Loading...
HomeMy WebLinkAboutPermit B96-0074 - UNION TANK WORKS - FIRE ESCAPECity of Tukwila (_, jx (206) 431-3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 BUILDING PERMIT Permit No: B96 -0074 Type: B -BLDG Category: ACOM Address: 12065 44 PL S St: 01 Location: Parcel #: 334740 -1330 Zoning: M2 KR315E 102304 Type Const: III -N Gas /Elec: Wetlands: Water: TUKWILA Contractor License No.: Status: ISSUED Issued: 04/26/1996 Expires: 10/23/1996 Type of Occupancy: OFFICE Siopes: N Sewer: SEATTLE TENANT UNION TANK WORKS 12065 44 PL S, TUKWILA WA 98178 OWNER UNION TANK WORKS INC PO BOX 53186, BELLEVUE WA 98015 CONTACT WILLIAM OCONNELL PO BOX 941,'BELLEVUE :WA',98009 Phone: (206)762 -5500 Phone: 454 -4117 *•k k * ** *•k ** * * * * * ** * * * * * * * ** *** * ******** ******'*** *****•****•k **** *"k********* *** Permit Descr ip.tion :. EXTENEY2r1RE ESCAPE FROM SECOND':. FLOOR TO GROUND AT THE REQUEST OF "THE FIRE: DEPARTMENT. Units: 001 Buildings: 001` Fire Protection: N/A UBC Edition: '1994.,' SETBACKS Front: .0 Back: Left: .0 Right:. .0 Valuation: 1,000.00 Total Permit Fee: 61.84 k* k k * *k * ** ***• k * * * * * *•k ** * * * ** * * * * * * * *•k *** k ** * * * ** k k * * * * ** *ii * *•k * * * * * * * * * * * ** L{—Q— PermitYCenter: Authorized Signature Date I hereby. certify that I have read and examined this permit and know the same tobe true and correct. All provisions of law and ordinances governing,this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other. state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this bu "ld'ng�• Signature: Date: 2-C &J Print Name:14'L'S y_.,� � _y y_t�(,.�t _ T it1e :1/ Lb This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. DEPARTMENT-, DATE IN DATE , APPROVED . . REQUIREMENTS '/ COMMENTS )4;; Plan Review Meeting ? 21_ 3 "a- 9 U 2nd NOTIFICATION INIT: L 3)t .- (X BUILDING - initial review ( CONSULTANT: Date Sent - Date Approved - Gi RO E V D) ) FIRE Li 10462 FIREPROTECTION: O Sprinklers ❑ Detectors ON/A FIREDEPT.LErTERDATED: INSPECTOR: �1 I '� / — OPLANNING ' k1 A AC-1 ZONING: PAR /LANDUSECONDITIONS? OYes ❑ No 1 1EFERENCEFILENOS.: INIT: MINIMUMSETBACKS: N- S- E- W- O PUBLIC WORKS 6 � 3-) JTILITYPERMITSREQUIRED? O Yes ❑ No �UBLICWORKS LETTER DATED: INIT: ' (BUILDING - final review ,..1./ D a � TYPEOFCONSTR;." - 1\. CS' V-) CERT.OFOCCUPANCY? [Yes , ®1‘o UBC EDITION (year): 1 c cr INI : ((- --‘. BUILDING OFFICIAL U I t o c > `�%/<j7 j C2 INIT: AMOUNT OWING: Q x x 1 CONTACTED - Et O (init.) ►�1� DATE NOTIFIED I A- t r _ GE (9 ''1 2nd NOTIFICATION BY: (init.) 3RD NOTIFICATION BY: (init.) PLAN CHECK NUMBER CITY OF TUKWILA Department of Comm&nty Development — Permit Center 6300 Southcenter Boulevard - #100, Tukwila, WA 98188 (206) 431 -3670 Building Permit Application Tracking PROJECT NAME (fN10N * SITE ADDRESS 12VDS 1- PL INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that the status of the project may be ascertained at any time. • Plan corrections shall be completed and approved prior to sending to the next department. • Any conditions or requirements for the permit shall be noted in the Sierra system or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N/A ", date and initial. DEPARTMENTAL REVIEW "X" in box indicates which departments need to review the project. SUITE NO. REVIEW COMPLETED 02/15196 SITE ADDRESS SUITE 4 12065 44th Place South VALUE OF CONSTRUCTION - $ $1,000 PROJECT NAME/TENANT UN on --da (1JOY l Fire Escape Improvement ASSESSOR ACCOUNT # �� �� 053 (commercial) U Demolition (building) 0 Other TYPE OF 0 New Building U Addition (x) Tenant Improvement WORK: 0 Rack Storage 0 Reroof 0 Remodel (residential)_ DESCRIBE WORK TO BE DONE: Extend fire escape from 2nd floor to ground (exterior) at the recomendation of the Fire Department. BUILDING USE (office, warehouse, etc.) Office, 2 story NATURE OF BUSINESS. ' General office / administration WILL THERE BE A CHANGE IN USE? © No 0 Yes If Yes, new building requirements may need to be met. Please explain: SQUARE FOOTAGE - Building:4000 Tenant Space: Area of Construction: WILL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING? Q No 0 Yes IF YES, EXPLAIN: FIRE PROTECTION FEATURES: 0 Sprinklers CO Automatic Fire Alarm System PROPERTY OWNER Union Tank Works, Inc I PHONE 762.5500 ADDRESS 12065 44th Place South ZIP 98178 CONTRACTOR Uni on Tank Works, Tnr• PHONE 762 5500 ZIP ADDRESS Same WA. ST. CONTRACTOR'S LICENSE # See Affidavit EXP. DATE ARCHITECT PHONE ADDRESS 'ZIP 1 HEREBY CERTIFY THAT I HAVE AND :: EXAMINED. THIS:APPLICATION;AND:KNOW THE SAME TO BE TRUE AND • CORRECT, AND I AM. AUTHORIZED TO `APPLY FOR THIS PERMIT- ': BUILDING OWNER OR AUTHORIZED AGENT SIGNATURE (, /- � .:∎ PGL � DATE 18Mar9• PRINT NAME William T, O ' rnnnel1, 4th PHONE 4 15 4 1.4117 CITY2IP ADDRESS p0 Box 941 Bellevue WA 98009 CONTACT PERSON k �, t2t�1 .' c Clan I I PHONE Chu _ (,{' I� urcwna vvH yo i acs DESCRIPTION AMOUNT RCPT # . . DATE BUILDING PERMIT FEE 11 ;' PLAN CHECK FEE1 z S T BE 'LETELY BUILDING SURCHARGE : O (: OTHER: TOTAL - i 101-g1 CITY OF TUKWILA Department of Community Development - Building Division 6300 Southcenter Boulevard, (206) 431 -3670 APPLICATION MU FILLED OUT COM PLAN CHECK NUMBER DATE APPLICATION ACCEPTED BUILDING. PERMIT APPLICATION APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. Handouts are available at the Building counter which provide more detailed information on application and plan submittal requirements. Application and plans must be complete in order to be accepted for plan review. VALUATION OF CONSTRUCTION Valuation for new construction and additions are calculated by the Department of Community Development prior to application submittal. Contact the Permit Coordinator at 431 -3670 prior to submitting application. In all cases, a valuation amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Building Division to comply with current fee schedules. BUILDING OWNER / AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitations. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Building Code (current edition). No application shall be extended more than once. If you have any questions about our process or plan submittal requirements, please contact the Department of Community Det lopment,pyilding Division at 431 -3670. M R 2 iAli CATION EXPIRES 9L0,41_ GL.iv t Fi is ;OMMERCIAL JEW COMMERCIAL BUILDINGS /ADDITIONS I Completed building permit application (one for each structure) — I Assessor Account Number Two sets (2) of the following: .1 Specifications Structural calculations stamped by a Washington State licensed engineer Soils report stamped by a Washington State licensed engineer Topographical survey. — 1 Energy calculations stamped by a Washington State licensed engineer or architect -1 Legal description Working drawings, stamped by a Washington State licensed architect, which include: • Site plan • Architectural drawings • Structural drawings • Mechanical drawings • Elevations • Civil drawings • Landscape plan i Completed utility permit application (one for entire project) I I Six (6) sets of civil drawings NOTE: See utility permit application and checklist for specific utility submittal requirements. RACK STORAGE Completed building permit application , I Assessor Account Number Two (2) sets of plans, which include:. 7 Building floor plan showing: • Entire space where racks will be located • Exit doors • Dimensions of all aisles Tenant space floor plan showing rack storage layout, aisles and exits. NOTE: include dimensions of racks (height, width and length), aisles and exit ways on plan. !i Structural calculations stamped by a Washington State licensed engineer (rack storage 8' and over). RESIDENTIAL NEW SINGLE - FAMILY DWELLINGS /ADDITIONS I I Completed building permit application (one for each structure) I Legal description Assessor Account Number Two sets (2) of working drawings, which include: • Site pan .- --._,y (On plan, show closest hydrant location. • roundation plan Include access to Waling, showy • Floor plan width and length of access.) • Roof plan • Building elevations (all views) • Building cross - section • Structural framing plans i Washington State Energy Code data I SUBMITTAL CHECKLI8T Completed utility permit application [J Six (6) sets of site plans showing utilities NOTE: Building site plan and utility site plan may be combined. See utility permit application and checklist for specific submittal requirements. Additional topographical and soils information may be required if unique site conditions. COMMERCIAL TENANT IMPROVEMENTS n C ompleted building permit application (one for each structure or tenant) Assessor Account Number Two (2) sets of construction plans, which include: I Site plan • Location of tenant space • Existing and proposed parking ::: • • Landscape plan (if applicable, i.e., change of use Overall uuilding plan • Tenant location • Use of adjacent (common wall) tenant • Overall dimensions of building or square footage Floor plan of proposed tenant space • Tenant space plan with use of each room labelled. •:Exit doors, egress patterns • New walls, existing wall, and walls to be demolished n C • onstruction details •:Cross sections showing wall construction and method of attachment for floor and ceiling. Structural calculations stamped by a Washington State licensed engineer may be required if structural work is to be done (2 sets) NOTE: If any utility work is to be done, submit separate utility permit :: application and plans. REROOF n C • ompleted building permit application (one for each structure) ..J Assessor Account Number Narrative describing existing roof, material being removed, and material being installed. NOTE: 'A certification letter is required prior to final inspection and sign - off of the permit. ANTENNA/SATELLITE DISHES � Completed building permit application Assessor Account Number Two (2) sets of plans, which include: Site Plan (showing building and location of antenna/satellite dish) • Details antenna/satellite dish and method of attachment. Structural calculations stamped by a Washington State licensed engineer may be required RESIDENTIAL REMODELS Li Completed building permit application (one for each structure) Assessor Account Number Two (2) sets of working drawings, which include: • Site plan Foundation plan • Floor plan • Building elevations (all views) • Building cross - section • • Structural framing plans NOTE: If any utility work is to be done provide utility permit application and plans must be submitted REROOFS I-1 Completed building permit application (one for each structuie) E AssessorAccount Number Narrative describing existing roof, material being removed, and material being installed.. NOTE: A certification letter is required prior to final inspection and sign- off of the permit. Address: 12065 44 PL S St: 01 Suite: Tenant: UNION TANK WORKS Type: B-BLOG Parcel 334740-1330 **41r4i4 lib4 c4 c4 ******4/4411141144A***444 4lew*4464.44444*4**4 . Permit Conditions: 1. No changes will be made to the plans unless approved by the Architect 'or Engineer andth#:-.)"(a,:w0aBuildiro? 2, All permits, inspectione.6o0w plans shall be available at thelobs-ite to the-sta,rt, of any con- struction. These-,d6cuments:are ti,be maintained and avail- able until fAnaT,'Hnspe,ctiOn'app! is 3 All construcin to be done in conformance:with apOroved plans anC-requirements *Of the,Uniform EvildingCode' (1994 Edition aifended';' at; 4. Validi PerMit. .The issuah.ce at a Permlt Pr of planspeciffcations, and computations shall not be con-' struOi o,:bt a permit for„ pr an approval of, 'any vio.atioh of of the provisiOps''Of the buildinQ code or of any oth,et;fordlnance of the juriidiction. No permit p: to qi..ieauthiSi!,ityto violate oi-. the provisions of this: code,:"shall.. Gli OF 'TUKWILA • Permit No: E96-0674 Status: ISSUET Applied: 03121/1996 Issued: 0412611996 GENERA 34.75 hk• k*%* k• kAh: kd•• kh k:kAk•A•k•A*Aa *h:lk**khkkkk:tk: • *A*kdtt4*k *A*AAA *AkA * * GENERA 22.59 TRANSMIT GENERA 4.50 * f.•: kh A*4* AA4*A** kA: tA: 4***A*• A• k* Ak{ e• k• k• k• t•h Afe: kk AAkkAk:t•kAkk•t•k•4 **A-•k:t TOTAL 61.84 'i RF►NSHIT Number: 96003839 Amount: 61.84 03/21/9C 11:37 CHECK 61.84 Payment Method: CHECK Notation: UNION '['Ala WORDS Init: Si4C CHANGE 0.00 ____.._..__.._ ....._..._....._.03 /22.96...123 3939A000 16 :08 CITY OF 1 ►►ti WILA. WA �`I/e .." '. ��r {: "`::.�� . . .. .. �rdsl(tr y •.1•TY• ..1. I�'�Y'ity ��.f Permit Ito: 09G-OO74 Type: 8•-BLDG (BUILDING PERMIT Parcel No; 334740-1330 Site Address: 12065 44 PL S St: 01. Fl: Un: Total Fees: 61.84 This Payment 61.84 Total ALL Pmts: 61..84 Balance: .00 A ***Akit -v*A* *A *AA*a•Akh*k Aft Aft**f t**A.k kA• kd* A *t•kA*AA*A*•A•AAftAtkt•+*•.t *A* Account Code Description Amount 000/322.100 BUILDING - NONRES 34.75 000/345.830 PLAN CHECK •- NONRES 22.59 000/'386.904 STA I E BUILDING SURCHARGE 4.5O COMMENTS: GCi,h �! ■ ,tom ct /_,e Type of inspectio A- 7 _. jU ,�� ���_ Special instructions: U `7 &L r%).--7e„( /,1 s'7 r / 7 _ A , i./ i 5-- .■ Phone No.: ii- h fr-) r-tJ J Project: / , Type of inspectio Address: Date called: Special instructions: Date wanted: / (o / 1-97 a.m. p.m. Requester: Phone No.: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. INSPECTION RECORD Retain a copy with permit Inspector:[/ /I ,�, Date: /, —/2 »: 'h Corrections required prior to approval. $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: PERMIT NO. (206) 431 -3670 llnion.Tark4V tics 1 2065 .4 4't h' Place'. Soutf i P O eok 78069;--1 _: 4, Seance, WA' 98178-0069 - r4S7FNER scy#bvu4 QTY real R1SERS - /? Tv i sic r/fehoS = iv I Li F:i;re Escape Imp'ro,�emen't 2. 3. / L x 6 So / S T RAWER //s x • LAG SUc'Eh/S s7?vci g ib�E /60 GALv A,44/L BDGf}Lv NArt.. Tfestarp LdMQEIQ _:GATE 01Mar96 c on/n/04 -non/ DEe4 PECA Fit 4lW DECK To Ex /ST" 44.44L1- QE44 To rid /b'4 'SIe , ,PE4/'1 To 1)44 s?/PvGT Co.VAJ e rw'), ' of 2 A-694.43 or_R )b,NT PE c# t NG 41 TR E4D CaMMvEC.T1.N, m/ A1 2 PEA TT. Au. srleva7 AAA" , tE J /146 FROM 7 E47Ep 4.4- etaCie FILE SHT _ OF • P// cJ� Q \/ ,, / ,: •••,.. 1' : • c 1 AV E, 5C tifr-et-Gr_ t7.= • 5.r.v rr...N4 cc L'''' •'. i ,>• . ' 7. •',./.../ 7 ..." . .. ...:''' / '''.' . ••' / / .• / -.-..— . ., • . / • ' ./ \ ... ./ ,--, / . •• / / ,, ,/ 4, / / AVE. 50. SC8. 54. MAIN SC' r CorIZ 1 9(^<1 Jo tro 50' 4 5 - 7 SL10 o \ \. ,, Try 7 rF t.-- f l u"7. -D vvo..A MAR 21 1996 PERMIT CENTER lo7AL RISE MAR 2 1 1996 ; EriMIT cEN rEn za" 36 " I II I II I I I I )I - �- - - PIER I& XL . w Posr BA56 (Z 7YP) x6 4"x 4 1I Senm 2. 8'I lowST (3 rep) Ft/i6 ESC A PE -- PI.AV 1/1 6611 E+--- // a -►t FIRE ESCAPE - FL- vAT lo1.l VIFt4/ ex rt." S7R,NGER (3 nYP) 2" x6" TREAD /55" 7o7R L R W • ©I 4' x4-" StAM (2T(P) / LOCATED ON #8 TREAD FROM foP LAND PIER ISI.oGk c z Ty p) 1 3c i 1" BALUSTER 1 I t1(51riNc? BUILDIAl& w/ $- 36" 1 I I I I I I I I AR 6 es‘Hee PLAN vi E34/ 4:x t" Beilm Z S YotS1 (3 TYP) IX 17. STR INGER R (3 fl /35" TOTAL Atm) 2)c (9 MO: INC* POSikU•to C O VbIte 6. S 71/ 3L _3 S S I 13 BALUSTER r..��iT': r;,Y3� GSA ',XfIM7.f ✓f;e:er..!!ryclh Jan 28, 1997 WILLIAM O'CONNELL PO BOX 941 BELLEVUE WA 98009 RE: UNION TANK WORKS Dear Permit Holder: Sincerely, LiZeicti * Kelcie J. Peterson Permit Coordinator Department of Community Development :'Y::L•A, kMSkMM". �W' f555t h+ 4vxvi«., �rm�a.. n. a- w �+ w oval .nnY�M..Yn.vvfrt.�rUtar.+ftatlC. M.1.�R'ISOR:YS1.19.11!+t�nt. <»M HLE Copy City of Tukwila John W. Rants, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • (206) 431-3670 • Fax (206) 4313665 Our records indicate that on Oct 23, 1996, one hundred and eighty days will have passed with no inspections having been called for under Tukwila Building Permit Number B96- 007 Unless you call for an inspection, or obtain a written extension from the Tukwila Building Official prior to that date, your above referenced permit will become null and void on Oct 23, 1996. If your project has been completed please call for final. If you are actively working on it please notify our office. If you have any questions or need further information to obtain an extension on your permit, please call the Tukwila Building Divison at 431 -3670. AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION STATE OF WASHINGTON ) ) ss. COUNTY OF KING ) Union Tank Works , In,cstates as follows: 1. I have made application for a building permit from the City of Tukwila, Washington. 2. I understand that state law requires that all building construction contractors be registered with the State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the Revised Code of Washington, a copy of which is printed on the reverse side of this Affidavit. I have read or am familiar with RCW 18.27.090. 3. I understand that prior to issuance of a building permit for work which is to be done by any contractor, the City of Tukwila must verify either that the contractor is registered by the State of Washington, or that one of the exemptions stated under RCW 18.27.090 applies. 4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby attest that after reading the exemptions from the registration requirement of RCW 18.27.090, I consider the work authorized under this building permit to be exempt under No. 1 , and will therefore not be performed by a registered contractor. I understand that I may be waiving certain rights that I might otherwise have under state law in any decision to engage an unregistered contractor to perform construction work. " %\%,'s•`' APPLICANT Will Unio 7 iam L. O'Connell, 4th n Tank Works, Inc. Signed . d sworn „'4 day of My commission expires: efore me this NOT IC in and fo Washington, siding at e of County. . r .; CITY .,VILA MAR 2 1 1996 PERMIT CENTER 18.27.090 Exemptions. This chapter snail not apply lo: 1. An authorized representative of the United States Government, the State of Washington, or any incorporated city, tuwn, county, township, irrigation district, reclamation district, or other municipal or political corporation or subdivision of this state; 2. Officers of a court when they are acting within the scope of their office; 3. Public utilities operating under the regulations of the utilities and transportation commission in construction, maintenance, or development work incidental to their own business; 4. Any construction, repair, or operation incidental to the discovering or producing of petroleum or gas, or the drilling, testing, abandoning, or other operation of any petroleum or gas well or any surface or underground mine or mineral deposit when performed by an owner or lessee; 5. The sale or installation of any finished products, materials, or articles of merchandise which are not actually fabricated into and do not become a permanent fixed part of a structure; 6. Any construction, alteration, improvement, or repair of personal property, except this chapter shall apply to all mobile /manufactured housing. A mobile /manufactured home may be installed, set up, or repaired by the registered or legal owner, by a contractor licensed under this chapter, or by a mobile /manufactured home retail dealer or manufacturer licensed under chapter 46.70 RCW; 7. Any construction, alteration, improvement, or repair carried on within the limits and boundaries of any site or reservation under the legal jurisdiction of the federal government; 8. Any person who only furnished materials, supplies, or equipment without fabricating them into, or consuming them in the performance of, the work of the contractor; 9. Any work or operation on one undertaking or project by one or more contracts, the aggregate contract price of which for labor and materials and all other items is less than $500, such work, or operations being considered as of a casual, minor, or inconsequential nature. The exemption prescribed in this subsection does not apply in any instance wherein the work or construction is only a part of a larger or major operation, whether undertaken by the same or a different contractor, or in which a division of the operation is made into contracts of amounts less than $500 for the purpose of evasion of this chapter or otherwise. The exemption prescribed in this subsection does not apply to a person who advertises or puts out any sign or card or other device which might indicate to the public that he is a contractor, or that he is qualified to engage in the business of contractor; 10. Any construction or operation incidental to the construction and repair of irrigation and drainage ditches of regularly constituted irrigation districts or reclamation districts; or to farming, dairying, agriculture, viticulture, horticulture, or stock or poultry raising; or to clearing or other work upon land in rural districts for fire prevention purposes; except when any of the above work is performed by a registered contractor; 11. An owner who contracts for a project with a registered contractor; 12. Any person working on his own property, whether occupied by him or not, and any person working on his residence, whether owned by him or not but this exemption shall not apply to any person otherwise covered by this chapter who constructs an improvement on his own property with the intention and for the purpose of selling the improved property; 13. Owners of commercial properties who use their own employees to do maintenance, repair, and alteration work in or upon their own properties; 14. A licensed architect or civil or professional engineer acting solely in his professional capacity, an electrician licensed under the laws of the state of Washington, or a plumber licensed under the laws of the state of Washington while operating within the boundaries of such political subdivision. The exemption provided in this subsection is applicable only when the licensee is operating within the scope of his licens; 15. Any person who engages in the activities herein regulated as an employee of a registered contractor with wages as his sole compensation; 16. Contractors on highway projects who have been prequalified as required by chapter 13 of the Laws of 1961, RCW 47.28.070 with the department of transportation to perform highway construction, reconstruction, or mainteir nce work,