Loading...
HomeMy WebLinkAboutPermit B96-0043 - WESTERN GRAPHICS - MIX / DISPENSING ROOMCity of Tukwila t_ (206) 431-3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 BUILDING PERMIT Permit No: 896 -0043 Type: B -BLDG Category: ACOM Address: 12624 INTERURBAN AV S Location: Parcel #: 000480 -0003 Zoning: M -1 Type Const: III -N Gas /Elec: Wetlands: Water: TUKWILA Contractor License No.: Status: ISSUED Issued: 03/06/1996 Expires: 09/02/1996 Type of Occupancy: OFFICE Slopes: Y Sewer: SEPTIC TENANT WESTERN GRAPHICS 12624 INTERURBAN AV S, TUKWILA, WA 98168 OWNER THE SAMMIS COMPANY- 6755 S 216TH, KENT WA' 98032 CONTACT DAVID BROWN.: 1628 SIXTH.AVENUE,WEST, °SEATTLE, WA 9.8119 Phone: 206 872 -9600 Phone: 206 281 -8787 * * *'k * * * * * * * *k * * **lc* Ir*********** k** k********** *** * *** * **.***** *** ** * *k*** **** Permit Descri'pt•ion: CHANGE:. A' CONTROL AREA TO, A TWO HOUR MIX /DISPENSING ROOM Units: 001 Buildings: 001' Fire Protection: UBC Edition: 1'994 Va l uat i on; 1 ,'200.00 SETBACKS Front: .0 Back: Left: .0 Right: Total Permit Fee: 70.91 * * * * * * ** * * * * * ** * * * ** ** k***** ** * * * * *** * * * ** * * * * k * * * * * * * * ** k * * **k ** k kk* * * * * ** tazi Perm t Center Authorized Signature. Date I hereby -certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing;this work will be complied with, whether specified herein or not The granting of this permit does not presume to .give authority to violate or cancel 'the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this building permit. Signature: Print Name:___1C�.1�^�ri Date: 3-4 �G Title: _Ce?+t,.rrk -( This permit shall become 'nu1l:;,and; void:` if the 'work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 130 days from the last inspection. DEPARTMENT • DATE IN DATE APPROVED RE QUIREMENTS !COMMENTS V1 BUILDING - initial review a "�-�(� 3 2,- ?z-cvp 4. (ROUTED) CONSULTANT: Date Sent - Date Approved - X FIRE �'� -�� I^ 2.... ' Y' FIRE PROTECTION: ( Sprinklers (J Detectors N/A F IRE DEPT. LETTER DATED: 2 - '2-6--- ( R.. INSPECTOR. M- - ./ /0 INIT: ,. )11/ 120 O PLANNING 1 1 • ZONING: BAR/LAND USE CONDITIONS? ( )Yes ( ) No REFERENCE FILE NOS.: INIT: MINIMUM SETBACKS: N- S- E- - N PUBLIC WORKS i, .a UTILITY PERMITS REQUIRED? •j Yes 'No • PUBLIC WORKS LETTER DATED: • INIT: O OTHER INIT: j� BUILDING - final review -_ Zc.Z i'r� �c-(_ 2_. ( a TYPE OF CONSTRUCTION: \114 CERT. OF OCCUPANCY? QYesNo UBC EDITION (year): (�� /' `-I�' • INIT: 4<446 BUILDING OFFICIAL 2- 2`'t -% voht INIT: -- AMOUNT OWING: CONTACTED �/y�,� /� 1 ► lC S h 7 " DATE NOTIFIED — q / BY: init. 2nd NOTIFICATION BY: 3RD NOTIFICATION BY: (init.) PLAN CHECK NUMBER CITY OF TUKWI14e Department of Cori)munity Development — Permit Center 6300 Southcenter Boulevard - #100, Tukwila, WA 98188 (206) 431 -3670 Building Permit Application Tracking REVIEW COMPLETED PROJECT NAME W.& C Y cW h\ LO SITE ADDRESS SUITE NO. INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that the status of the project may be ascertained at any time. • Plan corrections shall be completed and approved prior to sending to the next department. • Any conditions or requirements for the permit shall be noted in the Sierra system or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ", date and initial. DEPARTMENTAL REVIEW "X" in box indicates which departments need to review the project. 01/08/99 SITE ADDRESS SUITE # 12Z(Z4 ir+ -0 wet& ivy • VALUE OF CONSTRUCTION - $ j2ot> ASSESSOR ACCOUNT # 00 0- Doi PROJE T NAME/TENANT 1 ' - '1 4 I & TYPE OF 0 New Build ng • Addition Li Tenant Improvemen WORK: 0 Rack Storage 0 Reroof 0 Remodel (residential) (commercial) Demolition (building) 0 Other DESCRIBE WORK TO BE DONE: 7 � 114 A . / 9- BUILDING USE (office, warehouse, etc.) NATURE OF BUSINESS: ,f 1!44 'F.- / /V r4 A-1 WILL THERE � BE / A CHANGE IN USE? 0 No XYes If Yes, new building requirements may need to be met. Please explain: .D # 1 T4 y - L�1 'Gect -- .}� `�Z - i'b 742 ' o ' jF. SQUARE FOOTAGE - Building: Tenant Space 4 Area of Construction: — e , .G WILL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR AZARDOUS MATERIALS IN THE BUILDING? 0 No 1,6 Yes IF YES, EXPLAIN: ZOH$ aSTI ��- FIRE PROTECTION FEATURES: Sprinklers CY Automatic Fire Alarm System PROPERTY OWNER ' rI N/. Te-y6. (413-947-44-p-4 BUILDING OWNER OR AUTHORIZED AGENT iPHONE ,77 .„14,0p — d °! ZIPiezo32 ADDRESS .(7- "J Ole d Gib. -7-' eY/� lzI CONTRACTOR � / ‘,,,,fri PHONE 2 ADDRESS _ WA. ST. CONTRACT R LICENSE # /.., ? f��j EXP. DATE ' PHONE ARCHITECT �x - � �_ � t ADDRESS LL17P, l d 1 \ t � / E_ I ZIP '7`is1 i I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND. KNOW THE SAME TO BE TRUE AND CORRECT, AND AM AUTHORIZED TO APPL FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT SIGNATURE DATE 2� PRINT NAME vip � / ‘,,,,fri \ ,/ u PHONE ,ii/ -i ?8 7 CITY/ZIP 14 ADDRESS iir ' CONTACT PERSON PHONE 2 ) — �'ffi CITY OF TUKWILA Department of Community Development - Building Division 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 APPLICATION MUST BE FILLED OUT COMPLETELY PLAN CHECK NUMBER H OOL BUILDINu PERMIT APPLICATION DESCRIPTION BUILDING PERMIT FEE PLAN CHECK FEE BUILDING SURCHARGE OTHER: TOTAL - AMOUNT Voti 4Jo RCPT #1 DATE APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. Handouts are available at the Building counter which provide more detailed information on application and plan submittal requirements. Application and plans must be complete in order to be accepted for plan review. VALUATION OF CONSTRUCTION Valuation for new construction and additions are calculated by the Department of Community Development prior to application submittal. Contact the Permit Coordinator at 431 -3670 prior to submitting application. In all cases, a valuation amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Building Division to comply with current fee schedules. BUILDING OWNER / AUTHORIZED AGENT It the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitations. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Building Code (current edition). No application shall be extended more than once. If you have any questions about our process or plan submittal requirements, please contact the Department of Community Development Building Division at 431 -3670. DATE APPLICATION ACCEPTED DATE APPLICATION EXPIRES 0 1012293 :OMMERCIAL :EW COMMERCIAL BUILDINGS /ADDITIONS J Completed building permit application (one for each structure) 1 Assessor Account Number Two sets (2) of the following: Specifications Structural calculations stamped by a Washington State licensed engineer Soils report stamped by a Washington State licensed engineer Topographical survey ] Energy calculations stamped by a Washington State licensed engineer or architect 7 Legal description 1 Working drawings, stamped by a Washington State licensed architect, which include: • Site plan • Architectural drawings • Structural drawings • Mechanical drawings • Elevations • Civil drawings • Landscape plan. RESIDENTIAL SUBilVVfITTAL CHECKLIST Completed utility permit application (one for entire project) I Six (6) sets of civil drawings NOTL: See utility permit application and checklist for specific utility submittal requirements. RACK STORAGE 1- 1 Completed building permit application L I Assessor Account Number Two (2) sets of plans, which include: Building floor. plan showing: • Entire space where racks will be located • Exit doors • Dimensions of all aisles Tenant space floor plan showing rack storage layout, aisles and exits. NEW SINGLE - FAMILY DVJELLINGS /ADDITIONS I J Completed building permit application (one for each structure) Structural calculations stamped by a Washington State licensed engineer (rack storage 8' and over). NOTE: Include dimensions of racks (height, width and length), aisles and exit ways on plan. Legal description Li Assessor Account Number n Two sets (2) of working drawings, which include: • Site plan -r (On plan, show closest hydrant location. • Foundation plan Include access to building, showing • Floor plan width and length of access.) • Roof plan • Building elevations (all views) . • Building cross - section • Structural framing plans Washington State Energy Code data Completed utility permit application . J Six (6) sets of site plans showing utilities NOTE: Building site plan and utility site plan may be combined. See utility permit application and checklist for specific submittal requirements. Additional topographical and soils information may be required if unique site conditions. COMMERCIAL TENANT IMPROVEMENTS • Completed building permit application (one for each structure or tenant) • Assessor Account Number Two (2) sets of construction plans, which include: Site plan • Location of tenant space • Existing and proposed parking • Landscape plan (if applicable, i.e,, change of use) n Overall building plan • Tenant location • Use of adjacent (common wall) tenant • Overall dimensions of building or square footage Floor plan of proposed tenant space •.Tenant space plan with use of each room labelled. • Exit doors, egress patterns. • New walls, existing wall, and walls to be demolished. n Construction details • Cross sections showing wall constructicr, and method of attachment for floor and ceiling, El Structural calculations stamped by a Washingtor, State licensed engineer may be required it structural work is to be done (2 sets) NOTE: If any utility work is to be done, submit separate utility permit application and plans. REROOF Completed building permit application (one for each structure) Assessor Account Number l Narrative describing existing roof, material being removed, and LJ material being installed. NOTE: A certification letter is required prior to final inspection and sign- off of the permit. ANTENNA/SATELLITE DISHES Completed building permit application Assessor Account Number Two (2) sets of plans, which include: F. Site Plan (showing building and location of antenna/satellite dish) I I Details antenna/satellite dish and method of attachment Structural calculations stamped by a Washington State licensed engineer may be required RESIDENTIAL REMODELS Completed building permit application (one for each structure) Assessor Account Number Two (2) sets of working drawings, which include: • Site plan • Foundation plan •.Floor plan Roof plan • Building elevations (all views) • Building cross - section • Structural framing plans NOTE: If any utility work is to be done provide utility permit application and plans must be submitted. REROOFS [ Completed building permit application (one for each structure i 1 Assessor Account Number n Narrative describing existing roof, material being removed, and material being installed. NOTE: A certification letter is required prior to final inspection and sign - off of the permit. CITY OF TUKWILA Address: 12624 INTERURBAN AV S Permit No: B96-0043 Suite: Tenant:. WESTERN GRAPHICS Status: ISSUED Type: B-BLDG Applied: 02/13/1996 Parcel #: 000480-0003 Issued: 03/06/1996 le*kkA******************k*****kA*******A**VILA**** Permit Conditions: 1. No changes will be made to the plans unless approved by the Architect or Engineer andthe_TuLwila Division. Plumbing per sha11- the Seattle-King County of Heaiti). Plumbing will be inspected by thAtaijancy,,,:incOudirfg all gas.4qping (296-4722). 3. ElectricalkarMit:khal State DivfOiin of Labor and Indutries and all electrical work 01 by that agehCy.(248 4. All meolianicil Wor k shill be under separit,e permtt:issu'ed by the CY,ty,:ofY1 5. All Wejjnits, insOotion and approved shalljle aa1iahle at the prior to the start of any con stry0ionThese dcwillientslire/to be maintained. arid. ins is granted. 6. Al to13e conformance with approved plans wld'requiremenS'.of the Uniform,Bulldinq Code (1994 . Edition; as emended, Uniform Mechanical Code (1994 EdItiop):,. arieWashigtOn:=State'Efferiiv Code (1994 Edftion). e 7. ViT Permit ; The of .aper'mit or approval of pliOs„,specificationsand'. shall not be c66- strvad . tObea permit fat or an approval at, any violatinn ofa'nyof the prOiiiion's'of the bui11'no' 'coda or of any othr or dItiance of the jurisdictlop.'. No permit presuMillg to clive violate or cancel the.provi'sions code : valid. - This Payment A++***+***+**+*++ TRANSMIT Number: Payment Method: -`--`-`--`.- -'-` Permit No Parcel No: Site Address Account Code 000/322.100 CITY OF [UKNILA, NA ++*+++*+*+4*k*++**++* ++A*a+*+++++*++h+*A**++A+k*+*+*+*A°+k*^***++ w ow 96003612 Amount: (NECK Notation: ________________ r 896-0043 Type: 000480'0003 12624 INTERURBAN AV S |RANSMIT +++++k++* + 7O.91 0 2/ I /9l7 B[:46' DAVID BROWN ASSU Init: SLU 8'ULD6 BUILDING PERMIT ''-`--'~'.-'-'-'-- Total Fees: 70.91 70.91 Total ALL Pmts: 70.91 Balance: .00 +-A4*^*** Description Amount BUILDING - NONKES 40.25 000/345.830 PLAN CHECK - NONRES 26.16 000/386.904 STATE BUILDING SURCHARGE 4.50 GENERA 70°91 TOTAL 70.91 CHECK 70.91 CHANCE 0.00 2658A000 15:51 Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre-Fire: Permits: c , City of Tukwila Fire Department L.41 • • ••• ■‘ 1 4, 1. '.1V TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Project Name Address I - 1 17 1,1 1A-a, it , 4 i i X Retain current inspection schedule Needs shift inspection k Approved without correction notice Approved with correction notice issued Thomas P. Keefe, Fire Chief Permit No. 10()Y John W. Rants, Mayor Suite # M V-2 7 Co Authorized Signature Date FINALAPP.FRM T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206) 575-4439 Project: , d..'..... .....i., , ' Type of inspe• ion. / Address: Date called: Special instructions: / 3 D Date wanted: 1 7 4- 2_6 "-9 6 / Z, Requester: Phone No.: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 9818 COMMENTS: Approved per applicable codes. $42.00 REINSPECTIO FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECOR Retain a copy with permit it PERMIT NO. I 1 Corrections required prior to approval. Date: 670 Projecti 61241;oics Type of inspection: Fit\I A , fa I — c ef Lk . ifirseuRSAN N S Date called: I A _ _ _ 9 b Special instructions: Date wanted4 _ 2_1 a.m. (67r79 Requester: Phone No.: 872. 9 , • VlatTZGOSIUMPIRMalivOrosenteswes.r. n Approved per applicable codes. INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 [Kborrections required prior to approval. COMMENTS: %) tTS - o o4 reli —0 A}A9 vyic15 - 0111 I Inspector: Date: 14 t( ((1 $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: : Date: -40-o0-15 PERMIT NO. (206) 431-3670 • Project: W V�PY f\ G (( li r j Type of inspection: WL 'a SJ Address: Z(10-4 i (V Date called: . . 3 - c Special instructions: Date wanted: Requester: Q OG -eY [ Q � o Phone No.: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 981 0(0-00(0 PERMIT NO. (206) 431 -3670 CO5MMENTS: 4i) Inspector: If Date � � Approved per applicable codes. Receipt No.: Corrections required prior to approval. $42. R EINSPEC ION FEE REGIUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: pro J ect we5rax eilzApHics Type of insnectiory - Arr. WS NA 11-) &10 i■Z,4 immiii esA A v Date called: 5 - 2 1 Special instructions: 5 Date wanted;, _ 2... ,..9 ( Requester: 1.---. \ o el EP- Phone No.: .0 — 39 00 pproved per applicable codes. INSPE N INSPECTION RECORD Retain a copy with permit • CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 IA - 0o-13 PERMIT NO. (206) 431-3670 COMMENTS: /-e/tIte- Corrections required prior to approval. $42.00 REINSPE N E RED IRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Projec;� . I_: ■,_ S ° I a . L..1 Address: J'?.- Z 4 Y T^V' 4�N t � A Ty of inspection I Date called: Special instructions: Date wanted: 3 Z. tetf i r/i; r . Requester: Phone No.: _ / - 39 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. INSPECTION RECORD Retain a copy with permit (206) 431 -3670 [;Er COMMENTS: f r r 2 S `fly G wE3 I Inspector: Date: Corrections required prior to approval. FT $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. l Receipt No.: Date: Project: /�^'^ � C. .,I. e,,> Type of inspectio�: � � Address: 2 ( Date called: Special instructions: 2 7Q 3:o0 Date wanted: 3 v 9,- ' � �' Requester: Phone No.: 63 1r- p KIApproved per applicable codes. COMMENTS: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 I I PERMif NO. (206) 431 -3670 , xi p CE1 +JG gfLtA I G tZk"CT .A:=CiVtA tA AP Pr�vA'- Inspector: Date: . 3h Corrections required prior to approval. $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: City of Tukwila Fire Department Fire Department Review Control #B96 -0043 Re: Western Graphics - 12624 Interurban Avenue South Dear Sir: February 27, 1996 The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. Rooms classified as flammable liquid use, dispensing or mixing shall be constructed in accordance with the Building Code. (UFC 7903.2.3.2.1) Thomas P. Keefe, Fire Chief 2. Maintain sprinkler coverage per N.F.P.A. 13. Addition /relocation of walls, closets or partitions may require relocating and /or adding sprinkler heads. All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recognized by The City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1742) 3. Mechanical ventilation shall be in accordance with the U.B.C. and U.M.C. codes. (UFC 7903.2.3.4.2) 4. Spill control is required by U.F.C. 7903.2.3.4.4 and shall be constructed in accordance with U.B.C. 307.2.3 (4" sill, sealed liquid tight) 5. Exit doors shall swing in the direction of exit travel John W. Rants, Mayor Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 5754439 r Yours truly, City of Tukwila Fire Department Thomas P. Keefe, Rre Chief Page number 2 when serving any hazardous area. (U.B.C. 1004.2) 6. Provide a minimum 2A 20BC extinguisher within 10' of your flammable liquids use, dispensing and mixing room. (UFC 7902.5.11.5.2) 7. All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. The Tukwila Fire Prevention Bureau cc: TFD file ncd John W. Rants, Mayor Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206) 5754439 . • . • . . , • • REGISTERED AS PROVIDED BY LAW AS A: CONST CONT GENERAL REGIS: cTRA.c3 L P 18802 BARDEEW :AVE IRVINE 'CA: :9g715-1521 SIGNATIJE4F-, :• ." ' ... • • , . . • • . . • . . . " • , • .• . • • • • , • •.. , • REGISTRATION c rosiolin 7 04 .. • 01. -- - - ...EFFECTIVE 2 DATE . • . • . . , • • REGISTERED AS PROVIDED BY LAW AS A: CONST CONT GENERAL REGIS: cTRA.c3 L P 18802 BARDEEW :AVE IRVINE 'CA: :9g715-1521 SIGNATIJE4F-, :• ." ' ... • • , . . • • . . • . . . " • , • .• . • • • • , • •.. , O O O EXISTING OFFICE EXI6TG VG.T. TO REMAIN EXISTING E E D; .-ONC. TO REMAIN EXISTING DARK Itl1. EXISTG SEALED. :CNC. TO REMAIN FLOOR PL14N SHELL. 4,785 S,F, DFFICE' 2,000 S.F. 2 -HR RATED WALL ASSEMBLY PER I /AI EXISTING 9 6' TYPE 'x' GYP. BD. TYP. EXISTING MTL. STUDS 6' RATED MTL. DOOR JAMB /ASSEMBLY I V2 HR FIRE RATED MTL. DOOR ® 1 ° HR. RAND DR. (wimp 61M) SCALE: 3' • 1' -0' 43' -6' EXITING RECE ./OFFICE EXISTING CARPET TO REMAIN EXISTING ST TO REMAIN f NEW I Vx HR F RE RATED MTL. DOOR AND JAMB ASSEMBLY w/ CLOSURE EXIT TOOL MIXING/ XI ED TO MIXING/ DI ING RM. SE ALED CONC.. FL. s 4' CURD* MIX /DISPENSING ROOM 2 -HR TRACTION PER DETAILS SEAL CONC. 1 % ZING AD SEC I ONAL T RICK OVERHE DR e o EMIR"' OF FICE EXISTS CARPET TO REMAIN EXISTING STL. TUBE COLUMN TYP. EXISTING TIOLET ROOMS TO REMAIN SCALE V • • I' -0' a olto NORTH d O RAMP DOOR 311.E 2 SCALE: 3' • I' -0' EXISTING CONC. SLAB FILE COPY 1 un.'.--L -_ • t 1,0 Plan Chu ..' sub•. : to c..o and omissions plc^. dons not sutoS. O violation or aCapted node at 011.1115111505t 08 contractor's copy cr apprass7 /WEE Dots . 3 - G -91 Pond No. , Iq 10 O(711 - 7 EMEND EXISTING GYP. BD TO NEW HIGHT AS REQ'D. 2 -HR CEILING SYSTEM PER GA FILE NO. FC5T24 AS FOLLOWS: BASE LAYER Ws' PROPRIETARY TYPE 'X' GYPSUM WALLBOARD OR VENEER BASE, APPLIED AT RIGHT ANGLES TO 2010 WOOD JOISTS AT IS 00. w/ Sd NAILS 2/' LONG, 0.133' SHANK, 13/64' HEADS, AT 1' O.C. FACE LAYER 1 16' PROPRIETARY TYPE 'X' GYPSUM WALLBOARD OF VENEER BASE APPLIED AT RIGHT ANGLES TO RESILIENT FURRING CHANNELS w/ TYPE '5' DRYWALL SCREWS 12' O.C. RESILIENT FURRING CHANNELS SPACED AT 24' OZ. AND NAILED AT RIGHT ANGLES TO JOISTS AND THROUGH BASE LAYER WITH ONE 73a1 NAIL, 211' LONG, 0.113' SHANK, 13/64' HEAD, AT EACH JOIST. DOUBLE CHANNEL INSTALLED AT BUTT ENDS OF FACE LAYER WOOD JOISTS SUPPORTING I' NOMINAL TAG WOOD SUB AND FINISH FLOOR PERPENDICULAR TO JOISTS WITH JOINTS STAGGERED. EXISTING 3E5' MTL. STUDS of I W'a' TYPE 'x' GYP. BD. EA. SIDE TYP. REVISIONS NO CHANGES SHALL BE MADE TO THE SCOPE OF WORK WITHOUT PRIOR APPROVAL OF TUKMLA BUILDING DIVISION. NOTE: REVISIONS WILL REQUIRE A NEW PLAN SUM,. AND MAY INCLUDE ADDITIONAL PLAN REVIEW FEES. EXISTING SILL R ATTACHED TO EXISTING CONC. SLAB MTL. DR. JAMB BEYOUND CONTAINMENT CURBING 5 4' EXTERIOR GRADE PLYWD. RAMP AT DR OVER 2x RIPPERS TYP. CITY OF TUI(WILA APPROVED FEB 2 9 1996 An nOlbU BUILDING MVO N SEPARATE PERMIT REQUIRED FOR: 2/MECHANICAL ELECTRICAL ❑ PLUMBING 0 GAS PIPING C r,' OF TUKWILA BUILDING DIVISION EXISTG WALL ADD ITION OF 2 HR L RATED WALL SYSTEM 1 11111 NE 2x10'' o IS' O.C. INSTALLED AL SIDE THE EXISTING MTL. JOISTS NOTE: EXISTING TYPE 'X' GYP. BD. RE CEILING MAY REMAIN AND BECOME A PART OF THE RATED CEILING ASSEMBLY EXISTING CEILING STRICTURE MAY REMAIN AT CONTRACTOR'S OPTION 2 -HR RATED WALL CONSTRUCTION PER GA FILE NO. WP1841 AS FOLLOWS: ONE LAYER V2 PROPRIETARY TYPE 'X' GYPSUM WALLBOARD OR VENEER BASE, APPLIED PARALLEL TO EACH SIDE OF 1'024' PROPRIETARY TYPE 'X' GYPSUM PANELS w/ LAMINATING COMPOUND COMBED OVER THE ENTIRE CONTACT SURFACE AND w/ 1 5/16' TYPE '5' SCREWS SPACED 24' O.C. HORIZONTALLY AND VERTICALLY. EACH P GYPSUM PANEL ATTACHED TO 25 GAGE I•x2V4' HIGH 'L' RUNNERS ALONG FLOOR AND CEILING LINES WITH TWO I SAW TYPE 'S' SCREWS AT TOP AND BOTTOM. WALLBOARD LAYERS ATTACHED TO •L' RUNNERS w/ Bs' TYPE •5• SCREWS 12' O.C. STAGGER JOINTS 12' O.C. EACH LAYER AND EACH SIDE CONC. CONTAINMENT CURB OR 24 GAGE 6'x 2' 'L' MTL. BASE FLASHING SCREWED TO EACH STUD AND SEALED TO FLOOR w/ SILICON SEALANT EXISTING CONC. SLAB 1.1141-1- SECtION 2 -1-IR UP -GRADE P1-14N W/ OVERR41.1- SUIJ.DING "B" SHOWN GENERAL REOJIRQT'IENTS I. General Contractor shall visit Job site and verify all grades, dimensions and existing conditions on site and notify the Architect of any dleaepancies prior to commencing work 2. General Contractor shall give all notices and comply with all laws, ordinances, rules, r e the (including materials/ and orders or any pertinent public authority bearing e perroxmance or the work and shall notify the architect Ir the drawings are at variance herewith 3. All work shall comply with the latest edition or the **worm mullding Code and all other applicable codes. 4. General Contractor stall be 9ov ed by ail conditions as Indicated In contract drawings and spscl /loatlone for the building. 6. The Contractor Is to provide all work services and materials necessary to construct a complete raclllty. 6. Tine Contractor I. to notify the Architect or any discrepancies In dimensions. Do not scale drawings. The e General Contractor shall be resuonslble non cocrdlnating the work or ail trades a nd supplies ran prop sequence of work to avoid dupllatlon of effort and provide an orderly progress or work e. General Contractor stall consult plans of all trades for ducts, piping, conduits, e cabinets, and equipment and shall vrlry elms and locations or op Inge through slabs n d walls wlih o trades. O Cabal Contractor contractor to provide all wood backing furring, stripping or blocking Indicated or required for Installation and attadm or work or all other trades. Cut and Name all openings required by other trades, IV. Obtain for a separate perm nor all addition or modlrlatione to, Mechanical Fire Protectlon/Alarms Mrs sprinkle System Electrical II. Each subcontractor to obtain all the required permits and approvals rot their portion or the work 12. Each subcontractor Is responsible for the repair of any damage to finished work en adjact to their work when such damage Is a result or their action and shall be performed at their expense. 13. Each subcontractor at the completIon or their work le to remove all their debris from the site leaving the building broom clean. 14.5o not block exits during construction. DOORS a WINDOWS 510. All new or relocated doors shall have their hardware changed to latdeets with either lever or push operated by wrist or arm pressure, as requIred by Washington State pannier Free Regulations. PMISNES 16. Contractor Is requIred to field verify the existing slab /sub - flooring conditions. Any required slab /sub - flooring preparation required prior to Installation or finished flooring Is wIthin the coops or work contained herein. 11. All areas of cone slab that do rot receive a rinlsh d floor are to be cleaned and sealed with a clear concrete floor sale. I8. Painting to has one coat of latex primer and two color coats or latex. Cole per tenant's instructions. SPECIALTIES 2"A 2015 I9, FrovIde (113 -A G m I0E Fire extinguisher, eetlrgii6- Sedr'O•Fper - 3,�Sa wIth a max. travel dIstance of 7behceemectVgM U ,are � %4 ( MECHANICAL to era line NyrY..yaS o.•�. f 20.E addition or modifications to the Fire Sprinkler System shall have fire department lea and approval or drawInge prior to Installation or modification. 21. Provide exhaust ventilation from a point not more than 6' above the finished floor Insight, to and through the roof per the Mechanical Coda. Exhaust vent fan to has wired to light swabs so that It opperates at all times that the II9gho Is on. Provide a make up air supply with a fussed closure per the Madaniai Code. manual 23. Provide a manual shutoff for the required ventilation equipment, outside the entry door. The swItch shall be or the break -glass type and shall be labled'Ventllatlon System Emergency Shutorf' ELECTRICAL 24. Replace existing IIght In Mlxing/Dlepencing roam with explosion proof light. LEGAL ONSCRIPTION MOM P491101.11.1 De00,13.93 0107870=j= 2=1:4SC 1 SCALD, I" • 100' CODs DATA Land ZOrie. Existing Parking iota:. 260 SP.. flECEWFD CITY OF TUISVfIIA FEB 1 3 1996 PERMIT CENTER Jr A a) co V) N O 0 m T . • co m U o td e c C 43 4) U) N J t10 F--I 0 I to -- �+ ci O W T v1 .N H-0 C V Woo... FEB. 6 1996 A A s and SpeCiFicatonS, a. '''' cr r ■I P; t 1t: ;;:c i t l f; e Wow' voltten COnsant and NP 95120.01