Loading...
HomeMy WebLinkAboutPermit D04-149 - WASHINGTON HOLDINGS - YGNITION - TENANT IMPROVEMENTYGNITION 565 ANDOVER PARK WEST D04 -149 !1'rq�i•�i LT �•:1 •.li., .1 dv`I:r4�Yttir . CITY OF TUKWILA Department of Community Development Permit Center — Building Division — Public Works Department 6300 Southcenter BI, Suite 100 Tukwila, WA 98188 (206)431 -3670 DEVELOPMENT PERMIT Parcel No.: 2623049144 Site Address: 565 ANDOVER PK W TUKW PERMIT NO.: D04 -149 Issue Date: 06/03/2004 Permit Expires On: 12/03/2004 Tenant: Name: YGNITION Address: 565 ANDOVER PK W, Tukwila, WA Owner: Name: WASHINGTON HOLDINGS Address: 600 UNIVERSITY ST, #2820, Seattle, WA Contact Person: Name: RON GREENE' Address: 600 UNIVERSITY ST, #2820, Seattle, WA Contractor: Name: S G A CORPORATION Address: 1501 N 200 STREET Contractor License No.: SGACO * *084BS Phone: 206 613 -5365 Phone: 206 613 -5365 Phone: Expiration Date: 01/10/2006 DESCRIPTION OF WORK: BLANKET PERMIT — TENANT IMPROVEMENT — NO STRUCTURAL TO CORE /SHELL OF BUILDING. Value of Construction: $120,000 Type of Construction per UBC: VN Uniform Building Code Edition: 1997 Fees Collected: $1,828.99 Occupancy per UBC: B Type of Fire Protection: SPRINKLERED Public Works Activities: Curb Cut /Access /Sidewalk/CSS Y/N Fire Loop Hydrant Y/N Flood Control Zone Y/N Hauling Y/N Land Altering Y/N Landscape Irrigation Y/N Moving Oversize Load Y/N Sanitary Side Sewer Y/N Sewer Main Extension Y/N Storm Drainage Y/N Street Use Y/N Water Main Extension Y/N Water Meter Y/N Channelization /Striping Y/N Number: [insert number] Size (inches): [insert size] Start Time: [insert start time] ....End Time: [insert end time] Volumes: Cut [insert cut volume] c.y. Fill [insert fill volume] c.y. Start Time: [insert start time] ....End Time: [insert end time] Private: Y/N Public: Y/N Private: Y/N Public: Y/N Mee hl CITY OF TUKWILA Department of Community Development Permit Center — Building Division — Public Works Department 6300 Southcenter BI, Suite 100 Tukwila, WA 98188 (206)431 -3670 PERMIT NO.: D04 -149 Permit Center Authorized Signature: , }1U�--7-Ce.--e_- Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The grant'. • of this permit does not presume to give authority to violate or cancel the provisions of any other state or local s re'! ulating construction or the performance of work. I am authorized to sign and obtain this development per it. Si ' nature: Print Name: 0 G Date: L 1 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. CITY OF TUKWILA Department of Community Development Permit Center — Building Division — Public Works Department 6300 Southcenter BI, Suite 100 Tukwila, WA 98188 (206)431 -3670 PERMIT CONDITIONS PERMIT NO.: D04 -149 Status: APPROVED Parcel No.: 2623049144 Applied: 05/05/2004 Site Address: 565 ANDOVER PK W TUKW Issued: 06/03/2004 Tenant Name: YGNITION ** *BUILDING DEPARTMENT * ** 1. No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 2. Plumbing permits shall be obtained through the Seattle -King County Department of Public Health. Plumbing will be inspected by that agency, including all gas piping (206 -296- 4722). 3. Electrical permits shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (206- 248 - 6630). 4. All mechanical work shall be under separate permit issued by the City of Tukwila. 5. All permits, inspection records, and approved plans shall be available at the job site prior to the start of any construction. These documents are to be maintained and available until final inspection approval is granted. 6. Any new ceiling grid and light fixture installation is required to meet lateral bracing requirements for Seismic Zone 3. 7. Partition walls attached to ceiling grid must be laterally braced if over eight (8) feet in length. 8. Any exposed insulation backing material shall have a Flame Spread Rating of 25 or less, and material shall bear identification showing the fire performance rating thereof. 9. All construction to be done in conformance with approved plans and requirements of the Uniform Building code (1997 Edition) as amended, Uniform Mechanical Code (1997 Edition), and Washington State Energy Code (1997 Edition). 10. Validity of Permit. The issuance of a permit or approval of plans, specifications, and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. Th= granti ' g of this permit does not presume to give authority to violate or cancel the provision of any other work or I • al laws regulating constructio or the performance of work. ignature. Print Name:? \sierra \permits \permit conditions s; �.vAe•L45a.9 Lt Date: ( /3 �d y March 26, 2001 CI T. )F TUKWILA Department of Community Development Building ,Division- Permit Center 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431 -3670 Blanket Permit Tenant Improvement Application ALL APPLICATIONS MUST BE FILLED OUT COMPLETELY (Shaded area for Offlte Use Only) PLAN REVIEW' U i1'�I..,r ;'.', , ;.. .,..,. :. lv irk IC'1.4i r / t . I .i1 ; r . ± .,; • :, .,5, ,� ,11, t /r,', rte, �t'., , {,a }' ;•,... . ..1; n'. .;.N,?Yl.�l. d, )'kk3 .,,, ., , }f "f 1,' • d ,.t 1 •.1 11 it!�•,,, 1.' "� ,. �', I 1. . .� "(li,1'' vs 1. , . #, , ,i t')C(y , i %"' t . , ,, ,, , �t, :• �,, , i,,. •l f, 'E l(i:j e ;.01,6 .' 4 Y 1.A ll, S „,r:, ,i!1 . • 'f!1,'L il� { i i'= �f.s r'' t,ll ,� 1 'r..r ;�; A OU,ftTi r +; ;<I, I;t�'s� : �, �rj�g �'��:... . I.,� .t, o� ( • \r ' ' , ' ,r''r'�So''14:Pi t r ,,,.,r, ' °,la CP' i :, rit ':� �,�I�.•.�,f )}'�7��f��y,,��. 'r O t 4 ;g tir •itD,U ,.,�„ di n: f• i t. a.,. r �'-� }'k t, �,, D'j�'�� ~<t) Mi iPil 1 (., ;1( sl SY3'nv ,?t �i4,� i, -( f�• .l <C r., , ' It .rM' ` a,'. 'I•... n:� (: � g�' �, ,• ;t • t': e „ �. '.0? s''' '''.' "1 *C1t'J:,fll'Vi. l''. .{ t 1 ��i 7�•t p BGt >1ti�;P1!,ett>atfi�bt, (k•r,. ,r( .•V' Nt 1'f', f 'll �r1.1t1 Ilt 5 _ w i s I �' ,lin,Cliebk Fe:C v {f., !, '':;,,i'i r ;t, ;r; •ia is }P, ., L .Z2, `F� �'�� .t � �:., • 0 ;. ,. yYi r?Jr� C�` 7 't , ,:; ( `� < #'•F`' Yn, .; ` 7,i;: "f•� ' k y'' •ai''r ". t; -.'ti` 1 A "• s •., n A�l� '.A' !wd� 2 i _:�: �il� fi, .� -�'; '`� `,`" Ra +i.' it t 'r .,.`i,' .v31,(L�, 7,. . .�_t :r; ''.'lt' e)!;S j a.;5Y4.t,, . ,vi ±.. 1,. y • :,,r.: �, f BLANKET�PERMIT�AG�tEEMENT,l�O ;.� V�,1.' 4 1r ' .. ., .•'w) .. , ,,.Ira,' Y,,t1 `. `' .,54 1:,, "7`+I. '`Builditi{j1[1 li;dNar �'.�`,',1,.,:t ,k }I„1, .1 Cr.� 8. i1 Y ,,,,,,,,,,,,,„,,,„,,,,,t ' t�.liS „if •':„Y� : if I.t•,• t+,.,7 '. gazi ;s ,$:�;.�,,�r °'�,'''�'�: '4;50; .. :! 1 ./t f I .V L 1 ' 11I' \ �,'; 'l' ..,,1 r. ,,t �:,',t I. .. I�., _,''�;ti'��;;'-: � 1Ctl y( , { ,\ t \., "�. y..lt\',Ir 11•( ^2 AA �;,,.1;' , 'i � 1 , . (t'„i 'l l ,,.t {II 5.,'1'S'` .,{,51 ,... . 1'. ',f:. t " , `,r " ,k 'r,.,d.'fit.' �� i r•,i �% t. .} !, 'I.' f !. •: ,, T tki,,., :M ?, ,,•� ?,:. 1F r,'.r,',11,;'; "-' _x .• I J� t e' Yr; {i. ,, f' ; `XI} f 1 1'ti.1 �'tF.il.,•,It l,: ,p�rl ,Q, fu;, t, .y; i .'1,.; h..'l.f �:, s.,;;,i., fl ;''. ik, f r d i 1.Y ; a. • °, f.'Si:: !vic , �v .s , •,,tl.t,y,l�,.<I�,Ef, ,,,,rr�'.'lkltt.( k`r ,1' ; i,.; I ?, r!, ti tr, ''.f .' "„ iii., r'i J ,t :i'. !:xl' ,-),' + :'. S.. )r !h'j^ 'A':3 •'� I'S r ,t;•..;� ,1, ,�t ., �,Gl 1�� ..t.rj'ii" .,,..,. .i':tx '' ` :J ' .,, ... s :z,; }7' .�.' i.: 1; f r. .�1�t }[[ trt,r,a, ..'ln I :;!1( '7, {;!" t: qa'', � i ' "pl .r, i) g.: .� : }' ( (... ty t': i., :'.. .. ': i,f.i'', .I.r ,.f ,� ".:, ,ti ,I:: ,:�� }:...(,,...,, a;::Ttifal., .r':.,, r, ;t;.:., :l. k'' • ';'i :j''i'�;. ,•t:, ;; s {1i,d'`''rr(i t I, T}`t :1 i'}' ,i ;�.. )�y/�;� " I :i•lij }t }''�. !il, .' /��t }.y}� 2 t rLA1 "T'!'� . :l ,1, �+�% �1J. ;t. 'i7t'7 {.' Site Address: Value of Construction: $ `24 6/C° Assessor Account No.:26'Z 90411,44..a Floor: a �/ Suite Number: Project/Tenant Name: I�7.'l1 l(;,Jyi` -1 Type of Work: IX Tenant Improvement ❑ Interior Demolition ❑ Other: Describe work to be done: "Co COMIOHELL. 15 but L. Building Type: uilding Use (office, warehouse, etc): D 0e Nature of Occupancy (printing, manufacturing, etc): t'b t g, i0 tc S *- quare Footage: Entire Building: Construction Area: c t ) 2 ZZ Tenant Space:1 1 222 Will there de a change in use? g No ❑ Yes If "yes ", explain: Will there be rack storage? 'No ❑ Yes Existing Fire Protection: j Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? No ❑ Yes If "yes ", please explain: Will there be ANY structural work? KNo ❑ Yes If "yes ", please describe: PROP ( T OWNER:. g HVIXA 1,140 Phone No ( 96) tot 3 %- e., Z5 � "r P Print 1 A t G f 2'-G_ Ci /State /ZiP : Cr °tSlg Address: acy.ut y 120 CONTRACATOR: s-.64_ l E--) City /State /Zip Phone No: ( ) Address: City/State /Zip: WA State Contractor's License No.: Expiration Date: ARCHITECT: MAIM/ li4 orvt4 fre Liz, Phone No: ( ) Address: 2..21 YE, I �A .' City /State /Zip:. Expiration Date: -" t 2' 1 WA State Architect's License No.: I hereby certf that I have read and examined this application and know the same to be true and correct, and 1 am authorized under Blar�k�P mit Agreement No. A to apply for and obtain this permit. Si ature:( \ _ ,_ ,_-- Organization: Print 1 A t G f 2'-G_ Phone No: -,, Address: 600 UU \ v-Q J ' 1-1-t `�"r- e e 1 ere-A-4-4 l E--) City /State /Zip So -i --e 2_8 481 See reverse side of application for specific plan submittal requirements and information. Date application accepted: ' Date application expires: 04/24/00 CITY nF TUKWILA Depal ...vent of Community Developmt..t Building Division - Permit Center 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431 -3670 Blanket Permit Agreement Tenant Improvement Application Attachment 1 - Architects Statement PLAN REVIEW NO.: „1„,041-197 � PROJECT NAME/ 7Gi,ArrieD.1,1 TENANT: BLANKET PERMIT AGREEMENT NO.: Q'��DDI"�P�' COMPANY prp� JOB NO.: Is d 11 ll • SITE ADDRESS: 0 No P . `'J T wi Business Phone: afito 441 1411 Is any part of the work proposed under this application include structural work of affect structural components of the building? 0 Yes X No If yes, has the structural work been authorized by the Tukwila Building Official to be included in this application? 0 Yes 0 No Does the proposed work comply with the requirements of Chapter 10 of the Uniform Building Code (1997 Edition)? Yes 0 No If no, please explain: Business Phone: afito 441 1411 Street Address:227.1 111/1 AM. City /State /Zip: OEA 1 `! . c S1 z l Will any special inspections be required per Chapter 17 of the Uniform Building Code (1997 Edition)? 0 Yes 38( No If yes, list specific inspections: As a result of this proposal, does the parking meet the requirements of the Tukwila Zoning Code parking requirements? Yes 0 No If no, please explain deficiency: Architect/Engineer 5876 Stamp: ' REGISTE;:: :J ARCHITECT - ' J. SI PSON •FWAS ING'io :a Architect/Engineer Signature: I .11.• �.OP' Print Name: WM e( -. .% Firm Name 1? ?AV t �1 � 1$ 4 . L. WILL STA Business Phone: afito 441 1411 Street Address:227.1 111/1 AM. City /State /Zip: OEA 1 `! . c S1 z l 03/22/00 Blanket Permit Architect Statement CI' ' OF TUKWILA Department of Community Development Building Division- Permit Center 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431 -3670 Blanket Permit Agreement Tenant Improvement Temporary Inspection Card Plan Review No.: ,DO ce--/49 Date Issued: 5-„c-0 ci/ Blanket Permit Agreement No.: 0,11r 00 /'-4f42/9 Project Name /Job No.: / 1.. Site Address: o AIDO �E2 ,24 / CALL FOR INSPECTIONS AT LEAST 24 HOURS IN ADVANCE (431 -3670) (Have Plan Review number, Blanket Permit Agreement number, project name and site address ready) "X" REQUIRED INSPECTIONS DATE APPROVED INSPECT INITIALS PLANS DATE DATE(S) CORRECTION NOTICE ISSUED )( 1. Framing 2. Insulation X 3. Suspended Ceiling X 4. Wallboard Fastening DO NOT PROCEED BEYOND THIS POINT UNTIL THE BUILDING PERMIT IS ISSUED. PERMIT MUST BE PICKED UP WITHIN 24 HOURS OF NOTIFICATION THAT THE PERMIT IS READY. CONTRACTOR/APPLICANT BEGINS WORK AT THEIR OWN RISK PER THE TERMS OF THE BLANKET PERMIT AGREEMENT. INSPECTIONS 1. FRAMING - After rough -in inspections such as mechanical, plumbing, gas piping, electrical and fire stopping is in place. 2. INSULATION - After framing approval, but before insulation of wallboard. Baffles must be installed to keep attic ventilation points clear. 3. SUSPENDED CEILING - Fasten diffusers, lights and seismic bracing. 4. WALLBOARD FASTENING - Prior to taping (See UBC Chap. 25 and Table 25G). 5. PLAN CHECK INSPECTION - Immediately after the Tenant Improvement Permit is picked -up by the applicant. Work may not proceed until the City Inspector delivers the plans and new inspection card to the site. This inspection should be scheduled at the Permit Center when the permit is obtained. • Construction will not proceed past required inspections. • The Building Permit and approved plans shall be picked -up by the applicant within 24 hours of notification that the permit is ready. Failure to do so may result in a stop work order. • Construction may not deviate from that shown on the plans as submitted at time of application. • All corrections shall be made within three (3) days of notification by Building Inspector. • No more than 30 days shall elapse between the last required inspection and the "Building Final." • Unauthorized occupancy and /or use of the remodeled area shall not occur until the Building Inspector completes the "Building Final," which takes place after the Building Permit and Permanent inspection Card has been issued. • The City reserves the right to stop work at any time that in its judgment the work presents a safety problem, warrants a building permit prior to continuing work, is not proceeding according to approved plans, or otherwise would not qualify for consideration under the blanket permit process. • The following work is not covered under the blanket permit process. This work shall not start until approvals and permits are obtained through the applicable agencies, under their normal process: Electrical Department of Labor and Industries (248 -6630) Plumbing /Gas Piping King County Health Department (296 -4722) Fire Protection City of Tukwila Fire Department (575 -4404) Mechanical City of Tukwila Permit Center (431 -3670) Rack Storage City of Tukwila Permit Center (431 -3670) THIS IS A TEMPORARY INSPECTION CARD ONLY AND WILL BE REPLACED BY A PERMANENT INSPECTION CARD WHEN THE BUILDING PERMIT IS ISSUED. 11/01/99 Blanket Permit Inspection Card L GENERAL INFORMATION This tenant improvement application may be submitted for non - structural interior construction which is authorized under an existing approved blanket permit agreement. It is the responsibility of the applicant to be aware and comply with all the terms and conditions as set forth in the agreement. The work is limited to that shown on the plans as submitted with this application, and such work is limited to non- structural interior construction only. The following work is not covered under the blanket permit process and separate approvals, permits and inspections are obtained through the applicable agencies. ELECTRICAL - Department of Labor and Industries (248 -6630) PLUMBINGIGAS PIPING - King County Health Department (296 -4722) FIRE PROTECTION - City of Tukwila Fire Department (575 -4404) MECHANICAL - City of Tukwila Permit Center (431 -3670) RACK STORAGE - City of Tukwila Permit Center (431 -3670) BUILDING PERMIT APPLICATION Application Submittal - Application and plans must be complete in order to be accepted for plan review. Make sure to fill out the application completely and follow the plans submittal checklist which follows. Handouts are available at the Permit Center which provide more in -depth detail on preparing the submittal. Authorized Agent - The applicant must be an authorized agent as identified in the Blanket Permit. Fees - The permit fees are based on valuation of construction as declared by the applicant on the application, and shall include all the work to be covered under the permit. The valuation will be reviewed and is subject to revision by the Building Official to insure compliance with current fee schedules. To obtain a fee schedule, contact the Permit Center at 431 -3670. SUBMITTAL CHECKLIST 1 Completed Building Permit Application Attachment #1 - Architects Statement . l' Three (3) sets of construction drawings, which include: ❑ Site Plan, showing: O Building location on property O Adjoining public rights -of -way O Parking layout O Location of tenant space or area of work within building 0 Overall dimensions of building O Overall dimensions of tenant space, or area or work O Name of each common wall tenant(s) and type of business or occupancy gFloor plan of entire floor or tenant space that the work is taking place, showing: O Tenant space layout with use of each room labeled O All exit doors, corridors and egress patterns O All new walls, existing walls and proposed walls (provide construction key) 0 All other proposed construction fq Construction details O Construction key Cross sections showing wall construction and method of attachment, floor and ceiling 0 Reflected ceiling plan (if applicable) ❑ Miscellaneous O 6" x 8" blank space provided on lower right hand corner of each page of plans (for use by the plan checker) O Title block on each sheet, identifying: • Project name • Company job number (if applicable) • Site address • Blanket permit agreement number • Architect, address and phone number O Each sheet of plans stamped by a Washington State licensed architect O Minimum sheet size 18" x 24" O Plans must be drawn to scale and clearly dimensioned Drawings shall be prints which are clearly readable (original pencil or highlighted drawings are not acceptable.) ❑ Permit Fees (plan check fee, building permit fee and state building surcharge) 11/01/99 Blanket Permit Agreement information City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: Address: Suite No: Applicant: 2623049144 545 ANDOVER PK W TUKW SOUTHCENTER CORPORATE SQUARE RECEIPT Permit Number: Status: Applied Date: Issue Date: 04- 001 -BPA PENDING 02/04/2004 Receipt No.: Initials: User ID: R04 -00115 SKS 1165 Payment Amount: 2,500.00 Payment Date: 02/04/2004 11:15 AM Balance: $0.00 Payee: WASHINGTON RE HOLDINGS LLC TRANSACTION LIST: Type Method Description Amount Payment Check 749 ACCOUNT ITEM UST: Description Account Code 2,500.00 Current Pmts BUILDING - NONRES 000/322.100 2,500.00 Total: 2,500.00 flTA 25)T,4,0 doc: Receipt Printed: 02 -04 -2004 City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: Address: Suite No: Applicant: 2623049144 565 ANDOVER PK W TUKW YGNITION RECEIPT Permit Number: Status: Applied Date: Issue Date: D04 -149 PENDING 05/05/2004 Receipt No.: Initials: User ID: R04 -00541 SKS 1165 Payment Amount: Payment Date: Balance: 1,828.99 05/05/2004 03:35 PM $0.00 Payee: WASHINGTON RE HOLDING LLC TRANSACTION LIST: Type Method Description Amount Payment Check ACCOUNT ITEM LIST: Description 891 Account Code 1,828.99 Current Pmts BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE 000/322.100 000/345.830 000/386.904 1,105.75 718.74 4.50 Total: 1,828.99 06 05/06 9716 TOTAL 1B20.99 doc: Receipt Printed: 05 -05 -2004 Z cc W 00 CO J H U) u. W0 2 a. = d. W Z= I— O ZZ uj • 0 O t• o O I-- WW u-O •• Z W 0 z INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit PER (206)431 -3670 Pro'e t/:' / /770/1/ Type of In,�Lpection: Address: /9/ /6/ Date Called: ( -/7 --,1 . _,1A/ Special Instructions: C1 Date Wanted: ' a.m. Requester: // Ph ne No: ) V Approved per applicable codes. El Corrections required prior to approva COMMENTS: Date' El $ .00 REINSPECTION F E REQUIRED. Prior to inspection, fee m st be paid at 6300 Southcentr Blvd., Suite 100. Call to schedule reinspection. Inspe Receipt No.: Date: 3 INSPECTION NO. INSPECTION RECORD Retain a copy with-permit PERfvf6TJ JO CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Pro j c o Type Inspection: Addriss:0 IRA iT f 60 Date Called: i i D �( Specia�ihstructions: Date Wanted: blog mRequester: nr\ Phone No: 4%4)0 Le -- j� 9 `T- ( --1-1-QQ7 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: p - ctor: _7 $47.00 REINSPE ION FEE REC,i.1IIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection. Date: eceipt No.: Date: 2 Z 00 W tO LL WO 2 J LL ?. ..a � W ?1.— WO W U� 0 N wW LI O w Z = 01- Z INSPECTION RECORD Retain a copy with permit p,.,,/,_. INSPECTION NO. PER O CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206 431 -3670 Pro' • Ilia Type i`I s ect•on: it.itAttia, ' FCC eta /n.3 Addr ss Sts 4. w Date Called: s/� a �� Special Instructions: Date Wanted: `/� /�1 . Requester: Phone No: giO - qli9- Yo47 Approved per applicable codes. Corrections required prior to approval. COMMENTS: cspect� r: 0 REINSPECTION FE RE Date:_ REQUIRED. Prior o inspection, fee must be at 6300 Southcenter Blvd., Suite 100. C II to schedule reinspection. Rece pt No.: Date: 9 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 D°4 -�4� Pro'e t: +1 Type of Insp7 i1 r}: (.._ ( �"G• Add ess Sao 4 -vdoVe l IA1 Date Called: 6112104 101Z Special Instructions: Date Wanted: m. 0. Requester: Anil Phone No: l,j .4D6- 614M -9O 7 Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: A r\li.--ixre--(-) 5 -• I Date: 1310y l 47. i 0 REINSPECTION >t`EE rior to inspection, fee must be a': at 6300 Southcenter B) Cali to schedule reinspection. REQUIRED. Blvd., 1 0. Receipt No,r Date: City of Tukwila Steven M. Mullet, Mayor Fire Department Thomas P. Keefe, Fire Chief TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM • Proj ect Name L- e: Af / T % OAI Address &-: >+= f li/ r -. Permit No. 1je, (4- f 7" ,. -. ��:- ti�--.:•_..- Ret. ain:.: current....inspection_.schedule Needs shift inspection Suite # Approved without correction notice Approved with correction notice issued Sprinklers: E' Fire Alarm: f40 Hood & Duct: /V Halon: /k7 Monitor: C-P'?a Pre -Fire: Permits: •L: 6/.7/61V Authorized Signature Date FINALAPP.FRM Rev. 2/19/98 T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206 -575 -4404 • Fax: 206 -575 -4439 r 1997 Was.lttlgton State Nonresidential Energy Code Compliance Forrn Lighting Summary LTG -SUM 1997 W$thiplon Stara Narrn.OMNri Enemy Code Comprarna Fame Fast Edam •Arm 1998' Project Info Project Address ■ No changes are being made to the lighting • Allowed Watts x ft2 (or x If) Date 96P, 64 1 Watts • Proposed p, d f^JI i j `t' For Building Depa ntyll + ry T Q 2004 Op rt j4 F% eRm/T L'EN�.�R /� 10°1 Applicant Name: to f�tao 1� 1C • j Applicant Address: G'/' ►V ��`��� I 0.25 W/ft2 Applicant Phone: 0 t+% Bldg. (by perim) :. Project Description [0 New Building ❑ Addition' Alteration 'T 11 T ilt4ROVektti Compliance Option 0 Prescriptive Lighting Power Allowance 0 Systems Analysis (See Qualification Cheddist (over). Indicate Prescriptive & LPA spaces dearly on plans.) Alteration Exceptions (check appropriate box) Fixture Description ■ No changes are being made to the lighting • Allowed Watts x ft2 (or x If) 1 II Less than 60% of the fixtures are new, and installed lighting wattage is not being increased Maximum Allowed Lighting Wattage (Interior) F LE COPY Location (floor /room no.) o9s2. et Occupancy Description Watts per ft2 Area in 'ft2 Allowed x Area C., 1C 1. Z 41222. 11,O(( 4 From Table 15-1 (over) - document all exceptions on form LTG-LPA Total Allowed Watts Proposed Lighting Wattage (Interior) ,(May not exceed Total Allowed Watts for Interior) Location. (ftoodroom no.) Fixture Description Allowed Watts . per ft2 or per If Area in ft2 (or if for perimeter) Allowed Watts x ft2 (or x If) Number of Fodures Watts/ Fodure. Watts • Proposed 6 11_1 0 ",,rC"Ll "Lle 02 wntz 10°1 100 to f�tao 1� 1C • j ��� Bldg. (by facade) I 0.25 W/ft2 • CITY OF TUKWILA Bldg. (by perim) :. ►, — .. • APPROVU) 1Aa.,r ...� . - - 1 _ • r( a �r n S��1' t 1 .;"t Ai I'? +;iii_ V Maxim Total Proposed Watts may not exceed Total Allowed Watts for Interior Allowed Lighting Wattage (Exterior) Total Proposed Watts • Location Description Allowed Watts . per ft2 or per If Area in ft2 (or if for perimeter) Allowed Watts x ft2 (or x If) Covered Parking • 0,2 Wi1t2 Open Parking 02 wntz Outdoor Areas , 02 Wife A Bldg. (by facade) - 0.25 W/ft2 • . ' Bldg. (by perim) 7.5 WIIf • Note: for building exterior, choose either the facade area or the perimeter method. but not both) Total Allow • Proposed Lighting.Wattage (Exterior) (May not exceed Total Mowed Watts for Exterior) Location • Fixture Description Number of •Fixtures Watts! Fixture • Watts' Proposed A Total Proposed Watts may not exceed Total Mowed Watts for Exterior otal Proposed Wa ** Projects shall comply with lighting Control requirements in Energy Code Section 1513.6 �1'!`, rd6i��+ t91i1' �UCNq;' �Y�` ?+.$ t3. t' eaaeg±:l +r%%p,++a*",+"xt,ny.,.w wrc;t „*rr,:�•,.a.r�!a•n.:.r..n +rr.+v*arn',•w� r �,m,.r,: -. aa4�mA1Pr1l �Ilsllklllllllf- 11�r.r111eC1Y1M i.l.e lRll�lfamr nwkw .. ,. E- c711 w w • C7 E {- C/1 gal q --� E E� o O p a = d. a� �� cn g 0 L f~ — >• E- c:. O z o• C71 C to U O cv-a • PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D04 -149 PROJECT NAME: YGNITION SITE ADDRESS: 565 ANDOVER PARK WEST DATE: 05 -05 -04 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after /before permit is issued DEPA TMENTS: b-//0 A' 70 561641 Bui din Divi ion Fire Prevention Planning Division Public Works ❑ Structural ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 05 -06 -04 Complete [ Incomplete ❑ Comments: Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route [ Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 06 -03 -04 Approved 0 Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: PERMIT COORD COPY Documents /routing slIp.doc 2 -28.02 NQ?+ N }ita;itx;ifi�,wV.:Ya'o'X2��i' ,' MY .S`An.''+s{:raei�Yrf":i?�iuvz SENT BY: SOA CORPORATION; 2065332196; MAK-9-04 12:411-TI; eAut 2/2 ACEIMMEEISF • • , •• • , • 'DEPARTMENT OF LABOR AND INDUSTRIES'' . " • • 11, •••'s •• . • ' , .* • • • • • • • • • • " • .1 • • • • REGISTERED AS PROVIDED BY LAW•'•Ag••• ' • •• . • • • ;•::: • •-• . , .gotsjp. co • tr...-7.-:.•At' " - • • g a* Er tri4Vtat. 04.0,45.t ,1 • • • ..• •• ,••• :A., .. • .• .., • • E.FEEtTIVE DATE ., 0 1 . .. : : • • . • -1":. • • •• •1 •,• .:: -.•• ••• .-: • ' .. "':: ' 44. — . 1 ' ... ••: r'.. . ' .: - • . :. 5: G A CORPORATION •-• .:. ,. • „..., :%.1.•!•:•,,... • • ..... :' •-•• • ' .'• • • •-;*.•: •••••• '"•••" •• 1501 N 200TH ST ...• -....... • • - • • ...:• • :;'w:••• • . '.7.:%•••.....;:". •'' ' • • ':•:•,:•:•::••••4 *.- SHORELINE WA .98133 • 4 ' • . d4;":".F4'.. • . • • :.• ,*. • • 1254152-DOD itsN/i .g.r% . .." • • ..vf. • , • • •••••• • ".•:) *••:. f;i• • • • ",•-••• • ••• •.• .;/•-4,;. • ;.?:` • ' Dawn And Display ritilitlentr REGISTERED AS PROVIDED BY CONST CONT GENERAL • " REGIST. • # • EXP. DATE ' • CCO1•• SGACO*1,084BS oi/ipi2oos • EFFECTIVE..DAT. . . 01/10/1992: . .. • • ;•....: S G A CORPORATION •• 1501 N 200TH. ST . • •• SHOREL Signuiu Issued • EPARTMENT OF LABOR AND INDUSTRIES LAW AS! • Please Remove And Sign Identification Card Before Placing In Billfold z r i ACT ,ACOUSTICAL CEILING TILE AD.) ADJACENT/ADJUSTABLE Ai; MOVE FINISH Ft JOR ALT ALTENNATE ALUM ALJ' NLP1 APPRIOX APPROXIMATELY • AT BLDG BUILDNG & Gt CLOCKING B/6 BUILDING STANDARD GAD CABINET CLR CLEAIF/C4EANCE CLca GEILNG CL CENTERLINE COL COLUMN ccer CCI P1t$ICATION amp) COMPOSITION C0146T CONSTRUCTION CONT CONTINUOUS CPT CARPET CT CERAMIC OR CONCRETE TILE DIA DIAMETER DIM DIMENSION DR DOOF D(& DISHWASHER DWG DRAWNG E EXISTING, EAST EA EACH ELEC ELECTR'C ELEC'L ELECTRICAL ELEV ELEVATION (ViEIL) EXIST E >:T FIN FLR FLUOR FR FT FURN GA GALV GD Gl. GWB i NDW HM HST H•1vAC IN MCI. INSuL MT EXIST'■G EXTERIOR FINISH FLOOR FLUORESCENT FIRE RATED FEET FURN 5E»FJRN 5NINGS GAUGE GALv4NIZED GARBAYsE D,5P05AL GLASS'GLAZNG GYPSI/.W !y''�' WA _1_ �_ BOARD HOLLOW C HARDWARE HOLLOW I'1E TAL HEIGHrT HEATING, VENTILATING AIR COND TIONIMi Iii INCLUDE NSULATION NTER.DR JT LICE LF MAX MECH MFR MN M16C MTD MTL MW N N/A NIC NO NOM NTS OC CPNG OPP JOINT DY LAiNDLOtRD AT TENANT'S EXPENSE LINEAL FOOT MAXIMUM MECHANICAL MANUFACTURER MINIMUM MISCELLA FC+IJ6 MOUNTED METAL MICRO AVE OVEN NORTH, NEW NOT APPL iCABL E NOT IN CONTRACT NUMBER NOMINAL NOT TO SCALE ON CANTER oFENW1 OPPOSITE OR* ORIGINAL PERM PERMANENT PL PLATE PLAM PLASTIC LAMNATE PLYWD PLYWOOD PR FAIR PTR PARTITION RADIUS, R" HOVE, RELOCATE RB RIJN:5ER a ASE REF REFRIGERATOR WINE RE''v- DRIVING REQD REGJIRED REv RE'rISIONi,REvERSE RM ROOM RC ROUGH OFE•1NIG 6 SOUTI, SC-ED SCHEDULE" SC SOLO CAR SEC- SECTION gIN sfr!'_ aR SRC 8Q STD STL ETOR gUSP TEL TYP VCT VERT w UL' W/O WC SPECIFC.ATION SQUARE STANDARD STEEL STORAGE SU5FE'NDED TELEPHONE TYPICAL VINYL COMPOSITION TILE VERTICAL WEST WIN WiT► -►;BUT WALLCOVERING WOOD 6 ABBREVIATIONS I. ALL ELEMENTS Of FINISH✓ N=01214'1044 la COi"i!NG FRX"' THE TENANT 2 1/1' MTL. STUD BRACING • -1'-01 O G. 1-- 2 1/2' 20 GA. 'C' STUDS WI ero TYPE x GYP BD BOTH SIDES UL. *448 TENANT 1--6U5PENDED MIL ING SY'ST'EM Y 2 1/2' MTL STUDS W' 5/9' TYPE '/' GYP BD BOTH SIDES SOUS ATTENUATION BLANKETS 1 NF RATED CORRIDOR TENANT a 4 • .. . THIS CONDITION E!ISTS TI.E ONLY NEW I -HOUR CONSTRCTION( IS AT SUITE ENTRY (AT DOOR '01) 4. Z 111111111111111411111111111. - 4 a IEVE4 _ (lalA6tT BLANK! -- .•tttssastssasta I/E' ELAM FOAM TAPE HOLD SACK I/4' MOM EDGE OF TRACK METAL SW. STAGNI ED • E -Illy AG. ,OR 41.1.1INDRACIED dTRI►kWr F41� OF WO- OAR '2' ,r' - ATTACH TO 61RJCTUIE AlOvE LW APPROPRIATE FG ER MAN VEN PMTik as* ceNTwoua CEILING GRID - PO NOT CUT SUSPENDED CEDING 2 1R' X * GA. OTL 61106 • 24' OC. lU/ WO' GUS TYPE x . EACH SIDE NOTE: TYPICAL IrARTITiON HEAD WITHOUT WAGING SIMILAR • FASTEN TO CEILING GRID 3 1 PARTITION BRACING NTS HOUR RATED EXIT CORRIDOR I4VAC. 1. RECONFIGURE AS REQUIRED' FOR ALTERRT1ONS 2. RE'=.ALANCE NVAC SYSTEM 3. CLEAN ALL EXISTING GRILLES 4. YERIPr ANC RELOCATE T«.JEtZ'"tOSTAT Ae NECESSARY. N.T.S. FM LI 1Y: 1. .kL FIRE r.!TINGUiS+ERS, HORN STROBES EXIST 81C J5 AND SPRINKLER HEADS, ETC TO BE PER CODE'S LATEST R=_ QUIREMENT5. 11 FINISH NOTES 12 HVAC AND FIRE LIFE SAFETY NOTES gtr B/S WALL MOUNTED DUPLE/ ELECTRi :AL OUTLET 13/5 WALL MOUNTED DEDICATED '20v 20A DUPLE, ELECTRICAL CUTLET. B/S WALL MOUNTED FOUiP_E, ELECTRICAL OUTLET E/5 WALL MOUNTED Fa.RF-E>' ELECTRICAL OWLET IJ'T4 1.r1 ON SHARED SEPAR•:"E GIRC.: :T AND i/ ON STANDARD HOUSE PM ER (MAXIMUM! 4 OUTLET PER CIRC.:, T). • e/S WALL MOUNTED COMBINATION v10ICEIDATA OWLET (UP TO 6 LINES %. N 15/5 WALL MOl14TED vOICE LINE OUTLET. B/5 WALL MOUNTED DEDICATED VOICE LiNE OUTLET FOR FAX BLANK FACE PLATE EXISTING THREE -PRONG SPECIAL EQ'•:'PMENT OUTLET. GORE DR:- SYM9oLS AT' ACHED INDICATE SER'AC.'E REQUIRED. COORCNNATE LOGATCN WITH M UNI'S FURNITURE VENDOR. VERIFY OBS-Rlic-IONB PRIOR TO DRILLING. G. WHO CONECTION FOR SYSTEM FUR41TURE CONBHST(NG OF- - - A FJUIR'LEY ELECTRICAL OUTLET WITH ,/i ON SHARED SEPARATE CIRCUIT AND I/1 •ti ON STANDARD NCtIEE POLDER (MAXIMUM 4 OUTLET PER CIRCUIT/ (NPIBER QUANTITY OF WORK STATION* TO ISE SERVED). AND �-- A COMBMAT aN OF (1) YOKE AND (2) DATA OUTLETS 70 TE INTO TENANT'S FURNITURE 5/ITEM (NJMHER • Q1AN'1Y OF WORK STATIONS TO OE SERVED). 'E' EXISTNG TC !REMAIN. TE 4L OUTLETS TO BE MOUNTED ki' AFF. - TO BOTTOM OF OUTLET PER Hu513f. REQUIREMENTS, E►NTS, UJ4,O. 1. ALL DATA 4 COM"iLNICATION LINES TO Of IROUG14- M ONLY (VW RING JJ/ PULL ORE) 3. RE -USE E)R*!NG OUTLET'S AS NEEDED IF AT LEAST 0' FROM LOCATION SNOWIL, 4. FINAL LOCATICNb OF ELECTRICAL AND VOICE/DATA ARE TO BE INSTALLED AS REWIRED BY- LOCAL CODE. 3. 01JTLET* WITHOUT E' (Ex*STING TO RE'MAN) AIRE NEW OUTLETS. NE CONTR4CTOR SHALL PZEPA R OR REPLACE ALL DAMAGED :EILIN6 TILE ANC GRiC AS NECESSARY TC MATCH EXISTING ADJACENT JNO. PRIOR 'O INSTALLING ANY LIGHHT Fi,rTURES ON THIS Pi'ROJECT, THE CO TR.:470R ;S TO FIELD C.ECK FOR ANY CONFL'CTS WiT- E/'3 T''NG ME C•- IANICAL DUCT WORK E. ECTR :CAL CON✓UiT, FIRE SPRINKLERS PIPES, ETC-. AT EVER' L!G+- F -OCATiON AS SHHOILN ON THE REFLECTED CEILING PLAN. .F A CONFLICT E./ISIS, TrHE CON RAPTOR i5 TG kOTiFY M514 ,7F THE CCNFL IC; 3, °j0 A NEW LAYOUT CAN BE 'GENERATES NO LIGHT FI /TURE5 ARE 'G BE INSTALLED UNtT'L A.,L COf_ICT3 ARE RSOI_vED. THE CONTRACTOR S 44L.. PROVIDE EMERGENCY PATH-IUAY LIG.4TNCs PER CODE. Ti-E CONTRACTOR 6•.4LL PROVIDE AUDIBLE AND VISUAL ALARMS PER CODE. ALL LIG+`•TiPICs AND CONTROLS SHALL BE 9.+5 UNC. 11-IE CONTRACTOR 644AL L 6AT18F• THE LIGHTING SPECIFICATIONS BASED ON THE 4vAILAB_F ELECTRICAL vOLTAGE. CONTRACTOR 5 -41I COMPLY U2*I4 ALL AUTOMATED SHUT -OFF CONTROLS, SWiTCHING, ssENSoRiED SLLI!Tc.ES TIMED SHJ7C1 -E6, 4 C TESTING AND CO"M18810KING REQUIREMENTS. DOCUMENTS SHOW SCHEMATIC SWITCH LOCATION ONLY Al B/6 EXiT LIGHTS SHALL BE 'LED' STYLE AND LESS TEWN 5 NLATTI FIxT1RE UNO. SEE T?'E REFLECTED CEILING PLAN FOR LIGHTING CALCULATiONS. 171 CEILING NOTES zi ELECTRICAL/COMMUNICATIONS LEGEND 22 EXISTING ESA CEILING GRID • TILE. AREA OF ►+Etli CEILING GRID • TILE TO MATCH EXISTING D/6. EXISTING R/6 2' -0" • 4' -O" RECESSED FLUORE3SCNT LOW' FlxTUFE TO REMAIN C/1 RELOCATED WS 2'-O' x 4'-4111 'RECESSED RNORE3Cll4T LIGHT FRxTURE :-__ -J 1E MOWE'D/RELOCATED. ExISTINra 134 2'-11' • 4'-0' RECESSED FLUORESCENT LIGHT FIxTURE TO BE I-� RF1ovED • INS EXiT SIN (DIRECTIONAL WERE SHOYN) FASTING B1• 2'-O' • 2'-0' RE::SEED FLUORESCENT LIGHT FI/TUE TO E!F 6/8 LIGHT SWITCH. E E)ISTINts TO REMAIN. RELOCATED. N NEW. CEILING LEGEND vERT,C.41r. WIRE HANGER-NO. ,2 GAUGE • 41-0' OC. OR NO. JO GAUGE • 5' -0' O.C. ALONG EACH MAIN RUNNER. HEAVY GAUGE WIRE 'FIN'. ...---- VERTICAL STRUT FASTENED TO MAiN RU.'VEER AND CUT TIGHT TO STRUCTURE AEOvE, HELD IN PLACE BY AR7ICAL WIRE HANCsEQ AND HEAVY GAUGE WIRE PN. MAIN R,IJER AT 4' -0' O.C. ,t- 145' - VERTICAL STRUT = ASTENED TO MAIN RUNNER GR055 RUNNER TALLA'1QN INSTALL FER UNIFORM Bu'LDING CODE STANDARD 25 -2. 'METAL 5J3 ENS;: N SY'STEMS FOR .IC.OUaTCCAL TILE AND FOR LAY-IN PANEL CE �ING5' FASTEN PARTiTION WIND TO CEILING GRID GN WALL R LE66 11414 12'-0' AT COFR DOR DEMISING AND t30UW PARTI TIONS, PROVIDE 41••0, WIDE ACOUSTIC GATT INSULATION CENTERED OVER PARTITION ABOvf NIUNG CEILING. -- REVEAL (PANT BLACK) OR `HATCH E.' 1ST ING. Le' BLACK =04 /1 TAPE NOLO t5AGK ' /4' FRIOM EDGE OF TRRAC -- PROVIDE ACOUSTC BATT I1v3ULAT.ON f3ETILrEEN STUDS. 4' RUBBER STRA iGNT BASE • CARPE' 140N- Ca115. WD FILLER UNDER MAN %INNERS eEIBMIG BRACING PER DETAIL C. CONTINUOUS CEILING ARID - DO NOT CUT. LINE OF CEILING GRID BEYOND, SEE RCP. CONT. 7 1/1' • 1 V4' 26 GA. TRACK ki f (2) M0 SCREWS • 24' QC. r-- e/t' NON -COMB PLYWOOD DLOCKNG • WALL ►SUNG ITEMS (WHERE APPLICABLE - REFER TO DRf"l,JING PLANT) ALMIKNATE_5_ECN 151.9 20' WILE GALS. SHEET ME "AL • 440' FROm FLOOR TO BOTTOM (N LIEU of w00D BLOCKING) LIauI,_= 2 112' x 25 GA. JALV. STEEL STUD • 24' C.C. WITH 5/6' TYPE 'x' G E EACH 51DE PLAN VIEW V4' $/8' C•23 TYPE 'x' EACH SIDE, TYP. CONT. 2s GA GAO/. STEEL RUNNER CHANNEL - ANCHOR TO FLOOR AS REG'D. 4' RUBBER COW BASE • ve.T. BASE SECTION SCOPE OF WORK: TENMlT IMPROVEMENT CV AN !AWING CIPICE SPACE. WORK TO INCLUDE NEW PARTITIONS, OOP*, iREL i iiiit L JT FIXTHJRES, AND FINISHES. CONOTRUcTION rrigS: v-N. 6E RED AREA OF SUITE 1222 U6F OCCUPANCY: B ("Fla PROJECT DIRECTORY YGNITION 320 ANDOVER PARK EAST, SUITiJiTE 215 SEATTLE. WA 98188 20+6 -514 -5414 (PI-HONE 206-S53-3166 (FAx) E -MAIL - cYroods•ygnitiorzom FILE COPY 1 understand that the Plan Check approvals are subject to errors and omissions and approval of plans does not authorize the violation of any adopted code or ordinance Receipt of con- tractor's copy of approved plans acknowledged. IBJILDING Ml,1y,4Cs1' -1ENT: By'�n� IiIA5MNGTON REAL" F5'4TE +IOLCINGS bee UNIVERSiT'r STREET, SLATE :820 ate SEATTLE, ILA 981s!JI CONTACT: MARK BARRB'ER / � ,^N CsR�Q�E Permit No. 206 -613 -53'6 (PHONE, 206 -65 -530' ,FA /) E -MAIL - mberb!e• •walrolding• cc.- rgreene•wahpldInos,com 01" E"1AA R. MAR'/ N STEIN AND ASSOC., LLC 222! 5TH AVE. SEATTLE, WA5- iNGTC"N 9812! CONTACT: EiILL SIMPSON 206-441-1449 I 206- 44' -436i (FA') E -MAIL - bsirip•Crik•+ervInet.elrizo -+ oNTRA T A TO BE - ._TERf.-INED (1131"). • REVISIONS -'t . NO CHANGES SHAM BE w sz TO THE SCOPE OF a' -'; werr r f: , a!FROVAL CF TUXA. LA s',4 '. v' 3 C'». wit !E MA SILL MOMS A *VI PAN PUBt.'iPjIL L __ AND twin NC= Aool�oillLtPll I AIM adds CEILING BRACING NTS 9 CONTRACTOR SHALL i°ROVIDE ALL tUORK AND I"A'ERE ALS N ACCORDANCE WITH APFLIGAi9LE CfTY, COUNTY, STATE ANC FEDERAL BuLDING AND FIRE WOES COhTRAC *OR &+-MALL 3E GOvERNED SY ALL CONDITIONS AS INDICATE) IN THE CONTRACT DR4+WINCs9 1 5FEC IFICAT!ONS. CONTRACTOR 5*ALL VISIT JOB 3'TE AND SERIF` ALL FIEEC DIMENSIONS AND CONDITIONS AND NOTIFY r1t3g4 OF ANY DISCREPANCIES) BEFOI; PROCEEDING WiN WORK CONTRACTOR MALL OBTAIN ALL PEIQfwiTS AND AiPROvAL9. B/S INDiC:ATES 'ESJILDiNG STANDARD' AS 1ORoviDED BY LANDLORD AS DRA.,N AND /OAR SPECIFIED IN BUILDING CONTRACT DOCUMENTS. IF NOT SPECIF'E: . CONTRACTOR 9+4ALL SEE AD,ACEN' SPACES FOR E,iSTING E /•SMPLES AND CONDIT'Ci. . WALLS AND CEILING TO BE 'NDE°ENDENTLY 5U2r'ORTED FOR SE:SMIG CONDITIONS. ALL MECHANICAL, E-EGTR GAL, PLUMBING, FIRE ALAR" AND 5PR'JK`ER ANC SECURITY DESIGN SHALL of $2ERFO C) BY TINE DCNTRh.C'OF. AFL FURN 'URA •7ES.GN SHO.1.N CN PLANS S SCHEMATIC ONLY AND NOT IN CONTRACT, INO. TENANT'S TURN' TJRE /ENDOR 5►-4L_ >=1ELC VER!F•• PREMISE FOR LAYOUT GONFiGJRATIO' AND CLEARANCES ALL vIOICEVDATA AND CABLING DESIGN 54-Out ON PLANS IS 9C. E`1ATic CND" AND NOT IN CONTRACT. UNC. TENANT'S CABLING VENDOR 5••ALL VERIFY TENANTS REQUIiRL=MENTS AND PEW CONDITION$. THE CONTRACTOR PRCvIDE R XII.1 -M AS'4C' 2 COORDINATION AND SCHEDULING =0R T 4I5 PORT :ON OF '+iE WOW - NE Fo'LLOWINCs DRAI;1RdG5 ARE BASED ON ELEGIRoNIC UFORh'4'ION DERV FRr"1 A NUMBER OF SOURCES. ..4 -11_E DE.E''1ED RELIABLE, M5•4 C. ACT 8E HELD IESPC`$ISLE FOR 6FOR- ATiON =ROM OTHERS NOT FIELD VERIFIED OR W-.IGid HAS BEEN 4. T ERE5 Err OTHERS. THE CONTRACTOR S+•ALL COOINATE WIT++ TH4E 1SUILONCs MANAGEMENT r,N CONSTRUCTION H -ioUR? PROCEDURES AND MEN-005 ALLOWABLE M NI8 SOLVING. THERE SHALL BE 42' CLEAR SPACE N FRCNT OF THE PANEL SIDE OF vAV. BO>E9. IF LIGHTING LAYOUT CREATES A C3if CC,T, NOTIFY MStA PRIOR TO ANY INSTALLATION. THIS iS TO INSURE NO f 'V!S'ON5 WILL BE REQUIRED. CONTRACTOR '0 UPGRADE 51ESMiC BRACiG AS REQL 'RED AT EXISTING CEILING. CONTRACTOR -0 FIELD VIER'^' ALL ELEMENTS iNDICATED 45 EXISTING ON PLANS. NO FIELD vERIFic4-''oti .-.45 BEEN PERFORMED BY' r-5i4 STAFF. ',daze 1 NARDWARJ: SHALL BE RE..SED RELOCATED OR NEw BASED ON AVAP ABL''Y AND 6UfTABL iTY ALL HARDLIARE 31•4AI.L BE TENANT STANDAI MATCH £✓'STING COJDITIok.5 N SUiTE GENERAL NOTES b' UNLESS OTHERwiSE NOTED DOOR NUMBER TYPE OF DOOR A NEW ISIS 3' -0' WIDE SOLID CORE WOOD DOOR IN ig/5 FRAME. MATCH EXISTING. D. NEW 5/IS 20- MINUTE RATED 3' -0' WiDE SOLID CORE 11000 DOOR AND FRAME ASSEMBLY. 1.14TC44 ExISTINKs LIARDIME A 3/6 LATCH ET. b. 016 PASSAGE LOME' c. WS LODC6E T AND CLOSER XIS iiNG DOOR TO REMAIN tia?E$. 1. RE -Lr6E ExISTMG DOORS SCHEDULED FOR REMOVAL iNEREvE1F P0661BLE DOORS TO BE RE -USED ARE TO DE TOUCHED UP TO BRING INTO 'LICE NEW" C.GND?TION1 2. P'iROVIDE W.665F. Car. !JM1T HAR7411MRf 6. RE-KEY LOCKS FOR TENANT'S SECURITY. N.T.S. B/S TENANT INTERIOR/SOUND PARTITION NTS 10 PROJECT INFORMATION 4 9 BUILDING 2 1 SECOND FLOOR I AREA OF WORK] 141 AREA OF WORK - �--� -- SITE M N ERI BLVD. UPLAND '� R. MIDLAND DR. () SOUTHCENTER CORPORATE SQUARE BUILDING 2 565 ANDOVER PARK WEST TUKWILA. WASHINGTON 98188 SEPARATE PERMIT REQUIRED FOR gi MECHANICAL L ELECTRICAL PLUMBING GAS PIPING CITY OF TUKWILA BUILDING DIVISION 537° ' F" .. , .: 1 • Marvin Steih'sociates, LLC planning design 2V1 F?fth Avesir. Seattle. Washmiton 98121 MS 441 -1449 NTS 151 VICINITY MAP ITS CONTRACTOR 5 RESPONSIBLE FOR ALL NECE55AR` DENCLITIGN REGIJiRE: TO COMPLETE "NE waac AS DESCRIBED ON THE CONSTRUCT ON t.)0C.;JMI =TH'S. CONTR4c:TOR SHALL PROTECT ALL EXISTING FINISHES AND ASBE"IBLIES NOT BE''vG REMOVED OR ALTERED DURING C.ONSTRJ:TiON. CONTRACTOR SHALL PRCVIDE NEW Ff?A1INO AND FNISHES THAT ARE FLUSH. CONSISTENT AND IN ALiGPI1ENT WITH E. <ISTIivCs C.ONDiT!ONS. iN NE E•FNT OF FRA''/ING SIZE DMFERF'4CE5 'HE GGN TRACTOR SHALL FURR OR .ADJUST THE FRAMING AS RE 4,iii ' FOE: °RC°ER ALIGNMENT. CONTRACTOR SHALL YER'>1' KNINiJ1 FRAMING SIZE QEQLPRED FOR ELECTR'C4L MEGHAN!CA_ AND PLUMBING FEATURES BEING INSTAL._ED BY DESiGN/BUILD AND ADJUST THE si`�INCs AGCORD NIGLY. CONTRACTOR SHALL PATCH TC MATCH AND PREPARE: =0R r-P41gHi AT ALL LOCATIONS UJH•RE EXISTING ASSEMBLIES AR2 ADJACENT TO DEMOLISHE:. oR ALTERED AS8E*'BLiE• THE SCOPE OF WORK 'SHALL INCLUDE BOTH SIDES OF ALL NEW ASSEMBLIES DEFIC''ED ON THE DRAWINGS EvEN L'i•EN LOCATED iN AN ADJACENT LEASE SPACE. NC PART OF NE .6ORa'!' C 15 'O BE LEFT JJNF!N15HED uNO. 0-4,4/s4GES TO SPEC!FIC.4 1 S CAN BE MADE !F APFR: .2vED B` ^'ASIA, THE BU LDINdG MANAGEMENT AND NE TENANT CONTRACTOR :MALL SUPPLY ALL REQUIRED JINGTION 60xES, COVERS AND ACCESS DOORS AS NECESSAR'r VERIFY SUi..DING STANDA!R>r 5. CONTRACTOR SHALL COIF!Ri ' 1'PE AND LOCATION OF FIRE ExTANGU18HE1 AND /OR cA8I ET8 WIN T-E GOVERNING FIRE *"AR30-44 . 13EFO 'NSTAL:.ATIOPL IF NOT SPECIFIED ON DRAJLINGS, CONTRIC:TOR St -HALL PROVIDE THE MINIMUM NUMBER :?F WALL MOUNTED FiRE EXTINGUISHERS REMIRED BT CODE. 19I CONSTRUCTION NOTES J EXISTING SHELL AND CORE. EASING B/e 1 HOUR RATED CORRIDOR PARTITION. Ei19TINJG 13/5 TENANT INTERIOR PARTITION TO REMAIN. EXISTING ewe RE'_ TE. PULL HIT. IN B/6 WOOD FRAME WITH SAFETY GLA6e. E,;STING CON5TR;CTION TO BE DEMOLISHED. NEW B/S TENANT INTERIOR PART'rION: 2 YI' PETAL STUDS WITH 3(8' GLES EACH SIDE FROM Fi..00R TO +UNDERSIDE OF NILNG CEILING. SEE DETAIL 9/11-1. NEW B/9 TENANT 60166 PARTITION: 2 t/' METAL STUDS • 24' O.C. URTH b/Y CAB EACH SIDE FROM FLOOR TO UNDERSIDE OF HONG CEILING. PROv1DE ACOUeTiC EATT INSULATION 114 WALL CAVITIES CONT., 4 4' -0' WI•E ACOU&TiC BAIT INSULATION CENTERED OVER PARTITION ABOVE H4,640 CEILING. SEE DETAIL •/TI -I. } N Ali that certain real prooer-, sitlrated in Cie City of Tukwwi'a, County of Kin_ State of i.iasningqton, be.r;. a portion of the east I/2 of the rortruest 1/4 or the southeast I/4 cf "Sec. 26, 1 LPN, RAE JJM., ano be,ng more pa- ticu.arly described as follows: BEGI *1NiNG at the intersection of the ne-ther:- he of said Southeast 1/4 with trle westerly maroin Of Arc, Jver Park West l .4` /°,.rue SOU -.r', distant along sa1Q rortnerly line NE3.8705'42'Li1 ;369.34 Feet Crom tf• northwest CGrner of said south- east quarter * - thence from &aid POINT EC NNING aiord &aid jest sr marg,r 60174 "''29'W 451.30 rat. thrice 'saving said wester: y mars r tancert to fre :edino course alone tre arc or a ..;,rve to the r gr» Kavin raoius or 521.0© eet and -a certrai snare c ' 90706'4°_'. an arc lerctr c; '1864I t to a paint o' a line that is parallel To a ";t 501.40 Souther: of tv,e norther tine or said boutreast :.'4t thence a ona said parai e'. line \88 ?©542'; iSC9 30 feet to e point on a line that le oa + +e'�.uitn and 26100 feet wester) of the sass line said east 1/2= thence along ;as: said paraiie: �+ne Nei74 "'29'E :6 feat to a oo!rt on a lire of :5 parale' to and 365.40 Meet souther of the nortre line of Said soutreast 1 /4t thence along last said paraiiei ,ire S881cs4. E 3 -50 ✓set to a point on a sire that •e parallel 'to aro 2235'0 feet waste - of the east Tine o said east i,2t tner:.e a 'one last said pare:iel Tine P.0174-.9'E 100.00 feet tr a po rt on a line that is parallel to and 265.4© leer southeriy of the northerly I ne of said southeast 1/4t therce 8 lOng last said parallel line Ne8 ?05'42'U1J12.5E' feet to a point or a line that :e 1o8ralle to and 236.00 feet wester 'y ---f the east line of sand east l2t thence alona It said oara,le: ins N01 141129'= 26540 feet to a point on the nortrerlyy Arne of said southeast 1/4± then ce a one said norther IL line sae 20s '42T 206.00 feet to the POINT iF BEGiNNiNC-s and ecntainine 2.406 acres of taro more or !ass. 4D01 55: 565 ANDOVER '"'ARK WEST TUKWILA , WA. we. LEGAL DESCRIPTION NEW 5/9 REL ITE: PULL M. P4 0/6 WOOD FRAME WITH SAFETY GLAe6 WERE RG U F?) - BUT" JOINT TYPICAL d,e FiR EXINGU16HER CAISINET. SYSTEM RUR AIRS SUPPLIED AND INSTALLED BY MOT. CADLtNG DY TENANT. COLD WATER Liit ALIGN CORE DR :.L. COORDINATE LOCATION WTN TEN/NT'6 FURNITURE VEAPOR VERIFY CDSTIRLCTIONS PRIOR '0 DRILLING. TI -I COVER SNEE' TI -2 DEMOLITION PLAN T1 -3 CONSTRICT ION PLAN TI -4 REFLECTED :EILING PLAN TI -5 ELECTR+CAL / CCMI UNICATICKS PLANS 23 DOOR SCHEDULE 24 CONSTRUCTION LEGEND 25 H1pl•Rr dr: NG 406 99135.023 CHECKED BY: WJS DATE: 05/05104 PERMIT SET scA( F- AS NOTED REVISIONS INDICATED THUS L, DATE o ff- TENANT: oo/ -,Beg YGNITION to'4- t49 DRAWING INDEX • .6 V SHEET TiTIE: fIttilvfo CITY OF Tutiavim NAY 0 5 2004 errm COVER SHEET :PRtODUCTION, ALIERAPON OR PUREICAAQI OF THIS TI-1 lA 11DIG, �RIOUT MIMED PERIIAS91 * 9Y WS*A, B MCLADON OF FEDERAL CCPIIIIINT L** cOPYRIPIT r 111SNA 2004. OF 5 • 4' • 1$ • (T) rr li 11 11 11 1l 11 ft 11 11 11 11 11 —11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 -1r 1r I I I I I I I i I I 11 11 11 11 11 11 ir 11 REFER 11 LONC/TPJCTION PLAN .1 FOR 7.:;MENSICN. TYP. 8, o i DEMO EXISING 1 o COPPER PIPE iff 1 f'0681E5LE. N/ERIP•K 1 1 LFUNCANZ;LCNCRr1 VEIF R''r W/ I i PIOCIFICA' ON CON.S116TO I ONE OR 0 I TR,IN6CT!ON: ... I RELOCOVION IS DE PL"'0N/E7_.' TYP. 1 i APFROPR 4TE. \I i i -rr 11 :1 11 11 11 11 11 REFER TO CONETRXTION PLAN FOR DIMEN1510N, TYP EXISTIP.6 11 C.OkSTRUC-11CN TO 11 E3E 1..1EMOvED, Tro r...., ..„---. i r....., ..„.....• 1 1 . / 1 I 1 ‘ / I 1 1 ■ 1 1 I 1 I I. ii v 18 • Y ' L. .1 t JL_I a • 11 11 11. _ 11 1 1 11 11 11 11 11 11 limemeseimon 11 11 11 11 11 11 11 11 11 11 11 11 -71 1 11 131 II r? maul II 11 11 11 II 11 11 11 II 11 11 II 11 11 II 11 II 11 11 of 11 11 11 11 ti 11 11 11 11 111 II II 11 II 11 II 11 11 11 11 II 11 11 II 11 II 11 11 11 II II 11 11 11 11 11 II 11 11 11 11 11 II II 11 II 11 II 11 11 I II Lt"------....-----.-----...4.1 SECOND FLOOR PLAN 4) 1/8" V-011 NORTH 0 5' 10' 20' 30' roillier. 1 SOUTHCENTER CORPORATE SQUARE BUILDING 2 565 ANDOVER PARK WEST TUKWILA. WASHINGTON 98188 Marvin Ste kssociates, tic planning des ign 2221 Fifth Avenue, Seattle. Washington 96 121 (206) 44! 449 N LflAl Ls). M C,G ouB Nu . 99135.023 CHEMED BY: WJS DATE: 05105/04 PERMIT SET SCALE: 1/8' = 1 '— rum-In/NS iJuit1,48.,c... . REVISIONS INDICATED THUS P DATE TENANT: YGNITION 41)04-14y SHEET TITLE: _fitecenco urrY OF TUVI.A MAY 0 5 2004 Polka c ./ITEA SECOND FLOOR DEMOLITION PLAN EPRO01001014, OtitRAKS• f'UdUCAF1101 Of INS RAVING, VIMIOUT 1iPIESSE0 PERMOSION BY IIS&A. 6 VIOLATION OF FECCRAL OOPIIIIONT LA41. COPVIKBIT Y 2004. TI-2 OF ETD EQ. L_ -4 REcErTIO OORACiLCOFY UJL !I 1 S'-e• i . N (y2trif EXIST. COLUMN. EXIST (ALUM. UM 1•1111 Ill r 1 • : •! EXIST 1 COLuMN.- --1.-- IMO 111 r 1 r 1 "11 r• •U1111 VIM • fI 1 r 1 r r 1 1 al r 1 1 r 1 : • IHF•••-••••,1111.1 t r 1 r 1 r 711014-111110 CONSTRUCTION NOTES: CONTRACTOR TO vier' SITE AND vERIF■- ExISTNG CONVTION6 THAT MAY AFFECT THEIR WOW PR;oR TO PREPARINCs CCNSTRICTICN COST ESTPIATE. 2. ALL wALL FILLS TO ALIGN 'JAN ADJACEW SLPFACEE. C/4 EACH SIDE 3. INEMOvAL OF PREvIOU6 TENANT'S ARTWORKS LEFT was oN EAIST. PAWrICN03. PATCH MC IP4i61.4 A6 REQuilRED 4. TENANT INTE:ND6 TO INSTALL 1, CARD READER SYSTEM AT TENANT Drew. cooccvmArE WIT', GENERA,. CONTRACTOR AND OMER FOR SYSTEM SPECIFicA71041. ft • wflI CF,_ AREA CONSTRUCTION KEYNOTES: Ex iST1NG CAEEwORK AND $p TO ‘ETeAIN. 0 ALIGN PART TION • CORNER 0 NEW 3C' DEEP PLAM COWER • 36' AFF. UR1W 4' W614 5ACKSPLA8+4. C4 ISELCUI. PRc VIDE 13/5 F21.4:41 5l:PCsOfre 45 REQUIPM. 0 NEW 30' DEEP SA IPLAr COLNIER • V' AFF. WIT14 4'14IGN SACKSPLA614. OPEN BELOW PRov1DE EVS PLAT*, 5uPPCRT5 AS REWIRM PROVIDE GROMMETS AS RE(24,REID Ci) REWORCE PARTITION FOR MOUNTING OF PLASM SCREEN& 0 IF NOT ALREADY W, UPGRADE -4ARDLJARE CF EAST DX TO di'S LOCKSET. 0 PRCYIDE RJRCNC• IF REWIRED FOR ELECRICAL 1 VOICE/DATA OIrTLETS. SIGN TO BE PLACE NEXT TO DOOR READ - DOOR TO OE OPEN WRING BUSINESS WCURS' DOOR 504AU. E LOCKED DiANG CFF •OURE. iukEN SCUTI4 AREA 16 VACANT LOCK NALL ALL011 EGRESS talsAIRDS Exit. ® NEMOvt RANK FACE PLATE • 60' AFF. 'DAMN AND MON WALL AA REWIRED. • • 1 214 aFFICI SECOND FLOOR PLAN 1/8" =1.-0" NORTH 0 10. 20' 30' -•••••••••• • V SOUTHCENTER CORPORATE SQUARE BUILDING 2 565 ANDOVER PARK WEST TUKWILA. WASHINGTON 98188 ,. 587C REGIS - .E -CF. . *, C., 4S-# WILL, -- sTATE • . W : -.• Marvin Ste, -ssociates, LLC Manning ' design 2221 Fifth Avenue. Seattle, Washington 96121 (MS 441 1449 utif1/40111 Ls r. MC,NG •uti M:,.; 99135.023 CHECKED BY: WJS DATE 05J05/04 PERMIT SET SCALE: 1/8- . kL.,..As ..:...,Ai. . ,. . REVISIONS INDICATED THUS DATE TENANT: YG IT104. DO 117 ralli."..-6:14„,,, SHEET WU: MAY 0 5 zgo4 PINAR CIINTEN SECOND FLOOR CONSTRUCTION PLAN [PRODUCTION, PUPATION OR PUBUC.ARON OF MIS Now "man MIMEO PONSISSION BY MS111A. IS VIOLATION Of ROM COPTIVONT ILA*. OOP Y MA 2004. 11-3 Of 6 4 fLL.;.: 746- 1 an J . v •1 C? C7 + rr rN > I- 0 rr 4; "Lc K' ;. E E Q' a CEILING NOTES: LIGHTING CALCULATIONS: 1. RE- CIRCUIT SWI1GN■5 OF EXISTING LIC +TMG 45 NECESSARY TO AREA OF WORK = S,212 aJF COI"IF'LY WITH NEW LIGHTING LAYOUT. 2. 01°EN OFFICE AIREA'221 TO BE SEPARATELY 9WTCHE;. CEILING KEYNOTES: SUITE MASTER LIGHT 9WTCi4 veer,- LOCATION RE-CIRCUIT TO ACCOMMODATE NEW SUITE ARRANGEMENT . (`) REMOvE EXIST. LIGHT SW CHES. PATCH AND MOH AS NECESSARY TO MATCH ADJACENT. (� IETIOYE EXIST. CEILING- MOUNTED ELECTRICAL OUTLET REPLACE CEILMG TILE TO MATCH E>..Irr. WATTAGE ALLOW; 5222 SF x i2 WATTSbBF = 11066.4 WATTS WATTAGE 1ORO'VIDED: (109) 2x41�pJ, RELOCATED 4 EXISTING L&IT FIxTuRES x I00 LIATTS/FIXTURE = 10.900 WATTS OttirlARY WATTAGE PROVIDED 15 LESS 'SAN WATTAGE ALLOWED. SECOND FLOOR PLAN ,re� =ro � ) NORTH v. kO 4k p4 610 SOUTHCENTER CORPORATE SQUARE BUILDING 2 565 ANDOVER PARK WEST TUKWILA. WASHINGTON 98188 Marvin SteitiAssociates, tic P tannin 8 design 2711 Fifth Avenue, Seattle, Washington 98121 (206) 441-1443 udrl sea 04. MC,NG ,ti,d NL.: 99135.023 CHECKED BY: WJS DATE: 05/05104 PERMIT SET SCALE: 1 /8" = 1'— RtY1J11JiV 13SuAN REVISIONS INDICATED THUS DATE • TENANT: YGNITION MAY 0 5 zoo nay.*.. low SECOND FLOOR REFLECTED CEILING PLAN :PROOU AOh, AILFERA IKIN UR r''USLICA IION OF FMS UMW, IS1NWT DRESSED PERMISSION BY NSitA, Q VIO1A1ION OF FEDERK 00101111NO LW COPIIIIGHT r 111514 2004. TI -4 Ji 5 ALA., .L:.1...4.wr • ns '� 4 '1 iL ELEv. L21$ 20A AFF. 4 AFF 20A =IN . • - Sim MIR 1 =I ?DA 2 CIRCUITS- • (1) vERP' IRE21I14:1•ENTS TENANT 15 CABLES (CAT 5) 6-) CIRCJITS vERPY REGJIREMENTS 11,1%4 TENANT - • 2 CIRO; E E 6 L-Ne 2 CIRCJITS 2 CIRCUT9 V 1 1 1 ✓ T --'—,1 r 1- • '1 r ia■ i um !s , aMmir - IMMI i ■ s I 1 1 .1 1 • 1 I I i ✓ — --4 — •— • "ii r --4-- — r ill r OM ■ alliorm-Ifylis t MIMI I "Il r 1 i 1 .1 • 1 I 1 1 r _ . —4— — 1 r —4- -- — , ---1 . _......±11111111 a= I , I I 1 1 1 1 1 1 i 1 ✓ —4— : — ... r — : : i — -.1 : s I 1 ✓ ---f- - — -, r il ■ • `64 E DE EA E ' AFF. E I -441 WEI E • .46' AFF ...a. • • 4 • 2 CIRCUITS : 1••11 SIM : 1 3 CINCJIITS-, L ELECTRICAL / COMMUNICATIONS NOTE: ELECTRICAL / COMMUNICATIONS KEYNOTES: t COW LocaTioNs ARE TO ISE .soccrAhlEv SY GENERAL CANTRACTOR ELECTRCAL CalTRACTOR AM FURNITURE /ODOR a, v , 1 EkISTIM U MOLD FROM CEILING. VER g` WIN TENANT ILNETHER -0 DEMO OR RE45E. 2 CPEN J-BOX PRCIIDE COWR PL.ATE AS NECESSAW, 0 EXISTING tUALL-MOLNTES IDO4AUST FAN 0 SPECIAL WYK N SERvER Rom! 02'9. TO 8 E PRC v.DW BY LANDLORD • MONT'S EXPENSE SPAT CNS ARE TO SE COO1CNATEr. ISETILEEN TENANT MG LANDL.GCD ® PRIC\VE JUPC110N Box IN CE1LM FOR 111.41t1A SCREWS VERIF`' SPECIFICATIONS AND RECUR:PIE-Nig IAN TENANT (6) ELECTRICIAN TO COORDINATE LOCATION UM TENANT TENANT'S CAME Ca4SULTANT TO WALL FNIE4ED - OUTLETS AT 4CRK m.o., • • , 6 " = SECOND FLOOR PLAN 4 1/131%0" ) NORTH 0 5' 10 20' 30' NM IN NI Si SOUTHCENTER CORPORATE SQUARE BUILDING 2 565 ANDOVER PARK WEST TUKWILA. WASHINGTON 98188 Marvin Ste4 Associates, LLC plan n ing design 2221 Fifth Avenue. Seattle, Washireton 98121 WV 441 -1449 iiltAtok 61: MC,NG A-Ai NU.: 99135.023 CHECKED BY: WJS DATE: 05/05/04 PERMIT SET SCALP ye = 1.- ktviuusi REVISIONS INDICATED THUS DATE TENANT: YGNITION SECOND FLOOR POWER/COMMUNICATION PLAN Lraftuoucrturt ITRA now uR PulluCATION OF MI5 MIK 111114OUT EAPRESSED PEINESSIOI1 fly MIA, VOLATION Cf FOWL OOPIIIIGNT LAN. COP111101I rvs 2001 4 TI-5 OF 5 1