Loading...
HomeMy WebLinkAboutPermit D04-114 - MONEYTREE - INTERIOR DEMOLITIONMONEY TREE, INC. 6720 FORT DENT WAY SUITE #140 D04 -114 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 2954900455 Address: 6720 FORT DENT WY TUKW Suite No: DEVELOPMENT PERMIT Permit Number: D04 -114 Issue Date: 05/05/2004 Permit Expires On: 11/01/2004 Tenant: Name: MONEYTREE, INC. Address: 5720 FORT DENT WY, TUKWILA WA Owner: Name: )OHN C RADOVICH LLC Address: 2000 124TH AVE NE #B 103, BELLEVUE WA Contact Person: Name: )OE STOY Address: EAST 2711 SPRAGUE, SPOKANE, WA Contractor: Name: BAKER CONSTRUCTION Address: 2711 E SPRAGUE AVE, SPOKANE, WA Contractor License No: BAKERCD066CZ Phone: Phone: 509 535 -3668 Phone: Expiration Date:04 /06/2006 DE SCRIPTION OF WORK: DEMOLITION OF ENTIRE INTERIOR OF EXISTING SUITE Value of Construction: $ $8,200.00 Fees Collected: $280.46 Type of Fire Protection: SPRINKLERS Uniform Building Code Edition: 1997 Type of Construction: VN Occupancy per UBC: 0016 blic Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: N Hauling: N Start Time: End Time: Land Altering: N Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: N Moving Oversize Load: N Start Time: End Time: Sanitary Side Sewer: N Sewer Main Extension: N Private: Public: Storm Drainage: N Street Use: N Profit: N Non - Profit: N Water Main Extension: N Private: Public: N Water Meter: ** Continued Next Page ** Pu doc: Devperm D04 -114 r.::,, ,..:t:r ;t a,.., :11d4V;:' tt; lrr.Z„ Printed: 05 -05 -2004 zz Z w 6U O 0 N D J ir- • LL w O 2 u. _• a �w 1- O zf- w • w co U� O — O H O • w. - O. ..z w = O~ z wyoit City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Permit Center Authorized Signature: Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating constr io or th :('erformance of work. I am authorized to sign and obtain this development permit. Signature: C /fir Date: Print Name: 9L/ /r This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doe: Devperm D04 -114 Printed: 05 -05 -2004 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 2954900455 Address: 6720 FORT DENT WY TUKW Suite No: Tenant: MONEYTREE, INC. PERMIT CONDITIONS Permit Number: D04 -114 Status: ISSUED Applied Date: 04/06/2004 Issue Date: 05/05/2004 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 3: Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (206- 835 - 1111). 4: All mechanical work shall be under separate permit issued by the City of Tukwila. 5: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any construction. These documents are to be maintained and available until final inspection approval is granted. 6: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 7: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. 8: ** *FIRE DEPARTMENT CONDITIONS * ** 9: The attached set of plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 10: Maintain fire extinguisher coverage throughout. 11: Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5) 12: Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 1207.3) 13: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (UFC 1207.3) 14: Exit hardware and marking shall meet the requirements of the Uniform Fire Code. (UFC 1207 -1212) 15: Aisles leading to required exits shall be provided from all portions of buildings. Aisles located within an accessible route of travel shall also comply with the Building Code requirements for accessibility. (UFC 1204.1) 16: Maintian sprinkler coverage per N.F.P.A. 13. Addition /relocation of walls, closets or partitions may require relocating and /or adding sprinkler heads. doc: Conditions ;:ltiii >t =ss� D04 -114 Printed: 05 -05 -2004 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 17: Sprinkler protection shall be extended to all areas where required, including all enclosed areas, below obstructions and under overhangs greater than four feet wide. (NFPA 13 -4- 5.5.3.1) 18: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recorgnized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1901) 19: Contact the Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1900 and #1901) 20: All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 21: Accumulation of combustible waste material is prohibited during the demolition phase of this project. Remove and properly dispose of all waste material prior to the close of the working day and as often throughout the day as needed. 22: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. 23: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 24: These plans were reviewed by Inspector 512. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. 25: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #1900) 26: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air - moving equipment upon detection of smoke in the main supply -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (UMC 608) 27: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #1900) 28: All new fire alarm systems or modifications to existing systems shall have the written approval of the Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1900) (UFC 1001.3) 29: Call the Tukwila Fire Department at 575 -4407 for approval of any system shut down. Have job site address, name and Tukwila Fire Department Job Number available to confirm shut down approval. (City Ordinance #1900) I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws doc: Conditions D04 -114 Printed: 05 -05 -2004 1 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 regulating construction or the performance of work. Signature: Print Name: Date: 5 -- -e* doc: Conditions 004 -114 Printed: 05 -05 -2004 ,,.MAR 30 '04 11:44t1 TUKWILA \DCD /PW CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 P.2'? Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Site Address: (..lZo r' r O04JT ►,cl'A -i 4- 140 Tenant Name: Pt0M•Tt2-0� ING• Property Owners Name: JG .A100`llG1.1 Mailing Address: 1,c9c7 (244' ¢sV6 ge % to3 � yt Go S AcT: .�. rte GLA 'D Pvt Qsc 1. CIS t, ttr1��t�Ji , ; :i y'; ',1'�,! ` Y.:' 1 "'Y '. 1`rl. �'111���j • .a ':, lj{I � {! ' i11'';'�1l�!�' j i J;13,1 "IJl ' p ' 7 � J''i,il' ' p•Ib � ,, J1I IISI'{n. A 1 ' { j qrl "' Lq fI I.t1 t al {iJ i (I u117 (. N t.td � tt , 1 .. f WJ , t 4; it�•� (fi M d4Y'1 it . is tl � .t ;;f'� l:i " "� tna« ,ti � ' . �, t, 1 ,.'' 7' 1 fll j �� v (J •.1i h i7tilQ � t x 111 . ..t v : r.I dl l' ,1l,1 ;71� l'l f , I �.a dt4• , •i {�' ; Iql `! p, . 1 1. . 1' r llf .1,1: 17 It11y1 d•1.9I� ,! ,i. ,1 '.13 LIy1I„ .'l rl ;iri •Il t01r1. L,.1,,,..�11,1, ld,.) c { 11 f 1 .li 1 ._,...faj .a , d 1� 1 �yyi 111 iltltll.,. , t 7 (Ib i t.�� i 4ll� , m,._..• 1 .M ,1.,,�', - _ �•,,„ YI.17. f r.,,,, a ii ), 1 p.�d�.11 King Co Assessor's Tax No.: o2 .73- Yfo --C) (51' Suite Number: 1 4o Floor: New Tenant; Jam:... Yes ❑ ,.No 4, 95 State Zip { {I) ..1.+,r d''11: X41 4i��:C;:�jU'i•...4 )41;144. .: MAR 30 '04 11 :45AM TUKWILA DCD /PW t 1• 't �, '1,� Nir,�• J . 't •,.. ,1 I ,� r ' t , ' •'f t( rat !dl,m,.�, 4�NP6"it ;1C�.. i' i�,,,, i,n,,,ili1'�1'rr;iF„iri9111 {�', litttu,f' 11rl, fr�l',,'"tr';'�,,.�`iG�t +Ip,lO, isle{ IIIII���� ,Mt�,�'i•t,la� ;'p:111:+ 00 Valuation of Project (contractor's bid price), $ F71.e;t:, P.3 /7 h r t',dMgNM tl ir36,, ' y1 rn d t •,fi ! n i ; rs , h„yy;rf,tt, , ter t:i i ll„ II ' .9! � lG,( 11 !J1� „ 1,, ,•tr tl,n it G I lG tt ".1 n!I; I ;. 1 ,I r „y4 „I' t �'1 „i 410,14,V►l Illl7 titlf; l '�1,' 1,1,00, ail, s ,l dC;4t�j�, ;�11'y,r . f tfU,IdNt, ,. ,�!'�ft�11'dit . n7r ;�:� tr., , U, �„4• vl'i ;a', �i, ,,,lr,�t, '13'llh,li�ln,,,,,Jl � }i '�'f ti r I,Af�,9 q, fl1 .111; ,j,a,., {,,.I�Iy1.ii140411 I:ii �S;;,lt Existing Building Valuation: $ Scope of Work (please provide detailed information): M O L (TIo ,.J eS rr I NTeg. tort,., Will there be new rack storage? ..Yes 'O.. No If "yes ", see Handout No. for requirements. 'r .: ' .• ..,,, . ,., „ , ,• ! ..; .. ; ' '', ;, . ;. istin , ,,, • , • •� g• •111,,,,.....',..1'....: , ', :'' t , 0 e ' ''; : ' xA , .•.1,, , , , . ; : Adttit9 ,�, }!>, ist� ',,,,, ; ;'..Strncttl d,.: , ^'' , � _ . K , . „ , ;: ,;, • t•'' �r„�n, • , ;�' ' ; :Ne : ,,,,,, ; .._, ti't'I . "'' • .,,.. ,t: °M: ' ;,e; "t if:'. -.,., ,;...,. ,•," �`ort�EKtt `b �, : N „ rr , tip;,,,, : I' '.;.. ,.pc , U •�; ., ,. i ' ;;+�Jcct� Pee 'atxc' •• r , :� ;,.. "."'1",":.... . � , _;T3G 41 lI' ,door; ., ••.•, • • ' ' '', 1'I 7 t 1Cjc] ' 2"0'Pl'oor•,' ..- , , •1 ..` . • • • ,.3i0 Floor' %: • "•, '.E14,6 ii,., ' , thrti•..•- .B'eseme (tt r Atth0h4dtl:inieeer. ; Detached' Gttrdgb' :. :',' • A chOd,, arbort,' "..,• • • ':Detached..C.a port; ' .'C.'over ok; ,0;13F "''• • UnGQv;Cned.peCI� • PLANNING DIVISION: Single - family building footprint (arch of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) For an Accessory dwelling, provide the following: Lot Area (sq ft):, Floor area of principal dwelling: Floor area for accessory dwelling: "'Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? [j ....Yes jg ..No If "yes ", explain: FIRE PROTECTION/RAZARDOUS MATERIALS: M.' Sprinklers ❑ ..Automatic Fire Alarm ..None ❑ . Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? .. Yes ❑ .. No Ij "yes'', attach list of materials and storage locations on a separare 8-1/2 x 1 1 paper indicating quantities and Material Safety Data Sheers. Uppllcochw Wtrmd appl,cauon (3.2003) ]x1003 ,,.....•. ,. :mote. et3r,i+A,, #: Luse+: ii.{ n��t, iia:. tn:: i�itC+ i.: r,:: �w�J +w:+kr';�an..•.u,�.�.•.wv,.�. Page 2 - MAR 30 '04 11:46AM TUKWILA DCD /PW P.4 /7 1 r„ • . � I .� , a jh j' I I :• 7K " '. • .•k - u ~Pal s 11" 1 1 � y � • ; jn ' r .� l n � ; • , I I • n I, `f K Or' . c:'l4� y, :����� I�rt �'►itI:II .I1 !'ylr �` u � ii `t•�I tIt',�i�•,� `VlWI r,l ' ;lf�gfl rl r � ,a� •KG! i�lr.. . � +u. . 1, 4;‘,;,',01 a , ira l�,1 ° rtl.T•: �i E.i}la �..i I!.•,. r��: r•1.; .,�.tf• " I tit� A 1 , •b�11h I1„! r s�at ;�: t+; • I �i 1 lr:;h�,t r ;(3 � 1 vt lt i �,r!h�a �11. all 1,1ul 1• ,.1 1� „ n , t ,I;;t 3iu Scope of Work (please provide detailed information):- kJ c5t 16.42fa. Call before you Dig: 1- 800 -424 -5555 '1?!leasel Kxo:Pi jiieiWor�cy;��ill�t�n,# ;Yoir:r �� �i ti�ite;s ►sec: �,;..:. ,'cr' ., Water District ❑ ...Tukwila ❑..,'Water District N 125 ❑ ...Water Availability Provided ❑ .. Highline ❑ ...Renton Sewer District ❑ ...Tukwila ❑... ValVue ❑ .. Renton ❑ ...Seattle ❑ ...Sewer Use Certificate ❑...Sewer Availability provided ❑ .. Approved Septic Plans Provided ❑ ...Septic Systcm - For onsitc septic system, provide 2 copies of a current septic design approval by King County Health Department. Submitted with Application (taark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22” x 34 ") ❑...Technical information Report (Stonn Drainage) ❑ ...Bond ❑ .. Insurance ❑ .. Eascmcnt(s) Proposed Activities (mark boxes that apply): ❑ ...Right -of -way Use - Nonprofit for Less than 72 hours ❑...Right -of -way Usc- No Disturbance • ❑ ...Construct ion /Excavction/FiI1 - Right -of -way Non Right -of -way ❑ ...Total Cut ❑ ...Total Fill cubic yards cubic yards ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities ❑...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ .. Geotechnical Report ❑...Traffic Impact Analysis ❑ .. Maintenance Agreement(s) ❑...Hold Harmless ❑ .. Right -of -way Use - Profit for Tess than 72 hours ❑ .. Right -of -way Use — Potential Disturbance ❑ .. Work in Flood Zonc ❑ .. Storm Drainage ❑ .. Abandon Septic Tank ❑ .. Curb Cut ❑ .. Pavement Cut .. Looped Fire Line ❑...Permanent Water Meter Sizc... ❑ ...Temporary Water Meter Size.. ❑ ... Watcr Only Meter Size ❑ ...Sewer Main Extension Public ❑ ...Water Main Extension Public lr )r I II 1r WON WON WOii Private Private ❑ .. Grease Interceptor .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undcrgrounding ❑ ,..Deduct Water Meter Size FINANCE INFORMATION Fire Line Sizc at Property Line ❑ ...Water ❑ ...Sewer Monthly Service Billing. to Name: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address; Number of Public Fire Hydrant(s) 0 ...Sewage Treatment Day Telephone: Cary State Zip Day Telephone: Stoic Zip 4pplic uonx \penny nppllem∎on (3.2003) V2003 Page 3 J MAR 30 '04 11:47AM TUKWILA DCD /PW .�ter u tli�` ',l:rl I ai ,k XI' I: P.5 /7 MECHANICAL CONTRACTOR INFORMATION Company Name: oT Mailing Address: A s Contact Person: E -Mail Address: Contractor Registration Number: City Day Telephone: Slue Zip Fax Number: Expiration Date: **An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): Use: Residential: New .... ❑ Replacement .... 0 Commercial: New ,.. • [] Replacement .... Fuel Type: Electric D Gas ....❑ Other: Indicate type of mechanical work being installed and the quantity below: ; Qinic•.T:yp°e :• • ,; _. ' ;:.., AP/. liTe y a : :,:,;,;,1 ; ':1::: :.',!:: ;.Qty: ' ; iU►- iiE :Eyp iv:" :•:.:':!'" ' •QtY.,., � e X Carii pr i ssar =::. : :;;ety,.. Furnace <l00K BTU Air Handling Unit >= 10,000 CFM Other Mechanical Equipment 0 -3 HP/ 100,000 BTU Furnace >100K BTU Evaporator Cooler 3 -15 1'IP /500,000 BTU Floor Furnace Ventilation Fan 15 -30 HP /1,000,00(1BTU Suspended /WaWFloor Mounted Heater Ventilation System 30 -50 HP /1.750,000 BTU Appliance Vent Hood 50+ HP /1.750.000 BTU Heat/Rcfrig /Cooling System Incinerator - Domestic Air Handling Unit <= 10,000 CFM Incinerator — Comm /Ind . -•-� t I i, t,. •a • iat • I °� I �� , r ,r 'i • ,w ,, OA l ' I P ; , I i l,•, ,!, ` 11 ffF..{L}}Ja �ik 1 a 9 I t u;,t r • 1, II!..1 I'J I•I n (,,•, ' ti , I J U r , v "'1 "1 ..4. . t1k ". ,..r nu • • . I 4i 411' . t iT r . i' r,. tt l Ot v ; . N .` 1 "r, t,lv., 1l 41 tt ' Il I I,�, Ab .'.. h�. t ; ,{r, }n., ! of 1 r. it q.if,.11i P1yn ti.I ,l{♦�a:1'ti'� UI �+ .t. Y,��y��l', .:,{'��6.� � �'.,tr (I �t}�.,.p.,t ddti.5`vlll•r�ulr p � p • �)�.y..,l � �F:. yy}..�!f' ,Y l,` � �Il Ir� 1 r � ■ .'.Il it "'Id1�3 'd .1 i1:1`'�� d w.L.. l,l�, /.,, }t..1 « .6.,, 1WW' 1, tihlii r r , °Fl ., : k' dui l »a' iu► ,)l ` ,,r ,I ,tl ' 1 11 . , 1 L I k'•�! I1 { Lj, '�,; 4 i i� ,,;{. � '0(00101, �{ , `t it i (r1 I r1<� {- 11'61 1 111•,.. �.. �.. �il.�ie��l')tlltlCr!.1;1;�(trt. i<;i'l r lif,l1'l,{'�f� t` '414.1 „r`l , N' l` r• t •r p r.,r, w, r ` °11 FIF,, �.I I)� N;; l �;;lhJ fr , �• ;1� I' �;: 1 1 , p „ttd•};1l�r 1, I`1 �,l �: ll..n'drt,,l ,l �I } Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fcc schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall cxpirc by Iitnitation. --The Building Official may extend thc time for action by the applicant for a period not exceeding 180 days upon written request by thc applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. I HEREBY CERTIFY THAT J HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERIU1tY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING _ R OR AUTHO ZED AGENT. Signature: ' / �1G�� darfljT Date: �� 1, ZOO'?" Print Name: Mailing Address: Day Telephone: rjQGj. 535' (08 city Stetc Zip Date Application Accepted: 1Ippltuticnttpcnn,t pollution (3.2003) 1 /1003 .,• Date Application Expires: ,QrZI:Iw9 Page 4 Staff Initials: Sys City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 RECEIPT Parcel No.: 2954900455 Permit Number: D04 -114 Address: 6720 FORT DENT WY TUKW Status: PENDING Suite No: Applied Date: 04/06/2004 Applicant: MONEYTREE, INC. Issue Date: Receipt No.: R04 -00404 Payment Amount: 108.71 Initials: SKS Payment Date: 04/06/2004 11:46 AM User ID: 1165 Balance: $171.75 Payee: BAKER CONSTRUCTION TRANSACTION LIST: Type Method Description Amount Payment Check 0408200 108.71 ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000/345.830 108.71 Total: 108.71 ;;. 04 '06 9 ?.1.4 TOTAL : of.3 n 71 doc: Receipt Printed: 04 -06 -2004 :3,1 '3 k'3L344 4.;.:,.+Yi.3.34if4 u4b.+A City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 z RECEIPT ' ;41 Z. ce w Parcel No.: 2954900455 Permit Number: D04 -114 6 o Address: 6720 FORT DENT WY TUKW Status: APPROVED co 0 Suite No: Applied Date: 04/06/2004 N w Applicant: MONEYTREE, INC. Issue Date: w H co� w 0 Receipt No.: R04 -00539 Payment Amount: 171.75 u. Y ? Initials: SKS Payment Date: 05/05/2004 02:16 PM H LLI User ID: 1165 Balance: $0.00 ' z I- I- O zI- w ui D o U O - • 0 I- ww =0 Payee: BAKER CONSTRUCTION TRANSACTION LIST: Type Method Description Amount O Payment Check 420640 171.75 Ow "; x OI,-. ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES 000/322.100 STATE BUILDING SURCHARGE 000/386.904 167.25 4.50 Total: 171.75 • 0614 05/06 9 716 TOTAL :4.71. • 75 doc: Receipt ♦.a u.�..,vi.n w,...w..n.9:4.w.. .... ✓�f.41:u.1 .u....n Printed: 05 -06 -2004 z INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Pro'ect:D O e . -4rU , U Type of Ins -- v () �'h A dress: 1 Dat Called:✓�'N��rr 7 �I� (72O b .W7 S ecial Instructions: p (-2- Date Wanted: 30 �L p.m. Requester: Phone No: Approved per applicable codes. ['Corrections required prior to approval. COMMENTS: p tt W1 i C l') In/1 14-e -e r Inspector: e----r Date: `7-30 -UPI El $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Cali to schedule reinspection. Receipt No.: Date: J• INSPECTION NO. CITY OF.TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit Project:, ,��' ,f' 9x . dam. Type of Inspe�n: /7 �.�= ,/r''�,1 Address: r 72a /- zY 7'Wy Date Called: - - , %-& // --- Special Instructions: �G l 1\Y . j / ��� A4 `1 Date Wanted: �j 7 G 1 '' (7 a.m. p.m. Requester: ,- Phone) 4/7.-- 2e,32 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: Ins Date: Z ve— d - f 474 REINSPECTION EE REQUIRED or to inspection, fee must be p• id at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: • Z W re 00 too W= JIB. U)u_ w0 2 J u- ?. a =W ZO W W 0 N • OH W W. o WZ v__ 0 "- 4 'I,. • City of Tukwila Steven M. Mullet, Mayor Fire Department Thomas R Keefe, Fire Chief TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM • Proj eat Name /14 -111 C Address 7 r, Permit No. 06)41-1/47/ Retain current.inspection_schedule Needs shift inspection V( Approved without correction notice Suite #27.3.10 Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre-Fire: Permits: Authorized Signahure FINALAPP.FRM Rev. 2/19/98 Date T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206-575-4404 • Fax: 206-575•4439 •■• • • • BAKER CONSTRUCTION & DEVELOPMENT, INC. Established 1951 To: City of Tukwila Department of Community Development Permit Center From: Joe Stoy • Baker. Construction E. 2711 Sprague Spokane, WA. 99202 Date: April 1, 2004 Dear Sirs, This narrative is for the demolition of an existing suite located at the Fort Dent Office Building. Suite 140. We propose to demolish the entire interior of the suite. We will repair all existing demising walls to provide a clean and ready space for a new remodel project for Moneytree Inc., which is also located in the building on the second floor. The reasoning for the demolition permit not tied together with the remodel permit is to investigate and identify any unknown conditions which may alter the final design of the new,space configuration and design. Sincerely Joseph E. Stoy Design Manager 2711 E, Sprague Avenue • Spokane, WA 99202 509.535.3668 • fax 509.5353720 • e -mail Baker271 I @aol.com Cont. Lk. 111HAKIiRCI)O66CZ G E N E R A L C O N T R A C T O R S C//.y,o „i Fa 4PR 7.-41124 2004 Ad00 01:1000 111A183d PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D04 -114 PROJECT NAME: MONEYTREE, INC. DATE: 04 -06 -04 SITE ADDRESS: 6720 FORT DENT WY, STE 140 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after/before permit is issued DEPARTMENTS: Building' Division J Public Works /1. k 592 AwG 443-of' Fire Prevention [el eA2 XIA- +-61)14 Planning Division Structural ❑ Permit Coordinator if DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 04 -08 -04 Complete [d Incomplete ❑ Comments: Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route [� Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 05 -06 -04 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.cloc 2-28-02 14'.1,.•nt... ta1`41.4sfmSGka PERMIT COORD COPY 'tS • x11.1:1.460luA:is .::..s'..arerc &•. wn :.tv..ew'.w F625- 052 -000 (8197) SYMBOLS LEGEND 12051 ROOM NUMBER REFERENCE DOOR TYPE /HARDWARE CONVENT ION: ROOM NUMRER DOOR TYPE HARDWARE TYPE 112051 EA b' IA -8.3 ELEVATION POINT DETAIL REFERENCE BUBBLE WALL SECTION REFERENCE BUBBLE /2\ REVISION REFERENCE a a c,.. INTERIOR aEVATION SYMBOL 24 REFERENCE KEY (REFER TO KEY NOTES) BREAK LINE SYMBOL WALL FINISH REFERENCE KEY (REFER TO FINISH SCHEDULE) FLOOR FINISH REFERENCE KEY (REFER TO FINISH SCHEDULE) f FT 3J - - - - - -- - -9 F.E.C. BASE REFERENCE KEY (REFER TO FINISH SCHEDULE) NORTH REFERENCE B/S SEMI - RECESSED WALL MOUNTED FIRE EXTINGUISHER CARDREADER LOCATION (COOR. WITH ELECTRICAL DWGS.) VICINITY MAP SCALE: NTS SEPARATE PERMIT REQUIRED FOR: MECHANICAL ELECTRICAL ji PLUMBING (e GAS PIPING CITY OF TUKWILA BUILDING DIVISION . ea' WOE '1`O Ilia SCOPE OF v. iNITSOUT PROIA trTSONIAL OF l'UPIA" :erg 143Te IeVIVC40 WO, 10111/10 SO #011. AO wog sow. arfigalln, WOW WS 1 LEGAL DESCRIPTION PARCEL R: THAT PORTION OF VACATED TRACTS 4 THROUGH 9 AND 12 THROUGH 17, AND VACATED STREETS ADJOINING IN GUNDAKER AND INTERURBAN ADDITION, LYING WITHIN SECTIONS 23 AND 24, TOWNSHIP 23 NORTH, RANGE 4 EAST W.M. DESCRIBED AS FOLLOWS: BEGINNING AT HIGHWAY ENGINEER'S STATION P.O.T. (2M) 127 +45.0 ON THE 2M LINE SHOWN ON THE STATE HIGHWAY MAP OF PRIMARY STATE HIGHWAY #1 (SR405) GREEN RIVER INTERCHANGE, SHEET 2 OF 4 SHEETS, ESTABLISHED BY COMMISION RESOLUTION #1192, FEBRUARY 19, 1962, THENCE NORTHEASTERLY AT RIGHT ANGLES TO SAID 2M LINE NORTH 30'27'06" EAST 218.36 FEET TO A POINT ON A LINE THAT IS PARALLEL WITH AND 140 FEET (MEASURED AT RIGHT ANGLES) NORTHEASTERLY OF THE SOUTHWESTERLY MARGIN OF VACATED KENNEDY STREET (6TH PLACE S.) AS SHOWN ON THE PLAT OF GUNDAKER'S INTERURBAN ADDITION TO SEATTLE, AS PER PLAT RECORDED IN VOLUME 14 OF PLATS, PAGE 46, RECORDS OF KING COUNTY, SAID POINT BEING THE TRUE POINT OF BEGINNING OF THE PARCEL TO BE DESCRIBED HEREIN, THENCE FROM SAID TRUE POINT OF BEGINNING ALONG SAID PARALLEL LINE NORTH 59'32'54" WEST TO THE BANK OF THE GREEN RIVER, THENCE ALONG THE BANK OF THE GREEN RIVER THE FOLLOWING COURSES: NORTH 38'19'12" EAST TO A POINT LYING SOUTH 30'04'58" WEST 334.53 FEET FROM THE SOUTHWESTERLY LINE OF THE LANDS CONVEYED 10 KING COUNTY BY STATUTORY WARRANTY DEED RECORDED UNDER RECORDING NO. 7507300471 AND NORTH 30'04'58" EAST 334 53 FEET TO SAID SOUTHWESTERLY LINE, THENCE ALONG SAID SOUTHWESTERLY LINE SOU1H 59'24'45" EAST 183.62 FEET TO A POINT ON THE NORTHWESTERLY LINE OF THE LANDS CONVEYED TO THE CITY OF 1UKWILA BY QUIT CLAIM DEED RECORDED UNDER RECORDING NO. 7410290105, THENCE ALONG LAST SAID NORTHWESTERLY LINE THE FOLLOWING COURSES: 'FROM A TANGENT THAT BEARS SOUTH 30'53'45" WEST ALONG THE ARC OF A CURVE TO THE LEFT HAVING A RADIUS OF 60.00 FEET AND A CENTRAL ANGLE OF 24'24'42 ", AN ARC LENGTH OF 13.63 FEET, THENCE TANGENT TO THE PRECEDING CURVE SOUTH 22'08'00" WEST 223.43 FEET, THENCE TANGENT TO THE PRECEDING CURVE SOUTH 30'27'06" WEST 66.52 FEET TO THE TRUE POINT OF BEGINNING, EXCEPT THAT PORTION CONVEYED TO THE CITY OF TUKWILA BY DEED RECORDED UNDER RECORDING NO. 7108040599, SITUATE IN THE CITY OF TUKWILA, COUNTY OF KING, STATE OF WASHINGTON. APN #295490 -0455 ABBREVIATIONS or O A/C ACOUS. AC. T. ADD. ADJ. ADJUS. A.F.F. ALT. APPROX. ARCH. 8D. BET. BLDG. BLK. BLKG. BOT. B/S CAB. CER. CHAMF. CIRC. CLG. CLR. CNTR. COL. CONC . CONST. CONT. AT CENTERLINE NUMBER SQUARE FEET DEGREE(S) AIR CONDITIONING ACOUSTICAL ACOUSTIC TILE ADDENDUM ADJACENT ADJUSTABLE ABOVE FINISH FLOOR ALTERNATE APPROXIMA TE ARCHITECT BOARD BETWFEN BUILDING BLOCK BLOCKING BOTTOM BUILDING STANDARD CABINET CERAMIC CHAMFER CIRCLE CEILING CLEARANCE) COUNTER COLUMN CONCRETE CONSTRUCTION CON T INUOUS CONTR. CONTRACTOR CORR. CORRIDOR CPT. CARPET C.T. CERAMIC TILE CTR. CEN TER DEMO. DET. D.F. DIAM. DIM. DN. DR. DWG. DWR. E. EA. EL. ELEC. ELEV. ENCL. EQ. EQUIP. EST. EXH. EXIST. EXP. EXT. F.E. F.E.C. DEMOLITION DETAIL DRINKING FOUNTAIN DIAMETER DIME NSION DOWN DOOR DRAWING DRAWER EAST EACH ELEVATION ELECTRICAL EL EVATOR ENCLOSE(URE) EQUAL EQUIPMENT ES1IMA1 E EXHAUST EXISTING EXPANSION EXTERIOR FIRE EXTINGUISHER EIRE EXTINGUISHER CABINET F. F. F.H. FIN. FLR. FLUOR F.O.S. F.O.C. F.O.F. FT. FURR. FUT. GA. G.B. G.C. GEN. GL. G.W.B. GYP. H.C. HD. HDCP. HDR. HDWR. H.M. HORIZ. HR. HT. H.V.A.C. FACTORY FINISH FULL HEIGHT FINISH(ED) FLOOR FLUORESCENT FACE OF S1 UD(S) FACE OF CONCRETE FACE OF FINISH FOOT /FEET FURRED /FURRING FUTURE GAUGE GRAB BAR GENERAL. CONTRACTOR GENERAL GLASS /GLAZING GYPSUM WALL BOARD GYPSUM HOLLOW CORE HEAD HANDICAPPED HEAUER HARDWARE HOLLOW ME TAI. HORIZON TAL HOUR HEIGHT HEATING VENTILATING AIR CONDITIONING INSUL. INSULATION INT. INTERIOR JAN. JANITOR JT. JOIN T KIT. KITCHEN KPL. KICKPLATE LAM. LAMINATE(D) LAV. LAVITORY L.H. LEFT HAND L. LENGTH /LONG L.L. O BY LANDLORD AT T.E. 1LNANT'S EXPENSE LT. LVR. MAX. M.C. MECH. MEMB. MET. MEZZ. MFR. MIN. MISC. MTD. MULL. N. N.F.S. N.I.C. NO. NOM. N.T.S. LIGHT LOUVER MAXIMUM MEDICINE CABINET MECHANICAL MEMBRANE METAL ME ZZANINE MAN UFACTURE(R) MINIMUM MISCELLANEOUS MOUNTED MULLION NORTH NON FROST SUSCEPTIBLE NOT IN CON1 RAC T NUMRER NOMINAL NOT 10 SCALE 0.A. OVERALL O.C. ON CENTER 0.D. OUTSIDE DIAMETER OH. OVERHEAD OPP.H. OPPOSITE HAND OPNG. OPENING OPP. OPPOSITE P.B. PANIC BAR P. BD. PARTICLE BOARD P- LAM PLASTIC LAMINATE PLWD. PLYWOOD PNL. PANEL PR. PAIR PTN. PARTITION Q.T. QUARRY TILE RAD. R.B. R.D. R.T. REF. REFL. REFR. REG. REINF. REQ. R.H. . RM. R.O. S. S.C. S.C.D. SCH. SEAL. SH. SECT. RADIUS RESIUENT BASE ROOF DRAIN RESILIENT TILE REFERENCE REFLECTED REFRIGERATOR REGISTER REINFORCING REQUIRED REVISION RIGHT HAND ROOM ROUGH OPENING SOUTH SOLID CORE SEA ► COVE R DISPENSER SCHEDULE SEALANT SHELF SECTION SHT. SHEET SIM. SIMILAR S.L.M. SPECIAL LAMINATED EDGE SPEC. SPECIFICATION SQ. SQUARE S.STL. STAINLESS STEEL STD. STANDARD STL. STEEL ST OR. STORAGE STRUCT. STRUCTURAL SUSP. SUSPENDED T.B. TOWEL BAR T.C. TERRA COT 1A TEL. TELEPHONE TEMP. TEMPERED TERR. TE RRAJ. ZO THK. THICKNESS) THRESH. THRESHOLD TKBD. TACK BOARD T.V. TELEVISION TYP. TYPICAL UNFIN. UNFINISHED U.N.0. UNLESS NOTED OTHERWISE VCT VINYL COMP. TILE VEN. VENEER VERT. VERTICAL VEST. VESTIBULE VFY. VERIFY V.W.C. VINYL WALL COVERING w. WEST /WIDE W/ WITH WO. W000 WT WE T WE C,,NT WSCT. WAINSCOT GENERAL NOTES 1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SAFETY IN THE AREA OF WORK IN ACCORDANCE WI I H ALL APPLICABLE SAFE rY CODES. 2. THE CON TRACTOR SHALL INDEMNIFY AND I101.D THE BUILDING OWNER /ARCHITECT /ENGINEER HARMLESS FOR INJURY OR DEAIIT TO PERSONS OR FOR DAMAGE TO PROPERTY CAUSED BY THE NEGLIGENCE OF THE CONTRACTOR, HIS AGENTS, EMPLOYEES, OR SUBCONTRACTORS. 3. EACH CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE TO ADJACENT WORK AND SHALL REPAIR SAID DAMAGE AT HIS OWIJ EXPENSE. 4. SPRINKLER, PLUMBING, MECHANICAL, AND ELECTRICAL ARE UNDER SEPARATE PERMIT. 5. CODES: ALL WORK SHALL CONFORM TO THE APPLICABLE BUILDING CODES AND ORDINANCES. IN CASE OF AN 7' CONFLICT WHERE THE METHODS OR STANDARDS OF INSTALLATION OF THE MAIERIAI.S SPECIFIED DO NOT EQUAL OR EXCEED THE REQUIREMENTS OF THE LAWS OR ORDINANCES, THE LAWS OR ORDINANCES SHALL GOVERN. NOTIFY THE ARCHITECT OF ALL CONFLIC TS. 6. STRUCTURAL, PLUMBING, MECHANICAL, ELECTRICAL AND FIRE PROTECTION DRAWINGS ARE SUPPLEMENTARY TO THESE DRAWINGS. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ALL DISCREPANCIES BETWEEN THE CONSULTANTS' DRAWINGS WITH A WRITTEN REQUEST FOR CLARIFICATION. ANY WORK INSTALLED IN CONFLICT WITH 1HESE DRAWINGS OR SPECIFICATIONS SIIAI L BE CORRECTED BY THE CONTRACTOR AT NO EXPENSE 10 THE BUILDING OWNER, TENANT, OR ARCHITECT. 7. USE G.W.B. METAL TRIM AT ALL CORNERS AND EDGES, PAINT TO MATCH ADJACENT WALL. 8. AT COMPLETION OF THE WORK, REMOVE ALL DEBRIS FROM THE SITE, LEAVING SPACE CLEAN, WASH ALL WINDOWS AND GLASS, POLISH ALL HARDWARE. REPLACE AND PATCH AREAS OF CEILING DAMAGED DUE TO LIGHTING INSTALLATION OR MECHANICAL ADJUSTMENT. 9. CONTRACTOR IS RESPONSIBLE FOR ALL NECESSARY PERMITS & FEES, EXCEPT THE BUILDING PERMIT SUBMITTAL FEE WHICH WILL BE PROVIDED BY THE TENANT. DIMENSIONS 1. ALL INFORMATION SHOWN ON THE DRAWINGS RELATIVE TO EXISTING CONDITIONS IS GIVEN AS THE BEST PRESENT KNOWLEDGE BUT WITHOUT GUARANTEE OF ACCURACY. THE CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS AND DIMENSIONS AND SHALL NOTIFY THE ARCHITECT OF ANY DISCREPANCIES OR CONDITIONS ADVERSELY AFFECTING THE DESIGN PRIOR TO PROCEEDING WITH THE WORK. 2. DO NOT SCALE DRAWINGS: THE CONTRACTOR SHALL USE DIMENSIONS SHOWN ON THE DRAWINGS AND ACTUAL FIELD MEASUREMENTS. NOTIFY THE ARCHITECT IF DISCREPANCIES ARE FOUND. 3. COORDINATION: THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE VERIFICATION AND COORDINATION OF THE WORK OF ALL TRADES TO ASSURE COMPLIANCE WITH THE DRAWINGS. 4. CONSTRUCT WALLS PLUMB AND SQUARE W/ EXISTING STRUCTURE AND NEW CONSTRUCTION UNLESS NOTED OTHERWISE. FIRE PROTECTION 1. IF NECESSARY, PROVIDE FIRE PROTECTION AT ALL PENETRATIONS OF FIRE RATED ELEMENTS AS REQUIRED BY CODE. CONSTRUCTION 1. COORDINATE CONSTRUCTION SCHEDULING WITH BUILDING REPRESENTATIVE AND ARCHITECT TO ALLOW ONGOING OPERATION OF THE FACILITY DURING CONSTRUCTION. 2. CONTRACTOR SHALL INVESTIGATE AND VERIFY LOCATIONS OF STRUCTURAL, PLUMBING, MECHANICAL, AND ELECTRICAL ELEMENTS AND OTHER EXISTING CONDITIONS PRIOR TO BEGINNING THE WORK. 3. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING FIRE TREATED BLOCKING REQUIRED FOR WALL AND CEILING MOUNTED ITEMS. 4. ALL NEW CONSTRUCTION SHALL BE STABILIZED AGAINST LATERAL MOVEMENT IN ACCORDANCE WITH THE REQUIREMENTS OF THE LATEST ADOPTED EDITION OF THE UNIFORM BUILDING CODE. MAX. DISTANCE ACCEPTABLE BRACES SHALL BE 8' -0 ". 5. THERE SHALL BE NO EXPOSED PIPE, CONDUITS, DUCTS, VENTS, ETC. ALL SUCH LINES SHALL BE CONCEALED OR FURRED AND FINISHED, UNLESS NOTED AS EXPOSED ON CONSTRUCTION DRAWINGS. 6. OFFSET STUDS WHERE REQUIRED SO THAT FINISH WALL SURFACES WILL BE FLUSH. CEILING 1. CEILING HEIGHTS, WHERE INDICATED, ARE FROM FINISHED FLOOR ELEVATION TO BOTTOM OF CEILING GRID OR OTHER FINISH SURFACE. 2. SUPPORT DATA - LATERAL SUPPORT SHALL BE PROVIDED BY FOUR WIRES OF MIN. 12 U.S. GAUGE SPLAYED IN FOUR DIRECTIONS, 90 DEG. APART AND CONNECTED TO THE MAIN RUNNER WITHIN 2" OF THE CROSS RUNNER AND TO THE STRUCTURE ABOVE AT AN ANGLE NOT EXCEEDING 45 DEG. FROM THE PLANE OF THE CEILING. THESE LATERAL SUPPORTS SHALL BE PLACED 12' -0" O.C. IN EACH DIRECTION, WITH THE FIRST POINT WI THIN 4' -0" FROM EACH WALL. SEE DETAIL 12/IA -9.1. 3. VERTICAL SUPPORTS SHALL BE NO. 8 U.S. GAUGE WIRE TO SUPPORT A MAX. 16 SQ. FT. OF CEILING AND SADDLE -TIED AROUND MAIN RUNNERS, PER CHAPTER 47.1812 OF THE UBC STANDARDS. CROSS RUNNERS AT1ACHED TO MAIN RUNNERS BY SADDLE -TYING WITH ONE STRAND NO. 16 U.S. GAUGE TIE WIRE, OR APPROVED EQUIVALENT, PER CHAPTER 47.1812 OF THE UBC STANDARDS. DISCONTINUOUS ENDS OF CROSS- RUNNERS AND MAIN RUNNERS TO BE VERTICALLY SUPPORTED WITHIN 8" OF SUCH DISCONTINUITIES AS MAY OCCUR WHERE CEILING IS INTERRUPTED BY A WALL. 4. CONTRACTOR SHALL INSTALL CEILING TILES ONLY AFTER ALL CABLING AND CEILING PLENUM EQUIPMENT /DUCTWORK HAS BEEN INSTALLED. FINISHES 1. ALL PAINT AND OTHER APPLIED FINISH ITEMS SHALL BE APPLIED IN ACCORDANCE WITH THE MANUFACT URER'S RECOMMENDATIONS. 2. CARPET CONTRACTOR SHALL FURNISH AND INSTALL RUBBER REDUCER STRIPS AT LOCATIONS WHERE CARPET AND VINYL COMPOSITION TILES MEET. 3. FLOOR COVERING IN CLOSETS SHALL BE THE SAME AS THAT OF THE SPACE UNTO WHICH THE CLOSET DOOR OPENS, U.N.O. 4. PREPARE FLOOR PER FLOORING AND CARPET MANUFACTURER'S RECOMMENDATIONS TO PROVIDE LEVEL AREA FOR FLOORING INSTALLATION AND LEVEL FLOORING TRANSITIONS. 5. CONTRACTOR TO SUBMI t FULL CARPET SEAMING PLAN AND INSTALLATION METHOD TO ARCHITECT FOR APPROVAL PRIOR TO INSTALLATION. PLUMBING,MECHANICAL & ELECTRICAL 1. PLUMBING, MECHANICAL, & ELECTRICAL DRAWINGS TO BE SUBMITTED UNDER SEPARATE PERMIT. DRAWING INDEX - 0.0 IA- 1.1 IA -2.1 GENERAL NOTES SITE PLAN DEMOLITION AND PROPOSED FLOOR PLAN FILE COPY I understand that the Plan Check approvals are subject to errors and omissions and approval of plans does not authorize the violation of any adopted code or ordinance. Receipt of con- tractor's copy of approved plans acknowledged. By h./. Date 5 / r.of , Permit No. • CODE INFORMATION CONSTRUCTION TYPE: 5 -N OCCUPANCY: B BUILDING IS SPRINKLERED APPLICABLE EDITIONS OF BUILDING CODES: REG. FOR BARRIER FREE DESIGN. 1997 UNIFORM BUILDING CODE 4th EDITION OF THE WASHINGTON STATE AREA: BUILDING AREA: 39,274 SF TENANT IMPROVEMENT: 1,752 SF PROJECT TEAM OWNER J.C. RADOVICH 2000 124TH AVE. NE., 13103 BELLEVUE, WA 98005 VOICE: (425) 454 -6060 -FAX: (425) 453 -9740 CONTACT PERSON: REBECCA DAVIDSON c-T BUILDING TENANT MONEYTREE, INC. 6720 FORT DENT WAY, #2.30 SEATTLE, WA 98188 CONTACT: MEAGAN HENDERSON VOICE: (206) 246-3500 EMAIL: Meagan .Henderson @Moneytreeinc.com ARCHITECT JPC ARCHITECTS 355 110TH AVE NE SUITE 100 BELLEVUE, WA 98005 VOICE: 425 --641 -9200 FAX 425 -637 -8200 CONTACT PERSONS: Mork Peterson /Jennifer EMAIL: Markp @jpcarchitects.corn GENERAL CONTRACTOR BAKER CONSTRUCTION 2711 E. SPAGUE AVENUE SPOKANE, WA 99202 VOICE: 509-535-3668 FAX 509 - 535 -3720 CONTACT PERSON: JOE STOY ELECTRICAL CONTRACTOR TBD. Mu MECHANICAL CONTRACTOR TBD. • • • d � I JPC ARCHITECTS 355 110th Ave NE- ,Su'te 100 Bellevue, WA 98004 tel 14251641 -9200. fax (4251637 -8200 MONEYTREE 6720 FORT DENT WAY #140 FORT DENT . - OFFICE BUILDING TUKWILA, WASHINGTON Design Team FPC Pro d No JPC UL.JI.' 03 -24 04 04 -- 1. P0 -014) Revisions No pole Descr+pia, 30/04 _ lit ":_.)LIi f ERMIT Registration Keyplan Sheet Title GENERAL NOTES RECEIVED OrTY OF TUKWILA APR - 6 2004 PERMIT CENTER Sheet No IA-O.O Ardiscet. RlC .. .,.- .1 1 Amp WNW OWNS Wawa all'ift.**1.18"ipasiiia.......wWww/•••■••••••••••• 0.10•15 Mewl Arliorrberi.14.01, 01■101MONMINIIMINI PARKING 1 11%.11.0■••••■••••••••••••••■••■re0...................11111•111M■VJ all•O raWIN WWWWWWw/Wwwwwwwww 1, NIS 0 334.551 0/000 IIIRMOMENs...MN/IINNIND diall■ 0.1■16 NO.WIN mime ow.. .........ww••••••••• sirs ammo a....w••••wxwwwwnw• woo. Mae SCOPE OF WORK -FIRST FLOOR: 1,752 SOFT -NO STRUCTUAL CHANGES allOPOIMINMOMMINNIMOIMI 0.111101 alMINOMMOSOMMIIIIN. 40 COURTYARD SITE PLAN Scale: 1/20N_1 II rac pe41. WAY 0.11.11 OM. 111.111111••••••••••■•••••■ arm • FAKING 1 1 1 1 1 48, • a JPC ARCHITECTS ■ 355 110th Ave NE- Suits 100 Bellevue, WA 98004 tel 14251641-9200. fax 4251637-8200 M ON EYTREE 6720 FORT DENT WAY #140 FORT DENT . OFFICE BUILDING. TUKWILA, WASHINGTON Design Team JPC Drown -ttawckwd 'bob -JPC Profs; No DL,JM 03-24-04 04 100-014° Revisions No Doscriplico ■••■■■■•■■■ 0.5 SO/0,1 [Afoul...010c PERkscr Registration Keyplan Sheet Title SITE PLAN RECEIVED 0/T' OF •UKWILA APR - 6 2004 PERMIT ENTER Sheet No • IA-1.1 _knot Plc MMus. PlIC r 4114. e• • 1 44•. 44•• • (lU I; 1 ;I 1! (J 1 SCOPE OF-- --\ WORK L If r? 1. • • • + tit sh 141.1%. 1, y6 1 • • • • • • • • • 0 r}) • • • • • • / r 1 1 LIMITED SCOPE OF WORK: THE SCOPE OF WORK FOR THIS SUBMITTAL 13 LIMITED ONLY TO THE DEMOLITION WORK OF THE EXISTING UNOCCUPIED TENANT SPACE AS NOTED IN THE DRAWING. AND THERE 18 NO STRUCTURE RELATE' WORK TO BE INVOLVED. DEMO PLAN - 1ST FLOOR Scale: 1/8"=1'-o" tJ O; SYMBOLS LEGEND R - RELOCATED D = DEMOLISHED N - NEW POWER OUTLET COMMUNICATIONS OUTLET ALL DASHED POWER OUTLETS & COMMUNICATION PORTS INDICATE DEMOLISHED POWER OUTLETS & COMMUNICATION PORTS. • 0 0 SCOPE OF --- -- WORK EXIST II OFF IC NEW OFFICE NEW OFF ICE BREAKROOM /COPY $11===1W- NEW OFF ICE NEW OF F" ICE y Lo STORAGE ELEC. NEW OFFICE NEW OFFICE FILE • • • • • • • 0 • • • 0 J o"' PROPOSED FLOOR PLAN - 1ST FLOOR Scale: 1/8 "= — " DEMO KEY NOTES ALL EXISTING FINISH FLOORING AND BASE TO BE DEMOLISHED. PATCH AND REPAIR AFFECTED SUBSTRATE AS REQUIRED FOR INSTALLATION OF NEW FINISH FLOORING AND BASE MATERIALS. REFER TO FLOOR AND FINISH PLAN FOR ADDITIONAL INFORMATION. DEMOLISH EXISTING PARTITION WALLS (PARTIAL, GRID HEIGHT & FULL HEIGHT) PROTECT EXISTING ADJACENT SURFACES, INCLUDING BUT NOT LIMITED TO CEILING, ADJACENT WALLS AND FLOORING. 0 REMOVE, SALVAGE AND REUTILIZE (WHERE PRACTICAL) EXISTING ELECTRICAL AND LOW VOLTAGE DEVICES. REFER TO GENERAL NOTES AND DESIGN -BUILT CONSULTANT DOCUMENTS FOR ADDITIONAL INFORMATION. 4 REMOVE AND SALVAGE EXISTIN( DOORS, FRAMES, SIDELITES AND HARDWARE FOR REUSE AND REINSTALLATION WHERE PRACTICAL. REFER TO FLOOR PLAN FOR ADDITIONAL INFORMATION. 5 DEMOLISH AND DISPOSE OF EXISTING NON - SALVAGEABLE MILLWORK /CABINETRY. REFER TO GENERAL NOTES FOR ADDITIONAL INFORMATION. V FLOOR KEY NOTES 0 FUTURE FLOOR PLAN BY SEPERAIE PERMIT SUBMITTAL. 1. DEMO NOTES COMPLY WITH ALL RULES AND REGULATIONS OF GOVERNMENTAL AUTHORITIES HAVING JURISDICTION OVER DEMOLITION WORK. 2. DEMOLITION INCLUDES COMPLETE REMOVAL AND DISPOSAL. OF DEMOLISHED ITEMS. RETAIN SALVAGEABLE ITEMS WHERE OR WHENEVER APPROPRIATE. COORDINATE STORAGE WITH OWNER OR REUSE ON PROJECT. 3. NOTIFY ARCHITECT IMMEDIATELY OF ANY CONFLICTS BE ; WEEN EXISTING CONDITIONS AND NEW CONSTRUCTION PRIOR TO PROCEEDING WITH THE WORK. 4. REMOVE, REPLACE AND RELOCATE EXISTING MECHANICAL, ELECTRICAL AND FIRE PROTECTION EQUIPMENT /DEVICES AS REQUIRED FOR NEW CONSTRUCTION. AT LOCATIONS WHERE ELECTRICAL IS TO BE REMOVED, PULL OUT WIRING BACK TO PANEL. SEE DESIGN BUILD MECHANICAL, ELECTRICAL AND COMMUNICATIONS DRAWINGS FOR ADDITIONAL INFORMATION. 5. PROTECT STRUCTURAL ELEMENTS FROM DAMAGE DURING CONSTRUCTION. 6. PRIOR TO START OF WORK, COORDINATE WITH TENANT THE SCHEDULE FOR SHUTOFF, CAPPING AND /OR CONTINUATION OF UTILITY SERVICES REQUIRED. 7. EXISTING DOORS, FRAMES AND HARDWARE SCHEDULED TO BE REMOVED SHALL BE SALVAGED AND RELOCATED TO OWNER STORAGE OR REUSE WHERE OR WHENEVER APPROPRIATE. 8. PATCH AND REPAIR EXISTING WALLS AT DEMOLISHED AREAS TO A "LIKE -NEW" APPEARANCE. J • ..- 355 110th Ave NE - ,Suite 100 Bellevue. WA 98004 teI 425J 641 -9200, fax 14251637 -8200 MONEYTREE 6720 FORT DENT WAY #140 FORT DENT OFFICE BUILDING TUKWILA, WASHINGTON Design Team JPC DL.J'.' MP -5PC Ponied No 03 -24 - 04 04 -11.10 -0149 Revisions _a• peocripeon U.S ,S2/04 OL.I,1 I_I LI f ION PE R t.t I T Registration Keyplan Sheet Title DEMOLITION & PROPOSED FLOOR PLAN, „m"an�Iu APR — 6 r": Sheet No A -2.1 2007. JPC Mdliira. Otte •