Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D04-206 - SOUTHCENTER MALL - CACHE - TENANT IMPROVEMENT
CACHE 711 SOUTHCENTER MALL D04-206 1 z -J 00 0 • 0 W W V) ui O. 2 g u. < ci w Z ' C) Z •11.1 2 :) c) ,c) a c) 0 I— • La .7C Y6 ▪ ;Eui 0 �g City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 DEVELOPMENT PERMIT Parcel No.: 2623049004 Permit Number: D04-206 Address: 711 SOUTHCENTER MALL TUKW Issue Date: 07/19/2004 Suite No: Permit Expires On: 01/15/2005 Tenant: Name: CACHE Address: 711 SOUTHCENTER MALL, TUKWILA WA Owner: Name: 7G SOUTHCENTER LTD Phone: Address: 25425 CENTER RIDGE RD, CLEVELAND OH 1 Contact Person: Name: CHRIS MCCOMAS Phone: 310- 328 -6300 X 104 Address: EXPRESS PERMITS, 1327 POST AV, #H i Contractor: I Name: HANNA DESIGN GROUP INC Phone: Address: 4301 WILMETTE AVE, ROLLING MEADOWS IL Contractor License No: HANNADG969LD Expiration Date: 06 /04/2006 DESCRIPTION OF WORK: COMMERCIAL INTERIOR ALTERATIONS TO INCLUDE: DEMOLITION OF PARTITIONS, DOOR, FLOOR FINISHES, SHELVING UNITS, ETC.; INSTALLATION OF NEW PARTITIONS, DOORS, FIXTURES, FLOORING, ELECTRICAL MODIFICATIONS AND LIGHTING. Value of Construction: $40,750.00 Fees Collected: $916.70 Type of Fire Protection: SPRINKLERS /AFA Uniform Building Code Edition: 1997 Type of Construction: IIN Occupancy per UBC: 0023 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: N Hauling: N Start Time: End Time: Land Altering: N Volumes: Cut 0 C.Y. Fill 0 c.y. Landscape Irrigation: N Moving Oversize Load: N Start Time: End Time: Sanitary Side Sewer: N Sewer Main Extension: N Private: Public: Storm Drainage: N Street Use: N Profit: N Non - Profit: N Water Main Extension: N Private: Public: Water Meter: N doc: Devperm D04-206 Printed: 07-19-2004 `Qtiis: 3 .. J , U , ,:` y �. •µ y !�:• . •. u ��� ti. •i :h£•c. �.' .. it. •��+{;( '�b'h+r'�,5.. .•�. :.t '•s�?•'� +`7.w i�� =ui.im4. it�u C.. bp�r']. AY: i. kG}:+` u` �4 +tuG.:1w`�.1.:ia6kda'.:an:.:nw z ~ w � D 00 CO 0 W w LLQ co D = f _w z w 2-1 0 =) C3 ON 0H wW LL O W Z UN F- = O ~' Z effte Cit of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Permit Center Authorized Signature: Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit. Signature: ` :�> Date: Print Name: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: Devperm D04 -206 Printed: 07 -19 -2004 Z ~w W U. UO CO CO W W O LL ¢ cf) = �W Z f- H O Z F— W W U� 0 - o E- WW U- O W Z U CO) O ~. Z �� City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 PERMIT CONDITIONS Parcel No.: 2623049004 Permit Number D04 -206 z z Address: 711 SOUTHCENTER MALL TUKW Status: ISSUED Suite No: Applied Date: 06/21/2004 Tenant: CACHE Issue Date: 07/19/2004 v v 0 � o � 1: ** *FIRE DEPARTMENT CONDITIONS * ** CO W w 2: The attached set of plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: J 3: Maintain fire extinguisher coverage throughout. U Q = a 4: Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5) �w z F F- 0 5: Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors w w shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 1207.3) v co 0— 6: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle w W is engaged from inside the tenant space. (UFC 1207.3) U U- 0 7: Exit hardware and marking shall meet the requirements of the Uniform Fire Code. (UFC 1207 -1212) z W U� 8: Internally illuminated exit signs shall have both bulbs working at all times. (UBC 1003.2.8.4) z 9: Maintian sprinkler coverage per N.F.P.A. 13. Addition /relocation of walls, closets or partitions may require relocating and /or adding sprinkler heads. 10: Sprinkler protection shall be extended to all areas where required, including all enclosed areas, below obstructions and under overhangs greater than four feet wide. (NFPA 13 -4- 5.5.3.1) 11: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recorgnized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1901) 12: Contact the Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1900 and #1901) 13: All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 14: Required fire resistive construction, including occupancy separations, area separation walls, exterior walls due to location on property, fire resistive requirements based on type of construction, draft stop partitions and roof coverings shall be maintained as specified in the Building Code and Fire Code and shall be properly repaired, restored or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (UFC 1111.1) 15: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed doc: Conditions D04 -206 Printed: 07 -19 -2004 mo.`s - Dais;> GY ,ivui�iI ; � «i#' "fawctrc'fJ.sktii y k g City of Tukwila f908 Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 description of intended use. 16: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 17: These plans were reviewed by Inspector 512. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. * *continued on next page ** i j i M I doc: Conditions D04 -206 Printed: 07 -19 -2004 Z �z '~ w JU UO ND W = H CO LL wO �a CO a =w �_ Z 11- O. Z r- w w U O N W H 0. U. O .. Z W U CO O H- Z .-- t ti �g City of Tukwila { 19C8 1 i Department of Community Development / 6300 Southcenter Bt_, Suite 1001 Tukwila, WA 98188 / (206) 431 -3670 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: I M Date: C� doc: Conditions D04 -206 Printed: 07 -19 -2004 Z oC 2 u� D UO N NW NLL w �-i U- U) d. = W z� r- o z Ir- UJ �o U O U' O F-' W U, t=- U u. O . -Z W N U= z CITY OF TUKWILA � Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" Suite Number: 'Lo !E Floor: Name: _o,-r. S A-A C_ cT y r� -2 Day Telephone; Mailing Address: 21 Pu S r f y+ V c a / ( G,•, Cam- (A y j U City State Zip E -Mail Address: ( c'r S nA 0— Gk P rLe" 12�K (— - Fax Number: Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: **An original or notarized copy of current Washington State Contractor License must be presented at the time of pen issuance* Company Name: 1) e_^ n % , A. r ( Mailing Address: 0 , 'w . 1 - 20 1 - 0 ' 6 - 76 o t City State Zip Contact Person: & c 2 Day Telephone: 4im# � j l 7.fb S - Zit!;_ E -Mail Address:_ -. --- Fax Number: 0 V7 I Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: VpplicationApertnit application (7.2007) 7/2007 Page l .5+.1. °i ' k�L':..`.' i".: 1: L��'',` f':'', f�,'' R??.'!^.?: a.' m. y.. a2yxxnw,:. va.+!<,.,.. .w.,�,•maHr�rtn.:e+murn.wr,M*ry ,r• ....,�.... King Co Assessor's Tax No.: ZG _— S O !f o f y v4- Z Q ~ w � JU UO CO 0 W = F-- �LL WO J U_ = W H = Z E.. F_ O Z F_ W W U� ON o F- W W LLF- �" O w Z U= o H- Z Property Owners Name: L..) c..S +4, Q.0 ( "re Mailing Address: i 1.4 I ( (,f i� P T3 l.. r(� L. A , �+a U 0 ZS _ l City State Zip i{j,l �'j/� ' •+ n .Rif .IyL'., a �, � If#t �wti�� . ,:� i�*��^aStYaE % _• , r -f.,. " - Valuation of Project (contractor's bid price): � t (] Existing Building Valuation: $ Scope of Work (please provide detailed information): t ` v M r ,,. , � C 1!'4A ( ; � � 1; �A l ��, - f -,'v.� D-t 0 1 - , n r rl o r) i �1 fir, i �, •n i t ,..P r Will there be new rack storage? [] ..Yes M.. No If "yes ", see Handout No, for requirements. t t. Prd ide'All Build ng.Areas in Square Footage.&low PLANNING DIVISION: Single - family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: r j `,- Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling:____ *Provide documentotion that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: M A Handicap: Will there be a change in use? [] ....Yes No If "yes ", explain: FIRE PR TECTION/HAZARDOUS MATERIALS: S z d CAYO - Z eC - r Sprinklers []..Automatic Fire Alarm` ❑.,None E] . Other (specify) t 4 prkl . Will there be storage or use of flammable, combustible or hazardous materials in the building? F .. Yes , No If "yes ", attach list of materials and storage locations on a separate 8 -112 x 11 paper indicating quantities and Material Safety Data Sheets. 4pplimion34mmit sppliution (7.2007) ]1200) Page 2 Z �Z W QQ� J UO Cl) CO W w U. N� = �W ' ZH Z� G U� ON OF W H u' O LJ I Z U= O f- Z ' ,..a..o, .Mr ea . t � •r:i no- :.l +.(x "° iFr1+ +4' iL� 1:¢Ar° :•, h •� .r li'• • .'•. .0 'ie {..v: Addition to' (T e bf Type of Interior Exis in& : Construction Occupancy per Etstin (N. '.Remoel Struc New UBC : :; pecUBC: Ylbor 2 Floor: ' 3 Floor Fl oors.'. `: •.:•: ;;,:,' y' Basement. •441„w`::4•�!:ul,,;,.r Accessory, Structute!,' DetachedGaragc° ' Attached Covered. Ddck Uncovered Deck PLANNING DIVISION: Single - family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: r j `,- Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling:____ *Provide documentotion that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: M A Handicap: Will there be a change in use? [] ....Yes No If "yes ", explain: FIRE PR TECTION/HAZARDOUS MATERIALS: S z d CAYO - Z eC - r Sprinklers []..Automatic Fire Alarm` ❑.,None E] . Other (specify) t 4 prkl . Will there be storage or use of flammable, combustible or hazardous materials in the building? F .. Yes , No If "yes ", attach list of materials and storage locations on a separate 8 -112 x 11 paper indicating quantities and Material Safety Data Sheets. 4pplimion34mmit sppliution (7.2007) ]1200) Page 2 Z �Z W QQ� J UO Cl) CO W w U. N� = �W ' ZH Z� G U� ON OF W H u' O LJ I Z U= O f- Z ' ,..a..o, .Mr ea . t � •r:i no- :.l +.(x "° iFr1+ +4' iL� 1:¢Ar° :•, h •� .r li'• • .'•. .0 'ie {..v: K li {t � MECHANICAL CONTRACTOR INFORMATION Comppny Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: '"An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance* Valuation of Project (contractor's bid price):' $ Scope of Work (j)lease provide detailed Information): Use: Residential:. New .... F] Replacement ....❑ Commercial: New .... ❑ Replacement .... Fuel Type Electric ..... ❑ Gas .... ❑ Other: Indicate type of mechanical work being installed and the quantity below: i • j j� n . .Lp . a 1� + i t ti y (��.�/ T.�� n ��!! ([+,�'11(nryry�� �}I�n�;Y'�5� Fumace<100K BTU Air Handling Unit Other Mechanical 0 -3 HP /100,000 BTU >-10,000 CFM Equipment Furnace>100K BTU Evaporator Cooler 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Ventilation System 30 -50 HP /1,750,000 BTU Mounted Heater Appliance Vent Hood 50+ HP /1,750,000 BTU Hcat/Refrig/Cooling Incinerator - Domestic System Air Handling Unit Incinerator - Comm/Ind <- 10,000 CFM Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the UniforidBuilding Code (current edition). No application shall be extended more than once. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOIE THIS PERMIT. Signature: BUILDING OWNER OR AUTHORIZED AGENT: Date: 6 1 Print Name: (I +t- L-4. v 1_ 7 Day Telephone: 3 (o 11-w (, 3 0 y Mailing Address: c, S4 a-e `C O- r C_ ^ eP__ cal 9JU S0 I City state Zip Date Application Accepted Date Application Expires: Staff Initials: /� 6/ � L / -d 1z -�1 Ste' UMiutimu\pamit application (1.2007) 7/100 Page 4 ' .... - e �'�. .;: t��?. �, z' ��'' �q�t' t. r�+'•. �` �. i. f; M�', t' M• XniAY�+ t�H1e' IG* �` G*! s:V! kM+ AmNY*. 42" r't+ 11% �& m�+; xco-enn�.' �M• v tiry :�nrw..k.+.r.<.«..»r...... >.. s iira...c,�. ,.,.i .. ....:. .: .. ..: .•...,.,..._: !a ...9.,.+..x +� « t r.. w .ad....d'w..:..w...�•:.r,�t�.wn .. .. • I' Z ~ w D � JU 00 0 J = F- C/) L w UQ i .. w Z Z� w LLI U 0� 0 !— w HF- LL O W Z U= I— O Z City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 i RECEIPT Parcel No.: 2623049004 Permit Number D04-206 Address: 711 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 06/21/2004 Applicant: CACHE Issue Date: Receipt No.: R04 -00906 Payment Amount: 557.35 Initials: SKS Payment Date: 07/19/2004 01:47 PM User ID: 1165 Balance: $0.00 Payee: HANNA DESIGN GROUP, INC. TRANSACTION LIST: Type Method Description Amount ---- - - - - -- -- - - - - -- --------------------- - - - - -- ------ - - - - -- Payment Check 26206 557.35 ACCOUNT ITEM LIST: Description Account Code Current Pmts ------------------------ - - - - -- ---------- - - - - -- ------ - - - - -- BUILDING - NONRES 000/322.100 552.85 STATE BUILDING SURCHARGE 000/386.904 4.50 Total: 557.35 Z W. ar � JU 00 CO) J H T) LL w J U- � �w Z = H t— O Z F-. L W 0p U ON a WW ~ 1= ll. O u1 Z. U =. O Z City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 RECEIPT i Parcel No.: 2623049004 Address: 711 SOUTHCENTER MALL TUKW Suite No: Applicant: CACHE Permit Number Status: Applied Date: Issue Date: D04-206 PENDING 06/21/2004 Receipt No.: R04 -00752 Payment Amount: 359.35 Initials: SKS Payment Date: 06/21/2004 01:57 PM User ID: 1165 I Balance: $557.35 Payee: EXPRESS PERMITS I TRANSACTION LIST: Type Method Description Amount Payment Check 24368 359.35 ACCOUNT ITEM LIST: Description Account Code Current Pmts ' ------------------------ - - - - -- ---------- - - - - -- ------ - - - - -- PLAN CHECK - NONRES 000/345.830 359.35 Total: 359.35 z 5 C.) UO N a C0 W J = Cf)w w J a = w z� E- O z F- w U� O N a F- W L O z W U co) H =. O Z INSPECTION RECORD detain a copy with permit 4 - :2 0 INSPECTION NO. j0& 6)431-3670 CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Projec � Type of aspection: Address: f� ` f I Sl5ecial Date Called: -- G? — Instructions: > Date Wan d: a.m. p.m. Requestgr. ' Pho> Pho a No: pproved per applicable codes COMMENTS: r�i2Fi/F 6, Corrections required prior to approval. Cho, -,, /cam l�1 To i rv,4 l iftRector: ! Date: -.3/- o 7.00 REINSPECTION FEE . EQUIRE Prior to inspection, fee must be ail at 6300 Southcenter B d., Suite 100. Call to schedule reinspection. RecelOt No.: I Date: Z i� Z W QQ � JU UO N U) LLJ J = NU_ WO �� LL < co d = W H = ? F- H O Z l_ W W U� O - o t-_ Ww LL 111 Z co O F... Z ___.:._,..--- INSPECTION RECORD Retain a copy with permit S IN7ECT IO NO. PER IT CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (20 )431 -3670 Pro' t: " jl-ju Type of Insp Etion: M li $0 Ad re / ss: �, Date Called: Special Instructions: Date Wanted: - a.m. p.m. Requester: - Pho o; Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: Date: n $47.00 REINSPECTIO$ FEE REQUIRED. Prior to inspection, fee mdst be Receipt No.: '; Date: r Z �Z '~ W OC � JU 00 W = ILL W LL �d = W f- Z� H O W �5 U� O N. OH WW HL) LL CO) O� Z INSPECTION RECORD t z Retain a copy with permit b L- o& INSPECTION NO. PER I CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 '`FZApproved per applicable codes. Project: 01 N6 3 Type of Inspection: �' tia, '0 ��✓a� Address: "7I 1 s• n• m A! Date Calle : c am; - 2- s -o y Special Instructions: Date Wan a.m. 9 - Z (- e L/ p.m. Requester: iz Phone No: Z Z �W QQ� JU 0 N U) LILI J H S2 U- w UQ c o =w F- _ Z�— l— O Z�— w w U� co WW H F U- - �Z 111 U= O Z Corrections required prior to approval. t 1 INSPECTION RECORD Q � Retain a copy with permit p INSPECTION NO. PERM O CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: T A 0 Type of Inspection: C LA' Address: Date Called: 7 1 1 , C'• 1 st U— Z� Special Instructions: Date Wanted: m. V m. Requester4. P, � e !L Phone No: 70 - 5/ f3l -S Approved per applicable codes. 0 Z �_— Z �W aa� JU UO Cl W = �LL W O. LL CJ) d = W ? I•— WO W U13 o - WW U LL ~ O W Z U= O Z F1 Corrections required prior to approval. • i INSPLCTION RECORD Retain a copy with permit ' t INSPECTION NO. PERMI -� CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670" 77 : Type of Inspection: ^ A j t 5 Date Called- - / Special Instructions: Date Wan d: a.m. — p.m. Requester- , Phon No: d 5 — '�' i pproved per applicable codes. Corrections required prior to approval. COMMENTS: I Receipt No.: Date: 7 Z '~ W JU U ND CO W J F_ N LL WO 9_j U. N H= Z H. ZO W W U� �_ 01- WW FF_ LL 111 N U =. O Z paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. r INSPECTION RECORD Retain a copy with permit 0 6. INSPECTION N0. PER / N O . CITY OF TUKWILA BUILDING DIVISION 10 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: Type of Inspection: Add�� s „ e t'YJr9 / � / Date Called: G / b -Uf Special Instructions: Date Wanted: a. m. <5 — I / -- 0 p.m. C Requester: IQ / Pho No: Approved per applicable codes. Corrections required prior to approval. (-i ) Gv //jJ 4 &J � gas --- .4 ,tea P-,,V--d' I Ins pe tor: Date: 7.00 REINSPECTI N FEE REQUIR . Prior to inspection, fee must be id at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. ceipt No.: Date: z �z �W QQ� JU UO to 0 LU J � N LL. WO UQ = �w z H E- O W ~ W U� ON o�- W W Z co llJ H �. O z INSPECTION RECORD �/ Retain a copy with permit D `� r INSPECTION NO. ERM CITY OF TUKWILA BUILDING DIVISION P ;M 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: Type spection: Address: '- Date Calle _..5�. /if - ay Special Instructions: Date Wa ed a.m. Requester Phon . �& pproved per applicable codes. � Corrections required prior to approval. COMMENTS: inspect uate: ( 6— /Y v 7.00 REINSPECTION EE REQUIR .Prior to inspection, fee must be P 7 at 6300 Sou thcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: (Date: I Z �W �U UO N V) L w 0 LLQ co �W ' Z H Wo W U� ON WW W Z 111 U= O z . �& pproved per applicable codes. � Corrections required prior to approval. COMMENTS: inspect uate: ( 6— /Y v 7.00 REINSPECTION EE REQUIR .Prior to inspection, fee must be P 7 at 6300 Sou thcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: (Date: I co W �W ' Z H Wo W U� ON WW W Z 111 U= O z -= INSPECTION RECORD - � - )- f (9 Retain a copy with permit q INSPECTION NO. 4(2 CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 1 -3670 Pr je t: Type of Ins ection: aA Add s : f � ` � ywcw ISpectal Date Called: � 5 Instructions: Date Wanted: a. . p.m. Requester: \ .1 Pho' No: I KI � . 1 - Inspectors - Date: $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: J t Z �W QQ� JU UO U) o W = Cl) LL W O LL_ � = W H Z f. ZO W5 U0. ON o�- WW 2 ILL O ..z U= O Z f INSPECTION RECORD l to Retain a copy with permit INSPECTION NO. P I CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: Type of Inspection NACAVI� Addr ss: I S�' C , j& � Date Called: Special Instructions: Wanted: / r a!6' l l .m. Requester:. Phone No: Approved per applicable codes. Corrections required prior to approval. rA Receipt No.: Date. s ctor: Date: $47.00 REINSPE ION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. COMMENTS: r �_,- — N�FdE J Z �~ W f � JU UO ND J H N LL . WO �Q co = �W Z F- F- O Z F- W U� ON O 1-- WW LL Z tl.l U= O .z C INSPECTION RECORD 45 147 Retain a copy with permit ztI INSPECTION NO. J R No CITY OF TUKWILA BUILDING DIVISION P! 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (2 6 431-3670 Project: Type of Inspec Z�. Add�ss: Date Called: Special Instructions: Date Wanted: p.m. Requester• — Phone No: Ycz"7 I Z 4— 00 N0 C0 W 19x T U- UJ 0 U- 0 :3 UJI M Z f- �0 - z LU 5 co 0 F_ W W M Z O~ Z N Approved per applicable codes. FICorrections required prior to approval. INSPECTION RECORD Retain a copy with permit INSPECTION NO. Z Z �o I//- PER IT CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3670 Project: /. Type of Inspection: JUILC I W. %-CL11 LU W-11CUUM 1t:HDjJt:LL1U11. Date: Address: • Date Called: i 0! Special Instructions: Date Wanted a. m. d Requestqr• _ Phone No: . jjJ41U tt 1 11etro.: 03UV 3UMIMMILCI DIVU., JUILC I W. %-CL11 LU W-11CUUM 1t:HDjJt:LL1U11. Date: i 0! z Uj JU L) 0 (00 Cl) LU LLI J S2 LL W 2� 9-1 U. Cl) CY W 3: 0 z �_ W W 5 U 0 0 a -WW X C. ) LL 0 LLI Z CO 0 O ~ T_ o F- . Tz�kproved per applicable codes. M Corrections required prior to approval. INSPECTION RECORD ` Retain a copy with permit INSPE ON NO. PERM N CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: ,: , Type of Inspection: Address: ate Called: Special Instructions: , Date Wanted: , _ a.m. Requester: r 7 — one No: per applicable codes. R Corrections required prior to approval. Insp r: Date. r b $4 .00 REINSPECTION E REQUIRED. Pry r to inspection, fee must be Id at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: tal Z �_- Z W QQ � JU U CO co W W = H cn U - WO U. a Nd = W H Z� H O Z I W LLJ �p U 0 r- WW LL H 111 Z U= O Z f INSPECTION RECORD tt�� E Retain a copy with permit lid)V 61431-3670 INSPECTION N0. PE CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (2 Projoact: ) Type of I ection• Address: Date Called: 7/ Special Instructions: af Date Wanted: ��� / p.m. Requester: Phone No* r Approved per applicable codes. Corrections required prior to approval. WENTS: nn nnr In ctor -- ] Date:, 2 f e F-1 $ REINSPECTION FEE R RED. Prio to inspection, fee must be t p 14 at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. i Rece pt No.: Date: Z Z �W U UO W= co U. WO LL co C = W ? i~ I— O W F- W U ON 0 H W I— u. O 111 U= OH Z f In ctor -- ] Date:, 2 f e F-1 $ REINSPECTION FEE R RED. Prio to inspection, fee must be t p 14 at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. i Rece pt No.: Date: Z Z �W U UO W= co U. WO LL co C = W ? i~ I— O W F- W U ON 0 H W I— u. O 111 U= OH Z INSPECTION RECORD; r Retain a copy with.- permit _ `: , i INSPECTION N0. PERMI CITY OF TUKWILA BUILDING DIVISION • 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 i i Pro r : tllju Type of Insp ti n: r dr Date Called ecia In ructions: Date Wante n Reques IV � Pho„pe No: � f . Approved per applicable codes. Corrections required prior to approval. Z Z W UO W = �U_ WO 2� J LL j N CY = W H Z�_ ZO U� O� oF_ W H� �Z LLI CO O Z i „? INSPECTION RECORD -�--- Retain a copy with permit -� INSPECTION NO. PIiR O. CITY OF TUKWILA BUILDING DIVISION . 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (Z0 )431 -3670 Project;,,-7/ Type of Insp, ion: Addss: f pate Called: 7 — Z6 Special Instructions: 7 Date Wanted: a.rn, Requester: J Phone No: Fl Approved per applicable codes Corrections required prior to approval. P S v t C r-1 d U� — �. (- AlF�t n pmecto: Dat e: 6,6 E40 .00 REINSPECTION FEE QUIRED. Pri r to inspection, fee must be aid at 6300 Southcenter Blvd., Suite 10 Call to schedule reinspection. Receipt No.: Date: i 1 (G. t z �W QQ� JU UO ND C0 W J x Lo u WO 9:3 co = W ?N z0 W 0 U Cl) OH W O �z U= O z City of Tukwila Steven M. Mullet, Mayor ;p Fire Department Thomas P. Keefe, Fire Chief 1908 TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Permit No. i r j Project Name Address ,�.... ; ? >tl ./ ��1 l Suite # Retain current inspection schedule _ Needs shift inspection } r Approved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: 1- -6.111 4 C' Hood & Duct: 11 Halon : Monitor: Pre -Fire: A— Permits: Authorized Signature `Date FINALAPP.FRM Rev. 2/19/', 9'8 T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East a Tukwila, Washington 98188 • Phone: 206 -575 -4404 • Fax: 206 -575 -4439 z '~ w JD UO Cf) CO W J = C/) U. WO 9_J LL Q W Z H Z� W D� O� OH WW LL ui z U co I-- _ O� Z OTTO ROSENAU & ASSOCIATES, INC. Geotechnical Engineering, Construction Inspection & Materials Testing 6747 M. L. King Way South, Seattle, Washington 98118 -3216 USA Tel: (206) 725 -4600 • Toll Free: (888) OTTO -4 -US • Fax: (206) 723 -2221 WBE W2F5913684 • WABO Registered Agency • Website: www.ottorosenau.com ftc 22 February 2005 Q d? C OM 4 City of Tukwila Building Division �F� PMFNT 6300 Southcenter Blvd. Tukwila, Washington 98188 Project: Cache Permit Numb 4206 Address: 633 Southcenter, Space 204 (Westfield Mall) Job Num We herewith certify that we have completed the following special inspections. To the best of our knowledge, the work inspected was in conformance with the approved plans and specifications and the applicable workmanship provision of the building code. All typewritten reports have been mailed to your office or are enclosed. All reports appear to be complete. This report should not be considered as a warranty for conditions and /or details of the building. Items inspected are: 1. Welds Sincerely, OTTO ROSENAU & ASSOCIATES, INC. Jeanne L. Parvin cc & fax c: Hanna Design Group Zz� if- Z' W 2 �U 00 CO) = H �w w LL _. � = w Z t— I O w ~ w U� O co, o t- wW U' u" O LLi Z CO) O z 07/08/2004 10:34 3055925144 MICHAEL ROSENTHALItS I - , PAGE 02 MICHAEL AOSENTHAI ASSOCIATES planning / design consultants July 7, 2004 City of Tukwila Department of Community Development Permit Center 6300 South Center Boulevard Suite 100 Tukwila, WA 98188 Attn: Official Ken Nelson RE: Cache -711 South Center Mall Plan Check/ Permit No.: D04 -206 Dear Official Nelson: This letter is in response to your plan review comments. 1 T Item #1- see drawing # ID- 6- suspended ceiling attachment and detail added. Item ##2- see drawing # E- 2- lighting revised - lighting compliance info added. Should you have any questions or need any further assistance, please contact me. Sincerely, George Galvin Project Coordinator 8280 n.w. 27"' street suite 506 n iami, florido 33122 n CF I \/E i A Phons:(305) 592.0040 C ' , Fox: (305) 592 -5144 JUL PERM ►T CENTER z H Z JU 00 Cl) C3 C0 W • J� �w w 0 ga- w a N � = CY �w Z � z �- w w U� .0 -. o� W LL O' W z N U- 0 z •�.Jll isoa June 24, 2004 Catty of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director Mr. Chris McComas Express Permits 1327 Post Avenue, Suite H Torrance, CA 90501 RE: Letter of Incomplete Application # 1 Development Permit Application D04 -206 Cache' — 711 Southcenter Mall Dear Chris: This letter is to inform you that your application received at the City of Tukwila Permit Center on June 21, 2004, is determined to be incomplete. Before your application can continue the plan review process the following items need to be addressed: Building Department: Ken Nelsen, at 206 431 -3677, if you have questions concerning the following: 1. Please provide complete attachment details for the suspended ceiling. 2. Please provide a plan verifiable light compliance form per the Washington State Energy Code. Please address the above comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) complete sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messen ,-er service. If you have any questions, please contact me at the Permit Center at (206) 433 -7165. Sincerely, i StefaniApencer Permit Technician Enclosures File: Permit File No. D04 -206 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 * Fax: 206- 431 -3665 Z W. JU UO CO W to � J = H N u- W O U. Q CO) =d F.. W Z 2 F- l— O Z I-- W W U� ON �H W W H U- O Z Lll CO O Z PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D04 -206 DATE: 07 -12 -04 PROJECT NAME: CACHE' SITE ADDRESS: 711 SOUTHCENTER MALL Original Plan Submittal Response to Correction Letter # X Response to Incomplete Letter # Revision # after /before permit is issued DEPARTMENTS: 7� 1 Building Division Fire Prevention ❑ Planning Division Public Works ❑ Structural ❑ Permit Coordinator DETERMINATION OF COMPLETENESS (Tues., Thurs.) DUE DATE: 07 -1 3 -04 Complete E!( Incomplete ❑ Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS R0 TING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: Permit Center Use On CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: DATE: Documents/routing sllp.doC PERMIT COORD COPY 2 -28 -02 DATE: DUE DATE: 08 -10 -04 Not Approved (attach comments) ❑ z 4-z �W 2 D JU U Q co W W_ TW WO La U� = �W z F- E- O z E- W W U CO o E- WW F_ �6O z W U CO 0 z PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D04 -206 DATE: 06 -21 -04 PROJECT NAME: CACHE' SITE ADDRESS: 711 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # afteribefore permit is issued DEPARTMENTS: ,�.0 (� 512 Rw G Bui mg Mvision Fire Prevention Public •22 Structural 1, Planning Division ❑ Permit Coordinator M 0 DETERMINATION OF COMPLETENESS (Tues., Thurs.) Complete ❑ Incomplete Comments: DUE DATE: 06 -22 -04 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg, Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route ❑ Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: DATE: Documents /routlng sllp.doc PERMIT C O O R D COPY 2 -28.02 .;cu. m.r.4a s,.x ... .:.............. ew..:mun:1� :u :.w.1::.:uRu.:. •. ,. � • . - ^.,:.«...... .. .... .......- r�. a.s..ar..•:.c <rumr......x�....a .+,+�ww•+.`�a.^4'... . e. ,......,...........- .,..+...,.. ..._. .. ..: ' .. .. ...' DUE DATE: 07 -20 -04 ❑ Not Approved (attach comments) ❑ z a� ~ w D JU UQ CO NW J 1— S2 U. WO J v_ � =W F- _ z� z� W U� ON off WW U- O .- z W to O z City of Tukwila Department of Community Development - Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 (206)431 -3670 REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: I I I Plan Check/Permit Number: D04 -206 ® Response to Incomplete Letter # 1 ❑ Response to Correction Letter # ❑ Revision # after/before Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: CACHE' Project Address 711 SOUTHCENTER MALL Contact Person Chris McComas Phone u ber (�) Zb 15 + 1 "A C� Summary of Revision: 5 C 0 < T o 11 0L0 1h i i I I i t I Sheet Number(s): D (o C "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: RECEIVED Entered in Sierra on 3" C! nl n of Tllxwl► A J UL 1.2 2044 06/24/04 PERMIT CEN z �z uw LL D UO (n o C0 W J = H �w w� 9 -1 U- a �D = �w z H E- O w ~ w U O - 0 I- wW LL z ui t= � z 1 DGPARTNtENT Of L „ \EOR AND .")UST RIES REGISTERED AS PROVIDED BY LAW AS j CONST CONT GENERAL REGI ST ? •# EXP .. DATE t; i� CC0;1 HANNADG969LD 06 /04/2006. (: `EFFECTIVE'DATE” 06/04/2004 HANNA DESIGN GROUP INC z I 4301 WILMETTE AVE Z. �f ROLLING MEADOWS IL 60008 w w I F625- 053.000 (8197) t,,. V Q - - - - -° - - — -- = — - - -- - -- - - - -- -- - -- -- -- — — - Detach And Display (.coit•icate J 2 N U_ W ton _j v" yp. U. REGISTERED AS PROVIDED BY LAW AS LU z CONST CONT -GENERAL Please Remove H O REGI ST. •# EXP. DATE ' And Si Z � CC01 - HANNADG969LD - 06 /04/2006 7_? EFFECTIVE_ DATE 06/04/2004 Identification v o : DESIGN Card Before p �. HANNA GROUP INC� PlaClila In 4301 WILMETTE AVE Billfold u1 W v ROLLING MEADOWS IL 60008 :.. U. Signature W Z Issued by DEPARTMENT OF LABOR AND INDUSTRIES U O E- F625- 052 -000 (3/97) i Z 1 0 m 0 Q c c a rn y 0 n a� c •wy m m 0 in U 0 W y .H L q__j ai C u 0 It ; r� 1� [D �iAm I i1k,�l�lR- - COVER SHEET ID-1A DEMOLITION PLAN ID -1 GENERAL NOTES ID -2 SPECIFIC NOTES / RESPONSIBILITY SCHEDULE ID -3 PARTITION PLAN / LEGEND / DOOR SCHEDULE ID -4 FIXTURE PLAN FLOORING DETAILS & SCHEDULE / FIXTURE INDEX ID -5 STOREFRONT ELEVATIONS PLAN / SECTIONS / DETAILS ID -6 STOREFRONT SECTIONS & DETAILS ID -7 INTERIOR ELEVATIONS / FINISH SCHEDULE ID -8 SECTIONS & DETAILS E -1 POWER & SIGNAL PLAN / LEGEND E -2 REFLECTED CEILING PLAN / LEGEND E -3 ELECTRICAL SPECIFICATIONS / PANEL SCHEDULE / RISER DIAGRAM M -1 HVAC / FIRE PROTECTION PLAN SCHEDULES / DETAILS / SPECIFICATIONS M -2 HVAC / FIRE PROTECTION - Am #R3 rw��it � MI r NM '� �'� �r�ji�n rr� WESTFIELD SHOPPINGTOWN SOUTH CENTER i ico. 1 : * a CENTER: WESTFIELD SHOPPINGTOWN SOUTH CENTER SEATTLE, WASHINGTON JOSE HERNANDEZ — TENNANT COORDINATOR — PH:310- 575 --5918 HEATHER BLY — GENERAL MANAGER — PH:206 -246 -0423 TENANT: CACHE SPACE #204 WESTFIELD SHOPPINGTOWN SOUTH CENTER 633 SOUTH CENTER SEATTLE, WASHINGTON 98188 SCOPE OF WORK: TENANT IMPROVEMENT / INTERIOR ALTERATION MAXIMUM NUMBER OF EMPLOYEES AT ANY ONE TIME NOT TO EXCEED 3--EMPLOYEES. BUILDING ENCLOSED ONE LEVEL MALL BUILDING DATA: CONSTRUCTION TYPE: 11 N FULLY SPRINKLERED / NON COMBUSTIBLE OCCUPANCY TYPE: M MERCANTILE AREA: SELLING AREA 1377 S/F NON SELLING AREA 225 S F TOTAL GROSS AREA 1602 S F OCCUPANCY (SALES AREA) (NON- SALES) LOAD: ( CODE SO. FT.) (CODE SO. FT.) 1377 225 TOTAL LOAD: 36 -- + 300 = 46 +1 OCCUPANCY LOAD EXITS: 1 EXIT REOUIRED - 1 EXIT PROVIDED SEATTLE, WASHINGTON BUILDING CODE: 1997 UNIFORM BUILDING CODE W/ WASHINGTON STATE AMENDMENTS MECHANICAL CODE: 1997 UNIFORM MECHANICAL CODE PLUMBING CODE: 1997 UNIFORM PLUMBING CODE ELECTRIC CODE: 1997 UNIFORM ELECTRIC CODE FIRE PROTECTION CODE: 1997 NATIONAL FIRE CODE ACCESSIBILITY: 1997 UNIFORM BUILDING CODE CHAPTER 11 AMERICANS WITH DISABILITIES ACT ALL LOCAL ORDINANCES HAVING JURISDICTION SCOPE OF TENANT IMPROVEMENT / INTERIOR ALTERATION / WORK: COMMERCIAL REMODELING CONSTRUCTION MAXIMUM NUMBER OF EMPLOYEES AT ANY ONE TIME NOT TO EXCEED 3 EMPLOYEES. MICHAEL ROSENTHAL ASSOCIATES CACHE Aftn: Lorwft Turk x+:( 305)592 -0040 fox:(305)592 -5144 x,: (212)575 -3281 fox:(212)764 -2129 * -moil: mro- ds9 - 1001- Wh outh.not • -moil: Uurkicocho.com •t J KEY PLAN NOT TO SCALE 1 Y Pin �wNwr app�o�1 Is �f�t�t b �no�s and pe11�1L of co 11a1011 doOMlb don flot the WIoMlon of ow ado0rd aft or daPPm4ml ANdOopyindaon�0l�Isdoip�� { t ..`' • REVIEW MP D L.I�AN CODE COMPLIANCE APPROVED JUL 1 3 ioa City pf Tu cwlla BUILDING DIVISION CACHE SPACE #204 w■QIYm 1bRt ckvof � Ipd d �e !gyp �AL OUC OIVIS�I •.1 1 N AFG'Fi1TFCT I of. WS T WTCOF L r SLATE Of WASI�ICTON RECEIVED JUN 2 1 2004 PEST CENTEK Day -zoo 0 n • " O G a s © a 1 lqT C) ru m (ri v co C) 0 c .c rn 3 XD a_ a in as r C r' Q1 f*1 rr m 0 U . a a In EXIST* DEMISINS WALL TO REMAIN. EXISTING EXIT CORRIDOR EXISr6 SERVICE - DOOR TO REMAIN EXISr6 ELECTRICAL EaAPMENT TO REMAIN EXIST* C01.044 ENGLO3URE5 TO REMAIN, TYP4CAL EXI5TIN6 5TOCK ROOM REMOVE ALL EXISTING FLOOPUNS # CEILING OEMOL.ITION FLAN 1/4' * P-O' • EXISTIN& ADJACENT TENANTS SPACE EX IST* VEMISIN6 AAU. TO REMAIN. __- -J L - - -J REMOVE EXI5 I INTERIOR I I TYPICAL REMOVE EXIST* INTERIOR FIXTUREg, I ( TYPICAL REMOVE EXISrb REMOVE EXISr6 I INTERIOR FIXTURES, FITTING ROOMS, 1 I I TYPICAL TYPICAL REMOVE EX Isr6 5. REMOVE ALL EXI5TIN& WALT. 4 CENTER FLOOR FIXTURES INGUUDIN& SERVICE DESK, SHEL LINIT5, .. N DISPLAY UNIT5, 51&NA6E / D15PLAY5, ETC. COMPLETE W/ L16HTIN& i WIRING. II I I I C ASFW~ — r R J • R 40VM EXI I 'T. I I I INTERIOR FIXTURES, I I ALL EX IST INS GYP. BOARD DEMISIN& WALLS FOR N EK FINISH BY 6EMERAL CONTRACTOR. I I I TYPICAL REMOVE 61.1. CEILIN65 COMPLETE YV/ ALL LIGHT FIXTURES (INCLUDING WIRING t CONDUITS ALL II I� THE WAY TO E). REFER TO ELECTRICAL DRAWIN&5 FOR FULL SCOPE OF NEW WORK. 0 1 09 C d !,. .Ott REMO EMT* REMO EXIST16 I U FIXTURES, -- INTERJOR PARTITION, TYPICAL ��� I I -N, Z = a W 0 EXI5TING ADJACENT TENANTS 5PACE DEMOLITION NO= I. REMOVE ALL EXISTINS SPTOREFRONT CONSTRUCTION AND CORRESPONDIN& STRUCTURE WITHIN CACHE'S LEASE LINE, SOFFITS, ENTRY DOORS, FLOOR MATERIAL, TO NEW LEASE LIME, REPAIR ANY DAMAtSE THAT MIGHT OCCUR AT THESE POINTS AS REWIRED FOR NEM STOREFRONT DESIGN. 2. REMO'V'E ALL EXISTING PARTITIONS, DOORS i FRANE5, THAT DO NOT APPLY TO THE NEW DESIGN. 5. REMOVE ALL EXISTIN& MIRROR,, WALLC.OVERIN6, MOUL0I1465, AND FABRIC AND ANY KALL TO REMAIN. EX I Sr 6 DBHISINS EXISTING LANDLORV'S NEUTRAL PIER TO t--'' REMAIN, TYPICAL I 1 I I i I I I REMOVE ALL EXISTIO ST C4N5TRU0TIGN WoLW1W ENTRY DOORS, CEILIN" NV LWWN6 s El TRIOA -. INr,L VE LLS OVERHEAD MIRROR BAND UP TO BOTTOM OF MAIL L1644TC4VE AT I +14' -0" A". I I MALL I I I � I / L EXISTINb LANDLORD'S NEUTRAL PIER TO �- REMAIN, TYPICAL q. Y*IERE ELECTRICAL YVORK 15 NOT BEINkS REUSED REMOVE ALL EXI5TINb DEVICES, WIRING /CONDUITS ALL THE WAY TO THE SOI.IRCE. DO NOT JJST ABANDON. REFER TO ELECTRICAL DRAWINGS FOR FULL SCOPE OF NEW WORK. 10. REMOVE ALL EX15T'& HVAC DUCTWORK, INCLUDING AEG 6RII I ES, DI FFUSERS , S , 4 UNIT. REFER TO MECHANICAL DRAWINGS FOR FULL SCOPE OF HVAC NEW WORK. II. COORDINATE ALL DEMOLITION 4 BARRICADE YV/ MALL OPERATION5. c �0 I m CORRESPONDING STRUCTURE THAT DOES NOT APPLY TO NEH DMI&N. FOP "' REvxDNE CC)MPLIA E 4. REMOVE ALL EXISTING SHELVIN& UNITS, HANG RODS, BRACKETS, AND HARDWARE COMPLETELY. CO()E w Q m ' ApppoVED 5. REMOVE ALL EXI5TIN& WALT. 4 CENTER FLOOR FIXTURES INGUUDIN& SERVICE DESK, SHEL LINIT5, .. N DISPLAY UNIT5, 51&NA6E / D15PLAY5, ETC. COMPLETE W/ L16HTIN& i WIRING. �a 6. REMOVE 6LL EXISTING FLOOR FINISHES AND ADHESIVE. PATCH, PREPARE, AND GLEAN FLOOR TO R J • ACCEPT NEVI FLOOR FINISH. •�- is 'T. REMOVE ALL FURRING, PANELING, ETC. TO EXISTING 6YP. HOARD DEMISING WALL. PATCH AND PREPARE cl kw SION _ ' ALL EX IST INS GYP. BOARD DEMISIN& WALLS FOR N EK FINISH BY 6EMERAL CONTRACTOR. Sul�D N� D P. REMOVE 61.1. CEILIN65 COMPLETE YV/ ALL LIGHT FIXTURES (INCLUDING WIRING t CONDUITS ALL & o o N THE WAY TO E). REFER TO ELECTRICAL DRAWIN&5 FOR FULL SCOPE OF NEW WORK. 0 1 09 C d q. Y*IERE ELECTRICAL YVORK 15 NOT BEINkS REUSED REMOVE ALL EXI5TINb DEVICES, WIRING /CONDUITS ALL THE WAY TO THE SOI.IRCE. DO NOT JJST ABANDON. REFER TO ELECTRICAL DRAWINGS FOR FULL SCOPE OF NEW WORK. 10. REMOVE ALL EX15T'& HVAC DUCTWORK, INCLUDING AEG 6RII I ES, DI FFUSERS , S , 4 UNIT. REFER TO MECHANICAL DRAWINGS FOR FULL SCOPE OF HVAC NEW WORK. II. COORDINATE ALL DEMOLITION 4 BARRICADE YV/ MALL OPERATION5. c �0 I m JUN 2 1 2004 F"MAT CENTFt� N • a EXI5TIN6 5ALE5 FLOOR REMOVE ALL EXISTING FLOORINO a CEILINS REMOVE EXIST'* INTERIOR FIXTURES, TYPICAL F — - -- — — - --- --- — ----- - -- — f - - - ---" — — — DRAWN CHECKED Cr IS o4 SCALE AS NOTED _ JOB NO. 03 � i 3g SHEET OF 'S�+EErS ft *6.- a w Q m ' N Q O .. N �a • �' x R J • Zer W N x _ a 8 =x _ ' cm �— • 0 a & o o N 0 1 09 C d !,. .Ott (* ci^ aD Z c 0 Z = a W 0 W i W U H p c GOP t O Z - O. dew CL = e � ao 0 W LL Z Z iLl CNTECT s 1ATE oI: w�s�1 a � � JUN 2 1 2004 F"MAT CENTFt� N • a EXI5TIN6 5ALE5 FLOOR REMOVE ALL EXISTING FLOORINO a CEILINS REMOVE EXIST'* INTERIOR FIXTURES, TYPICAL F — - -- — — - --- --- — ----- - -- — f - - - ---" — — — DRAWN CHECKED Cr IS o4 SCALE AS NOTED _ JOB NO. 03 � i 3g SHEET OF 'S�+EErS ft *6.- a .. v 0 C) Cu NT 0 rn Q S~ 7) 10 CU tm a 10 rr in Q) LA- r� m M r+� "z> v CL) 0 -, GENERAL NOTES I. THE GENERAL !AL C414TRACTOR AND ALL 910-CONTRACTORS ARE FA MIIRC'D TO C ECK AND VERIFY ALL DIMENSIONS AND FIELD CONDITIONS AT BUILDING SITE AND PF41MIN S AND NOTIFY MICHAEL ROSENTHAL ASSOCIATES OF ANY AND ALL DISCIR PANCES 1110PORE STAIRTINIG ANY NIORK. 2. ALL WORK ON THIS PRD.ECT SHALL OC IN ACCORDANCE WITH ALL CODES, S S E5, AIRS BUILDING DEPARTMENTS HAVING J USDIGTION. 6BERAL. CONTRACTOR TO CONTACT LOCAL NAL MILS ON'FICIAL.S FOR SPECIFIC OMMIRA54CTS FOR THIS RETAIL USE. S. THE OGC.UPANGY GLASS FOR THIS LOCATION 15 CLASSIFIED AS 14011101ANTIC.E 4. THE GENERAL CONTRACTOR AND THE 'SUB -C4* ACTORS FOR THE GENERAL. CONTRACTOR SHALL PAY FOR AND OBTAIN ALL PERMITS RMURED FOR THE NORK NOTED ON THESE PLANS AND 91 THIS INCLUDES COSTS FOR ALL INSIPECTIONS BY AUTHORITIES HAVING ..MSDIGTION, BUILDING CWARThENT PERMIT COSTS, AND PERMIT CO5TS FOR FIX'IURINO SUPPLIED BY OYML9R Of APPLICABLE). S. ALL POW SHALL CONFORM WITH THE LANDLORDS DESIGN GRITIRIA SUPPLIED BY THE LANDLORD AND MADE PART OF THE TENANTS LEASE. THE GENERAL COWTRAC.TOR 15 TO OBTAIN A COPY OF THE DESIGN CRITERIA FROM THE TENANT AND THE REQUIREMENTS INCORPORATED IN THE CRRITERIA FOR THE GENERAL CONTRACTOR AND TORS NNLL BE PART OF THE BIDS BY THE CONTRACTORS. 6. ALL CONTRACTORS 94AL.L CHECK AM VERIFY ALL FIELD CONDITIONS AND SHALL HAVE SOLE RE5PO1 NSILITY FOR VERIFICATION OF CLEAR HEIGHTS NNTHIN THE PREMISES. ANY DISGREPANGIES SHALL BE TED TO MK.HAEL ROSENTHAL ASSOCIATES IMMEDIATELY. THE GL9ERAL. CONTRACTOR IS TOTALLY RESPONSIBLE FOR ALL N40LOO DIMENSIONS AND IS TO CONTACT M009L ROSENTHAL ASSOCIATES FIRST, PRIOR TO BUILDING HALLS, IF THERE 15 A GLeSTION. TENANTS FIXTURES FIT INTO PLACE NTH NO ROOM FOR ERROR 1. ALL OF PIPES AND DUCT V40RK INSTALLED BY THE GENERAL. R'ANTRAGTOR OR TORS MUST BE MAJNTAJNED FOR ADEQUATE HEIGHTS REWIRED FOR CEILING SYSTEM AND L16HT FIXTURES. THE STOCK ROOM CEILING IF REGMUIRED, SHOULD BE AS HIGH AS POSSIBLE AND WITHIN GORE REGV11REMENTS. TENANT'S MAIN SECTION OF CEILING IS AT 11' AFF. ANY COST FOR REMOVAL AND / OR RELOCATION OF EXISTING UTILITIES, DUCTWORK, SPWINKLERS, ETC., NOT SHOYMI ON ORIGINAL. IN ;K -OUT DRANNSS, WILL BE BORNE BY THE LANDLORD. 6. THE TENT'S GENERAL CONTRACTOR SHALL LAY OUT MIRK AS SPECIFIED IN THE DRANINSS AND SHALL LSE HELD R SPONS19 L.E FOR PROPER ESTABLISHMENT AND MAINTENANCE OF ALL LINES AND DIME)GIONS. BEFORE DOING ANY WORK, TENANTS GENERAL. C.DNTRACTOR SHALL VERIFY ALL AND CONDITIONS AT THE SITE, SPECIFICALLY RESARDING TENANTS CASE FIXTURE LAYOUT AND EXACT PLACEMENT AND NOTIFY 1411004EL ROSENTHAL ASSOCIATES OF ANY DISGREPANGIES VERBALLY AND THEN IN YMtITTING. q. ALL CONTRACTORS SHALL BE BONDABLE, LIC41NSW CONTRACTORS PO56EOIN do 6000 LABOR RELATIONS AND MUST BE CAPABLE OF WALITY WORKMANSHIP, IN HHAP24OW WITH OTHER CONTRACTORS AORKINkS ON THE PROJECT. THE LANDLORDS TENANT COORDINATOR FOR THE BUIL DINIS 15 TO 19E NOTIFIED OF THE NAMES OF ALL SUB-CONTRACTORS PRIOR TO STARTING V40RK - SUCH NOTIFICATION 15 THE RESPONSIBILITY OF THE 65ERAL CONTRACTOR. 10. PRIOR TO COMMENCEMENT OF ANY YORK, THE 60ERAL CONTRACTOR 511ALL CONTACT AND MEET THE LANDLORDS FIELD REPRESENTATIVE FOR A FIRE- CONSTRUCTION M E TIN& AT Y%CoH TIME, HE WILL PRESENT A LIST OF NAMES, ADDRESSES, BUSINN 6, AND HOME TELEPHONE MARS OF THE 5U115- GONTRAGTOR.S FOR THIS PROJECT. II. THE GENERAL GONTRAOTOR A W ALL SUEMCONTRAGTORS SHALL COMPLY WITH ALL THE PROVISIONS OF 05 HA. (OCZA PATIONAL SAFETY AND HEALTH ACT). 12. THE 6EMERAL CONTRACTOR SHALL HAVE AT ALL TIMES, AT THE PREMISES, 'FINAL" LANDLORD APPROVED WORKING DRAWINGS AND E UIL.DIN IS DEPARTMENT APPROVED PERMIT DRAMNGS. 13. THE GENERAL. GONTRRACTOR 15 TO A IRRANSE WITH THE LANDLORD FOR THE BUIL-DINkS, N 4119W BUILDING EQUIPMENT AND MATERIALS ARE TO BE LOCATED AND MOW TRICK TRAFFIC 15 TO BE ROUTED TO AND FROM THE BUILDINS. 14. AN APPROVAL BY THE LANDLORD WILL ONLY BE VALID IF IN WPJTTIN6 AND 516NED BY THE LANDLORD OR BY THE LANDLORDS DESIGNATED R&.X- - RATIVE FOR 5UCHI PURPOSE. THE GENERAL CONTRACTOR WILL BE RESPONSIBLE FOR OBTAINING APPROVAL FROM LANDLORD ON ALL STRUCTURAL GHANk'SES DURING THE COURSE OF THE CONSTRUCTION PHASE OF PROJECT AS HELL AS VERIFICATION OF CORRECT INSTALLATION AND SPECIFICATION FOR MISCELLANEOUS STM FOR RV.A.G., STEEL FOR MEZZANINES, DECKS, ETC. 15. ALL FINISH AND EXPOSED WOOD SHALL 13E KILN - DRIED, MILL QUALITY FINISH AND SHALL RECEIVE A FIRE RETARDANT COATING OR TREATMENT IF lMGIURED BY GODS OR LOCAL FIRE MARSHALL. NO WOOD OR C.OMEIl5TIBLE MATERIAL SMALL BE USED ABOVE THE 5U5PMED C:EILINS UNLESS NON- C.OMBUSTISLE LUMEIER 15 USED AND IS SPECIFICALLY ALLOWED BY B.O.G.A., LOCAL BUILDING► GORES, THE FIRE MARSHALL AND ALL A &ENGIES HAVING J IRISVIGTIOM. IF FIRE TREATED HOOD 15 REWIRED FOR FIXTURIN S ITEMS, THE GENERAL CONTRACTOR IS RE5P'rONS'ME FOR E)MCUITIN S THIS WORK A5 PER BUIL.DINS OFFICIALS' REPRENENTS. 16. THE GENERAL. GO 47RA CTOR SHALL FURNISH AM INSTALL, AS REWIRED, HAND OPERATED FIRE EXTINSUISH FIRS UL. RATED, AS PER LOCAL CODE REMJIREMENTS; PLAC EM ENT AS APPROVED BY TENANT. 11. ALL CEILINGS, IF REWIRED, SHALL BE UNDERNRITERS' APPROVEED AND OF THE NOWCOIMEUSTIBLE TYPE. 18. THE 6ENERAL CONTRACTOR SHALL 15E RESPONSIBLE FOR DAILY REMOVAL, OR AS REO ARID BY LANDLORD, OF TRASH, RLEBISH AND SLPRI LU5 MATERIALS RESUL.TINS MOM GOISTTRUCTION. THE GENERAL CONTRACTOR MUST MAINTAIN A CLEAR PATH OF 66RESE3 FROM THE PREMISES FREE FROM TRASHI AND 1RUBBISH AT ALL TINES. 19. THE GENERAL CONTRACTOR SHALL FURNISH AND PAY FOR ALL TEMPORARY UTILITY SERVICES, IF SUCH GOATS ARE SPECIFICALLY NOTED IN THE LEASE TO BE PAID FOR BY THE TENT, THE GENERAL GONTRACTOIR 15 NOT TO INCLUDE SUCH COSTS IN THE BID. 20. THE GENERAL CONTRACTOR SHALL IMMEDIATELY ORDER ALL LONG LEAD EdIU PMENT AND NOTIFY THE CLIENT IMMEDIATELY OF ANY REGARDING AVAILABLITY OR DELIVERY AT THE 86131NNNG OF THE PROJECT. 21. THE GENERAL. CONTRACTOR 15 TO VERIFY ALL ECxJiPI►ENP S'EGIF"TONSS AND praVIRENIENTS NTH THE TENANT OR MICHAEL ROSENTHAL MATES PRIOR TO THE START OF CONSTRUCTION. COORDINATION NNTM THE EL.EGTlRICASL. SUSC04TRAGTOR 15 MANDATORY TO CAREFULLY CHECK ALL DRAMMS AND VERIFY ECSNJIPMMT SEL.ECTION AND GC>RREGT VOLTAGES, AMMR:RAbES, AND PHASING. 22. THE GENERAL CONTRACTOR AND/Olt ELECTRICAL 9AIG414TRAGTOR IS TO INSTALL (OWNER SUPPLED) EM AND EXIT LIGHTING, AS 1111801011RED BY LOCAL CODE OR AGBIiGIIS Hrr1VINd► .ZN jWIGTION OVER THE 1PRO.EGT. THE LVT/EIR6MY LWINTING SHOULD BE PRROM RLY LABELED AND APPROVED TYPE LOCK -GUT'S MOTALLI D. 25. THE 604VA L. CONTRACTOR SMALL SUPPLY ALL NECESSARY 64OLMS FOR MILLJ+ M AND FIXTURESS, FITTING'S, AND EGIMIPMENT IREGIJIIIEP. 24. ALL STONREFNRiONf AND Iwmm GLAZING MUST GOMR'LY nTH ALL APPLIGABL-E CODES, LANOLORD'S GR11TERIA, TENANTS DRAI"MNGS AND 'JS11f'ETY 6LAZINIG STANDARDS. r • S r �. ANY SMTITUTIONS OF FINISH MATERIALS NAT BE ARPROVW BY MICHAEL ROSENT'NAU, ASSOCiIAT96 IN WRITING. THE 604 RAL CONTIRACTIOR IS IR!!SPi0Ni1BLE MR SUWITTIM Two (2) SAN IPM OF EACH !LE!lbTITUTION. lib. AL.L PLOOR SLAB PQETRATIONS FOR PL.UMlJilM FIXTURES AND CRAWS SHALL HAVE INATERTIONT SLEEVES EXTENDING A MIMMUM 4' APP. AND MUST BE I NSTALLED PER LANDLORDS CRITERIA. IJr = LEVEL. SLAM (IF APPLIC•ASNLEJ MAY ONLY BE GORE - DRILLED. IF TENANT 15 ON U1 LEVEL, M IREMOMBILITY, COSTS, AND COORDINATION OF V 0WINO IN A SPACE BELLOW TENANTS SPACE FOR M.EGTRICAL AND PLA40NO V40RK, WILL BE BORNE BY THE 60011AL CONTRACTOR 29. THE 4CMI AL. CONTRACTOR AND ALL SUB-CONTRACTORS ARE TO FAMILIARIZE TH EMISEL.VES WITH THE Am TO Be PIRPORM ;w BY THE LANDLORD AND BY THE TENANT AS PART OF THE "00107W LEASE AHti 11 0IMENT AND ANY AND ALL VISION CRIT " RA. ANY DISCREPANCY BErAM THESE DRANMN" AND THE LEASE OR DESIGN CRITERIA IWOIRMATION IS TO BE R... - w - r%I TO MICHAEL ROSE CRIAL AWOCIATES PRIOR TO THE START OF ANY AORK. 26. ANY SGAFFOLPIN6, SAFETY RAILINGS, eARMCADESS, AND /OR PROTECTION DEVICE 111201IRW FOR THE PROJECT WILL BE FURNISHED AND PAID FOR BY THE GENERAL. CONTRACTOR AS PART OF THE SAM BID. 24. PROTECTION OF WORK IN WORK PLACE- WORK IN PLACE THAT 19 5 ALMT TO INJJIRY BECAUSE OF OPERATIONS BEIM CAPMW ON ADJACBIT THERETO SHALL BE COVERED, BOARDED UP, OR SUBSTANTIALLY ENCLOSED NTH ADEQUATE JATE PROTECTION. ALL FORMS OF PROTECTION SHALL BE CONSTRUCTED IN A MANNER SUCH THAT, Lrm COMPLETION, THE ENTIRE WORK NMLL Be DELNERw TO THE OWNER IN PROPER IIHOL.E, AND UNBLEMISHED CONDITION. ALL SUCH V 0W SHALL BE COORDINATED WITH THE LANDLORDS 11.7 REMffAnvm 30. THE STRUCTURAL SYSTEM OF THE SMOPM'IN6 CENTER HAS BEEN DESIGNATED TO CARRY A MAXIMUMS LIVE LOAD AS SPWIFIED IN THE LANDLORDS C.RJTMA. LOADING IMPOSED BY ANY OF THE TENANT'S WORK ON A TEMPORARY OR BASIS SHALL NOT EXCEED SUCH SPECIFIED LOAD. SI. ANY ALTERATIONS, ADDITIONS, OR REIWOR,CENENIS TO LANDLORDS STRUCTURE TO ACCOMMODATE TENANTS WORK SHALL NOT BE PERFORPW WITHOUT IN EACH INSTANCE TENANT OBTAINING LANDLORDS PROOF MTTEN APPROVAL, AND THE GENERAL COMRAGTOR IN PERFORMNIb THIS AOIRK, SHALL LEAVE LANDLORDS STRUCTURE AS STRONG A5, OR STRONGER THAN, THE OR16INAL DESIGN AND WITH FINK-44M UNIMPAIRED. 92. THE TENANT SHALL APPLY FOR ALL UTILITY METERS. 98. SPRINKLER SYSTEM DES16N AND LAYOUT TO BE PROVIDED BY S N KLER SUB- CONTRACTOR, AND ALL SUBMIISeHAON S TO THE FIRE MARSHALL AND BUILDING INSPECTOR FOR THE NECESSARY APPROVAL- ARE THE RESPONSIBILITY OF THE SPRINKLER SU TOR SPRINKLER HEAD SPACING TO &WOR,M HTH THE LATEST NPPA. STANDARDS AND ALL CODES HAVING JJURISDIGTION. IF THE ARGHITUGT INDICATES ERIN KLER HEAD LrOGATIOW, THEN THESE SN'lRJN KLER HEAD LOCATIONS ARE TO BE RELOCATED, MODIFIED, OR ADJUSTED AS IREQLJIRED, BASED ON TENANTS FLOOR LAYOUT AND REFLECTED CEILING PLANS. SHOP DRANNN& SUBMITTAL AND APPROVAL TO THE LANDLORD AND ALL 60VERNIN6 AGENCIES BY THE SPRINKLER SUB-CONTRACTOR 54. THE ELECTRICAL TOR 15 TO PROVIDE A CIRCUIT DIRECTORY WITH PROPER PHA51NI6 AND BALANCING, MICH 15 TO CONFORM TO THE LATEST EDITION OF THE NATIONAL. ELECTRIC C-ODE AND UNDERYSRITERS CODE. THE SIWS) JUNCTION BOX PERMIT 15 TO HE INGLLJiDED IN THE POW FOR THE ELECTRICAL SUB- GONTRAGTOR AND THE BOX 15 TO 19E DIED BY THIS CONTRACTOR AND PROPERLY LABS. H OOKA P TO THE LIGHT SOURCE FOR THE 516N BY THE ELECTRRICAL STUNS - CONTRACTOR. 95. THE MECHAMUGASL TOR 15 IRESPpNSIBLE FOR VISITING THE SITE PRIOR TO 5UE MT71NO A BID FOR THE WORK ON THIS PROJECT. THE CONTRACTOR MST FAMILIARIZE HIM5ELF WITH THE FIELD CONDITIONS. 96. ALL TOILET ROOM 5 TO BE WATER RESISTANT, FIRE - RETARDANT, IF REG UIRED, AND 5/6 THICK. 57. THE GENERAL CONTRACTOR SMALL COORDINATE WITH THE MC44MICAL S UB- CONTRACTOR TO INSTALL ALL NECESSARY MISCZLLANEOUS STRUCTURAL STEEL SHAPES TO 19E INSTALLED NNERE DIRECTED BY THE LANDLORDS REPRESENTATIVE AND THE TYPE OF EWIPMENT NECESSARY FOR TENANTS DEMISED PRI MISE5. W. ALL TROCK TO BE 5J8' GYP" WALL BOARD, FIRE CODE 'X' BOTH 540M. ALL METAL STUDS TO BE 5 50' METAL STUDS - 25 6A. OR AS PER GORE AT 16" O.G. TO UNDERSIDE OF DECK ABOVE UNLESS NOTED OTHERNSE. DEMISING WALL FIRE RATING TO BE D'E'TERMINED BY GENERAL CONTRACTOR RESPONDING, TO LANDLORD AND CODE REGIAIREMENTS. 9q. A.L. TROCK TO BE APPLIED VERTICALLY ON WALLS LPM.ESS NOTED OTHERWISE. ALL SHHEETROGK TO BE FIRE RESISTANT /NON -GOM OU TIBL.E AS SPECIFIED BY LOCAL CODES. 40. ALL METAL FRAMING, TIROCK PARTITIONS, SOFFITS, AND FACADES BY THE GENERAL GONTRRACTOR, UNLESS OTHERNM NOTED. 41. ALL TROCK TO BE FIRETAPED AND SPACKLFD THREE (5) GOATS, SANDED, AND READY TO RECEIVE PAINT AND WALLGOVERINS. 42. THE GENERAL. CONTRACTOR TO INSTALL TROCK AND REJNRM FIRE SAFIN6 TO UNDERSIDE OF DECK ABOVE, AT DEMISING INALLS AND AT ST WALL NNERE REQUIRED. A COMM'LETE SEPARATION BET'NEEN THIS TENANT AND ALL ADJJAGENT TENANTS AND MALL 15 TO BE PROVIDED. 45. ALL DOORS, DOOR FQAM13, TRIMMED OPENNN65, AND HARDNIARE, INCLUDING LOCKS, TO BE PROVIDED BY THE GENERAL CONTRACTOR TOR UNESS OTHERY41SE NOTED. THE DOOR AND DOOR FRAME BETH!EN SALES AREA AND STOCK ROOM TO BE HOLLOW METAL. - B' LABELED DOOlt 04JMS OTHERNSE NOTED ON VV%S" ). 44. THE 60CRAL G04TR4GTOR 15 RE5PONH5I ME TO GUT AND FRAME ALL OPENUN65 FOR OTHER TRADES, SUCH AS MECHANICAL., PLUMBING, ELECTRICAL., THRU PARTITIONS AND STRUCTURAL WALLS. 45. THE GENERAL. CONTRACTOR AND ALL SUB- CONTRACTORS rtMCIN6 ON THIS PROJECT ARE IRRSI°IONSIBLE FOR CONTACTING THE RALNG UTILITY COMPANIES SUPPLYING UTILITIES TO THE AREA, VENIRE THE PROJECT IS LOCATED, IN ORDER TO VERIFY LOCATIONS OF UTILITIES, U40ElLbROUND AND OVERHEAD, AND SECURE THE PROPER PROCEDURM NHIL.E YrORKING ADJACENT TO, ABOVE, OR NEAR SUCH UTILITIES TO AVOID ANY PROBLEMS NTH E) PLOSSION5, DISCONNECTIONS, REMOV0 , ETC. 46. M4% BIDDING THIS PROJECT, EACH CONTRACTOR SHALL BE RE5Pi0N51BL.E FOR VISITING THE SITE PRJOR TO BIDDING AND VOW"If INS EXISTING CONDITIONS AS REFLECTED IN THESE CONTRAST . ANY EXTRA WORK 1111501011IMM BUT NOT INCLUDED IN THE DOCUMENTS SHALL W IMMEDIATELY TO MICHAEL ROSENTHAL ASISOGIATES. 49. THE GENERRAL CONTRACTOR IS RE00111RED TO FAMILIARIZE ALL F011 AND S GTC7 'SST YMORKING ON THIS PROJECT NTH TIME GENERAL. NOTE'S AND THE CONTRACT VOCAMM NOTED IN THESE DRAI'SNN65, LANDLORDS 01NON CRITMA4 AND THE EXECUTED LEASE AGREEMENT BETMMN LANDLORD AND TENANT. THE TENANT'S 6B49R/1L. CONTRACTOR SHALL W BIBLE FOR FULLY ACQUAINITINb HNMlSELF NTH THE CONTENT'S AND 9 4PE OF 'THESE SPECIFICATIONS, AMP 9 9MIAL ATTLS RrOM "AD BE OIVENI THE SPECIFICATIONS TH ROUSH10UY THE SPAN OF THIS PROJECT BY THE TEN A?" GENERAL. C 14TRACTOR'S, SUPERVISORS, AND TORS, AS THE 'STANDARD ESTABLISHED HEREIN SMALL BE APPLIED, 1 OPP41ASIS TO ALL vest AAED UNACCEPTABLE BY THE OHI R SMALL BE CORRECTED M A MAVI!!R AND TO A PUME OF WALITY AS ACCENrTAa.E BY THE OVOW 48. TZNANT"S deC RAL. CONTRACTOR AND ALL NMI Il Af TORS AM REGiUNR D TO lS1JIRMSH TIE POW -OHM MINK" WVERAII a AND LIMITS OF LIABILITY. IF "S RI MJ R MBNT(S) ARE MORE NIUMEROUS IN TYPE OF COVMAM OR MORE SIMMENT, THE 40011AL. CONTRACTOR IS 1 TO ADHERE TO THE ADDITIONAL RlMRCM!'NT'S AND THE MOOT STRINIdENT OF THESE RCaMJNIREMENT'S. A. YVMMANS COMPENSATION, AS RM UIIRCD BY STATE LAK AND IN"=NG 04%V MS LIABILITY INBLNRANGE HTH A LIMIT OF NOT L!" THAN $2000A00 AND ANY INSURANCE REQUIRED BY ANY 0011PLOY 2 BENEFITS ACT OR OTHER STATUTES APPLICABLE NMERE THE NOW IS TO BE r1i~ ORMID AS HLL PROTECT THE CONTRACTOR AID'ONES- CONIRACTORS FROM ANY AND ALL LIABILITY LINPI t THE ACT'S. B. 001041"RdMENSIVE 60ERAL LIABILITY INSURANCE (INGWDING CONTRACTOR'S PRDTEGTIVE LIABILITY) IN AN AMOUNT NOT LESS THAN 62JO00OW FOR ANY ONE YMETHEIR INVOLVING BODILY INJSRY LIABILITY (OR DEATH IRI SULTING THERr r'ROMI) OR PROPDRTY DAMAGE LIABILITY OR A COMBINATION THEREOF HTH A AGGREGATE LIMIT OF $2400000. SUCH INSUP44 r Z SHALL PROVIDE FOR EXPLOSIOR COLLAPSE, AND . SUCH INSURANCE !.SHALL INSURE TENANTS 60 tAL CONTRACTOR AGAINST ANY AND ALL CLAIMS FOR BODILY INJJIRY, INCLUDING DEATH IRESX-TIN O THERE FRROM AND DAMAGE TO ON DESTRUCTION OF rwk w 11C I Y OF ANY KIND V44ATSOEVER AND TO NSIOMEVER BELONGING AND ARISING FROM 49 OPERATIONS UNDER THE GQNTRAGT AND YSETFER SUCH OPERATIONS ARE ..11. RME.D BY TENANTS GENERAL GONTRAGTM SUB- CONTRACTORS, OR ANY OF THEIR TORS, OR BY ANYONE DIRECTLY OR INDIRECTLY EMPLOYED BY ANY OF THEM. 6 C RAL. CONTRAC PRO TEGTIVE LIABILITY INSURANCE GENERAL CONTRACTOR SHALL PROVIDE OVI ERS PR01WTIVE LIABILITY INSURANCE AS WILL INSURE GENERAL GUNTRAC.TOR AGAINST ANY AND ALL LIABILITY TO THIRD PARTIES FOR DAMAGE WC OF BODILY INJURY LIABILITY (OR DEATH FIESU -TWIG THEREFROMU AND PROPERTY DA #04E LIABILITY OF OTHERS OF A CAM3INATHON THEREOF WHIG#I MAY ARISE FROM WORK IN CONNECTION WITH THE LEASED PREMISES, AND ANY OTHER LIABILITY FOR DAMAGES YGIC 4 THE T54AWS GENERAL. CONTRACTOR AND /OR TORS ARE MIRED TO INSURE AGAINST UNDER ANY PROVISIONS HEREIN. SAD INSURAN V! SHALL BE PROVIDED IN MINIMUPI AMOUNT'S AS FOLLONLN A. BODILY IN.ZRY, PER OCHE FOR PERSONAL IN AI RY AND /OR DEATH B. PROPERTY DAMAGE LIABILITY *5P OjOOO 6ENERAL. GONTRAGTORS BUILDERS RISK INSURANCE- C-0.01P LETEID VALUE BUILDERS RISK MATENAL DAMAGE INSURANCE GONERAW.. GENERAL CONTRACTOR SHALL PROVIDE AN 'ALL PHYSICAL LOS SO BUILDERS RISK INSURANCE POLICY ON THE V40RK TO BE PERFOIRME[D FOR TENANT IN THE LEASED PREMISE'S AS IT RELATES TO THE BUILDING WITHIN WHICH THE LEASE PIRE MUSES 15 LOCATED. THE POLICY SHALL INCLUDE AS INSIPRED, TENANT, TENANTS ARWITEGT, MICHAEL ROMW14AL ASSOCIATES OF APPI- 1GA8W, ITS CONTRACTOR AND STUB- C414TRACTORS, THE LANDLORD, AS THEIR INTERESTS MAY APPEAR THE AMOUNT OF INSURANCE TO 8E PROVIDED SMALL BE 100% OF THE REPLAC434 tT COSTS. THE GENERAL CONTRACTOR 15 REWIRED TO LIST ALL ADDITIONAL INSUREDS AS PER LANDLORDS CRITERIA IN ADDITION TO MICHAEL ROSENTHAL ASSOCIATES, AND TENANTS ARCHITECT. INSURANCE REWMEII -S NOT OBTAINED BY THE 6ENIERAL. CONTRACTOR AS NOTED ON THE DRAWIN66 AND IN THESE SPECIFICATIONS WILL NOT RELIEVE THE GENERAL CONIIRAGTOR OF THE RE5F`ONSI5ILITY OF LIABILITY(5) FOR THIS PROJECT. A DOPY OF ALL INSURANCE PAPERS ARE TO 8E SENT DIRECTLY TO THE TENANT, NOT ONLY FOR REVIEW BUT FOR RECORD PURPOSES. 44. THE GENERAL CONDITIONS OF THE C40WR.ACT FOR C436TIRLICTION- ISSUED BY THE APERIGAN INSTITUTE OF ARC4*TEGT5, IIDI EDITION RELATES TO THE WORK OF THIS PROJECT AND 15 HEREBY MADE A PART OF THESE PRAT WNG5 AS THOUGH FULLY CONTAINED IN THESE DRANN5S. THE OWFRiR HILL UTILIZE A.I.A. DOCUMENT A-101 "STANDARD FORM OF BETYEEN OWNER AND CONTRACTOR AS THE CONTRACT DOIC001ENT. 50. THE TENANT'S GENERAL. CONTRACTOR AND ALL TORS SHALL BE RE5PUMH5IBLE FOR OBTAINING THE NEGE'9SARY NJM INX OF COPIES OF A-201, TO AC4VAIN r HIMI5ELF WITH THE ARTICLES CONTAINED THICREIN AND TO IREVIEK WITH ALL 90-CONTRACTORS, SUPPLIEft, AND ANY OTHER PARTIES TO THE CONTRACT OR INDMOUALS OR AGENCIES ENGAGED ON THE WORK AS TO ITS C4NTENIS. 51. THE TENANT AND MICHAEL R05ENTHAL ASSOCIATES, NTHH= INVALIDATING THE CONTRACT, MAY ORDER EXTRA MORK, ALTER;, ADD TO, OR DEDUCT FROM THE CONTRACT WORK THE C A TRAACT SUM SHALL BE ADJUSTED ACCORDINGLY AND SUCH COSTS SHALL BE COMPETITIVE WITH LOCAL CONSTRICTION COSTS. 52. 6UAfRANTEES FOR ALL WORK BY 5U9-C4 NTI AGTOR5 SHALL BE FOR A PERIOD OF ONE YEAR UNLESS SSE NOTED. AT THE TIME OF FINAL SUBMITTAL. FOR ALL COSTS, IWA.IUDINS BASE BID, EXTRAS, AND CREDITS, THE 51JB- C4NTRAGTOR5 SHALL FURNISH TO THE GENERAL C4XORAt'TOR A ARITTEN 6UARA NTEE 5TIPUL.ATINb THAT, AT NO ADDITIONAL COST TO THE 6ENERAL CONTRACTOR OR TENANT, ANY DEFECTIVE WORK OR MATERIALS SHALL BE REPAIRED OR REPLACED FOR A PERIOD OF ONE YEAR AFTER ACCEPTANCE OF MORK, UNLE'Sb OTHERNSE NOTED. IF • dH Pt*X AfFEGTS LANDLORDS VVRJ -, LANDLORD'S NIIRRK 15 TO BE GOMM°LETED BY THE S ,ONTRAGTOR AT NO G05T TO THE TENANT. !93. ALL PAYMENTS MADE TO THE GENERAL WN TRACTOR FOR THIS PROJECT ARE TO BE ALLOCATED FOR THIS PROJECT ONLY FOR PAYMENTS TO TORS, MATERIAL MERE, AND AGENTS AUTHORIZED BY THIS CONTRACT TO PERFORM WORK OR SUPPLY MATERIALS TO THIS PROJECT ONLY. THE GENERAL CONTRACTOR 15 REQURED TO SUBMIT PARTIAL WAIVERS OR LIENS FOR HIS V40RK AS NEL.L. AS TORS OR MATERIAL SUPPLIE'iZS, UPON REC4JE5T OF THE CLIENT OR CLIENTS ARCHITECT AND THE REQUEST FOR THE FINAL 10% RETENTION ON THIS PROJECT MST INCLUDE SWAM AND E VWVEIRS OF LWN INDIGATIMb 100% C 4P L.ETION AND 100% PAYMENT IN FULL, BY ALL SUB- CONTRACTORS AND MATERIAL 'SUPPLIERS. 54. NO EXTRAS FOR C45T5 GAUD BE AUTHORIZED UNLESS APPROVW BY THE ARCHITECT, THE PROJECT COMPANY FOR THE TENANT, OR THE TENANT. AN IS&JANGE OF CREDITS TO BE CACIJL-ATED BASED ON COMPETITIVE RATES AND EGI IPMENLT COSTS APPROVED BY THE APLATECT, THE PROJECT A MA 09EMENT COMPPANY FOR THE TENANT, OR THE TENANT. 56. THE GONNTRACTOR AGREES THAT IN P GE OF THE WORK GALLED FOR BY THE CONTRACT, THEY WILL EMPLOY ONLY SUCH LABOR AS WILL NOT DELAY OR INTERFERE NMTH THE PROGRESS OF THE PROJECT A040 AS MLL BE ACC.EPT'ABL.E TO AND Y40RK IN HLAIRMN W WITH ALL OTHER CONTRACTORS EMPLOYED ON THE C4 ML5TRUCTION 51TE OR ON ANY OTHER BUILDING, STRUCTURE, OR OTHER IMMP"ROVEMENT HITHER PUBLIG OR PRIVATE F"CH THE GENERAL. CONTRACTOR MAY THEN BE EREGTINIS OR ALTERING IN OTHER LOCATIONS. 56. UPON GGM'LETION OF V40PK, THE GENERAL CC.INTRAGTOR AND ALL '.SLIB- CONTRACTORS ARE TO OBTAIN A CERTIFICATE OF GOMNSUTION AND APPROVAL P`POM THE OIAL -DINS 001PARTMENT, OR OTHER AUTHORITIES HAVING 4 tISDIGTIGN. AND S4EMAT SAME TO THE TEN ANT'S ARCHTECT. 19NAL PAYMENT HILL NOT BE ISSUED FR Olt TO RECEIPT OF SU " GBRTIFIGAT6(S). I". FOR CL-ARIFICATION PURPIOSES, TENANT, CLIENT, AND OWNER AM THE 'JAM+E PARTY, LANOLORV IS THE PARTY LEA&M THE SPA" TO THE TENANT AND THE 61ES9RA1- CONTRACTOR NNLL BE REOUIRED TO HANDLE ALL YrORK IN THESE voc4mpm UNLESS SPECIFICALLY NOTED OTHER NEE. !*. THE GENERAL. CONTRACTOR IS IREGUIRE D TO FURNISH AND INSTALL A REAR EXIT DOOR AND APPROVED TYPE DETEX PANIC BAR A99041ILY, PAINT OUT"SI IE Of C CC It AS PER LANOLOW S REGMUIREM!'NT�S. w THE 6914ERAL CONTRACTOR SHALL UNLOAD, PROTECT AND INSTALL (INSTALL ONLY IF NOW TO DO 50), TZNANT"S B MUIPM NT, FIXTURES, AND FUIMSMN6S. 60. THE TENANT'S DESIGN CONCERT LEAVES ZERO OR MINIMAL CLEARANCE FOR EIRIRC m IN REGARD TO FIXTURE LAYOUT. 'HOLD DIMESION' IWCATkM ARE TO a ADHERED TO AND THE CONTRACTORR IS TOTAL RtSPGNSIBL.E FOR ERROR OR OMISSION. ANY tLMESTIONS► RELATING TO DIM ENSIONNG ARE TO W ADDRESSED TO MICHAEL ROSENTHAL ASSOCIATES OC.IATES ONLY. 61. THE FLOOR FINISHES, WITHIN THE PREMISES, OR AT THE TRANSITION WTYEEN LANDLORD FLOOR FINISHES AND TENTS FLOOR FINISH'S (AT ENTIRY OR (REAR DOOR IF APPLICABL-EJ ARE TO BE SMOOTH AND LEVEL. TO AVOID TRIPPING HAZARDS AND BE YWTHNN THE REGUIRINENT5 OF BA 4010 QR FREE DESIGN. 62. TOTAL "CAN THE 4CHM& 414TRAvCTOIR 19 TO PERFORM A TOTAL. C4.EAN4JP PRIOR TO TURMM6 SPACE OVER TO 'CASCHE' FOR MERCHAN" DISIMG. THIS GLEAN4PP` 15 TO INCLUDE THE FOLLOWING ITEMS BUT NOT LIMITED TO; • C 2MINS OF STOREI'RONf 6LAW AND DOOMS • POLISHING OF STOREFRONT' 516N • WIPE Dk7Nf+l AND C42MN EP OF ALL WALL, SHOVICASE AND LOOM FIXTIRING (INGLIJDHNIG MIMRR4R5, GLASS PANELS ON TOP OF GA884ORK., GLASS TOPS AND SHELVES WITHIN FIXTUIEW • VACUUMING OF FITTING ROOM CAIRPET • GLEAN 4 APPL 2 GOATS OF COMMERCIAL KAX TO VINYL FLOOR IN !STOGIE 4 TOILET ROOMS - ALL VINYL FLOORS MST HAVE A 1405MT SHINE'. • PORCELAIN CERAMIC TILE FLOOR IN SAUM AREA - VACUUM, Lk MTLY WASH NV VINEGAR 4 NATER. THE GENERAL CONTIRACTOR 15 TO FILL ALL NAIL HOLES AND .JOINTS, TOUGH UP AS REWIRED, AND C40PVNATE ALL FINAL V40RK REMAINING WITH ALL TORS 50 AS NOT IMPEDE 'TOTAL. GLEANS -UP BY GENERAL CONTRACTOR'. THE GENEIRAL. CONTRACTOR IS TO NPE DOM AND CLEAN CEILING TILE AND 6RD, CEILING L16HT FIXTURES. ADJUST ANGLE AND DIRECTION FOR ALL CEILING ACCENT L1614T FIXTURES AND SHOW WINDOW TRACK L16HT FIXTURES (ADJUSTMENTS TO BE MADE BURRING SING PRIOR TO STORE OR MNG AS DIRECTED BY CACHE). 65. THE 6M AL CONTRACTOR 15 REWIRED TO HAVE ALL TORS REVIEW THE ABOVE NOTES PRIOR TO 5110171M AND TO FOLLOA- P AND EXECUTE AS NRITTEN. 64. THE GENERAL. C NTIRA CTOR, GA DNETRY CONTRACTOR GASHES FLOORING CONTRACTOR, 4 CACHES 516N CONTRACTOR WILL HAVE A MAXIMUM OF SO DAYS TO 001` - ETE ALL PUNCH LIST ITS TO CACHES SATISFACTION. AFTER THIS 'JO DAY TIME PERIOD CACHE WILL TASKS STEPS TO COMPLETE ANY AND ALL OUTSTANDING PUNCH LIST ITEMS - BACK C+Wt&ING ALL COSTS INVOLVED TO RESPECTIVE CONTRACTOR • po cn►Ik O NCE pE C pMp1.1A Appi tolf-1) & 131004 - -�kwila City Of 11 SZpN No ' ���Wb a JUN 2 2004 11 REVISIONS DRAWN CHECKED OAT G 04. SCALE NONE JOB NO. 03113q SHEET O SHEE-S t S ,... 6 '4 b m 4 N •'�i d UN�� �h �N Z • P � § F =NF 8 w 0 J$ d i ... c Z p Z W a z z ILI 65M EST ^T [" N41,= T WTCK! I STATE OF Wa4NGT A DRAWN CHECKED OAT G 04. SCALE NONE JOB NO. 03113q SHEET O SHEE-S t S ,... 6 1 4 a ru 0 rJi m u 0 C q 3 rr a b a rn m m c:) V U �1 U • S i SPECIFIC N07E5 OFF - SITE PACIC"Ci SULLIED BY CABINETRY CONTRACTOR FIELD INSTAUM BY O"TE 0110MA. CONTRACTOR I. OENEIRAL A. S' HIGH AOW DAN TO DE FIELD INSTALLED. RUN CONTINUOUS AROUND FIN WALLS, FITTING ROOM PARTITION15, AND ALL EXPOSED SALES FLOOR WALLS MITER GUT INSIDE AND OUTSIDE C000%. WOOD SAM TO W SHILED IN I2' LOOTHS AND FIELD INSTALLED. REFER TO ELEVATIONS FOR EXTENT OF AORK. 2. FITTING ROOMS A. FITTING ROOM PACKAGE BY CABINETRY CONTRACTOR TO INCLUDE, WOOD DOORS, CASINGS 4 HAROKARE; WOOD RASE; WOOD L164T VALANCE; +.TIDE WALL WOOD P ANELS AND HANDICAP WOOD MOM. HS. CI STOM MAPLE` WOOD DOORS 4 FIlAHM - RCI"CR TO DOOR SGiePAX ON ". 1" FOR SPECIFICATIONS. ALL DOORS TO BE INSTALLCIP WITH SATIN CMRRObE FINISH LEVER HANDLE LOCOMT, STGREEROONI FUNCTION. ALL DOORS TO BE KEYED AL I KE. C. THE DOOR .LAMES IS TO Be MAPLE FINISHED Q WITH A FLAT PROFILE CASIN16 ON BOTH SIDES OF DOOR. 5. 0ASIi"11tAP AREA A. THE GASH WRAP REAR WALL COUNTER 15 TO BE FADRIGATE97 NTH A ONE PIME LOOSE COUNTER TOP. B. A METAL U GAP WTH ROAD 15 TO BE INSTALLED IN THE BACK CABINET. C. ALL IREGEPTAGLES INGLUDIN6 AN ISOLATED CIRCUIT ARE TO BE INSTALLED INSIDE THE BACK CABINET (BY OWSITE 6EHBRAL CONTRACTOR'S E LEGTRIGAL TOR). D. A HOLE 15 TO BE DRILLED AT EACH END OF THE REAR WN.L COUNTER. A BEIGE PLASTIC 6ROMMET WITH AN INSERT 15 TO BE INSTALLED IN EACH HOLE AT THE CABINETRY SHOP. REFER TO 5E'ARATE FIXTURE DWG. TYPE "FI" FOR HOLE: LOCATIONS AND SIZE. E. THE 1/4" FABRIC PADS FOR ALL CABINETS WLL BE MADE UP AT THE CABINETRY SHOP. CACHE IS TO SUPPLY THE FADPJC,. 4, STANDARD MATERIALS TO BE USED A. ALL r4k= _ S'TEPPED SOMITS AIRC TO W 1/4 SAM SLIP MAPLE FINISHED � AS PER, OWib. D. ALL ELL.NOSC MOUL.DIW IS TO W MAPLE FINISHED Q AS PM DNIGS. C ALL SALES AREA SAW 15 TO W PRIME PAINTED BY CABINETRRY CONTRACTORR AND FIELD FINISHED AS PER DWGS. D. ALL FITTING (ROOM BASE IS TO OE MAPLE FINISH W q> AS PER ON". S. CABINETRY: 'SUPPL BY CABINETRY CONTRACTOR FIELD INSTALLED BY ON -SITE GEIEIRAL CONTRACTOR A. RECEIVE AND INSTALL ALL CABINET MrORK, FINISHM MILLWORK, PAN W146, WOOD DOORS, FRAMN:>b, CTG. AS SHOWS ON 014ANN" OR AS DIRECTED. B. CUT AND FIT ALL MILLWORK AND JET PLUMES AND TRUE. Co. MITEIR GUT ALL INSIDE AND OUTSIDE CORNERS. D. SAND ALL SURFAGE5 TO A SMOOTH AND EVEN FINISH. E. BACK OUT FLAT TRIM TO PREVENT WARPING. DRILL AHM N OCeSSAIRY TO PREVENT'5PL.ITTINb. F. FIT ALL DOORS TO LEAVE: 15GUAL SPACE ON ALL SIDES, UNDE:RGUT. 6. CALKING: SUPPLIED BY CABINETRY CONTRACTOR FIELD INSTALLED BY ON -SITE &ENERAL CONTRACTOR A. CABINETRY CONTRACTOR TO PROVIDE A TOTAL OF (10) TWES OF CUSTOM COLORED GAULKINI6 EACH STORE. (6) TUBES TO MATCH PAINT (2) TUBES TO MATCH MV�.70D Q ON�51TE: 6.6. TO 'A" BASE NESTS FLOOR 4 WERE STEPPED WOOD SOFFITS MEET DRYWN.L CONSTRUCTION. RESPON5151LI 1 T SCHEDULE Lmov X FVRGHASED OR SUPPLIED BY Y INSTALLED 13Y PERFORMED BY WA NOT APPLICABLE �1� I TEM k PMMETER CONTRACT REMIARKS 1. DEMOLITION . 2. NEUTRAL PIERS . NA - BY LANDL 0 S. MALL FLOOpjNkS Z 4 M 0 _ W N 0 IN! WA - CAC.IE FLOOFUNL6 TO CLOSURE 4. DEMISING PARTITIONS - META_ STUDS XY 04 WA - BY LANDLORDS CONTRACTOR 5. DEM151NO PARTITIONS - 6YPSUM BOARD XY o n TAPE, SPACKLE, 4 PREPARE FOR N EA Raga- 'L16HT FIXTURES W/ LAMP'" b. ELEGTRIGA_ WORK TO BE SUPPLIED BY "CACHE" M XY INC I TION 4 FINAL HOOK -UP LUDE OF GAS. CONTR. LIGHT FIXTURES (5HC'7MVGA5E5). 1. SPEAKERS AND SOUND SYSTEM X Y W 6. RVA.C. WORK XY q. PL.0 BINS WORK WA 10. FIRE SPRIN ICLER WORK XY II. STO IT C40WT144TION XY INCLUDING 6LAS5 4 OJ4. ROLLINS 6RILL.E 12. STOREFRONIT LIMESTONE TILE X Y 15. WOOD VENEER I6 X Y 14. 51 4 INTERIOR 516NN S XY BY CACHES 516N CONTRACTOR 15. 6YPSW BOARD CEILINGS AND CLOVE XY lu TAPED, 51PACKL.ED, AND PRIMED 16. AC.OUrTIC LAY -IN TILE CEILINGS XY STORA 1! ROOM 1 &YFSUM BOARD PART'N5, FURRING, ENCLOSURES XYJ V4 TAPED, SPACKLE ID, AND PRIMEW 18. PAINTING OF 6YP5W BOARD CEILIN65 4 PART1r5. XY K. SHOW NNOON1 DISPLAY PLATF(X MI'3 XY OEi►\,I* T IJ "hfLL I 20. ALL DOORS COMPLETE NTH MRDMIARE XY EXCEPT AS NOTED 21. ALL MIRROR ON PART'NS, FITTING ROOMS, AND TRIPLICATE MIRROR XY INC.LUDIN& TOP MV DCrTTOM POLOW C+PZ)ME J KX DING 22. PORCELAIN CERAMIC TILE FLOORING X Y 23. CARPET X l FITTING ROOMS ONLY 24. VINYL FLOOR TILE AND BASE XY INGL.UDINS VINYL R15=EIR STRIPS 25. SATIN STAINLESS STL. FLOORING ANL&.ft AND MARBLE REDUCER STRIPS XY 26. SALES AREA RECZSSED WALL STANDARDS X Y 21. FLOOR FIXTURES Y X 20. SHOWCASES Y X 24. GASH WRAP GaNrM Y X EEO. M1000 TRIM AND BASE Y X 31. WOOD STEPPED SOFPIM END GAPS AND Y X $2. 1011OW TABLE / SHELVING UNITS IN STORAGE R 0M Y X W. TRASH REMOVAL AND DAILY GLEAN UP XY PLAN FORMAT THIS GAGES PROJWT 15 DIVIDED INTO TM (2) CATEbf ME'S: I. ON-SITE: GAOLS' TRUGTION PLANS 2. OFF -SITE K.D. FIXTURES TYPICAL. S HOP` DRANNN65 THE ENCLOSED PLANE, ARE OWSITE Wt*TRlr.,Tk;N PL/M, To BE ERECTED Dy THE OWSITE b G. 9045R TO ADOVE ITY SCIM L.E T14AT OUTLINES THE rw.-w- 0NISIDILITHES OF THE LAN CLORD AM C4 ALL OTMt LITY S TMAT OF THE ON-Oft &..G.. TFE C' "TE b.G. MUST COORDINATE ALL M1LJIdC AND TRADES " OFF -'SITE CONTRACTOICS. ON - SITE PAGKA Ko BY ON NIT 6041IRAL CONTRACTOR CCILIN* SYSTEM I. i'1J1l4ISHH AND► INS CEILINIb SYSTEMS 001HPLETE WITH SUSPENSION SYSTEM ANSI RELATED AC4ESOMES AS SHOM ON DRANMN" AND AS 91 2. :SUSPENSION SYSTEM $H ALL W ADEQUATE TO 9IJPPORT LIGHT FIXTUMS, CEILINi 6MLLES AND DIFFUSERS, AND OTHER NORMAL A�E3bORls.. PROMDE SYSTEM 010MINON 10" FROM SINAI S. I NST ALL CEILING AND SUSPENSION SYSTEM IN STRICT AGGORDANGC NTH MANIUFAC1URt:R'S RECOMMENDATIONS. FINISHED GEILINS SHALL BE LEVEL. NTH JOIN'T'S SMUG AND S DARE, AND TILES OR PANELS IN PERFEC WNPITHON. INSTALL 'SECAI,N JTY GRID CLIPS ON FIRST TWO TILE'S AROUND PERIMETER OF STORE. PAINTINS, FINISHINS, AND WALLCOVE FUNS 1. THE INTENT 15 TO PROVIDE A SATISFACTORY FINISH TO ALL PAERTS OF THE PRO.EGT, WETHER NOTED HEREIN OR NOT UNLESS SPIECIFIGALLY STATED OTHERNMSE. COVM ALL SUIIFACaS THOROUSHL IF TIE N *40ER OF COATS 5PL'r�GIFIED DOES NOT ACCOM PL.15H THE INTENT, THEN APPLY ADDITIONAL GOATS OF SPECIFIED MATERIAL TO 61VE SATISFACTORY CCVERA6E. SEE FINISH SC.HEDUI..E. 2. USE ONLY THE PAINT AND RELATED MATERIALS OF THE MANUFACTURERS QrMIFIED. 5- GLEAN ALL SURFA4E°5 TO BE PAINTED FRM OF LOOM DIRT AND DUST dEFORE WORK IS STARTED. 4. PAINTED DRYWALL TO RECEIVE ONE GOAT LATEX PRIMER AND TWO GOATS OF SPECIFIED PAINT. TINT PRIMER TO APPROXIMATE SHADE OF THE FINAL GOAT. TOUGH U' Al SUCTION SPOTS OR HOT SPIO'T3 AFTER APPLICATION OF FIRST GOAT AND BEFC"SERE APPLYINS SECOND GOAT, TO PRODUCE AN EVEN RAT IN THE FINISH GOAT. DRY ALL GOATS THORJOUOHLY BEFORE AP'PLYIN& 51JrCEDINS GOATS. FOLLOW MANUFACTURERS RECOMMENDATIONS FOR REGOAT TIME. SEAL ALL DRYWALL SURFACES BEHIND MI UWft. S. YVA514 ALL META. SURFACES WITH MINENRAL. SPIRITS TO REMOVE ALL DIRT AND 6REASE BEFORE APPLYING FINISH. WEIRS RUST AND /OR SCALE 15 PRESENT, NRE BRUSH OR SAND GLEAN BEFORE: APPLYING FINISH. 6. PUTTY ALL NAIL HOLES, COUNTEIRaW SCREWS, BOLTS, CRACKS, ETC., BEFORE APPLYING FINISH. T. SAND ALL WOOD SURFAiGE5 SMOOTH AND E:VM BEFORE APPLYINb FINISH. 6. BORE STARTING FINISH WORK, R , 10VE HARDWARE, AGGESSORIBS, PLATES, LWITINI6 FIXTURES, AND SIMILAR ITEMS, OR PROVIDE AMPLE FRO IWTION FOR SUCH ITEMS. 4. V4000 DOORS, SEAL BOTTOMS, TOPS, AND ED6M. SAND ALL ft= DOORS BEFORE FINI5HI1§16. 10. MAKE FINISH MrORK UNIFORM OR APPROVED FINISH, SMOOTH, FREE OF RUNS, , AND DEFECTIVE BRUSHING AND OLOG61N S. MAKE E06E5 OF PAINT ADJOINING OTHER MATERIALS OR COLORS SHARP AND GLEAN WITHOUT OVERLAPPING. �► r 1 lORCaLAJN CERAMIC FLOOR TILE ('.SUPPLIED BY CACHE - INSTALLATION BY ON -SITE OW I. POKOEL.AIN GIRAMIG TILE AS SPECIFIED IN FIN04 WAMU E AND RCSPONSIpILITY SGHEGUL.E. 2. INSTALL PORCELAIN CERAMIC TILE USING MC410IMENDW METHMS OF THE TILE CONTRACTORS ASSOr IATION OF AMIRIGA ANp THE TILE COIJNK.IL OF AMERICA, INC. 3. INSTALL PORCa AIN CERAMIC TILE USINS mTE THIN -SET METHOD WITH PORTLAND CEMENT GROUTING MORTAR. JOINTS TO BE A MAXIMUM OF 1/Ib" IN WIDTH AND NOT BE MRREddJ1.AR IN NI TN. 4. CAREFULLY GLEAN ALL WORK AND REPLACE OR RtPDINT ANY DAMAGl.'D WORK AND LEAVE IN POW WT C4WITION. USE NO ACID ASNIT OR MICE THAT WILL MARK SURFACE. SUPPLY AND INSTALL FLOOR GAPE rRiO XICTS AS SPWIFICD IN FINSH 'lNGMRPAZ. S. TILE GROUT LINES ARE NOT TO EXCEED 1/16" IN NDTH. CARPET (SUPPLIED ISY CACHE - INSTALLATION BY ON -SITE OjCj 1. DIRECT SLUE DOM CARPET INSTALLATION. INSTALL AS SFWIFIED IN FINISH S *XXIL.E AND R15PON51ENLITY 50CIPULE. 2. FILL ALL CRACKS, JOINTS, ETC. IN SUB -FLOOR NTH CMWo C FILLER APPROVED 15Y CARPET MANUFACTURER. S. PROVIDE BINDER MARAX*E 5?RIP5 AT EXPOSED CARPET E76M ONLY. DO NOT INSTALL BINDER BAR WERE GARPET5 ADIJTT AT ADJACENT WOOD, MARBLE, OR GERAMC TILE FL00RIN6. REINFORCED VINYL FLOOR TILE I. FURNISH 4 INSTALL AS SPECIFIED IN FINISH SCHEDULE AND RE5PON151BILITY SCHEDULE. 2. 1/8" x 12" x 12" REINFOR W VINYL TILES WITH 4" HHI6H x I/8" THICK., TOPSET, 6avW VINYL BASE. SEE FINISH 5. FILL ALL CRACKS, JOINTS, ETC. IN SUB -FLOOR NTH CRACK FILLER APPROVED BY FLOORING MANUFACTURER. INSTALL ALL MATERALS NTH WATERPROOF TYPE ADH MUVM AS PgroOMMINDED BY FLOORINSP MANUFACTURER FOR MATERIALS AND SURFAf E5 INVOLVED. LIMESTONE STOREFRONT TILE (SUPPLIED BY GAELIC - INSTALLATION BY ON -SITE 644 I. LIMESTONE TILE: AS SPECIFIED IN FINISH SCHEDULE AND RESPONSIBILITY SCHEDULE. 2. INSTALL LIMESTONE TILE U51N6 REWMMENDED METHOD* OF THE TILE CONTRACTORS ASSOCIATION OF AMERICA AND THE TILE COUNCIL OF AMERICA, INC. S. INSTALL LIMMTOME TILE USINS MTE THIN -SET METHOD WITH PORTLAND CEMENT 6ROUTIN S MORTAR JOINTS TO BE A MAXIMUM OF IA6' IN WIDTH AND NOT HE IRREGULAR IN NM. 4. CAREFULLY GLEAN ALL V40RK AND REPLACE OR REPOINT ANY DAMAGED WORK AND LEAVE IN PERFECT CONDITION, USE NO ACID A6ENT OR DEVICE THAT WILL MARK SURFACE. SUPPLY AND INSTALL FINISH CARE PRODUCTS AS SPECIFIED IN FINISH S0*37ULE. 5. TILE &ROUT LINES ARE NOT TO EXCEED 1/16" IN NMDTH. R�lewslN E Cot 1 1 6 1 % ON I Bu w .000 nrry M. A JUN 2 1 2 004 ft%vT C&OU �m a .. p � IN aoA� . W� A . Z 4 M 0 _ W N 0 IN! t 8 x .- N • 0 z wSco 04 W cm 4c 0 o n � c M Z z W 3 lu Z O V4 11.1 _ L •+ OEi►\,I* T IJ "hfLL I STATE ()F iNA iPGT0N 1 DRAWN CHECKED DATE o SCALE ONE JOB NO 051 '3 SHEET ILA-'m OF SHEEN 10 .d�- F7 I 1 Q a ru 6; a 00 0 c tm a 'fl z a I LjL rn c C) a) t LA- u) m or-4 ry) r�o U Q) 0 0 i • Lic s PARTITION PLAN 1 /4" s 1' -0" PARTITION L E6r=N 1:) SYMBOL OfMaptIPTI ON EXIS►r6 7 1 /4 FULL. HEI6HT FIRE RATED MNSINS PARTITION WITH 6' MTL. STUD FRAMING AND 5/8" 6YP. BD EACH 51DE BY LANDLORD. PATCH/REPAIR M9M NECESSARY TO MAINTAIN IHR, FIRE RATING PER UL ftW65. SALES FLOOR ONLY: INDICATES NM R6CCSGW WALL STANDARDS (6' LOW IN STALLED AT +24 "AFF) AT SALES FLOOR. VAIM0Y" ADAPT -A-STUP MAO rM *A! STANDARDS. SQ DETAIL A. DMkS 01" FOR ADDITIONAL x006. WIN flxnm ONLY: INDICATES N IPI RECAMISM MALL 'STAM7ARLOS (4' LOW INSTALLED AT +10 "APF) A A �! AT WtA FIXTURE. "60ftr ADAPT -"7W 400 TYPE "A' STANDAMS. 00 DETAIL A, 01% •I" FOR ADDITIONAL VW6. I. HORIZONTAL BARS 5/I6" DIAMETER 50LIP ALUMINUM ALLOY 5056 H52 WITH ULTIMATE STRENSTH OF 4000 PS.1. VERTICAL SPACING 3" CENTERS 2. PANEL MODULES: 36" x 3" PANELS CONS4STING OF 1/8" THICK CLEAR, FLANS- RETARDANT POLY C 4RBONATE MATERIAL, (LEXAN) 5ECIJRE"D TO NATURAL ANODIZED COLORED NYLON LINKS. COORDINATE AND CONFIRM WITH MALI CRITERIA THAT LEXAN INSERTS ARE ALLOPI D BY LANDLORD PRIOR TO 6RILLE FABRICATION. S. END CHAINS TO LOCK INTO 6L.IDES TO RETAIN CURTAIN ENDS. 4. BOTTOM BAR TO BE EXTRUDED ALUMINUM TUBULAR 5BGTION 2" x 3 1/2" x 1/6" THICK. B. GUIDES SHALL BE EXTRUDED ALUMINUM SECTIONS I/6' THICK MINIMUM, EQUPPED NTH WOOL PILE RULERS. PROVIDE IN'1E6RAL STRUCTURE SUPPORT TEES. TUBES TO EXTEND TO STRUCTURE A OVE FOR BRACING. C. WUNTERILALANi SHAFT ASSEMBLY 5HUVL CONSIST OF STEEL. PIPE CAPAd3L.E OF SUPPORTING CURTAIN LOAD WITH MAXIM DEFLECTION OF 0.03" PER FOOT OF WIDTH AND HELICAL TORS 40N SPRINIS Ac5fi MEILY DESIGNED FOR PROPER BALANCE OF GRILLE TO INSURE THAT EFFORT TO OPERATE 6RILLE WILL NOT EXCEFD 35 POUNDS. BALL OR ROLLER BEARINGS TO BE FURNISHED AT ROTATING SUPPORT POINTS. PROVIDE Y44!EL FOR APPLYING SPICING TORGLE AND FOR FURTHER ADJUSTMENT. D. BRACAZM SHALL BE STEEL PLATE NOT L.EW THAN 3/16" WITH BALL OR ROLLER BEARINGS AT ROTATING SUPPORT POINTS, BOLTED TO GUIDE Afi6EN+8LY EXTENSION. E. HOOD WILL NOT BE REGUIRED. F. PROVIDE FOR CYLINDER LOCKS IN BOTTOM BAR LOCKING AT BOTH i4olBS, OPEIRABLL OUT'°SWE. PROVIDE TM" TURN INSIDE. PROVIDE S16N ON BOTTOM BAR AWoH IN CONTRASTING LETTERS READS ' THIS DOOR TO (REMAIN OPEN I+EN dALDINS IS CX="EG." FIN SI"E5: HORIZONTAL AU" MM M RODS, BOTTOM S Mt AND WM SHALL BE OF AL.UMIR M NT11 CLEAT[ ANODIZED ELEGW45TAM PAINT FINISH. V ItTIGAL MOLDED NYLON LINKS, NATURAL ALUMINUM COLOR EXPOSE FE,lrMA VJWACES PRIMED. INSTALLATION: A. WA -L MANUAL ROLLING GRILLE CURTAIN IN STRICT ACCORDANCE VW TH M N4P## GTUIRE'S mRINm MSTNRLUGTKI m. d. INSTALLATION SHAiL !E 1W A IJTNOIUZED C%j tWOR OR p=mmSWATNE OF THE MANUFACTURE. G. 1'MALL'.' AND CEILING TO W INSTAi1. AIM GRILLE IS EIREGTED. OJALITY INGL RANEE: MIAWACTURE SMALL SI PLY A CERTIFICATE STAT O TMAT ALL MATMALS AND FINN MRLL COMKLY I047M THE SPWAF W im, M. NEW NOMINAL 5 CEILING HEIGHT PARTITION WITH 5 "m (25 6AJ MTL. STUD < 9> FRAMING AT 16' O.G. WITH "" TYPE "X' 6YPSH BOARD EACH SIDE. EXTEND r METAL STUDS TO 9' ABOVE FINISHED CEILING 4 SEC.IIRE VVDIAd;ONAL EIRAC.ING w TO BOTTOM OF DECK ABOVE. EXTEND 6YP. BD. 3 ABOVE TILE CE.ILINIS ON STORAGE 51DE AND TO FINISHED CEILING ON FITTING ROOM SIDE. 4 NE" NOMINAL 5 CELL.ING HEIGHT PARTITION WITH 3 5/A' (25 6Aj MTL. STUD WC FRAMING AT 16' OZ. WITH 5/O' TYPE "X" 6YP"" ISDARD EAC44 SIDE. EXT5V 3 MTTING - METAL STUDS TO 3" A CIOVE FINISHED CEILING i SECURE YMA60NAL BRACING TO BOTTOOM OF DECK ABOVE EXTEND GYP. W. 3" A IOVE TILE CEILING. 5 NEW NOMINAL 5 3/4 TH. CEILING HE1614T PARTITION WITH 2 I/2 ( 25 6A) W L STW �°•� °z '� x a FRAMING AT 16" O.C. WITH 5/a TYPE "X" 6YPSlJM BOARD EACH SIDE NiM REWIRED (SEE PLAN). EXTEND MYL STUDS 4 6YP. BD TO FINISHED OWN& f+ NEW 5 1/6 TH. +10' -4' FEWW PARTITION MTV 2 I%Y (20 " METAL S1UD RtAMNN5 ROM (SPACED AS c OM FOR 050CMIM STPW W/ ONE LAY111! "a TYPE "X' GYP OV. EACH SIDE M IM R GO (SM PLAN). EXTEND METAL STUDS TO +KV -4' IVF IAV DIA6. co) t ... BRAC AS 111125 D. EXTOV GYP. ED. TO F149H UP CEILING. T NM NOMINAL 2 918' TH. CEILINS HEIGHT PARTITION WITH 15J8" (25 6A) MTL STW F'RAMN6 AT 16" O.G. WITH "a TYPE 8 X 0 6YP.itJtM BOARD EACH SIDE. EXTEND MTL REAR STUDS i 61P. ED TO FINISHED CEILING. b NI" WD FIXTURE G0N57RLIGTkXk 9WFL1W BY C 4PNETRY CONTRACTOR / ENTR.I► WTALl W 4 F0.0 FMH W BY ON SITE Ofo. 1QPER TO OtrMQ► MD-O 4 MILLAM Z � SHOP VMS FOR DETAILS. EXIST6 FIRE RATED COLUMN ENGLO•SURF TO REMAIN. PATC.HNIIMEPAIR MW NEC4 5ARY TO MAINTAIN L H FIRE RATING. SALES FLOOR ONLY: INDICATES NM R6CCSGW WALL STANDARDS (6' LOW IN STALLED AT +24 "AFF) AT SALES FLOOR. VAIM0Y" ADAPT -A-STUP MAO rM *A! STANDARDS. SQ DETAIL A. DMkS 01" FOR ADDITIONAL x006. WIN flxnm ONLY: INDICATES N IPI RECAMISM MALL 'STAM7ARLOS (4' LOW INSTALLED AT +10 "APF) A A �! AT WtA FIXTURE. "60ftr ADAPT -"7W 400 TYPE "A' STANDAMS. 00 DETAIL A, 01% •I" FOR ADDITIONAL VW6. I. HORIZONTAL BARS 5/I6" DIAMETER 50LIP ALUMINUM ALLOY 5056 H52 WITH ULTIMATE STRENSTH OF 4000 PS.1. VERTICAL SPACING 3" CENTERS 2. PANEL MODULES: 36" x 3" PANELS CONS4STING OF 1/8" THICK CLEAR, FLANS- RETARDANT POLY C 4RBONATE MATERIAL, (LEXAN) 5ECIJRE"D TO NATURAL ANODIZED COLORED NYLON LINKS. COORDINATE AND CONFIRM WITH MALI CRITERIA THAT LEXAN INSERTS ARE ALLOPI D BY LANDLORD PRIOR TO 6RILLE FABRICATION. S. END CHAINS TO LOCK INTO 6L.IDES TO RETAIN CURTAIN ENDS. 4. BOTTOM BAR TO BE EXTRUDED ALUMINUM TUBULAR 5BGTION 2" x 3 1/2" x 1/6" THICK. B. GUIDES SHALL BE EXTRUDED ALUMINUM SECTIONS I/6' THICK MINIMUM, EQUPPED NTH WOOL PILE RULERS. PROVIDE IN'1E6RAL STRUCTURE SUPPORT TEES. TUBES TO EXTEND TO STRUCTURE A OVE FOR BRACING. C. WUNTERILALANi SHAFT ASSEMBLY 5HUVL CONSIST OF STEEL. PIPE CAPAd3L.E OF SUPPORTING CURTAIN LOAD WITH MAXIM DEFLECTION OF 0.03" PER FOOT OF WIDTH AND HELICAL TORS 40N SPRINIS Ac5fi MEILY DESIGNED FOR PROPER BALANCE OF GRILLE TO INSURE THAT EFFORT TO OPERATE 6RILLE WILL NOT EXCEFD 35 POUNDS. BALL OR ROLLER BEARINGS TO BE FURNISHED AT ROTATING SUPPORT POINTS. PROVIDE Y44!EL FOR APPLYING SPICING TORGLE AND FOR FURTHER ADJUSTMENT. D. BRACAZM SHALL BE STEEL PLATE NOT L.EW THAN 3/16" WITH BALL OR ROLLER BEARINGS AT ROTATING SUPPORT POINTS, BOLTED TO GUIDE Afi6EN+8LY EXTENSION. E. HOOD WILL NOT BE REGUIRED. F. PROVIDE FOR CYLINDER LOCKS IN BOTTOM BAR LOCKING AT BOTH i4olBS, OPEIRABLL OUT'°SWE. PROVIDE TM" TURN INSIDE. PROVIDE S16N ON BOTTOM BAR AWoH IN CONTRASTING LETTERS READS ' THIS DOOR TO (REMAIN OPEN I+EN dALDINS IS CX="EG." FIN SI"E5: HORIZONTAL AU" MM M RODS, BOTTOM S Mt AND WM SHALL BE OF AL.UMIR M NT11 CLEAT[ ANODIZED ELEGW45TAM PAINT FINISH. V ItTIGAL MOLDED NYLON LINKS, NATURAL ALUMINUM COLOR EXPOSE FE,lrMA VJWACES PRIMED. INSTALLATION: A. WA -L MANUAL ROLLING GRILLE CURTAIN IN STRICT ACCORDANCE VW TH M N4P## GTUIRE'S mRINm MSTNRLUGTKI m. d. INSTALLATION SHAiL !E 1W A IJTNOIUZED C%j tWOR OR p=mmSWATNE OF THE MANUFACTURE. G. 1'MALL'.' AND CEILING TO W INSTAi1. AIM GRILLE IS EIREGTED. OJALITY INGL RANEE: MIAWACTURE SMALL SI PLY A CERTIFICATE STAT O TMAT ALL MATMALS AND FINN MRLL COMKLY I047M THE SPWAF W im, M. r DOOR SCHMDUL E O ENtrRY _ FURNISHED AND INSTALL MODEL V36: OvEmeAD MAN UAL OPERATED ROILING GRILLE CURTAIN AS MFR. BY METRO DOOR. q1 SMITHTOM BYPA56, 2nd FLOOR, HAUPPAUk5E, NY 11766 WOM4. 366'1 EXT. 258; ATTENTION MTN KRANTZ. RE3 TO DRMN6 10-5. MATERIALS: A. GRILLE CURTAIN CONFORMING TO THE FOLLOWING. D OOR SCHEDULE REVIEWED FOR CODE COMPLIANCE APPROVED JUL 13 2004 City Of Tukwila BUILDING DIVISION FITTINkS - 2'-6' x 6'-8 x 1 3/8" TH. HO WOOD DOOR W/ ND CASING NNDERGUT Z ROOM DOOR 1 "). FIN. DOOR 4 FRAME R . 1 1/2 PAIR STANLEY 4" BUTT HI NFrEZ 4 FLOOR r STOPS SATIN 5T. STL 04 FINISH. "5C LA61E" 5 SMES JUPITER LEVBR STS w FUNCTION LOCK SET (ALL KEYED ALIKE) FINISH 626 SATIN C ROME. DOOR 4 r • WC 3' -0' x 6' x 13/8' TH. HOLLON WRE 1 DOOR YV WD CASING 11ADERGUT 3 MTTING - DOOR 1 FIN. DOOR i FRAM 0 1 I/2 PAIR STANLEY 4" BUTT HINGES i FLOOR r DOOR SCHMDUL E O ENtrRY _ FURNISHED AND INSTALL MODEL V36: OvEmeAD MAN UAL OPERATED ROILING GRILLE CURTAIN AS MFR. BY METRO DOOR. q1 SMITHTOM BYPA56, 2nd FLOOR, HAUPPAUk5E, NY 11766 WOM4. 366'1 EXT. 258; ATTENTION MTN KRANTZ. RE3 TO DRMN6 10-5. MATERIALS: A. GRILLE CURTAIN CONFORMING TO THE FOLLOWING. D OOR SCHEDULE REVIEWED FOR CODE COMPLIANCE APPROVED JUL 13 2004 City Of Tukwila BUILDING DIVISION FITTINkS - 2'-6' x 6'-8 x 1 3/8" TH. HO WOOD DOOR W/ ND CASING NNDERGUT Z ROOM DOOR 1 "). FIN. DOOR 4 FRAME R . 1 1/2 PAIR STANLEY 4" BUTT HI NFrEZ 4 FLOOR STOPS SATIN 5T. STL 04 FINISH. "5C LA61E" 5 SMES JUPITER LEVBR STS w FUNCTION LOCK SET (ALL KEYED ALIKE) FINISH 626 SATIN C ROME. DOOR 4 FRAME C WL.ETE W/ HARDWARE SUPPLIED BY CABINETRY CONTRACTOR, INSTALLED BY ON SITE &C. WC 3' -0' x 6' x 13/8' TH. HOLLON WRE 1 DOOR YV WD CASING 11ADERGUT 3 MTTING - DOOR 1 FIN. DOOR i FRAM 0 1 I/2 PAIR STANLEY 4" BUTT HINGES i FLOOR STOPS SATIN ST. STL 04 FINISH. "5C+1 LA6E" 5 SERIES . UPITER LEVER STOREROOM W N 0 FUNCTION LOCK SET (ALL KEYED ALIKE) FINISH 626 SATIN CHROME. DOOR i �°•� °z '� x a FRAME WMPLETE W/ HARDWARE SUPPLIED BY CABINETRY CONTRACTOR INSTALLED BY ON SITE 6ja. STORAGE - 3' x 6'-8" x 1 3/4' TH. '8" LABEL FIRE RATED H.M. DOOR 4 FRAME. FINISH FITTING ROOM SIDE OF DOOR PLAST. ROM LAM. O MRON'IDED BY ABINETRY Or C11RAGTOR). FINISH STOCK ROOM SIDE OF DOOR 4 FRAME 4 . co) t ... 2 PAIR STANLEY 4" BUTT HINIGES SATIN 5T. STL *4 FINISH. 'SC+LA6E 5 SERIES X in V sin JUPITER LEVER PASSA6E SET, FINISH 626 SATIN OftON WINCEALED OVERHEAD SELF- AUTOMATIC, DOOR CLOSER 'LEN SUPER SMOOTHIE' ON CORRIDOR SIDE. REAR EXIST'& 3'-O' X '1;§, X 1 3/4m 0 0 0 LABEL H.M. DOOR AND FRAME, PAINT IN51DE S 5E - D'OOR i FRAME PAINT EXTEMOR DOOR / FRAME t PROVIDE 516NINS AS ENTR.I► PER LANDLORD POW( REPI TS. ON SITE 6.C. TO INSTALL THE FOLLOINNG ITEMS, Z � IF NOT EXIST6: • OVERHEAD AUTOMATIC DOOR CLOSER ON CACHE SIDE OF DOOR (IWVW "LCN SUPER 5M00THIE" OR EQUAL. • FIRE EXIT DEVICE YV SATRRY ALARM BY "DETEXO OR EGIUAL. • CWAPI.OGK -EILAN K FACE PLATE AT GORRRI DOR 51 DE, oc W PUSH BAR UPERATED AT INSIDE. SELF LATCHING FEATURE W*EN z DOOR 15 CLOSED. C-ONS T1 1 11ICTION NOTES- 1. ON SITE O.C. SHALL VERIFY ALL FIELD C.ONDITIONfi i SHALL HAVE SOLE RESPONSIBILITY FOR VERIFICATION OF CLEAR HEI6HT5 S FLOOR I7EFRE551ON5 UMITHfIN THE BASE QJIL.DINS. 2. ON 51TE 6.C,. PRIOR TO ERECTING ANY NEMI PARTITIONI5 TO FIELD SURVEY t COORDINATE ALL CLEAR DIN+EN510N5 N CABINETRY CONTRACTOR TO ENSURE PROPER FIT OF GAMWMORK Il FIT. FMS. - I Heft IS NO MAPAHN FOR ERROR, S. ON 51TE O.C. TO 1lEPER TO V Mb 010 -6 FOR ALL DRYMALL / MOM GAP DETAIL'S AND 0ONDITION9. 4. ON SITE O.C. TO APPLY N em FIRE GAUJLKINb ALON S DEMISING VO4LLS OR P'ATGM/REPAIR EXISTING FIRE CALULKINS. FIELO VERIFY EX ISTING C-OI0DIT)ON. PRIOR TO: CLOSING IN ENTRY COLUMN 5 , WL.DING SH TAI PMN POn PLAr%M45, INSTALLING TILE M.XXMN& i PRQ�IItAELY AF'1t!! ALL SAAL1S AREA FW00CW NIT LIGWW MAS BEEN MTALL.CD - THE ON SITE oz. IS TO CONTACT: "WOMPRO ATTN: RIcMAM SOVeRanS PM: eee- 0- 46W TO COCfRP ATE S6GURIT'1' y1'+bTEM INL4TALLATI4M 0CM FLG M i IN ENTRY SOFFIT. .0,0 f vrv, "^ r JUN 2 2004 AMT cftru REVISIONS - in 4 c gn Z w a ` N N r Z a w � K ..� �► w ��n h V1 � z i W N 0 �°•� °z '� x a �"' b N V 2 • W d , N A * co) t ... X in V sin m � Z Z � W oc W z W V H Q C . 0 a C r z � IL x • a W a �t 0- Z CIL 6600 --�. -- TACT _ DENNIS T k4TCIfcLL STATE OF WASWriN �i DRAWN CHECKED AT SCALE AS NOTED JOB NO. 031 13q SHEET I OF SHEETS is of ". 4..' v 0 0 cv v �r cn 0 c w cy+ s 'o Z CL J rn m 0 r rn r►� 0 r sn v a� 0 r 0 N • r TYPI &� TYPE 'HI FITTING ROOM 6ARMEN17 HOOKS TO BE MOUNTED AT +5'-6' AID. 6.C. TO INSTALL H©RIZ. WOOD BL.00•KINS BEHIND? 6YP. B0. AT ALL HOOK LOCATIONS. I~ I XTURE / FLOORGOVER I NG PLAN 1/4' e 1 --0" NOTE: ON SITE 04. TO PAINT WALLS IN STOCK R)OM N (2) GOATS OF PAINT OVER (1) GOAT OF PRIM M Q CACHE ENTRY Ai 8'H. HOOD FINISH iwiaOX ABOVE TO CEILINIS ALL MIRRORS SHOMW AT FITTING R (H), FLAT MIRROR UNIT, 4 5 WAY MIRROR UNIT (IMGLUDING TOP 4 BOTTOM POL.15HED C IROME J MLD6) ARE TO AE SUPPLIED 4 INSTALLED BY ON SITE &I OVERHEAD MANUAL OPERATED ROLLING 6RILLE O RECTNFIM PORGB.AIN GER/IMIG FIELD TILE Ib "x I6'x 5ma ON TWIN SET INSTALLATION SHIM / FEArrQt WM TILE SO rAAT ALL FINN*ft ALIGN ON SITE 6.0. TO FIELD VERIFY 2 4 EXISTINO MALL PLAPM GOWITION. ALL NDN PINISM PL gXWJN6 TO ALIGN FlITM TOP OF CXISTINS MALL I'L OORINO. I I LEASE LINE 4 FLOORIN6 DETAIL FULL sin A ... WWI . . . II I I I/81W. SATIN ST. STL BY OZ. • FLOORING SY ON 51TE 6.C. Iallllt•• SATIN ST. STEEL. FLOOR.IN116 A?*" 1/6" x S/8'N x I I/2 "L. (By ON 51TE 64i 10 bL.IJC -*OMW CARPET MA EDGE CARPET SO THAT ALL FINI5FE5 A _' r— ALIGN FLOORING DETAIL FULL SIZE 1 1 IP,zldW,I" '-2�IU RECTIFIED POIRGIg.AIN CERAMIC TILE I6"X Ibox 3/Ib' ON THIN SET INSTALLATION SHM It FEATHER EDbE TILE 50 THAT ALL FINI% ALI6N TOP OF C.OWGRETE SLAB J_ I r�! 40 ON SITE &C. TO FIELD VERIFY EXISTING CONCRETE SL0EI CONDITION. MODIFY SLAB TOPPING AS RWV. TO INSURE A UNIFORM FLOORING TRAN5IT'ION THRU -0UT SPACE. FLOOR FI NISH 5CHEPULE (D CARPET %WWAN C:Oh IMC IAL" STYLE: LA BOUCLE, No: LBE, COLOR: 102 DUNE 11°IRS. ON1., WIDTH: 12, TUFTED / ULTRA NGE DUPIONT NYLON CARPET. 02 (CLA65 1 FLAME SPREAD MATINS - FLAMSMIHILITY: MEM OR EXCaWS► Do MV REGUIIEITS FOR NFPA CLASS 1, SMOKE DENSITY: ASTM E662 -450 M OR LB56). TRLP. MR wGARPET SUPPLIED BY GA c FOR DIRECT Sue DOMW INSTALLATION Pl BY ON-VTE S.C. PqRca I6"xlb"x5ft" (RECTIFIED PORE, MAJN CERA"IG TILE, COLOR: LIME 50A. c4p.* IIG (AST" CUM - C.OERFIGIENT OF FRICTION: DRY N6OLITEsO.14, FLooptH'N' MET NEOLITEmOhO, MAT'S OR EXCEEDS ADA SLIP COEFFICIENT'S FOR PG, CERAMIC FLOOR TILE). P9 TILE TO BE INSTALLED IN A PATTERN AS INDICATED ON PLAN. m 61 OUT SPEC: 1/I6' NDE MIA (MUM ,JOINT "MAPE KARAPDXY IN STAINI! EPDXY, GROUT COLOR: ALMOND. 02 INSTALL FLOOR TILE PER MFG. INSTALLATION INSTRUCTIONS. M WM PLETEp FLOOR TILE INSTALLATION TO BE VACUROW 4 LkSHTLY PIL! GAS. MVA M NV VINEGAR 4 04ATM '*TILE 4 6ROUT SUPPLIED BY GAGFE FOR THIN-SET INSTALLATION BY O"TE 6:G. TILE 4 6ROUT AVAJLABLE FROM: 'IMOLA", MIAMI, FL.ORJOA OMPJM -0054 EXT. 112, ATI 51M4. IXA E. vwm 12 "x 12 "x 1/6' VINYL FLOOR TILE 'AP MSTRONIS' STANDARD EXCAELON 0 FLOOR 111 DOLOR 031801 DESERT BEIGE. DA 4' "NW BASE ',ATE' SGBd4 ALMOND. (Q.A96 I FLAME SPREAfl RAT** - FLA044WLITY: NESTS OR EXCEEDS Ifl FOR WPA "ASE I, SMIOM DENSITY: LESS TN" 490) *VIN'Y'L fi.OiOR 4 DAgE 'SWPLIED 4 INSTALLED BY ON 'SITE Or*. L POTONE 10' x 10' x M/16' C440 FMA HOW FHSHIP LIN!'STO C TILE TILE *TEE'SPK= BY GAGIE, METALLED dY ON-WE Of.. fST4 1 : - m4 m I') TU AVALI MWK VA STOM GRAFT MAIIKE 4 STONE, MG.' HN4, MAMA H p c p " SR2- 5429, An% OM SGWE c Z NOTE: I STALL ALL TU CUT a SM AG, Mn ON STOIlEI'110NfT M"ATHLUN6 0� 3 MST#" ALL TNT 1'9TN UI6' K KAX GRA1f .JOIIfi'S. ALL G1lT'SIDE G40M � ~ V 00101TIONlS TO a m" JOINItY PW 11011D mmom v4now llb. Z IL ID. � LIiMTLY ft ft" LINlSTONE 06TALlA" IMTI4 YPI* R MD F%TER Q M �/ cb MAST: '.AW SAM= AR MOIST, COLOR: AWW TRITE 1-600-626-1 9EAI.rR+ 91ftY NV WTftL. FM Nfi 9lJA A CLEAR FEW IRATII*NAM W Ift-AL.M GMOK'E 6 &XV) Ad Iii er 'AA1A N4X MG.' NO 1 146 -1 0 If INDICATES PULL OUT 6AI 34W HOLDER Wo. AT W-a' APP. AT EACH INTERMEDIATE DIVIDQR UXATION TO M SUPlrL.IED BY �CrAONNETRY GONM 4 INSTALLM BY 04. - OM C.OM. TO GOOMINATE PULL OUT HOLDER INSTALLATION W/ GAdNNETRY CONTR. ®V'INYL cowoSITION FLOOR TILE TOP OF EXiS FLOOR I NIS DETAIL F" SIZE G LEMx LIM 6" M. DISPLAY PLATT" CORM FIT`ENN& ROOM "N+�RGER" IMPERIAL WE REDUCER STRIP STOCK No. COLOR No.201 BROM'N IOGARPET -7 IIIIIIIIIIIIIIIIillllltllllluu�� ..__ FI INDEX SYMt3OL. DESGRIPTIGN DI FITTING ROIOM HOLLO11 CORE HOOD DOOR 2'-6"K x 6'-1 coMPI TE VV HOOD FRAME a wARDrV4M (PURNIS E'D BY GAB. CONTRACTOR 4 INSTALLED BY ONSITE &I - 5M DOOR SCHEDULE ON DHGO ID-3 02 FITTING ROOM HOLLOH CORE V400D DOOR 3 1 -oVt x W - C TE! YV HOOD FRANC 4 HARDIA4ARE 1MMSHED BY GAB. CONTRACTOR 4 INSTALLED BY ON51TE 6.CJ - SEX DOOR SCI#Z7U.E ON 0101160 ID-S Do MV LAMINATE ATE - APPLIED TO FITTING (ROOM SIDE OF DOOR, (LAMINATE FURNISHED BY GAB. CONTRACTOR +! INSTALLED BY ON SITE 6.0) - SM DOOR SCHEDULE ON DMVEs4 ID-3 FIT. RM. PACKAGE - WOOD DOORS 4 PIRAMIES (WMPII El E VV H•IDMJ BASE, LIOHTBOX, BENCH M FLAT MIRROR UNIT (SIZE VARIES - IB" MIN. WIDTH) MIRROR BY ON SITE 6.G. TRLP. MR TRIPLE MIRROR UNIT, MIRROR BY ON SITE O.C. Pl SIDE SHOMIGA5E LIFE: W/ GASH WRAP UNIT, REAR WALL COLWTER P'Z FURNITINRE - NESTINdr TA ILES 011,1RNISHEAD EST CAC+0 P4 FLOOR FIXTURE - DREW UNIT (1 DY GAGII ps FLOOR FIXTURE - T -STAND (PUT RNIISH#D BY GA WJ PG, FURNITURE - FITTINiS ROOM STOOL (FUIRNISIED ISY CACIEJ P9 TOI"ER UNIT VV hHNSW DOOR SUPPLIED dY GAD. CONTIt., INSTALLED 15Y ONSITL 64. (REFER TO CAD. SHOP 010465 FOIR DETAILS. SHELVES 4 MANS RODS TO BE INSTALLED BY 6,G. m OIENiT NOOK (PURNISFED BY GAG4W MTV AT +5' -6 ON MOOD DISK IN DESK 4 CAD. - 2'-O"0 x 4' -O"L x SO"M SUPPLIED BY GADINETRY GONTRAGTOR 4 1 NSTAL.LEO BY ON ISI T11 O.C. 02 TISSUE! PAPER UNIT 21'0 x 90%, SUPPLIED BY CABINETRY CONTRjW.,TOIt 4 INSTALLED BY ON ISITE 6.C. M I■IANOIN O / SHELVINb UNIT Ib"D x LOOTHS VA$tY, SUPPLIED BY GAbINETRY CONTRACTOR 4 INSTALLED OW ONISI TE O.0 . PIL! GAS. 4 DRAWER MTL FILE CAlNNET, SUPPLIED BY GAGIE 4 INSTALLED BY ON SITE o.C. 0000� tin► ��o jUIV 2 a 6AC,4C SUPPLIED 6ARNENT ARM. INSTALLED BY ON SITE 6.0. SEE CABINETRY SHOP DWS*'. REVIENED FO CODE COMPLIANCE Jul. 13 ZQ04 pity � �I�wll� B BUILDING 1D) N 60 N. MVL.AY MA"VW LeAMe L IM EXTEND CACHE! FLOORINGTO LEASE LINE O -- G INDICATES STARTING POINT FOR GAC1E FLOOR FIELD TILE REVISIONS0 DRAWN CHECKED DATE SCALE A5 NOTED JOB NO. 03 i � 3q SHEET OF S► -+SE'S • 44- • O r � N Q O � C� er�r z �N J : �% J its 0 x Tj W W q+r 3t go f � J I i n C4 • ob ID 4 Z z W Ifl cc z ul H p c p c Z 0� 3 � ~ V Z IL ID. � Q M �/ cb W U . I- cc OL z %D w L � U X I O tL PH�1;`CT f DENIMS t 1STC!ca STATE Of MIASaI�1 DRAWN CHECKED DATE SCALE A5 NOTED JOB NO. 03 i � 3q SHEET OF S► -+SE'S • 44- 1 v 0 0 clu cu ai to q c c s s rn en .., m cu LA- rn v O f� i b � luWa PA-Ak= wii a (Z WdLWA1 1 .VI.,u. ALL PIEGCS GUT FROM Ib "xlb "x+1/16" TILE. PIELD GUT WIDTH AND HE16HT AS REQUIRED TO SPIT AND BLEND IN AS SHOWN ON NATION. ALL VERTICAL i HORIZONTAL JOINTS TO IN I /16" ". dROUT JOINT. ALL - 1 T C.ONSTRUCTION SHALL BE "SELF SUPPORTING' FROM I'M FLOOR t 1NDE 04DAW FROM THE MALL FASCIA, BUT MAY BE BRACED FRX)M THE MALL STRUCTURE FOR LATERAL SUPPORT ONLY. STOI FRONT ELEVATION FACING OUT FRAM 18"xS"W16 TH. TILE INSTALLED IN PIECES AS SHOWN SCALE. I/2' = 1'-0" W/ IA6 W. MAX. 6ROIUT .JOINTS. EXISTING DEMISING WALL 6 I I 4 h EXISTING, NUETRAL PIER TO REMAIN PROTECT AS 464WRED NEVI DUILD -OUT TO MATCH EXISTING N ETRAL PIERR COOK WITH L.ANLORD. !GAILO, 1 • I'-" I= SA TIN STAINIM6 STEEL M4 FINISH. 2"W. x 2 1/2V. U SHAPED REVERSE C+ W#4 L I P"M "M wITM MUTE WPM RAtAc LIAWrIAli_ I FTt TO W I•N IdG1&n'M In UPON RECEIPT OF LIMESTONE TILE: 6ENERA. CONTRACTOR TO COUNT NUMBER OF TILE PIECE5 RECEIVED, CHECK TILE FOR UNIFORMITY (SIZE s THICKNI!55), FI VERIFY THAT G ANTiTY SFNPPED WILL BE SUFFICENT TO COMPLETE INSTALLATION OF STORffW4NT 4 S OV4 WIN D004 PLATFORMS. ADVISE GAI M PROMPTLY OF STATUS... - 4 1/4 6 5/4" IwM TUBE EN CLOSURE (FOR MANUAL OPERATED ROLLING 6RILLF CURTAIN) COV'D. W/ SATIN 5TL5 5TL BREAK MTL. 0 m.1 EXISTING NJETRAL PIQR TO REMAIN PROTECT AS PZGVMRED SECTION li � I'-4t ' 1'-41 w EXISTING MALL L WWr COVE a lJULKMEAD TO REMAIN RELISH TO LIKE N!W 00WITION BOTTOM OF MALL LISHTOOX • 14 APf NEW CONTINUOIMS 5/4 90. METAL CHANT EL FAINTED TO MATCH LIMESTONE SLOPED GYPSUM DOARV SOPPIT (BEHIND 6LASS) PAINT FINISH 5 ('TYPICAL AT DOTH S1 TYPICAL INDICATES 6YP. DD FIXTURE DIVIDER EONND •LAM& F INISH HOOD SIR I6 (`TYPICAL. AT BOTH SIDES). E ST'IN6 MTL. CHANNEL MALL NWMAL PIER 1R8°1ARBISH TO • LICE AE" CONDITION ". TYPICAL AT BOTH SIDES OF STOREFRONT. 2" HI6H CI)T-OUT BRU5FED ALUM. LETTERS A "-IED TO BACK SIDE OF 6LA5S BY CACFES 516N CONTRACTOR ('TYPICAL) INDICATES RAISED 6' H. PLATFORM (BEHIND 6LA5S) C40V BRED PV 16" 5Q. LIMESTONE TILE E QR. TQ IWT 6LLA M0 OF LIMESTONE TILE: 6EI+ERAL CO111"rRA4TORS TILE % TOR TO HAND PICK TILE FOR COLOR UNIFORMITY t SHADING, CULL THE DARKEST, I.ARLY COLORED OR ANY OSJMTIONABLY MARKED TILES TO ACHIEVE THE LIWIIEST, UNIFORM LOOK POSSIBLE. ADVISE CACaE IMMEDIATELY IF ADDITIONAL TILE 15 D TO INSTALLATION. EXISTING DEMISIN& WALL EXISTING COLUMN � 6 9/6' ( 20 " MTL. STIR PRAMNNO AT 16 W/ DIA00NAL OR041NO AS YAM) SECURE STOlt"ONT 4"TRU4TION 4 ALL SOFF / r e CEILING SLP1 T TO ROOF Jowl NV ADD1. OTEEL FRAM AS RCdt'D. DSO NOT ATTACH T O A" De"A AeaVC EXISTING DLD'b. STEEL i M OCoN. FL.ATrOIIM TO PIDWN • SUSPENSION SYSTEM AS M F6 VY US6 INTERIGRS "0 X' - DONN SUSPENSION SYSTEM OR EGIUAL SECURED TO DOT. Of DECiK ABOVE VV VERTICAL HAN *M WIRE NI ON REFER TO SaGTION DETAILS p ON DWG ME -Z. I Q n TYPE 'X• 6YP DD PWiH PAW i f 5/6 TYPE 0 X 0 GYP. BD SOFFIT PAINT FINISH 0 4 11251 6 5/4 MTL TUBE ENCd.OSURE (1-DR MANUAL OPERATED ROLLING 6R.ILLE CURTAIN) COV'D. W/ SATIN STLS STL BREAK MTL. O 1/2 CLEAR 7EMI •LASS PANEL 7r SECT I ON 1/2' a 1'-0" I 5 5/8" (20 6A) MTL. STUD FRAMING AT 16 0 00 W/ DIAGONAL BRACING AS REVD SECURE 5T PONT CONSTRUCTION i ALL SOFFIT / CEILING SUPPORT TO ROOF JOISTS W/ ADDL STEEL FRAMINS AS REGID. DO NOT ATTACH TO F420 DECK t EXISTING BLOW STEEL. i MEGA. PLATFORM — TO REMAIN • t 4 n TYPE " X • 61 P w FNRSH P/1MIT 4 RE-� � CODE �M� A ppROVEO au� � a zoos I g� �DIN� p� — EXISTINS MALL CEILING AND BULKHEAD TO REMAIN EXISTING MALL LW*IT CAWE AND BULKHEAD TO REMAIN ar � REMpVE EXISTING LANDLORDS MIRROR BARD 1 I I 4f I I I I • I I ILLIUM. 51" 8 10-6 S/8" TYPE 0 X 0 6YP. DD SOFFIT PAINT FINISH 0 4 O INDICATES CENTER LINE OF MANUAL OPERATED ROL.LNMdr 6RILLE CURTAIN AS MFR BY METRO DOOR. 8100*101 1661 EXT. 2546 ATTN. BETH IQVANTZ 1/2 CLEAR TEMPtNIED *LAW PANEL. i u 41 EXISTft MALL GEILIN& AND BLLKWAD TO REMIAIN EXISTING MALL L16W COVE AM DULIOCAD TO REMAIN REMOVE EXISTING LANDLORDS MIRROR BAND ADJ. METAL HALIDE *,SHOW MN DOA TRACK LIQWNTING ON S CEILING MTV 'TRACK LIMESTONE TILE I S✓8 r " TYPE X" t 17- GYP. 10 S PAINT FIN15H 3 • LEASE LINE LIMESTONE TILE O REVISIONS BY r � � IF D ID-6 A ID FLUSH 16' x la' ACCE56 DOOR MTV IN ENTRY SOFFIT. "LCOR' STYLE AIR MV CYLINDER KEY LOCK. FIELD INSTALL 6YP°SUM BOARD FACING t CASIN6 BEADS. FINISH TO MATCH SOFFIT. TO SERVICE ROLLING 6RILLE (ADJUSTMENT TO WHEEL. 4 MW AND 'SM AW. ICI: LIMESTONE TILE I 4 JUN 21 20 04 Oq 4 IA O • � N Z 0 W U1 .I x N^,l a +2 �.. W N 0 = I- 0 low w W • ZEW ew =N .$44v in y r c 2 0 Z W W Z W V H 0 c to ♦0 .S t 0 �3 Z - • IL 0 • _ca D W GROP IL H �r Z z a - I ." XX a ~ r yr STAVE OF WAS}!SiGTON DRAWN CHECKED DATE / p S ALE AS NOTED JOB NO, 05113 SHEET OF SHEE T'c r r f� in i 4 .ea vw.T `A'". "~.Iw. 4 STOREF PLAN v cu 0 to rlu L'ri UD 0 d r 3 N n rS. rn r� b r m a 0 — ._._ _ - ----- 1 I 5 M" (20 6N WL STUD FRAMIN S i I 9 Mo (20 6A) Mn. ----I, STUD FRAMINS 15V (20 " MTL STUD FRAMINIS " rM • X" 6YP. w 5PRAYED ON FINISH C RECz5a D 5/6" MTL CHANEL. PAINT O MAIN S M BY U" 6 IN 511".�1"LNWC SWARM (9 6A) TO ADDL STt r 140 nET + 14' -0" APF SATIN S STEM 44 2'W x 2 1/2"V REVERSE SAN Wv V*M NEON BACK LWIRTING LIMESTONE 0 LMESTONE FAGINIS V LEASE LINE EXISTINS MALL LIOW 004 AND VAXNCAP TO REMAIN I wb' TYPE "X• GONT. 5/4 MTL C ooft q REVEAL, PAINT 6YP%l M BOARD TO MATCH V N � � Z i I ::. Wh � q N LEAS LI I -4 &D TYPE "X' z � � o _ .. oc a HONED FINISH GYP BD I LIMES I - PAGING O I ° L.EASELna I I . I ■ •i m MANUAL. 0 !!IRA'TW RDLLIN& SPJLLE C MItTAIN AS M RL BY METRO POOL OOpAWAW C)(T. 2M ATM WTN KIRANTZ STw MAN" PAIR POW ® _ T — — STUD MtAMNi .. . - W-t7" A FF� I/2 CLEAR PAINT PIN U O S W (20 &N MTL TOW. GLAGS OWSM 1 MTL 6LAZIN6 STUD FRAMINei O O C+wm., SATIN ST. STL PINTS" o O O CAC HE �r• ENT RY 'YE5TI BOLE Y TH TYPE ' X" GYP. BD, PAINT FINISH a _ 14, +W-0 AFF CACHE VETA I L 3" x I , -0 " Ci► 101/4 ■ (2) LAYERS S/D" TH I/2' GL �• �• INONDERDOARP TCI 6L.AW N LIMESTONE 0 1 5r (20 MTL TILE STUD FRAMN6 . �iI► 4" METAL PRAM ft SW TYPE V 6YP. BP (20 ON AT Ibb�G. PAINT FINISH O ALL LIMESTONE TILE FOR ALL LIMESTONE TILE 4 4 112' -C 6 5/4 MM TIC IENIC CURB TO BE (MORJZONTAL # VERTICAL) (FOR MAWAL Ol" a t^TED ROLL.INkS 6RILLE VV MM Vlb'W JOINTS TO AL M MV TOP OF CURTAIW COV'D. W/ SATIN STLS STL 60%W JOINT• PLATFORM FEL P TILE JOINTS. BREAK MIL. D E TA I L. ENTRY VEST I MULE so )10 TA I Lr SM 1'-O" H:*W FINISH p EXPOSED SGIUARE b v ENDS NV 1/16" MAX 6ROUT JOINT '•••• '•••• SOMEONE 011001111 LIMESTONE FACING 4 v I SET DN THIMMT I �r 1 1 / * 2 r oMP�` cna� SID &Y A" BOARD p ►p'�� LIMESTONE FACING (4) SIDES SET ON THICKSETN� oat MTL. STUD (20 6A) FRAM INS kT 16 DEG.. SEC AM TO DOT. 7F BULKHEAD AOOME W TYPE "X" " BD .IMESTONE WAND W.L METAL. HAL IVE SHOW IN POW TRACK LW*nlWG 7N CEI LINS MTV TRACK 2) LA 1 y �•' "a TH rYPE "X" 6YP BD 12" MTL 'OHMS ABOVE NL.AZING 000CLS NT 24 (TYP) .IN�LSTONE 0 r A4 , 1146 SATIN STA%JW 6MM 04 A-1 MIN TOP OL.AZIN & "ROUS" SHIMS TO CONfT. 4" MIL. bIUPS IV M N. FAST06M. .AI' -O" AM LZ Lft • 7 1PETAIL 1 1/2" • I y 5/9" irfm "X" EXISTTN, GYP. BD, FINISH O D "I TYPE "X• GYP. BD PARTITION I ON I "• MTL STUD -- F�INb, PAINT 0 I OEAM CA AW AM) C STRAIN ,l� t�erAlN�e1e sTrtAl�) S/D" 61T. w GEII.ING REFER TO CEILINS DETAILS ON & SE -2 FOR SEISMIC BR,AGINS I I S " (20 6A� MIL. STUB FRAMN6 I I EXISTINS NUETRAL PER TO ORMA1N P1IOTEGT AS ItEi'S,l111ED MN BUS.D -OIJT TO MATCH EXIST M NUET RAL. PM COOK NTM L AOL4 IUD. EMT* STNIUGT. SAM 1•SQ MTTL 61.IWN6 C W#O.. SATIN ST. STL FINISH. 4 &16" MIN. FACE CLEARM" VV NEOPRDE SPACM AND GEAR M 1116' NOMINAL BITE MINI ' WW MIN WOE CLEARANCE PROVIDE SETTING BLOCKS NOT LE56 THIAN 4 ". CURB FACING - CUT FROM UMESTOW TILE U4 16" x 16" x I/2'TH SOLID BLOCKING SECURED TO SLAB M AU nk FLOOR *J/O ALL TFI4VAP` " SADDLE NUT c►�r► -F� u�ISTwr 12 6A V0tTIGAL HIRES 4'-O' O.C. BLACK IRON --t 1/8 METAL HAT C.HANEL BRAC►' I N6 DETAI AT 5TRUGTURAL BEAM5 FOR 5U5PENDED CoEILINC75 TYPICAL I OPEN .JOINT ! 4 " I I I 1 1/2 s 1-O (:7 r WORD GAP, WOOD Q RIS TO DETAIL A, DWb •ID-a. ' TYPE 'X' 6YP. BD, WC70V VENEER LIMESTONE FACING SET ON TNI .VJET 0 IIDMG�LTCS -- STOIQlNONT ++EAVM • V -2 1/p" APF I/2 C4EA t I 7°"P. 6LA6e F& c*Nf W„ MEOW c"'MR wb' TYPE "X• .. p q w 6YP%l M BOARD N V N � � Z i 41 Wh � q N � -4 I z � � o _ .. oc a HONED FINISH �z� V r � `N I "'• uno qf !! cc 0 3 VON = N 9L EXP0,5m SQUARE EXISTING MALL LIFsi'IT G4 Vn o *4" wam cc GINNIE AND E U XW_Ao TO RIENUVN z MAX 6RDM JOINT 1/8" DE IE D T I I~ W TYPICAL PLATFORM � V TYPICAL OUTSIDE � H 0 as FULL. SIZE EVOE DETAIL ca C c FULL SIZE GOR1NR DETAILS X14' -O" AM ~ 3 cs z d 4 I/2"k 6 9/4" MTL TUBE EIrGL45URE c (" MANUAL OP'I =RATED ROLLINb 6�R1L1.E %W. 3/4 MTL GHWVrEL. CdJRTAIN) COV'D. W/ SATIN STLS STL RE VEAL, PAINT TO MATCH Z BREAK MTL. VERTICAL JOINT FOR BREAK _ IMESTONE INDICATES CL: TER LINE METAL TO BE LOCATED BEHIND 6LAS6 END OF MANUAL OPERATED IF APPLICABLE. ROLLINS 6RILLE CURTAdN AS MFR. BY METRO p417R, Sim aSi■ &)Oh6q -%61 EXT. 256 INDICATES LINE OF O f n� V1 ATM BETH KRANTZ /-" RAISE DBPLAY PLATFORM CT T A , C4EU MTL. STUD (20 6A) FRAM INS kT 16 DEG.. SEC AM TO DOT. 7F BULKHEAD AOOME W TYPE "X" " BD .IMESTONE WAND W.L METAL. HAL IVE SHOW IN POW TRACK LW*nlWG 7N CEI LINS MTV TRACK 2) LA 1 y �•' "a TH rYPE "X" 6YP BD 12" MTL 'OHMS ABOVE NL.AZING 000CLS NT 24 (TYP) .IN�LSTONE 0 r A4 , 1146 SATIN STA%JW 6MM 04 A-1 MIN TOP OL.AZIN & "ROUS" SHIMS TO CONfT. 4" MIL. bIUPS IV M N. FAST06M. .AI' -O" AM LZ Lft • 7 1PETAIL 1 1/2" • I y 5/9" irfm "X" EXISTTN, GYP. BD, FINISH O D "I TYPE "X• GYP. BD PARTITION I ON I "• MTL STUD -- F�INb, PAINT 0 I OEAM CA AW AM) C STRAIN ,l� t�erAlN�e1e sTrtAl�) S/D" 61T. w GEII.ING REFER TO CEILINS DETAILS ON & SE -2 FOR SEISMIC BR,AGINS I I S " (20 6A� MIL. STUB FRAMN6 I I EXISTINS NUETRAL PER TO ORMA1N P1IOTEGT AS ItEi'S,l111ED MN BUS.D -OIJT TO MATCH EXIST M NUET RAL. PM COOK NTM L AOL4 IUD. EMT* STNIUGT. SAM 1•SQ MTTL 61.IWN6 C W#O.. SATIN ST. STL FINISH. 4 &16" MIN. FACE CLEARM" VV NEOPRDE SPACM AND GEAR M 1116' NOMINAL BITE MINI ' WW MIN WOE CLEARANCE PROVIDE SETTING BLOCKS NOT LE56 THIAN 4 ". CURB FACING - CUT FROM UMESTOW TILE U4 16" x 16" x I/2'TH SOLID BLOCKING SECURED TO SLAB M AU nk FLOOR *J/O ALL TFI4VAP` " SADDLE NUT c►�r► -F� u�ISTwr 12 6A V0tTIGAL HIRES 4'-O' O.C. BLACK IRON --t 1/8 METAL HAT C.HANEL BRAC►' I N6 DETAI AT 5TRUGTURAL BEAM5 FOR 5U5PENDED CoEILINC75 TYPICAL I OPEN .JOINT ! 4 " I I I 1 1/2 s 1-O (:7 r WORD GAP, WOOD Q RIS TO DETAIL A, DWb •ID-a. ' TYPE 'X' 6YP. BD, WC70V VENEER LIMESTONE FACING SET ON TNI .VJET 0 IIDMG�LTCS -- STOIQlNONT ++EAVM • V -2 1/p" APF I/2 C4EA t I 7°"P. 6LA6e F& c*Nf W„ MEOW c"'MR DRAWN CHECKED DATE 6/15/04 SCALE AS NOTED JO NO. 03113q SHEET OF S H F- 7IV T` g ar 1 /8•r .. p w N V N � � Z i Wh � q N � Q O in rJ M • �! J z � � o _ .. oc =N ~ � �z� V r � `N I "'• uno qf !! cc 0 3 VON = N 9L . O t � ~ Vn o 4 cc GINNIE z z W IE I~ W V H 0 as ca C c O r ~ 3 cs z d � O o Z M W c 0 W N� cc Z IL z Io O f n� V1 o" RE ' CT T A , C4EU ATF OF V A,& i::riGION DRAWN CHECKED DATE 6/15/04 SCALE AS NOTED JO NO. 03113q SHEET OF S H F- 7IV T` g ar 1 /8•r c7 0 cu 0 m N lD v G s r; 0 i rn rn 0 au r cn r.A. cn m r. Li 0 CL 7 O TYPICAL / I� Tom OEM GO sm rYP. AT I� 14sro vv iW/ I/4 q i q S Ib COLI" PIN& BY GAGIe SIdN GONTR 1� NEI 1 TYP. AT Ib o5 q O TYPICAL TYPICAL r.E ILI NIb I I Y TYPICAL _ • I -... r •:. •! - - .I - - -1 • -. .:.1- I • : - ': I - ' ` I - � I • r - ` f • - • • t •:. 1' • ' - -• I • I 1 - ' - ( '' • . I • �•-) .. • I • I : •_ I' - _. I I - � I .- I . -. I ••- r I� I I . -. I - I I`' .. •f 'I .• I -• I•. U. I F I. : I . I I I: I • I I I I l 1. r• I. .4 J. . I. • I I`' I _ I I 1 (- 1 . I 1 I•. I I • F I I 1. • A. - 1 _ I I I •. I I f I I I .. I I '. I 1 I• 1 -1 1 1 1_ 1 . 1' 1 I 1 :.•I: A. I' I I I• 1 I� f "I 1 I I I . ' I . • - • I � • • 1 ` 1 . .. I 1 I' I , - 1 I `I �I '1 . • • �. • I� I I � � 1 •I -•.• • I �' .. I I , - •'• I I I I 1 I. 1 k. M. ELEVATION 1/4• = 1'-0" ELEVATION 1/4' = I'-0" BRA FIXT. TYP. AT CEILIN& 4 NOTE ALL MIRROR PANELS TO HAVE POLIO E 6ES, TYPICAL. CLEAR MIRROR VV TOP t SOT. POE. O q LI wwx Gaaom J Kme. -------- TYP. AT S IZ b CEILINS low TO 5TOR 4&E q ELEVATION 1/4" = I' -0' b 1°IXop PL'r'Mc7D MINIX 004444 TOP FINISH IS \ SLITT JOINTS 1"04 FW4 q � ff Lff VAT I ON ELEVAT 1 ON 1/4" • I'-O" 1/4' • 1'-0' IO TYP. AT CEILINt6 I •I: =I. •'•i. 1 I• -h• .. 1 -'. � 1 1 ' •, Y , 1 , P. � •. I . I - ._I I J I _ I I_ I I. 1 1• i4 I' _ .1 1 : :1. I I I• I I .I I I.. •• i_ •• I 1 t 1 I L. _. '•1' ' 1 ..1• -- '`I` I 1 `I I I'' i• - 1 . '•I r :l . I M. 5 All q I I_ A, !! I ID-0 GEILINLG a w O OPEN TO _ka MALL AT 19+D I t I \\ I �� I 5 91 1 � N e \ TYP. �. Jo J O X V WALLS i W N • Z " � 1.. �_< 2 L W- � . E m . lab I N . i INDICATES - 'SFERMMN c Z O H O PAINT Z a W - NETUIIAI- \ ftA E SPREAD: 5, F 4OKE : O) 1 I I I I I I A :' I• I. PIER EEYONr[7 TILE TO BE INSTALLED IN A PATTERN AS INDICATED ON PLAN. V r=Ll!VATION Q 0 6ROUT SPEC: 1/16' WIDE MAXIMUM JOINT' 'MAPEI' KARAPDXY .1 61Aft 11 • 1'-0" STAIN -FIB EPDXY, 61ROUT C4L.00 : ALMOND. Tom• z - IL 4 O� a� FM*2 H OOK 1M' q I q .I I 1 ;p I' A..1 I .. I - � I 1 I �1 1 -I N4AS ED Mr/ VINEbAR i M ATER. ELEVATION I. .I tu 1/2' CLEAR 1/4' = 1' -0' I I I 1 I I) 1 I 1 1 t 12'x 12'x 1 /6" VINYL FLOOR TILE "ARM5TRONOO 5TANDARD EXCB.ON ® � 1/4 PIOE&W PLATE 6LA96 CLEAR MIRROR FLOOR M 6L.A55 PANELS I BASE 4' M1 H SASE " JOFISONITE" OC404 ALMOND. !.l_ VILSON ART' 00437 -160 MW tu ( CLASS I FLAME SPREAD RATINtS - FLAMMABILITY- MEETS OR EYZEED5 11 LAMINATE (M 9RMAD: 50 : 45) z DI SMAY PL ATFORM Ib ELEVATION 1/40 a ll-ON I Tom OEM GO sm rYP. AT I� 14sro vv iW/ I/4 q i q S Ib COLI" PIN& BY GAGIe SIdN GONTR 1� NEI 1 TYP. AT Ib o5 q O TYPICAL TYPICAL r.E ILI NIb I I Y TYPICAL _ • I -... r •:. •! - - .I - - -1 • -. .:.1- I • : - ': I - ' ` I - � I • r - ` f • - • • t •:. 1' • ' - -• I • I 1 - ' - ( '' • . I • �•-) .. • I • I : •_ I' - _. I I - � I .- I . -. I ••- r I� I I . -. I - I I`' .. •f 'I .• I -• I•. U. I F I. : I . I I I: I • I I I I l 1. r• I. .4 J. . I. • I I`' I _ I I 1 (- 1 . I 1 I•. I I • F I I 1. • A. - 1 _ I I I •. I I f I I I .. I I '. I 1 I• 1 -1 1 1 1_ 1 . 1' 1 I 1 :.•I: A. I' I I I• 1 I� f "I 1 I I I . ' I . • - • I � • • 1 ` 1 . .. I 1 I' I , - 1 I `I �I '1 . • • �. • I� I I � � 1 •I -•.• • I �' .. I I , - •'• I I I I 1 I. 1 k. M. ELEVATION 1/4• = 1'-0" ELEVATION 1/4' = I'-0" BRA FIXT. TYP. AT CEILIN& 4 NOTE ALL MIRROR PANELS TO HAVE POLIO E 6ES, TYPICAL. CLEAR MIRROR VV TOP t SOT. POE. O q LI wwx Gaaom J Kme. -------- TYP. AT S IZ b CEILINS low TO 5TOR 4&E q ELEVATION 1/4" = I' -0' b 1°IXop PL'r'Mc7D MINIX 004444 TOP FINISH IS \ SLITT JOINTS 1"04 FW4 q � ff Lff VAT I ON ELEVAT 1 ON 1/4" • I'-O" 1/4' • 1'-0' IO TYP. AT CEILINt6 I •I: =I. •'•i. 1 I• -h• .. 1 -'. � 1 1 ' •, Y , 1 , P. � •. I . I - ._I I J I _ I I_ I I. 1 1• i4 I' _ .1 1 : :1. I I I• I I .I I I.. •• i_ •• I 1 t 1 I L. _. '•1' ' 1 ..1• -- '`I` I 1 `I I I'' i• - 1 . '•I r :l . I M. 5 All q O b D�0 ID-0 GEILINLG a w O OPEN TO _ka MALL �c8 I t I \\ I �� I 5 91 1 � N e \ TYP. �. Jo J O X 1 L W N • Z " � �_< 2 L W- � . E m . lab I N . i amp co) - 'SFERMMN c Z O H O PAINT Z a W - I II'?-0 0 ftA E SPREAD: 5, F 4OKE : O) C49 A O FLOolt TILE). W X TILE TO BE INSTALLED IN A PATTERN AS INDICATED ON PLAN. V r=Ll!VATION Q 0 6ROUT SPEC: 1/16' WIDE MAXIMUM JOINT' 'MAPEI' KARAPDXY I (PL A041! SPREAD: 5, SMOKE : O) 11 • 1'-0" STAIN -FIB EPDXY, 61ROUT C4L.00 : ALMOND. #I z - IL 4 O� a� FM*2 H OOK 1M' q TRIP. MIR q Wr. MTV AT FINISH M AT0W MAPLE MM ! OR MUPLE VBM W86 III R.AME SPREAD RATING). 4W4 N4AS ED Mr/ VINEbAR i M ATER. ELEVATION 'TILE i GROUT SUPPLIED BY GAOL FOR THIN - SET INSTALLATION BY tu 1/4' = 1' -0' =AR TOP GOAT (GLASS G) - FLAME SPREAD: 16-200 C, C 0WRAC-TOR TO PROVIDE CACHE FM ONE GLY RT OF TOUGH UP FINI5F1. APPLIED 9/4" TH. FULL ME PLYtrMOOD PANEL ND VEFF..CiR FINISH SATIN 0001"E FINISH WALL U RAIL MTV. AT #5'- b "AFF. ON SITE *to. TO INSTALL ONE TYPE M "M AT THIS LOGATIOM - +V-0' ,MF EL EVAT 1 ON 1/4' • 1'-0" I I S 8 All ' G pawE J K-06. D�0 ID-0 LI a w O OPEN TO _ka MALL �c8 I t I \\ I �� I I I I 0 cq R Z 1 � N e \ � Jo J O X 1 K Z�� b _ .. W N • Z " � �_< 2 L W- BY ON-SITE 6.6. V Lba 0 2 0 m . $ & a INS %a t ftAME SPREAD: 5, SMOKE . O) TYr. amp co) 'SFERMMN c Z O H O PAINT Z a W - I II'?-0 0 ftA E SPREAD: 5, F 4OKE : O) C49 A O FLOolt TILE). W X TILE TO BE INSTALLED IN A PATTERN AS INDICATED ON PLAN. V r=Ll!VATION Q 0 6ROUT SPEC: 1/16' WIDE MAXIMUM JOINT' 'MAPEI' KARAPDXY I (PL A041! SPREAD: 5, SMOKE : O) 11 • 1'-0" STAIN -FIB EPDXY, 61ROUT C4L.00 : ALMOND. J ® AT END WALLS i I INDIGAT> =5 NETURAL ,• PIER, BEYOND TEMMIRED I � 1/2" CLEAR 6L A6% PANELS DISPLAY PLATrow TYP. AT CEILING �- OPEN S TO SALE5 AREA ELEVAT I ON 1/4" = I' -0" C42A R MMQROR Mr/ TOP t 190T. POE. O q 817X G pawE J K-06. 4 I I I I I LI -- MIIIRWR Vi" Jt71NfT'J► q ELEVAT 1 CAN 1/4" • 1 ,- • TYR. AT C911.1" REVISIONS BY ■ r m 1 L� 5 6 TYP. AT CEILIN & T T n B ig ,.1 TO i !'IrnWi RO" ELEVATION 1/4' = 1' -0" r 4 O INIPIGA'TE5 END OF FIXTURE IN ZSROUNP D At i 1 I t wood FINISH t t Ib I � ----+ I 1 JAL '.!6'1N MOLL IMIDYIv L 112!A A MY VC 00 VeNWt SUGM r"T ow m" Avm OWT IS caw mw ON VIA" F IXIUlC FA IA M4/ =Aft. mom gem ON ®TIER !TIDE. FASCIA ELMVAT1 ON "DURKAN C01.4"EIRGIAL' STYLE: LA &= 44 NO: LBE, COLOR: '702 DUNE S PAINT O 4 I I I I I \ \ a w O OPEN TO _ka MALL �c8 I t I \\ I �� I I I I 0 cq R Z � N e \ o �� Jo J O X MAW SPREAD: 5, SMOKE : O) K Z�� b _ .. W N • Z " � �_< 2 40 BY ON-SITE 6.6. V Lba 0 2 0 la a N $ & a INS %a t ftAME SPREAD: 5, SMOKE . O) _� �v amp co) 'SFERMMN c Z O (A5TM CA-026 - GOEFf ICIENT OF FRICTION: DRY N &XITE=O.'r4, O PAINT Z a W M.0olu ' NET NEOLJTE =OA6, MEETS OR EXCEEDS ADA SLIP C XFFICIENT5 FOR 0 ftA E SPREAD: 5, F 4OKE : O) C49 A O FLOolt TILE). W z TILE TO BE INSTALLED IN A PATTERN AS INDICATED ON PLAN. V '„ R M Y4WAM5" 0-4+" AHM IRA0154 E6 -SFQ. E=NAMEL PAINT Q 0 6ROUT SPEC: 1/16' WIDE MAXIMUM JOINT' 'MAPEI' KARAPDXY O t (PL A041! SPREAD: 5, SMOKE : O) O STAIN -FIB EPDXY, 61ROUT C4L.00 : ALMOND. z - IL 4 O� a� INSTALL FLOOR TILE PER MF6. INSTALLATION INSTRLJCTIONLS. 0 SPECIAL FINISH STAIN MV SEM11- 6LOSIS aZM LACdM ON GMMRTER, SAM SLIP W C474'LZTEP FLOOR TILE INSTALLATION TO BE VACUJMED 4 LIGHTLY FINISH M AT0W MAPLE MM ! OR MUPLE VBM W86 III R.AME SPREAD RATING). N4AS ED Mr/ VINEbAR i M ATER. 3/4' 1GQRW&ON" GLV4tTER SAM SLIP MATGIED MAPLE VI NEPR PARTKLE aOARV 'TILE i GROUT SUPPLIED BY GAOL FOR THIN - SET INSTALLATION BY tu O"TE 6.0. TILE 4 GROUT AVAILAOLE FROM: "IMOLA ", KAMI, FLORIDA =AR TOP GOAT (GLASS G) - FLAME SPREAD: 16-200 C, C 0WRAC-TOR TO PROVIDE CACHE FM ONE GLY RT OF TOUGH UP FINI5F1. ('305r319 -4034 EXT. 112, ATTN. 51MIONl TEAME. t 12'x 12'x 1 /6" VINYL FLOOR TILE "ARM5TRONOO 5TANDARD EXCB.ON ® � 1/4 PIOE&W PLATE 6LA96 CLEAR MIRROR FLOOR M COLOR 051804 DESERT N*E. AE BASE 4' M1 H SASE " JOFISONITE" OC404 ALMOND. !.l_ VILSON ART' 00437 -160 MW tu ( CLASS I FLAME SPREAD RATINtS - FLAMMABILITY- MEETS OR EYZEED5 11 LAMINATE (M 9RMAD: 50 : 45) z moo 'MN1YL FLOOR i BASE SUPPL.I® +1 INSTALLED BY ON SITE 6►.G. D METAL D SATIN STAINL,E55 STEEL 04 METAL FINISH slA TE OAF Ohl► At i 1 I t wood FINISH t t Ib I � ----+ I 1 JAL '.!6'1N MOLL IMIDYIv L 112!A A MY VC 00 VeNWt SUGM r"T ow m" Avm OWT IS caw mw ON VIA" F IXIUlC FA IA M4/ =Aft. mom gem ON ®TIER !TIDE. FASCIA ELMVAT1 ON INDICATES ENP OF FIXTURE IN FOREGROUND RAISED DISPLAY IlAISW DISPLAY MATT+Ow PLATFORM 4 1 /4•x 6 5/4' MTL T1JBE ENCI.OSURE Aj""I"GO R ELEVAT (rOR MANUAL OPERATED ROLLING I NSTALLATION VETAI L 1/4' = 1' -0" GRILLE CMTAINII COVD. W/ SATIN STLS A 5TL EpEMc MTL. I R lo NED FANC'E ODE �OMp�I C PROVED Ap 0f 4 0 'Cukw� crl p, 5 � FINISH SCHEDULE 1 l © CARPET "DURKAN C01.4"EIRGIAL' STYLE: LA &= 44 NO: LBE, COLOR: '702 DUNE S PAINT O SIN MML.UTAMS" 0511 -1959 GASA8A ME ENAMEi. PAINT. I I I I I \ \ M15-61mi OPEN TO _ka MALL (C4 A�6 1 FLAME SPREAD RATIN& - FLAMMABILITY: MEETS OR EXCZWS I t I \\ I �� I I I I 4 REGXAREMENT5 FOR NFPA CLASS 1, SMOKE DENSITY: ASTM E662 -430 PAINT "SFIERM M'MLLIAmo SSM4-1938 CA AaA MELON SATIN ENAMEL PAINT. \ I I I (SATIN) MAW SPREAD: 5, SMOKE : O) 4 CARPET 5UPP1_IED BY GACI`E FOR DIRECT 6L.tE DOPIN INSTALLATION INDICATES ENP OF FIXTURE IN FOREGROUND RAISED DISPLAY IlAISW DISPLAY MATT+Ow PLATFORM 4 1 /4•x 6 5/4' MTL T1JBE ENCI.OSURE Aj""I"GO R ELEVAT (rOR MANUAL OPERATED ROLLING I NSTALLATION VETAI L 1/4' = 1' -0" GRILLE CMTAINII COVD. W/ SATIN STLS A 5TL EpEMc MTL. I R lo NED FANC'E ODE �OMp�I C PROVED Ap 0f 4 0 'Cukw� crl p, 5 � FINISH SCHEDULE 1 l © CARPET "DURKAN C01.4"EIRGIAL' STYLE: LA &= 44 NO: LBE, COLOR: '702 DUNE S PAINT O SIN MML.UTAMS" 0511 -1959 GASA8A ME ENAMEi. PAINT. OILY) YMPTH: 12, TUFTED / ULTRA ORMANCE DUPONT NYLON CARPET. M15-61mi (PLAME SPREAD: 5, SMOKE : O) (C4 A�6 1 FLAME SPREAD RATIN& - FLAMMABILITY: MEETS OR EXCZWS REGXAREMENT5 FOR NFPA CLASS 1, SMOKE DENSITY: ASTM E662 -430 PAINT "SFIERM M'MLLIAmo SSM4-1938 CA AaA MELON SATIN ENAMEL PAINT. OR LESS). (SATIN) MAW SPREAD: 5, SMOKE : O) 4 CARPET 5UPP1_IED BY GACI`E FOR DIRECT 6L.tE DOPIN INSTALLATION BY ON-SITE 6.6. b PAINT "SHERMN ML.LIAM5" X1949 MWITE RADtW FLAT LATEX PAINT (PLAT) ftAME SPREAD: 5, SMOKE . O) N I6'xl6'x5/Ib" RECTIFIED PORC45.AIN CERAMIC TILE, COLOR: LIME 30A. 'SFERMMN GEIRAW (A5TM CA-026 - GOEFf ICIENT OF FRICTION: DRY N &XITE=O.'r4, O PAINT MLLIAM5" OSV+ -" V#M RADW 504 -aow EK*tL PAINT M.0olu ' NET NEOLJTE =OA6, MEETS OR EXCEEDS ADA SLIP C XFFICIENT5 FOR (5EMI -6LO%) ftA E SPREAD: 5, F 4OKE : O) C49 A O FLOolt TILE). TILE TO BE INSTALLED IN A PATTERN AS INDICATED ON PLAN. PAINT ® '„ R M Y4WAM5" 0-4+" AHM IRA0154 E6 -SFQ. E=NAMEL PAINT 6ROUT SPEC: 1/16' WIDE MAXIMUM JOINT' 'MAPEI' KARAPDXY M&-%W (PL A041! SPREAD: 5, SMOKE : O) STAIN -FIB EPDXY, 61ROUT C4L.00 : ALMOND. INSTALL FLOOR TILE PER MF6. INSTALLATION INSTRLJCTIONLS. , HOOD SPECIAL FINISH STAIN MV SEM11- 6LOSIS aZM LACdM ON GMMRTER, SAM SLIP C474'LZTEP FLOOR TILE INSTALLATION TO BE VACUJMED 4 LIGHTLY FINISH M AT0W MAPLE MM ! OR MUPLE VBM W86 III R.AME SPREAD RATING). N4AS ED Mr/ VINEbAR i M ATER. 3/4' 1GQRW&ON" GLV4tTER SAM SLIP MATGIED MAPLE VI NEPR PARTKLE aOARV 'TILE i GROUT SUPPLIED BY GAOL FOR THIN - SET INSTALLATION BY - M.4ME SPREAD: Ib-IM, SMOKE DEVELOPED- 163, O"TE 6.0. TILE 4 GROUT AVAILAOLE FROM: "IMOLA ", KAMI, FLORIDA =AR TOP GOAT (GLASS G) - FLAME SPREAD: 16-200 C, C 0WRAC-TOR TO PROVIDE CACHE FM ONE GLY RT OF TOUGH UP FINI5F1. ('305r319 -4034 EXT. 112, ATTN. 51MIONl TEAME. 12'x 12'x 1 /6" VINYL FLOOR TILE "ARM5TRONOO 5TANDARD EXCB.ON ® � 1/4 PIOE&W PLATE 6LA96 CLEAR MIRROR FLOOR M COLOR 051804 DESERT N*E. BASE 4' M1 H SASE " JOFISONITE" OC404 ALMOND. PEASTIG VILSON ART' 00437 -160 MW ( CLASS I FLAME SPREAD RATINtS - FLAMMABILITY- MEETS OR EYZEED5 11 LAMINATE (M 9RMAD: 50 : 45) REGIJIREMENT5 FOR NFPA CLAW I, SMOKE V601 Y: LE56 THAN 450) 'MN1YL FLOOR i BASE SUPPL.I® +1 INSTALLED BY ON SITE 6►.G. D METAL D SATIN STAINL,E55 STEEL 04 METAL FINISH FM5H 16'x W" x NIb" ORfMA PI RL.A MONED L.IM15TONE TX.E �4 L.IsTONE T ILE 'TILE 90"" 8Y C.ACrFE�, INSTALLED 13Y O11 -�51TE 6.6. GEILINb TILE * •ARMSTRONMS' MIN AWARD /FIRE 6UARD FMM nl!M #M 245c 46N 7/0 (5T011l9�ONT) TILE AVAL AW PftM: 'GLSTOM GRAFT MAPW 1 STONE, MG.' MAMA, FLORDA STORAGE RM. MNITE LAY-IN PANMS (FIRE RA= UL LAM I FRJ INSTALLED FV 9 A25, AT1lh DAM SG!#A.TE (FIRE RAT®) APPROVCD FIRE RA'TeD INCITE E ICE GRID 9USN'B ION SYSTEM. NOTE INS TALL ALL TILE GAIT TO SIB Ab'S MIN ON S TOtREI'RONT ELJNAT10N5 FLAW ��: B' SMOKE 5 INSTALL ALL TILE MATH V*w Ml M AK d4R01Jf JOINTS. ALL OUTSOE C49" JJ�� PLAbTIG "M L.M�ANIATE FOR FITTING ROif)M 19514GM TOP. GONDITIONI3 TO SRI' .pG!°D' MV MOVED FIMMlED E EDGES. LAMINATE "NEVAMVIIt' WhGOOIT CAMOUFLAGE GMIAdMN TEX'f1A!!D. LICITLY IV& UM15TOW WTALLAT1014 FM VMWAR Nil' MAIM ftTr!�Etcew 6ROVf: '.MM10' SAN= AR GROUT, DOLOR: ANTM MIT 1- 0004161 Mr00D VENEER SJ"•IM Ilf CACHE. 9b" MMDTN STOCK INSTALL.® BY 044M 64. SE&M %MY AND INSTALL PM 10P6'JPI50 A CLEAR METRATMb NAM IN COM PL.IANGE M'M'TH MANAIFAGTIAREICS ATIONb. �UN MAU" 00" 15 60L.D) Ab W* eY "AQJA MAX MG." ft2) 446.6NT1 "m 2 � 1 "M LAMIW4TE FOR T It FAGMb. a u LAMINATE '9"ML' M ART" SIM-60 P"TE q�y C E (&(PPM BY CAOINECT1111Y GONITRAGTM ti rt, • A DRAWN CHECKED AT Ci l S' ' SCALE AS NOTED JOB NO. 03113q SHEET OF SHEETS v 0 0 clu LO LO m c a, f-- v+ a to 0 M rn m rn O ti tn LA- r c'n cn O U O r p PACE or M"ISI WALL OR COLUMN REFER TO ID-S n 4 _.i Q x 5TA66 7M DOUBLE TUBE FLUORESCENT LIGHT FIXT. 5►�GTIDN L16W FIXT. r WHITE MELAMINE .J Q x ai SECTION 5/ 4" • I'-GM' wZ EI�. Rooms APPLIED PREFINISIE,D m OASE 9 60 SH x YV PAINT FIN 147M CAN PAW AT 4 Type 'X' bY1p. W. .._. —._ vv PAINT rINISN O 14"90. CONT. REVEAL FAINT FLAT MACK, TY'P. it INDICATES VALENCE ABOVE, DOT. AT +8' -O"APF WOOD GAP —� MCOD PINISH O 4'-4 9/4" CLEAR OR NpNb R!'RR TO Ip-0 FOR ADDITIONAL X � DIFl1�101� 5 �► A PETA I L PREIIINISFEO BLACK r +10' - 0 " AFF 5/6 6YP. BD FIN. PAINT 5/4' MD.P. PANEL W/ ND YENImt Ib INDICATES FRONT FAGS OF VERTICAL ENDOAP AT OMDER �r METAL. " TYPE 'X' GYP. BO. W/ PAINT FINISH mining r',rr �N 216" METAL STUD r (20 6A0 FRAMING n " HOLLOW CORE M APPLIED PREFIN ISFED DOOR (rrPE 1 OR « WD BASE - x 5"H. VOW FINISH qO W/ WOOD FINISH q D T I L. WOOD CASINO WGOD FINISH HALF SCALE f16 METAL STUD . (20 6A) FRAMING %" TYPE '.X' GYP. BD. W/ PAINT FINISH is1 5/6" GYP. BD FIN. PAINT V40017 GAP WOOD FINISH DETA I L 9 = 1' -0" L S�GTI ON W/ WD VEER Ib oo R0VVABLE V2 CLS.L. E SILVER PARR IOL.IG E66CXA M 1.1r SECTION 5J4" • 1'-0" 4 1 /4 CLEAR &LAW 10� MIRROR ON 1/®' MASTIC %IPPL W ! INSTALLM BY 64. PAINT BLACK DETAIL n PAINT BLACK REVISIONS By li I7ETA I L BOT. AT +0' -0 r ---- `O. REVEAL (q Q 'X' 0" R6" TYPE GYP. W. �'► Y4/ Y'O VL=NR Ib 5r FAGS OF GYP. M AVAPT � APPL PW INISHM M SASE 14rTH. x S'H. 216" METAL 6=0 - A - STIR Y4/ PAINT FINISH 0 �y''► I 5/b' TYP'E 'X' GYP. OP. (20 6A) FRAMING �I250 TYPE "A" _ ac •c $ x _� i (2) IN5TA WX5 68.4* W/ PAINT FINISH O V ON BRACKETS & JPPL.IED STANDARDS. (2) INSTANCES 21.1• 2 1/2" MTL SY ON SITE 64. d = A damb VON FINISH AT STANDARD �o STUD FiRAMINiS �. %" TYPE 'X' GYP. IV. FLAT TAPE i SPACKLE APPLIED PREfIN1Sl•ED W/ PAINT FINISH O ` OVER FAGS OF STANDARD Q Wp BASE 3b"TH. x 5"14. PV � - GLEAN OUT STANDARD 0 APPLIED PREFINISFED GROOVE i PAINT TO PAINT FINISH MITER GUT WD BASE �"TH. x S"H. W/ MATCH WALL. PAINT FINISH MITER CUT �/b" ME'T'AL b'TUD FAGS AT FRONT TYPICAL 2 91 (20 6A) F1lAMINIIS► TY w-lo L 2-% n 4 _.i Q x 5TA66 7M DOUBLE TUBE FLUORESCENT LIGHT FIXT. 5►�GTIDN L16W FIXT. r WHITE MELAMINE .J Q x ai SECTION 5/ 4" • I'-GM' wZ EI�. Rooms APPLIED PREFINISIE,D m OASE 9 60 SH x YV PAINT FIN 147M CAN PAW AT 4 Type 'X' bY1p. W. .._. —._ vv PAINT rINISN O 14"90. CONT. REVEAL FAINT FLAT MACK, TY'P. it INDICATES VALENCE ABOVE, DOT. AT +8' -O"APF WOOD GAP —� MCOD PINISH O 4'-4 9/4" CLEAR OR NpNb R!'RR TO Ip-0 FOR ADDITIONAL X � DIFl1�101� 5 �► A PETA I L PREIIINISFEO BLACK r +10' - 0 " AFF 5/6 6YP. BD FIN. PAINT 5/4' MD.P. PANEL W/ ND YENImt Ib INDICATES FRONT FAGS OF VERTICAL ENDOAP AT OMDER �r METAL. " TYPE 'X' GYP. BO. W/ PAINT FINISH mining r',rr �N 216" METAL STUD r (20 6A0 FRAMING n " HOLLOW CORE M APPLIED PREFIN ISFED DOOR (rrPE 1 OR « WD BASE - x 5"H. VOW FINISH qO W/ WOOD FINISH q D T I L. WOOD CASINO WGOD FINISH HALF SCALE f16 METAL STUD . (20 6A) FRAMING %" TYPE '.X' GYP. BD. W/ PAINT FINISH is1 5/6" GYP. BD FIN. PAINT V40017 GAP WOOD FINISH DETA I L 9 = 1' -0" L S�GTI ON W/ WD VEER Ib oo R0VVABLE V2 CLS.L. E SILVER PARR IOL.IG E66CXA M 1.1r SECTION 5J4" • 1'-0" 4 1 /4 CLEAR &LAW 10� MIRROR ON 1/®' MASTIC %IPPL W ! INSTALLM BY 64. PAINT BLACK DETAIL n PAINT BLACK REVISIONS By li I7ETA I L BOT. AT +0' -0 r ---- `O. REVEAL (q Q 'X' R6" TYPE GYP. W. �'► Y4/ Y'O VL=NR Ib �" TYPE 'X' *YP. BG. FAGS OF GYP. +r1« r � APPL PW INISHM M SASE 14rTH. x S'H. TYPE 'X' GYP. W. W/ Y4000 FINISH O Y4/ PAINT FINISH 0 �y''► I 5/b' TYP'E 'X' GYP. OP. GA51N6 FI _ ac •c $ x _� i (2) IN5TA WX5 68.4* W/ PAINT FINISH O V ON BRACKETS & JPPL.IED I (2) INSTANCES 21.1• 2 1/2" MTL SY ON SITE 64. d = A damb VON T �o STUD FiRAMINiS �. c r APPLIED PREfIN1Sl•ED Z Wp BASE 3b"TH. x 5"14. PV p 0 PAINT FINISH MITER GUT 0 • FACE AT FRONT �a TY w-lo L 2-% n I D E TA I L –M INDICATES VALENCE ABOVE, BOT. AT W -O"AFF � Q r40M GAP WOOD FINISH � NINE HTECT 11 -101r " 1 �" p STATE Of *sHhGT04 PLYWD CABINET W/ Y400D VENEER, TO d ' 13466, I WIN METAL STUD FINISH ® FOR HINSE DOOR LOCATIONS AND (20 6A) FRAMINS INDICATES SWIMS C.I..OgET HAN6�Ra<7D ! ". TYPE 'X' 6YP. W. �- OF HIN6EV DOOR SHELVING LOGATION5 W/ PAINT FINISH 0 (ONE INSTANCE) m 7 5/4" PARTICLE 10 APPLIED I'M INI.,IEO 4 I.c r T ` -- I A MH ID MINE FINISH WD BASE %NTH. x 1 % W/ PA INT FINISH N � REVEAL, PAINT � r >� HTER CUT FACE T 4 T FLAT 15L.AC,K V4000 GAP � WOOD GAP MOOD FIN15H ® -� WOOD FINISH err DETA I LI Si" lr �' " 1r « IND�E BM. - AT •++9' -0'AFF INDICATES SHUN& OF HINGED DOM (ONE INSTANCE) 4 _.i Q x 5TA66 7M DOUBLE TUBE FLUORESCENT LIGHT FIXT. 5►�GTIDN L16W FIXT. r WHITE MELAMINE .J Q x ai SECTION 5/ 4" • I'-GM' wZ EI�. Rooms APPLIED PREFINISIE,D m OASE 9 60 SH x YV PAINT FIN 147M CAN PAW AT 4 Type 'X' bY1p. W. .._. —._ vv PAINT rINISN O 14"90. CONT. REVEAL FAINT FLAT MACK, TY'P. it INDICATES VALENCE ABOVE, DOT. AT +8' -O"APF WOOD GAP —� MCOD PINISH O 4'-4 9/4" CLEAR OR NpNb R!'RR TO Ip-0 FOR ADDITIONAL X � DIFl1�101� 5 �► A PETA I L PREIIINISFEO BLACK r +10' - 0 " AFF 5/6 6YP. BD FIN. PAINT 5/4' MD.P. PANEL W/ ND YENImt Ib INDICATES FRONT FAGS OF VERTICAL ENDOAP AT OMDER �r METAL. " TYPE 'X' GYP. BO. W/ PAINT FINISH mining r',rr �N 216" METAL STUD r (20 6A0 FRAMING n " HOLLOW CORE M APPLIED PREFIN ISFED DOOR (rrPE 1 OR « WD BASE - x 5"H. VOW FINISH qO W/ WOOD FINISH q D T I L. WOOD CASINO WGOD FINISH HALF SCALE f16 METAL STUD . (20 6A) FRAMING %" TYPE '.X' GYP. BD. W/ PAINT FINISH is1 5/6" GYP. BD FIN. PAINT V40017 GAP WOOD FINISH DETA I L 9 = 1' -0" L S�GTI ON W/ WD VEER Ib oo R0VVABLE V2 CLS.L. E SILVER PARR IOL.IG E66CXA M 1.1r SECTION 5J4" • 1'-0" 4 1 /4 CLEAR &LAW 10� MIRROR ON 1/®' MASTIC %IPPL W ! INSTALLM BY 64. PAINT BLACK DETAIL n PAINT BLACK REVISIONS By li SECTION 5 wu.F SCALE " I /4"TH CLEAR O 6L.AW MIRROR GK+1 I M" MIASTIG BY 6.G REVIEW ED FOR CODE COMPLIANCE fib" TYPE 'X' GYP. BID. YV PAINT FINISH ® jUL 13 2004 216 METAL STUD (20 &A) FRAMINb Ci DING t Of Tuk�►ila ON " BUIL NISI cr TYPE 'X' 6Y'P. W. W/ PAINT FINISH 0 215" METAL STUD (20 &A) M AM N S r r r rrr rrr O F REI INISHED A BLA�GK it L 5/6 6Y"P. w -► FIN. PAINT WOOD VEtEFR PANEL. FINISH DETAIL � APPLIED PRM INISHM WDOD GAP ND BASE 3b"TH. x 5"H. V4000 FINISH O W/ Y*= FINISH 0 _ 5/8" 6YP. BD GL.b FIN. PAINT ► "x�i' WD Mu* I4000 FINISH qU 4 RECF.�ED IFLLJORE5CLNIT LIGHT COVE wnr'..►YI...F•.+.s ..w► .w_« .. BORDER W/ 1/2" r ---- `O. REVEAL (q Q 'X' R6" TYPE GYP. W. �'► Y4/ Y'O VL=NR Ib �" TYPE 'X' *YP. BG. FAGS OF GYP. NV PAINT FINIV O � APPL PW INISHM M SASE 14rTH. x S'H. TYPE 'X' GYP. W. W/ Y4000 FINISH O Y4/ PAINT FINISH 0 APPLIED PARTICLE O TA I L � s+�"'DO GA51N6 FI _ ac •c $ x _� i HALF WALE (3) ADJ. 6LAS6 SHELVES SECTION 5 wu.F SCALE " I /4"TH CLEAR O 6L.AW MIRROR GK+1 I M" MIASTIG BY 6.G REVIEW ED FOR CODE COMPLIANCE fib" TYPE 'X' GYP. BID. YV PAINT FINISH ® jUL 13 2004 216 METAL STUD (20 &A) FRAMINb Ci DING t Of Tuk�►ila ON " BUIL NISI cr TYPE 'X' 6Y'P. W. W/ PAINT FINISH 0 215" METAL STUD (20 &A) M AM N S r r r rrr rrr O F REI INISHED A BLA�GK it L 5/6 6Y"P. w -► FIN. PAINT WOOD VEtEFR PANEL. FINISH DETAIL � APPLIED PRM INISHM WDOD GAP ND BASE 3b"TH. x 5"H. V4000 FINISH O W/ Y*= FINISH 0 _ 5/8" 6YP. BD GL.b FIN. PAINT ► "x�i' WD Mu* I4000 FINISH qU 4 RECF.�ED IFLLJORE5CLNIT LIGHT COVE wnr'..►YI...F•.+.s ..w► .w_« .. BORDER W/ 1/2" r ---- `O. REVEAL (q Q 'X' R6" TYPE GYP. W. PAINT WHITE Y4/ Y'O VL=NR Ib 'SUPPLED i INSTAL.I.ED BY 6.0. FAGS OF GYP. � DD PARTITION I" TYPE 'X' GYP. W. ' Y4/ PAINT FINISH 0 I Y4000 FINISH 0 H N o .., GA51N6 _ ac •c $ x _� i .. (3) ADJ. 6LAS6 SHELVES V ON BRACKETS & JPPL.IED I BY CAGY, INSTAL= ` I SY ON SITE 64. d = A damb VON T �o 1 BASE UNIT + Y4/ (2) DRAWERS ! • I LrLOCC.KS SUPPLI Y DY GAMNETRY CONTR. INSTALLED By ON SITE oz. L LT SECTION 95/4 • I'-O" a SECTION 1� r A� DOUBLE TUBE FLUOR LIGHT STRIP r PAINT INTERIOR Y4HITE WD VENEER PANEL. FINISH U9 STYLMARK MI kXY34 A 6LE 1 /4 CLEAR &LAW O MIRROR ON MIA SM W/ TOP i BUT. POL. CAIROME "J" MLD65 SUPPLIED My INSTALLED BY ON SITE 64. PC-TAIL 3" = 1' -0" AuR Minim w om Y4ITHOUT J M UO. TO PIT TIONT At MAX. 1/16" K OPEN JOINTS - CrA" ALL JOINT'S N CLEAR SI LIC, M. ALL PAhlLA DIVIDERS, MLOOD PILLEIRS, ETC. NOTED AS SUPPLIED ! PRIMED BY 0A8INETRY GONTIRAC.TOR TO OE FIELD FINI'SHM BY OWE 04. IA I �. MTE ME1.AN�1 4 J x O lb 4 PAGE OF *YP. 00 "&, PAINT FA" OF GYP. ;l : OD • ARTITION .x SATIN CHROME WALL U RAIL .:� WD. AT +S'- b"APF. GWKIED BY CACHE, TO ! " INST. Nv ` �' PREDRILI.ED HOLES AM PAST! Oft 'SUPPLIED B'Y GAB. CONTR J\ c ? APP'LIW #t"TH PAIlTICA.E BD PANEL. W/ row v040% FINISH O APPLIED PREFINIS ED M DAM %"TH. x 5"14. W/ WOOD FINISH qO SE wTIDN I• Ri" TYPE 'X' GYP. W. W/ PAINT FINISH I�r APPLIED PREFINISHED ry BASE Ik"TH, x 5 Y4/ PAINT FINISH MITER GUT FAGS AT FRONT 4 TYPICAL 2,..SI,DES " Q 14" SO. CONTIN UO1.0 � Cl REVEAL, PAINT REVEAL FLAT BLACK i�► INDCTATES VALENCE ABOVE," BOT. AT +6' -O "AFF WOOD CAP FINISH Y4= 3/8" PLYWOOD ,//�� BAGKINS PANEL. I BY GAB. UMM PE A Y4D VEN�R Ib FAGS OF GYP. BD CON5TRUGTION R M 1 /4"TH CL.R 6LA55 ,I O MASTIC BY 6.6. O r - r APPLIED PREFIWISHW r0 BASE % x s•M- ry Fl OD FINNSM O SECTION b In UN 21 20 ? wnr'..►YI...F•.+.s ..w► .w_« .. rAC,E of OYP. OD GLi, PAINT © . 51 8AN Yp MLOO V40M FINISH O F V4"TH CLEAR 6LASS MIRROR ON 1/S MAbTIG 'SUPPLED i INSTAL.I.ED BY 6.0. FAGS OF GYP. � DD PARTITION im APPLIED PREFINISHED YV BASE 46 x 5 — At MOOD FINISH q IA I �. MTE ME1.AN�1 4 J x O lb 4 PAGE OF *YP. 00 "&, PAINT FA" OF GYP. ;l : OD • ARTITION .x SATIN CHROME WALL U RAIL .:� WD. AT +S'- b"APF. GWKIED BY CACHE, TO ! " INST. Nv ` �' PREDRILI.ED HOLES AM PAST! Oft 'SUPPLIED B'Y GAB. CONTR J\ c ? APP'LIW #t"TH PAIlTICA.E BD PANEL. W/ row v040% FINISH O APPLIED PREFINIS ED M DAM %"TH. x 5"14. W/ WOOD FINISH qO SE wTIDN I• Ri" TYPE 'X' GYP. W. W/ PAINT FINISH I�r APPLIED PREFINISHED ry BASE Ik"TH, x 5 Y4/ PAINT FINISH MITER GUT FAGS AT FRONT 4 TYPICAL 2,..SI,DES " Q 14" SO. CONTIN UO1.0 � Cl REVEAL, PAINT REVEAL FLAT BLACK i�► INDCTATES VALENCE ABOVE," BOT. AT +6' -O "AFF WOOD CAP FINISH Y4= 3/8" PLYWOOD ,//�� BAGKINS PANEL. I BY GAB. UMM PE A Y4D VEN�R Ib FAGS OF GYP. BD CON5TRUGTION R M 1 /4"TH CL.R 6LA55 ,I O MASTIC BY 6.6. O r - r APPLIED PREFIWISHW r0 BASE % x s•M- ry Fl OD FINNSM O SECTION b In UN 21 20 ? DRAWN CHECKED SC LE A5 NOTED JOB NO. 031139 SHEET I OF SHEE .. _..+w, .. •.�.wwArw. —..w.. ...► ......,.. -�.• �.�RY'..�F. wn� � ..rrfl..M. wnr'..►YI...F•.+.s ..w► .w_« .. IA w � N A 8 � qw n N W F.. N — R► x J H N o .., x LU N • 1. _ ac •c $ x _� i .. V � N W OC + N d = A damb VON �o "Emp �. c r it 0 Z W 0 0 z � Q NINE HTECT DELIS T WT Na STATE Of *sHhGT04 DRAWN CHECKED SC LE A5 NOTED JOB NO. 031139 SHEET I OF SHEE .. _..+w, .. •.�.wwArw. —..w.. ...► ......,.. -�.• �.�RY'..�F. wn� � ..rrfl..M. wnr'..►YI...F•.+.s ..w► .w_« .. N` a 0 m 0 un c CL) 1- vti 3 t� a w r - N rn m 0 7W , NEW ROOFTOP A. C. UNIT, FEEDER TO BE 3 - #4, 1 -#8 COPPER, 1' CONDUIT. DISC. TO BE 60A /3P, NEMA 3R WITH 50 AMPS FUSES. VERIFY DETAILS OF THE ACTUAL UNIT INSTALLED AND PROVIDE ELECTRICAL AS PER THE INSTALLATION INSTRUCTIONS. PUSH BUTTON W/ LOW VOLTA6E WIRIW RUN TO BUZZER AT GASH V~ IN 1/2" C42"IT A20 A33, 35, 37 e"TIft PAjqLs A32 47m4o BOARD POWER S SIGNAL PLAN PATCH GABLE RJ-12 GAT 3 CCALE A26 �- A28 � APP A30 GAO. LINES DSL RouTER CENTRAL. PATCHIN& STATION "D2" SHTGH / NO PATCH GABLE RJ-45 GAT 5E GABLE PC/RE ASTERS TO R.1-AS JACK / WALLPLATE PC MODEM TO RJ-12 JACXAXALLPLATE INUN IN 3/4" MTL CONDUIT) CADV'RAL PATCH LABEL D TEL* D5L D D TEL. D DIms < D� V09 D vOg D D V02 D�o2 D D va O DOI s " C yM rATGHIN6 PAIRS LIST; 12 POItT BOX PM 4K*4 -1211 (6) VOK.E 4*" PM 41 k*- t 6 (6) DATAAM JACK IPM Ab M * BY %VVITOW. CENTRAL PATCH I NG BOX 11 11 TO M MT&= AT *40 OVA! om M STORAiE ROOM NOT TO '.SGA!.v TAT MV PLEXI LOCK BO FiTil MTV. AT + AFF A22 TO CZNTRtAI. PATCHING STATION IN STORA 15 ROOM TO EACH PG RE61ST13 GAT 5E FOR DATA GAT 3 FOR VOICE (MODEM OR PHONIES i I � I I -- A 16 H INDICATES 6" ( +8 1 I RED AIS DISPLAY I P+oI.E 20 AMP. NON MI�W PLATFORM � � FUSED DISCON ECT BOTH SIDES ABOVE ENTRY SOFFIT SWITCH FOR SION MTV RUN EL.EG., PHONE, +! DATA WIRINib A2 I fl IN GASH V~ THRU SAL AItE�► TO END OF UNIT FOR FUTURE USE. rust - I GHAHEL LETTER ON U TIME CLOCK GIROUIT A4 I I U SEPARATE CIRCUIT III �' BUZZ�t MT'D. IICV. OUTLET FOR r r - V "XPr*M SEC KITY ON SIDE PANEL r` - T GON'TR�fUl. BOX - MTD OF FIXTURE I +8 I! ' ABOVE ENTRY SOFFIT GAt A10 Al2 A18 I � A24 FT 2'-0" A8 A14 NOTE: ALL GABLES FROM mod:. M FMOISTER MILL BE HOMO IN BACK TO THE CENTRAL PATCHING STATION LOCATED IN STORASE ROOM. RUN IN 3/4" EMPTY METAL CONDUIT VV PULL KRE FOR FUTIM RESISTERS. VERIFY VV GACFE (WANITITY OF INITIAL RIEWSTERS FOR OPENIN16r. ALL DATA CABLES MILL BE TERMINATED TO EIA/TIA sblA"!B SPECIFICATIONS. ALL VOICE C/1>L'LES HILL 19E TERMINATED TO U50G SPECIFICATIONS U5121tANQ PARTS LIST: 4 PORT Box P/N 4M4 -41P (I) VO" 4 PM 41106 -1tLb (2) DATA JACKS IPM 0 MP& BY %"TOW. 4 PORT JACK 11171 '' TO W WED AT FjWw" NtEi1SM NOT TO SGAL.E ELECTRI 5CHEMATIC SECTIONS o- REC9 56ED MOUNTED OUTLETS INSTALLED BACK CK WALL AS A T 4 SHOW FIELD VERIFY EXACT LOCATION. CABINETRY GONTR. TO PROVIDE GUT OUT BACK PANEL IN +q" t71 ib INALL CASE FOR OUTLETS, PROVIDE ACCESS THRI! GASH L MAP UNIT 4 SHOY''IGASES FOR SHOWCASE L16HT I TERMINAL INSTALLATION, HOOK UP ! INTERCC ECTION REGE55ED MTV OUTLETS INSTALLED IN FACE OF DEMISING WALL OF TONER CABINET FOR MUSIC SYSTEM. CABINETRY CONTRACTOR TO PROVIDE 12"14 x 18"W GUT -= PAft FOR AC41 '.�i, EIRED IN WIDTH OF . -- UNIT AT +600AFF. CE R �ZG pN1P �,,p,N 1 � 204 04 a � POWER 4 SIGNAL LEG SECTION FI UNIT awnc+x SYMBOL DESCRIPTION RJs KM FEI I DATA RJMS OR/N6E D � GATA BACK-UP RM6 ORANGE O �� U5121tANQ PARTS LIST: 4 PORT Box P/N 4M4 -41P (I) VO" 4 PM 41106 -1tLb (2) DATA JACKS IPM 0 MP& BY %"TOW. 4 PORT JACK 11171 '' TO W WED AT FjWw" NtEi1SM NOT TO SGAL.E ELECTRI 5CHEMATIC SECTIONS o- REC9 56ED MOUNTED OUTLETS INSTALLED BACK CK WALL AS A T 4 SHOW FIELD VERIFY EXACT LOCATION. CABINETRY GONTR. TO PROVIDE GUT OUT BACK PANEL IN +q" t71 ib INALL CASE FOR OUTLETS, PROVIDE ACCESS THRI! GASH L MAP UNIT 4 SHOY''IGASES FOR SHOWCASE L16HT I TERMINAL INSTALLATION, HOOK UP ! INTERCC ECTION REGE55ED MTV OUTLETS INSTALLED IN FACE OF DEMISING WALL OF TONER CABINET FOR MUSIC SYSTEM. CABINETRY CONTRACTOR TO PROVIDE 12"14 x 18"W GUT -= PAft FOR AC41 '.�i, EIRED IN WIDTH OF . -- UNIT AT +600AFF. CE R �ZG pN1P �,,p,N 1 � 204 04 a � POWER 4 SIGNAL LEG SECTION FI UNIT awnc+x SYMBOL DESCRIPTION REGE SM DUPLEX ELEGTRIGAL CONVENIENCE OUTLET N�TED HMZONTALLY AT 2 1/2 "AFF. CENTERED IN 5 "H V4000 BASE � (UNLESS OT USE NOTED). RECESSED DUPLEX ELEGTRIGAL CONVENIENCE OUTLET t I TED VERTICALLY AT + 13" AFF (UNLESS OTHERWISE NOTED) RECESSED 996280 FY ELECTRICAL OUTLET MOIMTED 4 VERTICALLY AT + 16" AFF (UNLESS OTHERWISE NOTED) 19 ELEGTRIGAL JUNCTION BOX MOUNTED AT HEIGHT AS NOTED ON PLAN REGE55ED 5 &AN& WALL BOX MOUNTED AT + 4" AFF • O Q P.0.5. TERMINAL pi 16 DEDICATED CIRCUIT FOR ELECTRIC -DATA- TEL.EPI•IONE O FEGE SED M RESISTER .JACK. SEE DETAIL THIS DM. DI 0 CENTRAL PATC 41NCP STATION. SEE DETAIL THIS PM. 02 RECESSED WALL TELEPHONE JA XS MOUNTED VERTICALLY AT HE16HT5 1 AS NOTED ON PLAN TO BE SUPPLIED 4 INSTALLED BY ON SITE 6.C. 3 PHONE JACKS REGI"D: SALES COUNTER ( I PHONE + I COMPUTER,) STORASE ROOM M 6f L DESK (I PHONIES STEREO SPEA KER INPUT ..,LACK PANEL MOUNTED AT + 60" Ad RECESSED IN MALL VOU)ME CONTROL BOX TO CONTROL FITTING ROOM AUD10 SPEAKER ONLY. "RADIO SHACK" GAT. 6-oM3 ® 9 PUSH BUTTON D BUTTON AND OUZZER "EDWARDS" 0 115 -165 IBUZZEFt %0W -,A5E FLUORESCENT L16HT RAIL W/ REMOTE BALLAST, PRE -MRED F IN SHOP. '"5TYLMARK" REFLECTOR SATIN CHROME FINISH - - - - - - - W/ 24" LONS T-6 3000`K FLUORESCENT LAMPS. FIXTURES SUPPLIED AND INSTALLED COh*"LM ISY CABINETRY CONTRACTOR INI ZONNE CTIONS , AND FINAL ELEGTRIGAL MOCK UP BY ON 51TE 4►.C. ROTES ALL DUPLEX OUTLETS, MALL SftTC CS, DI MMER Ci WROLS, PHONE .JACKS, � r , MALL 4E AND ALL EXPOSED El TRICAL DEVICES TO BE I rV IVORY COLOR 5A ZLITE COVER PLATES+ JUN , I ALL r�LL MTD SNITCHES i GONTR X5 TO BE ZD�Q INSTALLED AT +48 MAX R ALL L16NT FIXTURES CGN'IrLEM I"ITM LAMPS TO BE WgFLIED BY CAGhE. Afti b OT NOTED A w%*v Y. V. KUl KARNi, P.F. 2130 F. ICALFR "FtIVF P"c3eNIX,. AZ 85020 - 4725 PHONE 602 678 5993 PAX 602 678 0530 REVISIONS a m C? � N r x r ,, J a J Illon p x =N "I 400 c 3 a �► � 6 .2 0 Zr c W a O V z UL z q) w O f W in f Z A a in Z t M x =a V 2 V N 0 Ly a W IL ` N = A 0� M W Z U S to O w CID o• i mow • a. O uj �• w, z x r O * 2U57 0 Wsvvs /ONAI. ECG` EXPIRES 4-17-2006 DRAWN CHECKED ATE A T SCALE AS NOTED JOB NO. 03113q SHEET OF SHEETS A '20r r � A '20r REMOVABLE 1/2 CELL SILVER PARACUBE EGGCRATE W/ WALL MTD. LIGHTBOX SUPPLIED BY CABINETRY CONTR. SEE THE ARCHITECTURAL PLANS FOR EXACT PLACEMENT OF THESE TYPE ' C' FIXTURES. DO NOT SCALE THESE DRAWINGS FOR PLACEMENT OF FIXTURES 24 "x48" ACOUSTIC TILE LAY -IN CEILING AT +11' -6 AFF® 1 1/2 MTL CHANNEL AT 48 - 0.C. MAX 7/8 MTL CHANNEL AT 24 O.C. MAX WPM MEN I MEN rA F. MENOMINEE r4 � RL FAME a All I FIXTURE SOFFIT UGHTCOVE I BOTTOM AT + 8' -7" AFF. - PREFINISHED WHITE 00011 FA A -`, 1' -5? 4' -0 4' -0 4' -0- A Al GYP. BD. CEILING AT + 8' -0 AFF. ° A 2 PAINT ©� • G 4' -0" 4' -0 4'- Al A GYP. 80. CEILING AT +10' -O' AFF. PAINT 6O A �► ..*tip.. .` .— ..�� C GYP. 9D SOFFIT BOT. AT A9 A6 +9' -0' AFT. PAINT WHITE TYP_ AT IQ SIDES STEPPED FIXTUM SOFFIT GYP. BD HEADER 90T. AT RECESSED CLG MTO ELECTRICAL WOOD FINISH +8' - AFF. PAINT FINISH O DUPLEX OUTLET r F1 4' -0 L 4' -0 6 " A D l 2' -8" 2' -8 ,��,, A 3 I REFLECTED CEILING PLAN 1/4 = 1' -0" CONSTRUCTION NOTES: 1. * SYMBOL INDICATES EMERGENCY LIGHTING LOCATIONS. REFER TO LIGHTING LEGEND THIS DRAWING FOR FIXTURE SPECS. 2. ON SITE G.C. TO PROVIDE ACCESS TO ALL DUCTWORK, HEATERS, PIPING, CONTROLS, OR VALVES LOCATED WITHIN THE PREMISES (WHETHER TENANT OR BASE BUILDING SYSTEMS) BY MEANS OF ACCESSIBLE CEILING TILE OR FLUSH ACCESS PANELS. 3. CEILING SYSTEMS TO BE SUSPENDED FROM STRUCT. STEEL ONLY. CONNECTION TO LANDLORD'S METAL DECK IS NOT PERMITTED. 4. ALL CEILING SYSTEMS TO HAVE 1 HR FIRE RATING. FACE OF GYP, DEMISING PAR TYPE F1 OR F (REFER TO PL SINGLE TUBE FIXTURE GYP. BO. W/ PAINT FINISH 2 1/ (20 G METAL STUD a ♦ ` +10' -0 AFF Ak TYPE wXw BD, PAINT A5 A27 STEPPED FIXTURE SOFFIT s WOOD FINISH Og METAL STUD (20 GA) FRAMING FACE OF GYP. BD DEMISING PARTITION SINGLE TUBE FLUOR. LIGHT FIXTURE WHITE MELAMINE 5E C TI ON 2 STEPPED F SCIA, WI �0D FINIS 9 I I r � BOT. OF DECK ABOVE 1 1/2 MTL CHANNEL AT 48 MAX 7/8 MTL CHANNEL AT 24 Q.C. MAX -` +10' -0" AFF 5/8 TYPE - X - GYP. BO, PAINT 6� STORAGE ROOM RECESSED 2 X 4 LAY -IN 2 -LAMP FLUORESCENT LIGHT FIXTURE W/ ELECTRONIC BALLAST, ACRYLIC LENS, & T -8 30001K LAMPS "COLUMBIA - FL.2L2X4TRELE (OR APPROVED EQUAL) MASTER SHUT -OF SWITCH FOR ALL LIGHTING SALES FLOOR WALL OR CEILING MOUNTED EMERGENCY EXIT LIGHT SIGN FIXTURE W/ BATTERY BACK -UP. CLEAR ACRYLIC PANEL W/ RED LETTERS & WHITE FACE PLATE. - LIGHTALARMS /SPLEDWRCD (OR APPROVED EQUAL) STORAGE ROOM UNIVERSAL MOUNT EMERGENCY LIGHT & EXIT SIGN FIXTURE W/ BATTERY BACK -UP. "PRESCOLITE #IAPEXHC3RECCBW (OR APPROVED EQUAL) RECESSED CEILING MOUNTED AUDIO SPEAKER WITH GRILLE. - POSH 5.25 RETRO CEILING SPEAKER FOR INSTALLATION IN CEILING TILE OR SHEET ROCK, PREFINISHED WHITE GRILLE & BEZEL, SELF CONTAINED IN STEEL HOUSING AVAILABLE FROM: 'DMX MUSIC" PH: (206)329 - 1400 SPEAKER W/ GRILLE SUPPLIED BY CACHE INSTALL W/ 16 GA /WT /162 WIRE SAME AUDIO SPEAKER & GRILLE SPEC AS ABOVE - EXCEPT W/ BUILT -IN THUMB SCREW VOLUME CONTROL. NOTE: ALL LIGHT FIXTURES COMPLETE WITH LAMPS TO BE SUPPLIED BY CACHE. UNLESS OTHERWISE NOTED ABOVE RECE�vE:. CACHE. ( UNLESS INCOMPLETE r ITV CW r, W • Ju LTR# PERMIT CE% Y. V. KULKARNI, P.E. 2130 E. KAL.1 -R DRIVE PHOENIX,. .AZ R5020 -4725 P"C3W E 602 fi► 7 R 5993 fiA X 602 67JR 0530 REVISIONS BY N1 CITY REVIEW YVK D RAW N CHECKED DATE I SCALE AS NOTED JOB NO 031139 SHEET E -2 OF A SHEETS Lop w A29 ' GYP. BD. CEILING AT A3 DESCRIPTION +8' -3 V8 AFF. RECESSED COMPACT FLUORESCENT 1 LAMP 7 OPEN REFLECTOR DOWNUGHT W/ CLEAR ALZAK CONE PAINT 6 & WHITE FLANGE, INTEGRAL ELECTRONIC BALLAST - UGHTOUER" 17142BU/8037CLW/1951 (OR LIGHTING ENERGY COMPLIANCE INFORMATION APPROVED EQUAL) W/ (1) PHILIPS PLT26W /35/4P 3000' LAMP NAME OF PROJECT : CACHE, SOUTH CENTER, SEATTLE, WASHINGTON 4' -0 4' -0 INTERIOR AREA 1602 SQ. FT. = 1602 X 1. 5 = 2403 W OWNER 1 -6i - LIGHTING WATTAGE ALLOWANCE FOR INTERI ❑R AT 1.5 W /SQ. FT. Al WALL DISPLAY AREA 1326 SQ. FT. X 1. 5 W /SQ. FT. = 1989 W FLOOR DISPLAY AREA 640 SO. FT. X 1.5 W /SQ. FT. = 960 W TOTAL WATTAGE ALLOWED FOR THE INTERIOR LIGHTING = 5352 W ONSW x ONE CIRCUIT TO ENERGIZE BATTERY PACK CONTINUOUSLY FIXTURES U INSTALLED LIGHTING FOR THE INTERIOR * FIXTURE TYPE WATTAGE /FIXTURE NO. OF TOTAL WATTAGE * A 28 23 644 RECESSED LINEAR HOUSING W/ (2) ADJUSTABLE PAR30 HALOGEN TRACK HEADS WHITE HOUSING do - Al 28 8 224 CHANNEL LETTER ILLUMINATED SIGN C 100 24 2400 A q l `- o B SHOW WINDOW LIGHTING EXEMPT FROM THE CALCS. RECESSED INCANDESCENT PAR ADJUSTABLE ACCENT LIGHT W/ FLUSH LAMP HOUSING & 6 3/4 D 75 5 375 U n E 75 5 375 FIXTURE TO BE CAPABLE OF 35' ADJUSTABILITY IN FULLY RECESSED POSITION. FLU❑ STRIP IN COVE "LIGHTOLIER /1102P1 /1148 (OR APPROVED EQUAL) W/ (1) PHIUPS 60PAR38/HAL/NSP10 LAMP SINGLE LAMP 35 30 1050 RECESSED INCANDESCENT PAR LAMP 5 OPEN REFLECTOR DOWNLIGHT H 70 4 280 INDICATES CENTER LINE OF MANUAL TOTAL INSTALLED LIGHTING FOR INTERIOR 5348 WATTS (OR APPROVED EQUAL) W/ PHILIPS 60W PAR30 S/H/NFL LAMP INSTALLED LIGHTING WATTAGE AT 5348 IS LESS THAN ALLOWED WATTAGE AT 5352. XXIr NNUMON Al Please feel free to call me i f you should need any more i nform at i on. My phone number is 602 678 5993. Thank you. SOT. OF DECK ABOVE U REVISED THE LIGHTING PLAN AND LIGHTING FIXTURE SCHEDULE SO THAT IT COMPLIES WITH THE WASHINGTON ENERGY CODE. CHANGED FIXTURES A, Al, DELETED TRACK IN THE SALES AREA AND REPLACED WITH TYPE #C' FIXTURES. AT BOTH SN & 5/8 GYP. 80 CLG AT +11' -2 7 /8'AFF. PAINT FIMSO& 2• 4' TYP. AT BOTWSIOES 5/8' TYPE - X' GYP. 80 - - - — — - - — — = SOFFIT W/ SLOPED FACE, PAINT FINISH C C N E 5/8' TYPE - X - GYP. BD PAINT T g FINI SH -��. :- • IIIWI A E B FLUSH 18 x 18" ACCESS DOOR MM IN ENTRY SOFFIT. - MILCOR' STYLE ATR W/ • n CYLINDER KEY LOCK. FIELD INSTALL GYPSUM G DESCRIPTION A0 RECESSED COMPACT FLUORESCENT 1 LAMP 7 OPEN REFLECTOR DOWNUGHT W/ CLEAR ALZAK CONE & WHITE FLANGE, INTEGRAL ELECTRONIC BALLAST - UGHTOUER" 17142BU/8037CLW/1951 (OR APPROVED EQUAL) W/ (1) PHILIPS PLT26W /35/4P 3000' LAMP BOARD FACING & CASING BEADS, FINISH TO 4' -0 4' -0 4' -0 4' -0' L 4' -0 1 -6i - Al Al FI MATCH SOFFIT.TO SERVICE RO LLING APPROVED EQUAL) W/ (1) PHILIPS PLT26W /35/4P 3000' LAMP ° FITTING ROOM EMERGENCY LIGHTING IN RECESSED CEILING COMPACT FLUOR. UGHT FIXTURE. SAME SPEC AS FIXTURE - A1" ABOVE EXCEPT W/ EMERGENCY PACK OPTION. 2 CIRCUITS REQUIRED EX ONE CIRCUIT TO ENERGIZE BATTERY PACK CONTINUOUSLY 1 g1 U GRILLEANO SIGNAGE. g * i * C ® RECESSED LINEAR HOUSING W/ (2) ADJUSTABLE PAR30 HALOGEN TRACK HEADS WHITE HOUSING do - CHANNEL LETTER ILLUMINATED SIGN A l A q l `- o A RECESSED INCANDESCENT PAR ADJUSTABLE ACCENT LIGHT W/ FLUSH LAMP HOUSING & 6 3/4 V -4i U n ON TIME CLOCK CIRCUIT FIXTURE TO BE CAPABLE OF 35' ADJUSTABILITY IN FULLY RECESSED POSITION. :- "LIGHTOLIER /1102P1 /1148 (OR APPROVED EQUAL) W/ (1) PHIUPS 60PAR38/HAL/NSP10 LAMP E O RECESSED INCANDESCENT PAR LAMP 5 OPEN REFLECTOR DOWNLIGHT INDICATES CENTER LINE OF MANUAL (OR APPROVED EQUAL) W/ PHILIPS 60W PAR30 S/H/NFL LAMP F1 SINGLE TUBE FLUORESCENT LIGHT STRIPS 2'. 3', 4', & 6' LENGTHS - MERCURY UGHTTNG Al n OPERATED ROLLING GRILLE CURTAIN c U AS MFR. BY METRO DOOR. 800.669.3667 �- t EXT. 238 ATTN. BETH KRANTZ 10 I B " E LI E a BORDER ON G� BD 40 RECESSED 5/8' SO. E METAL REVEAL CHANNEL FINISH �5 TYP AT BOTH SIDES 2' 3' 2' 'FF — 3' 3' — 4' 1 — L F1 _rF2 BOTTOM OF SHOW WINDOW HEADER AT +10' -2 7/8 - AFF COV'D. W/ LIMESTONE FACING 40 TYP AT 907H SIDES M a npfi an A 1 9 CODL'M 11 LMCE A25 APPROVED JUL 1 3 2004 City Of TUkwila BUILDING DIVISION LIGHTIN LEGEND SYMBOL DESCRIPTION A0 RECESSED COMPACT FLUORESCENT 1 LAMP 7 OPEN REFLECTOR DOWNUGHT W/ CLEAR ALZAK CONE & WHITE FLANGE, INTEGRAL ELECTRONIC BALLAST - UGHTOUER" 17142BU/8037CLW/1951 (OR APPROVED EQUAL) W/ (1) PHILIPS PLT26W /35/4P 3000' LAMP A. SALES FLOOR EMERGENCY LIGHTING IN RECESSED COUNG COMPACT FLUOR. UGHT FIXTURE. SAME SPEC AS FIXTURE 0 A1 0 ABOVE EXCEPT W/ EMERGENCY PACK OPTION. 2 CIRCUITS REQUIRED - ONE CIRCUIT TO ENERGIZE BATTERY PACK CONTINUOUSLY Al RECESSED COMPACT FLUORESCENT 1 LAMP 7" OPEN REFLECTOR DOWNUGHT W/ CLEAR ALZAK CONE do WHITE FLANGE. INTEGRAL ELECTRONIC BALLAST "UGHTOUER" #7142BU/8037CLW/1951 (OR APPROVED EQUAL) W/ (1) PHILIPS PLT26W /35/4P 3000' LAMP Al FITTING ROOM EMERGENCY LIGHTING IN RECESSED CEILING COMPACT FLUOR. UGHT FIXTURE. SAME SPEC AS FIXTURE - A1" ABOVE EXCEPT W/ EMERGENCY PACK OPTION. 2 CIRCUITS REQUIRED ONE CIRCUIT TO ENERGIZE BATTERY PACK CONTINUOUSLY 1 g1 "UGHTOUER" SURFACE CEILING MOUNTED SHOW WINDOW UGHT TRACK, WHITE FINISH W/ "LIGHTOUER - 3 08 296 01 METAL HAUDE PAR30 LYTESPAN SOF -TECH LAMP HOLDERS WHITE FINISH W/ PHILIPS /CDM70/PAR30L/M/FL 3000'K METAL HALIDE LAMPS. C ® RECESSED LINEAR HOUSING W/ (2) ADJUSTABLE PAR30 HALOGEN TRACK HEADS WHITE HOUSING do - TRACK HEADS W/ TRIMLESS FLANGE CONTECH LIGHTING #RAN7530 -X2 -P (OR APPROVED EQUAL) W/ (2) PHILIPS 50PAR30S/HAL/FL40 LAMPS RECESSED INCANDESCENT PAR ADJUSTABLE ACCENT LIGHT W/ FLUSH LAMP HOUSING & 6 3/4 D6 RECESSED ADJUSTABLE CLEAR ALZAK REFLECTOR BAFFLE W/ WHITE FLANGE. FIXTURE TO BE CAPABLE OF 35' ADJUSTABILITY IN FULLY RECESSED POSITION. "LIGHTOLIER /1102P1 /1148 (OR APPROVED EQUAL) W/ (1) PHIUPS 60PAR38/HAL/NSP10 LAMP E O RECESSED INCANDESCENT PAR LAMP 5 OPEN REFLECTOR DOWNLIGHT W/ CLEAR ALZAK CONE do WHITE FLANGE. - LIGHTOLIER" #1002P1/1013 (OR APPROVED EQUAL) W/ PHILIPS 60W PAR30 S/H/NFL LAMP F1 SINGLE TUBE FLUORESCENT LIGHT STRIPS 2'. 3', 4', & 6' LENGTHS - MERCURY UGHTTNG = = :4 MM SERIES (OR APPROVED EQUAL) W/ ELECTRONIC BALLAST & T -8 3500'K LAMPS SECTION ,- - r -Nr It qKr 0 a CU Ci bi C) L, c CU 0) it t3 10 Q m w b a, r r a m H m PANEL 'A', 200 AMPS 120/208 V, 3 PH, 4 W MOUNTING AS SHOWN PANEL TYPE BOLT -ON BRKR RATING 10K AIC. LOCATION AS SHOWN 150 A. M. C. B. NEMA 1 Y. V. KULKARN I . P. E... PHOENIX, ARIZ. 678 -5993. COPYRIGHT 2003 JUNE 14, 2004 PROJ #04F99 CACHE, SOUTHCENTER, TUKWILLA, WA USE N. L. /E. L. LIGHTS LIGHTS LIGHTS TRACK LIGHTING TRACK LIGHTING TRACK LIGHTING TRACK LIGHTING TRACK LIGHTING TRACK LIGHTING TRACK LIGHTING TRACK LIGHTING WINDOW LIGHTS COVE LIGHTING COVE LIGHTING STOCK ROOM NEW 7 -1/2 TONS RTU W /12 KW ELECT HEAT 48.9 MCA, 50 MDCP VERIFY DETAILS OF UNIT INSTALLED IN THE FIELD. C. B. 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 50/3 CKT. A B C CKT NO. CODE LOAD EXTERIOR WALL PACK 15063 14328 15343 NO. 1 500 Q • -- 44734 TOTAL CODE LOAD NOTED ON DRAWINGS 1200 -- -- 2 3 -- 1000 -- 1200 3) OUTLETS, MISC. = 200 -- 4 5 -- -- 820 0 7) - -- 400 6 7 1000 -- -- 'HUBBELL' #B2429 BOX WITH X53825 400 -- -- 8 9 -- 1080 -- FLUSH FLOOR TELEPHONE OUTLET - SMOKE DETECTOR -- 400 -- 10 11 -- -- 1800 COVER PLATE AT +18' OR AS NOTED WITH BATTERY PACK) -- -_ 400 12 13 1800 -- -- PULL WIRE TO TELEPHONE MOUNTING 400 -- -- 14 15 -- 1800 -- TO EQUIPMENT AS NOTED Q * -- 400 -- 16 17 -- -- 1800 EQUAL ,• -'-'� • -- _- 400 18 19 720 -- -- INDICATES HOMERUN TO PANELBOARD 800 -- -- 20 21 -- 1080 -- MOTOR CONTROLLER - FURNISHED WITH MOTOR 800 -- 22 23 -- -- 1800 -- -_ 400 24 25 360 _- 400 -- -- 26 27 -- 840 -- -- 400 -- 28 29 -- -- 840 -- -- 400 30 31 600 -- �-- 400 -_ --- 32 33 ---- 5868 -- -- -- 34 35 -- -- 5868 36 37 5868 -- -- -- -- 38 39 -- -- -_ -- 40 41 42 C. B. 20/1 2011 20/1 2011 2011 2011 20/1 20/1 20/1 2011 20/1 20/1 2011 20/1 2011 20/1 20/1 20/1 20/1 20/1 2011 USE SIGN VIA T. C. SECURITY SYSTEM OUTLETS P. 0. S. OUTLETS OUTLETS OUTLETS OUTLETS OUTLETS OUTLETS OUTLETS OUTLETS MGR DESK OUTLETS MGR DESK OUTLETS MGR DESK OUTLETS T. M. B. SPARE SPARE SPARE SPARE SPARE IN • r 1 1 ELECTRICAL SYMBOLS LIST ALL SYMBOLS MAY NOT APPLY TO THIS PROJECT. CONNECTED LOAD FLUORESCENT LIGHTING FIXTURE - AS 14448 13868 14928 • NOTED ON DRAWINGS CODE LOAD EXTERIOR WALL PACK 15063 14328 15343 43244 TOTAL CONNECT. LOAD CODE LOAD AMPS Q • 126 120 128 44734 TOTAL CODE LOAD NOTED ON DRAWINGS CODE LOAD SUMMARY BY LOAD TYPES • FIXTURE - AS NOTED ON DRAWINGS 1) LIGHTS = 7450 2) SIGN = 1200 3) OUTLETS, MISC. = 6600 4) SPARE - 0 5) HVAC = 17604 6) H. W. H. = 0 7) EQUIPMENT = 0 8) TRACK LGTS = 11880 IN • r 1 1 ELECTRICAL SYMBOLS LIST ALL SYMBOLS MAY NOT APPLY TO THIS PROJECT. TMB • MOTOR CONTROLLER - FURNISHED AND FLUORESCENT LIGHTING FIXTURE - AS �% • NOTED ON DRAWINGS • EXTERIOR WALL PACK • WALL MOUNTED LIGHTING FIXTURE - AS NOTED ON DRAWINGS Q • CEILING MOUNTED LIGHTING FIXTURE - AS M NOTED ON DRAWINGS © INDICATES NIGHTLIGHT OR EMERGENCY • FIXTURE - AS NOTED ON DRAWINGS • DUPLEX CONVENIENCE OUTLET MOUNTED • AT +18 OR AS NOTED 40= • FOURPLEX RECEPTACLE, MOUNTED 4 ? • AT +18" OR AS NOTED : * DUPLEX CONVENIENCE OUTLET MOUNTED $3 • ABOVE COUNTER. VERIFY EXACT MOUNT- Qq • ING HEIGHT WITH ARCHITECTURAL ELEV. ® • SPECAL OUTLET AS NOTED ON DWGS 10 • DEDICATED OUTLET AT +18" OR AS $D • NOTED. "HUBBELL' jpG5262 (ORANGE) RECEPTACLE WITH ISOLATED GROUND ® • FLUSH FLOOR POWER OUTLET - 'HUBBELL' #B2429 BOX WITH X53825 COVER PLATE. DUPLEX GROUNDING TYPE M • RECEPTACLE AND JIS3082 CARPET Q • FLANGE IN ALL CARPETED AREAS. 0 • Ego FLUSH FLOOR TELEPHONE OUTLET - SMOKE DETECTOR "HUBBELL' X2427 BOX WITH #S2425 DUCT SMOKE DETECTOR COVER PLATE AND #53082 CARPET HEAT DETECTOR FLANGE IN ALL CARPETED AREAS r} • INDICATES TELEPHONE TYPE BOX AND EMERGENCY LIGHT (UNSWITCHED FIXTURE COVER PLATE AT +18' OR AS NOTED WITH BATTERY PACK) FOR DATA TERMINAL OR CRT. PROVIDE CABLE AND/ OR CONDUIT AS NOTED ` * TELEPHONE OUTLET AT +18" OR AS NOTED. FURNISH (1) 3/4" CONDUIT WITH PULL WIRE TO TELEPHONE MOUNTING BOARD OR AS NOTED J� • JUNCTION BOX IN ACCESSIBLE LOCATION JUNCTION BOX IN ACCESSIBLE LOCATION WITH FLEXIBLE CONDUIT CONNECTION TO EQUIPMENT AS NOTED Q * PHOTOCELL ON ROOF (AIM NORTH). TORK #2101 OR APPROVED EQUAL • ASTRONOMIC 3 POLE LIGHTING TIME - SWI"fCH. TORK #730OZ OR APPROVED EQUAL ,• -'-'� • INDICATES CIRCUIT IN CONDUIT RUN IN FLOOR OR UNDERGROUND • INDICATES CIRCUIT IN CONDUIT CON- CEALED IN WALLS OR ABOVE CEILING * INDICATES HOMERUN TO PANELBOARD OR AS NOTED G • PANELBOARD - MOUNT AT +6' -6" TO TOP -� STRIP HEATER WITH CONTACTOR ® * MOTOR CONTROLLER - FURNISHED WITH MOTOR O • WATER FLOW SWITCH TS • TAMPER SWITCH TMB • MOTOR CONTROLLER - FURNISHED AND ® • INSTALL BY ELECTRICAL CONTRACTOR. SIZE AS NOTED • MOTOR - SIZE AS INDICATED ON DWGS. • DISCONNECT SNITCH - SIZE AND FUSES AS PER MANUFACTURER'S RECOMMENDAT- XP • IONS ( WEATHERPROOF WHERE OUTSIDE) M WEATHERPROOF (RAIN nGHT) • H.P. RATED MANUAL MOTOR STARTER EDF • (W.P. WHERE OUTSIDE) UNO * UNLESS NOTED OTHERWISE • SINGLE POLE SWITCH MTD. AT +44" OR EF • AS NOTED 4 ? • TWO POLE SWITCH MOUNTED AT +44" OR �- • AS NOTED $3 • THREE WAY SNITCH MOUNTED AT +44" OR Qq • AS NOTED $4 • FOUR WAY SNITCH MOUNTED AT +44" OR • AS NOTED $D • SINGLE POLE SNITCH W/ PILOT LIGHT AT +44" OR AS NOTED IF♦ • INCAND. SLIDE CONTROL DIMMER AT +52" OR AS NOTED (2000 WATT) TMB • 3/4" PLYWOOD TELEPHONE MOUNTING BOARD WITH 06 CU. GROUND AND DEDICATED DUPLEX CONY. OUTLETS AS SHOWN ON PLANS. FURNISH IN ACCORDANCE WITH TELCO REQUIRE - MENTS. SIZE AS NOTED XP • EXPLOSION PROOF WP • WEATHERPROOF (RAIN nGHT) SES • SERVICE ENTRANCE SECTION EDF • ELECTRIC DRINKING FOUNTAIN UNO * UNLESS NOTED OTHERWISE D • CONDUIT EF • EXHAUST FAN -- 150 WATT, 120V. UNLESS OTHERWISE NOTED �- • CONDUIT TURNING UP 0 • CONDUIT TURNING DOWN Qq • EMERGENCY EXIT SIGN, SEE LIGHTING FIXTURE SCHEDULE FOR SPECIFICATION • DUAL HEAD EMERGENCY BATTERY PACK, SEE LIGHTING FIXTURE SCHEDULE FOR SPECIFICATION 4 • DUAL HEAD RECESSED EMERGENCY PACK, SEE LIGHTING FIXTURE SCHEDULE FOR SPECIFICATION M • FIRE ALARM PULL STATION O +42" A.F. Q • HORN/ STROBE COMBINATION (FIRE ALARM) 0 • STROBE ONLY UNIT (FIRE ALARM) • SMOKE DETECTOR <#> • DUCT SMOKE DETECTOR a • HEAT DETECTOR HL NIGHT LIGHT (UNSWITCHED FIXTURE) EL EMERGENCY LIGHT (UNSWITCHED FIXTURE WITH BATTERY PACK) FEEDER AND DISCONNECT SCHEDULE AND NOTES. I. USE #14 COPPER WIRE AS MINIMUM FOR 15 AMPS CIRCUITS. 2. USE #12 COPPER WIRE AS MINIMUM FOR 20 AMPS CIRCUITS. 3. USE #10 COPPER WIRE AS MINIMUM FOR 25 AMPS CIRCUITS. 4. USE #10 COPPER WIRE AS MINIMUM FOR 30 AMPS CIRCUITS. 5. USE #8 COPPER WIRE AS MINIMUM FOR 35 AMPS TO 45 AMPS CIRCUITS. 6. USE #6 COPPER WIRE AS MINIMUM FOR 50 AMPS CIRCUITS. 7. PROVIDE PROPER DISCONNECTS, FUSES AND OTHER FEATURES FOR LOADS SUCH AS A. C. EQUIPMENT. VERIFY EXACT DETAILS OF THE ACTUAL UNITS THAT WILL BE INSTALLED SO THAT PROPER SIZE FEEDER AND FUSES CAN BE FURNISHED TO MATCH THE ACTUAL UNITS THAT WILL BE INSTALLED. PROVIDE PROPER GROUNDING AS PER N. E. C., 8. FOR EACH ELECTRIC WATER HEATER PROVIDE DISCONNECT AT WATER HEATER AS PER N. E. C. 9. PROVIDE 120 VOLTS, WP, GFCI OUTLET WITHIN 25 FEET OF MECHANICAL EQUIPMENT. 10. ALL OUTDOOR ELECTRICAL EQUIPMENT TO BE NEMA 3R. 11. PROVIDE BOND WIRE IN ALL E.M.T. CONDUIT AS WELL AS IN ALL PVC OR NON- METALLIC CONDUITS. SIZE BOND WIRE AS PER N. E. C.- UPTO 20 AMPS CIRCUIT : #12 BOND WIRE 25 THRU 60 AMPS CIRCUIT: #10 BOND WIRE 65 THRU 100 AMPS CIRCUIT: #8 BOND WIRE 110 THRU 200 AMPS CIRCUIT: #6 BOND WIRE 13. EXACT PLACEMENT AND HEIGHTS OF ELECTRICAL OUTLETS, SWITCHES ETC. TO BE COORDINATED IN THE FIELD WITH THE ARCHITECT BEFORE ROUGH -IN. 1!)U qmo REVIEW E ONCE CODE COMP APMOVED JUL 13 2004 City Of Tukwila BUILDING DNISION V. V. xUt_K_ARNi, P.E. 213 0 E. KALEK DRIVE PHOENIX,. AZ 85020 -4723 PNC3WE 60 6 78 3993 FAX 602 678 0 530 0 • ELECTRICAL NOTES 1. ALL WORK TO BE IN ACCORDANCE WITH THE N.E.C. AND ALL APPLICABLE RULES, REGULATIONS AND ORDINANCES. 2. ALL WIRE TO BE COPPER THW, THWN, THHN OR XHHW, #12 MIN. ALL CONDUITS TO BE EITHER RIGID OR EMS AS ALLOWED BY THE CODES. ALL EMT CONDUITS MUST HAVE BOND WIRE SIZED AS PER NEC. 3. ALUMINUM CONDUCTORS ARE NOT ALLOWED. 4. VERIFY THE STRUCTURAL, CEILING AND OTHER DETAILS THAT MAY AFFECT THE MOUNTING AND PLACEMENT OF LIGHTING FIXTURES. VERIFY THE RECESSED FIXTURES TO ASCERTAIN THAT THEY WILL GO WITH THE CEILING OR WALL DETAILS ALL FIXTURES TO BE MOUNTED IN A NEAT, EYE - PLEASING MANNER AT HEIGHTS AND LOCATIONS THAT ARE SUBJECT TO THE FINAL CONFIRMATION BY THE OWNER OR ARCHITECT IN THE FIELD. 5. PROVIDE DISCONNECTS, FUSES, OVERLOAD PROTECTION AND PROPER CONTROL & POWER WIRING FOR OTHER EQUIPMENT SUCH AS HVAC, MECHANICAL AND ANY OTHER SPECIAL EQUIPMENT THAT MAY BE USED FOR THIS PROJECT. VERIFY THE ROUGHIN DETAILS, ACTUAL LOCATIONS, WIRE SIZES AND ANY OTHER DETAILS WITH THE RESPONSIBLE TRADES AND FOLLOW THE ACTUAL INSTALLATION INSTRUCTIONS FOR THE EQUIPMENT BEING INSTALLED. CO- ORDINATE WITH THE OTHER TRADES. 6. ALL DISCONNECTS, FIXTURES, AND OTHER ELECTRICAL COMPONENTS THAT ARE SUBJECT TO THE OUT SIDE WEATHER ELEMENTS MUST HAVE THE WEATHERPROOF ENCLOSURES. 7. FOR HOMERUNS OVER 65 FEET, USE ONE SIZE LARGER WIRE. FOR HOMERUNS OVER 115 FEET, USE TWO SIZE LARGER WIRE. 8. PROVIDE PROPER GROUNDING FOR ALL EQUIPMENT, RACEWAYS ETC. AS PER NEC. 9. ALL BREAKERS THAT ARE TO BE USED TO SUPPLY LIGHTING LOADS MUST BE RATED FOR SWITCHING DUTY. PROVIDE LOCK -ON DEVICES FOR THE NIGHT LIGHT CIRCUIT AND OTHER CIRCUITS THAT MAY BE SO DIRECTED BY THE ARCHITECT. 10. SIGN CIRCUITS MUST BE IN ACCORDANCE WITH THE NEC ARTICLE 600 WITH SPECIAL REFERENCE TO 600 -2 FOR THE DISCONNECT REQUIRED. ELECTRICAL SINGLE LINE DIAGRAM EXISTING 120/208 VOLTS, 3 PHASE, 4 WIRE SERVICE BY THE LANDLORD. COORDINATE WITH THE MALI FOR ALL SERVICE DETAILS IN THE FIELD. M METER AS PER THE MALL SPECS AND DETAILS. VERIFY THE DETAILS OF THE EXISTING METER AND REUSE /UPGRADE THE SAME AS NEEDED FOR THE NEW TENANT, 200 AMPS /3 POLE DISCONNECT WITH 150 AMPS FUSES AS PER THE MALL SPECS AND DETAILS. FEEDER TO PANEL 'A', 4 - #4/0 THWN COPPER, 1 - #6 COPPER GROUND, 2.5' CONDUIT. VERIFY ROUTING OF THE CONDUIT IN THE FIELD WITH THE MALL. REUSE EXISTING CONDUIT IF POSSIBLE. FEEDER IS OVERSIZED TO MINIMIZE VOLTAGE DROP. PANEL 'A'.. 200 AMPS, 120/208 VOLTS, 3 PHASE, 4 WIRES. ELECTRICAL LOAD CALCS LIGHTS AT 125% SIGN AT 100% OUTLETS, MISC LOAD HVAC HOT WATER TRACK LIGHTS TOTAL CODE LOAD CODE LOAD AMPS AT 120/208 VOLTS, 3 PHASE, 4 WIRES 7450 VA 1200 VA 6600 VA 17604 VA NONE 11880 VA 44734 VA 124.3 AMPS • i REVISIONS I 6 v I I DRAWN CHECKED DAT 4 1 S o SCALE A5 NOTED JOB NO. 03 � 13q SHEET OF SHEETS • It