HomeMy WebLinkAboutPermit B96-0030 - GROUP HEALTH COOPERATIVE - STORAGE RACKSCity of Tukwila L. L (206) 431 -3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 RACK STORAGE PERMIT Permit No: B96 -0030 Type: B -RACKS Category: Address: 12400 EAST MARGINAL WY S Location: Parcel #: 734060 -0480 Zoning: M1 Contractor License No.: LEASECL118NB TENANT GROUP HEALTH COOPERATIVE 12400 EAST MARGINAL WY S, TUKWILA WA OWNER GROUP HEALTH COOPERATIVE JIM DOUMA PROPERTY MGMT, 521 WALL ST, CONTACT BRIAN BERG NBJJ, 111 S JACKSON, SEATTLE WA 98104 CONTRACTOR LEASE CRUTCHER LEWIS;: Phone: 206 622 -0500 107 SPRING STREET. SUITE 500, 'SEATTLE,.; WA 98104 ************** * * * * * * * * * * * *r4 * * * * * * * * * * * * ** k * ** *-k*'* **** * * * ** k ** * * * * * * * * * * * * ** Permit Description: INSTALL 1.7,064 L.F. OF RACK STORAGE. Status: ISSUED Issued: 02/22/1996 Expires: 08/20/1996 Suite: Phone: (206)448 -4699 SEATTLE WA 98121 Phone: 206 223 -5213 Rack Storage dimensions - Linear ;,Feet 1.72 40 24 201 672 r, Height 8.0 10.0 10.0 8.0 20.0 .0 UBC Edition: 1994 Valu'ation: "`' 2,000.00 Totals 1,376 400 240 1,608 3,440 Total. Permit Fee: ********j k************************************ * * **k * * * * * * * * * * * *k * * * * * * * * * ** '17,064 122:..06 __4;e 12eAYL Permit Cente Authorized ignature a -aa-9() Date I hereby ;certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not The granting of, this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the per •rmance;of work. I am authorized to sign for and obtain this bu,i'di:ng; p j'iit. Signature:__�_ Date: Print Name:_ /�A[714. 12-7//47 Title: This permit shall become null and void if the work is not commenced 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. within DEPARTMENT DATE IN DATE APPROV • R EQUIREMENTS / COMMENTS e BUILDING - initial review —. .16 CE 2 Z q. RO ED) - Z.-- /- • NSULTANT: Date Sent - Date Approved - FIRE PROTECTION: L3 Sprinklers ( ) Detectors N/A Z -- 7 — � INSPECTOR: LGl S/ 0 ,FIRE 2' cA, 3RD NOTIFICATION w INIT: 4 s /b FIRE DEPT. LEI I ER DATED: O PLANNING ZONING: (BAR/LAND USE CONDITIONS? ( -)Yes L3 No REFERENCE FILE NOS.: INIT: MINIMUM SETBACKS: N- S- E- W- O PUBLIC WORKS h5 UTILITY PERMITS REQUIRED? ( ) Yes ( ) No PUBLIC WORKS LETTER DATED: INIT: C OTHER INIT: /1 BUILDING - v w final review . 2.4 / 1 q (i TYPE OF CONSTRUCTION: C � ��� CERT. OFOCCUPANCY? Dyes � No , g UBC EDITION (year): G I ) G j 4 1 . INIT: (C�Z•r -�, BUILDING OFFICIAL i`� V ) 7 - INIT: AMOUNT OWING: CONTACTED I Q fir\ Z 1'C � � l �7� (j�„� Tom' (init.) —. .16 DATE NOTIFIED & -11A-q(40 2nd NOTIFICATION BY: 3RD NOTIFICATION BY: (init.) Qqc) _uilding Permit Application Tracking PLAN CHECK NUMBER gqb -0030 CITY OF TUKWILA Department of Community Development — Permit Center` • 6300 Southcenter Boulevard - #100, Tukwila, WA 98188 (206) 431 -3670 PROJECT NAME r C ro O - ea l - h Coo pe Ct- f-- I ADDESS SUITE NO. SITE go o f fflarst 1 \ S INSTRUCTIONS TO STAFF '� J • Contacts with applicants or requests for information should be summarized in writing by staff so that the status of the project may be ascertained at any time. • Plan corrections shall be completed and approved prior to sending to the next department. • Any conditions or requirements for the permit shall be noted in the Sierra system or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ", date and initial. DEPARTMENTAL REVIEW "X" in box indicates which departments need to review the project. REVIEW COMPLETED r 01/08/93 SITE ADDRESS SUITE # 1400 e Mkgot144 %/TA_ VALUE OF CONSTRUCTION - $ %•_ ASSESSOR ACCOUNT # i 4 . • QO PROJECT �I TYPE WORK: _WA'f NAME/TENANT 'A6._L114_- b41t R � OF LJ New Building LJ Addition LJ Tenant Improvemen Rack Storage 0 Reroof 0 Remodel (residential) (commercial) U Demolition (building) 0 Other DESCRIBE WORK TO BE DONE: lkiaTPU.A.11014 of s1ortbc a letbut.S BUILDING USE (office, warehouse, etc.) OFFICE, 1.A6, PEA t,1 C f , Tic L, A P rm tOWSt WArtti -IojSt 10417 SSi AA Roo lS otivre?AI% rtruin) WA. ST. CONTRACTOR'S LIC # ,— `� L i C L g lib NATURE OF BUSINESS: otebem CAS summit requirements may need to be met. Please explain: 14I1pir EFt. r -04Zl WILL THERE BE A CHANGE IN USE? it No 0 Yes If Yes, new building GgibACIe. Of Use ik170CLIESSE17 Wr714 PSRMI? k....)UARE FOOTAGE - Building: 210aq,31 Tenant Space: Area of Construction: Zois4s0 WILL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE 0 No * Yes IF YES, EXPLAIN: FLM 1MALe PIAZERIALS �.j b tW MA MraALS 10 f ev #43; sicI t FIRE PROTECTION FEATURES: Sprinklers Ill Automatic Fire OR HAZARDOUS MATERIALS IN THE BUILDING? S1or et7 i FL41 i[,QDM. e tnk.WDe akrz oihnIP, ppreR Alarm System j rlAZ11CS PROPERTY OWNER /,.,e,.Up 4 % : cr f S I RCPT # NE 4464145_ ADDRESS WALL Si SeNTIle, Wilk ` Fp96121 __52.1 CONTRACTOR LEb► cgulcum Lewis : 1�A,v� � L GG�•.. PHONE p 4 1 5 EXP. DAT� PHONE 12'S- s Z 1 _ j5i ADDRESS 1 51. SeA flLL WA. ST. CONTRACTOR'S LIC # ,— `� L i C L g lib ARCHITECT -_�� NPSfs�-:. IDN TtG ADDRESS I I 1 ! !TU .1AICLS,o1� I •t tE Wx IZIP -leot DESCRIPTION AMOUNT RCPT # DATE BUILDING PERMIT FEE 1 I.c35 L((o. 31 pc/ I - 3 p /-31 r -?, r PLAN CHECK FEE BUILDING SURCHARGE _ / OTHER: TOTAL - /a R.n(v DGl / "3/ "'TY OF TUKWILA apartment of Community Development - Building Division 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 {= CIS _ 33 IPLAN CHECK NUMBER 1•• • APPLICATION MUST BE FILLED OUT COMPLETELY C ONTACT PERSON A PPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. Handouts are available at the Building counter which provide more detailed information on application and plan submittal requirements. Application and plans must be complete in order to be accepted for plan review. VALUATION OF CONSTRUCTION Valuation for new construction and additions are calculated by the Department of Community Development prior to application submittal. Contact the Permit Coordinator at 431 -3670 prior to submitting application. In all cases, a valuation amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision oy the Building uivisiorr to comply with current fee schedules. BUILDING OWNER / AUTHORIZED AGENT If the applicant is other than the owner, registered architect /engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitations. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Building Code (current edition). No application shall be extended more than once. If you have any questions about our process or plan submittal requirements, please contact the Department of Community Development Building Division at 431 -3670. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT, AND I AM AUTHORIZ D TO APPLY FOR THIS PERMIT. SIGNATURE DATE BUILDING OWNER OR AUTHORIZED AGENT DATE APPLICATION ACCEPTED RECEIVED ATE APPLICATION EXPIRES CITY OF TUKVI,la .JAN 301c96 ;1 - 31 -% PRINT NAME IADDRESS 003 0 LIM 'SEATTLE W14 BUILDINJ PERMIT APPLICATION PERMIT CENTER PHONEitzsz r5 CITY/ZIP c PHONE Z . C...21 9J DOMMERCIAL NEW COMMERCIAL BUILDINGS /ADDITIONS Completed building permit application (one for each structure) Assessor Account Number Two sots (2) of the following: Specifications Structural calculations stamped by a Washington State licensed engineer Li Soils report stamped by a Washington State licensed engineer n Energy calculations stamped by a Washington State licensed engineer or architect Li Legal description Working drawings, stamped by a Washington State licensed ' architect, which include: • Site plan • Architectural drawings • Structural drawings • Mechanical drawings • Elevations • Civil drawings • Landscape plan n Completed utility permit application (one for entire project) • Six (6) sets of civil drawings NOTE :. See utility permit application and checklist for specific utility submittal requirements. RACK STORAGE Completed building permit application I1 Assessor Accavnt Number • Two (2) sets of plans, which include Building floor plan showing: • Entire space where racks will be located • Exit doors • Dimensions of all aisles L J Tenant space floor plan showing rack storage layout, aisles and exits. NOTE: Include dimensions of racks (height, width and length), aisles and exit ways on plan. I Structural calculations stamped by a Washington State licensed engineer (rack storage 8' and over). RESIDENTIAL NEW SINGLE - FAMILY DWELLINGS /ADDITIONS I J Completed building permit application (one for each structure) I Legal description Assessor Account Number I I Topographical survey SUBMITTAL T HE KLI C C S r I Two sets (2) of working drawings, which include: • • Site plan .- -r jOn plan, show closest hydrant location. • Foundation pl ?n • : Include access to o lld+ing, sin_siln; :. • Floor plan width and length of access.) .. • • Roof plan • Building elevations (all views) • Building cross- section • Structural framing plans Washington State Energy Code data Completed utility permit application (� Six (6) sets of site plans showing utilities NOTE: Building site plan and utility site plan may be combined. See utility permit application and checklist for specific submittal requirements. Additional topographical and soils information may be required if unique site conditions. COMMERCIAL TENANT IMPROVEMENTS Two (2) sets of construction plans, which include: n Site plan • Location of tenant space • Existing and proposed parking • Landscape plan (if applicable, i.e.; change of use) Overall building plan • Tenant location • Use of adjacent (common wall) tenant • Overall dimensions of building or square footage n 'Floor plan of proposed tenant space • Tenant space plan with use of each room labelled. • Exit doors, egress patterns. • New walls, existing wall, and walls to be demolished. Completed building permit application (one for each structure or tenant) Assessor Account Number Construction details •.Cross sections showing wall construction and method of attachment for floor and ceiling. n Structural calculations stamped by a Washington State licensed engineer may be required if structural work is to be done (2 sets) : NOTE: If any utility work is to be done, submit separate utility permit application and plans.. : REROOF n Completed building permit application (one for each structure) Assessor Account Number Narrative describing existing roof, material being removed, and material being installed. NOTE: A certification letter is required prior to final inspection and sign- off of the permit. ANTENNA/SATELLITE DISHES I I II Completed building permit application Assessor Account Number Two (2) sets of plans, which include: Site Plan (showing: building and location of antenna/satellite dish) Details antenna/satellite dish and method of attachment Structural calculations stamped by a Washington State licensed engineer may be required RESIDENTIAL REMODELS Completed building permit application (one for each structure) n Assessor Account Number Two (2) sets of working drawings, which include: :• Site plan • Foundation plan • Floor plan Roof plan • Building elevations (all views) • • Building cross- section Structural framing plans NOTE: If any utility work is to be done provide utility permit application and plans must be submitted, REROOFS Completed building permit application (one for each structure) Assessor Account Number Narrative describing existing roof, material being removed, and material being installed. NOTE: A certification letter is required prior to final inspection and sign - off of the permit. CITY OF TUKWILA Address: 12400 EAST MARGINAL WY S Permit No: B96-0030 Tenant: GROUP HEALTH COOPERATIVE Status: ISSUED Type: 8-RACKS Applied: 01/31/1996 Parcel #: 734060-0480 Issued: 02/22/1996 ********************k*k**kk*Ak***k*-0,**kk**k**k***k****kkk4***44**kkwk444A, Permit Conditions: _ 1 No changes will be made_tothe:planS:Uniess.approved by the Architect or Engineer:.nandthe 7 All permits, inspeh and approved4fans shall be available at tneAtOb ite prior to the start o•Cancon- struction. T64e docUMentaretobe, maintathed andjavail- able until inspection approval is granted 3. All structural welding welders 40 tUBC - Sec. 4. All high-strength bolting shO,LWSpecial inspected Sec. 34(a)6). - • • 5. BoltsAnsta'1)ed concfr be ' inspected (UIEICIte06(a2). 6. \/ali ofPermit The issuiii,ke permit or aPpro , plans p specificationsand computations shall not be'„con- strued ttibe a,:perMtt:for, or an approval-of, any violation " of any of the provisions of the building code or of any - _ other or dinane of the iur is.iiction No pet pit prest.nuinotO give authority to violateOrcancel tne'..proVisions of'ythiS codeShalL-bevaltd. 7 When ,special inspection I. either required "eithethe owner, r r:_ at or engineer notify the, fukwila - , . Division of appointment of the ihspectiOn:agencies prior_to. the first building inspection. Copies of all special inspection reports shall be submitted-'toHihe BOlding . Division tria• timely manner. Reports snall'-contain projedt,HnaMe, permit number and type of inspection being performe 8. The special insp'ector shall subMit a final signedTeport, stating whether the work requiring special. inspection to the bet of the inspector knowledge; in confOrmanCe.: with approvedplans and specifications and the appli,c461e workmanship prOlslons of the UBC, 9. All constructiontoe done ),.1cOnforMance witIvapprOved plans and requiremOspf the Uniform Buildlng...Code (1994 Edition) as amended. q � ~_ ^ � ��»���~-^ 1@1/96 11:15 unt: 122^06 01p' In,t: XJp R���MIl numu=^^ 960 /[K N1300 _ Payment Method:- "" Notation: m ~-' .-'---'--------- RACK STORAGE PERMIT 0-RACKS 02/01/96 003O Type: it No: 896 Permit .o: 734060-0400 NA ' Y� S 12� 06 'ar, ` 12400 EAST ^~ ' \ Fees: ^ ' 'Site Address: Total 12y.0b � Total ALL pNty: , 00 122.06 Balance: o + ^ +++� This payment ++*+���*+�*��+*+*+* * ***a^*+++* Amount �^�+~+«+�+�*+** Description 71.25 Account Code BUILDING ` �ONK�S 46.31 0O0/322^10O PLAN CHECK - .NONK'ESuuH&� 4.50 0O0/345. STATE 8UILDlNu Su"^^^'' OOO/386.9O -'-.----.-_ 123 GENERA GENERA GENERA TOTAL CHECK CHANGE 2172A000 71"25 46.31 4.50 122.06 122.06 0.00 Projpv_t Type of inspectio : F1 A p 11 ( r�e ..J ss;� A Q P61144(... I` 7 / S Date called: Special instructions: Date wanted: _ _ 9 to a.m. Requester: RA1 1 , t 040 67 Phone N t 4 g - 1 4 1 g II �naav�rn :rw•.raa.......: • Vcouinv+m mfavalC y.aruP_VVRNIVEIRM '7OSW5g "'PC•Fk o`t994�4:. Approved per appliohip c die` Inspector: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 9818 MIT NO. 3-1 3670 Corrections required prior to approval. Date: Date: 4 S (0 $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No,: Project: 1 Type of inspe tion: Address: E, i' .. W Date called: S _ 9 , Special instructions 6,,aotA. a. ii--- Date wanted: S— /0 —gila p.m. Requester: M A Phone No.: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 ()94 0o3o PERMIT NO. (206) 431 -3670 Approved per applicable codes. Receipt No.: I 1 Corrections required prior to approval. COMMENTS: td it_t i tre $42.00 REINSPECTION EE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: Projec • so up N S ALT pe f inspection: b - �K oCCI LP't ddr ss: 2 400 r AAMINAI -Ntii ate called: - - 1 pecial :instructions: Date want ed p � 8'�ilo . . Requester: E1A+ 1 r`'ALL Phone No24 b , L l D ( g tY.T�ti3 .SN" ....... ` O'amP4.mi:Y.mrpsw INSPECTION RECORD Retain a copy with permit . -1 PERMIT NO. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. [Corrections required prior to approval. COMMENTS: Inspector: I f 141 LF'1 ALAC kS tJ,OA (1Y) S Y eAt,UirT- e — LaA-o ycK eNL1 Date: 5/ 819 (206) 431 - 3670 $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite•100. Call to schedule reinspection. Receipt No.: Date: Fire Department Thomas P. Keefe, Fire Chief Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: City of Tukwila TUICWILA FIRE DEPARTMENT FINAL APPROVAL FORM Project Name (5?/ / / ., ✓► �) Q Address / Z 5 r //.44A //.44A //U C I lJ � Retain current inspection schedule Needs shift inspection Permit No. JC' >9 i` c0 K - Approved without correction notice Approved with correction notice issued iLl 6 Authorized Signature Date FINALAPP.FRM T.F.D. Form F.P. 85 John W. Rants, Mayor Suite # Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) S7S - 4404 • Fax (206) 5754439 May 28, 1996 City of Tukwila Building Division 6200 Southcenter Boulevard Tukwila, WA 98188 Attn: Mr. Duane Griffin Re: Group Health - Tukwila Permi 12400 E Marginal Way Pharmacy • ousel Rack Tukwila, WA Gentlemen, This is to inform you that registered special inspections have been completed for this project as per our reports, copies of which have been sent you. To the best of our knowledge, all work inspected was either performed in accordance with, or corrected to conform to, the city approved drawings, or engineer approved changes. Special inspection was provided for: Expansion Anchor Installation We trust that this provides you with the information which you require. Should you have any questions give us a call. Sincerely, MAYES TESTING ENGINEERS, INC. 2 Michael S. Dolder, P.E. General Manager MSD:lmm 00496d.clo MAYES TESTING ENGINEERS, INC. RECEIVED cc: Brian Fyall - Lease Crutcher Lewis MY 1 1996 COMMUNITY DEVELOPMENT 917 - 134th St. S.W., Suite A -1 • Everett, WA 98204 • (206) 742 -9360 • FAX (206) 745 -1737 May 10, 1996 MAYES City of Tukwila Building Division 6200 Southcenter Boulevard Tukwila, WA 98188 Attn: Mr. Duane Griffin Re: Group Health - Tukwila 12400 E Marginal Way Tukwila, WA Gentlemen, Special inspection was provided for: Sincerely, Structural Steel Welding Expansion Anchor Installation MAYES TESTING ENGINEERS, INC. Michael S. Dolder General Manager MSD:lmm 00496c.cio cc: Brian Fyall - Lease Crutcher Lewis mmansatrirmalw SSran arrvwrva.xcaka.ermas sat.wwaa+raotarnrrnOxfterwerva TESTING ENGINEERS, INC. Permit This is to inform you that registered special inspections have been completed for this project as per our reports, copies of which have been sent you. To the best of our knowledge, all work inspected was either performed in accordance with, or corrected to conform to, the city approved drawings, or engineer approved changes. We trust that this provides you with the information which you require. Should you have any questions give us a call. RECEIVED MAY 1 4 1996 COMMUNITY DEVELOPMENT 917 - 134th St. S.W., Suite A -1 • Everett, WA 98204 • (206) 742 -9360 • FAX (206) 745 -1737 r............,cua.v:.:wiar.cv:c Is.:7.tr.on:maa• taara:+- r Seattle Bothell Tacoma Sumner Peninsula Portland One Lab. One Consultant. Pacific( Testing Laboratories One Solution. Sincerely, Corporate Offices 3257 16th Avenue West Seattle, WA 98119 -170 U.S.A. Tel: (206) 282 -0666 Fax: 1206) 282 -0710 : ;ki.a•:+' .�1�&;: -a eCi:YYr+1'A.i : +X,.".4:it RTYI cY+ a! KseAK# e!r Srx! tz :;¢e."flnsh;cr«'re.AYZAIM«. &rzr:e.Sr MIrK a?.•rr MNarYrm tkar m»waeC:rrc tw.ra+ wwa<wAu< ,.. May 6, 1996 Certificate No. 9604 -0050 Mr. Duane Griffin CITY OF TUKWILA BUILDING DEPARTMENT 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 Subject: Project Name Group Health Project Address ?400.Marginal Way South Permit No. B96-0030 , We have completed the requestee special on the subject project. Our final report, dated May 1, 1996, is numbered FR 6556. WORK REQUIRED WORK INSPECTED Expansion anchor installation Expansion anchor installation To the best of our knowledge, all work inspected conformed to approved plans, specifications, UBC, and related codes, and /or verbal or written instructions from the Engineer of Record. Reviewed by: William B. Throne, Manager, Seattle Inspection JCF /kc es C. Fre ins, '. ., Presitent cc: Mr. Richard Chaffee NORTHERN STEEL 22257 West Valley Hwy. Kent, WA 98032 (23 MAY 0 9 1c COMMU rs'VELO ,...: A PRINTED ON RECYCLED PAPER 05/07/96 12:25 FAX 206 248 8700 HOLIDAY PARKS J HOLADAY- PARKS, INC. COMPANY: LCL ATTENTION: Brian Fail FACSIMILE PHONE NO: 901 -6917 JOB NAMES: Group Health - ROC NO. OF PAGES (INCL. COVER): 3 REMARKS: Brian, Attached is a copy of our fax to Lt. Mosley dated 1/23/96. We asked him to approve the dust collection system designs. The copy of our phone log verifies that Lt. Mosley called Dan Connell on 1/30/96 and verbally gave us his approval. FROM: Randy Ritter CC: Troy B. Street Address: 4800 South 134th Place Seethe, WA 98168 -0218 NOTE: IF YOU DO NOT RECEIVE ALL PAGES, PLEASE CALL IMMEDIATELY. Mailing Address: P.O. Box 69208 (206)248.9700 Seattle, WA 98108.9208 FAX 248.8700 WA: HOLADP137INO tit 001 FACSIMILE COVER SHEET C) DATE: May 7, 1996 JOB NOIS): 43015 INITIALS: Rfa Alaska, Division: 1820 Merike (907) 452-7151 Fairbanks, AK 99709 FAX 452.3800 AK: AA061 a 05/07/96 12:25 FAX 206 248 8700 • HOLADAY- PARKS, INC COMPANY: Tukwila Fire Department ATTENTION: Lt. Jim Mosley FACSIMILE PHONE NO: 575 -4439 NO. OF PAGES (INCL. COVER): 4 REMARKS: FROM: Dan Connell, Project Engineer, 248.8717 CC: Troy Bloedel Street Address: 4600 South 134th Placa Seattle, WA 98188 -6218 Matag Address: P.O. Box 69208 Seattle, WA 98168 -9208 ROI-ADM' PARKS JOB NAMES: Group Health Riverton Operation Center Lt. Mosley, We are in the process of designing two dust collection systems for the Group Health Riverton Operation Center, (ROC), renovation. Our goal in writing this letter is to diffuse any potential problems that might arise through local Interpretations of the NFPA or Fire code. As we have discussed in a previous phone conversation, we will have two small dust collection units that each have approximately 400 CFM. The first dust collector ROCDC001, will be located in a dedicated perimeter room, vented to the outside, and have explosion doors with sheet metal vents directly vented to the outside. The collector will be used to collect small (5 micron) particles of plastic from a production lens grinder. The second dust collector, ROCDC002, is located on the roof of the two story building. It will have explosion doors, with no recycling of air back into the building. The collector serves the pharmacy area where it will collect pill dust from two small packaging rooms. For both of the systems, we will use SMACNA 8" to 11" negative pressure class ductwork design. Enclosed is a detail of ROCDC001 located inside the building on a perimeter wall, and ROCDC002, located on the root. Please look over the design and let us know If the design is appropriate to the application. Thank -you for your cooperation. (206) 248 -9700 FAX 248-870C WA: HOLADP1374H0 FACSIMILE COVER SHEET DATE: Jan. 23. 1998 JOB NO(S): 43015 INITIALS: DC ( OF a v ,6 4 > �``S r ' 4(r (9. �� C.:.v Alaska Division: 1820 Marika Fairbanks, AK 99709 (907) 452 -7151 FAX 452 -3800 AK:AA0518 NOTES: 05/07/96 12:26 FAX 206 248 8700 DAY. R KL o TALKED WITH 4 Iftt dec•tok su 1ew, 1 0,04. Dc. n 0J') 70131M42Y o C[hYJarj ACTION OR FOLLOW UP NECESSARY H.P FORM 0401 (3/53) WA Reg. Na NO•LA-01x1379NO AK Aeq. No M0518 OF T k e. I r'i k a. pi Me 'l • , HOLIDAY PARKS DATE. is / *1),. s.-1 („ Q//`c 74)4.. ••* l P V« O O ' ' \ ~ r' SUBJECT &H JOB NAME l. / - � H Roc- PRODUCT HP JOB it CUSTOMER ORDER /JOB #: TELEPHONE CONVERSATION RECORD J003 TIME• 2 QUOTATION MADE PARTY CALLED ME I PLACED CALL PHONE NO 430/5 545- 1-0y07- •G -oo3D c ( +) Ts 4-3 z- X x CITY OF TUKWILA RACK STORAGE DIMENSIONS LINEAR FEET X HEIGHT = TOTAL V3 , (j ' 40 ' 4 :; X (o ' _ ci- o o C k \) 'z4- r ' X ( a ' = "z `t' 0 (3 (9 ' - Z o 1 X P' = (1/206 U 34--. o.2.- x zo/ _ GRAND TOTAL = RECEIVED CITY OF TUKWILA JAN 311996 PERMIT CENTER 71�1Yw�':2NiWG3tVwtGw.n ,ra..�r..... .• Structural Calculations for Group Health Cooperative Riverton Operations Center Warehouse Rack Storage But RECEIVED CITY OF TUKWILA JAN 3 1 1996 PERMIT CENTER A tit t u&•t oral Engineering l'urporatut 1 - 30 - 9e project dale D N Swenson Say Faget design prof. no. csvelZ sheet 1925 Post Alley • Seattle. WA 98101 • Phone (200) 443.6212 • Fax (206) 443 -4870 CRITERIA WIRE SHELVING WIRE SHELVING BRACE PALLET SHELVING OVERTURNING PALLET SHELVING TRANSVERSE FRAMES BEAM INSPECTION BRACED FRAME SECTIONS PALLET SHELVING LONGITUDINAL ANSLYSIS BRACE POST SPREADER POST STABILITY ANALYSIS BRACE BOLT ANCHORS NORTHERN STEEL PALLET RACKS TRANSVERSE DIRECTION BRACED FRAMES LONGITUDINAL DIRECTION MOMENT BRACING BRACING SLAB AND SOIL TYPE A TYPE B SPANS BEAM STATIC COLUMNS BEAM SECTION PROPERTIES PREPARED BY P.S. ring ey DRAWING NO. R -1 DATE 14 SEP.'93 REVISION NO. DATE BY MODEL t in = C C Ix in S in rx in I 1n Sy in r in AREA 1n L8020 .075 2 .75 .2928 .274 .716 .6033 .4133 1.031 .5718 1.8030 .075 3 .75 .7604 .4659 1.026 .8786 .6054 1.103 .7218 LB035 .075 3.5 .75 1.1854 .6313 1.223 .9475 .6712 1.093 .7922 LBC30 .075 3 .75 1.3689 .8817 .184 .9403 .6099 .9820 .975 L9C35 .075 3.5 .75 1.951 1.0473 1.363 .9705 .6159 .9614 1.050 LBC 40 .075 4 1.5 2.6631 1.2769 1.538 1.105 .7096 .9921 1.125 L8C 45 .075 4.5 1.5 3.5073 1.5033 1.709 1.2449 .8025 1.018 1.200 LBC50 .075 5 1.5 4.6437 1.7655 1.908 1.3902 .9029 1.044 1.275 LBC55 .075 5.5 1.5 5.7951 2.0453 2.071 1.5269 .9975 1.238 1.350 LBC55A .105 5.5 1.5 7.7919 2.7571 2.038 2.0719 1.3498 1.051 , 1.876 LBC60A .105 6 1.5 9.587 3.1421 2.192 2.1979 1.4517 1.049 1.995 L8F356 .060 3.5 1.5 1.2039 .6277 1.274 .7576 .5097 1.011 .7414 LBF354 .075 3.5 1.5 1.4739 .7699 1.267 .9284 .6242 1.006 .9181 L8F404 .075 4 1.5 2.0512 .9481 1.437 1.0635 .7190 1.035 .9931 L8F454 .075 4.5 1.5 2.7526 1.141 1.605 1.1984 .8143 1.059 1.0681 L8F453 .090 4.5 1.5 3.2119 1.333 1.598 1.3985 .9497 1.054 1.2578 'r COLUMN SECTION PROPERTIES PREPARED BY P.s.ringey DRAWING NO. R-2 DATE 16 JAN.'92 REVISION NO. DATE BY A 15APR'93 PST MODEL t In H In B In X In I in S In r In Iy In Sy In ry In AREA In LM 15 .075 3 1.625 .689 .582 .388 1.156 .205 .219 .686 .411 LM20 .075 3 3 1.435 1.023 .682 1.263 .872 .557 1.165 .618 LM30 .105 3 3 1.45 1.373 .915 1.249 1.164 .752 1.15 .859 LM20/15 ' ° 7 0 7 5 3 4.625 2.607 1.78 1.187 1.231 2.577 .988 1.481 1.143 LM20 /20 ' 3 6 2.714 2.222 1.481 1.268 4.701 1.431 1.845 1.349 LM30/ 15 ` 1 ° 0 5 3 4.625 2.789 2.126 1.417 1.23 3.052 1.094 1.473 1.384 LM30/20 ' 3 6 2.951 2.568 1.712 1.262 5.45 1.788 1.838 1.590 LM30/30 ' I 0 05 3 6 2.707 2.98 1.986 1.256 6.387 1.94 1.839 1.875 Lid PRIMARY COLUMN PUNCHED .75 BACK-UP COLUMN UNPUNCHED B y X 6 GAGE T in X in I. in S in r in 1y in Sy in ry in AREA in 2 16 .060 .4169 .0893 .1190 .6234 .0379 .0456 .4056 .2297 14 .075 .4261 .1081 .1440 .6169 .0464 .0564 .4043 .2839 12 .105 .4405 .1418 .1890 .6041 .0621 .0767 .3999 .3885 10 .125 .4551 .1706 .2275 .5914 .0764 .0960 .3956 .4878 BRACING SECTION PROPERTIES PREPARED BY P. TINGEY DATE 10MAY91 7 NO. DRAWING NO. R -a REVISION DATE BY 10 9 In °dZ 8 oa 7 ao 6 x a cn 5 W G dN 4 0 o 3 a 2 1 0 20 H =1 1/2 } Y t - T X I+- B= 1 1/4 ■ ■11711111.1 1111111111111111111111111111111111111111111111111111111111 MR I MI 111111111111111111111111111111111111111111111111111111111 :2\ =���i� 10 G 1111111111111111n11111111111111111111111111111111111 ■■ Rate ■RRR .mmo RRRRRMRMRUUMU■ ■u■ 14 G \��� \������������■ RIM 'rRR ►14R►,1RRRRRRRRRRR ■11M■ ,RRRE ∎1101RMMRRRRRRR ■ RRRmmm \rminum om5 ■MnI RR111601UR; :11RR:1■ 30 40 50 60 LENGTH IN INCHES 70 13.3 14.6 10.6 9.31 7.98 6.65 5.32 3.99 2.66 1.33 0 80 0 -.1 0 J Z -o W o m� a O z Q cn Q � N W - In 7 STANDARD 3-PIN LIMIT BRACKET MOMENT CAPACITY PIN MATERIAL COLUMN MATERIAL 4-PIN LIMIT BRACKET ALLOW MOMENT CAP Dear Sir: City of Tukwila Fire Department Fire Department Review Control #B96 -0030 (510) • February 7, 1996 Re: Group Health - 12400 East Marginal Way South The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. Smoke venting, curtain boards and building access required by Table 81 -A of the 1994 edition of the Uniform Fire Code, shall be provided and installed per section 8102.7 and Table 81 -B of the 1994 edition of the Uniform Fire Code. 2. In double row racks with heights of storage up to and including 25', an average nominal 6" transverse flue space between loads or at rack uprights shall be maintained. (NFPA 231C 4 -3.1) Maintain minimum 6" longitudinal flue space between back to back racks. (NFPA 231C) John W. Rants, Mayor Thomas P. Keefe, The Chief 3. Where storage height exceeds 15 feet and ceiling sprinklers only are installed, fire protection by one of the following methods is required for steel building columns located within racks: (a) one -hour fire proofing, (b) sidewall sprinkler at the 15 foot elevation of the column, (c) ceiling sprinkler density minimums as determined by the Tukwila Fire Prevention Bureau. (NFPA 231C, 3 -2.3) All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 5754439 Page number 2 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recognized by The City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1742) 4. In groups A, B, E, F, I, M, R and S occupancies, quantities of flammable and combustible liquids used for demonstration, treatment and laboratory work exceeding 10 gallons shall be stored in liquid storage cabinets. Quantities not exceeding 10 gallons shall be in approved locations. (UFC 7902.5.8) The combined quantity of class I and II liquids in a cabinet shall not exceed 60 gallons, and the total quantities of all liquids shall not exceed 120 gallons. (UFC 7902.5.9.2) 5. The total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 3000 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 10B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (NFPA 10, 3 -1.1) Extinguishers shall be installed on the hangers or in the brackets supplied, mounted in cabinets, or set on shelves (NFPA 10, 1 -6.9), and shall be installed so that the top of the extinguisher is not more than 5 feet above the floor. (NFPA 10, 1 -6.9) Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be identified with a sign stating, "Fire Extinguisher ", with an arrow pointing to the unit. (NFPA 10, 1 -6.3) (UFC Standard 10 -1) Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely John W. Rants, Mayor Thomas P. Keefe, Fire Chief Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone (206) 575 -4404 • Fax (206) 5754439 City of Tukwila Fire Department Thomas P. Keefe, The Chief Page number 3 attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. (NFPA 10, 4 -3, 4 -4 and 4 -4.3) Every six years, dry chemical and halon type fire extinguishers shall be emptied and subjected to the, applicable recharge procedures. (NFPA 10, 4 -4.1) If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10A -4 -4) Maintain fire extinguisher coverage throughout. 6. No point in a sprinklered building may be more than 200 feet from an exit, measured along the path of travel. (UBC 1003.4) Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 1207.3) Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. 7. Maintain sprinkler coverage per N.F.P.A. 13. Addition /relocation of walls, closets or partitions may require relocating and /or adding sprinkler heads. All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the John W Rants, Mayor Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone.. (206) 575 -4404 • Fax (206) 57$4439 City of Tukwila Flre Department Page number 4 W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recognized by The City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1742), Sprinkler protection shall be extended to all areas where required, including all enclosed areas, below obstructions and under overhangs greater than four feet wide. (NFPA 13 -4- 4.1.3.2.1) Thomas P. Keefe, Fire Chief 8. Maintain automatic fire detector coverage per N.F.P.A. 72. Addition /relocation of walls, closets or partitions may require relocating and /or adding automatic fire detectors. All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1742) (UFC 1001.3) 9. All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. John W. Rants, Mayor Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 5754439 Yours truly, L City of Tukwila Fire Department Thomas P. Keefe, Fire Chief Page number 5 cc: TFD file ncd • The Tukwila Fire Prevention Bureau John W. Rants, Mayor Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 5754439 •'. . ".; Ccf?Ea:sTri dritallyigEF ` :. .:;r':;'• • ' •= i6 �;.i '`n:l' r ;s. ' ' 1, :�.L•EA L;:1 4NEr ; 1f.9 . ':,;r;• = . =FF;= F''t'.TS: !•F b ?1.7RS r7 DETACH TO DISPLAY CERTIFICATE M! M• r! �9��+• Y.r�wiv ✓ %�NiNiNVNINiMiN /iwnivy/ / �rivryM!: NVN�v/ ir.ifNn!vlFi�nniiwJVwNf�9!<M!�v DEPARTMENT OF LABOR AND INDUSTRIES THIS CERTIFIES THAT THE PERSON NAMED HEREON IS REGISTERED AS PROVIDED BY LAW AS A • Y y' si� • 7. STATE OF WASHINGTON t_ DETACH TO DISPLAY CERTIFICATE_i This is to certify that this is a true copy of the current Washington State contractor's license for LEASE CR[TI'CHER LEWIS. , 199 6. Notary Public in and for th /�f Washington, residing at My commission expires /- ,2-- - F625.152-000 (342) t% 5 ?W ABBREVIATIONS A NBBJ 1)1 South Jackson Street Seattle. Washington 98104 (206) 223 -5555 Fax 1206) 621 -2300 Groan Hearth Cooperative of Puget Sound Fol_J :SG ADDRESS 8 01,.: :it07 3. LAND USE 1CNE 4. 3U;L0I96 CODE 5. 1, U: :HG'% TYPE 6. CDC'. ,Y CROP n 7,R:A GRAPHICS D am. re,T0or co- if BA7.1 TAB CODE INFORMATION 10161 \5 ChAnnel Per Dian n NIverc sense Fee. unm 12490 E. MARGINAL WAY S Seeitte, Washington 98124 CC, 01 i4471;6 Sew COsOlOWCSON 0/,70 SeORAGE ONLY FAOo3o North Amor. Riverton Operations Center PHASE III CM era Synbas ARGIL lAGN_ Number IdentilIcalIGA AecteWelventites twow 5 et W r OAS 70) Sneer water rrA7.44) Z6te llm e cl0044) Pewit ;nea ° ix e ,end 740 _ — ¢ 5 _e MAS 61— rr «I Nan,6er Revision I415m4 0:) u. - I UGH1 I7, 4447 499 U9C w/ WA. STALE AMEN50ENTS TYPE 5-17 SP9l,'/ 0 6 TYPE II -N S7491'EREO D::PAF 4191 AREA OCCUPANCY PHARMACY STORAGE 7,560 SF F I 'NARJI01 21,830 Se 1 2 20,450 SF WAREHOUSE RACK STORAGE DRAWING INDEX 18 R OHITE CT11R Al O Ir COVER YEN AWN r Sl ALTAR PLAN (r /a') AR WY PHARMACY PPE PLAN (1/e) AIRS/ wAREHMSE rrE PLAN (Vol) STRUCTURAL, S].SW PHARMACY PLAN / SEISMIC BRACING SIPA rWePtena PUN / SEISMIC PLAN SS.OM SEISMIC RRAONG [EIALS SSIw CAPCUSIL PLAN SS PW CAROUSEL PLAN w A 0:0777 RACK PLAN SS ', HAREMO. RAG / Kate DMus LEGAL DESCRIPTION That portion of tracts 21, 22, 31, and 32, Riverside to lerurban Tracts according la the Plat recorded n Volume 10, of Plots page 74 in ,t;ng County, Washington, more portcu only described as follows'. Beginning at a point on the westerly margin of primary stale Highway No. I, Foster interchange lo South .118th Street, as condemned under Superior Court Cause No. 646846, that bears south 0433'59" east 165.03 feet 00407] (tom the paint of curvature of the west margin highway engineers' station 76005.30 said point also being the southeast corner of that tartan Iraq of land as desdbe4 in op)on agreement carded under A4d'tors F.e No. 7506090402' thence south 043350 east along said margin 615.17 (eel to c point lying 113 feel westerly of and opposite engineers' station 68025; thence south 5819'00" west cjong sold highway morain 23032 feel, thence south 1809'20" east ateng said highwoy margin 36.80 feel to the south lice of Iraq 32 of the Riverside Interurban Tracts; thence north 89I/'24' west 476.97 feel along the south line of tracts OT and 32 to the easterly margin of Cost Marginal Woy as established by warranty decd found n King County records, /ing Country Recorders No. 7412030465; thence north 1838'24" west 442.48 feet along said siedy margin; thence 70114 1254'24" west 443.48 feet along said easterly margin; (hence north 1027'14' 0est 333.78 feel song said easterly margin to the th I corner of option ogreernant recorded undo A d1 No. 506090402; hence south 8917'24" t prettliel to the th line of tracts 31. and 32 Riverside l b Tracts, a 0870000 of 774,30 feet to the point of beginning. OAT REaSI 1 SITE PLAN SCALP: 1" o 100 CIRCULATION PROPOSED NEW WORK 1/29/96 476.97 774.30 Bmryldnd wsyds Permit Submittal PROJECT TEAM Client: Group Health Cooperat ive 521 Wall Street Beadle, WA 98121 206/448 -2355 Pro), Mgr: Jae Neuens072070er Architect: 6092 111 South Jackson Street Seattle, WA 98104 206/223 -5555 Project Mgr: Brian Berg Structural: Swenson Soy Fogel 1921 Post Alley Seattle, WA 98101 206/443 -6212 Project Mgr: Don Soy General Contractor: Lease Crulcher Lewis 107 Spring Street Seattle, WA 98101 206/622 -0500 Project Mgr: Mike 2000:Wand LOCATION MAP ID ID Y.� C O V E R S H E E T Engineer!ng Management Landis k Cyr Powers 43020 NE 201, re Bellevue, VIA 98005 Stet 206/455 -3/00 Project Mgr: Joy Masson Elecrical: Huntl P0s0oe Inc, Canyon Park Business Center 22025 tam Avenue 5E, Ste. 4407 Bothell, WA 98024 -4406 6/485 - Pr Mgr. 0900 Roger Huntley Mechonieal: H01ad0y Parks, Inc. 7 P. 4600 0. BCx 69208 5001110, 5. WA 4341 98168 -Place 9208 2 roject -3344 Project Mgr: E. 7106 8104081 SPECIAL INSPECTIONS BY AN APPROVED TESTING LABI'REQUIRED AND ADMINISTERED AS DESCRIBED IN- U.B.C. SECTION 1701. 1 ) 0 1 ) ) ) ) ) ) I 1 7 ) ) ) ) ) ) I I 11 C I II t 4I 11 1 U�\�\ fi rVAV \� (5 / / / / / / / / / / / / / / /// 1 _///////////////////1_1 aMMA E ARKw0 / / / / / / / / / / / / / / //L J \n = ogle pence Scde NIS Ap eond By WS/ 04 ni.t. 40789.03 oayd BEB _ OrereDDS _ nn_ 1/29196 EWIING PARKING _ �Ppp( FEB 1H OVo P& A f O S E nM , .L JAN 3)1996 PEWIT MM. Permit Submittal AO.OW NBBJ 111 South Jackson Street Seattle. Washington 98104 (2061 223 -5555 Fax 1206) 621 -2300 e x i t 13q6---0030 e x i t Group Health Cooperative WAREHOUSE RACK STORAGE of Puget Sound Riverton Operations Center PHASE III TYPE 5 -N CONSTRUCTION TWO STORY TYPE 2 CONSTRUCTION ONE STORY e x i t Nrtbee Date 1/29/96 e x i t Legend j A d Permit Submittal s O R t i c u 1 i i i a� ® i t 161 ' 1,02e L AP► Warehouse S -2 OCCUPANCY 21,890 SF Unoccup° led Pharmacy S t o r a g e F-1 OCCUPANCY 7,560 SF Data Center ONE HOUR CORRIDOR (SHOWN HATCHED) i ?I DEPARTMENT EXTENTS 0 FIRST FLOOR EXITING PLAN SCALE: , = 20 ._.,....,. n f FIRST FLOOR EXITING PLAN t, 11 Unoccupied e` d I' - 20' 4,“419d., S HP kb linker 40789.03 Dnged BPS Dwn 129 ceded SOP Date 1/29/96 JAN 3 11996 PERM crx,�L Permit Submittal A1.1W ain a < O • LL a NBBJ lit South Jackson Street Seattle. Washington 98104 12061 223 -5555 Fax 12061 621 -2300 Group Health Cooperative of Puget Sound WAREHOUSE RACK STORAGE Riverton Operations Center PHASE III 0 PHARMACY WAREHOUSE PLAN SCALE: I /e" - 1L-C DO By Dxx4I+n d wem+w 1/29/96 Permit Submittal PHARMACY STORAGE FURNISHINGS, FIXTURES and EQUIPMENT PLAN JAN 3 t 1996 PERM CENTER 1/8" egr4.+.19y SOP 05 Nd% 40789.03 0,40:1 0E8 uw.n JG0 0.4d SOP D. X29 96 Permit Submittal A3.5W re 79 NBBJ 111 South Jackson Street Seattle. Washington 98104 12061 223 -5555 Fax 12061 621 -2300 fi k , Groap Health Cooperative of Puget Sound 57 UP ELEV 100E3 )I T KLAM ROOA F108 ) OM E ( F10 1 STORAGE ( F109 5 GOOF ( F105 EQUIP CHARGE J ( F107 ) DISPATCH ( F103 ) BREAK DOWN ( F102 Di r Case; • 0 T NIT NOT IN PROJECT T CORR. ( 10007 ) NAIL RDDN (7 TALL) OT IN NAOS T SHELL Jr 7L Ll r . IN lnn5IFII 1 1E±117 7F CAAWSEI (5EE SOlw;M'0 SU Imo I L❑ JLPLJL L L ,C ❑❑L) t■ MI JL1L 1 1 'V If - TACI fin• 17171Clf 7L 1 J1 1I iL 717(7 I0L CAROUSEL (NEE SASS AND 55.077 u J 0 Si J C L1 NI NI J O CAROM (06 55.15 AND SLOW) �C]❑L Li❑❑L❑❑LHILJ❑L7 J II - 1f]L PALLET RACKS ( 55.30 AND 55,4W1 inrspj / A/47 --� PAO£T RACKS( E SEM APO 5540) - �/// PPILET RAIXS ( E 55JW AND 5 W) - PA11£i RAIXS ('E 55.30 GNO 554Yff PAgET AACNS (RE 55.30 {NO SSA) PS RACK (SEE 55.30 tiNO 1, 1./ NWT RAp{5 (SEE S5STI AND 4W) PALLET PACK (SE E 55.30 ,WD 05.44) 1 /i LEECH 100403 /TY EM CAR WOMEN'S ( F118 ) MEN'S ( F118 CORR. (mom LOADING D. (0 Riverton Operations Center PHASE HI ) MIS P. IS NOT A REa1114 EIRE EMIT 5 WAREHOUSE RACK STORAGE 0 WAREHOUSE PLAN SCALE. 1 /3 = l -0 Dole BY Denylm d R5A.) 1/29/96 Perrot Submittal Seel IAD W A R E H O U S E RACK STORAGE PAIR RAMS 0500170 OAR 0 UMOa PAST JAN 3 11996 PERMIT CENTER Scab 1/8 " =1' -0• wed By 008 86 NAM( 40789.03 DeMmd 868 DT MI HEH Cka.d OOP We 1/29/96 Permit Submittal A3.8W GENERAL STRUCTURAL NOTES (The following apply unless shown otherwise on the plans) CRITERIA I. ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS, SPECIFICATIONS, AND THE UNIFORM BUILDING CODE (1994 EDITION). 2. DESIGN LOADING CRITERIA EARTHQUAKE ZONE 3, Fp = 0.225 Vp 3. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL DRAWINGS FOR BIDDING AND CONSTRUCTION. CONTRACTOR SHALL VERIFY DIMENSIONS AND CONDITIONS FOR COMPATIBILITY AND SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. 4. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS, MEMBER SIZES, AND CONDITIONS PRIOR TO COMMENCING ANY WORK. ALL DIMENSIONS OF EXISTING CONSTRUCTION SHOWN ON THE DRAWINGS ARE INTENDED AS GUIDELINES ONLY AND MUST BE VERIFIED. 5. CONTRACTOR SHALL PROVIDE TEMPORARY BRACING FOR THE STRUCTURE AND STRUCTURAL COMPONENTS UNTIL ALL FINAL CONNECTIONS HAVE BEEN COfLETED IN ACCORDANCE WITH THE PLANS. 6. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED TO PERFORM HIS WORN. THE STRUCTURAL ENGINEER HAS NO OVERALL SUPERVISORY AUTIORITY OR ACTUAL AND/OR DIRECT RESPONSIBILITY FOR THE SPECIFIC WORKING CONDITIONS AT THE SITE AND/OR FOR ANY HAZARDS RESULTING FROM THE ACTIONS O ANY TRADE CONTRACTOR. THE STRUCTURAL ENGINEER HAS NO DUTY TO INSPECT, SUPERVISE. NOTE. CORRECT, OR REPORT ANY HEALTH OR SAFETY DEFICIENCIES OF THE OWNER. CONTRACTORS, OR OTHER ENTITIES OR PERSONS AT THE PROJECT SITE. 7. CONTRACTOR- INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT AND STRUCTURAL ENGINEER FOR APPROVAL PRIOR TO FABRICATION OP CONSTRUCTION. CHANGES INDIAN ON SHOP DRAWINGS ONLY WILL NOT SATISFY THIS REQUIREMENT. 8. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE O SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED, SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT AND THE STRUCTURAL ENGINFER. 9. ALL STRUCTURAL SYSTEMS WHICH ARE TO BE COMPOSED OF COMPONENTS TO BE FIELD ERECTED SHALL BE SUPERVISED BY THE SUPPLIER DURING K4NUFACTURING, DELIVERY, HANDLING, STORAGE AND ERECTION IN ACCORDANCE WITH INSTRUCTIONS PREPARED BY THE SUPPLIER. 10. SHOP DRAWINGS FOR STRUCTURAL STEEL SHALL BE SUBMITTED TO THE ARCHITECT AND STRUCTURAL ENGINEER FOR REVIEW PRIOR TO FABRICATION OF THESE ITEMS. APPROVED SETS OF ALL SHOP DRAWINGS SHALL ALSO BE SUBMITTED TO THE BUILDING DEPARTMENT, II. SHOP DRAWING REVIEW' DIMENSIONS AND QUANTITIES ARE NOT REVIEWED BY THE ENGINEER OF RECORD, THEREFORE MUST BE VERIFIED BY THE CONTRACTOR. CONTRACTOR SHALL REVIEW AND STAMP DRAWINGS PRIOR TO REVIEW BY ENGINEER OF RECORD. CONTRACTOR SHALL REVIEW DRAWINGS FOR CONFORMANCE WITH THE MEANS, METHODS, TECHNIQUES, SEQUENCES AND OPERATIONS OF CONSTRUCTION, AND ALL SAFETY PRECAUTIONS AND PROGRAMS INCIDENTAL THERETO. SUBMITTALS SHALL INCLUDE A REPRODUCIBLE AND ONE COPY! REPRODUCIBLE WILL BE MARKED AND RETURNED. SHOP DRAWING SUBMITTALS PROCESSED BY THE ENGINEER ARE NOT CHANGE ORDERS. THE PURPOSE OF SHOP DRAWING SUBMITTALS BY THE CONTRACTOR IS TO DEMONSTRATE TO THE ENGINEER THAT THE CONTRACTOR UNDERSTANDS THE DESIGN CONCEPT, BY INDICATING WHICH MATERIAL IS INTENDED TO BE FURNISHED AND INSTALLED AND BY DETAILING THE INTENDED FABRICATION AND INSTALLATION METHODS. IF DEVIATIONS, DISCREPANCIES, OR CONFLICTS BETWEEN SHOP ➢RAVING SUBMITTALS AND THE CONTRACT DOCUMENTS ARE DISCOVERED EITHER PRIOR TO OR AFTER SHOP DRAWING SUBMITTALS ARE PROCESSED BY THE ENGINEER, THE DESIGN DRAWINGS AND SPECIFICATIONS SHALL CONTROL AND SHALL BE FOLLOWED. SHOP DRAWINGS OF DESIGN BUILD COMPONENTS INCLUDING STAIRS AND EXTERIOR CLADDING SHALL INCLUDE THE DESIGNING PROFESSIONAL ENGINEER'S STAMP, STATE OF WASHINGTON AND SHALL BE APPROVED BY THE COMPONENT DESIGNER PRIOR TN CURSORY REVIEW BY THE ENGINEER OF RECORD FOR LOADS IMPOSED ON THE BASIC STRUCTURE. THE COMPONENT DESIGNER IS RESPONSIBLE FOR CODE CONFORMANCE AND ALL NECESSARY CONNECTIONS NET SPECIFICALLY CALLED OUT ON ARCHITECTURAL OR STRUCTURAL DRAWINGS. SHOP DRAWINGS SHALL INDICATE MAGNITUDE AND DIRECTION OF ALL LOADS IMPOSED ON BASIC STRUCTURE, DESIGN CALCULATIONS SHALL BE MADE AVAILABLE UPON REQUEST, 12. SPECIAL INSPECTION OF THE FOLLOWING TYPES OF CONSTRUCTION SHALL BE PROVIDED IN ACCORDANCE WITH SECTIONS 108 AND 1701 OF THE UNIFORM BUILDING CODE AND THE PROJECT SPECIFICATIONS BY A QUALIFIED TESTING AGENCY DESIGNATED BY THE ARCHITECT, AND RETAINED BY THE BUILDING OWNER. THE ARCHITECT, STRUCTURAL ENGINEER, AND BUILDING DEPARTMENT SHALL BE FURNISHED WITH COPIES OF ALL IN- SPECTION AND TEST RESULTS. NBBJ STRUCTURAL STEEL FABRICATION AND ERECTION (INCLUDING FIELD WELDING AND HIGH-STRENGTH FIELD BOLTING) EXPANSION BOLTS AND THREADED EXPANSION INSERTS EPDXY GROUTED INSTALLATIONS 10 South Jackson Street Snaffle. Washington 98104 (206) 223 -5555 FOR (206) 621 -2300 Swenson Say Fagot A s6riaaww.4 , loydrwnnnn Corpora.. A (2P4) a 0 0, izaa 400.040 ANCHORAGE 13. EXPANSION BOLTS INTO CONCRETE SHALL RE 'TRU -BOLT' WEDGE ANCHORS. EXPANSION BOLTS INTO GROUTED MASONRY UNITS SHALL BE 'OYNA -BOLT' SLEEVE ANCHORS. THREADED EXPANSION INSERTS INTO CONCRETE OR GROUTED MASONRY UNITS SHALL BE NON -DRILL ANCHORS, AS MANUFACTURED BY ITN RAMSET /RED HEAD INSTALLED IN STRICT ACCORDANCE WITH I.C.B.O. REPORT NO. 1372, INCLUDING MINIMUM EMBEDMENT REQUIREMENTS. BOLTS OR INSERTS INTO CONCRETE MASONRY OR BRICK MASONRY UNITS SHALL BE INTO FULLY GROUTED CELLS. SPECIAL INSPECTION IS REQUIRED FOR ALL EXPANSION BOLT AND INSERT INSTALLATION, 14. EPDXY-GROUTED ITEMS SPECIFIED ON THE DRAWINGS SHALL BE GROUTED WITH HS -200 SOLID BOND EPDXY BY ANCHOR -1T FASTENING SYSTEMS, ADHESIVES TECHNOLOGY CORPORATION. INSTALL IN STRICT ACCORDANCE WITH I.C.B.O. REPORT NO. 4398. SPECIAL INSPECTION OF INSTALLATION IS REQUIRED, STEEL 15, STRUCTURAL STEEL, INCLUDING PLATES AND ROLLED SHAPES, SHALL CONFORM TO ASTM A36, Fy = 36 KSI. STEEL PIPE SHALL CONFORM TO ASTM A -53, TYPE E OR S, GRADE B, Fy = 35 KS]. STRUCTURAL TUBING SHALL CONFORM TO ASTM A500, GRADE B, Fy = 46 KIT. ANCHOR BOLTS AND CONNECTION BOLTS SHALL CONFORM TO ASTM A307. 16. A..'. WELDING SHALL BE IN CONFORMANCE WITH A.I.S.C. AND A.W,S, STANDARDS AND SHALL BE PERFORMED BY W.A.B.O. CERTIFIED WELDERS USING E70 XX ELECTRODES, ONLY PREQ ALIFIED WELDS (AS DEFINED BY A.W.S.) SHALL BE USED, WELDING OF GRADE 60 REINFORCING BARS (IF REQUIRED) SHALL BE PERFORMED USING LOW HYDROGEN ELECTRODES. WELDING OF GRADE 40 REINFORCING BARS IF REQUIRED) SHALL BE PERFORMED USING E70XX ELECTRODES. WELDING WITHIN 4' OF COLD BENDS IN REINFORCING STEEL IS NUT PERMITTED. SEE REINFORCING NOTE FOR MATERIAL REQUIRENENTS OF WELDED BARS. t5910-0030 REFER 1/s5.0 FOR WALL ATTACHMENT' DETAILS FOR THIS SHELVING 8/S5.0 TYP. •iae ®s •■ � eataeae ®a ®ea'e® 7/S5 7/S5.0 8/S5.0 TYP. 7/S5 7 /55 -' /■ PHARMACY WAREHOUSE PARTIAL PLAN SCALE: I /8' = 'Group Health Cooperative of Puget Sound WAREHOUSE RACK STORAGE Riverton Operations Center PHASE III Sw. kgrookAly 4W WIN 5& I Raw JH Chided AN Ww (/27/54 REFER 1/S5.0 FOR WALL ATTACHMENT DETAILS FOR THIS SHELVING REFER 6/S5.0 FOR SEISMIC BRACING DETAILS FOR THIS SHELVING REFER 5/S5.0 FOR SEISMIC STRENGTHENING AND BASE ATTACHMENT DETAILS FOR THESE CAROUSELS REFER 8/S5.0 AND 7/S5.0 FOR SEISMIC STRENGTHENING AND BASE ATTACHMENT FOR THIS SHELVING REFER 1/S5.0 FOR WALL ATTACHMENT DETAILS FOR THIS SHELVING JAN 3 11996 Permit Submittal Nb NBBJ 111 South Jackson Street Seattle. Washington 98104 (206) 223 -5555 Fax 12061 621 -2300 Swenson Say fag €t A etmctant Engineer.. CemenEon 1 Post e 980 . MM. WA m 111.06).36.2 r, IMO 4434910 SCALE: 1/S• • r•o• REFER 5/S5.0 FOR SEISMIC STRENGTHENING AND BASE ATTACHMENT DETAILS FOR THESE CAROUSELS. REFER S5.IW & S5.2W FOR BASE MEMBER LOCATIONS AND FLOOR LOADS BY MFR. MINIM MONNE 11111•111111 MMMMM Mil•rata111lata11111M •ri•1111111 MUM Na RI SME NM MEN MINIM MINIM EMIR NI NEM MEIN MN la NI INMI ONE dI■alti■ ale!ei•1 IBM MI NI NM IN MMMMM'ti MI NM NUMIR IIII RI M t• NI• MN tip 15 -000 Group Health Cooperative of Puget Sound WAREHOUSE RACK STORAGE Riverton Operations Center PHASE III DESIGN AND DETAILING OF THESE PALLET RACKS BY OTHERS.-' WAREHOUSE PARTIAL PLAN Nnber so. k Dnettko of ba,. 1/29/96 Permit Submittal so. WAREHOUSE FURNISHINGS SEISMIC RRACINR so rm>.1 k a, kb eaea usmaun Duk,1 66). .re (Wad DI s. +NNo G1F td CA JAN 3 1 1996 MAW CWT. Permit Submittal S3.8W NOTE: BASE ATTACHMENT AND STRENGTHENING TO OCCUR AT EACH TRANSVERSE FRAME, TIP. E 1 /iee 13 S5.0 13 55.0 EXIST. STEEL FRAMES PROVIDE 5 /8 ° 0 DR. BOLT EMBED 3 MIN. EXIST. SLAB ON GRADE TRANSVERSE FRAME ELEVATION 1/2 " =1 3 /16 EACH POST EXIST. BRACES EXIST. POST 11/2 " =•-o" 13 14 S5.0 TOP & BOT. EA. BRACE e 6 /e" WITH (3) WO EAR BOLTS EMBED 4 MIN. 0 roc IQ S.5.1. CROSS BENT, EA. SIDE TYPICAL, U.O.N.. 9 55.0 EA. SIDE EXISTING CROSS MEMBER EXISTING OF CAROUSEL DIAGONAL BRACE FRAME OF CAROUSEL FRAME LONGITUDINAL ELEVATION OF CAROUSEL FRAME NOTE: BASKETS AND TRACK ETC. NOT SHOWN 3 „ =1 - 14 TRANSVERSE FRAMES OF CAROUSEL SEE S5.1W AND 05.2W FOR LOCATIONS OF NEW FRAMES AT WAREHOUSE CAROUSELS 14 WITH (2) 1 /2 "0 EXP. BOLTS EMBED 4 MIN. 0 B "oc TRANSVERSE FRAME SPACING 9' - MAX. 9 S5.0 EA. SIDE 14 S5.0 TAR & BOT. EA. BRACE EXISTING CAROUSEL BASE MEMBER 3 " =1' - 0" 10 WIRE SHELVING —_ UPRIGHT PROVIDE CLIP ANGLES AT EACH UPRIGHT AT APPROX. 6' -0" ABOVE F.F. ATTACH TO S11.11) w /(3) NO. B SCREWS. PROVIDE BLOCKING IN WALL IF STUDS DO NOT ALIGN w/UPRIGHTS -- STUD WALL - L ANGLE PER PLAN • NBBJ StlhJd+mArr6 706)2254560 Fet(205) 62200 Swenson Say Fag ®t M o' Serail 00101,0 CLIP ANGLE B 1 Je" .24 — A 4° LONG w/E WASHER , /8% 2" A 2" CLAMP TIGHT 11/2 "_ - 0 " 2TB"9 BOLT / /e WASHER 1 Ai x I 2" E0. AT WIRE POST CLAMP TIGHT �- WIRE SHELVING UPRIGHT 1 1 /2 " = 9' -0" 3 / + = - 0" 11 3/4 " =)' -5" 16 A Structural snsinw~o. Corporation NEW ROD BRACES PER 12/55.0 REAM EXISTING HOLE TO "AA' EXIST. FRAME POSTS AND BEAMS LONGITUDINAL FRAME ELEVATION 3 /i ii AR ROD --- PROVIDE TURNBUCKLE AT MIDPOINT AND WEDGE SHIMS AT EACH END EXISTING BEAM — NOTE: PROVIDE LONGITUDINAL BRACING AT EACH END BAY OF EACH ROW OF SHELVING, TYP. Group Health Cooperative of Puget Sand � EXIST. SLAB ( ON GRADE 3 " =1 '_ 0 " EXISTING POST 12/55.0 1y2 ° =1. -0" 12 13• -00 3/4' =1 -a 17 WAREHOUSE RACK STORAGE Riverton Operations Center 3 /4 " =1' -0" 18 9/29/96 3/4 " =1' -o" 19 Permit Submittal Poi DETAILS 10 55.0 SEISMIC BRACING aY As 4— 99313031 _.. .a Au ,MA. EXISTING TRANSVERSE / FRAME OF CAROUSEL T PROVIDE SPREADERS E 1 iD ° a12 ° TOP & BOTTOM AT EACH TRANSVERSE FRAME SIMILAR TO EXISTING END FRAMES / USE 9/55.0 AT BASE OF BRACED FRAME 0 55.0 v C EO „ o n o no EXIST. SLAB ON GRADE }.., _��. t� D`•11�1nN T/2 " =T -o° 20 Permit Submitt Maio JAN 3 11996 85 w OW NBBJ 111 South Jackson Street Seattle. Washington 98104 (206) 223 -5555 Fax (206) 621 -2300 3 4 5 2 A A 816.28 IN IN NI II MI N II I MINI 756.50 III s_ ui.n MN MI • IN S ■ n 1 II � 3 ID • 19 •20 121 IN El 1111110 III NI - - 13 14 15. I 1 17 18 �, 47.75 81.03 - 1 8.57 - 156 11 - 188.11 225.65 - 263.19 295.19 332.73 - 370.27 402.27 439.81 477.35 509.35 530.89 562.89 600.43 637.97 671.25 7 -19.00 C01024.5- 60- 10/18/3/8A.28 CAROUSEL LIVE LOAD = 60.000 LBS MACH NOT. = 12,900 LOS TOTAL WGT.- 72,900 LBS WGT. ON BASE: NOTE 1 1. 5755 LBS 12. 3190 LBS 2. 3620 LBS 13. 3390 LBS 3. 3250 LBS 14. 3190 LOS 4. 3390 LBS 15. 2590 LOS 5. 3190 LOS 16. 2590 LBS 6. 3190 LOS 17. 3190 LOS 7. 3390 LBS 18. 3390 LBS 8. 3190 LBS 19. 3250 LBS 9. 3190 LBS 20. 3A20 LBS 10. 3390 LBS 21. 5755 LOS 11. 3190 LBS 2. BASES ARE 4 INCHES WIDE BY 24.5 LONG. 1. ALL CALCULATIONS ARE WITH STATIC CONDITIONS ONLY. OR. MMGE DEE ux -DECeEEs ECi uAES s i ncE aEC iunES r HEAT TREAT 63.06 REM -0573 GROUP HEALTH COOP r NONE DONACEDID aE 01/11/96 c.a050 xn AYPpNO CORPORATION . aR EENE.N.,. �S 78 BY PAC. MR. NER x••x FOOTPRINT / TECH. PUB. FLOORLOAD I NG EuE ENa• ENee.APPRweE Ca. C01024.5- 60- 10/te/3/8A 5 3 B bcihoo5o CO 0 Group Health Cooperative of Puget Sound C D D WAREHOUSE RACK STORAGE Riverton Operations Center c U E E F CAD D. By DaQvin d 1/29/96 Permit Submittal Sled O sm. haw.d 4 1df DM. 40789.03 Dead 0 s a a.4 BOx 1/29/96 S5,1W 03 Pews COOT. Permit Submittal NBBJ 111 South Jackson Street Seattle, Washington 98104 1206) 223 -5555 Fax (206) 621 -2300 2 3 4 5 63.06 8.6 nfl 7.75- 81 .03-� 1 8.57 156.11 188.11 225.65 263.19 295.19 332.73 370.27 402.27 439.81 477.35 509.35 557.66 589.42 626.96 664.50 697.78 C01024.5- 62- 10/18/3/BA,28 CAROUSEL LIVE LOAD = 62,000 LBS MACH WGT. = 12,980 LBS TOTAL ROT.= 74,980 LBS WOO. ON BASE: NOTE 1 1. 5755 LBS 12. 3250 LBS 2. 3620 LBS 13. 3390 LBS 3. 3250 LBS 14. 3320 LBS 4. 3390 LBS 15. 3440 LOS 5. 3190 LBS 16. 3440 LOS 6. 3190 LOS 17. 3320 LOS 7. 3390 LBS 18. 3390 LAS 8. 3190 LBS 19. 3250 LOS 9. 3190 LBS 20. 3620 LAS 10. 3390 LBS 21. 5755 LBS 11. 3250 LBS 2. BASES ARE 4 INCHES WIDE BY 24.5 LONG. 1. ALL CALCULATIONS ARE WITH STATIC CONDITIONS ONLY. 842.81 783.03 Elm I =m i - .1 a 111 t4_ p15 II II II II II II I[J II II I I 745.53 ORANGE Egli : TxREE'PE r MATER AL REA, TREAT 18 f119 20 I I REM -0578 GROUP HEALTH COOP : NONE 2.61 0 0 A re 01/17/96 a.wx C.[NRYSIEfl THE RAYMOND CORPORATION . OeEEeE.e.Y. ��r78 BY . e . ' FLOORLOAD I NG vnw0 ERC. 0005.APVOov M'°. CD 1 024.5- 62- 1o/18/3/8A C 2 3 0 5 A B b9bc C Group Health Cooperative of Puget Sound Riverton Operations Center PHASE III D WAREHOUSE RACK STORAGE E F CAD D. By Neat. dPa. 1/29/90 Permit Submittal Shoe re. e.q.0 o.. 50 wee. 40789.03 add u2. 1/29/96 .50 JAN 3 1 1996 BEFtlarCEural Permit Submittal S5.2W NBBJ —0 • 9b0050 PHASE 17_ Li • Group c0 448 0 7g r h a ti ve WAREHOUSE RACK STORAGE of Puget bound Riverton Operations Center /-103-f4, • • • RC • BCA 1-26-96 RECEIVED CRY OF JAN 3 11996 000000r CORER S5.3W NBBJ OOOOCS d 0 0 0 O d l TYPE "A' RACK J Ci) EH T3 IL TYPE B RACK 0 )1 A ( 5'O = R,v_.TET T_�f (C2) rOD T SECVON D75 ➢1K PHASE e 11' -0' TYPE "B" RACK SCALE I iL D'LSi 404 LOAD . )EA`,..1 O O T -10' TYPE "C" RACK SCALE: I /4 " =I' -0' 0 0 u L1c n ROW SPACER Group de erativA WAREHOUSE RACK STORAGE oog of Puget bound Riverton Operetione Center (C2) 0 TYPE "C" RACK COALE. 1/4 -I' -O NOTES: I. PALLET RACKS ARE MFD BY LODI METAL TECH. INC., OF LODI, CALIFORNIA. 2 STEEL USED IN ALL RACK ELEMENTS CONFORMS TO A5TM A570 CR 50 WITH Fy =50 KSI, AND Fu 965 KSI. 3. STEEL USED IN ALL BASE PLATES CONFORMS 10 RUM A36 WITH Fy =36 KSI, AND Fu =58 KSI. 4 MAXIMUM RACK LOADS SHALL BE 5000Ibs PER LEVEL PER PAR OF BEAMS. 5 CONCRETE SLAB IS GIVEN AS 5' THICK, WITH To = 3000E' AND REINFORCED WITH WELDED WIRE FABRIC. 6. ALLOWABLE SOIL BEARING IS 3000 POP FOR GRAVIEf LOADS, AND 4000 POE FOR SEISMIC OR SEISMIC t GRAVITY LOADS. 7 ALL RACK UPRIGHTS ARE MODEL LA 20- 240 -44 B. ALL RACK BEAMS ARE AS FOLLOWS: A) LBF -404 -094 B) LBC -55 -132 9 BEAM -TO- COLUMN CONNECTIONS UTILIZE 3 AND 4 -PIN BRACKETS AND "A TYPE WELDS. 10. TIE -DOWN ANCHORS SHALL BE HILTI K1IIK - BOLTS. USE 1/2 "0x4 I/Z BOLTS, 0 3" MIN. EMBEDMENT, TWO PER BASE PLATE SPECIAL INSPECTION Ii REQUIRED AS SHOWN • RC BCA • I -Z6 -96 C RECENED CITY OF , JAN 3 1 1996 RawE CENTER S5. 4W