Loading...
HomeMy WebLinkAboutPermit B96-0087 - BANK PLUS MORTGAGE - INTERIORCity of Tukwila (-` (206) 431-3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 BUILDING PERMIT Permit No: B96 -0087 Type: B -BLDG Category: ACOM Address: 5200 SOUTHCENTER BL Location: Parcel #: 115720 -0013 Zoning: C2 PO Type Const: V 1 HR Gas /Elec: Wetlands: Water: N/A Contractor License No.: TRANSCD088MG Status: ISSUED Issued: 04/19/1996 Expires: 10/16/1996 Type of Occupancy: OFFICE Slopes: Y Sewer: N/A TENANT BANK PLUS MORTGAGE 5200 SOUTHCENTER BL, TUKWILA,.WA 98188 OWNER PARKSIDE BUILDING. Phone: (206) 624 -8200 C/O COLLIERS RE .SERVICES, 800 FIFTH AVE STE 3930, SEATTLE WA 981 CONTACT MEL MAERTZ Phone: 206 670 -6706 22000 64TH AVE W, SUITE 2F, MOUNTLAKE TERRACE, WA 98043 CONTRACTOR TRANS CASCADE .DEVELOPMENT `INC. Phone: 206 242 -6785 P.O., BOX 58206, SEATTLE, WA 98138 *'***' k *** * * *k * ** *kk*** * ** * * * * * *•k•k ** * *' *** *•k•k•kk•kk•k• *** *•k•k'k'k•k*** * * * * * *k * **k** Permit Description:; INTERIOR REMODEL. SETBACKS Units: 001 Front: .0 Back: .0 Buildings: 001 Left: .0 Right: .0 Fire Protection: SPRINKLERED UBC Edition: 1994 Valuation: 23,000.00 Total Permit Fee: 540.34 * * * * ** k * * * *:* ** k *•k * * * * ** k * ** *•k * * ** * * * * * * ** * * *'k * *•k*** k* * * * * ** * * **•k *k* * ** *•k ** 'r -- 1-4- I. -ct_Lo Permit Center Authorized Signature Date I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this'work will be complied with, whether specified herein or not. The granting of this. permit does not presume to give authority to violate or cancel the•prov.isions of. any other state or local.laws regulating construction,or,the performance of work. I am authorized to sign for and obtain this bLilding emit. Signature:_ - g1`' Date: Print Name : � `2L _ Title: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. 7/ 4)1 u. ot -tv,: 7 T4M ° D :a E PART 1 f 7 ; 1 r y :, +� lr ,.4. �!� :,a t �,,., > + - $, S � Ax . *WA 1 iF Y L DATE • `' f ' r , A ; P ., : P R;O V,E D :,. _ ,; :, �,,tix:,4,2q, nz= .:,_,.. ,_t , ".. * +, v . f r r " ^ '' .;, ; �; r° +' -t IRE Q ,UIREMENT8.; COMMENT, x -,. .,+ �": irw, ,,, ,,, ,, ,,.. ., ....,? �. , >:y�. , .;�,;..;,, „ - r;Fr 3iY } 3j"u 5 ' t � , r ? ; ;.f. a , 4 A ..i7 X Plan Review Meeting Li` LI -q c0 0(("/-'" 1- i'C .- ` 1 Date Sent - Date Approved - BY: (init.) INIT: ( P 1 Ae )CONSULTANT: 7ED g BUILDING - initial review ck FIRE L)1 /o/ cj�, FIREPROTECTION: Sprinklers 0 Detectors ON/A - IREDEPT. LETTER DATED: y / icy f C U INSPECTOR: / / NIT: 7�7 �""� :AR /LANDUSECONDITIONS? °Yes 0 N O PLANNING ,U A l'\' Ci 1?ONING: IEFERENCE FILE NOS.: INIT: MINIMUMSETBACKS: N- S- E- W- PUBLIC WORKS Otq JS JTILITYPERMITSREQUIRED? OYes ONO PUBLICWORKSLETTERDATED: - - INIT , U ) a , (l t7-U AL C "0 / -IP BUILDING - final review rAri TYPEOFCONSTRUCTION: --- 4 Nk CERT.OF000UPANCY? Oyes 2 N = EDITION t (year ): '- et `t r NI :J t.. 0-( BUILDING OFFICIAL I lb ' (,, / " ' y I IT: ,- , AMOUNT OWING: 4 al ..(a5 CONTACTED i ,., rn�. (}C 1 f 1 �" (Rc DATE NOTIFIED �_ I (0— q q - 'B .: 15 (init.) 2nd NOTIFICATION BY: (init.) 3RD NOTIFICATION 3RD BY: PLAN CHECK NUMBER CITY OF TUKWILA Department of Com)r/unity Development — Permit Center 6300 Southcenter Boulevard - #100, Tukwila, WA 98188 (206) 431 -3670 Building Permit Application Tracking PROJECT NAME 6■941t< Plug for +3 ITE NO. (.00 SITE ADDRESS INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that the status of the project may be ascertained at any time. • Plan corrections shall be completed and approved prior to sending to the next department. • Any conditions or requirements for the permit shall be noted in the Sierra system or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N/A ", date and initial. DEPARTMENTAL REVIEW "X" in box indicates which departments need to review the project. REVIEW COMPLETED 02/15/96 SITE ADDRESS SUITE # g(Pc) ATI.4C61itsi 1 D . 24'0 VALUE OF CONSTRUCTION - $ 23,0c Z • DO PROJECT NAME/TENANT t: putts N(o(Zt e ASSESSOR ACCOUNT # t 15 -120 - 0013 TYPE OF U New Building U Addition Tenant Improvement (commercial) U Demolition (building) WORK: 0 Rack Storage 0 Reroof Remodel (residential) 0 Other DESCRIBE WORK TO BE DONE: I IJ.T62t0 g MC`pb1. BUILDING USE (office, warehouse, etc.) OFF-- G6 NATURE OF BUSINESS: WILL THERE BE A CHANGE IN USE? 'No 0 Yes If Yes, new building requirements may need to be met. Please explain: SQUARE FOOTAGE - Building: Tenant Space: Area of Construction: 4 r 2g60 S.F W LL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING? ( No 0 Yes IF YES, EXPLAIN: FIRE PROTECTION FEATURES: 0 Sprinklers 0 Automatic Fire Alarm System - T\ k\C, PROPERTY OWNER A.511 az GA, COUlA PHONE (ZOCfl) 22 -004 ADDRESS az.7 Fit: - I - }} 4-V. suave 3cto S 64-1 -- \ -- 1 . ,6 - ZIP cle CONTRACTOR --c . 1 776 7- 61 2m i1A.6t . ) PHONE ADDRESS ZIP WA. ST. CONTRACTOR'S LICENSE # EXP. DATE ARCHITECT cot,iLkeu, 1 �Cz�P (c � C� � P HONE (Zo62) (0`70- (c`1D0 ADDRESS 2200 2.1- 7 6.,j S urcb Z F — ZIP Qs CITY OF TUKWILA Department of Community Development - Building Division 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 PLAN CHECK NUMBER APPLICATION MUST BE FILLED OUT COMPLETELY BUILDIN PERMIT APPLICATION BUILDING SURCHARGE DESCRIPTION BUILDING PERMIT: FEE:`:: PLAN CHECK FEE:: >. AMOUNT RCPT .# OTHER::: `TOTAL DATE I`HEREBY:CERTIFY;:THAT: HAVE:. READ AND EXAMINED:THIS AND KNOW THE;SAME;T BE ;TRUE AND;: CORRECT,:: AND I;AM :'AUTHORIZED TOAPPL.Y :F.OR THIS;:PERMIT i BUILDING OWNER SIGNATURE, OR PRINT NAMEMeL, A. MAE AGENT ADDRESS CD & CITY/ZIP CONTACT PERSON �,.- -� PHONE X11 �1�� /?'1,y �4 -� 0570 <- 67"),C, APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. Handouts are available at the Building counter which provide more detailed information on application and plan submittal requirements. Application and plans must be complete in order to be accepted for plan review. VALUATION OF CONSTRUCTION Valuation for new construction and additions are calculated by the Department of Community Development prior to application submittal. Contact the Permit Coordinator at 431 -3670 prior to submitting application. In all cases, a valuation amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Building Division to comply with current fee schedules. BUILDING OWNER / AUTHORIZED AGENT If the applicant is other than the owner, registered archilect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitations. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Building Code (current edition). No application shall Ile extended more than once. If you have any questions about our process or plan submittal requirements, please contact the Department of Community Development Building Division at 431 -3670. DATE " n, / PHONE0o DATE APPLICATION ACCEPTED " �1 - SLID DATE APPLICATION EXPIRES I - ( -4 (() 16,22103 COMMERCIAL NOTE See utility permit application and checklist for specific utility submittal requirements . : . RACK STORAGE ■••■•••■•■•• COrnplete61 building permit aplicaion : • : • • .• " ' • ":•.:::::TWo (2) sets of plans which Include " • •.•••::: • • : Building floor plan shOwing;. • Entire space where racks will be located Exit doors • Dimer.sions of all aisles ' .::'• .• : • Torant space floor plan showing rack storage layout, .. NOTE Includ dim of racks (height width and length) aisles and exit w ay s on plan: ' Structural calculations stamped by a.V'■/ashingtenStetelieeriel,j.,i::: engineai (rack storage 6 and over) RESIDENTIAL . • • • . „. :" • :•' • • • ; :•.. " . • • ••• • • • NEW .SINGLE-FAMILY • DWELLINGS/AIIIDMONS;: ..... •; •••• • • •::•••• ." • Completed building permit application'(aine•fOr'each'struCture):.::: •:Lj Legal description • ::•"•••••••••••••••••••••:::•••• : '. . ..:: ::': :•:. .;.:::: i .,.......... : ,.... ; ...::.......:,........,;„.:: I ........... ;:.: , ..:,:;,;........ : ... ; .., ' . ' •• :: • • . • : Two sets (2) of working •• : : :.*: ..*:*, ii : ::....• ....•:-•:••.:.•••*L.H.: ....:;;,,„:.-..,s:.:t.../;ci;arrr $2r-;sii°i'-:•'•'F.. • . '...::::. •• . • :•.• : ...• • .••••:-... ' '• ' • :{ (o pian, arnoT .-..--. building ;oiciiing,.;:; : ':: - . • Site plan •••7• ......./ I ncl u de access to b • ,.:„.....,..i... Foundation plan ... . ::widthao - • Floor plan • . . . • ......: . . 1 Roof plan Building elevations (all vieWs) .,:::::...-...:.:•::. ••••:::::::•:„:.::::::.::,......::::::::::: : • : • •:Building crosS-sectiOn: : • .......-: ........ •:-..........:•.... ; ;;. ;;.,.: - • . ' ' '..........:',.. : • • • .': • Structural framing plans . : .: .... ; : ..:. ...::............. ; .. 111*■•■■•■ : • • : • : •••:.• ;Washington Sta Energy Code data ; . .• • F Completed utility permit application SUBAITTAL CHECKLAST . . Six (6) sets of site plans showing 'utilities • : • . • . • • . : NOTE: Building site plan and utility site plan may be combineci .. See utility permit application and checklist for specific submittal requirement Additional topographical and soils information May be required if unique site conditions. ..... .. ..... . . . .. .... . . . • comm qRpio.:::*EtpkriTImi500,04ErS, • Wiiontiii**:44 • • 1 1 1 Assessor Accolint Number . • ' .• • : • ••.:: • • .• : ••.: w (2) sets of construction:Plani,...which ineludet'..•••:: • I I Site plan •... . ...„ . c • Locatio of tenant space • Existing end proposed parking • Landscape plan (if applicable, i change Of use • r a r 0 II building plan ... ,‘ • • v . 0 . . . .• : : • , : . • . : : : : . ' • • • • . E4beonnts.; ns of :*••'::overall.dinierisio t foota ...... • •: . .„...., ... . . (common wall) tenant • .:;;••.:,...,:::::•;...„.; . building Or square Froo(pIFM: proposed sPaea . . • Tenant space use of each room labelled td ... : H.:: : .: :::: : deors;:egress'patter • New walls, be :,: existing wall, n and walls to demolished details s et Construction . . 5 ::. Cross sections showing wall Conetru Ion and method of for floor and ceiling Structural Ca ;.::.. ...• • : : ,. .::: ::;:::::.:•:::::: :::— • ' : .:::.':' ':::':L.:: • • attachment calculations engineer may r _ b y a a be done W hington State licensed be required if.structura ! wci is to e ( 2 sets) NOT4';:: if any utility wni.k ia 1 be done, su s utility 1 application and plani.:i:::: :••••••' • • .,..„.. 1 .1gROOF : : : : : • . , • . ; • : : : • : • : • „ : • „ „ : ; . . . Completed buildng•permIt application (one for each structure) : • : Assessor Account :•:.• ::;: .• • Narrative describing existing roof material being removed, and : material being H • . . installed.:'..: ••-.NOTE:.:A certification letter is required prior to final inspection and sign- . offof the pormst. , . • : . • . • .... • .. • .. . . . . ANTENNA/SATELLITE In Completed building permit application . . ; • [1 Assessor Account Number:: Two (2) sets of plans, which • • : • : Site Plan (showing building and location of antenna/satellite dish): Details antenna/satellite.dish and method of .. „ . .5. . . .. ,.....„„.. attachment „...... Structural calculations stamped by a NVashington:State•licerised.:::::: . .„ engineer may be .required :„:: . • : .• : •.: . „ : RESIDENTIAL REMODELS:: '''•:••• • ” • s• • • : • • ".. . . ....ri ...Completed.building permit application (one for each : • • •• :: • • • .• . • .•:: • . • . .. • : Assessor • Tirei:•(0 sets of working drawings which • include • • : . plan • • ; • I • : • : ::••• : ndation plan 'Floor plan Roof plan • Building elevations (all views) • Building cross section Structural framing plans .... ..... . ... . .. . . . NOTE;ifenk:utility..WOrk is to bii.donepro‘dde:Utilitkeermit#Olication::::::. and plans must be Completed blinding Pr:artnit application (onelforeachitrlictUre) : .AsiessorACCount Number • ; . . . • • •• • • •••• • : • • Narrative describing existing roof, material being removed, and : •:. material being ...NOTE: A certification letter is required prior to final Inspection and sign off of the permit.. AddreSs: 5200 SOUTNCENTEP 13L Suite: 260 Tenant: BANK PLUS MORTGAGE Type: B-4/LDG Parcel #: 115720-0013 CITY OF TUKWILA CI Permit No: B96-00B Status: ISSUED Applied: 04104/1996 Issued: 04/19/1996 **44.4***4**4***44.0e4:444(4*IrkWkAlikik*A-4.**44-44 Permit. Conditions: 1. No changes will be made to the plans unless approved by the Architect or Engineer and_the,j0;wi Division. 2, Electrical permits spiall'Ilae!.;6btatned the Washington State Division of IndustrieS work will be ins by that. agency (248 .:. All mechanicaf'W6k,silaJV:ibe jindeseparate par:Mtt issued I oy the City of TUIil:, '':;. ` '' ,-:= ',':'::' '' --; 4. All perSi./ins'gack appl-oved„...01ans be availaD1 lob siteo0i)Or t — the_::tart'of any v00-7- struct104 jhasedocuicientsai be maintained.:and ayall- able qtill 'final inspection 'approval is granted:,, 5. Any am46sed insulations;.b*king -Material shalkhavan,affaMe spr001Ra:Ong of 25 of and/Material shalI fict:ffon"Shgwing the ,.Ore performance rating thereOfY 6. AlTPOnStrUFti.,On to be done in conformance with approved PlOi". a'40;,,7ed.Oirement'S,"of.--the UnifoirmBuilding Code (1994 '.:.......,.., Ed*tiion) aS aMendpdTUntfomAlechaniCai — Code (1994 a944WashingtOn State Eneg. Coda;'1099■4EdItion). , 7, Villdttv , 11 Oal "The AS:suCecii.a per',mit or ap ,, ..* , pl'els, spactficatiOns4 andompOjtatronsshall not be con- Oiled:4 0 baa'ilr_mi-t an abbrOval: asp' VloTatisbn"--' 4 t' . 1 ',...,kt..,2,, 1 '' OilijPY o -t,t.1 Di ov 1 - ' 'i: 'yt tht 13 01 1 : 14 4 code or of:. aPY''-,il, otOar qrtliiIa4pe of'vitireP4itrisdl prasuminq t0' g i IWiatiltijoiii ttri to v i o late or citiCe.j.-'t,ha s i oils, oCt hi coda A;:,.. ha 11( be 'y Li I i d . .,.. , . . : ` a' �. \' : aye• N, A A *A* ** * * * * k •kf * * * * ***A A•A *A kA * *.A * * * *:1•+•• *. *A *A k ** * *A;►AA• *A:A'A*0 *A* k'• CITY OF TUKWILA. WA �31PkAc)ak - TRANSMIT A **o►•A *A *AAAA•AAA *A *A•A ** * A * * **AA *•bA •A*AA' * *AA* * *kA *'A *A* TRANSMIT Number: 96003925 Amount: 211.09 04/04/LW041T15 23 Payment Method: CHECK Notation: CONNELL DESIGN Irsit: GI..f Permit No: B96-0087 Type: G- t11DG BUI:LDT.i1t PEPMI:1' Parcel ido: "115720• -0013 Site Address: 5200 S0U1 UCENTE.R 13L Total Fees: 211..09 Total ALL Pmts: Balance: This Payment 540.34 211.09 329.25 A * *A A* ***•A * * * *A AAA *A•4AA *SEA *A A A *A * *AA**A *AAAA4 * **AAA•AA * *A *k:t *A *A Account Code Dcecrintion Amount 000/345.830 • PLAN CHECK - NC1NFE 3 2.11.09 k *:4.4:1 k h:t kkk ** A * * *.r:. * *1 * *:1y k;E*!•r *A *:kA kkhk*A*A * **k k•A *** kkA 4 *A CITY OF TUItWIL4i. WA (�- r1U:E� 1 f:: +tiE hil l kA *AA*AA *Ak•kA3k *k: s; k* S* ec. * **kAA *A*A *A AAA *AA* *AA *AAA•1A 1RANSMI1 Number: 96004010 Amount: 329.25 04/19/96 0£3:3E' Payment. Method: CHECK: Notation: rRANS CASCADE Init: 5LU Permit rho: 096- -003? Tape: B -BLI)(: BUILDING PERMIT Parcel Na: 115720-0013 S i t e Address: 520() SUUTHCEr4TE'R 131. Fatal Fees. 340.34 1'hi a Payment t 329.25 Total ALL Pmts: 540.34 Balance: .00 * * AAA* AAA** A*• AAA4*A A* d:* A *:AAA *;.A * :\ *AA *A•A :AAAAA A* A'* A•A *A *A *A Account Cods I)e. cri 3t1on Amount 000/322.100 BUILDING - MIRES 324.75 000/386.904 LTArE BUILDING SURCHARGE 4.50 GENERA 211.09 TOTAL 211.09 CHECK 211.09 CHANGE 0.00 4352A000 15 :50 e �h > L I III i4 y mai - pt..vs mormAee Type of inspectio . FINAL I strifiedwr 51... called: 6 - 6 Special instructions: Date wanted: 6_ 30 . 9 ,_ --, „-n. p.m. Requestei coojET Phone No.; 1 L. INSPECTION RECORD I Retain a copy with permit lEplio -c01 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 9818 pproved per applicable cod COMMENTS: Inspector: 1-3670 Corrections required prior to approval. Date: $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: I Date: Project: Type of inspection: p i Address:, bi Date called: S (--5,/g (g Special instructions: 1 s, Date wanted: V % II' • • Requester: , -r61,,,... Phone No.: ,z_4,1 wo tfirayi mastitairk, ft4147,111r."51,A1 I I INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) 431-3670 PERMIT NO. Approved per applicable codes. KCorrections required prior to approval. COMMENTS: iso LP4 ,5;Cli d'7C1 3. fr") Gt./PLO ■-:# (4 — 7//- '_? 1.--21' C2e,k41e / $42.00 REINSPECTIO FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. • I Receipt No.: Date: Past,� FL morZ 06 TYpe� inspec i� 7rotuAlo g dr �`�I la�E� Date calle - r _ clio ( p Special instructions: Date wanted{- m Requester: V ,,\ � �-- Phone No.:/ 0 I 0- 7 6 t) r Approved per applicable codes. COMMENTS: Inspector: a _.L I INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Bcito - m81 PERMIT NO. Date: S / - ' i1 b (206) 431 -3670 Corrections required prior to approval. $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100.E Call to schedule reinspection. Receipt No.: Date: Project: b rtttic. `,n/ U ( u5 imoY Type of inspection: , ,�NY‘(l,,'j Date called: s z _ 1 Address: zrr V -- Special instructions: rte ,r 7j R01,-- Date wanted: S r 3 -< ( a.m. p.m Requester: Phone No.: � r b 1 b 0 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 COMMENTS: Inspector: Approved per applicable codes. Corrections required prior to approval. PERMIT NO. (206) 431 -3670 $42.00 REINSPECTION E REQUIRED. Prior to inspection, fee must P be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: u wsA �•Ay'KU r.4.... w. rXti,::{ i" A: i' rre '_'R_';2�.x.rsirAt...:rn.�.Y. .�'?'i....wa i�.:�!'.H ?::s. .'�'1n. ,.r.r �f� .. TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Project Name ( 1i4 NIL f/� ,, ' Address S' 2.0 / Retain current inspection schedule Needs shift inspection Approved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: / Authorized Signature Date FINALAPP.FRM T.F.D. Form F.P. 85 John W. Rants, Mayor Thomas P. Keefe, Fire Chief Permit No. i26 Suite # Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 5754439 City of Tukwila Fire Department Review Control #B96 -0037 (511) Dear Sir: Fire Department Thomas P. Keefe, Fire Chief April 10, 1996 Re: Bank Plus Mortgage - 5200 Southcenter Blvd., Suite #260 The attached set of b u i l d i n g plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. The total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 3000 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 10B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (NFPA 10, 3 -1.1) Extinguishers shall be installed on the hangers or in the brackets supplied, mounted in cabinets, or set on shelves (NFPA 10, 1 -6.9), and shall be installed so that the top of the extinguisher is not more than 5 feet above the floor. (NFPA 10, 1 -6.9) Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be identified with a sign stating, "Fire Extinguisher ", with an arrow pointing to the unit. (NFPA 10, 1 -6.3) (UFC Standard 10 -1) Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5) Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the John W. Rants, Mayor Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206) 575-4439 City of Tukwila Fire Department Thomas P. Keefe, Fire Chief Page number 2 company or person performing the service. (NFPA 10, 4 -3, 4 -4 and 4 -4.3) Every six years, dry chemical and halon type fire extinguishers shall be emptied and subjected to the applicable recharge procedures. (NFPA 10, 4 -4.1) If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10A -4 -4) Maintain fire extinguisher coverage throughout. 2. No point in a sprinkiered building may be more than 200 feet from an exit, measured along the path of travel. (UBC 1003.4) Aisles leading to required exits shall be provided from all portions of buildings. Aisles located within an accessible route of travel shall also comply with the Building Code requirements for accessibility. (UFC 1204.1) 3. Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 1207.3) Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. 4. When two or more exits from a story are required, exit signs shall be installed at the required exits and where otherwise necessary to clearly indicate the direction of egress. (UBC 1013.1) When two or more exits from a story are required and when two or more exits from a room or an area are John W. Rants, Mayor Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 5754439 City of Tukwila Fire Department Thomas P. Keefe, Fire Chief Page number 3 required by U.B.C. Section 3303, exit signs shall be illuminated. (UBC 1013.3) 5. Maintain sprinkler coverage per N.F.P.A. 13. Addition /relocation of walls, closets or partitions may require relocating and /or adding sprinkler heads. Sprinkler protection shall be extended to all areas where required, including all enclosed areas, below obstructions and under overhangs greater than four feet wide. (NFPA 13 -4- 4.1.3.2.1) 6. All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recognized by The City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1742) All sprinkler system plans, calculations and the contractors Materials and Test Certificates submitted to The Tukwila Fire Prevention Bureau must be stamped with the appropriate level of competency seal. (WAC 212 -80) 7. All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 8. When walls and ceilings are required to be of fire resistive or noncombustible construction, interior finish materials shall meet the requirements of Uniform Building Code 803. The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed John W. Rants, Mayor Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 575-4439 Page number 4 that set forth in Table No. 8 -B of The Uniform Building Code. (UBC 804.1) 9. In order to provide you with the fastest police and fire protection under emergency conditions, please post your suite, room or apartment number in a conspicuous place near the main entry door. Numbers shall contrast with their background. (UFC 901.4.4) Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1742) Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Yours truly, The Tukwila Fire Prevention Bureau cc: TFD file ncd /441 John W. Rants, Mayor Thomas P. Keefe, Fire Chief Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 5754439 04/18/1996 20:28 2062425775 . • ...wear ✓M •a.j 1 • •SrATTLP V•A ' $I38 =1206 • • SIGNATWIE LSsuao Sv DEPARTMENT OF LABOR AND INDUSTRIES PAGE 01 r A a CONTRACT THIS 'SPACE I X l I - :\,,-'\_11.1 1l 1 L I � a T k itflAW‘ Ai in e rag° et Track 2 of Preak•als Garden Tracre• at Per P. •n °ra.. !nv °"""' .s. . °. P r ceJd•J °unJnr °M.ereJln 110 !c I]d lxrcl 9 n. Gc ••J r eh•t rtarn nl Vl i J 1 Jl y ib. S A e ° BP ne 'e• 1•. yr r°. . r1 Y Or cn °. y, ° °PnvY r hY °eNliene Y lP• d VICINITY MAP. I PP Jlts d� x 11•aP Ala .1: 11nr l °n .. d x o. ° n c. x°reM Mn• ! . ly petnt ° ;P: I rnr a lr,nf m M,: r.M yt;rt Len a 1 J.a mrrnut WIT'S 1 ! 1 P r°vld� by cralnrn LT e x•• ' city et yaw., caw el e - 1 !l a•Ae° res 1.447.4.la nn JJItl ' I x..n v In NI* .City e! Tuk e° " J kl n9 ewe•. °X GENERAL NOTES ALL CONSTRUCTION SHALL COMPLY WITH THE 1994 UNIFORM BUILDING CODE, WASHI- NGTON STATE REGULATION FOR BARRIER FREE DESIGN. AMERICANS WITH DISABI- USES ACT, WASHINGTON STATE ENERGY CODE, UNIFORM PLUMBING CODE, AND ALL APPLICABLE LOCAL CODES, ORDINANCES, AND STANDARDS. 2 CONTRACTOR IS TO VERIFY ALL EXISTING CONDITIONS, DIMENSIONS. DETAILS, ETC., AND NOTIFY THE DESIGNER OF ANY AND ALL DISCREPANCIES PRIOR TO PROCE- EDING WITH THE WORK 3. CONTRACTOR SHALL VERIFY ALL 'BUILDING STANDARDS' WITH BUILDING LANDLORD PRIOR TO BEGINNING ANY WORK HOWEVER THERE SHALL BE NO DEVIATIONS WHATSOEVER FROM THE CONTRACT DOCUMENTS WITHOUT THE DESIGNERS WRIT- TEN APPROVAL THEREOF. THE CONTRACTOR AGREES TO DEFEND, INDEMNIFY, AND HOLD THE DESIGNER HARMLESS FROM ANY CLAIMS ARISING AS A RESULT OF UNAPPROVED CHANGES. 4. ALL DEBRIS SHALL BE REMOVED FROM THE PREMISES AND ALL AREAS SHALL BE LEFT IN A CLEAN (BROOM) CONDITION AT AU. TIMES. 5. APPROVED PLANS SHALL KEPT IN A PLAN BOX AND SHALL NOT BE USED BY ANY WORKMEN: ALL CONSTRUCRON SETS SHALL REFLECT THE SAME INFORMATION AS WELL AS AU. REVISIONS. ADDENDA, AND CHANGE ORDERS. THE CONTRACTOR SHALL ALSO MAINTAIN IN GOOD CONDITION, ONE COMPLETE SET OF PLANS WITH ALL REVISIONS, ADDENDA, AND CHANGE ORDERS, ON THE PREMISES AT ALL TIMES WHICH ARE TO BE UNDER THE CARE OF THE JOB SUPERINTENDENT. ALL OPERATIONS CONDUCTED ON THE PREMISES SHALL NOT BE OBJECTIONABLE BEYOND THE PROPERTY BOUNDARY USES BY REASON OF NOISE, STEAM, ODOR, FUMES, GASES, SMOKE, VIBRATION, HAZARD OF OTHER CAUSES. IN ADDITION, THE CONTRACTOR SHALL MINIMIZE DISRUPTIONS OF ADJACENT TENANTS DUE TO NOISE ODOR; CORRIDOR FUMES, OR VIBRATION. AU. COMMON LOBBY AND CORRIDOR SPACE SHALL BE KEPT CLEAR OF 0118T, DEBRIS. AND CONSTRUCTION MATERIALS AT ALL TIMES. 7. ALL WORK SHALL BE APPLIED IN ACCORDANCE WITH THE MANUFACTURER'S LATEST RECOMMENDATIONS OR WRITTEN DIRECTIONS. 0. AU. DIMENSIONS ARE TO FACE OF GYPSUM SALL BOARD UNLESS OTHERWISE NOTED. 9. WHERE CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF THE WORK, THE DETAILS SHALL BE THE SAME AS FOR OTHER SIMILAR WORK IN THE SAME BUILDING.. 10. : WHERE DEVICES OR !TENS OR PARTS THEREOF ARE REFERRED TO IN SINGULAR IT IS INTENDED THAT SUCH SHALL APPLY TO AS MANY SUCH DEVICES. ITEMS OR FARTS AS ARE REQUIRED TO PROPERLY COMPLETE THE WORK. 11, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE AU. EXISTING UTIL EES WHETHER SHOWN HEREON OR NOT AND TO PROTECT THEM FROM DAMAGE. • THE CONTRACTOR SHALL BEAR ALL EXPENSE OF REPAIR OR REPLACEMENT OF , unt.mE6 OR OTHER PROPERTY DAMAGED BY OPERATIONS IN CONDUCTION WITH THE EXECUTION OF HIS WORK 12 THE CONTRACTOR WILL VERIFY AND CONFORM TO ALL REQUIREMENTS OF ALL '( UTILITY COMPANIES UNLESS OTHERWISE NOTED IN THE PLANS AND SPECIFICATIONS. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO ENSURE THE SAFETY OF THE OCCUPANTS AND WORKERS AT ALL TIMES. 14. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE SECURITY OF THE - BUILDING AND SITE WHILE JOB IS IN PROGRESS AND UNTIL THE JOB IS COMPLETED. ALL WORK SHALL BE GUARANTEED FOR A PERIW OF ONE (1) YEAR AFTER ' - COMPLETION, UNLESS OTHERWISE SPECIFIED, AND SHALL BE SO STATED IN CONTRACTOR'S WRITTEN PROPOSAL AND AGREEMENT. AU. REPAIRS, CORRECTIONS, AND DISCREPANCIES, ETC., MUST BE MADE WITHOUT ANY ADOTTONAL COST TO THE OWNER, AND WITHIN FIVE (5) DAYS AFTER NOTICE IS GIVEN. 16. LATHING, PLASTER, AND GYPSUM WALL BOARD SYSTEMS SHALL CONFORM TO THE CHAPTER 470E THE 1994 U.B.C. - . 17. ALL EXPOSED GYPSUM SOARD TO HAVE METAL EDGES AT ALL CORNERS AND WALL INTERSECTIONS. IA. ALL GLASS AND GLAZING SHALL COMPLY WITH CHAPTER 54 OF THE 1994 U.B.C. AND THE U.S. PRODUCT SAFETY COMMISSION: •SAFETY STANDARD FOR ARCHITECTURAL GLAZING MATERIALS. ALL REQUIRED FIRE DOORS SHALL SEAR A LABEL FROM A RECOGNIZED AGENCY SHOWING THE SPECIFIC RATING. EXIT SIGNS AND ILLUMINATION SHALL CONFORM TO THE 1994 U.B.C. CHAPTER 33, AND LOCAL FIRE MARSHAL REQUIREMENTS. - EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. 22 FIRE EXTINGUISHERS: VERIFY REQUIREMENTS AND LOCATIONS WITH FIRE MARSHAL. CONTRACTOR TO SUPPLY FIRE EXTINGUISHERS AND CABINET AS REQUIRED. ELECTRICAL ROUGH -IN MID REFLECTED CEIUNG PLAN ARE FOR THE GENERAL INFORMATION OF THE CONTRACTOR. EXACT LOCATIONS SHOULD BE VERIFIED. FLAMMABLE LIQUIDS SHALL NOT RE PLACED, STORED, OR DISPENSED IN THIS OCCUPANCY EXCEPT AS PROVIDED IN N F PA STANDARD 30 AND THE CURRENT UNIFORM FIRE CODE. PERMIT MAY BE REQUIRED. ALL DRAPES. HANGINGS, AND CURTAINS, DROPS, AND ALL OTHER DECORATIVE MATERIAL INCLUDING CHRISTMAS TREES THAT WOULD TEND TO INCREASE THE FIRE AND PANIC HAZARD SHALL BE MADE FROM NON- FLAMABLE MATERIAL OR SHALL BE TREATED AND MAINTAINED IN A FIRE RETARDANT CONDITION BY MEANS OF A FLAME RETARDANT SOLUTION OR PROCESS APPROVED BY THE COUNTY FIRE MARSHAL PROVIDE A CERTIFICATION TO THIS EFFECT.' A. EXIT DOORS, EXIT UGHTS. AND FIRE EXTINGUISHER LOCATIONS SHALL NOT BE CONCEALED OR OBSTRUCTED BY ANY DECORATIVE MATERIAL B. . MINIMUM FLAME SPREAD CLASSIFICATION OF INTERIOR FINISHERS SHALL BE- - PER TABLE 42 -5 OF THE 1994 U.S.C. 26. ALL LAY -IN ACOUSTICAL CEILING GRIDS SHALL BE INSTALLED AND SECURED PER 1204 U.B.C. SECTION 4704. STANDARD 47 -1S, FOR EARTHQUAKE ZONE III. 27. PROVIDE OR MODIFY AS NEEDED SPRINKLER, ALARM AND SMOKE DETECTION SYSTEM PER ALL APPUCABIE CODES. INCLUDING IF NECESSARY FIRE HORNS, STROBELOHTS, CONTROL PANEL CONNECTIONS SMOKE DETECTORS, AUDIO VISUAL ALARMS. SUBMIT SHOP DRAWINGS TO THE FIRE MARSHALL FOR APPROVAL 25. TENANT TO PROVIDE AND INSTALL THE TELEPHONE MID DATA COMMUNICATION CABUNG. CONTRACTOR TO COORDINATE SCHEDUUNG AND OTHER REQUIREMENTS WITH TENANT. 29. MECHANICAL SYSTEM: CONTRACTOR SHALL VERIFY AND PROVIDE A COMPLETE HVAC SYSTEM WHICH CONFORMS TO THE OWNERS HVAC SPECIFICATIONS. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ROOF PENETRATIONS AND PATCH- ING, ANY SCREENING OF ROOF - MOUNTED MECHANICAL UNIT REWIRED BY GOVERN - INS JURISDICTION. 30. PROVIDE OR MODIFY AS NEEDED EMERGENCY LIGHTING. 31. ALL ITEMS MARKED' N.I.C.' ARE NOT PART OF THIS CONTRACT. 32. ABBREVIATIONS THROUGHOUT THE PLANS ARE ABBREVIATIONS WHICH ARE IN COMMON USE. THE UST OF ABBREVIATIONS PROVIDED IS NOT INTENDED TO Be COMPLETE OR REPRESENTATIVE OF CONDITIONS OR MATERIALS ACTUALLY USED ON THE PROJECT. THE DESIGNER WILL DEFINE THE INTENT OF ANY IN QUESTION. DO NCR, SCALE DRAWDUOS. SCALE NOTED ON PLANS • 19. 20 23 24. 25. ABBREVIATIONS ACOUS. ACT. ADJ. A.P. A PVD. ARCH. BLK. BLDG. CL OR C CLKG. COL. CONC. CONST. CONTR. CPT. C.W. DEPT. OCT. DING. DIA. DIM. DWG. ELEV. ELEC. EQ. EQPT. EXIST. F.I.O. FIN. FL. F.O.I.C. GL. G.W.B. HD. WD HT. H.W. INCD. INCL. INTR. JT. LAM. LTG. LT. ACOUSTIC: ACOUSTICAL ACOUSTICAL TILE ADJUSTABLE: A ACCESS PANEL APPROVED ARCHITECTURAL BLOCK: BLOCKING BUILDING CENTER LINE - CAULKING COLUMN C CONSTRUCTION.: CONTRACTOR CARPET COLD WATER DEPARTMENT DETAIL DIAGONAL DI, AETER DIMENSION DRAWING ELEVATIONIBLDO): ELEVATOR ELECTRICAL MAT. MAX. MFD. MFR. MIN. MISC. MTD. MTL N.I.C. N.T.S. O.C. PT. PART. PL. P.LAM PLY. R.B. REF. REDD. REV. S. SHT. EQUIPMENT SIM. EXISTING - SPEC. FURNISHED B INSTALLED SST. BY OTHER STD. FINISH STOR FLOOR STRUC.. FURNISHED BY OTHER. SUSP. INSTALLED BY - -- SW. CONTRACTOR - TEL GLASS: GLAZING: GLAZED TEMP. GYPSUM WALL BOARD TYP. HARDWOOD HEIGHT HOT WATER VERT. INCLUDE INTERIOR W C. JOINT WD. LAMINATED: LAMINATE WT. LIGHTING LIGHT PROJECT DATA MATERIAL MAXIMUM MANUFACTURED MANUFACTURER MINIMUM MISCELLANEOUS - MOUNTED METAL NOT IN CONTRACT NOT TO SCALE ON CENTER PAINT , PARTITION POLISHED PLATE GLASS PLATE PLASTIC LAMINATE PLYWOOD QUARRY TILE RUBBER BASE REFERENCE REQUIRED REVISED: REVISION ROUGH'OPENIN0 STAIR SECTION SHEET SIMILAR SPECIFICATIONS: SPECIFIED STAINLESS STEEL STANDARD STORAGE STRUCTURAL SUSPEND: SUSPENDED SWITCH TELEPHONE TEMPERED. TYPICAL VARIABLE: VARIES VINYL COMPOSITION TILE VERTICAL: VERTICALLY VENEER PLASTIC W LLCM RING WEIGHT - PROJECT ADDRESS: GOVERNING CODE: USE ZONE: OCCUPANCY: CONSTRUCTION TYPE: ENERGY CODE:. BUILDING CODES CONTRACTOR: MECHANICAL: ELECTRICAL: SPRINKLER SYSTEM: TENANT AREA TOTAL' 5200 SOUTHCENTER BOULEVARD, TUKWILA, WA. 1994 U.B.C. (STATE OF WASHINGTON AMENDMENTS) C -2 b7S SF. 3,286 SF V 1 AR 1994 WASHINGTON STATE ENERGY (`ODE 1554 U.P.C. 1994 U.B.C. TO BE DETERMINED PRIOR TO PERM T ISSUANCE BIDDER DESIGN (UNDER SEPARATE PERMIT) BIDDER DESIGN (UNDER SEPARATE PERMIT) BIDDER DESIGN (UNDER SEPARATE PERMIT) DRAWING INDEX T -1 COVER SHEET Al - DEMOLMONIPARTfTION PLAN , A. REFLEC I tU CEILING PLAN El ELECTRICAL/TELEPHONE PLAN . Nta. e..lchls / / I TUKWI. ( BUILDV^ DIVIS:� NOTE SEPARATE PERMIT REQUIRED FOP: MECHANICAL ELECTRICAL ❑PLUMBING O GAS PIPING CITY OF TUKWILA BUILDING DIVISION 1111 WI) ot 0 p pp\ RECEIVED CITY OF TUKWILA APR 0 4 1996 PERMIT CENTER CDG d el i n 1J<T ` desin - :. gr.ou PLANNING. 67b DESIGN 22000 64TH AVENUE WESTYNDF M„u,.UYI1• rP WA 981143 ?ON 1170'.: I 59 'OUC MAER TT- STATE OF ' A(AShI17TON REVISIONS TITLE COVER SHEET SHEET T- REGISTERED ATONI1'E 12' -A' \H IJ/ 16' -6" DEMOLITION /PARTITION PLAN SCALE: I /S' a I' -0• BREAK ROOM 1 2031 OPEN WOf 1( AREA 12(341 , B%oowi DEMOLISH EXISTING PARTITION 206 RAGE OFFICE OFFICE 1 2051 FrOr,"07," i/A r11�' •! IIIRIIIIIIIIiI r 9191111111W SECOND '1 EVEL FLOOD PL DEMOLITION NOTES DEMOLITION occults, ALL RENAMING WALLS APE TO DE PATCHED, SANDED SMOOTH AND PREPARED FOR FMISWING M REQUIRED. PATCH AND PREPARE FLOORS AS REGUIRED SNOOTHA LEVEL FINISH. ALL EXISTING WALL FINISHES TO DE REMOVED. WALLS ARE TO BE PATCHED, SHADED. EMOOTHAND PREPARED FOR NEW FINISIRS AS RECURRED. WHERE NEW PARTITION MEETS EXCISING ROWED COLUMN OR CORE WALL, REMOVE COINER DEAD, ALIGN, TAPE AND SPACKLE NEW PARTITION TO EXISTING GYPSUM BOARD. ALL CONSTRUCTION TO REMAN AND AFFECTED SY DEMOLITION SHALL BE PATCHED AND SPACKLED AND DE PROPERLY MEMBERED AND ALIGNED SO AS TO LEAVE NO EVIDENCE OF PATCHING OR REPAIRS. EXISTING ELECTRICAL AND TELEPHONE CUTLETS LOCATED ON DEMOLISHED WALLS ARE TO DE REMOVED INCLUDING CONDUIT AND WIRNG BACK To JUNCTION DOX WHERE PLUMBING FIXTURES ARE DENG REMOVED OR WHERE EXPOSED PLLPIDNG PIPES OCCUR CAP LINESDEH1ND FINISHED SURFACES. ALL EXISTING CONSTRUCTION WHERE INDICATED INCLUDING ELECTRICAL, TELEPHONE, PLUIDING AND MECHANICAL DEVICES NOT OTHERWISE INDICATED ON THESE CONSTRUCTION DRAWINGS SHALL GE REMOVED N A CAREFUL MANNER SO AS NOT TO DAMAGE ADJONNG CONSTRUCTION. PARTITION NOTES ALL PARTITIOR UNLESS OTHERWISE NOTED, SHALL ISE CONSTRUCTED WITH METAL. STUDS. AT 24' OZ. WITH SW TYPE 'X' GYPSUM WALLBOARD EACH SIDE. THERE SHALL DENO EXPOSED PIPE, CONDUIT, DUCTS, VENTS, ETC. ALL SUCH LINES SHALL SE CONCEALED OR FURRED AND FINISHED, UNLESS OTHERWISE NOTED AS EXPOSED CONSTRICTION ON DRAWINGS. OFFSET STUDS, WHERE REQUIRED, 80 THAT FINISHED PARTITION SURFACE WILL DE FLUSH, UNLESS OTHERWISE: NOTED. PROVIDE FURRING AT EXISTING PARTITIONS AE RECUIRED. TO INSTALL ELECTRICAL DEMO AS NDICATED ON THE DRAWINGS. DOOR AND CASED OPENINGS WITHOUT LOCATION DIMENSIONS ARE TO DE SIX INCHES FROM FACE AT HINGE SIDE OF DOOR TO ADJACENT PARTITION. ALL ANY E DO R S 544AL O E FROM THE Neva WITHOUT USE OF KEY OR PROVIDE SHEET METAL RER:F'ORCING (S' HORIZONTALLY MOULTED STRIP OP 20 GA GALVANIZED SHEET METAL/ N PARTITIONS FOR INSTALLATION Of WALL HUNG CADRET WORK AND PANELING WHERE INDICATED ON DRAWINGS INCLUDED ALL OWNER PROVIDED ITEMS. CONTRACTOR TO VERIFY DIMENSIONS FOR ALL PLUMBING PARTITIONS. CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR DESIGNER APPROVAL PRIOR TO MANUFACTURE OF ANY CABINET WORK, MILLWORK. AND ANY OTHER SPECIAL ITEMS REGUIRNG CUSTOM SHOP FABRICATED WORK. PARTITION LEGEND EXISTING PARTITION TO REMAIN EXISTING PARTITION TO REMAIN D/S TENANT PARTITION - IS/8 METAL STUDS • 24. 0.0 WITH SAY TYPe 'X' GM ON 50TH SIDES FROM FLOOR TO IDERSIDE OF NUF5 CEILING. 5/S SOUND PARTITION - 5/S METAL STUDS • 24' O.C. WITH ER' TYPE GIA5 150TH SIDES AND 2 10' SOUND ISATTS FROM FLOOR TO UNDERSIDE OF CEILING. PROVIDE 4' -0' GATT INSULATION. CENTERED OVER PARTITION ABOVE CEILING. D/S DEMISING PARTITION - DM METAL STUDS • IS' OL. WITH 5/8' TYPE GWD ON 50TH SIDES FROM FLOOR TO UNDERSIDE OF HUM CEILING. PROVIDE INSULATION IN PARTITION WITH 4' -0• BATT INSULATION CENTERD OVER PARTITION ABOVE CEILING _==== UPGRADE EXISTING PARTITION TO D/S DEMISING WALL. D/B 2' -0' RI PARTIAL HIEICWNT RECITE IN B/S FRAME. SILL AT 3' -0' APP. D/S 3' -0• w PARTIAL HEIGHT RELITE N Bb FRAME. SILL AT 3' -0• APP. 2' -O" w FULL HEIGHT 48 MN. RATED GLASS RELITE N RATED FRAME 80EMDLY. � D/S 4' -0" w PARTIAL HEIGHT RELITE N B/e FRAME. SILL AT V.O. APP. KEYNOTES I. ALIGN FINISHED SURFACES. 2. CEN?ERLSE OF MULLION/PARTITION. X BM 4' -0" x 4' -0' x 3/4' TREATED PLYWOOD TELEPHONE BOARD. 4. ALIGN WOTH FACE of COLUMN DOOR SCHEDULE DOOR OMER TYPE OF DOOR A. DR 3' -0' x D/6 HEIGHT DOOR IN DR FRAME D. 5/S 3' -0' x15/8 HEIGHT 20 MIN. RATED DOOR EXISTING TO REMAIN WOOFS 4. OR LATCHSET b. DR LOQGSET RECEIVES CITY OF TUK`NIW APR 0 4 1996 PERMIT CENTER CDG design es�gn group PLANNING & DESIGN 22000 64th Ave. W. Suite 2F Mountlake Terrace, WA 98043 (206)670 -6706 FAX (208)774 -8219 REVISION IS 04/0878 ISSUED FOR PERMIT TAE DEMOLITION /PARTITION PLAN, REFLECTED CEILING PLAN %066 Job Etc. Dann By A -1 i?,EU �i1.TECT. LL A. MAERT7 S11)0 OF *OHMIC! e••u SCALE: 1/8" + VACANT SUITE REFLECTED CEILING PLAN ESREAK ROOM OPEN NOR<AREA EEO 12041 I®1•®_ Il►M11 ®■► ®► ® 1 11111111•11111111111111111111111111111111111 '311•11i111=1 _ ®1 $ I!�I�iiii� ®��� ®t_ 111111•►111111111•®■11111 IIIIIMIIME1111111•■111111 IN1111•111111111101 M 1 2001 CONFERENCE RECEPTIONMIAITINCs COPY /5T• RAGE OFFICE 13RbcoZ 7 OFFICE Ira LIGHTING NOTES PROVIDE FIRE DAMPERS AT ALL SUPPLY AND RETURN AIR OUTLETS, INLETS OR DUCT PENETRATING FIRE RATED ASSEMBLIES, ENCLOSURES: WALLS. FLOORS OR SURFACES AND AS REQUIRED EY THE FIRE DEPARTMENT. CONTRACTOR SHALL OBTAIN APPROVAL FROM DESIGNER OF ALL THERMOSTAT LOCATIONS. ALL REQUIRED EXIT SIGNS SHALL HAVE LETTERS SIX INCHES HIGH MMIMUI AND SHALL CQ1FOIEI WITH ALL. APPLICABLE CODES. CEILING HEIGHTS ARE FRDM SLAB TO F5415150 CEILING. LIGHT SWITCHES SHALL BE INSTALLED AT .48" AFF. MULTIPLE SWITCHES SHOULD BE GANGED TOGETHER UNLESS 0T4ER4ISE SPECIFIED. CONTRACTOR SHALL PROVIDE EMERGENCY LIGHTNG, STROBE LIGHTS, AUDIO- VISUAL ALARMS TO MEET ALL APPLICABLE CODES. LIGHTING LEGEND EXISTING B/8 2 x 4 FLUORESCENT LIGHT FIXTURE TO REMAIN ILJ RELOCATED EXISTNG 15/8 2 x 4 FLUORESCENT LIGHT FIXTURE RELOCATED 24 HOUR FIXTURE Al ILLUMINATED EXIT SIGN - DIRECTION OF ARROW aH 5/9 SINGLE SWITCH LIGHTING CALCULATIONS ALL EXISTING LIGHT FIXTURES TO REMAIN WITHIN TENANT SPACE, NO PROPOSED CHANGE IN ENERGY USAGE. FOAM TAPE TRACE AT 2 OL ABOVE AT 8 0 MAX. W/ MTL. STUDS ' GATT INSULATION AT 801150 PARTITION ACOUSTICAL CEILING TILE WrPTA PLEFMWNG TRIM CONT. 1/4" 20 GA TRACK W/ 2 -MO SCREWS AT 24 00. AT�8p T1 D PARTITIOII� AT 24 00 V. Wil. STUD 5/S" TWK N �CCNB ATRIGTIO�N)E CONT. 25 GA. GALV. STL. RUNN R OH N F L AND TO 02 4, SYSTEM ASIAATTD OG O SECTION BUILDING STANDARD PARTITION SCALE: ETA. RECIVED CIfY OF E TUKWIU APR 0 4 1996 PERMIT CENTER cconnell C design group PLANNING & DESIGN 22000 64th Ave. W. Suite 2F Mountlake Terrace, WA .98043 (206)670 -6706 FAX (206)774 -8219 REVISIONS 04401196 188UED FOR PERMIT TITLE or, III III 59H REGISTERED AACHIT MEL A. MAERT STATE OF WASHINGTON REFLECTED CEILING PLAN 96066 Job Flo.: Drawn ay. SHEET A -2