED TO PROVIDE NEAT, STRAIGHT SEAMS AND TRANSITIONS BETWEEN
EXISTING AND MATCHING NEW FINISHES_
9. REPLACE OR RELOCATE, IN ACCORDANCE WITH LOCAL CODES, ALL FIRE
SUPPRESSION AND FIRE ALARM EQUIPMENT DISTURBED BY DEMOLITION WORK.
MAINTAIN INTEGRITY OF FIRE SUPPRESSION AND FIRE ALARM 5YSTEMS.
,...-
4
I
i
2 KEYED NOTES
I REMO EX ISTING WALL AND ALL RELATED ITEMS PATCH REPAIR AND PAINT WALLS
AS REQUIRED WHERE DEMO WORK OCCURS.
? REMOVE ALL EXISTING INTERIOR AND FLOOR FIXTURES 'MILLWOORK. PATCH AND REP4• "R .45
NEEDED.
3. REMOVE ALL EX ISTING LIGHT FIXTU TILE CEILING a GRID AND GYP, BRC. CEILINGS
d. REMOVE EXIST. TILE. REPAIR FLOOR AS REQUIRED FCR NEW
FINISHES. REPAIR MALL TILE WHERE DEMO, WORK OCCURS.
5. EXISTING COLUMN TO REMAIN.
6. REMOVE AND INFILL EXISTING DOORWAY.
8 . REMOVE EXISTING STO REFRONT GLAZINCs.
9 . REMOVE EXISTING SHOW W INDOW PLATFORM.
IO . REMOVE EXISTING ROLL DOWN GRILL.
3 ) DEMOLITI NOTES
I. REMOVE ALL EXISTING INTERIOR PARTITIONS, DOORS AND DOOR FRAMES
SCHEDULED FOR DEMOLITION. REMOVE ALL MILLWORK, EQUIPMENT, ETC.
ATTACHED TO PARTITIONS OR COUNTERS SCHEDULED FOR DEMOLITION. VERIFY WITH
CONTRACTOR WHICH ITEMS ARE TO BE SAVED AND STORED FOR REUSE.
2. REMOVE EXISTING ACOUSTIC CEILING GRID AND TILES LIGHT FIXTURES,
AS SCHEDULED FOR DEMOLITION AND AS REQUIRED BY PARTITION
DEMOLITION AND NEW CONSTRUCTION WORK.
3. REMOVE EXISTING ELECTRICAL DEVICES, OUTLETS, TELEPHONE AND DATA
JACKS AND THERMOSTATS IN PARTITIONS SCHEDULED FOR DEMOLITION.
MODIFY EXISTING WIRING AS REQUIRED BY NEW CONSTRUCTION OR, IF NOT
REQUIRED, TERMINATE AND CAP OFF AT NEAREST PANEL OR SOURCE ABOVE
CEILING. VERIFY WITH LANDLORD WHICH ITEMS ARE TO BE SAVED AND
STORED FOR REUSE.
4. RELOCATE EXISTING HVAC DUCTWORK, CEILING DIFFUSERS AND RETURN
GRILLES AS SHOWN ON A -3.
5. REMOVE ALL CARPET.
Fo. REUSE EXISTING DOORS FRAMES, HARDWARE, LIGHT FIXTURES ELECTRICAL
DEVICES HVAC GRILLES, ETC. FROM DEMOLITION INVENTORY
OR SCHEDULED. CAREFUL REMOVAL, STORAGE AND
REINSTALLATION OF ALL MATERIALS AND EQUIPMENT 15 REQUIRED TO
PREVENT DAMAGE. REPAIR AND REFINISH ALL DAMAGED MATERIALS AND
EQUIPMENT AS REQUIRED FOR PROPER INSTALLATION. ALL MATERIALS AND
EQUIPMENT NOT REQUIRED FOR REUSE BY NEW CONSTRUCTION ARE TO BE
STORED FOR FUTURE USE.
1. REMOVE ALL CONSTRUCTION DEBRIS FROM AREA. REPAIR ALL ADJACENT
DAMAGED SURFACES, AS NECESSARY. PREPARE ALL DAMAGED SURFACES FOR
FIN15HES AS SCHEDULED OR REFINISH TO MATCH E XISTING FINISH. REPLACE
DAMAGED CEILING TILES*- REPAIR OR REPLACE DAMAGED CEILING GRID.
8. PROVIDE A SMOOTH, NEAT, CONTINUOUS APPEARANCE WHERE DEMOLITION
WORK MEETS ADJACENT EX15TING WORK. REMOVE EXISTING FINISHES AS
REQUIRED TO PROVIDE NEAT, STRAIGHT SEAMS AND TRANSITIONS BETWEEN
EXISTING AND MATCHING NEW FINISHES_
9. REPLACE OR RELOCATE, IN ACCORDANCE WITH LOCAL CODES, ALL FIRE
SUPPRESSION AND FIRE ALARM EQUIPMENT DISTURBED BY DEMOLITION WORK.
MAINTAIN INTEGRITY OF FIRE SUPPRESSION AND FIRE ALARM 5YSTEMS.
,...-
4
I
• • 6
LIGHTING SCHEDULE
a 1I' -0" AFF.
CEILING MOUNT
TRACK L IGHTS
• IV-0" A .FF.
SPRINKLER HE
(TYP.)
GRILL, RE: DOOR
SCWEDULE
R PLAN E
h, 1C1 I 1-%I�M IGCC_s
6 II' -0" A.F.F.
I
1 '
r
NORTH
•
�J SHEET NOTES /CEILING MOUNTED DEVICES
I SEE S HT A -5 FOR ADDITIONAL NOTES AND LEGENDS.
2. SEE ENGINEERING D RAWINGS FO ExIT SIGN SPECIFICATION
3. PROVIDE BLACK POP -OFF SPRINKLERS ON CEILING
"CLOUDS" REMAINING PORTION OF CEILING SHALL
RECEIVE WHITE POP -OFF SPRINKLERS.
4. EXIT SIGNS ARE REQUIRED (PER APPLICABLE CODE.
5. EXITS AND EXIT PATHWAYS SHALL BE ILLUMINATED WITH A MINIMUM OF ONE
FOOT - CANDLE AT AT FLOOR LEVEL ANY TIME THE BUILDING 15
OCCUPIED. PROVIDE EMERGENCY ILLUMINATION OF EXIT
PATHWAYS. (PER APPLICABLE CODE).
43 CEILING GENERAL NOTES
1. VERTICAL HANGERS: SUSPENSION WIRES SHALL NOT BE SMALLER THAN NO. 12 GAGE SPACED AT 4' -0" ON CENTER OR NO. 10 GAGE AT 5' -0"
ON CENTER ALONG EACH MAIN RUNNER EACH VERTICAL WIRE SHALL BE ATTACHED TO THE CEILING SUSPENSION MEMBER AND TO THE SUPPORT
ABOVE WITH A MINIUM OF THREE TURNS. ANY CONNECTION DEVICE AT THE SUPPORTING CONSTRUCTION SHALL BE CAPABLE OF CARRYING NOT LESS
THAN 100 POUNDS.
2. SUSPENSION WIRES SHALL NOT HANG MORE THAN I IN (p OUT OF PLUMB UNLESS COUNTERSLOPING WIRES ARE PROVIDED.
WIRES SHALL NOT ATTACH TO OR BEND AROUND INTERFERING MATERIAL OR EQUIPMENT. A TRAPEZE OR EQUIVALENT DEVICE SHALL BE USED WHERE
OBSTRUCTIONS PRECLUDE DIRECT SUSPENSION. TRAPEZE WSPEN51ONS SHALL BE A MINIMUM OF BACK TO BACK I - 114" COLD - ROLLED
CHANNELS FOR SPANS EXCEEDING 48 ".
3. PERIMETER HANGERS: THE TERMINAL ENDS OF EACH CROSS RUNNER AND MAIN RUNNER SHALL BE SUPPORTED INDEPENDENTLY A MAXIMUM OF
8 INCHES FROM EACH WALL OR CEILING DISCONTINUITY WITH NO. 12 GAGE WIRE OR APPROVED WALL SUPPORT.
4. LATERAL FORCE BRACING, HORIZONTAL RESTRAINTS SHALL BE EFFECTED BY FOUR NO. 12 GAGE WIRES SECURED TO THE MAIN RUNNER WITHIN TWO
INCHES OF THE CROSS RUNNER INTERSECTION AND SPLAYED 90 DEGREES FROM EACH OTHER AT AN ANGLE NOT TO EXCEEDING 45 DEGREES FROM
THE PLANE OF THE CEILING. A STRUT FASTENED TO THE MAIN RUNNER SHALL BE EXTENDED TO THE STRUCTURAL MEMBERS SUPPORTING
THE ROOF OR FLOOR ABOVE. THE STRUT SHALL BE ADEQUATE TO RESIST THE VERTICAL COMPONENT INDUCED BY THE BRACING WIRES.
THESE HORIZONTAL RESTRAINT POINTS SHALL BE PLACED 12 FEET ON CENTER IN BOTH DIRECTIONS WITH THE FIRST POINT WITHIN 6' -0" FROM EACH
WALL. ATTACHMENT OF THE RESTRAINT WIRES TO THE STRUCTURE SHALL BE ADEQUATE FOR THE LOAD IMPOSED.
5. LATERAL FORCE BRACING MEMBERS SHALL BE SPACED A MINIMUM OF 6 INCHES FROM ALL HORIZONTAL PIPING OR DUCT WORK THAT 15 NOT
PROVIDED WITH BRACING RESTRAINTS FOR HORIZONTAL FORCES. BRACING WIRES SHALL BE ATTACHED TO THE GRID AND TO THE STRUCTURE IN SUCH
SUCH A MANNER THAT THEY CAN SUPPORT A DESIGN LOAD OF NOT LESS THAN 200 POUNDS OR THE ACTUAL DESIGN LOAD, WHICHEVER 15 GREATER,
WITH A SAFETY FACTOR OF 2. PERIMETER MEMBERS FOR TILE CEILING5 ENDS OF MAIN RUNNERS AND CROSS MEMBERS SHALL BE TIED TOGETHER TO
PREVENT THEIR 5PREADING. MAIN RUNNERS AND CROSS RUNNERS MAY BE ATTACHED TO THE PERIMETER MEMBER AT TWO ADJACENT WALLS WITH
CLEARANCE BETWEEN THE WALL AND THE RUNNERS MAINTAINED AT THE TWO OTHER WALLS.
LIGHTING FIXTURES:
ALL LIGHTING FIXTURES SHALL BE POSITIVELY ATTACHED TO THE SUSPENDED CEILING SYSTEM. THE ATTACHMENT DEVICE SHALL HAVE A CAPACITY OF
100 PERCENT OF THE LIGHTING FIXTURE WEIGHT ACTING IN ANY DIRECTION. NO. 12 GAGE HANGERS SHALL BE ATTACHED TO THE GRID MEMBERS
WITHIN 3 INCHES OF EACH CORNER OF EACH FIXTURE. TANDEM FIXTURES MAY UTILIZE COMMON WIRES.
LIGHTING FIXTURE WEIGHING LESS THAN 56 POUNDS SHALL HAVE, IN ADDITION TO THE REQUIREMENTS OUTLINED ABOVE, TWO NO, 12 GAGE HANGERS
CONNECTED FROM THE FIXTURE HOUSING TO THE STRUCTURE ABOVE. THESE WIRES MAY BE SLACK
LIGHTING FIXTURES WEIGHING 56 POUNDS OR MORE SHALL BE SUPPORTED DIRECTLY FROM THE STRUCTURE ABOVE BY APPROVED HANGERS.
PENDANT -HUNG LIGHTING FIXTURES SHALL BE 5UPPORTNG DIRECTLY FROM THE STRUCTURE ABOVE USING NO. 9 GAGE WIRE OR APPROVED
ALTERNATE SUPPORT WITHOUT U51NG THE CEILING SUSPENSION SYSTEM FOR DIRECT SUPPORT.
DO NOT ATTACH OR SHOOT PINS TO THE ROOF DECK. HANG FROM EXISTING JOIST OR BEAMS. SPAN STUD OR UNISTRUCT OR INTERMEDIATE
MEMBERS, WHERE NECESSARY.
SUSPENDED CEILING SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH APPLICABLE CODE.
RELOCATE EXISTING SPRINKLER HEADS AS NEEDED. RELOCATION OF FIRE SPRINKLER H E A DS SHALL
COMPLY WITH APPLICABLE CODE. AS REGULATED BY THE LOCAL FIRE DEPARTMENT
LOCAL FIRE CHIEF SHALL BE NOTIFIED WHEN o4NY REQUIRED FIRE ALARM SYSTEM IS PLACED
TEMPORARILY OUT OF SERVICE AND UPON RESTORATION OF SERVICE (PER APPLICABLE CODE).
REMOVE AND RE- INSTALL SPEAKERS, GRILLES SPRINKLERS ETC. THAT ARE AFFECTED BY NEW
CEILING WORK.
COORDINATE DEMO OF LIGHTS WITH ELECTRICAL PLANS.
�F ��oio
��� ApP ppvtp
� 2o a4
o 2
as TA)
o �
y��
I�
A
r
� y
LOW-
� o !
r A
i t s
� Q�o
E
ofi Q Q�o
sb =-
Z b
O
a
oi O
o
LLA
3i •
LL
U� •
vd
a --
N
'v►
IA
r4
ILI
r
Q
a
00
�• a
�
. J NW 4
V
r►
! I
PRGA c DATE
MC72.000 0
D RAWN
CH+FCKEC'
lr g
RfV+SEC
I
I
��
APR - 1 2004
��Tlk
PUN yNCt'
A � .. 3
r
Al
1
r 9 i
QTY. SYMBOLS
our-
- DESCRIPTION
LOCKER
WATER COOLER
U/G SAFE 24 ''W X 2 1 "H >t I( 11 G7
WE 1 20 LBS.
NO
1. ALL BACKROOM FIXUTURES t FURNISHINGS TO BE PROVIDED BY
T- MOBILE
(: o NOTE: RE: 41/A -5 FOR F INISH SCHEDULE
� 0.
CAS POD DETAIL
IAI
9>'-C" COUNTER - '
BY CONTRACTOR
�L
GET
MORE
MURAL
Tro I
WALL MTD.
ACCESSORY
PANEL
SALES
SUPPORT
-3 STATIONS
T 19�3 - '
T Iro
G
BRAND
MURAL
T14.1 J
BRAND
MURAL
T26 -
PRE
PAID
T15
POSTER
FRAME
WALL "TD.
ACCE SSOR'r
PANEL
TIS
EASEL
STAND
13' -10"
`- T4
WINDOW
DI
FIXTURE /FLOOR FINISH PLAN
_ 1
o °o
•o•
1,
T32.4
WALL MTD
DIVIDER FIXTURE
IP
Who
M oo I
(E) I
MANAGER'S rn
,.--•. DE r� R I I I I
T1
ACCESSORY
SPINNER
WALL
PANEL
T 10 ,
T20.31
POSTER
i FRAME X3
T15
i--
M
COVERAGE
PO TER
T21
j WALL
PANEL
1
TIO
L�
CONSUMER
CABINET-
3 STATIONS
T9.3
T1
----------
ACCESSORY ; POSTER
FRAME X3
SPINNER i'�'�
' T15
- T3.1 �'�
PRODUCT
I SL AND BRAND
MURAL •! Kr
i
TS
NORTH
PROSUMER
CABINET -
3 STATIONS
I T16
FIXTURE LIST
• T
FIXTURE QTY". DESCRIPTION GO I"'►►~1 EN 5
T1 3 CASH POD •
T1.1 2 GASH POD •
'
T3.1 I PRODUCT ISL AND 4 PHON STANDS 2 • 2 WIDE
COUNTER TRA
T3.2 C PRODUCT ISL AND 4 PHONE STANDS 2 • 2 WIDE
C TRAY
T3.3
0
PRODUCT I SL AND
12 PHON STANDS, 2 • 2 WIDE
TRAY
T4
I
WINDOW DISPLAY
.C,ah
•
T5
0
BRAND SIGN
Tb
2
WALL MO UNTED ACCESSORY PANEL
•
T1
2
ACCESSORY SPINNER
•
T8
I
BRAND MURAL
•
T8.1
C
BRAND MURAL
•
T9.1
0
CONSUMER CABINET - STATION
1 * 3 PKT. BROCHURE, 3 PH, STDS,
2 • 2 WIDE COUNTER TRAY
T9.2
O
CONSUMER CABINET -2 STATIONS
1 3 PKT. BROCHURE, 6 PH. STDS
3 • 2 WIDE COUNTER TRAY
T93
I
CONSUMER CABINET -3 STATIONS
2 • 3 PKT. BROCHURE, 9 PH. STDS,
4 • 2 WIDE COUNTER TRAY
TIC
2
WALL PANEL
2 SHELVES
RAM 5 PKT. BROCHURE
R
T11
C
DISPLAY CASE
•
T12
C
PHONE STANDS
«
T13
I
GET M ORE MURAL
T14.1
1
BRAND MURAL
•
T14.2
1
BRAND MURAL
•
T14.3
0
BRAND MURAL
•
T15
I
POSTER FRAME
T16
3
TRACK
91' -5 3/4" LIN. FT.
T11.3
0
DIVIDER FIXTURE
3 PANEL
T1
C
DIVIDER FIXTURE
4 PANEL
T11.5
0
DIVIDER FIXTURE
5 PANEL
T18
I
EASEL STAND
'
T19.1
0
SALES SUPPORT -1 STATION
T19.2
C
SALES SUPPORT -2 STATIONS
•
T19.3
I
SALES SUPPORT -3 5TATION5
«
T20.1
0
PRO5UMER COUNTER -1 STATION
3 PHONE STANDS, 2 6 2 WIDE
COUNTER TRAY
T20.2
0
PR:OSUMER COUNTER -2 STATIONS
6 PHONE STANDS, 2 • 2 WIDE
COJNTER TRAY
T20.3
I
PROSUMER COUNTER -3 STATION5
9 PHONE STANDS, 2 • 2 WIDE
C OUNTER TRAY
T21
I
COVERAG=E POSTER
«
T22
0
COUNTER TRAP
•
T23
0
BROCHURE HOLDER -3 POCKET
«
T24
0
BROCHURE HOLDER -5 POCKET
«
T25
0
GLASS DISPLAY CASE -WALL MTD.
TBD. - AS REQUIRED
T26
I
PRE PAID
•
T2
0
BACKROOM COUNTER, SEE I /A -1
BY G.C.
T28
I
MANAGER'S DESK, SEE 214-1
BY G.C.
T29
5
STOOL, TO LATER SPEC.
T32.4
I
WALL MTD DIVIDER FIXTURE
COMPUTER
I
BUSH VISIONS PERSONAL COMPUTER
STATION
STATION, CzALAXY FINISH- ORDER
B Y G.C.
1 WWW_5TAPLES.COM
THE ACCESSIBLE RESTROO" L,4vATORIE5 5HALL HA\/E ,4
MAXIMUM "EIGHT OF 34 INCHE5. WITH A MINIMUM KNEE
CLEr4R,4NCE OF 29 INCHES AND THAT THE DRAIN PIPING SHALL
BE INSULATED. PER APPL IGABLE CODE.
ALL PUBLIC: COUNTERS WITH A HEIGHT BETWEEN 28 AND 34
INCHES, AND BE A MINIMUM OF 36 INCHES LONG WITH KNEE
CLEARANCE OF 2'1 INCHES ON BOTH PUBLIC AND EMFLO�T EE
SIDES. NOTE: KNEE CLEARANCE 15 NOT REQUIRED FOR 51DE
APPROACH. (PER APPLICABLE CODE).
FOR ADDITIONAL INFORMATION. SEE ACCE55115ILIT�' DETAILS
ON .4 - 0.2.
4
� 2ad
1
G � i
z
z
m
a
a
a
w
7
te a' A
A
Ila
!! A
a
w
■
w �
PROJECT
0072:
DRAWN i
Lr
i REVSED
Olt i
gel
Il r-,8
F!
d�q
I la p
xm u u 0
I
o
Z•
�
o
1 3
oil le
O
LL
tI�
I
I
i
I
i
SATE
01/01/04
APR - 1 1004
i PEWT
c"ff• "
F1 am
Fem
A�4 PLMI
It
0 r 6
4 FNW gas=
5
DESCR
PAINT, BENJAMIN MOORE, CLOUD WHITE "OC -130
NWD.
TNRSLD.
REMARKS
MFG
FINISH/REMARKS
DIM.
PROS I ED 0LAS9
MFG. NUMBER
PORCELAIN TILE, OLYMPIA TILE- POLISHED FLAVIKER (LCB) 12" X 12" G T38
GRAPHITE ACK GROUT
°
MATCH EX,46-T,NG MALL TILE TO REAR FAGE
SCHL'4GE
OF MAGNETA GABLE.
O
CARPET, M LL K N CARPET- T UD , WINDOW PANE SUMMER DA
0 185 TENANT FURNISHED CONTRACTOR INSTALLED.
LATCHSET
ACCENT CARPET, P /2cJ03COLOR ACCENTS, COLOR "161, FOSSIL, 18 "X18" ON
COMFORT PLUS CUSHION BACK. TENANT FURNISHED CONTRACTOR INSTALLED.
COLLINS t AIKMAN, TRIAD MAT SERIES, STYLE: MAXIMUM FASHION, COLOR
0 00154 CHARCOAL
v
VINYL COMPOSITE TILE, ARMSTRONG- STANDARD EXCELON IMPERIAL
TEXTURE '"51889 COOL WHITE. CONTRACTOR FURNISHED AND INSTALLED.
Q
RUBBER COVE BASE, ARMSTRONG- GRAPHITE GRAY Mrol, 4" COVE
PROFILE UBBER COVE BASE, ARh'15TRONG- GRAPHITE GRAY 0 61, 4
COVE PROFILE. CONTRACTOR FURNISHED AND INSTALLED.
__eAtTIC
SILENCERS
5IRC14 PLYWOOD, CLEAR FINISH, BY FABRICATOR
IVES
2
1
A
METAL,
SCHLAGE
CLE;AR SATIN ANODIZED ALUMINUM, BY FABRICATOR
IFINIS1
RIVACYSET
SILVER F-VIZIDER C .,
FINISH
I
- .
HINCsES
ANODIZED MA5ENTA ALUMINUM TO MATCH CORPORATE STANDARD
McKINNEY
SATIN ALUMINUM
O
SILENCERS
-- D ACRY --L
IVES
, ,
1
SI GN
.
8'
C - O.
CLI
, � je
MTL
MFR.
5
3
NEW OVERHEAD
COILING DOOR
2
- .
3' - 0"
1' - 0"
1 3/4'
CEILING TILE, ARMSTRONG- DESIGNER SERIES 1 PARM 8334,
24 "X48" SQUARE LAY -IN, 15 1Iro" TEE.
HIN GES
CEILING TILE, ARMSTRONG- DESIGNER SERIES, *ARM 8388,
24 "X24" TEGULAR EDGE, 15116" TEE.
■r
- P0951151tIT155, TEXTURE 0 800 2 10 "COOL 041TE"
I
3
WIRE MESH
Z DOC)g - &gum=
DOOR
A L
FRAME
NWD.
TNRSLD.
REMARKS
MFG
FINISH/REMARKS
DIM.
MFG. NUMBER
1
°
AL SERIES
SCHL'4GE
SATIN ALUMIN
a
LATCHSET
PASSAGE LATCH
"D SERIES/RNODES OR EQUAL"
1 PR
HINGES
4.5 X 4.5
TA2114 U5 26D
Q
SATIN ALUMINUM
MAT./
SILENCERS
0 20
IVES
2
1
A
I LOCATION
SCHLAGE
SATIN ALUMINUM
IFINIS1
RIVACYSET
PRIVACY LOCK
FINISH
I
11/2
HINCsES
4.5 X 4.5
TA2114 US 26D
McKINNEY
SATIN ALUMINUM
O
SILENCERS
0 20
IVES
1
SI GN
ENTRY
8'
C - O.
_
ALUM.
MTL
MFR.
5
3
NEW OVERHEAD
COILING DOOR
2
INTERIOR
3' - 0"
1' - 0"
1 3/4'
PAINT WD
HIN GES
HM.
PAINT
I
I
3
WIRE MESH
BLDG. STD.
4
OWNER
EXIT DEVICE
ARM -A -DOOR
OWNER SUPPLIED,
CYLINDER LEVER
HINGED
3' -0"
6' -10"
FURNISHED
PANIC DEVICE'
888 - 168 - 1301
3
LOCK TENANT
DOOR BY
TW I L A GORE
801- 284 -1015 TO ORDER.
FURNISHED,
KING WIRE
ALL HARDWARE BY
DOOR". MANUF-ACTURE.
CONTRACTOR
PARTITIONS
PROVIDE EMERGENCY
ACCESS RELEASE
ALL DOOR HARDWARE TO BE COMMERCIAL GRADE SATIN
INSTALLED
4
EXISTING TO
REMAIN
EXIST
E XI ST
EXIST
EXIST
PAINTED SEMI-GLOSS UNLESS OTHERWISE SPECIFIED.
MTL
EXIST
4
AND SLIDING) SHALL NAVE A SMOOTH UNINTERRUPTED
5URFACE OR SHALL BE PROVIDED WITH 10 - INCH 1 SMOOTH
NOTE: ALL HARDWARE SHALL
3 LE 3
HARD WARE sc COMPL ANT.
_.,.,,......._
SET
QTY.
ITEI'`''I
DESCRIPTION
MFG
FINISH/REMARKS
MFG. NUMBER
1
LEVER
AL SERIES
SCHL'4GE
SATIN ALUMIN
LATCHSET
PASSAGE LATCH
"D SERIES/RNODES OR EQUAL"
1 PR
HINGES
4.5 X 4.5
TA2114 U5 26D
McKINNEY
SATIN ALUMINUM
3
SILENCERS
0 20
IVES
2
1
LEVER
AL SERIES
SCHLAGE
SATIN ALUMINUM
RIVACYSET
PRIVACY LOCK
"D- SERIES/RHODES OR EQUAL"
11/2
HINCsES
4.5 X 4.5
TA2114 US 26D
McKINNEY
SATIN ALUMINUM
O
SILENCERS
0 20
IVES
1
SI GN
RESTROOM
MEET ALL LOCAL
AGCESSABL IT1' GODE5
3
1
LEVER LATCH
-
GALVANIZED STEEL
1 1/2" PR
HIN GES
-
GALVANIZED STEEL
I
DOORSTOP
BLDG. STD.
4
1
EXIT DEVICE
ARM -A -DOOR
OWNER SUPPLIED,
EXIT ONLY
SERVICES
CONTRACTOR
PANIC DEVICE'
888 - 168 - 1301
INSTALLED. CONTACT:
TW I L A GORE
801- 284 -1015 TO ORDER.
ALL HARDWARE BY
DOOR". MANUF-ACTURE.
PROVIDE EMERGENCY
ACCESS RELEASE
ALL DOOR HARDWARE TO BE COMMERCIAL GRADE SATIN
STAINLESS STEEL, SATIN NICKEL OR SATIN ALUMINUM.
• EXIT HARDWARE SHALL BE COMPLIANT WITH APPLICABLE
CODE.
• ALL DOOR PULLS AND LOC:<5ET5 TO BE COMMERCIAL
GRADE SATIN STAINLESS STEEL FINISH BY SCHLAGE,
D SERIES /RH0DE5 OR EQUAL.
• ALL DOORS, JAMBS, I CEILINGS TO BE PAINT GRADE
PAINTED SEMI-GLOSS UNLESS OTHERWISE SPECIFIED.
v ALL INTERIOR 1- 4ARDWARE 15 TO BE LEVER TYPE OR APPROVED
EQUAL FOR DISABLED ACCESS. TH15 INCLUDE5 DOORS AND 51NK5.
THE BOTTOM 10" INCHES OF ALL DOORS (EXCEPT .AUTOMATIC
AND SLIDING) SHALL NAVE A SMOOTH UNINTERRUPTED
5URFACE OR SHALL BE PROVIDED WITH 10 - INCH 1 SMOOTH
METAL PANEL AT THE BOTTOM TO ALLOW THE DOOR TO BE
OPENED BY A WHEELCHAIR FOOTREST WITHOUT CREATING A
TRAP OR HAZARDOUS CONDITION. (PER APPLICABLE CODE).
0
W �
sill
h
Q i
_E
444 pry,
a
r-
04 Mal �alo
w rn moo
e� dai Ms
u
Q
3 �
v�.
C4
on
r4
V
a» IL+
rA
F
m C4
s
■
■
m ~
ORCOECT DATE
04m.m 01/01/04
DRAWN C►+ECNfD
Lr 9
R"SEC
I op u
APR - 1 2004
CIETAU AM
s►� t
A -5
A
THE MAXIMUM FLAME SPREAD CL-ASS OF FINISH MATERIALS USED ON INTERIOR
WALLS AND CEILINGS SHALL NOT EXCEED THAT SET FORTH i r -, . , i . ! I IT
i_uiit TESTING SHALL BE MADE BY AN APPROVED TESTING AGENCY TO ESTABLISH
SURFACE -- BURNING CHARACTERISTICS AND TO SHOW THAT MATERIALS WHEN
CEMENTED OR OTHERWISE FASTENED IN PLACE WILL NOT READILY BECOME
DETACHED WHEN SUBJECTED TO ROOM TEMPERATURES OF 300 DEGREES FOR 25
MIN. CLASSES OF MATERIALS BASED ON THEIR FLAME SPREAD INDEX SHALL BE AS
SET FORTH
��02.2 CLASSIFICATION: THE CLASSES OF MATERIALS BASED ON THEIR FLAME
SPREAD INDEX SHALL BE AS SET FORTH IN TABLE 8 —A. THE SMOKE DENSITY SHALL
BE NO GREATER THAN 450 WHEN TESTED IN ACCORDANCE WITH UBC STANDARD 8 -1
IN THE WAY INTENDED FOR USE.
of to o
ONog*lo
�'
N ??, I 1 2QQ
q.&�
'N i W: v 411 J: mxe� W.T:Tz
:03
•
A
THE MAXIMUM FLAME SPREAD CL-ASS OF FINISH MATERIALS USED ON INTERIOR
WALLS AND CEILINGS SHALL NOT EXCEED THAT SET FORTH i r -, . , i . ! I IT
i_uiit TESTING SHALL BE MADE BY AN APPROVED TESTING AGENCY TO ESTABLISH
SURFACE -- BURNING CHARACTERISTICS AND TO SHOW THAT MATERIALS WHEN
CEMENTED OR OTHERWISE FASTENED IN PLACE WILL NOT READILY BECOME
DETACHED WHEN SUBJECTED TO ROOM TEMPERATURES OF 300 DEGREES FOR 25
MIN. CLASSES OF MATERIALS BASED ON THEIR FLAME SPREAD INDEX SHALL BE AS
SET FORTH
��02.2 CLASSIFICATION: THE CLASSES OF MATERIALS BASED ON THEIR FLAME
SPREAD INDEX SHALL BE AS SET FORTH IN TABLE 8 —A. THE SMOKE DENSITY SHALL
BE NO GREATER THAN 450 WHEN TESTED IN ACCORDANCE WITH UBC STANDARD 8 -1
IN THE WAY INTENDED FOR USE.
of to o
ONog*lo
�'
N ??, I 1 2QQ
q.&�
EASEL
STAND
INTERI ELEV
SCALE: 1/2" = V -0"
DER
IRE
INTERIOR ELEVATION
SCALE: 1/2" = V -0"
BRAKE ARM POSITION ON
MOUNTINCs MWACrcFZT M;:r_niat=
SETTING ON TR4
� NOTE:
D O,NOT L IFT ARM ALL
THE WAS ' _UP
C LEVELER LOCK DETAIL
l SCALE N
0 • 6
4
INTERIOR ELEVATION
SCALE: 1/2" = V -0"
INTE ELE
SCALE: 1/2" = 1' -0"
NOTE_: A L IBRAKE A '►5
ARE TO_ 5 IN THE LOCKED
ED
A" TRACK_
MOUNTED UNITS
NOTE: CABINETS ARE FOR DISPLAY PURPOSES ONLY.
ALL CONSUMER TRANSACTIONS OCCUR AT SALES STATIONS
WHICH ARE COMPLIANT WITH TITLE 24 REQUIREMENTS.
TRACK
T I Co TRACK
C 118681(0 ) —
MENDING BRACKET
l 1 186 813 ; -�
-- NO. 8 x 0.62 PAN HEAD SCREW
TNROUCsN BOTTOf" HOLE AT END
OF TRACK INTO 1"1'END:NG BRACKET
T -1 6 TRACK D -- SCALE. N.T.S. -
c T -16 TRACK DETAIL
NO. 10 x 1 114"
TRUSS +4E AD
SCREWS ON 17
1/2 "CENTERS.
THROUGH
ALUMINIUM TRACK
INTO STUD AND
BLOCKING
GYP. BOARD
� �RpytD
PR 2 � 2Q4�
A
Y
i
I �
i
t:
7
~ ZF b
��
DO
22
L o
i
3 • LL„
v� •
v�
N
�y
s
a
w
■
I
PPo,kCT
04071.000
DAR
01/01/04
DR AWN
LY
CHECc•:: �— 1
9 ��
+"slo
I
I �
I
I
APR - 1 2004
i
SHf E ''TL E ^1
ElEVAT101�
. =T
S►�f E'
�
i
N
i
. r-.. .. .�.... .. .. .. .w... � .- .p.+.. .•.niyy�w.�.��.�yr..,,.... ♦� �w ^+.r�r. .n .w.�y�rw +��
2x WOOD BLOCKING
SCREWED TO STUDS
W/ 2" SELF TAPPING
16" O.C. FINE THREA
DRYWALL SCREWS
CUSTOM
•
b ._ S '
rl 01 r` /I f1I r\ A r11 f A f f A
I I
�I
BACK ROOM COUNTER
SCALE: 3/8" = I' -0"
5 ,_ 3 1,
in
N
(V
1' -4 2 1 -6" C_4"
MANAGER'S STATION ELEVATION
5CALE: 3/8" = I' -0"
CTRICAL METALLIC TUBING
(EMT) ONLY.
UNDERSIDE OF FLOOR OR
SIZE (01A.)
L(MAX HEIGHT)
1/ 211
41-001
` 2 / 11
3/4
5 1
1 11
6 1_ rill
SETTING TUBE.
,
SEE MAX. HEIGHT SCHEDULE.
211
121 -711
/'�
2 -1/2
1fv 1_G11
3 "
20 1 .2 11
4 26 -0"
0 ls�
NOTES
INSTALL BOLT TO
SECURE TUBE TO
THE OTHER TUBES
SHALL LAP ONE-
ANOTHER 4" MIN.
IN FULLY EXTENDED
POSITION.
STRUTS OTHER THAN
E,M.T. MAY REQUIRE '
ENGR. CALCULATION
NOTES
(1) 1/4 THE LENGTH
OF THE END RUNNER
WHICHEVER 15 LEAST.
(2) NAILS is ENDS OF
HORIZ. STRUTS ARE
TO BE PLACED W/ NAIL
HEAD TOWARD q OF
SPAN OF 5TRUT.
12 GA. HANGER WIRE
MILL 'l 71,0 1 M 71 WILIA
NOTES
1. ALL 2'X4' L6HT FIXTURE 4 2'X2' HVAC AIR
REGISTERS SHALL BE SUPPORTED BY 12 G
HANGER WIRES WITHN 3" OF EACH CORNER
AND TWO (2) HANGER WIRES (SLACK)
AT DIAGONAL CORNERS, CEILING SYSTEM
SHALL NOT SUPPORT OTHER ITEMS.
2. WIRES TO PEDANT MOUNTE FIXTURES
SHALL BE 9 GUAGE AND FIX TURE5
SHALL BE INDEPENDANTL
SUPPORTED BY BUILDING
STRUCTURES _
CROSS RUNNER
Ar-MATIr'AI PANFI
TYPICAL: 12 GA. VERTICAL HANGER WIRE
0 4' -0" EA. WAY W/ MIN. 3 TIGHT TURNS
IN 1 1/2" BOTH ENDS OF WIRE
INSTALL COMPRESSION STRUT a 12' -0"
EA. DIRECTION OR EVERY 144 5F. OF
CEILING AREA PER UBC 5TD, 41 -18
LOCATE 6 SPLAY WIRE LOCATION SEE Al -1
_I2 GA. SPLAY WIRE 612' -0" CC EA WAY
W/ MIN 4 TIGHT TURNS IN 11/2" BOTH
ENDS OF WIRE. INSTALL IN 4 DIRECTIONS 0
90' ANGLE TO EACH, TYPICAL
TYPICAL: 3/4" X 3/4" ANGLE
BRACE * 45 DEGREE ANGLE. TYPICAL: 12 GA.
ATTACH TO FLOATING GRID 4 VERTICAL WIRE
AND STATIONARY GRID WITH 4' EA. WAY
1/2" X 0 12 SELF - TAPPING SCREW. —,
AP "VID
R 2 � zooa
p,P
MAIN RUNNER
2' O.G. TO
RECE I vE NEW
ARMSTRONG
CEILING.
DETAIL @ ACCENT CEILIN GRO55 RUNNER
SCALE N.T.S.
COMPRESSION STRUT
RUNNER TEE5
FIRST WIRE
- NO. 12 GAUGE WIRE HANGERS AT
4' -0" O.C. EACH WAY.
4 NO. 12 WIRES SPLAYED 45
degrees IN 4 DIRECTIONS SO
degrees APART.
MAX MA
WALL 6 _U 7�._pO» i ,_0p» 6 *--0»
MAX. 1`1ASc. MAX
NOTE: COMPLIES LOTH UBC 25 -2: SEE SHEET 4- 5`DE7AIL A
FOR 51=ECIFICATION INFO.
4 DETAIL 5 @ ACCENT CEILING
MAIN ' » T`'AICAL: 3'4"
2'_ 4�'0» r BRACE • 45 DEGREE 4NG,_E. �— RUNNER it 2
CROSS RIANER `�"C, » �` ,-' A "AC:w TO FLOAT GR ^ 4 C C 'C
24' -
:11 (M AX.) FROM BRACING `� 04 3TAT GRID w RECE /E NE,,
WIRES TO C ,055 RANKERS 1 X 91 2 SELF- TAPP'NG SGREw - +R?
CE _ ING
: 6) CXTAL �AC�T _ � DETAL @ ACCENT CEO
SCALE N.T.S. SCALE N. -
'r
.s
4
•r
MAIN RUNNER
CRO55 RUNNER
DETAIL @ ACCENT CEILING
7 SCALE N.T.S.
12 GA. HANGER WIRE MIN. 3 TIGHT TURNS AT TOP
" c„ AND BOTTOM OF WIRE.
MAX. - MAIN OR CROSS RUNNERS $ MAX.
OTE (1) - OR NOTE (1)
HORIZ. SPACER BAR W/ HORIZ. 6d
RING SHANK NAIL (SEE NOTE 2)
ALTERNATE LOCATION WITHOUT
NAIL NOTCHING PERMITTED ONLY --�—*
is RWVER
ACOUSTICAL PANEL
FOR RIVET a ALL MEMBERS
ONE WALL (NO RIVET)
PERIMETER MEMBER * STARTER 4 OPP. WALLS
MTL. ATTACHMENT - 1 1 " MIN. EMBEDMENT,
OPPOSITE WALLS
Ll
z
all,
v
z
a
NQ
it
F
4" +
E
M �
Ira; » ,5
IFS
a
ail
n
Ip p,
� z o
�,_
��o
H
a�
v
3 W.
c
in
o ILI I�
IOWA
a
O z,
H �
T ,A*r
01072.000 01/01/04
(1QAMN
LY 9
I QE - v+SED
%R I v
APR - 1 2004
11 cEmm
UNDERSIDE OF FLOOR OR
ROOF STRUCTURE ABOVE.
MTAU
NO. 12 GA. VERTICAL WIRE
HAWGER, TRUE CEILING
GRID LEVEL PRIOR TO
SETTING TUBE.
,
SEE MAX. HEIGHT SCHEDULE.
DRILL 5/32" HOLE
IN 4 INSTALL 1/8"
BOLT 4 LOCK-
ING NUT.
EMT. SLEEVE -
'
SLOT CUT.
4
•r
MAIN RUNNER
CRO55 RUNNER
DETAIL @ ACCENT CEILING
7 SCALE N.T.S.
12 GA. HANGER WIRE MIN. 3 TIGHT TURNS AT TOP
" c„ AND BOTTOM OF WIRE.
MAX. - MAIN OR CROSS RUNNERS $ MAX.
OTE (1) - OR NOTE (1)
HORIZ. SPACER BAR W/ HORIZ. 6d
RING SHANK NAIL (SEE NOTE 2)
ALTERNATE LOCATION WITHOUT
NAIL NOTCHING PERMITTED ONLY --�—*
is RWVER
ACOUSTICAL PANEL
FOR RIVET a ALL MEMBERS
ONE WALL (NO RIVET)
PERIMETER MEMBER * STARTER 4 OPP. WALLS
MTL. ATTACHMENT - 1 1 " MIN. EMBEDMENT,
OPPOSITE WALLS
Ll
z
all,
v
z
a
NQ
it
F
4" +
E
M �
Ira; » ,5
IFS
a
ail
n
Ip p,
� z o
�,_
��o
H
a�
v
3 W.
c
in
o ILI I�
IOWA
a
O z,
H �
T ,A*r
01072.000 01/01/04
(1QAMN
LY 9
I QE - v+SED
%R I v
APR - 1 2004
11 cEmm
,i
ADJACENT WALLS
MTAU
A�7
r
,i
ADJACENT WALLS
r
PANEL 'A'
M /120 -MOLT, 3-PHASE, 4 -WIRE
225 -AMP MAIN LUG
DESCRIPTION
FI=RE LOAD
T P POLE CASH REGISTER
&>jM& E (NOT ALL FIXTURES USED)
KEYED
NOTE
10 1
REF LOAD BREAKER
NO AMPS P AMP
9.0 1 20
LOAD
TYPE
R
NOTES: EXISTING PANELBOARD WITH 200 -AMP FEEDER BY LANDLORD.
PROVIDE NEW PANELBOARD COVER.
PHASE AMPS LOAD LOAD REF KEYED
A 6 C TYPE AMPS NO NO TE
15.0 R 20 1 6.0 101
LOAD
DESCRIPTION
AEC - CAT S DATA HUB
CKT
NO
2
3
REC - T P POLE CASH REGISTER
TYPE
101
1
9.0
1
20
R
62
15.0
RECESSED
R
20
1
6.0
SHEET E -3, KEYED NOTE J6.
101
REC - SUPPORT SHIES CASH REGISTER
4
5
REC - SUPPORT PRE -PAID
2
101
2'x4' RECESSED LIGHT AND
BATTERY PACK
9.0
1
20
R
RECESSED
"METAL.UX" 2GR8232A- UNV -EB81
EMERGENCY BALLASTS - IOTA 124
15.0
R
20
1
6.0
101
FUSIBLE DISCONNECT SWITCH, SIZE AS NOTED
REC - CONSUMER
6
7
REC - CASH REGISTER
EXISTING
101
LARGEST MOTOR
4.5
1
20
R
9.0
3
W
R
20
1
4.5
2
101
120
REC - SALES AREA
8
9
REC - SALES AREA
2. DEVICE AND COVERPLATES COLOR PER NOTES 1 AND 2 ABOVE. SEE
101
ELECTRONIC BALLASTS
6.0
1
20
R
4g ISOLATED GROUND MARE
11.6
FOR CLARITY, WIRING MARKS ARE 94OWN ON THE HOMERUN ONLY.
L
20
1
5.6
2
100
120
T- MOBILE SIGN
10
11
LIGHTS & REC - WINDOW DISPLAYS
101
2.8
1
20
W
5
5.8
R
20
1
3.0
RECESSED
101
REC - DESK
12
13
LIGHTS - SALES BACK ROOM
101
8.8
1
20
L
11.8
3
R
20
1
3.o
100
AEC - BACK ROOM
14
15
TRACK LIGHTS
EXIT LIGHT UNIVERSAL RED FACE
101
16.0
2
20
T
17.5
"JUNO" 2- CIRCUIT, TRAC -LITES
R
20
1
1.5
101
120
REC - MICROWAVE
16
17
TRACK LIGHTS
101
1 16.0
+
++
T
19.0
R
20
1
3.0
101
REC - RERRWERATOR
18
19
REC - DESK /TRAINING
101
6.0
1
20
R
41.0
A
40
3
35.0
100
C UNIT
20
21
BLANK
"METALUX" CR- 232 -A- 120 -EB81
ELECTRONIC BALLASTS
FLU. 32W
2
62
35.0
SURFACE
A
++
+
35.0
100
C UNR
22
23
BLANK
1'x4' SURFACE WRAP AND
FLU. 32W
2
62
120
SURFACE
"METALUX" CR- 232 -A- 120 -EB81
EMERGENCY BALLAST - 10DA 124
35.0
A
•+
+
35.0
100
C UNIT
24
251
0.0
26
27
0.0
28
29
0.0
30
31
0.0
32
33
0.0
34
35
0.0
36
37
0.0
38
39
0.0
40
41
0.0
42
PANEL TOTALS:
1
77 1
79 1
75 1
5% DIFFERENCE
03126104
N.E.C. DEMAND CALCULATION
LIGHTING AN OTHER CONTINUOUS LOAD:
TRACK LIGHTING:
SHOW WINDOWS:
RECEPTACLE LOAD:
KITCHEN EQUIPMENT LOAD:
HEATING (COINCIDENTAL) LOAD:
MOTORS AND OTHER NON - CONTINUOUS OR MISCELLANEOUS LOAD:
LARGEST MOTOR LOAD:
TOTALS:
ACTUAL
ANA
1.7
3.8
0.3
9.2
0.0
0.0
8.3
4.3
27.7
DEMAND
FACTOR
125%
N/A
N/A
1002
100%
100%
100%
1252
119%
DEMAND
KVA
2.2
3.8
4.0
9.2
0.0
0.0
8.3
5.4
32.9
ExNudes track and show window lighting.
Length of track: 24 ft
Length of show window: 20 ft
1 00% of the first 10 WA. plus 50% over 10 WA.
Booed on 0 piece(s) of equipment.
Includes space heat in excess of cooling and other electric hoot.
AN other hods excluding longest motor lood.
MINIMUM 3 -PHASE FEEDER: 92 -AMPS
FWTM
&>jM& E (NOT ALL FIXTURES USED)
TYPE
SYMBOLS
DESCRIPTION
LAMP
WATT
VOLT
MOUNTING
MANUFACTUER & MODEL
TYPE
N0.
1
2'x4' RECESSED LIGHT W/
ELECTRONIC BALLASTS
FLU. 32W
2
62
120
RECESSED
"METALUX" 2GR8232A- UNV -EB81
W /SYL F032/735 WHIPS
4 -PLEX WALL MOUNTED JACK FOR CASH PODS AND PRODUCTS ISLAND, REFER TO
SHEET E -3, KEYED NOTE J6.
ZS
P.O.S DATA OUTLET WITH 3/4" CONDUIT TO DATA TERMINAL. 15" A.F.F.
=
TELEPHONE OUTLET WITH 3/4" CONDUIT TO TELEPHONE BACKBOARD. 15" A.F.F.
2
2'x4' RECESSED LIGHT AND
BATTERY PACK
FLU. 32W
2
62
120
RECESSED
"METAL.UX" 2GR8232A- UNV -EB81
EMERGENCY BALLASTS - IOTA 124
PANELBOARD
CIRCUIT BREAKER
EP
FUSIBLE DISCONNECT SWITCH, SIZE AS NOTED
W /SYL F032/735 LAMPS
NON- FUSIBLE DISCONNECT SWITCH, SIZE AS NOTED
(E)
EXISTING
LM
LARGEST MOTOR
(N)
NEW
A.F.F.
ABOVE FINISHED FLOOR
FLA
3
W
WATTS
ML
2'x2' RECESSED LIGHT W/
FLU. 32W
2
62
120
RECESSED
"LIGHTOLIER" DPA2G9LS2U6 -120
NOTES 1. SUBSCRIPT LETTER NEXT TO THE ABOVE SYMBOLS. INDICATES DEVICE
CONTROLLED.
2. DEVICE AND COVERPLATES COLOR PER NOTES 1 AND 2 ABOVE. SEE
ARCHITECTURAL DRAWING FOR EXACT LOCATIONS OF OUTLETS, UNLESS NOTED.
ELECTRONIC BALLASTS
EXTERIOR LOCATIONS SHALL BE GROUNDED FAULT TYPE (GFI).
4. DASHED LINE TYPE INDICATES EXISTING CONDITIONS.
UNGROUNDED CIRCUIT WIRE. (HOT)
GROUNDED CIRCUIT MARE. (NEUTRAL)
4g ISOLATED GROUND MARE
W /SYL F8032 /735 /ECO LAMPS
FOR CLARITY, WIRING MARKS ARE 94OWN ON THE HOMERUN ONLY.
4
RUN TO THE FINAL CONNECTION OF ANY DEVICE SERVED.
2'x2' RECESSED LIGHT AND
BATTERY PACK
FLU. 32W
2
62
120
RECESSED
"LIGHTOLIER" DPA2G9LS2U6 -120
EMERGENCY BALLAST - IOTA 124
w /SYL F8032 /735 /ECO LAMPS
5
RECESSED DOWNLIGHT
W /SPECULAR CLEAR ALZAK
FLU. 32W
1
37
120
RECESSED
"CAPRI"CM6 /FV26/32/42U/V65
REFLECTOR
W /SYL CF32DT /E /IN/ 835 LAMPS
6
EXIT SIGN W /BATTERY
LED
3
120
CEUNG OR
"SUREUTE" LPX70RWH LED
BACK -UP
WALL.
EXIT LIGHT UNIVERSAL RED FACE
TRACK LIGHT FIXTURE WITH
"JUNO" 2- CIRCUIT, TRAC -LITES
7
TRACK (LENGTH AS SHOWN)
5O/FT
120
CEILING
TRAC SYSTEM, 'JUNG' T620WH
WITH 5OPAR20 /HAL /SPL /NFL/
RP -120 LAMP
AL
A& If F9ft
f
v run M
9
1'x4' SURFACE WRAP W/
"METALUX" CR- 232 -A- 120 -EB81
ELECTRONIC BALLASTS
FLU. 32W
2
62
120
SURFACE
l� EQUAL) W /SYL F032/735
10
1'x4' SURFACE WRAP AND
FLU. 32W
2
62
120
SURFACE
"METALUX" CR- 232 -A- 120 -EB81
EMERGENCY BALLAST - 10DA 124
BATTERY PACK
(OR EQUAL)W /SYL F032/735 LAMPS
SYMBOLS AM NOTES
SYMBOLS
DESCRIPTION
$
SINGLE POLE TOGGLE SWITCH, 20 AMP, 120V. 36" A.F.F.
$Z
DOUBLE PLOE, SINGLE THROW SWITCH 20 AMP, 120V. 36" A.F.F.
$3
THREE WAY SWITCH, 20 AMP, 120V. 36" A.F.F.
$m
MOTOR RATED SWITCH, H.P. RATED. 36" A.F.F.
TELE /POWER POLE WITH DEVICES AS INDICATED
SINGLE RECEPTACLE, NEMA RATING A NOTED
$
DUPLEX RECEPTACLE, 20 AMP, 120V GROUNDING TYPE, =(:�: I.G. TYPE
=0:
DOUBLE DUPLEX RECEPTACLE, 20 AMP, 120V GROUNDING TYPE, 40 I.G. TYPE
A
CEILING MOUNTED DUPLEX RECEPTACLE, SAME AS ABOVE
4 -PLEX WALL MOUNTED JACK FOR CASH PODS AND PRODUCTS ISLAND, REFER TO
SHEET E -3, KEYED NOTE J6.
ZS
P.O.S DATA OUTLET WITH 3/4" CONDUIT TO DATA TERMINAL. 15" A.F.F.
=
TELEPHONE OUTLET WITH 3/4" CONDUIT TO TELEPHONE BACKBOARD. 15" A.F.F.
FLOOR TYPE DUPLEX RECEPTACLE, 20A GROUNDING TYPE
SPECIAL PURPOSE OUTLET OR DIRECT CONNECTION
M
UTIUTY METER
MOTOR OR CEILING EXHAUST FAN
JUNCTION BOX TO SUIT THE FIELD CONDITIONS
PANELBOARD
CIRCUIT BREAKER
EP
FUSIBLE DISCONNECT SWITCH, SIZE AS NOTED
Q�
NON- FUSIBLE DISCONNECT SWITCH, SIZE AS NOTED
(E)
EXISTING
LM
LARGEST MOTOR
(N)
NEW
A.F.F.
ABOVE FINISHED FLOOR
FLA
FULL LOAD AMPS
W
WATTS
ML
MOTOR LOAD
A
AMPS
LCL
LONG CONTINUOUS LOAD
NOTES 1. SUBSCRIPT LETTER NEXT TO THE ABOVE SYMBOLS. INDICATES DEVICE
CONTROLLED.
2. DEVICE AND COVERPLATES COLOR PER NOTES 1 AND 2 ABOVE. SEE
ARCHITECTURAL DRAWING FOR EXACT LOCATIONS OF OUTLETS, UNLESS NOTED.
3. RECEPTACLES IN BATHROOMS, LAUNDRY ROOMS, AND KITCHEN SINK AND
EXTERIOR LOCATIONS SHALL BE GROUNDED FAULT TYPE (GFI).
4. DASHED LINE TYPE INDICATES EXISTING CONDITIONS.
UNGROUNDED CIRCUIT WIRE. (HOT)
GROUNDED CIRCUIT MARE. (NEUTRAL)
4g ISOLATED GROUND MARE
GROUND WIRE
FOR CLARITY, WIRING MARKS ARE 94OWN ON THE HOMERUN ONLY.
CONTRACTOR SHALL MAINTAIN THE CONDUCTOR QUANTITY THROUGHOUT THE
RUN TO THE FINAL CONNECTION OF ANY DEVICE SERVED.
NO7'E8:
I. ALL RECEPTACLES AND SWITCH COVERPUIES ON P1 FINISH
SHALL BE WHITE.
2. ALL RECEPTACLES AND SWITCH COVERPLATES ON P2 FINISH
SHALL BE BLACK.
3. LIGHT SWITCH AND POSITION AND CIRCUIT ALLOCATION
TO BE DETERMINED, MOUNT All SWITCHES 448 O.C. A.F.F.
SPECIFICATIONS
I. THE ELECTRICAL DRAWINGS, SPECIFICATIONS AND GENERAL NOTES DESCRIBE THE RECOMMENDED SCOPE OF WORK
AND SHALL BE USED FOR THE PURPOSE OF BIDDING, BUILDING DEPARTMENT REVIEW AND TO SECURE THE NECESSARY
CONSTRUCTION PERMIT ONLY. CONTRACTOR SHAD. PROVIDE CONSTRUCTION DRAWINGS AND OBTAIN WRITTEN APPROVAL OF
ALL INSPECTION AGENCIES AND UTILITY COMPANIES PRIOR TO START OF WORK.
2. THE ELECTRICAL DRAWINGS, CONDUIT RUNS, WIRING, LIGHTING FIXTURES AND DEVICE LOCATIONS ARE DIAGRAMMATIC
ONLY. DO NOT SCALE THE ELECTRICAL DRAWINGS TO DETERMINE THE LOCATION OF EQUIPMENT, LIGHTING FIXTURES,
DEVICES OR OUTLETS.
3. REFER TO THE ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATION OF ALL LIGHTING FIXTURES, CEILING
MOUNTED OUTLETS AND EQUIPMENT.
4. COORDINATE THE PLACEMENT AND MOUNTING HEIGHT OF ALL DEVICES WITH THE ARCHITECTURAL DRAWINGS
ELEVATIONS PRIOR TO ROUGH -IN WORK.
5. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FURNISH APPROVED LIGHTING FIXTURES OF THE TYPE REQUIRED FOR
MOUNTING IN RELATED CEIUNGS. PROVIDE FIXTURES COMPLETE WITH NECESSARY MOUNTING HARDWARE AND
ACCESSORIES.
6. PORTIONS OF THE CEILING SYSTEMS MAY BE INACCESSIBLE. THEREFORE, THE CONTRACTOR SHALL STRATEGICALLY
LOCATE ALL JUNCTION BOXES IN AN ACCESSIBLE CEILING SPACE. ALL LIGHTING FIXTURE WIRING, BALLASTS, J- BOXES,
ETC. SHALL BE ACCESSIBLE FROM FIXTURE OPENING.
7. MAKE ALL FINAL CONNECTIONS TO OWNER FURNISHED EQUIPMENT, UNLESS OTHERWISE NOTED. VERIFY ELECTRICAL
CHARACTERISTICS AND UL LISTING PRIOR TO CONNECTION.
8. ELECTRICAL OUTLETS ON OPPOSITE SIDES OF FIRE -RATED WALLS AND PARTITIONS MUST BE SEPARATED BY DISTANCE
OF 24 IN. HORIZONTAL.
9. PROVIDE AN ADDITIONAL JUNCTION BOX (SIZE AS REQUIRED) WHERE THE NUMBER OF CONDUCTORS EXCEEDS THE
MAXIMUM ALLOWED FOR A GIVEN JUNCTION POINT OR OUTLET.
10. CONDUCTORS SHALL BE COPPER THHN/THWN 600 VOLT INSULATION UNLESS OTHERWISE NOTED. USE PROPER
TEMPERATURE RATING OF CONDUCTORS BASED ON THE AMBIENT AIR TEMPERATURE WHERE CONDUCTORS ARE BEING USED.
HIGH AMPACITY CONDUCTOR AND LARGER RACEWAY SHALL BE PROVIDED TO OFFSET THE AMPACITY CORRECTION FACTORS
AS INDICATED IN NEC TABLE 310 AND ELSEWHERE PER CODE.
11. ALL FLUORESCENT BALLASTS AND LAMPS SHALL BE ENERGY SAVING TYPE.
12. SEAL ALL PENETRATIONS THROUGH FIRE RATED WALLS, CEILINGS, FLOORS. ETC., TO MAINTAIN THE FIRE RATING.
FURNISH AND INSTALL FIRE RATED ENCLOSURE FOR ALL EQUIPMENT PENETRATING INTO FIRE RATED ENVELOPES, SPACES,
ETC.
13. ALL ELECTRICAL EQUIPMENT SHALL BE BRACED OR ANCHORED TO RESIST A HORIZONTAL FORCE ACTING IN ANY
DIRECTION USING THE FOLLOWING CRITERIA.
v) FIXED EQUIPMENT ON GRADE 33% OF OPERATING WEIGHT.
b) FIXED EQUIPMENT ON STRUCTURE 50% OF OPERATING WEIGHT.
c) FOR FLEXIBLE MOUNTED EQUIPMENT, USE 2 TIMES THE ABOVE VALUE.
d) SIMULTANEOUS VERTICAL FORCE - USE 1/3 TIMES HORIZONTAL FORCE.
14. ALL EXISTING CONDITIONS ARE NOT INDICATED ON THE DRAWINGS. CONTRACTOR SHALL CAREFULLY EXAMINE THE
EXISTING INSTALLATION AND ALL PROJECT DRAWINGS TO BECOME FAMILIAR WITH THE SCOPE OF WORK. NO ADDITIONAL
CHARGES WILL BE ALLOWED DUE TO THE LACK OF A PRE -BID SITE EXAMINATION.
15. CONDUIT, WIREWAYS, ETC., SHALL BE BRACED IN ACCORDANCE WITH SMACNA.
16. ALL FIXTURES TO BE INSTALLED PER UBC SECTION 2804. FIXTURE SUPPORT BY NO. 12 GAUGE HUNGERS
ATTACHED TO GRID MEMBERS WITHIN THREE INCHES OF EACH CORNER OF EACH FIXTURE.
17. LIGHTING FIXTURES AND CONDUITS SHALL BE SUPPORTED DIRECTLY BY WIRES TO THE STRUCTURE ABOVE.
EXCEPTION:
RECESSED LIGHTING FIXTURES NOT OVER 56 LBS. IN WEIGHT AND SUSPENDED OR PENDANT HUNG FIXTURES NOT OVER
20 LBS. IN WEIGHT MAY BE SUPPORTED AND ATTACHED DIRECTLY TO THE CEILING SYSTEM RUNNERS BY A POSITIVE
ATTACHMENT SUCH AS SCREWS OR BOLTS. AIR DIFFUSERS WHICH WEIGH NOT MORE THAN 20 LBS. AND WHICH RECEIVE
NO TRIBUTARY LOADING FROM DUCTWORK MAY BE POSITIVELY ATTACHED BY THE CEILING RUNNERS.
THE ABOVE REQUIREMENTS ARE BASED ON UBC STANDARD 25 -2. OTHER METHODS MAY BE USED, PROVIDED THEY ARE
SUBSTANTIATED BY DESIGN CALCULATIONS USING THE LOADS SPECIFIED IN CHAPTER 25. THE APPROVED BUILDING PLANS
SHALL CLEARLY IDENTIFY ALL ELEMENTS AND SHOW ALL DETAILS OF THE BRACING SYSTEMS.
18. BRANCH CONTROL CIRCUITING AND WIRE COUNT MAY NOT BE INDICATED ON THESE PLANS. CONTRACTOR IS
RESPONSIBLE TO COMPLETE THE BRANCH CIRCUIT WIRING IN ACCORDANCE WITH PLAN NOTES AND AS PERMITTED BY
AUTHORITY. CONTRACTOR SHALL SUBMIT AS -BUILT DRAWINGS AS A PART OF RECORD DRAWING SUBMITTAL TO ARCHITECT
AND AUTHORITY HAVING JURISDICTION (AHJ).
19. THE ELECTRICAL INSTALLATION SHALL COMPLY WITH THE NATIONAL ELECTRICAL CODE (NEC) ADOPTED BY THE
JURISDICTION AND INCLUDING ANY LOCAL SUPPLEMENTS.
20. THE ELECTR INSTALLATION WORK SHALL COMPLY WITH ALL LOCAL, STATE AND NATIONAL CODES, LAWS AND
ORDINANCES APPLICABLE TO ELECTRICAL WORK.
21. ALL MATERIAL AND EQUIPMENT FURNISHED AND INSTALLED UNDER THIS CONTRACT SHALL BE FREE FROM DEFECTS,
AND SHILL BE GUARANTEED FOR A PERIOD OF ONE YEAR FROM DATE OF FINAL ACCEPTANCE BY OWNER OR HIS
REPRESENTATIVE.
22. ALL WORK TO BE EXECUTED IN WORK MANLIKE MANNER AND SHALL PRESENT A NEAT MECHANICAL APPEARANCE
W 14EN COMPLETED.
23. REMOVE AND DISPOSE OF ALL UNUSED OR ABANDONDED CONSTRUCTION MATERIALS.
24. METAL CLAD CABLE SHALL BE PERMITTED FOR BRANCH CIRCUITING PER NEC.
25. IT SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO VERIFY ALL EXISTING LIGHT FIXTURES,
DEVICES AND EQUIPMENT SCHEDULED FOR REMOVAL, AND DISCONNECT AT THEIR POWER SOURCE PRIOR TO ANY
DEMOLITION WORK. THE CONTRACTOR SHALL TAKE ALL PRECAUTIONARY MEASURES NECESSARY TO ELIMINATE ANY
ELECTRICAL HAZARDS THAT MAY ARISE DURING THE DEMOLITION PHASE OF WORK.
26. THE ELECTRICAL CONTRACTOR SHALL VERIFY AND INSPECT ALL EXISTING CONDITIONS AND ELECTRICAL EQUIPMENT
AND MAKE ALL NECESSARY MODIFICATIONS AND /OR ADJUSTMENTS AS REQUIRED FOR THE PROPER OPERATION OF
EQUIPMENT AND COMPUANCE WITH ALL APPLICABLE CODES.
27. ALL DEVICES AND COVERPLATES SHALL BE DECOR TYPE.
28. ALL CONDUITS SFIALL CONTAIN AN EQUIPMENT GROUND CONDUCTOR, SIZE IN ACCORDANCE WITH ARTICLE 250 OF
THE NEC.
PLRMIT AND
APPROVAL
REQUIRED
A
t =6 a
I L �
100 EXISTING CIRCUIT TO REMAIN.
101 REMOVE EXISTING CIRCUIT AND RE -USE BREAKER FOR NEW CIRCUIT AS SHOWN.
W
,&.
A
a • i
r
1/2
3 #12:A -11,13
1 #12:GND -
i;
I�
;c
�I 1
F
Yk
1 1a
1
S
1/2"c
3# 12:A -15,17
1 # 12:GND
UGHTM PLAN
r
c_z _: "T "as
--I TZ
A. THE ELECTRICAL CONTRACTOR SHALL ADJUST, RELOCATE, OR
PROVIDE NEW FIXTURES AS REQUIRED TO ACCOMMODATE NEW
CONSTRUCTION. PROVIDE AND INSTALL JUNCTION BOXES,
FITTINGS, CONDUITS AND WIRING AS NECESSARY FOR A
COMPLETE INSTALLATION IN COMFORMANCE WITH THE NATIONAL
ELECTRIC CODE AND OTHER LOCAL CODES. THE ELECTRICAL.
CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL
PERMITS AND INSPECTIONS REQUIRED. COORDINATE ELECTRICAL
REQUIREMENTS AND CONDUIT ROUTING WITH OTHER TRADES.
B. THE ELECTRICAL CONTRACTOR SHALL VERIFY ELECTRICAL LOADS
ON EXISTING CIRCUIT(S) AND PANELBOARD(S) PRIOR TO MAKING
ANY MODIFICATIONS TO ENSURE ADEQUATE CAPACITY FOR NEW
DEVICES AND LIGHT FIXTURES. PROVIDE AND INSTALL CIRCUIT
BREAKERS OF THE SAME TYPE AND RATING IN THE EXISTING
PANELBOARD(S).
C. CONTRACTOR SHALL COORDINATE LOCATIONS OF RECEPTACLES
AND VOICE /DATA RECEPTACLES TO BE INSTALLED WITH TENANT.
MOUNT CONVENIENCE RECEPTACLES AND VOICE /DATA
RECEPTACLES AT 18" ABOVE FINISHED FLOOR. MEASUREMENTS
SHALL BE TO THE CENTER OF BOX.
D. FINAL ELECTRICAL MODIFICATIONS ARE TO BE COORDINATED WITH
GENERAL CONTRACTOR, io POSITION OF ALL ELECTRICAL CONTROL
DEVICES, SWITCHES, ALARM SENSORS, SECURITY CAMERAS,
THERMOSTATS, TELEPHONE JACKS, ETC.
E. PROVIDE EMPTY CONDUIT FROM VOICE /DATA JUNCTION BOX
WITH PULLSTRING TO ACCESSIBLE SPACE ABOVE CEILING.
F. WHERE DEMOLITION OF EXISTING DEVICES OCCURS, THE
CONTRACTOR SHALL REMOVE CONDUIT AND WIRE BACK TO
NEAREST UP— STREAM DEVICES OR JUNCTION BOX. INTERCEPT
AND EXTEND EXISTING CIRCUITS TO DOWSTREAM DEVICES SO
THEY REMAIN OPERATIONAL..
G. EXISTING ELECTRICAL DEVICES TO REMAIN AND BE PROTECTED,
UNLESS OTHERWISE NOTED.
H. COORDINATE WITH MECHANICAL CONTRACTOR AND PROVIDE
POWER AS REQUIRED TO MECHANICAL UNITS.
I. COORDINATE WITH THE LANDLORD— TENANT AGREEMENT TO
ENSURE COMPLIANCE WITH THE ELECTRICAL REQUIREMENTS FOR
TENANT'S CONSTRUCTION WORK.
s
KEYED NOTE&
(nxs SHEET ONLY)
2. EXISTING nweaocK FOR ca+rna OF r -MOBILE spa+.
3. PROVIDE AND INSTALL SPST, 120V. TOGGLE SWITCHES TO
CONTROL FRONT END LIGHTING AS FOLLOWS:
= GENERAL LIGHTING
= TRACK LIGHTS
= DAYLIGHT TRACK
= WINDOW DISPLAY LIGHTING
(LABEL EACH SWITCH)
4. CONNECT TO T— MOBILE SIGN. PROVIDE CONNECTION FOR EACH
SIGN, LETTER, OR LOGO.
5. VERIFY AND RE —USE EXISTING CIRCUIT AND ROUTE VIA THE
T— MOBILE SIGN TIME CLOCK LOCATED ADJACENT TO PANEL.
W. nrr r � r+
7. CONNECT EXHAUST FAN TO THE SWITCHED LEG OF THE CIRCUIT
SO THAT THE FAN OPERATES WHEN LIGHT IS ON.
NOtr
NQ�
MW 11=0 1 ANO IN ,
NOR , ;GWA FOR 609—
r n n
12. FURNISH AND INSTALL. BLOCKING FOR SURFACE MOUNTING OF
FIXTURE TO THE WIRE CEILING OF THE CAGE.
13. CONNECT BATTERY TO "HOT" SIDE OF SWITCH.
PARATE
PFRMIT AND
liz
QUIRED
r %
•
a
1
- ..� raw .r...a..ti• .. a T ... r. - ...n ...n .. - ..
2 CAT 5 DATA HUB
RE: E -3 -2 FOR 1/2
LAYOUT REQUIREMENTS ;
2112:A-2 ,
I 1 #12:GND
i
f 3 4 1 /2 "C
- 3# 12:A -16,18
1 #I2:GND
1
/
3# 12:A -1 3 -
1 2 C � 6 f
! r;
4# 12:A - 5,7,9 1/2-C"
_
1 12:GND I l -�' �� -�- 4#1$:4,6,8
f • 1 # 12:GND
E.i
9
7
c
wis-
l9
3
f ,
_6.
:
r I
-- - -- - - - --- - ---- -
___
v
1 POWER PLAN
6 1
r
L
(E)PANEL 'A' 1/20'C
2#' 12:A -12
6 2#12:A-19
1_#l2:GN0 _
f :a ,.1'
I 3
s �
�`
i1.
i
�i
a
7
I
A. THE ELECTRICAL CONTRACTOR SHALL ADJ UST, RELOCATE, OR
PROVIDE NEW FIXTURES AS REQUIRED TO ACCOMMODATE NEW
CONSTRUCTION. PROVIDE AND INSTALL JUNCTION BOXES,
FITTINGS, CONDUITS AND WIRING AS NECESSARY FOR A
COMPLETE INSTALLATION IN COMFORMMNCE WITH THE NATIONAL
ELECTRIC CODE AND OTHER LOCAL CODES. THE ELECTRICAL
CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL
PERMITS AND INSPECTIONS REQUIRED. COORDINATE ELECTRICAL
REQUIREMENTS AND CONDUIT ROUTING WITH OTHER TRADES.
B. THE ELECTRICAL CONTRACTOR SHALL VERIFY ELECTRICAL LOADS
ON EXISTING CIRCUIT(S) AND PANELBOARD(S) PRIOR TO MAKING
ANY MODIFICATIONS TO ENSURE ADEQUATE CAPACITY FOR NEW
DEVICES AND LIGHT FIXTURES. PROVIDE AND INSTALL CIRCUIT
BREAKERS OF THE SAME TYPE AND RATING IN THE EXISTING
PANELBOARU(S).
C. CONTRACTOR SHALL COORDINATE LOCATIONS OF RECEPTACLES
AND VOICE /DATA RECEPTACLES TO BE INSTALLED WITH TENANT.
MOUNT CONVENIENCE RECEPTACLES AND VOICE /DATA
RECEPTACLES AT 18" ABOVE FINISHED FLOOR. MEASUREMENTS
SHALL BE TO THE CENTER OF BOX.
D. FINAL ELECTRICAL MODIFICATIONS ARE To BE COORDINATED WITH
GENERAL CONTRACTOR, is POSITION OF ALL ELECTRICAL CONTROL
DEVICES, SWITCHES, ALARM SENSORS, SECURITY CAMERAS,
THERMOSTATS, TELEPHONE JACKS, ETC.
E. PROVIDE EMPTY CONDUIT FROM VOICE /DATA JUNCTION BOX
WITH PULLSTRING TO ACCESSIBLE SPACE ABOVE CEILING.
F. WHERE DEMOLITION OF EXISTING DEVICES OCCURS, THE
CONTRACTOR SHALL REMOVE CONDUIT AND WIRE BACK TO
NEAREST UP- STREAM DEVICES OR JUNCTION BOX. INTERCEPT
AND EXTEND EXISTING CIRCUITS TO DOWSTREAM DEVICES SO
THEY REMAIN OPERATIONAL.
G. EXISTING ELECTRICAL DEVICES TO REMAIN AND BE PROTECTED,
UNLESS OTHERWISE NOTED.
H. COORDINATE WITH MECHANICAL CONTRACTOR AND PROVIDE
POWER AS REQUIRED TO MECHANICAL UNITS.
I. COORDINATE WITH THE LANDLORD- TENANT AGREEMENT TO
ENSURE COMPLIANCE WITH THE ELECTRICAL REQUIREMENTS FOR
TENANT'S CONSTRUCTION WORK.
KEYED NOTE&
(n«s SHEET ONLY)
1 TELE /POWER POLE WITH 4 -PLEX JACK AND DUPLEX
RECEPTACLE FURNISHED BY OWNER, INSTALLED BY
CONTRACTOR. PROVIDE AND INSTALL APPROXIMATELY 3' -0"
OF SPLIT CORRUGATED INNERDUCT FROM CEILING TO TOP OF
POLE FOR CABLE WRAP.
2 CONTRACTOR SHALL FURNISH AND INSTALL 25 PAIR PHONE
CABLE FROM MAIN TELEPHONE DEMARCATION LOCATION TO
PHONE BOARD. PROVIDE 106 COPPER GROUND IN 1/2"
CONDUIT TO PANEL GROUND BAR.
3 MOUNT RECEPTACLE ABOVE COUNTER AND BEHIND
MICROWAVE. FIELD VERIFY LOCATION PRIOR TO ROUGH -IN.
4 MOUNT RECEPTACLE ABOVE COUNTER SPLASH PLATE. FIELD
VERIFY LOCATION PRIOR TO ROUGH -IN.
WT 1=11E
6 STORE — CABLE REQUIREMENTS AS FOB
(1) 4 —PLEX JACK AT EACH CASH POD (CASH
DESKS NEAR STORE FRONT)
(2) 4 -PLEX JACK AT EACH DOUBLE CASH POD
(CASH DESKS NEAR STORE FRONT)
(2) 4 -PLEX JACK AT EACH SALES SUPPORT
COUNTER (WHERE APPLICABLE)
(1) 4 -PLEX JACK AT EACH CUSTOMER CARE DESK (WHERE
APPLICABLE)
(1) 4 —PLEX JACK AT EACH PRODUCT ISLAND
(1) 4 —PLEX JACK AT EACH CONSUMER
(1) 4 —PLEX JACK AT EACH PROSUMER
(1) 4 —PLEX JACK AT EACH RSSK PODIUM (WHERE
APPLICABLE)
(1) 4 —PLEX JACK IN THE INVENTORY ROOM
(1) 4 —PLEX JACK AT THE MANAGER'S DESK /OFFICE.
COAXIAL CABLE AS REQUIRED PER THE POWER AND
COMMUNICATIONS DRAWING.
o) ALL CABLE TO BE 4 PAIR CAT -5E (PLENUM IF
REQUIRED BY CODE).
b) EACH 4 -PLEX LOCATION, THERE SHALL BE (3)
CAT -5E CABLES (PLENUM CABLE IF REQUIRED BY
CODE) TERMINATED ON A RJ45 4 - PLEX JACK (ALL
JACKS AND PLATES TO BE WHITE.) WIRE /LABEL AT
THE PATCH PANEL AND JACK AS FOLLOWS:
Wlem
(1) —BLANK
(I)—VOICE 1 —A
(1) — DATA 1 - 8
(1)— BACKUP 1 —C
I. CLEARLY MARK EACH AT BOTH THE LOCATION
PANEL AND JACK.
2 CAT
2. ALL THREE CABLES TO BE TERMINATED ON A
48 -PORT PATCH PANEL THAT MEETS
SPECIFICATIONS REQUIRED BY THE CABLE
SUPPLIER TO MEET CAT -5E STMNDARDS. EACH
PATCH PANEL MUST HAVE 5 TO 8 EXTRRA PORTS
FOR EXPANSION. WALL MOUNT EACH PATCH
PANEL WITHIN A SWING -OUT BRACKET ON THE
TELEPHONE ROOM'S WALLBOARD.
c) DATA PRODUCTS TO BE UTILIZED:
FOR FURNITURE:
LEVITON QUICKPORT SURFACE MOUNT HOUSINGS
MODEL 1 41089 -4WP
CONNECTORS:
LEVITON GIGAMAX CATEGORY 5e QUICKPORT
SNAP —IN CONNECTORS
MODEL f 5G108 —RW5
F .
LEVITON QUICKPORT SINGLE —GANG WALLPLATES
MODEL i 41080 -4WP
PATCH . MEL:
LEVITON UNIVERAL CATEGORY 5 AND GIGAMAX 5e
PATCH PANELS AND PATCH BLOCKS
MODEL 1 5G584 --U48
PATCH PANEL BRACKET:
LEVITON HINGED WALL -MOUNT BRACKETS
MODEL f 49251 -W62
M
BERKTEK CAT 5e COPPER CABLE
MODEL j LAN - MARK 350
7 REPLACE EXISTING RECEPTACLE AND COVERPLATE. CIRCUIT
AS SHOWN.
�r"4RATF
`.R-MIT AND
f
REQUIRED
a.. . +-. r._ n .. . +. .�,.• _. a.�._.y nw.a..v r -w ..- .�....A�� -aww.. r- i.....�.�
. ..» - .. .. v w.. •..r +..., r_ w M •w -..-. • u r+w+•w.M... -r-yn. �.M.w ... .�.n�l.i.w .. ...r.w. - ., rs. w w ...__. -. r r.r. ..-r. a.....�. -_ .-
5 DATA HUB LAYOUT
r7