Loading...
HomeMy WebLinkAboutPermit D04-135 - FIRST CHOICE SERVICES - STORAGE RACKSFIRST CHOICE SERVICES 4471 SOUTH 134T" PLACE D04 -135 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 2613200084 Address: 4471 S 134 PL TUKW Suite No: DEVELOPMENT PERMIT Permit Number: D04 -135 Issue Date: 04/30/2004 Permit Expires On: 10/27/2004 Tenant: Name: FIRST CHOICE SERVICES Address: 4471 S 134 PL, TUKWILA WA Owner: Name: NORTH STREAM DEVELOPMENT Address: 720 4TH AV STE 102, KIRKLAND WA Contact Person: Name: MIKE SORENSON Address: 1100 SW 7 ST, RENTON, WA Contractor: Name: NORTH WEST HANDLING SYSTEMS INC Address: 1100 S.W. 7TH STEET, RENTON, WA Contractor License No: NORTHWH275JF Phone: Phone: 206 818 -4488 Phone: 206 255 -0500 Expiration Date:10 /09/2005 DESCRIPTION OF WORK: INSTALLING NEW PALLET RACKING FOR STORAGE OF CONSUMABLE OFFICE PRODUCTS. SIX BAYS 12' TALL; SEVENTEEN BAYS 16' TALL. Value of Construction: $ $0.00 Fees Collected: $141.86 Type of Fire Protection: SPRINKLERS Uniform Building Code Edition: 1997 Type of Construction: Occupancy per UBC: 0025 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: N Hauling: N Start Time: End Time: Land Altering: N Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: N Moving Oversize Load: N Start Time: End Time: Sanitary Side Sewer: N Sewer Main Extension: N Private: Storm Drainage: N Street Use: N Profit: N Water Main Extension: Water Meter: N N Private: Public: Non - Profit: N Public: doc: Devperm D04 -135 Printed: 04 -30 -2004 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Permit Center Authorized Signature:. Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit. Signature: Date: 1/71o4) L/ Print Name: le This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: Devperm D04 -135 Printed: 04 -30 -2004 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 15: High -piled combustible storage is combustible materials in closely packed piles more than 12 feet in height or combustible materials on pallets or in racks more than 12 feet in height. For certain special- hazard commodities such as rubber tires, plastics, some flammable liquids, idle pallets, etc., the critical pile height may be as low as 6 feet. (UFC article 2, sec. 209 -H) 16: Maintain minimum 6" longitudinal flue space between back to back racks. (NFPA 13) 17: Where storage height exceeds 15 feet and ceiling sprinklers only are installed, fire protection by one of the following methods is required for steel building columns,located within racks: (a) one -hour fire proofing, (b) sidewall sprinklers at the 15 foot elevation of the column, (c) ceiling sprinkler density minimums as determined by the Tukwila Fire Prevention Bureau. (NFPA 13) =z '~ w 6 +J 0 CO 11.1 LLI w0 Q 18: Depending on the classification of the commodity being stored and the size of the storage area, smoke vents, small hose to stations and curtain boards may be required by Table 81 -A of the Uniform Fire Code. Contact the Tukwila Fire Prevention ▪ w Bureau for further information. z ZO U.1 uj • 0 U N 20: Nominal 6" transverse flue spaces between loads and at rack uprights shall be maintained in single row, double row and 0 - multiple row racks. Random variations in the width of flue spaces or in their vertical alignment shall be permitted. w (NFPA 231c 4 -3.1) 0 21: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. v 0 19: Racks designed for high -piled storage must comply with section 2207 of the Uniform Building Code. Please contact the Tukwila Building Department for details pertaining to design and installation standards. 22: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 23: These plans were reviewed by Inspector 512. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Date: 11 /..?0 Print Name: /P17(... doc: Conditions D04 -135 Printed: 04 -30 -2004 z City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 2613200084 Address: 4471 S 134 PL TUKW Suite No: Tenant: FIRST CHOICE SERVICES PERMIT CONDITIONS Permit Number: D04 -135 Status: ISSUED Applied Date: 04/21/2004 Issue Date: 04/30/2004 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 3: All permits, inspection records, and approved plans shall be available at the job site prior to the start of any construction. These documents are to be maintained and available until final inspection approval is granted. 4: All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 5: Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. 6: ** *FIRE DEPARTMENT CONDITIONS * ** 7: The attached set of plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 8: Maintain fire extinguisher coverage throughout. 9: Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5) 10: Maintian sprinkler coverage per N.F.P.A. 13. Addition /relocation of walls, closets or partitions may require relocating and /or adding sprinkler heads. 11: Sprinkler protection shall be extended to all areas where required, including all enclosed areas, below obstructions and under overhangs greater than four feet wide. (NFPA 13- 4- 5.5.3.1) 12: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recorgnized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1901) 13: Contact the Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1900 and #1901) 14: In double row racks with heights of storage up to and including 25', an average nominal 6" transverse flue space between loads or at rack uprights shall be maintained. (NFPA 13) doc: Conditions D04 -135 a.. Printed: 04 -30 -2004 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 Building Permit Mechanical Permit Public Works Permit No. . For office use only 0. Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** Site Address: yZ 7 r / 31(6 L- - Tenant Name: i r.S 1 Ono fee Sit-v;G -e. s Property Owners Name: Mailing Address: King Co Assessor's Tax No.: c'2' / 2 '-'00#y Suite Number: � Floor: New Tenant: NO... Yes [] ..No Name:`/( -� �G f O.►�J CJ ✓1 Mailing Address: /MO Gy '" S- E-Mail Address: fl l5a P 2r 4i e0 /1 t-✓ k S . City State Day Telephone: ■O g/8 c4/ E GENERAL CONTRACTOR INFQRMATIQ Company Name: Y State Zip Fax Number: 111/0-15- at9S O / ?'/ Mailing Address: // 2 ...574./ 7041- S2: /let gre<4.5-6.1 E -Mail Address: !/YISO!'P.vl fur, M Fax Number: f mil, a a ‘9 V6 Contractor Registration Number: ,412, Ttfi/✓7-7/ "Expiration Date: fe.VD ��QS * *An original or notarized copy of current Washington State Contractor License must be presented a the time of permit issuance ** Contact Person: Ity/1 State Zip Day Telephone: �6 8 %cf ce- -ARCHITECT OF: RECORD :All plans must be Wet stamped.by Architect of Record , Company Name: Mailing Address: Contact Person: 2 E -Mail Address: City Day Telephone: Fax Number: State Zip ENGINEER OF RECORD. - All plans must be wet stamped by Engineer of Record Company Name: I ( de 729s/ it a Mailing Address: 3 7 Pe c eel City State Zip Day Telephone: 9.5-7 9t c E -Mail Address: Fax Number: O e e of S 7 c) Contact Person: G- eLr-i7 ht lapplicationskpermit application (1.2003) 1/2003 Page I n;:+wrtn.r,.s'+o.l H: ^i ;'L:»�:;,rr.)v�+r,6: X5(1 r^c'm'rn.w.n�.tn W;a7,'rMFy.r,•hxr nstC�'.f�fl. ^r;t <,rr+t «�.�« <.m;.ri.n.+r Mztf; �ti; •; /Y- ,.,cj..s /a:!H tlatOtt, .sVO,( ,`c',itP? Vt BUILDING PERMIT.;INFORMA ON = 206 = 43,1 -3670 • Valuation of Project (contractor's bid price): $ ?G ' ' Existing Building Valuation: $ r66 'f Scope of Work (please provide detailed information): .J SI 114, c2'7 AAA-Li < e'rV� a-E n, (c/ car( rode ch 5bA4. c// k Grgt off- , / sic e creel t//'t -f' Will there be new rack storage? ®...Yes 0 .. No 1 If "yes ", sec Handout No. for requirements. Provide All Building Areas in Square Footage Below Existing Interior Remodel Addition to Existing Structure New Type of Construction per UBC Type of Occupancy per UBC '1$1 Floor • • 2n0 Floor . 3r° Floor : • Floors ` ' thru • :Basement'. :,Accessory Structure* Attached: Garage Detached Garage Attached Carport • Detached Carport Covered Deck Uncovered. Deck 7`/4'1 yoo PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0...Yes l'Y.. No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: a.. Sprinklers ❑...Automatic Fire Alarm 0...None SE .. Other (specify) re. �'�% li hwfoiti Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 .. Yes *...No ✓ If "yes", attach list of materials and storage locations on a separate 8 -1/2 x 11 paper indicating quantities and Material Safety Data Sheets. UTILITY DISTRICTS: Note: If the utility district is not City of Tukwila, you must provide written verification and approval from that utility district at the time of permit application. W ter City of Tukwila Water District 0.. Water District i125 Sewer 0... Highline Water District o... City of Renton Water District .. City of Tukwila Sewer District 0.. Val Vue Sewer District ❑...City of Renton Sewer District ❑...City of Seattle Sewer District ❑ .. Septic System (If property is served by a septic system, 2 copies of approved septic design from King County Health Department must be submitted at the time of permit application) \appliations\permit application (1 -2003) 1/2003 Page 2 MECHANICAL CONTRACTOR INFORMATION Company Name: Mailing Address: Contact Person: E -Mail Address: Contractor Registration Number: * *An original or notarized copy of current Washington State Contractor nse must be presented at the time of permit issuance ** City Day Telephone: Fax Nu ate Zip 'ration Date: Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information) Use: Residential: ew ....0 Replacement .... Commerc' • . New .... 0 Replacement .... Fuel Type: lectric 0 Gas ....E] Other: ate type of mechanical work being installed and the quantity below: Unit Type: Qty Unit Type: Qty Unit Type :. Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >= 10,000 CFM Other Mechanical Equipment 0 -3 HP /100,000 BTU 3 -15 HP/500,000 BTU Furnace >100K BTU Evaporator Cooler Floor Furnace Ventilation Fan 15 -30 HP/I,000,000 BTU Suspended/Wall /Floor Mounted Heater Ventilation System 30 -50 HP /1,750,000 BTU Appliance Vent Hood 50+ HP /1,750,000 BTU Heat/Refrig/Cooling System Incinerator - Domestic Air Handling Unit <= 10,000 CFM Incinerator — Comm /Ind • PERMIT :APPLICATION -NOTES = Applicable to all permits in this application.; Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHO ZIZE a = T: Signature: Print Name: Mailing Address: // _571/ 743 57, Date Application Accepted: Date: Day Telephoner6 e g / ,6 77O City state Zip Date Application Expires: la --2-/ -6y Staff Initials: \applications \permit application (1 -2003) 1/2003 Page 4 City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 RECEIPT Parcel No.: 2613200084 Permit Number: D04 -135 Address: 4471 S 134 PL TUKW Status: APPROVED Suite No: Applied Date: 04/21/2004 Applicant: FIRST CHOICE SERVICES Issue Date: Receipt No.: R04 -00515 Payment Amount: 87.75 Initials: SKS Payment Date: 04/30/2004 03:19 PM User ID: 1165 Balance: $0.00 Payee: NORTHWEST HANDLING SYSTEMS TRANSACTION LIST: Type Method Description Amount Payment Check 195604 87.75 ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES STATE BUILDING SURCHARGE 000/322.100 83.25 000/386.904 4.50 doc: Receipt Total: 87.75 07332 05/04 1710 TOTAL. 87.75 Printed: 04 -30 -2004 City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Z RECEIPT ce w Parcel No.: 2613200084 Permit Number: D04 -135 6 v Address: 4471 S 134 PL TUKW Status: PENDING v 0 Suite No: Applied Date: 04/21/2004 co w Applicant: FIRST CHOICE SERVICES Issue Date: -I H U) LL. w 0 2 Receipt No.: R04 -00471 Payment Amount: 54.11 u., Q Initials: SKS Payment Date: 04/21/2004 11:23 AM i d w User ID: 1165 Balance: $87.75 , Z H I— 0 Z I— I/1 uj O 0 O -. O H w ui Type Method Description Amount F- 1 -0 Payment Cash 54.11 lj,i Z H • "- O I— Z Payee: MIKE SORENSON TRANSACTION LIST: ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000/345.830 54.11 Total: 54.11 ..0i5O 04/22 9716 TOTAL 54".1.1 doc: Receipt Punted: 04 -21 -2004 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION,,, 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit Pr ct: Type of Ins Von: Address : , 7 i ) 31 n Date Calle . LI 4-t . Spec al Instructior(: Date Wanted: j D p.m. Requester: Phone N0 - ID — Loci*, RApproved per applicable codes. COMMENTS: Inspector:(' Corrections required prior to approval. RPJ vvti4 C.nwt 0\4- \ V�G� Date: s_ UGI JJ $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit Pro a t: 1 Fr P51 C/(O( ..-- Typ of Inspection: T,{t.,S' -- P //t'4 -L. Address: 411/ 7 / 5 - /3Yii Date ailed: V'eACILS are thr'Or(f(4 -• ?Pr ! (�'l�fro it Special Instructions: Date Wanted: r Vr 0 (a.m., p.m• Requester: 1 -----._e(-6..( l Y \ rS`0fc�l %cam I,W 1v-P v Phon o: aApproved per applicable codes. Corrections required prior to approval. COMMENTS: I . { l.�OQ f t no i + � 1 ci o S - U`V —,/ �-P 1 I , V'eACILS are thr'Or(f(4 -• ?Pr ! (�'l�fro it S (AbyeA r71 9 \',.,M, c ^..t p so() () t S Y 1-P V-c. l 7.- c, (-e 1 r\ P4 t 541 v-r c1`(1^ S 1�} 1ah S141-t- 4 ' 5i-7 .e , v\ekt (al I V‘t,i c S7)Q ()9 s. 1 -----._e(-6..( l Y \ rS`0fc�l %cam I,W 1v-P v A) CA-e % 01 419 6 c 7 0 :, A I' ` t l sco c l�. 5 1A) ■ L ?10 ct u c i- Inspector:(. ) 4.4„...A Date: )-' oi, LJ $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection. Receipt No.: Date: Z A- Z cc W _1 0 O O too J H (o� 0 u_ a �w Z= Z O W 0 O N 1I I•- WW H � 11 0 WZ U= O~ Z . r..;:.:•N-77■7.717-0""9" '07." ,17‘., .; , Zfri;:rkl,9%71{,77..7),:zry„,, ; 4 • ‘, , TT .-^",%74.,. G.- • . City of Tukwila Fire Department 9' TUKWILA FIRE DEPARTMENT .FINAL APPROVAL FORM ...project.Name (../-Le.);116- Address e / e„. 77 / Needs shift inspection Steven M Mullet, Mayor Thomas 1? Keefe, Fire Chief Permit No. Suite # Approved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre-Fire: Permits: Authorized Signature FINALAPP.FRM (..r- t /-4„," /91A/ Rev. 2/19/98 Date T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206-575-4404 • Fax: 206-575-4439 ...........v.aktztteer‘fX4147443 1 by G. OHANIAN DATE 4 -17 -04 SUBJECT. RtiJK DESIGN & ENGINEERII\ CO. 3786 LA CRESCENTA AVE., SUITE 204 GLENDALE, CA. 91208 TEL:(818)957 -2980 FAX:(818)957 -8603 SHEET NO 1 JOB NO. RD -8724 1 FILE COPY STRUCTURAL CALCULATIONS OF STORAGE RACKS FOR: FIRST CHOICE SERVICES 4471 134th PLACE TUKWILA, WA. 98168 PER CBC 1997 EDITION STORAGE RACKS CAPACITY: 4000 # / LEVEL RACK "A" 2500 # / LEVEL RACK "B" CALCS. 1 THRU 5 DRAWINGS: RD 8724 EXPIRES 12 -26 -05 nIryR�FTtm,vilq APp9 `. .7 Zoo PERM!T CENTER • By G. OHANIAN DATE 4-17-04 SUBJECT. Rh 1K DESIGN & ENGINEERII. CO. 3786 LA CRESCENTA AVE., SUITE 204 GLENDALE, CA. 91208 TEL:(818)957 -2980 FAX:(818)957 -8603 SHEET NO.. 2 JOB NO. RD -8724 O 10 \ \ 144" 1 1.8689 4000 # /LEVEL as ■ 1U75 RACK A 106" L8485 i RACK B 4 4 4 f 44" 1 44" 1 44" � � 44" 4, ... •,, 4. ay. G. OHANIAN DATE 4 -17 -04 SUBJECT. RAL,At DESIGN Sc ENGINEERING. CO. 3786 LA CRESCENTA AVE., SUITE 204 GLENDALE, CA. 91208 TEL:(818)957 -2980 FAX:(818)957 -8603 SHEET NO. 3 JOB NO.. RD -8724 485 BEAM 2500 # /LEVEL +25% IMPACT LOAD 1500 # /BEAM 689 BEAM 4000 # /LEVEL +25% IMPACT LOAD 2300 # /BEAM UBC 1997 SEC. 2222 Ix =2.1 Sx =.9 Fy =50 KSI. Ix =4.9 Sx =1.6 Fy =50 KSI. SEISMIC DESIGN V= 2 5xCaxl x W Rx1 •4 WORKING 1 =1 STRESS R =5.6 LONGIT. DIR. (MOM. CONN.) R =4.4 TRANSV. DIR. (BRACED) Ca =.36 W= D.L. +L.L. W= D.L. +L.L. /2 WHEN MORE THAN 4 COL. LOAD PER COLUMN p= 3x4 K_6 K RACK A 2 col W =.1 D.i 6/2 LL . 3.1 K V = 2.5x.36x3.1 — .35 K LoNCa. 5.6x 1.4 o M_ 106 "x1.5K_ 20-K 8 wK S R= 20 _ .7 <.9 A = 5xWxL3 = .4" < 106 = .58" 384xIx xE 180 M= 144 "x2.3 K= 42-K 8 S R= 30wK = 1.4< 1.6 A = _ 5xWxL3 = .6" <144 = .8" 384xIx xE 180 LONGIT, SEISMIC 0 w 0 to V = 2.5x.36x6.1 _ .9 K TRANS. 4.4x1.4 p= 2x2.5K-2.5 K RACK B 2 col W =.1 D.L 2.5/2 = 1.4 K V = 2.5x.36x1.4— .16 K °M IT' 5.6x1 .4 V = 2.5x.36x2.6 _ .4 K TRANS. 4.4x1.4 McoI= .16x70 " =1 1"K 17 K K 6 07 K gK 1 1'K .35K OHANIAN DATE 4 -17 -04 SUBJECT. RA A., DESIGN & ENGINEERING CO. 3786 LA CRESCENTA AVE., SUITE 204 GLENDALE, CA. 91208 TEL:(818)957 -2980 FAX:(818)957 -8603 SHEET NO. 4 JOB NO RD -8724 COLUMN ANALYSIS LU75 Fy =50 KSI A =.8 Sx =.8 rx =1.2 ry =1 Ki _ 60 = 50 rx 1.2 KI _ 54 =54 ry P ° — Pn - 18 K 1.92 Max =Sx•Fb = 24 "K COMBINED STRESS RATIO P + M 18 + 24 = 1<1.33 Pa ax BASE PLATE ANCH. TENSION = (11 -3.1 Kx3 ")/6 " =.3 K ANCHOR SHEAR = •9 = .5 K 2 (2)-1/2"01 WEDGE TYPE ANCHORS HILTI KWIK II ICBO #4627 (NO INSPECTION REQ'D) DESIGNED FOR 1/2 STRESS M 5/8; - • -x LU25 Fy =50 KSI A =.5 Sx =.S rx =1.1 ry =.8 KI_ 72 —65 rx 1.1 KI _ 54 =60 ry .9 P ° =11-12 Pn 2 =13K Max =Sx.Fb =15 "K P + Max— + 15 .9<1 .33 ax 6 K 5 "x7 3/4 "x3/8" BASE PLATE RACK COLUMNS DESIGNED SUCH THAT IF THE FRONT COL. IS DAMAGED THE REAR COL. HAS EXTRA CAPACITY TO SUPPORT THE FULL LOAD OF THAT BAY (UBC 2222 -5) MOMENT AT BEAM CONNECTION M 17 +15 _ 16 "K ,= 2 7/16110 RIVET A =.1 Va = .1x79x.4 = 3 K F y = 79 KSI 7 /16"r RIVET ASTM A354 -79 2 PIN CONNECTOR Ma = 3 K 4 , , 1 3 3 = 16 "K CONN. by, . OHANIAN DATE 4 -17 -04 SUBJECT RAGA DESIGN & ENGINEERING CO. 3786 LA CRESCENTA AVE., SUITE 204 GLENDALE, CA. 91208 TEL:(818)957 -2980 FAX:(818)957 -8603 SHEET NO. 5 JOB NO RD -8724 TRANSVERSE SEISMIC (OVERTURNING RACK A) MOT — .9 Kx2 x 180 "x.5x 1.15 =186 "K COL. MR = 6.1 Kx44" =268"K (OVERTURNING RACK B) M =.4 Kx2 x144 "x.5x1.15 =66 "K OT COL. MR = 2.6Kx44" =114"K LOAD TO DIAGONAL P =.9 Kx2 x 56 = 2.4K coL. 42 Fy =50KSI A =.31 rx =.48 Q =.74 L= 56" CHECK WELDS Fa= 11.2KSI Pa= 3.5K TOP LEVEL LOADED ONLY MOT = .6 Kx 180 " = 108"K MR = 2.1 K x44'_ 92"K 1/8" WELD 1.5" LONG EACH SIDE (3" TOTAL) 3x.125x.7O7x70x.3= 5.7 K CHECK SLAB 6000 5" CONCRETE SLAB 2000 PSI. CONC. 1000 PSF. SOIL = .4Kx144 "= 58 "K MOT MR = 1.5Kx44' =66-K UPLIFT =.4 K NO UPLIFT BOTH SIDES TYP. 7 t =.07- SEC. A -A SEC. B -B 6000 = 6 ° 6x144 =864 °" 1000 V 864 =29" M= (12 ) 2x 1000x 2 x12 = 204214 5= 12x52 =50 6 2042 = 41 < 1.6 x/2000 =72 . 50 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D04 -135 PROJECT NAME: FIRST CHOICE SERVICES SITE ADDRESS: 4471 SOUTH 134TH PLACE DATE: 04 -21 -04 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # afteribefore permit is issued DEPARTMENTS: Building Division E] Public Works ❑ 5 itg 44 Prevention Structural ❑ Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete 0 DUE DATE: 04 -22 -04 Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Qf Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 05 -20 -04 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing sllp.doc 2 -28.02 PERMIT COORD COPY F625-052-000 (5.971 V--G _5 DEPARTMENT OF LABOR AND INDUSTRIES REGISTERED AS PROVIDED BY LAW AS CONST CONT GENERAL ;. REGI ST . ## EXP ..DATE CC01 NORTHWH275JF 10/09/2005 EFFECTIVE DATE 04/06/1973 NORTH WEST HANDLING SYS INC 1100 SW 7TH ST RENTON WA 98055 -2939 Detach And Display Certificate REGISTERED AS PROVIDED BY LAW AS CONST CONT GENERAL REGIST. # EXP. DATE CCO1 NORTHWH275JF 10/09/2005 EFFECTIVE DATE 04/06/1973 NORTH WEST HANDLING SYS INC 1100 SW 7TH ST RENTON WA 98055 -2939 Signature Issued by DEPARTMENT OF LABOR AND INDUSTRIES Please Remove And Sign Identification Card Before Placing In Billfold 4P i°L�q ..:::. � Z }I--Z W 6 JU U0 co J H WO uQ to g W ' Z= 1-- 0 Z I— LL! ui U0 O N • 1-- W W X LL 0 •• W U= 0'' Z as14nyk+K. vn+.. �•. •e••• i• : .•.•��. • ▪ • r: ▪ . • 4:: •:• . •.a.•. • • 1 • 1.••• ' i� • 7 • 7M `M i• r r •.. •• ... • •• ... • •, •••• ..1••• . �• •: •.•.. . . •• �.,.• • •. :::. :'. 1• • • •f :.•:••'••• : : :: • -08 ‘N'••. '. •AA -+ . 4 . •. •. • • • • • 1 • tr .1 • 2c'.- o� --5/ - '''. ------ --&j.i.7*.tii• .1e. 1.40"P•.7 . t,... 4 $; l *n r»w f sir Ai. • ' 1'. i i 40' 80' 40' 1 44X106 1 44X106 I 44X106 I EXEC Tift( 1 OFFICE AREA 1 44X106 44X106 44X106 l6 ` 7// 11'-8" PLAN VIEW SCALE: 1/8" = 1. -0" SEPARATE PERMIT REQUIRED FOR: O MECHANICAL "ELECTRICAL O PLUMBING O GAS PIPING CITY OF TUKWILA BUILDING DIVISION Selegt5141 tio &WOES SW' iditt4014M014 ;I'bri2E CV V77.14( 01111V/44. rs } M$i 100 Wal.106 GN O %MIA COVED A PR 2 9 2 a�holor 61140 MIN"' FILE COPY I understand that the Plan Check approvals are subject to errors and omissions and a prooval of plans does not authorize the violation any adopted code or ordinance. Receipt c acknowledged. tractor's copy of approved plans BY D y�� Permit ate No. PI/ 'LI El t.T. RFCiF 414.1941/ CliCtr? �TFp A • • SHEET DESCRIPTION PROJECT TITLE 0 R �D ' RACK LAYOUT CHOICE FIRST • . 4..L.,), ,0� ANCHORAGE 1 NORTHWEST Z SERVICES . PORTLAND I ; '' SPOKANE z H tJ D l f it f m m SCALE AS SHOWN REVISIONS NOT PUBLISHED. ALL RIGHTS RESERVED. THESE DRAWINGS, SPECIFICATI• S. IDEAS, DESIGNS. AND ARRANGEMENTS 100 SW 7TH STREET EUGENE MMINAh rn THEREBY ARE AND SHALL REMAIN THE PROPERTY OF NWHS. NO PART THEREOF SHALL BE REPRODUCED, COPIED, YA K f M A cr DATE 4/19/04 ADAPTED. DISCLOSED OR DISTRIBUTED TO OTHERS. SOLD PUBUSHED OR OTHERWISE USED WITHOUT THE PRIOR RENTON WA 98055 DRAWN BY KEITH WERNER WRITTEN CONSENT OF NORTHWEST HANDLING SYSTEMS. (425) 255-0500 DRAWING NUMBER ..r wn �Y gas•. �- , i:4+j�.. ✓✓w-+ 90TH SIDES TYP. t' /2 t =.or SEA, A- A /8 V1.5" o� $EC. B-6 131 BRACE TO COLUMN CONN. • R • • • .• • • 4 • • ' • •4 • • • • r4 4 r• • 1/8 V 6" 7 3/4" 1 (2) -1/2 ". ANCHOR BOLTS PER BASE PLATE 3 1/2" EMB., (SEE NOTE NO. 4) BASE PLATE RACK " 144" 4000 if/LEVEL 1 • TH'K =3/ 3" FY =36 KSI. (ASTM A -36) 0 11 0 7/16 "4 RIVET ASTM A354-79 2 * Co BEAM CONNECTION TH'K= 3/16 " - -rte/` --- oc f 4 • • • • .• f • J • '1 d • r•1 • • 0 • • 4 • • . •. • .• • 1 I . • • 4 .• • . N 4. 3 1/4" t .• 1/81/ (1) -1/2 "0 ANCHOR PER BASE PLATE 3 1/2" EMB., (SEE NOTE NO. 4) BASE PLATE RACK 44" TH'K =1 /8" FY =36 KSI. (ASTM A -36) 3" LU75 1- - 1 5/8" Atg LU25 — d1 1 3/4" 2 3/4" LB485 s W 1 3/4" 2 3/4" L6689 • COLUMN SECTION BEAM SECTION • • • • • • 4, • I � 1 • • • 3r ° 0 '.\ '▪ 00 6410 ft . 'a • JI 0 '" ` V! 0 1 i! 1 0' • 1 / �� �0A `a `Qa 4Il ` a O• r • Agi ' • • • r • • • • • • • GENERAL CONFIGURATION 440 ROW SPACER .1- DESIGN OF STEEL STORAGE RACKS AS SHOWN BY THESE DRAWINGS AND CALCULATIONS ARE IN COMPLIANCE WITH THE REQUIREMENTS OF THE UBC 1997 EDITION 2 -STEEL FOR ALL SHAPES FY =50 KSI. ASTM A570 -85 GR.50 (EXCEPT AS NOTED) 3 -ALL WELDED CONSTRUCTION IN A SHOP OF AN APPROVED FABRICATOR (E70Xx ELECTRODES) 4 -ALL ANCHORS HILTI KWIK -II IC80 #4627, OR RAMSET TRUBOLT WEDGE TYPE PCBO #1372, (NO SPECIAL INSPECTION REQUIRED) 5- CONCRETE SLAB 5" THICK 2000 PSI. SOIL BEARING CAPACITY 1000 PSF 6- STORAGE RACK CAPACITY 4000 # /LEVEL RACK "A" 2500 # /LEVEL RACK "8" 7 -ALL RACK INSTALLATIONS SHALL DISPLAY IN ONE OR MORE CONSPICUOUS LOCATIONS A PERMANENT PLAQUE EACH NOT LESS THAN 50 SQUARE INCHES IN AREA SHOWING THE MAXIMUM PERMISSIBLE UNIT SHOWN ON ELEVATIONS 8- STORAGE RACKS SHALL BE INSTALLED WITH A MAXIMUM TOLERANCE FROM THE VERTICAL OF 1/2" IN 10' -0" OF HEIGHT 9 -THE CLEAR SPACE BELOW SPRINKLERS SHALL BE A MINIMUM OF 18 INCHES BETWEEN THE TOP OF THE STORAGE AND THE CEILING SPRINKLER DEFLECTOR. 10 -RACK COLUMNS DESIGNED SUCH THAT W THE FRONT COLUMN IS DAMAGED THE REAR COLUMN HAS EXTRA CAPACITY TO SUPPORT THE LOAD, (SEC. 2222 -5) 2500 II/LEVEL RACK "A" vt SIDE VIEW , •• • } .. . .R ', • .. r... . ..• .' .. • j ', .� ' .�..• .)ablimates.ki _ti a .iris,*.t..eari. .' 3 •ia•e.....;:.. RACK "B" • SIDE VIEW DATE REVISION CIS EOON AND NINEERDNO an us oiweoI.. AVE ..s. oUINs.L. CA. 91110111 AVE: 4-17-44 ROJECT. `DRAWN BY. A.KN. FIRST CHOICE SERVICES 4471 134th MACETUKWILA, WA. 98168 8 NO. RD -8724 STORAGE RACK DETAILS rSHEET No. rt