HomeMy WebLinkAboutPermit B96-0069 - LENIHAN DISTRIBUTION RAMP - OVERHEAD DOOR, DOCK LEVELER AND EXTERIOR RAMPCity of Tukwila c
(206) 431-3670
Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188
BUILDING PERMIT
Permit No: B96 -0069
Type: B -BLDG
Category: ACOM
Address: 18200 SEGALE PARK DR B
Location:
Parcel 4: 352304 -9119
Zoning: M -2
Type Const: III -N
Gas /Elec:
Wetlands:
Water: TUKWILA
Contractor License No.: LAPIALP055MZ
Status: ISSUED
Issued: 04/29/1996
Expires: 10/26/1996
Type of Occupancy: WAREHOUSE
Slopes: N
Sewer: TUKWILA
TENANT LENIHAN DISTRIBUTION RAMP
18200 SEGALE PARK DR B, TUKWILA WA 98188
OWNER LA PIANTA LTD PARTNERSHIP Phone: (206) 575 -3200
PO BOX 88050, TUKWILA WA 98138
CONTRACTOR LA PIANTA LIMITED PARTNERSHIP Phone: 206 575 -2000
P.O. BOX 88050, TUKWILA, WA 98138
CONTACT STEVE NELSON. Phone: 206 575 -2000
PO BOX 88050, TUKWILA WA 98138
************************************** k****** * * * * * * *•k * * * * * * * ** * * * * * * * * * ****
Permit Description:
ENLARGE OVERHEAD D00R RELOCATE DOCK LEVELER
AND BUILD EXTERIOR RAMP TO PARKING LOT.
SETBACKS
Units: 00.1 11 Front: .0 Back:. .0
Buildings: 001 Left: .0 Right: .0
Fire Protection: SPRINKLERED
UBC Edition: 1994 Valuation: 6,750.00
Total Permit Fee: 210.34
****** k*****.******************************* * * * ** *** * * * * * * ** * * * * * * * * * * * * * **
4:- 35 __
ij:q (p
Permit Center Authorized Signature Date
I hereby' certify, that I have read and examined this permit and know the
same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate
or cancel the provisions of any other state or local laws regulating
construction or the performance of work. I am authorized to sign for and
obtain this ,rj ding pe •mi
Signature i'
Print Name : C.
Date: 4 Z %•- 2z*
Title:
This permit shall become null and void if the work is not commenced within
180 days from the date of issuance, or if the work is suspended or
abandoned for a period of 180 days from the last inspection.
DE >:
DATE IN .
DATE>
APED •
., ._.-
' ' .REQUIREMENTS / COMMENTS -
,Plan Review
Meeting
3 ry - Rp
� 2 )Jc9 1 '
I n
q V/
NIT. ')DI
BUILDING -
initial review
3 2 yet to
� /_
3 / ..7 /t% R.
(ROUTED)
CONSULTANT: Date Sent - Date Approved -
3RD NOTIFICATION
O FIRE
N A'
A
BY:
(init.)
%-: IREPROTECT ION : Sprinklers Q Detectors OwA
- IRE DEPT. LETTER DATED: INSPECTOR:
.NIT:
O PLANNING
q
4i
ZONING: pAR /LANDUSECONDITIONS? QYes 0 N
IEFERENCEFILENOS.:
INIT:
MINIMUMSETBACKS: N- S- E- W-
WORKS
oo
UTILITYPERMITSREQUIRED? Q Yes pNo
UBLICWORKSLETTERDATED:
INIT:
BUILDING -
final review
24 cl(p 1TYE
OFCONSTRUCTION:
CERT.OF000UPANCY?
QYes , KNo
UBC EDITION (year):
1951'
INIT:
$BUILDING
OFFICIAL
4/04/616
(.))0 lq(,
INIT:
AMOUNT
OWING:
`
CONTACTED
, , t .. • •
�')iz,..►::
\ �
• /
Jot /, 6
DATE NOTIFIED
I
" l r
I n
q V/
BY: / /
(init.) M.
2nd NOTIFICATION
BY:
(init.)
3RD NOTIFICATION
BY:
(init.)
PLAN CHECK
NUMBER
CITY OF TUKWILA
Department of Commv,,,ty Development — Permit Center
6300 Southcenter Boulevard - #100, Tukwila, WA 98188
(206) 431 -3670
Building Permit Application Tracking
PROJECT i h e j31,s - ri bu+i Ofl Pomp
SIT ADDRESS SUITE NO.
CO le , JDr a
INSTRUCTIONS TO STAFF
• Contacts with applicants or requests for information should be summarized in writing by staff so
that the status of the project may be ascertained at any time.
• Plan corrections shall be completed and approved prior to sending to the next department.
• Any conditions or requirements for the permit shall be noted in the Sierra system or summarized
concisely in the form of a formal letter or memo, which will be attached to the permit.
• Please fill out your section of the tracking chart completely. Where information requested is not
applicable, so note by using "N/A ", date and initial.
DEPARTMENTAL REVIEW
"X" in box indicates which departments need to review the project.
REVIEW COMPLETED
02/15/96
SITE ADDRESS SUITE #
j kzoo Segwrc 90,- 'fir%ve "
VALUE OF CONSTRUCTION - $
6, 76 OD
PROJECT NAME/TENANT
2cni 11 cc-. 0 5‘\ -;\-,L-t R►4.v- -r i v
ASSESSOR ACCOUNT #
36'a30q -, 1 /y'
(commercial) L) Demolition (building)
0 Other Q a-vi e
TYPE OF U New Building L] Addition Q Tenant Improvemen
WORK: 0 Rack Storage 0 Reroof 0 Remodel (residential)
DESCRIBE WORK TO BE DONE: ''-v7 /cA.,‘,,.4 0 VEJ. t cl o (T(C 1 Y'e /ve G..4-c at tzek 1e vet c -VL
t---, i I a e X ems-► 6a. v- cam. v-1,0 h Q ig-- -'IL i H g 1 of
BUILDING USE (office, warehouse, etc.)
LU Y4} --el OL.
NATURE OF BUSINESS: Ill) AC E co L.N.;r n —�
WILL THERE BE A CHANGE IN USE? Z No ❑ Yes If Yes, new building requirements may need to be met. Please explain:
SQUARE FOOTAGE - Building: a32 /� /46 Tenant Space: Area of Construction:
WILL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING?
No 0 Yes IF YES, EXPLAIN:
FIRE PROTECTION FEATURES: 3 Sprinklers 0 Automatic Fire Alarm System
PROPERTY OWNER \...c.... PC �� ,;r,•A. ,_c/ 7 4, ..5
PHONE ,t5 ..... ? 5 _ Z000
ADDRESS pv � CDX 88 7�-,lc l4..
ZIP I3g
CONTRACTOR c. / P., I
PHONE
ADDRESS U� a& vSZ0 �t�lac,�.�;, c...,
ZIP qir I3S
WA. ST. CONTRACTOR'S LICENSE # L 4 pa. A 1- P 055 h
EXP. DATE 7-,- 5
ARCHITECT
PHONE
ADDRESS
ZIP
. I HEREBY;CERTIFY. THAT I :HAVE: READ :: AND: EXAMINED THIS; APPLICATION AND THE SAME TO : <;:
;BE TRUE' AND :CORRECT,; AND I. AM: AUTHORIZED TO APPLY;: FOR' THIS PERMIT.
BUILDING OWNER
OR
AUTHORIZED
AGENT
SIGNATURE
_\..e V e
G U
�' •
we \. 0nf
S D s o
DATE
3 -6 - 94
PHONE S75 ZooO
CITY/ZIP_ - FL( l
PHONE
?g i
PRINT NAME
ADDRESS rU
c � ll
CONTACT PERSON
CITY OF TUKWILA
Department of Community Development - Building Division
6300 Southcenter Boulevard, Tukwila WA 98188
(206) 431 -3670
PLAN CHECK
NUMBER
:1:1NI•75:1
APPLICATION MUST BE
FILLED OUT COMPLETELY
BUILDIN PERMIT
APPLICATION
DESCRIPTION
U.
BUILDING PERMIT FEE
PLAN CHECK FEE.
BUILDING SURCHARGE
OTHER: •
TOTAL -
AMOUNT.
RCPT • #
DATE'.
APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the
application completely and follow the plan submittal checklist on the reverse side of this form. Handouts are available at
the Building counter which provide more detailed information on application and plan submittal requirements.
Application and plans must be complete in order to be accepted for plan review.
VALUATION OF CONSTRUCTION Valuation for new construction and additions are calculated by the Department of
Community Development prior to application submittal. Contact the Permit Coordinator at 431 -3670 prior to submitting
application. In all cases, a valuation amount should be entered by the applicant. This figure will be reviewed and is
subject to possible revision by the Building Division to comply with current fee schedules.
BUILDING OWNER / AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or contractor
licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this
permit application and obtain the permit will be required as part of this submittal.
EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall
expire by limitations. The building official may extend the time for action by the applicant for a period not exceeding 180
days upon written request by the applicant as defined in Section 304(d) of the Uniform Building Code (current edition).
No application shall be extended more than once.
If you have any questions about our process or plan submittal requirements, please
contact the Department of CommuHi R Building Division at 431 -3670.
DATE APPLICATION ACCEPT NI D
3
• 'r! Y OF T[
ArE APPLI TION LIIREC
so I 01
ERMIT CENTER
W2193
COMMERCIAL
NEW COMMERCIAL', BUILDINGS /ADDITIONS,
rn Completed building permit application (one for each structure
Assossor Account Number
Two sets (2) of the following;
Specifications •
Structural calculations stamped by a Washington •State licensed
engmeor " <;:
n Soils report stamped by a Washington" State licensed enginee•;
- Topographical 'survey:„:
Energy stamped by a: Washington'Statelicensed :
- engineer or architect
Legal description •
11
Working drawings,: stamped by a Washington State licensed
architect, which include
• Site plan
• Architectural drawings"
• Structural drawings •
• :Mechanical drawings
• Elevations
• Civic drawings
•:Landscape plan
:Completed utility permit application (one for entire project)
Six (6) sets of civil drawings'
NOTE See utility permit application and checklist for specific utility
submittal requirements.
RACK STORAGE
I Completed building permit application
Assessor Account
Two (2) sets of plans, which include :.
Building floor plan showing: •
• Entire space whero
• Exit doors
• Dimensions of all aisles
NOTE: Include dimensions of racks (height, width and length), aisles
and exit ways on plan.
RESIDENTIAL
NEW SINGLE - FAMILY DWELLINGS /ADDITIONS
Completed building permit application (one for each structure)
Legal description
Assessor Account Number
Two sets (2) of working drawings, which include
Tenant space floor plan showing rack storage layout, aisles and
exits.
Structural calculations stamped by a Washington State licensed
engineer (rack storage 8' and over).
• Site plan �. . (On plan, show closest hydrant location.:::
• Foundation plan Include access to building, showing •
• Floor plan :. width and o(access)
• Roof plan
• Building elevations (all views):
•. Building cross - suction
• Structural framing plans
n .Washington State Energy Code data
Completed utility permit application
Six (6) sets of site plans showing utilities
NOTE: Building site plan and utility site plan may be combined. .See
utility permit application and checklist for specific submittal. requirements:
Addtional topographical and soilsanforrnaton may be required if unique,'
site conditions.
SUBMITTAL CHECKLIST
COMMERCIAL';: TENANT IMPROVEMENTS
Completed :building perr n it appl�catlan (one for: each
:;.: tenant)
Assessor: Account Number
Two (2) sots of constructionptans, which include
REROOF
II
11
11
Site plan
• Location Of tenant space
• Existing and proposed parking:
• Landscape plan (11 apphoable, 1 o, change of use
Overall building plan
;Tenant location
• Usa of adjacent (common wall) tenant
• Overall dimensions.ot building or square footage
•Floor plan of proposed tenant space
structure.:
:Tenant space plan with use of each room labelled
• %.'Edoors; egress. patterns
New. walls, existing wall, and walls to be demolished.
Construction details
• . Cross sections showing wall construction and method of
:attachment for floor and ceiling
Structural calculations stamped by a Washington State licensed
engineer may be required if structural work is to be done (2 sets)
NOTE If any utility; work is to be done, submit separate utility permit
application and plans.:::
Completed building permit application (one for each structure)
Assessor Account Number
•
Narrative describing existing roof, material being removed, and
•material being installed. •
NOTE: A certification letter is required prior to final inspection and sign-
off of the. permit.
ANTENNA/SATELLITE :DISHES
- Completed building permit application
Assessor-Account Number
Two sets of plans, which include:
Site Plan (showing building and location of antenna/satellite dish)
Details antenna/satellite dish and method of attachment
Structural calculations stamped by a Washington State licensed •
engineer•may be required
RESIDENTIAL REMODELS
Completed building permit application (one for each structure)
Assessor Account Number
Two (2) sets of working drawings, which include
•.Site plan •
• Foundation plan
• : Floor plan
• Roof plan
Building elevations (all views
• Building :cross- section
•1 Structural framing plans •
NOTE: If any utility work is to be done provide utility permit application
and plans must be submitted
Completed building; permit application (one :for each
•Assessor :Account Number
.Narrative describing existing roof matenal:b eing removed and
material being installed
NOTE A certdication letter Is required prior 10 fina! inspection and sign
off of the permit
GENERA 210.34
TOTAL 210.34
*4k*k •Ak•k *** * *•4k *** *:k his 1 t* *•••1.14 .•l 4c• k•h.K4•A•*k *.: *h*:1t1*hA1 CHECK 210.34 —" TAr10TiI1' CHANGE D.DD
a k*•:1 k:lk .4 4* +.:t 4•k •A ,t:i *:4k *:�• • *•k •1 •k �.:
CITY OF TUKWILA, WA
: tk* k• t, tkskk *k�'c•�•A•k:�:1t.••A:4k*k9e 03/1/96 A , '3 372(iADD0 14.24
TRANSMIT Numk�er : 9 ,�:�( >3E113 Amount: 210.34 03/1.4/ 6 6:3 /•`
Payment Method: CHECK !Notation: SEGALE BUS. PK. Init: UP
Permit No 096.0069 Type: 0-BLDG BUILDING frEI.HIT
Parcel Na: 352304 -9119
Site Address: 18200 SEGALE PARK E)U 13
Total Fees: 210.34
This Payment 210.34 Total ALL Pmts: 210.34
Balance: .00
.4 ** *k *4* * *'*.4 *e4 AA* *A• * *** *:4 *A * *0* * *•k * * A A.* . * * * * :4 *A• *'k ** * *a:4* * * * *^4 *t4*
Account Code
000 /322.100
000/345.830•
000/386.904
Description
BUILDING - NONRES
PLAN CHECK NON12E$
STATE BUILDING SURCHARGE
Amount
124.75
81.09
4.50
Project:
%
Type of inspection: i . fri f )
Address:
L D 0,66
< � ` Date
Date called:
O I O j J 9 (40
Special instructions:
1
wanted:
g m. 1
t p .r�f
c,
Requester:
Phone No.: .
6 2 _ 9 q tp
INSPECTION RECORD
1 Retain a copy with permit (p v
INSPECTION NO. n PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION Mlb
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) 431 -3670
Ig per applicable codes.
COMMEDJTTS:
Inspector:
Date:
9 hco
Corrections required prior to approval.
$42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must
be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
5
G
Project: /
,--k) 441
Type of inspection:
Address:
Date called: 4' /3^44
Special Ins ructions: :
/$j �
��
Date wanted: / 47
(� �' ` ��
a .
p.m.
Requester:
Phone No.:
INSPECTION NO.
p
INSPECTION RECORD
Retain a copy with permit
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
PERMIT NO.
(206) 431 -3670
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
cct
Inspector:
a A At,-
:r274111-,
Date:
I $42.00 REINSPECTION 'EE REQUIRED. Prior to inspection, fee must
be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
surera ra b :uw:;c .srdrt."4t irrl.,;.x_- &::.:he C._ r.:}t I SA” ..,:..7:1111e,_^9,111Mi..4..
1
COMMENTS:
Type of i s L
�i
be dress
Date called
xZ. A p P (vA
g_,_E - r
y o u ( P LA ►J cm-AA g Eiv-- 3p # FaT
4
0G
s Liss 606E. a_ ) s oLg1to ►J •
Phone N o
t
..--.
taciti4A1,1 b i 1 m� rl t C�/J�
Type of i s L
�i
be dress
Date called
Special instructions:
LATE Pi PLeAs
a e w n;
Requeste Y_ ` e
Phone N o
t
INSPECTIO
NO.
_ .SL.. _�.._. .re.k__:..
Approved per applicable codes.
INSPECTION RECORD
Retain a copy with permit
CITY OF TUKWILA BUILDING DIVISION •
6300 Southcenter Blvd., #100, Tukwila, WA 98188
1
PERMIT NO.
Corrections required prior to approval.
Inspector:
Date: r 1 f 9 to
$42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must
be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
(206) 431 -3670
t'
Project: 1....,
k- a.)......'.d
Type of in Ion: t i■ 6 �
�
Address) y26U
Date calla 1:
Special instruction
t' 1'
11
�
�U
•
Date wanted: �✓/ZZ1
-1 �
a.m.
,�
Requester: of> ips,........,
.w
Phone No.: S-7 S
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
I I
Approved per applicable codes.
PERMIT NO.
(206) 431 -3670
COMMENTS:
Inspector:
\, C (ss...) _.--
Date: G/
Corrections required prior to approval.
$42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must
be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
Project, 01/4._
Ar, ' ` FOAAA
W
Type of inspect •
IGx
� 7 rr
V ,�f ,
�``
Address: v z
Date called:
Special instructions:
k . ‘r .
1 2(.6D
Date wanted:
S a.m.
C �� fr
Requester:
p
>
Phone No.:
5 .7 C
CITY OF TUKWILA BUILDING DIVISION
Approved per applicable codes.
I Receipt No.:
. w_
INSPECTION RECORD
Retain a copy with permit
I
PERMIT NO.
6300 Southcenter Blvd., #100, Tukwila, WA 98188 " ,(20fj) 431 -370
CO c
t 2s / f
� �1
T
Corrections required prior to approval.
$42.00 REINSPEC FEE REDUI • ED. Prior to inspection, fee must
be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Date:
Projecti _
Type of inspection:„,...
Address: 1
g2_6t1,_ / A 6
Date called:
Special instructions:
W /4/15
g4 -
Date wanted: 96/ c a.m.
Requester:
.41-e--
Phone No.:
INSPE ION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
J Approved per applicable codes.
COMMENTS:
Inspector:
I 1
INSPECTION RECORD
Retain a copy with permit
S ceo
(206) 431-3670
Corrections required prior to approval.
1111■
•••••••
R vh-e-7 4- colid‘., 7
Date:
5"--/
$42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must
be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
Address: 18200 EGALE PARK DP 13
Suite:
ienant: LEN1NAN DISTRIBUlION RAMP
'Type: B-BLDG
Parcel #: 352304-9119 •
44.4-44.A*44*****'4 *****A444**4**4 .44A-44Ar'4 ***-44'4 444444**44444**4'44 4***4 44 4 4
Permit Conditions:
1. No changes will be made to the plans unless approved by the
Architect or Engineer andt.he.-Tulr.wilaBuilding Division,
2. All permits, inspectioniiseoordand.Oppa.v,ed Plans shall be
available at the Jok to the- any con-
struction. TheseA6ouments:r
ae td -,be maine an
alned.d avail-
able until finajl is 4ranted.
Notify the City or,. 'FuIw1a Buildin§ Divi'sjOn
Placin9 . .Y - itoncr;ete'.-:, This procedr
u'e is in additiOnto any
,,..
requirements for 4
4. All conyupt,ion.-tb ti,e'donela .conformancewith,sapproi:e
plan sisind reqUiremerit's of ti:le Building Code, Al9F4-
Edityp40 as amended, Uni Mechanical Code (1994:
..,, „
and*a:Shii
tnton Statey;peegY: (1994 Edition)
---.
Valfdity of Permit jhe isSuance of a permit or
plan, 6.6c.ifiCations and Cps4 shall not beycon.L. H2..
, - - - , - .
stilded to be a permit - for -or ln lobroval of. any viotation--
, , . ,. ..
_ .
offily of the, provisions at the building cod or of -
ot4er ordinance-of,t4eidrisdictiOn: :No presuMin9-to
glve amthorityyto_OOlateor cancel the provisioris O
code shall 1:)-, valid,
•
CITY OF 1UK4 1LA
Permit No: 896-006Q
Status: ISSUED
Applied: 03/14/1996
Issued: 04/29/1996
April 17, 1996
Mr. Steve Nelson
Segale Business Park
P.O. Box 88050
Tukwila, WA 98138
Dear Mr. Nelson:
KAH:maf
Re: Construction of Ramp over Watermain
We have reviewed your plan to construct a new ramp for the warehouse located at the
southeast corner of Segale Park Drive "D" and Segale Park Drive "B ". The ramp will be
constructed over a 10" diameter C.I. watermain. This main is a portion of your private fire
system and is not controlled by the District.
We do not object to the construction of the ramp.
Please call me if you have any questions.
Sincerely,
L/P1 64A-41;
Keith A. Harris
Manager, Planning /Construction
Serving the Southwest Metropolitan Area since 1946
RECEIVED
CITY OF TUKWILA
APR 2 4 1996
PERMIT CENTER
23828 - 30th Ave. S. • P.O. Box 3867 • Kent, WA 98032.824 -0375 / FAX: 824 -0806
O01
°Do
A nders , --n - Peyton
Structural Engineering Consultants
A Division ojACP Consultants, Inc
31620 23rd Ave. South, Suite 321 F ederal Way, WA 98003
Phone:(206)941 -9929 Fu: (206)941.9939
MemoPad 2
from
Brian A. Dickson
E TeLog
❑ Confr.
❑ Info:
Page t of_y_
Distribution
Date:
1/26/96
Time:
8:00 a.m.
Steve Nelson
Project:
Segale Building 763
Project No.
96025
Dean Peyton
Person:
Steve Nelson
Phone No.
575 -2000
Company:
Segale Business Parks
Fax No.
Subject:
Structural Inspection
Sent Via
Fax ❑ Mail ❑
Billing File ❑
Steve -
Per our previous discussion, inspections for the subject project shall conform to the requirements of the 1994 U.B.C. in lieu
of the plan requirements for inspections to conform to the 1991 U.B.C.
If we may be of any further assistance or if you have any questions, please feel free to contact us.
Sincerely,
Anderson Peyton
Structural Engineering Consultants
O
Brian A.
Design Engineer
Enclosure: (None)
C:\8 W ORK\CRSPNDNC\MEM09S.00C
RECEIVED
CITY OF TUKWILA
MAR 1 4 199
PERMIT CENTER
01/26/96 8:29 AM
‘--.. ; . 7 REGISTRATION' NUMBER
EXPIRATIONDATE •
T ;r,
_
: OSSM
. Ft=ECTTVE 11ATE
.07/43.9..476
47%09
LA PIANTA':.1•IML1ED• PARTNNERSHL
PO' BOX . '88010 • •
TUKWILA . WA - .98138
DEPARTMENT OF LABOR AND INDUSTRIES
THIS CERTIFIES THAT THE PERSON NAMED HEREON IS REGISTERED AS PROVIDED BY LAW AS A
STATE OF WASHINGTON
RECEIVED
CITY OF TUKWILA
MAR 1 1996
PERMIT CENTER
•
F825-05240013.921
WATER ' VALVE g
wATER METER
FIRE 024 IrPr.
- •
; .
/592.136 \
10.77
\ \
N 07°46'24' E '14
2400\ \
\\\
•5132°1336E
20.00
. . SEGALE PARK DRIVE--"B sAN.sEw. mw
A =13'06'17. N 07° 41' 08" E -?- - 7-- ----
206.95 ---=_•...--._
R #1164.55
L 4 266.36 f • - -----
GAS VALVE WATER VALVE
VOTER METER WOTOS METER SPRINKLER VALVES
MN.
MIXE1154458wEstim mmawm i imag a gewasurmirmw
RE h8 .T AbRoune-ger
.\•\<
t WATER LINE ESAIT ' s °_,„/
FAVOR OF KING CO W.D. 5 ' N
co..n ;-/
/
a
isimignap WATERP
4
46N 07 24' E
xsx \\\\\\ a \
#%•(
\ \\\\ \\*\
NORTHATSTERLy-. BLDG. LINE
• . .
11CA
•
• , • 1
+o docst '
SOUTHEASTERLY BLDG. LINE
\ s \
.• 550. n4
ze# ESMT. IN FAVOR or 051000o WAUKEET _
A ° 40 'i 00
Sr. AWL AND PACIFIC RR, UNION PACIFIC R.R.,
AND OREGON AND WASHINGTON 5.5. 0240 NAVIGATION CO. 6.477.47
ADD. FILE NO. 7707050078 1 • 9 7.2 2
CONCRETE OFFICE
END WATER ESMT.
FIRE 105 N VALVE
N 07'4624 ' E 0105
\
N 82 .
SURVEYORS CERTIFICATE
I hereby certify that this map correctly
represents a survey mode by me or
under my direction this -2DL day OF
Registered Land Surveyor I-.1.r No.
*.4
•-•• - _„ • . ,
INVER VALVE
[77/ATER LINE ESmT. iN
favoW'or 141.6
• 77°41'04"
R • 40.0
.L • 54.23
Am FAT ANL
:•,, 6 . J70'22k R.R. SPUR TRACK
P
' 47 7 47 \ . \ \s s'
L . 08.33 .` \\ q
•
• LEGAL DE0CRIPT1053
i
••
• , •
. . . • , , . . '
. .
. • • •
PARCEL NO 1. • ' i I
••••• ,
That portion. Of the Southweet. Quarter of the Northeast Quarter and Government
. .
11 Lot 5 ALL in Section 05, Township 23 North Range 4 East, N.M.', in King County,
Washington, described as. follows: • .
. . '
. , .
• . BEGINNING at a monument at the Northeast c rner of the said Southwest'Quarter
of the Northeast Quarter; thence South 07 West, 500.14 feet; thence
• North. 87°50'09" West, 212.77 feet to the TRUE POINT OF BEGINNING; thence along
a 14° curve to the left whose center•bears South 48°22'43" East, having a radius
of 409.256 feet, through•a central angle. of 22°12'21 an arc distance(of 158.61
feet; thence South 19 West, 101.32 feet to the Northwest corner of Parcel
731, as recorded under. King County Auditor's File No. 7512040188; thence con-
tinuing South 19°24'56" West, 59.97 feet to a point of curve; thence along a
12° curve to the•left having a radius of 477.47 feet through a central angle of
11°40'00 an arc distance of 97.22 feet; thence South 07 West, 213.72
feet to the Southwest corner of said Parcel 731; thence continuing South 07°44'56"
West, 48.23 to a point of curve; thence along a 12° curve to theiright '
. having a radius' of 477.47 feet through a central angle of 13°00.00. an arc dis-.
tante of 108.33 feet; thence South 20°44'56" West, 399.00 feet to theNouthwest
• corner of Parcel as recorded 004SF King County Auditor's File No. 17507030075;
thence contihuing South. 20 West, 511.97 feet to the Southwest corner of
• .. Parcel 752 as'recorded under Ring County Auditor's rile No. 7608160055; thence
North•66°31 West, 270.97 feet to a point of curve; thence along a.curve to
the right having a radius of 50.00 feet through a central angle of 87 an
arc distance of 76.20,feet; thenCe North 20°47'25" East, 791.84 feet to a point
of curve; thence along a curve 'to the left having a radius of 1,164.55 feet
through a central angle of 13 an are distance of 266.36 feet; thence
North 07°41'08" East, 206.95 feet to a point of curve; thence along a curve, to
the right having a radius of,1,099.89 feet through a central angle of 06°47'39"
an.arc distance of 130;43 feet;. thence North. 14°28'47 East, 82.13 feet to a '
point' of curve; thenceNlong, a.curve to the right having a radius of 40,00 feet
thrOugh.aticentralangle.,af. 77°41'04° an.aro distance of 54.23' feet; thence
South. 87°50'09 feet ta TEEN POINT OF BEGINNING. •
• Doe
RESERVING an easement for side walk and utility purposes over the Northerly
15.00 feet, over the Westerly 15.00 feet and over the Southwe terly 15,00
feet thereof.
RESERVING the right of ingress and egress to maintain, instal , improve and
extend utilities.
RESERVING an easement for railroad purposes, including, but not limited to
maintrack, lead track and spur tracks, as well as for access and storage, over
that portion thereof lying' Southeasterly of. the Southeasterly building line
produced.
RESERVING an easement for water line purposes 15 feet wide, having 7.5 feet
described inn t l' •
• •
BEGINNING at a monument at the Northeast 'corner of the Southwest 'Quarter of
the Northeast Quarter. of, the said Section, 35; thence South 07°44'56" West,
--500,14. feet; thence North 87°50'09" West, 329.73 feet; thence South 07°13'41"
West, 15.06 feet to the TRUE POINT OF BEGINNING; thence continuing South
07°1341 West, 246.77 feet to the terminus.
RESERVING an easement, for common access purposes, including ingress and
egress over' the following described portion thereof:
BEGINNING at a.monument at the Northeaat corner of the Southwest Quarter
of the Northeast Quarter of the. said Section 35; thence South 07°44'56
West, 500.14 feet; thence North 87°50'09" West, 212.77 feet to the TRUE POINT
OF BEGINNING; thence along a 14° curve to the left whose center bears South
48°22'43" East, having a radius of 409.256 feet, through a central angle of
19 an arc distance of 142.22 feet; thence North 82°30'02 West, 66.82
feet;, thence North 07 Soot; 117.51 feet; thence South 87°50'09 East, .
I SITE ADDRESS:
124 74 f N to Nh TREE POINT OF OEGINNENG
TOGETHER WITH AND SUBJECT TO an easement for building setback purposes over a
60 feet wide strip of land surrounding and adjacent to the main building line, ,
which is described as follows:
BEGINNING at a monument at the Northeast corner of the Southwest Quarter of
the Northeast Quarter Of the said Section 35; thence South 07 West,
500.14 feet; thence North 87°50'09" West, 337.51 feet; thence South 07°46'15"
West, 117.51 feet to the TRUE POINT. OF BEGINNING; thence continuing South :1
07°46'15 West 537.39 feet. thence South 20°45'48" West, 949.89 feet; thence ' I
North 69 West, 209.96 feet; thence North 20°46'05 East, 116.00 feet;
thence South 69 East, 20.00 feet; thence North 20°46'05" East, 637.87
feet; thence North 69°13'55 West,'20.00 feet: thence North 20°46'05" East,
123.69 feet; thence South 82°13'36 East,' 10.77 feet; thence North 7°46'24
East 24.00 feet- thence South 82 East, 20.00 feet; thence North 07
East, feet;' theses North 82 West, 20.00 feet; thence North !,
07 East, 101.05 feet; thence South 82 East, 210.01 feet to the
TRUE POINT OF BEGINNING.
(See sheet 2 for continuation)
WNW m■A C
c , \ : 0 4;
R.LEAD TRACKS AR cx
ATTACHMENT #1
SBP/MAS BUILDING 763
6,.22
R. 409.26
L.158.61
PARK/NG-
suz.syco.S4
3.:„Enearvexps
LEGEND
CB . CATCH BASIN.'
DS :DOWN. SPOUT t
•
, STORM SEWifi';,
NATURAL
WATER •
A FIRE HYDRANT
SANITARY SEWER
-E • ELECTRICAL
OUTSIDE LIGHTING
I PROPERTY CORNER
\ CASED. MONUMENT..
- ' FiLe COPY
rAd,ornOsIoni
.1 1.00 net autheilite ths vIOIMIonItf .E.v
i:d•W 604 ee e5 liol56 1111619tiifeicisn*tpi'S
ci .
\
i zee... 1' to 0 0 (09
t m
• - REVISIONS
r Cle CHANGES SHALL BE MADE TO
I H SCOPE OP WORK WITHOUT PRIOR
IA ROVAL OF. TUKWILA BUILDING DIVISION
o 4EE PENISIONS WILL REOU REV NEW PLAN DAN - 7
•
• , CITY OF TUKWILA.
APPRO '; , •
• • , • • •• •
APR 2 ':.1596
AU tL0ILJ,JL#
131/11.01/40„, IIVI5II4 '
oNVO
PERMIT CENTER
waive •
- •
Poe NE CORNER, SW 1/4.
RAMC
vrtn. TUN CY
NE 1/4, SECTION 35'
T23N, R 4 E,W.M..
SAID MONUMENT IS AT '
• THE CENTERLINE OF
S. 180TH ST-, A PUBLIC
66'W ..
CITY Ln-
PLANNING DEN
ANDOVER PARK WEST
• SEGALE • BUSINESS. PARK, '
, • AT.A..SURVEY-BOILDING
I, ; a 5e4 F1;:= 3 5 3°" .
- ,7*4a101: A011YeAliWGI
:,26(6Wf;;
me KA
OAS VALVE
e
-WATER PIPE
N 20 \ 46 05 E
116
N 20.6 E
116.00
PROPANE TANK
SAN. WW. MA.
I
.6° 9 - ` R ESMT. Water ea s'elnent n favor of King Cou y
as recorded under Auditor's File No.' 780302
CS
P.S.P.
see LYE HY 5. 1� L — - F=+-:: - \ _
t lets' t " / \ , W ATERS
1
--- =
_`�. --- /c9 �"'L ASPHALT �; • \' Ib2 "sTe .
IEEL
NORTHWESTERLY: - BLDG. LINE
868.17
CONCRETE OFFICE- WAREHOUSE
R SPUR TRAC
. _ M
7 c8
AND R.R: LEAD TRACK EASEMENT'
PO WER .'9 .-" ^• , �yy�el rh` y4LP� f �y}1�.+\ y � `A
=.:"" ii4._T�'£i'R,. ,�j' aY' i�S•` h!- ">( ♦� -
OS ataniummiwit■Immisomommiqgmti Ng
$Pfll `R R �- L R hETER � - CO RLM. LVE
SOUTHEASTERLY B4DG. LINE
ATER
IINDERGIVAID ER
SUEWAL
CITY OF TUKWILA
APPR0000
1 APR 2 4 1996
1 05 N0110
\ \\\7 . BUILDING OIV10" I -- '
'h IRON OlIt
M
2 :
b
08
WATER VALVES
0 PAVEMENT
R. R. SPUR TRACK
\ \ \ \\ \\ \\\` \\\\\\� \\ %\\\ \\1\\‘\\% %\\‘%%‘% \\\\\\\ \\\�
EXISTItJG WAREHOUSE
.' (LEGAL DESCRIPTION CONTINUED) BLDG. NO. 752
,TOGETHER WITH a. non exclusive easement for ingress, egress, and utilities
purposes, 60 feet'in width, having ,30 feet on each side of the following
described centerline:.
BEGINNING at a monument at the Ntheast corner of. the Southwest•Quarter of
the Northeast Quarter of Section 5, Township 23 North,. Rang 4 0050,. 00.9 . ,
in King County,. Washington; then South 07'44'06 "' West, 470.00 feet; thence
;North 87°50'09 " -West, 628:86 feeti'thence. South 14 West, 138.49 feet
.to a point of curve; thence along a curve to the left having a adiusof •
1,129.89 feet, through -a centre angle o£ 6 ", an arc distance -of 133.98
feet; thence South 07 " - We t0 feet to a point of curve; thence
along a curve to the right haviO a radius of 1,134.55 feet through a central
angle of 13 arc distance of 259.50 feet; thence South 20
,West, 868.17 feet, th ce Sout66'31'27" East, 347.30 feet t - the terminus
of this easement centerline. CEPT'.that portion thereof lying within South
180th Street. ' - .. - •
•
SUBJECT, HOWEVER, to the righ¢ of Owner and Owner's successors in title, to
relocate said easement within Segale.BUSiness Park on the following terms
and conditions:
(1) Any such relocation shat perpetuate similar rights of ingress, egress
and utilities. to'a public reed;
I(21 The `s width of d relocat d easement and the phy ical surfacing thereof
ha11be similar to that of.. th initial easement;
(3) The route of said relocated easement shall reasonably direct
access to a, public road;'
(4)., The legal rights. of Mortgagee and Mortgagee's .successors ' in
and to route of said relocated easement shall be substantially the same as
with respect to.the route.of the nitial easement;
(5) Said relocated .easement sh ll.be appropriately documented by a supple-
ens to this Assignment containing a revised legal description. and shall
be insured at the expense of Owner by a .title. insurance' company on the same'-.
basis as the original relocatable easement..
(6) : The expenses of such relocation, including the construction And sur-
.facing thereof, shall be the sole responsibility of Owner or Owner's
'successors . in title;
.'.PROVIDED, HOWEVER, that no such relocation shall be permitted f;.in the
opinion of independent real estate appraiser (M.A.x ) as selected' by the:
Mortgagee, the : fair market value of the secured property as of the date...
of relocation of•said - - easement would be -reduced by r on of 5050 reloca-
tion' below the fair market value of the secured property as- of the date of I
execution of this Assignment, as by Mortgagee prior to the
execution date - hereof. The expenses' of such appraiser shall be paid by the
!000, 0 or OWner.'s:,aucceseor i'n . title,;:._ -
c
20'ES EWE IN FAVOR OF CHICAGO MILWAUKEE ST TAUL AN p PAH R.R • ��. —t
LEGEND • BLDG. NO: :733
CB - CATCH BASIN
DS. DOWNSPOUT"
STORM. SEWER
—9--- NATURAL GAS!
- -- WATER
A . FIRE HYDRANT' •
- -- SANITARY SEWER,
— E — .ELECTRICAL'
OUTSIDE LIGHTING
CASED MONUMENT.
O PROPERTY CORNER
;q .RAMSETNAIL' BITE. ADDRESS:
LE O. 77070900.70
A r FIRE HYDRANT AND 'VALVE '
Q PARKING
/C/ ' COMPACT
Revision'(A6 /e, Linz kaccv'ding it e.) 320 -77
Aev)sron — AL Rin1ry- . 0-83
E VE0
PERMIT CENTER.
SURVEYORS CERTIFICATE
I hereby certify 81106 this map correctly
represents. a survey made by me or
under my Eireu)on - .thta 2)st day. of....
/0396
. Registered Land Surveyor L.S. No.
18200 - 18340 SEGALE PARK DRIVE 8
=SEGALE: BUSINESS PARK
A:r.A : SURVEY - BUILDING NO 763'_:
TIil)WILA NASNPJGTON
8w w.li.w IlwoO . ANSO.IEF wn ti t 704x v
''2690 9-23-77 Iwo "A71'
i
TYPICAL
ACI MIN. CLEAR + 1/2" MAX
REINFORCEMENT PLACING
NOTESI
1 VERTICAL REINF. SHOWN IS ADDED IF NORMAL
WALL REINF. IS NOT IN PROPER LOCATIONS
2. CORNER BARS ARE SAME SIZE AND SPACING
AS HORIZ. REINF.
3. 90' HOOKS MAY BE SUBSTITUTED FOR
CORNER BARS (SEE NOTE 5).
4. REINF. AT ALL WALL CORNERS, ENDS AND
INTERSECTIONS SHALL BE FABRICATED AND
PLACED IN ACCORDANCE WITH APPROPRIATE
DETAIL SHOWN.
5. USE ACI MIN. 90' HOOK FOR EMBEDMENT
LESS THAN 24 DIAMETERS PAST FACE OF
WALL.
6. CONCRETE WALLS SHOWN; MASONRY WALLS
SIMILAR.
7. WALL DETAILS SHOWN, FIG. DETAILS SIMILAR.
8. VARIOUS WALL SECTIONS AND INTERSECTIONS
SHOWN; USE APPROPRIATE DETAILS.
DIAGRAM
OPTION /1 CONDUIT PASSES BELOW FIG
TOP OF FOG.
(
7 EXISTING TRENCH
NOTE: IF CONDUIT 0 SAME S • FOR CONDUIT
ELEV. AS WALL FTC., STEP x S 1`
D
•
OWN TO ALLOW CONDUIT 5111111
TO PASS THRU WALL PER
THE TYPICAL STEPPED FTC.
DETAIL
OPTION /2 CONDUIT PASSES RU WALL
CONC. WALL 4
4' -0" MAX
WALL FAG. WILL
ADEOUETLY
SPAN 4' -0"
#4 TRIM BARS
AROUND OPENING
(EA. SIDE & S 45')
24 "x24" MAX.
OPENING
TOP OF FIG.
) TYP. CONDUIT INTERSECTION
AT OWNERS OPTION
PROVIDE #4 NOSE
BARS FOR CRACK
CONTROL
#4 REINF. TO STOP SLAB ON GRADE PER
0 CONTROL JOINT DET. 1/51 (SLOPE PER
PLAN)
CONTROL JOINT @ SLAB ON GRADE
CONTROL JOINT 0
20' -0" O.C. MAX.
(LOCATE PER OWNER)
STOP REINF
0 JOINT
WIDTH OF WALL
CONTROL JOINT @ WALL
CONTROL JOINTS
- AT OWNER OPTION
PROVIDE D
SMOOTH SURFACE FOR
RAMP SLOPE TRANSITION
1/2" DEEP CHAMFER
MIN. DIM. TO BE
SAME AS FTC.
THICKNESS
_J TYPICAL STEPPED FOOTING
REINF. TO BE SAME AS
LONGITUDINAL BARS. _
PROVIDE MIN. 24" LAP
W/ LONGITUDINAL REINF.
FIG
THICKNESS
CNC 104
EXIST, TILT UP WALL �\ I
PANEL BEYOND \ I
(2)- LAYERS OF 30#
FELT FOR SLAB ISOL.
& PROTECTION OF
EXIST. STRUCTURE
EXIST. CONC WALL
FELT PROTECTION
BOARD PER OWNER
AGAINST EXIST. CONC.
STRUCTURE
�V 1
MC10x8.4 W / #4 WELTMENTS
x 24" MIN. 0 14" O.C.
NEW PORTION OF 6"
SLAB ON GRADE 0
INT. W /#4 0 14" O.C.
EA. WAY 0 fL DOWEL
INTO EXIST SLAB
DOCK LEVELER TO BE
REMOVED
_J NEW SLAB TO EXISTING SLAB
1/2" REVEAL
PER OWNER
PROVIDE VERTICAL
WALL CONTROL
JOINTS PER DET.
4 /St
H PLACE REINF. PER
I. DET. 6 /51
STEP FIG'S AS LEO.
PER DET 3/01
RECOMPACTES
GRADE / NEW
ASPHALT IN
FRONT OF WALL
ADD'L #4 FOR
STEM REINF.
PLACING
PROVIDE #4 x 24" CORNER REINF.
0 FTC. & WALL
CORNERS
1" CHAMFER PER OWNER
30# FELT FOR SLAB ISOLATION
6" SLAB ON GRADE W/ #4 0
14" O.C. EA. WAY 0
4" TO 6" OF COMPACTED
GRAVEL BASE 1-"
2 6
(12" WHERE SLAB HEIGHT
IS LESS THAN 24" ABOVE
FINISHED GRADE IN FRONT
OFF WALL)
TYPICAL @ RAMP WALLS
WELL COMPACTED SUB -BASE
#4 x I= 0 10" O.C. (16" O.C.
WHERE SLAB HT. IS
LESS THAN 24" ABOVE
12' FINISHED GRADE)
#4 0 16" O.C. CONT. HORIZ.
4 "0 PERT PVC DRAIN TO
yr DAYLIGHT (OR 2 "0 WEEP HOLES
THOU WALL 0 48" 0.C.) PROVIDE
12" STRIP FREE DRAINING MAT'L
0 BACK FACE OF WALL (NOT
SHOWN)
#4 0 10" O.C. HEEL REINF.
- 2" CLR.
#4012" O.0
CON T.
STRUCTURAL NOTES
1.0 GENERAL
1.1 CODES
THESE STRUCTURAL NOTES SUPPLEMENT THE SPECIFICATIONS, ANY
DISCREPANCY FOUND AMONG THE DRAWINGS, SPECIFICATIONS,
THESE NOTES, AND THE SITE CONDITIONS SHALL BE REPORTED TO
THE ARCHITECT, WHO SHALL CORRECT SUCH DISCREPANCY IN
WRITING. ANY WORK DONE BY THE CONTRACTOR AFTER DISCOVERY
OF SUCH DISCREPANCY SHALL BE DONE AT THE CONTRACTOR'S RISK.
THE CONTRACTOR SHALL VERIFY AND COORDINATE WI THE DIMENSIONS
AMONG ALL ONC ALL DRAWINGS PRIOR TO PROCEEEDING ING WITH ANY WORK OR
ANDRICATION, THE CONTRACTOR IS IS RESPONSIBLE -FOR ALL BRACING
AND SHORING DURING CONSTRUCTION,
ALL METHODS, MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE
REQUIREMENTS OF THE CITY OF TUKWILA AND: THE 1994 UNIFORM
BUILDING CODE (UBC), AS AMENDED AND ADOPTED BY THE CITY OF
TUKWLA AND THE STATE OF WASHINGTON: A.C.I. 318 -89 (REVISED
1992): A.I.S.C. 9TH EDITION. A.I.T.C. 2ND EDITION; AND
A. I.S.I 1986 EDITION AND 1989 ADDENDUM.
1.2 DESIGN CRITERIA
A. VERTICAL LOADS
1. LIVE LOADS
LIGHT COMMERCIAL VEHICLE TRAFFIC 200 PSF
1.3 SOIL DATA
VALUES ARE ASSUMED AND ARE TO BE FIELD VERIFIED, SOIL
BEARING 0 CONT. SPREAD FOOTINGS = 2000 PSF. EQUIVALENT
FLUID ACTIVE PRESSURE AND PASSIVE PRESSURE ARE ASSUMED TO BE
35 PSF AND 350 PSE. RESPECTIVELY. SOIL UNIT WEIGHT IS
ASSUMED TO BE 120 PCF AND THE SLIDING COEFFICIENT IS ASSUMED
TO BE 0.50.
2.0 STE NO I(
2.1 EXCAVATION
EXCAVATE FOR FOOTINGS DOWN TO DEPTH SHOWN ON DRAWINGS OR TO
FIRM UNDISTURBED MATERIAL. AREAS OVER- EXCAVATED SHALL BE
BACKFILLED WITH LEAN CONCRETE (Yc = 2000 PSI), OR BE
STRUCTURALLY FILLED PER SECTION 2.2 AND SHALL BE AT THE
CONTRACTOR'S EXPENSE
2.2 BACNFlLL MID COMPACTION
BACKFILL SHALL NOT BE PLACED UNTIL AFTER THE REMOVAL OF ALL
FORMS. SCREEDS, OTHER WOOD DEBRIS AND MATERIAL SUBJECT TO
ROT OR CORROSION. USE ONLY MATERIALS APPROVED FOR BACKFILL.
IN AREAS UNDER SLABS OR FOOTINGS, MATERIAL SHOULD BE
GRANULAR IN NATURE. PLACED IN 6 -INCH LIFTS AND COMPACTED TO
AT LEAST 95% OF MAXIMUM DRY DENSITY AS DETERMINED BY AASHTO
COMPACTOR TEST. PROCEDURE T -180. THE FILL SHOULD BE
LIMITED TO CLEAN. GRANULAR MATERIAL.
3.0 CONCRETE
3.1 GENERAL
NORMAL WEIGHT CONCRETE MEETING THE REQUIREMENTS OF ACI 301-
89 ESTABUSH PROPORTIONS OF CEMENT, COURSE AND FINE
AGGREGATES, WATER. AND ADMIXTURES TO PRODUCE THE PROPERTIES
SPECIFIED FOR EACH CONCRETE MIX TYPE PER ACI -301 ON THE
BASIS OF PREVIOUS VIOUS FIELD EXPERIENCE OR. TRAIL BATCHES. A
E
WATER PR ADMIXTURE RE 500 IN ALL CONCRETE SIXES
FOR THIS IS PROJECT. CONCRETE N ALL ANDTE TB 50 PSI AND OVER SHALL
INCLUDE A SUPERPLASTICIZER ER AND BE FLOWABLE N TO INCH
SLUMP). USE ADMIXTURES CCORDAANCE E WIT- H THE
MANUFACTURER'S DIRECTIONS. CI RECTO PE. . USE AMOUNTS OF WATER- REDUCING
ADMIXTURE THAT WILL PERMIT PLACING T WITHOUT FON,
HONEYCOMBING R ROCK POCKETS. THE ITE SL OFUMP SPECIFIED SPECIFIED LED ARE THE
SLUMPS REQUIRED IEED RT THE POINT T
OF PLACEMENT INTO THE
STRUCTURE. U U N INTERIOR MECHANICAL COS WITH RPM
MINIMUM FRR USE DO NOT OVER-VIBRATE. SHALL CONCRETE SH C BE
PINOUS MONCTTA FRE BETWEEN CONSTRUCTION OR CONTROL
JOINTS. PROTECT ALL LL AL FRESHLY PLACED CONCRETE FROM PREMATURE
AF AND EXCESSIVE HOT COLD TEMPERATURES FOR SUN DAYS
AFTER TER POURINING. . PROVIDE ENGINEER FERR WITH PROPOSED CONSTRUCTION
OR CONTROL JOINT LOCATORS FOR HIS APPROVAL, L, OR SHALL JOINTS
AS SHOWS WN TH
ON THE DRAWIRAWINGS. GS. RS ALL RS AND ANCHORS CUT
OFF FLUSH WITH THE FROM SURFACES WHERE ARACES WCONE EXPOSED S ESLL
EE DMEDTH AND FREE IR E SLAM IOREERLTRITIES. SONDUIRS & S & PIPES
WITHIN THIN THE SLAB (OTHER THAN THOSE MERELY PASSING
THROUGH) SHALL SATISFY THE FOLLOWING:
12 STRENGTH
1. THEY SHALL BE NOT LARGER THAN ONE THIRD THE
OVERALL THICKNESS OF THE SLAB IN WHICH THEY ARE
EMBEDDED.
2. THEY SHALL BE SPACED NOT CLOSER THAN THREE
DIAMETERS OR WIDTHS ON CENTER. AT ELECTRICAL
ROOMS OR CONGESTED AREAS WHERE MINIMUM SPACING
CANNOT BE ACHIEVED. USE #6 AT 12" O.C. EACH WAY
EXTENDING A MINIMUM OF TWO FEET BEYOND CONGESTION.
MORE THAN ONE LAYER OF CONDUIT IS NOT PERMITTED
UNLESS APPROVED BY THE ENGINEER.
3. THEY SHALL NOT IMPAIR SIGNIFICANTLY THE STRENGTH
OF CONSTRUCTION.
4. THEY ARE NOT EXPOSED TO RUSTING OR OTHER
DETERIORATION.
5. THEY ARE OF UNCOATED OR GALVANIZED IRON OR STEEL
NOT THINNER THAN STANDARD SCHEDULE 40 STEEL PIPE.
DESIGN MIXES TO PROVIDE NORMAL WEIGHT CONCRETE WITH THE
FOLLOWING PROPERTIES:
APPLICATION STRENGTH MAXIMUM MAXIMUM
F'c WATER /CEMENT SLUMP
(PSI) RATIO (INCHES)
ALL CONCRETE 2500 0.46 4
SUBNOTES:
ANY OF THE ABOVE MIXES CAN BE USED FLOWABLE (8" TO
11" SLUMP) IF THE PROPER ADDITION OF ADMIXTURES IS
INCLUDED AND THE W/C RATIO IS NOT INCREASED.
2. NON- STRUCTURAL CONCRETE SUCH AS SLABS ON GRADE MAY
OR MAY NOT CONTAIN WELDED -WIRE FABRIC PER SECTION
3.55 OR FIBER -MESH. HOWEVER IT IS RECOMMENDED, IN
OUR OPINION. TO USE ONE OF THEM TO ASSIST IN
PREVENTING VARIABLE SHRINKAGE AND CRACKING.
3. THE PROPORTIONS APPROVED SHALL BE CAREFULLY
MAINTAINED. NO DEVIATION FROM THESE PROPORTIONS.
ESPECIALLY THE ADDITION OF WATER, SHALL BE MADE
WITHOUT APPROVAL OF THE ENGINEER.
13 MATERIAL - =ENT. WATER & AGGREGATES PER ACI 301
A. CEMENT MUST CONFORM TO ASTM 150, TYPE I OR TYPE II.
ENGINEER'S APPROVAL IS REQUIRED FOR USE OF TYPE III
CEMENT.
B. WATER TO BE CLEAN AND POTABLE.
C. COARSE AND FINE AGGREGATES TO CONFORM TO ASTM -C33
3.4 MATERIALS
A. WATER REDUCING ADMIXTURES: MUST CONFORM TO ASTM -C494,
POZZOLITH POLYHEED, POZZOLITH 100XR, OR POZZUTECH 20
POZZOLITH SHALL BE INCORPORATED INTO ALL CONCRETE IN
EXACT - ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS
CONCRETE USING POZZOLITH ADMIXTURES TO PRODUCE FLOWABLE
CONCRETE MAY BE USED WITH THE ENGINEER'S APPROVAL
ADMIXTURES AND DOSAGES WILL VARY DEPENDING ON CLIMATIC
CONDITIONS AND THE CONTRACTOR'S JOBSITE REQUIREMENTS.
MAXIMUM SLUMP FOR SUCH CONCRETE SHALL NOT EXCEED 8"
WITH A MINIMUM OF 10 OUNCES OF ROL:NEED PER 100 OUNCES
OF CEMENT. USE IN ACCORDANCE WITH MANUFACTURER'S
RECOMMENDATIONS.
B. AIR ENTRAINMENT: CONFORM TO ASTM -C260 AND ASTM -C494,
MBVR OR MICRO -AIR BY MASTER BUILDER. ENTRAIN 5% +/- 1%
AIR BY VOLUME IN ALL EXPOSED CONCRETE.
C. OTHER ADMIXTURE: NO OTHER ADMIXTURES PERMITTED UNLESS
PRIOR APPROVAL IS GIVEN BY THE ENGINEER.
sq- ..(09
3.5 REINFORCING STEEL
DETAIL. FABRICATE AND PLACE PER ACI -315 AND ACI -318.
SUPPORT REINFORCEMENT WI TH APPROVED CHAIRS. SPACERS, OR
TIES
D TRIM REINFORCING. AROUND ALL OPENINGS SHALL BE A
MINIMUM I - #5 TOP AND BOTTOM, EXTENDING 2' -6" BEYOND
OPENING AT EACH CORNER. SEE TYPICAL DETAILS.
F.
4.0 METALS
4.1 WELDING
5.0 MISCELLANEOUS
STEEL REINFORCEMENT SHALL BE NEW, DEFORMED BILLET
STE EL MEETING ASTM STANDARD "A" 615 -93; GRADE 60 FOR
# 3 AND LARGER BARS AR
SS NOTED OTHERWISE ON THE PLANS.
UNL E
SHOP DRAWINGS SHALL O ACCORDINGLY AND SUBMITTED
TO THE E ENGINEER FOR REVIEW PRIOR TO FABRICATION. A A. GRADE
TO REBARS RS SHALL NOT BE BENT IN FIELD D AFTER PLACING
REINFORCEMENT IN ALL WALLS. SLABS, AND FOOTINGS SHALL
BE CONTINUOUS AROUND CORNERS OR CORNER BARS PROVIDED,
BOTH VERTICAL AND HORIZONTAL.
LAPS. ALL TENSION SPLICES ARE ACCORDING TO ACI 318 -89,
CLASS B AND ALL COMPRESSION SPLICES ARE 30 DIAMETERS
FOR I'c GREATER THAN 3000 PSI AND ARE 40 DIAMETERS FOR
I'c WHICH IS LESS THAN 3000 PSI, UNLESS NOTED
OTHERWISE.
WELDING: TACK WELDING OF REBAR IS NOT PERMITTED UNLESS
CALLED FOR AND APPROVED BY THE ENGINEER
MINIMUM REINFORCING: WHERE REINFORCEMENT IS NOT SHOWN
ON THE DRAWINGS. THE "BUILDING CODE REQUIREMENTS FOR
REINFORCED CONCRETE "(ACI 318 -89) SHALL BE REFERRED TO
FOR PROPER REINFORCEMENT
G. REBAR COVER: PROVIDE CONCRETE PROTECTION FOR
REINFORCEMENT AS FOLLOWS
3" CONCRETE DEPOSITED AGAINST EARTH
2" CONCRETE DEPOSITED AGAINST FORMS BUT
EXPOSED TO EARTH
1 -1/2" MAIN REINFORCING IN BEAMS
I -1/2" TO TIES IN COLUMNS. AND TED REBAR IN
WALLS
I -1/2" FOR BARS IN SLABS ON GROUND
I' FOR BARS IN SLABS ON FORMS
H. WELDED WIRE FABRIC. ASTM -A185 AND ASTM -A82
I. DEFORMED BAR ANCHORS. ASTM -A496
3.6 INSPECTORS
CONCRETE INSPECTIONS SHALL BE FOLLOWED PER THE 1991 UBC
SECTIONS 305 AND 306 AND /OR AS REQUIRED BY THE LOCAL
BUILDING DEPARTMENT. THEY SHALL BE DONE BY AN INDEPENDENT
AGENCY EMPLOYED BY THE OWNER. JOBSITE VISITS BY THE
ENGINEER DO NOT CONSTITUTE AN OFFICIAL VISIT
ALL WELDING SHALL BE IN ACCORDANCE WITH THE "STRUCTURAL
WELDING CODE ", AWS D1.1.
B. ALL WELDING SHALL BE BY CERTIFIED WELDERS, USE E60 OR
E70 ELECTRODES.
C. NO WELDING OF REINFORCING STEEL SHALL BE ALLOWED EXCEPT
WHERE SHOWN
VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO PROCEEDING
PROVIDE ERECTION BRACING AS NECESSARY UNTIL PERMANENT
SUPPORT AND STIFFNESS ARE INSTALLED. REFER TO ARCHITECTURAL
PLANSFOR WALL OPENING. ARCHITECTURAL TREATMENT AND
DIMENSIONS NOT SHOWN. REFER TO MECHANICAL AND ELECTRICAL
PLANS FOR SIZE AND LOCATION OF ALL OPENINGS FOR DUCTS,
PIPES, CONDUITS, ETC., NOT SHOWN.
PANEL ELEVATION P -136
SCALE 1/4 " =1' -0"
TYP. REINF. PER STRUC T.
PLANS. #5 0 18" O.C.
HORIZ. #4 0 16" O.C.
VERT.
TS 4x4x1/4 STRONG
BACK W /5/8 "0x3 -1/2"
EMBED RAW_ "FOIL FAST"
ADHESIVE ANCHOR 0
24" O.C. MAX. (6" FROM
TOP & BOT. OF PANEL
2' 0" WIDE PORTION OF
PANEL TO BE REMOVED
PROVIDE FINISH PER
OWNER
#4 YP) COAT. 0 BOUNDARY
(T
5 1/2" CONE PANEL (2500
PSI MIN. CONC.)
AI,el dab rson Povt®rt
CONC. WALL TO BE
ABANDONED
6 "0 STD. PIPE
BOLLARD. FILL W/
CONC. EMBED 24"
8
0.00'
2' -0" TO BE REMOVED
2' -3 "OF WALL TO REMAIN
EXISTING BUILDING #783
SHADING INDICATES EXIST
SLAB ON GRADE / DOCK
LEVELER TO BE REMOVED
T.O.
VARIES
24" PORTION OF
EXIST. TILT UP
WALL TO BE
REMOVED
6" SLAB ON GRADE W/
#4 0 14" O.C. EA. WAY
.-- 10" THICK x 3' -6" WIDE
FTC.
6" CONE. WALL
PARTIAL SITE PLAN
SCALE 1 /8 ° =1' -O"
-- EXISTING STRUCTURE
(PRE -CAST TILT UP
WALLS)
Structural ErLair#.eerina Consultants
CRY OF TUKWILA
APPROVED
APR 2 4 1996
AS NOTED
BUILDING DIVi31011
T RECEIVED
CI OF TUKVIIIA
PERMIT CENTER
CC
0.
N
W
_Z
N
3
W
W
N
z
0
I-
0
z
N
-I
3
UT
0
CO
Ol
C
N
c
SUBMITTAL SET ONLY
NOT FOR CONSTRUCTION
NEM COM.. ARE SUBJECT TO
ICNOINS PFAGNG LOCAL JURISOCPOMAL
REVIEW
Si
> I-
.
N3
W�
50
�2,4
DIA. (15" MIN.)
TYP. ALL CORNER
BARS AND SPLICES
PLACE ALTERNATING
CORNER BARS AS
SHOWN
2 "MIN. - 6
MAX. (TYP)
BIN. 180' HOOK
LAP 24 DIA. W/
HORIZ. REINF
'CSR
I: s .
TYPICAL
ACI MIN. CLEAR + 1/2" MAX
REINFORCEMENT PLACING
NOTESI
1 VERTICAL REINF. SHOWN IS ADDED IF NORMAL
WALL REINF. IS NOT IN PROPER LOCATIONS
2. CORNER BARS ARE SAME SIZE AND SPACING
AS HORIZ. REINF.
3. 90' HOOKS MAY BE SUBSTITUTED FOR
CORNER BARS (SEE NOTE 5).
4. REINF. AT ALL WALL CORNERS, ENDS AND
INTERSECTIONS SHALL BE FABRICATED AND
PLACED IN ACCORDANCE WITH APPROPRIATE
DETAIL SHOWN.
5. USE ACI MIN. 90' HOOK FOR EMBEDMENT
LESS THAN 24 DIAMETERS PAST FACE OF
WALL.
6. CONCRETE WALLS SHOWN; MASONRY WALLS
SIMILAR.
7. WALL DETAILS SHOWN, FIG. DETAILS SIMILAR.
8. VARIOUS WALL SECTIONS AND INTERSECTIONS
SHOWN; USE APPROPRIATE DETAILS.
DIAGRAM
OPTION /1 CONDUIT PASSES BELOW FIG
TOP OF FOG.
(
7 EXISTING TRENCH
NOTE: IF CONDUIT 0 SAME S • FOR CONDUIT
ELEV. AS WALL FTC., STEP x S 1`
D
•
OWN TO ALLOW CONDUIT 5111111
TO PASS THRU WALL PER
THE TYPICAL STEPPED FTC.
DETAIL
OPTION /2 CONDUIT PASSES RU WALL
CONC. WALL 4
4' -0" MAX
WALL FAG. WILL
ADEOUETLY
SPAN 4' -0"
#4 TRIM BARS
AROUND OPENING
(EA. SIDE & S 45')
24 "x24" MAX.
OPENING
TOP OF FIG.
) TYP. CONDUIT INTERSECTION
AT OWNERS OPTION
PROVIDE #4 NOSE
BARS FOR CRACK
CONTROL
#4 REINF. TO STOP SLAB ON GRADE PER
0 CONTROL JOINT DET. 1/51 (SLOPE PER
PLAN)
CONTROL JOINT @ SLAB ON GRADE
CONTROL JOINT 0
20' -0" O.C. MAX.
(LOCATE PER OWNER)
STOP REINF
0 JOINT
WIDTH OF WALL
CONTROL JOINT @ WALL
CONTROL JOINTS
- AT OWNER OPTION
PROVIDE D
SMOOTH SURFACE FOR
RAMP SLOPE TRANSITION
1/2" DEEP CHAMFER
MIN. DIM. TO BE
SAME AS FTC.
THICKNESS
_J TYPICAL STEPPED FOOTING
REINF. TO BE SAME AS
LONGITUDINAL BARS. _
PROVIDE MIN. 24" LAP
W/ LONGITUDINAL REINF.
FIG
THICKNESS
CNC 104
EXIST, TILT UP WALL �\ I
PANEL BEYOND \ I
(2)- LAYERS OF 30#
FELT FOR SLAB ISOL.
& PROTECTION OF
EXIST. STRUCTURE
EXIST. CONC WALL
FELT PROTECTION
BOARD PER OWNER
AGAINST EXIST. CONC.
STRUCTURE
�V 1
MC10x8.4 W / #4 WELTMENTS
x 24" MIN. 0 14" O.C.
NEW PORTION OF 6"
SLAB ON GRADE 0
INT. W /#4 0 14" O.C.
EA. WAY 0 fL DOWEL
INTO EXIST SLAB
DOCK LEVELER TO BE
REMOVED
_J NEW SLAB TO EXISTING SLAB
1/2" REVEAL
PER OWNER
PROVIDE VERTICAL
WALL CONTROL
JOINTS PER DET.
4 /St
H PLACE REINF. PER
I. DET. 6 /51
STEP FIG'S AS LEO.
PER DET 3/01
RECOMPACTES
GRADE / NEW
ASPHALT IN
FRONT OF WALL
ADD'L #4 FOR
STEM REINF.
PLACING
PROVIDE #4 x 24" CORNER REINF.
0 FTC. & WALL
CORNERS
1" CHAMFER PER OWNER
30# FELT FOR SLAB ISOLATION
6" SLAB ON GRADE W/ #4 0
14" O.C. EA. WAY 0
4" TO 6" OF COMPACTED
GRAVEL BASE 1-"
2 6
(12" WHERE SLAB HEIGHT
IS LESS THAN 24" ABOVE
FINISHED GRADE IN FRONT
OFF WALL)
TYPICAL @ RAMP WALLS
WELL COMPACTED SUB -BASE
#4 x I= 0 10" O.C. (16" O.C.
WHERE SLAB HT. IS
LESS THAN 24" ABOVE
12' FINISHED GRADE)
#4 0 16" O.C. CONT. HORIZ.
4 "0 PERT PVC DRAIN TO
yr DAYLIGHT (OR 2 "0 WEEP HOLES
THOU WALL 0 48" 0.C.) PROVIDE
12" STRIP FREE DRAINING MAT'L
0 BACK FACE OF WALL (NOT
SHOWN)
#4 0 10" O.C. HEEL REINF.
- 2" CLR.
#4012" O.0
CON T.
STRUCTURAL NOTES
1.0 GENERAL
1.1 CODES
THESE STRUCTURAL NOTES SUPPLEMENT THE SPECIFICATIONS, ANY
DISCREPANCY FOUND AMONG THE DRAWINGS, SPECIFICATIONS,
THESE NOTES, AND THE SITE CONDITIONS SHALL BE REPORTED TO
THE ARCHITECT, WHO SHALL CORRECT SUCH DISCREPANCY IN
WRITING. ANY WORK DONE BY THE CONTRACTOR AFTER DISCOVERY
OF SUCH DISCREPANCY SHALL BE DONE AT THE CONTRACTOR'S RISK.
THE CONTRACTOR SHALL VERIFY AND COORDINATE WI THE DIMENSIONS
AMONG ALL ONC ALL DRAWINGS PRIOR TO PROCEEEDING ING WITH ANY WORK OR
ANDRICATION, THE CONTRACTOR IS IS RESPONSIBLE -FOR ALL BRACING
AND SHORING DURING CONSTRUCTION,
ALL METHODS, MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE
REQUIREMENTS OF THE CITY OF TUKWILA AND: THE 1994 UNIFORM
BUILDING CODE (UBC), AS AMENDED AND ADOPTED BY THE CITY OF
TUKWLA AND THE STATE OF WASHINGTON: A.C.I. 318 -89 (REVISED
1992): A.I.S.C. 9TH EDITION. A.I.T.C. 2ND EDITION; AND
A. I.S.I 1986 EDITION AND 1989 ADDENDUM.
1.2 DESIGN CRITERIA
A. VERTICAL LOADS
1. LIVE LOADS
LIGHT COMMERCIAL VEHICLE TRAFFIC 200 PSF
1.3 SOIL DATA
VALUES ARE ASSUMED AND ARE TO BE FIELD VERIFIED, SOIL
BEARING 0 CONT. SPREAD FOOTINGS = 2000 PSF. EQUIVALENT
FLUID ACTIVE PRESSURE AND PASSIVE PRESSURE ARE ASSUMED TO BE
35 PSF AND 350 PSE. RESPECTIVELY. SOIL UNIT WEIGHT IS
ASSUMED TO BE 120 PCF AND THE SLIDING COEFFICIENT IS ASSUMED
TO BE 0.50.
2.0 STE NO I(
2.1 EXCAVATION
EXCAVATE FOR FOOTINGS DOWN TO DEPTH SHOWN ON DRAWINGS OR TO
FIRM UNDISTURBED MATERIAL. AREAS OVER- EXCAVATED SHALL BE
BACKFILLED WITH LEAN CONCRETE (Yc = 2000 PSI), OR BE
STRUCTURALLY FILLED PER SECTION 2.2 AND SHALL BE AT THE
CONTRACTOR'S EXPENSE
2.2 BACNFlLL MID COMPACTION
BACKFILL SHALL NOT BE PLACED UNTIL AFTER THE REMOVAL OF ALL
FORMS. SCREEDS, OTHER WOOD DEBRIS AND MATERIAL SUBJECT TO
ROT OR CORROSION. USE ONLY MATERIALS APPROVED FOR BACKFILL.
IN AREAS UNDER SLABS OR FOOTINGS, MATERIAL SHOULD BE
GRANULAR IN NATURE. PLACED IN 6 -INCH LIFTS AND COMPACTED TO
AT LEAST 95% OF MAXIMUM DRY DENSITY AS DETERMINED BY AASHTO
COMPACTOR TEST. PROCEDURE T -180. THE FILL SHOULD BE
LIMITED TO CLEAN. GRANULAR MATERIAL.
3.0 CONCRETE
3.1 GENERAL
NORMAL WEIGHT CONCRETE MEETING THE REQUIREMENTS OF ACI 301-
89 ESTABUSH PROPORTIONS OF CEMENT, COURSE AND FINE
AGGREGATES, WATER. AND ADMIXTURES TO PRODUCE THE PROPERTIES
SPECIFIED FOR EACH CONCRETE MIX TYPE PER ACI -301 ON THE
BASIS OF PREVIOUS VIOUS FIELD EXPERIENCE OR. TRAIL BATCHES. A
E
WATER PR ADMIXTURE RE 500 IN ALL CONCRETE SIXES
FOR THIS IS PROJECT. CONCRETE N ALL ANDTE TB 50 PSI AND OVER SHALL
INCLUDE A SUPERPLASTICIZER ER AND BE FLOWABLE N TO INCH
SLUMP). USE ADMIXTURES CCORDAANCE E WIT- H THE
MANUFACTURER'S DIRECTIONS. CI RECTO PE. . USE AMOUNTS OF WATER- REDUCING
ADMIXTURE THAT WILL PERMIT PLACING T WITHOUT FON,
HONEYCOMBING R ROCK POCKETS. THE ITE SL OFUMP SPECIFIED SPECIFIED LED ARE THE
SLUMPS REQUIRED IEED RT THE POINT T
OF PLACEMENT INTO THE
STRUCTURE. U U N INTERIOR MECHANICAL COS WITH RPM
MINIMUM FRR USE DO NOT OVER-VIBRATE. SHALL CONCRETE SH C BE
PINOUS MONCTTA FRE BETWEEN CONSTRUCTION OR CONTROL
JOINTS. PROTECT ALL LL AL FRESHLY PLACED CONCRETE FROM PREMATURE
AF AND EXCESSIVE HOT COLD TEMPERATURES FOR SUN DAYS
AFTER TER POURINING. . PROVIDE ENGINEER FERR WITH PROPOSED CONSTRUCTION
OR CONTROL JOINT LOCATORS FOR HIS APPROVAL, L, OR SHALL JOINTS
AS SHOWS WN TH
ON THE DRAWIRAWINGS. GS. RS ALL RS AND ANCHORS CUT
OFF FLUSH WITH THE FROM SURFACES WHERE ARACES WCONE EXPOSED S ESLL
EE DMEDTH AND FREE IR E SLAM IOREERLTRITIES. SONDUIRS & S & PIPES
WITHIN THIN THE SLAB (OTHER THAN THOSE MERELY PASSING
THROUGH) SHALL SATISFY THE FOLLOWING:
12 STRENGTH
1. THEY SHALL BE NOT LARGER THAN ONE THIRD THE
OVERALL THICKNESS OF THE SLAB IN WHICH THEY ARE
EMBEDDED.
2. THEY SHALL BE SPACED NOT CLOSER THAN THREE
DIAMETERS OR WIDTHS ON CENTER. AT ELECTRICAL
ROOMS OR CONGESTED AREAS WHERE MINIMUM SPACING
CANNOT BE ACHIEVED. USE #6 AT 12" O.C. EACH WAY
EXTENDING A MINIMUM OF TWO FEET BEYOND CONGESTION.
MORE THAN ONE LAYER OF CONDUIT IS NOT PERMITTED
UNLESS APPROVED BY THE ENGINEER.
3. THEY SHALL NOT IMPAIR SIGNIFICANTLY THE STRENGTH
OF CONSTRUCTION.
4. THEY ARE NOT EXPOSED TO RUSTING OR OTHER
DETERIORATION.
5. THEY ARE OF UNCOATED OR GALVANIZED IRON OR STEEL
NOT THINNER THAN STANDARD SCHEDULE 40 STEEL PIPE.
DESIGN MIXES TO PROVIDE NORMAL WEIGHT CONCRETE WITH THE
FOLLOWING PROPERTIES:
APPLICATION STRENGTH MAXIMUM MAXIMUM
F'c WATER /CEMENT SLUMP
(PSI) RATIO (INCHES)
ALL CONCRETE 2500 0.46 4
SUBNOTES:
ANY OF THE ABOVE MIXES CAN BE USED FLOWABLE (8" TO
11" SLUMP) IF THE PROPER ADDITION OF ADMIXTURES IS
INCLUDED AND THE W/C RATIO IS NOT INCREASED.
2. NON- STRUCTURAL CONCRETE SUCH AS SLABS ON GRADE MAY
OR MAY NOT CONTAIN WELDED -WIRE FABRIC PER SECTION
3.55 OR FIBER -MESH. HOWEVER IT IS RECOMMENDED, IN
OUR OPINION. TO USE ONE OF THEM TO ASSIST IN
PREVENTING VARIABLE SHRINKAGE AND CRACKING.
3. THE PROPORTIONS APPROVED SHALL BE CAREFULLY
MAINTAINED. NO DEVIATION FROM THESE PROPORTIONS.
ESPECIALLY THE ADDITION OF WATER, SHALL BE MADE
WITHOUT APPROVAL OF THE ENGINEER.
13 MATERIAL - =ENT. WATER & AGGREGATES PER ACI 301
A. CEMENT MUST CONFORM TO ASTM 150, TYPE I OR TYPE II.
ENGINEER'S APPROVAL IS REQUIRED FOR USE OF TYPE III
CEMENT.
B. WATER TO BE CLEAN AND POTABLE.
C. COARSE AND FINE AGGREGATES TO CONFORM TO ASTM -C33
3.4 MATERIALS
A. WATER REDUCING ADMIXTURES: MUST CONFORM TO ASTM -C494,
POZZOLITH POLYHEED, POZZOLITH 100XR, OR POZZUTECH 20
POZZOLITH SHALL BE INCORPORATED INTO ALL CONCRETE IN
EXACT - ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS
CONCRETE USING POZZOLITH ADMIXTURES TO PRODUCE FLOWABLE
CONCRETE MAY BE USED WITH THE ENGINEER'S APPROVAL
ADMIXTURES AND DOSAGES WILL VARY DEPENDING ON CLIMATIC
CONDITIONS AND THE CONTRACTOR'S JOBSITE REQUIREMENTS.
MAXIMUM SLUMP FOR SUCH CONCRETE SHALL NOT EXCEED 8"
WITH A MINIMUM OF 10 OUNCES OF ROL:NEED PER 100 OUNCES
OF CEMENT. USE IN ACCORDANCE WITH MANUFACTURER'S
RECOMMENDATIONS.
B. AIR ENTRAINMENT: CONFORM TO ASTM -C260 AND ASTM -C494,
MBVR OR MICRO -AIR BY MASTER BUILDER. ENTRAIN 5% +/- 1%
AIR BY VOLUME IN ALL EXPOSED CONCRETE.
C. OTHER ADMIXTURE: NO OTHER ADMIXTURES PERMITTED UNLESS
PRIOR APPROVAL IS GIVEN BY THE ENGINEER.
sq- ..(09
3.5 REINFORCING STEEL
DETAIL. FABRICATE AND PLACE PER ACI -315 AND ACI -318.
SUPPORT REINFORCEMENT WI TH APPROVED CHAIRS. SPACERS, OR
TIES
D TRIM REINFORCING. AROUND ALL OPENINGS SHALL BE A
MINIMUM I - #5 TOP AND BOTTOM, EXTENDING 2' -6" BEYOND
OPENING AT EACH CORNER. SEE TYPICAL DETAILS.
F.
4.0 METALS
4.1 WELDING
5.0 MISCELLANEOUS
STEEL REINFORCEMENT SHALL BE NEW, DEFORMED BILLET
STE EL MEETING ASTM STANDARD "A" 615 -93; GRADE 60 FOR
# 3 AND LARGER BARS AR
SS NOTED OTHERWISE ON THE PLANS.
UNL E
SHOP DRAWINGS SHALL O ACCORDINGLY AND SUBMITTED
TO THE E ENGINEER FOR REVIEW PRIOR TO FABRICATION. A A. GRADE
TO REBARS RS SHALL NOT BE BENT IN FIELD D AFTER PLACING
REINFORCEMENT IN ALL WALLS. SLABS, AND FOOTINGS SHALL
BE CONTINUOUS AROUND CORNERS OR CORNER BARS PROVIDED,
BOTH VERTICAL AND HORIZONTAL.
LAPS. ALL TENSION SPLICES ARE ACCORDING TO ACI 318 -89,
CLASS B AND ALL COMPRESSION SPLICES ARE 30 DIAMETERS
FOR I'c GREATER THAN 3000 PSI AND ARE 40 DIAMETERS FOR
I'c WHICH IS LESS THAN 3000 PSI, UNLESS NOTED
OTHERWISE.
WELDING: TACK WELDING OF REBAR IS NOT PERMITTED UNLESS
CALLED FOR AND APPROVED BY THE ENGINEER
MINIMUM REINFORCING: WHERE REINFORCEMENT IS NOT SHOWN
ON THE DRAWINGS. THE "BUILDING CODE REQUIREMENTS FOR
REINFORCED CONCRETE "(ACI 318 -89) SHALL BE REFERRED TO
FOR PROPER REINFORCEMENT
G. REBAR COVER: PROVIDE CONCRETE PROTECTION FOR
REINFORCEMENT AS FOLLOWS
3" CONCRETE DEPOSITED AGAINST EARTH
2" CONCRETE DEPOSITED AGAINST FORMS BUT
EXPOSED TO EARTH
1 -1/2" MAIN REINFORCING IN BEAMS
I -1/2" TO TIES IN COLUMNS. AND TED REBAR IN
WALLS
I -1/2" FOR BARS IN SLABS ON GROUND
I' FOR BARS IN SLABS ON FORMS
H. WELDED WIRE FABRIC. ASTM -A185 AND ASTM -A82
I. DEFORMED BAR ANCHORS. ASTM -A496
3.6 INSPECTORS
CONCRETE INSPECTIONS SHALL BE FOLLOWED PER THE 1991 UBC
SECTIONS 305 AND 306 AND /OR AS REQUIRED BY THE LOCAL
BUILDING DEPARTMENT. THEY SHALL BE DONE BY AN INDEPENDENT
AGENCY EMPLOYED BY THE OWNER. JOBSITE VISITS BY THE
ENGINEER DO NOT CONSTITUTE AN OFFICIAL VISIT
ALL WELDING SHALL BE IN ACCORDANCE WITH THE "STRUCTURAL
WELDING CODE ", AWS D1.1.
B. ALL WELDING SHALL BE BY CERTIFIED WELDERS, USE E60 OR
E70 ELECTRODES.
C. NO WELDING OF REINFORCING STEEL SHALL BE ALLOWED EXCEPT
WHERE SHOWN
VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO PROCEEDING
PROVIDE ERECTION BRACING AS NECESSARY UNTIL PERMANENT
SUPPORT AND STIFFNESS ARE INSTALLED. REFER TO ARCHITECTURAL
PLANSFOR WALL OPENING. ARCHITECTURAL TREATMENT AND
DIMENSIONS NOT SHOWN. REFER TO MECHANICAL AND ELECTRICAL
PLANS FOR SIZE AND LOCATION OF ALL OPENINGS FOR DUCTS,
PIPES, CONDUITS, ETC., NOT SHOWN.
PANEL ELEVATION P -136
SCALE 1/4 " =1' -0"
TYP. REINF. PER STRUC T.
PLANS. #5 0 18" O.C.
HORIZ. #4 0 16" O.C.
VERT.
TS 4x4x1/4 STRONG
BACK W /5/8 "0x3 -1/2"
EMBED RAW_ "FOIL FAST"
ADHESIVE ANCHOR 0
24" O.C. MAX. (6" FROM
TOP & BOT. OF PANEL
2' 0" WIDE PORTION OF
PANEL TO BE REMOVED
PROVIDE FINISH PER
OWNER
#4 YP) COAT. 0 BOUNDARY
(T
5 1/2" CONE PANEL (2500
PSI MIN. CONC.)
AI,el dab rson Povt®rt
CONC. WALL TO BE
ABANDONED
6 "0 STD. PIPE
BOLLARD. FILL W/
CONC. EMBED 24"
8
0.00'
2' -0" TO BE REMOVED
2' -3 "OF WALL TO REMAIN
EXISTING BUILDING #783
SHADING INDICATES EXIST
SLAB ON GRADE / DOCK
LEVELER TO BE REMOVED
T.O.
VARIES
24" PORTION OF
EXIST. TILT UP
WALL TO BE
REMOVED
6" SLAB ON GRADE W/
#4 0 14" O.C. EA. WAY
.-- 10" THICK x 3' -6" WIDE
FTC.
6" CONE. WALL
PARTIAL SITE PLAN
SCALE 1 /8 ° =1' -O"
-- EXISTING STRUCTURE
(PRE -CAST TILT UP
WALLS)
Structural ErLair#.eerina Consultants
CRY OF TUKWILA
APPROVED
APR 2 4 1996
AS NOTED
BUILDING DIVi31011
T RECEIVED
CI OF TUKVIIIA
PERMIT CENTER
CC
0.
N
W
_Z
N
3
W
W
N
z
0
I-
0
z
N
-I
3
UT
0
CO
Ol
C
N
c
SUBMITTAL SET ONLY
NOT FOR CONSTRUCTION
NEM COM.. ARE SUBJECT TO
ICNOINS PFAGNG LOCAL JURISOCPOMAL
REVIEW
Si
> I-
.
N3
W�
50
;. WALL
?500 PSI
ANGLE
. WALL
8' OV
\ 5
6" CON
F'C
3" CURB
5 1/2" CON
REAR PIT DEPTH AT 23 1/2"
FRONT PIT DEPTH AT 24"
1
6" CONC. SLAB
#4 REBAR t0 12" O.C. EACH WAY
6" CONC. SLAB
DOCKLEVELER FLOOR PLAN
DOCKLEVELER PIT ELEVATION
RHEAD DOOR
8' WIDE DOOR
3" CURB ANGLE
5 1/2" CONCRETE FLOOR
CAD FILE: LEVELOR
CITY OF TURI:IU
APPROVED
APR 2 4 1996
BUILDING DIVISION
SEGALE
BUSINESS PARK
TUKWILA, WASHINGTON 50) ne-�ao
BUILDING 763
LENIHAN DIST
18200 SBP 'B'
umom
bur be
a b
3/4 " =1' —O" 01 -30 -96
COMM MAMMt
1
RECEIVED
TERMR CENTER
rrorcr KUM:
IRON CR
SO. I 0: 1