Loading...
HomeMy WebLinkAboutPermit B96-0057 - HEATCON - STORAGE.! City of Tukwila S. , (206) 431 -3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 BUILDING PERMIT Permit No: B96 -0057 Type: B-BLOG Category: ACOM Address: 600 ANDOVER PK E Location: Parcel #: 262304 -9100 Zoning: CM Type Const: RACKS Gas /Elec: Wetlands: Water: N/A Contractor License No.: Status: ISSUED Issued: 03/19/1996 Expires: 09/15/1996 Type of Occupancy: WAREHOUSE Slopes: N Sewer: N/A TENANT HEATCON 600 ANDOVER PK E, TUKWIL.AWA,.98188 OWNER HEATCON 600 ANDOVER PARK. E, TUKWILA WA 98188 CONTACT TIM BOUSHEY 600 ANDOVER PK E, TUKWILA WA :98188 Phone: (206) 575 -0815 Phone: 206 575- 0815 ** k* kk* kk******* k***** k**** k*** k********** k* ** * ** * ** **A *k *•k * * *k* * * *kk * * *k ** Permit Description: ASSEMBLE USED. MEZZANINE IN WAREHOUSE TO HOLD SMALL ITEMS OF INVENTORY. SETBACKS Units: 001 Front: .0 Back Buildings: 001. Left: .0 Right :_ Fire Protection: SPRINKLERED /AFA UBC Edition 1994.' Valuation: Total Permit Fee: 2,000.00 107.21 ****** A******************************•****. * * * ** * * * * ** * * * * * * * *• * * * * *k * * ** *kip•* Permit Center Authorized Signature Date� I hereby, certify that I have read and' examined this permit and know the same to b.e true>and correct. All provisions of law and ordinances governing.this. work will be complied with whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state. or local laws regulating construction or the :perfor.rnance of work. I am, authorized to sign for and obtain this bung p Signature:_ Print Name: Date: 01 t1A2T.C2. Title: _,2LJADuc_770V r1.�1fi6�F�C_ This permit shall become'nul.l: and void "•if the ,work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. DEPARTMENT DATE IN TIATE ',APPROVED'. ., ` ?REQUIREMENTS /.:COMMENTS � ` ( Plan Review Meeting d -% 0-ar fD (init.) NIT: —C4 X BUILDING - Irntlai 4eview / NSULTANT: ( OU ED) Date Sent - Date Approved - 3RD NOTIFICATION WARE G ) v /(o / x,19 0 FIREPROTECTION: Sprinklers 0 Detectors WA `IREDEPT.LETTERDATED 31 I CI tp INSPECTOR: 0. C j NIT: so_. [PLANNING .4 ° \1����J ZONING: PAR /LANDUSECONDITIONS? DYes 0 No D EFERENCE FILE NOS.: INIT. MINIMUMSETBACKS: N- S. E- W- p PUBLIC WORKS N Ps J S5 UTILITYPERMITSREQUIRED? D Yes ❑ No PUBLIC WORKSLETTER DATED: INIT Q "BUILDING - final review 3 12 CI( O TYPEOFCONSTRUCTION: PI-C46S CERT.OFOCCUPANCY ? Oyes No UBC EDITION (year): \k Li INIT: 0 BUILDING OFFICIAL 9 2 ,-j, CK, <-?) ) I V ( 1(9 INIT: � �) AMOUNT OWING: i O CONTACTED DATE NOTIFIED Q - G `'3 ---I l n 1 ` V•' (init.) f 2nd NOTIFICATION BY: (init ) 3RD NOTIFICATION BY: (init.) PLAN CHECK NUMBER BCJcp - 0057 REVIEW COMPLETED CITY OF TUKWILA Department of Comm�-rity Development — Permit Center 6300 Southcenter Boulevard - #100, Tukwila, WA 98188 (206) 431 -3670 Building Permit Application Tracking PROJECT NAME i-ica4cgon S17'E V ES J , )dC fr f�I1 l_-- SUITE NO. INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that the status of the project may be ascertained at any time. • Plan corrections shall be completed and approved prior to sending to the next department. • Any conditions or requirements for the permit shall be noted in the Sierra system or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N/A ", date and initial. DEPARTMENTAL REVIEW "X" in box indicates which departments need to review the project. 02)15196 SITE ADDRESS SUITE # (0o Aw1ovt- AUK EAST V LUE OF CONSTRUCTION - $ 4c2 ) 000 , OD ASSESSOR ACCOUNT # gCQ9.3O f fOO (commercial) (] Demolition (building) g Other NE.41 MEZZANINE 11 V4 EM PROJECT NAME/TENANT HEAT /g , INC. TYPE OF O New Building Li Addition (] Tenant Improvemen WORK: O Rack Storage C Reroof ❑ Remodel (residential) DESCRIBE WORK TO BE DONE: A 5 s maLY OF asc..L rIE.Z"2_09-41/NE. lA/ AP12 .deuS,E j* To t-/oa) SM ,9LL /Tl_ -'"n5 6F /NVE .NTaa_Le • BUILDING USE (office, warehouse, etc.) OFFICE/ w ARE-NouSE_ NATURE OF BUSINESS: lNp(.46TR/l4L E1&G71VC HEAT 4NO C v77204. 6 /ST/{,Qu7a>2 WILL THERE BE A CHANGE IN USE? X No Yes If Yes, new building requirements may need to be met. Please explain: SQUARE FOOTAGE - Building: ac/ Scy0 Tenant Space: Area of Construction: 5 WILL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING? X No O Yes IF YES, EXPLAIN: FIRE PROTECTION FEATURES: 54 Sprinklers RI Automatic Fire Alarm System PROPERTY OWNER N owAkD l`6ArlASKY 1PHONE KNOW THE SAME TO DATE 30 N)1J C I cS PHONE 6 _ 57S- -Dg /S CITY/ZIP .Ir ?gin PHONE� S75 -d gl5 575 - D8/5" ZIP 721ES 7 -7610 ADDRESS ( ANDOVER, pox_ EA S FATCI.F_ _ WA CONTRACTOR PHONE ADDRESS ZIP WA. ST. CONTRACTOR'S LICENSE # EXP. DATE ARCHITECT PHONE ADDRESS !ZIP I HEREBY CERTIFY THAT I HAVE • AD AND EXAMINED THIS APPLICATION AND BE TRUE AND CORRECT, AND 11' AUTHORIZED TO AP FOR THIS PERMIT. KNOW THE SAME TO DATE 30 N)1J C I cS PHONE 6 _ 57S- -Dg /S CITY/ZIP .Ir ?gin PHONE� S75 -d gl5 BUILDING OWNER OR AUTHORIZED AGENT SIGNATURE , E/ 1 •, ./' /' . . Li PRINT NA flo�AKD .QA/II�IS ADDRESS 600 #4A1D01. meK EAST CONTACT PERSON —r e at/ -W ? DESCRIPTION AMOUNT RCPT # DATE BUILDING PERMIT FEE (o ,,1..9 D►U(o `/, 56 is ; • ' ` PLAN CHECK FEE BUILDING SURCHARGE OTHER: TOTAL - /6 7... / CITY OF TUKWILA Department of Community Development - Building Division 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 APPLICATION MUST BE FILLED . ;OUT COMPLETELY PERMIT CENTER BUILDING PERMIT APPLICATION APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. Handouts are available at the Building cuuliter which provide more aetai{ed information on application and plan submittal requirements. Application and plans must be complete in order to be accepted for plan review. VALUATION OF CONSTRUCTION Valuation for new construction and additions are calculated by the Department of Community Development prior to application submittal. Contact the Permit Coordinator at 431 -3670 prior to submitting application. In all cases, a valuation amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Building Division to comply with current fee schedules. BUILDING OWNER / AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitations. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Building Code (current edition). No application shall be extended more than once. If you have any questions about our process or plan submittal requirements, please contact the Department of c. Development Building Division at 431 -3670. DATE APPLICATION ACCEPTED �►��.) 1 & EB 2 `S 199 DATE APPLICATION EXPIRES g-- J-3 - c/ 1 OJ22iOJ 3OMMERCIAL NEW COMMERCIAL BUILDINGS /ADDITIONS — 1 Completed building permit application (one for each structure) I Assessor Account Number Two sets (2) of the following: I1 � I I) Specifications Structural calculations stamped by a Washington State licensed engineer Soils report stamped by a Washington State licensed engineer Topographical. survey Energy calculations stamped by a Washington State licensed . engineer or architect Legal description Working drawings, stamped by a Washington State licensed architect, which include: • Site plan • Architectural drawings • Structural drawings • Mechanical drawings • Elevations • Civil drawings • Landscape plan Completed utility permit application (one for entire project) Six sets of civil drawings NOTE: See utility permit application and checklist for specific utility submittal requirements. RACK STORAGE Completed building permit application PI Assessor: Account Number • Two (2) sets of plans, which include: Building floor plan showing: • Entire space where racks will be located • Exit doors • Dimensions of all aisles Tenant space floor plan showing rack storage layout, aisles and exits. NOTE: Include dimensions of racks (height, width and length), aisles and exit ways on plan. n Structural calculations stamped by a Washington State licensed engineer (rack storage 8' and over). RESIDENTIAL NEW SINGLE - FAMILY DWELLINGS /ADDITIONS pi Completed building permit application (one for each structure) SUB,VIITTAL CHECKLIST Legal description Assessor Account Number Two sets (2) of working drawings, which include: • Site plan ---► (On plan, show closest hydrant location. • Foundation plan . Include access to building, showing • Floor plan width and length of access.) • Roof plan • Building elevations (all views) • Building cross - section • Structural framing plans Washington State Energy Code data in Completed utility permit application Li Six (6) sets of site plans showing utilities NOTE: Building site plan and utility site plan may be combined. See utility permit application and checklist for specific submittal requirements. Additional topographical and soils information may be required if unique site conditions. COMMERCIAL TENANT IMPROVEMENTS Completed building permit application (one for each structure or tenant) Assessor Account Number I I I Two (2) sets of construction plans, which include: Site plan Location of tenant space • Existing and proposed parking • Landscape plan (if applicable, i.e., change of use 7 Overall building plan • Tenant location • Use of adjacent (common wall) tenant • Overall dimensions of building or square footage '. Floor plan of proposed tenant space • Tenant space plan with use of each room labelled. • Exit doors, egress patterns. • New walls, existing wall, and walls to be demolished. Construction details • Cross sections showing wall construction and method of attachment for floor and ceiling. (__ Structural calculations stamped by a Washington State licensed engineer may be required if structural work is to be done (2 sets) NOTE: If any utility work is to be done, submit separate utility permit application and plans. REROOF n Completed building permit application (one for each structure) Assessor Account Number Il Narrative describing existing roof, material being removed, and material being installed. NOTE: A certification letter is required prior to final inspection and sign - off of the permit. ANTENNA/SATELLITE DISHES Completed building permit application Assessor Account Number Two (2) sets of plans, which include: Site Plan (showing building and location of antenna/satellite dish) — 1 Details antenna/satellite dish and method of attachment Structural calculations stamped by a Washington State licensed engineer may be;required RESIDENTIAL REMODELS Completed building permit application (one for each structure) Assessor Account Number Two (2) sets of working drawings, which include: • Site plan • Foundation plan • Floor plan • Roof plan • Building elevations (all views) • Building cross - section • Structural framing plans NOTE: If any utility work is to be done provide utility permit application and plans must be submitted. • REROOFS n Completed building permit application (one for each structure) • Assessor Account Number n Narrative describing existing roof, material being removed, and material being installed. NOTE: A certification letter is required prior to final inspection and sign oft of the permit. CITY OF TIiKWILA Permit No: 896 -0057 Address: 600 ANDOVER Pf+. E Suite: Tenant: HEATCON Type: B-BLDG Parcel #: 262304 -9100 * :4k k :. 4-k'k k 4 k•4'k'4'k k'4 k 4'4' :k k'k'4 Permit Conditions: 1. No changes will be made to the plans unless approved by the Architect or Engineer and the. Tukwi 1;,a Building Division. 2. Electrical permits :hl I be obt.ained the Washington State Division of .Lator and Industries'ad ~a1:.l electrical work w i l l be in_ypected by.'that agency (243'.=6610). All permit prction ✓and app plans shall be available at; :the job site to' the start of any con - structiorl document:. are . to be maintained and; avail- able unt;i *:'t i,na.l inspection approval is granted. 4. All stru,ctural welding ;hall beAorie by W.A.B.0.. certified welder's and special inspected' (UBC. - Sec. 3O6(a)5) S. !When*ecial inspection. is required either the owner, ar ~chi tact or engineer'_ shall- notify the Tukwila Building Divtsion 'of appointment of the : inspection agencies prior to the.s"'frst` bui l,ding inspect ion. Copies of all special inspect'ionreports shall be submitted to the Building Division in a timely. manner Report: shall contain a:idir'e:.s., prdject name x pe number. and ".type of. inspection being performed 6. The :pedal inspector, shall submit a filial signed report stating 'whether , the Work re,quiri.ng s.pecia.l inspection - was, totthe best of the inspector ..s knowledge; in conformance with `. ored plan= avid specit.1'.ations ar�.d ..the applicable workmanship provisions of the UBC. 7. All ;,'..con! traction to be done in conformance with approved plan ,'.an'd :requirements of the Uniform Building Code 01994 Edit,iuci.) as amended, Uniform Mechanical Code (1994 Edition)., and Washington State Energy Code (1994 E d i t i o n ) . i?',. Validity'., of Permit. The issuance of "a permi.t or approval of plans.,'sp:ecifications :and computations shall not be con- strued to be a:'per•mit far', or an approval of any violation of any of : th,e p r o v i s i o n s of the bu i l d i ng code Or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provision's: of t h i s code shall be val'id'. Status: ISSUED Applied: 02/23/1996 Issued: 03/19/1996 4 4 4 -4 44 '4 ' 4 k 'k k 4 '4 4* 4 4 4 4 4 'A '4 :4 4 4 '4 'k 4 -4 4 :4 '4 4 -A 4 4 4 4 '4 '4 4 ;4 '4 4 k :4 '4 4 ' 4 4 44 • *A****A*0****A CITY OF TVKNIi * IRANSIU Numb Payment Meth / Permit Parcel Site Addre Account Code 000/322.100 000/345.830 000/386.904 +++,4++*/ * ++ +^ + *++A.A.A4++*^*+*A+/,+h^A+++* A, NA lnNSMIT ***-4+A 4A 4 .x Oh+ 47*++A- 4 Alt A+4** er: 96003699 Amount: 107.21 O2/23/1 � :37 od: CHECK Notation: H[ATCON INC Init: KJP No: B96-0057 Type: B~UL0G BUILDING PEKMI[ No: 262304'9100 es: 600 ANDOVER Pk E Total Fees: 107.21 [his Payment 107.21 Tctal ALL Pmts: 107.21 Balance: .00 +++*+*+* Description BUDDING - NONkES PLAN CHECK - NDNHES STA\E BUILDING SURCHARGE Amount 62.25 40.46 4.5O GENERA 107.21 TOTAL 107.21 CHECK 107.21 CHANGE 0.00 2997A000 15:20 ' • •• • "' • • • • • • w • • • . . • , , • y, Project Name /4 C-( Address ‘00 AA/AM/. P g Retain cu?rent inspection schedule Needs shift inspection Approved without correction notice Approved i with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre-Fire: Permits: Authorized Signature City of Tukwila Fire Department TURWILA FIRE DEPARTMENT FINAL APPROVAL FORM . Permit No ■62.6 v 4: U. Date FINALAPP.FRM T.F.D. Form F.P. 85 John W. Rants, Mayor Thomas P. Keefe, Fire Chief Suite # Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 375-4404 • Fax (206) 575-4439 COMMENTS: y K. r \- Ad dress: , _ ` r r r led: 8 Requester: 7 Phone No.• ' \J • b ti Project:! l—MATC101. K. r Type of inspection: D' � / Date called: 5 _ 2 . cl G Ad dress: , _ ` pecial instructions: r r led: 8 Requester: 7 Phone No.• ' INSPECTION NO. I I arsTvitYX:;fr;: r 2 a: ,° : * 7 rvmt n'�Xr INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BIDING DIVISION 6300 Southcenter Blvd., #1;00, Tukwila, WA 98188 Approved per applicable codes. Corrections required prior to approval. , PERMIT NO. (206) 431 -3670 Date: 5 /D .46 $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: COMMENTS: ..... - Address: 10 5A eel iyor, • Date called: 5 _ g. _c i Special instructions: `, x... v.) Z Mted: sl i ) prn. Requester: ---r 1 Phone No.: • 1- 47 _ k-e, ("/ •,,, ' L ' h-t 3 ' / c . 'N ■7623e ri e,i In i tio, el 2-- ./ a/Pt.-GI =7 i- _P-4 ( /2,/4a1 • Project: Type of inspectiolis-, 1 1 / GuMit vs Address: ) d(off/ .. • Date called: 5 _ g. _c i Special instructions: `, x... v.) Z Mted: sl i ) prn. Requester: ---r 1 Phone No.: INS TION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Sobtficenter Blvd., #100, Tukwila, WA 9818 Inspector: D ate3 ,i 49... cf Approved per applicable codes. INSPECTION RECORD Retain a copy with permit PERMIT (206) 431-3670 Corrections required prior to approval. $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Project: i 1 Tc COMMENTS: AL- yr , k'S - - - t n_ * *(14' .--. l; N aF 1a ,.,\ENJ yr . - z2AoJ , ,.* -- /ZS k1E A -a,..' 6v X -x , S S , Ft(ki- o wrr8 A Pi #3rtAc..ASs0 s; t. FM i' E 2 , s,.rf AW 14E /n 2z . S;Yc.c,■ c- i.tri - f - )44l b34.i v, , (AC? comes-- `T oi. i Cr& lA t T ► e 450..ILA v. fa.-P L r 'ham j1` riN,Ar S'c'\ vvP N Yom. j11 1 ate Zr "11 rv. 66 tts i lcY / vW +sue' f ras - Dale Wanted: A F- A Pew,,, -t- � .t ate - )- ,. - FO it— S-ert cilk1 'STMA ,c.d 6 cox fe-Ack OF k'Gr -■ r•►CLs4L 1°M V �61l ►& k rt. 1 (,)1\k cv.1 hl-C 1 S ? eLltu 13G . W vrN-S .01 /1.... U Q 21 A, r1 A l 5 tw I Apr r-r c � 4 i t o rJ / To CA c— i b1 F d ,4 -434-dv4" capS SPr N Phone No.: f 6416 (1 1 A / O it Cs) t4 LA' V" Q aoK AO 1/4.-t_ c ,A— P. .." F -- 14, -1.0 1a G.Wil a, . Project: i 1 Tc Type of Inspection: wesimt 'Tz n) Address: Coe- A. P. Dele ('anted: i Q 2-4 Special Instructions: Dale Wanted: Phone No.: CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 ❑ Approved per applicable codes. INSPECTION RECORD Retain a copy with permit PERMR N0. (206) 431 -3670 ❑ Corrections required prior to approval. I Inspector: Dale: -2f _ ; ❑ $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Reoept No.: Dale: Jan 28, 1997 TIM BOUSHEY 600 ANDOVER PK E TUKWILA WA 98188 RE: HEATCON Dear Permit Holder: Our records indicate that on Nov 06, 1996, one hundred and eighty days will have passed with no inspections having been called for under Tukwila Building Permit Number`}B96 =0057. Unless you call for an inspection, or obtain a written extension from the Tukwila Building Official prior to that date, your above referenced permit will become null and void on Nov 06, 1996. If your project has been completed please call for final. If you are actively working on it please notify our office. If you have any questions or need further information to obtain an extension on your permit, please call the Tukwila Building Divison at 431 -3670. Sincerely, City of Tukwila Department of Community Development Steve Lancaster, Director g yi ry Kelcie J. Peterson Permit Coordinator Department of Community Development Frf FILE COPY John W. Rants, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • (206) 431-3670 • Fax (206) 431-3665 : ?rrtn.•.r. Dear Sir: c City of Tukwila Fire Department Thomas P. Keefe, Fire Chief Fire Department Review Control #B96 -0057 (512.5) Re: Heatcon, Inc. - 600 Andover Park East March 8, 1996 The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. Sprinkler protection shall be extended to all areas where required, including all enclosed areas, below obstructions and under overhangs greater than four feet wide. (NFPA 13 -4- 4.1.3.2.1) Maintain hose station coverage per City Ordinance #1742 and N.F.P.A. 14. Addition /relocation of walls or partitions may require relocating and /or adding hose stations. Hose racks must remain unobstructed to allow the rack to swing freely. (UFC 1001.7.3) 2. All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recognized by The City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1742) 3. The total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 3000 sq. ft. of area. The extinguisher(s) should be John W. Rants, Mayor Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone (206) 575.4404 • Fax (206) 5754439 City of Tukwila Page number 2 Fire Department Thomas P. Keefe, Fire Chief of the "All Purpose" (2A, 10B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (NFPA 10, 3 -1.1) Extinguishers shall be installed on the hangers or in the brackets supplied, mounted in cabinets, or set on shelves (NFPA 10, 1 -6.9), and shall be installed so that the top of the extinguisher is not more than 5 feet above the floor. (NFPA 10, 1 -6.9) Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be identified with a sign stating, "Fire Extinguisher ", with an arrow pointing to the unit. (NFPA 10, 1 -6.3) (UFC Standard 10 -1) Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5) 4. No point in a sprinklered building may be more than 200 feet from an exit, measured along the path of travel. (UBC 1003.4) Obstructions, including storage, shall not be placed in the required width of an exit, except projections as permitted by the Building Code. Exits shall not be obstructed in any manner and shall remain free of any material or matter where its presence would obstruct or render the exit hazardous. (UFC 1203) 5. Storage under exterior or interior stairways shall not be permitted unless such space is protected on the enclosed side by one hour fire - resistive construction and sprinklered where required. (UFC 1210.3) 6. When two or more exits from a story are required, exit signs shall be installed at the required exits and where otherwise necessary to clearly indicate the direction of egress. (UBC 1013.1) John W. Rants, Mayor Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 57.5-4404 • Fax (206) 5754439 City of Tukwila Page number 3 Fire Department 7. Exits shall not pass through kitchens, storerooms, restrooms, closets or spaces used for similar purposes. (UBC 1003.5) 8. Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 1207.3) Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 9. Storage may not be closer than 36 inches in all directions to ceiling -hung "Space or Unit" heaters. (UFC 1109.2) 10. Storage may not be closer than 18 inches below sprinkler heads. (NFPA 13, 4 -2.5 and NFPA 231.5 -1) Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Yours truly, The Tukwila Fire Prevention Bureau cc: TFD file ncd John W. Rants, Mayor Thomas P. Keefe, Fire Chief Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 5754439 STATE OF WASHINGTON ) COUNTY OF KING ss. AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION I hNlUrl S. Ol.A.SH4` , states as follows: 1. I have made application for a building permit from the City of Tukwila, Washington. 2. I understand that state law requires that all building construction contractors be registered with the State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the Revised Code of Washington, a copy of which is printed on the reverse side of this Affidavit. I have read or am familiar with RCW 18.27.090. 3. I understand that prior to issuance of a building permit for work which is to be done by any contractor, the City of Tukwila must verify either that the contractor is registered by the State of Washington, or that one of the exemptions stated under RCW 18.27.090 applies. 4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby attest that after reading the exemptions from the registration requirement of RCW 18.27.090, I consider the work authorized under this building permit to be exempt under No. 13 , and will therefore not be performed by a registered • contractor. I understand that I may be waiving certain rights that I might otherwise have under state law in any decision to engage an unregistered contractor to perform construction work. p2A4_ APPLICAN Signed and sworn to before me this /f** day of L- 7114,telt.._ , 19 94 . NOTARY�UBLIC in and for the State of Washings residing at County. My commission expires: 6-f' /' k, . 18.27.090 Exemptions. This ch4..;r shall not apply to: 1. An authorized representative of the United States Government, the State of Washington, or any incorporated city, town, county, township, irrigation district, reclamation district, or other municipal or political corporation or subdivision of this state; 2. Officers of a court when they are acting within the scope of their office; 3. Public utilities operating under the regulations of the utilities and transportation commission in construction, maintenance, or development work incidental to their own business; 4. Any construction, repair, or operation incidental to the discovering or producing of petroleum or gas, or the drilling, testing, abandoning, or other operation of any petroleum or gas well or any surface or underground mine or mineral deposit when performed by an owner or lessee; 5. The sale or installation of any finished products, materials, or articles of merchandise which are not actually fabricated into and do not become a permanent fixed part of a structure; 6. Any construction, alteration, improvement, or repair of personal property, except this chapter shall apply to all mobile/manufactured housing. A mobile/manufactured home may be installed, set up, or repaired by the registered or legal owner, by a contractor licensed under this chapter, or by a mobile /manufactured home retail dealer or manufacturer licensed under chapter 46.70 RCW; 7. Any construction, alteration, improvement, or repair carried on within the limits and boundaries of any site or reservation under the legal jurisdiction of the federal government; 8. Any person who only furnished materials, supplies, or equipment without fabricating them into, or consuming them in the performance of, the work of the contractor; 9. Any work or operation on one undertaking or project by one or more contracts, the aggregate contract price of which for labor and materials and all other items is less than $500, such work, or operations being considered as of a casual, minor, or inconsequential nature. The exemption prescribed in this subsection does not apply in any instance wherein the work or construction is only a part of a larger or major operation, whether undertaken by the same or a different contractor, or in which a division of the operation is made into contracts of amounts less than $500 for the purpose of evasion of this chapter or otherwise. The exemption prescribed in this subsection does not apply to a person who advertises or puts out any sign or card or other device which might indicate to the public that he is a contractor, or that he is qualified to engage in the business of contractor; 10. Any construction or operation incidental to the construction and repair of irrigation and drainage ditches of regularly constituted irrigation districts or reclamation districts; or to farming, dairying, agriculture, viticulture, horticulture, or stock or poultry raising; or to clearing or other work upon land in rural districts for fire prevention purposes; except when any of the above work is performed by a registered contractor; 11. An owner who contracts for a project with a registered contractor; 12. Any person working on his own property, whether occupied by him or not, and any person working on his residence, whether owned by him or not but this exemption shall not apply to any person otherwise covered by this chapter who constructs an improvement on his own property with the intention and for the purpose of selling the improved property; 13. Owners of commercial properties who use their own employees to do maintenance, repair, and alteration work in or upon their own properties; 14. A licensed architect or civil or professional engineer acting solely in his professional capacity, an electrician licensed under the laws of the state of Washington, or a plumber licensed under the laws of the state of Washington while operating within the boundaries of such political subdivision. The exemption provided in this subsection is applicable only when the licensee is operating within the scope of his license; 15. Any person who engages in the activities herein regulated as an employee of a registered contractor with wages as his sole compensation; N 0 16. Contractors on highway pr who have been prequalified as required b ( chdpter 13 of the Laws of 1961, RCW 47.28.07.Q with the department of transportation to perform highwjiy construction, reconstruction, or maintenance.tivork. : .. .:' :f,t.:fire. i.iui'v._J` + ":t4la xxw.ni `t t'rem, .% «nix xww.. .....�.. w • CAL.FIN E--L ENGINEERING , I NC . CONSULTING ENGINEERS VAICOUVEI, MA afk0 ;II-574-1127 STRUCTURAL CALCULATIONS : CLIENT: PROJECT: LOCATIOI: PROJECT Mo, DATE: to --Q9 Q5c..00.GL.T C t7 -.XISTIN MM s.b.4 114M 121a �w EXPIRES 4 1 1Z.e. ' '0a-a c-gt , 1 1- 4G4-44D 0'D t G 8G THE ATTACHED CALCULATIONS HAVE EITHER BEEN COMPLETED BY MYSELF AID/OR UIDER MY DIRECT SUPERVISION BY A STAFF MEIBER(S). GA RECEIVED CITY OF TUKWILA FEB 2 3 1996 PERMIT CENTER El raa Li • 4 CONSULTING ENGINEERS U VANCOUVER, WA. Z ki (206) 574-1127 • • t i ; 4 ..C Pp Drilic psis4cs) CLIENT: lArmATC•e> I a vt JOB: M41-4 I 1-4r RaNei ay.( DESIGNER: V,044..• . CHECK: , I i • I 'Criaw. " 1 I 1 s I i i i I I ‘F.-t It rfirt ; 1 I i i 1 + 1 ! .4.. 1 i ! I i .f.... I i , I I , 1 77C"--7.6 ! -1- 1. • i • • : , i I 1 • --3 - %Ye," FStv1:7 .6 SHEET: C■ "FIZeni4:r t DATE: i 1 i : 1 i t I ■• 'x - 1:.. i'< cv . i • . t Ir --...• . • • :-..... , . , -b- . ' \--r---rr : . ........... : • • . TeP Cgre.-4,4-V . 0 E • .. CONSULTING ENGINEERS 0 VANCOUVER, WA. Z Ail (206) 574-1127 CLIENT: kaNTC2V JO's mseeAr-41 P$,. .. ge_Y I PY .. DATE: IV 7 fr DESIGNER: (.51 I 4 . srvIAL4.„ v41 11 x2 M 1.41g-v,e. 1 I I tptilsi.a4 igra .... Igor! • ' 1 ' I IP a 4 Kr gr . .. ! . i ( 1 4%. — le i• 10 .4) I . , ! i siv.,4:c440.4.! la...kucefr4A...g.go !AV...V.A..... i•nit> J.2 ! ..i... i . . , Tiseit IS ;Ae:a..i.r4t:>! 0;t--1. , i 1 rs44144 • ; 4arirC4•11- air (QP i e ' 1 - kE - 1. .2 ! '* •i 11 7 4 . 6 ; • ! M'aA4 a 1 > l F 1 s ti:N , :t-4 • i .1 .4 . • M t . . 1 ! ' t ! ; r ' t 4 C: . C; 1 AI? eo 14. C, 1 . 1 . 4> : i4a4TCoe: r c ! i I) , ...i 2) . I 1 . . . . . : 1 i 1 ' ' , , ■ i i :. ! • : ; ' : -1: ' : 1 :1 • 1- : tr : f - - ' • : ' NOTICE OF DRAWING nEVIENT 1h" compliande With a local: Ordinance;le Plan ! i ' - 1 ' .. .... • .review of lateral „and .vertical load transfer has . . . ..... . ' been completed by EL Engineering to assure that the structure meets iptent•oldur•oalcUlatiens,: ! i•-• i - * dated: .. •s• - C , "'"" . . 4 ." No other warranty is given/implied or expressed by this Engineer even if structural revisions have been made. Review 1p for confirroatiOn purposes Date: ' -.4:14° zed Original SignatureOnly) .11151r— ' 7Jt iSei 14S . • I 1 III wa L 0 F., CONSULTING ENGINEERS U VANCOUVER, WA. z ga3 (206) 574-1127 CLIENT, . JOB: metais4 IN _ 12E•1 eV%, DATE: 42.54 DESIGNEItt - -[ 1 +41.G SHEET: -- 1 — 0124C.13$ . , i i 1 , 1 I .•• • - . . . - ' ... . !...14.4 .. t . i.gd I BO% L . - - cido.ii i • sm, 1 4> i , . .,• (ace) 1 2oi m2.1, 22•; --- --F ; : 1 • I . ! CP, .CO a , : 0 a 0 6 2 • C:r , c, • I e. I 1 • •i . . . • . . i • i • - • ----- i - . 1 — , r . . 1. .. . : ■ i : . 1 i I :: I ! i i f : :7 • : . ' . .. 1 . 1E1;2 OAC.!• t i ; 1 . . 7 t 1 i ; i kag/aCelki I .T L-.. 1 ...• S . I • 1 • - - .,, . . — T2,4_1 .4. • . ,... .... C-.126S bUt,e,4.,1 i44, i i IFvZST : ■- : ; . . : ...... ...•• • ! 'I hello ksAINERS ... . - • , • i ; 1 1' .• 1 ! + 7 7 77; • 777 1.' 77 ' 7 7 1.7. • • .• . • i . . ! T. . i ! i ! i i 1 : • . I f•- • : i; . ...". : . ., .. , •• • . 1 ,---- ..i • .. - t- - ; i . . • i • ,• ! • - , : , i . . . , 1 . . s • - i - i i .• , . 17- , : ...... . .. .. . • • . 1. , . , . , . : 4 i i ■ : i i ■ : ! S ‘4 I T CI121 1 • i ,.. . • .. ... i . .. . . .1 .. . .; .. .... . ..... ..... ..... • • • ...; ... i i • 4.. ..; .. 1. ■ I ! i I • 1 i i : • : • i . ... 1 1 ,. . 9 4. . I , , , i I ! : 't 1 ? 1 1 i 4 .... ... . , . , . , . . .. . .. . , . .. .. .. . 4.. .. . 1 . I f r 1 . • , :. : . i I I . . . I ■ i ■ i ..- . 1.. - 1 .. ; ... . .... 1 • 1 . . h• • • t . ... i i, 4 . • • " '. t ? • . . . • ! I I I t t I i t , t .. . t t . 1 . ,. t • ' 1 • • t 1 • I • • • • " .• • • ! • 't ' 1' • 1 1 . .. ■ . t i ! I t t t 1 i I . i i I • .. . • . , . . i • . i i • i .. • , t ,,, , I i i t i •:. • , " t . I ; . • ■ • , .. .....• ... t .. i • . . . 1 . , . ! i I . t ' ' ; MEMBER MEMBER 1 2 3 4 5 6 7 MEMBER MEMBER 1 2 3 4 5 6 7 MEMBER MEMBER 1 2 3 4 5 6 7 JOB TITLE: HEATCON 1 2 5 0 9 0 0 STRUCTURAL INPUT DATA UNITS: LBS, INCHES, RADIANS NUMBER OF DEGREES OF FREEDOM = 16 NUMBER OF MEMBERS = 7 MODULUS OF ELASTICITY = 2.9E +07 END DEGREES OF FREEDOM HORIZ -START VERT -START 0 0 3 6 0 10 0 0 ANALYSIS OF PLANE FRAMES 01 -23 -1996 LENGTHS HORIZONTAL 0 134 138.5 0 135 0 0 PROPERTIES AREA SHEAR AREA MOM- INERTIA 4.54 4.54 16.6 1.05 1.05 11.1 1.05 1.05 11.1 4.54 4.54 16.6 1.05 1.05 11.1 4.54 4.54 16.6 4.54 4.54 16.6 VERTICAL 120 0 0 120 0 120 120 ROT -START 1 4 7 8 11 12 16 HORIZ -END 2 5 9 5 13 9 13 SECT MOD -TOP 6.64 2.76 2.76 6.64 2.76 6.64 6.64 VERT -END 3 6 10 6 14 10 14 ROT -END 4 7 11 7 15 11 15 SECT MOD -BOT 6.64 2.76 2.76 6.64 2.76 6.64 6.64 n,. Mt1 t ia'.e 57 >6.. i:.h'a.f+lk uCxa Cr:J T -, ?ft JOB TITLE: HEATCON 2 STRUCTURAL INPUT DATA UNITS: LBS, INCHES, RADIANS NUMBER OF DEGREES OF FREEDOM = 22 NUMBER OF MEMBERS = 11 MODULUS OF ELASTICITY = 2.9E +07 ANALYSIS OF PLANE FRAMES 01 -23 -1996 n .�.aw.r,.ex++n...w n..+,�.. MEMBER END DEGREES OF FREEDOM MEMBER HORIZ -START VERT -START ROT -START HORIZ -END VERT -END ROT -END 1 0 0 1 17 18 19 2 2 3 4 5 6 7 3 5 6 7 9 10 11 4 0 0 8 5 6 7 5 9 10 11 13 14 15 6 0 0 12 9 10 11 7 0 0 16 20 21 22 8 17 18 19 5 6 7 9 9 10 11 20 21 22 10 17 18 19 2 3 4 11 13 14 15 20 21 22 MEMBER LENGTHS MEMBER HORIZONTAL VERTICAL 1 0 90 2 134 0 3 138.5 0 4 0 120 5 135 0 6 0 120 7 0 90 8 134 30 9 135 -30 10 134 30 11 0 -30 MEMBER PROPERTIES MEMBER AREA SHEAR AREA MOM- INERTIA SECT MOD -TOP SECT MOD -BOT 1 4.54 4.54 16.6 6.64 6.64 2 1.05 1.05 11.1 2.76 2.76 3 1.05 1.05 11.1 2.76 2.76 4 4.54 4.54 16.6 6.64 6.64 5 1.05 1.05 11.1 2.76 2.76 6 4.54 4.54 16.6 6.64 6.64 7 4.54 4.54 16.6 6.64 6.64 8 1.94 1.94 3.04 1.05 1.05 9 1.94 1.94 3.04 1.05 1.05 10 4.54 4.54 16.6 6.64 6.64 11 4.54 4.54 16.6 6.64 6.64 8 9 10 11 12 13 14 15 16 MEMBER AXIAL 1 STA 1359.825 1 END 1359.825 2 STA 833.8438 2 END 833.8438 3 STA 2043.969 3 END 2043.969 4 STA - 448.1605 4 END - 448.1605 5 STA 3258.75 5 END 3258.75 6 STA 447.7631 6 END 447.7631 7 STA - 1359.428 7 END - 1359.428 LOAD CASE 2 LATERAL NO BRACES - 2ND RUN JOINT LOADS AND MOMENTS ,DOF NUMBER LOAD VALUE 13 4100 1 2 1.996721 3 4 5 2.00039 6 7 2.009687 2.024135 SHEAR 833.8682 - 833.8682 - 1359.825 1359.825 - 911.6648 911.6648 1210.119 - 1210.119 - 1359.428 1359.428 1214.824 - 1214.824 841.2308 - 841.2308 DOF NUMBER HORIZ- DISPLACEMENT VERT- DISPLACEMENT ROTATION 1.239397E -03 - 4.084708E -04 4.081085E -04 - 1.239035E -03 2.078072E -02 8.309078E -03 4.580942E -03 2.267994E -02 4.611425E -03 2.278078E -02 8.463982E -03 2.104574E -02 MOMENT STRESS -TOP STRESS -BOT - .015625 299.5234 299.5187 - 100064.2 - 14770.38 100064.2 -35461 82152.42 30559.51 63061.94 - 20901.89 63203.64 24846.51 .0078125 - 98.71494 - 145214.3 - 21968.34 82575.19 - 26814.97 100947.6 39678.79 - 3.515625E -02 98.63152 98.62093 - 145778.8 - 21856.01 22053.27 - .046875 - 299.4264 - 299.4405 - 100947.7 - 15502.39 14903.53 15369.43 37049.27 - 28971.23 ✓ 24795.16 - 20953.23 ✓ - 98.71259 21770.91 33022.12 le - 33471.65 yMPOP SE:T 5 DOF NUMBER 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 MEMBER AXIAL 1 STA 1111.996 1 END 1111.996 2 STA - 1793.188 2 END - 1793.188 3 STA 1785.781 3 END 1785.781 4 STA - 493.4974 4 END - 493.4974 5 STA 7883.031 5 END 7883.031 6 STA 1121.046 6 END 1121.046 7 STA - 1739.551 7 END - 1739.551 8 STA 3004.895 8 END 3004.895 9 STA - 5558.997 9 END - 5558.997 10 STA - 1713.347 10 END - 1713.347 11 STA- 329.2852 11 END - 329.2852 1.232637 1.224746 1.232868 1.267817 1.216959 1.218379 LOAD CASE 1 LATERAL WITH BRACES - SHT 3 JOINT LOADS AND MOMENTS DOF NUMBER LOAD VALUE 13 4100 HORIZ- DISPLACEMENT VERT - DISPLACEMENT ROTATION 1.651535E -02 SHEAR 1074.768 - 1074.768 - 167.867 167.867 - 618.5173 618.5173 711.0458 - 711.0458 - 329.2846 329.2846 716.0762 - 716.0762 1598.182 - 1598.182 - 294.7804 294.7804 - 209.3342 209.3342 - 555.5772 555.5772 - 3782.992 3782.992 - 7.744645E -02 - 4.497926E -04 1.021764E -03 - 1.264151E -03 7.601372E -04 - 1.18912E -03 - 2.663928E -03 3.102928E -03 1.373761E -02 3.120365E -03 1.383027E -02 7.475209E -05 1.798901E -02 7.473372E -03 4.543566E -03 MOMENT STRESS -TOP STRESS -BOT - .0078125 244.9343 244.9319 - 96729.09 - 14322.7 14812.57 - 2606.272 - 763.4965 - 2652.099 25100.45 7386.568 - 10802.16 42791.79 - 13803.53 17205.02 42872.85 17234.38 - 13832.9 2.734375E -02 - 108.704 - 108.6957 - 85325.53 - 12958.93 12741.53 29488.8 - 3176.7 18192 14964.61 12929.61 2085.687 .015625 246.924 246.9287 - 85929.16 - 12694.21 13188.07 - .0078125 - 383.1599 - 383.1622 - 143836.4 - 22045.27 21278.95 23045.1 - 20398.8 23496.63 17433.3 18152.06 - 15054.23 13567.47 - 15786.87 10055.94 15382.02 11784.08 -17515 73684.01 - 11474.38 10719.6 2606.277 15.12253 - 769.9008 - 14964.58 2181.172 -2326.231 128454.3 19273 - 19418.06 El r _ 5 MI5 VANCOUVER, WASHIN q •.N), .... G;l..,� ,r • • .• wns o; y , ;.. 4 . , STRUCTURAL ENGINEE 1-tV.6. c c.©1 -4 10.ZS • Set 2 iMST .D MANU 1 I NC M a 4 t rig TZEv rEW rv.TR: MAT�rz at... L.av� t "AS $U t I.•T " Cc:42 40c S 11 0 Z gc Gri 0 F. CONSULTING ENGINEERS z VANCOUVER, WA. ill ( 206) 574 -1127 CtIENT. �UMST JOSS M 3 - SMEETt ._ DATE, DESIGNER: AA- • CHECK: _ .. I YD" pWC% ∎ TkO._*+r ±lr •n `';ItIu 4N1 - Tr:! 4,4;;%a " .. 4 i c. . WAS ... ........:...... v oF .. GwD qv F g psi T.L.. tfil G'SP tcp W + td �+ �+ h�i I ,14014 1J1Lv Z lox 4' 05g w Iax S � Ito Z• I o at cd ;a ;a 6 0 4 CONSULTING ENGINEERS VANCOUVER, WA. z ili (206) 574-1127 I I ..1, ... „.... 1 C...k4c. 1 G g00AZ ;4 141. 6 ■ pi— in 1 , -- i• - 1 . i - 1 "”" 1 T - 1 - R • — 1 ‘ 4 rPel 4 ":- i _, 4 1 I ! TIZ‘f .! C■s#444ere 1 c- . 45 ,, r•st 1 i-4 teo I ; 1 f ■ 1 . . I i I _ ; , . . , i FOSS 1■401 t-r.6..e,* 41"sc )% 3" , ! 1 1 . ..5, s 1 • 40 : ! ;- -;-• 1 • : , 1 ; i : 5 a . ,,• 4 : . • 4 , . i- , i .i-- i 1 1 ! tv$ (120 c? 7. 41.1131 • ' : : i :I, f,8 :' i : I . . . ; . I ' . • 14-D ! : , I t I f . 1: - .e. 1• ! , " I .."--- • i i ' fi,:„....! 2)i.4, . ... i .. ......„, . =, zi 0 ,c,„. • : : • .. ..; - i • ' 7 I ' • ! : : T fotr 1 . --i... i . i . . : — „ • 4.-1144.., x .2 x 14 cv".■ . ; e,04 • ; ; 1 1 - ; ! Sz , t 7 gS:r. . i i .!: ; !' ': : ' ! : 1 . 1 , 11 *.! . 0....Mi " ' ; , • i : ! , ; , )40 ."‘ Yatt. 1 1 iC4414..1•01easa . Y.... ; vi-g. licr7 • : LW . 14..'-.. ..i:e7 419:--i. CIG.5) A 12: vi vs ...- : 24 Ll-a ,V...lie t4z4r. •ZteN 14. , eF*. zeyi : ' : 1 1 : : t : ., , .1.114 • , . 1 ,..4'.4374 *; e..c• - 7 Ic;? is 1 *.q...: J . . : : • , , , : „ • . r,g4 * II .i3 ' • • ' . : 1 ViiwIT- se.. Z d 11 , . . . . , Pck 4 ti. 13 o• 4.44 a '',..-3 e4 • ' . • - i : P ic...ix :$. 12. . . . • CLIEN XAASTP.A .101, I DATE1. DESIGNER: 01 - 4 . • CHECK8.. cp.144.6 c=ic. c-42.-LG Si4412 . •ob.e?: I*. .ii.'2.": .1714.44 . : ft?'-e. tg..44. 4 C:1460Viz !l4'47e07t); , i Co) • ;a wE CONSULTING ENGINEERS VANCOUVER, WA. z kg (206) 574-1127 . • 1 1.4 c4 NAI.11U • 2+1 4 (4.. M i i • 1 i ; ■ • i • 4 , 1 rPriantk Is S A. mwera. Nor. r2..x 2. taci,T • CLIEN1._.34MbileftV MANS4. JOBs t—i*....itaca •••1.•••• • • I : acac.it.4e2 14,135 Mina . WC, • • , • • • pp • . . STANIN.* SHEET: 5 DATE, 10-219-0 DESIGNER% 514-1, • CHECK, 1 • ' ' i i t I I % ' • , , <7 '`' ..I.• , : • • ■ . ■ t • . 4 • . • . . . . . , . ,-. 4 • . . . . I II Z,o5 10.0 III . 10•0 5111 IC. v4 ••• 1 (0 4 11 16 "I • rp7- P•C•1)(0Zo)W P • . . . . )46.2( Q24 44 balocr 2.2 (.435 TiamQc.N. , . . . . Pm TeLgre.P ■0/731/e RE1310Z5 TRAP NI-L 1RIZ 10, MAT LL rt.‘"Ne PW‘S ogrAlirs Im o E og cia ;a 0 E, CONSULTING ENGINEERS Q VANCOUVER, WA. Z ill (206) 5744127 CLIENT: ..,0a4MSIXESNP JOB: DESIGNER: riA-tt' • ME Wa No I SHEET: 4 DATE: 1 )" . te CHECK: • . • • : ! ! 1 • i 1 ! ! ! • t . • - i - • l • t" , t r 1 , ; I : ••••• ; •I'ii I ; i 1 . I ; ; . • I 1 I I • .i., . i - i . i f I I . ik440 sr...0 ! r ! t 4 i i I jr I I ' i • H. 1 .. ' . ..4 i r :0 1 4° 4 40 1. 41 4/ 0 • i . 4 S ! 12 I ..s, IR r-L3i : ••• ; I , . ; I . ; ± I , t ; • I 1 1 ; • . ., . i ..- - . 1 Cl • e4 t. POs'r — L"TA.g.0 . .:: ....].........i.. .... ..l.....„..,' ................. ; ; : I ; 4q , AiSar .. ES a..c..4.. , F1.11 • • 1 , •1. • -V ui 1 1 1 1 Xra. ' = 24I . 'SC., toeiVP -H- i ; I I X 4 •33I.44: ; TROSZ140:aiLik rgehaift ' : ; • t "t; ; ; "; • 1 ; 1 11...,42 i . ! . . .. , . • Oxis-r • , t• : 0 . it—lt * c 11( +C it 23M 'Me=11•2::• 1 z o ••7 ip R 2.o5 (44) ( 23) ( two) rAZI•les.(5) 3.4 • ANSG C RiEY VOW , w. (144)4.1.11ar 7.% IA x :4. at I 27, 3.46/1.ty3 4.12. 61....41. 1 1 i : 1 : ; I ' - - I I ; , I 1 1 1 I I . . ., 1 , 1 i , , . ■ 1. ar...s. 1 ie. 1 ..1 i 1 i . 4 . 1 i ■ , . i ! • : i , , 1 , t ....1.• 1 1 • i ..- • ••i • -1- :. , i. i T.4 ACV v.. esier.'‘ ' i I i ! i 1 I. .., . 1 • ; • I I 1 . . .. .. . . . I. I I L .. 1 1 2.* i Z. 3-1 ia 140.4 k 1 i i . , -, 1 i , : 1 1- t • f - i i k • 0. Ica : ! . I i , I , • 1 1 .1 . 1 i t t • t i 1 • - t . f • r i i i : 14.1.-• A..• i sr if.t, ', : 1 : , ! 4 . r ! , 1 • • . . . .• : : ! r ... 2.. - it,(148., a 2-cri: , ...• • . i ....t... .;..._... ... r - : 4 ••• t .4. • : . : . .. . il , E. = ;a cola 0 F. CONSULTING ENGINEERS VANCOUVER, WA. II; ( 206) 574-1127 . • .. • • ; • .: 1 • 4 . 1 , i . I • I - • - t . • •• •- ; • i ii I x 'VI i ; 3■ 7- I .1, ikiz ., .1 i : . ; : , . r - i • • ."......• 4 ; . • • . I , ., . : : . • -- 4 • r - • i . . r • : ; . : . 4-. ; • -±. i : . . . : ■ i i : : : • I i 1 ! i I . , .:-... : : • 1 Pit4 -7 pet-i. 1 : 7 t . 1 I : i . . : 7 . ..• " ! i ; 1 i iL •O• ; i.o(ii-ie5) 4- • , ... ....... •••.• .. . , . . : . : • . .• . : : . • • • : . . • • . . , : . , . . : : . .....4. .... i. 5-- C•••4 e'l< : . ' .• : . ... : . . : I . Try ).c4-,x 'cop, 4.1=1-4 ruNca-c .; • - • tAelfg FA, • CLIENT. Est-imisins"P JOBs DESIGNER: Palm M. N. I • SHEET: 6 DATE: CHECK! I understand that the Plan Check approvals are sub.ject to errors and omissions and approval of plans does not :aul'oo.,-lzo '1-..-a ,,,,.olation of any i acc..,pted code or ordii,.E.•'-:., !"-:ecelpt of con- i tractor' s co of approv- 6 o.,..,ns. act((ovyledged. 1 . • ------_ 1 By Date _ aPIMI> 11-14 oft SE: OR tlif EcTRIctm" c\r „ Lut oloG r sS ° - '197.30' ATct oLJJ Ftcon 540 -.=• 3.D.0 S F \\• At HE.LZA-I f ;100 SF DFFICE. I , Zo0 SF , _,To5.5G e.„ itk11.1411 orAL,L 7400 s.r •••AnEl-IOUSE. I 6.f MeV-AI-WE 4TOry.4ff... f_97. 00' ADDFWY) LOO Al-COVE.F) rAnh AT IIThI LEVE,LOPMELIT rt,\LI ALL • 1".g.0 `B fAkr,oAD EA6E_ME-LIT N.6-00 3840 V 13 rHAN6E/1 •ITL6 To ,iftMad If- z'-9.'a arD DEt=1:.,1 • CA I ixt_157)1AL FAH) =kir \ Cy GM:LA/MEI-0_15E, Ph E: LT t r.14 EXIST. 317‘LLO (,o0 ,t4icovE?) rW EA6T L 6 AL IDE •••1 wt.*. *warn a ,a or imieloo• tee switill4,4::. *Pardo INF* • *AL*. - • . I • " • ---,'-:^ ,, 4 • • • • •=4:1 111••••••le :raw wit 'Mimi 11.1* ; anomie for Rim 11114 VIP. I I I 00 *a Mt - , lierit ammo as •••••••1••• Ono •••••••■•■ loot um' .4 wit me • 4.411•••••• oF •••• - ION/hatophar air was N Wive' • ..........., Op* iliaaa a 0.1010•• • • woo* a W • aro.. ••••••4IF di*. • ••••••••••t *oar irs to 11•0••• ,,,,,,......-ft••••00 lill . s . . .. , . :,••••4 \\PO OA - % .1,. ,,,a \s •0•\ PERMIT CENTER RECEIVED CITY OF - MANILA FEB 2 3 1996 FILE COPY I understand that th P. Cock .4provals are subject to errors cnct - ,r1 approval at plans does not authzrit--1 cf any adopt cca, or ordIna: t.ontractors copy of .0 plc • C-( '6.cf ..... — ... permil No. ..... 222'2_ ...... ......... p• I 3 NEATc.v.1 11.11WILA 5 rra.. rt44 mf=6, rs THOMAS A SCONZO /4.0at 12am AVE , MELVA. AA WOE /10.4.3.103 A GC OF RECENED alY Of 1 UKNOU 0C1 1 9 1984 BUILDINO of" Cc-TOOC-P) 11,1984 14 ELT TI I I CAMPO}... 19.A.Kikt ■ ----111 r Ex.t}rilACA ebM ExI'rIiJG. 5140 l'..00}1 JTUP it a.. 1.11.19E.P.5. as. t-v4Z2... exaSTI LK. vrAi..0 ENc GiOcrt. &, a • • X1 j; t& - Ad 4 EX.i i.16. .M AY) I V N- E-X I ST I LI if C., LECx-AP_. oF NI G7_2_ OF NEW MEZZ AT/0/4 (A\ N N :7Y NC, •kir- NEW tfrAR FULL HT. exi-yr - 1" u.r1. i2ooc • tr OH CI4AnI6at, TITLE_ - To f/EA7raii AMU, LocA77od ilEz74 *a_ MAPH C- - C ix z $ 77.1TAIL ?ALL .,CALL , 4 ‘ 4 1 -0 j HEATcok/ TII 1I HS1 - r.crA THOMAS A. SCONZO /aaat MO. ANL /1111LLINUIL Yak sMICII/30///4/1.1217. RECEIVED CITY OF TUKWILA FEB 2 3 196 PERMIT CENTER R J : 7AR RECEIVED OTT Of 1USON1LA 0011 1984 BUILDING DEM T2 VA IL: '0-1 00 BM GRATING L 35435 - x0.5" TYP. REAR Afik TR f wVJ+e C 4 7 O IT 1.34 000' 13A 5110' il If I� 1.125' PWD DECK: FASTEN PWD TO SUPPORTS WITH *12- 24x2.50 HEADER TEKS SELF DRILLING SCREWS • 6.00 O.C. TYP. 0 54.00' 3.00 - x3.00 - x025' TYP. 1 ff5 gepo OLD 346' 4.00" FRONT SIDE e SIDE BASE PLATES 5625 FOR 050 "x375 CONCRETE ANCHORS 050" FLAT WELD 3/16" CORNER BASE PLATES 5.00 - x9.00 - x0.50' FLAT OLD 346' WELD 3/16' NOTICE OF DRAWING REVIEW In compliance with a local ordinance, a plan review of lateral and vertical load transfer has been completed by E -L Engineering to assure that the structure meets the intent of our calculations, dated: • _G 9G . No other warranty is given /implied or expressed by this Engineer n if structural revisions have been made. ew is for confirmation purposes. I-BEAM 5.00414.00"x0.50" , Date. - 7 - 476 Certified En -� (Autheriz•. • riginal Signature Only) 05625" FOR O.5 WC GRADE 8 BOLT 127 "x8.50 -x GA. ROL FORMED JO 28.43' C.C. "x8 "x050" ANGLE 21L TYP. CITY OFETJ5 //5 FEB 2 3 1tyf; PERMIT CENTER STRUCTURAL STEEL AND MISCELLANEOUS IRON I. ALL STEEL SHALL CONFORM TO AST.A.36.70 AND TO UBC 27.1. 2. STEEL TUBE SHALL BE ASTM A500. FY -46kai GRADE B. 3. PIPE. WHERE INDICATED. MAY BE A53. GRADE B FOR STRUCTURAL USE z fY